SUPERVISED WIRELESS SECURITY CONSOLE


CONGRATULATIONS for selecting Linear’s DVS-2400 Security System. The DVS-2400 Console incorporates many advanced and sophisticated features. The system can be expanded and customized to fit the installation’s specific needs.

The DVS-2400 Console and its accessories are designed and manufactured by the oldest wireless security company in North America. You can look ahead to many years of reliable service with this Console and its accessories.
Many insurance companies offer discounts on homeowners and renters policies when a security system is installed. Discount credits vary with different companies and generally increase in savings with an increase in the level of protection. Inform the user to ask their insurance agent about savings available.
In this manual, the bullets preceding the text help to define the step. For example:
◆This symbol indicates a feature.
This symbol indicates an action to perform and provides a box to check when the action is completed. ❇This symbol is for lit indications or system
sounds. ✍This symbol is for important notes.




DXS-31 DOOR/WINDOW
DXS-81 BILL TRAP
DXS-54
DXS-91 GLASS BREAK DETECTOR
DXS-72 SMOKE DETECTOR
SENSOR
SENSOR
PIR
CONSOLE The DVS-2400 Console is the heart of the system. It monitors all of the system’s wireless sensors and controls the alarm sirens.
capability at the Central Station through the communicator, local human voice prompts from the Console’s speaker, and voice prompted remote system control using in-house or off-site pushbutton telephones. The economy Model VB-3 is the same as the VB-2 without 2-way Central Station audio capability.
The Console constantly monitors the condition of the system’s sensors, displaying which protected doors and windows are open or closed. If an alarm occurs, the Console displays which sensor(s) caused it. When a sensor has a low battery, the Console displays which sensor needs a new battery. Sensors that send hourly status transmissions keep the Console informed of their operating condition.
The Console has 24-hour capabilities that are always ready to operate, even when the Console is disarmed. They can be triggered by buttons on the Console, the Wireless Keypad, portable remote controls and smoke detectors. Pressing the [EMERGENCY] or [FIRE] button for two seconds will cause an immediate siren and call the central station. IMPORTANT: For personal emergency use only.
Up to eight different custom user codes can be used to operate the system. For security, a user code must be entered to disarm (turn off) the system. The system can be armed (turned on) by entering a user code, or with the unique “Quick Arm” feature. The five restricted user codes and the special page alert user code can only arm and disarm the system, no programming changes are allowed. The master user code is allowed to program the Console, and a duress code can be selected for emergency disarming of the system with a duress report to the Central Station. The page alert user code can dial a pager number to inform the pager wearer when the Console is disarmed.
The Console’s Environmental feature is active 24-hours and can be triggered with sensors connected to devices such as water flow detectors, over/under temperature sensors, flood sensors, toxic gas detectors, etc. The Environmental feature activates the chime annunciator without sounding the siren. The Environmental feature does not send communicator reports.
An Automation Output in the Console provides an easy way to connect external devices to the Console. The output is fully programmable to activate on a variety of conditions, such as when the system is armed, during alarms, and during exit/entry delays. The Automation Output can connect to lighting control modules, relays, noisemakers, and indicators. The Console’s and wireless keypad’s (A) key and transmitters can control the Automation Output.
The Console’s memory will retain the user codes and all of the system’s programming, even during a total power loss. An optional backup battery can be installed to power the system during short power failures.
The built-in digital communicator connects the Console to a Central Alarm Monitoring Station through the telephone. With a monitored system, the central station can dispatch authorities in case of burglary, fire or other emergency. The central station can also call family, friends, neighbors, or anyone else designated on a custom call list.
The Console can be programmed locally using its own keypad or remotely, over the telephone, using Linear’s Model RA-2400 Remote Access software program. The RA-2400 upload/download program is a Windows application that runs on a personal computer and communicates with the Console through a modem, connected directly to the Console or through the telephone line.
Each sensor can report directly to the Central Station using the digital communicator’s Point ID feature. If a sensor triggers an alarm or experiences supervisory trouble, a unique report code can be sent for immediate identification of the event.
The optional Models VB-2 or VB-3 digital voice synthesis modules can be installed in the Console. The VB-2 module provides three exciting features: 2-way audio monitoring

DOOR/WINDOW SENSORS The DXS-31 & DXS-32 sensors monitor doors and windows. They send radio signals to the Console. One type of signal is sent when the door or window is opened, and a different type of signal is sent when the door or window is closed. If the Console is armed, a sensor can trigger the Console’s burglary siren when its door or window is opened. Both sensors are supervised, and send hourly status reports and monitor battery condition.
PANIC BUTTONS The DXT-21, DXS-21 single-button and DXT-23 and DXS-23 two-button transmitters can be used as portable “panic buttons”. Pressing the front or top button on the DXT-21, DXS-21 at any time will trigger the emergency siren. Pressing both front buttons simultaneously on the DXT-23 & DXS-23 at any time will trigger the emergency siren. These transmitters can be programmed to activate various other Console functions. The DXT-21 and DXT-23 transmitters are not supervised. The DXS-21 and DXS-23 transmitters are supervised.
DXS-31
WIRELESS KEYPAD The DXS-10 wireless keypad is used to control the Console remotely. It can be placed in a convenient spot so the user doesn’t have to go to the Console to control the system. The wireless keypad can also trigger the emergency or fire siren and actuate the Automation Output. Pressing the [∗] key will cause the Console to sound beeps corresponding to the current operating mode. The DXS-10 is supervised, it sends hourly status reports and monitors its battery condition.
DXT-23 DXS-23
The DXS-62 and DXS-63 transmitters can be used as portable “panic buttons”. Pressing the single button on the DXS-62, or pressing both buttons on the DXS-63, at any time will trigger the emergency siren. These supervised transmitters send hourly status signals and low battery signals if the battery is low.

SMOKE DETECTORS The DXS-72 is a high quality smoke detector with a built-in radio transmitter. As soon as smoke is detected, the unit will sound its local noisemaker. Then, 20 seconds after the local noisemaker sounds, the transmitter sends an alarm signal to the Console. The alarm signal will be repeated every 20 seconds as long as smoke is still present. A restoral signal will be sent when the smoke detection chamber clears. The DXS-72 is supervised, and sends hourly status reports and monitors battery condition.
BILL TRAP The DXS-81 bill trap can be used with the Console in small commercial hold-up installations. The unit is concealed in a cash drawer under a stack of currency, with a single “bait” bill secured in its money clip. During a hold-up, the cashier removes the stack of currency along with the “bait” bill. When a “bait” bill is removed, the transmitter sends a signal to the Console. Four additional signals are sent within the first minute after the “bait” bill is removed. When the “bait” bill is replaced, a restore signal is sent. The DXS-81 is supervised, it can send hourly status reports (optional) and monitors its battery condition.

REMOTE CONTROLS The DXT-41, DXT-61 single-button and DXT-23, DXT-42 multi-button remote controls can be used to remotely arm and disarm the Console. The DXT-42’s left button will arm and the right button will disarm the Console. Pressing both buttons simultaneously on the DXT-42 will trigger the emergency siren. Alternately, the console can be programmed to respond to the DXT-42 by arming and disarming with the left button, and activating the automation output with the right button. Each transmitter can be programmed to activate various other Console functions. These transmitters are not supervised.
PASSIVE INFRARED MOTION DETECTOR The DXS-54 is a passive infrared (PIR) motion detector with a built-in radio transmitter. The PIR detects motion in its detection pattern by measuring the infrared emission levels of objects that it “sees”. If the infrared levels change quickly, as when a person moves across the detection pattern, the PIR will recognize the change as an intrusion and send an alarm signal to the Console. An alarm will be triggered if the Console is in the Away Mode. The DXS-54 is supervised, it sends hourly status reports and monitors its battery condition.
DXT-42
DXT-61
GLASS BREAK DETECTOR The DXS-91 is a glass break detector with an audio sound discriminator and a built-in radio transmitter. The unit “listens” for the sound of breaking glass. When glass breakage is detected, the unit sends an alarm signal to the Console. The DXS-91 is supervised, it sends hourly status reports and monitors its battery condition.
DXS-91

◆The example shows a typical DVS-2400 system. ◆Any or all of the accessories shown can be used. ◆A total of 24 sensors (including keypads) can be
used with each Console.
Create a floor plan of the installation. Consider the security needs of the premises. Determine which doors and windows are vulnerable to intrusion. Figure which interior areas an intruder might go to if unlawful entrance is gained. Indicate locations for door/window sensors, interior motion detectors, keypads, glass break detectors and external siren speakers. Decide on a centralized location for the security Console.
MD MS S
GB
S
CON - CONSOLE S - DOOR/WINDOW SENSOR WK - WIRELESS KEYPAD MD - MOTION DETECTOR ES - EXTERNAL SIREN SD - SMOKE DETECTOR GB - GLASS BREAK SENSOR MS - EXTERNAL MAGNETIC SWITCH
LIVING
ENTRY
S
S
KITCHEN
CON
S
BED
DINING
S
MS
S MS
SD
BED
BATH DEN
S
S
GB
GARAGE
Example Residential Security System Floor Plan


magnet. ◆ Opening door or window moves magnet away,
triggering sensor. ◆ Internal lithium batteries are monitored by the
Console. ◆Sends hourly status reports to the Console. ◆Up to 3 years battery life (depends on frequency
to the Console. ◆ Emergency and fire alarm can be triggered from
wireless keypad at any time. ◆Green operation light. ◆Internal 9-volt battery is monitored by the

when the battery is low. ◆Up to 3 years battery life (depends on frequency
of activation). ◆Sends hourly status reports to the Console. ◆Press the [(A)] key to activate the automation
output. ◆Pressing [∗] clears the keypad. ◆Holding [∗] for two seconds sounds the mode
beeps from the Console.
✔Off Mode: 1 “Gong” ✔Chime Mode: 1 “Gong” & 1 “Beep”. ✔Home Mode: 1 “Gong” & 2 “Beeps”. ✔Away Mode: 1 “Gong” & 3 “Beeps”. ✔Test Mode: 1 “Bing” & 4 “Beeps”.
All DXS Format sensors transmit hourly status reports. All DXT Format sensors do not transmit hourly status reports. Both sensor formats can be used with the Console. When a sensor is programmed into the Console, the Console will set the sensor as non-supervised or supervised. Sensors set as non-supervised are not expected to send hourly status reports. Sensors set as supervised are expected to send hourly status reports. If a status report is not received in 8 hours from a sensor set as supervised, the TROUBLE indicator will flash. When sensors are programmed into the Console, ALL STATIONARY SENSORS ARE SET AS SUPERVISED, ALL PORTABLE SENSORS ARE SET AS NON-SUPERVISED.
If stationary DXT Format sensors have been programmed into the Console, be sure to change their setting to non-supervised to prevent TROUBLE indications. This will not prevent low battery monitoring.
If portable DXS Format sensors have been programmed into the Console, and the installation requires supervision for specific portable sensor(s), change the selected portable sensors setting to supervised.
After programming the sensors, if changes are required, refer to “Changing a Sensors Supervision” on Page 26 for details on changing the way a sensor’s supervision is set.


★Specific indicator will light showing the mode the Console is in. ★HOME indicator will blink during secure exit and home instant modes. ★AWAY indicator will blink during the exit delay in the Away Mode.
★Show the current status of the Console.
★Glows when AC power is on. ★Dims when AC power is off and backup battery is installed. ★Blinks when the backup battery is low, recharging or missing. ★Off when AC power is off and no backup battery is installed (system
disabled).
★Blinks when one or more sensors has a low battery. ★Press [∗] key for two seconds to view sensor status. Sensor status indicator
for any sensor with a low battery will light along with the BATTERIES indicator. ★Switch to Test Mode after replacing the sensor battery and completely test
the system (see Test Mode). Switching to Test Mode clears the low battery indication.
★Blinks when one or more sensors have not reported status during the eight
1 24-HOUR BUTTONS ★Pressing the [FIRE] button for two seconds sounds the fire siren and sends
hour status time window. ★Press [∗] key for two seconds to view sensor status. Sensor status indicator
a “fire” message to a central monitoring station through the digital communicator (if the system is monitored). ★Pressing the [EMERGENCY] button for two seconds sounds the
for any sensor that has not reported in will light along with the TROUBLE indicator. ★Switch to Test Mode after servicing the sensor and completely test the
emergency siren and sends an “emergency” message to a central monitoring station through the digital communicator (if the system is monitored). ★Both work even when system is disarmed. ★IMPORTANT: For personal emergency use only.
system (see Test Mode). Switching to Test Mode clears the trouble indication.
★Makes unique sounds for burglary, fire and emergencies. ★Alarm sirens stop automatically after five minutes. ★Sounds advisory tones to confirm keystrokes from the Console. ★Sounds mode selections tones. ★Sounds alarm memory tones. ★Beeps when Automation Output is activated. ★Speaks the system status information when optional VB-2 or VB-3 digital
★Used to control the Console.
★Off Mode disarms the system. ★Switching to Off Mode stops the alarm siren.
✔Multiple beeps sound and status lights flash if an alarm has occurred. ☞Multiple beeps mean caution. AN INTRUDER MAY STILL BE PRESENT.
voice synthesis module is installed. ★Terminals available for an external siren.
CHIME
★Indicates the status of each of the system’s sensors. ★Lights show which doors and windows are open. ★Lights flash to display sensors that have caused an alarm. ★Stick-on labels are provided to identify the custom sensor locations.
★Chime Mode disarms the system. ★Switching to Chime Mode stops the alarm siren.
✔Multiple beeps sound and status lights flash if an alarm has occurred. ☞Multiple beeps mean caution. AN INTRUDER MAY STILL BE PRESENT. ★Chime Mode is for monitoring doors and windows.
✔Use this mode as an “automatic door chime” when at home. ✔Opening any protected door or window causes Console to “ding-dong”.
★Remove clear display window and sensor identification card to gain access
to the screw. ★Remove case access screw to unlock case. Case hinges open to the left.
★Home Mode arms the perimeter sensors, but not the interior sensors.
✔Use this mode when anyone is staying behind. ✔Interior motion detectors and interior door sensors are not armed. ✔Home secure mode makes all delayed perimeter sensors instant. ✔Secure exit mode starts an exit delay while remaining in Home Mode. ✔Re-entering during the exit delay restarts the exit delay (one time only).
★Backlit keys for easy viewing in low light conditions. ★For entering the user’s user code (numerically or alphabetically). ★Used when programming system options. ★Press [(A)] key to activate Automation Output. ★Press the [∗] key to clear keypad if the wrong key is pressed. ★Press and hold the [∗] key for one second to view sensor battery and
supervisory status (see BATTERIES and TROUBLE indicator description).
★Away Mode arms the entire system.
✔Use this mode when leaving home. ✔Door sensors set for “delayed” will have a delay that allows you to leave
and enter the premises without sounding the alarm. ✔Re-entering during the exit delay restarts the exit delay (one time only). ✔Entry Delay beeps warn you to disarm the system before the siren starts.
★Test Mode is for testing the system sensors.
✔All sensor status lights blink when the Test Mode is entered. ✔Each sensor status light will stop blinking when its sensor is tested. ★Hold the [TEST] button down to test all of the Console’s indicator lights.


17 WIRING ACCESS HOLE
★Type 2AG, 1-amp fuse. ★Protects the external relay output when used with wet contacts (12 VDC
★Provides access to recessed wiring trough in base of Console. ★Route cables for power, telephone, external speaker, etc. through this hole. ★Loop for zip-tie strain relief provided next to hole.
switched out). ★Fuse will blow when load exceeds 1 amp. ✍WARNING: For continued protection against the risk of fire, replace
★Used when mounting Console recessed in the wall. ★Two mounting brackets (supplied) slide through slots and are retained by
only with the same type and rating of fuse.
screws, clamping the unit to the wall.
★Terminals for connection to the plug-in AC transformer. ★Terminals for connection to an external speaker. ★Automation Output to connect to an automation controller. ★External relay output for “wet” contacts (switched 12 volts) or “dry” contacts
★Used to monitor the Console’s radio receiver during troubleshooting. ★Provides connection for an audio amplifier to listen to the receiver’s output. ★Helpful to determine sources of radio interference.
(normally open 1 amp @ 24 volts maximum).
12 BATTERY FUSE
★High sensitivity microphone. ★Detects room audio when communicator is reporting to the Central Station
★Type 2AG, 3-amp fuse for the backup battery. ★If the POWER light is flashing and the optional backup battery is installed
in 2-way audio mode (Model VB-2 digital voice synthesis module must be installed).
and charged, check this fuse. ✍WARNING: For continued protection against the risk of fire, replace
only with the same type and rating of fuse.
★Varies the volume of the advisory tones that come from the speaker. ★Does not affect internal or external sirens (they are always full volume).
★Provides telephone connections for the digital communicator. ★Provides telephone connection for voice prompted telephone remote control
★Two voice synthesis modules are available, the Model VB-2 and VB-3. ★Both modules allow remote command of the Console using a standard
(optional VB-2 digital voice synthesis module required). ★Provides seized ring and tip connections for local telephone instruments.
pushbutton telephone, on or off site. ★Both modules provide optional human voice prompts from the Console’s
Communicator will disconnect local telephones while on-line.
speaker. ★The Model VB-2 gives the Console’s digital communicator listen-only,
★Connects the internal speaker to the Console circuit board. ★2-pin connector, non-polarized.
manual 2-way and full duplex 2-way audio capability with the Central Station.
★Antenna and ground terminals for receiving signals from the system’s
sensors. ★Pre-wired to the Console’s internal wire dipole antenna. ★Alternately connects to the Model LA-P local whip and remote antenna kit.
★Space for 12-volt, 1.2 amp/hour backup battery. (Highly recommended.) ★Backup battery is automatically charged and monitored by the Console. ★Backup battery can power the Console for up to 6 hours.

✍ NOTE: Sensor signals must be able to reach the

Console.
✔Try to centrally locate the Console. ✔Keep Console away from large metal
appliances. ✔Maximum recommended sensor range is
USE A PAPER CLIP TO REMOVE THE CLEAR DISPLAY WINDOW
400 feet (system tested at 1000 feet). ✍NOTE: If you don’t use the Wireless Keypad, the
Console should be easily accessible to the usual entrance.
✔When the Console is set in the Away Mode,
the user has 30 seconds to switch to Off Mode before the burglary siren sounds. ✍NOTE: Make sure the Console is in a place where

the alarm can be heard during the night hours.
✔Optional remote external sirens (up to 150
feet from the Console) can be used to make alarms louder and remote their location. Locate the Console near an AC power outlet that’s not controlled by a light switch. Locate the Console near a telephone outlet (if using the digital communicator).
◆ To access the Console’s internal components or

to prepare the Console for wall mounting, the case locking screw needs removing. Use a paper clip to remove the clear plastic display window. Remove the sensor number nameplate. Remove the case locking screw.
CUT A 10" x 6 3/4" HOLE CENTERED BETWEEN STUDS IN MOUNTING WALL AT A CONVENIENT HEIGHT
◆ If desired, the Console can be surface mounted
or recessed into the wall. Surface Mounting
For surface mounting, use the Console’s case bottom as a template and mark the locations for the four mounting screws. Use four screws and appropriate screw anchors to temporarily mount the unit to the wall (the unit will need to be removed to complete the recessed wiring hook up). Recessed Mounting

For recessed wall mounting, cut a 10" by 6-3/4" hole, centered between studs, in the mounting wall at a convenient height. Slide the unit into the mounting hole and temporarily secure it with the two retaining clamps and screws provided (the unit will need to be removed to complete the recessed wiring hook up).

SECURE CONSOLE TO WALL USING THE TWO CLAMPS AND SCREWS PROVIDED


◆ An external console speaker sounds system
tones and alerts occupants with a loud siren during alarm. ◆With the VB-2 module installed, the Central
Station can talk to the occupants through the external console speaker. ◆Use an 8-ohm, 10 watt minimum rated speaker.
Do not use a horn/siren with a built-in siren driver. ◆Up to two 8-ohm speakers can be used with
AC AC EXT. SPKR (-) H/A - H/A + RELAY N.O. RELAY DRY
each Console. ◆Up to 150 feet of 22 AWG wire can be used with
JUMPER FOR EXT. SPEAKERS OPTIONAL VOICE MODULE MODEL: VB-2 OR VB-3
each speaker. Mount the external speaker. Route the speaker wires from the external speaker to the Console. Open the Console top cover and locate the main terminal block. Route the speaker wires up through the wiring access hole. Remove the wire jumper from the EXT. SPKR & (-) terminals. Connect the speaker wires to the EXT. SPKR & (-) terminals. ✍NOTE: If connecting two external speakers,
connect the second speaker in parallel, to the same EXT. SPKR & (-) terminals as the first speaker. The system tone volume can be adjusted with the annunciator volume control.
CONNECT SPEAKER LEADS TO EXT. SPKR & (-) TERMINALS

◆ An external siren alerts occupants and neighbors
with a loud siren during alarm. ◆Use a 12 volt, 1 amp maximum rated
weather-resistant horn speaker with a built-in siren driver. Do not use a plain speaker. ✍NOTE: Connection of an electromechanical bell or
motor bell is not recommended because of the radio interference generated when the bell is running. Mount the external siren. Route the wires from the external siren to the Console. Open the Console top cover and locate the main terminal strip. Route the siren wires up through the wiring access hole. Connect the siren wires to the RELAY N.O. & (-) terminals. ✍NOTE: By removing the Console’s auxiliary fuse,
AC AC EXT. SPKR (-) H/A - H/A + RELAY N.O. RELAY DRY
the relay contacts will become isolated. Use the RELAY N.O. & RELAY DRY terminals to switch an externally powered load.
CONNECT SIREN LEADS TO (-) & RELAY N.O. TERMINALS


TERMINAL
system is monitored, requires 2-way audio, or requires telephone remote command. ◆Telephone ring & tip terminals are for connection
to the incoming telephone line. ◆Seized telephone ring & tip are for connection to
local telephone sets. When the communicator activates, all the local telephone sets will be disconnected to prevent an off-hook telephone on the premises from blocking the communicator call. Install a USOC RJ31-X or RJ38-X jack to the telephone system near the Console. Route an appropriate modular telephone line cord from the jack to the Console. Route the line cord through the Console’s wiring access hole. Connect the incoming telephone line wires to the Console’s telephone terminal block TIP and RING terminals. ◆Connect the local telephone set wires to the
LINE RING (R) LINE TIP (T)

T R R1 T1 SHORTING BAR SHORT REMOVED ON PLUG INSERTION
Console’s telephone terminal block SEIZED TIP and SEIZED RING terminals. ◆When directly connecting (without a telephone
line) to the DVS-2400 with the RA-2400 remote access software (Version 1.3 or later), disconnect the incoming telephone line and connect the modem to the panel’s TIP and RING terminals (with the modem’s red & green phone line wires). Press the [EMERGENCY] key while in Test Mode to cause the panel to connect to the modem.
AUTOMATION OUTPUT CONNECTION (OPTIONAL)
◆ The Console provides a Automation Output to
control lights, devices and appliances. ◆Automation Output can connect to most popular

MINUS H/A TERMINAL WILL SWITCH TO GROUND WHEN AUTOMATION OUTPUT IS ACTIVATED
home automation devices and other simple electronic devices (see Figure). Press [(A)] to turn the Automation Output on, press [(A)] again to turn it off. Programmable Options
AC AC EXT. SPKR (-) H/A - H/A + RELAY N.O. RELAY DRY
BLOCK
◆ There are many programmable options for the
Automation Output. ◆ The Automation Output can be programmed for
POSITIVE H/A TERMINAL PROVIDES +12 VOLTS DC AND IS CURRENT LIMITED AT 30 MILLIAMPS MAXIMUM
a variety of useful functions, such as: flashing during alarm, flashing after an alarm, on while armed, or, on during exit/entry delays. ◆See the “Advanced Programming” section of this
X-10 BURGLAR ALARM INTERFACE (CAN CONTROL HOUSE LIGHTS THROUGH X-10 SYSTEM)
LIGHT EMITTING DIODE (L.E.D.)
manual for details on changing the function of the Automation Output.
H/A + H/A - H/A + H/A - H/A + H/A -


transformer. ◆ Use up to 25 feet of 20 AWG or larger
AC AC EXT. SPKR (-) H/A - H/A + RELAY N.O. RELAY DRY
two-conductor wire to connect the transformer to the Console. Route the power wires from the plug-in transformer to the Console. Connect the wires to the transformer terminals (do not plug the transformer in until the wiring is complete). Route the power wires through the Console’s wiring access hole. Connect the power wires from the transformer to the Console’s main terminal block AC & AC terminals. Secure all of the wires entering the Console with a zip-tie to the Console’s strain relief loop. Plug transformer into an unswitched AC outlet. Secure transformer with screw to prevent un-plugging.
BLOCK


PLUG TRANSFORMER INTO AC POWER OUTLET THAT IS NOT CONTROLED BY A LIGHT SWITCH
◆ A 12 volt backup battery may be installed and is
highly recommended. ◆ The backup battery will power the Console for

up to 6 hours during AC power loss. ◆The backup battery is automatically charged by
the Console when AC power is present. ◆A low backup battery will cause the Console
POWER indicator to flash as it is being charged. To install the battery, slide the battery between the retaining clamps and under the battery holder. Position the battery until the clamps snap in place. The battery terminals should be facing the center of the Console case bottom. Connect the black battery lead to the black battery terminal. Connect the red battery lead to the red battery terminal. ✍WARNING: DO NOT REVERSE THE BATTERY
CONNECT RED BATTERY LEAD TO RED TERMINAL CONNECT BLACK BATTERY LEAD TO BLACK TERMINAL

LEADS! THE BATTERY FUSE WILL BLOW.

the Console’s master user code is “1234”.
✍ NOTE: Local programming must be entered on the
Console’s keypad, not on a wireless remote keypad. Press [∗] (clears keypad if any other keys have been pressed). Place the Console in Test Mode (enter 1234 and press [TEST]. ❇A “gong” and four “beeps” will sound.
SETTING A NEW MASTER
SETUP
MODE
USER CODE


Enter the Setup Mode from Test Mode, enter 1234 then press [TEST] again. ❇A “gong” and five “beeps” will sound. You are
now in Setup Mode. Enter 99 then press [HOME]. Enter any combination of 1-5 digits for the master user code, then press [AWAY]. ✍NOTE: For maximum security, a three to five digit
code is recommended. Press and hold the [OFF] key for 3 seconds to exit program mode. Test the new master user code by entering it then pressing [TEST]. Log the master user code in the box below.
✍ NOTE: The master user code can be used to enter
Setup Mode. The restricted user codes cannot. To create restricted user codes, see the “Advanced Programming” section of this manual.
◆ Each wireless sensor that is going to be used
with the Console must be programmed into the Console’s memory. Start with the Console in Test Mode (enter any user code and press [TEST]). Enter the Setup Mode from Test Mode, enter the master user code then press [TEST] again. ❇A “gong” and five “beeps” will sound. You are

now in Setup Mode. ❇The sensor status indicators will light for any
sensors programmed into the Console. Enter an unused sensor number from 01-24 (you must enter two digits, example: 5 = 05) ❇The sensor indicator light will flash for the sensor
number selected. Activate the sensor by sending a test or alarm signal (be sure the sensor’s battery is connected or that its battery protection strip is removed). ❇A single “bing” tone will sound and the sensor
status indicator for that sensor will stay lit. Enter another sensor number or exit Setup Mode by holding the [OFF] key for three seconds.

◆ Follow the instructions on the previous page to
select a sensor number to program the sensor into. ✍NOTE: A sensor can be programmed into more
than one location. Be sure to choose an unused sensor number. If a sensor gets entered into more than one location, delete the duplicates using the remove sensor function. To add DXS-10 wireless keypads, press and hold the keypad’s [∗] key until programmed into the Console. ✍IMPORTANT NOTE: The DXS-31 & DXS-32
door/window sensors are pre-set at the factory for delayed burglary response. If the sensor is going to be used on a non-entry portal (window, sliding glass door, etc.) a jumper can be changed in the sensor to select instant response. The jumper should be changed before learning the sensor so the Console will program the sensor to the proper function. See the “Basic Sensor Installation” section of this manual for details on changing the jumper. For DXS-31 and DXS-32 door/window sensors, move the magnet away from the side of the sensor. For DXS-81, DXS-91, DXS-54, & DXS-72 accessory sensors, simply send a test transmission (refer to the sensor’s instructions for details on sending a test transmission). For DXT-61, DXT-21, DXS-21 & DXT-41 single-button remotes, simply press the unit’s button. The unit will function as an arm/disarm remote. ✍NOTE: After the Console “learns” the transmitter,
single-button remotes can easily be re-programmed as “panic buttons” or home automation controllers. Refer to Page 24 in the “Customizing the System” section of this manual. For DXT-23 & DXT-42 multi-button remotes: Learn the transmitter by pressing the left button. The remote will arm the Console with the left button and disarm with the right. Labels are provided with the DXT-42 for identifying the buttons. ✍NOTE: After the Console “learns” the transmitter,
multi-button remotes can easily be re-programmed to have the left button arm/disarm the Console and the right button activate/deactivate the Home Automation Output. Refer to Page 24 in the “Customizing the System” section of this manual. ❇A single “bing” tone will sound and the sensor
status indicator will stay lit when the sensor is learned by the Console. ❇A double “buzz” tone will sound if there is
LEFT = ARM RIGHT = DISARM BOTH = EMERGENCY
already another sensor programmed to that sensor number. Exit Setup Mode by holding the [OFF] button for two seconds. Reminder: The Console will automatically exit the Setup Mode and return to Off Mode after 3 minutes of keypad inactivity. ✍NOTE: To remove sensors from the Console’s
memory, see Page 22 in the “Customizing the System” section of this manual.


set of installation instructions specific to the model of sensor. ◆Refer to the sensor’s instructions for details on
FROM TOP OF CASE TWIST SCREWDRIVER BETWEEN CASE HALVES UNTIL IT POPS OPEN
installing, operating, and testing of the sensor. ◆Following are basic instructions for installing two
popular DVS-2400 accessories: The Model DXS-10 Wireless Remote Keypad and the Models DXS-31 & DXS-32 Door/Window Transmitters.
◆ The DXS-10 is used to remotely command the
Console. ◆ The keypad can be simply set on a table or
mounted to a flat surface. TABLE-TOP USE
deterrent for the keypad. ✍NOTE: Do not use the adhesive pads if the keypad
is going to be wall mounted. Peel off the adhesive tape backing on the pads and stick them to the back of the keypad. ◆The wireless keypad can be used as a portable
keypad. Because of the hourly supervisory transmissions, if the unit is taken out of range from the Console for more than eight hours, the Console will indicate “radio trouble” for the keypad. The keypad’s sensor number can be programmed for “non-supervised” if required. See the “Advanced Programming” section of this manual. WALL MOUNT USE
USE THE FOUR SCRATCH DETERRENT PADS PROVIDED FOR TABLE-TOP USE

◆The wireless keypad can be wall mounted.
Open the keypad by inserting a small screwdriver in one of the top slots in the keypad case. Gently twist the screwdriver until the case pops open. Attach the rear case to the wall using the two screws provided. ✍NOTE: For best signal transmission, the keypad
should be mounted at least three feet above ground level. Hook the top edge of the keypad case together and snap the keypad onto the rear case. ✍WARNING: The wireless keypad is designed for
ATTACH REAR CASE TO WALL WITH THE TWO SCREWS PROVIDED
indoor use only.
MOUNT AT A CONVENIENT LOCATION NEAR PRIMARY ENTRY/EXIT DOOR

EXAMPLE INSTALLATIONS
◆ The DXS-31 and DXS-32 sensors can be used to
(WITH DXS-31 SHOWN)

monitor doors, windows, cabinets, crawl space doors, gates, freezer doors, and many other moving objects that could be used for intrusion or need to be monitored. ◆A built-in magnetic switch triggers the sensor
when its magnet (mounted on the moving part or the door or window) moves away from the sensor. ◆External normally closed switches (DXS-31
only) can be wired to the sensor for remote triggering. ◆The door/window sensor (DXS-31 only) can
connect directly to a glass break detector. SET SENSOR JUMPER
ANTENNA
◆ A jumper inside the door/window sensor selects
INPUT SELECT JUMPER
MAGNET ALIGNMENT MARK
TWO TYPE 2032 BATTERIES
instant or delayed response. If the sensor is going to be used on the primary entry/exit door make sure that the jumper is in the DELAY position. If the sensor is going to be used on a window or a door that is not going to be used to enter and exit the premises, set the jumper to the INSTANT position. APPLY DOUBLE-STICK TAPE
TRANSMIT INDICATOR
BATTERY CLAMP
TEST SWITCH
EXTERNAL INPUT TERMINALS
INSTANT/DELAY OPTION JUMPER
SELECTS INSTANT
Apply double-stick tape (supplied) to back of sensors and magnets. ◆Screws are also provided to mount sensors and
in permanent installations. ATTACH SENSORS AND MAGNETS
On doors, mount sensor to door frame and magnet to door. ✍NOTE: Magnet must line up with mark on sensor
ATTACH MOUNTING PLATES USING THE SCREWS OR DOUBLE-STICK TAPE PROVIDED
case both horizontally & vertically. Allow a maximum of 1/2" between magnet and sensor when door/window is closed. Snap sensor onto mounting plate. On windows, mount sensor to window frame and magnet to window. Snap sensor onto mounting plate. The magnet height is adjustable and an optional magnet spacer is provided for uneven surfaces.

❇ Console in Chime Mode should “ding-dong”

when the sensor sends signal. Open door or window. ❇Verify that light on the sensor glows momentarily
when door/window is opened. ❇Status indicator on Console should remain lit for
each door/window sensor that is left open.


provided with the Console. ◆ Labeling the sensors allows quick and easy
identification of where any alarms have occurred, where a sensor with a low battery is, where a sensor with radio trouble is, etc.
Use a paper clip to remove the clear display window. Bend down the tabs on the sensor number card and fit it onto the Console. Open one protected door/window to light its sensor status light on the Console. Choose a label that describes the sensor location, or write the location on a blank label, and stick it in the area to the right of the sensor light. Close the protected opening that you just labeled. Repeat for each protected opening. Stick the WIRELESS KEYPAD label in the sensor number location for the wireless keypad (if used). Replace the clear display window when finished.

OPEN DOOR OR WINDOW TO LIGHT SENSOR STATUS INDICATOR ON CONSOLE
APPLY SENSOR IDENTIFICATION LABELS TO THE APPROPRIATE SENSOR LOCATIONS


◆ Use this mode to disarm the burglary portion of
the system. ◆ Switching to Off Mode stops any alarms in
OFF MODE
progress. ◆ The 24-hour functions are still active in Off Mode
START HERE
and can be triggered by pressing the [FIRE] or [EMERGENCY] button. Switch to Off Mode by entering the user code, and pressing [OFF]. ❇When the system is disarmed to Off Mode, the
YOUR USER CODE
Console will sound one “Gong”. ❇If an alarm has occurred, multiple beeps will
sound after disarming and the sensor light for the sensor(s) that caused the alarm will flash. ✍NOTE: In Off Mode, protected doors and windows
cannot trigger the burglary alarm.
OFF
DONE
CHIME MODE
START HERE
CHIME MODE
(OPTIONAL)
◆ Chime Mode is for monitoring entries and exits
without causing alarms. ◆ Use Chime Mode as an “automatic door chime”
when at home. ❇ Opening any protected door or window causes
YOUR USER CODE
the Console to sound a “ding-dong”. Select the Chime Mode by entering a user code, then press [CHIME]. The user can enter Chime Mode from Off Mode by holding down the [CHIME] key for two seconds. ❇When the system is switched to the Chime
CHIME
Mode, the Console will sound a “Gong” and one “Beep”. ◆Going to Chime Mode disarms the system and
OR
stops any alarms in progress. ✍NOTE: In Chime Mode, protected doors and
windows cannot trigger the burglary alarm.
CHIME
1 GONG & 1 BEEP
DONE

MANUAL BYPASSING OF SENSORS
◆ Use this mode when sleeping or when anyone is
◆ Manual bypassing of sensors in the Home Mode
staying inside. ◆ Home Mode causes an instant alarm when any
allows arming of the system at night with open windows, while still having perimeter protection with other closed doors and windows. ◆The Console will resist arming with open door or
perimeter sensor is triggered. ◆Home Mode causes a delayed alarm when any
exit/entry sensor is triggered (except in Home Instant Mode when they are instant). ◆Alarm siren stops automatically after five
something is open and the system will remain in the previous mode. ❇Lit sensor status indicators show which sensors
minutes and the system will remain armed. ◆Home Mode ignores all interior sensors (motion
detectors, etc.). Arm to Home Mode by entering a user code, and pressing [HOME]. The user can “Quick Arm” to Home Mode from Off or Chime Mode by holding down the [HOME] key for two seconds. (Quick arming can be disabled; see the “Advanced Programming” section of this manual.) ❇When the system is armed to the Home Mode,
are open. To manually bypass the open sensors, arm the system again within 5 seconds. ❇A “gong” and two “beeps” will sound, the HOME
indicator will light, and the open sensors will be bypassed. ✍WARNING: Bypassed sensors cannot cause an
alarm.
the Console will sound a “Gong” and two “Beeps”. Enter a user code and press [OFF] or [CHIME] to disarm from Home Mode and/or stop the alarm siren. ❇If an alarm has occurred, multiple beeps will sound
after disarming and the sensor light for the sensor(s) that caused the alarm will flash (switch to Off Mode again or re-arm the Console to stop the flashing alarm memory light).
SECURE EXIT
START IN HOME MODE
SECURE EXIT
If the system is already in the Home Mode and the user wants to exit the premises while leaving someone inside with the system still in Home Mode, enter a user code and press the [HOME] key. ❇A “gong” and two “beeps” will sound and the
(OPTIONAL)
YOUR USER CODE
YOUR USER CODE
HOME light will blink for 60 seconds. No exit delay beeps will sound during the Exit Delay. ◆The user can leave through a door with a delayed
perimeter sensor during the 60 second Exit Delay without causing the Console to begin an Entry Delay. ◆Re-entering during the silent Exit Delay will
1 GONG & 2 BEEPS
DONE
DONE
extend the Exit Delay another 60 seconds (one time only). ✍NOTE: The Exit Delay time can be changed; see
the “Advanced Programming” section of this manual.
QUICK ARM
MODE
If the system is already in the Home Mode and the user wants to make all exit/entry sensors instant, press the [HOME] key for 2 seconds. ❇Two “gongs” and two “beeps” will sound and the
START IN HOME MODE
HOLD DOWN HOME
HOLD DOWN
HOME light will blink continuously. ◆Because all exit/entry sensors will now cause an
2 GONGS & 2 BEEPS
instant alarm when in Home Mode, the Console must be disarmed before opening any exit/entry delay door.
DONE

MANUAL BYPASSING OF SENSORS
◆Use this mode when no one will be staying home. ◆Each burglary sensor can trigger the siren once
allows arming of the system with open doors and windows, while still having perimeter protection with other closed doors and windows. ◆The Console will resist arming with open door or
perimeter sensor is triggered. ◆Away Mode causes a delayed alarm when any
exit/entry sensor is triggered. ◆Away Mode causes an instant alarm when any
something is open and the system will remain in the previous mode. ❇Lit sensor status indicators show which sensors
interior sensors (motion detectors, etc.) are triggered. The interior sensors will be delayed if a perimeter delayed sensor is triggered first. ◆Alarm siren stops automatically after five
are open. To manually bypass the open sensors, arm the system again within 5 seconds. ❇A “gong” and three “beeps” will sound, the
minutes and the system will remain armed. Arm to Away Mode by entering a user code, and pressing [AWAY]. The user can “Quick Arm” to Away Mode from Home, Chime or Off Mode by holding down the [AWAY] key for two seconds. (Quick arming can be disabled; see the “Advanced Programming” section of this manual.)
AWAY indicator will light, and the open sensors will be bypassed. ✍WARNING: Bypassed sensors cannot cause an
alarm.
EXIT DELAY (For Leaving the Premises) ❇When the system is armed to the Away Mode, the
Console will sound a “Gong” and three “Beeps”. ❇During the 60 second Exit Delay, the Console
will sound “beeps” (double beeps last 10 seconds) and the AWAY light will blink. ◆The Exit Delay gives the user 60 seconds to
leave the premises through an exit/entry door without triggering an alarm. ◆Re-entering during the Exit Delay will extend the
Exit Delay another 60 seconds (one time only). ❇When the Exit Delay is over, the Console will
sound one “gong” to warn the user that the system is fully armed. ✍NOTE: The Exit Delay time can be changed; see the
“Advanced Programming” section of this manual.
ENTRY DELAY (For Entering the Premises) ◆The Entry Delay gives the user 30 seconds to
enter the premises through an exit/entry door without triggering an alarm. ◆If a exit/entry sensor is triggered, starting the
Entry Delay, the interior sensors will also become delayed (this allows motion in the premises during the Entry Delay). ❇During the 30 second Entry Delay, the Console will
QUICK ARM
go into full alarm and sound the siren if it is not disarmed to the Off or Chime Mode. ❇If an alarm has occurred while the user was
HOLD DOWN
gone, multiple beeps will sound after disarming and the sensor light for the sensor(s) that caused the alarm will flash (switch to Off Mode again or re-arm the Console to stop the flashing alarm memory light). ✍NOTE: The Entry Delay time can be changed; see the
DONE
“Advanced Programming” section of this manual.

◆ Even though this is a self-monitoring supervised
system, the National Burglar and Fire Alarm Association recommends that all security systems should be tested manually on a regular basis. ◆The Console must be in Off Mode before going
to Test Mode. Switch the Console into Test Mode by entering a user code and pressing [TEST]. ❇When the system is switched to the Test Mode,

the Console will sound a “Gong” and four “Beeps”. Holding down the [TEST] button in Test Mode will light all of the Console’s indicators. ❇The sensor status lights will flash for each sensor
programmed into the Console. Go to each sensor and press its test button or open and close the protected opening. To test the wireless keypad, press the [(A)] key. ❇The Console will make a “bing” sound as each
sensor is tested, followed by 1-3 beeps indicating signal strength with 3 beeps being the strongest signal. ❇As each sensor is tested, the sensor status light
for the sensor will stop flashing and return to showing the current status of the sensor. Continue testing until there are no flashing status lights. ✍NOTE: If the Console is left unattended in Test
Mode, it will automatically switch back to Off Mode after 3 minutes. ◆When directly connecting (without a telephone
line) to the DVS-2400 with the RA-2400 remote access software (Version 1.3 or later), press the [EMERGENCY] key while in Test Mode to cause the Console to connect to the modem.

SENSOR FUNCTION OFF MODE CHIME MODE HOME MODE AWAY MODE
LEFT BUTTON SWITCHES CONSOLE TO AWAY MODE † IF ALARM HAS OCCURED, SWITCHES CONSOLE TO OFF MODE ‡ LEFT BUTTON SWITCHES TO OFF MODE ‡
LEFT BUTTON SWITCHES CONSOLE TO AWAY MODE † IF ALARM HAS OCCURED, SWITCHES CONSOLE TO OFF MODE ‡ RIGHT BUTTON SWITCHES TO OFF MODE ‡
† CAN BE HOME MODE USING PROGRAMMING STEP 50 ‡ CAN BE CHIME MODE USING PROGRAMMING STEP 51 Sensor Function Table

supervised wireless system. ◆If the Console detects a problem with any of the
supervised system sensors or backup battery, it will display the appropriate trouble indication and, if monitored, report the trouble to the Central Station through the communicator (depending on communicator programming).
◆ The Console constantly charges and monitors
POWER INDICATOR

the optional backup battery (if installed). ◆If the backup battery condition is abnormal, the
BLINKS WITH LOW, RECHARGING OR MISSING BACKUP BATTERY
Console’s POWER light will indicate the trouble. ❇The POWER indicator normally glows when AC
DIM WHEN AC POWER IS ABSENT AND CONSOLE IS RUNNING ON BACKUP BATTERY
Console looses AC power, the POWER indicator will dim as the Console runs on the backup battery. ❇If the backup battery is low, recharging, or not
installed, the POWER indicator blinks when AC power is present. ❇If the AC power is off and no backup battery is
installed, the POWER indicator will be off (in this case the system has no power and is disabled). Normal battery life for the type of backup battery used in the Console is 3-4 years. If the battery does not take a charge in 72 hours, it should be replaced.
❇ When the BATTERIES indicator on the Console
BATTERIES INDICATOR
BLINKS WHEN ONE OR MORE SENSORS HAVE A LOW BATTERY
blinks, one or more sensors have a low battery. Press [∗] key for one second to view sensor status. Sensor status indicator for any sensor with a low battery will light along with the BATTERIES indicator. Replace the sensor’s battery as described in their instructions. Switch to Test Mode after replacing the sensor battery and completely test the system (see Test Mode). Switching to Test Mode clears the low battery indication.
LIGHTS WITH SENSOR INDICATOR DURING LOW BATTERY STATUS CHECK (PRESS FOR 1 SECOND)
❇ When the TROUBLE indicator blinks, one or
TROUBLE INDICATOR
more sensors have not reported status during the eight hour status time window. Press [∗] key for one second to view sensor status. Sensor status indicator for any sensor that has not reported in will light along with the TROUBLE indicator. Switch to Test Mode after servicing the sensor and completely test the system (see Test Mode). Switching to Test Mode clears the trouble indication.
BLINKS WHEN ONE OR MORE SENSORS HAVE NOT REPORTED STATUS DURING THE EIGHT HOUR STATUS TIME WINDOW
LIGHTS WITH SENSOR INDICATOR DURING TRANSMITTER STATUS CHECK (PRESS FOR 1 SECOND)

protection provided by the system. ◆ All ground-level perimeter openings and
accessible upper-story openings need protection. ◆Motion detectors can protect interior areas and
areas where valuables are kept.
START IN TEST
Always start with the Console in Test Mode (enter a user code and press [TEST]). Enter the master user code then press the [TEST] button. ❇A “gong” and five “beeps” will sound. ❇The sensor status indicators will light for each
sensor programmed into the Console. Enter an unused sensor number from 01-24 (you must enter two digits, example: 5 = 05). ✍NOTE: A sensor can be learned into more than
TEST
one location. Be sure to choose an unused sensor number. If a sensor gets entered into more than one location, delete the duplicates using the remove sensor function. ❇The sensor indicator light will flash for the sensor
number selected. Activate the sensor. (To add a wireless keypad, press the keypad’s [∗] key.) ❇A single “bing” tone will sound when the sensor
is learned by the Console and the sensor status indicator will stay lit. Enter another sensor number or exit Setup Mode by holding the [OFF] button for three seconds.
REMOVING SENSORS FROM THE SYSTEM
◆ If a previously learned sensor isn’t going to be
used with the system anymore, or it’s a duplicate that has been entered into more than one sensor location, it should be removed from the Console’s memory. ◆Start with the Console in Test Mode.
MASTER USER CODE
Enter the master user code then press the [TEST] button. ❇A “gong” and five “beeps” will sound. ❇The sensor status indicators will light for each
sensor programmed into the Console. Enter the sensor number (from 01-24) that you want to remove (you must enter two digits, example: 5 = 05). ❇The sensor indicator light will flash for the sensor
TEST
SENSOR NUMBER TO REMOVE
number selected. Press the [TEST] button. ❇A single “bing” tone will sound when the sensor
has been removed and the sensor status indicator will turn off. Enter another sensor number or exit Setup Mode by holding the [OFF] button for three seconds.
DONE

START IN TEST
◆ Sensors can be programmed to cause the
Console to chime any time they’re activated. ◆Chime-only sensors will not be able to trigger the
alarm in any Console mode. ◆The sensor must have already been learned by
the Console (see “Adding sensors to the System” for details). Start with the Console in Test Mode. Enter the master user code then press the [TEST] button. ❇A “gong” and five “beeps” will sound. ❇The sensor status indicators will light for each
TEST
SENSOR NUMBER FOR CHIME
sensor programmed into the Console. Enter the sensor number from 01-24 (you must enter two digits, example: 5 = 05). ❇The sensor indicator light will flash for the sensor
number selected. Press [HOME], 8, then [AWAY]. A “bing” tone will sound. Enter another sensor number or exit Setup Mode by holding the [OFF] button for three seconds.
MAKING A SENSOR INTERIOR
1 BING
◆ Motion detectors are automatically programmed
as interior sensors. Any other sensor can also be programmed as an interior sensor. ◆Interior sensors can only trigger an alarm when
the Console is in Away Mode. ◆“Home Interior” sensors can trigger an alarm
when the Console is in the Home or Away mode. ◆The sensor must have already been learned by
the Console (see “Adding sensors to the System” for details). Start with the Console in Test Mode. Enter the master user code then press the [TEST] button. ❇A “gong” and five “beeps” will sound. ❇The sensor status indicators will light for each
sensor programmed into the Console. Enter the sensor number from 01-24 (you must enter two digits, example: 5 = 05). ❇The sensor indicator light will flash for the sensor
TEST
number selected. Press [HOME], 7, then [AWAY]. A “bing” tone will sound. Enter another sensor number or exit Setup Mode by holding the [OFF] button for three seconds.
7 FOR INTERIOR FUNCTION
7 PRS
1 BING
DONE

◆ Sensors can be reprogrammed to perform

the Console (see “Adding Sensors to the System” for details). Start with the Console in Test Mode. Enter the master user code then press the [TEST] button. ❇A “gong” and five “beeps” will sound. ❇The sensor status indicators will light for each
sensor programmed into the Console. Enter the sensor number from 01-24 (you must enter two digits, example: 5 = 05). ❇The sensor indicator light will flash for the sensor
number selected. Choose a function number from the Sensor Function Table. Press [HOME], the new function number, then [AWAY]. A “bing” tone will sound. Enter another sensor number or exit Setup Mode by holding the [OFF] button for three seconds.

# SENSOR FUNCTION OFF MODE CHIME MODE HOME MODE AWAY MODE
3 PANIC ARMED 24-HOURS - TRIGGERS SILENT PANIC ALARM
9 2-BUTTON ARM/DISARM (LEFT) 2-BUTTON AUTOMATION (RIGHT) EMERGENCY (BOTH)
LEFT BUTTON SWITCHES CONSOLE TO AWAY MODE † IF ALARM HAS OCCURED, SWITCHES CONSOLE TO OFF MODE ‡ LEFT BUTTON SWITCHES TO OFF MODE ‡
10 2-BUTTON ARM (LEFT) 2-BUTTON DISARM (RIGHT) EMERGENCY (BOTH)
LEFT BUTTON SWITCHES CONSOLE TO AWAY MODE † IF ALARM HAS OCCURED, SWITCHES CONSOLE TO OFF MODE ‡ RIGHT BUTTON SWITCHES TO OFF MODE ‡
† CAN BE HOME MODE USING PROGRAMMING STEP 50 ‡ CAN BE CHIME MODE USING PROGRAMMING STEP 51 Sensor Function Table

steps, the Console must be in the Setup Mode. ◆Each programming function is performed with
Start with the Console in Test Mode (Setup Mode cannot be reached from any other mode). From Test Mode, enter the master user code then press [TEST]. ✍NOTE: Only the master user code can be used to
similar keystrokes. After the Console is in Setup Mode, enter the programming step number, press the [HOME] key (HOME = program), enter the new value, and press the [AWAY] key (AWAY = store). Follow the figures next to the programming steps.
put the Console into the Setup Mode. The restricted user codes cannot access Setup Mode. ❇A “gong” and five “beeps” will sound, signaling
that the Console is in Setup Mode. Hold the [OFF] key for three seconds when you want to exit Setup Mode. ✍NOTE: If the Console is left unattended in Setup
AWAY = STORE
Mode, it will automatically switch back to Off Mode after three minutes.
STEP # PROGRAMMING FUNCTION POSSIBLE VALUES FACTORY VALUE INSTALLATION VALUE
26 EXIT DELAY 20-255 SECONDS 60
30 BURGLARY SIREN TIME 1-30 MINUTES 5
31 EMERGENCY SIREN TIME 1-30 MINUTES 5
32 FIRE SIREN TIME 1-30 MINUTES 5
40 AUTOMATION OUTPUT TIME 0-2500 SECONDS (0 = TOGGLE ON/OFF) 0
50 REMOTE ARMING MODE 2 = HOME MODE; 3 = AWAY MODE 3
51 REMOTE DISARMING MODE 0 = OFF MODE; 1 = CHIME MODE 0
61 ENTRY DELAY BEEPS 0 = OFF; 1 = ON 1
62 EXIT DELAY BEEPS 0 = OFF; 1 = ON 1
63 SILENT BURGLARY ALARM 0 = AUDIBLE; 1 = SILENT 0
64 SILENT EMERGENCY ALARM 0 = AUDIBLE; 1 = SILENT 0
65 QUICK ARMING 0 = OFF; 1 = ON 1
66 AUTO RESTORE 0 = OFF; 1 = ON 1
67 AUTO BYPASS 0 = OFF; 1 = ON 0
68 AUTOMATION MODE DURING ALARM 0 = FLASH (ENABLED BY FUNCTION 72) 1 = STEADY (ENABLED BY FUNCTION 72) 0
69 AUTOMATION BING TONE 0 = NO BINGS 1 = BINGS 1
70 REMOTE ARM/DISARM CHIRP 0 = NO CHIRPS 1 = CHIRPS (1 CHIRP = ARMED, 2 CHIRPS = DISARMED) 1
71 AUTOMATION FLASHES AFTER ALARM 0 = STANDARD 1 = FLASHING AFTER ALARM 0
0 = STANDARD 1 = AUTOMATION ACTIVE DURING ALARM (FLASH OR STEADY PROGRAMMED BY FUNCTION 68)
73 AUTOMATION ON WHILE ARMED 0 = STANDARD 1 = ON WHILE ARMED 0
74 AUTOMATION ON DURING EXIT/ENTRY 0 = STANDARD 1 = ON DURING EXIT/ENTRY DELAYS 0
75 AUTOMATION POLARITY 0 = + WHEN OFF; 1 = + WHEN ON 1
92 DURESS CODE 1-5 DIGITS REMOVED
93 RESTRICTED USER CODE #1 1-5 DIGITS REMOVED
94 RESTRICTED USER CODE #2 1-5 DIGITS REMOVED
95 RESTRICTED USER CODE #3 1-5 DIGITS REMOVED
96 RESTRICTED USER CODE #4 1-5 DIGITS REMOVED
97 RESTRICTED USER CODE #5 1-5 DIGITS REMOVED
98 PAGE ALERT USER CODE 1-5 DIGITS REMOVED
99 MASTER USER CODE 1-5 DIGITS 1234
Console Programming Table

◆ When a sensor is programmed, the Console sets
SENSOR NUMBER TO CHANGE
all stationary sensors as supervised, and all portable sensors as non-supervised. ◆The Console expects hourly status transmissions
from any sensor programmed as supervised. ◆Any sensor can be programmed as supervised
or non-supervised. ✍ NOTE: Don’t program a sensor that doesn’t send
status transmissions as supervised.
◆ When a sensor is programmed, the Console
SENSOR NUMBER TO CHANGE
automatically recognizes it as manually or automatically restoring. ◆The Console expects restoral signals from any
sensor programmed as manual restore. ◆Any sensor can be programmed as manual or
automatic restore. ✍ NOTE: Don’t program a sensor that doesn’t send
restoral transmissions as manual restore.
◆The factory-set Entry Delay time is 30 seconds. ◆The Entry Delay time can be adjusted from 20 to
JKL
255 seconds. ✍ NOTE: Don’t make the Entry Delay too short. The
user may not have enough time to disarm the system before an alarm. Write the new Entry Delay time in the User’s Guide.
EXIT DELAY TIME
◆The factory-set Exit Delay time is 60 seconds. ◆The Exit Delay time can be adjusted from 20 to
255 seconds. Write the new Exit Delay time in the User’s Guide.
BURGLARY SIREN TIME
◆ The factory-set burglary siren time is five
3 DEF
PROGRAMMING STEP #30
minutes. ◆ The burglary siren time can be adjusted from
one to 30 minutes.
EMERGENCY SIREN TIME
◆ The factory-set emergency siren time is five
3 DEF
PROGRAMMING STEP #31
minutes. ◆ The emergency siren time can be adjusted from
one to 30 minutes.

◆The factory-set fire siren time is five minutes. ◆The fire siren time can be adjusted from one to
PROGRAMMING STEP #32
2 ABC
30 minutes.
AUTOMATION OUTPUT TIME
◆ The factory setting causes the Automation Output
4 GHI
PROGRAMMING STEP #40
to toggle between on and off with each activation. ◆The Automation Output can be programmed to
turn on, then automatically turn off after one to 2500 seconds (42 minutes).
TIME IN SECONDS (1-2500) 0 = TOGGLE ON & OFF
◆ The factory setting causes the portable remote
5 JKL
controls to arm to the Away Mode. ◆Alternately, the portable remote controls can
arm to the Home Mode. ◆Changing this setting will affect all the portable
remote controls used with the system.
◆ The factory setting causes the portable remote
5 JKL
controls to disarm to the Off Mode. ◆Alternately, the remote controls can disarm to
the Chime Mode. ◆ Changing this setting will affect all the portable
0 FOR OFF MODE 1 FOR CHIME MODE
remote controls used with the system.
◆ The factory setting causes the Console to beep
6 MNO
during Entry Delays. ◆Alternately, the Entry Delay beeps can be silenced. ◆With the Entry Delay beeps off, the Console will
be silent after a delayed sensor is triggered until the Entry Delay expires, then the alarm siren will sound.
0 FOR ENTRY BEEPS OFF 1 FOR ENTRY BEEPS ON
◆ The factory setting causes the Console to beep
6 MNO
during Exit Delays. ◆Alternately, the Exit Delay beeps can be silenced. ◆With the Exit Delay beeps off, the Console will be
2 ABC
silent after arming to the Away Mode until the Exit Delay expires, then a single “gong” tone will sound.
0 FOR EXIT BEEPS OFF 1 FOR EXIT BEEPS ON

◆ The factory setting causes audible burglary
6 MNO
alarms. ◆ Alternately, the Console can be programmed for
PROGRAMMING STEP #63
3 DEF
silent burglary alarms.
SILENT EMERGENCY ALARMS
◆ The factory setting causes audible emergency
6 MNO
alarms. ◆ Alternately, the Console can be programmed for
PROGRAMMING STEP #64
4 GHI
silent emergency alarms.
DISABLING QUICK ARMING
◆ The factory setting allows the Console to be
6 MNO
armed by holding down the mode keys for two seconds. ◆Alternately, the Console can be programmed to
5 JKL
not allow quick arming. ◆If quick arming is disabled, a user code must be
0 FOR QUICK ARMING OFF 1 FOR QUICK ARMING ON
entered before pressing the mode buttons. ✍NOTE: For commercial installations, it is
recommended to disable quick arming to prevent customers from arming the system. ✍NOTE: If quick arming is disabled the Home
Instant Mode is unavailable.
◆ Bypassed sensors are ignored by the Console
6 MNO
and cannot cause an alarm. ◆The factory setting causes the Console to
6 MNO
automatically restore any bypassed sensor when the sensor closes. After it’s restored, the sensor is ready to cause an alarm the next time it is opened. ◆Alternately, the Console can be programmed to
0 FOR AUTO RESTORAL OFF 1 FOR AUTO RESTORAL ON
not automatically restore (remove the bypass from) sensors that close. Bypassed sensors will remain bypassed until the system is disarmed.
◆ The factory setting requires the user to manually
bypass any open sensors when the system is armed. ◆If arming is attempted with open sensors, the
PROGRAMMING STEP #67
7 PRS
Console will sound five two-tone beeps and will not arm. ◆Arming to the same mode again within five
0 FOR AUTO BYPASS OFF 1 FOR AUTO BYPASS ON
seconds will bypass any open sensors and arm the Console. ◆Alternately, the Console can be programmed to
automatically bypass any open sensors when the system is armed.

✍ NOTE: For the Automation Output to activate
6 MNO
during an alarm, that function must be enabled with Programming Step 71 or 72. ◆If the Automation output is programmed to
8 TUV
activate during an alarm, it can be programmed to flash or be steady.
0 FOR FLASHING OUTPUT ON ALARM 1 FOR STEADY OUTPUT ON ALARM
◆ The factory setting causes the Console to sound
a “bing” when the Automation Output is activated by pressing the [(A)] key, or when it’s triggered with a two-button remote control. ◆Alternately, this sound can be silenced.
PROGRAMMING STEP #69
9 WXY
0 FOR BING TONE OFF 1 FOR BING TONE ON
◆ When arming with the portable remote control,
7 PRS
the factory setting causes the Console to “chirp” once when armed, twice when disarmed, and three times when arming with sensors bypassed. ◆Alternately, these chirps can be silenced. ✍NOTE: If these chirps are silenced, it is
0 FOR CHIRPS OFF 1 FOR CHIRPS ON
recommended to program the Automation Output to be active when the system is armed, so a light can be triggered displaying the arming status of the Console.
◆ The factory setting causes the Console’s
7 PRS
Automation Output to activate when pressing the [(A)] key, or when it’s triggered with a two-button remote control. ◆In addition, the Console can be programmed to
0 FOR STANDARD TRIGGER 1 FOR FLASHING DURING & AFTER ALARM
flash the Automation Output during and after any alarms. ◆The output will continue to flash until the flashing
status lights are cleared.
◆ The factory setting causes the Console’s
7 PRS
Automation Output to activate when pressing the [(A)] key, or when it’s triggered with a two-button remote control. ◆In addition, the Console can be programmed to
2 ABC
0 FOR STANDARD TRIGGER 1 FOR OUTPUT DURING ALARM
activate the Automation Output during alarms. ✍NOTE: The Automation Output can be
programmed to flash or be steady during alarm, see Programming Step 68.

◆ The factory setting causes the Console’s
7 PRS
PROGRAMMING STEP #73
Automation Output to activate when pressing the [(A)] key, or when it’s triggered with a two-button remote control. ◆In addition, the Console can be programmed to
0 FOR STANDARD TRIGGER 1 FOR OUTPUT WHEN ARMED
activate the Automation Output when the system is armed.
◆ The factory setting causes the Console’s
7 PRS
PROGRAMMING STEP #74
Automation Output to activate when pressing the [(A)] key, or when it’s triggered with a two-button remote control. ◆In addition, the Console can be programmed to
0 FOR STANDARD TRIGGER 1 FOR OUTPUT DURING EXIT/ENTRY DELAYS
activate the Automation Output during the exit and Entry Delays.
◆ The factory setting causes the Console’s
7 PRS
PROGRAMMING STEP #75
Automation Output to provide a current limited voltage source when activated. ◆Alternately, the Console can be programmed so
0 FOR VOLTAGE WHEN OFF 1 FOR VOLTAGE WHEN ON
the Automation Output provides a current limited voltage source when deactivated.
◆ This is the password used to gain access to the
8 TUV
PROGRAMMING STEP #87
7 PRS
Console when using the RA-2400 remote access software. ◆The password must be 6-digits long.
Log the remote access password in the box below.
DURESS CODE
◆ The duress code will disarm the system, without
9 WXY
PROGRAMMING STEP #92
2 ABC
any special indications or sounds, but will send the programmed duress code to the Central Station. ◆The duress code should be two or more digits
different than any user code. Log the duress code in the box below.
MASTER USER CODE
◆ The master user code is 1234 when power is first
9 WXY
9 WXY
PROGRAMMING STEP #99
applied to the Console. ◆The master user code can be changed through
programming to any 1-5 digit code. Only the master user can access Setup Mode, restricted users cannot. ✍NOTE: For maximum security, a 3-5 digit code is
recommended. Log the master user code in the box below.

◆ The Console can be programmed with five
PROGRAMMING STEPS #93 TO 98
restricted user codes and one page alert user code. ◆The restricted user codes operate the system as
usual, but cannot access Setup Mode. ◆The restricted user codes can access a special
Code Mode that can be used to change or remove any of the five restricted user codes, the page alert user code, or the duress code. ◆The page alert user code dials the supervisory
number (programmed for a pager) when it is used to ARM OR DISARM the system. ◆A restricted user code is a good one to give to
STEP # 94 RESTRICTED USER CODE #2
STEP # 95 RESTRICTED USER CODE #3
children or any user that should be restricted from programming the Console. ✍NOTE: For maximum security, a 3-5 digit code is
STEP # 97 RESTRICTED USER CODE #5
recommended. ✍ WARNING: NEVER PROGRAM ANY RESTRICTED
STEP # 98 PAGE ALERT USER CODE
OR PAGE ALERT USER CODE THE SAME AS THE MASTER USER CODE! Log the restricted user codes in the boxes.

can be removed from the Console. ◆Because access to programming would be
impossible without a master user code, it cannot be removed using these steps. ◆The master user code can be changed using
using the Console master reset, although all other system programming with be reset to factory values and all sensors programmed will be erased.
◆ Master resetting the Console will set all of the
START IN TEST
programming options back to the factory values. The master user code will be reset to 1234. ✍CAUTION: Master resetting the Console will erase
the user codes and remove all programmed sensors. All Console and communicator programming values will be reset to the factory defaults. Start with the system in Test Mode (Setup Mode cannot be reached from any other mode). From the Test Mode, enter the master user code then press [TEST]. ❇A “Gong” and five “Beeps” will sound, signaling
TEST
9 WXY
STEP #999 FOR MASTER RESET
9 WXY
USE THESE EXACT KEYSTROKES TO PERFORM A MASTER RESET
that the system is in Setup Mode. Enter programming Step #999. Press [TEST]. Enter the numbers 999 again. Press [TEST] again. ❇A “Bing” will sound to indicate the beginning of
PRESS TEST
TEST
9 WXY
ENTER 999 TO OK THE MASTER RESET
the reset process. This process will take up to 10 seconds while the memory is being reset. ◆The system will revert to the first time power-up
9 WXY
condition and the new master user code will be 1234. Go to the “Basic Console Programming” section of this manual to begin re-programming the system.
PRESS TEST, 1 BING SOUNDS, WAIT ABOUT 10 SECONDS
DONE

◆ To perform any of the communicator
programming steps, the Console must be in the Setup Mode. ◆Each programming function is performed with
similar keystrokes. After the Console is in Setup Mode, enter the programming step number, press the [HOME] key (HOME = program), enter the new value, and press the [AWAY] key (AWAY = store). Follow the figures next to the programming step. Start with the Console in Test Mode (Setup Mode cannot be reached from any other mode). From Test Mode, enter the master user code then press [TEST]. ✍NOTE: Only the master user code can be used to
MASTER USER CODE
put the Console into the Setup Mode. The restricted user codes cannot access Setup Mode. ❇A “gong” and five “beeps” will sound, signaling
that the Console is in Setup Mode. Hold the [OFF] key for three seconds when you want to exit Setup Mode. ✍NOTE: If the Console is left unattended in Setup
Mode, it will automatically switch back to Off Mode after three minutes.
STEP # PROGRAMMING
POSSIBLE
FACTORY
INSTALLATION
FUNCTION
VALUES
VALUE
VALUE
76 2-WAY AUDIO 0 = NONE; 1 = LISTEN; 2 = 2-WAY MANUAL; 3 = 2-WAY FULL DUPLEX 0
78 VOICE RESPONSE FROM CONSOLE SPEAKER (AND REMOTE SPEAKER IF USED)
0 = VOICE RESPONSE DISABLED 1 = VOICE RESPONSE ENABLED 0
100 REMOTE PROGRAMMING LOCKOUT 0 = UNLOCK; 1 = LOCK 0
101 CALL LIMITER 0 = OFF; 1 = FIVE CALLS PER ARMING PERIOD 0
103 DIALING DELAY 0 = NO DELAY; 1 = 30 SECOND DELAY 0
104 DIALING METHOD 0 = TONE; 1 = PULSE 0
107 COMMUNICATOR ENABLE 0 = COMMUNICATOR OFF, 1 = COMMUNICATOR ON 0
General Communicator Programming Table

COMMUNICATOR ENABLE
◆ The factory setting for the Console disables the
PROGRAMMING STEP #107
communicator. If the system is going to be a non-monitored, local alarm only, leave the communicator disabled. ◆If the system is going to be monitored by a
0 FOR COMMUNICATOR OFF 1 FOR COMMUNICATOR ON
Central Station, enable the communicator with this programming step.
PROGRAMMING STEP #76
the communicator can provide 2-way audio capability. ◆The audio module can be programmed for listen
0 FOR NO AUDIO MONITORING 1 FOR LISTEN-ONLY 2 FOR 2-WAY MANUAL 3 FOR 2-WAY FULL DUPLEX
only, 2-way manual operation (using a pushbutton telephone at the Central Station), and 2-way full duplex hands free operation. ◆Refer to the VB-2 installation instructions for
details on operating the audio module. ✍NOTE: The Model VB-2 Digital Voice Synthesis
module must be installed for this option to function. ◆The factory setting for the VB-2 audio module is
listen-only, (2) 2-way manual, (3) 2-way full duplex. ✍NOTE: Units programmed for two-way duplex can
still be controlled manually by pressing the “1" or ”3" key. In addition, the Central Station can return the unit to two-way duplex by pressing the “8" key.
◆ The Console can be programmed to allow its
7 PRS
PROGRAMMING STEP #78
speaker to play audio produced by the VB-2 or VB-3 digital voice synthesis modules. ◆This selection can also be used when a remote
speaker is connected to the Console. ◆The factory setting is to disable the Console’s
0 FOR NO VOICE RESPONSE 1 FOR VOICE RESPONSE
speaker from playing voice module audio. ◆Alternately, the Console can be programmed to
programming step will only effect the audio produced by the voice module. It will not stop the Console’s speaker from sounding local sirens and tones. ✍NOTE: A Model VB-2 or VB-3 Digital Voice
Synthesis module must be installed for this option to function.
◆ The factory setting for the communicator is to
PROGRAMMING STEP #100
allow remote connection to the Console with Linear’s RA-2400 Remote Access Software and a modem (unlocked). ◆Alternately, the Console can be programmed to
not answer incoming calls, thereby, not allowing remote access (locked).

◆The factory setting for the call limiter is OFF.
This allows the communicator to report burglary alarms, once for each sensor, as many times as they are triggered. ◆Optionally, the Console can be programmed to
only allow five burglary reports total per arming period. ✍NOTE: Sensors programmed to 24-hour functions
0 FOR OFF (UNLIMITED) 1 FOR ON (5 VIOLATIONS)
(Emergency, Panic, Fire) always send a Central Station Report and always sound the local siren regardless of the Call Limiter setting.
◆ The factory setting will cause the communicator
to dial the Central Station instantly when an alarm or supervisory event occurs. ◆Alternately, the communicator can be
programmed to wait 30 seconds before dialing. This gives the user time to disarm the system and prevent communications in the case of a subscriber generated false alarm.
0 FOR NO DELAY 1 FOR 30 SECOND DELAY
◆ The factory setting causes the communicator to
dial using DTMF (dual-tone multi-frequency) tone dialing. ◆Alternately, the communicator can be
4 GHI
programmed to use pulse (rotary) dialing. Use this option if the telephone line in the installation does not support tone dialing.

REPORTING FORMAT
◆ The factory setting causes the communicator to
report using the 4 by 2 format. This format allows four-digit account numbers from 0000 to 9999 and provides two-digit alarm codes. ◆Alternately ADEMCO CONTACT ID can be
5 JKL
chosen as a reporting format. This format allows 4-digit account numbers from 0000 to 9999 and provides verbose report descriptions with Ademco Contact ID compatible Central Stations.
0 FOR 4 BY 2 1 FOR ADEMCO CONTACT ID
◆ The factory setting for the communicator is to
route all calls to the primary telephone number. If communication is unsuccessful after five attempts to the primary number, the secondary number will be dialed for an additional five attempts. If the secondary number cannot be reached, the communicator will “sleep” for five minutes before starting the call process over again. A total of five sleep cycles (50 call attempts) can occur before the communicator stops calling. ◆Alternately, the communicator can be
PROGRAMMING STEP #86
6 MNO
0 FOR ALL TO PRIMARY/SECONDARY 1 FOR ALARMS ONLY TO PRIMARY/SECONDARY
programmed to report supervisory events (low batteries, radio trouble, etc.) to the supervisory telephone number instead of the primary or secondary telephone numbers. ✍CAUTION: If the page alert user code feature is
going to be used, the supervisory number is reserved for the pager number. DO NOT SET THE CALL ROUTING OPTION TO “1”. ◆To disable supervisory reports, set call routing
option to “1” and remove the supervisory telephone number or in 4 by 2 set the report to 0. ✍NOTE: Do not program the primary and secondary
telephone numbers the same. See the FCC Telephone Rules and Regulations on the rear cover of this manual.
STEP # PROGRAMMING
POSSIBLE
FACTORY
INSTALLATION
FUNCTION
VALUES
VALUE
VALUE
0 = ALL CALLS TO PRIMARY OR SECONDARY NUMBER 1 = ALL ALARM CALLS TO PRIMARY OR SECONDARY NUMBER AND ALL OTHERS TO SUPERVISORY NUMBER
88 ACCOUNT NUMBER 4 DIGITS EMPTY
89 PRIMARY PHONE NUMBER UP TO 20 DIGITS EMPTY
90 SECONDARY PHONE NUMBER UP TO 20 DIGITS EMPTY
91 SUPERVISORY/ PAGER PHONE NUMBER UP TO 20 DIGITS EMPTY
PRESSING THE (A) KEY INSERTS A 1-SECOND DELAY THE [FIRE] KEY INSERTS A 5-SECOND DELAY THE [CHIME] KEY INSERTS A “*” THE (A) KEY INSERTS A “#” IF IT IS THE LAST DIGIT OF THE PHONE NUMBER
105 REPORTING FORMAT 0 = 4 BY 2; 1 = ADEMCO 0
108 REPORT CONSOLE TROUBLE 0 = NO; 1 = YES 0
110 REPORT FORCE ARMING 0 = NO; 1 = YES 0
111 OPEN/CLOSE 0 = NO; 1 = YES; 2 = MASTER PAC ONLY 0
113 POINT ID REPORTING FOR 4 BY 2 FORMAT 0 = NO; 1 = YES 1
Communicator Reporting Option Table

◆ The communicator’s account number entered
8 TUV
must be 4-digits long. ◆The factory setting for the account number is
8 TUV
0000. ◆Enter an account number from 0000 to 9999.
PRIMARY TELEPHONE NUMBER
◆ The primary Central Station telephone number
8 TUV
PROGRAMMING STEP #89
can be up to 20-digits long. ◆Digits 0-9 can be used. ◆Delays and special characters can be entered in
the telephone number (see below).
SECONDARY TELEPHONE NUMBER
◆ The secondary Central Station telephone
9 WXY
number can be up to 20-digits long. ◆Digits 0-9 can be used. ◆Delays and special characters can be entered in
the telephone number (see below). ✍ NOTE: To remove the secondary telephone
ENTER UP TO 20 DIGITS FOR SECONDARY NUMBER
number, program Step # then press [TEST].
◆ The supervisory Central Station or pager
telephone number can be up to 20-digits long. ◆Digits 0-9 can be used. ◆Delays and special characters can be entered in
PROGRAMMING STEP #91
the telephone number (see below). ✍ NOTE: To remove the supervisory/page alert
ENTER UP TO 20 DIGITS FOR SUPERVISORY NUMBER
telephone number, program Step # then press [TEST]. ◆If this is a pager number, enter enough delays
(see the number delays and special characters) for the phone to answer. Then enter the number to be dialed. ◆End Page Alert with the completion character,
usually A (#).
◆ When creating telephone numbers with
ADDS A 1-SECOND DELAY (START OR MIDDLE OF NUMBER)
programming Steps 89, 90, & 91, use the following keys to add dialing delays or special characters. ◆Press the (A) key to place a 1-second dialing
ADDS A 5-SECOND DELAY (ANYWHERE IN NUMBER)
delay at the start or anywhere in the middle of the telephone number. ◆Pressing the (A) key as the last digit of the
ADDS A STAR ( ) CHARACTER (ANYWHERE IN NUMBER)
telephone number will place a pound (#) character at the end of the telephone number. ◆Press the [FIRE] key to place a 5-second dialing
delay anywhere in the telephone number. ◆Press the [CHIME] key to place a star (*
) character anywhere in the telephone number.

◆ The factory setting does not report Console
trouble events to the Central Station. ◆ Alternately, the communicator can be
PROGRAMMING STEP #108
programmed to report Console trouble events. These include all conditions that light the Console’s BATTERIES or TROUBLE indicator. It also includes low Console backup battery.
0 FOR NO CONSOLE TROUBLE 1 FOR CONSOLE TROUBLE
◆ The factory setting does not send force arming
reports. ◆ Alternately, the communicator can be
PROGRAMMING STEP #110
programmed to report force arming anytime the Console is armed with one or more bypassed sensors. ◆The factory set reporting code for force arming is
0 FOR NO FORCE ARMING RPTS. 1 FOR FORCE ARMING RPTS.
“65” (Code 574 with Ademco). ✍NOTE: If force arming is enabled, and the Console
is force armed (armed with an open sensor) remotely by telephone, or with the RA-2400 Remote Access software, the caller will be disconnected if the communicator is enabled.
◆ The factory setting does not send opening and
closing reports ◆ Alternately, the communicator can be
PROGRAMMING STEP #111
programmed to send an opening report when the system is disarmed, and a closing report when the system is armed for all users, or just the master user. ✍NOTE 1: For commercial installations using
0 FOR NO OPEN/CLOSE REPORTS 1 FOR O/C RPTS. FOR ALL USERS 2 FOR O/C RPTS. FROM MASTER USER ONLY
opening and closing reports, it is recommended to disable quick arming to prevent customers from arming the system. ✍NOTE 2: The reporting codes are fixed for opening
and closing. A unique code is reserved for the master user code and each of the five restricted user codes. ✍NOTE 3: Arming or disarming with the page alert
user code dials the supervisory number, no opening or closing report is sent.
◆ The factory setting enables Point ID and allows
the communicator to send two-digit alarm and trouble codes for each sensor. The individual sensor that causes an alarm or trouble report can be identified at the Central Station. ◆Alternately, Point ID can be disabled. The Central
Station will only receive general alarm and trouble reports.
0 FOR GENERAL REPORTS ONLY 1 FOR POINT ID REPORTING

◆ The two-digit communicator reporting code for
each event has a factory set value. These values may be customized to fit the specific installation and the reporting requirements of the Central Station monitoring the system. ◆If Point ID reporting is enabled (the factory
default setting), each sensor can report a unique alarm and trouble code. ◆If Point ID is disabled, the “general” reporting
codes for each event type will be used. ◆Each programming function is performed with
similar keystrokes. After the Console is in Setup Mode, enter the programming step number, press the [HOME] key (HOME = program), enter the new value, and press the [AWAY] key (AWAY = store). ◆Making a value 0 causes event to not
communicate to central station. ✍NOTE: The reporting codes are fixed for opening
and closing. A unique code is reserved for the master and the five restricted user codes. See the Opening & Closing Reporting Codes Table.
◆ Program Steps #201 - 206 for the communicator
reporting codes when Point ID is disabled. ◆Refer to the Console & General Reporting Codes
table to view/edit the reporting codes for each of the five events. The factory settings are listed, along with a blank area to write in the new installation values. ◆Any value from 0-99 can be programmed for
PROGRAMMING STEPS #201 TO #206
each event (0 = no report). ✍NOTE: Be careful not to duplicate codes unless
the Central Station requires specific codes for certain types of events.
◆ Program Steps #261 - 266 for the Console
reporting codes. ◆ Refer to the System Reporting Codes table to
2 ABC
PROGRAMMING STEPS #261 TO #266
6 MNO
view/edit the reporting codes for the keypad [FIRE] and [EMERGENCY] buttons and for each of the four Control Panel conditions. The factory settings are listed, along with a blank area to write in the new installation values.
GENERAL REPORTING CODES
STEP # PROGRAMMING
POSSIBLE
FACTORY
INSTALLATION
FUNCTION
VALUES
VALUE
VALUE
201 GENERAL FIRE REPORT CODE 0 - 99 1
202 GENERAL EMERGENCY REPORT CODE 0 - 99 2
203 GENERAL SILENT PANIC REPORT CODE 0 - 99 3
204 GENERAL BURGLARY REPORT CODE 0 - 99 4
206 GENERAL TROUBLE REPORT CODE 0 - 99 6
General Reporting Codes Table


◆Programming Step #258 ◆The factory set reporting code for force arming is
“65” (Code 574 with Ademco). ◆Any value from 0-99 can be programmed for
this event (0 = no report). ✍NOTE: For force arming reporting, force arming
◆Programming Step #259 ◆The factory set reporting code for Duress is “66”
(Code 121 with Ademco). ◆Any value from 0-99 can be programmed for
this event (0 = no report). ✍NOTE: For duress code reporting a keypad duress

POSSIBLE 4 x 2 VALUES FACTORY 4 x 2 VALUE ADEMCO
261 SYSTEM FIRE REPORT CODE 0 - 99 68 110
262 SYSTEM EMERGENCY REPORT CODE 0 - 99 69 120
263 SYSTEM TEST/CANCEL REPORT CODE 0 - 99 70 406
264 SYSTEM LOW BATTERY RESTORAL REPORT CODE 0 - 99 71 R302
266 SYSTEM LOW BATTERY REPORT CODE 0 - 99 73 E302
258 FORCE ARMING REPORT CODE 0 - 99 65 574
259 DURESS REPORT CODE 0 - 99 66 121
System Reporting Codes Table

MASTER USER CODE 74 82 R401 C000 E401 C000
RESTRICTED USER CODE #1 75 83 R401 C001 E401 C001
RESTRICTED USER CODE #2 76 84 R401 C002 E401 C002
RESTRICTED USER CODE #3 77 85 R401 C003 E401 C003
RESTRICTED USER CODE #4 78 86 R401 C004 E401 C004
RESTRICTED USER CODE #5 79 87 R401 C005 E401 C005
PAGE ALERT USER CODE (DIALS PAGE NUMBER ONLY, NO CODES REPORTED)
REMOTE/HARDWIRE ARM (SENSOR TYPE 9) & QUICK ARM 81 R407 C007
Opening & Closing Reporting Codes Table

4 BY 2 FORMAT POINT ID ALARM REPORT CODES ◆Refer to the 4 by 2 Format Point ID Reporting
Code table to view/edit the alarm reporting codes for each of the 24 sensors. The communicator will send these codes if Point ID is enabled and any sensor triggers an alarm. The factory settings are listed, along with a blank area to write in the new installation values. ✍NOTE: Be careful not to duplicate codes unless
PROGRAMMING STEPS #210 TO #233
the Central Station requires specific codes for certain types of sensors. ◆Each programming function is performed with
similar keystrokes. After the system is in Setup Mode, enter the programming step number, press the [HOME] key (HOME = program), enter the new value, and press the [AWAY] key (AWAY = store).
4 BY 2 FORMAT POINT ID TROUBLE REPORT CODES ◆Refer to the 4 by 2 Format Point ID Reporting
Code table to view/edit the trouble reporting codes for each of the 24 sensors. The communicator will send these codes if Point ID is enabled and any sensor has a low battery or trouble condition. The factory settings are listed, along with a blank area to write in the new installation values. ✍NOTE: Be careful not to duplicate codes unless
PROGRAMMING STEPS #234 TO 257
the Central Station requires specific codes for certain types of sensors. ◆Each programming function is performed with
similar keystrokes. After the Console is in Setup Mode, enter the programming step number, press the [HOME] key (HOME = program), enter the new value, and press the [AWAY] key (AWAY = store).


210 SENSOR 1 ALARM REPORT CODE 0 - 99 11
211 SENSOR 2 ALARM REPORT CODE 0 - 99 12
212 SENSOR 3 ALARM REPORT CODE 0 - 99 13
213 SENSOR 4 ALARM REPORT CODE 0 - 99 14
214 SENSOR 5 ALARM REPORT CODE 0 - 99 15
215 SENSOR 6 ALARM REPORT CODE 0 - 99 16
216 SENSOR 7 ALARM REPORT CODE 0 - 99 17
217 SENSOR 8 ALARM REPORT CODE 0 - 99 18
218 SENSOR 9 ALARM REPORT CODE 0 - 99 19
219 SENSOR 10 ALARM REPORT CODE 0 - 99 20
220 SENSOR 11 ALARM REPORT CODE 0 - 99 21
221 SENSOR 12 ALARM REPORT CODE 0 - 99 22
222 SENSOR 13 ALARM REPORT CODE 0 - 99 23
223 SENSOR 14 ALARM REPORT CODE 0 - 99 24
224 SENSOR 15 ALARM REPORT CODE 0 - 99 25
225 SENSOR 16 ALARM REPORT CODE 0 - 99 26
226 SENSOR 17 ALARM REPORT CODE 0 - 99 27
227 SENSOR 18 ALARM REPORT CODE 0 - 99 28
228 SENSOR 19 ALARM REPORT CODE 0 - 99 29
229 SENSOR 20 ALARM REPORT CODE 0 - 99 30
230 SENSOR 21 ALARM REPORT CODE 0 - 99 31
231 SENSOR 22 ALARM REPORT CODE 0 - 99 32
232 SENSOR 23 ALARM REPORT CODE 0 - 99 33
233 SENSOR 24 ALARM REPORT CODE 0 - 99 34
234 SENSOR 1 TROUBLE REPORT CODE 0 - 99 41
235 SENSOR 2 TROUBLE REPORT CODE 0 - 99 42
236 SENSOR 3 TROUBLE REPORT CODE 0 - 99 43
237 SENSOR 4 TROUBLE REPORT CODE 0 - 99 44
238 SENSOR 5 TROUBLE REPORT CODE 0 - 99 45
239 SENSOR 6 TROUBLE REPORT CODE 0 - 99 46
240 SENSOR 7 TROUBLE REPORT CODE 0 - 99 47
241 SENSOR 8 TROUBLE REPORT CODE 0 - 99 48
242 SENSOR 9 TROUBLE REPORT CODE 0 - 99 49
243 SENSOR 10 TROUBLE REPORT CODE 0 - 99 50
244 SENSOR 11 TROUBLE REPORT CODE 0 - 99 51
245 SENSOR 12 TROUBLE REPORT CODE 0 - 99 52
246 SENSOR 13 TROUBLE REPORT CODE 0 - 99 53
247 SENSOR 14 TROUBLE REPORT CODE 0 - 99 54
248 SENSOR 15 TROUBLE REPORT CODE 0 - 99 55
249 SENSOR 16 TROUBLE REPORT CODE 0 - 99 56
250 SENSOR 17 TROUBLE REPORT CODE 0 - 99 57
251 SENSOR 18 TROUBLE REPORT CODE 0 - 99 58
252 SENSOR 19 TROUBLE REPORT CODE 0 - 99 59
253 SENSOR 20 TROUBLE REPORT CODE 0 - 99 60
254 SENSOR 21 TROUBLE REPORT CODE 0 - 99 61
255 SENSOR 22 TROUBLE REPORT CODE 0 - 99 62
256 SENSOR 23 TROUBLE REPORT CODE 0 - 99 63
257 SENSOR 24 TROUBLE REPORT CODE 0 - 99 64
Point ID Reporting Codes Table

LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear Corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of all other warranties express or implied. For warranty service on Linear equipment return product, at sender’s expense to:
FCC TELEPHONE RULES AND REGULATIONS The FCC requires that this alarm dialer system not make more than 15 repetitive dialing attempts to a single telephone number. There are no limitations when the calls are made sequentially to two or more alternative numbers, or when these calls are spaced 10 minutes apart to a single number. The FCC Rules and Regulations do not specify the re-attempt period as this can vary for specific applications. When setting this period, take into consideration local, interstate, foreign and special network call completion characteristics, network processing time, a sufficient number of rings and busy/don’t answer modes .
FIRE EVACUATION PLANNING For systems that include fire protection, the following information should be available to the users of the system.
✶Draw up a floor plan showing two exits for each room.
Linear Hong Kong 19/F Hounor Industrial Centre 6 Sun Yip Street Chai Wan, Hong Kong Attention: Repairs Department
The following procedures are to be discussed with the family:
➀Status of bedroom doors. ➁Familiarity with alarm signals. ➂Testing of door during a fire and use of alternate escape route if door is
REPAIRS POLICY ✶Charges will be made for equipment that is not of warranty, shows
hot to touch. ➃Crawling and holding breath. ➄Escape fast. No stopping for packing. ➅Meet at designated outdoor spot. ➆Emphasize that no one is to return to a burning house. ➇Fire department notification from a neighbor’s phone. ➈Periodic rehearsal is to be conducted.
customer abuse, or is damaged by the effects of lightning, water, fire, or other abnormal happenings. ✶Customer’s equipment sent in for repair may be repaired or replaced with
new or remanufactured equipment at Linear’s discretion. ✶The customer is always responsible for shipping and handling charges to
the repairs facility. Linear will pay return shipping and handling charges on “in warranty” products shipped back to the customer. The customer will be billed for the return shipping and handling charges on “out of warranty” products. ✶There will be a 50% expedite fee for any express requests. ✶The International Sales Manager must be notified prior to the return of
INDUSTRY CANADA NOTICES NOTICE: The ringer equivalence number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the ringer equivalence numbers of all the devices does not exceed 5. NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
product to Linear. All international returns must have an International Repair Authorization number (IRA#). The number must be marked on all packages. Failure to do so will cause delays in processing.
✶The radios are required to comply with local rules and regulations as radio
devices. As such, they have limited transmitter power and therefore limited range. ✶A receiver cannot respond to more than one transmitted signal at a time
and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings. ✶Changes or modifications to the device may void regulatory compliance. ✶Infrequently used radio links should be tested regularly to protect against
undetected interference or fault. ✶A general knowledge of radio and its vagaries should be gained prior to
acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users
FCC NOTICE This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
✶Relocate the Console away from the TV/radio receiver. ✶Plug the Console into a different wall outlet so that the Console is on a
different branch circuit. ✶Re-orient the TV/radio antenna. ✶If necessary, the user should consult the dealer or an experienced
radio/television technician for additional suggestions.
Copyright © 2002 Linear Corporation 217157 B
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.