(Including SC, ST and MTRJ ports, full/half duplex, mm and sgl. mode, standard Link Pass-through)
Media Converters



GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a
Installation and User Guide
UL is a registered trademark of Underwriters Laboratories
NEBS is a trademark of Telcordia Technologies
Ethernet is a trademark of Xerox Corporation
registered trademark of GarrettCom, Inc.
Trademarks

parts. Attempted service by unauthorized personnel shall render all warranties
null and void. If problems are experienced with Magnum 14E Media
Converters, consult Section 5, Troubleshooting, of this User Guide.
of this publication may be reproduced without prior written permission from
Copyright 2001 GarrettCom, Inc. All rights reserved. No part
Printed in the United States of America.
GarrettCom, Inc.

Please use the mailing address, phone and fax numbers and email address listed below:
47823 Westinghouse Drive Fremont, CA 94539
GarrettCom, Inc.
Fax (510) 438-9072 · Contacting GarrettCom, Inc

This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to take whatever
Radio Frequency Interference Statement
measures may be required to correct the interference.
Federal Communications Commission



was Garrett Communications). There are no changes to the content of the
Rev E 10/02 : Link-Pass-through feature updated in this revision.
Power Supply added in this revision.
Switch information added.
material at this time.
user manual.

200ns (20 bit-times) Path Delay Value (PDV) for conversion delay
Half- or Full-Duplex transparent, F/H auto-negotiation supported
Operating Environment:
1.1. Technical Specifications
Network Standards:
Performance:

100BASE-TX (twisted pair): 100 m (328 ft) 100BASE-FX Fiber optic, half-duplex: (multi-mode) 412 m (1350 ft) 100BASE-FX Fiber optic, full duplex: (multi-mode) 2.0 km (6,562 ft) 100BASE-FX Fiber optic, half-duplex: (single-mode) 412 m (1350 ft) 100BASE-FX Fiber optic, full duplex: (single-mode) 25 km (66k ft) 100BASE-FX Long Reach: Fiber optic, full duplex: (single -mode) 40 km (132k ft) Note: Magnum 14E Media Converters DO NOT support full length
shared Fast Ethernet segments. See Section 3.2 of this manual for
media lengths and shared segment distance calculations.
Power Input: 95 - 125 vac at 60 Hz for "-d" Models, 100 - 240 vac at 50 Hz for "-i" Models which have IEC power cable connector.
Maximum Standard Fast Ethernet Segment Lengths:
Power Supply (External):

MT-RJ-type, Small Form Factor (plug in): Multi-mode, 100BASE-FX
or for regular operation. See Section 4.4
Fiber, single-mode (25-Km and up):
Fiber, multi-mode (up to 2Km) :
Connectors:

LINK, Fiber port Steady ON when both attached cable segments are operational
at their respective other ends, blinking when receiving remote
Dimensions: 3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x 2.5 cm)
**Power Supply: 2.0 in x 2.0 in x 1.5 in (5.1 cm x 5.1 cm x 3.8 cm)
LED Indicators for the Magnum 14E (Dual, on front and on end) :
PWR Indicates unit is receiving DC power.
fault from the other end.
Enclosure: High strength sheet metal.
Packaging:

LINK, Copper port Steady ON when the attached cable segments are
operational at their respective other ends
RX/ACT Activity, blinking indicates port is receiving
UL Listed (UL 1950), cUL , CE Certified
Agency Approvals:

MC14-TR+ PS9 = 19” Rack-mount tray , support upto 10 units of 100Mbps 14E Fiber Media Converters,Uses 2U
Magnum 14E-SSCL-d Twisted pair to fiber ST, single mode 40km “Long Reach”, external 115vac, 60
MC14-TR+PS9X2 = Powered 19” Rack-mount tray for 100Mb, 14E (and 10Mbps, TF14 mix and match) Media
Converters, up to 16 units @ 9vdcs. Uses 2U rack space. Includes common multi-unit Power Supply for universal
Magnum 14E-SSC-d Twisted pair to fiber SC, single-mode std 25Km, ext. 230vac, 50 Hz PS
Magnum 14E-MT-RJ-d Twisted pair to fiber MT-RJ small form factor, ext. 115 vac, 60 Hz PS
Magnum 14E-SC-d Twisted pair to mm fiber SC, ext. 115 vac, 60Hz power supply
Magnum 14E-SC-i Twisted pair to mm fiber SC, ext. 230 vac, 50Hz power supply
Magnum 14E-ST-d Twisted pair to mm fiber ST, ext. 115 vac, 60Hz power supply
Magnum 14E-ST-i Twisted pair to mm fiber ST, ext. 230 vac, 50Hz power supply
Magnum 14E-MT-RJ-i Same as Magnum 14E-MT-RJ, but with ext.230 vac, 50 Hz PS
Magnum 14E-SSC-I Same as Magnum 14E-SSC, but with ext 230vac, 50 Hz PS
Magnum 14E-SSCL-i Same as Magnum 14E-SSCl, but with ext 230vac, 50 Hz PS
GarrettCom, Inc. reserves the right to change specifications, performance
rack space, has space for a few external PS units (which are part of the MC’s)
AC input, 55 watts at 9vdc, and power cabling for the MC’s
characteristics and/or model offerings without notice.
1.2 Ordering Information
Hz Power Supply · Model Number Description

This section describes the Magnum 14E Fast Ethernet Media Converters, including
Examine the shipping container for obvious damage prior to installing this product;
Inspect the contents of this package for any signs of damage and ensure that the items listed
notify the carrier of any damage which you believe occurred during shipment or delivery.
1 External Power Supply, either 115 vac 60 Hz or 230 vac 50 Hz
1 Magnum 14E Media Converter unit
2.1 Inspecting the Package and Product
appearance, features and possible applications.
This package should contain:
below are included.

to return the unit, use the original shipping container. Refer to Section 5, Troubleshooting, for
Remove the Magnum 14E Media Converter from the shipping container. Be sure to
In the event there are items missing or damaged, contact your supplier. If you need
validate the product warranty, please complete and return the enclosed Product Registration
keep the shipping container should you need to store or to ship the unit at a later date. To
1 Velcro Tape section, approximately 3 inches in length
1 User Guide (this manual) and Product Registration Card
1 Set of two (2) metal mounting clips, with screws
Card to GarrettCom, Inc. within two weeks of purchase.
specific return procedures.

very tight spaces. Media cables are easily attached. Magnum 14E Media Converters feature an
graceful way to incorporate fiber media into a 100BASE-TX Ethernet network. Each Magnum
14E supports both full- and half-duplex mode transparently so that an attached RJ-45 switch or
either (a) “AN” for auto-negotiation, where the 14E transmits applicable auto-negotiation Fast
Link Pulses (FLPs) from the RJ-45 port to the connected 10/100 switch port at Link-enable, or
Magnum 14E Media Converters are designed for quick and easy installation even in
switches, a manual AN/reg switch on the Magnum 14E allows the user to manually enable
Magnum 14E Fast Ethernet Media Converters offer a convenient, cost-effective and
hub operates at its highest performance level. For support of “N-way” auto-negotiating
up-link switch on the TX port to eliminate the need for a special cross-over cable when
(b) “reg” regular media converter mode, no auto-negotiation.

Magnum 14E Media Converters are designed to operate at high ambient temperatures
external power supply, 115vac 60Hz or 230vac 50Hz, plugs into a nearby AC wall socket or
power strip. Each 14E Media-Converter features a two full sets (front and side) of LEDs that
over an extended period, making them some of the most reliable in the industry. Their high-
Converters can be Velcro®-mounted on an office wall or the side of a desk or cabinet. The
strength fabricated metal packaging shields against Radio Frequency Interference (RFI) and
connecting the TX port to a switch or hub. Because of their compact size, Magnum Media
convey essential status information in any mounting arrangement. See Section 4.1, LED
Electromagnetic Interference (EMI), avoiding interference with other nearby electronic
Indicators, for LED function information.
devices.

The Magnum 14E units comply with the IEEE 802.3u (100BASE-TX and 100BASE-
FX) specification for 100 Mb/sec traffic via shielded (STP) or unshielded twisted pair (UTP)

14Es with ST integrates 100BASE-TX and FX networks, with fiber ST connector
standard in all 14E’s. Magnum 14E-ST models
are equipped with one multi-mode fiber-ST and
The Link Pass-Through feature is especially
desirable for use in managed networks, and is
one RJ-45 connector for connection into
100BASE-FX segments.
segments.
Twisted Pair · (ST-type) (100BASE-FX)

The Magnum 14E-SC comes in three models, with three different fiber transceivers.
Models are 14E-SC (multi-mode, 2Km), 14E-SSC (single-mode, 25Km) or 14E-SSCL (single-
(100BASE-FX)
14Es with SC integrate 100BASE-TX and FX networks, with fiber SC connectors.
TX RX
RX\ACT
FIBER TWISTED PAIR
RX/ACT
9VDC .3AMP
equipped with one fiber SC-type
Fast Ethernet network segments.
mode Long Reach, 40Km) are
port and one RJ-45 port for

transceivers. The Model 14E-MTRJ (multi-mode, 2Km), equipped with one fiber MTRJ-type
The Magnum 14E-MTRJ (SFF, small form factor) comes with multi-mode fiber
port and one RJ-45 port, connects into 100BASE-FX and 100BASE-TX compliant Fast
(100BASE-FX)
14Es with SC integrate 100BASE-TX and FX networks, with fiber MT-RJ connectors.
TX RX
RX\ACT
FIBER
TWISTED PAIR
RX/ACT
9VDC .3AMP
SFF MT-RJ connector is keyed so
that it can only be connected when
Ethernet network segments. The
the two fiber strands are correctly
positioned for transmit and
receive. See Section 3.4.3.

Magnum 14E Media Converters add signal timing delays of only 20 Bit Times
in a shared half-duplex segment, much less than a Class II (90 to 95 BT ), and
Magnum 14E’s support both full-duplex and half-duplex mode transparently,
can be used to attach fiber cables to TX ports with low distance loss in an
and are suited for use with 100Mb Ethernet switches supporting (or not
Magnum 14E Media Converters offer an ideal solution to quickly and
! Full-duplex or Half-duplex transparent, auto-negotiation support
inexpensively connect Twisted-Pair TX with Fiber FX cabling.
! Low PDV for Maximum Cable Lengths in Shared Segments
overall HDX collision domain.
supporting) auto-negotiation.
! Reduces Network Costs
2.3 Features and Benefits

Featuring a compact and lightweight metal case with an external power supply,
Magnum 14E Media Converters can be conveniently installed in minimal space.
Each 14E Media Converter is equipped with a two sets (front & side) of LEDs
connectors: ST, SC mm and sgl-mode, and MT-RJ SFF (small form-factor).
Models of the Magnum 14E’s are available with all of the popular fiber
to provide status information when viewed at any angle or mounting
! Link Pass-through is standard This feature, desired mainly in
managednetworks, is standard in all Magnum 14E’s.
! Choice of 100Mb Ethernet Fiber port connector types
! Two sets of LEDs for viewing status from any angle.
The MC14-TRAY provides optional rack-mounting.
arrangement, rack-mount Tray or wall-mount.
! Small, Compact, Lightweight Design

between different media types. Magnum 14E media converters provides an effective solution for
Magnum 14Es are typically used where new 10/100Mb switches or switching hubs with
auto-negotiating RJ-45 ports are being installed, and where full-duplex fiber segments (of up to
The primary function of a Magnum 14E Media Converter is to permit two different
media types to coexist within the same network by allowing data to be transmitted / received
a network environment where auto-negotiation is a primary concern for the attached devices.
They also support 100Mb half duplex or full duplex mode, transparent. Because of its auto-
negotiation feature, the Magnum 14E supports an attached “N-way” auto-negotiating RJ-45
switch or hub port, allowing it to operate at its highest performance level, i.e., full-duplex
2Km for multi-mode or 25Km to 40Km for single mode) are needed
100Mb/s.

Alternatively, a server with a full-duplex NIC may need to be connected via fiber to a 100Mb
to interconnect them with other 100Mb switches or switching hubs in distant wiring closets.
Two Magnum 14E’s provide connectivity for 100Mbps switches or hubs via fiber

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
switches or switching hubs with RJ-45 ports.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Magnum 14E

Where shared Fast Ethernet segments are used, such as with Fast Ethernet switches or
pair cable to fiber, allowing use of any available RJ-45 Fast Ethernet switched port with a new
“Auto-negotiation” and “reg” regular mode at the attached RJ-45 port, allowing flexibility with
In these and similar situations, the Magnum 14E conveniently converts the twisted
switching hubs with RJ-45 ports, it may be desirable to connect one or more servers or users
via fiber cable. Because of its manual AN/reg switch feature, the Magnum 14E supports both
It is necessary to calculate the PDV of the overall collision domain (see Section
or existing fiber cable. See Section 3.2.1 for cable distance calculation information.
the unit attached. See Section 3.4.3 for details on auto-negotiation support.
3.2.2) for proper operation of the Magnum 14E in HDX applications.

A typical Magnum 14E application is to convert copper media to fiber, with auto-

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
negotiation support for the attached device on the copper port.

accessible to an AC power outlet or power strip, and where convection cooling is not inhibited.
The compact and lightweight design of the Magnum 14E Media Converter allows it
This section describes the installation of the Magnum 14E Media Converters,
including location, segment distance calculation and media connection.
sure the unit is installed in a location that is easily
3.1 Locating the Media Converter Unit
mounting the unit on a vertical surface such as a
Ethernet network and associated cabling. Make
to be easily installed in most any location. A
Velcro strip and a set of two metal clips and
screws are included (either may be used) for
table-top or shelf. The installation location is
wall or cabinet, or for securing the unit on a
dependent upon the physical layout of the

MC14-TRAY. The Media Converter units are mounted with their DC power jack in the back,
For 19” rack-mounting of Magnum 14E Media Converter, a rack-mount tray is available,
and with the RJ-45 and the fiber ports in front. Any mix of the “14”-series 10Mb Media
3.2 MC14-TRAY for Rack Mounting of Magnum 14E Media Converters

Converters and 14Es may be placed on a tray, up to a maximum

power strips (not included) in the rear area of the tray. Metal mounting screws in the bottom-
of 16 units. (The mounting spaces of the MC14-TRAY are specific to the 10Mb “14”-series
A typical installation of the model MC14-TRAY, 19” rack-mount tray will hold a
few (often three to eight) 14E Media Converters, each with their power supply plugged into

and the 14E, and do not permit other models or other sizes to be put in the tray).

mount tray. These models comes with built-in common universal AC power supply rated at 55
two groups of eight units per power supply. These models are equipped with Auto-ranging AC
The MC14-TR+ PS9 and MC14-TR+PS9X2 are another option available for Rack
watts at 50C ambient, 9VDC output, and supporting up to 10 MC for MC14-TR+PS9 and 16
units of Fiber media converters for MC14-TR+PS9X2. The MC14-TR+PS9X2 Model has
10Mbps (TF14) and 100MB (14E) series, and do not permit other models or other sizes to be put in the tray).
Mounting the mix-match of 10Mbps and 100Mbps Media Converters together in 19” rack-
(The MC mounting spaces of the MC14 -TR models are specific to the Magnum
3.3 MC14-TR+PS9 & MC14-TR+PS9X2 for Rack Mounting 100Mbps Crossover
front hold the media converters firmly in place in the tray.
input to the power supplies for use worldwide.
Media Converters


separately removable for service. The dual LEDs permit viewing operating status of the Media
built-in common AC power supply in
The side-view picture shown here is
mount tray, holding a few 100Mbps
Metal mounting screws in
an example of an installation of the
14E Media Converters, each with their power input plugged into the
the rear area of the tray. (PS units
media converters secure in the tray,
model MC14-TR+PS9, 19” rack-
the bottom-front hold each of the
that come with the MC’s are not
Converters from any angle.
used).

Receiver Sensitivity and Transmitter Power are the parameters necessary to compute
duplex (standard Fast Ethernet) installations. Each of these situations are covered below in a
The following data has been collected from component manufacturer’s (HP’s and Siemens’)
The media distance considerations are quite different for full-duplex and for half-
the power budget. To calculate the power budget of different fiber media installations, the
where the “Cable Loss” for 62.5/125 and 50/125µm (m.m.) is 2.8 dB/km,
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
web sites and catalogs to provide guidance to network designers and installers.
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
and the “Cable Loss” for 100/140 (multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (single-mode) is 0.5 dB/km
3.4.1 Power Budget Calculations for Fiber Media
OPB (Optical Power Budget) = PT(min) - PR(min)
3.4 Calculating Segment Distances
following equations should be used:
separate section.


long distances (i.e., over approx. 400 meters) can be achieved only if the following factors are
-31 9.0 5.5 2.5 2.0 14 12 5 4
mode 25 (0.4) 1300 9/125 -15 -31 14 28 17.5 35
-31 9.0 5.5 2.5 2.0 14 12 5 4
mode 40 (0.4) 1300 9/125 -5 -34 27 54 32.5 65
14E-SSC 100Mb FX Single-
Std. Mode
14E- MST, MSC 100Mb FX Multi-
14E-MTRJ 100Mb FX Multi-
both applied:

not a factor. Specifically, fiber segments can be up to 2Km for multi-mode and up to 25Km for
Full-duplex ports, such as copper are found in switching hubs and some NICs, can
There may be only two nodes present on a full-duplex segment. Media distance rules are not
the same as for standard (half-duplex) Fast Ethernet because collision distance limitations are
receive and transmit signals simultaneously and do not experience collisions accordingly.
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
3.3.2 Segment Distances, Full-duplex for copper media (RJ-45) and fiber
equal external unit such as a FDX NIC) must be used, and
single mode (or 40Km for “Long Reach” single mode).
Attenuation.

overall segment length is calculated by adding together the segment lengths on both sides of the
Magnum 14E Media Converters. The figure below illustrates how a Magnum Media Converter
Segment length on each side of the 14E Media Converter is measured as a percentage
of the maximum allowable standard media distance for the given media type. The percentages,
The Magnum 14E, with full-duplex operation as a standard feature, can be used in
these applications. When installing the Magnum 14E in a full-duplex segment, it is important
to consider the combined overall segment length of both of the attached media types. The
is used to connect a multi-mode fiber (100BASE-FX) with a twisted pair (100BASE-T)
when added together, must not exceed 100%.
segment.

Media Distance Formula for Magnum 14E, full-duplex:
Where Y = The segment length on the other side of the Magnum 14E
Where X = The segment distance on one side of the Magnum 14E
Media Converter divided by the Standard Maximum
Media Converter divided by the Standard Maximum
Media Distance for that media cabling type, x 100%
Media Distance for that media type, x 100%

media (100 m) [10/100 x 100% = 10%]. The total of the two percentages (75% + 10%) is 85%,
ft). This is 10% of the maximum allowable distance for 100BASE-TX full-duplex twisted-pair
media (2000 m) [75/2000 x 100% = 75%]. The length of twisted pair Segment Y is 10m (33

above, the length of fiber Segment X is
maximum allowable distance for multi-
and 100BASE-FX Ethernet Media.
In the example figure shown
1500m (4920 ft). This is 75% of the
mode 100BASE-FX fiber full-duplex
which is allowable.
Twisted Pair · (ST-type) (100BASE-FX) · Connectivity between 100BASE-TX

fiber (100BASE-FX) with a twisted pair (100BASE-T) segment. In this example, the length of
media (100 m) [12/100 x 100% = 12%]. The total of the two percentages (57% + 12%) is 69%,
In another instance, a Magnum Media Converter is used to connect a single mode
fiber Segment X is 8500m (27,880 ft). This is 57% of the maximum allowable distance for
single mode 100BASE-FX fiber full-duplex media (15,000 m) [57/15,000 x 100% = 57%].
This is 12% of the maximum allowable distance for 100BASE-TX full-duplex twisted-pair
the percentages for all of the cabling lengths in the run must be added
The length of twisted pair Segment Y is 12m (40 ft).
together and must not exceed 100%.
which is allowable.

domain of the segment, including the 14E itself, repeaters and hubs present, and the lengths of
domain. When a node attempts to send a packet, it may hit another packet passing by, i.e., a
installing the Magnum 14E in a half-duplex segment, it is important to consider the collision
A collision domain is defined in the IEEE 802.3u standard as a cluster of network
Fast Ethernet shared bandwidth devices operate with multiple nodes in a traffic
devices that, regardless of topology, must be less than 512 BT (Bit Times) of signal delay
collision may occur. This is normal and does not cause a problem because the Ethernet
protocol provides for this situation and requires that the sender wait and try again. When
3.4.3 Segment Distances, Half-duplex mode
3.4.4 Collision Domain (PDV Calculations)
both of the attached media types.

devices in a single collision domain. Regardless of the actual network topology, the Collision
(PDV or Path Delay Value) in diameter between any two nodes. Nodes in a collision domain
are connected by means of a repeater or repeaters such that no bridging or switching devices
are present between any two nodes in the cluster. A Magnum 14E has a PDV of about eighty
Domain Diameter must be less than 512 BT (Bit Times). Bit Times are related to media type
Bit Times (20 BT), and this value must be included in the overall collision domain diameter
PDV calculations as applicable for the placement of the 14E in the topology of the collision
The Collision Domain Diameter is the length of the longest path between any two
as shown in Table 3.2.2a.
domain.
Collision Domain Diameter

3.4b shows typical Fast Ethernet device components and the associated BT delay. Note that
Fiber Optic 1.000 Shielded TP cable 1.112 Category 5 Cable 1.112 Category 4 Cable 1.140 *Worst case delays taken from IEEE Std 802.3u-1995, actual delays may be less for a particular cable. Contact your cable supplier for exact cable specifications.
Each shared Fast Ethernet network device also has an associated BT delay. Table
Media Type Round-trip delay in Bit Time per Meter (BT/m)
there is only one DTE pair associated with any device-to-device path.

domain diameter specification, the following formula should be applied to the worst case path
through the network. The worst case path is the path between the two Fast Ethernet devices
To determine whether a prospective network topology adheres to the collision
Component Round-trip delay in Bit Times (BT)
2 TX DTEs 100 2 FX DTEs 100 1 FX and 1 TX DTE 100 1 T4 and 1 TX or FX DTE 127 Class I Repeater 140 Class II Repeater with any
combination of TX and FX ports 92
*Worst case delays taken from IEEE Std 802.3u-1995.

BT and may be a value between 0 and 5. This margin can be used to accommodate unexpected
rule-of-thumb, a Class II Repeater has a PDV of about 90 to 95 BTs, and twisted-pair or fiber
IEEE 802.3u standard, this value must be less than 512 BT. The safety margin is specified in
Rules-of-thumb, while inexact, may be helpful in planning network topology. As a
PDV is the Path Delay Value of the worst case path. For the network to adhere to
delays, such as an extra long patch cable. A safety margin of at least 2 to 4 BT is
converter delays) + (DTE pair delays) + (safety margin)
(DTEs) which have the longest round trip delay time.
“Rules-of-thumb” Collision Domain Calculations
recommended.

cable distance to convert from TX media to fiber FX media, i.e., it consumes almost as much of
after allowing for a 14E and a length of fiber media indicates that the available fiber length will
(connected by a pair of Magnum 14Es on each end) can be obtained that will interconnect two
media has a PDV of about 1 BT per meter of length. The Magnum 14E has a PDV of 20 BT.
the available PDV as a Class II repeater. Since a 512BT collision domain will almost always
include at least one repeater and two media segments, the remaining amount of Bit Times left
be much less than the 412 meters that is the known maximum for fiber. Therefore, in shared
environments, Magnum 14E Media Converters will be of benefit when they allow the use of
fiber media, but not to gain distance by facilitating use of fiber media instead of twisted pair.
Therefore, in shared Fast Ethernet applications, the 14E uses about 80 meters of equivalent
100Mb hubs where the twisted pair cables to the user nodes are 10 meters in length.
As a sample calculation, consider the question of what fiber cable distance

length to be the 100 meters maximum for twisted pair media, and this would still leave about a
hundred BTs as a safety margin. In other words, use of 14Es and fiber in this case did not gain
It is obvious that using twisted pair wiring to connect the hubs would enable the interconnect
minus 10 BT for two short TP cables from the hubs to 14E’s leaves 202 BTs,
minus 20 BT for two 10-meter TP cables for hubs to users leaves 212 BTs,
minus 40 BT for two Magnum 14Es leaves 162 BTs for fiber cable,
512 = total available Bit Times in a collision domain diameter,
minus 100 BT for two DTEs on each end leaves 412 BTs,
minus 180 BT for two Class II repeaters leaves 232 BTs,
which indicates a fiber cable length of about 160 meters.
The solution is :

maximum of 30 meters (100 ft.) in length. It is desired to connect one remote user with a fiber
Consider a more typical use of Magnum 14Es in a shared Fast Ethernet segment. A
stack of Fast Ethernet hubs comprises the only repeater in the collision domain, and the users
and servers in the local workgroup are each connected via Category 5 twisted pair cable, a
NIC via fiber cable, using a Magnum 14Es in the circuit. How long can the fiber cable be?
minus 30 BT for one 30-meter TP cable from hub to user node leaves 292 BTs,
minus 5 BT for a short TP cable from the hub to 14E leaves 287 BTs,
minus 20 BT for one Magnum 14E leaves 267 BTs for fiber cable,
minus 90 BT for one Class II stackable repeater leaves 322 BTs,
512 = total available Bit Times in a collision domain diameter, minus 100 BT for two DTEs on each end leaves 412 BTs,
allowable maximum cable distance vs. TP cable without the 14Es.
which indicates a fiber cable length of about 260 meters.
The solution is :

straightforward. Using a properly terminated media segment, simply attach the cable end to the
Connecting Ethernet media to the Magnum 14E Media Converter is very simple and
segment to the RJ-45 port on the Magnum 14E Media Converters. The procedure is the same
LED is not illuminated, change the setting of the up-link switch (See Section 4.4 for
The following procedure describes how to connect a 100BASE-TX twisted pair
appropriate connector. See Sections 4.2 and 4.3 for a description of the LEDs.
3.5.1 Connecting Twisted Pair (RJ-45 standard)
for both unshielded and shielded twisted pair segments.
3.5 Connecting Fast Ethernet Media

be operable for LINK to be indicated. Absence of LINK does not point to the problem
The following procedure applies to 100BASE-FX applications using the Magnum 14E
up-link switch information.) If this does not help, ensure that the cable is connected
3.5.2 Connecting Fiber Optic 100BASE-FX, Type ST and SC, MM and Sgl.M
Media Converter with ST-type (twist-lock) and SC-type (snap-in) fiber connectors.
at regular intervals; you must use the color-coded strand on the associated
dampened in alcohol. Make certain the connectors are clean before connecting.
the connectors on the Magnum 14E. Save these dust caps for future use.
cable segment, and the fault may be in either.
ports at each end of the fiber optic segment.
properly at both ends and is not defective.

Receive (RX) port of the remote device. Begin with the color-coded strand of the cable
The following procedure applies to 100BASE-FX applications using the Magnum 14E
is ON in the units at each end). If LINK is not lit after cable connection, the normal
cause is improper cable polarity. Swap the fiber cables on the product connector to
3.5.3 Connecting Fiber Optic 100BASE-FX, Type MT-RJ Small Form Factor
Media Converter with MT-RJ (snap-in, two-fibers-in-one-piece) fiber connectors.
of the remote device. Use the non-color coded fiber strand for this.
for this first “Transmit-to-Receive” connection.
remedy this situation.

cause is improper cable seating. Re-insert the fiber cables on the product connector to
is ON in the units at each end). If LINK is not lit after cable connection, the normal
dampened in alcohol. Make certain the connector is clean before connecting.
that it only goes in one way, aligning the fiber pair for transmit and receive.
TX and RX fiber elements are correctly positioned.
of the connector on the Magnum 14E.
possibly remedy this situation.

This section describes the operation of the Magnum 14E Media Converters including
Magnum 14E Media Converters require 4 watts of power and are designed to be used
with an external power supply. The external power supply unit supplied is one of two types;
one version ("-d" models) for AC input power of 115 vac 60 Hz, and one version for 230 vac
50 Hz. The 115 vac version has a small transformer integral with a convenience power outlet plug. The 230 vac version ("-i" models) has a small transformer integral with an IEC-type
power plug for a user-supplied AC power cord with a convenience power outlet plug. Both
types include a lightweight DC power cord to the applicable power jack on the Media
power supply, up-link switch and AN/reg functionality, and LEDs.
4.1 Power Requirements, Power Supply Types
Converter unit.

LINK, Fiber port Steady ON when both attached cable segments are operational at
their respective other ends, blinking when receiving remote fault
PWR Illuminates GREEN to indicate the unit is receiving DC power.
LINK, Copper port Steady ON when the attached cable segments are
RX/ACT Activity, blinking indicates port is receiving
operational at their respective other ends
4.2 Dual LED Indicators (front and side-panel LEDs)
from the other end.
LED Description

accommodate switch- or repeater-to-converter connections without a special cross-over cable.
Media Converter is wired with cross-over functionality for direct up-link to a network hub or
When set to the straight position (=), the Magnum 14E Media Converter is wired for normal
twisted pair connection to a user node device. When set to the cross-over position (X), the
See Figure 4.4 below for the location of the switch on the Magnum 14E Media
Magnum 14E Media Converters are equipped with an up-link slide switch to
4.3 Up-Link or “Cross-over” Switch (On the RJ-45 port)
Converter unit.
switch.

Auto-Negotiation support to send Fast Link Pulses (FLP’s) to the attached device, or (b) reg
the increasingly popular auto-negotiate-only variety, it needs to get FLPs from the 14E Media
copper port. It is located just underneath the up-link switch, and is very tiny. See Figure 4.4
The AN / reg switch provides the flexibility to the user to manually select either (a)
switch or hub or NIC at the other end of the twisted pair cable. If the attached port is of
Magnum 14E Media Converters are equipped with a manual switch on the RJ-45
mode for regular or normal operation. In all cases, the unit functions at both FDX and HDX
The difference in the two settings is for the attached port, i.e., the port in the
4.4 Manual AN / reg Switch (Auto-negotiate or Full-duplex Fixed 100Mb)
transparently, but always at 100Mbps speed. The factory default setting is AN (Auto-
Negotiation).
below.

attached. In this case, the attached RJ-45 port (such as in a traditional managed switch) is set to
position causes FLPs to be sent, advertising full-duplex capability. BUT NOTE. . . it is up to
the user who chooses the AN position to determine that the device on the other end of the fiber
half-or full-duplex by the operator, and does not depend upon auto-negotiating FLPs. The 14E
Converter in order to decide what to do. Not receiving FLPs would indicate (incorrectly) that
cable is, in fact, capable of full-duplex operation. If it is not, choose the reg position and do
The reg position is also suitable for use when non-auto-negotiating devices are
itself is transparent half- or full-duplex, and will always operate correctly in this situation.
the Magnum 14E is only capable of half-duplex operation. Setting the switch in the AN
not advertise full-duplex.

Figure 4.4 End View of the 100Mb Magnum 14E Media Converter

attached copper cable along with the devices attached to both ends. When LINK is ON for the

copper cable, that status is passed to the fiber port’s LINK indicator of the 14E, and if the
14E’s allows network devices attached to the RJ-45 port to sense the LINK status of the
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
4.5 Standard LINK Pass-Through feature in 14E:
14E’s. It works one way only, i.e.,
RJ-45 LINK status pass-through to
fiber, in order not to interfere with
the auto-negotiation feature if it is
feature is standard in all Magnum

LINK problem elsewhere. If LINK Receive is invalid on the fiber side, LINK will be OFF on
through feature is indicating a LINK problem on another cable segment and you should check
Each LINK LED, then, may be OFF or ON or Blinking. If it is Blinking, the Pass-
through feature causes the LINK LED on the fiber port to blink rapidly to indicate there is a
If LINK is not present on the copper side but is valid for the fiber side, the Pass-
Fiber and ON for copper because the Pass-through does not apply to fiber-to-copper.
LINK is valid on the fiber segment, then LINK is ON for both ports of the 14E.
the cable connections and device power-on conditions accordingly.

Converters is a straightforward procedure (see INSTALLATION, Section 2.6); the operation
All Magnum Ethernet products are designed to provide reliability and consistently
Should problems develop during installation or operation, this section is intended to
help locate, identify and correct these types of problems. Please follow the suggestions listed
expected, do not attempt to repair the unit; instead contact your supplier for assistance or
high performance in all network environments. The installation of Magnum 14E Media
below prior to contacting your supplier. However, if you are unsure of the procedures
described in this section or if the Magnum 14E Media Converters is not performing as
is also straightforward and is discussed in Section 4.
contact GarrettCom Customer Support.

installation Section of the applicable chapter of this manual. Also check to make sure
Step 5 below. If the problem is corrected, the Magnum 14E Media Converters and its
Converter unit. Be certain that each AC power cord is plugged into a functioning
Converters product, it is recommended that the problem device is replaced with a
known good device. Verify whether or not the problem is corrected. If not, go to
installation. (About 90% of network downtime can be attributed to wiring and
and the cables/wires have not been crimped or in some way impaired during
electrical outlet. Use the PWR LEDs to verify each unit is receiving power.
that the various components of the network are interoperable.
associated cables are functioning properly.
5.1 Before Calling for Assistance
connector problems.)

Magnum 14E Media Converters unit or if unknown, contact GarrettCom, Inc.by fax,
including personal computers, workstations, terminals and printers; plus, the
d. Any particular application that, when used, appears to create the problem;
Include the date(s) that you purchased the products from your supplier.
to the occurrence of the problem. Any changes to system administration
phone or email (support@garrettcom.com) for assistance.
Please be prepared to provide the following information.
c. The components involved in the problem;
procedures should all be noted in this record.
a. The nature and duration of the problem;
various network media types being used.
b. Situations when the problem occurs;
5.2 When Calling for Assistance

438-9071 during business hours in California or email to support@garrettcom.com). When
All returns for repair must be accompanied by a Return Material Authorization
(RMA) number. To obtain an RMA number, call GarrettCom Customer Service at (510)
Failure symptoms, including a full description of the problem.
calling, please have the following information readily available:
5.3 Return Material Authorization (RMA) Procedure
Name and phone number of your contact person.
Packing List Number (or Sales Order Number)
Name of your company / institution
Serial Number (or Invoice Number)
Your shipping address · Date of installation · Product name

sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete
details). However, if the problem or condition causing the return cannot be duplicated by
GarrettCom will carefully test and evaluate all returned products, will repair products
under warranty. Testing and repair of product that is not under warranty will result in a
that are under warranty at no charge, and will return the warranty-repaired units to the
GarrettCom reserves the right to charge for the testing of non-defective units
No Problem Found.
GarrettCom, the unit will be returned as:
customer (user) charge.

Should you need to ship the unit back to GarrettCom, please follow these instructions:
shipping protection. ( You may retain all connectors and this Installation Guide.)
This material may cause electro-static shock damage to the unit.
5.4 Shipping and Packaging Information
Attn.: Customer Service
213 Hammond Ave. Fremont, CA 94539

workmanship for a period of three (3) years from the date of shipment by GarrettCom.
components in the products that prove to be defective at no charge other than shipping
This warranty will not be effective if, in the opinion of GarrettCom, the product
GarrettCom reserves the right to make a charge for handling and inspecting any
Please complete the warranty card as this acts as a product registration, and mail
GarrettCom, Inc. warrants its products to be free from defects in materials and
has been damaged by misuse, misapplication, or as a result of service or modification
During this warranty period, GarrettCom will repair or, at its option, replace
and handling, provided that the product is returned pre-paid to GarrettCom.
product returned for warranty repair which turns out not to be faulty.
it to GarrettCom within two weeks of your purchase.
other than by GarrettCom.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.