Installation and User Guide
(A member of Converter Switch family)



S14 Convenient Switch Installation and User Guide (09/04)
GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch and Converter
render all warranties null and void. If problems are experienced with Magnum
Copyright © 2004 GarrettCom, Inc. All rights reserved. No part of this publication may
Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.
S14, 10/100 Mb/s Switches products, consult Section 5, Troubleshooting, of
user serviceable parts. Attempted service by unauthorized personnel shall
be reproduced without prior written permission from GarrettCom, Inc.
NEBS is a registered trademark of Telcordia Technologies
UL is a registered trademark of Underwriters Laboratories
Ethernet is a trademark of Xerox Corporation
Printed in the United States of America.
this User Guide.
Trademarks

S14 Convenient Switch Installation and User Guide (09/04)
This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to take whatever
Radio Frequency Interference Statement
measures may be required to correct the interference.
Federal Communications Commission

S14 Convenient Switch Installation and User Guide (09/04)
Please use the mailing address, phone and fax numbers and email address listed below:
GarrettCom, Inc.
213 Hammond Ave. Fremont, CA 94539
Fax (510) 438-9072 · Contacting GarrettCom, Inc



S14 Convenient Switch Installation and User Guide (09/04)
3.7 S14H, DC-powered, -48VDC, 24VDC and 9VDC Installation 38
3.8 Connecting Twisted Pair (RJ-45 ports) 40
3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5) 41
3.8.2 Connections to NICs which support Auto-Negotiation 42
4.1 Dual-Speed Functionality, and Switching 42
4.2 Auto-cross (MDIX),Auto-negotiation and Speed-sensing 45
4.3 Dual LEDs, Front-panel and side-panel (Magnum S14-Series) 46
5.1 Before Calling for Assistance 48
5.2 When Calling for Assistance 49
5.3 Return Material Authorization (RMA) Procedure 50
5.4 Shipping and Packaging Information 51

S14 Convenient Switch Installation and User Guide (09/04)
06/04: Small revision of the Agency Approvals Rev A 03/04: Initial release of this user manual for the S14 Converter Switch
GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or
10/04: Small edit and updates on power supply option. 09/04: Small edit and updates on UL.
model offerings without notice.

Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.
Filter / Forwarding Rate from 100Mbps ports: 148,800 pps max
100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3u
When a port is operating at 100Mbps:
When a port is operating at 10 Mbps:
1.1 Technical Specifications
Ports Performance · Network Standards

Latency (not including packet time): 100 to 10 Mbps: 5µs 10 to 100Mbps: 5µs Path Delay Value: 50 BT on all ports
Ambient Temperature (S14): 32ºF to 104ºF (0ºC to 40ºC) (S14H): -13ºF to 140ºF (-25ºC to 60ºC)
-40ºF to 149ºF (-40ºC to 85ºC)
Long term per independent agency tests (UL)
Long term per independent agency tests (UL)
10BASE-T (Unshielded twisted pair) - 100 m (328 ft)
100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
Short term per IEC Type tests
Maximum Ethernet Segment (or Domain) Lengths
Address buffer age-out time: 300 sec.
Operating Environment

S14, S14H, and S14P: 3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x 2.5 cm)
-58ºF to 212ºF (-50ºC to 100ºC)
Short term per IEC Type tests
(S14P) model to -40ºC
Conformal Coating (optional) Humidity protection
Enclosure: Rugged sheet metal (Steel).
altitude.

These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked
500mA).When connected to a 48 V centralized dc source these products shall be provided
“Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output
voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to
Power input (8-15)V DC, jack is 2.5mm center +ve , with 6ft. cord
UL listed class II Power Supply, ( AC External):
with a Listed 5 A DC fuse in the supply circuit.
“H” and “P” models.

24V DC internal (range of 18 to 36V DC)


Input: 120vac at 60 Hz for “d” models, 240vac at 50Hz for “i” models that have IEC320
Hi” models that have IEC320 power connector built-in the PS unit.
models that have IEC320 power connector built-in the PS unit.
power connector built-in the PS unit. Out put- 12vdc, 1 Amps
block for +, -, ground. The 12V DC jack is also present.
Power Supply ( Direct DC ): built-in screw terminal
12V DC internal (range of 8.0 to 15V DC),
Out put- 12vdc, 1.25 Amps
Out put- 12vdc, 2 Amps

female. Three RJ-45 ports provided in front, and one on the rear. Supports shielded

(STP) and unshielded (UTP) Cat 3, 4, 5 cable. For POE pass-through option on H
10/100: = 100Mbps; OFF = 10 Mbps LK/ACT: Steady On for LINK with no traffic, blinking indicates port
LED Indicators (Dual- front and end, port #4 has front only)
is transmitting / receiving.
Power Consumption: 3 watts typical, 4 watts max.
-48V DC internal (range of 36 to 60V DC) t.
and P models, request quote.
Port Connectors:

IEC61850 EMC and Operating Conditions Class C for Power Substations
UL Listed (UL 60950), cUL, CE, Emissions meet FCC Part 15, Class A.
Mean Tine Between Failure (MTBF) – 15+ years, Telcordia (Bellcore) Method
Metal Mounting clips for panel mounting: included
Agency Approvals and Standard Compliance:
Mounting option for S14 Family of Switches:
NEBS L3 and ETSI compliant


S14P-24VDC = Same as S14P-12VDC model, except Ext. AC Premium power supply not included
S14-d,i = four 10/100 RJ-45 ports Switch, for office and wiring closet env., ext. AC Pwr Supply
S14P-Pd, Pi = ,Premium rated, four 10/100 RJ-45 ports Switch, for un-controlled(outdoor) env.
S14H-12VDC = Same as S14H model, except Ext. AC Hardened power supply not included
S14P-12VDC = Same as S14P-Pd, Pi, except ext. AC Premium Power Supply is not included.
DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one S14-Series Switch
S14H-Hd, Hi = Hardened, four 10/100 RJ-45 ports Switch, Factory floor, Int. 8-15VDC,
Int. 8 to 15V terminal block, Ext. AC Premium-rated Power Supply included.
S14HR-24VDC = Same as S14H-24VDC model, but includes DIN-RAIL-MC2 option.
S14PR-24VDC = Same as S14P-24VDC model, but includes DIN-RAIL-MC2 option.
MC14-TRAY = 19” Rack-mount tray for 14-series Switch models, up to 16 units
S14H-24VDC = Same as S14H-12VDC model, except for 24VDC power input
S14H-48VDC = Same as S14H-24VDC model, except for -48VDC power input.
S14P-48VDC = Same as S14P-24VDC model, except for -48VDC input
Ext. AC Hardened power supply included .

product; notify the carrier immediately of any damage which you believe occurred during
1 User Guide, i.e., this manual (continued next page)
This section describes S14-Series models, including appearance, features and
shipment or delivery. Inspect the contents of this package for any signs of damage and
2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this
1 External Power Supply, (for S14, S14H, S14P), (d, i model only)
1 set Metal panel mounting clips and screws, 2 each
1 Magnum S14-Series Convenient Switch Unit
ensure that the items listed below are included.
This package should contain:
typical applications.

rated (outdoor) versions. Extra features for heavy-duty and extended temperature operation
return the unit use the original shipping container. Refer to Section 5 Troubleshooting, for
Remove the Magnum S14-Series Switch from the shipping container. Be sure to keep the
ranges are included selectively in the Hardened factory-floor and Premium-rated outdoor
anywhere” Magnum S14 Switch is a versatile and handy solution, and can provide it in a
application environments, with regular (office), Hardened (factory floor), and Premium-
models. Input power may be AC, or DC at 12V, 24V or –48V, providing a selection for
office or for heavy duty industrial applications. This selection of models offers the best
In the event there are items missing or damaged contact your supplier. If you need to
For any user who needs a small chunk of Ethernet connectivity, a 4-port “go
2.2 Product Description The Magnum S14 family of Convenient Switches covers the full range of
shipping container should you need to ship the unit at a later date.
price / value unit for each user and installation.
convenient compact package.
specific return procedures.

Fig2.1a. Magnum S14, Front view (three RJ-45 ports on Front
Fig2.2a. Magnum S14, Rear view (one RJ-45 port on rear

Fig 2.1a
side) · GarrettCom Magnum S14 · Convenient Switch

cooling is featured. Operation may be in 0° to 50°C ambient temperature. The units can be
unit features a sealed metal case which is also used as a heat sink. No air inflow is required
mounted securely on a closet wall or metal cabinet, or by using the metal panel mounting
rugged metal case for extended temperature industrial applications. The S14H Hardened
closet environments, uses an external AC power supply. A metal case with convection
models are built with high-grade components and use special thermal techniques and a
for cooling, so the S14H resists dust, dirt, moisture, smoke and insects, and is above-the-
The Yellow label, S14 shown above in regular-package units are for office and wiring
The orange-label Magnum S14H as shown above in Fig 2.2c, are
hardened units designed for factory floor and other industrial applications. The S14H
ceiling (plenum) rated. Choices of models for external AC or internal DC power are
clips included.

Fig2.2c. Magnum S14H, Rear view (one RJ-45 port and DC option on
available. Ambient temperature rating is up to –25°C to +60°C for any of the power input
Fig 2.2c- Magnum S14H, Front view (three RJ-45 ports on Front

side of the unit, as shown in Fig.
rear side) as shown in Fig.
Fig 2.2d

types, AC or DC.
Fig 2.2c

extended temperature components, the S14P uses similar thermal
options include panel-mounting, DIN-rail, or rack-mount tray.
outdoor applications. Specially designed with premium-grade
techniques as the S14H hardened units for cooling. Mounting
Ambient temperature rating is –40°C to +75°C for any of the
The red-label Magnum S14P, as shown in Fig. 2.2e, is a
premium rated unit suitable for temperature un-controlled
Choices of models for external AC or internal DC powers
power input types, AC or DC.
are available.

Premium Rated Convenient Switch
Fig. 2.2e
GarrettCom Magnum S14P

The Magnum S14-Series chassis houses one main PC board. The power supply is
an external AC unit or internal DC via a screw terminal block. The front side of the chassis
has three twisted-pair switched ports and one port is provided on the rear side. All the four
Dual LEDs indicate operating status of ports may be viewed from any direction,
indicators for the unit to validate that the unit is turned ON. For each port, there are Link
whereas the end LEDs mounted next to ports indicate (LK/Act) as LA1, LA2, LA3, LA4
for each of the four ports. 10/100 (ON for 100Mbps), and full/half duplex (F/H is ON for
ports of the S14-Series convenient switch support auto-cross (MDIX), and perform the
and are mounted on the top as well as end for convenience. There are power (PWR)
and Activity (LK/ACT) LEDs indicating traffic and mounted on the top of the unit,
2.3 Magnum S14-Series, with four (RJ-45) Copper ports
auto-cross in the auto-negotiation mode only.
full duplex) indicators for port # 2.

The external DC power plug connector or “jack” is in the right rear of the chassis.
Port #2 has the capability to configure that port as “FF” Full-Fixed for connecting
Each frame (or packet) is loaded into the Switch’s memory and inspected before forwarding
Use care in changing the switch position as the switch is small and fragile. See section 4.4.
can occur. This technique ensures that all forwarded frames are of a valid length and have
the 100Mb Full Duplex ports, or “A” to connect with an auto-negotiating port. Port #2 is
controlled by the manually-selectable slide-switch (FF-A), mounted underneath the port.
The Magnum S14-Series Convenient Switches are store-and-forward switches.
the correct CRC, i.e., are good packets. This eliminates the propagation of bad packets,
The internal DC input terminal block is also provided on the rear side of the unit.
enabling all of the available bandwidth to be used for valid information.
2.4 Frame Buffering and Latency

When the Switch detects that its free buffer queue space is low, the Switch sends
While other switching technologies such as "cut-through" or "express" impose
minimal frame latency, they will also permit bad frames to propagate out to the Ethernet
there is no way to filter frames with a bad CRC (the entire frame must be present in order
traffic congestion, especially at peak activity. Since collisions and bad packets are more
industry standard (full-duplex only) PAUSE packets out to the devices sending packets to
which allows a traffic catch-up to occur without dropping packets. Then, normal packet
which are a result of late collisions, to be forwarded to add to the network traffic. Since
for CRC to be calculated), the result of indiscriminate cut-through forwarding is greater
cause “flow control”. This tells the sending devices to temporarily stop sending traffic,
segments connected. The "cut-through" technique permits collision fragment frames,
likely when traffic is heavy, the result of store-and-forward operation is that more
bandwidth is available for good packets when the traffic load is greatest.

from entering by forcing a collision signal on all receiving half-duplex ports in order to stop
buffering and processing resumes. This flow-control sequence occurs in a small fraction of
speed types, and the length of the frame is a variable here as it is with all store-and-forward
Another feature implemented in Magnum S14-Series Convenient Switches is a
collision-based flow-control mechanism (when operating at half-duplex only). When the
switches. For 10 Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the
Switch detects that its free buffer queue space is low, the Switch prevents more frames
The latency (the time the frame spends in the Switch before it is sent along or
forwarded to its destination) of the S14-Series Convenient Switches varies with the port-
a second and is transparent to an observer. See Section 4.6 for additional details.
latency is 15 microseconds plus the packet time at 10 Mb. For 100Mb-to-100Mb
forwarding, the latency is 5 microseconds plus the packet time at 100Mb.
incoming traffic.

domains. Internal address tables are self-learning. All ports are auto-cross.
switching in a convenient and compact package that fits right into the site.
Where a small chunk of Ethernet connectivity is needed to connect edge
devices into the LAN, the Magnum S14-Series Switches provide 10/100
- Red-label, premium rated for un-controlled temperatures, outdoors
forwarding those packets from each domain that are needed on the other
Each S14-Series Convenient Switch is equipped with two sets (front and
side) of LEDs to provide status information when viewed at any angle or
Installation is “Plug and Play”, operation is transparent to software
2.5 Features and Benefits Small 4-port 10/100 Switch unit for edge-of-network applications
The Magnum S14-Series Switches operate as a LAN switch, only
mounting arrangement, rack-mount, DIN-Rail, or panel-mount.
Two sets of LEDs for viewing status from any angle.
Three models for three application environments
- Orange-label, Hardened for the factory floor.
- Yellow-label for the office and wiring closet

The 12V DC jack is present on DC-input models, so that the unit can operate
environments or high EMI noise sites; e.g industrial or outdoor applications.
S14-Series power input may be a variety of types, external AC and internal
from an external AC PS, or from DC applied to the terminal block, either or
convenience to move the unit from a test lab out to the factory floor.
Featuring a compact metal case, Magnum S14-Series can be installed in minimal
durability and noise immunity, even when placed in extended temperature
space in rack-mount MC14-TRAY, on DIN-Rail (optional), or panel-mounted.
both present. Dual-source power may increase availability, or be
S14-Series are packaged in a rugged sheet metal enclosures to ensure
AC and DC Power Supplies with extended temperature ratings
DC at 12V, 24V, or -48VDC. AC may be at extreme temperatures.
Efficient Compact design, for all-purpose convenient mounting
DC-input models can operate as dual-source
Rugged metal case, Industrial grade

compact Magnum S14-series 10/100 Mbps switch functions support a mixed environment
ports provides bandwidth for high performance. Port #1 (on the back end) is typically ised
Example 1. S14’s-In this example, the Magnum S14 Convenient Switch is used to serve a
Switch unit fits in any environment where users need to add a few RJ-45 ports to a LAN
of 10 Mbps and 100Mbps users, and the switching full / half duplex capability on all four
for an up-stream connection. When expansion is needed, add another S14 and connect it
2.6 Applications for office S14-Series With the three tier “YOR” hardness ratings, Yellow for “office”, Orange for
“Hardened”, Red for “Premium rated (outdoor)”, the Magnum S-14 Series Convenient
challenging industrial applications easier, more economical and more-reliable. The
small office in a factory with multi-servers, print server, internet access and mixed-
quickly and cost effectively. The edge-of–the-network connectivity product makes
into port #1 with twisted pair cabling, to add 3 more ports..


PORTS 1SW 2SW 3 4 5 6 7 8
PORTS 1SW 2SW 3 4 5 6 7 8
expandiing solution for the non-stopping network demand
S14 Convenient Switches used as a useful & reliable
W W W . G a r r e t t C o m . C o m
PORTS 1SW 2SW 3 4 5 6 7 8
PORTS 1SW 2SW 3 4 5 6 7 8

speed at any time without affecting network operation or impacting other users. The multi-
economically. Various features included MDIX, plug-n-play, Din-Rail mountings and dual
are typically used where 10/100BASE-T networking equipment is being installed in highly
(such as print servers) run at 10 Mbps. High performance users need a high bandwidth up-
controlled by the Industrial Engineering crews. The hardened version of Magnum S14Hs
speed requirements. The users operate at 100Mb as well as at 10 Mb, and utility devices
link for access to a central LAN and central file servers. Any attached node can change
controlled temp environment and required a effective and economical solution to satisfy
of Industrial network environment, the new PLC units are deployed on all the present
network and need a Ethernet port to carry the data to the main workstation for being
LEDs make this compact and convenient switch a very effective solution for this
functional S14 Convenient switches provide this solution very efficiently and
requirement.


this need. Built with high-grade components and efficient thermal techniques of cooling,
and equipped with wide variety of options of AC and DC power supply,
S14H Convenient Switches provided a secure economical
solution for expanding Industrial network
PORTS 1SW 2SW 3 4 5 6 7 8
PORTS 1SW 2SW 3 4 5 6 7 8
W W W . G a r r e t t C o m . C o m
PORTS 1SW 2SW 3 4 5 6 7 8
PORTS 1SW 2SW 3 4 5 6 7 8

experiencing a need to scale its LAN quickly and cost effectively. With its half / full duplex
controllable industrial applications. The S14H Switches act as a network edge connectivity
The Magnum S14Ps fits very well in high temperature locations (control rooms)
environment of 10 Mbps and 100Mbps users and devices un-conditionally. The switching
each copper-cable user-access point. The 10/100 dual-speed functions, to support a mixed
the cost-effective Magnum S14Hs Convenient Switches easily qualified to use in highly
switching capability, the S14Ps provides a very economical high bandwidth solution at
capability on all ports provides bandwidth for high performance. The ruggedness of the
S14Ps steel case and the high reliability of the design compliments the temperature
controlled packaging to provide an exceptional Ethernet product.
unit to satisfy ongoing needs very efficiently and economically.


S14P Convenient Switches provided a secure dependable,
reliable solution for un-controlled temp. environment
M a g n u m m P 6 2
W W W . G a r r e t t C o m . C o m
M a g n u m m P 6 2

connectivity requirement in a harsh temperature environment, mounted above the
dependable, reliable and economical solution for any temperature un-controlled
ceiling in the building. The ongoing demand of growing network can be easily
In this example, the extended temperature rated S14Ps takes care of the LAN
met by this sleek designed convenient Switch. The steel enclosure and wide
selections of DC power input qualifies the Magnum S14Ps to provide a
location environments.

installed in almost any location. Metal mounting clips and screws are included for a rugged
associated cabling. Make sure the unit is installed in a location that is easily accessible to
This section describes the installation of the Magnum S14-Series Convenient
installation location is dependent upon the physical layout of the Ethernet network and
and secure mounting in any orientation. An option DIN-Rail bracket is available.
Installation of the Magnum S14-Series Switches is a simple procedure. The
store and forward switch easily take care of the
network. The compact and lightweight design
of the Magnum S-Series allows it to be easily
3.1 Locating the Convenient Switch Unit All the S14-series Switches operate in
transparent half-and full-duplex mode. The
network traffic and can be used as a useful
Switches, including location, mountings,
economical tool to expand the existing
power supply and media connection.


For 19” rack-mounting of Magnum S14-series Convenient Switches, a rack-mount tray is
green Power (PWR) Led must turn ON, when power is applied through the internal DC
an AC power outlet or power strip, and where convection cooling is not inhibited. The
input 12V, 24V or –48V DC or external AC through 9V DC jack.
3.2 MC14-TRAY for Rack Mounting of S14-Series Switches
Convenient Switches along with
with either fiber or BNC cable in
mounted with their RJ-45 port
and DC power jack in the back,
available, MC14-TRAY. The
Media Converter units are
the front. Any mix of the
Convenient Switches, Media

Converters may be placed on a tray, up to a maximum of 16 units. (The mounting spaces of
typical installation of the model MC14-TRAY, 19” rack-mount tray will hold a few (often
bottom-front hold the Media Converters firmly in place. The beveled-top edge of the units
permits the LEDs of each unit to be viewed for operational status, even when the units are
Mounting the mix-match of 10Mbps and 100Mbps Media Converters and the S14-Series
the MC14-TRAY are specific to the “S14”-series, and do not permit other models). A
three to eight) S14-series Convenient Switches, with their power supplies plugged into
power strips (not included) in the rear area of the tray. Metal mounting screws in the
3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting Media Converters
Switches together in 19” rack-mount tray. These models comes with built-in common
The MC14-TR+ PS9 and MC14-TR+PS9X2 are another option available for Rack
universal AC power supply rated at 55 watts at 50°C ambient, 12VDC output, and
very close together.

the MC14 -TR models are specific to the
(The MC mounting spaces of
Magnum S14-Series 10Mbps (FT14 and
TB14) and 100Mb (14E) series, and do
supply. These models are equipped with auto-ranging AC input to the power supplies for
The side-view picture shown
TR+PS9X2. The MC14-TR+PS9X2 Model has two groups of eight units per power
supporting up to 10 Switches for MC14-TR+PS9 and 16 units S14-Series for MC14-
here (above) is an example of an
models to be put in the tray).
use worldwide.

not permit other

installation of the model MC14-TR+PS9, 19” rack-mount tray, holding a few S14-Series ,
into the built-in common AC power supply in the rear area of the tray. (PS units that come
10Mbps FT14’s and 100Mb 14E Media Converters, each with their power input plugged
Metal mounting screws in the bottom-front hold each of the media converters

secure in the tray, separately removable for service. The dual LEDs permit viewing
operating status of the S14-Sereis Convenient
environments, are also available for DIN-Rail
mounting in an enclosure having DIN Rails.
3.4 DIN-Rail mounting option The Magnum S14HR & S14PR
Convenient Switches, designed for use in
The metal DIN-Rail mounting
“Factory Floor” Industrial Ethernet
with the MC’s are not used).
Switches from any angle.

DIN-RAIL-MC2. It comes with four screws to attach the bracket to the MC unit.
The Rail clip is spring-loaded with a pull-up latch at the top for easy “snap-on” attachment
Magnum S14-Series Switches are power-efficient and can work with an external
AC power supply. Magnum S14-Series require a nominal 12VDC input (range 8 to 15V,
see Specifications) at the jack in the rear. The extended temperature –Hd version is used
The Magnum S14 Models with “HR” have 24VDC power, and have the DIN-
hardware is optional and needs to be ordered as a separate item, e.g. Model #
A Magnum S14H is shown alongside the DIN-Rail-MC2 bracket
Rail-MC2 bracket included and assembled with the MC unit at the factory.
3.5 Power Requirements, Power Supply Types for S14-Series Switches
for heavy duty and industrial applications, up to 55`C ambient.
and removal.

The 12V DC power input has a plug of 2.5mm, center +ve , with 6 ft. cord. All the AC
power supply designed to be used with UL listed Class II power supplies and the detail
The S14-Series are designed to provide reliable operation, withstand higher temperature
environments, and provide the Direct DC power choices to the user to deploy in
info is being provided in Technical Specifications Section 1.1.
uncontrolled temperature environments.

The Internal 12V DC (8 – 15V DC) has a built-in terminal block for +, -, ground.
only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like).
DC and the –48V DC is provided in the Technical Specifications Section 1.1.
temperature power supplies are numerous and your choice needs to be called out
The 9V DC jack is also present. Detail information about the 12 VDC, the 24V
The various models of Direct DC power type and extended ambient

3.6 Powering the S14H & S14P (DC internal) with 12V, 24V or –48VDC power
supply, and have built-in screw terminals for
secure attachment of the power leads. Three
reliably equipped with an Direct DC power
Each Magnum S14H/S14P is
on your order.
input

12VDC, 24VDC or -48VDC power. DC power input may be chosen for high-availability.
into temperature uncontrolled environments, rated at –40`C to +75`C. The DC jack is also
The extended temperature capability of the Direct DC-powered S14P’s can go
present and optionally can be used with an external P-rated AC power supply to provide
models support a range of power input types. The three model choices are for use with
“dual source” power input.


3.7 S14H, DC-powered, -48VDC, 24VDC and 9VDC Installation
Power Consumption: 3 watts typical, 4 watts max.
0.4 amp max.(24V DC)
0.2 amp max.(-48V DC)
12VDC leads) to the Direct DC power terminal
terminal block on the Magnum S14H is located
on the left side of the unit and is equipped with
converter (as shown in Figure above). The DC
connection of the -48VDC leads (or 24VDC,
block on the Magnum S14H hardened media
three (3) screw-down lead posts. The power
This section describes the proper

terminals are identified as positive (+) and negative (-), and they are floating inside the unit
so that either of the terminal may be grounded by the user if desired. The chassis is “earth”
The connection procedure is straightforward. Simply insert the DC leads to the
S14H’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND)
optional; it connects to the S14H chassis. Ensure that each lead is securely tightened from
and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead
will connect to the post labeled “+ve” and the rest to the “-ve”.
When power is applied, the green PWR LED will illuminate.
The GND can be hooked up at the last.
the top, as shown here.
or ground (GND).

either 10 and 100Mbps. Note that the auto-cross function does not operate, if the
mixed-speed network, since S14-series switch ports are auto-cross(MDIX) for
The Magnum S14-Series Convenient Switches can be connected to only one
media type with two different speed i.e. 100BASE-TX and 10BASE-T. CAT 5 cables
Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45
and 100Mbps) be used whenever possible in order to provide flexibility in a
should be used when making 100BASE-TX connections. When the ports are used as
Twisted Pair (CAT 5) 100BASE-TX RJ-45
10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for
Media IEEE Standard Connector
port is fixed or not supporting auto-negotiation.
unshielded twisted pair cabling is 100 meters (328 ft).
3.8 Connecting Twisted Pair (RJ-45 ports)

The following procedure describes how to connect a 10BASE-T or 100BASE-TX
3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded)
twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and
does not help, ensure that the cable is connected properly and that the device on the
either unshielded or shielded cables and wiring may be used.
other end is powered and is not defective.
shielded twisted pair cables.

Fast Link Pulse (FLP) coding for the 100BASE-TX signaling system. When connecting a
10BASE-T). When 100Mb operation is agreed and in use, the 10/100 LED is illuminated
NIC to the S14-Sereis, it may be necessary to reload the NIC drivers on the user device if
The Magnum S14-Series Convenient Switches provide four switched
ports(three ports in the front and one on the rear). The architecture supports a dual speed
properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the
The copper ports of Magnum S14-Sereis Convenient Switches will function
the NIC has been communicating with a protocol other than 100BASE-TX (such as
3.8.2 Connections to NICs which support Auto-Negotiation, RJ-45 ports
switching environment, with auto-negotiation capability.
4.1 Dual-Speed Functionality, and Switching
steady ON and is OFF, if 10 Mbps traffic.

The switched RJ-45 ports are full-duplex and auto-sensing for speed. (See section
“communicate with” 100Mbps users as well as 100Mbps domain. Similarly, the 100Mbps
traffic obeys the rules of 100Mbps Ethernet, and can communicate with 10 Mb domain too.
configuring to be done at installation or for maintenance. The internal functions of both are
the same port segment will be filtered, constraining them to one port and relieving the rest
Each time a packet arrives on one of the switched ports, the decision is taken to
either filter or to forward the packet. Packets whose source and destination addresses on
2.2). When the connected device is 10 Mbps, the S14s obeys all the rules of 10 Mbps
Ethernet configurations. The 10 Mbps users share a 10 Mbps traffic domain, and can
Magnum S14-Series units are plug-and-play devices. There is no software
Switching, Filtering and Forwarding
described below.

and are suitable for use in large networks. They are self-learning, so that as nodes are added
The Magnum S14-Series units have address table capacity of 2K node addresses,
or removed or moved from one segment to another, the S14-Series automatically keeps up
ports where it is not needed. Packets needed for maintaining the operation of the network
The Magnum S14-Series Convenient Switches operate in the store-and-forward
of the network from processing them. A packet whose destination address is on another
port segment will be forwarded to the appropriate port, and will not be sent to the other
switching mode, which eliminates bad packets and enables peak performance to be
(such as occasional multi-cast packets) are forwarded to all ports.
achieved when there is heavy traffic on the network.
with node locations.
Switching, Address Learning

An address-aging algorithm causes least-used addresses to fall out in favor of new
When a RJ-45 cable connection is made, and each time a LINK is enabled, auto-
speed, and the device at the other end of the cable should similarly advertise / respond and
negotiation mode for speed in 10BASE-T and 100BASE-TX modes. The MDIX does the
both sides will agree to the speed being used. Depending upon the device connected, this
negotiation takes place. The P80F or P80C advertises its capability for 10 or 100 Mbps
auto-cross only under the Auto-negotiation mode, and will not take effect if the port is
4.2 Auto-cross (MDIX),Auto-negotiation and Speed-sensing All the four RJ-45 ports independently support auto-cross (MDIX) in auto-
frequently-used addresses. To reset the address buffer, cycle power down-and-up.
will result in agreement to operate at either 10 Mbps or 100Mbps speed.
fixed. Operation is according to the IEEE 802.3u standard.

LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will turn
off in the event connectivity is lost between the ends of the twisted pair segment
represented by LA1, LA2, LA3, & LA4. (Steady On or steady Off indicates no
or a loss of power occurs in the unit or remote device. The Link ports are also
10/100 Steady ON for 100Mb speed, OFF for 10Mb speed per port
F/H Steady ON for Full duplex mode, OFF for half duplex per port
4.4 Dual LEDs, Front-panel and side-panel (Magnum S14-Series) LED Description
PWR Illuminates GREEN to indicate power applied.
Receive Activity).

Should problems develop during installation or operation, this section is intended
to help locate, identify and correct these types of problems. Please follow the suggestions
not performing as expected, do not attempt to repair the unit; instead contact your supplier
consistently high performance in all network environments. The installation of Magnum
S14-Series 10/100 Mb/s Switches is a straightforward procedure (see INSTALLATION,
procedures described in this section or if the Magnum S14-Series 10/100 Mb/s Switch is
listed below prior to contacting your supplier. However, if you are unsure of the
All Magnum Ethernet products are designed to provide reliability and
Section 3.0); the operation is also straightforward and is discussed in Section 4.
for assistance or contact GarrettCom Customer Support.

the Installation Section of the applicable chapter of this manual. Also check to
during installation. (About 90% of network downtime can be attributed to wiring
device is replaced with a known good device. Verify whether or not the problem
is corrected. If not, go to Step 5 below. If the problem is corrected, the Magnum
connected and the cables/wires have not been crimped or in some way impaired
5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to
Series unit. Be certain that each AC power cord is plugged into a functioning
electrical outlet. Use the PWR LEDs to verify each unit is receiving power.
S14-Series 10/100 Mb/s switch product, it is recommended that the problem
S14-Series Switch and its associated cables are functioning properly.
make sure that the various components of the network are interoperable.
and connector problems.)

including Convenient computers, workstations, terminals and printers; plus, the
Include the date(s) that you purchased the products from your supplier.
d. Any particular application that, when used, appears to create the problem;
the Magnum S14-Series 10/100 Mb/s Switch unit or if unknown, contact
GarrettCom, Inc by fax, phone or email (support@garrettcom.com) for
5.2 When Calling for Assistance Please be prepared to provide the following information.
c. The components involved in the problem;
a. The nature and duration of the problem;
various network media types being used.
b. Situations when the problem occurs;
assistance.

the occurrence of the problem. Any changes to system administration procedures
438-9071 during business hours in California or email to support@garrettcom.com). When calling, please have the following information readily available:
5.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization
(RMA) number. To obtain an RMA number, call GarrettCom Customer Service at (510)
Failure symptoms, including a full description of the problem.
Name and phone number of your contact person.
Packing List Number (or Sales Order Number)
Name of your company / institution
Serial Number (or Invoice Number)
should all be noted in this record.
Your shipping address · Date of installation · Product name

GarrettCom will carefully test and evaluate all returned products, will repair products that
are under warranty at no charge, and will return the warranty-repaired units to the sender
details). However, if the problem or condition causing the return cannot be duplicated by
GarrettCom reserves the right to charge for the testing of non-defective units
under warranty. Testing and repair of product that is not under warranty will result in a
5.4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom, please follow these instructions:
with shipping charges prepaid (see Warranty Information, Appendix A, for complete
or bag for shipping protection. ( You may retain all connectors and this
GarrettCom, the unit will be returned as:
No Problem Found.
Installation Guide.)
customer (user) charge.

This material may cause electro-static shock damage to the unit.
213 Hammond Ave.
Attn.: Customer Service
GarrettCom, Inc.
Fremont, CA 94539

components in the products that prove to be defective at no charge other than shipping and
has been damaged by misuse, misapplication, or as a result of service or modification other
Please complete the warranty card as this acts as a product registration, and mail
This warranty will not be effective if, in the opinion of GarrettCom, the product
GarrettCom reserves the right to make a charge for handling and inspecting any
GarrettCom, Inc. warrants its products to be free from defects in materials and
workmanship for a period of three (3) years from the date of shipment by GarrettCom.
During this warranty period, GarrettCom will repair or, at its option, replace
handling, provided that the product is returned pre-paid to GarrettCom.
product returned for warranty repair which turns out not to be faulty.
it to GarrettCom within two weeks of your purchase.
than by GarrettCom.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.