Installation and User Guide
Magnum 6K25
Hardware

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is
Magnum 6K25 Switch products, consult Section 6, Troubleshooting, of
serviceable parts. Attempted service by unauthorized personnel shall
render all warranties null and void. If problems are experienced with
of this publication may be reproduced without prior written permission from
Copyright © 2006 GarrettCom, Inc. All rights reserved. No part
Managed Fiber Switch
UL is a registered trademark of Underwriters Laboratories
NEBS is a trademark of Telcordia Technologies
Ethernet is a trademark of Xerox Corporation
a registered trademark of GarrettCom, Inc.
Printed in the United States of America.
this User Guide.
GarrettCom, Inc.
Trademarks

This equipment generates, uses and can radiate frequency energy and if
not installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested
and found to comply with the limits for a Class A computing device in accordance
with the specifications in Subpart J of Part 15 of FCC rules, which are designed to
provide reasonable protection against such interference when operated in a
commercial environment. Operation of this equipment in a residential area is
likely to cause interference, in which case the user at his own expense will be
Cet appareil respecte toutes les exigences du Réglement sur le matériel du
Please use the mailing address, phone and fax numbers and email address listed
required to take whatever measures may be required to correct the interference.
This Class A digital apparatus meets all requirements of the Canadian
Radio Frequency Interference Statement
below: GarrettCom, Inc.
47823 Westinghouse Dr. Fremont, CA 94539-7437
Interference-Causing Equipment Regulations.
Canada. Cet appareil est Classe A..



5.2 6KPM Module Description 41 5.2.1 6KP6-RJMST, Combo Module 41 5.2.1a 6KP6-RJ10ST, Combo Module 42 5.2.1b 6KP4-F10ST, Module 42 5.2.1c 6KP4-FLSTFX, Module 43 5.2.2. 6KP6-RJMSC FX-SC connector 43 5.2.3 6KP6-RJSSC connector 44 5.2.4 6KP6-RJSSCL single-mode connector 44 5.2.4a 6KP6-RJ10ST connector 45 5.2.5 6KP8-MTRJ, Form-factor 45 5.2.5a 6KP6-MT10ST, MTRJ Small-Form-Factor and port 46 5.2.6 6KP8-45MT, MTRJ Small-Form-Factor 46 5.2.7 6KP8-MLC, Form Factor 47 5.2.8 6KP8-45LC,LC small-form factor Connector 47 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port 48 5.2.10 New PoE(Power Inside), model PI6KP8-45RJ (MDIX), 8-port 49
5.2.12 6KP8-45-2MT, MTRJ Small-Form-Factor 50 5.2.12a 6KP8-45-2LC, single-mode FX , LC Small-Form-Factor 51 5.2.13 GBIC-SXSC Gigabit fiber(1000Mb), SC Connector 51
5.2.14 6KM-BLNK ...............................................................................52 6.0 TROUBLESHOOTING.......................................................................52
6.1 Before Calling for Assistance.............................................................53
6.2 When Calling for Assistance..............................................................53
6.3 Return Material Authorization (RMA) Procedure..............................54
6.4 Shipping and Packaging Information.................................................54
APPENDIX A: WARRANTY INFORMATION .........................................55
APPENDIX B : INTERNAL DC POWER SUPPLY OPTIONS.................55
APPENDIX C: INTERNAL DC DUAL-SOURCE POWER OPTION ......58

05/07: Minor updates to notes for Power Substations connections 04/06: minor updates as PoE modules option added on Sec 5.2.10/11 10/05: minor updates as MDIX support added on all RJ-45 port modules 01/05: minor updates and tweak on LC port modules 06/04: New port modules has been added and updates on Alarm contact 02/04: Minor update, and added Section 3.4.1, Alarm Contact option. 11/03 : Minor updates, Network standards & Console port pin Assign. 03/03 : Minor updates on power budget calculations , Gigabit fiber Rev D 10/02 : Updated the Rack Mount options and brackets, Section 3.3
Magnum 6K25’s MNS Software manual access information at sec 2.2.9
Appendix B and C with 24VDC and 125VDC Power Supply option.
Rev A 12/01 : This rev. is the initial release of the 6K25 manual.

GarrettCom, Inc. offers the premium-quality Magnum™ line of
INDUSTRIAL conectivity products with industry-standard functionality and
built-in fiber configurability. Magnum products are designed for use in
demanding Industrial Grade, Carrier Class, POWER UTILITY and OEM
4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto-negotiating
Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed and mixed-media
mP62 and P62F “Outdoor” Ethernet SwitchES, for temperature uncontrolled locations, 6 10/100
Personal Hubs, 10Mb series 8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-
6K-Series Managed Field Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports, mix-and
Media Converters, 10Mb and 100Mb series, All media combinations, incl. fiber ST, SC, mm.,
Personal Hubs, 100Mb or 10/100Mb 8-port, with 2 switched ports (1 fiber built in)
"DESIGNED AND MANUFACTURED IN THE USA"
The Magnum Line
applications where reliability is a primary consideration.
Stackable Concentrators, SNMP optional, 13-Ports
Dual Speed 8-port and 16-port, 10/100 auto-sensing HUBS
Repeater Port Modules (RPMs), 6 types for Ethernet media
Mixed-Media Fiber Hub, 16-port, 10/100 auto-sensing
The “X-line” of configurable MiXed Media products:
DX-Series Serial Device Routers, Ethernet and Serial
port and 4 or 5-Port Personal Hubs, w/ man. up-link sw.
match. Features SFF fiber and DC power in 1U units.
and 2 100Mb fiber ports, can be connected in strings
8 port dual-speed, Auto-negotiable with fiber option
Mini-Concentrators, 7 Ports, Repeaters, 2-Ports
COAX Transceivers, 10Mb series
types, full switching performance.
Personal Switches, 10/100Mb
full switching performance.
single mode

100BASE-FX, full-duplex, single-mode - 20.0 km (66K25 ft)
100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft)
Unshielded twisted pair - 100 m (328 ft)
10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)
10BASE-FL single-mode fiber optic - 10 km (32,810 ft)
10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)
100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft)
1000BASE-T (CAT5E or higher is recommended) - 100 m (328 ft) 1000BASE-SX, full-duplex, multi-mode(62.5µm cable) - 220m 1000BASE-SX, full-duplex, multi-mode(50µm cable) - 550m 1000BASE-LX, full-duplex, single-mode(62.5µm cable) -5Km
100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft)
100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)
Shielded twisted pair - 150 m (492 ft)
Shielded twisted pair - 150 m (492 ft)
15 µs + packet time (10 to 10 Mbps, and 10 to 100Mbps)
Maximum Standard Gigabit Ethernet Segment Lengths:
Maximum Standard Fast Ethernet Segment Lengths:
Network Standards and Compliance, hardware
Maximum 10 Mbps Ethernet Segment Lengths
duplex flow -control, non-blocking
Filtering / Forwarding Rate:
Ethernet:14,880 pps
Performance

DB-9 for RS-232 “ null-modem “ cable (sometimes called an Xmodem cable)
Fiber Port, ST-type (twist-lock):Fiber multi-mode, 10Mb 10BASE-FL
Fiber Port, MTRJ-type (plug-in):SFF Fiber multi-mode100BASE-FX
Fiber Port, SC-type (snap-in):Fiber optic multi-mode, 100BASE-FX
with adjacent manual ON-OFF switch (on AC models only)
Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX
UL 60950 “Component Parts” temp. rating: 130° F (55°C)
60 watts max (for a fully loaded fiber model) 35 watts for a fully-loaded copper only model
4.32cm H x 43.2cm W x 22.9cm D Cooling method: Fan cooled, @ 3@ 7 cfm ea.
Fiber Multi-mode connector types supported:
Fiber Port, 1000BASE-FX, GBIC modules
Fiber Port, 1000BASE-FX, GBIC modules
OFF = Half-Duplex Mode
Fiber Single-mode connector types:
DC Power Supply (Options)

are SPST NC Form-C relays, and an open condition indicates abnormal status. The
Dual Source options (for continuity of operation when either of the DC input sources
Alarm Contact option is offered as a configuration option. The two alarm contacts
For DC internal power supplies at –48VDC, 24VDC and 125VDC, including
The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45
ports., and eliminate the use of cross-over cable between the devices. Also port-
specific user settings (such as FDX or HDX, copper 10/100 speed) can be fixed
Hardware Alarm monitors internal power on the main board, and the Software
See also Note for Power Substations in Section 3.2.4, 3.6.1, and 5.2.9
IEEE 1613 Class 2 Environmental Standard for Electric Power Substations
IEC 61850 EMC and Operating Conditions Class C for Power Substations
UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class A
Alarm is activated by one or more user-selected software traps.
NEBS Level 3 and ETSI Certified for Carrier Central Offices
Email sales@GarrettCom.com for details.
are interrupted), see Appendices B and C.
Per-port MDI or MDIX on RJ-45
using software commands.
Agency Approvals

the power input connectors are in the rear. Two sets of LEDs (both rear and front) provide
May be configured with a selection of 10/100/1000 6K25 fiber and copper port
connector types, 25 total ports max. Wire speed filtering and forwarding across all ports,
6KP8-45-2MT “6+2” module, w/six RJ-45 ports and two 2km mm MTRJ connectors
6KP8-45-2SLC “6+2” module, w/six RJ-45 ports and two 100Mb 15km sgl. mode FX LC connectors
rack-mounting brackets. For licensed managed networks software, see MNS materials.
6KP4-FXST “2+2” 100Mb Fiber module, w/ four 100Mb 2km FX ST connectors
6KP8-45LC “4+4” module, w/four RJ-45 ports and four 2km mm LC connectors
802.3x flow control, 802.1p priority packet processing, self-learning 4K-node address table, large 240KB packet buffers for 10/100 and 120KB for 1000Mb. Plug-and-play
switching services, front-mounted LEDs, internal auto-ranging AC power supply, 19"
Each Magnum 6K25 and 6K25R base unit has four port module slots. The first
6KP4-FLSTFX “2+2” ST Fiber module, w/ two 100Mb & two 10Mb ports, 2km 6KP8-45MT “4+4” module, w/four RJ-45 ports and four 2km mm FX MT-RJ’s
three (A,B,C) may be one of the modules below, one (slot D) may only be a Gigabit
6KP4-F10ST “2+2” 10Mb Fiber module, w/ four 10Mb 2km FL ST connectors
6KP6-RJSSC “4+2” module, w/four RJ-45 ports and two 20km Sgl.m FX SC’s
6KP6-RJSSCL “4+2” module, w/four RJ-45 ports and two 40km Sgl.m FX SC’s
6KP6-MT10ST “4+2” module, w/four MTRJ ports and two 10Mb 2km FL ST’s 6KP6-RJ10ST “4+2” module, w/four RJ-45 ports and two 10Mb 2km FL ST ‘s
6KP8-MTRJ SFF Fiber module, w/eight 100Mb mm FX MT-RJ connectors
6KP8-SLC SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors
6KP8-RJ45 TP Module, w/eight 10/100Mbps auto-negotiating RJ-45 ports
6KP6-RJMST “4+2” module, w/four RJ-45 ports and two 2km mm FX SC’s
6KP6-RJMSC “4+2” module, w/four RJ-45 ports and two 2km mm FX ST‘s
6KP8-MLC SFF Fiber module, w/eight 100Mbps mm FX LC connectors
Magnum 6K25 Magnum 6K25 Managed Fiber Switch, base unit.
module. Select up to four port modules per base unit.
duplicate status data for viewing from either side.
1.2 Ordering Information
Magnum 6K25 Port Modules
Configuration Options:

GBPM-COTX One slot Gigabit 6K module for 6K25 Switches, uses one 6K25 slot and
GBIC-SXSC GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-SX
GBIC-LXSC40 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-ZX
GBIC-LXSC70 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-ZX
New P6KP8-RJ45 8 port PoE module for 6ks with 48vdc PS, w/eight PoE power source
New P6KP8-45MLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP8-45-2MT “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP8-452SLC “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
provides one GBIC open transceiver port for a user-selectable GBIC transceiver module
GBIC-LXSC10 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-
GBIC-LXSC25 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-
CONSOLE CBL Industry standard serial cable, DB-9 connectors for RS-232 “ null-
CONSOLE USB Console attachment cable, serial to USB, cable with one DB9 for the
New P6KP8-45MT “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP8-45SLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power
source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX MTRJ connectors
modem “ connection (sometimes called an Xmodem cable), used to connect a PC or a
10/100 auto-negotiating auto cross RJ-45 ports. New P6KP8-45RJ “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power
6K PoE Modules with 48VDC Pass-Through Configuration options: only one A, B or C module slot of 6K-Series switch with
GBIC transceiver module for use in GBPM-COTX, one LX port with mm SC fiber
GBIC-TP GBIC transceiver module for use in GBPM-xOTX, one 802.3ab
1000BASE-T port, RJ-45 connector 6KM-BLNK Blank cover for one 6K25 (A,B,or C) module slot opening in a
managed Switch and a USB interface for the USB connector to a PC.
48VDC power input may be configured with a PoE Modules
LX/LH port with 1310nm sgl. mode SC(10km) fiber connector
LX/LH port with 1310nm sgl. mode SC(25km) fiber connector
source and four 10/100 auto-negotiating auto cross RJ-45 ports
port with 1550nm, sgl. mode SC(40km) fiber connector
port with 1550nm, sgl. mode SC(70km) fiber connector
source and four 100 Mb 2km mm FX MTRJ connectors
For Gigabit module configuration options
source and four 100 Mb 2km mm FX LC connectors
source and four 100 Mb 15km sm FX LC connectors
character terminal to the Management port.
port with mm SC fiber connector
Magnum 6K25 or 6K25R chassis
connector

New PI6KP6-RJSSCL “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New PI6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four POE power
New P6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP6-RJSSCL “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New 6K125VDC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a
New PI6KP8-45MLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power
New PI6KP8-45SLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power
New PI6KP8-45-2MT “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New PI6KP8-452SLC “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New PI6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New PI6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New PI6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New P6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power
New 6KAC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a full-
New PI6KP8-45RJ “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power
New PI6KP8-45MT “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power
source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX MTRJ connectors
6K PoE Modules with 48VDC Power Inside NOTE: For configuring in 6K Switches having AC /125VDC power input
GarrettCom, Inc. reserves the right to change specifications, performance
48VDC power input may be configured with a PoE Modules
source and four 10/100 auto-negotiating auto cross RJ-45 ports
full-width rack-mount 6K switch with 125VDC power input.
characteristics and/or model offerings without notice.
source and four 100 Mb 2km mm FX MTRJ connectors
source and four 100 Mb 15km Sm FX LC connectors
source and two 100 Mb 2km mm FX ST connectors
source and two 100 Mb 2km mm FX SC connectors
source and two 100 Mb 20km sm FX SC connectors
source and two 100 Mb 40km sm FX SC connectors
source and four 100 Mb 2km mm FX LC connectors
source and four 100 Mb 15km sm FX LC connectors
source and four 100 Mb 15km Sm FX LC connectors
source and two 100 Mb 2km mm FX ST connectors
source and two 100 Mb 2km mm FX SC connectors
source and two 100 Mb 20km sm FX SC connectors
source and two 100 Mb 40km sm FX SC connectors
width rack-mount 6K switch with AC power input.
source and two 10 Mb 2km sm FL ST connectors
source and two 10 Mb 2km sm FL ST connectors

In the event there are items missing or damaged, contact the party from whom
product; notify the carrier of any damage that you believe occurred during shipment or
delivery. Inspect the contents of this package for any signs of damage and ensure that
Remove the items from the shipping container. Be sure to keep the shipping
shipping container if possible. Refer to Section 6, Troubleshooting, for specific return
Examine the shipping container for obvious damage prior to installing this
container should you need to re-ship the unit at a later date. To validate the product
you purchased the product. If the unit needs to be returned, please use the original
warranty, please complete and return the enclosed Product Registration Card to
(configured with user-selected port module options)
1 Magnum 6K25 Managed Fiber Switch, base unit
1 AC Power Cord (U.S. and other 115 VAC only)
1 Set of metal “Ears” for 19” rack mounting
1 Installation and User Guide (this manual)
1 Product Registration Card
This package should contain:
GarrettCom, Inc. as soon as possible.
the items listed below are included.
procedures.

The Magnum 6K25 has up to 25 ports capacity, all of which may be configured
Gigabit ports. It also allows a mix of 10/100Mb RJ-45 (copper) ports and a fiber Gigabit
application and Ethernet cabling requirements. Even evolving mixed-media requirements
LEDs in the front and the power input and management console connector in the rear) or
The Magnum Managed Fiber Switch boosts the performance of large Ethernet
LANs, typically serving as a “backbone” switch. It has the flexibility to handle a mix of
as fiber ports, but still offers a space-saving rack-mount chassis that is only 1U (1.70in.
port in the same unit. This flexibility is achieved via a family of 6K25 port modules for
selections using GBICs. These modules can be factory configured in a base chassis unit
power –inside PoE modules and allows the users to select a wide option of combo PoE
modules to support 802.3af pd devices. See details in sec 5.2.10 and 5.2.11. The Power
wireless access points, IP phones) that comply with the IEEE 802.3af PoE standard. The
duty applications. The chassis mounting rack style may be “regular” (with the ports and
performance switching services for both “smooth” streaming and “bursty” data traffic.
for 10Mb and 100Mb fiber and copper as well as Gigabit ports can be handled by the
both fiber and twisted-pair switched ports along with Gigabit backbone port options.
(or may be changed in the field by trained technicians) to adapt the unit to the user’s
Sourcing Equipment (PSE), and are fully compatible with Powered Devices (PD)(e.g
PoE switch ports have an auto-sensing algorithm, so that they provide power only to
802.3af, PoE end devices. PoE is managed by a multi-stage handshake to protect
The packaging and power-input options target the Magnum 6K25 at heavy-
or 4.32cm) high. The “mixed-media” capability allows user selection of all popular
copper and fiber-built-in (emphasizing Small Form Factor fiber for high fiber port
The 6K25 managed switches also provides PoE option via Power-pass-through and
discontinue supplying power when the PoE powered devices are disconnected, and
flavors of fiber port connectors and modes, including even 10Mb fiber along with
density), 6-port modules for fiber and RJ-45 combinations, and 1Gb port module
support the 802.3af PoE PSE standard for over-current protection, under-current
equipment from damage and to manage power budgets.The PoE ports will
Industry-standard IEEE 802.1p QOS prioritization is included, providing high
detection, and fault protection.
Magnum 6K25 product.

accommodated include standard 19” RETMA, ETSI, and 23” Telco. Input power may be
performance plug-and-play hardware operation, 802.1p packet prioritization in hardware,
port slots (A, B, and C) and one Gb-only slot (D) for configuration flexibility. Slots A, B
and C may be configured with any of a large selection of fiber and copper port types and
Designed for use in network traffic centers, the Magnum 6K25 Managed Fiber
The Magnum 6K25 is a 19” rack-mountable Ethernet Switch with three eight-
even one Gb port. Slot D may be configured with a Gb module that accepts GBICs. The
are normally factory installed, but may be changed or added in the field. (See Section 5)
Status LEDs are part of each port module and are viewable when connecting
“Reverse” rack-mount models, there is a duplicate set of LEDs on the other (front) side
“Reverse” (with the ports and LEDs and the power-input and the management console
learned, maintained and aged out, adapting the switching services to network changes.
and industry-standard managed networks software functionality, all in convenient 1U
combinations of types, typically eight ports per module, but sometimes 6 or 4 ports or
variety of applications, especially using fiber media. The Magnum 6K25 port modules

port types configurable using the 4 slots allows the 6K25 to efficiently serve a large
Switches are easy to install and use. Addresses of attached nodes are automatically
LEDs provide status information on each port. The Magnum 6K25 provides high
the Ethernet media. A “regular” rack-mount 6K25 is shown in Figure 2.2.1a. On
connector all in the rear and a duplicate set of LEDs in the front). Rack widths
AC, or –48VDC for Telco environments, or 24VDC for Industrial applications.
rack-mount packages.

speed (100Mb), mode, and connector type. Models are available with Small Form Factor
(SFF) are multi-mode MT-RJ or LC-
default) to operate in full-duplex mode for best fiber distance and performance. Using the
6K8-MTRJ (to the left) and
set-up of the software (See Magnum 6K25 MNS Software Manual) for the flexibility to
There are three LED’s per fiber port. The Link (LK) LED indicates “ready for
Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK)
In an eight-port SFF fiber port module, all of the fiber ports are of the same
type connectors, and single-mode
The 100Mb fiber eight-
6K25’s normally are set (factory
6K25’s MNS software, the user may select full- or half-duplex mode per-port through
operation” on that port when lit, the F/H LED indicates operation in full-duplex mode
indicator for that port must be ON (indicating there is a powered-up device at the other
for normal status viewing from that direction. Of course, with management, the port
6K8-MLC or -SLC (below)
port modules for the Magnum
when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving
end of the cable) in order for a LK LED to provide valid indications of operating
Fig.2.2.2 :
LC-type connectors.
adapt to any FDX or HDX type of Fast Ethernet devices).
F/H
ACT
ACT
ACT
F/H
ACT
F/H
ACT
F/H
ACT
F/H
F/H
F/H
ACT
F/H
status data is also available in software.
1 3 5 7
2 4 6 8 LK LK LK LK
2 4 6 8 LK LK LK L
2 4 6 8 LK LK LK L
1 3 5 7
conditions on that port.
ACT
F/H
F/H
ACT
F/H
ACT
F/H
AC
F/H
AC
AC
F/H
AC
F/H
SFF Fiber Port · Modules,


(See Section 4.3 for auto-negotiation and MDIX details). The auto-crossover feature will
port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that port
into an RJ-45 port and the Link (LK) indicator for that port must be ON (indicating there
crossover(MDIX) for operation at 10 or 100Mb speed in full- or half-duplex mode, i.e.,
each independently selects a mode and speed to match the device at the other end of the
On the model 6K8-RJ45 module, there are four LEDs for each port, two in the
connector and two separate. The LK (Link) LED indicates “ready for operation” on that
Using the 6K8-Series (MNS-6K) management software, the user may disable
auto-negotiation and fix the desired operation of each RJ-45 port. User may select 10Mb
when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10 Mb

is a powered-up device at the other end of the cable) in order for a LK LED to provide
or 100Mb speed and full- or half-duplex mode per-port as per user requirement. (See
automatically determine the other side of connection to make the connection, and
valid indications of operating conditions on that port.
Magnum MNS-6K Software Manual for details info.).
eliminate the need of cross-over cable.
ports. The 10/100Mb switched
way auto-negotiating, and auto-
speed when OFF (when auto-
operation and OFF to indicate
pair cable must be connected
Copper port module, model
ports normally (as a default
setting) are independently N-
negotiation is not disabled).
The FDX/HDX LED is ON
half-duplex mode. A twisted
twisted pair cable.

802.3af PoE pd devices. The 4-RJ45 POE
except they have capability of providing power on each port to power up the PD devices,
standard. The Power Pass-
totally dependent upon the
Maxm. one PoE modules
A, B or C slot of any 6K s
The PoE modules are also
The New PoE RJ-45 ports act similar to regular RJ-45 ports, except they have
standard. Only 4 x RJ-
mounted 6K-unit. The
option to support four
PoE LED is ON when connected properly to a 803.af compliant PD device on that port.
When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data
LINK and ACTIVITY LEDS are combined on the PoE modules into one LED
The PoE (Power-pass-through) RJ-45 ports act similar to regular RJ-45 ports,
per the IEEE802.3af PoE
through PoE modules are
power supply to support
ports. Each port requires
atleast 15watts to power
can be configured in the
with -48vdc power input.
available with mix –n-match with fiber modules. Please check the ordering information
2.2.4 New PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-port
regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the
2.2.5 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8- port
up the PoE PD devices.
IEEE802.3af PoE
45 (10/100) ports maxm. support
option in one rack
module are also available with mix –n-match with fiber modules. Please check the
The LEDs on 6KP8-RJ45- PoE module are slightly different compared to
capability of providing power on each port to power up the PD devices, per the
ordering information Sec.1.2. for all the various PI6K PoE modules option.

3 F/H POE
that is marked as LINK/ACT, as shown in the diagram.
2 1 3 5
4 FULL/HALF
2 4 6 F/ H POE
8 Port@ 10/100Mb Copper ports
traffic is not affected by PoE.
8 Port@ 10/100Mb Copper ports
6KP8 -45RJ
LINK LK / ACT 2

The four RJ-45 ports operate just like the 8-port copper module with auto-cross
On Magnum “4+2” Combo modules, there are four LED’s for each RJ-45 port,
which indicate status the same as described for the 6K8-RJ45 in Section 2.2.3 above. The
2@10Mb fiber mm ST ports, and with
4@ RJ45 10/100 copper and 2@10Mb
PoE LED is ON when connected properly to a 803.af compliant PD device on that port.
When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data
LINK and ACTIVITY LEDS are combined on the PoE modules into one LED
four 10/100 switched RJ-45 copper ports and two 100Mb switched multi-mode fiber ST,
(MDIX) feature to eliminate the use of cross-over cable, and the two fiber ports operate
at 100Mbps full-duplex (default). User mode control per port through the MNS software
fiber port’s LEDs indicate status the same way as described for the SFF fiber modules in
4@ MTRJ 100Mb mm SFF fiber and
4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber and the RJ-45 half of
regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the
The combo six-port modules are combinations of copper and fiber media, available as
SC or single mode SC or Long Reach SC ports. For ports numbering, ports 1,3,5,7 are
The Magnum Combo six-
port modules are also available with
the module is as described for those port types above. For detailed information about
The LEDs on 6KP8-RJ45- PoE module are slightly different compared to
Section 2.2.2 above. Color-coding on the panel of the module shows which LEDs
fiber mm ST ports. The
copper, ports 2 and 6 are fiber, ports 4 and 8 are not present.
10Mb mm ST fiber half of the module, see Section 2.2.5.
that is marked as LINK/ACT, as shown in the diagram.
Sec.1.2 for all the various P6K PoE modules option.
10/100 LK
F/H ACT
2 6 TX RX TX LK RX LK
1 3 5 7
traffic is not affected by PoE.
belong to which port.
F/H
is also the same.
F/H

1@ 1000Mb Fiber SC + 2@ 100Mb SC
six-port modules are also available
copper and 2@10Mb fiber mm ST
and the RJ-45 half of the module is as described for those port types above. For detailed
G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber
with 4@ MTRJ 100Mb mm SFF
fiber and 2@10Mb fiber mm ST
ports, and with 4@ RJ45 10/100
media converter or almost any other device with a 10Mb fiber Ethernet port. User mode
control per port through the MNS software is the same as the other 6K25 modules. The
The Magnum 6K25 offered a wide option Gigabit speed with multiple choice
for the modular slot. While up to two Gigabit modules (maxm.) can be configured in the
configuration. The Giga port has been offered
ports. The 4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber
information about 10Mb mm ST fiber half of the module, please check section 2.2.5.
present, ports 3, 4. 7, 8 are not present. The default setup on the 10Mb fiber module is
fiber ports support fiber cabling distances according to the 10BASE-FL standard, i.e.,
modular slot. The Gigabit port option for the modular slot comes in couple of different
as single Gigabit module comes in flavor of
The 4port @10Mb ST fiber modules behave the same as the 8@100Mb ST
half-duplex, which allows the Magnum 6K25 Switch to connect to any 10Mb hub or
fiber modules except for the 10Mb speed. For ports numbering, ports 1, 2, 5, 6 are
2km distance for multi-mode fiber. (Single-mode for up to 10Km distance may be
ports) as shown below .


available as a special order configuration).
ACT
F/
TX RX LK
TX RX L
ACT
ACT
F/
F/
The Magnum Combo

6K25 can do its part to prevent any QOS degradation while it is handling Ethernet traffic
The Magnum 6K25 switching hardware supports the IEEE 802.1p standard and
CRC, i.e., are good packets. This eliminates the propagation of bad packets, enabling all
The 6K25 Modules provide a GBIC opening for insertion of industry-standard
module on the Gigabit -SX and Gigabit-LX 1@ 1000Mb Fiber SC + 4@10/ 100Mb
There are two LEDs mounted on each Gigabit port module. The Gigabit fiber
users from datagram paths that go all across a network. As a LAN device, the Magnum
packets according to the 802.1p standard. In addition to hardware support for QOS, the
GBICs to provide Gigabit (Gb) media flexibility. GBIC models are available for both
multi-mode (550m) and single-mode (10, 25, 40, 70)km fiber options, and for Gigabit
fulfills its role in support of QOS, giving packet processing priority to priority tagged
Magnum 6K25’s are store-and-forward switches. Each frame (or packet) is
port is by default configured at AUTO mode, and can be fix at 1000Mbps speed full-
Quality of Service means providing consistent predictable data delivery to
MNS software (R2) supports two priority queues that can be shared across the eight
levels of defined packet priorities for application-specific priority control by the user
technique ensures that all forwarded frames are of a valid length and have the correct
1 3 5 7
loaded into the Switch’s memory and inspected before forwarding can occur. This
duplex mode at any times and has LEDs that indicate LK (Link status) and ACT
copper as well, with new models appearing often.
transceivers are compatible with the IEEE 802.3z Gigabit standards.
ACT
F/
2.2.9 Packet Prioritization, 802.1p QOS
2.2.10 Frame Buffering and Flow Control
modules on the Magnum 6K25s are normally
performance. The 1000Mbps SC fiber-optic
The 1000Mb Gigabit fiber-port
(receiving activity) on that port when lit.
set (factory default) to operate at AUTO
through software configuration settings.
mode for best fiber distance and
through its ports and buffers.

When the Magnum 6K25 Switch detects that its free buffer queue space is low,
Series MNS Software User guide in pdf format, a separate document normally accessed
All MNS-6K software information, including new releases and upgrades related to MNS-
"express") impose minimal frame latency, they will also permit bad frames to propagate
out to the Ethernet segments connected. The "cut-through" technique permits collision
fragment frames (which are a result of late collisions) to be forwarded which add to the
network traffic. Since there is no way to filter frames with a bad CRC (the entire frame
collisions and bad packets are more likely when traffic is heavy, the result of store-and-
forward operation is that more bandwidth is available for good packets when the traffic
the Switch sends industry standard (full-duplex only) PAUSE packets out to the devices
stop sending traffic, which allows a traffic catch-up to occur without dropping packets.
sending packets to cause “flow control”. This tells the sending devices to temporarily
control mechanism (when operating at half-duplex only). When the Switch detects that
which allows to configure the Magnum 6Ks as a Managed Switch and other Software
its free buffer queue space is low, the Switch prevents more frames from entering by
forcing a collision signal on all receiving half-duplex ports in order to stop incoming
Magnum 6K25-Series’s come with licensed MNS-6K Firmware (Rel 3.2),
enabled features. For additional information about MNS-6K, see the Magnum 6K25-
must be present in order for CRC to be calculated), the result of indiscriminate cut-
through forwarding is greater traffic congestion, especially at peak activity. Since
Then, normal packet buffering and processing resumes. This flow-control sequence
Another feature implemented in Magnum 6K25 Switches is a collision-based flow-
While other switching technologies (such as "cut-through" or
Alternatively, for documentation and latest information, or needed
6K software, can be accessed and download from GarrettCom’s FTP site.
occurs in a small fraction of a second and is transparent to an observer.
of the available bandwidth to be used for valid information.
via your web-browser, at ftp://ftp.garrettcom.com/
or FTP client program by ftp.GarrettCom.com using
load is greatest.
traffic.

www.GarrettCom.com/techsupport/index.htm#software and look for Magnum
Magnum 6K25 Switches provide non-blocking (all ports can run at full speed at once)
Gigabit ports for backbone connections, where managed network services are desired.
Magnum 6K25 Managed Fiber Switches are designed to naturally include fiber ports,
The 1U Magnum 6K25 chassis has 4 slots for port configurations. Family of 4, 6 or 8
port modules allow the user to select the desired mix of port types & speeds. The port
The standard rack mounting provides Ethernet ports and status LEDs in front, service
applications, models with –48VDC or 24VDC or 125VDC are available. Dual Source
Heavy-duty design for Industrial Ethernet and extended temperature operation.
Fiber ports take more power than copper ports, but the Magnum 6K25 design provides
performance with standard Managed Networks Software (MNS-6K) included. They
priority to priority tagged packets according to the IEEE 802.1p standard. For port-
and application-specific priorities, the QoS software may be configured by the user.
for this with heavy-duty components. The ambient temperature can be up to 55°C.
allow the basic and advanced info about the Magnum MNS-6K management software
Modular design for port flexibility, in a 1U space-saving rack-mount package
modules are normally factory installed and tested, but may be changed in the field.
Standard 19’ rack mount brackets are included, with ETSI and 23” Telco optional.
Standard AC power input is IEC plug, auto-ranging for worldwide use. For special
Magnum MNS-6K Operator Training – This interactive training software
are typically used in LAN traffic centers with 16 to 24 100Mb ports and one or 2
The Magnum 6K25 switching hardware supports QoS, giving packet processing
and support mixes of multi-mode and single-mode; 10 Mb, 100Mb and 1000Mb
Rack-mounting may be standard or “reverse”, 19 inch or ETSI or 23” Telco
Standard AC power input, -48VDC or 24VDC or 125VDC input is optional
connectors. RJ-45 10/100 ports can also be configured in the mix of port types.
connections (power input and management console) in the rear. “Reverse” rack
mounting provides status LEDs in front and all cabling connections in the rear.
speed; full-and half-duplex; classic Small Form Factor (SFF) and GBIC fiber
DC input can also be selected and configured on the DC power input models.
Switching services includes 802.1p QoS packet prioritization
Managed switching for high performance Ethernet LANs
or email: support@GarrettCom.com for further information.
2.3 Features and Benefits
and a useful tool for first time user.
MNS-6K info..
Features Fiber-Built-In

cross-over cable. The Auto-MDIX capability allow the Magnum 6K25 to cascade any
The RJ-45 modules are equipped with MDI/MDIX capability to eliminate the use of
The 6K25 has been tested and certified for NEBS and ETSI. Request test reports.
MNS-6K licensed Network Management Software included, S-Ring optional
Release 2.3 (summer ’03) includes SNMP Switch Management with secure access
control, RMON, CLI, Port Security; Port Mirroring; Port Settings Control; Telnet,
TFTP, FTP support, Spanning Tree Protocol, RSTP, Web-based, multi-level QoS,
Port- and tag-based VLANs, GVRP, IGMP Snooping, SNMPc GUI support; Event
Log; SNTP client for time-of-day; BootP and DHCP client for IP configuring, and
password security. Supplied and updated via Internet and GCI FTP Server.
Hub, switches or media converters with normal straight cable.
RJ-45 ports are MDI/MDIX supported
NEBS and ETSI tested and certified

traffic centers require Gb backbone services. The performance characteristic of the 6K25
Ethernet network center. A secure VLAN-enabled network is simply an administratively
R&D, and Marketing need to keep a secure LAN, the 6K25’s VLAN feature will prevent
Magnum 6K25 Fiber Switches offer high performance and modularity. They
provide the flexibility of 100Mbps fiber and copper ports as well as Gigabit ports, with
industry-standard LAN management software. Magnum 6K25 Switches are easily used
Switches enables them to inter-connect a series of subnets (one subnet per 6K25 Switch
nodes are in which broadcast domains by setting membership profiles for each of them.
Full-duplex future proof fiber media can easily connect long distance subnets
in a variety of applications including MANs (metropolitan area networks) client/server
computing, secure VLAN- performance upgrades to departmental networks, and LAN
port) in a LAN traffic center. The subnet connections may be via fiber or twisted pair
Equipped with lots of useful features, the Magnum 6K25 Managed switch is
configured broadcast domain. The network administrator determines which ports and
controlled. The Managed Magnum 6K25 equipped with VLANs capability is ideal for
choice for use in applications with LAN connections to an organization’s multiple site
supported by the Magnum 6K25 Switch. A main NT-server in a secure area protected
from earthquake or fire hazards can be connected to the full duplex Gigabit Fiber port.
The Magnum 6K25’s VLAN capability can be developed in several types of Virtual
In an office environment where departments such as Finance, Engineering,
traffic cross-over among domains, and thus from keep sensitive data and information
The mixed-media capability is ideal for upgrading existing Ethernet LAN
networks where existing cabling must be accommodated. The fiber-built-in media
capability is ideal for integrating future-proof fiber cabling into the LAN structure.
The modularity of the 6K25 Managed Fiber Switch makes it an attractive
offices. The different offices can be easily connected together with the Fiber ports
able to handle a VLAN application and provide a security and performance in an
any application where a secure VLAN to multiple departments is needed.
cabling, 100Mbps or 10 Mbps speed, and full-or half-duplex mode.
LANs, such as Port-based VLANs, or Tag-based VLANs.

capability of the Magnum 6K25 Switch helps create a database of all the network subnets
backbone for a diversified network with multiple subnets. The back bone consists of high
bandwidth Gigabit-enabled data-mining server for the vital database located in a separate
user-configurable Magnum 6K25 provides an extra boost to the network requirements by
The 6K25 Managed Fiber Switch with mixed-media flexibility allows the users
secured building. The copper ports are required for multiple subnets inside the building.
The entire spread network will be manageable to provide easy, detectable, uninterrupted
Example 2. In another application, a managed switch is needed to provide an Ethernet
provide secure long distance LAN connections. The entire network is sharing a higher
The Magnum 6K25 Managed Fiber Switch equipped with the mix of copper
and fiber ports provides an economical and seamless solution to the requirements. The
1000Mb. The user can utilize the SNMP feature equipped with VLAN, RMON, SNTP
speed LAN segments supported by 100Mbps full-duplex future-proof fiber media to
providing copper/fiber media along with the higher bandwidth support of 10/100 and
support future expansion as the network evolves. The Gigabit port option boosts the
and other standard managed LAN features to provide a secure and stable network.
more than one configuration alternative. The user has an advantage by fulfilling the
present requirements as well as benefiting from the multiple choices of modules to
and provide a stable secure network to all applications. The SNMP management
bandwidth for high speed to support the peak traffic and minimize congestion.
support through a viewable SNMP monitor.
to easily manage the network.

1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment
2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate airflow must be maintained for proper and
3.) If the equipment is mounted in an enclosed or multiple rack system, placement of the equipment must not overload or load
4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent
The location of a Magnum 6K25 Switch is dependent on the physical layout of
compact size allows it to be easily placed in an office or lab area, and it can also be either

5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and
7.) CB-Circuit breakers of 10Amps should be shown on top of the Rack.
the network. Typically the Switch is placed in a central wiring location where groups of
because they have rubber feet they can also be installed on a shelf or table top unit. The
This section describes installation of the Magnum 6K25 Switches, as well as
network devices need to be connected in order to communicate with each other. These
Before installing the equipment, it is necessary to take the
6.) 24vdc, -48vdc, and 125vdc must be installed in restricted access locations.
Switches are typically rack mounted in a wiring closet see Section 3.3.2 below), but
overloading of the building/s electrical circuits.
Locate an AC receptacle that is within six feet
monitor the status LEDs. Keep an open area around the
left side, while the unit is in operation. See figure below.
rugged metal case of the Magnum 6K25 will normally
protect it from accidental damage in a lab or workplace
setting. Maintain an open view of the front to visually
unit so that cooling can occur from the small fan on the
(2 meters) of the intended Magnum 6K25 site. The
must be less than or equal to 500C.
shelf of wall-mounted (see Section 3.3.1 below).
connection of the various Ethernet media types.
uncompromised earthing path.
unevenly the rack system.
following precautions:
safe operation.

individually selected and configured per-port. See Section 2.4 for a description
10BASE-T and 100BASE-TX twisted pair 100m (328 ft) 6K8-RJ45
connectors. This procedure applies to ports using a 6K25 module, MST-type port.
The Magnum 6K25 Switches are specifically designed to support all
dampened in alcohol. Make certain the connectors are clean before connecting.
connection has been established at both ends (and when power is ON in
The following procedure applies to installations using a PM with ST-type fiber
Receive (RX) port of the remote device. Begin with the color-coded strand of
(TX) port of the remote device. Use the non-color coded fiber strand for this.
improper cable polarity. Swap the fiber cables at the PM connector to
The various media types supported along with the corresponding IEEE
the unit). If LINK is not lit after cable connection, the normal cause is
accomplished by using a family of different port Modules which can be
small form factor mm1 Fiber 2.0km (6,562 ft) 6K8-MTRJ, -MLC small form factor sgl.m1 Fiber 15 km 6KP8- SLC
bands at regular intervals; you must use the color-coded strand on the
IEEE Standard Media Type Max. Distance Port Module
100BASE-FX mm1 Fiber 2.0km (6,562 ft) 6K6-MSC, -MST
standard Ethernet media types within a single Switch unit. This is
sgl.m2 Fiber 5Km GBIC-LXSC
1 mm = multi-mode 2 sgl.m = single-mode 3.2.1 Connecting Fiber Optic ST-type, “twist-lock”
sgl.m2 Fiber 18.0km (95K ft) SSC, SSCL
802.3 and 802.3u standards and connector types are as follows:
100BASE-FX mm1 Fiber 220m ( ft) GBIC-SXSC
associated ports at each end of the fiber optic segment.
the cable for this first TX-to-RX connection.
remedy this situation.
of the PMs.
Fiber:

The following procedure applies to installations using a PM with SC-type fiber
(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx
fiber allows full bandwidth at longer distances, and may be used to connect 10 Mb nodes
mixed-speed network, since dual-speed ports are auto-sensing for either 10 and
connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable
The RJ-45 ports of the Magnum 6K25 can be connected to the following two
100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100
The following procedure describes how to connect a 10BASE-T or 100BASE-
are the diameters of the core and the core plus the cladding respectively). Single-mode
3.2.4 Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or Shielded)
Twisted Pair (CAT 3, 4, 5) 10BASE-T RJ-45
TX twisted pair segment to the RJ-45 port. The procedure is the same for both
When connecting fiber media to SC connectors, simply snap on the two square male
When using single-mode fiber cable, be sure to use single-mode fiber port
The same procedures as for multi-mode fiber applies to single-mode fiber
Twisted Pair (CAT 5) 100BASE-TX RJ-45
and 100Mb) be used whenever possible in order to provide flexibility in a
Media IEEE Standard Connector
shielded, either unshielded or shielded cables and wiring may be used.
connectors into the SC female jacks of the 6KPM until it clicks and secures.
3.2.2 Connecting Fiber Optic SC-type, "Snap-In"
connectors. Follow the steps listed in Section 3.2.2 above.
connectors, i.e., using 6K-MSC, 6K-SSC single-mode.
unshielded and shielded twisted pair cables.
up to 10 Km apart, or 18Km with the 6K-SSC.
100Mb/s.
meters (328 ft).
established


could produce kigh (greater than 2500V ) levels of ground potential rise (GPR)
during line-to-ground fault conditions. The 6K25 passes the 1613specifications
either case, the maximum distance for unshielded twisted pair cabling is 100 meters (328
Mb and 1000Mb) be used whenever possible in order to provide flexibility in a
The Magnum 6K25 Manageable Switches can be easily mounted on a table-top
for zero packet loss with fiber ports & with RJ45 ports used as indicated here.
The RJ-45 Gigabit ports of the Magnum 6K25 can be connected to the media
The following procedure describes how to connect a 1000BASE-T twisted pair segment
telecommunication multiplexers installed in close proximity (i.e., less than 2
types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)
balanced cable is recommended to use when making 1000BASE-TX connections. In
to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted
or any suitable horizontal surface, and has four rubber feet to provide stability without
substation applications to interface to field devices across distances which
balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)
advises that, for substation applications, the RJ-45 ports are intended for
3.2.5 Connecting Twisted Pair (CAT5E or better, Unshielded or Shielded)
meters or 6.5ft) to the 6K25. It is not recommended to use these ports in
ft). See Section 4.3 for manual Up-Link switch on port 1 of copper port modules.
Media IEEE Standard Connector
connectivity to other communication equipment such as routers or
Twisted Pair (CAT 5E) 1000BASE-T RJ-45
10/100 LK 2 4 6 8 F/ H ACT
1 3 5 7
F/H ACT
2 6 TX RX TX LK RX LK
F/H ACT
F/H
ACT
Magnum 6K25 1 3 5 7 10/100 LK
10/100 LK 2 4 6 8 F/ H ACT
3.3 Table-Top or Shelf Mounting
cables and wiring may be used.
mixed-speed network.
pair cables.
surfaces.

3.3.1 Rack-mounting (for 19” RETMA racks), regular Magnum 6K25s Installation of a Magnum 6K25 Fiber Switch in a 19” rack is a simple
mounting purposes. The 23” and the ETSI brackets are mainly used for larger equipment
mounted in various ways. The same holes fit all three types (19”, ETSI, 23”) of brackets.
attached flush with the front, or attached in the center for a set-back mounting which may
The optional 23” brackets and the ETSI (21”) brackets each come as a pair in a
LED status indicators should be in plain view and easy to read. Rack-mount installation
6K25 unit). These brackets attach to the front sides of the Switch (regular package, i.e., not the Reverse version), which is then typically fastened into a standard 19” RETMA
also available (optional) for rack-mounting of Magnum 6K25 Switches. These brackets
The bracket mounting holes in the sides of the Magnum 6K25 permits it to be
procedure. The units are 1U (1.70”) high. When properly installed, the front-mounted
The 23” brackets and the ETSI (European metric, approx. 21”) brackets are
package, along with the necessary screws for attaching the brackets to the sides of the
requires special 19” rack-mounted brackets and screws (included with each Magnum
are popular in the Telco industry where they are a standard for Central Office rack-
The mounting for the 23” is illustrated in Figure 3.3.1 below. The brackets may be
assemblies in rack-mounting frames where the rack-mount equipment is typically
Fig 3.3.1 Mountings for Magnum 6K25 units rack-mounted in a frame

Magnum Switch unit. They must be ordered as line items.
10/100 L 2 4 6 8 F/ H AC
10/100 L 2 4 6 8 F/ H AC
10/100 L 2 4 6 8 F/ H AC
10/100 L 2 4 6 8 F/ H AC
accessed in operation from both sides.
10/100 L 2 4 6 8 F/ H AC
10/100 L 2 4 6 8 F/ H AC
10/100 L 2 4 6 8 F/ H AC
reduce cabling torque.
rack as shown here.

With each bracket type, there are three different mounting options is shown in
Fig. 3.3.2. The case of the Magnum 6K25 has mounting holes prepared for each of the
mounting arrangements. Users may choose the mounting arrangement most suitable for
3.3.2 Rack-mounting, Reverse version of the Magnum 6K25s The optional Reverse Magnum 6K25 Model has all of the cabling (Ethernet
cabling, power cabling and console port cabling) connectors in the rear, and the status
LEDs in the front. The status LEDs that are co-incident with the ports are still present
there, and a second or dual set of LEDs are used for status visibility in the front of the
frame or the 23” frame or ETSI (21”) frame. The 19” brackets are included with each
The Magnum 6K25 Switches incorporate an internal universal power supply
manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard power
The auto-ranging power supply supports installation environments where the
There are three options of brackets available to mount in the standard 19”
and have a recessed male IEC connector for the AC power cord at the left-rear. A
cord is supplied with each unit shipped within the United States and Canada.
Fig 3.3.2 Reverse Magnum 6K25 units, rack-mounted in a frame
3.4 Powering the Magnum Managed Fiber Switch

unit, the other two may be purchased if desired.
unit, showing the same data.
their installation.

AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz.
connected or disconnected without concern for AC power-related problems or damage to
3.4.1 Alarm Contacts for monitoring internal power, and Software Traps The Alarm Contacts feature, optional on Magnum 6K25’s, provides two
The AC or DC power input connection is in the same panel. A manual On-Off Switch for
power to the unit is not available on 6K25 units with the Alarm Contacts option, as these
enabled, the Form C Normally Closed (NC) contact is held close during normal software
The second (bottom position) NC Alarm Contact is held close when there is
power on the main board inside of the 6K25. This provides a “Hardware Alarm” because
The 25-port units will consume over 20 watts of power typically. When connecting the
The first NC Alarm Contact (top position) is a “Software Alarm”, operated
feature with a software configuration command if desired. When the Software Alarm is
Ethernet cabling, there is no need to power down the unit. Individual segments can be
Power supply options are available to suit the 6K25 Switches to special high-
See the Appendices of this manual for more details. Use an RFQ for other variations.
Form C Normally Closed (NC) contacts to which the user can attach two sets of status
monitoring wires at the green terminal block. When this option is present, the terminal
operation. A user-defined software malfunction, such as an SNMP Trap or a Software
The Magnum 6K25 Switches are normally received from the factory with all
block for Alarm Contacts is part of the Power Input panel in the Magnum 6K25 case.
Security violation or an S-Ring Fault, causes the contact to open and thus trigger an
the NC contacts will open when internal power is lost, either from an external power
availability communications and/or heavy industrial-grade applications, including:
by user settings in the MNS-6K software. The user can disable the Software Alarm
down condition or by the failure of the power supply inside of the Magnum 6K25
reference the Magnum MNS-6K Software User Manual. (Chapter 19th).
* -48VDC, 24VDC and 125VDC with dual-source DC input,
* -48VDC, 24VDC and 125VDC with single DC input,
two features occupy the same space in the case.
Switch. Useful info. about Alarm contacts:
alarm in the user’s monitoring system
the unit.

contains (Daughterboard (Bigger) and Granddaughter board (smaller), three 5/8
for an available front-mounted slot must be removed. The following procedure describes
Front panel face plate package. The Front panel faceplate package includes 3
mixed with other Fiber combo 6KPM card packages. Always install the PM
assembled together with the help of 22 Philips-head screws. There are 7 screws located
on the front-bottom and rear-top of the unit and four screws each on the sides. Remove
these screws. Once these are removed, the top cover is easily lifted off the chassis base.
required 6KPM modules installed. There may be situations where 6KPM cards need to
be added or replaced. In cases where additional 6KPM cards are needed, the faceplate
properly. Each 6KPM Card package except the Gigabit, for field installation
stand offs for Granddaughter board, six #4-40 Pan-Head screws along with
Granddaughter board. The copper 6KPM card should not work properly if
The Magnum 6K25 chassis are combined with top and bottom parts and
equipment) are sensitive to static discharge. Use proper ESD measures when
When the chassis top cover has been removed, the interior of the unit is exposed.
Failure to do so may result in damage to the unit
from the chassis before attempting to remove
for all powers single or dual, is unplugged
Be sure the power cord and connections
and/or replace any PM cards.
module separately one by one to avoid the mixing.
and will void the warranty.
retainer brackets and six #2-56 flat head screws.
handling port modules.
this operation.

Looking down into the Magnum 6K25 unit, notice that there are individual PM
installation spaces and female latch(white) connectors provided on the main board along
position, but unscrew only four of the screws as shown in Fig. below. These screws are
Up to four front-mounted 6KPM cards may be installed in one Magnum 6K25
Looking into the vertical placed Chassis cover of the unit, there are three brackets with
also used to secure the individual 6KPM cards screen plate which can be subjected to
retaining screws (#256 flat head ) which hold each PM Face plate card slot securely.
There are four PM slots (A, B, C and D) located on the front of the chassis cover.
These six screws shown in the picture below are used to secure a PM face plate in


Managed Fiber Switch unit. Follow these steps to install a 6KPM.
with four stand-off’s for each 6KPM card position. (See Figure 3.5.1b).
significant forces from the attached cables. (See Figure 3.5.1c)


Fig 3.5.2b Granddaughter Board placed in slot
copper 10/100 ports. Port# 1
Can be configured as uplink
(x) crossed ports for
built in stand off (female) provided at the front of the 6K25 Main Board and
Granddaughter board The 5/16 stand off has been used to place the daughter
Fig. 3.5.2c Daughter Board,
A and secured with three 7/16 stand-off’s
screw down tightly with the three 5/16 stand-off (male) on the top of the
top view of version for 4
board on the top of the granddaughter board and latch it securely.
as shown in the Fig.
6KPM card fits into the space provided on the main board.


Fig 3.5.2a Granddaughter Board
cascading · shown separately · Uplink



Fig 3.5.2d Daughter
Fig. 3.5.2e Magnum 6KPM daughter board aligned with the bottom
Board shown upside down with two male latch connectors

female connector for the installation
slowly and firmly with two
properly and the mounting
fingers (as shown below in
Fig. 3.5.2f) on the top of
placed at the bottom of
the daughter board with
connector placed on the
main board. As shown
below in Fig. 3.5.2e
holes are aligned with
stand offs then press
latched up securely.

operational. When leaving 6KPM slots empty, always use a face plate (Magnum 6K8-
BLNK) to cover the slot opening in the front panel. This will maintain proper cooling


complete the installation process for that port module. The front panel screen
Fig. 3.5.2h Inside view of chassis cover (from the rear), showing the front panel
brackets and 6 #256 flat head screws. The brackets and screws have been
slots), the chassis cover should be replaced. Make sure the chassis cover is
panel screen plates need to be placed on the front of the chassis cover to
plate comes along with the package of port module separately along with
air flow, safety, and operation as required by FCC, CE, and other regulations.
installed inside of the top cover as shown in Fig. 3.5.2h.
aligned properly before securing the enclosure.
below shows the top view
holds the daughter board
daughter board with 6
#440 screws, so that it
6KPM cards inside the
securely. The figure
of 6KPM card after
Magnum 6K25.
successfully installing the



COTX require four bracket extender for each(slot A, B, or C COTX). Attach the bracket
from the PCA to the center standoff on the main mother board. The bracket provide
To properly remove a 6KPM card from the 6K25 Managed Fiber Switch,
that has been removed, follow the steps as described for installing a 6KPM card
checking the speed, F/H, and activity status)
the chassis. The screen faceplate screws out from
the inside front of the chassis cover by loosening
On the top of the daughter module there are six
standoffs holding the Granddaughter board with
the 4 screws and bracket while holding it down
position (see Figure 3.5.3a). Remove the three
a 6KPM-BLNK face plate cover.
retaining screws for each 6KPM card. These
screws are used to secure a 6KPM card in
the board near the latch-up connectors as
slot is to remain unused, be sure to install
If another 6KPM card is replacing the one
out the daughter board from the latching
connectors, using both hands, gripping
shown in Fig. 3.5.3b . If the now empty
the stability to the Gigabit module.
3.5.3 Removing 6KPM Cards
follow the 3 steps below.
Carefully and gently pull
discussed in Section 3.5.1.
Card

(the RS-232 port on the 6K25 Switch) to the your PC, so that your PC becomes
Rear View of Magnum 6K25, (Typical Console Port is on the Rear of Reverse 6K25
Software Manual available on GarrettCom‘s FTP site. Detail info. about the MNS is
Use a DB-9 “null modem” cable to connect the Magnum6K25 Console Port
6K25 Switch configuration for Network Management, please refer to Magnum 6K25
3.6.1 RS-232 (DB-9) Console Com port (Serial port) pin assignments.
1 CD Carrier detect (not used)
3 TXD Transmit Data (output)
2 RXD Receive Data (input)
OF
5 GND Signal Ground
4 open not used
6-9 open not used
Pin 5 Pin 1
available on 2.2.9 ( see page no. 13) of this manual.
DB-9 (Console port connector)
the 6K25’s Console Terminal.
CONSOLE
PORT
Models)

intended for temporary connectivity to other equipment such as PCs. Since the
Each time a packet arrives on one of the switched ports, the decision is taken to
either filter or to forward the packet. Packets whose source and destination addresses are
on the same port segment will be filtered, constraining them to that one port and relieving
is on another port segment will be forwarded to the appropriate port, and will not be sent
The Magnum 6K25 Switches operate in the store-and-forward switching mode,
which eliminates bad packets and enables peak performance to be achieved when there is
terminal) to connect directly to the switch using a straight through cable.(Note:
among all of its ports. The Magnum 6K25 supports10/100Mbs for copper media and 10
or 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and
network performance. All ports can communicate to all other ports in a Magnum 6K25,
100Mbps selection for the switched ports must be configured through MNS software per
the rest of the network from having to process them. A packet whose destination address
to the other ports where it is not needed. Traffic needed for maintaining the operation of
The above provided information enables a managed station( a PC or Console
The Null-Modem (DB-9) cable is optional and can be order from the factory,
console port connection is temporary, it is excluded from IEEE 1613 packet-
configuring necessary to be done for basic operation at installation or for maintenance.
(resides inside the unit) on the 6K8-RJ45. Optional Half / Full duplex mode and 10 or
advises that, for substation applications, the serial RJ-45console ports are
This chapter describes the functions and operation of the Magnum 6K25
A Magnum 6K25 provides switched connectivity at Ethernet wire-speed
but local traffic on a port will not consume any of the bandwidth on any other port.
The only hardware configuration settings are user options for an UP-LINK Switch
Magnum 6K25 units are plug-and-play devices. There is no software
unit as per the requirement. The internal functions of both are described below.
the network (such as occasional multi-cast packets) are forwarded to all ports.
loss testing per the 1613 standard-defined test procedure.
heavy traffic on the network.
along with the unit
Switch.
Filtering and Forwarding

PWR : Power LED, ON when external power is applied to the unit.
ACT : ON with port activity for 10 Mbps and 100Mbps operation.
The upper part of the copper port module has a manual Up-link switch, located
An address-aging algorithm causes least-used addresses to fall out in favor of
LK : Steady ON, Link status for 10 Mbps and 100Mbps operation.
position as default factory setting, where used for all-copper module or combo modules.
The Managed 6K25-Series Fast Ethernet copper ports, can be set for either fixed 100Mb
selection is made via MNS software. The factory default setting is for auto-negotiation.
At 10Mb or 100Mb-fixed speed, the user may select half- or full-duplex mode by MNS
All Magnum 6K25 units have address table capacities of 4K node addresses
removed or moved from one segment to another, the 6K25 Switch automatically keeps
100/10 : Speed LED, ON when the speed is 100Mbps , OFF when the speed is 10 Mbps
switching hub in the network. The manual Up-link switch position is configured as (=)
on the inside of the unit on the port module board next to the RJ45 port # 1 which it
The RJ-45 ports independently support auto-cross (MDI or MDIX) in
converter) or fixed mode at 10Mb or 100Mb Half/Full Duplex(managed switch). No
Software for each RJ-45 port separately. For detail information See Section (10.1 at
frequently-used addresses. To reset the address buffer, cycle power down-and-up.
auto-negotiation mode and will work properly with all the other connected devices
with RJ-45 port whether it supports Auto-negotiation or not (e.g 10Mb Hub, media
speed or for 10/100 F/H N-way auto-negotiation per the IEEE802.3u standard. The
page no.52) of this manual to access the “6K-MNS(Rel 3) Software user guide”
suitable for use in larger networks. They are self-learning, so as nodes are added,
controls. It enables the port’s cable to be cascaded (X) to a 10/100Mb repeater or
4.4 Auto-Cross(MDIX) and Auto-negotiation, for RJ-45 ports
cross-over cable is required while using the 6K8’s copper port to other devices.
duplex, OFF for half duplex.
Operation is according to the IEEE 802.3u standard.
For all Magnum 6K25 models :
up with node locations.
Address Learning

copper ports is to connect one of them using a fiber media converter to another Switch in
desirable to operate the fiber link at 100Mb speed, and at either half- or full duplex mode
Attachment to 10/100 auto-negotiation ports typically will not work properly. The 6K25
possible depending on what the other device supports. These are: (1) 100Mb full-duplex,
Switch’s RJ-45 ports handle this situation by configuring the ports as per desire through
connected to another auto-negotiating device, there are 4 different speed and F/H modes
The auto-negotiation logic will attempt to operate in descending order and will normally
mode” result can change at any time depending on network changes that may occur). If
the device at the other end is not an auto-negotiating device, the 6K25’s RJ-45 ports will
try to detect its idle signal to determine 10 or 100 speed, and will default to half-duplex
MNS software port settings and can check the port status of each port after the change.
When Magnum 6K25 RJ-45 copper ports are set for auto-negotiation and are
arrive at the highest order mode that both devices can support at that time. (Since auto-
-- the devices at both ends of the cable are capable of operation at either 10
depending on the capabilities of the remote device. Standard commercially available
Fast Ethernet media converters mostly do not support auto-negotiation properly, and
require that the switched port to which they are connected be at 100Mb fixed speed.
negotiation is potentially an externally controlled process, the original “highest order
Auto-negotiation per-port for 802.3u-compliant switches occurs when:
One frequently-used application for the Managed Magnum 6K25 Switch
-- the second of the two connected devices is powered up*, i.e., when
the network backbone, or to some other remote 100Mb device. In this case, it is
-- the LINK is re-established on a port after being lost temporarily.
(2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex.
Mb or 100Mb speed and/or in full- or half-duplex mode, and can
send/receive auto-negotiation pulses, and . . .
LINK is established for a port, or
at that speed per the IEEE standard.
General information -

may be limited within that collision domain. The Path Delay Value (PDV) bit-times must
attempting to transmit to one 100Mb port, and in other protracted heavy traffic situations.
Magnum 6K25 Switches implement the 802.3x flow control (non-blocking) on
switch prevents frames from entering the device by forcing a collision indication
burst of activity causes the switch to save frames until its buffer memory is full. This is
Full-Duplex ports, which provides for a “PAUSE” packet to be transmitted to the sender
buffer queue increases, the Switch will send a “RESUME" packet to tell the transmitter
802.3x flow control standard in order to communicate properly during normal operation. Note: When in Half-Duplex mode, the 6K25 Switch implements a
When operating in 100Mb half-duplex mode, cable distances and hop-counts
account for all devices and cable lengths within that domain. For Magnum 6K25 Fast
sufficient time to let the Switch reduce the buffer space used. When the available free-
allows the available buffer space to improve as the switch catches up with the
that they are in is powered up. These are exceptions to the “negotiate at
Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.
Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long
most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the
transmitting device is commanded to stop transmitting into the 6K25 Switch port for
to start sending the packets. Of course, the transmitting device must also support the
on the half-duplex ports that are receiving. This temporary “collision” delay
Magnum 6K25 Switches incorporate a flow-control mechanism for Full-
10Mb port is unable to keep up. It can also occur when multiple 100Mb ports are
back-pressure algorithm on 10/100 Mb ports for flow control. That is, the
LINK – enabled” rule above, but may be occasionally encountered.
when the packet buffer is nearly filled and there is danger of lost packets. The
traffic flow.


and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LXSC25)
and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (LXSC70)
Lucent’) web sites and catalogs to provide guidance to network designers and installers.
mode 18+ (0.4) 1300 9/125 -15 -31 14 28 17.5 35
mode 40 (0.4) 1300 9/125 -5 -34 29 58 32.5 65
15.8 12.2 5.5 4.0
mode 2 (0.4) 1300 62.5/125 -19 -31 12 4 16 5.7
Mode 15+ (0.4) 1310 9/125 -15 -28 11 22 - -
1000Mb Multi- mode 0.55 1300 62.5/125 50/125 -9.5 -17 5.5 2 12.5 4
1000Mb Single- mode 10 1300 9/125 -9.5 -20 8.5 17 10.5 21
Receiver Sensitivity and Transmitter Power are the parameters necessary to
The following data has been collected from component manufacturer’s (Agilent’s and
4.6 Power Budget Calculations for Magnum 6K25 PM’s with Fiber Media
compute the power budget. To calculate the power budget of different fiber media
where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
installations using Magnum products, the following equations should be used:
and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
-31 9.0 5.5 3.0 2.0
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
-23.5 -31
OPB (Optical Power Budget) = PT(min) - PR(min)
mode 2 (0.4) 1300 62.5/125
6KPM-SLC 100Mb FX Single-
6KPMMTRJ
6KPMMLC
SXSC
LXSC10
GBIC-
GBIC-
50/125 -20 · 100Mb FX Multi- · 100Mb FX Multi-


This section applies only to PMs shipped as separate items, i.e., 6K25 PMs not
during shipment or delivery. Inspect the contents of this package for any signs
1000Mb Single- mode 25 1550 9/125 -4.0 -21 15 37.5 17.5 43
1000Mb Single- mode 40 1550 9/125 -4.0 -21 15 60 17.5 70
1000Mb Single- mode 70 1550 9/125 -3.0 -23 18 90 20.5 102
* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only
keep the shipping container should you need to ship any of the PMs separately
full-duplex (factory default) setting for 100Mbps fiber ports must be used,
installing a 6K25 PM; notify the carrier of any damage you believe occurred
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
Remove the 6K25 PM(s) from the shipping container. Be sure to
at a later date. In the event there are items missing or damaged, contact your
This chapter describes each Port Module (PM), including appearance,
Examine the shipping container for obvious damage prior to
of damage and ensure that the items listed below are included.
Installation instructions, with illustrations
factory installed in a Magnum 6K25 PM slot.
1 or more 6K25 PMs
if the following factors are both applied:
functionality, and status displays.
This package should contain:
passive Attenuation.
and

Modules for flexible mixed-media connectivity to RJ-45 and fiber media. Since
or 8-port interfaces are designed to support all standard Ethernet media types at
10 or 100Mps speed. Each 6K25 PM provides six or eight ports for connecting
RJ-45 ports or used for COMBO module is set as (=) other user ports.
the Magnum 6K25 Switches have dual-speed capability for copper ports, the 6
10/100Mbps and fiber optic ports at 100MB. The Combo module is equipped with dual-
port supports fiber optic cable distances up the IEEE-standard 100Mbps distance limits,
Link (LK) LED that indicates proper connectivity with the remote device when lit, and
Each 6K25 PM is individually described in the following sections.
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The
supplier. If you need to return the unit, use the original shipping container if
Each port has an Activity (ACT) LED indicating packets being received, a
An important feature of the Magnum 6K25 is the use of Port
For a list of 6K25 Port Module types, refer to Section 1.2
4 Port@ 10/100Mbps and 2 @100 Mb ST Fiber Port
The Magnum 6KP6-RJMST is a combo 6 port module of RJ-45’s at
Ethernet segments with its individual connector type and media.
F/H ACT
4 FULL/HALF
2 6 TX RX TX LK RX LK
possible. Refer to Chapter 5 for specific return procedures.
1 3 5 7
ACT
F/H
LINK 2
i.e., typically 2km at full-duplex and 412m at half-duplex.
ACT
F/H
5.2 6KPM Module Description
100m on each port and the fiber
mode ST-type connectors and
segments. When installed in a
supports the standard distance
dual speed copper ports. The
ST-connector functions as a
fiber optic transceiver to
Switch, the copper port
10/100 · support 100BASE-FX network · Magnum 6K25 Managed

distances up the IEEE-standard 10Mbps distance limits, i.e., typically 2km at full-duplex
hub to connect to the switch through 10Mb fiber ports. It supports distances according to
The 6KP6-RJ10ST is a six port combo module that looks similar to
The ST-connector functions as a fiber optic transceiver to support 10BASE-FX network
segments. When installed in a Magnum 6K25 Managed Switch, the copper port supports
Link (LK) LED that indicates proper connectivity with the remote device when lit, and
the 10Base-FL standard i.e, 2Km distance for multi-mode fiber. (Single-mode for 10Km
received, a Link (LK) LED indicating proper connectivity with the remote device when
the 100Mb combo module with the exception of 10Mb speed at the ST fiber module.
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The
the standard distance 100m on each port and the fiber port supports fiber optic cable
Each port has an Activity (ACT) LED indicating packets being received, a
lit, and FDX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).
10/100 LED indicates the speed, if the LED is ON, 100Mbps if it is OFF, 10Mbps.
Each port has an Activity (ACT) LED indicating packets being
10/100 LED indicates the speed, if the LED is ON 100Mbps if it is OFF 10Mbps.
RX
TX RX LK
4 Port@ 10Mb ST Fiber Port
6KP4-RJ10MST,
2 6 T
ACT
F/H
ACT
F/H
switch. They also provide a convenient way for the half duplex
TX RX LK
TX RX LK
ACT
ACT
F/H
F/H
distance may be available as a special order).
their legacy 10Mb network
Fiber ports. All four fiber
and configured as 10Mb
The 10Mb ST-fiber ports
allow the user to connect
is a 10Mb multi-mode
fiber module with 4 ST-
ports are ST connectors
Half-duplex by default.
to the Magnum 6K25
and half-duplex.
The Magnum 6KP4-F10ST


All four fiber ports are ST connectors and configured as 10Mb Half-duplex by default for
provide a convenient way for the half duplex hub to connect to the switch through 10Mb
10Mb fiber and 100Mb Full duplex for the 100Mb fiber. The 10Mb ST-fiber ports allow
received, a Link (LK) LED indicating proper connectivity with the remote device when
the user to connect their legacy 10Mb network to the Magnum 6K25 switch. They also
distance for multi-mode fiber. (Single-mode for 10Km distance may be available as a
fiber ports. Whereas the 100Mb ST module allow to connect the 100Mb demand of
lit, and FDX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).
Switch devices. It supports distances according to the 10Base-FL standard i.e, 2Km
Each port has an Activity (ACT) LED indicating packets being
5.2.2. 6KP6-RJMSC 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-SC “snap-in” Fiber connector
4 FULL/HALF
10/100 LK
4 Port@ 10Mb ST Fiber Port
1 3 5 7
6KP6-RJMSC,
F/H ACT
F/H
LINK 2
ACTIVITY
ACT
transceivers all in one module. This
is similar to the 6K6-RJMST. It has
module equipped with 4 10/100Mb
RJMSC is also a Combo 6 Port
RJ-45 ports along with 2 multi-
the same LEDs indicating port
activity (ACT), Link (LK), and
lock” Module
FLSTFX is a combo fiber
module with two 10Mb +
combine 4 ST-Fiber ports.
mode 100Mbps fiber optic
5.2.1c 6KP4FLSTFX,
fiber module and in
special order).

While the functionality of these two modules is essentially the same, the 6KP6-
copper at the 100m distance. The Fiber is single-mode and cable lengths can be as much
Link (LK) LED that indicates proper connectivity with the remote device when lit, and a
ports and 2 Single-mode (Long Reach) SC-type connectors. It provides a combination of
5.2.3 6KP6-RJSSC 4@ 10/100Mbps RJ-45 Ports and 2@100Mbps single-mode FX-SC-type, “snap-in” connector
5.2.4 6KP6-RJSSCL 4 @ 10/100 Mb copper port and 2@100Mbps single-mode FX-SC-type, “snap-in” connector
The Magnum 6KP6-RJSSC is also a Combo module equipped with 4 dual speed copper
copper and Fiber functions in one module to the 6K25 Switches, supporting four Copper
supporting the 100m distance and Fiber supporting single-mode fiber cable lengths of as
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The
distinguish the single-mode 6 K6-RJSSC from the multi-mode 6K6-RJMSC, the label
Each port has an Activity (ACT) LED indicating packets being received, a
The 6KP6-RJSSC, when installed in a Magnum 6K25 Switch operates on
The 6KP6-RJSSC, when installed in a Magnum 6K25 Switch has copper
10/100 LED indicates 100Mbps speed when lit and 10Mbps speed when off. To
RJMSC is equipped with an SC-type "snap-in" connector instead of an ST-type.
4 Port@ 10/100Mbps and 2 @100 Mb SSC Fiber Port
10/100 LK
F/H ACT
FDX / HDX and 10/100 operation, and the same face-plate lettering.
supporting four Copper and two single-mode fiber network segments.
1 3 5 7
ACT
and two single-mode (Long-Reach) fiber network segments.
“Sgl. M.” is at the top of the faceplate of the 6K6-RJSSC.
ACTIVITY
much as 40+ Km (see Power Budget, Section 4.5)
F/H
as 25+ Km (see Power Budget, Section 4.5)
equipped with 4 dual speed
mode SC-type connectors. It
module of the 6K25 Switch
copper ports and 2 Single-
and Fiber functions in one
is also a Combo module

The Magnum 6KP6-RJ10ST is also a Combo module equipped with 4 dual speed copper
Magnum 6KP8-MTRJ is a multi-mode fiber optic 8-port module equipped with
10/100 LED indicates the speed for the copper port, which is 100Mbps when the LED is
copper and Fiber functions in one module to the 6K25 Switches, supporting four Copper
Link (LK) LED indicating proper connectivity with the remote device when lit, and a
5.2.4a 6KP6-RJ10ST 4 @ 10/100 Mb copper port and 2@10Mbps multi-mode FL-ST-type, “twist-lock” connector
ports and 2 multi-mode 10 Mb fiber ST-type connectors. It provides a combination of
proper connectivity with the remote device when lit, and a FDX/HDX LED indicating
speed for the copper port, which is 10Mbps when the LED is ON and 10 Mb when the
Each port has an Activity (ACT) LED indicating packets being received, a
FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). The
The 6KP6-RJ10ST, when installed in a Magnum 6K25 Switch has copper
Activity (ACT) LED indicating packets being received, a Link (LK) LED indicating
supporting the 100m distance and Fiber supporting multi-mode fiber cable allow to
connect the legacy network of 10Mb requirement in the network. Each port has an
full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the
“small-form-factor”
ACT
F/H
ACT
F/H
ACT
F/H
ACT
F/H
F/H LK LK LK LK
1 3 5 7
6KP8-MTRJ,
LINK
ACT
F/H
ACT
ACT
ACT
F/H
F/H
and two 10Mb of ST fiber network segments.
ON and 10 Mb when the LED is OFF.
an RJ-45 port, but it is black in
and ease of connection make it
connectivity. When installed in
distances up the IEEE-standard
connector. It looks almost like
color. The MT-RJ’s small size
100Mbps distance limits, i.e.,
a good choice for 100Mbps
a Magnum 6K25 Switch, it
supports fiber optic cable
LED is OFF.
a small-form-factor MTRJ-type · “fiber-to-the-desktop” Ethernet

The functionality of this 100BASE-FX multi-mode 8 Port module is essentially
with two different speeds. The top four ports of MTRJ Small form factor fiber support at
the same as the ST and SC-types. It has the same LEDs per port indicating port activity
The 6KP6-RJ10ST is a combo module with two different kinds of fiber flavor
Fiber connector supports the standard fiber optic distance limit of 2Km at Full and Half-
5.2.5a 6KP6-MT10ST, 4 @100Mb multi-mode FX , MTRJ Small-Form- Factor and 2@ 10Mb Multi-mode ST-Fiber port
100Mb full-duplex, whereas the bottom two ports multi-mode ST-Fiber support 10Mb
half-duplex. This combo module provides more flexibility to the user to connect their
supports fiber optic cable distances up to the IEEE-standard 100Mbps distance limits,
i.e., typically 2km at full-duplex and 412m at half-duplex. The 10Mb Multi-mode ST-
The functionality of this 100BASE-FX multi-mode 4 port module is
4 Port@ 10/100Mbps & 4 port @ 100Mbps
4 FULL/HALF
When installed in a Magnum 6K25 Switch, the 100Mb MTRJ connector
essentially the same as the ST and SC-types. It has the same LEDs per port
indicating port activity (ACT), Link (LK), and FDX or HDX operation
F/H
ACT
F/H
1 3 5 7
LINK 2
legacy 10Mb fiber as well as 100Mb to the Magnum 6K25 Switch.
typically 2km at full-duplex and 412m at half-duplex.
F/H
ACT
F/H
(ACT), Link (LK), and FDX or HDX operation.
copper and fiber (Small Form Factor)
of placing more ports on one module.
10/100 RJ-45 ports and 4 MTRJ fiber
MTRJ connectors give an advantage
The 6KP8-45MT is equipped with 4
MTRJ type ports. The small size of
Module is a combo module with
duplex both.
ports.
10/100 · Multi-Mode Fiber port · The Magnum 6KP8-45MT

at half-duplex.The compact size of the LC Connector reduces the size of wiring panels in
more ports on one module. The
6KP8-45LC is equipped with 4
mentioned on 5.2.3. and the LEDs also
the IEEE-standard 100Mbps distance limits, i.e., typically 2km at full-duplex and 412m
technology.The cable end is a “plug-in” connector with both fiber strands terminated in
indicating packets being received, a Link (LK) LED indicating proper connectivity with
the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit
copper and Fiber (Small Form
10/100 RJ-45 ports and 4 LC(
Small form factor) multi-mode
When installed in a Magnum 6K25 Switch, it supports fiber optic cable distances up to
one housing that cannot be improperly inserted. Each port has an Activity (ACT) LED
The Magnum 6KP8-45LC Module is a combo module with a combination of
small size of LC connectors
give an advantage of having
When installed in a Magnum
6K25 Switch, it supports the
Magnum 6KP8-MLC is a
5.2.8 6KP8-45LC, Combo 4@ 100Mbps multi-mode -LC small-form factor and 4@ 10/100 Mbps RJ-45 Connector
Factor) LC type ports. The
primarily in 100Mbps fiber-to-the-
When installed in a Magnum 6K25 Switch, it supports the standard distances as
eight-port multi-mode fiber LC
wiring closets while providing the advantage of “future-proof” fiber optic
fiber ports.
desktop links.
act similarly.
3 2 4 6 LK LK LK

8Port@ 100Mbps multi-mode LC fiber port
4 Port@ 10/100Mbps & 4 port @ 100Mbps
ACT
F/H
ACT
F/H
LINK 2
(or half-duplex when off).
Multi-Mod LC Fiber port
F/H
F/H
AC
AC
connector “small-form-factor” used · 10/10

Auto-crossover (MDIX), which allow the RJ-45 ports to automatically Link with any RJ-
could produce kigh (greater than 2500V ) levels of ground potential rise (GPR)
during line-to-ground fault conditions. The 6K25 passes the 1613specifications
and will allow both unshielded twisted pair (UTP) and shielded twisted pair (STP) cable
feature eliminates the need for a special twisted pair crossover cable when connecting to
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off), and a
for zero packet loss with fiber ports & with RJ45 ports used as indicated here.
telecommunication multiplexers installed in close proximity (i.e., less than 2
Each port has an Activity (ACT) LED indicating packets being received, a
Link (LK) LED that indicates proper connectivity with the remote device when lit, a
substation applications to interface to field devices across distances which
Crossover (MDI-X) switch, which controls all ports for cascaded connection. This
advises that, for substation applications, the RJ-45 ports are intended for
standard distances as per mentioned on 5.2.8. and the LEDs also acts similarly as
connections. The 6KP8-RJ45 module is equipped with a Media Dependent Auto-
meters or 6.5ft) to the 6K25. It is not recommended to use these ports in
2 4 6 8 F/ H ACT
10/100 LK
connectivity to other communication equipment such as routers or
8 Port@ 10/100Mb Copper ports
1 3 5 7
“10/100” LED indicating 100Mb when lit (or 10 Mbps when off).
6KP8-RJ45,
LINK 2
ACTIVITY
45 device and eliminate the use of cross-over cable.
shielded to minimize emissions
standard length. It is equipped
negotiating capability on each
twisted pair segments of any
connector, and offers 10/100
port. The RJ-45 connector is
with an eight-port RJ-45
a hub or another switch.
full / half-duplex auto-
mentioned above.
10/100 · The 6KP8-RJ45 · module supports Ethernet

devices. The PoE LED is ON when the attached PD is drawing power from the
standard. Only 4 x RJ-
option in one 6K-unit.
available with mix –n-
PoE LED is ON when connected properly to a 803.af compliant PD device on that port.
When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data
LINK and ACTIVITY LEDS are combined on the PoE modules into one LED
through, so the 48VDC power source must be strong enough to provide power
to the 6K switch and to all the 8 RJ-45 ports with PD devices connected (up to
15 watts per PoE port). • In the case where the 48VDC power in not internally connected and no power
5.2.11 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8-
5.2.10 New PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-port
In this Fig. the top 4-
normal MDIX ports.
regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the
match with fiber modules. Please check the ordering information Sec.1.2. for all the
is coming to the PoE ports for some reason, all the PoE port LEDs are ON
The PoE RJ-45 ports act similar to regular RJ-45 ports, except they have
IEEE802.3af PoE
45 (10/100) ports maxm. support
The LEDs on 6KP8-RJ45- PoE module are slightly different compared to
simultaneously to indicate a trouble condition. The ports will still operate
capability of providing power on each port to power up the PD devices, per the
and the PoE LED is OFF. No power is being sent out from the port.
3 F/H POE
2 1 3 5
that is marked as LINK/ACT, as shown in the diagram.
4 FULL/HALF
various PI6K PoE modules option.
properly for data traffic.
8 Port@ 10/100Mb Copper ports
traffic is not affected by PoE.
LINK LK / ACT 2
port.

15watts to power up the PoE PD devices. In this
ports are enhanced with
POE option The 8-RJ45
devices. The PoE LED is ON when the attached PD is drawing power from the
input power supply to
POE module are also available with mix –n-match with fiber modules. Please check the
PoE LED is ON when connected properly to a 803.af compliant PD device on that port.
When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data
LINK and ACTIVITY LEDS are combined on the PoE modules into one LED
through, so the 48VDC power source must be strong enough to provide power
to the 6K switch and to all the 8 RJ-45 ports with PD devices connected (up to
15 watts per PoE port). • In the case where the 48VDC power in not internally connected and no power
standard. The Power
(10/100) ports. Each
regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the
Fig. the top 8-RJ45
is coming to the PoE ports for some reason, all the PoE port LEDs are ON
The PoE RJ-45 ports act similar to regular RJ-45 ports, except they have
IEEE802.3af PoE
The LEDs on 6KP8-RJ45- PoE module are slightly different compared to
simultaneously to indicate a trouble condition. The ports will still operate
capability of providing power on each port to power up the PD devices, per the
and the PoE LED is OFF. No power is being sent out from the port.
ordering information Sec.1.2 for all the various P6K PoE modules option.

that is marked as LINK/ACT, as shown in the diagram.
properly for data traffic.
8 Port@ 10/100Mb Copper ports
traffic is not affected by PoE.
port.


The Magnum GBIC-SXSC is a multi-mode Gigabit fiber connector
supports cable distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e.,

100Mb MTRJ fiber ports. When installed in a Magnum 6K25 Switch, it supports the
equipped with SC type connectors and can be easily snapped in and out. The Gigabit
fiber ports are most popular as server-to-switch and switch-to-switch applications. It
When installed in a Magnum 6K25 Switch, it supports the standard distances as
6 Port@10/10Mbps & 2 port @100Mb Multi-Mode Fiber port
standard distances as mentioned on 5.2.3. and the LEDs also act similarly.
Single-Mode Fiber port (LC)
mentioned on 5.2.4. and the LEDs also act similarly.
fiber (Small Form Factor) LC type
give an advantage of placing more
The small size of LC connectors
10/100 RJ-45 ports and 2 Single-
45-2MT eight port Module is a
combo module with copper and
sizes of MTRJ connectors give
fiber ports on one module. The
6KP8-45-2MT is equipped with
six 10/100 RJ-45 ports and two
combo module with copper and
ports on one module. The 6KP8-
an advantage of placing more
45SLC eight port Module is a
MTRJ type ports. The small
45-2SLC is equipped with 6
fiber (Small Form Factor)
mode fiber ports.
fiber ports.
The Magnum 6KP8- · The Magnum 6KP8-

550m at full duplex.
removing the transceiver, press the clips on either side of the transceiver at the same time
suggestions listed below prior to contacting your supplier. However, if you are unsure of
Each port has an Activity (ACT) LED indicating packets being received and a
supports cable distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e.,
Each port has an Activity (ACT) LED indicating packets being received and a link (LK)
intended to help locate, identify and correct these types of problems. Please follow the
10,25, 40 or 70Km at full duplex, and depend upon the Gigabit modules used.
The 6KM-BLNK is a blank face plate or cover plate that must be installed in
Magnum 6K25 Switch is a straightforward procedure (see INSTALLATION, Section
The GBIC transceiver is fastened using snap-in clips. Insert the transceiver
The Magnum GBIC-LXSC/ZXSC is a single-mode Gigabit fiber connector
equipped with SC type connectors and can be easily snapped in and out. The Gigabit
fiber ports are most popular as server-to-switch and switch-to-switch applications. It
(take care to insert it the right way up, arrows on top) until it clicks in space. While
consistently high performance in all network environments. The installation of a
Should problems develop during installation or operation, this section is
Link (LK) LED indicating proper connectivity with the remote device when lit.
All Magnum Ethernet products are designed to provide reliability and
2.6); the operation is also straightforward and is discussed in Section 4.
LED indicating proper connectivity with the remote device when lit.
underneath the front panel hold
the 6KM-BLNK in place.
and pull the transceiver out.
any empty 6K25 PM slot to
maintain proper cooling air
flow, safety, etc.
Two screws

the procedures described in this section or if the Magnum 6K25 Switch is not performing
as expected, do not attempt to repair the unit; instead contact your supplier for assistance
known good device. Verify whether or not the problem is corrected. If not, go
to Step 5 below. If the problem is corrected, the Magnum 6K25 Switch and its
Switch unit. Be certain that each AC power cord is plugged into a functioning
Switch product, it is recommended that the problem device be replaced with a
of the Magnum 6K25 Switch unit or if unknown, contact GarrettCom, Inc.by
d. Any particular application that, when used, appears to create the problem;
the Installation Section of the applicable chapter of this manual. Also check
electrical outlet. Use the PWR LEDs to verify each unit is receiving power.
to make sure that the various components of the network are interoperable.
number(s). Include the date(s) that you purchased the products from your
impaired during installation. (About 90% of network downtime can be
connected and the cables/wires have not been crimped or in some way
fax, phone or email (support@garrettcom.com) for assistance.
Please be prepared to provide the following information.
attributed to wiring and connector problems.)
c. The components involved in the problem;
associated cables are functioning properly.
a. The nature and duration of the problem;
b. Situations when the problem occurs;
6.2 When Calling for Assistance
or contact GarrettCom Customer Support.
supplier.

sheet or bag for shipping protection. ( You may retain all connectors and this
All returns for repair must be accompanied by a Return Material Authorization
material. This material may cause electro-static shock damage to the unit.
including personal computers, workstations, terminals and printers; plus, the
https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.
GarrettCom will carefully test and evaluate all returned products, will repair products
to the occurrence of the problem. Any changes to system administration
that are under warranty at no charge, and will return the warranty-repaired units to
the sender with shipping charges prepaid (see Warranty Information, Appendix A,
units under warranty. Testing and repair of product that is not under warranty will
Should you need to ship the unit back to GarrettCom, please follow these
GarrettCom reserves the right to charge for the testing of non-defective
for complete details). However, if the problem or condition causing the return
Failure symptoms, including a full description of the problem.
6.3 Return Material Authorization (RMA) Procedure
(RMA) number. To obtain an RMA number, please use this URL -
cannot be duplicated by GarrettCom, the unit will be returned as:
Name and phone number of your contact person.
Please have the following information readily available:
Packing List Number (or Sales Order Number)
procedures should all be noted in this record.
various network media types being used.
No Problem Found.
Name of your company / institution
Serial Number (or Invoice Number)
result in a customer (user) charge.
Installation Guide.)
instructions:
Your shipping address · Date of installation · Product name

GarrettCom, Inc. warrants its products to be free from defects in materials
replace components in the products that prove to be defective at no charge other
product has been damaged by misuse, misapplication, or as a result of service or
This warranty will not be effective if, in the opinion of GarrettCom, the
Please complete the warranty card as this acts as a product registration,
and workmanship for a period of three (3) years from the date of shipment by
than shipping and handling, provided that the product is returned pre-paid to
inspecting any product returned for warranty repair which turns out not to be
During this warranty period, GarrettCom will repair or, at its option,
GarrettCom reserves the right to make a charge for handling and
Power Supply (Internal 125 VDC Option) Industrial Applications
Power Supply (Internal 24 VDC Option) Industrial Applications
DC Power Connector: 3 terminals: “ - “, “GND”, “+”
and mail it to GarrettCom within two weeks of your purchase.
APPENDIX A: WARRANTY INFORMATION
47823 Westinghouse Dr.
modification other than by GarrettCom.
Power Supply (Internal -48VDC Option)
GarrettCom, Inc.
GarrettCom.
GarrettCom.
faulty.
Fremont, CA 94539-7437

connection, for example, will neither affect the Switch, its internal power supply, nor will
The manual power “On-Off” Switch (optional) is used for powering the unit on
The –48VDC solution is particularly useful in the telecommunication industry,
other communication companies. In addition, many high availability equipment services,
facilities often use a battery backup system to maintain operations in the event of a power
environment, where it is common facilities to operate on 24VDC or 125VDC power. The
The -48VDC, 24VDC and 125VDC power options are designed using diodes
inside on each DC power input line behind the two external power connection terminals,
Magnum 6K25 Fiber Switches are easily installed in a variety of applications
where -48VDC, 24VDC and 125VDC power is used as the primary power source. The-
where it is common for facilities to operate on -48VDC power. Such companies include
regular and wireless telephone service providers, Internet Service Providers (ISPs) and
B2.0 -48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION
48VDC, 24VDC and 125VDC power configuration provides an Ethernet networking solution utilizing a special power supply in a managed Fiber Switch.
The 24VDC and 125VDC solution are particularly useful in the Industrial
125VDC solution is mainly used in power utilities, such as electrical substations, electrical generating plants, etc. The 24VDC applications are mainly in the Industrial
functions of Magnum 6K25 Switch -48VDC, 24VDC and 125VDC models are
It protects the Switch from incorrect DC input connections. An incorrect polarity
such as broadcasters, publishers, newspaper operations, brokerage firms and other
With the exception of the power supply, all specifications and
failure. It is also frequently used for computer system backup, management and
environment, such as factory floor, HVAC equipment, military equipment, etc.
SUPPLY
B3.0 APPLICATIONS FOR DC POWERED SWITCHES
and off when it is placed into or taken out of service.
identical to those listed in the main manual.
it blow the fuse in the internal power supply.
A-
correctly applied to the two inputs.
so that the power from an external
source can only flow into the hub.
operations monitoring equipment.
This allows the Switch to operate
only whenever DC power is

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage
The actual connection procedure is very straightforward. Simply connect the
An ON-OFF manual switch is optional for DC power. This can be used to cut
This section describes the installation of the -48 VDC, 24VDC and 125VDC
power source leads to the -48 VDC, 24VDC and 125VDC power terminal block on the
Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or
leads to the Magnum unit, beginning with ground. Ensure that each lead is securely
36-70VDC
user may elect to Ground either + or = terminal to suit the customer’s use.
lead from 48V or –48V supply must be connected to the post labeled “+”.
off power connections and as a RESET for the Magnum 6K25 Switch.
ON
The leads are identified as negative (-),
B4.1 UL Requirements for DC-powered units
within 6 inches of the terminal block.
terminal block on the Magnum 6K25 is
Magnum 6K25s. (see figure at right).
In this picture, the -48VDC
lead posts. It is similar for 24VDC and
located on the rear of the unit and is
equipped with three (3) screw-down
125VDC options on Magnum 6K25.
and chassis ground (GND).
tightened.

Operation of Magnum 6K25 Switches with the optional -48VDC, 24VDC and
To order the optional -48VDC power supply factory installed, add a suffix of “-
24VDC and 125VDC models with this Dual-Source option are identical to those listed in the Magnum 6K25 Fiber Switches Installation and User Guide, including Appendix B
C2.0 MAGNUM 6K25, with -48VDC, 24VDC and 125VDC Dual-Source option
Similarly to order the optional 24VDC or 125VDC industrial specific power
-48VDC” after the product’s standard model # Example: Magnum 6K25R-48VDC.
supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s
With the exception of the dual DC input power connections and the power
supply, all specifications and configuration options for the Magnum 6K25 -48VDC,
The 6K25-Switch models with the internal -48VDC, 24VDC and 125VDC
Dual-Source power supply are designed for installations where a battery plant is the
power source, and where two separate power sources are utilized in order to increase
standard model #. Example: Magnum 6K25- 24VDC, Magnum 6K25-125VDC.
Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-24V)
125VDC power supply is identical to that of the standard AC-powered models.
Power Supply (Internal, -48VDC Dual-Source, model # Dual-Src-48V)
Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)
Please refer to Section 6.0 for troubleshooting
operational uptime and to simplify maintenance.
B7.0 TROUBLESHOOTING
“Internal DC Power Supply Option”

The functionality of the Magnum 6K25 Switch -48VDC, 24VDC and 125VDC
d) Reverse polarity connections, if they should accidentally occur on either input, will not damage
positive(B+). The chassis “earth” or ground (GND) is a threaded post with a #6 nut. The
Terminal Block on a Magnum 48VDC with Dual-Source option
Dual-Source Option units is identical to the standard AC-powered models. Refer to the

a) The Switch unit can receive power from either input, “A” or “B”. The hub will normally draw
125VDC dual source leads to the -48VDC, 24VDC 7 125VDC power terminal block on the Magnum 6Ks Switch (shown in Figure )
b) The Switch unit will not allow power to flow from a higher voltage input to a lower voltage
c) When one correct DC input is present, the Switch will receive power if the other DC input is
the Switch or power supply internally (nor will it blow the fuse in the internal power supply)
e) The Switch will not receive power (and will not work) when both inputs are simultaneously
can only flow into the unit. This allows the unit to operate whenever DC power is
because of the blocking action of the diodes. This is true even if one input connection is
This section describes the proper connection of the -48VDC, 24VDC and
The -48VDC terminal block on the Magnum 6K25 Switch, as shown in Fig C5.0 is
main sections of this Installation and User Guide for a detailed description of the
36-70VDC GND
absent, or even if it is connected with reverse polarity or shorted or grounded.
A+ AB- B+
Dual Source terminal block for the 24VDC and 125VDC are similar.
its power from the DC source with the highest voltage at a given time.
input, i.e. the two DC power sources are not mixed together by the hub.
reversed while the Switch is operating from the other source.
correctly applied to either or both of the two inputs
A-
B-
absent or are both incorrectly connected.
located on the right rear of the unit and
is located on the left rear. The primary
(A+), negative (A-), and the secondary
The Dual-Source DC power
option is designed using diodes inside
of the chassis on each DC power input
external power connection terminals)
so that power from an external source
is equipped with five (5) screw-down
lead posts. If it is the reverse model it
line. A diode is placed in each of the
terminals are identified as positive
power terminals as negative (B-),
four input lines (behind the four
Magnum 6K25 Switches.

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage
Dual-Src-48V for the regular DS model with no ON-OFF switch
The connection procedure is straightforward. Simply connect the DC leads to
The 24VDC & 125VDC terminal block on Magnum 6K25’s is similar to that
Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or
the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground
(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely
Similarly, order the “Dual –source 24VDC” or “Dual-source 125VDC” as a
Or Dual-Src125V-Switch for models with the ON-OFF switch
Operation of the Dual-Source Magnum 6Ks-48VDC, 24VDC and 125VDC
The following must be adhered to in order to conform to UL requirements:
To order the optional Dual-Source -48VDC power supply factory installed,
order “Dual-Src48V” as a separate line item following the product model.
or Dual-Src48V-SWITCH with the ON-OFF manual switch.
Dual-Src24V for regular models with no ON-OFF switch
user may elect to Ground either + or = terminal to suit the customer’s use.
lead from 48V or –48V supply must be connected to the post labeled “+”.
Switch models are identical to that of the standard models.
separate line item following the product model.
within 6 inches of the terminal block.
described in the –48VDC information above.
C7.0 OPERATION
C5.1 UL Requirements
tightened.