EN
GarrettCom logo
Official user manual

GarrettCom Ethernet Switch (1024)

44 pages·604 KB·Switch·PDF·ENDEFRITNLJA
GarrettCom Ethernet Switch (1024)
Table of Contents 2 sections Revisions · 2.3Internal Connections, basic AUI Port and Port Modules ShowHide
Page 1 of the GarrettCom Ethernet Switch (1024) user manual — “Ten Series”
Page 1 · click to enlarge
Page 1
GarrettCom Ethernet Switch (1024) diagram (page 1)
Fig. 1

Magnum Workgroup Hubs

Installation and User Guide

Models 1008, 1016 and 1024

GarrettCom Ethernet Switch (1024) — Magnum Workgroup Hubs diagram (page 1)
Fig. 2 · Magnum Workgroup Hubs

“Ten Series”

Page 2 of the GarrettCom Ethernet Switch (1024) user manual — Workgroup Hubs
Page 2 · click to enlarge
Page 2

all warranties null and void. If problems are experienced with Magnum 1000

serviceable parts. Attempted service by unauthorized personnel shall render

and optional 48VDC, 24VDC &125VDC-powered models

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a

series workgroup hub products, consult Section 5, Troubleshooting, of this

of this publication may be reproduced without prior written permission from

Magnum 1008, 1016 and 1024

Installation and User Guide

Copyright 2002 GarrettCom, Inc. All rights reserved. No part

Workgroup Hubs

Part #84-00030 Rev 04/02

UL is a registered trademark of Underwriters Laboratories

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

registered trademark of GarrettCom, Inc.

Printed in the United States of America.

User Guide.

GarrettCom, Inc.

Trademarks

Page 3 of the GarrettCom Ethernet Switch (1024) user manual — email support@garrettcom.com
Page 3 · click to enlarge
Page 3

This equipment generates, uses and can radiate frequency energy and if not

installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested and

found to comply with the limits for a Class A computing device in accordance with the

specifications in Subpart J of Part 15 of FCC rules, which are designed to provide

reasonable protection against such interference when operated in a commercial

environment. Operation of this equipment in a residential area is likely to cause

interference, in which case the user at his own expense will be required to take whatever

Please use the mailing address, phone and fax numbers and email address listed below:

47823 Westinghouse Drive Fremont, CA 94539

Websitehttp://www.GarrettCom.com

Radio Frequency Interference Statement

email [email protected]

Phone (510) 438-9071

GarrettCom, Inc.

measures may be required to correct the interference.

Federal Communications Commission · Fax (510) 438-9072 · Contacting GarrettCom, Inc

Page 4 of the GarrettCom Ethernet Switch (1024) user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

Page 5 of the GarrettCom Ethernet Switch (1024) user manual — Revisions
Page 5 · click to enlarge
Page 5
Rev D 04/02Included Power Budget calculation and Rack mounting as well
Rev B 06/99This revision changed the company address to the new location
Rev C 04/01Change the company name to GarrettCom, Inc. (Formerly it
Rev A 06/95This revision is the initial release of the Magnum 1000 user

was Garrett Communications). There are no changes to the content of the

as updated Appendix B with 24VDC & 125VDC option.

and added the 48V Appendix B.

material at this time

Revisions · manual

Page 6 of the GarrettCom Ethernet Switch (1024) user manual — "DESIGNED AND MANUFACTURED IN THE USA"
Page 6 · click to enlarge
Page 6

GarrettCom, Inc.offers the premium-quality Magnum line of Ethernet LAN

connectivity products with industry-standard functionality and built-in fiber

configurability. Magnum products are designed for use in demanding Carrier Class,

Industrial Grade and OEM applications where reliability is a primary consideration.

4K-Series Switches, 100 & 10Mbps, copper ports with optional fiber port, with auto-negotiating full switching performance

“Outdoor” Ethernet Switch, for temperature uncontrolled locations

6 10/100 and 2 100Mb fiber ports, can be connected in strings Mixed-Media Fiber Hub, 16-port Stackable, 10/100 auto-sensing

8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series

10Mb series and 100Mb series, both w/ optional port modules Personal Switches, 10/100Mb

All media combinations, incl. fiber ST, SC, mm., single mode

Repeater Port Modules (RPMs), 6 types for Ethernet media

Bridge Port Modules (BPMs), 4 types, for segment isolation

2, 4 and 8 Port Models Transceivers, 10Mb and 100Mb series 10Mb Mini-Transceivers and Coax Models, All Types - Apr, 02

Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing

Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper

Stackable Concentrators, SNMP optional, 13-Ports

8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb

ports,mixed-speed and mixed-media types, full switching

The “X-line” of configurable Mi X ed Media products:

Mini-Concentrators, 7 Ports, Repeaters, 2-Ports

ETHERNET CONNECTIVITY PRODUCTS

8-port, with two switched ports (1 fiber built in) Personal Hubs, 10Mb series

"DESIGNED AND MANUFACTURED IN THE USA"

The Magnum Line

OVERVIEW

Stackable Hubs, SNMP Optional

Fan-Outs, 10Mb series

Performance

Page 7 of the GarrettCom Ethernet Switch (1024) user manual — 1.0 SPECIFICATIONS
Page 7 · click to enlarge
Page 7

10BASE-FL & FOIRL. (Magnum Workgroup Hubs are physical layer standard Ethernet products,

1016 & 1024:[17.0 x 7.5 x 1.75] in, [43.2 x 19.1 x 4.5] cm Weight: 1008: 3.4 lbs, 1.6 kg 1016: 3.1 lbs, 1.4 kg 1024: 3.3 lbs, 1.5 kg Cooling method: Convection

PWR (AC power on), ACT (common activity indicator), LINK (per port)

Dimensions1008: [8.5 x 7.75 x 1.75] in, [21.6 x 19.7 x 4.5] cm
Ethernet V1.0/V2.0 IEEE 802.310BASE-T, 10BASE5 , 10BASE2,

10BASE-FL multi-mode Fiber optic - 2 km (6,562 ft)

EnclosureHigh strength metal. Suitable for wiring closet shelf,

Single-mode Fiber optic - 10 km (32,810 ft)

Storage Temperature-5 ° to 140 ° F (-20 ° to 60 ° C)

10BASE5 ThickNet - 500 m (1,640 ft)

FOIRL multi-mode Fiber optic - 1 km (3,281 ft)

DTE (AUI Drop Cable) - 50 m (164 ft)

10BASE-T (twisted pair) - 100 m (328 ft)

Shielded twisted pair - 150m (492 ft)

10BASE2 ThinNet (BNC) - 185 m (607 ft)

Ambient Relative Humidity10% to 95% (non-condensing)

Reconnect: Occurs after 512 bits of error-free transmission.

Port 1, up-link switch for repeater-to-repeater connections.

desktop, or rack-mounting.

Partitioning: Enforced after 32 consecutive collisions.

AUID-sub 15-pin female with slide lock
Ambient Temperature32 ° to 120 ° F (0 ° to 50 ° C)

and operate independently of all software.)

TPRJ-45 shielded, female

Maximum Ethernet Segment Lengths

Other Mediavia Port Modules
AC PowerIEC recessed male
Data Rate10Mbits / sec

1.1 Technical Specifications

1.0 SPECIFICATIONS

Show 7 more labels / short text on this page
Operating Environment · Network Standards · Performance · Connectors · Packaging · Switches · LEDs
Page 8 of the GarrettCom Ethernet Switch (1024) user manual — Revisions
Page 8 · click to enlarge
Page 8
RPM TypeBNC AUI DTE Fiber-mm Fiber-sgl.m TP*

Connector Type BNC-f DB-15 f DB-15 m Fiber-ST Fiber-ST RJ-45

Front Access yes

Partition (PART)LED yes

Receive (RX) LED yes

LINK LED n.a. n.a. n.a. yes yes yes

* The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring.

* The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring.

Three years, return to factory Made in USA

“Fiber-mm” is multi-mode cable, normally used for 10BASE-FL installations, up to

2.0Km. “Fiber-sgl.m” is single-mode cable, used for distant installations, up to 10.0Km.

** Internal termination switch for BNC, no "T" connector is required. *** MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 up-link, no crossover cable is required.

** Internal termination switch for BNC, no "T" connector is required. *** MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 up-link, no crossover cable is required.

Power Consumption10 watts typical, 20 watts max. P.S. rating
AC Power ConnectorIEC-type, male recessed, rear of chassis

Switch on Face Plate yes** n.a.

BPM TypeBNC AUI Fiber TP*

Connector Type BNC(f) DB-15(f) ST RJ-45

Switch on FP yes** n.a. n.a. yes***

FWD-I LED yes

FWD-X LED yes

LINK LED n.a. n.a. yes yes

(For 48VDC power input option, see Appendix B).

Input Voltage90 to 260 VAC (auto-ranging)

1.2 Specifications - Repeater Port Modules (RPMs)

Input Frequency47 to 63 Hz (auto-ranging)

1.3 Specifications - Bridge Port Modules (BPMs)

Emissions meet FCC Part 15 Class A

UL Listed (UL 1950), cUL, CE

Show 4 more labels / short text on this page
Power Supply (Internal) · Agency Approvals · Warranty · yes***
Page 9 of the GarrettCom Ethernet Switch (1024) user manual — Magnum 1000 Workgroup Hubs
Page 9 · click to enlarge
Page 9

AUI port in the rear; may optionally be ordered instead

connectors and front-mounted LEDs. Includes a basic

Magnum 10xx-48V Designates optional 48VDC power supply to be

Stand-alone package, rack-mount brackets optional.

Magnum 10xx-pm Designates a port module (RPM or BPM) to be

with an RPM or BPM in the rear port slot. Internal

bonus slot. (Note that the designated port module

universal power supply, up-link switch on port 1.

Magnum 1016 16 port 10BASE-T Hub with shielded RJ-45 connectors and front-mounted LEDs. Includes a

configured. Internal universal power supply, up-

Magnum 1024 24 port 10BASE-T Hub with shielded RJ-45 connectors and front-mounted LEDs. Includes a

configured. Internal universal power supply, up-

factory installed in the chassis, see Appendix B.

Magnum 1008 Eight port 10BASE-T Hub with shielded RJ-45

factory installed in the applicable rear-mounted

basic AUI port in the rear and one rear bonus

basic AUI port in the rear and one rear bonus

link switch on port 1. Stand-alone or rack-

link switch on port 1. Stand-alone or rack-

Magnum 1000 Workgroup Hubs

option, an RPM or a BPM, must also be

GarrettCom, Inc. reserves the right to change specifications, performance

slot for an optional RPM or BPM to be

slot for an optional RPM or BPM to be

mount; brackets (ears) included.

mount; brackets (ears) included.

purchased as a line item.)

characteristics and/or model offerings without notice.

1.4 Ordering Information

Page 10 of the GarrettCom Ethernet Switch (1024) user manual — 2.0 INTRODUCTION
Page 10 · click to enlarge
Page 10

or delivery. Inspect the contents of this package for any signs of damage and ensure that

1 Set of metal “ears” for optional rack-mounting (Models 1016, 1024 only)

In the event there are items missing or damaged, contact the party from whom

requiring an independent Ethernet network, and will operate as self-sufficient devices to

product; notify the carrier of any damage which you believe occurred during shipment

Remove the items from the shipping container. Be sure to keep the shipping

shipping container if possible. Refer to Section 5, Troubleshooting, for specific return

Magnum 1000 Workgroup Hubs are full-featured 10BASE-T Ethernet hubs.

Examine the shipping container for obvious damage prior to installing this

you purchased the product. If the unit needs to be returned, please use the original

container should you need to ship the unit at a later date. To validate the product

Magnum 1000 Hubs provide a low cost, flexible solution for networking a small

workgroup or for adding additional nodes to an existing network via twisted pair

cabling. Magnum 1000 Hubs are well suited for small- to medium-size facilities

warranty please complete and return the enclosed Product Registration Card to

provide 10BASE-T Ethernet connectivity for all local users and devices. Small

independent networks built using Magnum 1000 Hubs are easily expanded by

2.2 Product Description - Magnum 1000-series Workgroup Hubs

cascading, adding hubs of the same or similar types to grow the network.

1 AC Power Cord (U.S. and other 115 VAC only)

1 Magnum 1008, 1016 or 1024 Workgroup Hub

2.1 Inspecting the Package and Product

1 Installation and User Guide

1 Product Registration Card

This package should contain:

GarrettCom, Inc. as soon as possible.

the items listed below are included.

2.0 INTRODUCTION

procedures.

Page 11 of the GarrettCom Ethernet Switch (1024) user manual — GARRETT
Page 11 · click to enlarge
Page 11

rack-mounting. Optional rack-mount brackets may be ordered, part number 1008-RMB.

The family of Magnum 1000 Workgroup Hubs is comprised of Models 1008

(pronounced “ten oh-eight”), 1016 (“ten sixteen”) and 1024 (“ten twenty-four”). These

models are equipped with 8, 16 or 24 front-mounted, shielded RJ-45 ports, respectively.

collisions, generate jam signals, extend collision fragments, and automatically partition

The Magnum 1008 Workgroup Hub, shown in Figure 2.2.1a, has eight front-

mounted, shielded RJ-45 ports and one rear-mounted AUI port. The left-most RJ-45

configuration for the Magnum 1008. The basic AUI (standard female) port may be used

for a direct connection with an AUI drop cable or for connection to any media type via

Magnum 1000 Workgroup Hubs support full Ethernet segment lengths and operate in

received. Consistent with IEEE 802.3 specifications, Magnum 1000 Hubs will detect

port (port 1) is equipped with a slide switch to allow cascading or an up-link without a

convenient monitoring of PWR, ACT (Activity) and LINK (per port). Magnum 1008s

Figure 2.2.1b shows the rear-mounted AUI port. This is the base or default

When using standard AUI cabling to connect to other Ethernet devices, it is

For models with optional 48V DC power supply built in, see Appendix B.

have an auto-ranging internal power supply, and are suitable for table-top-, wall-, or

compliance with the IEEE 802.3 specification for repeater functionality to perform

Section 3.3.2 for detailed information on the AUI port, connector pins and standard

signal amplification, re-timing, and regeneration of preamble bits for each packet

Status LEDs are located on the front panel of the Magnum 1008 for

crossover cable. Refer to section 3.3.1 for details about the up-link switch.

Figure 2.2.1aFront view - Magnum 1008 Workgroup Hub

2.2.1 Magnum 1008 Workgroup Hub

and re-connect individual ports.

an external mini-transceiver.

GARRETT

cable length requirements.

Workgroup Hub · Magnum 1008

Page 12 of the GarrettCom Ethernet Switch (1024) user manual — GARRETT
Page 12 · click to enlarge
Page 12
Figure 2.2.1bRear view - Magnum 1008 Workgroup Hub with the basic AUI port

Module (RPM), the rear port can be used for direct connection to any standard Ethernet

Figure 2.2.2a). The left-most front RJ-45 port (port 1) is equipped with a slide switch to

Figure 2.2.1c). This option gives the Magnum 1008 great flexibility to easily conform

information. (NOTEThe Magnum 1008’s basic AUI port is NOT an RPM-AUI, it is
Figure 2.2.1cRear view - Magnum 1008 Workgroup Hub configured with PM

shielded RJ-45 ports, 1 rear-mounted AUI port and 1 rear Bonus Port slot (see Figure

As an alternative to the basic AUI port, it is possible (at the time of initial

order) to replace the basic AUI rear port with any Magnum Port Module (PM). (See

to any standard Ethernet media environment. When configured with a Repeater Port

media. With a Bridge Port Module (BPM), the rear port is used to bridge-isolate the

Magnum 1008 from the rest of the network, increasing bandwidth for both the local

shielded RJ-45 ports, 1 rear-mounted basic AUI port and 1 rear Bonus Port slot (see

The Magnum 1016 Workgroup Hub is equipped with 16 front-mounted,

The Magnum 1024 Workgroup Hub is equipped with 24 front-mounted,

users and the rest of the network. Refer to Section 2.4 for Magnum Port Module

(RPM-FST shown) AC Power

Figure 2.2.2aFront view - Magnum 1016 Workgroup Hub

Basic AUI Port AC Power

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

allow cascading or an up-link without a crossover cable.

2.2.2 Magnum 1016 and 1024 Workgroup Hubs

115 - 230 VAC

115 - 230 VAC

simply an AUI port without any

LEDs).

2.2.2b).

GARRETT

Port Module · Workgroup Hub · Magnum 1016

Page 13 of the GarrettCom Ethernet Switch (1024) user manual — GARRETT
Page 13 · click to enlarge
Page 13

other Ethernet devices, it is important to consider the AUI segment length, including any

In the rear, the basic AUI (standard female) port, shown in Figure 2.2.2c, may

The Bonus Port slot of a Magnum 1016 or 1024, shown in Figure 2.2.2c, may

be used for a direct connection with an AUI drop cable or for connection to any media

type via an external mini-transceiver. When using standard AUI cabling to connect to

connector pins and standard cable length requirements. (NOTE: The basic AUI port is

Magnum 1016s and 1024s great flexibility to easily conform to any standard Ethernet

port can be used for direct connection to any standard Ethernet media. With a Bridge

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

be optionally configured with any Magnum Port Module (PM). This option gives the

media environment. When configured with a Repeater Port Module (RPM), the rear

Port Module (BPM), the rear port is used to bridge-isolate the Magnum hub from the

rest of the network, increasing bandwidth for both the local users and the rest of the

convenient monitoring of PWR, ACT and LINK (per port). Magnum 1016 and 1024

hubs have auto-ranging internal power supplies, are suitable for table-top-, wall-, or

Status LEDs are located on the front panel of both the 1016 and 1024 for

cascading. Refer to Section 3.3.2 for detailed information on the basic AUI port,

115. 230 VAC Basic AUI Port Configurable Bonus Port
Figure 2.2.2cRear view - Magnum 1016 and 1024 Workgroup Hubs

rack-mounting. Rack-mount “ears” are supplied with both the Magnum 1016 and

Figure 2.2.2bFront view - Magnum 1024 Workgroup Hub

network. Refer to Section 2.4 for Magnum Port Module information.

NOT an RPM-AUI, it is simply an AUI port without any LEDs.)

Magnum 1024 Workgroup Hubs.

GARRETT

Show 4 more labels / short text on this page
(RPM-FST Shown) · AC Power · Workgroup Hub · Magnum 1024
Page 14 of the GarrettCom Ethernet Switch (1024) user manual — 2.3 Internal Connections, basic AUI Port and Port Modules
Page 14 · click to enlarge
Page 14
GarrettCom Ethernet Switch (1024) — 2.3Internal Connections, basic AUI Port and Port Modules diagram (page 14)
Fig. 3 · 2.3Internal Connections, basic AUI Port and Port Mod…

application flexibility, any of the Magnum PMs may be specified at the time of order for

is necessary to have a Port Module connector cable (part number CBL-PM available as a

Figure 2.3a shows the internal layout of the Magnum 1008 for each of the two

factory configuration. It is also possible for the rear port to be re-configured in the field

Figure 2.3aModel 1008 Internal Connections, Basic AUI port and Port Module

Workgroup Hubs. (The Model 1024 is shown in the figure, but all rear port connections

PM. For application flexibility, any of the Magnum PMs may be specified on an order

be re-configured in the field by a trained technician to exchange or add Port Modules.

for factory configuration in the bonus port slot. It is also possible for the bonus port to

necessary to have a Port Module connector cable (part # CBL-PM available as a spare

part from GCI) in addition to the desired PM. See also Section 2.4.12, Special Option.

rear port configuration options (see section 2.2.1). Unless otherwise specified at the

are identical for the Model 1016). One rear port always has the basic AUI port in it.

The bonus port slot, in the center of the chassis rear, is available for configuring any

Figure 2.3b shows the internal layout of the Magnum 1016 and 1024

time of order, the Magnum 1008 is shipped with a basic AUI port. For greater

2.3 Internal Connections, basic AUI Port and Port Modules

Optional PM card

(BPM shown) Basic AUI port

by a trained technician to exchange or add Port Modules.

spare part from GCI) in addition to the desired PM.

Page 15 of the GarrettCom Ethernet Switch (1024) user manual — NOTE:
Page 15 · click to enlarge
Page 15
GarrettCom Ethernet Switch (1024) — 2.3Internal Connections, basic AUI Port and Port Modules diagram (page 15)
Fig. 4 · 2.3Internal Connections, basic AUI Port and Port Mod…

Module (RPM) or Bridge Port Module (BPM) in the rear bonus port. (For the 1008, this

is done by exchanging the basic AUI port for a Port Module). An RPM may be used to

multi-mode Fiber ST), SMF (Ethernet single-mode Fiber), and RJ-45 (10BASE-T UTP

Figure 2.3bModel 1024 Internal Connections, Basic AUI port and Bonus Port

Magnum 1000 Workgroup Hubs may be configured with any Repeater Port

provide connectivity, such as to a backbone, via any standard Ethernet media. A BPM

transceiver connections), DTE (DB-15 male-AUI for direct connects), ST (Ethernet

may be used to provide local-bridge isolation for the 1000 Workgroup Hub’s users.

RPMs are available for the following six Ethernet connector types: BNC

PM Ribbon cable with 16 pin headers.

May be ordered separately as part # CBL-PM)

(Included only when PM is factory installed.

(ThinNet or 10BASE2), AUI (10BASE5 or ThickNet, DB-15 female for most

Figure 2.4aMagnum RPM Cards: RPM-BNC, RPM-AUI,

RPM-DTE, RPM-FST, RPM-SMF & RPM-TP.

2.4 Bonus Port Configuration Options - RPMs and BPMs

Bonus port for optional

PM card (BPM shown) Basic AUI port

and STP). They are shown in Figure 2.4a.

Use J1-RPM and J4-RPM for PMs

Use J1 and J4 for Basic AUI ports

NOTE:

Page 16 of the GarrettCom Ethernet Switch (1024) user manual — Approx. 2 inches (5.1 cm)
Page 16 · click to enlarge
Page 16

BPM-BNC, BPM-

connector for the Magnum 1000 Hubs’ bonus port slots, and are not functional as stand-

GarrettCom Ethernet Switch (1024) — BPM-BNC, BPM- diagram (page 16)
Fig. 5
CardsBPM-TP,

Each Port Module is normally factory installed in Magnum 1000 Hub units.

BPMs are available for the following four Ethernet media connector types:

BNC (ThinNet or 10BASE2), AUI (10BASE5 or ThickNet, DB-15 female for most

transceiver connections), ST (Ethernet multi-mode Fiber ST), and RJ-45 (10BASE-T

Magnum Port Modules provide an optional electronic assembly and media

Alternatively, PMs may sometimes be installed in the field by a trained technician.

ST, BPM-AUI

Figure 2.4b:

Figure 2.4cPhysical Dimensions of Magnum Port Modules

alone units. Figure 2.4c shows the physical dimensions of the Port Modules.

Approx. 2 inches (5.1 cm)

GarrettCom Ethernet Switch (1024) — Approx. 2 inches (5.1 cm) diagram (page 16)
Fig. 6 · Approx. 2 inches (5.1 cm)

The following is a detailed description of each Port Module.

UTP and STP). They are shown in Figure 2.4b.

Approx. 2 inches (5.1 cm)

Magnum BPM

Page 17 of the GarrettCom Ethernet Switch (1024) user manual — 2.4.1 RPM-BNC
Page 17 · click to enlarge
Page 17

terminator. To take advantage of internal termination, the slide switch should be in the

directly attached to the BNC port where it is internally terminated. When the switch is

This module is equipped with a 15 pin female AUI connector and a slide-lock,

10BASE2 coax connector. This RPM performs full IEEE 802.3 repeater functionality

The RPM-BNC module is designed with a special switch-selectable internal

used as a tap, to allow the 10BASE2 coax segment to continue on past the RPM-BNC

The RPM-BNC module includes one partition (PART) and one receive (RX)

1000 Hubs because the logic necessary to drive the LED is not included in the design.)

and performs full IEEE 802.3 repeater functionality. It is used to provide connectivity

convention. The RPM-AUI is also a "universal" Ethernet media interface as it may be

LED, which are visible from the exterior. (The PART LED is inoperative on Model

The RX LED illuminates GREEN intermittently to indicate data is being received.

termination function that eliminates the need for a "tee" connector and a 50 ohm

"DOWN" (or right-side) position. In this configuration, the 10BASE2 segment is

with a 10BASE5 (ThickNet) backbone or to any AUI segments. A transceiver is

required when connecting to a ThickNet segment and the RPM-AUI supports this

The Magnum RPM-BNC repeater module is equipped with a standard

and is used for 10BASE2 ThinNet (commonly referred to as BNC) connections.

Slide Switch Standard BNC

DOWN (or right)Internally Terminated

UP (or left): Requires "T" Connector.

connection. Magnum BPM-BNC

requires a "tee" connector

require a "tee" connector,

in the "UP" (or left-side)

position, the BNC port

(not supplied) and a 50

2.4.1 RPM-BNC

2.4.2 RPM-AUI

proper termination.

Show 6 more labels / short text on this page
Partition LED · Receive LED · Internal Termination · 10BASE2 Connector · Certain applications may · ohm terminator for
Page 18 of the GarrettCom Ethernet Switch (1024) user manual — 2.4.3 RPM-DTE
Page 18 · click to enlarge
Page 18

LEDs. The RX LED functions the same as the RX LEDs of the RPM-BNC. The PART

used with a variety of different mini-transceivers to provide connectivity to any media

female AUI, Partition LED

which has a 15-pin female connector and slide locks. The pin assignments of the two

The RPM-AUI card is equipped with Partition (PART) and Receive (RX)

connector with lock posts. (The RPM-DTE is a mating connector for the RPM-AUI

The Magnum RPM-DTE is a module equipped with a 15-pin male DTE

LED is inoperative on Model 1000 Workgroup Hubs. (Section 2.4.1 above).

Magnum RPM-AUI

hubs, and UNIX workstations. Magnum RPM-DTE

port, connector pins, and cable length requirements.

for detailed information on the AUI

are the same). The RPM-DTE card

required) using AUI drop cables to

AUI port. Examples of such devices

AUI cabling. In this situation, it is

any device that is equipped with an

segment length or distance to the

cascading. Refer to Section 3.3.2

include servers, routers, bridges,

card is also used for connecting

Ethernet devices using standard

attached device, including any

is designed to support direct

2.4.3 RPM-DTE

type.

Show 9 more labels / short text on this page
Standard 15-pin · male "AUI" · Receive LED · Partition LED · Receive LED · Standard 15-pin · with slide-lock · The Magnum RPM-AUI · connections (no transceiver
Page 19 of the GarrettCom Ethernet Switch (1024) user manual — SUPPORTED
Page 19 · click to enlarge
Page 19

dual ST-type connector. It functions as an IEEE 802.3 full repeater to support 10BASE-

the intensity of the transmitted signal. By default, the jumper is placed across pins 1 and

GarrettCom Ethernet Switch (1024) — 2.3Internal Connections, basic AUI Port and Port Modules diagram (page 19)
Fig. 7 · 2.3Internal Connections, basic AUI Port and Port Mod…
GarrettCom Ethernet Switch (1024) — 2.3Internal Connections, basic AUI Port and Port Modules diagram (page 19)
Fig. 8 · 2.3Internal Connections, basic AUI Port and Port Mod…

** When fiber cable distances of more than 2 km are selected, the minimum cable length must also be increased, as shown in the table above.

The Magnum RPM-FST is a multi-mode fiber optic module equipped with a

FL and FOIRL network segments. When used for 10BASE-FL segments, this module

10BASE-FL, FOIRL SC Connectors

for details. Magnum RPM-FSC

Magnum RPM-FST connectivity with the remote device.

1 LINK

2.4.4 RPM-FST (Fiber ST, Twist-lock Connector)

Receive (RX) LEDs, a LINK LED indicates proper

functionality is exactly like the RPM-FST, but

1. 2 0 - 2 km* 3 - 4 0.5 - 3 km** 5 - 6 1.5 - 4 km** * When distances of less than 2 km are needed, the jumper should be placed across pins 1 and 2.

connector. Please refer back to section 2.4.4

The Magnum RPM-FSC is also a

multi-mode fiber optic repeater module. Its

2.4.5 RPM-FSC(Fiber SC, Snap-in

it is equipped with an SC-type "snap-in"

applications, it supports fiber segments

2. The jumper may be set as follows to accommodate distances of up to 4 km:

of up to 1000m in length. The RPM-

inoperative on Model 1000 Hubs) and

JUMPER ACROSS DISTANCES

distances up to 2000m. For FOIRL

functionality and does not require an

supports fiber optic transmission

external transceiver device. In

FST includes full transceiver

addition to Partition (which is

SUPPORTED

Partition · Receive · Connector)

Page 20 of the GarrettCom Ethernet Switch (1024) user manual — SUPPORTED
Page 20 · click to enlarge
Page 20

The Magnum RPM-SMF is a single-mode fiber optic module equipped with a

additional indicator, a multi-mode TX port emits light (red in color) that is in the visible

spectrum and which can be seen by looking into the port with the power on and with no

Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (2/15 - 8/60

networks. The RPM-SMF supports fiber optic transmission distances of up to 10 Km.

GarrettCom Ethernet Switch (1024) — 2.3Internal Connections, basic AUI Port and Port Modules diagram (page 20)
Fig. 9 · 2.3Internal Connections, basic AUI Port and Port Mod…

cable connected. The single-mode TX port emits light outside of the visible spectrum

microns for single-mode, 50/125 or 62.5/125 microns for multi-mode, where xx/xx are

RPM-FST, the label “Sgl. M.” is at the top of the faceplate of the RPM-SMF. As an

jumper, but the jumper is only to be placed across pins 5 & 6 for single-mode. The

dual ST-type connector. It functions as a full repeater to support single-mode fiber

the single-mode RPM-SMF from the multi-mode Magnum RPM-SMF

J1

DEFAULT

the diameters of the core and the core plus the cladding respectively).

other jumper positions are not used for single-mode fiber.

2.4.6 RPM-SMF (Single-mode Fiber)

and will always look dark to the human eye.

1. 2 not used
3. 4 not used
5. 6 0 - 10 km

JUMPER ACROSS DISTANCES

transceiver functionality and does

LINK LEDs identical to those of

equipped with PART, RX, and

the RPM-FST. To distinguish

The RPM-SMF includes full

not require an external

transceiver device.

SUPPORTED

This module is

Page 21 of the GarrettCom Ethernet Switch (1024) user manual — MDI-X
Page 21 · click to enlarge
Page 21

The RJ-45 pins normally (TP crossover switch DOWN) are per the standard for hubs-to-

the standard for up-links using twisted pair wiring, i.e., the transmit and the receive pairs

segments going to workstations and other user device connections, the switch should be

in the DOWN position. Proper switch position can be verified by noting that the port’s

users twisted pair wiring1 = receive+, 2 = receive-, 3 = transmit+, 6 = transmit-, other

The Magnum RPM-TP card supports Ethernet twisted pair segments of any

standard length. It is equipped with a single RJ-45 connector. The RJ-45 connector is

shielded to minimize emissions and will allow both unshielded twisted pair (UTP) and

The RPM-TP will support 10BASE-T unshielded twisted pair wiring (UTP)

transceiver functionality. The RPM-TP has LINK, PART (inoperative on Model 1000

pins not used. When the TP crossover switch is UP, the pins of the RJ-45 port are per

are exchanged: 1 = transmit+, 2 = transmit-, 3 = receive+, 6 = receive-, other pins not

1 LINK Partition Receive 2 3

connections (i.e.: a connection to another repeater or hub typically.) When used for

DOWN(or Right) for workstations and user connections.

With the switch in the UP position, the RPM-TP port is used for up-link

twisted pair wiring (STP) of 150m (500 ft.). This module is designed with internal

UP (or Left) for Up-Link connections to other hubs, etc.

environments with maximum segment distances up to 100m (325 ft.), or shielded

special twisted pair crossover cable. Magnum RPM-TP

LINK LED will illuminate when proper link is established.

MDI-X

2.4.7 RPM-TP (Twisted Pair)

module is also equipped with

shielded twisted pair (STP)

a slide switch to allow for

connections. This feature

eliminates the need for a

Hubs), and RX LEDs.

segment connections.

used.

Show 6 more labels / short text on this page
Shielded RJ-45 · Connector · Cross-Over · Slide Switch · The RPM-TP · cascaded or up-link
Page 22 of the GarrettCom Ethernet Switch (1024) user manual — 2.4.8 BPM-BNC
Page 22 · click to enlarge
Page 22

The BPM-AUI is equipped with one FWD-I LED and one FWD-I LED, which

FWD-X LED

INTO the local Magnum hub. The FWD-X LED blinks GREEN to indicate that packets

FWD-I LED 2

The BPM-BNC module is designed with a special switch -selectable internal

exterior. The FWD-I LED blinks GREEN to indicate that packets are being forwarded

from a 10BASE5 (ThickNet) backbone or any Magnum BPM-AUI

AUI segment. A transceiver is required when connecting to a ThickNet segment and

are identical to those of the BPM-BNC (see Section 2.4.9). The BPM-AUI connector

supports standard IEEE signals, which are summarized in Table 3.3.2 of Section 3.3.2.

FWD-X LED

FWD-I LED 2

terminator. For switch details, refer to RPM-BNC, section 2.4.1. The BPM-BNC

module includes an FWD-I LED and an FWD-X LED, which are visible from the

designed to isolate the local segment (i.e., the users and devices connected to the

Magnum unit housing the BPM) from the connecting network (i.e., the users and

termination function that eliminates the need for a "tee" connector and a 50 ohm

referred to as BNC) connections and is Magnum BPM-BNC

devices connected through the BPM’s media connector).

are being forwarded OUT of the local Magnum hub.

the BPM-AUI supports this convention.

This local-bridge module is

connector and a slide-lock. It is self-

packets at full Ethernet wire speed. It

standard 10BASE2 coax connector.

This BPM is self-learning and filters

and forwards packets at full Ethernet

wire speed. This module is used for

equipped with a 15 pin female AUI

is used to provide segment isolation

bridge module is equipped with a

learning and filters and forwards

2.4.8 BPM-BNC

2.4.9 BPM-AUI

Show 9 more labels / short text on this page
Internal Termination · Slide Switch · 1 Standard 15-pin · 10BASE2 Connector · Standard BNC · female AUI · with slide-lock · The Magnum BPM-BNC · 10BASE2 ThinNet (commonly
Page 23 of the GarrettCom Ethernet Switch (1024) user manual — 2.4.10 BPM-FST
Page 23 · click to enlarge
Page 23

packets at full Ethernet wire speed. When used for 10BASE-FL segments, this module

functionality. The status LEDs are the same as those of the BPM-FST (Section 2.4.10).

FWD-X LED

FWD-I LED

are identical to those of the BPM-BNC (Section 2.4.9). In addition, this module has a

FWD-X LED

The BPM-TP will support 10BASE-T unshielded twisted pair wiring (UTP)

LINK LED

FWD-I LED

LINK LED

The BPM-TP module is also equipped with a Media Dependent Interface-

The Magnum BPM-FST is a multi-mode fiber optic local-bridge module

equipped with a dual ST-type connector. It is self-learning and filters and forwards

eliminates the need for a special twisted pair crossover cable (see RPM-TP, 2.4.7).

with maximum segment distances of 100m (325 ft.), or shielded twisted pair wiring

Crossover (MDI-X) slide switch to allow for cascaded connections. This feature

three status LEDs. FWD-I and FWD-X Magnum BPM-FST

(STP) of 150m (500 ft.). This module is designed with internal transceiver

GREEN LINK LED, that is always on when the link is operational.

and allows both unshielded twisted pair Magnum BPM-TP

(UTP) and shielded twisted pair (STP) segment connections.

10BASE-FL, FOIRL ST Connectors

transceiver device. The BPM-FST has

distances up to 2000m. For FOIRL, it

includes full transceiver functionality

card is equipped with a single RJ-

45 connector and supports standard

segments. The RJ-45 connector is

supports fiber optic transmission

supports fiber segments of up to

1000m in length. The BPM-FST

and does not require an external

shielded to minimize emissions

length Ethernet twisted pair

2.4.10 BPM-FST

2.4.11 BPM-TP

Show 5 more labels / short text on this page
MDI-X Cross-over · Slide Switch · Shielded RJ-45 · Connector · The Magnum BPM-TP
Page 24 of the GarrettCom Ethernet Switch (1024) user manual — 2.3Internal Connections, basic AUI Port and Port Modules
Page 24 · click to enlarge
Page 24

Workgroup Hub with a second Port Module. The 1016 and 1024 Workgroup Hubs were

similar that of the Model 1008 change from a Basic AUI to a PM. Request special quote

connected into header J1, with the desired Port Module. This procedure requires a Port

In special cases, it may be desirable to configure the Magnum 1016 or 1024

Module connector cable (ordered separately as part number PM-CBL, or equal), and is

designed to accommodate such a configuration, and the second Bonus Port may be

configured by a trained technician and connected into header J1-RPM. In order to

install a second PM, it is necessary to replace the factory-installed Basic AUI Port,

for factory installation of a second Port Module for Models 1016 and 1024.

2.4.12 Special Option -- Second Bonus Port (Models 1016 and 1024)

configured per Workgroup Hub.

Page 25 of the GarrettCom Ethernet Switch (1024) user manual — 2.3Internal Connections, basic AUI Port and Port Modules
Page 25 · click to enlarge
Page 25

Magnum 1000 Workgroup Hubs provide a low cost method of providing

workgroups with local networking services and also interconnection into

optionally configured with any one of ten Magnum Port Modules. When

Ethernet media. Configuration with a BPM allows local-bridge isolation

Magnum 1000 Workgroup Hubs are completely inter-operable with any

Magnum 1000 Workgroup Hubs use a "star" network topology and have

Magnum 1000 Workgroup Hubs are equipped with front-mounted LEDs

to provide status about basic network activity. The per port LINK LEDs

Workgroup Hub unit to be used throughout the world. The power cable

isolated from the rest of the network, avoiding most network downtime.

Ethernet-compliant network device. Each Magnum 1000 Hub is fully

automatic per port partitioning and re-connection. A faulty segment is

Operating in a stand-alone environment as a self-sufficient network

device, Magnum 1000 Workgroup Hubs offer a low cost method of

The rear Bonus Port of the Magnum 1000 Workgroup Hubs may be

configured with an RPM, the hub may be connected to any standard

providing small- to medium-size offices and workgroups access to

compliant with IEEE 802.3 specifications for 10 Mbps CSMA/CD

offer a very simple way to verify connections at both ends of each

An internal universal AC power supply allows any Magnum 1000

a larger network via the up-link, the AUI port or the bonus port.

attaches via a standard recessed IEC-type connector in the rear

! Rear Bonus Port Provides Connectivity or Local Isolation

of the Magnum 1000 segment from the connected network.

! LEDs Simplify Network Installation and Maintenance

! Internal "Universal" Power Supply with Auto-ranging

operation, allowing full Ethernet network compatibility.

! Low cost, stand-alone 10BASE-T connectivity

! Workgroup connectivity into a larger network

! Inter-operable with other Ethernet Devices

standard Ethernet networking services.

! Robust Network Operations

attached twisted-pair cable.

2.5 Features and Benefits

Page 26 of the GarrettCom Ethernet Switch (1024) user manual — 2.3Internal Connections, basic AUI Port and Port Modules
Page 26 · click to enlarge
Page 26

refer to section 3.3.1, “Connecting Twisted Pair (RJ-45, Unshielded or Shielded). Each

Magnum 1000 Workgroup Hubs offer a great deal of flexibility and are

easily used within a variety of Ethernet environments. Magnum Workgroup Hubs will

configurations, as shown in Figure 2.6a. The number of users would likely not exceed

GarrettCom Ethernet Switch (1024) — 2.3Internal Connections, basic AUI Port and Port Modules diagram (page 26)
Fig. 10 · 2.3Internal Connections, basic AUI Port and Port Mod…

standard Ethernet media. Figure 2.5b shows two workgroups connected to a ThinNet

cascaded by means of the up-link switch of a port 1 (for details on the up-link switch,

Figure 2.6a: Magnum 1000 Workgroup Hub in stand-alone configuration.

Figure 2.6b: Magnum 1000 Workgroup Hubs with backbone interconnections.

Magnum 1000 Hubs can also be used to extend an existing network of any

workgroup is connected to the ThinNet through a rear-mounted BNC-type RPM. In

addition, the basic AUI port may be used to connect any standard device, such as the

(10BASE2) segment. One of the workgroups is comprised of two Magnum 1000’s

often be used to support small- to medium-size networks operating in stand-alone

twenty or so, including assorted network devices such as printers and servers.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

server shown in the figure above.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

2.6 Applications

Page 27 of the GarrettCom Ethernet Switch (1024) user manual — 2.3Internal Connections, basic AUI Port and Port Modules
Page 27 · click to enlarge
Page 27
GarrettCom Ethernet Switch (1024) — 2.3Internal Connections, basic AUI Port and Port Modules diagram (page 27)
Fig. 11 · 2.3Internal Connections, basic AUI Port and Port Mod…

When network performance and bandwidth are an issue, Magnum 1000’s can

Figure 2.6c: Magnum 1000 Workgroup Hubs with local-isolation via rear BPMs.

BPM with a fiber connector. Since each workgroup has its own printer and server, most

each local-bridge-isolated workgroup is connected to a central concentrator through a

of the network traffic is kept local (i.e., is contained inside of each Magnum 1000 Hub

be configured with a Bridge Port Module, as shown in Figure 2.6c. In this diagram,

segment by the BPMs) and does not consume bandwidth on the rest of the network.

Refer to section 4.2, “Magnum 1000 BPM Local Bridge Functionality”, for more

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

information about the operation of the BPMs.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Server · Server

Page 28 of the GarrettCom Ethernet Switch (1024) user manual — 3.0 INSTALLATION
Page 28 · click to enlarge
Page 28
GarrettCom Ethernet Switch (1024) — 2.3Internal Connections, basic AUI Port and Port Modules diagram (page 28)
Fig. 12 · 2.3Internal Connections, basic AUI Port and Port Mod…

Magnum hubs are easily mounted in a rack or on a table-top. When properly installed,

supply, and have a recessed male IEC connector for the AC power cord at the right-rear.

When connecting various Ethernet media, there is no need to power down the

unit. Individual segments of any media type can be connected or disconnected without

Installation of a Magnum 1000 Workgroup Hub is a very simple procedure.

Each Magnum 1000 Workgroup Hub’s auto-ranging power supply supports

This section gives instructions for installing the Magnum 1000 Workgroup

installed in any standard 19 inch rack. Figure 3.1: Magnum 1000’s,

A six-foot 115 VAC 60 Hz power cord is supplied with each unit shipped within the

installation environments where the AC voltage is from 90 to 260 volts with a power

(estimated). In order to power down the unit, simply unplug either end of the power

Magnum 1000 Workgroup Hubs incorporate an internal universal power

the front-mounted LED status indicators should be in plain view and easy to read.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

input frequency between 47 and 63 Hz, and will consume a maximum of 20 watts

Magnum 1008 Workgroup Hub

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

concern for AC power-related problems or damage to the unit.

3.2 Powering the Magnum 1000 Workgroup Hub

Hubs, and for connecting the various Ethernet media.

3.1 Table-Top or Rack-Mount

3.0 INSTALLATION

United states and Canada.

model 1008, order part #

brackets easily attach to

the hub, which is then

1016 and 1024. For

1008-RMB.) The

bracket. (This is

cable.

Show 5 more labels / short text on this page
Rack mounting · Rack-mount Brackets · installation requires a · included with models · special rack-mount
Page 29 of the GarrettCom Ethernet Switch (1024) user manual — 2.3Internal Connections, basic AUI Port and Port Modules
Page 29 · click to enlarge
Page 29
3. When proper connection and power have been established, the port’s LINK LED will illuminate GREEN.

The Magnum 1000 workgroup Hub may be used as a stand-alone hub serving

the needs of a small to medium size workgroup or may be connected to a larger network

within a larger network system, the rear port(s) may be connected into a larger network,

Fiber (mm1) FOIRL ST RPM-FST, RPM-SMF, BPM-FST

Fiber (mm1) 10BASE-FL ST or SC RPM-FST, RPM-SMF, BPM-FST

Instructions for connecting the Magnum 1000 Workgroup Hub to each of the

In applications where Magnum hubs are used to provide workgroup services

The following procedure describes how to connect a 10BASE-T twisted pair

segment to the RJ-45 port on the front panel of the hub or to the RPM-TP or BPM-TP.

1. Using standard 10BASE-T media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector. Note that, even though the TP connector is shielded,

environment. In either case, user connectivity is achieved using twisted pair wiring,

Cat. 3 or Cat 5, UTP or STP. There may be some cases where a user device will be

The procedure is the same for both unshielded and shielded twisted pair segments.

The various media types supported and their corresponding IEEE 802.3

ThinNet 10BASE2 BNC RPM-BNC, BPM-BNC

ThickNet 10BASE5 AUI (female) RPM-AUI, BPM-AUI

Twisted Pair 10BASE-T RJ-45 RPM-TP, BPM-TP

either unshielded or shielded 10BASE-T cables and wiring may be used.

3.3.1 Connecting Twisted Pair (RJ-45, Unshielded or Shielded)

2. Connect the other end of the cable to the corresponding device.

Drop Cable 10BASE5 DTE (male) RPM-DTE

Fiber (sgl.m2) * ST RPM-SMF

Media IEEE Standard Connector PM type

1 mm = multi-mode 2 sgl.m = single-mode * 10 Mb operation not currently standardized by IEEE

standards and connector types are as follows:

rather than being used to connect to a user.

3.3 Ethernet Media Connections

standard Ethernet types are given below.

connected via the AUI or Bonus Port.

Page 30 of the GarrettCom Ethernet Switch (1024) user manual — 2.3Internal Connections, basic AUI Port and Port Modules
Page 30 · click to enlarge
Page 30

for normal twisted pair cable segments from the hub port to a user device. Set

1000 directly to a backbone transceiver, the maximum AUI segment length of 50m (165 ft.) is allowed. If the Magnum 1000 is connected to a transceiver that has been cascaded

from another transceiver, the maximum AUI segment length is reduced as stated below.

(20 ft.) for every additional level of network transceiver device "dropped" or "cascaded"

Set the slide switch to the “left” (for port 1) or “down” (for PM-TP) position

network. Verify proper switch position by noting that the port’s LINK LED

Using the steps below as a guide, attach a new or existing 10BASE5 ThickNet

drop-cable directly to the AUI connector on the rear of the Magnum 1000 Workgroup

cascaded or up-link segment connections to another repeater or hub in the

1. Plug the male end of the cable into the female AUI connector on the Magnum 1000 or PM-AUI card. 2. Engage the AUI connector slide lock to insure maximum connectivity. 3. Connect the opposite end of the cable into a network AUI port. (This could be a network backbone transceiver, a hub or fan-out with an AUI

The AUI port may also used for connecting to other Ethernet devices using

According to Ethernet standards, when an AUI cable is used to connect the Magnum

repeater-to-repeater connections without special cross-over connectors.

standard AUI cabling. In this type of situation, it is important to consider the AUI

equipped with an AUI connector and the AUI port of the Magnum 1000 will vary.

BPM-TP) are equipped with a cross-over slide switch to accommodate

the slide switch to the “right” (port 1) or “up” (for PM-TP) position for

The maximum transmission distance between a backbone transceiver

The RPM-AUI connector supports standard IEEE signals, which are

segment length to the attached device, including any cascading.

will illuminate when proper link is established.

port, or an AUI Port Module in a concentrator.)

3.3.2 Connecting ThickNet 10BASE5 (AUI)

Hub or on the RPM-AUI or BPM-AUI port.

from the original backbone transceiver tap.

summarized in Table 3.3.2.

Page 31 of the GarrettCom Ethernet Switch (1024) user manual — 2.3Internal Connections, basic AUI Port and Port Modules
Page 31 · click to enlarge
Page 31

connection. The PM-BNC port is specially equipped with an internal termination switch

on the front of the card (see Section 4.1 for a description of this switch). This eliminates

between FOIRL and 10BASE-FL for users is the maximum distance allowed. 10BASE-

the need to use a "tee" connector when the BNC cable is ending at the connection to this

Using the steps below as a guide, attach the 10BASE5 drop-cable directly to the

1. Plug the female end of the cable into the male DTE connector on the RPM-DTE card.
3. Connect the opposite end of the cable into a network AUI port. (This could be a server, router, bridge, hub, or UNIX workstation.)

3.3.5 Connecting Fiber Optic 10BASE-FL and FOIRL (ST-type, “Twist-Lock")

1. Before connecting the fiber optic cable, remove the protective dust caps from the

Connect the ThinNet coax cable to the BNC connector on the Magnum RPM-

The following procedure applies to FOIRL and 10BASE-FL applications using

an RPM-ST or BPM-ST card with ST-type fiber connectors. (The primary difference

FL is used for a fiber segment length of up to 2000m, while FOIRL is used for fiber

2 Control In Circuit A 11 Data Out Circuit Shield

6 Voltage Common 15 Control Out Circuit B

PM. Some applications may require a "tee" connector, used as a tap, to allow the

1 Control In Circuit Shield 10 Data Out Circuit B

3 Data Out Circuit A 12 Data In Circuit B

7 Control Out Circuit A SHELL Protective Ground

BNC or BPM-BNC card in the same manner as is done for any standard BNC

2. Engage the AUI connector slide lock (on the cable) to insure maximum connectivity.

4 Data In Circuit Shield 13 Voltage Plus (+)

5 Data In Circuit A 14 Voltage Shield

Pin Function Pin Function

2. Pins 4, 8, 11 and 14 may be connected to pin #1.

10BASE2 coax segment to continue on past the PM-BNC connection.

8 Control Out Circuit Shield (conductive shell)

Table 3.3.2AUI Pin Assignments

twisted pair in the AUI cable.

3.3.3 Connecting ThinNet 10BASE2 (BNC)

3.3.4 Connecting Drop Cable 10BASE5 (DTE)

9 Control In Circuit B

DTE connector on the RPM-DTE port.

segments of up to 1000m in length.)

Page 32 of the GarrettCom Ethernet Switch (1024) user manual — 2.3Internal Connections, basic AUI Port and Port Modules
Page 32 · click to enlarge
Page 32

tissue dampened in alcohol. Make certain the connectors are clean before connecting.

3. Connect the Transmit (TX) port (light colored post) on the Magnum PM-FST to

the Receive (RX) port of the remote device. Begin with the color-coded strand

single-mode fiber allows full bandwidth at longer distances, and may be used to connect

The same five-step procedure for multi-mode fiber ST-type applies to single-

Transmit (TX) port of the remote device. Use the non-color coded fiber strand

cable polarity. Swap the fiber cables at the Port Module connector to remedy

wrench) to tighten the fiber optic connectors as this might cause damage and result in

operating problems. Improper and excessive tightening may impair data transmission.

When using the RPM-SMF, be sure to use single-mode fiber cable. Single-

microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are

the diameters of the core and the core plus the cladding respectively). Because of this,

domain and / or power budget limitations may apply for distances over 5Km. Check

connection has been established at both ends (and when power is ON in the

unit). If LINK is not lit after cable connection, the normal cause is improper

When connecting fiber media to SMA connectors, do not over-tighten but

rather simply "finger tighten" these connections. Do not use a heavy tool (such as a

nodes up to 10 Km apart. For operation with standard half-duplex Ethernet, collision

your single-mode configuration with an experienced network designer when you use

2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens
5. The LINK LED on the front of the PM-FST will illuminate when a proper

The same five-step procedure as for fiber ST-type applies to FOIRL and

4. Connect the Receive (RX) port (dark colored post) on the PM-FST to the

mode fiber cable has a smaller diameter than multi-mode Fiber cable (2/15 - 8/60

at regular intervals; you must use the color-coded strand on the

10BASE-FL applications using an RPM-SMA card used with SMA-type fiber

connectors. Follow the five steps as described in the Section 3.3.5 above.

mode fiber connectors. Follow the five steps listed in Section 3.3.5 above.

associated ports at each end of the fiber optic segment.

3.3.6 Connecting Fiber Optic (SMA-type, "Screw-on")*

3.3.7 Connecting Single-Mode Fiber Optic (SMF)

of the cable for this first TX-to-RX connection.

* The RPM-SMA is only available via special order.

this situation.

extended distances.

for this.

Page 33 of the GarrettCom Ethernet Switch (1024) user manual — GARRETT
Page 33 · click to enlarge
Page 33
GarrettCom Ethernet Switch (1024) — 2.3Internal Connections, basic AUI Port and Port Modules diagram (page 33)
Fig. 13 · 2.3Internal Connections, basic AUI Port and Port Mod…

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only

mode 10 (5) 1300 9/125 -30 -39 7 14 13 26

  • The worst-case OPB of the fiber link must be greater than the fiber cable’s

3.3.8 Power Budget Calculations for Magnum 1000 Series RPM’s with Fiber

Receiver Sensitivity and Transmitter Power are the parameters necessary to

  • The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the

full-duplex (factory default) setting for 100Mbps fiber ports must be used,

(1.75”) high. When properly installed, the front-mounted LED status indicators should

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

compute the power budget. To calculate the power budget of different fiber media

where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,

The following data has been collected from component manufacturer’s (HP’s and

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

Siemens’) web sites and catalogs to provide guidance to network designers and

installations using Magnum products, the following equations should be used:

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

OPB (Optical Power Budget) = PT(min) - PR(min)

if the following factors are both applied:

GARRETT

Installation of a Magnum

1000 Series Hub in a 19” rack is a

simple procedure. The units are 1U

passive Attenuation.

3.3.9 Rack-mounting

installers.

Show 4 more labels / short text on this page
Magnum 3000 · Stackable Hub · and · Media
Page 34 of the GarrettCom Ethernet Switch (1024) user manual — 4.0 OPERATION
Page 34 · click to enlarge
Page 34
GarrettCom Ethernet Switch (1024) — 2.3Internal Connections, basic AUI Port and Port Modules diagram (page 34)
Fig. 14 · 2.3Internal Connections, basic AUI Port and Port Mod…

mounted brackets and screws (included with each 1000 series unit). The brackets attach

repeaters. They are compliant with IEEE 802.3 specifications for CSMA/CD 10 Mbps

operation, and support standard IEEE defined media inclusive of 10BASE-T, 10BASE-

FL, FOIRL, 10BASE2, and 10BASE5. The following describes the basic functionality.

The 23” brackets and ETSI brackets are also available (optional) for Rack-

controller functions of the Magnum 1000 Hub’s base unit, functioning together as a

Repeater FunctionalityEach hub port operates in conjunction with the

be in plain view and easy to read. Rack-mount installation requires special rack-

The Magnum 1000 Workgroup Hubs operate as full-function Ethernet

to the front sides of the Hub, which is then fastened into a standard 19” rack.

Workgroup Hub 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Workgroup Hub 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Workgroup Hub 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Workgroup Hub 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

mounting purpose with Magnum 1000 Series Hubs. The 23”

with the necessary screws for the convenient to the customer.

4.1 Magnum 1000 Repeater Functionality

fully compliant Ethernet repeater.

Rack-mounting purpose. The

23” brackets are mainly being used for Huge rack-mounting

frame to provide more secure

and stability to the unit in the

are moreover looks similar to

brackets are more popular in

brackets and mostly used in

the ETSI standard industry.

consider as a standard for

The optional 23” brackets

come in a package along

4.0 OPERATION

and the ETSI brackets

TELCO industry.

Show 4 more labels / short text on this page
(European standard) brackets · TELCO Industry and · The ETSI · the 23”
Page 35 of the GarrettCom Ethernet Switch (1024) user manual — 2.3Internal Connections, basic AUI Port and Port Modules
Page 35 · click to enlarge
Page 35
CollisionsWhen carrier is detected simultaneously on multiple ports, a jam

pattern is generated on each port to create a collision condition. When a collision signal

partition any port where 32 consecutive collisions occur or after 6.5 milliseconds (msec)

of continuous transmissions. Network integrity is checked every 800 msec and segment

Preamble RegenerationMagnum 1000 Hubs will add bits to the preamble

panel LEDs to allow for quick visual assessment of the operational condition of the hub

ACT LEDIlluminates GREEN to indicate “activity”, i.e., that the hub

is processing network packets. Normally flashes to indicate data traffic.

Partitioning and Re-ConnectionMagnum 1000 Hubs will automatically
Fragment ExtensionMagnum 1000 Hubs will automatically add bits to a
Status LEDsEach Magnum 1000 Workgroup Hub is designed with front

and the network. Each Magnum 1000 Hub is equipped with PWR, ACT, and LINK

PWR LEDIlluminates GREEN to indicate proper operation of the

between the hub and the attached device. Each RJ-45 port is represented

received data packet of less than 96 bits (a "fragment") so that the minimum output

operation. LINK is OFF if connectivity or power is lost anywhere along

LEDs. Bonus Port RPMs are also equipped with status LEDs (see Section 2.4).

LINK LEDsIlluminates GREEN when connectivity is established

re-connection occurs after one 512-bit packet is transmitted without an error.

by its own LINK LED. LINK should always be on during normal

from one port is detected, it generates a jam pattern to the other ports.

so that the output packet contains a minimum of a 64-bit preamble.

packet to the other port is 96 bits long.

internal power supply.

the segment.

Page 36 of the GarrettCom Ethernet Switch (1024) user manual — FWD-I LED “ON”
Page 36 · click to enlarge
Page 36

to the external segment. Figure 4.2a: Internal

module which filters and forwards packets at full Ethernet wire speed. These

attached devices are bridge-isolated from the network segment connected through the

NOT IN the address

FWD-X LED “ON”

The filter/forward Figure 4.2bInternal Packet Filtered

micro-bridges are self learning and have small (256 user) address tables.

When configured with a BPM, a Magnum 1000 Workgroup Hub and its

Packet filter/forward decisions are made based on whether the

FWD-I LED “ON”

1. Bridge Functions: Each BPM card contains a compact local bridge

packet source is internal (originates within the local Magnum 1000) or

BPM. The bridge functionality of the BPM bridge modules is described here.

GarrettCom Ethernet Switch (1024) — FWD-I LED “ON” diagram (page 36)
Fig. 15

table.

4.2 Magnum 1000’s with BPM Local Bridge Functionality

table.

external (originates from upstream

forwarded to the outside only if the

an internal packet being forwarded

on the attached segment). If the

address table. Figure 4.2a shows

cases where an internal packet is

source is external, it is forwarded

packet’s source is internal, it is

destination address is not in the

Figure 4.2b show the

are shown in figures 4.2c and

filtered. When the packet’s

destination address is in the

handling of external packets

4.2d respectively. When an

address is not already in the

address table, it is written

to the inside only if the

address table.

Show 13 more labels / short text on this page
are forwarded when · Internal packets · the destination is · are forwarded when · External packets · the destination is · IN the address · Internal packets · are filtered when · the destination is · IN the address · internal packet’s source · Packet Forwarded
Page 37 of the GarrettCom Ethernet Switch (1024) user manual — 2.3Internal Connections, basic AUI Port and Port Modules
Page 37 · click to enlarge
Page 37

there. This happens when a node first sends Figure 4.2c: External Packet

is in the address table, it is purged. Figure 4.2d: External Packet Filtered

Packet Source Destination Address Table Filter/Forward

servers may have heavy local traffic, but only a small amount of traffic that is

2. Throughput Increase: By using a BPM to isolate a user group segment

throughput. For example, a segment containing a group of workstations and

having significant local traffic, it is possible to increase overall network

This can occur if a node has physically moved to a different location.

A summary of the filtering, forwarding, and address table

Source Address Address Maintenance Action

Internal Not in table Not in table Add source to table Forward

Internal In table Not in table Nothing Forward

External Not in table In table Nothing Forward

External In table In table Purge source from table Forward

Internal Not in table In table Add source to table Filter

Internal In table In table Nothing Filter

External Not in table Not in table Nothing Filter

External In table Not in table Purge source from table Filter

address table.

maintenance performed by the BPMs is shown in Table 4.2.

the table become full, the BPM will clear all

under the 256 table addresses size. Should

those connected via the inside of the local

entries in the table by reinitializing itself.

Table 4.2BPM Functionality

table learns only internal addresses, i.e.,

Magnum 1000, a number typically well

a packet upon bridge initialization.

an external packet’s source address

Show 6 more labels / short text on this page
External packets · are filtered when · the destination is · NOT IN the · Forwarded · When
Page 38 of the GarrettCom Ethernet Switch (1024) user manual — 2.3Internal Connections, basic AUI Port and Port Modules
Page 38 · click to enlarge
Page 38

up before bridging services are available. During this time, the BPM performs

Magnum 1000 Hubs are designed with internal auto-ranging AC power supply

isolated from the rest of the network, thus increasing the effective bandwidth

indicate link integrity with an LED. This LINK LED is normally lit. An unlit

segment. All BPMs have FWD-I and FWD-X status LEDs. The FWD-I LED

flashes when packets are forwarded into the local segment. The FWD-X LED

5. Self-test Diagnostics: A Magnum BPM requires 15 seconds upon power-

power needed. See Section 1.1, “Technical Specifications: Power Supply (Internal)” for

directed outside the segment. A BPM connecting this segment to the rest of

Figure 4.2eLocal Segment Isolation with a Bridge Port Module (BPM)
3. Bridge Transparency: The BPMs are transparent to both the users and

units for efficiency and for simplicity of installation and operation. See Section 3.2,

the network, as shown in Figure 4.2e, will keep the local segment traffic

LINK LED indicates a broken cable or loss of power at some point in the

“Powering the Magnum 1000 Workgroup Hub” for detailed information on the AC

4. LINK and Traffic Status: The Magnum BPM-TP and BPM-FST

For optional 48VDC internal power supply information, see Appendix B.

flashes when packets are forwarded out of the local segment.

on both the local segment and the rest of the network.

Local nodes with heavy local traffic,

through Bonus Port configured

connected to front RJ-45 ports

Magnum 1024 Workgroup Hub

with BPM (BPM-FST shown)

detailed information on the internal power supply units.

the application software.

4.3 Power Requirements

an internal self-test.

Local segment isolation

Page 39 of the GarrettCom Ethernet Switch (1024) user manual — 5.0 TROUBLESHOOTING
Page 39 · click to enlarge
Page 39

consistently high performance in all network environments. The installation of Magnum

intended to help locate, identify and correct these types of problems. Please follow the

of the procedures described in this section or if the Magnum 1000 series workgroup hub

1. If difficulty is encountered when installing or operating the unit, refer back to

the Installation Section of the applicable chapter of this manual. Also check

3. Make sure that an AC power cord is properly attached to each Magnum 1000

into a functioning electrical outlet. Use the PWR LEDs to verify each unit is

1000 series workgroup hub and its associated cables are functioning properly.

5. If the problem continues after completing Step 4 above, contact your supplier

suggestions listed below prior to contacting your supplier. However, if you are unsure

series workgroup hub product, it is recommended that the problem device is

corrected. If not, go to Step 5 below. If the problem is corrected, Magnum

is not performing as expected, do not attempt to repair the unit; instead contact your

to make sure that the various components of the network are interoperable.

series workgroup hub unit. Be certain that each AC power cord is plugged

4. If the problem is isolated to a network device other than the Magnum 1000

replaced with a known good device. Verify whether or not the problem is

1000 series workgroup hub is a straightforward procedure (see INSTALLATION,

Should problems develop during installation or operation, this section is

2. Check the cables and connectors to ensure that they have been properly

connected and the cables/wires have not been crimped or in some way

impaired during installation. (About 90% of network downtime can be

of the Magnum 1000 series workgroup hub unit or if unknown, contact

GarrettCom, Inc.by fax, phone or email (support@garrettcom.com) for

All Magnum Ethernet products are designed to provide reliability and

Section 2.6); the operation is also straightforward and is discussed in Section 4.

supplier for assistance or contact GarrettCom Customer Support.

attributed to wiring and connector problems.)

5.1 Before Calling for Assistance

5.0 TROUBLESHOOTING

receiving power.

assistance.

Page 40 of the GarrettCom Ethernet Switch (1024) user manual — 2.3Internal Connections, basic AUI Port and Port Modules
Page 40 · click to enlarge
Page 40

d. Any particular application that, when used, appears to create the problem;

3. It is useful to include other network equipment models and related hardware,

including personal computers, workstations, terminals and printers; plus, the

4. A record of changes that have been made to your network configuration prior

number(s). Include the date(s) that you purchased the products from your

Customer Service at (510) 438-9071 during business hours in California or email to

to the occurrence of the problem. Any changes to system administration

1. A complete description of the problem, including the following points:

support@garrettcom.com). When calling, please have the following information

2. An accurate list of GarrettCom product model(s)involved, with serial

Authorization (RMA) number. To obtain an RMA number, call GarrettCom

All returns for repair must be accompanied by a Return Material

Failure symptoms, including a full description of the problem.

Please be prepared to provide the following information.

5.3 Return Material Authorization (RMA) Procedure

Name and phone number of your contact person.

Packing List Number (or Sales Order Number)

c. The components involved in the problem;

procedures should all be noted in this record.

a. The nature and duration of the problem;

various network media types being used.

b. Situations when the problem occurs;

Name of your company / institution

Serial Number (or Invoice Number)

5.2 When Calling for Assistance

supplier.

readily available:

Your shipping address · Date of installation · Product name

Page 41 of the GarrettCom Ethernet Switch (1024) user manual — APPENDIX A: WARRANTY INFORMATION
Page 41 · click to enlarge
Page 41
1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic

material. This material may cause electro-static shock damage to the unit.

sheet or bag for shipping protection. ( You may retain all connectors and

CAUTION : Do not pack the unit in Styrofoam "popcorn" type packing

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

units under warranty. Testing and repair of product that is not under warranty will

Should you need to ship the unit back to GarrettCom, please follow these

replace components in the products that prove to be defective at no charge other

product has been damaged by misuse, misapplication, or as a result of service or

repair products that are under warranty at no charge, and will return the warranty-

condition causing the return cannot be duplicated by GarrettCom, the unit will be

GarrettCom reserves the right to charge for the testing of non-defective

This warranty will not be effective if, in the opinion of GarrettCom, the

Please complete the warranty card as this acts as a product registration,

GarrettCom will carefully test and evaluate all returned products, will

than shipping and handling, provided that the product is returned pre-paid to

inspecting any product returned for warranty repair which turns out not to be

materials and workmanship for a period of three (3) years from the date of

During this warranty period, GarrettCom will repair or, at its option,

Information, Appendix A, for complete details). However, if the problem or

3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to:

GarrettCom, Inc. warrants its products to be free from defects in

GarrettCom reserves the right to make a charge for handling and

repaired units to the sender with shipping charges prepaid (see Warranty

and mail it to GarrettCom within two weeks of your purchase.

APPENDIX A: WARRANTY INFORMATION

No Problem Found.

5.4 Shipping and Packaging Information

Attn.: Customer Service

modification other than by GarrettCom.

213 Hammond Ave.

this Installation Guide.)

GarrettCom, Inc.

result in a customer (user) charge.

shipment by GarrettCom.

GarrettCom.

returned as:

instructions:

faulty.

Fremont, CA 94539

Page 42 of the GarrettCom Ethernet Switch (1024) user manual — OPERATION
Page 42 · click to enlarge
Page 42

inside on each DC power input line behind the two external power connection terminals,

With the exception of the power supply, all specifications and functions of

Magnum 1000 Workgroup Hubs-48VDC, 24VDC & 125VDC models are identical

example, will neither effect the hub, nor its power supply internally, nor will it blow the

Disconnecting the power source is used for powering the hub on and off when

Power ConsumptionMagnum 1000’s Hubs: 10 watts typical,

20 watts max. P.S. rating

GND GND CHASSIS

B1.0 SPECIFICATIONS - FOR MAGNUM 1000 WORKGROUP HUBS

The -48VDC, 24VDC & 125VDC power option is designed using diodes

SUPPLY

FUSE +

the hub from incorrect DC input connections. An incorrect polarity connection, for

HUB

Power ConsumptionMagnum 1000’s Hubs: 10 watts typical,
Power ConsumptionMagnum 1000’s Hubs: 10 watts typical,

B2.0 -48VDC, 24VDC & 125VDC POWER OPTION, THEORY OF

20 watts max. P.S. rating

20 watts max. P.S. rating

APPENDIX BInternal DC Power Supply Option

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

Input Voltage120 - 160 VDC (auto-ranging)
Input Voltage36 - 70 VDC (auto-ranging)
Input Voltage20 - 40 VDC (auto-ranging)

A+

A-

Power Supply (Internal -48 VDC Option)

Power Supply (Internal 125 VDC Option)

Power Supply (Internal 24 VDC Option)

source can only flow into the hub. This

it is placed into or taken out of service.

to those listed in the main manual.

applied to the two inputs. It protects

so that the power from an external

fuse in the internal power supply.

whenever DC power is correctly

allows the hub to operate only

OPERATION

Page 43 of the GarrettCom Ethernet Switch (1024) user manual — B3.0 APPLICATIONS
Page 43 · click to enlarge
Page 43

The solution is particularly useful in the telecommunication industry, where it

monitoring equipment. In addition, many high-availability equipment services, such as

Industrial environment, where it is common facilities to operate on 24VDC & 125VDC

substation, Electrical generating plant etc. Whereas 24VDC application is mainly in the

terminals, positive (+) and negative (-) screws. The use of Ground (GND) is optional; it

applications where -48VDC, 24VDC & 125VDC power is used as the primary power

is common for facilities to operate on -48VDC power. Such companies include regular

communication companies, and firms supplying network management and operations

are identified as negative (-), positive (+), and chassis ground (GND). The connection

source. The -48VDC, 24VDC & 125VDC power configuration provides an Ethernet

in broadcasters, publishers, heavy industrial plants, brokerage firms and others, often

This section describes the installation of the -48VDC, 24VDC &125VDC

power source leads to the -48VDC, 24VDC & 125VDC power terminal block on the

networking solution utilizing a special DC internal power supply in hubs having a

use a battery backup system to maintain operations in the event of a power failure.

The 24VDC & 125VDC solution are particularly useful in the

power. The 125VDC solution is mainly used in Utilities Industries, such as Electric

Industrial environment, such as chemical plants, paper mill, stone quarrying plant,

and wireless telephone service providers, Internet Service Providers (ISPs), other

procedure is straightforward. Simply connect the DC leads to the Switch’s power

Magnum 1000 Workgroup Hubs are easily installed in a variety of

connects to the Switch chassis. Ensure that each lead is securely tightened.

_ + GND

36-70VDC

Block on Magnum 1000’s-48VDC

125VDC terminal block on the Magnum 1000’s is located on the rear

of the unit and is equipped with three

(3) screw-down lead posts. The leads

Magnum 1000’s. (see figure below).

Figure B4.1-48VDC Terminal

The -48VDC, 24VDC &

wastewater treatment Plant etc

B3.0 APPLICATIONS

B4.0 INSTALLATION

proven reliability record.

Page 44 of the GarrettCom Ethernet Switch (1024) user manual — B5.0 OPERATION
Page 44 · click to enlarge
Page 44
1. Minimum 14 AWG cable for connection to a Centralized DC power source. 2. Fastening torque of the lugs on the terminal block: 9 inch pound max. 3. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located

To order the optional -48VDC power supply factory installed, add a suffix of

always use a digital voltmeter to measure the output voltage of the power supply and

terminal lead from 48V or –48V Power supply must be connected to the post labeled

“-48VDC” after the product’s standard model #. Example: Magnum 1016-48VDC.

Disconnecting the DC power source is used to remove the unit from service, and as a

determine the lead which is more “+ve potential Lead”. The more “+ve” voltage

Operation of the Magnum 1000’s with the optional -48VDC, 24VDC &

125VDC power supply is identical to that of the standard AC-powered models.

Please refer to Section 6.0 for troubleshooting

power-down to RESET the hub’s electronics if needed.

Similarly for “24VDC”: Magnum 1016-24VDC.

within 6 inches of the terminal block.

B6.0 ORDERING INFORMATION

The GND can be hooked at the last.

B7.0 TROUBLESHOOTING

B4.1 UL Requirements

B5.0 OPERATION

“+”.

Ask about the GarrettCom Ethernet Switch (1024)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom Ethernet Switch (1024)

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom Ethernet Switch (1024) manual PDF

44 pages·604 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…