Installation and User Guide
Models 1008, 1016 and 1024


all warranties null and void. If problems are experienced with Magnum 1000
serviceable parts. Attempted service by unauthorized personnel shall render
GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a
series workgroup hub products, consult Section 5, Troubleshooting, of this
of this publication may be reproduced without prior written permission from
Installation and User Guide
Copyright 2002 GarrettCom, Inc. All rights reserved. No part
UL is a registered trademark of Underwriters Laboratories
NEBS is a trademark of Telcordia Technologies
Ethernet is a trademark of Xerox Corporation
registered trademark of GarrettCom, Inc.
Printed in the United States of America.
User Guide.
GarrettCom, Inc.
Trademarks

This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to take whatever
Please use the mailing address, phone and fax numbers and email address listed below:
47823 Westinghouse Drive Fremont, CA 94539
Radio Frequency Interference Statement
Phone (510) 438-9071
GarrettCom, Inc.
measures may be required to correct the interference.
Federal Communications Commission · Fax (510) 438-9072 · Contacting GarrettCom, Inc


was Garrett Communications). There are no changes to the content of the
as updated Appendix B with 24VDC & 125VDC option.
and added the 48V Appendix B.
material at this time
Revisions · manual

GarrettCom, Inc.offers the premium-quality Magnum line of Ethernet LAN
connectivity products with industry-standard functionality and built-in fiber
configurability. Magnum products are designed for use in demanding Carrier Class,
Industrial Grade and OEM applications where reliability is a primary consideration.
4K-Series Switches, 100 & 10Mbps, copper ports with optional fiber port, with auto-negotiating full switching performance
“Outdoor” Ethernet Switch, for temperature uncontrolled locations
6 10/100 and 2 100Mb fiber ports, can be connected in strings Mixed-Media Fiber Hub, 16-port Stackable, 10/100 auto-sensing
8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series
10Mb series and 100Mb series, both w/ optional port modules Personal Switches, 10/100Mb
All media combinations, incl. fiber ST, SC, mm., single mode
Repeater Port Modules (RPMs), 6 types for Ethernet media
Bridge Port Modules (BPMs), 4 types, for segment isolation
2, 4 and 8 Port Models Transceivers, 10Mb and 100Mb series 10Mb Mini-Transceivers and Coax Models, All Types - Apr, 02
Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing
Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper
Stackable Concentrators, SNMP optional, 13-Ports
8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb
ports,mixed-speed and mixed-media types, full switching
Mini-Concentrators, 7 Ports, Repeaters, 2-Ports
8-port, with two switched ports (1 fiber built in) Personal Hubs, 10Mb series
The Magnum Line
OVERVIEW
Stackable Hubs, SNMP Optional
Fan-Outs, 10Mb series
Performance

10BASE-FL & FOIRL. (Magnum Workgroup Hubs are physical layer standard Ethernet products,
1016 & 1024:[17.0 x 7.5 x 1.75] in, [43.2 x 19.1 x 4.5] cm Weight: 1008: 3.4 lbs, 1.6 kg 1016: 3.1 lbs, 1.4 kg 1024: 3.3 lbs, 1.5 kg Cooling method: Convection
PWR (AC power on), ACT (common activity indicator), LINK (per port)
10BASE-FL multi-mode Fiber optic - 2 km (6,562 ft)
Single-mode Fiber optic - 10 km (32,810 ft)
10BASE5 ThickNet - 500 m (1,640 ft)
FOIRL multi-mode Fiber optic - 1 km (3,281 ft)
DTE (AUI Drop Cable) - 50 m (164 ft)
10BASE-T (twisted pair) - 100 m (328 ft)
Shielded twisted pair - 150m (492 ft)
10BASE2 ThinNet (BNC) - 185 m (607 ft)
Reconnect: Occurs after 512 bits of error-free transmission.
Port 1, up-link switch for repeater-to-repeater connections.
desktop, or rack-mounting.
Partitioning: Enforced after 32 consecutive collisions.
and operate independently of all software.)
Maximum Ethernet Segment Lengths
1.1 Technical Specifications

Connector Type BNC-f DB-15 f DB-15 m Fiber-ST Fiber-ST RJ-45
Front Access yes
Partition (PART)LED yes
Receive (RX) LED yes
LINK LED n.a. n.a. n.a. yes yes yes
* The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring.
* The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring.
Three years, return to factory Made in USA
“Fiber-mm” is multi-mode cable, normally used for 10BASE-FL installations, up to
2.0Km. “Fiber-sgl.m” is single-mode cable, used for distant installations, up to 10.0Km.
** Internal termination switch for BNC, no "T" connector is required. *** MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 up-link, no crossover cable is required.
** Internal termination switch for BNC, no "T" connector is required. *** MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 up-link, no crossover cable is required.
Switch on Face Plate yes** n.a.
Connector Type BNC(f) DB-15(f) ST RJ-45
Switch on FP yes** n.a. n.a. yes***
FWD-I LED yes
FWD-X LED yes
LINK LED n.a. n.a. yes yes
(For 48VDC power input option, see Appendix B).
1.2 Specifications - Repeater Port Modules (RPMs)
1.3 Specifications - Bridge Port Modules (BPMs)
Emissions meet FCC Part 15 Class A
UL Listed (UL 1950), cUL, CE

AUI port in the rear; may optionally be ordered instead
connectors and front-mounted LEDs. Includes a basic
Stand-alone package, rack-mount brackets optional.
with an RPM or BPM in the rear port slot. Internal
bonus slot. (Note that the designated port module
universal power supply, up-link switch on port 1.
Magnum 1016 16 port 10BASE-T Hub with shielded RJ-45 connectors and front-mounted LEDs. Includes a
configured. Internal universal power supply, up-
Magnum 1024 24 port 10BASE-T Hub with shielded RJ-45 connectors and front-mounted LEDs. Includes a
configured. Internal universal power supply, up-
factory installed in the chassis, see Appendix B.
factory installed in the applicable rear-mounted
basic AUI port in the rear and one rear bonus
basic AUI port in the rear and one rear bonus
link switch on port 1. Stand-alone or rack-
link switch on port 1. Stand-alone or rack-
option, an RPM or a BPM, must also be
GarrettCom, Inc. reserves the right to change specifications, performance
slot for an optional RPM or BPM to be
slot for an optional RPM or BPM to be
mount; brackets (ears) included.
mount; brackets (ears) included.
purchased as a line item.)
characteristics and/or model offerings without notice.
1.4 Ordering Information

or delivery. Inspect the contents of this package for any signs of damage and ensure that
1 Set of metal “ears” for optional rack-mounting (Models 1016, 1024 only)
In the event there are items missing or damaged, contact the party from whom
requiring an independent Ethernet network, and will operate as self-sufficient devices to
product; notify the carrier of any damage which you believe occurred during shipment
Remove the items from the shipping container. Be sure to keep the shipping
shipping container if possible. Refer to Section 5, Troubleshooting, for specific return
Magnum 1000 Workgroup Hubs are full-featured 10BASE-T Ethernet hubs.
Examine the shipping container for obvious damage prior to installing this
you purchased the product. If the unit needs to be returned, please use the original
container should you need to ship the unit at a later date. To validate the product
Magnum 1000 Hubs provide a low cost, flexible solution for networking a small
workgroup or for adding additional nodes to an existing network via twisted pair
cabling. Magnum 1000 Hubs are well suited for small- to medium-size facilities
warranty please complete and return the enclosed Product Registration Card to
provide 10BASE-T Ethernet connectivity for all local users and devices. Small
independent networks built using Magnum 1000 Hubs are easily expanded by
2.2 Product Description - Magnum 1000-series Workgroup Hubs
cascading, adding hubs of the same or similar types to grow the network.
1 AC Power Cord (U.S. and other 115 VAC only)
1 Magnum 1008, 1016 or 1024 Workgroup Hub
2.1 Inspecting the Package and Product
1 Installation and User Guide
1 Product Registration Card
This package should contain:
GarrettCom, Inc. as soon as possible.
the items listed below are included.
procedures.

rack-mounting. Optional rack-mount brackets may be ordered, part number 1008-RMB.
The family of Magnum 1000 Workgroup Hubs is comprised of Models 1008
(pronounced “ten oh-eight”), 1016 (“ten sixteen”) and 1024 (“ten twenty-four”). These
models are equipped with 8, 16 or 24 front-mounted, shielded RJ-45 ports, respectively.
collisions, generate jam signals, extend collision fragments, and automatically partition
The Magnum 1008 Workgroup Hub, shown in Figure 2.2.1a, has eight front-
mounted, shielded RJ-45 ports and one rear-mounted AUI port. The left-most RJ-45
configuration for the Magnum 1008. The basic AUI (standard female) port may be used
for a direct connection with an AUI drop cable or for connection to any media type via
Magnum 1000 Workgroup Hubs support full Ethernet segment lengths and operate in
received. Consistent with IEEE 802.3 specifications, Magnum 1000 Hubs will detect
port (port 1) is equipped with a slide switch to allow cascading or an up-link without a
convenient monitoring of PWR, ACT (Activity) and LINK (per port). Magnum 1008s
Figure 2.2.1b shows the rear-mounted AUI port. This is the base or default
When using standard AUI cabling to connect to other Ethernet devices, it is
For models with optional 48V DC power supply built in, see Appendix B.
have an auto-ranging internal power supply, and are suitable for table-top-, wall-, or
compliance with the IEEE 802.3 specification for repeater functionality to perform
Section 3.3.2 for detailed information on the AUI port, connector pins and standard
signal amplification, re-timing, and regeneration of preamble bits for each packet
Status LEDs are located on the front panel of the Magnum 1008 for
crossover cable. Refer to section 3.3.1 for details about the up-link switch.
2.2.1 Magnum 1008 Workgroup Hub
and re-connect individual ports.
an external mini-transceiver.
cable length requirements.
Workgroup Hub · Magnum 1008

Module (RPM), the rear port can be used for direct connection to any standard Ethernet
Figure 2.2.2a). The left-most front RJ-45 port (port 1) is equipped with a slide switch to
Figure 2.2.1c). This option gives the Magnum 1008 great flexibility to easily conform
shielded RJ-45 ports, 1 rear-mounted AUI port and 1 rear Bonus Port slot (see Figure
As an alternative to the basic AUI port, it is possible (at the time of initial
order) to replace the basic AUI rear port with any Magnum Port Module (PM). (See
to any standard Ethernet media environment. When configured with a Repeater Port
media. With a Bridge Port Module (BPM), the rear port is used to bridge-isolate the
Magnum 1008 from the rest of the network, increasing bandwidth for both the local
shielded RJ-45 ports, 1 rear-mounted basic AUI port and 1 rear Bonus Port slot (see
The Magnum 1016 Workgroup Hub is equipped with 16 front-mounted,
The Magnum 1024 Workgroup Hub is equipped with 24 front-mounted,
users and the rest of the network. Refer to Section 2.4 for Magnum Port Module
(RPM-FST shown) AC Power
Basic AUI Port AC Power
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
allow cascading or an up-link without a crossover cable.
2.2.2 Magnum 1016 and 1024 Workgroup Hubs
115 - 230 VAC
simply an AUI port without any
LEDs).
2.2.2b).
Port Module · Workgroup Hub · Magnum 1016

other Ethernet devices, it is important to consider the AUI segment length, including any
In the rear, the basic AUI (standard female) port, shown in Figure 2.2.2c, may
The Bonus Port slot of a Magnum 1016 or 1024, shown in Figure 2.2.2c, may
be used for a direct connection with an AUI drop cable or for connection to any media
type via an external mini-transceiver. When using standard AUI cabling to connect to
connector pins and standard cable length requirements. (NOTE: The basic AUI port is
Magnum 1016s and 1024s great flexibility to easily conform to any standard Ethernet
port can be used for direct connection to any standard Ethernet media. With a Bridge
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
be optionally configured with any Magnum Port Module (PM). This option gives the
media environment. When configured with a Repeater Port Module (RPM), the rear
Port Module (BPM), the rear port is used to bridge-isolate the Magnum hub from the
rest of the network, increasing bandwidth for both the local users and the rest of the
convenient monitoring of PWR, ACT and LINK (per port). Magnum 1016 and 1024
hubs have auto-ranging internal power supplies, are suitable for table-top-, wall-, or
Status LEDs are located on the front panel of both the 1016 and 1024 for
cascading. Refer to Section 3.3.2 for detailed information on the basic AUI port,
rack-mounting. Rack-mount “ears” are supplied with both the Magnum 1016 and
network. Refer to Section 2.4 for Magnum Port Module information.
NOT an RPM-AUI, it is simply an AUI port without any LEDs.)
Magnum 1024 Workgroup Hubs.


application flexibility, any of the Magnum PMs may be specified at the time of order for
is necessary to have a Port Module connector cable (part number CBL-PM available as a
Figure 2.3a shows the internal layout of the Magnum 1008 for each of the two
factory configuration. It is also possible for the rear port to be re-configured in the field
Workgroup Hubs. (The Model 1024 is shown in the figure, but all rear port connections
PM. For application flexibility, any of the Magnum PMs may be specified on an order
be re-configured in the field by a trained technician to exchange or add Port Modules.
for factory configuration in the bonus port slot. It is also possible for the bonus port to
necessary to have a Port Module connector cable (part # CBL-PM available as a spare
part from GCI) in addition to the desired PM. See also Section 2.4.12, Special Option.
rear port configuration options (see section 2.2.1). Unless otherwise specified at the
are identical for the Model 1016). One rear port always has the basic AUI port in it.
The bonus port slot, in the center of the chassis rear, is available for configuring any
Figure 2.3b shows the internal layout of the Magnum 1016 and 1024
time of order, the Magnum 1008 is shipped with a basic AUI port. For greater
Optional PM card
(BPM shown) Basic AUI port
by a trained technician to exchange or add Port Modules.
spare part from GCI) in addition to the desired PM.


Module (RPM) or Bridge Port Module (BPM) in the rear bonus port. (For the 1008, this
is done by exchanging the basic AUI port for a Port Module). An RPM may be used to
multi-mode Fiber ST), SMF (Ethernet single-mode Fiber), and RJ-45 (10BASE-T UTP
Magnum 1000 Workgroup Hubs may be configured with any Repeater Port
provide connectivity, such as to a backbone, via any standard Ethernet media. A BPM
transceiver connections), DTE (DB-15 male-AUI for direct connects), ST (Ethernet
may be used to provide local-bridge isolation for the 1000 Workgroup Hub’s users.
RPMs are available for the following six Ethernet connector types: BNC
PM Ribbon cable with 16 pin headers.
May be ordered separately as part # CBL-PM)
(Included only when PM is factory installed.
(ThinNet or 10BASE2), AUI (10BASE5 or ThickNet, DB-15 female for most
RPM-DTE, RPM-FST, RPM-SMF & RPM-TP.
2.4 Bonus Port Configuration Options - RPMs and BPMs
PM card (BPM shown) Basic AUI port
and STP). They are shown in Figure 2.4a.
Use J1-RPM and J4-RPM for PMs
Use J1 and J4 for Basic AUI ports

connector for the Magnum 1000 Hubs’ bonus port slots, and are not functional as stand-

Each Port Module is normally factory installed in Magnum 1000 Hub units.
BPMs are available for the following four Ethernet media connector types:
BNC (ThinNet or 10BASE2), AUI (10BASE5 or ThickNet, DB-15 female for most
transceiver connections), ST (Ethernet multi-mode Fiber ST), and RJ-45 (10BASE-T
Magnum Port Modules provide an optional electronic assembly and media
Alternatively, PMs may sometimes be installed in the field by a trained technician.
Figure 2.4b:
alone units. Figure 2.4c shows the physical dimensions of the Port Modules.

The following is a detailed description of each Port Module.
UTP and STP). They are shown in Figure 2.4b.
Magnum BPM

terminator. To take advantage of internal termination, the slide switch should be in the
directly attached to the BNC port where it is internally terminated. When the switch is
This module is equipped with a 15 pin female AUI connector and a slide-lock,
10BASE2 coax connector. This RPM performs full IEEE 802.3 repeater functionality
The RPM-BNC module is designed with a special switch-selectable internal
used as a tap, to allow the 10BASE2 coax segment to continue on past the RPM-BNC
The RPM-BNC module includes one partition (PART) and one receive (RX)
1000 Hubs because the logic necessary to drive the LED is not included in the design.)
and performs full IEEE 802.3 repeater functionality. It is used to provide connectivity
convention. The RPM-AUI is also a "universal" Ethernet media interface as it may be
LED, which are visible from the exterior. (The PART LED is inoperative on Model
The RX LED illuminates GREEN intermittently to indicate data is being received.
termination function that eliminates the need for a "tee" connector and a 50 ohm
"DOWN" (or right-side) position. In this configuration, the 10BASE2 segment is
with a 10BASE5 (ThickNet) backbone or to any AUI segments. A transceiver is
required when connecting to a ThickNet segment and the RPM-AUI supports this
The Magnum RPM-BNC repeater module is equipped with a standard
and is used for 10BASE2 ThinNet (commonly referred to as BNC) connections.
Slide Switch Standard BNC
UP (or left): Requires "T" Connector.
connection. Magnum BPM-BNC
requires a "tee" connector
require a "tee" connector,
in the "UP" (or left-side)
position, the BNC port
(not supplied) and a 50
2.4.2 RPM-AUI
proper termination.

LEDs. The RX LED functions the same as the RX LEDs of the RPM-BNC. The PART
used with a variety of different mini-transceivers to provide connectivity to any media
female AUI, Partition LED
which has a 15-pin female connector and slide locks. The pin assignments of the two
The RPM-AUI card is equipped with Partition (PART) and Receive (RX)
connector with lock posts. (The RPM-DTE is a mating connector for the RPM-AUI
The Magnum RPM-DTE is a module equipped with a 15-pin male DTE
LED is inoperative on Model 1000 Workgroup Hubs. (Section 2.4.1 above).
hubs, and UNIX workstations. Magnum RPM-DTE
port, connector pins, and cable length requirements.
for detailed information on the AUI
are the same). The RPM-DTE card
required) using AUI drop cables to
AUI port. Examples of such devices
AUI cabling. In this situation, it is
any device that is equipped with an
segment length or distance to the
cascading. Refer to Section 3.3.2
include servers, routers, bridges,
card is also used for connecting
Ethernet devices using standard
attached device, including any
is designed to support direct
type.

dual ST-type connector. It functions as an IEEE 802.3 full repeater to support 10BASE-
the intensity of the transmitted signal. By default, the jumper is placed across pins 1 and


** When fiber cable distances of more than 2 km are selected, the minimum cable length must also be increased, as shown in the table above.
The Magnum RPM-FST is a multi-mode fiber optic module equipped with a
FL and FOIRL network segments. When used for 10BASE-FL segments, this module
10BASE-FL, FOIRL SC Connectors
for details. Magnum RPM-FSC
Magnum RPM-FST connectivity with the remote device.
2.4.4 RPM-FST (Fiber ST, Twist-lock Connector)
Receive (RX) LEDs, a LINK LED indicates proper
functionality is exactly like the RPM-FST, but
connector. Please refer back to section 2.4.4
The Magnum RPM-FSC is also a
multi-mode fiber optic repeater module. Its
2.4.5 RPM-FSC(Fiber SC, Snap-in
it is equipped with an SC-type "snap-in"
applications, it supports fiber segments
of up to 1000m in length. The RPM-
inoperative on Model 1000 Hubs) and
distances up to 2000m. For FOIRL
functionality and does not require an
supports fiber optic transmission
external transceiver device. In
FST includes full transceiver
addition to Partition (which is
Partition · Receive · Connector)

The Magnum RPM-SMF is a single-mode fiber optic module equipped with a
additional indicator, a multi-mode TX port emits light (red in color) that is in the visible
spectrum and which can be seen by looking into the port with the power on and with no
Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (2/15 - 8/60
networks. The RPM-SMF supports fiber optic transmission distances of up to 10 Km.

cable connected. The single-mode TX port emits light outside of the visible spectrum
microns for single-mode, 50/125 or 62.5/125 microns for multi-mode, where xx/xx are
RPM-FST, the label “Sgl. M.” is at the top of the faceplate of the RPM-SMF. As an
jumper, but the jumper is only to be placed across pins 5 & 6 for single-mode. The
dual ST-type connector. It functions as a full repeater to support single-mode fiber
the single-mode RPM-SMF from the multi-mode Magnum RPM-SMF
DEFAULT
the diameters of the core and the core plus the cladding respectively).
other jumper positions are not used for single-mode fiber.
2.4.6 RPM-SMF (Single-mode Fiber)
and will always look dark to the human eye.
transceiver functionality and does
LINK LEDs identical to those of
equipped with PART, RX, and
the RPM-FST. To distinguish
The RPM-SMF includes full
not require an external
transceiver device.
This module is

The RJ-45 pins normally (TP crossover switch DOWN) are per the standard for hubs-to-
the standard for up-links using twisted pair wiring, i.e., the transmit and the receive pairs
segments going to workstations and other user device connections, the switch should be
in the DOWN position. Proper switch position can be verified by noting that the port’s
The Magnum RPM-TP card supports Ethernet twisted pair segments of any
standard length. It is equipped with a single RJ-45 connector. The RJ-45 connector is
shielded to minimize emissions and will allow both unshielded twisted pair (UTP) and
The RPM-TP will support 10BASE-T unshielded twisted pair wiring (UTP)
transceiver functionality. The RPM-TP has LINK, PART (inoperative on Model 1000
pins not used. When the TP crossover switch is UP, the pins of the RJ-45 port are per
are exchanged: 1 = transmit+, 2 = transmit-, 3 = receive+, 6 = receive-, other pins not
1 LINK Partition Receive 2 3
connections (i.e.: a connection to another repeater or hub typically.) When used for
DOWN(or Right) for workstations and user connections.
With the switch in the UP position, the RPM-TP port is used for up-link
twisted pair wiring (STP) of 150m (500 ft.). This module is designed with internal
UP (or Left) for Up-Link connections to other hubs, etc.
environments with maximum segment distances up to 100m (325 ft.), or shielded
special twisted pair crossover cable. Magnum RPM-TP
LINK LED will illuminate when proper link is established.
2.4.7 RPM-TP (Twisted Pair)
module is also equipped with
shielded twisted pair (STP)
a slide switch to allow for
connections. This feature
eliminates the need for a
Hubs), and RX LEDs.
segment connections.
used.

The BPM-AUI is equipped with one FWD-I LED and one FWD-I LED, which
INTO the local Magnum hub. The FWD-X LED blinks GREEN to indicate that packets
The BPM-BNC module is designed with a special switch -selectable internal
exterior. The FWD-I LED blinks GREEN to indicate that packets are being forwarded
from a 10BASE5 (ThickNet) backbone or any Magnum BPM-AUI
AUI segment. A transceiver is required when connecting to a ThickNet segment and
are identical to those of the BPM-BNC (see Section 2.4.9). The BPM-AUI connector
supports standard IEEE signals, which are summarized in Table 3.3.2 of Section 3.3.2.
FWD-I LED 2
terminator. For switch details, refer to RPM-BNC, section 2.4.1. The BPM-BNC
module includes an FWD-I LED and an FWD-X LED, which are visible from the
designed to isolate the local segment (i.e., the users and devices connected to the
Magnum unit housing the BPM) from the connecting network (i.e., the users and
termination function that eliminates the need for a "tee" connector and a 50 ohm
referred to as BNC) connections and is Magnum BPM-BNC
devices connected through the BPM’s media connector).
are being forwarded OUT of the local Magnum hub.
the BPM-AUI supports this convention.
This local-bridge module is
connector and a slide-lock. It is self-
packets at full Ethernet wire speed. It
standard 10BASE2 coax connector.
This BPM is self-learning and filters
and forwards packets at full Ethernet
wire speed. This module is used for
equipped with a 15 pin female AUI
is used to provide segment isolation
bridge module is equipped with a
learning and filters and forwards
2.4.9 BPM-AUI

packets at full Ethernet wire speed. When used for 10BASE-FL segments, this module
functionality. The status LEDs are the same as those of the BPM-FST (Section 2.4.10).
FWD-I LED
are identical to those of the BPM-BNC (Section 2.4.9). In addition, this module has a
The BPM-TP will support 10BASE-T unshielded twisted pair wiring (UTP)
FWD-I LED
LINK LED
The BPM-TP module is also equipped with a Media Dependent Interface-
The Magnum BPM-FST is a multi-mode fiber optic local-bridge module
equipped with a dual ST-type connector. It is self-learning and filters and forwards
eliminates the need for a special twisted pair crossover cable (see RPM-TP, 2.4.7).
with maximum segment distances of 100m (325 ft.), or shielded twisted pair wiring
Crossover (MDI-X) slide switch to allow for cascaded connections. This feature
three status LEDs. FWD-I and FWD-X Magnum BPM-FST
(STP) of 150m (500 ft.). This module is designed with internal transceiver
GREEN LINK LED, that is always on when the link is operational.
and allows both unshielded twisted pair Magnum BPM-TP
(UTP) and shielded twisted pair (STP) segment connections.
10BASE-FL, FOIRL ST Connectors
transceiver device. The BPM-FST has
distances up to 2000m. For FOIRL, it
includes full transceiver functionality
card is equipped with a single RJ-
45 connector and supports standard
segments. The RJ-45 connector is
supports fiber optic transmission
supports fiber segments of up to
1000m in length. The BPM-FST
and does not require an external
shielded to minimize emissions
length Ethernet twisted pair
2.4.11 BPM-TP

Workgroup Hub with a second Port Module. The 1016 and 1024 Workgroup Hubs were
similar that of the Model 1008 change from a Basic AUI to a PM. Request special quote
connected into header J1, with the desired Port Module. This procedure requires a Port
In special cases, it may be desirable to configure the Magnum 1016 or 1024
Module connector cable (ordered separately as part number PM-CBL, or equal), and is
designed to accommodate such a configuration, and the second Bonus Port may be
configured by a trained technician and connected into header J1-RPM. In order to
install a second PM, it is necessary to replace the factory-installed Basic AUI Port,
for factory installation of a second Port Module for Models 1016 and 1024.
2.4.12 Special Option -- Second Bonus Port (Models 1016 and 1024)
configured per Workgroup Hub.

Magnum 1000 Workgroup Hubs provide a low cost method of providing
workgroups with local networking services and also interconnection into
optionally configured with any one of ten Magnum Port Modules. When
Ethernet media. Configuration with a BPM allows local-bridge isolation
Magnum 1000 Workgroup Hubs are completely inter-operable with any
Magnum 1000 Workgroup Hubs use a "star" network topology and have
Magnum 1000 Workgroup Hubs are equipped with front-mounted LEDs
to provide status about basic network activity. The per port LINK LEDs
Workgroup Hub unit to be used throughout the world. The power cable
isolated from the rest of the network, avoiding most network downtime.
Ethernet-compliant network device. Each Magnum 1000 Hub is fully
automatic per port partitioning and re-connection. A faulty segment is
Operating in a stand-alone environment as a self-sufficient network
device, Magnum 1000 Workgroup Hubs offer a low cost method of
The rear Bonus Port of the Magnum 1000 Workgroup Hubs may be
configured with an RPM, the hub may be connected to any standard
providing small- to medium-size offices and workgroups access to
compliant with IEEE 802.3 specifications for 10 Mbps CSMA/CD
offer a very simple way to verify connections at both ends of each
An internal universal AC power supply allows any Magnum 1000
a larger network via the up-link, the AUI port or the bonus port.
attaches via a standard recessed IEC-type connector in the rear
! Rear Bonus Port Provides Connectivity or Local Isolation
of the Magnum 1000 segment from the connected network.
! LEDs Simplify Network Installation and Maintenance
! Internal "Universal" Power Supply with Auto-ranging
operation, allowing full Ethernet network compatibility.
! Low cost, stand-alone 10BASE-T connectivity
! Workgroup connectivity into a larger network
! Inter-operable with other Ethernet Devices
standard Ethernet networking services.
! Robust Network Operations
attached twisted-pair cable.
2.5 Features and Benefits

refer to section 3.3.1, “Connecting Twisted Pair (RJ-45, Unshielded or Shielded). Each
Magnum 1000 Workgroup Hubs offer a great deal of flexibility and are
easily used within a variety of Ethernet environments. Magnum Workgroup Hubs will
configurations, as shown in Figure 2.6a. The number of users would likely not exceed

standard Ethernet media. Figure 2.5b shows two workgroups connected to a ThinNet
cascaded by means of the up-link switch of a port 1 (for details on the up-link switch,
Figure 2.6a: Magnum 1000 Workgroup Hub in stand-alone configuration.
Figure 2.6b: Magnum 1000 Workgroup Hubs with backbone interconnections.
Magnum 1000 Hubs can also be used to extend an existing network of any
workgroup is connected to the ThinNet through a rear-mounted BNC-type RPM. In
addition, the basic AUI port may be used to connect any standard device, such as the
(10BASE2) segment. One of the workgroups is comprised of two Magnum 1000’s
often be used to support small- to medium-size networks operating in stand-alone
twenty or so, including assorted network devices such as printers and servers.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
server shown in the figure above.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
2.6 Applications


When network performance and bandwidth are an issue, Magnum 1000’s can
Figure 2.6c: Magnum 1000 Workgroup Hubs with local-isolation via rear BPMs.
BPM with a fiber connector. Since each workgroup has its own printer and server, most
each local-bridge-isolated workgroup is connected to a central concentrator through a
of the network traffic is kept local (i.e., is contained inside of each Magnum 1000 Hub
be configured with a Bridge Port Module, as shown in Figure 2.6c. In this diagram,
segment by the BPMs) and does not consume bandwidth on the rest of the network.
Refer to section 4.2, “Magnum 1000 BPM Local Bridge Functionality”, for more
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
information about the operation of the BPMs.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Server · Server


Magnum hubs are easily mounted in a rack or on a table-top. When properly installed,
supply, and have a recessed male IEC connector for the AC power cord at the right-rear.
When connecting various Ethernet media, there is no need to power down the
unit. Individual segments of any media type can be connected or disconnected without
Installation of a Magnum 1000 Workgroup Hub is a very simple procedure.
Each Magnum 1000 Workgroup Hub’s auto-ranging power supply supports
This section gives instructions for installing the Magnum 1000 Workgroup
installed in any standard 19 inch rack. Figure 3.1: Magnum 1000’s,
A six-foot 115 VAC 60 Hz power cord is supplied with each unit shipped within the
installation environments where the AC voltage is from 90 to 260 volts with a power
(estimated). In order to power down the unit, simply unplug either end of the power
Magnum 1000 Workgroup Hubs incorporate an internal universal power
the front-mounted LED status indicators should be in plain view and easy to read.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
input frequency between 47 and 63 Hz, and will consume a maximum of 20 watts
Magnum 1008 Workgroup Hub
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
concern for AC power-related problems or damage to the unit.
3.2 Powering the Magnum 1000 Workgroup Hub
Hubs, and for connecting the various Ethernet media.
3.1 Table-Top or Rack-Mount
United states and Canada.
model 1008, order part #
brackets easily attach to
the hub, which is then
1016 and 1024. For
1008-RMB.) The
bracket. (This is
cable.

The Magnum 1000 workgroup Hub may be used as a stand-alone hub serving
the needs of a small to medium size workgroup or may be connected to a larger network
within a larger network system, the rear port(s) may be connected into a larger network,
Fiber (mm1) FOIRL ST RPM-FST, RPM-SMF, BPM-FST
Fiber (mm1) 10BASE-FL ST or SC RPM-FST, RPM-SMF, BPM-FST
Instructions for connecting the Magnum 1000 Workgroup Hub to each of the
In applications where Magnum hubs are used to provide workgroup services
The following procedure describes how to connect a 10BASE-T twisted pair
segment to the RJ-45 port on the front panel of the hub or to the RPM-TP or BPM-TP.
environment. In either case, user connectivity is achieved using twisted pair wiring,
Cat. 3 or Cat 5, UTP or STP. There may be some cases where a user device will be
The procedure is the same for both unshielded and shielded twisted pair segments.
The various media types supported and their corresponding IEEE 802.3
ThinNet 10BASE2 BNC RPM-BNC, BPM-BNC
ThickNet 10BASE5 AUI (female) RPM-AUI, BPM-AUI
Twisted Pair 10BASE-T RJ-45 RPM-TP, BPM-TP
either unshielded or shielded 10BASE-T cables and wiring may be used.
3.3.1 Connecting Twisted Pair (RJ-45, Unshielded or Shielded)
Drop Cable 10BASE5 DTE (male) RPM-DTE
Fiber (sgl.m2) * ST RPM-SMF
Media IEEE Standard Connector PM type
1 mm = multi-mode 2 sgl.m = single-mode * 10 Mb operation not currently standardized by IEEE
standards and connector types are as follows:
rather than being used to connect to a user.
3.3 Ethernet Media Connections
standard Ethernet types are given below.
connected via the AUI or Bonus Port.

for normal twisted pair cable segments from the hub port to a user device. Set
1000 directly to a backbone transceiver, the maximum AUI segment length of 50m (165 ft.) is allowed. If the Magnum 1000 is connected to a transceiver that has been cascaded
from another transceiver, the maximum AUI segment length is reduced as stated below.
(20 ft.) for every additional level of network transceiver device "dropped" or "cascaded"
Set the slide switch to the “left” (for port 1) or “down” (for PM-TP) position
network. Verify proper switch position by noting that the port’s LINK LED
Using the steps below as a guide, attach a new or existing 10BASE5 ThickNet
drop-cable directly to the AUI connector on the rear of the Magnum 1000 Workgroup
cascaded or up-link segment connections to another repeater or hub in the
The AUI port may also used for connecting to other Ethernet devices using
According to Ethernet standards, when an AUI cable is used to connect the Magnum
repeater-to-repeater connections without special cross-over connectors.
standard AUI cabling. In this type of situation, it is important to consider the AUI
equipped with an AUI connector and the AUI port of the Magnum 1000 will vary.
BPM-TP) are equipped with a cross-over slide switch to accommodate
the slide switch to the “right” (port 1) or “up” (for PM-TP) position for
The maximum transmission distance between a backbone transceiver
The RPM-AUI connector supports standard IEEE signals, which are
segment length to the attached device, including any cascading.
will illuminate when proper link is established.
port, or an AUI Port Module in a concentrator.)
3.3.2 Connecting ThickNet 10BASE5 (AUI)
Hub or on the RPM-AUI or BPM-AUI port.
from the original backbone transceiver tap.
summarized in Table 3.3.2.

connection. The PM-BNC port is specially equipped with an internal termination switch
on the front of the card (see Section 4.1 for a description of this switch). This eliminates
between FOIRL and 10BASE-FL for users is the maximum distance allowed. 10BASE-
the need to use a "tee" connector when the BNC cable is ending at the connection to this
Using the steps below as a guide, attach the 10BASE5 drop-cable directly to the
3.3.5 Connecting Fiber Optic 10BASE-FL and FOIRL (ST-type, “Twist-Lock")
Connect the ThinNet coax cable to the BNC connector on the Magnum RPM-
The following procedure applies to FOIRL and 10BASE-FL applications using
an RPM-ST or BPM-ST card with ST-type fiber connectors. (The primary difference
FL is used for a fiber segment length of up to 2000m, while FOIRL is used for fiber
2 Control In Circuit A 11 Data Out Circuit Shield
6 Voltage Common 15 Control Out Circuit B
PM. Some applications may require a "tee" connector, used as a tap, to allow the
1 Control In Circuit Shield 10 Data Out Circuit B
3 Data Out Circuit A 12 Data In Circuit B
7 Control Out Circuit A SHELL Protective Ground
BNC or BPM-BNC card in the same manner as is done for any standard BNC
4 Data In Circuit Shield 13 Voltage Plus (+)
5 Data In Circuit A 14 Voltage Shield
Pin Function Pin Function
10BASE2 coax segment to continue on past the PM-BNC connection.
8 Control Out Circuit Shield (conductive shell)
twisted pair in the AUI cable.
3.3.3 Connecting ThinNet 10BASE2 (BNC)
3.3.4 Connecting Drop Cable 10BASE5 (DTE)
9 Control In Circuit B
DTE connector on the RPM-DTE port.
segments of up to 1000m in length.)

tissue dampened in alcohol. Make certain the connectors are clean before connecting.
the Receive (RX) port of the remote device. Begin with the color-coded strand
single-mode fiber allows full bandwidth at longer distances, and may be used to connect
The same five-step procedure for multi-mode fiber ST-type applies to single-
Transmit (TX) port of the remote device. Use the non-color coded fiber strand
cable polarity. Swap the fiber cables at the Port Module connector to remedy
wrench) to tighten the fiber optic connectors as this might cause damage and result in
operating problems. Improper and excessive tightening may impair data transmission.
When using the RPM-SMF, be sure to use single-mode fiber cable. Single-
microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are
the diameters of the core and the core plus the cladding respectively). Because of this,
domain and / or power budget limitations may apply for distances over 5Km. Check
connection has been established at both ends (and when power is ON in the
unit). If LINK is not lit after cable connection, the normal cause is improper
When connecting fiber media to SMA connectors, do not over-tighten but
rather simply "finger tighten" these connections. Do not use a heavy tool (such as a
nodes up to 10 Km apart. For operation with standard half-duplex Ethernet, collision
your single-mode configuration with an experienced network designer when you use
The same five-step procedure as for fiber ST-type applies to FOIRL and
mode fiber cable has a smaller diameter than multi-mode Fiber cable (2/15 - 8/60
at regular intervals; you must use the color-coded strand on the
10BASE-FL applications using an RPM-SMA card used with SMA-type fiber
connectors. Follow the five steps as described in the Section 3.3.5 above.
mode fiber connectors. Follow the five steps listed in Section 3.3.5 above.
associated ports at each end of the fiber optic segment.
3.3.6 Connecting Fiber Optic (SMA-type, "Screw-on")*
3.3.7 Connecting Single-Mode Fiber Optic (SMF)
of the cable for this first TX-to-RX connection.
* The RPM-SMA is only available via special order.
this situation.
extended distances.
for this.


* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only
mode 10 (5) 1300 9/125 -30 -39 7 14 13 26
3.3.8 Power Budget Calculations for Magnum 1000 Series RPM’s with Fiber
Receiver Sensitivity and Transmitter Power are the parameters necessary to
full-duplex (factory default) setting for 100Mbps fiber ports must be used,
(1.75”) high. When properly installed, the front-mounted LED status indicators should
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
compute the power budget. To calculate the power budget of different fiber media
where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,
The following data has been collected from component manufacturer’s (HP’s and
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
Siemens’) web sites and catalogs to provide guidance to network designers and
installations using Magnum products, the following equations should be used:
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
OPB (Optical Power Budget) = PT(min) - PR(min)
if the following factors are both applied:
Installation of a Magnum
1000 Series Hub in a 19” rack is a
simple procedure. The units are 1U
passive Attenuation.
3.3.9 Rack-mounting
installers.


mounted brackets and screws (included with each 1000 series unit). The brackets attach
repeaters. They are compliant with IEEE 802.3 specifications for CSMA/CD 10 Mbps
operation, and support standard IEEE defined media inclusive of 10BASE-T, 10BASE-
FL, FOIRL, 10BASE2, and 10BASE5. The following describes the basic functionality.
The 23” brackets and ETSI brackets are also available (optional) for Rack-
controller functions of the Magnum 1000 Hub’s base unit, functioning together as a
be in plain view and easy to read. Rack-mount installation requires special rack-
The Magnum 1000 Workgroup Hubs operate as full-function Ethernet
to the front sides of the Hub, which is then fastened into a standard 19” rack.
Workgroup Hub 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Workgroup Hub 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Workgroup Hub 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Workgroup Hub 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
mounting purpose with Magnum 1000 Series Hubs. The 23”
with the necessary screws for the convenient to the customer.
4.1 Magnum 1000 Repeater Functionality
fully compliant Ethernet repeater.
Rack-mounting purpose. The
23” brackets are mainly being used for Huge rack-mounting
frame to provide more secure
and stability to the unit in the
are moreover looks similar to
brackets are more popular in
brackets and mostly used in
the ETSI standard industry.
consider as a standard for
The optional 23” brackets
come in a package along
and the ETSI brackets
TELCO industry.

pattern is generated on each port to create a collision condition. When a collision signal
partition any port where 32 consecutive collisions occur or after 6.5 milliseconds (msec)
of continuous transmissions. Network integrity is checked every 800 msec and segment
panel LEDs to allow for quick visual assessment of the operational condition of the hub
is processing network packets. Normally flashes to indicate data traffic.
and the network. Each Magnum 1000 Hub is equipped with PWR, ACT, and LINK
between the hub and the attached device. Each RJ-45 port is represented
received data packet of less than 96 bits (a "fragment") so that the minimum output
operation. LINK is OFF if connectivity or power is lost anywhere along
LEDs. Bonus Port RPMs are also equipped with status LEDs (see Section 2.4).
re-connection occurs after one 512-bit packet is transmitted without an error.
by its own LINK LED. LINK should always be on during normal
from one port is detected, it generates a jam pattern to the other ports.
so that the output packet contains a minimum of a 64-bit preamble.
packet to the other port is 96 bits long.
internal power supply.
the segment.

to the external segment. Figure 4.2a: Internal
module which filters and forwards packets at full Ethernet wire speed. These
attached devices are bridge-isolated from the network segment connected through the
NOT IN the address
micro-bridges are self learning and have small (256 user) address tables.
When configured with a BPM, a Magnum 1000 Workgroup Hub and its
Packet filter/forward decisions are made based on whether the
packet source is internal (originates within the local Magnum 1000) or
BPM. The bridge functionality of the BPM bridge modules is described here.

table.
4.2 Magnum 1000’s with BPM Local Bridge Functionality
table.
external (originates from upstream
forwarded to the outside only if the
an internal packet being forwarded
on the attached segment). If the
address table. Figure 4.2a shows
cases where an internal packet is
source is external, it is forwarded
packet’s source is internal, it is
destination address is not in the
Figure 4.2b show the
are shown in figures 4.2c and
filtered. When the packet’s
destination address is in the
handling of external packets
4.2d respectively. When an
address is not already in the
address table, it is written
to the inside only if the
address table.

there. This happens when a node first sends Figure 4.2c: External Packet
is in the address table, it is purged. Figure 4.2d: External Packet Filtered
Packet Source Destination Address Table Filter/Forward
servers may have heavy local traffic, but only a small amount of traffic that is
throughput. For example, a segment containing a group of workstations and
having significant local traffic, it is possible to increase overall network
This can occur if a node has physically moved to a different location.
A summary of the filtering, forwarding, and address table
Source Address Address Maintenance Action
Internal Not in table Not in table Add source to table Forward
Internal In table Not in table Nothing Forward
External Not in table In table Nothing Forward
External In table In table Purge source from table Forward
Internal Not in table In table Add source to table Filter
Internal In table In table Nothing Filter
External Not in table Not in table Nothing Filter
External In table Not in table Purge source from table Filter
address table.
maintenance performed by the BPMs is shown in Table 4.2.
the table become full, the BPM will clear all
under the 256 table addresses size. Should
those connected via the inside of the local
entries in the table by reinitializing itself.
table learns only internal addresses, i.e.,
Magnum 1000, a number typically well
a packet upon bridge initialization.
an external packet’s source address

up before bridging services are available. During this time, the BPM performs
Magnum 1000 Hubs are designed with internal auto-ranging AC power supply
isolated from the rest of the network, thus increasing the effective bandwidth
indicate link integrity with an LED. This LINK LED is normally lit. An unlit
segment. All BPMs have FWD-I and FWD-X status LEDs. The FWD-I LED
flashes when packets are forwarded into the local segment. The FWD-X LED
power needed. See Section 1.1, “Technical Specifications: Power Supply (Internal)” for
directed outside the segment. A BPM connecting this segment to the rest of
units for efficiency and for simplicity of installation and operation. See Section 3.2,
the network, as shown in Figure 4.2e, will keep the local segment traffic
LINK LED indicates a broken cable or loss of power at some point in the
“Powering the Magnum 1000 Workgroup Hub” for detailed information on the AC
For optional 48VDC internal power supply information, see Appendix B.
flashes when packets are forwarded out of the local segment.
on both the local segment and the rest of the network.
Local nodes with heavy local traffic,
through Bonus Port configured
connected to front RJ-45 ports
Magnum 1024 Workgroup Hub
with BPM (BPM-FST shown)
detailed information on the internal power supply units.
the application software.
4.3 Power Requirements
an internal self-test.
Local segment isolation

consistently high performance in all network environments. The installation of Magnum
intended to help locate, identify and correct these types of problems. Please follow the
of the procedures described in this section or if the Magnum 1000 series workgroup hub
the Installation Section of the applicable chapter of this manual. Also check
into a functioning electrical outlet. Use the PWR LEDs to verify each unit is
1000 series workgroup hub and its associated cables are functioning properly.
suggestions listed below prior to contacting your supplier. However, if you are unsure
series workgroup hub product, it is recommended that the problem device is
corrected. If not, go to Step 5 below. If the problem is corrected, Magnum
is not performing as expected, do not attempt to repair the unit; instead contact your
to make sure that the various components of the network are interoperable.
series workgroup hub unit. Be certain that each AC power cord is plugged
replaced with a known good device. Verify whether or not the problem is
1000 series workgroup hub is a straightforward procedure (see INSTALLATION,
Should problems develop during installation or operation, this section is
connected and the cables/wires have not been crimped or in some way
impaired during installation. (About 90% of network downtime can be
of the Magnum 1000 series workgroup hub unit or if unknown, contact
GarrettCom, Inc.by fax, phone or email (support@garrettcom.com) for
All Magnum Ethernet products are designed to provide reliability and
Section 2.6); the operation is also straightforward and is discussed in Section 4.
supplier for assistance or contact GarrettCom Customer Support.
attributed to wiring and connector problems.)
5.1 Before Calling for Assistance
receiving power.
assistance.

d. Any particular application that, when used, appears to create the problem;
including personal computers, workstations, terminals and printers; plus, the
number(s). Include the date(s) that you purchased the products from your
Customer Service at (510) 438-9071 during business hours in California or email to
to the occurrence of the problem. Any changes to system administration
support@garrettcom.com). When calling, please have the following information
Authorization (RMA) number. To obtain an RMA number, call GarrettCom
All returns for repair must be accompanied by a Return Material
Failure symptoms, including a full description of the problem.
Please be prepared to provide the following information.
5.3 Return Material Authorization (RMA) Procedure
Name and phone number of your contact person.
Packing List Number (or Sales Order Number)
c. The components involved in the problem;
procedures should all be noted in this record.
a. The nature and duration of the problem;
various network media types being used.
b. Situations when the problem occurs;
Name of your company / institution
Serial Number (or Invoice Number)
5.2 When Calling for Assistance
supplier.
readily available:
Your shipping address · Date of installation · Product name

material. This material may cause electro-static shock damage to the unit.
sheet or bag for shipping protection. ( You may retain all connectors and
units under warranty. Testing and repair of product that is not under warranty will
Should you need to ship the unit back to GarrettCom, please follow these
replace components in the products that prove to be defective at no charge other
product has been damaged by misuse, misapplication, or as a result of service or
repair products that are under warranty at no charge, and will return the warranty-
condition causing the return cannot be duplicated by GarrettCom, the unit will be
GarrettCom reserves the right to charge for the testing of non-defective
This warranty will not be effective if, in the opinion of GarrettCom, the
Please complete the warranty card as this acts as a product registration,
GarrettCom will carefully test and evaluate all returned products, will
than shipping and handling, provided that the product is returned pre-paid to
inspecting any product returned for warranty repair which turns out not to be
materials and workmanship for a period of three (3) years from the date of
During this warranty period, GarrettCom will repair or, at its option,
Information, Appendix A, for complete details). However, if the problem or
GarrettCom, Inc. warrants its products to be free from defects in
GarrettCom reserves the right to make a charge for handling and
repaired units to the sender with shipping charges prepaid (see Warranty
and mail it to GarrettCom within two weeks of your purchase.
No Problem Found.
5.4 Shipping and Packaging Information
Attn.: Customer Service
modification other than by GarrettCom.
213 Hammond Ave.
this Installation Guide.)
GarrettCom, Inc.
result in a customer (user) charge.
shipment by GarrettCom.
GarrettCom.
returned as:
instructions:
faulty.
Fremont, CA 94539

inside on each DC power input line behind the two external power connection terminals,
With the exception of the power supply, all specifications and functions of
Magnum 1000 Workgroup Hubs-48VDC, 24VDC & 125VDC models are identical
example, will neither effect the hub, nor its power supply internally, nor will it blow the
Disconnecting the power source is used for powering the hub on and off when
20 watts max. P.S. rating
B1.0 SPECIFICATIONS - FOR MAGNUM 1000 WORKGROUP HUBS
The -48VDC, 24VDC & 125VDC power option is designed using diodes
FUSE +
the hub from incorrect DC input connections. An incorrect polarity connection, for
B2.0 -48VDC, 24VDC & 125VDC POWER OPTION, THEORY OF
20 watts max. P.S. rating
20 watts max. P.S. rating
DC Power Connector: 3 terminals: “ - “, “GND”, “+”
DC Power Connector: 3 terminals: “ - “, “GND”, “+”
A-
Power Supply (Internal -48 VDC Option)
Power Supply (Internal 125 VDC Option)
Power Supply (Internal 24 VDC Option)
source can only flow into the hub. This
it is placed into or taken out of service.
to those listed in the main manual.
applied to the two inputs. It protects
so that the power from an external
fuse in the internal power supply.
whenever DC power is correctly
allows the hub to operate only

The solution is particularly useful in the telecommunication industry, where it
monitoring equipment. In addition, many high-availability equipment services, such as
Industrial environment, where it is common facilities to operate on 24VDC & 125VDC
substation, Electrical generating plant etc. Whereas 24VDC application is mainly in the
terminals, positive (+) and negative (-) screws. The use of Ground (GND) is optional; it
applications where -48VDC, 24VDC & 125VDC power is used as the primary power
is common for facilities to operate on -48VDC power. Such companies include regular
communication companies, and firms supplying network management and operations
are identified as negative (-), positive (+), and chassis ground (GND). The connection
source. The -48VDC, 24VDC & 125VDC power configuration provides an Ethernet
in broadcasters, publishers, heavy industrial plants, brokerage firms and others, often
This section describes the installation of the -48VDC, 24VDC &125VDC
power source leads to the -48VDC, 24VDC & 125VDC power terminal block on the
networking solution utilizing a special DC internal power supply in hubs having a
use a battery backup system to maintain operations in the event of a power failure.
The 24VDC & 125VDC solution are particularly useful in the
power. The 125VDC solution is mainly used in Utilities Industries, such as Electric
Industrial environment, such as chemical plants, paper mill, stone quarrying plant,
and wireless telephone service providers, Internet Service Providers (ISPs), other
procedure is straightforward. Simply connect the DC leads to the Switch’s power
Magnum 1000 Workgroup Hubs are easily installed in a variety of
connects to the Switch chassis. Ensure that each lead is securely tightened.
36-70VDC
Block on Magnum 1000’s-48VDC
125VDC terminal block on the Magnum 1000’s is located on the rear
of the unit and is equipped with three
(3) screw-down lead posts. The leads
Magnum 1000’s. (see figure below).
The -48VDC, 24VDC &
wastewater treatment Plant etc
B4.0 INSTALLATION
proven reliability record.

To order the optional -48VDC power supply factory installed, add a suffix of
always use a digital voltmeter to measure the output voltage of the power supply and
terminal lead from 48V or –48V Power supply must be connected to the post labeled
“-48VDC” after the product’s standard model #. Example: Magnum 1016-48VDC.
Disconnecting the DC power source is used to remove the unit from service, and as a
determine the lead which is more “+ve potential Lead”. The more “+ve” voltage
Operation of the Magnum 1000’s with the optional -48VDC, 24VDC &
125VDC power supply is identical to that of the standard AC-powered models.
Please refer to Section 6.0 for troubleshooting
power-down to RESET the hub’s electronics if needed.
Similarly for “24VDC”: Magnum 1016-24VDC.
within 6 inches of the terminal block.
The GND can be hooked at the last.
B4.1 UL Requirements
“+”.