EN
GarrettCom logo
Official user manual

GarrettCom 6K25

67 pages·850 KB·Switch·PDF·ENDEFRITNLJA
GarrettCom 6K25
Table of Contents 80 sections Managed Fiber Switch · Installation and User Guide · Magnum 6K25 · Hardware · … ShowHide
Managed Fiber Switchp.1Installation and User Guidep.1Magnum 6K25p.1Hardwarep.1Magnum ™ 6K25p.2email [email protected]p.3Phone (510) 438-9071p.35.2.11 New PoE(Power Pass-through), model P6KP8-RJ45 8-port ................49p.55.2.13a GBIC-LXSC & ZXSC single-mode SC Connector................52p.56.3 Return Material Authorization (RMA) Procedure..............................54p.56.4 Shipping and Packaging Information.................................................54p.5APPENDIX A: WARRANTY INFORMATION .........................................55p.5APPENDIX B : INTERNAL DC POWER SUPPLY OPTIONS.................55p.5APPENDIX C: INTERNAL DC DUAL-SOURCE POWER OPTION ......58p.5Revisionsp.6APR, 07p.7INDUSTRIAL NETWORKING PRODUCTSp.7"DESIGNED AND MANUFACTURED IN THE USA"p.7The Magnum Linep.7OVERVIEWp.71.1 Technical Specificationsp.81.0 SPECIFICATIONSp.8Alarm Contact (Optional)p.10Magnum Managed Fiber Switchp.11MODEL DESCRIPTIONp.112.1 Inspecting the Package and Productp.142.0 Introductionp.142.2 Product Description - Magnum 6K25 Managed Fiber Switchp.152.2.1 Magnum 6K25 and 6K25R chassisp.162.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb fiberp.17ACTp.17F/Hp.17F/H LK LK LK LKp.172 4 6 8 LK LK LK LKp.172 4 6 8 LK LK LK Lp.17ACp.172.2.3 Eight-Port Copper Module, 6K8-RJ45p.1810/10 LK/AC 1p.193 F/H POEp.1910/10 LK/ACp.194 FULL/HALFp.192 4 6 F/ H POEp.196KP8-45RJp.196KP8 -45RJp.19LINK LK / ACT 2p.192.2.6 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45 and 2@100Mbp.20fiber 4@RJ-45 + 2@ 100Mb ST or SCp.2010/100 LKp.20F/H ACTp.202 6 TX RX TX LK RX LKp.202.2.7 Four-Port 10 Mb mm Fiber ST Modulesp.212.2.8 Gigabit (1000Mbps) port modulesp.21TX LK RXp.21F/p.21TX RX LKp.21TX RX Lp.21F/ ACTp.2210/100 Lp.222.2.9 Packet Prioritization, 802.1p QOSp.222.2.10 Frame Buffering and Flow Controlp.222.2.11 Managed Network Software ( MNS-6K ) for Magnum 6K25-Seriesp.23GarrettCom proprietary MIBs for SNMP-p.232.4 Applicationsp.263.1 Locating Magnum 6K25 Switchesp.283.0 Installationp.283.2 Connecting Ethernet Mediap.29Copper:p.293.2.3 Connecting Single-Mode Fiber Opticp.301 3 5 7 10/100 LKp.313.3 Table-Top or Shelf Mountingp.31GARRETTp.3110/100 L 2 4 6 8 F/ H ACp.323.5 6K25 Port Module (6KPM) Installationp.343.5.1 Preparation for Installing and Removing 6KPMsp.35STOP!!!p.353.5.2 Installing 6KPM Cards in the Magnum 6K25p.36screen plates installed inside the chassis cover using brackets and screwsp.393.6 Connecting the Console Terminal to Magnum 6K25 (Management)p.41Pin Signal Descriptionp.41OFp.41
Page 1 of the GarrettCom 6K25 user manual — Managed Fiber Switch
Page 1 · click to enlarge
Page 1
GarrettCom 6K25 — Managed Fiber Switch diagram (page 1)
Fig. 1 · Managed Fiber Switch

Managed Fiber Switch

Installation and User Guide

Magnum 6K25

Hardware

Page 2 of the GarrettCom 6K25 user manual — Hardware
Page 2 · click to enlarge
Page 2

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is

Magnum 6K25 Switch products, consult Section 6, Troubleshooting, of

serviceable parts. Attempted service by unauthorized personnel shall

render all warranties null and void. If problems are experienced with

of this publication may be reproduced without prior written permission from

Copyright © 2006 GarrettCom, Inc. All rights reserved. No part

Installation and User Guide

Managed Fiber Switch

UL is a registered trademark of Underwriters Laboratories

Magnum ™ 6K25

Part #84-00123 (Rev. D)

Hardware

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

a registered trademark of GarrettCom, Inc.

Printed in the United States of America.

this User Guide.

GarrettCom, Inc.

Trademarks

Page 3 of the GarrettCom 6K25 user manual — Phone (510) 438-9071
Page 3 · click to enlarge
Page 3

This equipment generates, uses and can radiate frequency energy and if

not installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested

and found to comply with the limits for a Class A computing device in accordance

with the specifications in Subpart J of Part 15 of FCC rules, which are designed to

provide reasonable protection against such interference when operated in a

commercial environment. Operation of this equipment in a residential area is

likely to cause interference, in which case the user at his own expense will be

Cet appareil respecte toutes les exigences du Réglement sur le matériel du

Please use the mailing address, phone and fax numbers and email address listed

required to take whatever measures may be required to correct the interference.

This Class A digital apparatus meets all requirements of the Canadian

Websitehttp://www.GarrettCom.com

Radio Frequency Interference Statement

email [email protected]

below: GarrettCom, Inc.

47823 Westinghouse Dr. Fremont, CA 94539-7437

Phone (510) 438-9071

Interference-Causing Equipment Regulations.

Canada. Cet appareil est Classe A..

Show 4 more labels / short text on this page
Federal Communications Commission · Fax (510) 438-9072 · Canadian Emission · Contacting GarrettCom, Inc
Page 4 of the GarrettCom 6K25 user manual — email support@garrettcom.com
Page 4 · click to enlarge
Page 4
Page 4 of the GarrettCom 6K25 user manual — email support@garrettcom.com
Page 5 of the GarrettCom 6K25 user manual — 5.2.13a GBIC-LXSC & ZXSC single-mode SC Connector................52
Page 5 · click to enlarge
Page 5

5.1 Inspecting the Package and Product 40

5.2 6KPM Module Description 41 5.2.1 6KP6-RJMST, Combo Module 41 5.2.1a 6KP6-RJ10ST, Combo Module 42 5.2.1b 6KP4-F10ST, Module 42 5.2.1c 6KP4-FLSTFX, Module 43 5.2.2. 6KP6-RJMSC FX-SC connector 43 5.2.3 6KP6-RJSSC connector 44 5.2.4 6KP6-RJSSCL single-mode connector 44 5.2.4a 6KP6-RJ10ST connector 45 5.2.5 6KP8-MTRJ, Form-factor 45 5.2.5a 6KP6-MT10ST, MTRJ Small-Form-Factor and port 46 5.2.6 6KP8-45MT, MTRJ Small-Form-Factor 46 5.2.7 6KP8-MLC, Form Factor 47 5.2.8 6KP8-45LC,LC small-form factor Connector 47 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port 48 5.2.10 New PoE(Power Inside), model PI6KP8-45RJ (MDIX), 8-port 49

5.2.11 New PoE(Power Pass-through), model P6KP8-RJ45 8-port 49

5.2.12 6KP8-45-2MT, MTRJ Small-Form-Factor 50 5.2.12a 6KP8-45-2LC, single-mode FX , LC Small-Form-Factor 51 5.2.13 GBIC-SXSC Gigabit fiber(1000Mb), SC Connector 51

5.2.13a GBIC-LXSC & ZXSC single-mode SC Connector 52

5.2.14 6KM-BLNK ...............................................................................52 6.0 TROUBLESHOOTING.......................................................................52

6.1 Before Calling for Assistance.............................................................53

6.2 When Calling for Assistance..............................................................53

6.3 Return Material Authorization (RMA) Procedure..............................54

6.4 Shipping and Packaging Information.................................................54

APPENDIX A: WARRANTY INFORMATION .........................................55

APPENDIX B : INTERNAL DC POWER SUPPLY OPTIONS.................55

APPENDIX C: INTERNAL DC DUAL-SOURCE POWER OPTION ......58

Page 6 of the GarrettCom 6K25 user manual — Revisions
Page 6 · click to enlarge
Page 6

05/07: Minor updates to notes for Power Substations connections 04/06: minor updates as PoE modules option added on Sec 5.2.10/11 10/05: minor updates as MDIX support added on all RJ-45 port modules 01/05: minor updates and tweak on LC port modules 06/04: New port modules has been added and updates on Alarm contact 02/04: Minor update, and added Section 3.4.1, Alarm Contact option. 11/03 : Minor updates, Network standards & Console port pin Assign. 03/03 : Minor updates on power budget calculations , Gigabit fiber Rev D 10/02 : Updated the Rack Mount options and brackets, Section 3.3

Rev C 06/02Updated the port settings configuration at sec 4.3, added

Magnum 6K25’s MNS Software manual access information at sec 2.2.9

Appendix B and C with 24VDC and 125VDC Power Supply option.

Rev B 04/02Updated the Rack-mounting, -48V DC options and

Rev A 12/01 : This rev. is the initial release of the 6K25 manual.

Revisions

Page 7 of the GarrettCom 6K25 user manual — OVERVIEW
Page 7 · click to enlarge
Page 7

GarrettCom, Inc. offers the premium-quality Magnum™ line of

INDUSTRIAL conectivity products with industry-standard functionality and

built-in fiber configurability. Magnum products are designed for use in

demanding Industrial Grade, Carrier Class, POWER UTILITY and OEM

4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto-negotiating

Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed and mixed-media

mP62 and P62F “Outdoor” Ethernet SwitchES, for temperature uncontrolled locations, 6 10/100

Personal Hubs, 10Mb series 8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-

6K-Series Managed Field Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports, mix-and

APR, 07

Media Converters, 10Mb and 100Mb series, All media combinations, incl. fiber ST, SC, mm.,

Personal Hubs, 100Mb or 10/100Mb 8-port, with 2 switched ports (1 fiber built in)

INDUSTRIAL NETWORKING PRODUCTS

"DESIGNED AND MANUFACTURED IN THE USA"

The Magnum Line

applications where reliability is a primary consideration.

Stackable Concentrators, SNMP optional, 13-Ports

OVERVIEW

Dual Speed 8-port and 16-port, 10/100 auto-sensing HUBS

Repeater Port Modules (RPMs), 6 types for Ethernet media

Mixed-Media Fiber Hub, 16-port, 10/100 auto-sensing

The “X-line” of configurable MiXed Media products:

DX-Series Serial Device Routers, Ethernet and Serial

port and 4 or 5-Port Personal Hubs, w/ man. up-link sw.

match. Features SFF fiber and DC power in 1U units.

and 2 100Mb fiber ports, can be connected in strings

8 port dual-speed, Auto-negotiable with fiber option

Mini-Concentrators, 7 Ports, Repeaters, 2-Ports

COAX Transceivers, 10Mb series

types, full switching performance.

Personal Switches, 10/100Mb

full switching performance.

single mode

Page 8 of the GarrettCom 6K25 user manual — 1.0 SPECIFICATIONS
Page 8 · click to enlarge
Page 8
Switching Processing TypeStore and Forward with IEEE 802.3x full-

100BASE-FX, full-duplex, single-mode - 20.0 km (66K25 ft)

100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft)

Unshielded twisted pair - 100 m (328 ft)

10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)

10BASE-FL single-mode fiber optic - 10 km (32,810 ft)

10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)

100BASE-TX (CAT 5 UTP) - 100 m (328 ft)

100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft)

1000BASE-T (CAT5E or higher is recommended) - 100 m (328 ft) 1000BASE-SX, full-duplex, multi-mode(62.5µm cable) - 220m 1000BASE-SX, full-duplex, multi-mode(50µm cable) - 550m 1000BASE-LX, full-duplex, single-mode(62.5µm cable) -5Km

Packet buffer size240KB for 10/100 and 120KB for 1000Mb

100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft)

100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)

Shielded twisted pair - 150 m (492 ft)

Shielded twisted pair - 150 m (492 ft)

Address Table Capacity4K node, self-learning with address aging

15 µs + packet time (10 to 10 Mbps, and 10 to 100Mbps)

IEEE 802.3z1000BASE-X Ethernet(Auto-negotiation)

Maximum Standard Gigabit Ethernet Segment Lengths:

Maximum Standard Fast Ethernet Segment Lengths:

Data Rate10Mbps,100Mbps and 1000Mbps

Network Standards and Compliance, hardware

Ethernet V1.0/V2.0 IEEE 802.310BASE-T,

Maximum 10 Mbps Ethernet Segment Lengths

duplex flow -control, non-blocking

Latency5 µ s + packet time (100 to 100Mbps)
IEEE 802.1wRapid Spanning tree protocol
IEEE 802.3u100Base-TX, 100BASE-FX
IEEE 802.3ab1000BASE-X Ethernet
Gigabit Ethernet1, 488,000 pps
IEEE 802.1dSpanning tree protocol

Filtering / Forwarding Rate:

Fast Ethernet148,800 pps
IEEE 802.1pPriority protocol
IEEE 802.1qVLAN Tagging
IEEE 802.3xFlow Control

1.1 Technical Specifications

Ethernet:14,880 pps

1.0 SPECIFICATIONS

Performance

Page 9 of the GarrettCom 6K25 user manual — 1.1 Technical Specifications
Page 9 · click to enlarge
Page 9

DB-9 for RS-232 “ null-modem “ cable (sometimes called an Xmodem cable)

Fiber Port, ST-type (twist-lock):Fiber multi-mode, 10Mb 10BASE-FL

Fiber Port, MTRJ-type (plug-in):SFF Fiber multi-mode100BASE-FX

Fiber Port, ST-type (twist-lock)Fiber optic m.-mode, 100BASE-FX

Fiber Port, SC-type (snap-in):Fiber optic multi-mode, 100BASE-FX

EnclosureRugged High strength metal. Suitable for stand-alone

with adjacent manual ON-OFF switch (on AC models only)

Fiber Port, SC-typeFiber optic single-mode, 100BASE-FX

Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX

AC Power ConnectorIEC-type, male recessed at rear of chassis,
IEC 60068 “Type Test” rating-40 ° to 185 ° F (-40 ° to 85 ° C)
Ambient Relative Humidity5% to 95% (non-condensing)
Power Consumptionsame as for AC models, see above

UL 60950 “Component Parts” temp. rating: 130° F (55°C)

-48VDC Power Input Voltage-36 to -70 VDC
125VDC Power Input Voltage88 to 300VDC Std. Terminal Block : “ -, GND, + ”

60 watts max (for a fully loaded fiber model) 35 watts for a fully-loaded copper only model

24VDC Power Input Voltage20 to 36VDC
LKSteady ON when media link is operational
Dimensions1.70in. H x 17.0in. W x 9.0in. D

4.32cm H x 43.2cm W x 22.9cm D Cooling method: Fan cooled, @ 3@ 7 cfm ea.

Fiber Multi-mode connector types supported:

Fiber Port, 1000BASE-FX, GBIC modules

Fiber Port, 1000BASE-FX, GBIC modules

Altitude-200 to 13,000 ft. (-60 to 4000m)
Conformal Coating optionRequest quote
Input Voltage100 to 240 VAC (auto-ranging)

OFF = Half-Duplex Mode

Input Frequency47 to 63 Hz (auto-ranging)
FDX/HDXON = Full-Duplex Mode
ACTON with receiver port activity
Storage-40 ° to 185 ° F (-40 ° to 85 ° C)

Fiber Single-mode connector types:

Power Consumption55 watts typical
100/10ON = 100Mbps speed OFF = 10 Mbps

DC Power Supply (Options)

LEDsPer Port
Show 5 more labels / short text on this page
or rack-mounting · Management Console connector · Operating Environment · Power Supply (Internal) · Packaging
Page 10 of the GarrettCom 6K25 user manual — Alarm Contact (Optional)
Page 10 · click to enlarge
Page 10

are SPST NC Form-C relays, and an open condition indicates abnormal status. The

Dual Source options (for continuity of operation when either of the DC input sources

Alarm Contact option is offered as a configuration option. The two alarm contacts

For DC internal power supplies at –48VDC, 24VDC and 125VDC, including

The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45

ports., and eliminate the use of cross-over cable between the devices. Also port-

specific user settings (such as FDX or HDX, copper 10/100 speed) can be fixed

Hardware Alarm monitors internal power on the main board, and the Software

See also Note for Power Substations in Section 3.2.4, 3.6.1, and 5.2.9

IEEE 1613 Class 2 Environmental Standard for Electric Power Substations

IEC 61850 EMC and Operating Conditions Class C for Power Substations

UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class A

WarrantyThree years, return to factory Made in USA

Alarm is activated by one or more user-selected software traps.

NEBS Level 3 and ETSI Certified for Carrier Central Offices

Email sales@GarrettCom.com for details.

NEBS Testing and CertificationNEBS certified

are interrupted), see Appendices B and C.

Per-port MDI or MDIX on RJ-45

Alarm Contact (Optional)

using software commands.

Agency Approvals

Page 11 of the GarrettCom 6K25 user manual — MODEL DESCRIPTION
Page 11 · click to enlarge
Page 11

the power input connectors are in the rear. Two sets of LEDs (both rear and front) provide

May be configured with a selection of 10/100/1000 6K25 fiber and copper port

connector types, 25 total ports max. Wire speed filtering and forwarding across all ports,

6KP8-45-2MT “6+2” module, w/six RJ-45 ports and two 2km mm MTRJ connectors

6KP8-45-2SLC “6+2” module, w/six RJ-45 ports and two 100Mb 15km sgl. mode FX LC connectors

rack-mounting brackets. For licensed managed networks software, see MNS materials.

Magnum 6K25R“Reverse” model, same as Model 6K25 except the user ports and

6KP4-FXST “2+2” 100Mb Fiber module, w/ four 100Mb 2km FX ST connectors

6KP8-45LC “4+4” module, w/four RJ-45 ports and four 2km mm LC connectors

802.3x flow control, 802.1p priority packet processing, self-learning 4K-node address table, large 240KB packet buffers for 10/100 and 120KB for 1000Mb. Plug-and-play

switching services, front-mounted LEDs, internal auto-ranging AC power supply, 19"

Each Magnum 6K25 and 6K25R base unit has four port module slots. The first

6KP4-FLSTFX “2+2” ST Fiber module, w/ two 100Mb & two 10Mb ports, 2km 6KP8-45MT “4+4” module, w/four RJ-45 ports and four 2km mm FX MT-RJ’s

three (A,B,C) may be one of the modules below, one (slot D) may only be a Gigabit

6KP4-F10ST “2+2” 10Mb Fiber module, w/ four 10Mb 2km FL ST connectors

6KP6-RJSSC “4+2” module, w/four RJ-45 ports and two 20km Sgl.m FX SC’s

6KP6-RJSSCL “4+2” module, w/four RJ-45 ports and two 40km Sgl.m FX SC’s

6KP6-MT10ST “4+2” module, w/four MTRJ ports and two 10Mb 2km FL ST’s 6KP6-RJ10ST “4+2” module, w/four RJ-45 ports and two 10Mb 2km FL ST ‘s

Magnum 6K25-125VDCSame as 6K25 except the power input is 125VDC
Magnum 6K25R-125VDCSame as 6K25R except the power input is 125VDC

6KP8-MTRJ SFF Fiber module, w/eight 100Mb mm FX MT-RJ connectors

6KP8-SLC SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors

6KP8-RJ45 TP Module, w/eight 10/100Mbps auto-negotiating RJ-45 ports

6KP6-RJMST “4+2” module, w/four RJ-45 ports and two 2km mm FX SC’s

6KP6-RJMSC “4+2” module, w/four RJ-45 ports and two 2km mm FX ST‘s

Magnum 6K25-48VDCSame as 6K25 except the power input is –48VDC
Magnum 6K25R-48VDCSame as 6K25R except the power input is –48VDC
Magnum 6K25R-24VDCSame as 6K25R except the power input is 24VDC

6KP8-MLC SFF Fiber module, w/eight 100Mbps mm FX LC connectors

Magnum 6K25-24VDCSame as 6K25 except the power input is 24VDC

Magnum Managed Fiber Switch

Magnum 6K25 Magnum 6K25 Managed Fiber Switch, base unit.

module. Select up to four port modules per base unit.

duplicate status data for viewing from either side.

MODEL DESCRIPTION

1.2 Ordering Information

Magnum 6K25 Port Modules

Configuration Options:

Page 12 of the GarrettCom 6K25 user manual — Magnum Managed Fiber Switch
Page 12 · click to enlarge
Page 12

GBPM-COTX One slot Gigabit 6K module for 6K25 Switches, uses one 6K25 slot and

GBIC-SXSC GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-SX

GBIC-LXSC40 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-ZX

GBIC-LXSC70 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-ZX

New P6KP8-RJ45 8 port PoE module for 6ks with 48vdc PS, w/eight PoE power source

New P6KP8-45MLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP8-45-2MT “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP8-452SLC “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

provides one GBIC open transceiver port for a user-selectable GBIC transceiver module

GBIC-LXSC10 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-

GBIC-LXSC25 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-

CONSOLE CBL Industry standard serial cable, DB-9 connectors for RS-232 “ null-

CONSOLE USB Console attachment cable, serial to USB, cable with one DB9 for the

New P6KP8-45MT “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP8-45SLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX MTRJ connectors

modem “ connection (sometimes called an Xmodem cable), used to connect a PC or a

10/100 auto-negotiating auto cross RJ-45 ports. New P6KP8-45RJ “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

6K PoE Modules with 48VDC Pass-Through Configuration options: only one A, B or C module slot of 6K-Series switch with

GBIC transceiver module for use in GBPM-COTX, one LX port with mm SC fiber

GBIC-TP GBIC transceiver module for use in GBPM-xOTX, one 802.3ab

1000BASE-T port, RJ-45 connector 6KM-BLNK Blank cover for one 6K25 (A,B,or C) module slot opening in a

managed Switch and a USB interface for the USB connector to a PC.

48VDC power input may be configured with a PoE Modules

LX/LH port with 1310nm sgl. mode SC(10km) fiber connector

LX/LH port with 1310nm sgl. mode SC(25km) fiber connector

source and four 10/100 auto-negotiating auto cross RJ-45 ports

port with 1550nm, sgl. mode SC(40km) fiber connector

port with 1550nm, sgl. mode SC(70km) fiber connector

source and four 100 Mb 2km mm FX MTRJ connectors

For Gigabit module configuration options

source and four 100 Mb 2km mm FX LC connectors

source and four 100 Mb 15km sm FX LC connectors

character terminal to the Management port.

port with mm SC fiber connector

Magnum 6K25 or 6K25R chassis

connector

Page 13 of the GarrettCom 6K25 user manual — Magnum Managed Fiber Switch
Page 13 · click to enlarge
Page 13

New PI6KP6-RJSSCL “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four POE power

New P6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJSSCL “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New 6K125VDC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a

New PI6KP8-45MLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-45SLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-45-2MT “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-452SLC “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New 6KAC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a full-

New PI6KP8-45RJ “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-45MT “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX MTRJ connectors

Configuration optionsonly one A, B or C module slot of 6K-Series switch with

6K PoE Modules with 48VDC Power Inside NOTE: For configuring in 6K Switches having AC /125VDC power input

GarrettCom, Inc. reserves the right to change specifications, performance

48VDC power input may be configured with a PoE Modules

source and four 10/100 auto-negotiating auto cross RJ-45 ports

full-width rack-mount 6K switch with 125VDC power input.

characteristics and/or model offerings without notice.

source and four 100 Mb 2km mm FX MTRJ connectors

source and four 100 Mb 15km Sm FX LC connectors

source and two 100 Mb 2km mm FX ST connectors

source and two 100 Mb 2km mm FX SC connectors

source and two 100 Mb 20km sm FX SC connectors

source and two 100 Mb 40km sm FX SC connectors

source and four 100 Mb 2km mm FX LC connectors

source and four 100 Mb 15km sm FX LC connectors

source and four 100 Mb 15km Sm FX LC connectors

source and two 100 Mb 2km mm FX ST connectors

source and two 100 Mb 2km mm FX SC connectors

source and two 100 Mb 20km sm FX SC connectors

source and two 100 Mb 40km sm FX SC connectors

width rack-mount 6K switch with AC power input.

source and two 10 Mb 2km sm FL ST connectors

source and two 10 Mb 2km sm FL ST connectors

Page 14 of the GarrettCom 6K25 user manual — 2.0 Introduction
Page 14 · click to enlarge
Page 14

In the event there are items missing or damaged, contact the party from whom

product; notify the carrier of any damage that you believe occurred during shipment or

delivery. Inspect the contents of this package for any signs of damage and ensure that

Remove the items from the shipping container. Be sure to keep the shipping

shipping container if possible. Refer to Section 6, Troubleshooting, for specific return

Examine the shipping container for obvious damage prior to installing this

container should you need to re-ship the unit at a later date. To validate the product

you purchased the product. If the unit needs to be returned, please use the original

warranty, please complete and return the enclosed Product Registration Card to

(configured with user-selected port module options)

1 Magnum 6K25 Managed Fiber Switch, base unit

1 AC Power Cord (U.S. and other 115 VAC only)

1 Set of metal “Ears” for 19” rack mounting

1 Installation and User Guide (this manual)

2.1 Inspecting the Package and Product

1 Product Registration Card

This package should contain:

GarrettCom, Inc. as soon as possible.

the items listed below are included.

2.0 Introduction

procedures.

Page 15 of the GarrettCom 6K25 user manual — 2.2 Product Description - Magnum 6K25 Managed Fiber Switch
Page 15 · click to enlarge
Page 15

The Magnum 6K25 has up to 25 ports capacity, all of which may be configured

Gigabit ports. It also allows a mix of 10/100Mb RJ-45 (copper) ports and a fiber Gigabit

application and Ethernet cabling requirements. Even evolving mixed-media requirements

LEDs in the front and the power input and management console connector in the rear) or

The Magnum Managed Fiber Switch boosts the performance of large Ethernet

LANs, typically serving as a “backbone” switch. It has the flexibility to handle a mix of

as fiber ports, but still offers a space-saving rack-mount chassis that is only 1U (1.70in.

port in the same unit. This flexibility is achieved via a family of 6K25 port modules for

selections using GBICs. These modules can be factory configured in a base chassis unit

power –inside PoE modules and allows the users to select a wide option of combo PoE

modules to support 802.3af pd devices. See details in sec 5.2.10 and 5.2.11. The Power

wireless access points, IP phones) that comply with the IEEE 802.3af PoE standard. The

duty applications. The chassis mounting rack style may be “regular” (with the ports and

performance switching services for both “smooth” streaming and “bursty” data traffic.

for 10Mb and 100Mb fiber and copper as well as Gigabit ports can be handled by the

both fiber and twisted-pair switched ports along with Gigabit backbone port options.

(or may be changed in the field by trained technicians) to adapt the unit to the user’s

Sourcing Equipment (PSE), and are fully compatible with Powered Devices (PD)(e.g

PoE switch ports have an auto-sensing algorithm, so that they provide power only to

802.3af, PoE end devices. PoE is managed by a multi-stage handshake to protect

The packaging and power-input options target the Magnum 6K25 at heavy-

or 4.32cm) high. The “mixed-media” capability allows user selection of all popular

copper and fiber-built-in (emphasizing Small Form Factor fiber for high fiber port

The 6K25 managed switches also provides PoE option via Power-pass-through and

discontinue supplying power when the PoE powered devices are disconnected, and

2.2 Product Description - Magnum 6K25 Managed Fiber Switch

flavors of fiber port connectors and modes, including even 10Mb fiber along with

density), 6-port modules for fiber and RJ-45 combinations, and 1Gb port module

support the 802.3af PoE PSE standard for over-current protection, under-current

equipment from damage and to manage power budgets.The PoE ports will

Industry-standard IEEE 802.1p QOS prioritization is included, providing high

detection, and fault protection.

Magnum 6K25 product.

Page 16 of the GarrettCom 6K25 user manual — 2.2.1 Magnum 6K25 and 6K25R chassis
Page 16 · click to enlarge
Page 16

accommodated include standard 19” RETMA, ETSI, and 23” Telco. Input power may be

performance plug-and-play hardware operation, 802.1p packet prioritization in hardware,

port slots (A, B, and C) and one Gb-only slot (D) for configuration flexibility. Slots A, B

and C may be configured with any of a large selection of fiber and copper port types and

Designed for use in network traffic centers, the Magnum 6K25 Managed Fiber

The Magnum 6K25 is a 19” rack-mountable Ethernet Switch with three eight-

even one Gb port. Slot D may be configured with a Gb module that accepts GBICs. The

are normally factory installed, but may be changed or added in the field. (See Section 5)

Status LEDs are part of each port module and are viewable when connecting

“Reverse” rack-mount models, there is a duplicate set of LEDs on the other (front) side

“Reverse” (with the ports and LEDs and the power-input and the management console

learned, maintained and aged out, adapting the switching services to network changes.

and industry-standard managed networks software functionality, all in convenient 1U

combinations of types, typically eight ports per module, but sometimes 6 or 4 ports or

variety of applications, especially using fiber media. The Magnum 6K25 port modules

GarrettCom 6K25 — 2.2.1 Magnum 6K25 and 6K25R chassis diagram (page 16)
Fig. 2 · 2.2.1 Magnum 6K25 and 6K25R chassis

port types configurable using the 4 slots allows the 6K25 to efficiently serve a large

Switches are easy to install and use. Addresses of attached nodes are automatically

LEDs provide status information on each port. The Magnum 6K25 provides high

the Ethernet media. A “regular” rack-mount 6K25 is shown in Figure 2.2.1a. On

connector all in the rear and a duplicate set of LEDs in the front). Rack widths

AC, or –48VDC for Telco environments, or 24VDC for Industrial applications.

Figure 2.2.1a“Regular” 6K25 front view, configured for 24 +1 Gb ports

2.2.1 Magnum 6K25 and 6K25R chassis

rack-mount packages.

Page 17 of the GarrettCom 6K25 user manual — ACT
Page 17 · click to enlarge
Page 17

speed (100Mb), mode, and connector type. Models are available with Small Form Factor

(SFF) are multi-mode MT-RJ or LC-

default) to operate in full-duplex mode for best fiber distance and performance. Using the

2.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb fiber

6K8-MTRJ (to the left) and

set-up of the software (See Magnum 6K25 MNS Software Manual) for the flexibility to

There are three LED’s per fiber port. The Link (LK) LED indicates “ready for

Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK)

In an eight-port SFF fiber port module, all of the fiber ports are of the same

type connectors, and single-mode

The 100Mb fiber eight-

6K25’s normally are set (factory

6K25’s MNS software, the user may select full- or half-duplex mode per-port through

operation” on that port when lit, the F/H LED indicates operation in full-duplex mode

indicator for that port must be ON (indicating there is a powered-up device at the other

for normal status viewing from that direction. Of course, with management, the port

6K8-MLC or -SLC (below)

port modules for the Magnum

when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving

end of the cable) in order for a LK LED to provide valid indications of operating

Fig.2.2.2 :

LC-type connectors.

adapt to any FDX or HDX type of Fast Ethernet devices).

ACT

F/H

ACT

ACT

ACT

F/H

ACT

F/H

ACT

F/H

ACT

F/H

F/H

F/H

ACT

F/H

status data is also available in software.

1 3 5 7

F/H LK

2 4 6 8 LK LK LK LK

2 4 6 8 LK LK LK L

2 4 6 8 LK LK LK L

1 3 5 7

conditions on that port.

ACT

ACT

F/H

F/H

ACT

F/H

ACT

F/H

AC

F/H

AC

AC

F/H

AC

F/H

SFF Fiber Port · Modules,

Page 18 of the GarrettCom 6K25 user manual — 2.2.3 Eight-Port Copper Module, 6K8-RJ45
Page 18 · click to enlarge
Page 18
GarrettCom 6K25 — 2.2.3 Eight-Port Copper Module, 6K8-RJ45 diagram (page 18)
Fig. 3 · 2.2.3 Eight-Port Copper Module, 6K8-RJ45

(See Section 4.3 for auto-negotiation and MDIX details). The auto-crossover feature will

port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that port

into an RJ-45 port and the Link (LK) indicator for that port must be ON (indicating there

crossover(MDIX) for operation at 10 or 100Mb speed in full- or half-duplex mode, i.e.,

each independently selects a mode and speed to match the device at the other end of the

On the model 6K8-RJ45 module, there are four LEDs for each port, two in the

connector and two separate. The LK (Link) LED indicates “ready for operation” on that

Using the 6K8-Series (MNS-6K) management software, the user may disable

auto-negotiation and fix the desired operation of each RJ-45 port. User may select 10Mb

when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10 Mb

GarrettCom 6K25 — 2.2.3 Eight-Port Copper Module, 6K8-RJ45 diagram (page 18)
Fig. 4 · 2.2.3 Eight-Port Copper Module, 6K8-RJ45

is a powered-up device at the other end of the cable) in order for a LK LED to provide

or 100Mb speed and full- or half-duplex mode per-port as per user requirement. (See

automatically determine the other side of connection to make the connection, and

valid indications of operating conditions on that port.

Magnum MNS-6K Software Manual for details info.).

2.2.3 Eight-Port Copper Module, 6K8-RJ45

eliminate the need of cross-over cable.

ports. The 10/100Mb switched

way auto-negotiating, and auto-

speed when OFF (when auto-

operation and OFF to indicate

pair cable must be connected

Copper port module, model

ports normally (as a default

setting) are independently N-

negotiation is not disabled).

The FDX/HDX LED is ON

half-duplex mode. A twisted

twisted pair cable.

Show 4 more labels / short text on this page
6K8-RJ45, provides eight · 10/100Mb switched RJ-45 · The 6K25-Series’s 8-port · to indicate full-duplex
Page 19 of the GarrettCom 6K25 user manual — 6KP8-45RJ
Page 19 · click to enlarge
Page 19

802.3af PoE pd devices. The 4-RJ45 POE

except they have capability of providing power on each port to power up the PD devices,

standard. The Power Pass-

totally dependent upon the

Maxm. one PoE modules

A, B or C slot of any 6K s

The PoE modules are also

The New PoE RJ-45 ports act similar to regular RJ-45 ports, except they have

standard. Only 4 x RJ-

mounted 6K-unit. The

option to support four

PoE LED is ON when connected properly to a 803.af compliant PD device on that port.

When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

The PoE (Power-pass-through) RJ-45 ports act similar to regular RJ-45 ports,

per the IEEE802.3af PoE

through PoE modules are

power supply to support

ports. Each port requires

atleast 15watts to power

can be configured in the

with -48vdc power input.

available with mix –n-match with fiber modules. Please check the ordering information

2.2.4 New PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-port

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

2.2.5 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8- port

up the PoE PD devices.

IEEE802.3af PoE

45 (10/100) ports maxm. support

option in one rack

module are also available with mix –n-match with fiber modules. Please check the

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to

capability of providing power on each port to power up the PD devices, per the

ordering information Sec.1.2. for all the various PI6K PoE modules option.

GarrettCom 6K25 — 10/10 LK/AC 1 diagram (page 19)
Fig. 5

10/10 LK/AC 1

3 F/H POE

that is marked as LINK/ACT, as shown in the diagram.

2 1 3 5

10/10 LK/AC

4 FULL/HALF

2 4 6 F/ H POE

8 Port@ 10/100Mb Copper ports

traffic is not affected by PoE.

8 Port@ 10/100Mb Copper ports

6KP8-45RJ

6KP8 -45RJ

LINK LK / ACT 2

Show 10 more labels / short text on this page
powerful -48VDC input · POE(Power Inside) · more RJ-45 (10/100) · power inside PoE · equipped with the · necesasary power · option is factory · configured and · 10/10 · PoE
Page 20 of the GarrettCom 6K25 user manual — ACT
Page 20 · click to enlarge
Page 20

The four RJ-45 ports operate just like the 8-port copper module with auto-cross

On Magnum “4+2” Combo modules, there are four LED’s for each RJ-45 port,

which indicate status the same as described for the 6K8-RJ45 in Section 2.2.3 above. The

2@10Mb fiber mm ST ports, and with

4@ RJ45 10/100 copper and 2@10Mb

PoE LED is ON when connected properly to a 803.af compliant PD device on that port.

When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

2.2.6 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45 and 2@100Mb

four 10/100 switched RJ-45 copper ports and two 100Mb switched multi-mode fiber ST,

(MDIX) feature to eliminate the use of cross-over cable, and the two fiber ports operate

at 100Mbps full-duplex (default). User mode control per port through the MNS software

fiber port’s LEDs indicate status the same way as described for the SFF fiber modules in

4@ MTRJ 100Mb mm SFF fiber and

4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber and the RJ-45 half of

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

The combo six-port modules are combinations of copper and fiber media, available as

SC or single mode SC or Long Reach SC ports. For ports numbering, ports 1,3,5,7 are

The Magnum Combo six-

port modules are also available with

the module is as described for those port types above. For detailed information about

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to

Section 2.2.2 above. Color-coding on the panel of the module shows which LEDs

fiber mm ST ports. The

copper, ports 2 and 6 are fiber, ports 4 and 8 are not present.

10Mb mm ST fiber half of the module, see Section 2.2.5.

that is marked as LINK/ACT, as shown in the diagram.

Sec.1.2 for all the various P6K PoE modules option.

fiber 4@RJ-45 + 2@ 100Mb ST or SC

10/100 LK

F/H ACT

2 6 TX RX TX LK RX LK

1 3 5 7

traffic is not affected by PoE.

belong to which port.

ACT

F/H

is also the same.

ACT

F/H

Page 21 of the GarrettCom 6K25 user manual — TX LK RX
Page 21 · click to enlarge
Page 21

1@ 1000Mb Fiber SC + 2@ 100Mb SC

six-port modules are also available

copper and 2@10Mb fiber mm ST

and the RJ-45 half of the module is as described for those port types above. For detailed

G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber

with 4@ MTRJ 100Mb mm SFF

fiber and 2@10Mb fiber mm ST

ports, and with 4@ RJ45 10/100

media converter or almost any other device with a 10Mb fiber Ethernet port. User mode

control per port through the MNS software is the same as the other 6K25 modules. The

The Magnum 6K25 offered a wide option Gigabit speed with multiple choice

for the modular slot. While up to two Gigabit modules (maxm.) can be configured in the

configuration. The Giga port has been offered

ports. The 4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber

information about 10Mb mm ST fiber half of the module, please check section 2.2.5.

present, ports 3, 4. 7, 8 are not present. The default setup on the 10Mb fiber module is

fiber ports support fiber cabling distances according to the 10BASE-FL standard, i.e.,

modular slot. The Gigabit port option for the modular slot comes in couple of different

as single Gigabit module comes in flavor of

The 4port @10Mb ST fiber modules behave the same as the 8@100Mb ST

half-duplex, which allows the Magnum 6K25 Switch to connect to any 10Mb hub or

fiber modules except for the 10Mb speed. For ports numbering, ports 1, 2, 5, 6 are

2km distance for multi-mode fiber. (Single-mode for up to 10Km distance may be

ports) as shown below .

2.2.7 Four-Port 10 Mb mm Fiber ST Modules

GarrettCom 6K25 — 2.2.7 Four-Port 10 Mb mm Fiber ST Modules diagram (page 21)
Fig. 6 · 2.2.7 Four-Port 10 Mb mm Fiber ST Modules
GarrettCom 6K25 — 2.2.7 Four-Port 10 Mb mm Fiber ST Modules diagram (page 21)
Fig. 7 · 2.2.7 Four-Port 10 Mb mm Fiber ST Modules

2.2.8 Gigabit (1000Mbps) port modules

available as a special order configuration).

TX LK RX

ACT

F/

TX RX LK

TX RX L

ACT

ACT

F/

F/

The Magnum Combo

Page 22 of the GarrettCom 6K25 user manual — TX RX LK
Page 22 · click to enlarge
Page 22

6K25 can do its part to prevent any QOS degradation while it is handling Ethernet traffic

The Magnum 6K25 switching hardware supports the IEEE 802.1p standard and

CRC, i.e., are good packets. This eliminates the propagation of bad packets, enabling all

The 6K25 Modules provide a GBIC opening for insertion of industry-standard

F/ ACT

module on the Gigabit -SX and Gigabit-LX 1@ 1000Mb Fiber SC + 4@10/ 100Mb

There are two LEDs mounted on each Gigabit port module. The Gigabit fiber

users from datagram paths that go all across a network. As a LAN device, the Magnum

packets according to the 802.1p standard. In addition to hardware support for QOS, the

GBICs to provide Gigabit (Gb) media flexibility. GBIC models are available for both

multi-mode (550m) and single-mode (10, 25, 40, 70)km fiber options, and for Gigabit

fulfills its role in support of QOS, giving packet processing priority to priority tagged

Magnum 6K25’s are store-and-forward switches. Each frame (or packet) is

10/100 L

port is by default configured at AUTO mode, and can be fix at 1000Mbps speed full-

Quality of Service means providing consistent predictable data delivery to

MNS software (R2) supports two priority queues that can be shared across the eight

levels of defined packet priorities for application-specific priority control by the user

technique ensures that all forwarded frames are of a valid length and have the correct

1 3 5 7

loaded into the Switch’s memory and inspected before forwarding can occur. This

duplex mode at any times and has LEDs that indicate LK (Link status) and ACT

copper as well, with new models appearing often.

transceivers are compatible with the IEEE 802.3z Gigabit standards.

TX RX LK

ACT

F/

2.2.9 Packet Prioritization, 802.1p QOS

2.2.10 Frame Buffering and Flow Control

modules on the Magnum 6K25s are normally

performance. The 1000Mbps SC fiber-optic

The 1000Mb Gigabit fiber-port

(receiving activity) on that port when lit.

set (factory default) to operate at AUTO

through software configuration settings.

mode for best fiber distance and

through its ports and buffers.

Page 23 of the GarrettCom 6K25 user manual — GarrettCom proprietary MIBs for SNMP-
Page 23 · click to enlarge
Page 23

When the Magnum 6K25 Switch detects that its free buffer queue space is low,

2.2.11 Managed Network Software ( MNS-6K ) for Magnum 6K25-Series

Series MNS Software User guide in pdf format, a separate document normally accessed

All MNS-6K software information, including new releases and upgrades related to MNS-

"express") impose minimal frame latency, they will also permit bad frames to propagate

out to the Ethernet segments connected. The "cut-through" technique permits collision

fragment frames (which are a result of late collisions) to be forwarded which add to the

network traffic. Since there is no way to filter frames with a bad CRC (the entire frame

collisions and bad packets are more likely when traffic is heavy, the result of store-and-

forward operation is that more bandwidth is available for good packets when the traffic

the Switch sends industry standard (full-duplex only) PAUSE packets out to the devices

stop sending traffic, which allows a traffic catch-up to occur without dropping packets.

sending packets to cause “flow control”. This tells the sending devices to temporarily

control mechanism (when operating at half-duplex only). When the Switch detects that

which allows to configure the Magnum 6Ks as a Managed Switch and other Software

its free buffer queue space is low, the Switch prevents more frames from entering by

forcing a collision signal on all receiving half-duplex ports in order to stop incoming

Magnum 6K25-Series’s come with licensed MNS-6K Firmware (Rel 3.2),

enabled features. For additional information about MNS-6K, see the Magnum 6K25-

must be present in order for CRC to be calculated), the result of indiscriminate cut-

through forwarding is greater traffic congestion, especially at peak activity. Since

Then, normal packet buffering and processing resumes. This flow-control sequence

Another feature implemented in Magnum 6K25 Switches is a collision-based flow-

While other switching technologies (such as "cut-through" or

Alternatively, for documentation and latest information, or needed

6K software, can be accessed and download from GarrettCom’s FTP site.

occurs in a small fraction of a second and is transparent to an observer.

of the available bandwidth to be used for valid information.

via your web-browser, at ftp://ftp.garrettcom.com/

or FTP client program by ftp.GarrettCom.com using

GarrettCom proprietary MIBs for SNMP-

passwordm6kuser
userm6kuser

load is greatest.

traffic.

Page 24 of the GarrettCom 6K25 user manual — 2.2.11 Managed Network Software ( MNS-6K ) for Magnum 6K25-Series
Page 24 · click to enlarge
Page 24

www.GarrettCom.com/techsupport/index.htm#software and look for Magnum

Magnum 6K25 Switches provide non-blocking (all ports can run at full speed at once)

Gigabit ports for backbone connections, where managed network services are desired.

Magnum 6K25 Managed Fiber Switches are designed to naturally include fiber ports,

The 1U Magnum 6K25 chassis has 4 slots for port configurations. Family of 4, 6 or 8

port modules allow the user to select the desired mix of port types & speeds. The port

The standard rack mounting provides Ethernet ports and status LEDs in front, service

applications, models with –48VDC or 24VDC or 125VDC are available. Dual Source

„ Heavy-duty design for Industrial Ethernet and extended temperature operation.

Fiber ports take more power than copper ports, but the Magnum 6K25 design provides

performance with standard Managed Networks Software (MNS-6K) included. They

priority to priority tagged packets according to the IEEE 802.1p standard. For port-

and application-specific priorities, the QoS software may be configured by the user.

for this with heavy-duty components. The ambient temperature can be up to 55°C.

allow the basic and advanced info about the Magnum MNS-6K management software

„ Modular design for port flexibility, in a 1U space-saving rack-mount package

modules are normally factory installed and tested, but may be changed in the field.

Standard 19’ rack mount brackets are included, with ETSI and 23” Telco optional.

Standard AC power input is IEC plug, auto-ranging for worldwide use. For special

Magnum MNS-6K Operator Training – This interactive training software

are typically used in LAN traffic centers with 16 to 24 100Mb ports and one or 2

The Magnum 6K25 switching hardware supports QoS, giving packet processing

and support mixes of multi-mode and single-mode; 10 Mb, 100Mb and 1000Mb

„ Rack-mounting may be standard or “reverse”, 19 inch or ETSI or 23” Telco

„ Standard AC power input, -48VDC or 24VDC or 125VDC input is optional

connectors. RJ-45 10/100 ports can also be configured in the mix of port types.

connections (power input and management console) in the rear. “Reverse” rack

mounting provides status LEDs in front and all cabling connections in the rear.

speed; full-and half-duplex; classic Small Form Factor (SFF) and GBIC fiber

DC input can also be selected and configured on the DC power input models.

„ Switching services includes 802.1p QoS packet prioritization

„ Managed switching for high performance Ethernet LANs

or email: support@GarrettCom.com for further information.

2.3 Features and Benefits

and a useful tool for first time user.

MNS-6K info..

„ Features Fiber-Built-In

Page 25 of the GarrettCom 6K25 user manual — 2.2.11 Managed Network Software ( MNS-6K ) for Magnum 6K25-Series
Page 25 · click to enlarge
Page 25

cross-over cable. The Auto-MDIX capability allow the Magnum 6K25 to cascade any

The RJ-45 modules are equipped with MDI/MDIX capability to eliminate the use of

The 6K25 has been tested and certified for NEBS and ETSI. Request test reports.

„ MNS-6K licensed Network Management Software included, S-Ring optional

Release 2.3 (summer ’03) includes SNMP Switch Management with secure access

control, RMON, CLI, Port Security; Port Mirroring; Port Settings Control; Telnet,

TFTP, FTP support, Spanning Tree Protocol, RSTP, Web-based, multi-level QoS,

Port- and tag-based VLANs, GVRP, IGMP Snooping, SNMPc GUI support; Event

Log; SNTP client for time-of-day; BootP and DHCP client for IP configuring, and

password security. Supplied and updated via Internet and GCI FTP Server.

Hub, switches or media converters with normal straight cable.

„ RJ-45 ports are MDI/MDIX supported

„ NEBS and ETSI tested and certified

Page 26 of the GarrettCom 6K25 user manual — 2.4 Applications
Page 26 · click to enlarge
Page 26

traffic centers require Gb backbone services. The performance characteristic of the 6K25

Ethernet network center. A secure VLAN-enabled network is simply an administratively

R&D, and Marketing need to keep a secure LAN, the 6K25’s VLAN feature will prevent

Magnum 6K25 Fiber Switches offer high performance and modularity. They

provide the flexibility of 100Mbps fiber and copper ports as well as Gigabit ports, with

industry-standard LAN management software. Magnum 6K25 Switches are easily used

Switches enables them to inter-connect a series of subnets (one subnet per 6K25 Switch

nodes are in which broadcast domains by setting membership profiles for each of them.

Full-duplex future proof fiber media can easily connect long distance subnets

in a variety of applications including MANs (metropolitan area networks) client/server

computing, secure VLAN- performance upgrades to departmental networks, and LAN

port) in a LAN traffic center. The subnet connections may be via fiber or twisted pair

Equipped with lots of useful features, the Magnum 6K25 Managed switch is

configured broadcast domain. The network administrator determines which ports and

controlled. The Managed Magnum 6K25 equipped with VLANs capability is ideal for

choice for use in applications with LAN connections to an organization’s multiple site

supported by the Magnum 6K25 Switch. A main NT-server in a secure area protected

from earthquake or fire hazards can be connected to the full duplex Gigabit Fiber port.

The Magnum 6K25’s VLAN capability can be developed in several types of Virtual

In an office environment where departments such as Finance, Engineering,

traffic cross-over among domains, and thus from keep sensitive data and information

The mixed-media capability is ideal for upgrading existing Ethernet LAN

networks where existing cabling must be accommodated. The fiber-built-in media

capability is ideal for integrating future-proof fiber cabling into the LAN structure.

The modularity of the 6K25 Managed Fiber Switch makes it an attractive

offices. The different offices can be easily connected together with the Fiber ports

able to handle a VLAN application and provide a security and performance in an

any application where a secure VLAN to multiple departments is needed.

cabling, 100Mbps or 10 Mbps speed, and full-or half-duplex mode.

Example 1Magnum 6K25 Switch for a VLAN application

LANs, such as Port-based VLANs, or Tag-based VLANs.

2.4 Applications

Page 27 of the GarrettCom 6K25 user manual — 2.4 Applications
Page 27 · click to enlarge
Page 27

capability of the Magnum 6K25 Switch helps create a database of all the network subnets

backbone for a diversified network with multiple subnets. The back bone consists of high

bandwidth Gigabit-enabled data-mining server for the vital database located in a separate

user-configurable Magnum 6K25 provides an extra boost to the network requirements by

The 6K25 Managed Fiber Switch with mixed-media flexibility allows the users

secured building. The copper ports are required for multiple subnets inside the building.

The entire spread network will be manageable to provide easy, detectable, uninterrupted

Example 2. In another application, a managed switch is needed to provide an Ethernet

provide secure long distance LAN connections. The entire network is sharing a higher

The Magnum 6K25 Managed Fiber Switch equipped with the mix of copper

and fiber ports provides an economical and seamless solution to the requirements. The

1000Mb. The user can utilize the SNMP feature equipped with VLAN, RMON, SNTP

speed LAN segments supported by 100Mbps full-duplex future-proof fiber media to

providing copper/fiber media along with the higher bandwidth support of 10/100 and

support future expansion as the network evolves. The Gigabit port option boosts the

and other standard managed LAN features to provide a secure and stable network.

more than one configuration alternative. The user has an advantage by fulfilling the

present requirements as well as benefiting from the multiple choices of modules to

and provide a stable secure network to all applications. The SNMP management

bandwidth for high speed to support the peak traffic and minimize congestion.

support through a viewable SNMP monitor.

to easily manage the network.

Page 28 of the GarrettCom 6K25 user manual — 3.0 Installation
Page 28 · click to enlarge
Page 28

1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment

2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate airflow must be maintained for proper and

3.) If the equipment is mounted in an enclosed or multiple rack system, placement of the equipment must not overload or load

4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent

The location of a Magnum 6K25 Switch is dependent on the physical layout of

compact size allows it to be easily placed in an office or lab area, and it can also be either

GarrettCom 6K25 — 3.1 Locating Magnum 6K25 Switches diagram (page 28)
Fig. 8 · 3.1 Locating Magnum 6K25 Switches

5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and

7.) CB-Circuit breakers of 10Amps should be shown on top of the Rack.

the network. Typically the Switch is placed in a central wiring location where groups of

because they have rubber feet they can also be installed on a shelf or table top unit. The

This section describes installation of the Magnum 6K25 Switches, as well as

network devices need to be connected in order to communicate with each other. These

Before installing the equipment, it is necessary to take the

6.) 24vdc, -48vdc, and 125vdc must be installed in restricted access locations.

Switches are typically rack mounted in a wiring closet see Section 3.3.2 below), but

Figure 3.1Location of the Magnum 6K25’s cooling fans

overloading of the building/s electrical circuits.

Locate an AC receptacle that is within six feet

monitor the status LEDs. Keep an open area around the

left side, while the unit is in operation. See figure below.

rugged metal case of the Magnum 6K25 will normally

protect it from accidental damage in a lab or workplace

setting. Maintain an open view of the front to visually

unit so that cooling can occur from the small fan on the

(2 meters) of the intended Magnum 6K25 site. The

must be less than or equal to 500C.

3.1 Locating Magnum 6K25 Switches

shelf of wall-mounted (see Section 3.3.1 below).

connection of the various Ethernet media types.

uncompromised earthing path.

unevenly the rack system.

following precautions:

3.0 Installation

safe operation.

Page 29 of the GarrettCom 6K25 user manual — Copper:
Page 29 · click to enlarge
Page 29

individually selected and configured per-port. See Section 2.4 for a description

10BASE-T and 100BASE-TX twisted pair 100m (328 ft) 6K8-RJ45

connectors. This procedure applies to ports using a 6K25 module, MST-type port.

2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue

The Magnum 6K25 Switches are specifically designed to support all

1. Before connecting the fiber optic cable, remove the protective dust caps from the

dampened in alcohol. Make certain the connectors are clean before connecting.

connection has been established at both ends (and when power is ON in

The following procedure applies to installations using a PM with ST-type fiber

3. Connect the Transmit (TX) port (light colored post) on the Magnum PM to the

Receive (RX) port of the remote device. Begin with the color-coded strand of

(TX) port of the remote device. Use the non-color coded fiber strand for this.

5. The LINK LED on the front of the PM will illuminate when a proper

improper cable polarity. Swap the fiber cables at the PM connector to

The various media types supported along with the corresponding IEEE

4. Connect the Receive (RX) port (dark colored post on the PM) to the Transmit

the unit). If LINK is not lit after cable connection, the normal cause is

accomplished by using a family of different port Modules which can be

small form factor mm1 Fiber 2.0km (6,562 ft) 6K8-MTRJ, -MLC small form factor sgl.m1 Fiber 15 km 6KP8- SLC

bands at regular intervals; you must use the color-coded strand on the

IEEE Standard Media Type Max. Distance Port Module

100BASE-FX mm1 Fiber 2.0km (6,562 ft) 6K6-MSC, -MST

standard Ethernet media types within a single Switch unit. This is

sgl.m2 Fiber 5Km GBIC-LXSC

1 mm = multi-mode 2 sgl.m = single-mode 3.2.1 Connecting Fiber Optic ST-type, “twist-lock”

sgl.m2 Fiber 18.0km (95K ft) SSC, SSCL

802.3 and 802.3u standards and connector types are as follows:

100BASE-FX mm1 Fiber 220m ( ft) GBIC-SXSC

associated ports at each end of the fiber optic segment.

the cable for this first TX-to-RX connection.

3.2 Connecting Ethernet Media

remedy this situation.

of the PMs.

Copper:

Fiber:

Page 30 of the GarrettCom 6K25 user manual — 3.2.3 Connecting Single-Mode Fiber Optic
Page 30 · click to enlarge
Page 30

The following procedure applies to installations using a PM with SC-type fiber

(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx

fiber allows full bandwidth at longer distances, and may be used to connect 10 Mb nodes

media types100BASE-TX and 10BASE-T. CAT 5 cables should be used when making

mixed-speed network, since dual-speed ports are auto-sensing for either 10 and

1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is
2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is

connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable

The RJ-45 ports of the Magnum 6K25 can be connected to the following two

100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100

The following procedure describes how to connect a 10BASE-T or 100BASE-

are the diameters of the core and the core plus the cladding respectively). Single-mode

3.2.4 Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or Shielded)

Twisted Pair (CAT 3, 4, 5) 10BASE-T RJ-45

TX twisted pair segment to the RJ-45 port. The procedure is the same for both

When connecting fiber media to SC connectors, simply snap on the two square male

When using single-mode fiber cable, be sure to use single-mode fiber port

The same procedures as for multi-mode fiber applies to single-mode fiber

Twisted Pair (CAT 5) 100BASE-TX RJ-45

and 100Mb) be used whenever possible in order to provide flexibility in a

Media IEEE Standard Connector

shielded, either unshielded or shielded cables and wiring may be used.

connectors into the SC female jacks of the 6KPM until it clicks and secures.

3.2.2 Connecting Fiber Optic SC-type, "Snap-In"

connectors. Follow the steps listed in Section 3.2.2 above.

connectors, i.e., using 6K-MSC, 6K-SSC single-mode.

3.2.3 Connecting Single-Mode Fiber Optic

unshielded and shielded twisted pair cables.

up to 10 Km apart, or 18Km with the 6K-SSC.

100Mb/s.

meters (328 ft).

established

Page 31 of the GarrettCom 6K25 user manual — GARRETT
Page 31 · click to enlarge
Page 31
GarrettCom 6K25 — 1 3 5 7 10/100 LK diagram (page 31)
Fig. 9

could produce kigh (greater than 2500V ) levels of ground potential rise (GPR)

during line-to-ground fault conditions. The 6K25 passes the 1613specifications

either case, the maximum distance for unshielded twisted pair cabling is 100 meters (328

Mb and 1000Mb) be used whenever possible in order to provide flexibility in a

The Magnum 6K25 Manageable Switches can be easily mounted on a table-top

for zero packet loss with fiber ports & with RJ45 ports used as indicated here.

The RJ-45 Gigabit ports of the Magnum 6K25 can be connected to the media

The following procedure describes how to connect a 1000BASE-T twisted pair segment

1. 1000Base-T connections require that all four pairs or wires be connected. Insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port.
2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established

telecommunication multiplexers installed in close proximity (i.e., less than 2

types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)

balanced cable is recommended to use when making 1000BASE-TX connections. In

to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted

or any suitable horizontal surface, and has four rubber feet to provide stability without

substation applications to interface to field devices across distances which

balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)

advises that, for substation applications, the RJ-45 ports are intended for

3.2.5 Connecting Twisted Pair (CAT5E or better, Unshielded or Shielded)

meters or 6.5ft) to the 6K25. It is not recommended to use these ports in

ft). See Section 4.3 for manual Up-Link switch on port 1 of copper port modules.

Media IEEE Standard Connector

connectivity to other communication equipment such as routers or

Twisted Pair (CAT 5E) 1000BASE-T RJ-45

1 3 5 7 10/100 LK

10/100 LK 2 4 6 8 F/ H ACT

F/H ACT

1 3 5 7

10/100 LK

F/H ACT

2 6 TX RX TX LK RX LK

F/H ACT

F/H

ACT

Magnum 6K25 1 3 5 7 10/100 LK

10/100 LK 2 4 6 8 F/ H ACT

F/H ACT

3.3 Table-Top or Shelf Mounting

cables and wiring may be used.

mixed-speed network.

GARRETT

pair cables.

surfaces.

Show 6 more labels / short text on this page
Magnum QS5116 · Magnum QS5116 PWR · Managed Fiber · Fiber Switch · Switch · scratching finished
Page 32 of the GarrettCom 6K25 user manual — 10/100 L 2 4 6 8 F/ H AC
Page 32 · click to enlarge
Page 32

3.3.1 Rack-mounting (for 19” RETMA racks), regular Magnum 6K25s Installation of a Magnum 6K25 Fiber Switch in a 19” rack is a simple

mounting purposes. The 23” and the ETSI brackets are mainly used for larger equipment

mounted in various ways. The same holes fit all three types (19”, ETSI, 23”) of brackets.

attached flush with the front, or attached in the center for a set-back mounting which may

The optional 23” brackets and the ETSI (21”) brackets each come as a pair in a

LED status indicators should be in plain view and easy to read. Rack-mount installation

6K25 unit). These brackets attach to the front sides of the Switch (regular package, i.e., not the Reverse version), which is then typically fastened into a standard 19” RETMA

also available (optional) for rack-mounting of Magnum 6K25 Switches. These brackets

The bracket mounting holes in the sides of the Magnum 6K25 permits it to be

procedure. The units are 1U (1.70”) high. When properly installed, the front-mounted

The 23” brackets and the ETSI (European metric, approx. 21”) brackets are

package, along with the necessary screws for attaching the brackets to the sides of the

requires special 19” rack-mounted brackets and screws (included with each Magnum

are popular in the Telco industry where they are a standard for Central Office rack-

The mounting for the 23” is illustrated in Figure 3.3.1 below. The brackets may be

assemblies in rack-mounting frames where the rack-mount equipment is typically

Fig 3.3.1 Mountings for Magnum 6K25 units rack-mounted in a frame

GarrettCom 6K25 — 10/100 L 2 4 6 8 F/ H AC diagram (page 32)
Fig. 10

Magnum Switch unit. They must be ordered as line items.

10/100 L 2 4 6 8 F/ H AC

10/100 L 2 4 6 8 F/ H AC

10/100 L 2 4 6 8 F/ H AC

10/100 L 2 4 6 8 F/ H AC

accessed in operation from both sides.

10/100 L 2 4 6 8 F/ H AC

10/100 L 2 4 6 8 F/ H AC

10/100 L 2 4 6 8 F/ H AC

10/100 L 2 4 6 8 F/ H AC

reduce cabling torque.

rack as shown here.

Show 4 more labels / short text on this page
Mid-Range Mount or · 23” Mount Bracket · 5” Set-Back Bracket · Standard Flush
Page 33 of the GarrettCom 6K25 user manual — 10/100 L 2 4 6 8 F/ H AC
Page 33 · click to enlarge
Page 33

With each bracket type, there are three different mounting options is shown in

Fig. 3.3.2. The case of the Magnum 6K25 has mounting holes prepared for each of the

mounting arrangements. Users may choose the mounting arrangement most suitable for

3.3.2 Rack-mounting, Reverse version of the Magnum 6K25s The optional Reverse Magnum 6K25 Model has all of the cabling (Ethernet

cabling, power cabling and console port cabling) connectors in the rear, and the status

LEDs in the front. The status LEDs that are co-incident with the ports are still present

there, and a second or dual set of LEDs are used for status visibility in the front of the

frame or the 23” frame or ETSI (21”) frame. The 19” brackets are included with each

The Magnum 6K25 Switches incorporate an internal universal power supply

manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard power

The auto-ranging power supply supports installation environments where the

There are three options of brackets available to mount in the standard 19”

and have a recessed male IEC connector for the AC power cord at the left-rear. A

cord is supplied with each unit shipped within the United States and Canada.

Fig 3.3.2 Reverse Magnum 6K25 units, rack-mounted in a frame

3.4 Powering the Magnum Managed Fiber Switch

GarrettCom 6K25 — 10/100 L 2 4 6 8 F/ H AC diagram (page 33)
Fig. 11

unit, the other two may be purchased if desired.

unit, showing the same data.

their installation.

Show 5 more labels / short text on this page
Mid-Range Mount or · 5” Set-Back Bracket · Rear Mount Bracket · Mount Bracket · Standard Flush
Page 34 of the GarrettCom 6K25 user manual — 3.5 6K25 Port Module (6KPM) Installation
Page 34 · click to enlarge
Page 34

AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz.

connected or disconnected without concern for AC power-related problems or damage to

3.4.1 Alarm Contacts for monitoring internal power, and Software Traps The Alarm Contacts feature, optional on Magnum 6K25’s, provides two

The AC or DC power input connection is in the same panel. A manual On-Off Switch for

power to the unit is not available on 6K25 units with the Alarm Contacts option, as these

enabled, the Form C Normally Closed (NC) contact is held close during normal software

The second (bottom position) NC Alarm Contact is held close when there is

power on the main board inside of the 6K25. This provides a “Hardware Alarm” because

1. There is four terminal block (1,2,3,4)provided next to AC/DC power supply 2. The top two pins (1,2) are software operated 3. The bottom two pins (3,4) are hardware operated 4. By default it is NC (normally closed) 5. The software operation need to be enable and set to get the Alarm traps. For detail information about the Software Alarm and software control of SNMP alarm traps, please

The 25-port units will consume over 20 watts of power typically. When connecting the

The first NC Alarm Contact (top position) is a “Software Alarm”, operated

feature with a software configuration command if desired. When the Software Alarm is

Ethernet cabling, there is no need to power down the unit. Individual segments can be

Power supply options are available to suit the 6K25 Switches to special high-

See the Appendices of this manual for more details. Use an RFQ for other variations.

Form C Normally Closed (NC) contacts to which the user can attach two sets of status

monitoring wires at the green terminal block. When this option is present, the terminal

operation. A user-defined software malfunction, such as an SNMP Trap or a Software

The Magnum 6K25 Switches are normally received from the factory with all

block for Alarm Contacts is part of the Power Input panel in the Magnum 6K25 case.

Security violation or an S-Ring Fault, causes the contact to open and thus trigger an

the NC contacts will open when internal power is lost, either from an external power

availability communications and/or heavy industrial-grade applications, including:

by user settings in the MNS-6K software. The user can disable the Software Alarm

down condition or by the failure of the power supply inside of the Magnum 6K25

reference the Magnum MNS-6K Software User Manual. (Chapter 19th).

* -48VDC, 24VDC and 125VDC with dual-source DC input,

* -48VDC, 24VDC and 125VDC with single DC input,

3.5 6K25 Port Module (6KPM) Installation

two features occupy the same space in the case.

Switch. Useful info. about Alarm contacts:

alarm in the user’s monitoring system

the unit.

Page 35 of the GarrettCom 6K25 user manual — STOP!!!
Page 35 · click to enlarge
Page 35

contains (Daughterboard (Bigger) and Granddaughter board (smaller), three 5/8

for an available front-mounted slot must be removed. The following procedure describes

Front panel face plate package. The Front panel faceplate package includes 3

mixed with other Fiber combo 6KPM card packages. Always install the PM

assembled together with the help of 22 Philips-head screws. There are 7 screws located

on the front-bottom and rear-top of the unit and four screws each on the sides. Remove

these screws. Once these are removed, the top cover is easily lifted off the chassis base.

required 6KPM modules installed. There may be situations where 6KPM cards need to

be added or replaced. In cases where additional 6KPM cards are needed, the faceplate

1. Make sure the 6KPM Card package has all necessary accessories to install it

properly. Each 6KPM Card package except the Gigabit, for field installation

stand offs for Granddaughter board, six #4-40 Pan-Head screws along with

Granddaughter board. The copper 6KPM card should not work properly if

The Magnum 6K25 chassis are combined with top and bottom parts and

equipment) are sensitive to static discharge. Use proper ESD measures when

When the chassis top cover has been removed, the interior of the unit is exposed.

Failure to do so may result in damage to the unit

from the chassis before attempting to remove

for all powers single or dual, is unplugged

Be sure the power cord and connections

3.5.1 Preparation for Installing and Removing 6KPMs

and/or replace any PM cards.

module separately one by one to avoid the mixing.

and will void the warranty.

retainer brackets and six #2-56 flat head screws.

STOP!!!

Figure 3.5.1aRemoving Chassis Cover
2. Remove Chassis Cover

handling port modules.

this operation.

Page 36 of the GarrettCom 6K25 user manual — 3.5.2 Installing 6KPM Cards in the Magnum 6K25
Page 36 · click to enlarge
Page 36

Looking down into the Magnum 6K25 unit, notice that there are individual PM

installation spaces and female latch(white) connectors provided on the main board along

position, but unscrew only four of the screws as shown in Fig. below. These screws are

Up to four front-mounted 6KPM cards may be installed in one Magnum 6K25

Looking into the vertical placed Chassis cover of the unit, there are three brackets with

also used to secure the individual 6KPM cards screen plate which can be subjected to

retaining screws (#256 flat head ) which hold each PM Face plate card slot securely.

There are four PM slots (A, B, C and D) located on the front of the chassis cover.

These six screws shown in the picture below are used to secure a PM face plate in

GarrettCom 6K25 — 3.5.2 Installing 6KPM Cards in the Magnum 6K25 diagram (page 36)
Fig. 12 · 3.5.2 Installing 6KPM Cards in the Magnum 6K25
GarrettCom 6K25 — 3.5.2 Installing 6KPM Cards in the Magnum 6K25 diagram (page 36)
Fig. 13 · 3.5.2 Installing 6KPM Cards in the Magnum 6K25
Figure 3.5.1bMagnum 6k25, Top view without chassis cover

Managed Fiber Switch unit. Follow these steps to install a 6KPM.

1. Remove top chassis cover. See procedure in Section 3.5.1 above.

with four stand-off’s for each 6KPM card position. (See Figure 3.5.1b).

Figure 3.5.1cTop View – 6KPM retaining screws hold Face Plate

3.5.2 Installing 6KPM Cards in the Magnum 6K25

significant forces from the attached cables. (See Figure 3.5.1c)

3. Remove front panel face plate retaining screws
Page 37 of the GarrettCom 6K25 user manual — 3.5.2 Installing 6KPM Cards in the Magnum 6K25
Page 37 · click to enlarge
Page 37
GarrettCom 6K25 — 3.5.2 Installing 6KPM Cards in the Magnum 6K25 diagram (page 37)
Fig. 14 · 3.5.2 Installing 6KPM Cards in the Magnum 6K25
2. Placed Granddaughter board (as shown in fig. 3.5.2a and 3.5.2b) on the chassis

Fig 3.5.2b Granddaughter Board placed in slot

copper 10/100 ports. Port# 1

Can be configured as uplink

(x) crossed ports for

built in stand off (female) provided at the front of the 6K25 Main Board and

Granddaughter board The 5/16 stand off has been used to place the daughter

Fig. 3.5.2c Daughter Board,

A and secured with three 7/16 stand-off’s

3. The figure here illustrates the basic layout of an individual PM card. Each

screw down tightly with the three 5/16 stand-off (male) on the top of the

top view of version for 4

board on the top of the granddaughter board and latch it securely.

as shown in the Fig.

6KPM card fits into the space provided on the main board.

GarrettCom 6K25 — 3.5.2 Installing 6KPM Cards in the Magnum 6K25 diagram (page 37)
Fig. 15 · 3.5.2 Installing 6KPM Cards in the Magnum 6K25
GarrettCom 6K25 — 3.5.2 Installing 6KPM Cards in the Magnum 6K25 diagram (page 37)
Fig. 16 · 3.5.2 Installing 6KPM Cards in the Magnum 6K25

Fig 3.5.2a Granddaughter Board

cascading · shown separately · Uplink

Page 38 of the GarrettCom 6K25 user manual — 3.5.2 Installing 6KPM Cards in the Magnum 6K25
Page 38 · click to enlarge
Page 38
GarrettCom 6K25 — 3.5.2 Installing 6KPM Cards in the Magnum 6K25 diagram (page 38)
Fig. 17 · 3.5.2 Installing 6KPM Cards in the Magnum 6K25
GarrettCom 6K25 — 3.5.2 Installing 6KPM Cards in the Magnum 6K25 diagram (page 38)
Fig. 18 · 3.5.2 Installing 6KPM Cards in the Magnum 6K25
4. Hold the daughter board with both hands at the end and align the two cream

Fig 3.5.2d Daughter

Fig. 3.5.2e Magnum 6KPM daughter board aligned with the bottom

Figure 3.5.2fSecurely latching up 6KPM Cards into a Magnum 6K25

Board shown upside down with two male latch connectors

GarrettCom 6K25 — 3.5.2 Installing 6KPM Cards in the Magnum 6K25 diagram (page 38)
Fig. 19 · 3.5.2 Installing 6KPM Cards in the Magnum 6K25

female connector for the installation

slowly and firmly with two

properly and the mounting

fingers (as shown below in

Fig. 3.5.2f) on the top of

placed at the bottom of

the daughter board with

connector placed on the

main board. As shown

below in Fig. 3.5.2e

holes are aligned with

stand offs then press

latched up securely.

5. Once the latching
Show 7 more labels / short text on this page
connectors are aligned · the latching connectors · Granddaughter and · until the connectors · connectors (male) · the other female · color latching
Page 39 of the GarrettCom 6K25 user manual — screen plates installed inside the chassis cover using brackets and screws
Page 39 · click to enlarge
Page 39
Fig. 3.5.2g Top View6KPM Module installed inside a 6K25

operational. When leaving 6KPM slots empty, always use a face plate (Magnum 6K8-

BLNK) to cover the slot opening in the front panel. This will maintain proper cooling

GarrettCom 6K25 — screen plates installed inside the chassis cover using brackets and screws diagram (page 39)
Fig. 20 · screen plates installed inside the chassis cover usi…
7. Once the installation of granddaughter and daughter modules is done, the front
GarrettCom 6K25 — screen plates installed inside the chassis cover using brackets and screws diagram (page 39)
Fig. 21 · screen plates installed inside the chassis cover usi…

complete the installation process for that port module. The front panel screen

Fig. 3.5.2h Inside view of chassis cover (from the rear), showing the front panel

brackets and 6 #256 flat head screws. The brackets and screws have been

8. Once all 6KPM cards have been installed (including faceplates for empty

slots), the chassis cover should be replaced. Make sure the chassis cover is

panel screen plates need to be placed on the front of the chassis cover to

plate comes along with the package of port module separately along with

air flow, safety, and operation as required by FCC, CE, and other regulations.

screen plates installed inside the chassis cover using brackets and screws

installed inside of the top cover as shown in Fig. 3.5.2h.

aligned properly before securing the enclosure.

below shows the top view

holds the daughter board

daughter board with 6

#440 screws, so that it

6KPM cards inside the

6. Now screw down the

securely. The figure

of 6KPM card after

Magnum 6K25.

successfully installing the

Page 40 of the GarrettCom 6K25 user manual — screen plates installed inside the chassis cover using brackets and screws
Page 40 · click to enlarge
Page 40
GarrettCom 6K25 — screen plates installed inside the chassis cover using brackets and screws diagram (page 40)
Fig. 22 · screen plates installed inside the chassis cover usi…
GarrettCom 6K25 — screen plates installed inside the chassis cover using brackets and screws diagram (page 40)
Fig. 23 · screen plates installed inside the chassis cover usi…

COTX require four bracket extender for each(slot A, B, or C COTX). Attach the bracket

from the PCA to the center standoff on the main mother board. The bracket provide

To properly remove a 6KPM card from the 6K25 Managed Fiber Switch,

2. Remove retaining screws placed on top for the 6KPM and Face Plate

that has been removed, follow the steps as described for installing a 6KPM card

firmly. Figure 3.5.3aTop View - 6 retaining s crews shown by arrows
1. Remove chassis cover See procedures in Section 3.5.1 above.

checking the speed, F/H, and activity status)

the chassis. The screen faceplate screws out from

the inside front of the chassis cover by loosening

On the top of the daughter module there are six

standoffs holding the Granddaughter board with

the 4 screws and bracket while holding it down

position (see Figure 3.5.3a). Remove the three

a 6KPM-BLNK face plate cover.

retaining screws for each 6KPM card. These

screws are used to secure a 6KPM card in

the board near the latch-up connectors as

slot is to remain unused, be sure to install

If another 6KPM card is replacing the one

out the daughter board from the latching

connectors, using both hands, gripping

shown in Fig. 3.5.3b . If the now empty

the stability to the Gigabit module.

3.5.3 Removing 6KPM Cards

follow the 3 steps below.

Carefully and gently pull

Figure 3.5.3bRemoving a 6KPM
3. Remove 6KPM Card

discussed in Section 3.5.1.

Card

Page 41 of the GarrettCom 6K25 user manual — Console (DB-9) Por t
Page 41 · click to enlarge
Page 41

3.6 Connecting the Console Terminal to Magnum 6K25 (Management)

(the RS-232 port on the 6K25 Switch) to the your PC, so that your PC becomes

Rear View of Magnum 6K25, (Typical Console Port is on the Rear of Reverse 6K25

Software Manual available on GarrettCom‘s FTP site. Detail info. about the MNS is

Use a DB-9 “null modem” cable to connect the Magnum6K25 Console Port

6K25 Switch configuration for Network Management, please refer to Magnum 6K25

3.6.1 RS-232 (DB-9) Console Com port (Serial port) pin assignments.

1 CD Carrier detect (not used)

3 TXD Transmit Data (output)

Pin Signal Description

2 RXD Receive Data (input)

O

OF

5 GND Signal Ground

4 open not used

6-9 open not used

Pin 5 Pin 1

available on 2.2.9 ( see page no. 13) of this manual.

DB-9 (Console port connector)

the 6K25’s Console Terminal.

Console (DB-9) Por t

CONSOLE

PORT

Models)

Page 42 of the GarrettCom 6K25 user manual — 4.0 OPERATION
Page 42 · click to enlarge
Page 42

intended for temporary connectivity to other equipment such as PCs. Since the

Each time a packet arrives on one of the switched ports, the decision is taken to

either filter or to forward the packet. Packets whose source and destination addresses are

on the same port segment will be filtered, constraining them to that one port and relieving

is on another port segment will be forwarded to the appropriate port, and will not be sent

The Magnum 6K25 Switches operate in the store-and-forward switching mode,

which eliminates bad packets and enables peak performance to be achieved when there is

terminal) to connect directly to the switch using a straight through cable.(Note:

among all of its ports. The Magnum 6K25 supports10/100Mbs for copper media and 10

or 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and

network performance. All ports can communicate to all other ports in a Magnum 6K25,

100Mbps selection for the switched ports must be configured through MNS software per

the rest of the network from having to process them. A packet whose destination address

to the other ports where it is not needed. Traffic needed for maintaining the operation of

The above provided information enables a managed station( a PC or Console

The Null-Modem (DB-9) cable is optional and can be order from the factory,

console port connection is temporary, it is excluded from IEEE 1613 packet-

configuring necessary to be done for basic operation at installation or for maintenance.

(resides inside the unit) on the 6K8-RJ45. Optional Half / Full duplex mode and 10 or

advises that, for substation applications, the serial RJ-45console ports are

This chapter describes the functions and operation of the Magnum 6K25

A Magnum 6K25 provides switched connectivity at Ethernet wire-speed

but local traffic on a port will not consume any of the bandwidth on any other port.

The only hardware configuration settings are user options for an UP-LINK Switch

Magnum 6K25 units are plug-and-play devices. There is no software

unit as per the requirement. The internal functions of both are described below.

the network (such as occasional multi-cast packets) are forwarded to all ports.

loss testing per the 1613 standard-defined test procedure.

4.1 Switching Functionality

heavy traffic on the network.

4.0 OPERATION

along with the unit

Switch.

Filtering and Forwarding

Page 43 of the GarrettCom 6K25 user manual — 4.2 Status LEDs
Page 43 · click to enlarge
Page 43

PWR : Power LED, ON when external power is applied to the unit.

ACT : ON with port activity for 10 Mbps and 100Mbps operation.

The upper part of the copper port module has a manual Up-link switch, located

An address-aging algorithm causes least-used addresses to fall out in favor of

LK : Steady ON, Link status for 10 Mbps and 100Mbps operation.

position as default factory setting, where used for all-copper module or combo modules.

The Managed 6K25-Series Fast Ethernet copper ports, can be set for either fixed 100Mb

selection is made via MNS software. The factory default setting is for auto-negotiation.

At 10Mb or 100Mb-fixed speed, the user may select half- or full-duplex mode by MNS

All Magnum 6K25 units have address table capacities of 4K node addresses

removed or moved from one segment to another, the 6K25 Switch automatically keeps

100/10 : Speed LED, ON when the speed is 100Mbps , OFF when the speed is 10 Mbps

switching hub in the network. The manual Up-link switch position is configured as (=)

on the inside of the unit on the port module board next to the RJ45 port # 1 which it

The RJ-45 ports independently support auto-cross (MDI or MDIX) in

converter) or fixed mode at 10Mb or 100Mb Half/Full Duplex(managed switch). No

Software for each RJ-45 port separately. For detail information See Section (10.1 at

frequently-used addresses. To reset the address buffer, cycle power down-and-up.

auto-negotiation mode and will work properly with all the other connected devices

with RJ-45 port whether it supports Auto-negotiation or not (e.g 10Mb Hub, media

speed or for 10/100 F/H N-way auto-negotiation per the IEEE802.3u standard. The

page no.52) of this manual to access the “6K-MNS(Rel 3) Software user guide”

suitable for use in larger networks. They are self-learning, so as nodes are added,

F/HFull / Half duplex LED, ON when the port is running full

4.3 Up-link MDI-MDIX on RJ-45 port modules, for port 1 only

controls. It enables the port’s cable to be cascaded (X) to a 10/100Mb repeater or

4.4 Auto-Cross(MDIX) and Auto-negotiation, for RJ-45 ports

cross-over cable is required while using the 6K8’s copper port to other devices.

duplex, OFF for half duplex.

Operation is according to the IEEE 802.3u standard.

For all Magnum 6K25 models :

up with node locations.

4.2 Status LEDs

Address Learning

Page 44 of the GarrettCom 6K25 user manual — 3.6 Connecting the Console Terminal to Magnum 6K25 (Management)
Page 44 · click to enlarge
Page 44

copper ports is to connect one of them using a fiber media converter to another Switch in

desirable to operate the fiber link at 100Mb speed, and at either half- or full duplex mode

Attachment to 10/100 auto-negotiation ports typically will not work properly. The 6K25

possible depending on what the other device supports. These are: (1) 100Mb full-duplex,

Switch’s RJ-45 ports handle this situation by configuring the ports as per desire through

connected to another auto-negotiating device, there are 4 different speed and F/H modes

The auto-negotiation logic will attempt to operate in descending order and will normally

mode” result can change at any time depending on network changes that may occur). If

the device at the other end is not an auto-negotiating device, the 6K25’s RJ-45 ports will

try to detect its idle signal to determine 10 or 100 speed, and will default to half-duplex

MNS software port settings and can check the port status of each port after the change.

When Magnum 6K25 RJ-45 copper ports are set for auto-negotiation and are

arrive at the highest order mode that both devices can support at that time. (Since auto-

-- the devices at both ends of the cable are capable of operation at either 10

depending on the capabilities of the remote device. Standard commercially available

Fast Ethernet media converters mostly do not support auto-negotiation properly, and

require that the switched port to which they are connected be at 100Mb fixed speed.

negotiation is potentially an externally controlled process, the original “highest order

Auto-negotiation per-port for 802.3u-compliant switches occurs when:

One frequently-used application for the Managed Magnum 6K25 Switch

-- the second of the two connected devices is powered up*, i.e., when

the network backbone, or to some other remote 100Mb device. In this case, it is

-- the LINK is re-established on a port after being lost temporarily.

(2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex.

Mb or 100Mb speed and/or in full- or half-duplex mode, and can

send/receive auto-negotiation pulses, and . . .

LINK is established for a port, or

at that speed per the IEEE standard.

General information -

Page 45 of the GarrettCom 6K25 user manual — 4.5 Flow-control, IEEE 802.3x standard
Page 45 · click to enlarge
Page 45

may be limited within that collision domain. The Path Delay Value (PDV) bit-times must

attempting to transmit to one 100Mb port, and in other protracted heavy traffic situations.

Magnum 6K25 Switches implement the 802.3x flow control (non-blocking) on

switch prevents frames from entering the device by forcing a collision indication

burst of activity causes the switch to save frames until its buffer memory is full. This is

Full-Duplex ports, which provides for a “PAUSE” packet to be transmitted to the sender

buffer queue increases, the Switch will send a “RESUME" packet to tell the transmitter

802.3x flow control standard in order to communicate properly during normal operation. Note: When in Half-Duplex mode, the 6K25 Switch implements a

  • NOTE – Some NIC cards only auto-negotiate when the computer system

When operating in 100Mb half-duplex mode, cable distances and hop-counts

account for all devices and cable lengths within that domain. For Magnum 6K25 Fast

sufficient time to let the Switch reduce the buffer space used. When the available free-

allows the available buffer space to improve as the switch catches up with the

that they are in is powered up. These are exceptions to the “negotiate at

Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.

Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long

most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the

transmitting device is commanded to stop transmitting into the 6K25 Switch port for

to start sending the packets. Of course, the transmitting device must also support the

on the half-duplex ports that are receiving. This temporary “collision” delay

Magnum 6K25 Switches incorporate a flow-control mechanism for Full-

10Mb port is unable to keep up. It can also occur when multiple 100Mb ports are

back-pressure algorithm on 10/100 Mb ports for flow control. That is, the

LINK – enabled” rule above, but may be occasionally encountered.

when the packet buffer is nearly filled and there is danger of lost packets. The

4.5 Flow-control, IEEE 802.3x standard

traffic flow.

Page 46 of the GarrettCom 6K25 user manual — (LXSC40)
Page 46 · click to enlarge
Page 46
GarrettCom 6K25 — 3.6 Connecting the Console Terminal to Magnum 6K25 (Management) diagram (page 46)
Fig. 24 · 3.6 Connecting the Console Terminal to Magnum 6K25 (…

and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LXSC25)

and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (LXSC70)

Lucent’) web sites and catalogs to provide guidance to network designers and installers.

mode 18+ (0.4) 1300 9/125 -15 -31 14 28 17.5 35

mode 40 (0.4) 1300 9/125 -5 -34 29 58 32.5 65

15.8 12.2 5.5 4.0

mode 2 (0.4) 1300 62.5/125 -19 -31 12 4 16 5.7

Mode 15+ (0.4) 1310 9/125 -15 -28 11 22 - -

1000Mb Multi- mode 0.55 1300 62.5/125 50/125 -9.5 -17 5.5 2 12.5 4

1000Mb Single- mode 10 1300 9/125 -9.5 -20 8.5 17 10.5 21

Receiver Sensitivity and Transmitter Power are the parameters necessary to

The following data has been collected from component manufacturer’s (Agilent’s and

4.6 Power Budget Calculations for Magnum 6K25 PM’s with Fiber Media

compute the power budget. To calculate the power budget of different fiber media

where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

installations using Magnum products, the following equations should be used:

and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

-31 9.0 5.5 3.0 2.0

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

-23.5 -31

OPB (Optical Power Budget) = PT(min) - PR(min)

mode 2 (0.4) 1300 62.5/125

6KPM-SLC 100Mb FX Single-

(LXSC40)

6KPMMTRJ

6KPMMLC

SXSC

LXSC10

GBIC-

GBIC-

50/125 -20 · 100Mb FX Multi- · 100Mb FX Multi-

Page 47 of the GarrettCom 6K25 user manual — Modules
Page 47 · click to enlarge
Page 47
GarrettCom 6K25 — 3.6 Connecting the Console Terminal to Magnum 6K25 (Management) diagram (page 47)
Fig. 25 · 3.6 Connecting the Console Terminal to Magnum 6K25 (…

This section applies only to PMs shipped as separate items, i.e., 6K25 PMs not

during shipment or delivery. Inspect the contents of this package for any signs

1000Mb Single- mode 25 1550 9/125 -4.0 -21 15 37.5 17.5 43

1000Mb Single- mode 40 1550 9/125 -4.0 -21 15 60 17.5 70

1000Mb Single- mode 70 1550 9/125 -3.0 -23 18 90 20.5 102

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only

  • The worst-case OPB of the fiber link must be greater than the fiber cable’s

keep the shipping container should you need to ship any of the PMs separately

  • The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the

full-duplex (factory default) setting for 100Mbps fiber ports must be used,

installing a 6K25 PM; notify the carrier of any damage you believe occurred

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

Remove the 6K25 PM(s) from the shipping container. Be sure to

at a later date. In the event there are items missing or damaged, contact your

5.0 Introduction - Magnum 6K25 Managed Fiber Switch Port

This chapter describes each Port Module (PM), including appearance,

Examine the shipping container for obvious damage prior to

of damage and ensure that the items listed below are included.

Installation instructions, with illustrations

factory installed in a Magnum 6K25 PM slot.

5.1 Inspecting the Package and Product

1 or more 6K25 PMs

if the following factors are both applied:

functionality, and status displays.

This package should contain:

passive Attenuation.

Modules

and

Page 48 of the GarrettCom 6K25 user manual — ACTIVITY
Page 48 · click to enlarge
Page 48

Modules for flexible mixed-media connectivity to RJ-45 and fiber media. Since

or 8-port interfaces are designed to support all standard Ethernet media types at

10 or 100Mps speed. Each 6K25 PM provides six or eight ports for connecting

RJ-45 ports or used for COMBO module is set as (=) other user ports.

the Magnum 6K25 Switches have dual-speed capability for copper ports, the 6

5.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist lock” Combo Module

10/100Mbps and fiber optic ports at 100MB. The Combo module is equipped with dual-

port supports fiber optic cable distances up the IEEE-standard 100Mbps distance limits,

Link (LK) LED that indicates proper connectivity with the remote device when lit, and

Each 6K25 PM is individually described in the following sections.

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The

supplier. If you need to return the unit, use the original shipping container if

Each port has an Activity (ACT) LED indicating packets being received, a

An important feature of the Magnum 6K25 is the use of Port

For a list of 6K25 Port Module types, refer to Section 1.2

4 Port@ 10/100Mbps and 2 @100 Mb ST Fiber Port

The Magnum 6KP6-RJMST is a combo 6 port module of RJ-45’s at

Ethernet segments with its individual connector type and media.

10/100 LK

F/H ACT

4 FULL/HALF

2 6 TX RX TX LK RX LK

possible. Refer to Chapter 5 for specific return procedures.

1 3 5 7

6KP6-RJMST,

ACT

F/H

LINK 2

i.e., typically 2km at full-duplex and 412m at half-duplex.

ACTIVITY

ACT

F/H

5.2 6KPM Module Description

100m on each port and the fiber

mode ST-type connectors and

segments. When installed in a

supports the standard distance

dual speed copper ports. The

ST-connector functions as a

fiber optic transceiver to

Switch, the copper port

10/100 · support 100BASE-FX network · Magnum 6K25 Managed

Page 49 of the GarrettCom 6K25 user manual — FULL/HALF
Page 49 · click to enlarge
Page 49

distances up the IEEE-standard 10Mbps distance limits, i.e., typically 2km at full-duplex

hub to connect to the switch through 10Mb fiber ports. It supports distances according to

The 6KP6-RJ10ST is a six port combo module that looks similar to

The ST-connector functions as a fiber optic transceiver to support 10BASE-FX network

segments. When installed in a Magnum 6K25 Managed Switch, the copper port supports

Link (LK) LED that indicates proper connectivity with the remote device when lit, and

the 10Base-FL standard i.e, 2Km distance for multi-mode fiber. (Single-mode for 10Km

received, a Link (LK) LED indicating proper connectivity with the remote device when

5.2.1a 6KP6-RJ10ST, 4@10/100Mbps RJ-45 and 2@10Mb multi-mode FX-ST “twist lock” Combo Module

the 100Mb combo module with the exception of 10Mb speed at the ST fiber module.

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The

5.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module

the standard distance 100m on each port and the fiber port supports fiber optic cable

Each port has an Activity (ACT) LED indicating packets being received, a

lit, and FDX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).

10/100 LED indicates the speed, if the LED is ON, 100Mbps if it is OFF, 10Mbps.

Each port has an Activity (ACT) LED indicating packets being

10/100 LED indicates the speed, if the LED is ON 100Mbps if it is OFF 10Mbps.

1 ACTIVITY LINK 2

RX

TX RX LK

4 Port@ 10Mb ST Fiber Port

LK

6KP4-RJ10MST,

2 6 T

ACT

F/H

ACT

F/H

switch. They also provide a convenient way for the half duplex

FULL/HALF

TX RX LK

TX RX LK

ACT

ACT

F/H

F/H

distance may be available as a special order).

their legacy 10Mb network

Fiber ports. All four fiber

and configured as 10Mb

The 10Mb ST-fiber ports

allow the user to connect

is a 10Mb multi-mode

fiber module with 4 ST-

ports are ST connectors

Half-duplex by default.

to the Magnum 6K25

and half-duplex.

The Magnum 6KP4-F10ST

Page 50 of the GarrettCom 6K25 user manual — 2@10Mb & 2@100Mb multi-mode
Page 50 · click to enlarge
Page 50
GarrettCom 6K25 — 3.6 Connecting the Console Terminal to Magnum 6K25 (Management) diagram (page 50)
Fig. 26 · 3.6 Connecting the Console Terminal to Magnum 6K25 (…

All four fiber ports are ST connectors and configured as 10Mb Half-duplex by default for

provide a convenient way for the half duplex hub to connect to the switch through 10Mb

10Mb fiber and 100Mb Full duplex for the 100Mb fiber. The 10Mb ST-fiber ports allow

received, a Link (LK) LED indicating proper connectivity with the remote device when

the user to connect their legacy 10Mb network to the Magnum 6K25 switch. They also

distance for multi-mode fiber. (Single-mode for 10Km distance may be available as a

fiber ports. Whereas the 100Mb ST module allow to connect the 100Mb demand of

lit, and FDX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).

4 Port@ 10/100Mbps and 2 @100 Mb SC Fiber Port

Switch devices. It supports distances according to the 10Base-FL standard i.e, 2Km

Each port has an Activity (ACT) LED indicating packets being

5.2.2. 6KP6-RJMSC 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-SC “snap-in” Fiber connector

F/H ACT

4 FULL/HALF

10/100 LK

4 Port@ 10Mb ST Fiber Port

2 6 TX RX TX LK RX LK

1 3 5 7

6KP4-RJ10MST,

6KP6-RJMSC,

F/H ACT

F/H

LINK 2

ACTIVITY

ACT

transceivers all in one module. This

is similar to the 6K6-RJMST. It has

module equipped with 4 10/100Mb

RJMSC is also a Combo 6 Port

RJ-45 ports along with 2 multi-

the same LEDs indicating port

activity (ACT), Link (LK), and

FX-ST “twist

lock” Module

FLSTFX is a combo fiber

module with two 10Mb +

combine 4 ST-Fiber ports.

mode 100Mbps fiber optic

2@10Mb & 2@100Mb multi-mode

5.2.1c 6KP4FLSTFX,

fiber module and in

special order).

Show 4 more labels / short text on this page
10/100 · The Magnum 6KP6- · two 100Mb multi-mode · The Magnum 6KP4-
Page 51 of the GarrettCom 6K25 user manual — ACT
Page 51 · click to enlarge
Page 51

While the functionality of these two modules is essentially the same, the 6KP6-

copper at the 100m distance. The Fiber is single-mode and cable lengths can be as much

Link (LK) LED that indicates proper connectivity with the remote device when lit, and a

ports and 2 Single-mode (Long Reach) SC-type connectors. It provides a combination of

5.2.3 6KP6-RJSSC 4@ 10/100Mbps RJ-45 Ports and 2@100Mbps single-mode FX-SC-type, “snap-in” connector

5.2.4 6KP6-RJSSCL 4 @ 10/100 Mb copper port and 2@100Mbps single-mode FX-SC-type, “snap-in” connector

The Magnum 6KP6-RJSSC is also a Combo module equipped with 4 dual speed copper

copper and Fiber functions in one module to the 6K25 Switches, supporting four Copper

supporting the 100m distance and Fiber supporting single-mode fiber cable lengths of as

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The

distinguish the single-mode 6 K6-RJSSC from the multi-mode 6K6-RJMSC, the label

Each port has an Activity (ACT) LED indicating packets being received, a

The 6KP6-RJSSC, when installed in a Magnum 6K25 Switch operates on

The 6KP6-RJSSC, when installed in a Magnum 6K25 Switch has copper

10/100 LED indicates 100Mbps speed when lit and 10Mbps speed when off. To

RJMSC is equipped with an SC-type "snap-in" connector instead of an ST-type.

4 Port@ 10/100Mbps and 2 @100 Mb SSC Fiber Port

4 FULL/HALF

10/100 LK

F/H ACT

FDX / HDX and 10/100 operation, and the same face-plate lettering.

2 6 TX RX TX LK RX LK

supporting four Copper and two single-mode fiber network segments.

1 3 5 7

6KP6-RJMSSC,

ACT

and two single-mode (Long-Reach) fiber network segments.

F/H

“Sgl. M.” is at the top of the faceplate of the 6K6-RJSSC.

LINK 2

ACTIVITY

much as 40+ Km (see Power Budget, Section 4.5)

ACT

F/H

as 25+ Km (see Power Budget, Section 4.5)

equipped with 4 dual speed

mode SC-type connectors. It

module of the 6K25 Switch

copper ports and 2 Single-

and Fiber functions in one

is also a Combo module

Show 4 more labels / short text on this page
10/100 · The Magnum 6KP6-RJSSC · through combining copper · provides an advantage
Page 52 of the GarrettCom 6K25 user manual — 2 4 6 8 LK LK LK LK
Page 52 · click to enlarge
Page 52

The Magnum 6KP6-RJ10ST is also a Combo module equipped with 4 dual speed copper

5.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factor

Magnum 6KP8-MTRJ is a multi-mode fiber optic 8-port module equipped with

10/100 LED indicates the speed for the copper port, which is 100Mbps when the LED is

copper and Fiber functions in one module to the 6K25 Switches, supporting four Copper

Link (LK) LED indicating proper connectivity with the remote device when lit, and a

5.2.4a 6KP6-RJ10ST 4 @ 10/100 Mb copper port and 2@10Mbps multi-mode FL-ST-type, “twist-lock” connector

ports and 2 multi-mode 10 Mb fiber ST-type connectors. It provides a combination of

proper connectivity with the remote device when lit, and a FDX/HDX LED indicating

speed for the copper port, which is 10Mbps when the LED is ON and 10 Mb when the

8 Port@ 100Mbps Multi-Mode Fiber port

Each port has an Activity (ACT) LED indicating packets being received, a

FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). The

The 6KP6-RJ10ST, when installed in a Magnum 6K25 Switch has copper

Activity (ACT) LED indicating packets being received, a Link (LK) LED indicating

supporting the 100m distance and Fiber supporting multi-mode fiber cable allow to

connect the legacy network of 10Mb requirement in the network. Each port has an

full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the

FULL/HALF 1 ACTIVITY

“small-form-factor”

ACT

F/H

ACT

F/H

ACT

F/H

ACT

F/H

F/H LK LK LK LK

1 3 5 7

2 4 6 8 LK

6KP8-MTRJ,

LINK

ACT

F/H

ACT

ACT

ACT

F/H

F/H

and two 10Mb of ST fiber network segments.

ON and 10 Mb when the LED is OFF.

an RJ-45 port, but it is black in

and ease of connection make it

connectivity. When installed in

distances up the IEEE-standard

connector. It looks almost like

color. The MT-RJ’s small size

100Mbps distance limits, i.e.,

a good choice for 100Mbps

a Magnum 6K25 Switch, it

supports fiber optic cable

LED is OFF.

a small-form-factor MTRJ-type · “fiber-to-the-desktop” Ethernet

Page 53 of the GarrettCom 6K25 user manual — MTRJ Small-Form-Factor
Page 53 · click to enlarge
Page 53

10/100 LK 1

The functionality of this 100BASE-FX multi-mode 8 Port module is essentially

with two different speeds. The top four ports of MTRJ Small form factor fiber support at

the same as the ST and SC-types. It has the same LEDs per port indicating port activity

The 6KP6-RJ10ST is a combo module with two different kinds of fiber flavor

Fiber connector supports the standard fiber optic distance limit of 2Km at Full and Half-

3 2 4 6 8 LK

5.2.5a 6KP6-MT10ST, 4 @100Mb multi-mode FX , MTRJ Small-Form- Factor and 2@ 10Mb Multi-mode ST-Fiber port

100Mb full-duplex, whereas the bottom two ports multi-mode ST-Fiber support 10Mb

half-duplex. This combo module provides more flexibility to the user to connect their

supports fiber optic cable distances up to the IEEE-standard 100Mbps distance limits,

i.e., typically 2km at full-duplex and 412m at half-duplex. The 10Mb Multi-mode ST-

The functionality of this 100BASE-FX multi-mode 4 port module is

5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX ,

4 Port@ 10/100Mbps & 4 port @ 100Mbps

4 FULL/HALF

When installed in a Magnum 6K25 Switch, the 100Mb MTRJ connector

essentially the same as the ST and SC-types. It has the same LEDs per port

F/H ACT

indicating port activity (ACT), Link (LK), and FDX or HDX operation

ACT

F/H

ACT

F/H

1 3 5 7

6KP8-45MT

LINK 2

legacy 10Mb fiber as well as 100Mb to the Magnum 6K25 Switch.

ACTIVITY

typically 2km at full-duplex and 412m at half-duplex.

ACT

F/H

ACT

F/H

(ACT), Link (LK), and FDX or HDX operation.

MTRJ Small-Form-Factor

copper and fiber (Small Form Factor)

of placing more ports on one module.

10/100 RJ-45 ports and 4 MTRJ fiber

MTRJ connectors give an advantage

The 6KP8-45MT is equipped with 4

MTRJ type ports. The small size of

Module is a combo module with

duplex both.

ports.

10/100 · Multi-Mode Fiber port · The Magnum 6KP8-45MT

Page 54 of the GarrettCom 6K25 user manual — ACTIVITY
Page 54 · click to enlarge
Page 54

at half-duplex.The compact size of the LC Connector reduces the size of wiring panels in

more ports on one module. The

6KP8-45LC is equipped with 4

mentioned on 5.2.3. and the LEDs also

the IEEE-standard 100Mbps distance limits, i.e., typically 2km at full-duplex and 412m

technology.The cable end is a “plug-in” connector with both fiber strands terminated in

indicating packets being received, a Link (LK) LED indicating proper connectivity with

the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit

copper and Fiber (Small Form

10/100 RJ-45 ports and 4 LC(

Small form factor) multi-mode

5.2.7 6KP8-MLC, 8 ports @ 100Mbps multi-mode LC connector Small-

When installed in a Magnum 6K25 Switch, it supports fiber optic cable distances up to

one housing that cannot be improperly inserted. Each port has an Activity (ACT) LED

The Magnum 6KP8-45LC Module is a combo module with a combination of

small size of LC connectors

give an advantage of having

When installed in a Magnum

6K25 Switch, it supports the

Magnum 6KP8-MLC is a

5.2.8 6KP8-45LC, Combo 4@ 100Mbps multi-mode -LC small-form factor and 4@ 10/100 Mbps RJ-45 Connector

Factor) LC type ports. The

primarily in 100Mbps fiber-to-the-

When installed in a Magnum 6K25 Switch, it supports the standard distances as

eight-port multi-mode fiber LC

Form Factor

wiring closets while providing the advantage of “future-proof” fiber optic

fiber ports.

desktop links.

act similarly.

10/10 LK 1

3 2 4 6 LK LK LK

GarrettCom 6K25 — 10/10 LK 1 diagram (page 54)
Fig. 27

4 FULL/HALF

8Port@ 100Mbps multi-mode LC fiber port

4 Port@ 10/100Mbps & 4 port @ 100Mbps

F/ ACT

ACT

F/H

ACT

F/H

LINK 2

(or half-duplex when off).

Multi-Mod LC Fiber port

ACTIVITY

F/H

F/H

AC

AC

connector “small-form-factor” used · 10/10

Page 55 of the GarrettCom 6K25 user manual — 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port
Page 55 · click to enlarge
Page 55

3 F/H ACT

Auto-crossover (MDIX), which allow the RJ-45 ports to automatically Link with any RJ-

could produce kigh (greater than 2500V ) levels of ground potential rise (GPR)

during line-to-ground fault conditions. The 6K25 passes the 1613specifications

and will allow both unshielded twisted pair (UTP) and shielded twisted pair (STP) cable

feature eliminates the need for a special twisted pair crossover cable when connecting to

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off), and a

for zero packet loss with fiber ports & with RJ45 ports used as indicated here.

10/100 LK 1

telecommunication multiplexers installed in close proximity (i.e., less than 2

Each port has an Activity (ACT) LED indicating packets being received, a

Link (LK) LED that indicates proper connectivity with the remote device when lit, a

substation applications to interface to field devices across distances which

Crossover (MDI-X) switch, which controls all ports for cascaded connection. This

advises that, for substation applications, the RJ-45 ports are intended for

standard distances as per mentioned on 5.2.8. and the LEDs also acts similarly as

connections. The 6KP8-RJ45 module is equipped with a Media Dependent Auto-

meters or 6.5ft) to the 6K25. It is not recommended to use these ports in

4 FULL/HALF

2 4 6 8 F/ H ACT

10/100 LK

connectivity to other communication equipment such as routers or

8 Port@ 10/100Mb Copper ports

1 3 5 7

“10/100” LED indicating 100Mb when lit (or 10 Mbps when off).

5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port

6KP8-RJ45,

LINK 2

ACTIVITY

45 device and eliminate the use of cross-over cable.

shielded to minimize emissions

standard length. It is equipped

negotiating capability on each

twisted pair segments of any

connector, and offers 10/100

port. The RJ-45 connector is

with an eight-port RJ-45

a hub or another switch.

full / half-duplex auto-

mentioned above.

10/100 · The 6KP8-RJ45 · module supports Ethernet

Page 56 of the GarrettCom 6K25 user manual — PoE
Page 56 · click to enlarge
Page 56

devices. The PoE LED is ON when the attached PD is drawing power from the

standard. Only 4 x RJ-

option in one 6K-unit.

available with mix –n-

PoE LED is ON when connected properly to a 803.af compliant PD device on that port.

When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

through, so the 48VDC power source must be strong enough to provide power

to the 6K switch and to all the 8 RJ-45 ports with PD devices connected (up to

15 watts per PoE port). • In the case where the 48VDC power in not internally connected and no power

5.2.11 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8-

5.2.10 New PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-port

In this Fig. the top 4-

normal MDIX ports.

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

  • For non-PoE devices connected, the PoE port will act as a normal RJ-45 port

match with fiber modules. Please check the ordering information Sec.1.2. for all the

is coming to the PoE ports for some reason, all the PoE port LEDs are ON

The PoE RJ-45 ports act similar to regular RJ-45 ports, except they have

IEEE802.3af PoE

45 (10/100) ports maxm. support

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to

simultaneously to indicate a trouble condition. The ports will still operate

  • For PoE devices, each RJ-45 PoE port supports only 802.3af complaint
  • The PoE ports in Magnum 6K’s with 48VDC power input act as a pass-

capability of providing power on each port to power up the PD devices, per the

and the PoE LED is OFF. No power is being sent out from the port.

10/10 LK/AC 1

3 F/H POE

2 1 3 5

that is marked as LINK/ACT, as shown in the diagram.

10/10 LK/AC

4 FULL/HALF

various PI6K PoE modules option.

properly for data traffic.

2 4 6 F/ H POE

8 Port@ 10/100Mb Copper ports

traffic is not affected by PoE.

6KP8-45RJ

LINK LK / ACT 2

port.

PoE

Show 10 more labels / short text on this page
bottom 4- RJ-45 are · POE(Power Inside) · enhanced with POE · option whereas as · The 4-RJ45 POE · module are also · RJ45 ports are · 10/10 · PoE LEDs Summary · port
Page 57 of the GarrettCom 6K25 user manual — 6KP8-45RJ
Page 57 · click to enlarge
Page 57

15watts to power up the PoE PD devices. In this

ports are enhanced with

POE option The 8-RJ45

devices. The PoE LED is ON when the attached PD is drawing power from the

input power supply to

POE module are also available with mix –n-match with fiber modules. Please check the

PoE LED is ON when connected properly to a 803.af compliant PD device on that port.

When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

through, so the 48VDC power source must be strong enough to provide power

to the 6K switch and to all the 8 RJ-45 ports with PD devices connected (up to

15 watts per PoE port). • In the case where the 48VDC power in not internally connected and no power

5.2.12 6KP8-45-2MT, 6@ 10/100Mbps RJ-45 and 2@100Mb multi-mode FX , MTRJ Small-Form-Factor

standard. The Power

(10/100) ports. Each

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

  • For non-PoE devices connected, the PoE port will act as a normal RJ-45 port

Fig. the top 8-RJ45

is coming to the PoE ports for some reason, all the PoE port LEDs are ON

The PoE RJ-45 ports act similar to regular RJ-45 ports, except they have

IEEE802.3af PoE

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to

simultaneously to indicate a trouble condition. The ports will still operate

  • For PoE devices, each RJ-45 PoE port supports only 802.3af complaint
  • The PoE ports in Magnum 6K’s with 48VDC power input act as a pass-

capability of providing power on each port to power up the PD devices, per the

and the PoE LED is OFF. No power is being sent out from the port.

ordering information Sec.1.2 for all the various P6K PoE modules option.

GarrettCom 6K25 — 5.2.12 6KP8-45-2MT, 6@ 10/100Mbps RJ-45 and 2@100Mb multi-mode FX , MTRJ Small-Form-Factor diagram (page 57)
Fig. 28 · 5.2.12 6KP8-45-2MT, 6@ 10/100Mbps RJ-45 and 2@100Mb…

that is marked as LINK/ACT, as shown in the diagram.

properly for data traffic.

8 Port@ 10/100Mb Copper ports

traffic is not affected by PoE.

6KP8-45RJ

port.

Show 7 more labels / short text on this page
support more RJ-45 · modules are totally · dependent upon the · powerful -48VDC · port require atleast · Pass-through PoE · PoE LEDs Summary
Page 58 of the GarrettCom 6K25 user manual — 6KP8V6KP8-45-2MT
Page 58 · click to enlarge
Page 58

5.2.12a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor

GarrettCom 6K25 — 5.2.12a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor diagram (page 58)
Fig. 29 · 5.2.12a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb…

The Magnum GBIC-SXSC is a multi-mode Gigabit fiber connector

supports cable distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e.,

6KP8V6 Port@ 10/100Mbps & 2 port @ 100Mbps

5.2.13 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector

GarrettCom 6K25 — 5.2.13 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector diagram (page 58)
Fig. 30 · 5.2.13 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode S…

100Mb MTRJ fiber ports. When installed in a Magnum 6K25 Switch, it supports the

equipped with SC type connectors and can be easily snapped in and out. The Gigabit

fiber ports are most popular as server-to-switch and switch-to-switch applications. It

When installed in a Magnum 6K25 Switch, it supports the standard distances as

6 Port@10/10Mbps & 2 port @100Mb Multi-Mode Fiber port

standard distances as mentioned on 5.2.3. and the LEDs also act similarly.

Single-Mode Fiber port (LC)

6KP8V6KP8-45-2MT

mentioned on 5.2.4. and the LEDs also act similarly.

fiber (Small Form Factor) LC type

give an advantage of placing more

The small size of LC connectors

10/100 RJ-45 ports and 2 Single-

45-2MT eight port Module is a

combo module with copper and

sizes of MTRJ connectors give

fiber ports on one module. The

6KP8-45-2MT is equipped with

six 10/100 RJ-45 ports and two

combo module with copper and

ports on one module. The 6KP8-

an advantage of placing more

45SLC eight port Module is a

MTRJ type ports. The small

45-2SLC is equipped with 6

fiber (Small Form Factor)

mode fiber ports.

fiber ports.

The Magnum 6KP8- · The Magnum 6KP8-

Page 59 of the GarrettCom 6K25 user manual — 5.2.14 6KM-BLNK
Page 59 · click to enlarge
Page 59

550m at full duplex.

removing the transceiver, press the clips on either side of the transceiver at the same time

suggestions listed below prior to contacting your supplier. However, if you are unsure of

Each port has an Activity (ACT) LED indicating packets being received and a

supports cable distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e.,

Each port has an Activity (ACT) LED indicating packets being received and a link (LK)

intended to help locate, identify and correct these types of problems. Please follow the

10,25, 40 or 70Km at full duplex, and depend upon the Gigabit modules used.

The 6KM-BLNK is a blank face plate or cover plate that must be installed in

Magnum 6K25 Switch is a straightforward procedure (see INSTALLATION, Section

The GBIC transceiver is fastened using snap-in clips. Insert the transceiver

5.2.13a GBIC-LXSC & ZXSC Gigabit fiber (1000Mb), single-mode SC Connector

The Magnum GBIC-LXSC/ZXSC is a single-mode Gigabit fiber connector

equipped with SC type connectors and can be easily snapped in and out. The Gigabit

fiber ports are most popular as server-to-switch and switch-to-switch applications. It

(take care to insert it the right way up, arrows on top) until it clicks in space. While

consistently high performance in all network environments. The installation of a

Should problems develop during installation or operation, this section is

Link (LK) LED indicating proper connectivity with the remote device when lit.

All Magnum Ethernet products are designed to provide reliability and

2.6); the operation is also straightforward and is discussed in Section 4.

LED indicating proper connectivity with the remote device when lit.

6.0 TROUBLESHOOTING

underneath the front panel hold

the 6KM-BLNK in place.

and pull the transceiver out.

any empty 6K25 PM slot to

maintain proper cooling air

5.2.14 6KM-BLNK

flow, safety, etc.

Two screws

Page 60 of the GarrettCom 6K25 user manual — 6.1 Before Calling for Assistance
Page 60 · click to enlarge
Page 60

the procedures described in this section or if the Magnum 6K25 Switch is not performing

as expected, do not attempt to repair the unit; instead contact your supplier for assistance

known good device. Verify whether or not the problem is corrected. If not, go

to Step 5 below. If the problem is corrected, the Magnum 6K25 Switch and its

1. If difficulty is encountered when installing or operating the unit, refer back to
3. Make sure that an AC power cord is properly attached to each Magnum 6K25

Switch unit. Be certain that each AC power cord is plugged into a functioning

Switch product, it is recommended that the problem device be replaced with a

5. If the problem continues after completing Step 4 above, contact your supplier

of the Magnum 6K25 Switch unit or if unknown, contact GarrettCom, Inc.by

d. Any particular application that, when used, appears to create the problem;

the Installation Section of the applicable chapter of this manual. Also check

electrical outlet. Use the PWR LEDs to verify each unit is receiving power.

4. If the problem is isolated to a network device other than the Magnum 6K25

to make sure that the various components of the network are interoperable.

number(s). Include the date(s) that you purchased the products from your

2. Check the cables and connectors to ensure that they have been properly

impaired during installation. (About 90% of network downtime can be

1. A complete description of the problem, including the following points:

connected and the cables/wires have not been crimped or in some way

2. An accurate list of GarrettCom product model(s) involved, with serial

fax, phone or email (support@garrettcom.com) for assistance.

Please be prepared to provide the following information.

attributed to wiring and connector problems.)

c. The components involved in the problem;

associated cables are functioning properly.

a. The nature and duration of the problem;

b. Situations when the problem occurs;

6.1 Before Calling for Assistance

6.2 When Calling for Assistance

or contact GarrettCom Customer Support.

supplier.

Page 61 of the GarrettCom 6K25 user manual — 6.4 Shipping and Packaging Information
Page 61 · click to enlarge
Page 61

sheet or bag for shipping protection. ( You may retain all connectors and this

All returns for repair must be accompanied by a Return Material Authorization

1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic

material. This material may cause electro-static shock damage to the unit.

4. A record of changes that have been made to your network configuration prior

CAUTION : Do not pack the unit in Styrofoam "popcorn" type packing

3. It is useful to include other network equipment models and related hardware,

including personal computers, workstations, terminals and printers; plus, the

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

GarrettCom will carefully test and evaluate all returned products, will repair products

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

to the occurrence of the problem. Any changes to system administration

that are under warranty at no charge, and will return the warranty-repaired units to

the sender with shipping charges prepaid (see Warranty Information, Appendix A,

units under warranty. Testing and repair of product that is not under warranty will

Should you need to ship the unit back to GarrettCom, please follow these

GarrettCom reserves the right to charge for the testing of non-defective

for complete details). However, if the problem or condition causing the return

3. GarrettCom is not responsible for your return shipping charges.

Failure symptoms, including a full description of the problem.

6.3 Return Material Authorization (RMA) Procedure

(RMA) number. To obtain an RMA number, please use this URL -

cannot be duplicated by GarrettCom, the unit will be returned as:

Name and phone number of your contact person.

Please have the following information readily available:

Packing List Number (or Sales Order Number)

procedures should all be noted in this record.

6.4 Shipping and Packaging Information

various network media types being used.

No Problem Found.

Name of your company / institution

Serial Number (or Invoice Number)

result in a customer (user) charge.

Installation Guide.)

instructions:

Your shipping address · Date of installation · Product name

Page 62 of the GarrettCom 6K25 user manual — Attn.: Customer Service
Page 62 · click to enlarge
Page 62

GarrettCom, Inc. warrants its products to be free from defects in materials

B1.0 SPECIFICATIONS FOR MAGNUM 6K25 SWITCHES, DC POWER

replace components in the products that prove to be defective at no charge other

product has been damaged by misuse, misapplication, or as a result of service or

This warranty will not be effective if, in the opinion of GarrettCom, the

Please complete the warranty card as this acts as a product registration,

and workmanship for a period of three (3) years from the date of shipment by

than shipping and handling, provided that the product is returned pre-paid to

inspecting any product returned for warranty repair which turns out not to be

During this warranty period, GarrettCom will repair or, at its option,

Power ConsumptionSame as for AC models (see Section 1.1)
Power ConsumptionSame as for AC models (see Section 1.1)

GarrettCom reserves the right to make a charge for handling and

Power Supply (Internal 125 VDC Option) Industrial Applications

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

Power Supply (Internal 24 VDC Option) Industrial Applications

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

and mail it to GarrettCom within two weeks of your purchase.

APPENDIX B : Internal DC Power Supply Options

APPENDIX A: WARRANTY INFORMATION

47823 Westinghouse Dr.

Input Voltage36 - 70 VDC
Input Voltage20 - 36 VDC

Attn.: Customer Service

modification other than by GarrettCom.

Power Supply (Internal -48VDC Option)

GarrettCom, Inc.

4. Ship the package to:

GarrettCom.

GarrettCom.

faulty.

Fremont, CA 94539-7437

Page 63 of the GarrettCom 6K25 user manual — A+
Page 63 · click to enlarge
Page 63

connection, for example, will neither affect the Switch, its internal power supply, nor will

The manual power “On-Off” Switch (optional) is used for powering the unit on

The –48VDC solution is particularly useful in the telecommunication industry,

other communication companies. In addition, many high availability equipment services,

facilities often use a battery backup system to maintain operations in the event of a power

environment, where it is common facilities to operate on 24VDC or 125VDC power. The

The -48VDC, 24VDC and 125VDC power options are designed using diodes

inside on each DC power input line behind the two external power connection terminals,

Magnum 6K25 Fiber Switches are easily installed in a variety of applications

where -48VDC, 24VDC and 125VDC power is used as the primary power source. The-

where it is common for facilities to operate on -48VDC power. Such companies include

regular and wireless telephone service providers, Internet Service Providers (ISPs) and

B2.0 -48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION

48VDC, 24VDC and 125VDC power configuration provides an Ethernet networking solution utilizing a special power supply in a managed Fiber Switch.

The 24VDC and 125VDC solution are particularly useful in the Industrial

125VDC solution is mainly used in power utilities, such as electrical substations, electrical generating plants, etc. The 24VDC applications are mainly in the Industrial

functions of Magnum 6K25 Switch -48VDC, 24VDC and 125VDC models are

GND GND CHASSIS

It protects the Switch from incorrect DC input connections. An incorrect polarity

such as broadcasters, publishers, newspaper operations, brokerage firms and other

With the exception of the power supply, all specifications and

FUSE +

failure. It is also frequently used for computer system backup, management and

environment, such as factory floor, HVAC equipment, military equipment, etc.

Power ConsumptionSame as for AC models (see Section 1.1)

HUB POWER SWITCH

SUPPLY

B3.0 APPLICATIONS FOR DC POWERED SWITCHES

and off when it is placed into or taken out of service.

Input Voltage88 - 150 VDC

identical to those listed in the main manual.

it blow the fuse in the internal power supply.

A+

A-

correctly applied to the two inputs.

so that the power from an external

source can only flow into the hub.

operations monitoring equipment.

This allows the Switch to operate

only whenever DC power is

Page 64 of the GarrettCom 6K25 user manual — B4.0 INSTALLATION
Page 64 · click to enlarge
Page 64
positive (+), Figure B4.0-48VDC Terminal Block on Magnum 6K25-48VDC

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage

1. Minimum 18AWG cable for connection to a Centralized DC power source. 2. Minimum 14AWG cable for connection to a earthing wiring. 3. Use only with Listed 10 A circuit breaker provided in building installation. 4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.

The actual connection procedure is very straightforward. Simply connect the

An ON-OFF manual switch is optional for DC power. This can be used to cut

5. Fastening torque of the lugs on the terminal block: 9 inch-pound max. 6. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rac,k at least 4 inches apart, with the first one located

This section describes the installation of the -48 VDC, 24VDC and 125VDC

power source leads to the -48 VDC, 24VDC and 125VDC power terminal block on the

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

leads to the Magnum unit, beginning with ground. Ensure that each lead is securely

_ + GND

36-70VDC

user may elect to Ground either + or = terminal to suit the customer’s use.

lead from 48V or –48V supply must be connected to the post labeled “+”.

off power connections and as a RESET for the Magnum 6K25 Switch.

OFF

ON

The leads are identified as negative (-),

B4.1 UL Requirements for DC-powered units

within 6 inches of the terminal block.

terminal block on the Magnum 6K25 is

Magnum 6K25s. (see figure at right).

In this picture, the -48VDC

lead posts. It is similar for 24VDC and

located on the rear of the unit and is

equipped with three (3) screw-down

125VDC options on Magnum 6K25.

B4.0 INSTALLATION

and chassis ground (GND).

tightened.

Page 65 of the GarrettCom 6K25 user manual — B5.0 OPERATION
Page 65 · click to enlarge
Page 65

Operation of Magnum 6K25 Switches with the optional -48VDC, 24VDC and

To order the optional -48VDC power supply factory installed, add a suffix of “-

24VDC and 125VDC models with this Dual-Source option are identical to those listed in the Magnum 6K25 Fiber Switches Installation and User Guide, including Appendix B

GNDTerminal for “earth” or ground wire connection to the hub chassis
GNDTerminal for “earth” or ground wire connection to the hub chassis
GNDTerminal for “earth” or ground wire connection to the hub chassis

C2.0 MAGNUM 6K25, with -48VDC, 24VDC and 125VDC Dual-Source option

Similarly to order the optional 24VDC or 125VDC industrial specific power

DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”

-48VDC” after the product’s standard model # Example: Magnum 6K25R-48VDC.

supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s

With the exception of the dual DC input power connections and the power

supply, all specifications and configuration options for the Magnum 6K25 -48VDC,

The 6K25-Switch models with the internal -48VDC, 24VDC and 125VDC

Dual-Source power supply are designed for installations where a battery plant is the

power source, and where two separate power sources are utilized in order to increase

standard model #. Example: Magnum 6K25- 24VDC, Magnum 6K25-125VDC.

Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-24V)

125VDC power supply is identical to that of the standard AC-powered models.

Power Supply (Internal, -48VDC Dual-Source, model # Dual-Src-48V)

Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)

C1.0 SPECIFICATIONS - FOR MAGNUM 6K25 FIBER SWITCH

InputTwo separate sources, each at 88 - 150 VDC

APPENDIX C: Internal DC Dual-Source Power Option

InputTwo separate sources, each at 36 - 70 VDC
InputTwo separate sources, each at 20 - 36 VDC

Please refer to Section 6.0 for troubleshooting

operational uptime and to simplify maintenance.

B6.0 ORDERING INFORMATION

B7.0 TROUBLESHOOTING

“Internal DC Power Supply Option”

B5.0 OPERATION

Page 66 of the GarrettCom 6K25 user manual — C5.0 INSTALLATION
Page 66 · click to enlarge
Page 66

The functionality of the Magnum 6K25 Switch -48VDC, 24VDC and 125VDC

d) Reverse polarity connections, if they should accidentally occur on either input, will not damage

positive(B+). The chassis “earth” or ground (GND) is a threaded post with a #6 nut. The

Terminal Block on a Magnum 48VDC with Dual-Source option

Dual-Source Option units is identical to the standard AC-powered models. Refer to the

GarrettCom 6K25 — 3.6 Connecting the Console Terminal to Magnum 6K25 (Management) diagram (page 66)
Fig. 31 · 3.6 Connecting the Console Terminal to Magnum 6K25 (…

a) The Switch unit can receive power from either input, “A” or “B”. The hub will normally draw

125VDC dual source leads to the -48VDC, 24VDC 7 125VDC power terminal block on the Magnum 6Ks Switch (shown in Figure )

Figure C5.0-48VDC Dual-Source, wiring connections to the External

b) The Switch unit will not allow power to flow from a higher voltage input to a lower voltage

c) When one correct DC input is present, the Switch will receive power if the other DC input is

the Switch or power supply internally (nor will it blow the fuse in the internal power supply)

e) The Switch will not receive power (and will not work) when both inputs are simultaneously

can only flow into the unit. This allows the unit to operate whenever DC power is

because of the blocking action of the diodes. This is true even if one input connection is

This section describes the proper connection of the -48VDC, 24VDC and

The -48VDC terminal block on the Magnum 6K25 Switch, as shown in Fig C5.0 is

36-70VDC

main sections of this Installation and User Guide for a detailed description of the

C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN

36-70VDC GND

absent, or even if it is connected with reverse polarity or shorted or grounded.

C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION

A+ AB- B+

Dual Source terminal block for the 24VDC and 125VDC are similar.

its power from the DC source with the highest voltage at a given time.

input, i.e. the two DC power sources are not mixed together by the hub.

reversed while the Switch is operating from the other source.

correctly applied to either or both of the two inputs

B+

A-

B-

absent or are both incorrectly connected.

located on the right rear of the unit and

is located on the left rear. The primary

(A+), negative (A-), and the secondary

The Dual-Source DC power

option is designed using diodes inside

of the chassis on each DC power input

external power connection terminals)

so that power from an external source

is equipped with five (5) screw-down

lead posts. If it is the reverse model it

line. A diode is placed in each of the

terminals are identified as positive

power terminals as negative (B-),

four input lines (behind the four

C5.0 INSTALLATION

Magnum 6K25 Switches.

Page 67 of the GarrettCom 6K25 user manual — C6.0 ORDERING INFORMATION
Page 67 · click to enlarge
Page 67

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage

1. Minimum 18 AWG cable for connection to a Centralized DC power source. 2. Minimum 14 AWG cable for connection to earthing wiring. 3. Use only with Listed 10 A circuit breaker provided in building installation. 4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.

Dual-Src-48V for the regular DS model with no ON-OFF switch

The connection procedure is straightforward. Simply connect the DC leads to

The 24VDC & 125VDC terminal block on Magnum 6K25’s is similar to that

5. Fastening torque of the lugs on the terminal block: 9 inch pound max. 6. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground

(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely

Similarly, order the “Dual –source 24VDC” or “Dual-source 125VDC” as a

Or Dual-Src125V-Switch for models with the ON-OFF switch

Operation of the Dual-Source Magnum 6Ks-48VDC, 24VDC and 125VDC

The following must be adhered to in order to conform to UL requirements:

To order the optional Dual-Source -48VDC power supply factory installed,

order “Dual-Src48V” as a separate line item following the product model.

or Dual-Src48V-SWITCH with the ON-OFF manual switch.

ExampleMagnum 6K25R-24VDC or Magnum 6K25R-125VDC

Dual-Src24V for regular models with no ON-OFF switch

user may elect to Ground either + or = terminal to suit the customer’s use.

lead from 48V or –48V supply must be connected to the post labeled “+”.

Switch models are identical to that of the standard models.

separate line item following the product model.

ExampleMagnum 6K25R-48VDC

within 6 inches of the terminal block.

described in the –48VDC information above.

C6.0 ORDERING INFORMATION

C7.0 OPERATION

C5.1 UL Requirements

tightened.

Ask about the GarrettCom 6K25

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom 6K25

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom 6K25 manual PDF

67 pages·850 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%