Table of Contents 80 sections PS14P Power Source Switch (PoE) · Magnum S14 Convenient Switch · (Members of the Converter Switches family) · Installation and User Guide · … ShowHide
PS14P Power Source Switch (PoE)p.1Magnum S14 Convenient Switchp.1(Members of the Converter Switches family)p.1Installation and User Guidep.1Magnum ™ S14 & PS14P (PoE) Convenient Switchesp.2Radio Frequency Interference Statementp.3Federal Communications Commissionp.3Email: [email protected]p.447823 Westinghouse Dr. Fremont, CA 94539p.4Phone (510) 438-9071p.4Fax (510) 438-9072p.4Contacting GarrettCom, Incp.45.3 Return Material Authorization (RMA) Procedure Error! Bookmark not definedp.64.3: Dual LEDs, Front-panel and side-panel (S14-Series & PS14P(PoE))62p.63.7 S14H & S14P, DC-powered, Installation ......................................... 52p.63.7.1 Power Requirement for PS14P(PoE) Power Source Switch.......... 54p.63.8 Connecting Twisted Pair (RJ-45 ports).............................................. 55p.63.8.1 Connecting Twisted Pair ( Unshielded or Shielded)................. 56p.63.8.2 Connections to NICs which support Auto-Neg RJ-45 ports...... 57p.64.1 Dual-Speed Functionality, and Switching ......................................... 58p.64.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing................ 60p.65.4 Shipping and Packaging Information................................................. 67p.6APPENDIX A: WARRANTY INFORMATION......................................... 69p.6Revisionsp.61.1 Technical Specificationsp.81.0 SPECIFICATIONSp.8Ports Performancep.8Packet-Processing Between Domainsp.9Packaging:p.11UL listed class II Power Supply, ( AC External):p.12POWER SUPPLY (S14 Model only)p.12Power Supply ( Direct DC ): built-in screw terminalp.13POWER INPUT: (PS14P(POE) unit only)p.13POWER OUTPUT: (PS14P(POE) unit only)p.14LED Indicators (Dualfront and end, port #4 has front only)p.15Mounting option for S14 Family of Switches:p.15Agency Approvals and Standard Compliance:p.16DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one S14-Seriesp.171.2 Summary of models and descriptions:p.17Magnum PS14P (PoE) Power Source Switch (model and descriptions)p.182.0 INTRODUCTIONp.18PORT 1 PORT 2 PORT 3p.21Fig 2.2ap.21LK/ACTp.21POWERp.21LK/ACT 10/100 9VDC. 1AMPp.21PORT 4p.21Fig 2.2dp.23LA3p.23LA2p.23PWRp.23LA1p.23F/Hp.23Fig 2.2cp.23Fig. 2.2ep.242.2.1: Magnum PS14P : 4-port PoE Power Source Switchp.252.3 Magnum PS14P & S14-Series, with four (RJ-45) Copper portsp.312.4 Frame Buffering and Latencyp.32both present. Dual-source power may increase availability, or bep.372.6 Applications (S14 Series and PS14P(POE) Switches)p.38For S14-Seriesp.38F H = Xp.402SWp.40GARRETTp.40PLCp.42Example 3: S14Psp.43Example 4a. Magnum PS14P (Power Source Switch) for PoE device onlyp.45Example 4b. Magnum PS14P (Power Source Switch) for PoE device onlyp.46IBMp.48Secure attachment of mountingp.49clips for Panel-p.493.0 INSTALLATIONp.493.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media Convertersp.51A Magnump.54PS14P(PoE) with -48VDC supply (left) and S14Hp.54(right) is shown alongside the DIN-Rail-MC2p.543.5 Power Requirements, Power Supply Types for S14-Series Switchesp.55bracketp.5512VDC 24VDC -48VDCp.56inputp.57
Page 1 of the GarrettCom PS14P user manual — &
Page 1 · click to enlarge
Page 1
GarrettCom PS14P — PS14P Power Source Switch (PoE) diagram (page 1)
Fig. 1 · PS14P Power Source Switch (PoE)

PS14P Power Source Switch (PoE)

Magnum S14 Convenient Switch

(Members of the Converter Switches family)

Installation and User Guide

GarrettCom PS14P — (Members of the Converter Switches family) diagram (page 1)
Fig. 2 · (Members of the Converter Switches family)

&

GarrettCom PS14P — & diagram (page 1)
Fig. 3
Page 2 of the GarrettCom PS14P user manual — Installation and User Guide
Page 2 · click to enlarge
Page 2

GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch and Converter

Switches contain no user serviceable parts. Attempted service by unauthorized

Copyright © 2005 GarrettCom, Inc. All rights reserved. No part of this publication may

Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.

experienced with Magnum S14 & PS14P 10/100 Mb/s Convenient Switches,

Magnum ™ S14 & PS14P (PoE) Convenient Switches

be reproduced without prior written permission from GarrettCom, Inc.

personnel shall render all warranties null and void. If problems are

Installation and User Guide

consult Section 5, Troubleshooting, of this User Guide.

Part #84-00100 Rev. B (01/06)

NEBS is a registered trademark of Telcordia Technologies

UL is a registered trademark of Underwriters Laboratories

Ethernet is a trademark of Xerox Corporation

Printed in the United States of America.

Trademarks

Page 3 of the GarrettCom PS14P user manual — Radio Frequency Interference Statement
Page 3 · click to enlarge
Page 3

This equipment generates, uses and can radiate frequency energy and if not

installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested and

found to comply with the limits for a Class A computing device in accordance with the

specifications in Subpart J of Part 15 of FCC rules, which are designed to provide

reasonable protection against such interference when operated in a commercial

environment. Operation of this equipment in a residential area is likely to cause

interference, in which case the user at his own expense will be required to take whatever

Radio Frequency Interference Statement

Federal Communications Commission

measures may be required to correct the interference.

Page 4 of the GarrettCom PS14P user manual — Contacting GarrettCom, Inc
Page 4 · click to enlarge
Page 4

Please use the mailing address, phone and fax numbers and email address listed below:

Websitehttp://www.GarrettCom.com

Email: [email protected]

47823 Westinghouse Dr. Fremont, CA 94539

GarrettCom, Inc.

Phone (510) 438-9071

Fax (510) 438-9072

Contacting GarrettCom, Inc

Page 5 of the GarrettCom PS14P user manual — Email: support@garrettcom.com
Page 5 · click to enlarge
Page 5
Page 5 of the GarrettCom PS14P user manual — Email: support@garrettcom.com
Page 6 of the GarrettCom PS14P user manual — Revisions
Page 6 · click to enlarge
Page 6

5.3 Return Material Authorization (RMA) Procedure Error! Bookmark not defined

4.3: Dual LEDs, Front-panel and side-panel (S14-Series & PS14P(PoE))62

3.7 S14H & S14P, DC-powered, Installation ......................................... 52

3.7.1 Power Requirement for PS14P(PoE) Power Source Switch.......... 54

3.8 Connecting Twisted Pair (RJ-45 ports).............................................. 55

3.8.1 Connecting Twisted Pair ( Unshielded or Shielded)................. 56

3.8.2 Connections to NICs which support Auto-Neg RJ-45 ports...... 57

4.0 OPERATION ....................................................................................... 58

4.1 Dual-Speed Functionality, and Switching ......................................... 58

4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing................ 60

5.1 Before Calling for Assistance ............................................................ 64

5.2 When Calling for Assistance ............................................................. 65

5.4 Shipping and Packaging Information................................................. 67

APPENDIX A: WARRANTY INFORMATION......................................... 69

01/06: Updated the PS14P(POE) Power Source Switch Rev B 05/05: Added Magnum PS14P(POE) Power Source Switch

Revisions

Page 7 of the GarrettCom PS14P user manual — 5.3 Return Material Authorization (RMA) Procedure Error! Bookmark not defined
Page 7 · click to enlarge
Page 7

06/04: Small revision of the Agency Approvals Rev A 03/04: Initial release of this user manual for the S14 Converter Switch

GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or

10/04: Small edit and updates on power supply option. 09/04: Small edit and updates on UL.

model offerings without notice.

Page 8 of the GarrettCom PS14P user manual — 1.0 SPECIFICATIONS
Page 8 · click to enlarge
Page 8

Data packets that have the 4-bytes tagged VLAN field (802.1q) inserted in

100Mb: Ethernet IEEE 802.3u, 100BASE-TX, IEEE 802.1p 10 Mb: Ethernet IEEE 802.3, 10BASE-T Power Over Ethernet: IEEE 802.3af (PS14P model only)

them are received and transmitted unchanged.

Data Rate10 Mbps

When a port is operating at 100Mbps:

Auto-sensing for speedIEEE 802.3u

When a port is operating at 10 Mbps:

1.1 Technical Specifications

Data Rate100Mbps

1.0 SPECIFICATIONS

Ports Performance

Network Standards

Page 9 of the GarrettCom PS14P user manual — Packet-Processing Between Domains
Page 9 · click to enlarge
Page 9

Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.

Latency (not including packet time): 100 to 10 Mbps: 5µs 10 to 100Mbps: 5µs Path Delay Value: 50 BT on all ports

Packet buffers memory128KB,dynamically shared on all domains

Filter / Forwarding Rate from 100Mbps ports: 148,800 pps max

10BASE-T (Unshielded twisted pair) - 100 m (328 ft)

Processing typeStore and Forward, non-blocking

100BASE-TX (CAT 5 UTP) - 100 m (328 ft)

Maximum Ethernet Segment (or Domain) Lengths

Address buffer age-out time: 300 sec.

Packet-Processing Between Domains

Auto-learning2K address table

(Non-blocking switching)

Page 10 of the GarrettCom PS14P user manual — Packet-Processing Between Domains
Page 10 · click to enlarge
Page 10

Ambient Temperature (S14): 32ºF to 104ºF (0ºC to 40ºC) (S14H): -13ºF to 140ºF (-25ºC to 60ºC)

-40ºF to 167ºF (-40ºC to 75ºC)

(S14P & PS14P)-40 º F to 185 º F (-40 º C to 85 º C)

-40ºF to 167ºF (-40ºC to 75ºC)

Storage Temperature, All models-40 º F to 185 º F (-40 º C to 85 º C)
Altitude (All models)-200 to 5000ft. (-60 – 15,000 m)
Ambient Relative Humidity5% to 95% (non-condensing)
Cold Start(S14H) model to -20ºC

(S14P) model to -40ºC

Conformal Coating (optional) Humidity protection

Long term per independent agency tests (UL)

Long term per independent agency tests (UL)

Short term per IEC Type tests

Short term per IEC Type tests

Operating Environment

Page 11 of the GarrettCom PS14P user manual — Packaging:
Page 11 · click to enlarge
Page 11

S14, S14H, S14P & PS14P: 3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x

Cooling MethodConvection on regular model, plus the case is used as a heat sink on
Dimensions, Switch unitHeight x Width x Depth
Weightall S14 models: 4.6 oz. (130g);

Enclosure: Robust sheet metal (Steel).

power supply, –d, and i5.9 oz (170g)
–Pd, and =Pi7.9 oz (225g)
PS14P units9.6 oz (272g)
–Hd, and Hi5.8 oz (165g)

altitude.

“H” and “P” models.

2.5 cm)

Packaging:

Page 12 of the GarrettCom PS14P user manual — UL listed class II Power Supply, ( AC External):
Page 12 · click to enlarge
Page 12

These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked

500mA).When connected to a 48 V centralized dc source these products shall be provided with a Listed 5 A DC fuse in the supply circuit.

Input: 120vac at 60 Hz for “d” models, 240vac at 50Hz for “i” models that have IEC320

Input100-240V AC at 47-63Hz, for “-Hd” high temp., 100-240V AC at 47-63Hz “-for
Input100-240V AC at 47-63Hz, for “-Pd” high temp. 100-240V AC at 47-63Hz, “-Pi”

“Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output

voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to

Power input (8-15)V DC, jack is 2.5mm center +ve , with 6ft. cord

Hi” models that have IEC320 power connector built-in the PS unit.

models that have IEC320 power connector built-in the PS unit.

power connector built-in the PS unit. Out put- 12vdc, 1 Amps

UL listed class II Power Supply, ( AC External):

POWER SUPPLY (S14 Model only)

Out put- 12vdc, 1.25 Amps

Out put- 12vdc, 2 Amps

Page 13 of the GarrettCom PS14P user manual — POWER INPUT: (PS14P(POE) unit only)
Page 13 · click to enlarge
Page 13

24V DC internal (range of 18 to 36V DC)

GarrettCom PS14P — Power Supply ( Direct DC ): built-in screw terminal diagram (page 13)
Fig. 4 · Power Supply ( Direct DC ): built-in screw terminal
GarrettCom PS14P — Power Supply ( Direct DC ): built-in screw terminal diagram (page 13)
Fig. 5 · Power Supply ( Direct DC ): built-in screw terminal
GarrettCom PS14P — Power Supply ( Direct DC ): built-in screw terminal diagram (page 13)
Fig. 6 · Power Supply ( Direct DC ): built-in screw terminal
Total Power Consumption66 watts max. (1.4A @48VDC)

block for +, -, ground. The 12V DC jack is also present.

DC to unit12V DC, 2.5mm jack, center +ve, 6ft. cord

Power Supply ( Direct DC ): built-in screw terminal

Power Consumption: 3 watts typical, 4 watts max.

-48V DC internal (range of 36 to 60V DC) t.

12V DC internal (range of 8.0 to 15V DC),

POWER INPUT: (PS14P(POE) unit only)

Page 14 of the GarrettCom PS14P user manual — POWER OUTPUT: (PS14P(POE) unit only)
Page 14 · click to enlarge
Page 14

15V DC jack is also present, but it can only be used to power the PS14P unit itself, not PoE devices attached.

female. Three RJ-45 ports provided in front, and one on the rear. Supports shielded

Terminal block for -48v DC input (range of 46 to 60V dc), built in for +, - , ground. The 8-

PoE available on all four RJ-45 ports via Ethernet twisted pair cabling on port pins using

(STP) and unshielded (UTP) Cat 3, 4, 5 cable. For PoE pass-through option on P

RJ-45 PortAuto-cross(MDIX), 100BASE-TX and 10BASE-T:shielded 8-pin
802,3af Power Consumption61.6 watts max. (15.4(max)/port) PoE Ports Output voltage: 44 to 57 VDC

spare pairs 4,5(+) 7,8(-), not the data pair 1,2(-), 3,6(+)

Over Current Protection, per portresettable fuse

POWER OUTPUT: (PS14P(POE) unit only)

models, use Model # PS14P.

Port Connectors:

Page 15 of the GarrettCom PS14P user manual — Mounting option for S14 Family of Switches:
Page 15 · click to enlarge
Page 15

Mean Tine Between Failure (MTBF) – 15+ years, Telcordia (Bellcore SR-332) Method

10/100: = 100Mbps; OFF = 10 Mbps LK/ACT: Steady ON for LINK with no traffic, blinking indicates port

Rack-mount optionMC14-TRAY, see http://www.garrettcom.com/mc_tray.htm
DIN-Rail mounting optionModel # DIN-RAIL MC2 (see Section 3.4)
PoE, ports 1,2,3,4ON when delivering power (PS14P)
POWERSteady ON when power applied (S14 model)

ON for -48V power applied to the PS14P unit

LED Indicators (Dualfront and end, port #4 has front only)

F/HON = full-duplex, OFF = half-duplex

Metal Mounting clips for panel mounting: included

is transmitting / receiving.

Mounting option for S14 Family of Switches:

Page 16 of the GarrettCom PS14P user manual — Agency Approvals and Standard Compliance:
Page 16 · click to enlarge
Page 16

IEC61850 EMC and Operating Conditions Class C for Power Substations

UL Listed (UL 60950), cUL, CE, Emissions meet FCC Part 15, Class A.

WarrantyThree years, return to factory Made in USA
H & P modelsIEEE P1613 Env. Std for Electric Power Substations
P modelNEMA TS-2 and TEES for traffic control equipment
P modeldesigned for UL 2043 above-the-ceiling installation

Designed for above-the-ceiling (plenum) installation

Agency Approvals and Standard Compliance:

NEBS L3 and ETSI compliant

Page 17 of the GarrettCom PS14P user manual — 1.2 Summary of models and descriptions:
Page 17 · click to enlarge
Page 17

S14P-24VDC = Same as S14P-12VDC model, except Ext. AC Premium power supply not included

S14-d,i = four 10/100 RJ-45 ports Switch, for office and wiring closet env., ext. AC Pwr Supply

S14P-Pd, Pi = ,Premium rated, four 10/100 RJ-45 ports Switch, for un-controlled(outdoor) env.

DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one S14-Series

S14H-12VDC = Same as S14H model, except Ext. AC Hardened power supply not included

S14P-12VDC = Same as S14P-Pd, Pi, except ext. AC Premium Power Supply is not included.

S14H-Hd, Hi = Hardened, four 10/100 RJ-45 ports Switch, Factory floor, Int. 8-15VDC,

Int. 8 to 15V terminal block, Ext. AC Premium-rated Power Supply included.

S14HR-24VDC = Same as S14H-24VDC model, but includes DIN-RAIL-MC2 option.

S14PR-24VDC = Same as S14P-24VDC model, but includes DIN-RAIL-MC2 option.

MC14-TRAY = 19” Rack-mount tray for 14-series Switch models, up to 16 units

S14H-24VDC = Same as S14H-12VDC model, except for 24VDC power input

S14H-48VDC = Same as S14H-24VDC model, except for -48VDC power input.

S14P-48VDC = Same as S14P-24VDC model, except for -48VDC input

1.2 Summary of models and descriptions:

Ext. AC Hardened power supply included .

Page 18 of the GarrettCom PS14P user manual — 2.0 INTRODUCTION
Page 18 · click to enlarge
Page 18

controlled(outdoor) env. All four RJ-45 Ethernet ports support Power Source PoE as per the IEEE

This section describes S14-Series models, including appearance, features and

50 watts to support one PS14P-48VDC Switch and up to 4 attached PoE devices, Try this URL – http://www.lanstore.com/ps.htm

PS14P = ,Premium rated, four 10/100 RJ-45 ports Switch in a compact package, rated for un-

DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one PS14P Switch

Magnum PS14P (PoE) Power Source Switch (model and descriptions)

802.3ad standard. Includes integral -48V DC terminal block for power unit.

MC14-TRAY = 19” Rack-mount tray for 14-series Switch models

2.0 INTRODUCTION

typical applications.

Page 19 of the GarrettCom PS14P user manual — Magnum PS14P (PoE) Power Source Switch (model and descriptions)
Page 19 · click to enlarge
Page 19

product; notify the carrier immediately of any damage which you believe occurred during

1 User Guide, i.e., this manual (continued next page)

shipment or delivery. Inspect the contents of this package for any signs of damage and

2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this

1 External Power Supply, (for S14, S14H, S14P), (d, i model only)

1 set Metal panel mounting clips and screws, 2 each

1 Magnum S14-Series or PS14P Switch Unit

ensure that the items listed below are included.

This package should contain:

Page 20 of the GarrettCom PS14P user manual — Magnum PS14P (PoE) Power Source Switch (model and descriptions)
Page 20 · click to enlarge
Page 20

rated (outdoor) versions. Extra features for heavy-duty and extended temperature operation

return the unit use the original shipping container. Refer to Section 5 Troubleshooting, for

Remove the Magnum S14-Series Switch from the shipping container. Be sure to keep the

ranges are included selectively in the Hardened factory-floor and Premium-rated outdoor

anywhere” Magnum S14 Switch is a versatile and handy solution, and can provide it in a

application environments, with regular (office), Hardened (factory floor), and Premium-

models. Input power may be AC, or DC at 12V, 24V or –48V, providing a selection for

office or for heavy duty industrial applications. This selection of models offers the best

In the event there are items missing or damaged contact your supplier. If you need to

For any user who needs a small chunk of Ethernet connectivity, a 4-port “go

2.2 Product Description The Magnum S14 family of Convenient Switches covers the full range of

shipping container should you need to ship the unit at a later date.

price / value unit for each user and installation.

convenient compact package.

specific return procedures.

Page 21 of the GarrettCom PS14P user manual — PORT 1 PORT 2 PORT 3
Page 21 · click to enlarge
Page 21

Fig2.2a. Magnum S14, Front view (three RJ-45 ports on Front

Fig2.2b. Magnum S14, Rear view (one RJ-45 port on rear

GarrettCom PS14P — PORT 1 PORT 2 PORT 3 diagram (page 21)
Fig. 7

PORT 1 PORT 2 PORT 3

Fig 2.2a

LK/ACT

POWER

LK/ACT

LK/ACT 10/100 9VDC. 1AMP

PORT 4

PORT 4

Show 8 more labels / short text on this page
side) · GarrettCom Magnum S14 · Convenient Switch · Convenient Switch · Magnum S14 · GarrettCom · 10/100 · 10/100
Page 22 of the GarrettCom PS14P user manual — PORT 1 PORT 2 PORT 3
Page 22 · click to enlarge
Page 22

hardened unit designed for factory floor and other industrial applications. The S14H models

cooling, so the S14H resists dust, dirt, moisture, smoke and insects, and is above-the-ceiling

an external AC power supply. A metal case with convection cooling is featured. Operation

The Yellow label S14 shown above are for office and wiring closet environments and use

may be in 0° to 50°C ambient temperature. The units can be mounted securely on a closet

features a sealed metal case that is also used as a heat sink. No air inflow is required for

(plenum) rated. Choices of models for external AC or internal DC power are available.

are built with high-grade components and use special thermal techniques and a rugged

metal case for extended temperature industrial applications. The S14H Hardened unit

The orange-label Magnum S14H as shown above in Fig 2.2c is a

wall or metal cabinet, or by using the metal panel mounting clips included.

Page 23 of the GarrettCom PS14P user manual — LK/ACT
Page 23 · click to enlarge
Page 23

Fig2.2d. Magnum S14H, Rear view (one RJ-45 port and DC option on

Ambient temperature rating is up to –25°C to +60°C for any of the power input types, AC

Fig 2.2c- Magnum S14H, Front view (three RJ-45 ports on Front

GarrettCom PS14P — Fig 2.2d diagram (page 23)
Fig. 8 · Fig 2.2d

side of the unit, as shown in Fig.

rear side) as shown in Fig.

Fig 2.2d

LA3

LA2

PWR

LA1

F/H

PORT 1 PORT 2 PORT 3

Fig 2.2c

LK/ACT

PORT 1 PORT 2 PORT 3

or DC.

LK/ACT

LK/ACT

POWER

PORT 4

LK/ACT 10/100 9VDC. 1AMP

PORT 4

Show 12 more labels / short text on this page
GarrettCom S14 · Left Side View · 10/ 100 · GarrettCom Magnum S14H · Hardened Convenient Switch · Convenient Switch · 10/100 · GarrettCom · Magnum S14H · Hardened · 10/100 · 10/100
Page 24 of the GarrettCom PS14P user manual — PORT 1 PORT 2 PORT 3
Page 24 · click to enlarge
Page 24

extended temperature components, the S14P uses similar thermal

options include panel-mounting, DIN-rail, or rack-mount tray.

outdoor applications. Specially designed with premium-grade

techniques as the S14H hardened units for cooling. Mounting

Ambient temperature rating is –40°C to +75°C for any of the

The red-label Magnum S14P, as shown in Fig. 2.2e, is a

premium rated unit suitable for temperature un-controlled

Choices of models for external AC or internal DC powers

power input types, AC or DC.

are available.

GarrettCom PS14P — Fig. 2.2e diagram (page 24)
Fig. 9 · Fig. 2.2e

Premium Rated Convenient Switch

PORT 1 PORT 2 PORT 3

LK/ACT

POWER

LK/ACT

LK/ACT 10/100 9VDC. 1AMP

PORT 4

PORT 4

Fig. 2.2e

Show 7 more labels / short text on this page
GarrettCom Magnum S14P · Magnum S14P · Premium Rated · Convenient Switch · GarrettCom · 10/100 · 10/100
Page 25 of the GarrettCom PS14P user manual — 2.2.1: Magnum PS14P : 4-port PoE Power Source Switch
Page 25 · click to enlarge
Page 25
GarrettCom PS14P — 2.2.1: Magnum PS14P : 4-port PoE Power Source Switch diagram (page 25)
Fig. 10 · 2.2.1: Magnum PS14P : 4-port PoE Power Source Switch

Industrial Ethernet products with the latest technology while being a cost effective solution

GarrettCom’s continuous efforts of designing reliable and premium-rated

has successfully yielded their first Industrial PoE switch called the Magnum PS14P

2.2.1: Magnum PS14P : 4-port PoE Power Source Switch

Switch. Using an external -48vdc power source, all four of the

locations and temperature-uncontrolled environments with a

The Magnum PS14P PoE Power source

Convenient Switch. Designed and developed with premium-

Convenient Switch combines standard 802.3af Power over

grade extended temperature components, premium-rated

PS14P switches are suitable for use in sheltered outdoor

Ethernet (PoE) with a small heavy duty 4-port Industrial

temperature rating of –40°C to 75°C.

Page 26 of the GarrettCom PS14P user manual — 2.2.1: Magnum PS14P : 4-port PoE Power Source Switch
Page 26 · click to enlarge
Page 26

PS14P’s Ethernet ports can provide Power as well as 10/100 Mb data transmission over the

802.3af PoE standard. The PS14P switch ports have an auto-sensing algorithm, so that they

The PS14P switches are Power Sourcing Equipment (PSE), and are fully compatible with

Powered Devices (PD)(e.g wireless access points, IP phones) that comply with the IEEE

inter-connecting Ethernet cables. So a single Ethernet twisted pair cable will be able to

handshake to protect equipment from damage and to manage power budgets.The

disconnected, and support the 802.3af PoE PSE standard for over-current protection,

provide power only to 802.3af, PoE end devices. PoE is managed by a multi-stage

PS14P ports will discontinue supplying power when the PoE powered devices are

transmit voice, data and power from the attached devices.

under-current detection, and fault protection.

Page 27 of the GarrettCom PS14P user manual — 2.2.1: Magnum PS14P : 4-port PoE Power Source Switch
Page 27 · click to enlarge
Page 27
GarrettCom PS14P — 2.2.1: Magnum PS14P : 4-port PoE Power Source Switch diagram (page 27)
Fig. 11 · 2.2.1: Magnum PS14P : 4-port PoE Power Source Switch

reliability over traditional AC-powered devices. The simplicity of PoE increases reliability

successfully The PS14P is a standards-compliant way to power and connect a few small

the Magnum PS14P can produce significant cost savings as well as flexibility and

and reduces the overall cost of installation and operation.

Magnum PS14P is enabling the efficient deployment of

reliable VoIP and wireless access networking devices to

communications. Furthermore, using PoE switches like

Ethernet devices at the edge of a network where AC

rapidly emerging as an Ethernet option in industrial,

power is not cost-effective to deploy. Since PoE is

commercial, outdoor and military applications, the

increase the efficiency of heavy duty industrial

Page 28 of the GarrettCom PS14P user manual — 2.2.1: Magnum PS14P : 4-port PoE Power Source Switch
Page 28 · click to enlarge
Page 28

These are applications where the Magnum PS14P can be used to provide the power and

(Temperature, Smoke, Heat and other environmental sensors).

data for these PoE Powered Devices, which require 12-13watts maximum.

- Security devices, like retinal scanners or fingerprint readers.

- Wireless LAN access points and WLAN Mobility system

- Factory floor and building control monitoring

- Home automation systems

- Remote Security Camera

- Lighting control.

- VOIP phones · - SNTP Clock · - Fire alarms

Page 29 of the GarrettCom PS14P user manual — 2.2.1: Magnum PS14P : 4-port PoE Power Source Switch
Page 29 · click to enlarge
Page 29

choice for all PoE device applications. The PS14P is a very important convenient source to

Because of the approval of 802.3af PoE standard, the RJ-45 Ethernet jack will become the

first worldwide standard power plug. The futuristic applications of PoE look promising as

The Magnum PS14P(PoE) Switch provides edge access Ethernet ports in a convenient and

Edge Switch (six ports with Fiber option) to meet the Fiber requirement. All PS14P Power

a convenient point (providing Notebook computer, Cell phone charger, and PDA games

temperatures and hardened, rugged enclosures qualify easily to provide a multi-purpose

Magnum CS14- converter switch (two RJ-45 and a 10 or 100Mb fiber port) or an ES42

compact package. For fiber connectivity or additional non- PoE ports, simply add a

The sleek and efficient PS14P, featured with special thermal techniques for harsh

meet all PoE requirements with a multi-choice of options.

through the PoE devices).

Page 30 of the GarrettCom PS14P user manual — 2.2.1: Magnum PS14P : 4-port PoE Power Source Switch
Page 30 · click to enlarge
Page 30
GarrettCom PS14P — 2.2.1: Magnum PS14P : 4-port PoE Power Source Switch diagram (page 30)
Fig. 12 · 2.2.1: Magnum PS14P : 4-port PoE Power Source Switch

Source Convenient Switch models come with two (2) sets of LED indicators. One set is

mounted in the end adjacent to three of the RJ-4 ports for easy viewing when the unit is

48VDC 1.4Amps (66 watts total consumption)

48V DC power supply can be purchased using

to provide 13-15w power on each port to the

PoE unit. The heavy duty Din rail mounted, -

this URLhttp://www.lanstore.com/ps.htm

The Magnum PS14P Power Source Switch

requires a heavy-duty power supply of -

mounted in a rack mount tray.

Page 31 of the GarrettCom PS14P user manual — 2.3 Magnum PS14P & S14-Series, with four (RJ-45) Copper ports
Page 31 · click to enlarge
Page 31

All four ports of the S14-Series convenient switch support auto-cross (MDIX), and perform

Dual LEDs indicating the operating status of ports are mounted on the top as well

The Magnum S14-Series & PS14P chassis house one main PC board. The power

supply is an external AC unit or internal DC via a screw terminal block. The front side of

the chassis has three twisted-pair switched ports and one port is provided on the rear side.

when no PoE devices are attached. While using a 12vdc Adaptor to power on the switch,

indicators for the unit to validate that the unit is turned ON. For each port, there are Link

the unit will not function as a PoE power source switch but as a non-PoE switch only.

as end for convenience and may be viewed from any direction. There are power (PWR)

2.3 Magnum PS14P & S14-Series, with four (RJ-45) Copper ports

the auto-cross in the auto-negotiation mode only.

Page 32 of the GarrettCom PS14P user manual — 2.4 Frame Buffering and Latency
Page 32 · click to enlarge
Page 32

switches. Each frame (or packet) is loaded into the Switch’s memory and inspected before

length and have the correct CRC, i.e., are good packets. This eliminates the propagation of

and Activity (LK/ACT) LEDs indicating traffic that are mounted on the top of the unit as

well as the end. LEDs mounted next to each port indicate (LK/ACT as LA1, LA2, LA3,

The DC power plug connector or “jack” is in the right rear of the chassis. The

forwarding can occur. This technique ensures that all forwarded frames are of a valid

bad packets, enabling all of the available bandwidth to be used for valid information.

LA4), 10/100 (ON for 100Mbps), and full/half duplex (F/H is ON for full duplex).

The Magnum S14-Series & PS14P(PoE) Switches are store-and-forward

internal DC input terminal block is also provided on the rear side of the unit.

2.4 Frame Buffering and Latency

Page 33 of the GarrettCom PS14P user manual — 2.4 Frame Buffering and Latency
Page 33 · click to enlarge
Page 33

When the Switch detects that its free buffer queue space is low, the Switch sends

While other switching technologies such as "cut-through" or "express" impose

minimal frame latency, they will also permit bad frames to propagate out to the Ethernet

Since there is no way to filter frames with a bad CRC (the frame must be present in order

traffic congestion, especially at peak activity. Since collisions and bad packets are more

industry standard (full-duplex only) PAUSE packets out to the devices sending packets to

which allows a traffic catch-up to occur without dropping packets. Then, normal packet

for CRC to be calculated), the result of indiscriminate cut-through forwarding is greater

cause “flow control”. This tells the sending devices to temporarily stop sending traffic,

segments connected. This "cut-through" technique permits collision fragment frames,

which are a result of late collisions, to be forwarded which add to the network traffic.

likely when traffic is heavy, the result of store-and-forward operation is that more

bandwidth is available for good packets when the traffic load is greatest.

Page 34 of the GarrettCom PS14P user manual — 2.4 Frame Buffering and Latency
Page 34 · click to enlarge
Page 34

Switches is a collision-based flow-control mechanism (when operating at half-duplex only).

frames from entering by forcing a collision signal on all receiving half-duplex ports in order

buffering and processing resumes. This flow-control sequence occurs in a small fraction of

Another feature implemented in Magnum S14-Series & PS14P(PoE) Convenient

forwarded to its destination) of the S14-Series & PS14P(PoE) Convenient Switches varies

When the Switch detects that its free buffer queue space is low, the Switch prevents more

with the port-speed types. The length of the frame is a variable here as it is with all store-

forwarding, the latency is 15 microseconds plus the packet time at 10 Mb. For 100Mb-to-

The latency (the time the frame spends in the Switch before it is sent along or

and-forward switches. For 10 Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb

a second and is transparent to an observer. See Section 4.6 for additional details.

100Mb forwarding, the latency is 5 microseconds plus the packet time at 100Mb.

to stop incoming traffic.

Page 35 of the GarrettCom PS14P user manual — 2.4 Frame Buffering and Latency
Page 35 · click to enlarge
Page 35

the LAN, the Magnum S14-Series & Switches provide 10/100 switching in a

Expansion of Ethernet connectivity is needed to connect edge devices into

The compact and robust PS14P(PoE) acts as a Power plug for all the PoE

devices, e.g CCTV camera, VOIP phone, digital clock, and wireless point

- Red-label, premium rated for un-controlled temperatures, outdoors

through its RJ-45 ports and provides a convenient cost-effective power

2.5 Features and Benefits „ Small 4-port 10/100 Switch unit for edge-of-network applications

„ PS14P, Sleek 4-port 10/100 Power Source Switch for PoE devices

„ Three models for three application environments (S14-series)

convenient and compact package that fits right into the site.

- Orange-label, Hardened for the factory floor.

- Yellow-label for the office and wiring closet

source.

Page 36 of the GarrettCom PS14P user manual — 2.4 Frame Buffering and Latency
Page 36 · click to enlarge
Page 36

temperature environments or high EMI noise sites; e.g industrial or outdoor

other domains. Internal address tables are self-learning. All ports are auto-

(front and side) of LEDs to provide status information when viewed at any

Each S14-Series & PS14P Convenient Switch is equipped with two sets

angle or mounting arrangement, rack-mount, DIN-Rail, or panel-mount.

„ Installation is “Plug and Play”, operation is transparent to software

The Magnum S14-Series & PS14P Switches operate as LAN switches

only forwarding those packets from each domain that are needed on the

S14-Series & PS14P are packaged in rugged sheet metal enclosures to

ensure durability and noise immunity, even when placed in extended

„ Two sets of LEDs for viewing status from any angle.

„ Rugged metal case, Industrial grade

applications.

cross.

Page 37 of the GarrettCom PS14P user manual — both present. Dual-source power may increase availability, or be
Page 37 · click to enlarge
Page 37

The 12V DC jack is present on DC-input models, so that the unit can operate

S14-Series power input may be a variety of types, external AC and internal

from an external AC PS, or from DC applied to the terminal block, either or

convenient to move the unit from a test lab out to the factory floor.

48VDC to provide enough power for 13-15watts on each RJ-45 port. The Terminal block for -48V DC input is a range of 46V to 60V DC.

The 802.3af PoE standard PS14P power source switch requires 1.4Amps-

both present. Dual-source power may increase availability, or be

„ AC and DC Power Supplies with extended temperature ratings

DC at 12V, 24V, or -48VDC. AC may be at extreme temperatures.

„ DC-input models can operate as dual-source (S14-series)

„ DC-Power input for PoE Power Source Switch(PS14P)

Page 38 of the GarrettCom PS14P user manual — For S14-Series
Page 38 · click to enlarge
Page 38

compact Magnum S14-series 10/100 Mbps switch functions support a mixed environment

Featuring a compact metal case, Magnum S14-Series & PS14P(POE)

can be installed in minimal space in a rack-mount MC14-TRAY, on DIN-

Switch unit fits in any environment where users need to add a few RJ-45 ports to a LAN

With the three tier “YOR” hardness ratings, Yellow for “office”, Orange for

“Hardened”, Red for “Premium rated (outdoor)”, the Magnum S-14 Series Convenient

„ Efficient Compact design, for all-purpose convenient mounting

challenging industrial applications easier, more economical, and more-reliable. The

quickly and cost effectively. The edge-of–the-network connectivity product makes

2.6 Applications (S14 Series and PS14P(POE) Switches)

Rail (optional) or panel mounting.

For S14-Series

Page 39 of the GarrettCom PS14P user manual — 2.6 Applications (S14 Series and PS14P(POE) Switches)
Page 39 · click to enlarge
Page 39

Example 1. S14’s-In this example, the Magnum S14 Convenient Switch is used to serve a

ports provide bandwidth for high performance. Port #1 (on the back end) is typically used

of 10 Mbps and 100Mbps users. The switching full / half duplex capability on all four

for an up-stream connection. When expansion is needed, add another S14 and connect it

small office in a factory with multi-servers, print server, internet access and mixed-

into port #1 with twisted pair cabling to add 3 more ports.

Page 40 of the GarrettCom PS14P user manual — LK/ACT
Page 40 · click to enlarge
Page 40

operate at 100Mb as well as at 10 Mb, and utility devices (such as print servers) run at 10

GarrettCom PS14P — F H = X diagram (page 40)
Fig. 13

speed requirements. The users

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

expandiing solution for the non-stopping network demand

S14 Convenient Switches used as a useful & reliable

W W W . G a r r e tt C o m . C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

UPLINK 3 4 5 6 7 8 1S W

UPLINK 3 4 5 6 7 8 1S W

LK/ACT

PORT 1 PORT 2 PORT 3

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

and Workstations 100Mb Servers 100

and Workstations 100Mb Servers 100

LK/ACT

POWER

F/H

F/H

F H = X

F H = X

2SW

2SW

PORT 4

LK/ACT 10/100 9VDC. 1AMP

PORT 4

GARRETT

GARRETT

Show 18 more labels / short text on this page
IBM Compatible · Magnum S14 · Convenient Switch · 10/100 · GarrettCom · 10/100 · Link/Act · Link/Act · Speed · Speed · Tx Rx UPLINK · Tx Rx UPLINK · Workstation · Po wer · Po wer · Error · Error · Laptop computer
Page 41 of the GarrettCom PS14P user manual — F H = X
Page 41 · click to enlarge
Page 41

carry the data to the main workstation being controlled by the Industrial Engineering crews.

Mbps. High performance users need a high bandwidth up-link for access to a central LAN

and central file servers. Any attached node can change speed at any time without affecting

network operation or impacting other users. The multi-functional S14 Convenient switches

plug-n-play, Din-Rail mountings and dual LEDs make this compact and convenient switch

Example 2. S14HsIn this application in an expanding Industrial network environment,

provide this solution very efficiently and economically. Various features included MDIX,

the new PLC units are deployed on all the present networks and need an Ethernet port to

networking equipment is being installed in highly controlled temp environments and

The hardened version of Magnum S14Hs are typically used where 10/100BASE-T

require an effective and economical solution to satisfy the need.

a very effective solution for this requirement.

Page 42 of the GarrettCom PS14P user manual — PWR
Page 42 · click to enlarge
Page 42
GarrettCom PS14P — PLC diagram (page 42)
Fig. 14

S14H Convenient Switches provided a secure economical

solution for expanding Industrial network

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

W W W . G a r r e t tC o m . C o m

PLC

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PWR

LA3

LA1

LA2

F/H

PORT 1 PORT 2 PORT 3

LK/ACT

PORT 1 PORT 2 PORT 3

LK/ACT

LK/ACT

POWER

PORT 4

LK/ACT 10/100 9VDC. 1AMP

PORT 4

Show 9 more labels / short text on this page
GarrettCom Magnum S14 · Convenient Switch · 10/ 100 · 10/100 · GarrettCom · Magnum S14 · Convenient Switch · 10/100 · 10/100
Page 43 of the GarrettCom PS14P user manual — Example 3: S14Ps
Page 43 · click to enlarge
Page 43

applications. The S14H Switches act as a network edge connectivity unit to satisfy ongoing

duplex switching capability, the S14Ps provide a very economical high bandwidth solution

Built with high-grade components, efficient thermal techniques of cooling, and equipped

with a wide variety of options of AC and DC power supplies, the cost-effective Magnum

The Magnum S14Ps fit very well in high temperature locations (control rooms)

at each copper-cable user-access point. The 10/100 dual-speed functions support a mixed

environment of 10 Mbps and 100Mbps users and devices unconditionally. The switching

experiencing a need to scale their LAN quickly and cost effectively. With its half / full

capability on all ports provides bandwidth for high performance. The ruggedness of the

S14Hs Convenient Switches easily qualify to be used in highly controllable industrial

S14Ps steel case and the high reliability of the design compliments the temperature

controlled packaging to provide an exceptional Ethernet product.

needs very efficiently and economically.

Example 3: S14Ps

Page 44 of the GarrettCom PS14P user manual — Example 3: S14Ps
Page 44 · click to enlarge
Page 44

In this example, the

S14Ps take care of the LAN connectivity requirement in a harsh temperature environment

GarrettCom PS14P — Example 3: S14Ps diagram (page 44)
Fig. 15 · Example 3: S14Ps

S14P Convenient Switches provided a secure dependable,

reliable solution for un-controlled temp. environment

M a g n u m m P 6 2

W W W . G a r r e t t C o m . C o m

M a g n u m m P 6 2

extended temperature rated

Page 45 of the GarrettCom PS14P user manual — Example 4a. Magnum PS14P (Power Source Switch) for PoE device only
Page 45 · click to enlarge
Page 45

power inputs qualifies the Magnum S14Ps to provide a dependable, reliable and economical

expansion of their factory network is being done to extend their capacity and make it more

blue tooth wireless was also implemented to eliminate the cable wiring between the PS14P

solution for remote locations where providing power through wire is not only difficult but

mounted above the ceiling in the building. The steel enclosure and wide selections of DC

solution for any temperature un-controlled environments. This sleek designed convenient

secure through CCTV cameras which monitor the day-to day manufacturing process. The

The Magnum PS14P(PoE) Power source switch is an effective and convenient

expensive too. The cost-effective and efficient Magnum PS14P with its robust enclosure

Switch with PoE ports are capable of carrying data, power, and voice over RJ-45 cable

provides a very economical solution through its 4-PoE RJ-45 ports. The Power Source

This example is an Industrial application, where the

(PoE) switches. The un-controlled temperature and the electric wiring were the big

Example 4a. Magnum PS14P (Power Source Switch) for PoE device only

Switch can easily meet the ongoing demand of a growing network.

challenges to meet at this requirement.

using Magnum PS14P(PoE) units.

Page 46 of the GarrettCom PS14P user manual — Example 4b. Magnum PS14P (Power Source Switch) for PoE device only
Page 46 · click to enlarge
Page 46
GarrettCom PS14P — Example 4b. Magnum PS14P (Power Source Switch) for PoE device only diagram (page 46)
Fig. 16 · Example 4b. Magnum PS14P (Power Source Switch) for P…

complete floor with wireless to avoid more cabling mess and connect all the status delivery

In another application for the Industrial floor, the requirement is to provide the

Data to PoE devices, e.g PoE video camera, and wireless access

Example 4b. Magnum PS14P (Power Source Switch) for PoE device only

expanding solution for the non-stopping network demand, by providing

PS14P Power Source Switches used as a reliable cost-

joints with VOIP phones.

point · power, · Video

Page 47 of the GarrettCom PS14P user manual — Example 4b. Magnum PS14P (Power Source Switch) for PoE device only
Page 47 · click to enlarge
Page 47

wireless networking tools to increase the efficiency of communication across the enterprise.

The Magnum PS14P(POE) is enabling the efficient deployment of reliable VoIP and

Furthermore, using PoE devices like the Magnum PS14P(PoE) has significant cost savings,

The PS14P(PoE) is being recommended to fulfill this requirement to make the

upgrade more cost-effective and avoid another un-necessary electrical cable expansions.

The sleek industrial proof Magnum PS14P(PoE) with its power Source Switch capability,

easily meets the demand to provide power through its RJ-45 cable, and allows for a very

flexibility, and reliability advantages over traditional AC power. They reduce the overall

cost of network ownership. The PoE devices used for this industrial application are VOIP

for voice, Wireless points for wi-fi connection,and a PoE Clock to synchronize the time

with the SNTP server for every second correct timing.

neat Network setup.

Page 48 of the GarrettCom PS14P user manual — IBM
Page 48 · click to enlarge
Page 48
GarrettCom PS14P — IBM diagram (page 48)
Fig. 17

PS14P Power Source Switches used as a reliable cost-effective solution for

IBM

providing Data, Power and Voice over RJ-45 Ports for Industrial application

Data to PoE devices, e.g PoE Clock, VOIP phone and

IBM

Wireless points

Page 49 of the GarrettCom PS14P user manual — 3.0 INSTALLATION
Page 49 · click to enlarge
Page 49

Installation of the Magnum S14-Series & PS14P(PoE) Switches is a simple procedure.

This section describes the installation of the Magnum S14-Series & PS14P(PoE)

location. Metal mounting clips and screws are included for a rugged and secure mounting

The installation location is dependent upon the physical layout of the Ethernet network and

Secure attachment of mounting

lightweight design of the Magnum S-Series allows it to be easily installed in almost any

clips for Panel-

in any orientation. An option DIN-Rail bracket is available.

used as a useful economical tool to expand the

3.1 Locating the Convenient Switch Unit All the S14-Series & PS14P(PoE) Switches

operate in transparent half-and full-duplex

mode. The store and forward switch easily

take care of the network traffic and can be

Convenient Switches, including location,

mountings, power supply and media

existing network. The compact and

3.0 INSTALLATION

connection.

Page 50 of the GarrettCom PS14P user manual — Secure attachment of mounting
Page 50 · click to enlarge
Page 50

an AC power outlet or power strip and where convection cooling is not inhibited. The green

Power (PWR) Led must turn ON when power is applied through the internal DC input 12V,

GarrettCom PS14P — Secure attachment of mounting diagram (page 50)
Fig. 18 · Secure attachment of mounting

associated cabling. Make sure the unit is installed in a location that is easily accessible to

For 19” rack-mounting of Magnum S14-Series & PS14P(PoE) Convenient Switches, a

3.2 MC14-TRAY for Rack Mounting of S14-Series & PS14P(POE) Switches

24V or –48V DC or external AC through 9V DC jack.

rack-mount tray is available, the

The Convenient Switches along

and DC power jacks in the back,

with either fiber or BNC cable in

with Media Converter units are

mounted with their RJ-45 ports

part number is MC14-TRAY.

Page 51 of the GarrettCom PS14P user manual — 3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media Converters
Page 51 · click to enlarge
Page 51

the front. Any mix of the Convenient Switches, Media Converters may be placed on a tray,

PS14P(POE) Switches together in a 19” rack-mount tray. These models comes with built-in

up to a maximum of 16 units. (The mounting spaces of the MC14-TRAY are specific to the

“S14”-series, and do not permit other models). A typical installation of the model MC14-

PS14P(PoE) Convenient Switches, with their power supplies plugged into power strips (not

Mounting the mix-match of 10Mbps and 100Mbps Media Converters and the S14-Series &

included) in the rear area of the tray. Metal mounting screws in the bottom-front hold the

each unit to be viewed for operational status, even when the units are very close together.

common universal AC power supplies rated at 55 watts at 50°C ambient, 12VDC output,

Media Converters firmly in place. The beveled-top edge of the units permit the LEDs of

3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media Converters

The MC14-TR+ PS9 and MC14-TR+PS9X2’s are another option available for Rack

TRAY, 19” rack-mount tray will hold a few (often three to eight) S14-Series &

Page 52 of the GarrettCom PS14P user manual — 3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media Converters
Page 52 · click to enlarge
Page 52

the MC14 -TR models are specific to the

(The MC mounting spaces of

Magnum S14-Series 10Mbps (FT14 and

TB14) and 100Mb (14E) series, and do

and supporting up to 10 Switches for MC14-TR+PS9 and 16 units S14-Series for MC14-

supply. These models are equipped with auto-ranging AC input to the power supplies for

The side-view picture shown

TR+PS9X2. The MC14-TR+PS9X2 Model has two groups of eight units per power

here (above) is an example of an

models to be put in the tray).

use worldwide.

GarrettCom PS14P — 3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media Converters diagram (page 52)
Fig. 19 · 3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Me…

not permit other

Page 53 of the GarrettCom PS14P user manual — 3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media Converters
Page 53 · click to enlarge
Page 53

installation of the model MC14-TR+PS9, 19” rack-mount tray, holding a few S14-Series ,

into the built-in common AC power supply in the rear area of the tray. (PS units that come

10Mbps FT14’s and 100Mb 14E Media Converters, each with their power input plugged

Metal mounting screws in the bottom-front hold each of the media converters

secure in the tray, separately removable for service. The dual LEDs permit viewing

operating status of the S14-Sereis Convenient Switches from any angle.

with the MC’s are not used).

Page 54 of the GarrettCom PS14P user manual — A Magnum
Page 54 · click to enlarge
Page 54

“Factory Floor” Industrial Ethernet environments, are also available for DIN-Rail mounting

GarrettCom PS14P — A Magnum diagram (page 54)
Fig. 20 · A Magnum

3.4 DIN-Rail mounting option The Magnum PS14P, S14HR & S14PR Convenient Switches, designed for use in

The metal DIN-Rail mounting hardware is optional and needs to be ordered as a

DIN-RAIL-MC2. It comes with four

screws to attach the bracket to the MC unit. The

separate item, e.g. Model #

and removal.

A Magnum

PS14P(PoE) with -48VDC supply (left) and S14H

(right) is shown alongside the DIN-Rail-MC2

GarrettCom PS14P — A Magnum diagram (page 54)
Fig. 21 · A Magnum

in an enclosure having DIN Rails.

Show 7 more labels / short text on this page
spring-loaded · with a pull-up · top for easy · Rail clip is · latch at the · “snap-on” · attachment
Page 55 of the GarrettCom PS14P user manual — bracket
Page 55 · click to enlarge
Page 55

power supply designed to be used with UL listed Class II power supplies and the detail info

Magnum S14-Series Switches are power-efficient and can work with an external

AC power supply. Magnum S14-Series require a nominal 12VDC input (range 8 to 15V,

see Specifications) at the jack in the rear. The extended temperature –Hd version is used

The Magnum S14 Models with “HR” have 24VDC power, and have the DIN-

The 12V DC power input has a plug of 2.5mm, center +ve , with 6 ft. cord. All the AC

Rail-MC2 bracket included and assembled with the MC unit at the factory.

3.5 Power Requirements, Power Supply Types for S14-Series Switches

for heavy duty and industrial applications, up to 55`C ambient.

is being provided in Technical Specifications Section 1.1.

bracket

Page 56 of the GarrettCom PS14P user manual — 12VDC 24VDC -48VDC
Page 56 · click to enlarge
Page 56

The various models of Direct DC power type and extended ambient temperature

only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like).

The Internal 12V DC (8 – 15V DC) has a built-in terminal block for +, -, ground. The 9V

DC jack is also present. Detail information about the 12 VDC, the 24V DC and the –48V

The S14-Series are designed to provide reliable operation, withstand higher temperature

power supplies are numerous and your choice needs to be called out on your order.

environments, and provide the Direct DC power choices to the user to deploy in

12VDC 24VDC -48VDC

DC is provided in the Technical Specifications Section 1.1.

uncontrolled temperature environments.

Page 57 of the GarrettCom PS14P user manual — input
Page 57 · click to enlarge
Page 57

12VDC, 24VDC or -48VDC power. DC power input may be chosen for high-availability.

into temperature uncontrolled environments, rated at –40`C to +75`C. The DC jack is also

The extended temperature capability of the Direct DC-powered S14P’s can go

GarrettCom PS14P — input diagram (page 57)
Fig. 22 · input

3.6 Powering the S14H & S14P (DC internal) with 12V, 24V or –48VDC power

models support a range of power input types.

supply, and have built-in screw terminals for

secure attachment of the power leads. Three

reliably equipped with a Direct DC power

The three model choices are for use with

Each Magnum S14H/S14P is

input

Page 58 of the GarrettCom PS14P user manual — 18 – 36V DC (24V DC)
Page 58 · click to enlarge
Page 58

present and optionally can be used with an external P-rated AC power supply to provide

GNDTerminal for “earth” or ground wire connection to the S14H chassis

Power Consumption: 3 watts typical, 4 watts max.

36 – 60V DC (-48V DC)

0.4 amp max.(24V DC)

0.2 amp max.(-48V DC)

Input Voltage8 - 15V DC (12V DC)

18 – 36V DC (24V DC)

Input current0.8 amp.(12V DC)
DC Power Terminals“+”, “-”, floating

“dual source” power input.

Page 59 of the GarrettCom PS14P user manual — 3.7 S14H & S14P, DC-powered, -48VDC, 24VDC and 9VDC Installation
Page 59 · click to enlarge
Page 59
GarrettCom PS14P — input diagram (page 59)
Fig. 23 · input

terminals are identified as positive (+) and negative (-), and they are floating inside the unit

so that the user if desired may ground either of the terminals. The chassis is “earth” or

3.7 S14H & S14P, DC-powered, -48VDC, 24VDC and 9VDC Installation

12VDC leads) to the Direct DC power terminal

terminal block on the Magnum S14H is located

on the left side of the unit and is equipped with

converter (as shown in Figure above). The DC

connection of the -48VDC leads (or 24VDC,

block on the Magnum S14H hardened media

three (3) screw-down lead posts. The power

This section describes the proper

ground (GND).

Page 60 of the GarrettCom PS14P user manual — input
Page 60 · click to enlarge
Page 60

S14H’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is

The connection procedure is straightforward. Simply insert the DC leads to the

optional; it connects to the S14H chassis. Ensure that each lead is securely tightened from

and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead

will connect to the post labeled “+ve” and the rest to the “-ve”.

When power is applied, the green PWR LED will illuminate.

The GND can be hooked up last.

the top, as shown here.

Page 61 of the GarrettCom PS14P user manual — POWER OUTPUT:
Page 61 · click to enlarge
Page 61

PS14P(POE) unit when no PoE devices are attached. The device will not function as PoE

PoE available on all four RJ-45 ports via Ethernet twisted pair cabling on port pins using

GarrettCom PS14P — input diagram (page 61)
Fig. 24 · input

Terminal block for -48v DC input (range of 46 to 60V dc), built in for +, - , ground.

3.7.1 Power Requirement for Magnum PS14P(PoE) Power Source Switch

Switch while powered up via 12VDC power, but as a normal non-PoE Switch.

POWER INPUTTotal Power Consumption: 66 watts max. (1.4A @48VDC)

bought directly using this URL: http://www.lanstore.com/ps.htm

spare pairs 4,5(+) 7,8(-), not the data pair 1,2(-), 3,6(+)

Power Consumption: Typical 3 watts, 4 watts maxm.

Over Current Protection, per portreset able fuse
802,3af Power Consumption61.6 watts max. (15.4(max)/port)
PoE Ports Output voltage44 to 57 VDC

POWER OUTPUT:

Page 62 of the GarrettCom PS14P user manual — input
Page 62 · click to enlarge
Page 62

The Magnum S14-Series & PS14P(POE) Convenient Switches can be connected

to only one media type with two different speed i.e. 100BASE-TX and 10BASE-T. CAT 5

cables should be used when making 100BASE-TX connections. When the ports are used as

cross(MDIX) for either 10 and 100Mbps. Note that the auto-cross function does

mixed-speed network, since S14-Series & PS14P(POE) switch ports are auto-

Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45

and 100Mbps) be used whenever possible in order to provide flexibility in a

Twisted Pair (CAT 5) 100BASE-TX RJ-45

10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for

Media IEEE Standard Connector

not operate, if the port is fixed or not supporting auto-negotiation.

unshielded twisted pair cabling is 100 meters (328 ft).

3.8 Connecting Twisted Pair (RJ-45 ports)

Page 63 of the GarrettCom PS14P user manual — input
Page 63 · click to enlarge
Page 63

The following procedure describes how to connect a 10BASE-T or 100BASE-TX

3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded)

twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and

does not help, ensure that the cable is connected properly and that the device on the

1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded,
2. Connect the other end of the cable to the corresponding device. 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established. If this
4. For Port # 1 or 1SW, if the LINK LED is not illuminated, move the switch which has a cross-over or up-link for linking to another hub or Switch.

either unshielded or shielded cables and wiring may be used.

other end is powered and is not defective.

shielded twisted pair cables.

Page 64 of the GarrettCom PS14P user manual — 3.8.2 Connections to NICs which support Auto-Negotiation, RJ-45 ports
Page 64 · click to enlarge
Page 64

Fast Link Pulse (FLP) coding for the 100BASE-TX signaling system. When connecting a

NIC to the S14-Sereis, it may be necessary to reload the NIC drivers on the user device if

10BASE-T). When 100Mb operation is agreed and in use, the 10/100 LED is illuminated

properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the

The copper ports of Magnum S14-Series Convenient Switches will function

the NIC has been communicating with a protocol other than 100BASE-TX (such as

3.8.2 Connections to NICs which support Auto-Negotiation, RJ-45 ports

steady ON and is OFF, if 10 Mbps traffic.

Page 65 of the GarrettCom PS14P user manual — 4.1 Dual-Speed Functionality, and Switching
Page 65 · click to enlarge
Page 65

The switched RJ-45 ports are full-duplex and auto-sensing for speed. (See section

software configuring to be done at installation or for maintenance. The internal functions of

The Magnum S14-Series & PS14P(PoE) Convenient Switches provide

four switched ports(three ports in the front and one on the rear). The architecture supports a

“communicate with” 100Mbps users as well as 100Mbps domain. Similarly, the 100Mbps

traffic obeys the rules of 100Mbps Ethernet, and can communicate with 10 Mb domain too.

Magnum S14-Series & PS14P(PoE) units are plug-and-play devices. There is no

2.2). When the connected device is 10 Mbps, the S14s obeys all the rules of 10 Mbps

Ethernet configurations. The 10 Mbps users share a 10 Mbps traffic domain, and can

dual speed switching environment, with auto-negotiation capability.

4.1 Dual-Speed Functionality, and Switching

4.0 OPERATION

both are described below.

Page 66 of the GarrettCom PS14P user manual — Switching, Filtering and Forwarding
Page 66 · click to enlarge
Page 66

the same port segment will be filtered, constraining them to one port and relieving the rest

Each time a packet arrives on one of the switched ports, the decision is taken to

either filter or to forward the packet. Packets whose source and destination addresses on

ports where it is not needed. Packets needed for maintaining the operation of the network

of the network from processing them. A packet whose destination address is on another

port segment will be forwarded to the appropriate port, and will not be sent to the other

The Magnum S14-Series & PS14P(PoE) Convenient Switches operate in the

store-and-forward switching mode, which eliminates bad packets and enables peak

(such as occasional multi-cast packets) are forwarded to all ports.

Switching, Filtering and Forwarding

performance.

Page 67 of the GarrettCom PS14P user manual — Switching, Address Learning
Page 67 · click to enlarge
Page 67

An address-aging algorithm causes least-used addresses to fall out in favor of new

The Magnum S14-Series & PS14P(PoE) units have address table capacity of 2K

node addresses, and are suitable for use in large networks. They are self-learning, so that as

nodes are added or changed, the S14-Series & PS14P(PoE) automatically keeps up with

connecting the S14/PS14P(PoE)’s to other unmanaged switches, legacy hubs, managed

switches, media-converters etc. Please note that there can be conditions with managed

4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing The RJ-45 ports support auto-cross (MDI or MDIX) in the auto-negotiation

mode according to the IEEE 802.3u standard. No crossover cables are needed when

frequently-used addresses. To reset the address buffer, cycle power down-and-up.

Switching, Address Learning

node locations.

Page 68 of the GarrettCom PS14P user manual — input
Page 68 · click to enlarge
Page 68

switches where the switch manager fixes the port settings via software, and the result of

advertises its capability for 10 or 100 Mbps speed and F/H duplex mode, and the device

the auto-negotiation is changed in the managed switch by the manager commands. In

at the other end of the cable should similarly advertise / respond. Both sides will agree

to the speed and mode to be used per the IEEE 802.3u standard. Depending upon the

such cases, the 10/100 speed or the F/H mode may be affected, but auto-cross in the

When an RJ-45 cable connection is made, and each time LINK is enabled,

S14 and PS14P(PoE) Switches will still work. The auto-cross function cannot be

auto-negotiation takes place (except for legacy products, which do not have auto-

negotiation and which go to the default state accordingly). The Magnum Switch

devices connected, this will result in agreement to operate at either 10 Mbps or

100Mbps speed, and full- or half-duplex mode.

disabled.

Page 69 of the GarrettCom PS14P user manual — 10/100 Steady ON for 100Mb speed, OFF for 10Mb speed per port
Page 69 · click to enlarge
Page 69

LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will turn

off in the event connectivity is lost between the ends of the twisted pair segment

represented by LA1, LA2, LA3, & LA4. (Steady On or steady Off indicates no

4.3: Dual LEDs, Front-panel and side-panel (Magnum S14-Series & PS14P(PoE)) LED Description

or a loss of power occurs in the unit or remote device. The Link ports are also

10/100 Steady ON for 100Mb speed, OFF for 10Mb speed per port

F/H Steady ON for Full duplex mode, OFF for half duplex per port

PWR Illuminates GREEN to indicate power applied.

Receive Activity).

Page 70 of the GarrettCom PS14P user manual — 5.0 TROUBLESHOOTING
Page 70 · click to enlarge
Page 70

Mb/s Switch is not performing as expected, do not attempt to repair the unit; instead contact

Should problems develop during installation or operation, this section is intended

to help locate, identify and correct these types of problems. Please follow the suggestions

consistently high performance in all network environments. The installation of Magnum

procedures described in this section or if the Magnum S14-Series & PS14P(PoE) 10/100

INSTALLATION, Section 3.0); the operation is also straightforward and is discussed in

S14-Series & PS14P(PoE) 10/100 Mb/s Switches is a straightforward procedure (see

listed below prior to contacting your supplier. However, if you are unsure of the

All Magnum Ethernet products are designed to provide reliability and

your supplier for assistance or contact GarrettCom Customer Support.

5.0 TROUBLESHOOTING

Section 4.

Page 71 of the GarrettCom PS14P user manual — input
Page 71 · click to enlarge
Page 71

the Installation Section of the applicable chapter of this manual. Also check to

during installation. (About 90% of network downtime can be attributed to wiring

Series & PS14P(PoE) unit. Be certain that each AC power cord is plugged into a

functioning electrical outlet. Use the PWR LEDs to verify each unit is receiving

the problem device is replaced with a known good device. Verify whether or not

the problem is corrected. If not, go to Step 5 below. If the problem is corrected,

connected and the cables/wires have not been crimped or in some way impaired

S14-Series & PS14P(PoE) 10/100 Mb/s switch product, it is recommended that

5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to

3. Make sure that an AC power cord is properly attached to each Magnum S14-
2. Check the cables and connectors to ensure that they have been properly
4. If the problem is isolated to a network device other than the Magnum

make sure that the various components of the network are interoperable.

and connector problems.)

power.

Page 72 of the GarrettCom PS14P user manual — input
Page 72 · click to enlarge
Page 72
5. If the problem continues after completing Step 4 above, contact your supplier of

the Magnum S14-Series & PS14P(PoE) 10/100 Mb/s Switch unit or if unknown,

2. An accurate list of GarrettCom product model(s)involved, with serial number(s).

contact GarrettCom, Inc by fax, phone or email (support@garrettcom.com) for

Include the date(s) that you purchased the products from your supplier.

d. Any particular application that, when used, appears to create the problem;

the Magnum S14-Series & PS14P(PoE) Switch and its associated cables are

1. A complete description of the problem, including the following points:

5.2 When Calling for Assistance Please be prepared to provide the following information.

c. The components involved in the problem;

a. The nature and duration of the problem;

b. Situations when the problem occurs;

functioning properly.

assistance.

Page 73 of the GarrettCom PS14P user manual — input
Page 73 · click to enlarge
Page 73

the occurrence of the problem. Any changes to system administration procedures

including Convenient computers, workstations, terminals and printers; plus, the

4. A record of changes that have been made to your network configuration prior to

5.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization

3. It is useful to include other network equipment models and related hardware,

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

(RMA) number. To obtain an RMA number, please use this URL -

Name and phone number of your contact person.

Please have the following information readily available:

various network media types being used.

Name of your company / institution

Serial Number (or Invoice Number)

should all be noted in this record.

Your shipping address · Product name

Page 74 of the GarrettCom PS14P user manual — input
Page 74 · click to enlarge
Page 74

GarrettCom will carefully test and evaluate all returned products, will repair products that

are under warranty at no charge, and will return the warranty-repaired units to the sender

details). However, if the problem or condition causing the return cannot be duplicated by

GarrettCom reserves the right to charge for the testing of non-defective units

under warranty. Testing and repair of product that is not under warranty will result in a

5.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions:

with shipping charges prepaid (see Warranty Information, Appendix A, for complete

Failure symptoms, including a full description of the problem.

Packing List Number (or Sales Order Number)

GarrettCom, the unit will be returned as:

No Problem Found.

customer (user) charge.

Date of installation

Page 75 of the GarrettCom PS14P user manual — Fremont, CA 94539
Page 75 · click to enlarge
Page 75
1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet
2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

or bag for shipping protection. ( You may retain all connectors and this

3. GarrettCom is not responsible for your return shipping charges.

This material may cause electro-static shock damage to the unit.

47823 Westinghouse Dr.

Fremont, CA 94539

Attn.: Customer Service

GarrettCom, Inc.

4. Ship the package to:

Installation Guide.)

Page 76 of the GarrettCom PS14P user manual — APPENDIX A: WARRANTY INFORMATION
Page 76 · click to enlarge
Page 76

components in the products that prove to be defective at no charge other than shipping and

has been damaged by misuse, misapplication, or as a result of service or modification other

Please complete the warranty card as this acts as a product registration, and mail

This warranty will not be effective if, in the opinion of GarrettCom, the product

GarrettCom reserves the right to make a charge for handling and inspecting any

GarrettCom, Inc. warrants its products to be free from defects in materials and

workmanship for a period of three (3) years from the date of shipment by GarrettCom.

During this warranty period, GarrettCom will repair or, at its option, replace

handling, provided that the product is returned pre-paid to GarrettCom.

product returned for warranty repair which turns out not to be faulty.

APPENDIX A: WARRANTY INFORMATION

it to GarrettCom within two weeks of your purchase.

than by GarrettCom.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GarrettCom PS14P

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom PS14P

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom PS14P manual PDF

76 pages·645 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…