EN
GarrettCom logo
Official user manual

GarrettCom S14

60 pages·584 KB·Switch·PDF·ENDEFRITNLJA
GarrettCom S14
Table of Contents 22 sections Magnum S14 Convenient Switch · Installation and User Guide · Magnum ™ S14 Convenient Switch ™ · Phone (510) 438-9071 · … ShowHide
Page 1 of the GarrettCom S14 user manual — Magnum S14 Convenient Switch
Page 1 · click to enlarge
Page 1
GarrettCom S14 — Magnum S14 Convenient Switch diagram (page 1)
Fig. 1 · Magnum S14 Convenient Switch

Magnum S14 Convenient Switch

Installation and User Guide

(A member of Converter Switch family)

GarrettCom S14 — Magnum S14 Convenient Switch diagram (page 1)
Fig. 2 · Magnum S14 Convenient Switch
GarrettCom S14 — Magnum S14 Convenient Switch diagram (page 1)
Fig. 3 · Magnum S14 Convenient Switch
Page 2 of the GarrettCom S14 user manual — Installation and User Guide
Page 2 · click to enlarge
Page 2

S14 Convenient Switch Installation and User Guide (09/04)

GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch and Converter

render all warranties null and void. If problems are experienced with Magnum

Copyright © 2004 GarrettCom, Inc. All rights reserved. No part of this publication may

Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.

S14, 10/100 Mb/s Switches products, consult Section 5, Troubleshooting, of

user serviceable parts. Attempted service by unauthorized personnel shall

be reproduced without prior written permission from GarrettCom, Inc.

Magnum ™ S14 Convenient Switch ™

Installation and User Guide

Part #84-00100 Rev. A (06/04)

NEBS is a registered trademark of Telcordia Technologies

UL is a registered trademark of Underwriters Laboratories

Ethernet is a trademark of Xerox Corporation

Printed in the United States of America.

this User Guide.

Trademarks

Page 3 of the GarrettCom S14 user manual — Magnum ™ S14 Convenient Switch ™
Page 3 · click to enlarge
Page 3

S14 Convenient Switch Installation and User Guide (09/04)

This equipment generates, uses and can radiate frequency energy and if not

installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested and

found to comply with the limits for a Class A computing device in accordance with the

specifications in Subpart J of Part 15 of FCC rules, which are designed to provide

reasonable protection against such interference when operated in a commercial

environment. Operation of this equipment in a residential area is likely to cause

interference, in which case the user at his own expense will be required to take whatever

Radio Frequency Interference Statement

measures may be required to correct the interference.

Federal Communications Commission

Page 4 of the GarrettCom S14 user manual — Phone (510) 438-9071
Page 4 · click to enlarge
Page 4

S14 Convenient Switch Installation and User Guide (09/04)

Please use the mailing address, phone and fax numbers and email address listed below:

Websitehttp://www.GarrettCom.com
Emailsupport@ garrettcom.com

GarrettCom, Inc.

Phone (510) 438-9071

213 Hammond Ave. Fremont, CA 94539

Fax (510) 438-9072 · Contacting GarrettCom, Inc

Page 5 of the GarrettCom S14 user manual — Phone (510) 438-9071
Page 5 · click to enlarge
Page 5
Page 5 of the GarrettCom S14 user manual — Phone (510) 438-9071
Page 6 of the GarrettCom S14 user manual — APPENDIX A: WARRANTY INFORMATION......................................... 53
Page 6 · click to enlarge
Page 6

S14 Convenient Switch Installation and User Guide (09/04)

3.7 S14H, DC-powered, -48VDC, 24VDC and 9VDC Installation 38

3.8 Connecting Twisted Pair (RJ-45 ports) 40

3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5) 41

3.8.2 Connections to NICs which support Auto-Negotiation 42

4.0 OPERATION 42

4.1 Dual-Speed Functionality, and Switching 42

4.2 Auto-cross (MDIX),Auto-negotiation and Speed-sensing 45

4.3 Dual LEDs, Front-panel and side-panel (Magnum S14-Series) 46

5.0 TROUBLESHOOTING 47

5.1 Before Calling for Assistance 48

5.2 When Calling for Assistance 49

5.3 Return Material Authorization (RMA) Procedure 50

5.4 Shipping and Packaging Information 51

APPENDIX A: WARRANTY INFORMATION 53

Page 7 of the GarrettCom S14 user manual — Revisions
Page 7 · click to enlarge
Page 7

S14 Convenient Switch Installation and User Guide (09/04)

06/04: Small revision of the Agency Approvals Rev A 03/04: Initial release of this user manual for the S14 Converter Switch

GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or

10/04: Small edit and updates on power supply option. 09/04: Small edit and updates on UL.

model offerings without notice.

Revisions

Page 8 of the GarrettCom S14 user manual — 1.0 SPECIFICATIONS
Page 8 · click to enlarge
Page 8

Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.

Filter / Forwarding Rate from 100Mbps ports: 148,800 pps max

100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3u

Processing typeStore and Forward, non-blocking

When a port is operating at 100Mbps:

When a port is operating at 10 Mbps:

Data Rate10 Mbps

Packet-Processing Between Domains

Auto-learning2K address table
Data Rate100Mbps

1.1 Technical Specifications

1.0 SPECIFICATIONS

Ports Performance · Network Standards

Page 9 of the GarrettCom S14 user manual — Packet-Processing Between Domains
Page 9 · click to enlarge
Page 9
Packet buffers memory128KB,dynamically shared on all domains

Latency (not including packet time): 100 to 10 Mbps: 5µs 10 to 100Mbps: 5µs Path Delay Value: 50 BT on all ports

Ambient Temperature (S14): 32ºF to 104ºF (0ºC to 40ºC) (S14H): -13ºF to 140ºF (-25ºC to 60ºC)

-40ºF to 149ºF (-40ºC to 85ºC)

Long term per independent agency tests (UL)

Long term per independent agency tests (UL)

10BASE-T (Unshielded twisted pair) - 100 m (328 ft)

100BASE-TX (CAT 5 UTP) - 100 m (328 ft)

Short term per IEC Type tests

(S14P)-40 º F to 167 º F (-40 º C to 75 º C)

Maximum Ethernet Segment (or Domain) Lengths

Address buffer age-out time: 300 sec.

Operating Environment

Page 10 of the GarrettCom S14 user manual — Packaging:
Page 10 · click to enlarge
Page 10

S14, S14H, and S14P: 3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x 2.5 cm)

-58ºF to 212ºF (-50ºC to 100ºC)

Short term per IEC Type tests

Storage Temperature, All models-40 º F to 160 º F (-40 º C to 85 º C)
Altitude (All models)-200 to 5000ft. (-60 – 15,000 m)
Ambient Relative Humidity5% to 95% (non-condensing)
Cold Start(S14H) model to -20ºC

(S14P) model to -40ºC

Dimensions, Switch unitHeight x Width x Depth

Conformal Coating (optional) Humidity protection

Enclosure: Rugged sheet metal (Steel).

power supply, –d, and i5.9 oz (170g)
Weightall models: 4.6 oz. (130g);

altitude.

Packaging:

Page 11 of the GarrettCom S14 user manual — POWER SUPPLY
Page 11 · click to enlarge
Page 11

These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked

500mA).When connected to a 48 V centralized dc source these products shall be provided

“Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output

voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to

Cooling MethodConvection on regular model, plus the case is used as a heat sink on

Power input (8-15)V DC, jack is 2.5mm center +ve , with 6ft. cord

UL listed class II Power Supply, ( AC External):

–Pd, and =Pi7.9 oz (225g)
–Hd, and Hi5.8 oz (165g)

with a Listed 5 A DC fuse in the supply circuit.

“H” and “P” models.

POWER SUPPLY

Page 12 of the GarrettCom S14 user manual — POWER SUPPLY
Page 12 · click to enlarge
Page 12

24V DC internal (range of 18 to 36V DC)

GarrettCom S14 — POWER SUPPLY diagram (page 12)
Fig. 4
GarrettCom S14 — POWER SUPPLY diagram (page 12)
Fig. 5

Input: 120vac at 60 Hz for “d” models, 240vac at 50Hz for “i” models that have IEC320

Input100-240V AC at 47-63Hz, for “-Hd” high temp., 100-240V AC at 47-63Hz “-for
Input100-240V AC at 47-63Hz, for “-Pd” high temp. 100-240V AC at 47-63Hz, “-Pi”

Hi” models that have IEC320 power connector built-in the PS unit.

models that have IEC320 power connector built-in the PS unit.

power connector built-in the PS unit. Out put- 12vdc, 1 Amps

block for +, -, ground. The 12V DC jack is also present.

DC to unit12V DC, 2.5mm jack, center +ve, 6ft. cord

Power Supply ( Direct DC ): built-in screw terminal

12V DC internal (range of 8.0 to 15V DC),

Out put- 12vdc, 1.25 Amps

Out put- 12vdc, 2 Amps

Page 13 of the GarrettCom S14 user manual — POWER SUPPLY
Page 13 · click to enlarge
Page 13

female. Three RJ-45 ports provided in front, and one on the rear. Supports shielded

GarrettCom S14 — POWER SUPPLY diagram (page 13)
Fig. 6

(STP) and unshielded (UTP) Cat 3, 4, 5 cable. For POE pass-through option on H

RJ-45 PortAuto-cross(MDIX), 100BASE-TX and 10BASE-T:shielded 8-pin

10/100: = 100Mbps; OFF = 10 Mbps LK/ACT: Steady On for LINK with no traffic, blinking indicates port

LED Indicators (Dual- front and end, port #4 has front only)

F/HON = full-duplex, OFF = half-duplex
POWERSteady On when power applied

is transmitting / receiving.

Power Consumption: 3 watts typical, 4 watts max.

-48V DC internal (range of 36 to 60V DC) t.

and P models, request quote.

Port Connectors:

Page 14 of the GarrettCom S14 user manual — POWER SUPPLY
Page 14 · click to enlarge
Page 14

IEC61850 EMC and Operating Conditions Class C for Power Substations

UL Listed (UL 60950), cUL, CE, Emissions meet FCC Part 15, Class A.

Rack-mount optionMC14-TRAY, see http://www.garrettcom.com/mc_tray.htm

Mean Tine Between Failure (MTBF) – 15+ years, Telcordia (Bellcore) Method

H & P modelsIEEE P1613 Env. Std for Electric Power Substations
DIN-Rail mounting optionModel # DIN-RAIL MC2 (see Section 3.4)
P modelNEMA TS-2 and TEES for traffic control equipment
P modeldesigned for UL 2043 above-the-ceiling installation

Metal Mounting clips for panel mounting: included

Agency Approvals and Standard Compliance:

Mounting option for S14 Family of Switches:

NEBS L3 and ETSI compliant

Page 15 of the GarrettCom S14 user manual — POWER SUPPLY
Page 15 · click to enlarge
Page 15
WarrantyThree years, return to factory Made in USA
Page 16 of the GarrettCom S14 user manual — 1.2 Summary of models and descriptions:
Page 16 · click to enlarge
Page 16

S14P-24VDC = Same as S14P-12VDC model, except Ext. AC Premium power supply not included

S14-d,i = four 10/100 RJ-45 ports Switch, for office and wiring closet env., ext. AC Pwr Supply

S14P-Pd, Pi = ,Premium rated, four 10/100 RJ-45 ports Switch, for un-controlled(outdoor) env.

S14H-12VDC = Same as S14H model, except Ext. AC Hardened power supply not included

S14P-12VDC = Same as S14P-Pd, Pi, except ext. AC Premium Power Supply is not included.

DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one S14-Series Switch

S14H-Hd, Hi = Hardened, four 10/100 RJ-45 ports Switch, Factory floor, Int. 8-15VDC,

Int. 8 to 15V terminal block, Ext. AC Premium-rated Power Supply included.

S14HR-24VDC = Same as S14H-24VDC model, but includes DIN-RAIL-MC2 option.

S14PR-24VDC = Same as S14P-24VDC model, but includes DIN-RAIL-MC2 option.

MC14-TRAY = 19” Rack-mount tray for 14-series Switch models, up to 16 units

S14H-24VDC = Same as S14H-12VDC model, except for 24VDC power input

S14H-48VDC = Same as S14H-24VDC model, except for -48VDC power input.

S14P-48VDC = Same as S14P-24VDC model, except for -48VDC input

1.2 Summary of models and descriptions:

Ext. AC Hardened power supply included .

Page 17 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 17 · click to enlarge
Page 17

product; notify the carrier immediately of any damage which you believe occurred during

1 User Guide, i.e., this manual (continued next page)

This section describes S14-Series models, including appearance, features and

shipment or delivery. Inspect the contents of this package for any signs of damage and

2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this

1 External Power Supply, (for S14, S14H, S14P), (d, i model only)

1 set Metal panel mounting clips and screws, 2 each

1 Magnum S14-Series Convenient Switch Unit

ensure that the items listed below are included.

2.0 INTRODUCTION

This package should contain:

typical applications.

Page 18 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 18 · click to enlarge
Page 18

rated (outdoor) versions. Extra features for heavy-duty and extended temperature operation

return the unit use the original shipping container. Refer to Section 5 Troubleshooting, for

Remove the Magnum S14-Series Switch from the shipping container. Be sure to keep the

ranges are included selectively in the Hardened factory-floor and Premium-rated outdoor

anywhere” Magnum S14 Switch is a versatile and handy solution, and can provide it in a

application environments, with regular (office), Hardened (factory floor), and Premium-

models. Input power may be AC, or DC at 12V, 24V or –48V, providing a selection for

office or for heavy duty industrial applications. This selection of models offers the best

In the event there are items missing or damaged contact your supplier. If you need to

For any user who needs a small chunk of Ethernet connectivity, a 4-port “go

2.2 Product Description The Magnum S14 family of Convenient Switches covers the full range of

shipping container should you need to ship the unit at a later date.

price / value unit for each user and installation.

convenient compact package.

specific return procedures.

Page 19 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 19 · click to enlarge
Page 19

Fig2.1a. Magnum S14, Front view (three RJ-45 ports on Front

Fig2.2a. Magnum S14, Rear view (one RJ-45 port on rear

GarrettCom S14 — 2.0 INTRODUCTION diagram (page 19)
Fig. 7

Fig 2.1a

side) · GarrettCom Magnum S14 · Convenient Switch

Page 20 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 20 · click to enlarge
Page 20

cooling is featured. Operation may be in 0° to 50°C ambient temperature. The units can be

unit features a sealed metal case which is also used as a heat sink. No air inflow is required

mounted securely on a closet wall or metal cabinet, or by using the metal panel mounting

rugged metal case for extended temperature industrial applications. The S14H Hardened

closet environments, uses an external AC power supply. A metal case with convection

models are built with high-grade components and use special thermal techniques and a

for cooling, so the S14H resists dust, dirt, moisture, smoke and insects, and is above-the-

The Yellow label, S14 shown above in regular-package units are for office and wiring

The orange-label Magnum S14H as shown above in Fig 2.2c, are

hardened units designed for factory floor and other industrial applications. The S14H

ceiling (plenum) rated. Choices of models for external AC or internal DC power are

clips included.

Page 21 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 21 · click to enlarge
Page 21

Fig2.2c. Magnum S14H, Rear view (one RJ-45 port and DC option on

available. Ambient temperature rating is up to –25°C to +60°C for any of the power input

Fig 2.2c- Magnum S14H, Front view (three RJ-45 ports on Front

GarrettCom S14 — 2.0 INTRODUCTION diagram (page 21)
Fig. 8

side of the unit, as shown in Fig.

rear side) as shown in Fig.

Fig 2.2d

GarrettCom S14 — 2.0 INTRODUCTION diagram (page 21)
Fig. 9

types, AC or DC.

Fig 2.2c

Show 4 more labels / short text on this page
GarrettCom S14 · Left Side View · GarrettCom Magnum S14H · Hardened Convenient Switch
Page 22 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 22 · click to enlarge
Page 22

extended temperature components, the S14P uses similar thermal

options include panel-mounting, DIN-rail, or rack-mount tray.

outdoor applications. Specially designed with premium-grade

techniques as the S14H hardened units for cooling. Mounting

Ambient temperature rating is –40°C to +75°C for any of the

The red-label Magnum S14P, as shown in Fig. 2.2e, is a

premium rated unit suitable for temperature un-controlled

Choices of models for external AC or internal DC powers

power input types, AC or DC.

are available.

GarrettCom S14 — 2.0 INTRODUCTION diagram (page 22)
Fig. 10

Premium Rated Convenient Switch

Fig. 2.2e

GarrettCom Magnum S14P

Page 23 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 23 · click to enlarge
Page 23

The Magnum S14-Series chassis houses one main PC board. The power supply is

an external AC unit or internal DC via a screw terminal block. The front side of the chassis

has three twisted-pair switched ports and one port is provided on the rear side. All the four

Dual LEDs indicate operating status of ports may be viewed from any direction,

indicators for the unit to validate that the unit is turned ON. For each port, there are Link

whereas the end LEDs mounted next to ports indicate (LK/Act) as LA1, LA2, LA3, LA4

for each of the four ports. 10/100 (ON for 100Mbps), and full/half duplex (F/H is ON for

ports of the S14-Series convenient switch support auto-cross (MDIX), and perform the

and are mounted on the top as well as end for convenience. There are power (PWR)

and Activity (LK/ACT) LEDs indicating traffic and mounted on the top of the unit,

2.3 Magnum S14-Series, with four (RJ-45) Copper ports

auto-cross in the auto-negotiation mode only.

full duplex) indicators for port # 2.

Page 24 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 24 · click to enlarge
Page 24

The external DC power plug connector or “jack” is in the right rear of the chassis.

Port #2 has the capability to configure that port as “FF” Full-Fixed for connecting

Each frame (or packet) is loaded into the Switch’s memory and inspected before forwarding

Use care in changing the switch position as the switch is small and fragile. See section 4.4.

can occur. This technique ensures that all forwarded frames are of a valid length and have

the 100Mb Full Duplex ports, or “A” to connect with an auto-negotiating port. Port #2 is

controlled by the manually-selectable slide-switch (FF-A), mounted underneath the port.

The Magnum S14-Series Convenient Switches are store-and-forward switches.

the correct CRC, i.e., are good packets. This eliminates the propagation of bad packets,

The internal DC input terminal block is also provided on the rear side of the unit.

enabling all of the available bandwidth to be used for valid information.

2.4 Frame Buffering and Latency

Page 25 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 25 · click to enlarge
Page 25

When the Switch detects that its free buffer queue space is low, the Switch sends

While other switching technologies such as "cut-through" or "express" impose

minimal frame latency, they will also permit bad frames to propagate out to the Ethernet

there is no way to filter frames with a bad CRC (the entire frame must be present in order

traffic congestion, especially at peak activity. Since collisions and bad packets are more

industry standard (full-duplex only) PAUSE packets out to the devices sending packets to

which allows a traffic catch-up to occur without dropping packets. Then, normal packet

which are a result of late collisions, to be forwarded to add to the network traffic. Since

for CRC to be calculated), the result of indiscriminate cut-through forwarding is greater

cause “flow control”. This tells the sending devices to temporarily stop sending traffic,

segments connected. The "cut-through" technique permits collision fragment frames,

likely when traffic is heavy, the result of store-and-forward operation is that more

bandwidth is available for good packets when the traffic load is greatest.

Page 26 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 26 · click to enlarge
Page 26

from entering by forcing a collision signal on all receiving half-duplex ports in order to stop

buffering and processing resumes. This flow-control sequence occurs in a small fraction of

speed types, and the length of the frame is a variable here as it is with all store-and-forward

Another feature implemented in Magnum S14-Series Convenient Switches is a

collision-based flow-control mechanism (when operating at half-duplex only). When the

switches. For 10 Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the

Switch detects that its free buffer queue space is low, the Switch prevents more frames

The latency (the time the frame spends in the Switch before it is sent along or

forwarded to its destination) of the S14-Series Convenient Switches varies with the port-

a second and is transparent to an observer. See Section 4.6 for additional details.

latency is 15 microseconds plus the packet time at 10 Mb. For 100Mb-to-100Mb

forwarding, the latency is 5 microseconds plus the packet time at 100Mb.

incoming traffic.

Page 27 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 27 · click to enlarge
Page 27

domains. Internal address tables are self-learning. All ports are auto-cross.

switching in a convenient and compact package that fits right into the site.

Where a small chunk of Ethernet connectivity is needed to connect edge

devices into the LAN, the Magnum S14-Series Switches provide 10/100

- Red-label, premium rated for un-controlled temperatures, outdoors

forwarding those packets from each domain that are needed on the other

Each S14-Series Convenient Switch is equipped with two sets (front and

side) of LEDs to provide status information when viewed at any angle or

„ Installation is “Plug and Play”, operation is transparent to software

2.5 Features and Benefits „ Small 4-port 10/100 Switch unit for edge-of-network applications

The Magnum S14-Series Switches operate as a LAN switch, only

mounting arrangement, rack-mount, DIN-Rail, or panel-mount.

„ Two sets of LEDs for viewing status from any angle.

„ Three models for three application environments

- Orange-label, Hardened for the factory floor.

- Yellow-label for the office and wiring closet

Page 28 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 28 · click to enlarge
Page 28

The 12V DC jack is present on DC-input models, so that the unit can operate

environments or high EMI noise sites; e.g industrial or outdoor applications.

S14-Series power input may be a variety of types, external AC and internal

from an external AC PS, or from DC applied to the terminal block, either or

convenience to move the unit from a test lab out to the factory floor.

Featuring a compact metal case, Magnum S14-Series can be installed in minimal

durability and noise immunity, even when placed in extended temperature

space in rack-mount MC14-TRAY, on DIN-Rail (optional), or panel-mounted.

both present. Dual-source power may increase availability, or be

S14-Series are packaged in a rugged sheet metal enclosures to ensure

„ AC and DC Power Supplies with extended temperature ratings

DC at 12V, 24V, or -48VDC. AC may be at extreme temperatures.

„ Efficient Compact design, for all-purpose convenient mounting

„ DC-input models can operate as dual-source

„ Rugged metal case, Industrial grade

Page 29 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 29 · click to enlarge
Page 29

compact Magnum S14-series 10/100 Mbps switch functions support a mixed environment

ports provides bandwidth for high performance. Port #1 (on the back end) is typically ised

Example 1. S14’s-In this example, the Magnum S14 Convenient Switch is used to serve a

Switch unit fits in any environment where users need to add a few RJ-45 ports to a LAN

of 10 Mbps and 100Mbps users, and the switching full / half duplex capability on all four

for an up-stream connection. When expansion is needed, add another S14 and connect it

2.6 Applications for office S14-Series With the three tier “YOR” hardness ratings, Yellow for “office”, Orange for

“Hardened”, Red for “Premium rated (outdoor)”, the Magnum S-14 Series Convenient

challenging industrial applications easier, more economical and more-reliable. The

small office in a factory with multi-servers, print server, internet access and mixed-

quickly and cost effectively. The edge-of–the-network connectivity product makes

into port #1 with twisted pair cabling, to add 3 more ports..

Page 30 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 30 · click to enlarge
Page 30
GarrettCom S14 — 2.0 INTRODUCTION diagram (page 30)
Fig. 11

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

expandiing solution for the non-stopping network demand

S14 Convenient Switches used as a useful & reliable

W W W . G a r r e t t C o m . C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

Page 31 of the GarrettCom S14 user manual — 2.0 INTRODUCTION
Page 31 · click to enlarge
Page 31

speed at any time without affecting network operation or impacting other users. The multi-

economically. Various features included MDIX, plug-n-play, Din-Rail mountings and dual

Example 2. S14HsIn this application of Industrial environments, where in a expanding

are typically used where 10/100BASE-T networking equipment is being installed in highly

(such as print servers) run at 10 Mbps. High performance users need a high bandwidth up-

controlled by the Industrial Engineering crews. The hardened version of Magnum S14Hs

speed requirements. The users operate at 100Mb as well as at 10 Mb, and utility devices

link for access to a central LAN and central file servers. Any attached node can change

controlled temp environment and required a effective and economical solution to satisfy

of Industrial network environment, the new PLC units are deployed on all the present

network and need a Ethernet port to carry the data to the main workstation for being

LEDs make this compact and convenient switch a very effective solution for this

functional S14 Convenient switches provide this solution very efficiently and

requirement.

Page 32 of the GarrettCom S14 user manual — PLC
Page 32 · click to enlarge
Page 32
GarrettCom S14 — PLC diagram (page 32)
Fig. 12

this need. Built with high-grade components and efficient thermal techniques of cooling,

and equipped with wide variety of options of AC and DC power supply,

S14H Convenient Switches provided a secure economical

solution for expanding Industrial network

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PLC

W W W . G a r r e t t C o m . C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

Page 33 of the GarrettCom S14 user manual — PLC
Page 33 · click to enlarge
Page 33

experiencing a need to scale its LAN quickly and cost effectively. With its half / full duplex

controllable industrial applications. The S14H Switches act as a network edge connectivity

The Magnum S14Ps fits very well in high temperature locations (control rooms)

environment of 10 Mbps and 100Mbps users and devices un-conditionally. The switching

each copper-cable user-access point. The 10/100 dual-speed functions, to support a mixed

the cost-effective Magnum S14Hs Convenient Switches easily qualified to use in highly

switching capability, the S14Ps provides a very economical high bandwidth solution at

capability on all ports provides bandwidth for high performance. The ruggedness of the

S14Ps steel case and the high reliability of the design compliments the temperature

controlled packaging to provide an exceptional Ethernet product.

unit to satisfy ongoing needs very efficiently and economically.

Example 3S14Ps
Page 34 of the GarrettCom S14 user manual — PLC
Page 34 · click to enlarge
Page 34
GarrettCom S14 — PLC diagram (page 34)
Fig. 13

S14P Convenient Switches provided a secure dependable,

reliable solution for un-controlled temp. environment

M a g n u m m P 6 2

W W W . G a r r e t t C o m . C o m

M a g n u m m P 6 2

Page 35 of the GarrettCom S14 user manual — PLC
Page 35 · click to enlarge
Page 35

connectivity requirement in a harsh temperature environment, mounted above the

dependable, reliable and economical solution for any temperature un-controlled

ceiling in the building. The ongoing demand of growing network can be easily

In this example, the extended temperature rated S14Ps takes care of the LAN

met by this sleek designed convenient Switch. The steel enclosure and wide

selections of DC power input qualifies the Magnum S14Ps to provide a

location environments.

Page 36 of the GarrettCom S14 user manual — 3.0 INSTALLATION
Page 36 · click to enlarge
Page 36

installed in almost any location. Metal mounting clips and screws are included for a rugged

Secure attachment of mounting

associated cabling. Make sure the unit is installed in a location that is easily accessible to

This section describes the installation of the Magnum S14-Series Convenient

installation location is dependent upon the physical layout of the Ethernet network and

and secure mounting in any orientation. An option DIN-Rail bracket is available.

Installation of the Magnum S14-Series Switches is a simple procedure. The

clips for Panel-

store and forward switch easily take care of the

network. The compact and lightweight design

of the Magnum S-Series allows it to be easily

3.1 Locating the Convenient Switch Unit All the S14-series Switches operate in

transparent half-and full-duplex mode. The

network traffic and can be used as a useful

Switches, including location, mountings,

economical tool to expand the existing

power supply and media connection.

3.0 INSTALLATION

Page 37 of the GarrettCom S14 user manual — Secure attachment of mounting
Page 37 · click to enlarge
Page 37
GarrettCom S14 — Secure attachment of mounting diagram (page 37)
Fig. 14 · Secure attachment of mounting

For 19” rack-mounting of Magnum S14-series Convenient Switches, a rack-mount tray is

green Power (PWR) Led must turn ON, when power is applied through the internal DC

an AC power outlet or power strip, and where convection cooling is not inhibited. The

input 12V, 24V or –48V DC or external AC through 9V DC jack.

3.2 MC14-TRAY for Rack Mounting of S14-Series Switches

Convenient Switches along with

with either fiber or BNC cable in

mounted with their RJ-45 port

and DC power jack in the back,

available, MC14-TRAY. The

Media Converter units are

the front. Any mix of the

Convenient Switches, Media

Page 38 of the GarrettCom S14 user manual — Secure attachment of mounting
Page 38 · click to enlarge
Page 38

Converters may be placed on a tray, up to a maximum of 16 units. (The mounting spaces of

typical installation of the model MC14-TRAY, 19” rack-mount tray will hold a few (often

bottom-front hold the Media Converters firmly in place. The beveled-top edge of the units

permits the LEDs of each unit to be viewed for operational status, even when the units are

Mounting the mix-match of 10Mbps and 100Mbps Media Converters and the S14-Series

the MC14-TRAY are specific to the “S14”-series, and do not permit other models). A

three to eight) S14-series Convenient Switches, with their power supplies plugged into

power strips (not included) in the rear area of the tray. Metal mounting screws in the

3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media Converters

Switches together in 19” rack-mount tray. These models comes with built-in common

The MC14-TR+ PS9 and MC14-TR+PS9X2 are another option available for Rack

universal AC power supply rated at 55 watts at 50°C ambient, 12VDC output, and

very close together.

Page 39 of the GarrettCom S14 user manual — Secure attachment of mounting
Page 39 · click to enlarge
Page 39

the MC14 -TR models are specific to the

(The MC mounting spaces of

Magnum S14-Series 10Mbps (FT14 and

TB14) and 100Mb (14E) series, and do

supply. These models are equipped with auto-ranging AC input to the power supplies for

The side-view picture shown

TR+PS9X2. The MC14-TR+PS9X2 Model has two groups of eight units per power

supporting up to 10 Switches for MC14-TR+PS9 and 16 units S14-Series for MC14-

here (above) is an example of an

models to be put in the tray).

use worldwide.

GarrettCom S14 — Secure attachment of mounting diagram (page 39)
Fig. 15 · Secure attachment of mounting

not permit other

Page 40 of the GarrettCom S14 user manual — Secure attachment of mounting
Page 40 · click to enlarge
Page 40

installation of the model MC14-TR+PS9, 19” rack-mount tray, holding a few S14-Series ,

into the built-in common AC power supply in the rear area of the tray. (PS units that come

10Mbps FT14’s and 100Mb 14E Media Converters, each with their power input plugged

Metal mounting screws in the bottom-front hold each of the media converters

GarrettCom S14 — Secure attachment of mounting diagram (page 40)
Fig. 16 · Secure attachment of mounting

secure in the tray, separately removable for service. The dual LEDs permit viewing

operating status of the S14-Sereis Convenient

environments, are also available for DIN-Rail

mounting in an enclosure having DIN Rails.

3.4 DIN-Rail mounting option The Magnum S14HR & S14PR

Convenient Switches, designed for use in

The metal DIN-Rail mounting

“Factory Floor” Industrial Ethernet

with the MC’s are not used).

Switches from any angle.

Page 41 of the GarrettCom S14 user manual — Secure attachment of mounting
Page 41 · click to enlarge
Page 41

DIN-RAIL-MC2. It comes with four screws to attach the bracket to the MC unit.

The Rail clip is spring-loaded with a pull-up latch at the top for easy “snap-on” attachment

Magnum S14-Series Switches are power-efficient and can work with an external

AC power supply. Magnum S14-Series require a nominal 12VDC input (range 8 to 15V,

see Specifications) at the jack in the rear. The extended temperature –Hd version is used

The Magnum S14 Models with “HR” have 24VDC power, and have the DIN-

hardware is optional and needs to be ordered as a separate item, e.g. Model #

A Magnum S14H is shown alongside the DIN-Rail-MC2 bracket

Rail-MC2 bracket included and assembled with the MC unit at the factory.

3.5 Power Requirements, Power Supply Types for S14-Series Switches

for heavy duty and industrial applications, up to 55`C ambient.

and removal.

Page 42 of the GarrettCom S14 user manual — 12VDC 24VDC -48VDC
Page 42 · click to enlarge
Page 42

The 12V DC power input has a plug of 2.5mm, center +ve , with 6 ft. cord. All the AC

power supply designed to be used with UL listed Class II power supplies and the detail

The S14-Series are designed to provide reliable operation, withstand higher temperature

environments, and provide the Direct DC power choices to the user to deploy in

12VDC 24VDC -48VDC

info is being provided in Technical Specifications Section 1.1.

uncontrolled temperature environments.

Page 43 of the GarrettCom S14 user manual — 12VDC 24VDC -48VDC
Page 43 · click to enlarge
Page 43

The Internal 12V DC (8 – 15V DC) has a built-in terminal block for +, -, ground.

only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like).

DC and the –48V DC is provided in the Technical Specifications Section 1.1.

temperature power supplies are numerous and your choice needs to be called out

The 9V DC jack is also present. Detail information about the 12 VDC, the 24V

The various models of Direct DC power type and extended ambient

GarrettCom S14 — 12VDC 24VDC -48VDC diagram (page 43)
Fig. 17

3.6 Powering the S14H & S14P (DC internal) with 12V, 24V or –48VDC power

supply, and have built-in screw terminals for

secure attachment of the power leads. Three

reliably equipped with an Direct DC power

Each Magnum S14H/S14P is

on your order.

input

Page 44 of the GarrettCom S14 user manual — 18 – 36V DC (24V DC)
Page 44 · click to enlarge
Page 44

12VDC, 24VDC or -48VDC power. DC power input may be chosen for high-availability.

into temperature uncontrolled environments, rated at –40`C to +75`C. The DC jack is also

The extended temperature capability of the Direct DC-powered S14P’s can go

present and optionally can be used with an external P-rated AC power supply to provide

models support a range of power input types. The three model choices are for use with

GNDTerminal for “earth” or ground wire connection to the S14H chassis

36 – 60V DC (-48V DC)

Input Voltage8 - 15V DC (12V DC)

18 – 36V DC (24V DC)

DC Power Terminals“+”, “-”, floating

“dual source” power input.

Page 45 of the GarrettCom S14 user manual — 36 – 60V DC (-48V DC)
Page 45 · click to enlarge
Page 45
GarrettCom S14 — 36 – 60V DC (-48V DC) diagram (page 45)
Fig. 18

3.7 S14H, DC-powered, -48VDC, 24VDC and 9VDC Installation

Power Consumption: 3 watts typical, 4 watts max.

0.4 amp max.(24V DC)

0.2 amp max.(-48V DC)

12VDC leads) to the Direct DC power terminal

terminal block on the Magnum S14H is located

on the left side of the unit and is equipped with

converter (as shown in Figure above). The DC

connection of the -48VDC leads (or 24VDC,

block on the Magnum S14H hardened media

three (3) screw-down lead posts. The power

Input current0.8 amp.(12V DC)

This section describes the proper

Page 46 of the GarrettCom S14 user manual — 36 – 60V DC (-48V DC)
Page 46 · click to enlarge
Page 46

terminals are identified as positive (+) and negative (-), and they are floating inside the unit

so that either of the terminal may be grounded by the user if desired. The chassis is “earth”

The connection procedure is straightforward. Simply insert the DC leads to the

S14H’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND)

optional; it connects to the S14H chassis. Ensure that each lead is securely tightened from

and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead

will connect to the post labeled “+ve” and the rest to the “-ve”.

When power is applied, the green PWR LED will illuminate.

The GND can be hooked up at the last.

the top, as shown here.

or ground (GND).

Page 47 of the GarrettCom S14 user manual — 36 – 60V DC (-48V DC)
Page 47 · click to enlarge
Page 47

either 10 and 100Mbps. Note that the auto-cross function does not operate, if the

mixed-speed network, since S14-series switch ports are auto-cross(MDIX) for

The Magnum S14-Series Convenient Switches can be connected to only one

media type with two different speed i.e. 100BASE-TX and 10BASE-T. CAT 5 cables

Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45

and 100Mbps) be used whenever possible in order to provide flexibility in a

should be used when making 100BASE-TX connections. When the ports are used as

Twisted Pair (CAT 5) 100BASE-TX RJ-45

10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for

Media IEEE Standard Connector

port is fixed or not supporting auto-negotiation.

unshielded twisted pair cabling is 100 meters (328 ft).

3.8 Connecting Twisted Pair (RJ-45 ports)

Page 48 of the GarrettCom S14 user manual — 36 – 60V DC (-48V DC)
Page 48 · click to enlarge
Page 48

The following procedure describes how to connect a 10BASE-T or 100BASE-TX

3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded)

twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and

does not help, ensure that the cable is connected properly and that the device on the

1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded,
2. Connect the other end of the cable to the corresponding device. 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established. If this
4. For Port # 1 or 1SW, if the LINK LED is not illuminated, move the switch which has a cross-over or up-link for linking to another hub or Switch.

either unshielded or shielded cables and wiring may be used.

other end is powered and is not defective.

shielded twisted pair cables.

Page 49 of the GarrettCom S14 user manual — 4.0 OPERATION
Page 49 · click to enlarge
Page 49

Fast Link Pulse (FLP) coding for the 100BASE-TX signaling system. When connecting a

10BASE-T). When 100Mb operation is agreed and in use, the 10/100 LED is illuminated

NIC to the S14-Sereis, it may be necessary to reload the NIC drivers on the user device if

The Magnum S14-Series Convenient Switches provide four switched

ports(three ports in the front and one on the rear). The architecture supports a dual speed

properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the

The copper ports of Magnum S14-Sereis Convenient Switches will function

the NIC has been communicating with a protocol other than 100BASE-TX (such as

3.8.2 Connections to NICs which support Auto-Negotiation, RJ-45 ports

switching environment, with auto-negotiation capability.

4.1 Dual-Speed Functionality, and Switching

steady ON and is OFF, if 10 Mbps traffic.

4.0 OPERATION

Page 50 of the GarrettCom S14 user manual — 4.0 OPERATION
Page 50 · click to enlarge
Page 50

The switched RJ-45 ports are full-duplex and auto-sensing for speed. (See section

“communicate with” 100Mbps users as well as 100Mbps domain. Similarly, the 100Mbps

traffic obeys the rules of 100Mbps Ethernet, and can communicate with 10 Mb domain too.

configuring to be done at installation or for maintenance. The internal functions of both are

the same port segment will be filtered, constraining them to one port and relieving the rest

Each time a packet arrives on one of the switched ports, the decision is taken to

either filter or to forward the packet. Packets whose source and destination addresses on

2.2). When the connected device is 10 Mbps, the S14s obeys all the rules of 10 Mbps

Ethernet configurations. The 10 Mbps users share a 10 Mbps traffic domain, and can

Magnum S14-Series units are plug-and-play devices. There is no software

Switching, Filtering and Forwarding

described below.

Page 51 of the GarrettCom S14 user manual — 4.0 OPERATION
Page 51 · click to enlarge
Page 51

and are suitable for use in large networks. They are self-learning, so that as nodes are added

The Magnum S14-Series units have address table capacity of 2K node addresses,

or removed or moved from one segment to another, the S14-Series automatically keeps up

ports where it is not needed. Packets needed for maintaining the operation of the network

The Magnum S14-Series Convenient Switches operate in the store-and-forward

of the network from processing them. A packet whose destination address is on another

port segment will be forwarded to the appropriate port, and will not be sent to the other

switching mode, which eliminates bad packets and enables peak performance to be

(such as occasional multi-cast packets) are forwarded to all ports.

achieved when there is heavy traffic on the network.

with node locations.

Switching, Address Learning

Page 52 of the GarrettCom S14 user manual — 4.0 OPERATION
Page 52 · click to enlarge
Page 52

An address-aging algorithm causes least-used addresses to fall out in favor of new

When a RJ-45 cable connection is made, and each time a LINK is enabled, auto-

speed, and the device at the other end of the cable should similarly advertise / respond and

negotiation mode for speed in 10BASE-T and 100BASE-TX modes. The MDIX does the

both sides will agree to the speed being used. Depending upon the device connected, this

negotiation takes place. The P80F or P80C advertises its capability for 10 or 100 Mbps

auto-cross only under the Auto-negotiation mode, and will not take effect if the port is

4.2 Auto-cross (MDIX),Auto-negotiation and Speed-sensing All the four RJ-45 ports independently support auto-cross (MDIX) in auto-

frequently-used addresses. To reset the address buffer, cycle power down-and-up.

will result in agreement to operate at either 10 Mbps or 100Mbps speed.

fixed. Operation is according to the IEEE 802.3u standard.

Page 53 of the GarrettCom S14 user manual — 4.0 OPERATION
Page 53 · click to enlarge
Page 53

LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will turn

off in the event connectivity is lost between the ends of the twisted pair segment

represented by LA1, LA2, LA3, & LA4. (Steady On or steady Off indicates no

or a loss of power occurs in the unit or remote device. The Link ports are also

10/100 Steady ON for 100Mb speed, OFF for 10Mb speed per port

F/H Steady ON for Full duplex mode, OFF for half duplex per port

4.4 Dual LEDs, Front-panel and side-panel (Magnum S14-Series) LED Description

PWR Illuminates GREEN to indicate power applied.

Receive Activity).

Page 54 of the GarrettCom S14 user manual — 5.0 TROUBLESHOOTING
Page 54 · click to enlarge
Page 54

Should problems develop during installation or operation, this section is intended

to help locate, identify and correct these types of problems. Please follow the suggestions

not performing as expected, do not attempt to repair the unit; instead contact your supplier

consistently high performance in all network environments. The installation of Magnum

S14-Series 10/100 Mb/s Switches is a straightforward procedure (see INSTALLATION,

procedures described in this section or if the Magnum S14-Series 10/100 Mb/s Switch is

listed below prior to contacting your supplier. However, if you are unsure of the

All Magnum Ethernet products are designed to provide reliability and

Section 3.0); the operation is also straightforward and is discussed in Section 4.

for assistance or contact GarrettCom Customer Support.

5.0 TROUBLESHOOTING

Page 55 of the GarrettCom S14 user manual — 5.0 TROUBLESHOOTING
Page 55 · click to enlarge
Page 55

the Installation Section of the applicable chapter of this manual. Also check to

during installation. (About 90% of network downtime can be attributed to wiring

device is replaced with a known good device. Verify whether or not the problem

is corrected. If not, go to Step 5 below. If the problem is corrected, the Magnum

connected and the cables/wires have not been crimped or in some way impaired

5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to

Series unit. Be certain that each AC power cord is plugged into a functioning

3. Make sure that an AC power cord is properly attached to each Magnum S14-

electrical outlet. Use the PWR LEDs to verify each unit is receiving power.

S14-Series 10/100 Mb/s switch product, it is recommended that the problem

2. Check the cables and connectors to ensure that they have been properly
4. If the problem is isolated to a network device other than the Magnum

S14-Series Switch and its associated cables are functioning properly.

make sure that the various components of the network are interoperable.

and connector problems.)

Page 56 of the GarrettCom S14 user manual — 5.0 TROUBLESHOOTING
Page 56 · click to enlarge
Page 56
5. If the problem continues after completing Step 4 above, contact your supplier of
2. An accurate list of GarrettCom product model(s)involved, with serial number(s).

including Convenient computers, workstations, terminals and printers; plus, the

Include the date(s) that you purchased the products from your supplier.

d. Any particular application that, when used, appears to create the problem;

3. It is useful to include other network equipment models and related hardware,

the Magnum S14-Series 10/100 Mb/s Switch unit or if unknown, contact

GarrettCom, Inc by fax, phone or email (support@garrettcom.com) for

1. A complete description of the problem, including the following points:

5.2 When Calling for Assistance Please be prepared to provide the following information.

c. The components involved in the problem;

a. The nature and duration of the problem;

various network media types being used.

b. Situations when the problem occurs;

assistance.

Page 57 of the GarrettCom S14 user manual — 5.0 TROUBLESHOOTING
Page 57 · click to enlarge
Page 57

the occurrence of the problem. Any changes to system administration procedures

438-9071 during business hours in California or email to support@garrettcom.com). When calling, please have the following information readily available:

4. A record of changes that have been made to your network configuration prior to

5.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization

(RMA) number. To obtain an RMA number, call GarrettCom Customer Service at (510)

Failure symptoms, including a full description of the problem.

Name and phone number of your contact person.

Packing List Number (or Sales Order Number)

Name of your company / institution

Serial Number (or Invoice Number)

should all be noted in this record.

Your shipping address · Date of installation · Product name

Page 58 of the GarrettCom S14 user manual — 5.0 TROUBLESHOOTING
Page 58 · click to enlarge
Page 58
1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet

GarrettCom will carefully test and evaluate all returned products, will repair products that

are under warranty at no charge, and will return the warranty-repaired units to the sender

details). However, if the problem or condition causing the return cannot be duplicated by

GarrettCom reserves the right to charge for the testing of non-defective units

under warranty. Testing and repair of product that is not under warranty will result in a

5.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions:

with shipping charges prepaid (see Warranty Information, Appendix A, for complete

or bag for shipping protection. ( You may retain all connectors and this

GarrettCom, the unit will be returned as:

No Problem Found.

Installation Guide.)

customer (user) charge.

Page 59 of the GarrettCom S14 user manual — 5.0 TROUBLESHOOTING
Page 59 · click to enlarge
Page 59
2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.
3. GarrettCom is not responsible for your return shipping charges.

This material may cause electro-static shock damage to the unit.

213 Hammond Ave.

Attn.: Customer Service

GarrettCom, Inc.

4. Ship the package to:

Fremont, CA 94539

Page 60 of the GarrettCom S14 user manual — APPENDIX A: WARRANTY INFORMATION
Page 60 · click to enlarge
Page 60

components in the products that prove to be defective at no charge other than shipping and

has been damaged by misuse, misapplication, or as a result of service or modification other

Please complete the warranty card as this acts as a product registration, and mail

This warranty will not be effective if, in the opinion of GarrettCom, the product

GarrettCom reserves the right to make a charge for handling and inspecting any

GarrettCom, Inc. warrants its products to be free from defects in materials and

workmanship for a period of three (3) years from the date of shipment by GarrettCom.

During this warranty period, GarrettCom will repair or, at its option, replace

handling, provided that the product is returned pre-paid to GarrettCom.

product returned for warranty repair which turns out not to be faulty.

APPENDIX A: WARRANTY INFORMATION

it to GarrettCom within two weeks of your purchase.

than by GarrettCom.

Ask about the GarrettCom S14

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom S14

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom S14 manual PDF

60 pages·584 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…