Magnum Quad-Series
Fiber Switches


serviceable parts. Attempted service by unauthorized personnel shall render all
Series Fiber Switch products, consult Section 6, Troubleshooting, of this User
GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a
warranties null and void. If problems are experienced with Magnum Quad
of this publication may be reproduced without prior written permission from
Copyright © 2003 GarrettCom, Inc. All rights reserved. No part
UL is a registered trademark of Underwriters Laboratories
NEBS is a trademark of Telcordia Technologies
Ethernet is a trademark of Xerox Corporation
registered trademark of GarrettCom, Inc.
Printed in the United States of America.
GarrettCom, Inc.
Guide.
Trademarks

This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to take whatever
Please use the mailing address, phone and fax numbers and email address listed below:
Radio Frequency Interference Statement
email support@garrettcom.com
47823 Westinghouse Dr. Fremont, CA 94539
GarrettCom, Inc.
measures may be required to correct the interference.
Federal Communications Commission · Fax (510) 438-9072 · Contacting GarrettCom, Inc


5.2.5 QPM-MV45, 100Mbps multi-mode FX Quad-Port VF45 small-38
5.0 INTRODUCTION - MAGNUM QUAD-SERIES (QPM)............... 35
5.1 Inspecting the Package and Product 35
5.2 Product Description 35
5.2.1 QPM-MST, 100Mb multi-mode FX-ST Quad-port Mod 36
5.2.2 QPM-MSC 100Mbps multi-mode FX-SC Quad-port, “snap-in”37
5.2.3 QPM-SSC 100Mbps single-mode FX-SC-type, “snap-in” con . 37
5.2.4 QPM-MTRJ, 100Mb multi-mode FX Quad-Port, MTRJ small- 38
5.2.6 QPM-RJ45 (Twisted Pair), 10/100Mb TP Quad-Port 39
5.2.7 QPRJ-MSC, “3 + 1” 3@10/100Mb RJ-45 and 1@100Mb Fib.. 40
5.2.8 QPRJ-MST, “3 + 1” 3@10/100Mb RJ-45 and 1@100Mb Fib.. 41
5.2.9 QPRJ-SSC, “3 + 1” 3@10/100Mb RJ-45 and 1@100Mb Fib... 41
6.0 TROUBLESHOOTING ...................................................................... 42
6.1 Before Calling for Assistance 42
6.2 When Calling for Assistance 43
6.3 Return Material Authorization (RMA) Procedure 43
6.4 Shipping and Packaging Information 44
APPENDIX C: MAGNUM INTERNAL DC DUAL-SOURCE POWER .. 47
125VDC Power Supply option Rev B 04/01 : Change the company name to GarrettCom, Inc. (Formerly it was
Garrett Communications). There are no changes to the content of the material at
Switch user manual.
Revisions · this time

GarrettCom, Inc.offers the premium-quality Magnum™ line of Ethernet LAN
connectivity products with industry-standard functionality and built-in fiber
configurability. Magnum products are designed for use in demanding Carrier Class,
Industrial Grade and OEM applications where reliability is a primary consideration.
6K25 Managed Fiber Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports, mix-and match. Features SFF fiber for up to 25 fiber ports in a 1U unit.
P62-Series “Outdoor Ethernet Switches, for temperature uncontrolled applications
6 10/100 and 2 100Mb fiber ports, managed and unmanaged models, all fiber types.
4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto-negotiating full switching performance.
Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed
8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series, regular and Hardened with integral
DC power, all fiber media port types incl. fiber ST, SC, mm., single-mode, SFF
Stackable Concentrators, SNMP optional, 13-Ports
Transceivers, 10Mb series Mini-Transceivers and Coax Models June, 03
Mixed-Media Fiber Hub, 16-port Stackable,10/100 auto-sensing
Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing
10Mb series and 100Mb series, both w/ optional port modules Personal Switches, 10/100Mb
Bridge Port Modules (BPMs), 4 types, for segment isolation
Repeater Port Modules (RPMs), 6 types for Ethernet media
The “X-line” of configurable MiXed Media products:
and mixed-media types, full switching performance.
8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb
Mini-Concentrators, 7 Ports, Repeaters, 2-Ports
Stackable Hubs, SNMP Optional
8-port, with two switched ports (1 fiber built in)
Personal Hubs, 10Mb series

(all ports are wire speed) 1,190,400 frames/sec for 8 100Mbps ports (for Magnum QS580 & QS5108)
(all ports are wire speed) 1,190,400 frames per second, 16-port units 595,200 frames per second, 8-port units Data Rate: 10 Mbps and 100Mbps Address Table Capacity: 24K node addresses, self-learning (12K on 8-port models), with address aging Packet buffer size : 8 MB dynamic (4MB for 8-port) Latency: 5 µs + packet time (100 to 100Mbps) 15 µs + packet time (10 to 10 Mbps, and 10 to 100Mbps) Network Standards
(for Magnum Quad-Series Fast Ethernet copper ports, use Cat 5 cable)
10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)
100BASE-FX, full-duplex, single-mode - 15.0 km (49,215 ft)
Unshielded twisted pair - 100 m (328 ft)
10BASE-FL single-mode fiber optic - 10 km (32,810 ft)
10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)
100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft)
100BASE-SX, short wavelength HDX m.m. - 300 m ( 935 ft) 100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)
Shielded twisted pair - 150 m (492 ft)
100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft)
Shielded twisted pair - 150 m (492 ft)
Maximum Standard Fast Ethernet Segment Lengths:
Maximum 10 Mbps Ethernet Segment Lengths
Fiber Multi-mode connector types:
Connectors for copper wiring
1.0 SPECIFICATIONS
Performance

Dimensions: 1.75 in H x 17.0 in W x 9.13 in D (10.0 in W for QS580)
4.45cm H x 43.2cm W x 23.2cm D (25.4 cm W for QS580)
Weight: 4.0 lb. (1.8 Kg) for rack-mount models, 2.5 lb. for table-top Cooling method: Fan cooled, @ 9 cfm
For optional 23” Telco rack-mount brackets, order Model # RMB-23W
Warranty Three years, return to factory Made in USA
For Dual Source and Redundant DC for –48VDC, 24VDC Power &
with adjacent manual ON-OFF switch (on AC models only)
select fixed 100Mb full-duplex, or fixed 100Mbps half-duplex)
35 watts typical (16 port model)
125VDC supply options (Optional), see Appendices
Storage Temperature: -40°to 185°F (-40°to 85°C)
Redundant power supplies available as options
OFF = Half-Duplex Mode
Emissions meet FCC Part 15 Class A
Manual switch-selections and jumpers
Fiber Single-mode connector types:
UL listed (UL1950), cUL, CE
Agency Approvals

and 8MB packet buffers. Holds up to 4 Quad-port Modules
(QPMs), 19” rack-mount package, with mounting brackets.
QPRJ-MSC 3TP+1F “3+1 combo” module for Quad-Series Switches, with three 10/100MB auto-negotiating RJ-45 ports and one
QPM10-FST Fiber module for Quad-Series Switches, with four 10 Mbps
Magnum QS580 8-port 10/100 Switch, holds up to 2 Quad-port Modules with 4 switched ports each. Shelf or table-top mounting.
various fiber port connector types, modes, and speeds can
Magnum QS5116 Same as Model QS5108, but with 24K-node address table
100Mbps auto-negotiating RJ-45 ports, one of which has an up-link push-button
For mixed-media flexibility, combinations of RJ-45 and
100Mbps speed across all ports, self-learning 12K-node address table, and large 4MB packet buffers. Front-
Magnum QS5108 Same as Model QS580 Switch, but in a 19” rack-mount
QPRJ-MST 3TP+1F “3+1 combo” module, same as QPRJ-MSC but with fiber ST-type connector
QPRJ-SSC 3TP+1F “3+1 combo” module, same as QPRJ-MSC but with fiber single-mode FX SC connector
fiber port with 100Mbps multi-mode FX SC connector
be configured. Full speed filtering and forwarding at
mounted LEDs, internal auto-ranging power supply
100Mbps multi-mode FX “MTRJ” connectors QPM-RJ45 RJ-45 module for Quad-Series Switches, with four
QPM-MSC Fiber module for Quad-Series Switches, with four
100Mbps multi-mode FX SC connectors QPM-MST Fiber module for Quad-Series Switches, with four
100Mbps multi-mode FX ST connectors QPM-SSC Fiber module for Quad-Series Switches, with four
100Mbps single-mode FX SC connectors QPM-MV45 Fiber module for Quad-Series Switches, with four
100Mbps multi-mode FX “VF-45” connectors QPM-MTRJ Fiber module for Quad-Series Switches, with four
GarrettCom, Incl. reserves the right to change specifications, performance
multi-mode FL ST-type connectors
package, with mounting brackets.
characteristics and/or model offerings without notice.
Magnum Quad-Series Port Modules
1.2 Ordering Information

product; notify the carrier of any damage that you believe occurred during shipment or
Remove the items from the shipping container. Be sure to keep the shipping
In the event there are items missing or damaged, contact the party from whom
delivery. Inspect the contents of this package for any signs of damage and ensure that
shipping container if possible. Refer to Section 6, Troubleshooting, for specific return
Examine the shipping container for obvious damage prior to installing this
container should you need to re-ship the unit at a later date. To validate the product
you purchased the product. If the unit needs to be returned, please use the original
1 Set of metal “Ears” for optional “19” rack mounting (for QS5108 &
warranty, please complete and return the enclosed Product Registration Card to
1 Set of two wall-mounting brackets (for QS580 Model only)
1 Magnum QS580, QS5108 or QS5116 Fiber Switches
1 AC Power Cord (U.S. and other 115 VAC only)
1 Installation and User Guide (this manual)
1 Product Registration Card
This package should contain:
GarrettCom, Inc. as soon as possible.
the items listed below are included.
procedures.
QS5116 only)

offers the flexibility of four, eight, twelve or sixteen switched 100Mbps or 10 Mbps fiber
Series offers the QS580, QS5108 and QS5116 models, each with a configuration of four
combo (3@RJ-45 and 1@fiber) port modules. The Quad-port Modules can be configured
and in network traffic centers, the Magnum Quad-Series Switches are easy to install and
use. Addresses of attached nodes are automatically learned and maintained, adapting the
Magnum Quad-Series Switches come in three chassis sizes, an 8-port table-top,
an 8-port rack-mount, and a 16-port rack-mount. Each is configurable with a selection of
Magnum Quad-Series Fiber Switches boost the performance of large Ethernet
types of fiber port connectors and modes, as well as allowing a mix of 10/100Mb RJ-45
the unit to the individual application’s changing mixed-media requirements for a 10/100
smoothly support multiple workgroups at 100Mbps or 10 Mbps speed. The Quad-Series
and/or 10/100 twisted pair ports, in all the popular connector types. The Magnum Quad-
Designed for use in departments with multiple workgroups, in remote offices
performance plug-and-play operation in convenient table-top and rack-mount packages.
(copper) ports in the same unit. This flexibility is achieved via a family of quad-port
modules that can be integrated with a base unit, in the factory and in the field, to adapt
The Magnum Quad-Series provide the switching speed and the reliability to
switching services to network changes and expansions. Front-mounted LEDs provide
quad-port (i.e., 4-port) modules, providing the capability of 4, 8, 12, and 16 switched
The 8-port QS580 table-top chassis is compact in size and suitable for shelf-
“mixed-media” capability provides for a variety of configurations including various
ports. The quad-port modules are normally factory installed, but may be changed or
LANs, and have the flexibility of both fiber and twisted-pair switched ports. Their
port modules (Quad-port Modules) for fiber types and for copper, as well as “3+1”
status information on each port. The Magnum Quad-Series Switches provide high
into a Quad-Series Switch base unit in any mix of port connector or media types.
mounted use in network wiring centers. The QS5108 and QS5116 are 19” rack-
added in the field. (See Section 5)
Switch product.

. Mixed-media combination modules (4-port modules with three fiber ports and
the IEC standard AC power connector (and a manual ON - OFF power switch) located at
mountable Switches with two or four quad-port slots in the front, i.e., with a capacity of
8 or 16 switched ports. The QS5108 and QS5116 rack-mount units are typically used in
one twisted-pair port) are supported in all of the Quad-Series Fiber Switch models. All
quad-module manual-selection switches and LED’s are located on the front panel, with
port Magnum QS580 table-
top, 8-port QS5108 and 16-

47-63Hz 1.0-0.5A

OFF
110-220 VAC

the rear. Fan-driven cooling air flows left to right.
larger network wiring centers.
ON
OFF
110-220 VAC
47-63Hz 1.0-0.5A

Fig.2.2.2 Fiber Quad-Port Modules, QPM ST, QPM-SC, QPM-MTRJ, QPM-MV45
same multi- or single-mode, and the same connector type. Multi-mode 100Mbps models
are available with ST, SC, MTRJ, and VF-45 connectors. Single-mode 100Mbps models
The 100Mb fiber quad-port modules on the Magnum Q-Series normally are set
On the Magnum Q-Series, the user may select full- or half-duplex mode per-port with an
On Magnum fiber QPMs, there are three LED’s per fiber port. The Link (LK)
duplex mode when ON (when it is OFF, operation is half-duplex), and an LED indicates
port and a proper link (LK lit) must be made with the device at the other end of the cable
(factory default) to operate in full-duplex mode for best fiber distance and performance.
Receiving Activity (ACT) on the port. A fiber cable must be connected to each 100Mb
100Mb QPM-MST, except for 10 Mb speed
In a fiber quad-port module, all of the fiber ports are of the same speed, the
internal jumper setting (See Section 3.4) for the flexibility to adapt to any type of Fast
LED indicates “ready for operation” when lit, another LED indicates operation in full-
ACT
ACT LK
1 2 3 4
1 2 3 4
1 2 3 4 2.2.3 Quad-port modules, 10 Mb
in order for the LK LEDs to provide valid indications of operating conditions.
LK
LK FDX/HDX
FDX/HDX
2.2.2 Quad-port modules, 100Mb fiber
The 10 Mb model QPM10-MST
fiber quad-port module is the same as the
LK FDX/HDX ACT
1 2 3 4
1 2 3 4
are available with SC connectors.
SC-Type
Ethernet devices.
FDX/HDX

rather than 100Mb speed. It supports distances according to the 10Base-FL standard, i.e.,
2Km distance for multi-mode fiber. (Single-mode for 10km distance may be available as
They independently move to half-duplex mode at 10 Mb or at 100Mb speed if the device
On the model QPM-RJ45 , there are four LED’s for each port. The LK (Link)
indicates “ready for operation” when lit. The ACT (Activity) indicates receiving activity
on that port when lit. The 10/100 LED indicates operation at 100Mb speed when ON and
at 10 Mb speed when OFF (when auto-negotiation is not disabled). The FDX/HDX LED
is ON to indicate full-duplex operation and OFF to indicate half-duplex mode. A twisted
auto-negotiation feature and to manually set each port at full-duplex or half-duplex. One
pair cable must be connected into each RJ-45 10/100Mb port and a proper Link (LK lit)
for operation at 10 or 100Mb speed in full- or half-duplex mode (as a default setting).
Internal jumper settings (See Section 3.4) allow technicians to over-ride the
100/10 FDX/HDX
at the other end of the twisted pair cable is half-duplex or is not an auto-negotiating
port on each RJ-45 quad-port module is equipped with a Media Dependent Interface-
Crossover (MDI-X) push-button switch to simplify cascaded or up-link connections.
must be made with the device at the other end of the cable in order for the LEDs to
FDX/HDX
2.2.5 Combo “3 + 1” Quad Port Modules, 3@RJ-45 and 1@fiber
way auto-negotiating. QPM-RJ45
1 2 3 4
mode fiber ST or SC or single mode SC-type port. QPRJ-MSC
2.2.4 Quad-Port Module, RJ-45 (copper)
LK
provide valid indications of operating conditions.
The combo quad-port modules are
copper ports and one 100Mb switched multi-
available as three 10/100 switched RJ-45
combination of copper and fiber media,
switched. RJ-45 ports. The 10/100Mb
switched ports are independently N-
copper port module, model QPM-
RJ45, provides four 10/100Mb
a special order).
device.
100/10 · The Magnum Q-Series

evenly across all ports, resulting in a small, fixed number of packets to be stored per port.
While other switching technologies such as "cut-through" or "express" impose
minimal frame latency, they will also permit bad frames to propagate out to the Ethernet
there is no way to filter frames with a bad CRC (the entire frame must be present in order
traffic congestion, especially at peak activity. Since collisions and bad packets are more
selected. The default condition is full-duplex. Internal jumper settings allow technicians
On Magnum Combo Quad-port modules, there are four LED’s for each RJ-45
packet) is loaded into the Switch’s memory and inspected before forwarding can occur.
which are a result of late collisions, to be forwarded to add to the network traffic. Since
for CRC to be calculated), the result of indiscriminate cut-through forwarding is greater
When the port buffer fills up, dropped packets result.) The other two Q-Series Switches
The RJ-45 ports run at 10/100Mbps with N-way auto-negotiation capability,
port, which indicate status as described for the QPM-RJ45 in Section 2.2.4 above. The
fiber port is fixed at 100Mbps speed at all times, and has LEDs that indicate status the
segments connected. The "cut-through" technique permits collision fragment frames,
Magnum Quad-Series QS5116 Switches dynamically allocates buffer space from an 8
MB memory pool, ensuring that heavily used ports receive very large buffer space for
whereas the fiber port runs at 100Mbps with half- or full-duplex capability manually
The Magnum Quad-Series are store-and-forward switches. Each frame (or
correct CRC, i.e., are good packets. This eliminates the propagation of bad packets,
packet storage. (Many other switches have their packet buffer storage space divided
dynamic buffer allocation provides the capability for the maximum resources of the
This technique ensures that all forwarded frames are of a valid length and have the
likely when traffic is heavy, the result of store-and-forward operation is that more
To minimize the possibility of dropping frames on congested ports, each
QS580 and QS5116 dynamically allocates buffer from an 4MB memory pool. This
same way as described for the Fiber Quad-port modules in Section 2.2.2 above.
enabling all of the available bandwidth to be used for valid information.
bandwidth is available for good packets when the traffic load is greatest.
to set the 100Mb fiber port to half-duplex mode. (See Section 3.4).

Magnum Quad-Series unit to be applied to all traffic loads, even when the traffic activity
sending traffic, which allows a traffic catch-up to occur without dropping packets. Then,
normal packet buffering and processing resumes. This flow-control sequence occurs in a
switches. For 10 Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the
Switches are constantly adapting internally to provide maximum network performance
Another feature implemented in Magnum Quad-Series Switches is a collision-
based flow-control mechanism (when operating at half-duplex only). When the Switch
The latency (the time the frame spends in the Switch before it is sent along or
is unbalanced across the ports. Since the traffic on an operating network is constantly
varying in packet density per port and in aggregate density, the Magnum Quad-Series
sends industry standard (full-duplex only) PAUSE packets out to the devices sending
entering by forcing a collision signal on all receiving half-duplex ports in order to stop
types, and the length of the frame is a variable here as it is with all store-and-forward
When the Switch detects that its free buffer queue space is low, the Switch
detects that its free buffer queue space is low, the Switch prevents more frames from
forwarded to its destination) of the Quad-Series Switches varies with the port-speed
packets to cause “flow control”. This tells the sending devices to temporarily stop
latency is 15 microseconds plus the packet time at 10 Mb. For 100Mb-to-100Mb
small fraction of a second and is transparent to an observer. See Section 4.6 for
forwarding, the latency is 5 microseconds plus the packet time at 100Mb.
with the least dropped packets.
additional details.
incoming traffic.

100Mb switching services for large, high performance Ethernet LANs
Quad-port modules are available with 100Mb mm ST, SC, VF-45, MTRJ
single-mode SC, and 10 Mb ST-type connectors. The configuration of the
RJ-45 Quad-port modules provide twisted pair segment connections, with
adapting the Quad-Series Switches to varying quantities and types of fiber
individually selected. All RJ-45 ports support 10/100 auto-negotiation, or
Magnum Quad-Series Switches are self-learning for node addresses. They
fiber ports, in the factory or in the field, allows the Quad-Series Switches
N-way auto-negotiation or with manual speed and mode settings per port
can be placed into operation without complex set-up procedures, even in
Front panel LED’s on each quad-port module display the status of each
Magnum Quad-Series Switches provide Fast Ethernet switching on all
ports. They perform high speed filter/forward operations on the traffic,
Combinations of port module types can be configured in the same unit,
QPMs, capacity options complement the mixed-media configurability.
Configurable with RJ-45 (copper) ports, 10/100 auto-negotiation
vs. copper media. Port module changes can even be done in the field.
All fiber and RJ-45 (copper) ports are capable of half- or full-duplex,
port for easy monitoring. An internal auto-ranging AC power supply
allows any Magnum Quad-Series Switches to be used throughout the
giving each port’s segment a full 100Mb (or 10 Mb) of bandwidth.
With two chassis sizes (16-port and 8-port) configurable with 4-port
Configurable with fiber ports, all connector types and speeds
to adapt to mixed and changing fiber types in any application.
can be user-selected for the desired operating mode and speed.
Plug-and-Play installation for high performance switching
world. (A 48VDC power supply is optional, see Appendix B).\
large networks. They operate transparent to system software.
Mixed-media configurations for maximum flexibility
Front-mounted LEDs, world-wide AC power supply
Full-duplex or Half-duplex operation, auto-sensing
16-port, 12-port, 8-port and 4-port models

applications. The Dual-Speed characteristic of the Quad-Series Switches enables them to
Mbps hubs connect a group of users who share one 10 Mb traffic domain. The Magnum
case, two 100Mb fiber connections are required to connect to more distant LAN centers,
The Magnum QS580 provides complete network connectivity so that all 10 Mb
center. The subnet connections may be via either fiber or twisted pair cabling, and may
In a typical 10 Mb network performance upgrade, some existing cascaded 10
existing network into multiple domains, providing greatly increased bandwidth. In this
switched network facility. It filters and forwards packets from one segment to another,
containing the local traffic and allowing only the packets which need to be forwarded to
computing, performance upgrades of departmental networks, and collapsed backbone
Magnum Quad-Series Mixed-Media Switches offer high performance and
The mixed-media capability is ideal for upgrading existing Ethernet LAN
networks, where existing cabling must be accommodated. The fiber-built-in media
go outside to the appropriate other segments. This is ideal for a central departmental
inter-connect a series of subnets (one subnet per Q-Series Switch) in a LAN traffic
capability is ideal for integrating future-proof fiber cabling into the LAN structure.
QS580 Quad-Series Switch provides eight 10/100Mb traffic domains for increased
performance. It can segment 10 Mbps and 100Mbps units, hubs and servers, in the
and a configuration with two “combo” 3@RJ-45 + 1@fiber-built-in QPMs is used.
RX PWR COL 1 2 3 4 5 6 7 8
flexibility, and are easily used in a variety of applications including client/server
and 100Mb nodes operate in a unified manner, functioning as one plug-and-play
switch in a high-performance LAN center. Figure 2.4 illustrates this example.
Workgroup Hub 100 Mb/s GARRETT
GARRETT FDX/HDX
be 100Mbps or 10 Mbps speed and full-or half-duplex mode.
ACT LK
RX PWR COL 1 2 3 4 5 6 7 8
100Mbps bandwidth on each segment. 10 Mbps users
full 10 Mbps and

In another application, a Switch is needed to provide a Fast Ethernet backbone.
full-duplex fiber lines. In addition to interconnecting the fiber backbone segments in the
network center, the Switch needs to provide high-speed switched support for two central
needed. The Fiber QPM can be selected to provide any 100Mbps fiber media connector
provides a switched port for two local high speed servers, another for the router, another
Since 100Mb fiber Ethernet has severe distance limitations at half-duplex, it is
negotiation and would not enable the fiber backbone lines to operate full-duplex. But the
Magnum QS5108 . . . with built-in switched fiber ports at 100Mb speed, with full-duplex
100Mbps fiber and four 10/100 RJ-45) in a rack-mount box. No Media Converters are
necessary in high speed backbones to operate fiber links in the full-duplex mode. Many
mode as a default setting on fiber ports, and with some RJ-45 N-way 10/100Mb ports as
The backbone consists of four high-speed LAN segments, each operating over 100MB
servers, for a 100MB connection to a router, and for a dual-speed hub serving a local
for the users connecting into a 16-port dual-speed hub such as the Magnum DS8016.
This requirement for connecting local devices over twisted pair cabling is
handled by the Magnum QS5108 using a 4-port RJ-45 Quad-Port Module. The QPM
low-end switches that only have RJ-45 N-way 10/100Mb ports would need to have a
The Magnum QS5108 equipped with one Fiber and one RJ-45 quad-port
media converter on each fiber line. But most media converters do not support auto-
Figure 2.4b: The Magnum QS5108 provides a 100Mb fiber backbone facility.
modules provides an economical solution, configured with 8 switched ports (four
type desired. QPMs with multi-mode or single-mode fiber types are available.
100/10 FDX/HDX
workgroup of over a dozen users, printers, etc.
LK ACT Fiber Switch Magnum QS5108
well. . . handles this application readily.
PWR
TT GARRE
1 2 3 4 5 6 7 8 9 10 11
RX PWR COL
1 2 3 4 5 6 7 8
12 13 14 15 16 X
Magnum DS8016 Stackable Hub
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
LK/RX
PORT
PWR BR
COL 10
COL 100

more fiber backbone segments, then two quad-port fiber QPMs are selected to provide 6
100MB Media Converter (such as the Magnum 15E) may be used on a copper port, with
copper support for 4 high speed local servers. In addition, the router and two dual-speed
The mixed-media flexibility of the Magnum Quad-Port Switches provides the
user with more than one configuration in this case. The two ports not immediately used
the Magnum QS5116. Should the number of servers expand, more than one server can
If the probable growth of the central Switch is towards more local high speed
servers and users, then one quad-port fiber QPM is selected to provide 4 of the required
fiber ports, and two “combo 3@RJ-45 + 1@fiber” QPMs are configured for the other 2
fiber ports plus 6 of the switched copper ports. Finally, an RJ-45 QPM is configured to
Should the need arise to add a built-in-fiber backbone port in the future, the RJ-45 QPM
could be removed and another “3+1 combo” QPM installed in the field. Alternatively, a
needed to provide for a 6-segment 100Mb fiber Fast Ethernet backbone, and switched
may be either fiber or copper. If the probable growth of the central Switch is towards
switched copper ports are handled with two RJ-45 Quad-Port Modules configured into
provide for the remaining 2 copper ports plus two for spares and/or future expansion.
internal jumpers (See Section 3.4) set to support fixed 100MB FDX on the RJ-45 port.
In another situation similar to Example 2 above, a larger central Switch is
Fig 2.4c: Magnum QS5116 provides a 100Mb mixed-media backbone Switch.
required fiber ports and two for spares and/or future backbone expansion. The 8
be serviced by a switched QS5116 port by using a small 4-port 100Mbps hub.
hubs need switched copper ports. The total is 14 ports, 6 fiber and 8 copper.
1 2 3 4 5 6 7 8 9 10 11
Magnum DS8016 Stackable Hub
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ACT LK
100/10 FDX/HDX
LK/RX
PORT
PWR BR
COL 10
COL 100
RX LINK
RX PWR COL
1 2 3 4 5 6 7 8
LINK
ACT LK
1 2 3 4 5 6 7 8 9 10 11
12 13 14 15 16 X
FDX/HDX 4
Magnum DS8016 Stackable Hub
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ACT
LK/RX
PORT
PWR BR
COL 10
COL 100
LK
FDX/HDX 4
GARRETT

1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment
2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate air flow must be maintained for proper and
3.) If the equipment is mounted in an enclosed or multiple rack system placement of the equipment must not overload or load
4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent
5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and
layout of the network. Typically the Switch is placed in a central wiring location where
top. The compact size of the 8-port QS580 unit allows it to be easily placed in an office
the unit so that cooling can occur from the small fan on the left side, while the unit is in
The location of a Magnum Quad-Series Switch is dependent on the physical
other. These Switches are typically rack mounted in a wiring closet see Section 3.3.2
below), but because they have rubber feet they can also be installed on a shelf or table
or lab area, and it can also be either shelf of wall-mounted (see Section 3.3.1 below).
normally protect it from accidental damage in a lab or workplace setting. Maintain an
open view of the front to visually monitor the status LEDs. Keep an open area around
Before installing the equipment, it is necessary to take the
groups of network devices need to be connected in order to communicate with each
Magnum Quad-Series site. The rugged metal case of the Magnum Quad-Series will
Locate an AC receptacle that is within six feet (2 meters) of the intended
47-63Hz 1.0-0.5A FAN EXHAUST
overloading of the building/s electrical circuits.
as well as connection of the various Ethernet media types.
must be less than or equal to 500C.
OFF
110-220 VAC
uncompromised earthing path.
unevenly the rack system.
following precautions:
operation. See figure below.
safe operation.

is accomplished by using a family of Quad-port Modules (QPMs) which can be
individually selected and configured per-port. See Section 2.4 for a description
small form factor mm1 Fiber 2.0km (6,562 ft) QPM-MTRJ, -MV45 10BASE-FL mm1 Fiber 2.0km(6,562 ft) QPM10-FST
connection has been established at both ends (and when power is ON in the unit).
The Magnum Quad-Series Fiber Switches are specifically designed
to support all standard Ethernet media types within a single Switch unit. This
The following procedure applies to installations using a QPM with ST-type fiber
connectors. This procedure applies to ports using a QPM-MST or QPM10-MST.
dampened in alcohol. Make certain the connectors are clean before connecting.
(TX) port of the remote device. Use the non-color coded fiber strand for this.
Receive (RX) port of the remote device. Begin with the color-coded strand of
polarity. Swap the fiber cables at the QPM connector to remedy this situation.
The various media types supported along with the corresponding IEEE
If LINK is not lit after cable connection, the normal cause is improper cable
bands at regular intervals; you must use the color-coded strand on the
100BASE-FX mm1 Fiber 2.0km (6,562 ft) QPM-MSC, -MST sgl.m2 Fiber 18.0km (95K ft) QPM-SSC
IEEE Standard Media Type Max. Distance Port Module
1 mm = multi-mode 2 sgl.m = single-mode
10BASE-T & 100BASE-TX twisted pair 100m (328 ft) QPM-RJ45
802.3 and 802.3u standards and connector types are as follows:
3.2.1 Connecting Fiber Optic ST-type, “twist-lock”
associated ports at each end of the fiber optic segment.
the cable for this first TX-to-RX connection.
of the QPMs.
Fiber:

When connecting fiber media to SC connectors, simply snap on the two square
(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx
fiber allows full bandwidth at longer distances, and may be used to connect 10 Mb nodes
The RJ-45 ports of the Magnum Quad-Series can be connected to the following
making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3
may be used. In either case, the maximum distance for unshielded twisted pair cabling is
mixed-speed network, since dual-speed ports are auto-sensing for either 10 and
connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable
are the diameters of the core and the core plus the cladding respectively). Single-mode
The following procedure describes how to connect a 10BASE-T or 100BASE-
The following procedure applies to installations using a QPM with SC-type
Twisted Pair (CAT 3, 4, 5) 10BASE-T RJ-45
TX twisted pair segment to the RJ-45 port. The procedure is the same for both
fiber connectors, i.e., using QPM-MSC, QPM-SSC single-mode, and QPM10-MSC.
When using single-mode fiber cable, be sure to use single-mode fiber port
The same procedures as for multi-mode fiber applies to single-mode fiber
and 100Mb) be used whenever possible in order to provide flexibility in a
Twisted Pair (CAT 5) 100BASE-TX RJ-45
male connectors into the SC female jacks of the QPM until it clicks and secures.
Media IEEE Standard Connector
shielded, either unshielded or shielded cables and wiring may be used.
3.2.2 Connecting Fiber Optic SC-type, "Snap-In"
connectors. Follow the steps listed in Section 3.2.2 above.
unshielded and shielded twisted pair cables.
up to 10 Km apart, or 18Km with the QPM-SSC.
100 meters (328 ft).
100Mb/s.
Shielded)

(and screws) to allow the unit to be mounted in nearly any desired orientation or position.
The brackets are attached to the metal switch case using one of the metal screws for each
user-supplied screw attaches the bracket to the mounting surface. It is recommended that
attached, the brackets will extend slightly below the base of the unit to allow clearance
Installation of a Magnum QS5108 and QS5116 mixed-media fiber Switch in a
The Magnum Quad-Series Switches can be easily mounted on a table-top or
Each Magnum QS580 Switch is shipped with two metal mounting brackets
bracket, and attached to the Magnum QS580 through the round hole of the bracket. A
the mounting brackets be attached to two opposite corners of the unit. When properly
any suitable horizontal surface, and has four rubber feet to provide stability without

view and easy to read. Rack-mount installation requires special 19” rack-mounted
FDX/HDX
ACT LK ACT ACT
3.3.1 Wall (or Vertical Surface) Mounting, 8-port QS580
mounting 0, optional brackets Proper mounting
FDX/HDX 4
3.3.2 Rack-mounting, models QS5108 and QS5116
LK ACT 100/10
for the rubber feet and for cooling fan exhaust space.
3.3 Table-Top or Shelf Mounting
PWR
TT
GARRE

19” rack is a simple procedure.
The units are 1U (1.70”) high.
scratching finished surfaces.
When properly installed, the
indicators should be in plain


to the front sides of the switch, which is then fastened into a standard 19” RETMA rack.
brackets and screws (included with each QS5108 and QS5116 unit). The brackets attach
brackets are more popular in Telco industry where they are standard for Central Office
The 23” brackets and ETSI brackets are also available (optional) for Rack-
mounting of Magnum QS5108 and QS5116 mixed-media fiber Switches. The 23”
Fig 3.8 Multiple Magnum QS5116 units rack-mounted in a 23” frame
23” brackets are mainly used for
frequently accessed in operation
Telephone standard) brackets are
the ETSI brackets come as a pair
larger equipment assemblies in
rack-mounting frames, and are
similar to the 19” brackets but
The optional 23” brackets and
necessary screws for attaching
rack-mounting purposes. The
in a package, along with the
the brackets to the sides of
the Magnum Switch unit.
use metric dimensions.
from both sides.
The ETSI (European

power is disconnected before opening the unit or changing any internal jumper settings.
negotiation. This is desirable when there are unknown devices presently or potentially
duplex and does not support Auto-negotiation; or the connected device does not support
Auto-negotiation properly) no auto-negotiation is better and the internal jumper settings
your setup, internal jumpers allow the speed and mode of the Q-Series RJ-45 (copper)
connected, which will not operate correctly with auto-negotiation. Examples include
Therefore, the default setting of auto-negotiation (copper ports) is generally
without re-configuration. Under certain conditions,(where the connected device is full
3.4 RJ-45 ports, internal jumper settings for 10/100Mb (auto- negotiation) or for fixed Half- or Full-Duplex @ 100Mb, per port

Figure 3.4. RJ-45 ports, internal jumper settings. Note: Be certain that the main
depended upon to work as expected. If auto-negotiation will not function properly in
desirable because it is widely used and allows for the connection of various devices
The factory (or default) setting is for auto-negotiation on all RJ-45 ports, which is
generally popular. It works well under most circumstances, but cannot always be
Two(50) Pin QPM Connectors (inserts into main board)
quad-ports to be fixed, even if the attached device may or may not support auto-
Jumper Settings for Auto-Negotiation, or for 100MB Half or Full Duplex
will permit this to be selected on a per-port basis.
some NICs and most Media Converters.

3.5 Fiber 100Mb ports, internal jumper settings for 100Mb fixed Half- or Full-Duplex, per port
quad-ports to be fixed, even if the attached device may or may not support full-duplex.
Therefore, the default setting of full-duplex (fiber ports) is generally desirable
See Section 4.4 for additional information on auto-negotiation functionality.
This is desirable when there are unknown devices presently or potentially connected,
which will not operate correctly with full-duplex. Examples include hubs that support
because it is widely used and allows for the connection of various devices without re-
generally popular. FDX works well under most circumstances, but cannot always be

The factory (default) setting is for full-duplex on all fiber 100Mbps ports, which is
depended upon to work as expected. If full-duplex on 100Mbps will not function
properly in your setup, internal jumpers allow the mode of the Q-Series fiber
FDX @100 config 100 Mb Pin 1-2, 6-7, 9-10
11-12 100 Mb JP1-2, 7-8, 11-12 Pin 1-2, 7-8,
ettings 100Mbps Full Duplex 100Mbps Half Duplex Factory S
Jumper Settings for 10 or 100Mbps Fiber Half or Full Duplex
Figure 3.5. Fiber ports, internal jumper settings.
changing any internal jumper setting
only half-duplex by default.

connected device is half duplex and does not support full-duplex; or the connected device
3.6 Combo(3+1) ports, internal jumper settings for 10/100 RJ-45 Auto- Negotiation or 100Mb fiber fixed Half- or Full-Duplex , per port
desirable when there are unknown devices presently or potentially connected, which will
duplex on fiber 100Mbps ports, which is generally popular. Auto-Negotiation on RJ-45
setup, internal jumpers allow the speed and mode of the Q-Series Combo- quad ports to
does not support full-duplex properly) no full-duplex is better and the internal jumper
Jumper Settings for 10/100Mbps RJ-45 Auto-Negotiation, 100Mbps Fiber Half or Full Duplex

The factory (default) setting is Auto-Negotiation on all RJ-45 ports and full-
JP2 -3, 6-7, 10-11 Pin 2-3, 6-7, 10-11 Auto-Negotiation YES 10/100 Mb(RJ-45)
depended upon to work as expected. If full-duplex will not function properly in your
configuration(specially along with switches). Under certain conditions,(where the
-12 100 Mb(Fiber) JP1-2, 7-8, 11-12 Pin 1-2, 7-8, 11
and FDX on fiber port works well under most circumstances, but cannot always be
be fixed, even if the attached device may or may not support full-duplex. This is
FDX @100 config 100 Mb(Fiber) Pin 1-2, 6-7, 9-10
Figure 3.6 Combo ports, RJ-45 and Fiber internal jumper settings.
settings will permit this to be selected on a per-port basis.
changing any internal jumper settings

jumpers allow the speed and mode of the Q-Series RJ-45 (copper) quad-ports to be fixed,
duplex mode of the Q-Series fiber quad- ports to be changed, even if the attached device
Therefore, the default setting of half-duplex ( fiber ports) is generally desirable
If auto-negotiation will not function properly in your setup, internal
even if the attached device may or may not support auto-negotiation. This is desirable
operate correctly with auto-negotiation. Examples include some NICs and most Media
duplex on 10Mbps will not function properly in your setup, internal jumpers allow the
supports full-duplex. This is desirable when there are devices connected which will not
operate correctly with half-duplex. Examples include Switches that support full-duplex
duplex on all the four ports. There is no individual port duplex options for 10 Mb port.
The factory (default) setting is for half-duplex on all fiber 10Mbps
ports, which is generally popular. HDX works well under most circumstances. If half-
because it is widely used and allows for the connection of various devices without re-
3.7 Fiber 10Mb ports, internal jumper settings for 10Mb fixed Half- or Full-Duplex at all ports
not operate correctly with full-duplex or half-duplex. Examples include hubs that
when there are unknown devices presently or potentially connected, which will not
configuration.(where the connected device is half duplex and does not support full-
duplex i.e. Hub and media-converters.)
support only half-duplex by default.
only.
Converters


upply, and has a recessed male IEC connector for the AC power cord at the left-rear. A
The auto-ranging power supply supports installation environme ts where the
quency of between 47 and 63
witches incorporate an internal universal power
C 60 Hz standard power
ically, and the 16- p
c pplied with each unit shipped within the United States and Canada.
Series AC power conn
Figure 3.7 10Mbps Fiber ports internal jumper settings.
Hz. The 8-port units will consume just under 20 watts of power ty
manual power ON-OFF switch is adjacent. A six-foot 115 VA
AC voltage is from 90 to 260 volts with a power input fre
Jumper Settings for 10Mb Fiber Half or Full
port units will consume about 35 watts typically.
changing any internal jumper settings
The Magnum Quad-Series S
47-63Hz OFF 1.0-0.5A

need to be added or replaced. In cases where additional QPM cards are needed, the face
Power supply options are available to suit the Quad-Series Switches to special
high-availability g:
received from the factory
communications and/or heavy industrial-grade applications, includin
See the Appendices of this manual for more details. Use an RFQ for other variations.
equipment) are sensitive to static discharge. Use proper ESD measures
QPM Card, two 7/16 stand-offs , two #4-40 Pan-Head screws, two #4-40 bla
When connecting the Ethernet cabling, there is no need to power down the
unit. Individual segments can be connected or disconnected without concern for AC
with all required QPM modules installed. There may be situations where QPM cards
d. The following procedure
properly. The QPM Card package for field installation comes along w
from the chassis before attempting to remove
Failure to do so may result in damage to the u
* -48VDC, 24VDC & 125VDC with dual-source DC input,
Be sure the power cord is unplugged
The Magnum Q-Series Fiber Switches are normally
and/or replace any QPM cards.
and will voi he warranty.
plate for an available front-mounted slot must be remove
Headers pin.
* -48VDC, 24VDC & 125VDC with single
power-related problems or damage to the unit.
when handling port modules.
color Flat-head screws and two
descr this operation.

screws. Once these are removed, the top cover is easily lifted off the chassis base. When
PM connector sockets along with two stand-offs for each QPM card position. There are
ssembled together with the help of 20 Philips head screws. There are 7 screws located
n front-top of the unit and three screws each on the left and right edges. Remove these
Looking that there are individual
our QPM slots located on the front of the QS5116 model, whereas QS580 and QS5108
with top and bottom part and
oved, the interior of the unit is exposed.

down into the Magnum Q-Series unit, notice
Media Connector with electronic
The Magnum Q-Series chassis are combined
QPM slots in the front. (See Figure 3.9.1b).
20 Phillips Head Screws on Top
Cooling Fan Power Supply Board
the chassis top cover has been rem
Step 2.

On the bottom-front of the unit, there are two retaining screws for each QPM card slot as

connector socket slot. Align the connector pins on the bottom of
well as two other retaining screws on the rear top of the module. These four screws are
bottom side of the QPM module. (Note: After firmly attached the sockets and
the header pin, move the mounted pins slightly tilted towards the front of the
Printed Circuit card Two Set of Ten(
used to secure a QPM face plate in position. These screws are also used to secure the
individual QPM cards, which can be subjected to significant forces from the attached
Up to four front-mounted QPM cards may be installed in one Magnum 5116
Jumper Settings for HDX/FDX
p 3. Align the two headers pin on the top of the two sets of socket fixed at the
ocedure in Section 3.9.1 above.
3.9.2 Installing QPM Cards in the Magnum Q-Series
the QPM card with the connector socket inside the unit.
Fiber switch unit. Follow these steps to install a QPM.
cables. (See Figure 3.9.1c)
from the factory.
card. Each QPM
card fits into the
chassis.

e pins are not properly aligned with the holes in the header,
precisely aligned the header pins with the holes in the socket slot mounted on
the board. Slowly and carefully apply enough pressure on both rear corner of
ort slot. Some of the
dule to insert the QPM card’s pins into position. A click sound will
oper lockup of the two, see Figure 3.9.2b. (If you force determine the pr the
-out, and retaining screws. Use #4-40 Pan Head retaining
unit to be operational. When leaving QPM slots empty, always use a face
flow, safety, and operation as required by
plate (Magnum QPM-FP) to cover the slot opening in the front panel. T
he module rear part and #4-40 Flat Head (Black color)
port modules may fit easily in one port slot and be very hard to install in

nce all QPM cards have been installed (including face plates for em
Media Connector with electronic
Cooling Fan Power Supply Board
become bent and the QPM is damaged).
the chassis cover should be replaced.
FCC, CE, and other regulations.
retaining screws for front panel.
will maintain proper cooling air
QPM Module Installed inside a QS5116
installed the QPM cards inside
Fig. 3.9.2b Top View :
shows the top view of QPM
QPM down when th
panel port slot cut
screws to secure t
the QS5116.
another.

If the slot from which the QPM card has been removed is to remain unused, be

Gently pull the QPM card up and out of the connector socket (see Fig.3.9.3b).
sure to install a QPM face plate cover in it. If another QPM card is replacing
To properly remove a QPM card from the Fiber Switch, follow the 3 steps
-front of the unit there are two retaining screws for each QPM
the one that has been removed, follow the steps as described for installing a
move the front screws first and then screw
crews are used to secure a QPM card in

the power cord is unplugged.
mounted on the rear-top of the QPM to be removed.
QPM card discussed in Section 3.9.1.
card and face plate slot. These s
position (see Figure 3.9.3a). Re
below.

A Magnum Quad-Series provides switched connectivity at Ethernet wire-speed
and 10 or 100Mb separate traffic domain for fiber port to maximize bandwidth utilization
Each time a packet arrives on one of the switched ports, the decision is taken to
either filter or to forward the packet. Packets whose source and destination addresses are
on the same port segment will be filtered, constraining them to that one port and relieving
node addresses (12K for 8-port models), suitable for use in large networks. They are self-
among all of its ports. The Magnum Quad-Series supports10/100Mbs for copper media
learning, so that as nodes are added or removed or moved from one segment to another,
and network performance. A ll other ports in a Magnum
ies, but local traffic on a port will not consume any of the bandwidth on any
Magnum Quad-Series units are plug-and-play devices. There is no software
uplex mode and 10 or 100Mbps selection for the switched ports can be done through
the rest of the network from processing them. A packet whose destination address is o
another port segment will be forwarded to the appropriate port, and will not be sent to t
where it is not needed. Traffic needed for maintaining the operation of the
mode, which eliminates bad packets and enables peak performance to be achieved wh
configuration settings are user options for UP-LINK on RJ-45 quad-port. Half / Full
eries units have address table capacity of 24K
e internal functions of both are described below.
This chapter describes the functions and operation of the Quad-Series.
The Magnum Quad-Series Switches operate in the store-and-forwar
or for maintenance. The only hardware
such as occasional multi-cast packets) is forwarded to all ports.
the Quad-Port Switch automatically keeps up with node locations.
ll ports can communicate to a
configuring to be done at installation
there is heavy traffic on the network.
All 16-port Magnum Quad-S
jumper settings inside the unit. Th
t.

for 10 Mbps and 100Mbps operation.
noting Po t 1’s LK (li ich is illuminated when a proper link is made.
agnum Quad-Series Fast Ethernet copper ports can be set for either fixed
ory default setting is for auto-negotiation. At 100Mb-fixed speed,
An address-aging algorithm causes least-used addresses to fall out in favor of
new frequently-used addresses. To reset the address buffer, cycle power down-and-up.
ink status for 10 Mbps and 100Mbps operation.
The module has a manual Up-link push-button, located on the front panel next
or switching hub in the network. Verify proper Up-link push-button position by
One frequently-used application for the Magnum Quad-Switch copper ports is
backbone, or to some other remote 100Mb device. In this case, it is desirable to operate
the fiber link at 100Mb speed, and at either half- or full duplex mode depending on the
100/10 : Speed LED, ON when the speed is 100Mbps , OFF when the speed is 10 Mbps
100Mb speed or for 10/100 F/H N-way auto-negotiation per the IEEE802.3u standard. The selec ia an internal jumper (see Section 3.4 for jumper-setting
lf- or full-duplex mode by internal jumpers for each RJ-45 port
t one of them using a fiber media converter to another Switch in the network
PWR : Power LED, ON when external power is applied to the unit.
Mb RJ-45 Quad-port # 1 which it controls. It enables the port’s cable to eit
capabilities of the remote device. Standard commercially-available Fast Ethernet me
Half duplex LED, ON when the port is running full
o a user station node (push in) or to be cascaded (push out) to a 10/100Mb
100/10 FDX/HDX
4.4 Auto-negotiation, for Fast Ethernet copper ports
duplex, OFF for half duplex.
For all Magnum Quad-Series models :
nk) LED status, wh r
Figure 4.3 :
tion is made v
instructions). The fact
the user may select ha
separately.

converters mostly do not support auto-negotiation properly, and require that the switched
t collision domain. The Path Delay Value (PDV) bit-times must
Fast Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.
port to which they are connected be at 100Mb fixed speed. Attachment to 10/100 auto-
When operating in 100Mb half-duplex mode, cable distances and hop-counts
full-duplex, (2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex.
The auto-negotiation logic will attempt to operate in descending order and will norma
highest order mode that both devices can support at that time. (Since auto-
on is potentially an externally-controlled process, the original “highest order
mode” result can change at any time depending on network changes that may occur). I
the device at the other end is not an auto-negotiating device, the Quad-Switch’s RJ-45
ports will try to detect its idle signal to determine 10 or 100 speed, and will default to
or all devices and cable lengths within that domain. For Magnum Quad-Serie
connected to an another auto-negotiating device, there are 4 different speed and F/H
Auto-negotiation per-port for 802.3u-compliant switches occurs when:
the devices at both ends of the cable are capable of operation at either 10
that they are in is powered up. These are exceptions to the “negotiate at
negotiation ports typically will not work properly. The Quad-Switch’s RJ-45 ports
When Quad-Switch’s RJ-45 copper ports are set for auto-negotiation and
-- when the second of the two connected devices is powered up*, i.e.,
-- when LINK is re-established on a port after being lost temporarily.
ection 3.4)
modes selection depending on what the other device supports. These are: (1) 10
LINK – enabled” rule above, but may be occasionally encountered.
Mb or 100Mb speed and/or in full- or half-duplex mode, and can
handle this situation by changing the internal jumper settings. (see S
send/receive auto-negotiation pulses, and . . .
half-duplex at that speed per the IEEE standard.
when LINK is established for a port, or
may be limited within tha

negotiation independently on all switched ports. If the device or node on the other end of
repeater or a standard 10 Mb hub), the Quad-Switch’s RJ-45 ports will default to operate
ull-Duplex ports, which provides for a “PAUSE” packet to be transmitted
The transmitting device is commanded to stop transmitting into the Quad-switch port for
duplex, the Magnum Quad-Port Switch will negotiate to run full-duplex. If the attached
device or node doesn’t support F/H mode auto-negotiation (for example, if it is a 10 Mb
of a his is
100Mb ports are attempting to transmit to one 100Mb port, and in other protracted heav traffic situations.
to the sender when the packet buffer is nearly filled and there is danger of lost packets.
allows the available buffer space to improve, as the switch catches up with the
network t , the
The Magnum Quad-Series Switches perform half- or full-duplex mode auto
ttached cable supports F/H mode auto-negotiation or is set to operate as full-
Magnum Q- Series Switches incorporate a flow-control mechanism for Full-
sufficient time to let the Switch reduce the buffer space used. When the available free-
e d ance is only limited by the physical layer line driver and cable attenuation.
speed difference makes the 10Mb port unable to keep up. It can also occur when mu
ement the 802.3x flow control (non-
transmitter to start sending the packets. Of course, the transmitting device must also
switch prevents frames from entering the device by forcing a collision indica
on the half-duplex ports that are receiving. This temporary “collision” delay
Full-duplex Ethernet provides separate Transmit and Receive data paths,
enabling sim ovements on a port. The
to occur when data is moving from a 100Mb port to a 10 Mb port, and t
3x flow control standard in order to communicate properly during normal operation.
ssure algorithm on 10/100 Mb ports for flow control. That is, the
opology must be a “star” type, not a “bus” type. With full-duplex mode
Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a lo
burst ctivity causes the switch to save frames until its buffer memory is full. T
buffer queue increases, the Switch will send a “RESUME" packet to indicate the
ultaneous bi-directional collision-free data m
re a no collision-domain restrictions or limitations.
Magnum Q-Series Fiber Switches impl
support the 802.
at half-duplex.
traffic flow.


Siemens’) web sites and catalogs to provide guidance to network designers and installers.
over long distances (i.e., in excess of approx. 400 meters) can be achieved only
-31 9.0 5.5 2.5 2.0 14 12 5 M 4
Q -31 14 28 17.5 35 PM-SSC FX mode (0.4) 1300 9/125 -15 100Mb Single- 18+
QPM- 100Mb Multi- 2 (0.4) 1300 62.5/125 -14 -31 15 5 M FX mode V45 16 5.7
* The use of either multi-mode or single-mode fiber to operate a Note: t 100Mbps speed
n. e fiber link must be greater than the iber cable’s
Receiver Sensitivity and Transmitter Power are the parameters necessary to
The following data has been collected from component manufacturer’s (Agilent’s and
full-duplex (factory default) setting for 100Mbps fiber ports must be used,
(Attenuation = C s
s L + ED aging loss + Insertion loss + safety factor)
compute the power budget. To calculate the power budget of different fiber media
where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,
-31 14 19.5 5 5.9 17 23.5 10- FST ode (2)
MTRJ FX mode (0.4) 50/125 -23.5 -31 5.5 2.0
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
QPM- 100Mb Multi- 2 1300 62.5/125 -20 -31 9.0 3.0 15.8
installations using Magnum products, the following equations should be used:
t case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
= OPB - 1dB(for LED aging) - 1dB(for insertion loss)
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
OPB (Optical Power Budget) = PT(min) - PR(min)
if the following factors are both applied:
pa worst- se O B of t

installing a QPM; notify the carrier of any damage which you believe occurred
uring shipment or delivery. Inspect the contents of this package for any signs
Remove the QPM(s) from the shipping container. Be sure to keep the
y inal shipping container if possible. Refer
eries is the use of Quad-
Port Modules (QPMs) for flexible mixed-media connectivity to RJ-45 and fiber
media. Since the Magnum Quad-Series Switches have dual-speed capability for
ents with its individual connector type and media.
This chapter cri s each Quad-P rt Mo ule ( PM) clud appea ce,
hipping container should you need to ship any of the QPMs separately at a late
d ssing or damaged contact your supplier. If
Ethernet media types at 10 or 100Mps speed. Each QPM provides four ports
This section applies only to QPMs shipped as separate items, i.e., QPMs not
des be o d Q , in ing ran
copper ports, the quad-port interfaces are designed to support all standard
Each QPM is individually described in the following sections.
Examine the shipping container for obvious damage prior to
pes, refer to Section 1.2
of damage and ensure that the items listed below are included.
Installation instructions, with illustrations
factory installed in a Magnum Quad-Series QPM slot.
An important feature of the Magnum Quad-S
o Chapter 5 for specific return procedures.
For a list of Quad-Port Module ty
ou need to return the unit, use the orig
1 or more QPMs
s.
ate. In the event there are items mi
functionality, and status display
This package should contain:
for connecting Ethernet segm
MO (QP )
M
D ODUC
5.0 INTR
d · s r · t

Link (LK) LED tha and a
that indicates proper connectivity with the remote device when lit, and a
Lettering on the front of the module identifies it as “10 FL” to avoid confusion with other
ti-mode FL-ST-Quad-port type, “twist-lock”
-mode 10 Mbps fiber optic module equipped with
r to the 100Mb QPM-MST, but has the lettering
Lettering on the front of the module identifies it as “100 FX” to avoid confusion with
an Activity (ACT) LED indicating packets being received, a
It supports fiber optic cable distances up the
i.e., typically 2km at full-duplex and at half-
T) LED indicating packets being received, a
The Magnum QPM-MST is a multi-mode 100Mbps fiber optic quad-port
1 2 connectors. It functions as a fiber optic
t indicates proper connectivity with the remote device when lit,
module equipped with dual ST-type 100BASE-FX, and 10BASE-FL ST Connectors
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off).
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off).
DUPLEX MODE
ACT 1 2 3 4 3
3 FULL/HALF
1 FDX/HDX
LK
o lar-looking 10 Mb fiber QPMs.
hen installed in a
fiber optic cable distances up the IEEE-
100Mbps distance limits, i.e.,
2km at full-duplex and 412m
5.2.1a QPM10-MST, 10 Mbps mul
dual ST-type connectors. It looks simila
IEEE-standard 10 Mbps distance limits,
Each port has an Activity (AC
ies Fiber Switch, it supports
The Magnum QPM10-MST is a multi
“10 Mb” on the front to distinguish it.
transceiver to support 100BASE-FX
similar-looking 100Mb fiber QPMs.
network segments. W
at half-duplex.
duplex.

er connectivity with the remote device when lit, and a

modul is essentially the same, the QPM-MSC is equipped with an SC-type "snap-in"
distinguis om the multi-mode QPM-MSC, the label “Sgl.
1 mode 100Mbps fiber optic transceiver m

hs of as much as 25+ Km (see Power Budget,
(ACT) LED indicating packets being received, a
ndicate full-duplex mode when lit (or half-duplex when off). To
The Magnum QPM-MSC is a multi- 100BASE-FX Multi-Mode SC Connectors
DUPLEX MODE
3 FULL/HALF
PM-SSC.
FDX or HDX operation, and the same face-plate
similar to the QPM-MST. It has the same LEDs
indicating port activity (ACT), Link (LK), and
The QPM-SSC, when installed
h the single-mode QPM-SSC fr
M.” is at the top of the faceplate of the Q
The Magnum QPM-SSC is a
in a M um Quad-Series Fiber Switch
module equipped with a dual SC-type
supports single-mode fiber cable lengt
transceiver to the Quad-Switches,
supporting four single-mode fiber
operating at 100Mbps full-duplex,
Each port has an Activity
Link (LK) LED that indicates prop
instead of an ST-type.
single-mode 100Mbps fiber optic
It functions as a fib
network segments.
FDX/HDX LED to i
Section 4.5)
lettering.
connector.

ation. It has the same “100Mb FX” lettering on
VF-45 connector used primarily in 100Mbps fiber-to-the-desktop links. Its size is similar
e fiber cable may have a different connector,
to the MT-RJ port, but the VF-45 shell is slightly larger. When not in use, its appearance
E-FX multi-mode QPM is essentially the
same LEDs per port indicating port activity
5.2.5 QPM-MV45, 100Mbps multi-mode FX
Magnum QPM-MV45 is a quad-port multi-mode fiber FX “small-form-fac
“small-form-factor”
1 ACTIVITY LINK 2
ACT 1 2 3 4
ACT LK FDX/HDX
1 2 3 4
DUPLEX MODE
3 FULL/HALF
FULL/HALF
LK FDX/HDX
1 2 3 4
alf-duplex.
mode fiber optic quad-port module equipped
i.e.,
Magnum QPM-MTRJ is a multi-
port, but it is black in color. The MT-RJ’s
small s e and ease of connection make it a
installed in a Quad-Series Fiber Switch, it
typically 2km at full-duplex and 412m at h
The functionality of this 100BAS
(ACT), Link (LK), and FDX or HDX oper
IEEE-standard 100Mbps distance limits,
the faceplate. Note that the other end of th
typically 2km at full-duplex and 412m at
connector. It looks almost like an RJ-45
good choice for 100Mbps “fiber-to-the-
same as the ST and SC-types. It has the
standard 100Mbps distance limits, i.e.,
desktop” Ethernet connectivity. When
supports fiber optic cable distances up
door over the port hole to act as a dust
with a small-form-factor MTRJ-type
When installed in a Quad-
Series Fiber Switch, it supports fiber
optic cable distances up the IEEE-
not necessarily an MT-RJ type.
is distinctive because it has a tin
form factor
half-duplex.
cover.

eature eliminates the need for a special twisted pair crossover cable when connecting to
With the push-button in the IN (X) position, the left-most RJ-45 port is used for
cascaded and up-link connections (i.e.: a connection to another hub or switch typically).
The small size of the VF-45, about the same as an RJ-45 port, reduces the size
oviding the advantage of “future-proof” fiber
When used for segments going to workstations and other user node device connections,
The cable end is a “plug-in” connector, with both fiber strands terminated in
one housing that cannot be improperly inserted. Each port has an Activity (ACT) LED
LK) LED that indicates proper connectivity
Interface-Crossover (MDI-X) push-button to allow for one cascaded connection. This
FDX/HDX LED to indicate full-duplex mode
Each port has an Activity (ACT) LED indicating packets being received, a
Link (LK) LED that indicates proper connectivity with the remote device when lit, a
unshielded twisted pair (UTP) and shielded twisted pair (STP) cable connections.
module is equipped with a Media Dependent
10/100BASE-T, Quad Port RJ-45 Connectors
4 FULL/HALF
ACT
), 10/100Mb TP Quad-Port
1 2 3 4
Push Switch 100/10 FDX/HDX
the MDI-X push-button should be in the OUT (=) position.
indicating packets being received, a Link (
of wiring panels in wiring closets while pr
with the remote device when lit, and a
segments of any standard length. It is
when lit (or half-duplex when off).
connector, and offers 10/100 full /
on each port. The RJ-45
connector is shielded to minimize
equipped with a four-port RJ-45
emissions and will allow both
hub or another switch.

andard for up-links using twisted pair wiring, i.e., the
FULL/HALF DUPLEX(FIBER)
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off), and a
. When the TP crossover push-button is UP, the pins
functions as a fiber optic transceiver to support 100BASE-FX network segments. When
n lit, a FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when
In addition, the RJ-45 ports have a “speed” LED indicating 100Mb when lit (or 10
(TP crossover push-button DOWN) are per the standard
tances up the IEEE-
andard 100Mbps distance limits, i.e., typically 2km at full-duplex and 412m at half-
Each 3+1 combo port has an Activity (ACT) LED indicating packets being
y d a jumper on the
ived, a Link (LK) LED that indicates proper connectivity with the remote device
10/100BASE-T and 100BASE-FX Combo Quad-Port Connectors
FDX/HDX
connections to other hubs, switches, etc. IN for Up-Link
Multi-mode Connector, “Combo” Quad-Port Module
kstations and user node connections. OUT for wor
installed in a Quad-Series Fiber Switch, it supports fiber cable dis
duplex. The factor default setting is for full-duplex operation, an
peed” LED indicating 100Mb when lit (or 10 Mbps when off).
module must be moved to select half-duplex. (See Section 3.4).
For the QPM-RJ45 Crossover Push-button -
HDX/FDX
s when off). The fiber port is always 100Mbps speed.
not used.
connector. The three RJ-45 ports on the
Combo” quad-port supports three auto-
10/100Mbps FDX / HDX, and one fiber
port with 100Mbps multi-mode FX SC
same place on the QPM-RJ45 module.
receive+, 6 = receive-, other pins
right operate the same as those in the
for hubs-to-users twisted pair
transmit-, other pins not used
of the RJ-45 port are per the st
The fiber SC connector
transmit and the receive p
negotiating twisted pair ports at
The RJ-45 pins normally
off).

ST is also a 3+1 Combo quad-port. It is the same as the
module except the fiber port is single-mode. See
The QPM-FP is a blank face plate or cover plate that must be installed in any
a 3+1 Combo quad-port module. It is the
pt the multi-mode fiber port is ST-type. See
the 100Mb multi-mode-mode fiber SC-type port.
Multi-mode Connector, “Combo” Quad-Port Module
Fig. 5.2.10 Blank Face Plate
0Mb single-mode fiber port.
The Magnum QPRJ-SSC is also
QPRJ-MSC “3+1 combo” module exce
Section 5.2.3 for a description of the 10
same as the QPRJ-MSC “3+1 combo”
empty QPM slots to maintain proper
cooling air flow, and for safety, etc.
the front panel hold the QPM-FP in
Section 5.2.1 for a description of
Single
place.
Two screws underneath · The Magnum QPRJ-M

etwork environments. The installation of Magnum
tforward procedure (see INSTALLATION, Section
suggestions listed below prior to contacting your supplier. However, if you are unsure of
Series Fiber Switch unit. Be certain that each AC power cord is plugged into a
corrected. If not, go to Step 5 below. If the problem is corrected, the Magnum
help loc e, ident and co lease follow the
way impaired during installation. (About 90% of network downtime can
the procedures described in this section or if the Magnum Quad Series Fiber Switch is
the Installation Section of the applicable chapter of this manual. Also check
connected and the cables/wires have not been crimped or in some
Quad Series Fiber Switch and its associated cables are functioning properly.
to make sure that the various components of the network are interoperable.
Series Fiber Switch product, it is recommended that the problem device is
replaced with a known good device. Verify whether or not the problem is
uring installation or operation, this section is
not performing as expected, do not attempt to repair the unit; instead contact your
GarrettCom, Inc.by fax, phone or email (support@garrettcom.com) for assistance.
functioning electrical outlet. Use the PWR LEDs to verify each unit is
All Magnum Ethernet products are designed to provide reliability and
of the Magnum Quad Series Fiber Switch unit or if unknown, contact
.6); the orward and is discussed in Section 4.
intended to at ify rrect these types of problems. P
be attributed to wiring and connector problems.)
supplier for assistance or contact GarrettCom Customer Support.
6.0 TROUBLESHOOTING
consistently high performance in all n
Quad Series Fiber Switch is a straigh
Should problems develop d
2 operation is also straightf
receiving power.

6.3 ll returns Material Authorization
d. Any particular application that, when used, appears to create the problem;
stations, terminals and printers; plus, the
A record of changes that have been made to your network configuration prior
https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.
repaired units to the sender with shipping charges prepaid (see Warranty Information,
number(s). Include the date(s) that you purchased the products from your
to the occurrence of the problem. Any changes to system administration
repair products that are under warranty at no charge, and will return the warranty-
GarrettCom will carefully test and evaluate all returned products, will
Appendix A, for complete details). However, if the problem or condition causin
Failure symptoms, including a full description of the problem.
return cannot be duplicated by GarrettCom, the unit will be returned as:
Return Material Authorization (RMA) Procedure
A number, please use this URL -
Please be prepared to provide the following information.
A for repair must be accompanied by a Return
Name and phone number of your contact person.
Packing List Number (or Sales Order Number)
ve the following information readily available:
c. The components involved in the problem;
procedures should all be noted in this record.
a. The nature and duration of the problem;
various network media types being used.
No Problem Found.
b. Situations when the problem occurs;
including personal computers, work
Name of your company / institution
Serial Number (or Invoice Number)
(RMA) number. To obtain an RM
supplier.

nit.
sheet or bag for shipping protection. ( You may retain all connectors and
material. This material may cause electro-static shock damage to the u
mark the Return Material Authorization (RMA) number on the
GarrettCom, Inc. warrants its products to be free from defects in materials
und roduct that is not under warranty will
6.4 please follow these
replace components in the products that prove to be defective at no charge other
produc plication, or as a result of service or
units er warranty. Testing and repair of p arge for the testing of non-defective
on of GarrettCom, the
and mail it to Ga Please complete the warranty card as this acts as a product registration,
During this warranty period, GarrettCom will repair or, at its option,
than shipping and handling, provided that the product is returned pre-paid to
inspec ch turns out not to be
a charge for handling and
and workmanship for a period of three (3) years from the date of shi
Should you need to ship the unit back to GarrettCom,
rrettCom within two weeks of your purchase.
, in the opini This warranty will not be effective if
ting any product returned for warranty repair whi
container if available. Units should
GarrettCom reserves the right to make
47823 Westinghouse Dr.
Attn.: Customer Service
misuse, misap t has been damaged by
GarrettCom reserves the right to ch
outside of the shipping container.
ettCom.
GarrettCom, Inc.
customer (user) charge.
Installation Guide.)
modification other than by Garr
Ga tCom.
Com.
st ns:
faulty.

0 DC, 24, 100, and 125VDC POWER OPTION, THEORY OF OPERATION
s or excess outside electrical noise coming in on the DC power input lines
Consumption: all DC Model QS5108, QS5116: 30 watt typical,50 watts max.
two external power connection terminals,
B
ed as the primary power source. The DC
The –48VDC solution is particularly useful in the telecommunication industry,
her communication companies. In addition, many high availability equipment services,
acilities often use a battery backup system to maintain operations in the event of a power f
FUSE +
w re it i clude
re Providers (ISPs) and
a Quad-Series Switches-48VDC, 24VDC, 100VDC and 125VDC models are
Magnum Quad-Series Switches are easily installed in a variety of applicat
The -48VDC, 24, 100 and 125VDC power options are designed using diodes
larity connection, for example, will neither affect the Quad-Series Switches, its
The manual power “On-Off” Switch (optional) is used for powering the u
er co izing a
he s common for facilities to operate on -48VDC power. Such companies in
such as broadcasters, publishers, newspaper operations, brokerage firms and other
h the exception of the power supply, all specifications and functions of
failure. It is also frequently used for computer system backup, management and
upply, nor will it blow the fuse in the internal power supply.
pow nfigurationcapability provides an Ethernet networking solution util
gular and wireless telephone service providers, Internet Service
ecial power supply in switches with a proven track record.
DC Power Connector: 3 terminals: “ - “, “GND”, “+”
DC Power Connector: 3 terminals: “ - “, “GND”, “+”
A-
d off when it is placed into or taken out of service.
ow u P pply (Internal 125 or 100VDC Option)
where -48VDC, 24, 100 or 125VDC power is us
inside on each DC power input line behind the
so t e om an external source can
r i perate only whenever DC ies Sw tches to o
correct DC input connections. An incorrect
en to those listed in the main manual.
power is correctly applied to the two inputs.
Power Supply (Internal 24 VDC Option)
only into the unit. This allows the Qu
It protects the Quad-Series Switches from
operations monitoring equipment.
hat th power fr
DC

erate on 24VDC or 1 n the Industrial environment,
Magnum Quad-Series Switches -48VDC
In this picture, the -48VDC terminal block on the Magnum Quad-Series Switch
is located on the rear of the unit and is equipped with three (3) screw-down lead posts. It
125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage
Operation of the Magnum Quad-Series Switch with the optional -48VDC, 24V,
25VDC power. The 100 and utilities, such as electrical substations,
ery straightforward. Simply connect the
The Quad-Series Switch unit has a floating
er + or = terminal to suit the customer’s
An ON-OFF manual switch is optional for DC power. This can be used to cut
e mainly in the Industrial
is similar for 24, 100 and 125VDC options on the Quad-Series Switch. The leads are
e.
nd. Ensure that each lead is securely
ilitary equipment, etc.
100 and 125VDC power supply is identical to that of the AC-powered models.
Before connecting hot lines to the Terminal Block of –48VDC, 24,
lead from the DC supply must be connected to the post labeled “+”.
identified as negative (-), positive (+), and chassis ground (GND).
ON
The 24, 100 and 125VDC options are particularly useful i
125VDC options are mainly used in power electrical generating plants, etc. The 24VDC applications ar
VAC equipment, m environment, such as factory floor, H
off power connections, and as a RESET for the switch.
within 6 inches of the terminal block.
The actual connection procedure is v
leads to the Magnum unit, beginning with grou
ground, so the user may elect to Ground eith
installation of the -48VDC, 24, 100 and
5VDC power source leads to the DC 12 p
Quad-Series Switches. (see figure at the
right with –48VDC power as example).
where it is common for facilities to op
ower terminal block on the Magnum
This section describes the
B4.1 UL Requirements
tightened.
use.
100 or

ax.
odels.
25VDC” after the product’s standard model #. Example: Magnum QS5108-24VDC or
Power Consumption: Model QS5108 & QS5116: 30 watt typical, 50 watts max.
DC with this Dual-Source option
To order the optional –48VDC power supply factory installed, add a suffix of
“-48VDC” after the product’s standard model # Example: Magnum QS5116-48VDC.
Power Supply (Internal, 100 and 125VDC Dual-Source, model # Dual-Src1xxV)
ti he Magnum Quad-Series Fiber Switch Installation and
0 QUAD-SERIES with -48VDC, 24, 100, and 125VDC Dual-Source option
The functionality of the Magnum Quad-Series Switches -48VDC, 24, 100 or
Similarly, to order the optional 24VDC, 100VDC, or 125VDC industrial po
supply for factory installation and test, add a suffix of “–24VDC or “-100VDC” or “
Input: Two separate sources, each at 100 (90 to 160V) or 120 - 160 V rang
supply, all specifications and configuration options for the Magnum QS5116-48VDC,
The QS switch models with the internal -48VDC, 24, 100 and 125VDC Dual
Sou e p ns where a battery plant is the power
With the exception of the dual DC input power connections and the power
125VDC Dual-Source Option switches are identical to the standard AC-powered m
Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src24V)
our , and where two separate power sources are utilized in order to increase
ower Supply (Internal, -48VDC Dual-Source, model # Dual-Src48V)
r Gu de, including Appendix B “Internal DC Power Supply Option”
Please refer to Section 6.0
QS5116-24VDC, QS5116-100VDC, and QS5116-125V
simplify maintenance.
ower supply are designed for installatio rc
C1.0 SPECIFICATIONS - FOR MAG
B7.0 TROUBLESHOOTING
are iden cal to those listed in t
1 Magnum QS5116-125VDC.
operational uptime and to
P

125VDC dual source leads to the DC power terminal block on the Magnum Quad-Series Switch (shown in Figure C4.0 with 48v input as example).
he –48VDC terminal block on the Magnum Quad-Series Switch is located on
secondary power terminals as negative (B-), positive (B+). The chassis “earth” or ground
Refer to the m uration with Dual-Source Option units.
ain sections of this Installation and User Guide for a detailed description
switch will not allow power to flow from a higher voltage input to a lower voltage inpu
c) When one correct DC input is present, the switch will receive power if the other DC input is
switch or power supply internally (nor will it blow the fuse in the internal power supply
e switch will not receive power (and will not work) when both inputs are simultaneously
FUSE +
GND CHASSIS into the switch. This allows the switch
a) The switch can receive power from either input, “A” or “ ”. The switch will norm B ally dr
ause of the blocking action of the diodes. This is true even if one input connection is
rear of the unit and is equipped with five (5) screw-down lead posts (see Fig
C5.0). The primary terminals are identified as positive (A+), negative (A-), and the
(GND), is a threaded post with a #6 nut. The dual source terminal block for 24, 100
The Dual-Source DC power option is designed using diodes inside of the
GND
Reverse polarity connections, if they should accidentally cur on either inpu wil d oc t, l not d
This section describes the proper connection of the -48VDC, 24, 100 and
absent, or even if it is connected with reverse polarity or shorted or grounded.
i.e. h.
er from the DC source with the highest voltage at a given time.
the two DC power sources are not mixed together by the switc
ersed while the switch is operating from the other source.
on a Magnum QS5116 48VDC wih Dual-Source option
correctly applied to either or both of the two inputs
All Port Module options are available for config
conne n terminals) so that power B-
36-70VDC GND 36-70VDC
absent or are both incorrectly connected.
of the Magnum Quad-Series Switches.
switch on each DC power input line. A
from an external source can only flow
lines (behind the four external pow
enever DC power is
and 125VDC are similar.
diode is placed in each of the f
T

Minimum 14 AWG cable for connection to a Centralized DC power source. 1. 2. Fastening torque of the lugs on the terminal block: 9 inch pound max. 3. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4
Similarly to order “Dual-Src24V” or “Dual-Src100V” or “Dual-Src125V” as a
straightforward. Simply connect the DC leads to
Du urce Magnum Quad-Series Switch-48VDC, 24, 100
a floating ground, so the user may elect to Ground either + or = terminal to suit the
eter er supply and
e (+) and negative (-) screws. The use of Ground
itch chassis. Ensure that each lead is securely
inches apart with the first one located
order “Dual-Src-48V” as a separate ,
ts:
To order the optional Dual-Source -48VDC power supply factory installed
line item following the product model.
48V-SWITCH for model with ON-OFF switch
or Dual-Src48V-SWITCH for model with ON-OFF switch
nd 125VDC models are identical to that of the standard models. Please refer to the
pplicable sections of the “Installation and User Guide” for more information on the
Before connecting to Terminal Block of –48VDC, 24, 100 or 125VDC,
d e the lead which is more “+ve potential”. The more “+ve” voltage lead fr
The following must be adhered to in order to conform to UL requiremen
for regular model with no ON-OFF switch
Dual-Src48V for regular model with no ON-OFF switch
s u alway se a digital voltmeter to measure the output voltage of the pow
48V or –48V supply must be connected to the post labeled “+”.
separate line item following the product model.
within 6 inches of the terminal block.
(GND) is optional; it connects to the sw
The connection procedure is
the switch’s power terminals, positiv
Operation of the al-So
C5.1 UL Requirements
customer’s use.
asic switches.
tightened.