Magnum S14 Convenient Switch
Installation and User Guide



GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch and Converter
Switches contain no user serviceable parts. Attempted service by unauthorized
Copyright © 2005 GarrettCom, Inc. All rights reserved. No part of this publication may
Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.
experienced with Magnum S14 & PS14P 10/100 Mb/s Convenient Switches,
be reproduced without prior written permission from GarrettCom, Inc.
personnel shall render all warranties null and void. If problems are
consult Section 5, Troubleshooting, of this User Guide.
NEBS is a registered trademark of Telcordia Technologies
UL is a registered trademark of Underwriters Laboratories
Ethernet is a trademark of Xerox Corporation
Printed in the United States of America.
Trademarks

This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to take whatever
Federal Communications Commission
measures may be required to correct the interference.

Please use the mailing address, phone and fax numbers and email address listed below:
47823 Westinghouse Dr. Fremont, CA 94539
GarrettCom, Inc.
Fax (510) 438-9072



4.3: Dual LEDs, Front-panel and side-panel (S14-Series & PS14P(PoE))62
3.7 S14H & S14P, DC-powered, Installation ......................................... 52
3.7.1 Power Requirement for PS14P(PoE) Power Source Switch.......... 54
3.8 Connecting Twisted Pair (RJ-45 ports).............................................. 55
3.8.1 Connecting Twisted Pair ( Unshielded or Shielded)................. 56
3.8.2 Connections to NICs which support Auto-Neg RJ-45 ports...... 57
4.0 OPERATION ....................................................................................... 58
4.1 Dual-Speed Functionality, and Switching ......................................... 58
4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing................ 60
5.1 Before Calling for Assistance ............................................................ 64
5.2 When Calling for Assistance ............................................................. 65
5.4 Shipping and Packaging Information................................................. 67
APPENDIX A: WARRANTY INFORMATION......................................... 69
01/06: Updated the PS14P(POE) Power Source Switch Rev B 05/05: Added Magnum PS14P(POE) Power Source Switch

06/04: Small revision of the Agency Approvals Rev A 03/04: Initial release of this user manual for the S14 Converter Switch
GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or
10/04: Small edit and updates on power supply option. 09/04: Small edit and updates on UL.
model offerings without notice.

Data packets that have the 4-bytes tagged VLAN field (802.1q) inserted in
100Mb: Ethernet IEEE 802.3u, 100BASE-TX, IEEE 802.1p 10 Mb: Ethernet IEEE 802.3, 10BASE-T Power Over Ethernet: IEEE 802.3af (PS14P model only)
them are received and transmitted unchanged.
When a port is operating at 100Mbps:
When a port is operating at 10 Mbps:
Ports Performance
Network Standards

Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.
Latency (not including packet time): 100 to 10 Mbps: 5µs 10 to 100Mbps: 5µs Path Delay Value: 50 BT on all ports
Filter / Forwarding Rate from 100Mbps ports: 148,800 pps max
10BASE-T (Unshielded twisted pair) - 100 m (328 ft)
100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
Maximum Ethernet Segment (or Domain) Lengths
Address buffer age-out time: 300 sec.
(Non-blocking switching)

Ambient Temperature (S14): 32ºF to 104ºF (0ºC to 40ºC) (S14H): -13ºF to 140ºF (-25ºC to 60ºC)
-40ºF to 167ºF (-40ºC to 75ºC)
-40ºF to 167ºF (-40ºC to 75ºC)
(S14P) model to -40ºC
Conformal Coating (optional) Humidity protection
Long term per independent agency tests (UL)
Long term per independent agency tests (UL)
Short term per IEC Type tests
Short term per IEC Type tests
Operating Environment

S14, S14H, S14P & PS14P: 3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x
Enclosure: Robust sheet metal (Steel).
altitude.
“H” and “P” models.
2.5 cm)

These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked
500mA).When connected to a 48 V centralized dc source these products shall be provided with a Listed 5 A DC fuse in the supply circuit.
Input: 120vac at 60 Hz for “d” models, 240vac at 50Hz for “i” models that have IEC320
“Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output
voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to
Power input (8-15)V DC, jack is 2.5mm center +ve , with 6ft. cord
Hi” models that have IEC320 power connector built-in the PS unit.
models that have IEC320 power connector built-in the PS unit.
power connector built-in the PS unit. Out put- 12vdc, 1 Amps
POWER SUPPLY (S14 Model only)
Out put- 12vdc, 1.25 Amps
Out put- 12vdc, 2 Amps

24V DC internal (range of 18 to 36V DC)



block for +, -, ground. The 12V DC jack is also present.
Power Consumption: 3 watts typical, 4 watts max.
-48V DC internal (range of 36 to 60V DC) t.
12V DC internal (range of 8.0 to 15V DC),

15V DC jack is also present, but it can only be used to power the PS14P unit itself, not PoE devices attached.
female. Three RJ-45 ports provided in front, and one on the rear. Supports shielded
Terminal block for -48v DC input (range of 46 to 60V dc), built in for +, - , ground. The 8-
PoE available on all four RJ-45 ports via Ethernet twisted pair cabling on port pins using
(STP) and unshielded (UTP) Cat 3, 4, 5 cable. For PoE pass-through option on P
spare pairs 4,5(+) 7,8(-), not the data pair 1,2(-), 3,6(+)
models, use Model # PS14P.
Port Connectors:

Mean Tine Between Failure (MTBF) – 15+ years, Telcordia (Bellcore SR-332) Method
10/100: = 100Mbps; OFF = 10 Mbps LK/ACT: Steady ON for LINK with no traffic, blinking indicates port
ON for -48V power applied to the PS14P unit
Metal Mounting clips for panel mounting: included
is transmitting / receiving.

IEC61850 EMC and Operating Conditions Class C for Power Substations
UL Listed (UL 60950), cUL, CE, Emissions meet FCC Part 15, Class A.
Designed for above-the-ceiling (plenum) installation
NEBS L3 and ETSI compliant

S14P-24VDC = Same as S14P-12VDC model, except Ext. AC Premium power supply not included
S14-d,i = four 10/100 RJ-45 ports Switch, for office and wiring closet env., ext. AC Pwr Supply
S14P-Pd, Pi = ,Premium rated, four 10/100 RJ-45 ports Switch, for un-controlled(outdoor) env.
S14H-12VDC = Same as S14H model, except Ext. AC Hardened power supply not included
S14P-12VDC = Same as S14P-Pd, Pi, except ext. AC Premium Power Supply is not included.
S14H-Hd, Hi = Hardened, four 10/100 RJ-45 ports Switch, Factory floor, Int. 8-15VDC,
Int. 8 to 15V terminal block, Ext. AC Premium-rated Power Supply included.
S14HR-24VDC = Same as S14H-24VDC model, but includes DIN-RAIL-MC2 option.
S14PR-24VDC = Same as S14P-24VDC model, but includes DIN-RAIL-MC2 option.
MC14-TRAY = 19” Rack-mount tray for 14-series Switch models, up to 16 units
S14H-24VDC = Same as S14H-12VDC model, except for 24VDC power input
S14H-48VDC = Same as S14H-24VDC model, except for -48VDC power input.
S14P-48VDC = Same as S14P-24VDC model, except for -48VDC input
Ext. AC Hardened power supply included .

controlled(outdoor) env. All four RJ-45 Ethernet ports support Power Source PoE as per the IEEE
This section describes S14-Series models, including appearance, features and
50 watts to support one PS14P-48VDC Switch and up to 4 attached PoE devices, Try this URL – http://www.lanstore.com/ps.htm
PS14P = ,Premium rated, four 10/100 RJ-45 ports Switch in a compact package, rated for un-
DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one PS14P Switch
802.3ad standard. Includes integral -48V DC terminal block for power unit.
MC14-TRAY = 19” Rack-mount tray for 14-series Switch models
typical applications.

product; notify the carrier immediately of any damage which you believe occurred during
1 User Guide, i.e., this manual (continued next page)
shipment or delivery. Inspect the contents of this package for any signs of damage and
2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this
1 External Power Supply, (for S14, S14H, S14P), (d, i model only)
1 set Metal panel mounting clips and screws, 2 each
1 Magnum S14-Series or PS14P Switch Unit
ensure that the items listed below are included.
This package should contain:

rated (outdoor) versions. Extra features for heavy-duty and extended temperature operation
return the unit use the original shipping container. Refer to Section 5 Troubleshooting, for
Remove the Magnum S14-Series Switch from the shipping container. Be sure to keep the
ranges are included selectively in the Hardened factory-floor and Premium-rated outdoor
anywhere” Magnum S14 Switch is a versatile and handy solution, and can provide it in a
application environments, with regular (office), Hardened (factory floor), and Premium-
models. Input power may be AC, or DC at 12V, 24V or –48V, providing a selection for
office or for heavy duty industrial applications. This selection of models offers the best
In the event there are items missing or damaged contact your supplier. If you need to
For any user who needs a small chunk of Ethernet connectivity, a 4-port “go
2.2 Product Description The Magnum S14 family of Convenient Switches covers the full range of
shipping container should you need to ship the unit at a later date.
price / value unit for each user and installation.
convenient compact package.
specific return procedures.

Fig2.2a. Magnum S14, Front view (three RJ-45 ports on Front
Fig2.2b. Magnum S14, Rear view (one RJ-45 port on rear

Fig 2.2a
LK/ACT
POWER
LK/ACT
LK/ACT 10/100 9VDC. 1AMP
PORT 4
PORT 4

hardened unit designed for factory floor and other industrial applications. The S14H models
cooling, so the S14H resists dust, dirt, moisture, smoke and insects, and is above-the-ceiling
an external AC power supply. A metal case with convection cooling is featured. Operation
The Yellow label S14 shown above are for office and wiring closet environments and use
may be in 0° to 50°C ambient temperature. The units can be mounted securely on a closet
features a sealed metal case that is also used as a heat sink. No air inflow is required for
(plenum) rated. Choices of models for external AC or internal DC power are available.
are built with high-grade components and use special thermal techniques and a rugged
metal case for extended temperature industrial applications. The S14H Hardened unit
The orange-label Magnum S14H as shown above in Fig 2.2c is a
wall or metal cabinet, or by using the metal panel mounting clips included.

Fig2.2d. Magnum S14H, Rear view (one RJ-45 port and DC option on
Ambient temperature rating is up to –25°C to +60°C for any of the power input types, AC
Fig 2.2c- Magnum S14H, Front view (three RJ-45 ports on Front

side of the unit, as shown in Fig.
rear side) as shown in Fig.
LA3
LA2
PWR
LA1
F/H
PORT 1 PORT 2 PORT 3
Fig 2.2c
LK/ACT
PORT 1 PORT 2 PORT 3
or DC.
LK/ACT
POWER
PORT 4
LK/ACT 10/100 9VDC. 1AMP
PORT 4

extended temperature components, the S14P uses similar thermal
options include panel-mounting, DIN-rail, or rack-mount tray.
outdoor applications. Specially designed with premium-grade
techniques as the S14H hardened units for cooling. Mounting
Ambient temperature rating is –40°C to +75°C for any of the
The red-label Magnum S14P, as shown in Fig. 2.2e, is a
premium rated unit suitable for temperature un-controlled
Choices of models for external AC or internal DC powers
power input types, AC or DC.
are available.

Premium Rated Convenient Switch
LK/ACT
POWER
LK/ACT
LK/ACT 10/100 9VDC. 1AMP
PORT 4
PORT 4
Fig. 2.2e


Industrial Ethernet products with the latest technology while being a cost effective solution
GarrettCom’s continuous efforts of designing reliable and premium-rated
has successfully yielded their first Industrial PoE switch called the Magnum PS14P
Switch. Using an external -48vdc power source, all four of the
locations and temperature-uncontrolled environments with a
The Magnum PS14P PoE Power source
Convenient Switch. Designed and developed with premium-
Convenient Switch combines standard 802.3af Power over
grade extended temperature components, premium-rated
PS14P switches are suitable for use in sheltered outdoor
Ethernet (PoE) with a small heavy duty 4-port Industrial
temperature rating of –40°C to 75°C.

PS14P’s Ethernet ports can provide Power as well as 10/100 Mb data transmission over the
802.3af PoE standard. The PS14P switch ports have an auto-sensing algorithm, so that they
The PS14P switches are Power Sourcing Equipment (PSE), and are fully compatible with
Powered Devices (PD)(e.g wireless access points, IP phones) that comply with the IEEE
inter-connecting Ethernet cables. So a single Ethernet twisted pair cable will be able to
handshake to protect equipment from damage and to manage power budgets.The
disconnected, and support the 802.3af PoE PSE standard for over-current protection,
provide power only to 802.3af, PoE end devices. PoE is managed by a multi-stage
PS14P ports will discontinue supplying power when the PoE powered devices are
transmit voice, data and power from the attached devices.
under-current detection, and fault protection.


reliability over traditional AC-powered devices. The simplicity of PoE increases reliability
successfully The PS14P is a standards-compliant way to power and connect a few small
the Magnum PS14P can produce significant cost savings as well as flexibility and
and reduces the overall cost of installation and operation.
Magnum PS14P is enabling the efficient deployment of
reliable VoIP and wireless access networking devices to
communications. Furthermore, using PoE switches like
Ethernet devices at the edge of a network where AC
rapidly emerging as an Ethernet option in industrial,
power is not cost-effective to deploy. Since PoE is
commercial, outdoor and military applications, the
increase the efficiency of heavy duty industrial

These are applications where the Magnum PS14P can be used to provide the power and
(Temperature, Smoke, Heat and other environmental sensors).
data for these PoE Powered Devices, which require 12-13watts maximum.
- Security devices, like retinal scanners or fingerprint readers.
- Wireless LAN access points and WLAN Mobility system
- Factory floor and building control monitoring
- Home automation systems
- Remote Security Camera
- Lighting control.
- VOIP phones · - SNTP Clock · - Fire alarms

choice for all PoE device applications. The PS14P is a very important convenient source to
Because of the approval of 802.3af PoE standard, the RJ-45 Ethernet jack will become the
first worldwide standard power plug. The futuristic applications of PoE look promising as
The Magnum PS14P(PoE) Switch provides edge access Ethernet ports in a convenient and
Edge Switch (six ports with Fiber option) to meet the Fiber requirement. All PS14P Power
a convenient point (providing Notebook computer, Cell phone charger, and PDA games
temperatures and hardened, rugged enclosures qualify easily to provide a multi-purpose
Magnum CS14- converter switch (two RJ-45 and a 10 or 100Mb fiber port) or an ES42
compact package. For fiber connectivity or additional non- PoE ports, simply add a
The sleek and efficient PS14P, featured with special thermal techniques for harsh
meet all PoE requirements with a multi-choice of options.
through the PoE devices).


Source Convenient Switch models come with two (2) sets of LED indicators. One set is
mounted in the end adjacent to three of the RJ-4 ports for easy viewing when the unit is
48VDC 1.4Amps (66 watts total consumption)
48V DC power supply can be purchased using
to provide 13-15w power on each port to the
PoE unit. The heavy duty Din rail mounted, -
The Magnum PS14P Power Source Switch
requires a heavy-duty power supply of -
mounted in a rack mount tray.

All four ports of the S14-Series convenient switch support auto-cross (MDIX), and perform
Dual LEDs indicating the operating status of ports are mounted on the top as well
The Magnum S14-Series & PS14P chassis house one main PC board. The power
supply is an external AC unit or internal DC via a screw terminal block. The front side of
the chassis has three twisted-pair switched ports and one port is provided on the rear side.
when no PoE devices are attached. While using a 12vdc Adaptor to power on the switch,
indicators for the unit to validate that the unit is turned ON. For each port, there are Link
the unit will not function as a PoE power source switch but as a non-PoE switch only.
as end for convenience and may be viewed from any direction. There are power (PWR)
the auto-cross in the auto-negotiation mode only.

switches. Each frame (or packet) is loaded into the Switch’s memory and inspected before
length and have the correct CRC, i.e., are good packets. This eliminates the propagation of
and Activity (LK/ACT) LEDs indicating traffic that are mounted on the top of the unit as
well as the end. LEDs mounted next to each port indicate (LK/ACT as LA1, LA2, LA3,
The DC power plug connector or “jack” is in the right rear of the chassis. The
forwarding can occur. This technique ensures that all forwarded frames are of a valid
bad packets, enabling all of the available bandwidth to be used for valid information.
LA4), 10/100 (ON for 100Mbps), and full/half duplex (F/H is ON for full duplex).
The Magnum S14-Series & PS14P(PoE) Switches are store-and-forward
internal DC input terminal block is also provided on the rear side of the unit.

When the Switch detects that its free buffer queue space is low, the Switch sends
While other switching technologies such as "cut-through" or "express" impose
minimal frame latency, they will also permit bad frames to propagate out to the Ethernet
Since there is no way to filter frames with a bad CRC (the frame must be present in order
traffic congestion, especially at peak activity. Since collisions and bad packets are more
industry standard (full-duplex only) PAUSE packets out to the devices sending packets to
which allows a traffic catch-up to occur without dropping packets. Then, normal packet
for CRC to be calculated), the result of indiscriminate cut-through forwarding is greater
cause “flow control”. This tells the sending devices to temporarily stop sending traffic,
segments connected. This "cut-through" technique permits collision fragment frames,
which are a result of late collisions, to be forwarded which add to the network traffic.
likely when traffic is heavy, the result of store-and-forward operation is that more
bandwidth is available for good packets when the traffic load is greatest.

Switches is a collision-based flow-control mechanism (when operating at half-duplex only).
frames from entering by forcing a collision signal on all receiving half-duplex ports in order
buffering and processing resumes. This flow-control sequence occurs in a small fraction of
Another feature implemented in Magnum S14-Series & PS14P(PoE) Convenient
forwarded to its destination) of the S14-Series & PS14P(PoE) Convenient Switches varies
When the Switch detects that its free buffer queue space is low, the Switch prevents more
with the port-speed types. The length of the frame is a variable here as it is with all store-
forwarding, the latency is 15 microseconds plus the packet time at 10 Mb. For 100Mb-to-
The latency (the time the frame spends in the Switch before it is sent along or
and-forward switches. For 10 Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb
a second and is transparent to an observer. See Section 4.6 for additional details.
100Mb forwarding, the latency is 5 microseconds plus the packet time at 100Mb.
to stop incoming traffic.

the LAN, the Magnum S14-Series & Switches provide 10/100 switching in a
Expansion of Ethernet connectivity is needed to connect edge devices into
The compact and robust PS14P(PoE) acts as a Power plug for all the PoE
devices, e.g CCTV camera, VOIP phone, digital clock, and wireless point
- Red-label, premium rated for un-controlled temperatures, outdoors
through its RJ-45 ports and provides a convenient cost-effective power
2.5 Features and Benefits Small 4-port 10/100 Switch unit for edge-of-network applications
PS14P, Sleek 4-port 10/100 Power Source Switch for PoE devices
Three models for three application environments (S14-series)
convenient and compact package that fits right into the site.
- Orange-label, Hardened for the factory floor.
- Yellow-label for the office and wiring closet
source.

temperature environments or high EMI noise sites; e.g industrial or outdoor
other domains. Internal address tables are self-learning. All ports are auto-
(front and side) of LEDs to provide status information when viewed at any
Each S14-Series & PS14P Convenient Switch is equipped with two sets
angle or mounting arrangement, rack-mount, DIN-Rail, or panel-mount.
Installation is “Plug and Play”, operation is transparent to software
The Magnum S14-Series & PS14P Switches operate as LAN switches
only forwarding those packets from each domain that are needed on the
S14-Series & PS14P are packaged in rugged sheet metal enclosures to
ensure durability and noise immunity, even when placed in extended
Two sets of LEDs for viewing status from any angle.
Rugged metal case, Industrial grade
applications.
cross.

The 12V DC jack is present on DC-input models, so that the unit can operate
S14-Series power input may be a variety of types, external AC and internal
from an external AC PS, or from DC applied to the terminal block, either or
convenient to move the unit from a test lab out to the factory floor.
48VDC to provide enough power for 13-15watts on each RJ-45 port. The Terminal block for -48V DC input is a range of 46V to 60V DC.
The 802.3af PoE standard PS14P power source switch requires 1.4Amps-
AC and DC Power Supplies with extended temperature ratings
DC at 12V, 24V, or -48VDC. AC may be at extreme temperatures.
DC-input models can operate as dual-source (S14-series)
DC-Power input for PoE Power Source Switch(PS14P)

compact Magnum S14-series 10/100 Mbps switch functions support a mixed environment
Featuring a compact metal case, Magnum S14-Series & PS14P(POE)
can be installed in minimal space in a rack-mount MC14-TRAY, on DIN-
Switch unit fits in any environment where users need to add a few RJ-45 ports to a LAN
With the three tier “YOR” hardness ratings, Yellow for “office”, Orange for
“Hardened”, Red for “Premium rated (outdoor)”, the Magnum S-14 Series Convenient
Efficient Compact design, for all-purpose convenient mounting
challenging industrial applications easier, more economical, and more-reliable. The
quickly and cost effectively. The edge-of–the-network connectivity product makes
Rail (optional) or panel mounting.

Example 1. S14’s-In this example, the Magnum S14 Convenient Switch is used to serve a
ports provide bandwidth for high performance. Port #1 (on the back end) is typically used
of 10 Mbps and 100Mbps users. The switching full / half duplex capability on all four
for an up-stream connection. When expansion is needed, add another S14 and connect it
small office in a factory with multi-servers, print server, internet access and mixed-
into port #1 with twisted pair cabling to add 3 more ports.

operate at 100Mb as well as at 10 Mb, and utility devices (such as print servers) run at 10

speed requirements. The users
PORTS 1SW 2SW 3 4 5 6 7 8
PORTS 1SW 2SW 3 4 5 6 7 8
expandiing solution for the non-stopping network demand
S14 Convenient Switches used as a useful & reliable
W W W . G a r r e tt C o m . C o m
PORTS 1SW 2SW 3 4 5 6 7 8
PORTS 1SW 2SW 3 4 5 6 7 8
UPLINK 3 4 5 6 7 8 1S W
UPLINK 3 4 5 6 7 8 1S W
PORT 1 PORT 2 PORT 3
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
and Workstations 100Mb Servers 100
and Workstations 100Mb Servers 100
POWER
F/H
F/H
F H = X
F H = X
2SW
2SW
PORT 4
LK/ACT 10/100 9VDC. 1AMP
PORT 4
GARRETT
GARRETT

carry the data to the main workstation being controlled by the Industrial Engineering crews.
Mbps. High performance users need a high bandwidth up-link for access to a central LAN
and central file servers. Any attached node can change speed at any time without affecting
network operation or impacting other users. The multi-functional S14 Convenient switches
plug-n-play, Din-Rail mountings and dual LEDs make this compact and convenient switch
provide this solution very efficiently and economically. Various features included MDIX,
the new PLC units are deployed on all the present networks and need an Ethernet port to
networking equipment is being installed in highly controlled temp environments and
The hardened version of Magnum S14Hs are typically used where 10/100BASE-T
require an effective and economical solution to satisfy the need.
a very effective solution for this requirement.


S14H Convenient Switches provided a secure economical
solution for expanding Industrial network
PORTS 1SW 2SW 3 4 5 6 7 8
PORTS 1SW 2SW 3 4 5 6 7 8
W W W . G a r r e t tC o m . C o m
PORTS 1SW 2SW 3 4 5 6 7 8
PORTS 1SW 2SW 3 4 5 6 7 8
LA3
LA1
LA2
F/H
PORT 1 PORT 2 PORT 3
LK/ACT
PORT 1 PORT 2 PORT 3
LK/ACT
LK/ACT
POWER
PORT 4
LK/ACT 10/100 9VDC. 1AMP
PORT 4

applications. The S14H Switches act as a network edge connectivity unit to satisfy ongoing
duplex switching capability, the S14Ps provide a very economical high bandwidth solution
Built with high-grade components, efficient thermal techniques of cooling, and equipped
with a wide variety of options of AC and DC power supplies, the cost-effective Magnum
The Magnum S14Ps fit very well in high temperature locations (control rooms)
at each copper-cable user-access point. The 10/100 dual-speed functions support a mixed
environment of 10 Mbps and 100Mbps users and devices unconditionally. The switching
experiencing a need to scale their LAN quickly and cost effectively. With its half / full
capability on all ports provides bandwidth for high performance. The ruggedness of the
S14Hs Convenient Switches easily qualify to be used in highly controllable industrial
S14Ps steel case and the high reliability of the design compliments the temperature
controlled packaging to provide an exceptional Ethernet product.
needs very efficiently and economically.

In this example, the
S14Ps take care of the LAN connectivity requirement in a harsh temperature environment

S14P Convenient Switches provided a secure dependable,
reliable solution for un-controlled temp. environment
M a g n u m m P 6 2
W W W . G a r r e t t C o m . C o m
M a g n u m m P 6 2
extended temperature rated

power inputs qualifies the Magnum S14Ps to provide a dependable, reliable and economical
expansion of their factory network is being done to extend their capacity and make it more
blue tooth wireless was also implemented to eliminate the cable wiring between the PS14P
solution for remote locations where providing power through wire is not only difficult but
mounted above the ceiling in the building. The steel enclosure and wide selections of DC
solution for any temperature un-controlled environments. This sleek designed convenient
secure through CCTV cameras which monitor the day-to day manufacturing process. The
The Magnum PS14P(PoE) Power source switch is an effective and convenient
expensive too. The cost-effective and efficient Magnum PS14P with its robust enclosure
Switch with PoE ports are capable of carrying data, power, and voice over RJ-45 cable
provides a very economical solution through its 4-PoE RJ-45 ports. The Power Source
This example is an Industrial application, where the
(PoE) switches. The un-controlled temperature and the electric wiring were the big
Switch can easily meet the ongoing demand of a growing network.
challenges to meet at this requirement.
using Magnum PS14P(PoE) units.


complete floor with wireless to avoid more cabling mess and connect all the status delivery
In another application for the Industrial floor, the requirement is to provide the
Data to PoE devices, e.g PoE video camera, and wireless access
expanding solution for the non-stopping network demand, by providing
PS14P Power Source Switches used as a reliable cost-
joints with VOIP phones.
point · power, · Video

wireless networking tools to increase the efficiency of communication across the enterprise.
The Magnum PS14P(POE) is enabling the efficient deployment of reliable VoIP and
Furthermore, using PoE devices like the Magnum PS14P(PoE) has significant cost savings,
The PS14P(PoE) is being recommended to fulfill this requirement to make the
upgrade more cost-effective and avoid another un-necessary electrical cable expansions.
The sleek industrial proof Magnum PS14P(PoE) with its power Source Switch capability,
easily meets the demand to provide power through its RJ-45 cable, and allows for a very
flexibility, and reliability advantages over traditional AC power. They reduce the overall
cost of network ownership. The PoE devices used for this industrial application are VOIP
for voice, Wireless points for wi-fi connection,and a PoE Clock to synchronize the time
with the SNTP server for every second correct timing.
neat Network setup.


PS14P Power Source Switches used as a reliable cost-effective solution for
providing Data, Power and Voice over RJ-45 Ports for Industrial application
Data to PoE devices, e.g PoE Clock, VOIP phone and
Wireless points

Installation of the Magnum S14-Series & PS14P(PoE) Switches is a simple procedure.
This section describes the installation of the Magnum S14-Series & PS14P(PoE)
location. Metal mounting clips and screws are included for a rugged and secure mounting
The installation location is dependent upon the physical layout of the Ethernet network and
lightweight design of the Magnum S-Series allows it to be easily installed in almost any
in any orientation. An option DIN-Rail bracket is available.
used as a useful economical tool to expand the
3.1 Locating the Convenient Switch Unit All the S14-Series & PS14P(PoE) Switches
operate in transparent half-and full-duplex
mode. The store and forward switch easily
take care of the network traffic and can be
Convenient Switches, including location,
mountings, power supply and media
existing network. The compact and
connection.

an AC power outlet or power strip and where convection cooling is not inhibited. The green
Power (PWR) Led must turn ON when power is applied through the internal DC input 12V,

associated cabling. Make sure the unit is installed in a location that is easily accessible to
For 19” rack-mounting of Magnum S14-Series & PS14P(PoE) Convenient Switches, a
3.2 MC14-TRAY for Rack Mounting of S14-Series & PS14P(POE) Switches
24V or –48V DC or external AC through 9V DC jack.
rack-mount tray is available, the
The Convenient Switches along
and DC power jacks in the back,
with either fiber or BNC cable in
with Media Converter units are
mounted with their RJ-45 ports
part number is MC14-TRAY.

the front. Any mix of the Convenient Switches, Media Converters may be placed on a tray,
PS14P(POE) Switches together in a 19” rack-mount tray. These models comes with built-in
up to a maximum of 16 units. (The mounting spaces of the MC14-TRAY are specific to the
“S14”-series, and do not permit other models). A typical installation of the model MC14-
PS14P(PoE) Convenient Switches, with their power supplies plugged into power strips (not
Mounting the mix-match of 10Mbps and 100Mbps Media Converters and the S14-Series &
included) in the rear area of the tray. Metal mounting screws in the bottom-front hold the
each unit to be viewed for operational status, even when the units are very close together.
common universal AC power supplies rated at 55 watts at 50°C ambient, 12VDC output,
Media Converters firmly in place. The beveled-top edge of the units permit the LEDs of
The MC14-TR+ PS9 and MC14-TR+PS9X2’s are another option available for Rack
TRAY, 19” rack-mount tray will hold a few (often three to eight) S14-Series &

the MC14 -TR models are specific to the
(The MC mounting spaces of
Magnum S14-Series 10Mbps (FT14 and
TB14) and 100Mb (14E) series, and do
and supporting up to 10 Switches for MC14-TR+PS9 and 16 units S14-Series for MC14-
supply. These models are equipped with auto-ranging AC input to the power supplies for
The side-view picture shown
TR+PS9X2. The MC14-TR+PS9X2 Model has two groups of eight units per power
here (above) is an example of an
models to be put in the tray).
use worldwide.

not permit other

installation of the model MC14-TR+PS9, 19” rack-mount tray, holding a few S14-Series ,
into the built-in common AC power supply in the rear area of the tray. (PS units that come
10Mbps FT14’s and 100Mb 14E Media Converters, each with their power input plugged
Metal mounting screws in the bottom-front hold each of the media converters
secure in the tray, separately removable for service. The dual LEDs permit viewing
operating status of the S14-Sereis Convenient Switches from any angle.
with the MC’s are not used).

“Factory Floor” Industrial Ethernet environments, are also available for DIN-Rail mounting

3.4 DIN-Rail mounting option The Magnum PS14P, S14HR & S14PR Convenient Switches, designed for use in
The metal DIN-Rail mounting hardware is optional and needs to be ordered as a
DIN-RAIL-MC2. It comes with four
screws to attach the bracket to the MC unit. The
separate item, e.g. Model #
and removal.
PS14P(PoE) with -48VDC supply (left) and S14H
(right) is shown alongside the DIN-Rail-MC2

in an enclosure having DIN Rails.

power supply designed to be used with UL listed Class II power supplies and the detail info
Magnum S14-Series Switches are power-efficient and can work with an external
AC power supply. Magnum S14-Series require a nominal 12VDC input (range 8 to 15V,
see Specifications) at the jack in the rear. The extended temperature –Hd version is used
The Magnum S14 Models with “HR” have 24VDC power, and have the DIN-
The 12V DC power input has a plug of 2.5mm, center +ve , with 6 ft. cord. All the AC
Rail-MC2 bracket included and assembled with the MC unit at the factory.
for heavy duty and industrial applications, up to 55`C ambient.
is being provided in Technical Specifications Section 1.1.

The various models of Direct DC power type and extended ambient temperature
only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like).
The Internal 12V DC (8 – 15V DC) has a built-in terminal block for +, -, ground. The 9V
DC jack is also present. Detail information about the 12 VDC, the 24V DC and the –48V
The S14-Series are designed to provide reliable operation, withstand higher temperature
power supplies are numerous and your choice needs to be called out on your order.
environments, and provide the Direct DC power choices to the user to deploy in
DC is provided in the Technical Specifications Section 1.1.
uncontrolled temperature environments.

12VDC, 24VDC or -48VDC power. DC power input may be chosen for high-availability.
into temperature uncontrolled environments, rated at –40`C to +75`C. The DC jack is also
The extended temperature capability of the Direct DC-powered S14P’s can go

3.6 Powering the S14H & S14P (DC internal) with 12V, 24V or –48VDC power
models support a range of power input types.
supply, and have built-in screw terminals for
secure attachment of the power leads. Three
reliably equipped with a Direct DC power
The three model choices are for use with
Each Magnum S14H/S14P is

present and optionally can be used with an external P-rated AC power supply to provide
Power Consumption: 3 watts typical, 4 watts max.
0.4 amp max.(24V DC)
0.2 amp max.(-48V DC)
“dual source” power input.


terminals are identified as positive (+) and negative (-), and they are floating inside the unit
so that the user if desired may ground either of the terminals. The chassis is “earth” or
12VDC leads) to the Direct DC power terminal
terminal block on the Magnum S14H is located
on the left side of the unit and is equipped with
converter (as shown in Figure above). The DC
connection of the -48VDC leads (or 24VDC,
block on the Magnum S14H hardened media
three (3) screw-down lead posts. The power
This section describes the proper
ground (GND).

S14H’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is
The connection procedure is straightforward. Simply insert the DC leads to the
optional; it connects to the S14H chassis. Ensure that each lead is securely tightened from
and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead
will connect to the post labeled “+ve” and the rest to the “-ve”.
When power is applied, the green PWR LED will illuminate.
The GND can be hooked up last.
the top, as shown here.

PS14P(POE) unit when no PoE devices are attached. The device will not function as PoE
PoE available on all four RJ-45 ports via Ethernet twisted pair cabling on port pins using

Terminal block for -48v DC input (range of 46 to 60V dc), built in for +, - , ground.
Switch while powered up via 12VDC power, but as a normal non-PoE Switch.
spare pairs 4,5(+) 7,8(-), not the data pair 1,2(-), 3,6(+)
Power Consumption: Typical 3 watts, 4 watts maxm.

The Magnum S14-Series & PS14P(POE) Convenient Switches can be connected
to only one media type with two different speed i.e. 100BASE-TX and 10BASE-T. CAT 5
cables should be used when making 100BASE-TX connections. When the ports are used as
cross(MDIX) for either 10 and 100Mbps. Note that the auto-cross function does
mixed-speed network, since S14-Series & PS14P(POE) switch ports are auto-
Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45
and 100Mbps) be used whenever possible in order to provide flexibility in a
Twisted Pair (CAT 5) 100BASE-TX RJ-45
10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for
Media IEEE Standard Connector
not operate, if the port is fixed or not supporting auto-negotiation.
unshielded twisted pair cabling is 100 meters (328 ft).
3.8 Connecting Twisted Pair (RJ-45 ports)

The following procedure describes how to connect a 10BASE-T or 100BASE-TX
3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded)
twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and
does not help, ensure that the cable is connected properly and that the device on the
either unshielded or shielded cables and wiring may be used.
other end is powered and is not defective.
shielded twisted pair cables.

Fast Link Pulse (FLP) coding for the 100BASE-TX signaling system. When connecting a
NIC to the S14-Sereis, it may be necessary to reload the NIC drivers on the user device if
10BASE-T). When 100Mb operation is agreed and in use, the 10/100 LED is illuminated
properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the
The copper ports of Magnum S14-Series Convenient Switches will function
the NIC has been communicating with a protocol other than 100BASE-TX (such as
steady ON and is OFF, if 10 Mbps traffic.

The switched RJ-45 ports are full-duplex and auto-sensing for speed. (See section
software configuring to be done at installation or for maintenance. The internal functions of
The Magnum S14-Series & PS14P(PoE) Convenient Switches provide
four switched ports(three ports in the front and one on the rear). The architecture supports a
“communicate with” 100Mbps users as well as 100Mbps domain. Similarly, the 100Mbps
traffic obeys the rules of 100Mbps Ethernet, and can communicate with 10 Mb domain too.
Magnum S14-Series & PS14P(PoE) units are plug-and-play devices. There is no
2.2). When the connected device is 10 Mbps, the S14s obeys all the rules of 10 Mbps
Ethernet configurations. The 10 Mbps users share a 10 Mbps traffic domain, and can
dual speed switching environment, with auto-negotiation capability.
4.0 OPERATION
both are described below.

the same port segment will be filtered, constraining them to one port and relieving the rest
Each time a packet arrives on one of the switched ports, the decision is taken to
either filter or to forward the packet. Packets whose source and destination addresses on
ports where it is not needed. Packets needed for maintaining the operation of the network
of the network from processing them. A packet whose destination address is on another
port segment will be forwarded to the appropriate port, and will not be sent to the other
The Magnum S14-Series & PS14P(PoE) Convenient Switches operate in the
store-and-forward switching mode, which eliminates bad packets and enables peak
(such as occasional multi-cast packets) are forwarded to all ports.
performance.

An address-aging algorithm causes least-used addresses to fall out in favor of new
The Magnum S14-Series & PS14P(PoE) units have address table capacity of 2K
node addresses, and are suitable for use in large networks. They are self-learning, so that as
nodes are added or changed, the S14-Series & PS14P(PoE) automatically keeps up with
connecting the S14/PS14P(PoE)’s to other unmanaged switches, legacy hubs, managed
switches, media-converters etc. Please note that there can be conditions with managed
4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing The RJ-45 ports support auto-cross (MDI or MDIX) in the auto-negotiation
mode according to the IEEE 802.3u standard. No crossover cables are needed when
frequently-used addresses. To reset the address buffer, cycle power down-and-up.
node locations.

switches where the switch manager fixes the port settings via software, and the result of
advertises its capability for 10 or 100 Mbps speed and F/H duplex mode, and the device
the auto-negotiation is changed in the managed switch by the manager commands. In
at the other end of the cable should similarly advertise / respond. Both sides will agree
to the speed and mode to be used per the IEEE 802.3u standard. Depending upon the
such cases, the 10/100 speed or the F/H mode may be affected, but auto-cross in the
When an RJ-45 cable connection is made, and each time LINK is enabled,
S14 and PS14P(PoE) Switches will still work. The auto-cross function cannot be
auto-negotiation takes place (except for legacy products, which do not have auto-
negotiation and which go to the default state accordingly). The Magnum Switch
devices connected, this will result in agreement to operate at either 10 Mbps or
100Mbps speed, and full- or half-duplex mode.
disabled.

LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will turn
off in the event connectivity is lost between the ends of the twisted pair segment
represented by LA1, LA2, LA3, & LA4. (Steady On or steady Off indicates no
or a loss of power occurs in the unit or remote device. The Link ports are also
F/H Steady ON for Full duplex mode, OFF for half duplex per port
PWR Illuminates GREEN to indicate power applied.
Receive Activity).

Mb/s Switch is not performing as expected, do not attempt to repair the unit; instead contact
Should problems develop during installation or operation, this section is intended
to help locate, identify and correct these types of problems. Please follow the suggestions
consistently high performance in all network environments. The installation of Magnum
procedures described in this section or if the Magnum S14-Series & PS14P(PoE) 10/100
INSTALLATION, Section 3.0); the operation is also straightforward and is discussed in
S14-Series & PS14P(PoE) 10/100 Mb/s Switches is a straightforward procedure (see
listed below prior to contacting your supplier. However, if you are unsure of the
All Magnum Ethernet products are designed to provide reliability and
your supplier for assistance or contact GarrettCom Customer Support.
Section 4.

the Installation Section of the applicable chapter of this manual. Also check to
during installation. (About 90% of network downtime can be attributed to wiring
Series & PS14P(PoE) unit. Be certain that each AC power cord is plugged into a
functioning electrical outlet. Use the PWR LEDs to verify each unit is receiving
the problem device is replaced with a known good device. Verify whether or not
the problem is corrected. If not, go to Step 5 below. If the problem is corrected,
connected and the cables/wires have not been crimped or in some way impaired
S14-Series & PS14P(PoE) 10/100 Mb/s switch product, it is recommended that
5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to
make sure that the various components of the network are interoperable.
and connector problems.)
power.

the Magnum S14-Series & PS14P(PoE) 10/100 Mb/s Switch unit or if unknown,
contact GarrettCom, Inc by fax, phone or email (support@garrettcom.com) for
Include the date(s) that you purchased the products from your supplier.
d. Any particular application that, when used, appears to create the problem;
the Magnum S14-Series & PS14P(PoE) Switch and its associated cables are
5.2 When Calling for Assistance Please be prepared to provide the following information.
c. The components involved in the problem;
a. The nature and duration of the problem;
b. Situations when the problem occurs;
functioning properly.
assistance.

the occurrence of the problem. Any changes to system administration procedures
including Convenient computers, workstations, terminals and printers; plus, the
5.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization
https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.
(RMA) number. To obtain an RMA number, please use this URL -
Name and phone number of your contact person.
Please have the following information readily available:
various network media types being used.
Name of your company / institution
Serial Number (or Invoice Number)
should all be noted in this record.
Your shipping address · Product name

GarrettCom will carefully test and evaluate all returned products, will repair products that
are under warranty at no charge, and will return the warranty-repaired units to the sender
details). However, if the problem or condition causing the return cannot be duplicated by
GarrettCom reserves the right to charge for the testing of non-defective units
under warranty. Testing and repair of product that is not under warranty will result in a
5.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions:
with shipping charges prepaid (see Warranty Information, Appendix A, for complete
Failure symptoms, including a full description of the problem.
Packing List Number (or Sales Order Number)
GarrettCom, the unit will be returned as:
No Problem Found.
customer (user) charge.
Date of installation

or bag for shipping protection. ( You may retain all connectors and this
This material may cause electro-static shock damage to the unit.
47823 Westinghouse Dr.
Attn.: Customer Service
GarrettCom, Inc.
Installation Guide.)

components in the products that prove to be defective at no charge other than shipping and
has been damaged by misuse, misapplication, or as a result of service or modification other
Please complete the warranty card as this acts as a product registration, and mail
This warranty will not be effective if, in the opinion of GarrettCom, the product
GarrettCom reserves the right to make a charge for handling and inspecting any
GarrettCom, Inc. warrants its products to be free from defects in materials and
workmanship for a period of three (3) years from the date of shipment by GarrettCom.
During this warranty period, GarrettCom will repair or, at its option, replace
handling, provided that the product is returned pre-paid to GarrettCom.
product returned for warranty repair which turns out not to be faulty.
it to GarrettCom within two weeks of your purchase.
than by GarrettCom.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.