EN
GarrettCom logo
Official user manual

GarrettCom P80F

28 pages·198 KB·Switch·PDF·ENDEFRITNLJA
GarrettCom P80F
Table of Contents 44 sections Magnum P80F & P80C · Personal Switches · Installation and User Guide · Magnum ™ P80F & P80C Personal Switches · … ShowHide
Page 1 of the GarrettCom P80F user manual — Magnum P80F & P80C
Page 1 · click to enlarge
Page 1
GarrettCom P80F — Magnum P80F & P80C diagram (page 1)
Fig. 1 · Magnum P80F & P80C

Magnum P80F & P80C

Personal Switches

Installation and User Guide

GarrettCom P80F — Magnum P80F & P80C diagram (page 1)
Fig. 2 · Magnum P80F & P80C
Page 2 of the GarrettCom P80F user manual — Installation and User Guide
Page 2 · click to enlarge
Page 2

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

serviceable parts. Attempted service by unauthorized personnel shall render all

P80C Personal Switch products, consult Section 5, Troubleshooting, of this User

GarrettCom, Magnum and Personal Switch are trademarks and Personal Switch is a

warranties null and void. If problems are experienced with Magnum P80F &

Magnum ™ P80F & P80C Personal Switches

of this publication may be reproduced without prior written permission from

Installation and User Guide

Copyright © 2001 GarrettCom, Inc. All rights reserved. No part

Part #84-00079, (Rev B 4/01)

UL is a registered trademark of Underwriters Laboratories

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

registered trademark of GarrettCom, Inc.

Printed in the United States of America.

Guide.

GarrettCom, Inc.

Trademarks

Page 3 of the GarrettCom P80F user manual — Phone (510) 438-9071
Page 3 · click to enlarge
Page 3

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

This equipment generates, uses and can radiate frequency energy and if not

installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested and found

to comply with the limits for a Class A computing device in accordance with the

specifications in Subpart J of Part 15 of FCC rules, which are designed to provide

reasonable protection against such interference when operated in a commercial

environment. Operation of this equipment in a residential area is likely to cause

interference, in which case the user at his own expense will be required to take whatever

Please use the mailing address, phone and fax numbers and email address listed below:

Radio Frequency Interference Statement

Websitehttp://www.GarrettCom.com

email support@garrettcom.com

47823 Westinghouse Dr. Fremont, CA 94539

GarrettCom, Inc.

Phone (510) 438-9071

measures may be required to correct the interference.

Federal Communications Commission · Fax (510) 438-9072 · Contacting GarrettCom, Inc

Page 4 of the GarrettCom P80F user manual — Fan-Outs, 10Mb series
Page 4 · click to enlarge
Page 4

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

2, 4 and 8 Port Models Transceivers, 10Mb and 100Mb series 10Mb Mini-Transceivers and

GarrettCom, Inc.offers the premium-quality Magnum™ line of Ethernet LAN

connectivity products with industry-standard functionality and built-in fiber

configurability. Magnum products are designed for use in demanding Carrier Class,

Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports,

4K-Series Switches, 100 & 10Mbps, copper ports with optional fiber port, with auto-negotiating full switching performance

8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series

Industrial Grade and OEM applications where reliability is a primary consideration.

“Outdoor” Ethernet Switch, for temperature uncontrolled locations

6 10/100 and 2 100Mb fiber ports, can be connected in strings Mixed-Media Fiber Hub, 16-port Stackable, 10/100 auto-sensing

10Mb series and 100Mb series, both w/ optional port modules Personal Switches, 10/100Mb

All media combinations, incl. fiber ST, SC, mm., single mode

Bridge Port Modules (BPMs), 4 types, for segment isolation

Repeater Port Modules (RPMs), 6 types for Ethernet media

Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing

Stackable Concentrators, SNMP optional, 13-Ports

mixed-speed and mixed-media types, full switching performance

8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb

The “X-line” of configurable Mi X ed Media products:

ETHERNET CONNECTIVITY PRODUCTS

Mini-Concentrators, 7 Ports, Repeaters, 2-Ports

"DESIGNED AND MANUFACTURED IN THE USA"

8-port, with two switched ports (1 fiber built in) Personal Hubs, 10Mb series

The Magnum Line

OVERVIEW

Stackable Hubs, SNMP Optional

Coax Models, All Types - Apr, 01

Fan-Outs, 10Mb series

Page 5 of the GarrettCom P80F user manual — The “X-line” of configurable Mi X ed Media products:
Page 5 · click to enlarge
Page 5
Page 5 of the GarrettCom P80F user manual — The “X-line” of configurable Mi X ed Media products:
Page 6 of the GarrettCom P80F user manual — 1.0 SPECIFICATIONS
Page 6 · click to enlarge
Page 6

Filtering and Forwarding Rate from 100Mbps ports: 148,800 pps max

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.

Input: 95-125 vac at 60Hz for “-d” Models 200-250 vac at 50Hz for “-i” Models, which have IEC power cable connector in the external power unit.

Auto-learning16K address table, shared for all traffic domains

100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3u

Latency (not including packet time): 100 to 10 Mbps: 5µs 10 to 100Mbps: 5µs Path Delay Value: 50 BT on all ports

100BASE-FX, full-duplex(single-mode, long) - 40.0 km (131,240 ft)
Packet buffers512KB, dynamically shared on all domains
100BASE-FX, full-duplex(single-mode) - 20.0 km (65,620 ft)

10BASE-T (Unshielded twisted pair) - 100 m (328 ft)

100BASE-TX (CAT 5 UTP) - 100 m (328 ft)

100BASE-FX, full-duplex(multi-mode) - 2.0 km (6,562 ft)
100BASE-FX, half-duplex(multi-mode) - 412 m (1350 ft)
100BASE-FX, half-duplex(single-mode) - 412 m (1350 ft)

Ambient Temperature: 32ºF to 120ºF (0ºC to 50ºC) Storage Temperature: -5ºC to 160ºF (-20ºC to 70ºC)

Ambient Relative Humidity10% to 95% (non-condensing)

Power Consumption: 8 watts typical, 10 watts max.

Maximum Ethernet Segment (or Domain) Lengths

Output5VDC, 2Amps Polarity: center positive, shell negative

When a port is operating at 100Mbps:

When a port is operating at 10 Mbps:

Data Rate10 Mbps

Packet-Processing Between Domains

Processing typeStore and Forward
Data Rate100Mbps

Power Supply (External )

1.1 Technical Specifications

1.0 SPECIFICATIONS

Operating Environment · Ports Performance · Network Standards

Page 7 of the GarrettCom P80F user manual — Packet-Processing Between Domains
Page 7 · click to enlarge
Page 7

Network Cable Connectors - for eight RJ-45 shielded female ports and 1 fiber port

10 MbpsCategory 3, 4, 5 UTP (Note: auto-sensing does not sense cable type)

connection to a central switch or to another P80F, P80C (or equal) unit. The up-

works the same at 10 Mbps or 100Mbps speed and at full- or half-duplex mode.

Full- or Half-Duplex selection on switched Ports # 2 or 2SW for Magnum P80F

Manual switch selects fiber port for FDX or HDX. See Section 4.3 for details.

Port # 1 (switched RJ-45) has a manual crossover (MDIX up-link) switch for

link port # 1 is auto-sensing for speed, and its auto-negotiating up-link feature

WarrantyThree years, return to factory Made in USA

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

Manual switch selects port #2 for “FF” or “A”. See Section 4.3 for details.

Dimensions: 1.25 in H x 6.75 in W x 5.0 in D (3.2 cm x 17.1 cm x 12.7 cm)

100MbpsCategory 5 UTP/STP, fiber (50/125, 62.5/125, 9/125 micron)

Full-Fixed or Auto-negotiation selection on switched Ports # 2 or 2SW for

LINK/ACTSteady On for LINK with no traffic, blinking indicates port
Power Input Voltage36 to 70 VDC (auto ranging), “-, GND, +”
EnclosureRugged high-strength sheet metal. Metal mounting clips

included. Suitable for wiring closet shelf, wall or desktop mounting.

SPEED (with LINK ON)ON = 100Mbps; OFF = 10 Mbps

Power Consumption: 8 watts typical, 10 watts max.

Weight (of power supply unit)1.0 lb. (455 g.)

External -48VDC Power Supply (Optional)

F/HON = full-duplex, OFF = half-duplex
Weight (of Switch unit)1.0 lb. (455 g.)
PWRSteady On when power applied

is transmitting / receiving.

Emissionsmeets FCC Part 15, Class B
ERRORSelf-test at power up failed
Maximum Load per port60 mA

UL Listed (UL 1950), cUL, CE

Cooling methodConvection

Up-Link, Port # 1 or 1SW

Show 4 more labels / short text on this page
Agency Approvals · LED Indicators · Magnum P80 · Packaging
Page 8 of the GarrettCom P80F user manual — copper ports
Page 8 · click to enlarge
Page 8

half- or full-duplex switched RJ-45 10/100 auto-negotiating ports. Includes

store-and-forward switching that filters and forwards data moving between

Magnum P80C-d, or -i8-port 10/100Mb “copper” office switch with eight 10/100

switched fiber port (multi-mode SC-type connector), and seven “N-way”

internal switch has 16K nodes address table and 512KB packet buffers.

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

the ports. The internal switch has 16K nodes address table and 512KB

Magnum P80F-MST-d, or -iSame as P80F but with multi-mode STtype
Magnum P80F-SSCL-d, or -iSame as P80F but with single-mode (Long

switching that filters and forwards data moving between the ports. The

Use “-d” suffix for external power supply at 115vac 60Hz; use “-i” suffix for external at

Magnum P80F-SSC-d, or -iSame as P80F but with single-mode SC-type
Magnum P80F-MTRJ-d, or -iSame as P80F but with multi-mode MTRJ-
Magnum P80F-MSC-d, or -i8-port Personal Switch with one 100Mbps

Magnum P80C, 10/100 Personal Switch with all

N-way auto-negotiating switched ports. Includes store-and-forward

reach, 40Km) SC-type fiber connector.

with a 100Mb Fiber Port

Magnum P80F, 10/100 Personal Switch

GarrettCom reserves the right to change specifications, performance

packet buffers. External power supply.

type fiber connector.

fiber connector.

fiber connector.

characteristics and / or model offerings without notice.

External power supply.

1.2 Ordering Information

copper ports

230vac 50Hz.

Page 9 of the GarrettCom P80F user manual — 2.0 INTRODUCTION
Page 9 · click to enlarge
Page 9

notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect

1 Magnum P80F Personal Switch with a Fiber Port, or Model P80C with all copper

Remove the Magnum P80F or P80C Personal Switch from the shipping container. Be

In the event there are items missing or damaged, contact your supplier. If you need to

switched fiber link upstream, coupled with the convenience of switched 10/100Mb copper ports

10/100 auto-negotiating RJ-45 ports. The P80C “Copper” model has been designed with all eight

the contents of this package for any signs of damage and ensure that the items listed below are

sure to keep the shipping container should you need to ship the unit at a later date. To validate

Magnum P80F “Future-proof Fiber” models have been designed with one full-duplex

Examine the shipping container for obvious damage prior to installing this product;

RJ-45 switched ports with “N-way” x half/full duplex capability and functions as 10/100 auto-

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

the product warranty, please complete and return the enclosed Product Registration Card to

return the unit, use the original shipping container. Refer to Chapter 5, Troubleshooting, for

100Mbps switched fiber port, and seven of “N-way” switched RJ-45 with full / half-duplex

The P80-series Personal Switches provide the performance of a built-in 100Mb

1 External Power Supply, 5VDC from either 115v 60Hz or 230v 50Hz

1 Set of metal clips and screws for secure shelf or wall-mounting

for workplace LAN connections, all in one compact unit.

2.1 Inspecting the Package and Product

1 Installation and User Guide

1 Product Registration Card

2.2 Product Description - General

GarrettCom as soon as possible.

2.0 INTRODUCTION

This package should contain:

specific return procedures.

ports.

included.

Page 10 of the GarrettCom P80F user manual — GARRET
Page 10 · click to enlarge
Page 10

classroom and in network traffic centers, or multi-system power users, the Magnum P80 & P80F

Top-mounted LEDs provide status information on each port. The Magnum P80 & P80F Personal

optional fiber port is normally configured and tested with the Magnum P80F unit in the factory,

P80F Personal Switches, with store-and-forward switching, filter all faulty packets to minimize

external. The front side of the chassis has eight RJ-45 twisted-pair ports and one 100Mbps fiber

The Magnum P80 & P80F Personal Switches provide the switching speed and

The P80 & P80F Personal switches are non-blocking on all ports and include 512KB

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

the reliability to smoothly support multiple workgroups at 100Mbps or 10 Mbps speed. The

Designed for use in departments with multiple workgroups, in remote offices, lab,

Personal Switches are easy to install and use. Addresses of attached nodes are automatically

learned and maintained, adapting the switching services to network changes and expansions.

packet buffers and 16K-node address table for advanced performance. The Magnum P80 &

2.2.1 Magnum P80F chassis with fiber ST or SC (m.m. or single-mode) connector

The Magnum P80F chassis houses one main PC board. The power supply unit is

negotiating ports. For half- or full duplex selection on the P80F, and Full-fixed and Auto-

Switches provide high performance plug-and-play operation in compact packages.

GarrettCom P80F — Personal Switch diagram (page 10)
Fig. 3 · Personal Switch

UPLINK 2 3 4 5 6 7 8 1SW

PORTS 1 2 3 4 5 6 7 8

negotiation selection on the P80, see sections 4.3 and 4.4.

PORTS 1 2 3 4 5 6 7 8

UPLINK 2 3 4 5 6 7 8 1SW

Personal Switch

and available in all popular fiber connectors.

2SW

F/H

F H = X

traffic congestion.

GARRET

F H

Show 9 more labels / short text on this page
Magnum P80 · 5V, 2Amps · Link/Act · Speed · Fiber SC above · Fiber ST above · Power · Error · Tx Rx
Page 11 of the GarrettCom P80F user manual — F/
Page 11 · click to enlarge
Page 11

(PWR) and ERROR (self-test at power up failed) indicators for the unit. For each port, there are

power supply is 5VDC at either 95 - 125vac at 60 Hz for “-d” models or 120-230vac at 50Hz for

LEDs to indicate operating status of all ports are mounted on the top. There are power

(PWR) and ERROR (self-test at power up failed) indicators for the unit. For each port, there are

The unit has an up-link Port # 1 or 1SW, located on the left-front side of the Switch. It

port. Port # 2SW always supports fiber ports only and the RJ-45 connector is inoperative at all

The DC power plug connector or “jack” is in the left rear of the chassis. The external

Link and Activity (LINK/ACT) LEDs indicating traffic, speed (ON for 100Mbps), and full/half

120-230vac at 50Hz for “-i” models that have IEC power cable connector in the external power

(See Section 4.6 for more details about up-link). Port #1SW is capable of full- and half-duplex

times. LEDs to indicate operating status of all ports are mounted on the top. There are power

The DC power plug connector or “jack” is in the left rear of the chassis, like the

P80F. The external 5VDC power supply is for either 95 - 125vac at 60 Hz for “-d” models or

enables the port’s twisted pair cable to cascade to another shared hub or switching hub port.

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

Link and Activity (LINK/ACT) LEDs indicating traffic, and speed (ON for 100Mbps), and

The Magnum P80C chassis houses one main PC board. The power supply unit is

external. The front side of the chassis has eight twisted-pair switched ports. Port 2SW has

operates the same, whether Port # 1SW is connected to either 100Mbps or 10Mbps devices.

“-i” models that have IEC power cable connector in the external power supply housing.

mode auto-sensing, based on the capability of the connected device. The up-link feature

manually-selectable Full-Fixed and Auto-negotiation capability. See section 4.4.

UPLINK 3 4 5 6 7 1SW

PORTS 1 2 3 4 5 6 7

2.2.2 Magnum P80C chassis with all RJ-45 Copper ports

Personal

full/half (F/H) duplex indicators.

5VDC,

duplex (F/H is ON for full duplex) indicators.

2SW

2.3 Up-link Port 1SW for Cascading

F/

FF A =

GARRET

Show 7 more labels / short text on this page
Magnum P80 · Link/Act · Speed · Tx UPLINK · Powe · Erro · supply housing
Page 12 of the GarrettCom P80F user manual — F H = X
Page 12 · click to enlarge
Page 12

100Mb speed for guaranteed high performance. The P80F’s fiber port is factory-built as either a

multi-mode ST, multi-mode SC, multi-mode MTRJ or single-mode or long-reach SC connector.

Ports 2SW (the fiber port) has an “F - H” user-selectable manual switch. When set in

the “F” position, it forces full-duplex mode. When set in the “H” position, it forces half-duplex

On Magnum P80F units, there are three LED’s for the switched ports. One (LK/ACT)

A fiber cable must be connected to the 100Mb port and a proper link (LK lit) must be

The Fast Ethernet fiber switched port on the Magnum P80F is set to operate at fixed

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

When the up-link port is used to cascade two P80-series Personal Switches, the auto-sensing

or SC type (single-mode or multi-mode)

The 100Mb fiber port will run at 100Mbs speed at all times with manually selected full- and

half-duplex capability. The 100Mbps fiber port is a switched port and performs as a domain,

is steady ON to indicate LINK, blinking indicates the port is transmitting and receiving. The

made with the device at the other end of the cable in order for these LEDs to provide valid

feature will cause the connecting link to operate at 100Mbps speed and full-duplex mode.

providing a high bandwidth backbone connection (no media converter is required!) and

SPEED LED is ON for 100Mbps and OFF for 10 Mbps (when LINK is made). The F/H

F H = X

UPLINK F H

supporting long (up to 40km) fiber cable distances for installation versatility.

indicates full-duplex when ON, when it is OFF, operation is half-duplex.

2.4 Fiber port, ST or SC Connector for Model P80F

100Mbps Fiber port, ST-type mm

indications of operating conditions.

F H = X

UPLINK

mode, still at 100Mbps speed.

Tx Rx · Tx Rx

Page 13 of the GarrettCom P80F user manual — UPLINK F H
Page 13 · click to enlarge
Page 13

packets. This eliminates the propagation of bad packets, enabling all of the available bandwidth

segments connected. The "cut-through" technique permits collision fragment frames, which are

a result of late collisions, to be forwarded to add to the network traffic. Since there is no way to

To minimize the possibility of dropping frames on congested ports, each Magnum P80

ensuring that heavily used ports receive very large buffer space for packet storage. (Many other

resources of the Magnum P80 unit to be applied to all traffic loads, even when the traffic activity

is unbalanced across the ports. Since the traffic on an operating network is constantly varying in

industry standard (full-duplex only) PAUSE packets out to the devices sending packets to cause

“flow control”. This tells the sending devices to temporarily stop sending traffic, which allows a

The Magnum P80 & P80F are store-and-forward switches. Each frame (or packet) is

ensures that all forwarded frames are of a valid length and have the correct CRC, i.e., are good

loaded into the Switch’s memory and inspected before forwarding can occur. This technique

heavy, the result of store-and-forward operation is that more bandwidth is available for good

switches have their packet buffer storage space divided evenly across all ports, resulting in a

packet density per port and in aggregate density, the Magnum P80 & P80F Personal Switches

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

calculated), the result of indiscriminate cut-through forwarding is greater traffic congestion,

especially at peak activity. Since collisions and bad packets are more likely when traffic is

& P80F Personal Switches dynamically allocates buffer space from an 1MB memory pool,

small, fixed number of packets to be stored per port. When the port buffer fills up, dropped

are constantly adapting internally to provide maximum network performance with the least

When the Switch detects that its free buffer queue space is low, the Switch sends

While other switching technologies such as "cut-through" or "express" impose

minimal frame latency, they will also permit bad frames to propagate out to the Ethernet

packets result.) This dynamic buffer allocation provides the capability for the maximum

traffic catch-up to occur without dropping packets. Then, normal packet buffering and

filter frames with a bad CRC (the entire frame must be present in order for CRC to be

2.5 Frame Buffering and Latency

packets when the traffic load is greatest.

to be used for valid information.

dropped packets.

Page 14 of the GarrettCom P80F user manual — UPLINK F H
Page 14 · click to enlarge
Page 14

detects that its free buffer queue space is low, the Switch prevents more frames from entering by

The LEDs that indicate operating status are on the top of the unit for easy viewing

collision-based flow-control mechanism (when operating at half-duplex only). When the Switch

types, and the length of the frame is a variable here as it is with all store-and-forward switches.

microseconds plus the packet time at 10 Mb. For 100Mb-to-100Mb forwarding, the latency is 5

forwarded to its destination) of the P80 & P80F Personal Switches varies with the port-speed

Built-in fiber ports may be ordered with 100Mb full-duplex mm ST, SC, MTRJ

and single-mode SC, SSCL-type connectors. The fiber port can be set as full or

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

processing resumes. This flow-control sequence occurs in a small fraction of a second and is

forcing a collision signal on all receiving half-duplex ports in order to stop incoming traffic.

For 10 Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the latency is 15

Magnum P80 & P80F Switches provide Fast Ethernet switching on all ports.

They perform high speed filter/forward operations on the traffic, giving each

half-duplex mode by a manual switch selection. No Media Converter needed.

negotiation to all the ports. All RJ-45 ports are capable of half- or full-duplex.

in any situation. For the difficult near-the-floor mounting locations that are

convenient for keeping the cables out of the way, the LEDs are still easily

Another feature implemented in Magnum P80 & P80F Personal Switches is a

The latency (the time the frame spends in the Switch before it is sent along or

RJ-45 ports provide twisted pair segment connections, with N-way auto-

„ Option for one “future-proof” fiber ports connector, Model P80F

„ 100Mb switching services for high performance Ethernet LANs

port’s segment a full 100Mb (or 10 Mb) of bandwidth.

transparent to an observer. See Section 4.6 for additional details.

„ Model P80C with all RJ-45 (copper) ports

„ Top-mounted LEDs for convenient viewing

microseconds plus the packet time at 100Mb.

2.6 Features and Benefits

viewed.

Page 15 of the GarrettCom P80F user manual — UPLINK F H
Page 15 · click to enlarge
Page 15

The Magnum P80F & P80C operates as a hardware switch, only forwarding those

packets from each domain that are needed on the other domains. Internal address

in offices and labs, or virtually any workspace location within reach of a standard

mount. There is a choice of external power supplies, for either 115vac or 230vac.

high bandwidth backbone for access to a central LAN and central file servers. A Magnum P80F

An up-link switch is built in for port # 1. The F/H 10/100 switched RJ-45 port #

1 can support a local server, a power user, another hub or switch cascaded, or a

The compact packaging of Magnum P80F & P80C’s allows them to be installed

small class or lab with multi-servers and mixed-speed requirements like surfing the Internet or

users and utility devices (such as print servers) run at 10 Mbps. High performance users need a

Personal Switch serves this requirement economically. The eight full-and half duplex switched

The P80F & P80C are designed to bring future-proof fiber connectivity and widely-

ports capability makes the required setup simple. Any attached node can change speed at any

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

tables are self-learning, enabling users to change port connections or 10/100

AC wall outlet. They come in a durable metal enclosure for table-top or wall-

Example 1. Magnum P80F In this example, a Magnum P80F Personal Switch serves a

downloading data from servers or other sources. Some users operate at 100Mbps, and some

„ Installation is “Plug and Play”, operation is transparent to software

switched “stack” connection to another P80F or P80C for expansion.

used copper connectivity to small user groups in offices, classrooms and labs.

„ Up-Link on port # 1 for a high speed “copper” connection

„ Small enclosure enables use in offices, labs and classrooms

time without affecting network operation or impacting other users.

domains without affecting operations.

2.7 Applications

Page 16 of the GarrettCom P80F user manual — UPLINK F H
Page 16 · click to enlarge
Page 16
GarrettCom P80F — UPLINK F H diagram (page 16)
Fig. 4
Figure 2.7.1A P80F connects combinations of 10 Mbps and100Mbps network devices and

The 100Mb fiber port on the P80F can be used for accommodating high performance

functions support a mixed environment of 10 Mbps and 100Mbps users, and the switching full /

Where there is existing 10 Mbps hubs or switches users, they can easily be cascaded

into any port of the P80F. This allows a simple plug-and-play addition of 100Mbps ports to an

The Magnum P80C fits very well in a small business experiencing a need to scale its

half duplex capability on all eight ports provides bandwidth for high performance. The up-link

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

data transfers, and provides fiber connectivity built-in rather than needing an auxiliary media

converter unit. The 100Mbps traffic does not use the bandwidth of the 10 Mbps domain, so

LAN quickly and cost effectively. With its Half / Full duplex switching capability, the P80C

existing 10 Mbps network without having to change it. Nodes that are capable of 100Mbps

provides a very economical high bandwidth solution at each copper port. The Dual-Speed

speed can be moved to a P80F port, and will automatically operate at the higher speed.

provides a Fast Ethernet fiber backbone for access to the central LAN.

overall performance of the network is sustained at the highest possible level.

Example 2. Magnum P80C

UPLINK 2 3 4 5 6 7 8 1SW

PORTS 1 2 3 4 5 6 7 8

on Port 1 enables easy expansion.

10 Mbps · 10 Mbps

Page 17 of the GarrettCom P80F user manual — PORTS 1SW 2SW 3 4 5 6 7 8
Page 17 · click to enlarge
Page 17
GarrettCom P80F — PORTS 1SW 2SW 3 4 5 6 7 8 diagram (page 17)
Fig. 5
Figure 2.7.2Two P80C connects together to provide 10 Mbps and100Mbps network with

operate at 100Mb as well as at 10 Mb, and utility devices (such as print servers) run at 10 Mbps.

In this example, two of the Magnum P80C Personal Switch cascaded together to serve a small

office with multi-servers, print server, internet access and mixed-speed requirements. The users

High performance users need a high bandwidth up-link for access to a central LAN and central

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

file servers. Any attached node can change speed at any time without affecting network

Fast Ethernet backbone.

operation or impacting other users.

PORTS 1SW 2SW 3 4 5 6 7 8

Page 18 of the GarrettCom P80F user manual — F/H
Page 18 · click to enlarge
Page 18

mounting bracket for wall mounting

physical layout of the network. Typically the switch is located in a workplace site. The compact

P80F & P80C site. The rugged metal case of the Magnum P80F & P80C will normally protect it

size of the unit allows it to be conveniently placed in an office, classroom or lab area, and it can

from accidental damage in a lab or workplace setting. Maintain an open view of the top surface

orientation or position. The brackets are attached to the metal Switch case using one of the

The Magnum P80F & P80C Personal switch can be easily mounted on a table-top or

any suitable horizontal surface, and has four rubber feet to provide stability without scratching

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

also be either shelf- of wall-mounted (see mounting instructions in 3.1.2 below). Metal wall-

Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum

The location of a Magnum P80F & P80C Personal Switch is dependent on the

This chapter provides instructions for installing Magnum P80-series units.

Proper attachment of

3.1 Locating Magnum P80F & P80C 10/00Mb Personal Switch

Top view - Magnum P80F with

brackets attached for wall

PORTS 1SW 2SW 3 4 5 6 7

Personal Switch

3.1.2 Wall (or vertical surface) mounting

mounting brackets (and screws) to allow the

Personal Switch is shipped with two metal

unit to be mounted in nearly any desired

mounting clips are included with the unit.

3.1.1 Table-Top or Shelf Mounting

to visually monitor the status LEDs.

F/H

GARRETT

5VDC,

3.0 INSTALLATION

finished surfaces.

Show 6 more labels / short text on this page
Magnum P80 · Each Magnum P80-series · Speed · Link/Act · Power · Error
Page 19 of the GarrettCom P80F user manual — Proper attachment of
Page 19 · click to enlarge
Page 19

surface. It is recommended to use appropriate # 4 screws for attaching mounting bracket to

wall (e.g wood screw, self-tapping screw, machine screw). It is also recommended that the

making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be

100Mbps) be used whenever possible in order to provide flexibility in a mixed-speed network, since P80-series switch ports are auto-sensing for either 10 and 100Mbps.

metal screws for each bracket and attaching to the Magnum P80F and P80C through the

brackets will extend slightly below the base of the unit to allow clearance for the rubber

100BASE-TX and 10BASE-T, however, P80F can be connected to the following three media

used. In either case, the maximum distance for unshielded twisted pair cabling is 100 meters

(328 ft). For fiber port 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling can be

used, whereas for single-mode, 9/125 microns cabling should be used. Fiber cabling supports

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

round hole of the bracket. A user-supplied screw attaches the bracket to the mounting

3.2.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded)

The following procedure describes how to connect a 10BASE-T or 100BASE-TX

brackets be attached to two opposite corners of the unit. When properly attached, the

types100BASE-TX, 10BASE-T and 100BASE-FX. CAT 5 cables should be used when

twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and

The Magnum P80C Personal Switch can be connected to two media types i.e.

Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45

Twisted Pair (CAT 5) 100BASE-TX RJ-45

much longer cable distance and higher bandwidths as compared to copper wiring.

Media IEEE Standard Connector

Fiber (Multi-mode) 100BASE-FX MTRJ

Fiber (Multi-mode) 100BASE-FX ST

Fiber (Multi-mode) 100BASE-FX SC

Fiber (Single-mode) 100BASE-FX SC

3.2 Connecting Ethernet Media

shielded twisted pair cables.

feet.

Page 20 of the GarrettCom P80F user manual — Proper attachment of
Page 20 · click to enlarge
Page 20
5. The LINK LED on the front of the fiber connector will illuminate when a proper connection has been established at both ends (and when power is ON in the

When using single-mode fiber cable, be sure to use single-mode fiber port connectors.

1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either

not help, ensure that the cable is connected properly and that the device on the other end

4. For Port # 1 or 1SW, if the LINK LED is not illuminated, move the switch which has a cross-over or up-link for linking to another hub or Switch.
1. Before connecting the fiber optic cable, remove the protective dust caps from the tips of

Receive (RX) port of the remote device. Begin with the color-coded strand of the cable

2. Connect the other end of the cable to the corresponding device. 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established. If this does

Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (9/125 microns for

single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the diameters of the

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

The following procedure applies to installations using ST-type fiber connectors. This

regular intervals; you must use the color-coded strand on the associated ports at

3. Connect the Transmit (TX) port (light colored post) on the Magnum Fiber port to the

unit). If LINK is not lit after cable connection, the normal cause is improper

The following procedure applies to installations using SC-type fiber connectors, i.e.,

When connecting fiber media to SC connectors, simply snap on the two square male

core and the core plus the cladding respectively). Single-mode fiber allows full bandwidth at

4. Connect the Receive (RX) port (dark colored post) to the Transmit (TX) port of the
2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue

cable polarity. Swap the fiber cables at the fiber connector to remedy this

dampened in alcohol. Make certain the connectors are clean before connecting.

connectors into the SC female jacks of the Fiber connector until it clicks and secures.

procedure applies to ports using multi-mode ST fiber connectors.

remote device. Use the non-color coded fiber strand for this.

the fiber connectors. Save these dust caps for future use.

unshielded or shielded cables and wiring may be used.

3.2.2 Connecting Fiber Optic ST-type, “twist-lock”

longer distances, about 20Km with the multi-mode SC.

3.2.3 Connecting Fiber Optic SC-type, "Snap-In"

3.2.4 Connecting Single-Mode Fiber Optic

each end of the fiber optic segment.

using multi-mode SC and SC single-mode.

for this first TX-to-RX connection.

is powered and is not defective.

situation.

Page 21 of the GarrettCom P80F user manual — Proper attachment of
Page 21 · click to enlarge
Page 21
GarrettCom P80F — Proper attachment of diagram (page 21)
Fig. 6 · Proper attachment of

The following data has been collected from component manufacturer’s (HP’s and Siemens’) web

mode 20 (0.4) 1300 9/125 -15 -31 14 28 17.5 35

-31 9.0 5.5 3.0 2.0 15.8 12.2 5.5 4.0

mode 40 (0.4) 1300 9/125 -5 -34 27 54 32.5 65

The copper ports of Magnum P80F and P80C Personal Switches will function properly

The same procedures as for multi-mode fiber apply to single-mode fiber connectors.

Receiver Sensitivity and Transmitter Power are the parameters necessary to compute

-31 9.0 5.5 2.5 2.0 14 12 5 4

  • The worst-case OPB of the fiber link must be greater than the fiber cable’s passive

with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

the power budget. To calculate the power budget of different fiber media installations using

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

  • The 100Mb fiber segment must operate in full-duplex (FDX) mode, and

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

3.2.6 Connections to NICs which support Auto-Negotiation, RJ-45 ports

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

where the “Cable Loss” for 62.5/125 and 50/125µm (m.m.) is 2.8 dB/km,

sites and catalogs to provide guidance to network designers and installers.

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

3.2.5 Power Budget Calculations for P80F Fiber Media

Magnum products, the following equations should be used:

OPB (Optical Power Budget) = PT(min) - PR(min)

Follow the steps listed in Section 3.2.2 above.

factors are both applied:

Attenuation.

Page 22 of the GarrettCom P80F user manual — Proper attachment of
Page 22 · click to enlarge
Page 22

operation is agreed and in use, the SPEED LED is illuminated steady ON. It is OFF if there is

5V, 2.0 amps is supplied with each unit. The small DC power cord from the power supply plugs

into the matching rear power jack of the P80F and P80C Personal switchess. When the power is

environments and comes in two types; one version for AC input power of 115vac at 60Hz for “-

power outlet plug, and a lightweight DC power cord to the applicable power jack on the Switch.

(FLP) coding for the 100BASE-TX signaling system. When connecting a NIC to the P80F or

communicating with a protocol other than 100BASE-TX (such as 10BASE-T). When 100Mb

Examine the power supply to make sure the version you have is the right type for your

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

d ” models, and other version of 230vac at 50 Hz for “-i ” models that have IEC power cable

The 230vac version has a small transformer integral with an IEC-type power plug for a user-

P80C, it may be necessary to reload the NIC drivers on the user device if the NIC has been

Each Magnum P80F and P80C Personal Switch is provided with an external power

supply, and has a jack for the DC power cord in the rear. A lightweight DC power cord for

AC power system. The 115vac version has a small transformer integral with a convenience

Each Magnum P80F and P80C power supply supports standard AC installation

supplied AC power cord with a convenience power outlet plug.

3.3 Powering the Magnum P80F and P80C

applied, the green PWR LED will illuminate.

connector in the external power unit.

no traffic or if 10 Mbps traffic.

Page 23 of the GarrettCom P80F user manual — Proper attachment of
Page 23 · click to enlarge
Page 23

ports, one of which may be 100Mb fiber on Model P80F. The architecture supports a dual speed

The switched RJ-45 ports are full-duplex and auto-sensing for speed. (See section 2.2).

configurations. The 10 Mbps users share a 10 Mbps traffic domain, and can “communicate with”

Each time a packet arrives on one of the switched ports, the decision is taken to either

filter or to forward the packet. Packets whose source and destination addresses on the same port

segment will be filtered, constraining them to one port and relieving the rest of the network from

The Magnum P80F and P80C units have address table capacity of 16K node addresses,

4.0 OPERATION - the function and operation of the Magnum P80F and P80C switches.

switching environment, with a built-in full-duplex “future-proof” fiber port on the Model P80F.

settings are user options for UP-LINK on RJ-45 port # 1. Half / Full duplex mode selection for

the switched fiber port and FF/AN can be done through a switch accessed from the front of the

forwarded to the appropriate port, and will not be sent to the other ports where it is not needed.

and are suitable for use in large networks. They are self-learning, so that as nodes are added or

100Mbps users as well as 100Mbps domain. Similarly, the 100Mbps traffic obeys the rules of

The Magnum P80F and DP80C Personal Switches operate in the store-and-forward

switching mode, which eliminates bad packets and enables peak performance to be achieved

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

The Magnum P80F and P80C Personal Switches provide eight switched

Packets needed for maintaining the operation of the network (such as occasional multi-cast

When the connected device is 10 Mbps, the P80F obeys all the rules of 10 Mbps Ethernet

Magnum P80F and P80C units are plug-and-play devices. There is no software

configuring to be done at installation or for maintenance. The only hardware configuration

processing them. A packet whose destination address is on another port segment will be

The Model P80C has RJ-45 copper on all the ports with auto-negotiation capability.

unit for P80F and P80C. The internal functions of both are described below.

100Mbps Ethernet, and can communicate with 10 Mb domain too.

4.1 Dual-Speed Functionality, and Switching

when there is heavy traffic on the network.

Switching, Filtering and Forwarding

packets) are forwarded to all ports.

Switching, Address Learning

Page 24 of the GarrettCom P80F user manual — 4.4 FULL or HALF Duplex, manual selection for P80C Models
Page 24 · click to enlarge
Page 24

Port # 2 or 2SW (the fiber port) has a “F - H” manual switch mounted on the front-left

All eight RJ-45 ports independently support auto-negotiation for speed in 10BASE-T

operation. (If a P80F or P80C RJ-45port is connected to a non-negotiating device, it will default

Ports # 2 have “FF - A” manual switch mounted on the front-left of the P80C Personal

negotiation takes place. The P80F or P80C advertises its capability for 10 or 100 Mbps speed,

and the device at the other end of the cable should similarly advertise / respond and both sides

of the P80F personal Switch. While in the “F” position for fiber, it forces full-duplex mode at

100Mbps. In the “H” position, it forces half-duplex mode. (Note: While fiber port is used, the

While in “A” position, both N-way switch port # 2 support auto-negotiation and full-

duplex mode is advertised for the standard 802.3u auto-negotiation session on RJ-45 switched

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

removed or moved from one segment to another, the P80F and P80C automatically keeps up

An address-aging algorithm causes least-used addresses to fall out in favor of new

will agree to the speed being used. Depending upon the device connected, this will result in

Switch. While in the “FF” position, it causes 100Mbps fixed full duplex only, which can be

When a RJ-45 cable connection is made, and each time a LINK is enabled, auto-

blinking ON indicates the port is transmitting / receiving. The port has auto-negotiated for

When the ‘LINK/ACT’ LED is ON, steady ON indicates LINK with no traffic,

frequently-used addresses. To reset the address buffer, cycle power down-and-up.

and 100BASE-TX modes. Operation is according to the IEEE 802.3u standard.

4.4 FULL or HALF Duplex, manual selection for P80C Models

to 10 Mbps speed and half-duplex mode, per the IEEE 802.3u standard).

4.3 FULL or HALF Duplex, manual selection for P80F Models

useful for using Fast Ethernet media converter (like Magnum 15E).

agreement to operate at either 10 Mbps or 100Mbps speed.

4.2 Auto-negotiation and Speed-sensing

copper port # 2 will be automatically disabled.)

with node locations.

ports.

Page 25 of the GarrettCom P80F user manual — 4.4 FULL or HALF Duplex, manual selection for P80C Models
Page 25 · click to enlarge
Page 25

The up-link (or cross-over) on the # 1 or 1SW port allows its RJ-45 cable to connect

LINK/ACTPer port, steady ON for LINK with no traffic, blinking indicates port

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

port 1SW, on the front of the Personal Switch. This port can operate either Full/Half duplex

Cascaded connections may be operated at either 10 or 100Mbps speed. The P80F

(hop count limits, etc.) for 10 Mbps domains are in effect. When the cascaded connection is

operated at 100Mbps speed, because of its full duplex and switched port capability, does not

Where an additional fiber connection (beyond the built-in fiber port as on P80F)

duplex fixed only which is useful for the fast ethernet media converter (e.g. Magnum 15E).

Magnum P80F and P80Cs have one manual crossover (MDIX up-link) switch,

for cascading to another hub or switch port. This allows repeater-to-repeater connections

without a special cross-over cable. Port 1 works the same as regular ports for 10 Mbps or

different ports. When attaching a 10 Mbps hub or switch, the Ethernet configuration rules

need any PDV calculation for distances. Two P80F and P80Cs cascaded using RJ-45 ports

may be desired, a media converter may be used. For P80F, the first two switched ports can

troublesome with auto-negotiating ports, defaulting to 100Mb half-duplex) usable in either

F/H: ON = Full-Duplex and Link, OFF = Half-Duplex and / or no Link.

even supports cascaded connections of both 10 Mbps and 100Mbps at the same time on

SPEEDPer port, ON = 100Mbps; OFF = 10 Mbps (when LINK is made)

Whereas for P80C the switched port 2 at “F” position supports 100Mbps Full

be set to FDX manually, making typical 100Mb media converters (which can be

4.5 LED’s PWR: Illuminates GREEN, steady on when power applied.

ERRORIndicates the self-test at power up was not successful

will auto-negotiate to operate the connection at 100Mb/s.

is transmitting and receiving.

100Mbps speed auto-sensing connections.

HDX or FDX mode as set by the user.

4.6 Up-link Port # 1 or 1SW

4.7 Use with Media Converters

mode.

Page 26 of the GarrettCom P80F user manual — 5.0 TROUBLESHOOTING
Page 26 · click to enlarge
Page 26

known good device. Verify whether or not the problem is corrected. If not, go to Step

below prior to contacting your supplier. However, if you are unsure of the procedures described

Installation Section of the applicable chapter of this manual. Also check to make sure

3. Make sure that an AC power cord is properly attached to each Magnum P80F & P80C

Personal Switch product, it is recommended that the problem device is replaced with a

5 below. If the problem is corrected, the Magnum P80F & P80C Personal Switch and

Should problems develop during installation or operation, this section is intended to

help locate, identify and correct these types of problems. Please follow the suggestions listed

in this section or if the Magnum P80F & P80C Personal Switch is not performing as expected,

4. If the problem is isolated to a network device other than the Magnum P80F & P80C
5. If the problem continues after completing Step 4 above, contact your supplier of the

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

All Magnum Ethernet products are designed to provide reliability and consistently

1. If difficulty is encountered when installing or operating the unit, refer back to the

high performance in all network environments. The installation of Magnum P80F & P80C

functioning electrical outlet. Use the PWR LEDs to verify each unit is receiving

Magnum P80F & P80C Personal Switch unit or if unknown, contact GarrettCom,

Personal Switch is a straightforward procedure (see INSTALLATION, Section 3.0); the

power.

do not attempt to repair the unit; instead contact your supplier for assistance or contact

Personal Switch unit. Be certain that each AC power cord is plugged into a

2. Check the cables and connectors to ensure that they have been properly

connected and the cables/wires have not been crimped or in some way

impaired during installation. (About 90% of network downtime can be

Inc.by fax, phone or email (support@garrettcom.com) for assistance.

that the various components of the network are interoperable.

operation is also straightforward and is discussed in Section 4.

attributed to wiring and connector problems.)

its associated cables are functioning properly.

5.1 Before Calling for Assistance

5.0 TROUBLESHOOTING

GarrettCom Customer Support.

Page 27 of the GarrettCom P80F user manual — 5.0 TROUBLESHOOTING
Page 27 · click to enlarge
Page 27
3. It is useful to include other network equipment models and related hardware, including

personal computers, workstations, terminals and printers; plus, the various network

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form. Please

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

2. An accurate list of GarrettCom product model(s)involved, with serial number(s).

products that are under warranty at no charge, and will return the warranty-repaired units to

Include the date(s) that you purchased the products from your supplier.

5.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization

4. A record of changes that have been made to your network configuration prior

d. Any particular application that, when used, appears to create the problem;

GarrettCom will carefully test and evaluate all returned products, will repair

the sender with shipping charges prepaid (see Warranty Information, Appendix A, for

complete details). However, if the problem or condition causing the return cannot be

to the occurrence of the problem. Any changes to system administration

1. A complete description of the problem, including the following points:

Failure symptoms, including a full description of the problem.

Please be prepared to provide the following information.

(RMA) number. To obtain an RMA number, please use this URL -

Name and phone number of your contact person.

Packing List Number (or Sales Order Number)

duplicated by GarrettCom, the unit will be returned as:

c. The components involved in the problem;

procedures should all be noted in this record.

a. The nature and duration of the problem;

b. Situations when the problem occurs;

have the following information readily available:

Serial Number (or Invoice Number)

Name of your company / institution

5.2 When Calling for Assistance

media types being used.

Your shipping address · Date of installation · Product name

Page 28 of the GarrettCom P80F user manual — APPENDIX A: WARRANTY INFORMATION
Page 28 · click to enlarge
Page 28
1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for
2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

Should you need to ship the unit back to GarrettCom, please follow these instructions:

shipping protection. ( You may retain all connectors and this Installation Guide.)

Magnum P80F & P80C Personal Switches Installation and User Guide (07/03)

GarrettCom reserves the right to charge for the testing of non-defective units under

warranty. Testing and repair of product that is not under warranty will result in a customer

Please complete the warranty card as this acts as a product registration, and mail

workmanship for a period of three (3) years from the date of shipment by GarrettCom.

components in the products that prove to be defective at no charge other than shipping

This warranty will not be effective if, in the opinion of GarrettCom, the product

GarrettCom reserves the right to make a charge for handling and inspecting any

GarrettCom, Inc. warrants its products to be free from defects in materials and

has been damaged by misuse, misapplication, or as a result of service or modification

During this warranty period, GarrettCom will repair or, at its option, replace

This material may cause electro-static shock damage to the unit.

and handling, provided that the product is returned pre-paid to GarrettCom.

3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to:

product returned for warranty repair which turns out not to be faulty.

APPENDIX A: WARRANTY INFORMATION

it to GarrettCom within two weeks of your purchase.

No Problem Found.

5.4 Shipping and Packaging Information

47823 Westinghouse Dr.

Attn.: Customer Service

GarrettCom, Inc.

other than by GarrettCom.

(user) charge.

Fremont, CA 94539

Ask about the GarrettCom P80F

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom P80F

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom P80F manual PDF

28 pages·198 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…