REMOTE ACCESS SOFTWARE

Reference Manual for Programming the DVS-1200, DVS-2400, DUAL-824 & DVS-2408 Supervised Wireless Security Systems
WRITER’S NOTE: This publication could contain technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Linear may make improvements and/or changes in the product(s) and/or software described in this publication at any time.
MS-DOS®, Windows™, WindowsNT™, Windows95™, Windows98™, WindowsME™, WindowsXP™ and Windows2000™, and are registered trademarks of Microsoft Corporation.
Pentium® is a registered trademark of Intel Corporation.
IBM® is a registered trademark of International Business Machines Corporation.



What is the RA-2400 Remote Access Software?
The RA-2400 Remote Access software is a communications program designed to work with Linear’s DVS Supervised Wireless Security Systems and other Linear products. The software runs on an IBM PC or compatible computer and connects to the console through the standard telephone network, or to the Console directly, with the computer’s modem. This 32-bit software runs under all Windows operating systems.
RA-2400 sets the options for: Console access codes, exit/entry delays, alarm, audio, and sensors; communicator telephone numbers, call routing, formats, reporting codes, account numbers, and other options.
The RA-2400 software has a large help fi le that can be accessed at any time by selecting “Contents” from the “Help” menu or by pressing the F1 key.
How does RA-2400 connect to a DVS Console?
Remote Access communicates with the Console over the same phone line the Console uses to send communicator reports. Remote Access can also connect to the Console without a telephone line by directly connecting the Computer modem’s LINE jack to the Console’s T & R Terminals using a telephone cord.
With a telephone line connection (remote connection), a special dialing procedure is used. First, Remote Access dials the phone number specifi ed for the Console. Remote Access waits long enough for the phone to ring two or three times, then hangs up. Next, Remote Access waits, then dials again. This second call is answered on the fi rst ring by the Console.
With a direct connection (local cable connection), Remote Access prompts the user to place the Console in Test Mode and press the Console’s EMERGENCY button to establish the connection.
Once the connection is made, the Console will check if its remote access password matches the calling software’s password. If the passwords match, access is granted.
Do I have to be connected to a Console to make programming changes?
Since Remote Access knows the programming structure, you can modify an Account Profi le without being connected to a Console. This means you can set all of the values for a specifi c Console confi guration and then connect to a unit and send all of the values that you have set. This is referred to as off-line Console confi guration.
How do I change Console settings while on-line?
While on-line with the Console, make any changes to the Account Profi le then send the data to change the Console.
Can I make a template with the typical settings for all of my accounts?
Programming “templates” can be created to speed up programming multiple Consoles. Common settings, such as the Central Station telephone number, communicator format, Console and communicator confi gurations which are shared by all of your accounts can be stored in an Account Profi le and used as a template. That template fi le can be used as a basis for creating each customer Account Profi le fi le. See “Using Profi le Copies” in the Help contents for more information on creating a template.
How do I add and remove the program’s password?
A password can be set to restrict the RA-2400 to authorized users only. To add a password, select “Change Password...” from the “Options” menu. Enter the password in the “New Password” fi eld. Verify it by entering the password again in “Re-type New Password” and click OK. To remove the password, enter your password in “Old Password”, don’t enter anything on the “New Password” and “Re-type New Password” fi elds and press OK.

IBM compatible 486 personal computer with 8 Mb RAM
Windows 95/98/NT/ME/XP/2000 operating systems
VGA monitor
Name brand modem that is capable of 300 baud (BELL 103
compatible)
Hard disk drive with 10 Mb available space for the software
plus 18K available space for each Account Profi le fi le.
Recommended System:
Pentium or better based personal computer with 16 Mb RAM
or more
Windows 95/98/NT/ME/XP/2000 operating systems
SVGA video card
Microsoft compatible mouse
Name brand modem that is capable of 300 baud (BELL 103
compatible)
Large hard disk drive (1000 Account Profi les use about 20
Mb)
CD drive
Compatible Systems Note:
The software described in this manual supports the programming of a variety of models of Linear’s Wireless Security Systems. References in these instructions are focused on the Model DVS-2400. The programming differences for the other models supported by this software are: DVS-1200: This model is identical to the DVS-2400 with the limitation of supporting only 12 sensors. Only the fi rst 12 sensors can be programmed in Sections 4.9, 4.13.1, and 4.13.2. DVS-2408/DUAL-824: This model programs the same as the DVS-2400 with the addition of supporting 8 hardwired loops. Hardwired loop programming is described in Section 4.9. PERS-2400: This model is not a Security System, but a Personal Emergency Reporting System. Refer to the RA-2400/PERS-2400 Programming Reference Guide P/N: 217163 for details on programming this model.

Use the following programming outline to guide you through the steps required to set up the RA-2400 software and program a DVS-2400 Console. Many of the programming options available in the RA-2400 program can be left in their default settings, and do not need to be changed for most installations.
✦ Install the software on your computer (Section 1.4).
✦ Test your computer’s modem (Section 1.5).
✦ Start the RA-2400 program (Section 2.1).
✦ Set the Communications Setup options (Section 3).
✦ Open a new Account Profi le (Section 4.1).
✦ Enter customer information (Section 4.2).
✦ Set the Console’s access codes (Section 4.3).
✦ Set the Console’s arm/disarm options (Section 4.4).
✦ Set the Console’s exit/entry delays (Section 4.5).
✦ Set the Console’s alarm options (Section 4.6).
✦ Set the Console’s home-automation options (Section 4.7).
✦ Set the Console’s audio options (Section 4.8).
✦ Enable the Console’s communicator and choose a communicator
format (Section 4.10).
✦ Choose the communicator’s account number, telephone numbers,
and trouble report routing (Section 4.11).
✦ Set the communicator reporting options (Section 4.12).
✦ Set the communicator format reporting options (Section 4.13 or
4.14).
✦ Choose an Account Profi le (Section 5.2).
✦ Connect to the Console (Section 5.3).
✦ Send the data to the Console (Section 5.4).
✦ Receive the data from the Console (Section 5.5).
✦ Change the Console’s Mode (Section 5.6).
✦ Disconnect from the Console (Section 5.7).
AFTER ANY PROGRAMMING CHANGES ARE MADE TO A CONSOLE, PERFORM THOROUGH TESTING TO VERIFY THAT THE CONSOLE OPERATES AS INTENDED.

The RA-2400 Remote Access Program software is supplied on a CD- ROM. The installation program will create a directory on your hard disk drive. Be sure that you have at least 10 megabytes free on the hard disk for the program and any Account Profi le fi les that you create.
✦ The fi rst step is to close all other running programs.
✦ Place the Remote Access CD into your computer CD drive.
✦ The installation process should start automatically. If the CD does
not auto run, use Windows Explorer to fi nd RASETUP.EXE on the CD. Double-click on RASETUP.EXE and the install program will start.
✦ Click the Next button to install the Remote Access software.
Follow the on-screen instructions as the setup program creates the directory and copies the program fi les onto your hard disk. A Remote Access icon will be created on your desktop screen.
✦ If you are performing a reinstallation, or an update, you will be
prompted to uninstall RA-2400 fi rst. After the uninstall is completed, browse to the appropriate drive letter for your CD drive and double- click on RASETUP.EXE. Then follow the on-screen steps to install the Remote Access software.
☞ NOTE: If Windows asks whether to replace existing .DLL fi les, fi rst answer NO. If RA-2400 fails to run, re-install RA-2400 and answer YES to replace existing .DLL fi les.
✦ Remove the CD and store it in a safe place.
✦ Press START, SETTINGS, CONTROL PANEL. Double-click on
ADD/REMOVE PROGRAMS.
✦ Select Linear RA-2400 and click ADD/REMOVE or CHANGE/
REMOVE button depending on your Windows Operating system.


Before you run the Remote Access Program, be sure that the computer is running correctly and that the modem is installed and working properly.
Windows Control Panel can be used to test the modem and determine what COM port it is connected to.
✦ Press START, SETTINGS, CONTROL PANEL. Double-click on
MODEMS.
✦ Verify that a modem is shown in the Modem Properties window.
✦ Click on the DIAGNOSTICS tab. The modem installed with the
COM port highlighted should be shown.
✦ Note the COM port information. It is used when setting COM port in
the Communications Setup window (see Section 3.1).
✦ Test the modem by pressing the MORE INFO... button. IF THE
MODEM IS CONNECTED AND WORKING PROPERLY, THE “MORE INFO” WINDOW WILL DISPLAY DETAILED MODEM INFORMATION. If the modem is not working properly, Windows will notify you.

2.1 STARTING THE PROGRAM 7
2.2 NEW WINDOW 7
2.3 MENU BAR 8
2.4 ACCOUNT PROFILE WINDOW OVERVIEW 10
☞ NOTE: Experienced computer or PC users should fi nd that entering data and navigating around the RA-2400 program dialog boxes is similar to most other Windows programs. New users, or users unfamiliar with running Windows applications, should refer to the Windows help fi le for details on using Windows.


✦ Press START, point to PROGRAMS, RA2400 and click on RA2400.

To select an Account Profi le template for the type of unit being programmed.
✦ Select DVS-2400/2408 (with the correct Console fi rmware version
number).
✦ Press OK. The RA-2400 program window will appear with a starter template called DVS-2400/2408 Vx.x-1 showing in the workspace. This fi le can be stored later, under any name, using SAVE AS... in the FILE menu (see Section 2.3).


To provide access to each of the programs sub-menus.
The sub-menus that can be accessed from this menu are:
NEW
To select an Account Profi le template for the type of unit being programmed.
Loads a saved Account Profi le into the RA-2400 workspace. Mul- tiple Account Profi les can be open at the same time in the RA-2400 workspace. They can be arranged in the workspace using the Window menu on the menu bar, or by dragging them around manually.
Closes the active Account Profi le. If there were any changes to the fi le, Windows will ask if you want to save the changes.
Saves the active Account Profi le to the hard drive, overwriting the existing fi le.
SAVE AS...
Saves the active Account Profi le while giving the option to change the name or location of the fi le.
PRINT...
Opens the PRINT window to allow printing of the active Account Profi le. Resulting printout is the entire content of the Account Profi le fi le in text format.
Shows what will be printed on the screen with options to zoom in or print the document.
Shows the last four fi le names (with paths) that were opened in RA-2400. Clicking on a fi le opens it.
Closes the RA-2400 program. If any open Account Profi les have changed, Windows will ask if you want to save them.



To enter data and make changes to an Account Profi le and customize it for a specifi c installation.
MENU TREE Used for selecting the various data entry fi elds in the Account Profi le. Clicking on the plus (+) symbols expands the branches of the menu tree. Clicking on the minus (-) symbols collapses the menu tree branch. Clicking on an item displays the data entry fi elds in the edit area or other information.
EDIT AREA Used for adding and changing the data in the Account Profi le. Click on the check boxes, buttons, and enter text and numbers in the data areas to modify the Account Profi le.

3.1 COM PORT 12
3.2 SPEAKER 12
3.3 CONNECTION OPTIONS 13
3.4 MODEM INITIALIZATION STRING 14

The communications setup window sets the COM port for the modem, the modem’s speaker characteristics, type of connection (local or remote), dialing method (tone or pulse), and modem initialization string.
✦ From the COMMUNICATIONS menu, select SETUP... to view the
Communications Setup window.
✦ See Sections 3.1 - 3.4 and make any changes as required.
✦ After making any changes to the Communication Setup window,
click OK to accept the changes and close the window.


To select which communications (COM) port the modem is connected to.
✦ Click on the COM port number (1, 2, 3, or 4) that the modem is
connected to.
☞ NOTE: See the TESTING THE MODEM Section (1.5) of this manual for determining the proper COM port number.

To set how the modem’s speaker functions before and during communications.
✦ Select OFF to silence the modem’s speaker at all times.
✦ Select CARRIER to hear the modem connect and have the speaker
silenced when the RA-2400 is connected to the DVS-2400 Console.
✦ Select ON to hear the modem connect and hear the RA-2400
communicate with the DVS-2400 Console (for testing only).


To choose how the modem will connect to the DVS-2400 Console.
Remote Dialing dials a telephone number with the method chosen (tone or pulse) to connect with the Console over a standard telephone line.
Local Cable Connection does not dial a telephone number, but communicates with the Console wired directly to the modem.
✦ Select REMOTE DIALING if the Console is going to be accessed over
the telephone line.
✦ Select TONE or PULSE depending on the requirements for your
telephone system. NOTE: This only affects Remote Dialing.
✦ Select LOCAL CABLE CONNECTION if the Console’s T & R terminals
are connected directly to the modem’s LINE jack.
MODEM
MODEM'S LINE JACK TO CONSOLE'S T & R TERMINALS


Used to choose whether the default or a custom initialization “string” is sent to confi gure the modem (a “string” is a series of characters that are commands for the modem). Modem’s use initialization strings to setup their speed, data type, and other options. The RA-2400 sends the initialization string to the modem before using the modem to connect to the DVS-2400.
☞ NOTE: There are hundreds of models of modems available, each with unique characteristics. Instead of using the default modem string, some modems may perform better with a custom initialization string.
✦ Leave USE DEFAULT INITIALIZATION STRING option selected unless
you are having trouble connecting with your modem.
✦ IF YOU ARE HAVING TROUBLE CONNECTING WITH YOUR
MODEM, and it tests OK with the Windows modem test diagnostics (see Section 1.5), try using a custom initialization string. Various model modems have different requirements for initialization strings. Refer to your modem’s manual for the required commands to place the modem in 300 BAUD BELL 103 confi guration. Two examples are “&F1&N1” and “N0S37=1”. If the initalization string is incorrect, the RA-2400 will display “ERROR WRITING INITIALIZATION STRING”.
☞ NOTE: When entering a custom initialization string, don’t enter the “AT” command. The RA-2400 program will do this automatically.

4.1 NEW WINDOW 16
4.2 CUSTOMER INFORMATION 17
4.3 CONSOLE ACCESS CODES 18
4.4 CONSOLE ARM/DISARM 19
4.5 CONSOLE ENTRY/EXIT 20
4.6 CONSOLE ALARMS 21
4.7 CONSOLE HOME-AUTOMATION OUTPUT 22
4.8 CONSOLE AUDIO 23
4.9 SENSORS 24
4.10 COMMUNICATOR MAIN 26
4.11 COMMUNICATOR ROUTING AND NUMBERS 27
4.12 COMMUNICATOR ENABLED REPORTS 28
4.13 COMMUNICATOR 4 BY 2 FORMAT 29
4.13.1 4 BY 2 POINT-TO-POINT ALARM CODES 30
4.13.2 4 BY 2 POINT-TO-POINT TROUBLE CODES 31
4.13.3 4 BY 2 POINT-TO-POINT ARMING (CLOSING) CODES 32
4.13.4 4 BY 2 POINT-TO-POINT DISARMING (OPENING) CODES 33
4.13.5 CONSOLE ALARM CODES 34
4.13.6 4 BY 2 GENERAL ALARM CODES 35
4.14 ADEMCO CONTACT-ID REPORT CODES 36
Each installation requires an Account Profi le. While many items are the same in different Consoles reporting to the same Central Station, some items (account number, customer information, & sensor information) are unique for each installation.
A custom Account Profi le is created by editing the DVS-2400 Account Profi le template included with the RA-2400 software. The customized profi le should then be saved with a unique name for the account and then sent to the DVS-2400 Console.
To provide a clean start. Close any open Account Profi les on the workspace.

To select an Account Profi le template for the type of unit being programmed.
NEW ✦ Click on NEW icon on tool bar or select NEW from the FILE menu.
✦ Select DVS-2400/2408 (with the correct Console fi rmware version
number).
✦ Click OK. The new Account Profi le will appear as a starter template called DVS-2400/2408 Vx.x-1 (or -2, -3, etc.) in the workspace.


For entering customer information specifi c to the installation for the Account Profi le.
☞ NOTE: All fi elds are optional and do not have to be fi lled in. This information is not sent to the Console.
✦ Enter a CUSTOMER ID for the installation.
✦ Enter the customers name in the NAME fi eld.
✦ Enter the customers address in ADDRESS fi elds 1, 2, & 3.
✦ Enter the customers telephone number(s) in PHONE fi elds 1 & 2.
✦ Enter the number of the telephone line that the Console is
connected to in the CONSOLE PHONE fi eld. This fi eld will show as the telephone number for the account in the Send/Receive window.
☞ NOTE: DO NOT enter any dashes or spaces into the telephone number fi elds. Enter numbers only.
✦ Enter any special information about the customer in the NOTES fi eld.


To install a Master Access Code and up to 5 Restricted Access Codes, a Duress Code, and a Page Alert Code.
MASTER ACCESS CODE ✦ Allows arming and disarming the Console. Allows access to all programming
options.
RESTRICTED ACCESS CODE ✦ Allows arming and disarming the Console. Allows entering and editing
Restricted Access Codes.
DURESS ACCESS CODE ✦ Allows all options of a Restricted Access Code and causes the Console to
report the duress code to the Central Station if programmed to report.
PAGE ALERT CODE ✦ Allows all options of a Restricted Access Code and causes the Console
to dial the supervisory number (see Section 4.11, Communicator Routing and Numbers).
is “1234”. Enter any combination of 1 to 5 digits (3 to 5 digits recommended) for the Master Access Code.
recommended) for Restricted Access Codes 1-5.
for the Duress Code. The Duress Code should be 2 or more digits different than any other user code to help minimize accidental activation.
recommended) for the Page Alert Code.


To select which modes any remote arm/disarm transmitters will switch to. Also for selection of fi ve arm/disarm options.
remote arm/disarm transmitters will arm the Console to.
any remote arm/disarm transmitters will disarm the Console to.
control, if this box is checked the Console will “chirp” once when armed, twice when disarmed, and three times when arming with sensors bypassed. Un-check this box to silence the “chirps”.
any open sensors when the system is armed. If arming is attempted with open sensors, the Console will sound fi ve two-tone beeps and will not arm. Arming to the same mode again within fi ve seconds will bypass any open sensors and arm the Console. Check this box and the Console will automatically bypass any open sensors when the system is armed.
cannot cause an alarm. If this box is checked, the Console will automatically restore (remove the bypass from) any bypassed sensor when the sensor closes. After it’s restored, the sensor is ready to cause an alarm the next time it is opened. Un-check this box to not automatically restore sensors that close.
by holding down a mode key for two seconds. Un-check this box and an access code must be entered before pressing the mode buttons.
✦ HOME AUTOMATION OUTPUT ACTIVE WHILE ARMED: If this box is checked,
the Console’s Automation Output will activate when the system is armed. Un-check this box to disable this feature.


To select delay times and other options for the Console’s exit and entry delays.
20 to 255 seconds.
to 255 seconds.
during the entry delay. Un-check this box to silence the beeps during the entry delay.
during the exit delay. Un-check this box to silence the beeps during the exit delay.
✦ HOME-AUTOMATION OUTPUT ACTIVE DURING ENTRY/EXIT: With this box
checked, the home-automation output will be active during the entry/exit delay. Un-check this box to disable this feature.


For setting the way the burglary, emergency and fi re sirens work. Also sets the options for the home-automation output during and after alarms.
select SIREN FOR SET TIME for a timed siren after activation. With timed siren selected, enter the length of time (from 1 to 30 minutes) for the burglary siren to run.
or select SIREN FOR SET TIME for a timed siren after activation. With timed siren selected, enter the length of time (from 1 to 30 minutes) for the emergency siren to run.
fi re siren to run in the FIRE ALARM SIREN TIME area.
✦ HOME-AUTOMATION OUTPUT DURING SIREN TIME: Select NONE, FLASH,
or ACTIVE from the drop-down menu to choose the way the home-automation output functions while the siren is running.
✦ HOME-AUTOMATION OUTPUT FLASHES DURING/AFTER ALARM: With this
box checked, the home-automation output will fl ash during and after an alarm until the Console is disarmed.
☞ NOTE: The home-automation output will activate steady if the above option is set to ACTIVE.


For setting the way the home-automation output functions.
output to switch between on & off with each activation. Select ACTIVE FOR SET DURATION for a timed home-automation output and enter the length of time 1-2500 (in seconds) for the output to activate.
terminal fl oat when the output is active. Select SHORTED TO COMMON to have the home-automation minus terminal switch to common ground when the output is active.
will sound a “bing” when the home-automation output is activated. Un-check this box to have the home-automation output activate silently.


To select how the Voice Board operates. NOTE: The Model VB-2 (for 2-way audio) or VB-3 Voice Board must be installed to use these options. Selects the audio mode for monitoring with the Console’s microphone and communicating through the Console’s speaker to the subscriber. Controls the human voice prompts from the Voice Board.
With 2-way Audio enabled, after the Central Station operator acknowledges the communicators report, the Console will stop its siren and switch to the selected audio mode for 90 seconds.
AUDIO ✦ Click the arrow to show a list of settings for Two-way Audio and
select the desired mode. NONE: Audio Board will not report as an audio account to the Central Station. No audio monitoring will occur. LISTEN-ONLY: The operator will be able to hear sound from the Console but will not be able to talk through the Console’s speaker. Pressing “9” on a telephone connected to the line disconnects the call (press any key but “9” to extend the time 90 seconds). TWO-WAY MANUAL: The operator will be able to hear sound from the Console and will be able to talk through the Console’s speaker. The operator can switch from listen to talk by pressing “1”, or switch from talk to listen by pressing “3” on a telephone connected to the line. Pressing “9” disconnects the call (press any key but “9” to extend the time 90 seconds). TWO-WAY DUPLEX: The operator will be able to hear sound from the Console and will be able to talk through the Console’s speaker. The audio board will listen until the operator speaks, then the voice activation will switch the voice board to talk as long as the operator speaks. The operator can still switch from listen to talk manually by pressing “1”, or switch from talk to listen by pressing “3” on a telephone connected to the line (with increased volume). Pressing “8” returns to two-way duplex. Pressing “9” disconnects the call. Press any key but “9” to extend the time 90 seconds.
✦ Check the VOICE PROMPTS ENABLED box to have the Console
announce system events with a digitally synthesized human voice.


To display and edit sensors installed in the Console’s memory. Up to 24 sensors may be installed, each with its own type, restore and supervision options. The status of the sensor selected is also displayed.
☞ NOTE: To display and edit sensors installed in the Console, the sensor data must fi rst be received from the Console (see Section 5.5).
SENSOR TYPE ✦ Click on the sensor in the menu tree to view it.
✦ View or edit the SENSOR TYPE. The sensor type options are:
NOT INSTALLED: No sensor has been stored in this sensor location. Also can be used to remove a sensor from the Console’s memory. Sensors cannot be added with this menu. HOME AUTOMATION: Sensor will trigger the Console’s home-automation output. EMERGENCY: Sensor will trigger the emergency siren and report the emergency code to the Central Station. POLICE: Sensor will trigger the silent panic alarm and report the police code to the Central Station. FIRE: Sensor will trigger the fi re siren and report the fi re code to the Central Station.

PERIMETER: Sensor will instantly trigger the burglary siren and report the burglary code to the Central Station in Home or Away Mode. Sensor will sound chime in Chime Mode. ENTRY/EXIT: Sensor uses the exit/entry delay and can trigger the burglary siren and report the burglary code to the Central Station in Home or Away mode. Sensor will sound chime in Chime Mode. INTERIOR: Sensor is only active in the Away Mode. It will instantly trigger the burglary siren and report the burglary code to the Central Station if triggered before an entry/exit sensor. Causes a delayed alarm if activated during the entry delay. CHIME: Sensor will sound chime in all modes. ARM/DISARM + HOME AUTO: The left button on a 2-button sensor will arm/disarm the Console. The right button on a 2-button sensor activates the home-automation output. Pressing both buttons triggers the emergency siren. ARM & DISARM: The left button on a 2-button sensor will arm the Console. The right button on a 2-button sensor will disarm the Console. Pressing both buttons triggers the emergency siren. ENVIRONMENTAL: Sensor is always armed in all modes. Causes a local annunciation when triggered. KEYPAD: Reserved for wireless keypads used with the Console. INTERIOR HOME: Sensor allows interior zones to trigger an alarm. This will generally be used with PIRs that are not in normal nighttime mode.
SENSOR OPTIONS ✦ View or edit the SENSOR OPTIONS. These options are automatically set when
the sensor is programmed into the Console. The sensor options are: AUTO RESTORE: This box should be checked for auto restoring sensors that only send alarm transmissions. The Console will automatically restore the “open” sensor. SUPERVISED: This box should be checked for all sensors that send periodic status reports. DXT sensors do not send periodic status reports. REMOVE THE CHECK FROM THIS BOX IF A MODEL DXT SENSOR HAS BEEN PROGRAMMED INTO THIS SENSOR LOCATION or if you don’t want supervision for that sensor. This will keep the Console TROUBLE indicator from lighting due to missing status reports from that sensor.
☞ NOTE: The sensor can still report a low battery condition this will cause the Console’s BATTERIES indicator to fl ash. HARDWIRED OPTIONS: For Model DVS-2408 only. Selects which hardwired loop (1-8) is assigned to the sensor number selected. For non-hardwired sensors, this selection should be set to WIRELESS.
SENSOR STATUS ✦ View the SENSOR STATUS to see the condition of the sensor selected.
The sensor status conditions are: BYPASSED: The Console was armed with this sensor open. It is currently bypassed and cannot cause an alarm. LOW BATTERY: The sensor has sent a low battery signal to the Console. Replace the sensor’s battery. TROUBLE: The Console has not received a status report from this sensor in 8 hours. Sensor may have been out of range of the Console’s receiver, or the sensor may be non-functional.
☞ NOTE: After any changes are made to the sensor type or sensor options, test the sensor to verify proper operation. Testing the “repaired” transmitter will reset the TROUBLE indicator.


For confi guring the Console’s communicator format, dialing method, remote access password, dialing delay, and auto answer options.
COMMUNICATOR MAIN ✦ Check the ON box to enable the communicator in the Console.
☞ NOTE: You may want to turn the communicator off while testing the system to prevent the Console from trying to dial out when it is not connected to a telephone line.
format depending on the Central Station’s requirements.
✦ DIAL METHOD: Select either TONE or PULSE dialing for the Console.
required to connect to the Console with the RA-2400 program. The default password is “987654”. DO NOT FORGET THIS PASSWORD, LOCAL OR REMOTE PROGRAMMING ACCESS TO THE DVS-2400 IS IMPOSSIBLE WITHOUT IT.
the communicator starts to dial after an alarm. This gives the subscriber time to cancel a Central Station report before the unit dials out.
Station burglary reports to fi ve per arming period. This will not effect the 24-hour zones (fi re, panic, and emergency).
detection feature. This keeps the Console from automatically answering the phone. Even if this box is checked, the Console can still be programmed by placing the Console into Test Mode and forcing the Console to answer by pressing the EMERGENCY button while the phone is ringing.


For confi guring the Console’s communicator account number, trouble report routing, and telephone numbers.
ACCOUNT NUMBERS ✦ Enter a four digit account number for the communicator format used.
TROUBLE REPORT ROUTING ✦ Select TROUBLE REPORTS TO PRIMARY AND SECONDARY to have trouble
reports routed to the primary number for fi ve attempts, then to the secondary number for fi ve attempts before re-trying. Select TROUBLE REPORTS ONLY TO SUPERVISORY to have trouble reports routed to the supervisory number only (don’t select this option if the page alert feature is being used).
☞ NOTE: This does not effect emergency reports which are always routed to the primary or secondary telephone numbers.
PHONE NUMBERS Telephone numbers can be up to 20 digits long. DO NOT enter any dashes or spaces into the telephone number fi elds. The “#” symbol inserts a 1-second delay, the “~” symbol inserts a 5-second delay.
☞ NOTE: If no telephone numbers are entered, the Console will not report.
receiver.
Central Station receiver.
to connect the Central Station receiver for supervisory reports. For Page Alert: Enter the pager telephone number and the numerical message (up to 20 digits total) into the SUPERVISORY area. TIP: Call the pager number and measure the time between placing the call and the prompt to key-in the pager message. Use this time measurement to choose the special characters (# or ~) to insert a delay between the pager telephone number and pager message. NOTE: Many pager companies require a pound sign (#) to end the message (a pound sign at the end of the page alert message is treated as the # key, not is a delay) Example with a 7-second delay and pound sign end: 5551234~##07734#


For confi guring the Console condition reporting options.
arming of the Console to Away Mode with an open and bypassed sensor.
battery and Console backup battery restoral (charged after being low) conditions.
and close (arming) reporting:
DISABLED: Select this option for no open/close reports.
ENABLED: Select this option for open/close reports when the system is armed or disarmed by any user’s access code.
MASTER ONLY: Select this option for open/close reports only when the system is armed or disarmed using the master access code.
ACCESS CODE 4 BY 2 CLOSING (ARMING) CODE
4 BY 2 OPENING (DISARMING) CODE
MASTER ACCESS CODE 74 82 RESTRICTED ACCESS CODE #1 75 83 RESTRICTED ACCESS CODE #2 76 84 RESTRICTED ACCESS CODE #3 77 85 RESTRICTED ACCESS CODE #4 78 86 RESTRICTED ACCESS CODE #5 79 87 REMOTE/HARDWIRE ARM & QUICK ARM 81 89


☞ NOTE: Section 4.13 pertains to the 4 by 2 communicator format only.
For confi guring how the 4 by 2 format will report to the Central Station. General reporting or Point-to-Point reporting methods are available for the 4 by 2 format.
GENERAL REPORTING: General reporting can send fi ve report codes for sensors: FIRE, EMERGENCY, POLICE, BURGLARY and TROUBLE. General reporting does not indicate which sensor caused the report.
POINT-TO-POINT REPORTING: Point-to-Point reporting sends each sensor/ zone number with a unique ALARM code and TROUBLE code.
☞ NOTE: With either reporting method, the Console alarm codes are the same (see Section 4.13.5).
4 BY 2 FORMAT ✦ Select POINT-TO-POINT to have the Console’s communicator send
4 by 2 Point-to-Point report codes. Select GENERAL to have the Console’s communicator send only the fi ve 4 by 2 General report codes.


To view and edit the 24 sensor/zone alarm report codes.
☞ NOTE: 4 by 2 Point-to-Point Reporting must be selected (see Section 4.13) for these codes to report.
ZONE CODES ✦ Enter a new two-digit alarm code for any sensor/zone that needs
to be changed.
☞ NOTE: Entering a “0” for an alarm code will prevent that zone from reporting.


To view and edit the 24 sensor/zone trouble report codes.
☞ NOTE: 4 by 2 Point-to-Point Reporting must be selected (see Section 4.13) for these codes to report.
ZONE CODES ✦ Enter a new two-digit trouble code for any sensor/zone that needs
to be changed.
☞ NOTE: Entering a “0” for a trouble code will prevent that zone from reporting.


To view and edit the force arming report code. This report is sent when force arm is enabled (Section 4.12) and the system is armed with any open sensors that have been bypassed.
☞ NOTE: With either reporting method, the force arming code is the same.
be changed.
☞ NOTE: Entering a “0” for a force arming code will prevent it from reporting.


To view and edit the duress report code. This report is sent when the system is armed or disarmed using the duress access code.
☞ NOTE: With either reporting method, the duress code is the same.
changed.
☞ NOTE: Entering a “0” for a duress code will prevent it from reporting.


To view and edit the fi ve Console report codes. These codes are sent for Console events such as the Console emergency button, fi re button, Console low battery and battery restore. The cancel report occurs when the Console is disarmed during an alarm.
☞ NOTE: These report codes are sent for both 4 by 2 General and 4 by 2 Point-to-Point Reporting.
CONSOLE ALARM CODES ✦ Enter a new two-digit report code for any Console event that needs
to be changed.
☞ NOTE: Entering a “0” for a report code will prevent that event from reporting.


To view and edit the four general alarm codes and the general trouble code.
☞ NOTE: 4 by 2 General Reporting must be selected (see Section 4.13) for these codes to report.
4 BY 2 GENERAL ALARM CODES ✦ Enter a new one or two-digit report code for any general alarm code
that needs to be changed.
☞ NOTE: Entering a “0” for an alarm code will prevent that event from reporting.

The Ademco Contact-ID reporting codes are pre-defi ned and cannot be changed. These reporting codes are provided as reference. The Ademco Contact-ID extended report codes indicate the sensor number that triggered the event. Console events report with a “000” extended code.
☞ NOTE: Ademco Contact-ID Reporting must be selected for these codes to report (see Section 4.10).
S E D O C T R O P E R D I-T C A T N O C O C M E D A S E D O C T R O P E R D I-T C A T N O C O C M E D A S E D O C T R O P E R D I-T C A T N O C O C M E D A S E D O C T R O P E R D I-T C A T N O C O C M E D A S E D O C T R O P E R D I-T C A T N O C O C M E D A
T N E V E T N E V E T N E V E T N E V E T N E V E E D O C M R A L A E D O C M R A L A E D O C M R A L A E D O C M R A L A E D O C M R A L A E D O C D E D N E T X E E D O C D E D N E T X E E D O C D E D N E T X E E D O C D E D N E T X E E D O C D E D N E T X E
Y C N E G R E M E R O S N E S 0 2 1 E x x 0 C
Y C N E G R E M E E L O S N O C 0 2 1 E 6 2 0 C
E R IF R O S N E S 1 1 1 E x x 0 C
E R IF E L O S N O C 0 1 1 E 5 2 0 C
M R A L A Y R A L G R U B 0 3 1 E x x 0 C
C I N A P T N E LIS 2 2 1 E x x 0 C
M R A E C R O F 4 7 5 E 0 0 0 C
S S E R U D 1 2 1 E 0 0 0 C
L E C N A C 6 0 4 E 0 0 0 C
Y R E T T A B W O L R O S N E S 4 8 3 E x x 0 C
E L B U O R T S U T A T S R O S N E S 1 8 3 E x x 0 C
Y R E T T A B W O L E L O S N O C 2 0 3 E 0 0 0 C
E R O T S E R Y R E T T A B E L O S N O C 2 0 3 R 0 0 0 C
O I D U A Y A W -2 6 0 6 E 0 0 0 C
T R O P E R D E D N E T X E N I R E B M U N R O S N E S = x x
S E D O C T R O P E R G N I S O L C & G N I N E P O D I-T C A T N O C O C M E D A S E D O C T R O P E R G N I S O L C & G N I N E P O D I-T C A T N O C O C M E D A S E D O C T R O P E R G N I S O L C & G N I N E P O D I-T C A T N O C O C M E D A S E D O C T R O P E R G N I S O L C & G N I N E P O D I-T C A T N O C O C M E D A S E D O C T R O P E R G N I S O L C & G N I N E P O D I-T C A T N O C O C M E D A
E D O C S S E C C A E D O C S S E C C A E D O C S S E C C A E D O C S S E C C A E D O C S S E C C A G N I S O L C O C M E D A G N I S O L C O C M E D A G N I S O L C O C M E D A G N I S O L C O C M E D A G N I S O L C O C M E D A
G N I N E P O O C M E D A G N I N E P O O C M E D A G N I N E P O O C M E D A G N I N E P O O C M E D A G N I N E P O O C M E D A
E D O C ) G N I M R A ( E D O C ) G N I M R A ( E D O C ) G N I M R A ( E D O C ) G N I M R A ( E D O C ) G N I M R A (
E D O C ) G N I M R A S I D ( E D O C ) G N I M R A S I D ( E D O C ) G N I M R A S I D ( E D O C ) G N I M R A S I D ( E D O C ) G N I M R A S I D (
E D O C S S E C C A R E T S A M 0 0 0 C 1 0 4 R 0 0 0 C 1 0 4 E
1 # E D O C S S E C C A D E T C I R T S E R 1 0 0 C 1 0 4 R 1 0 0 C 1 0 4 E
2 # E D O C S S E C C A D E T C I R T S E R 2 0 0 C 1 0 4 R 2 0 0 C 1 0 4 E
3 # E D O C S S E C C A D E T C I R T S E R 3 0 0 C 1 0 4 R 3 0 0 C 1 0 4 E
4 # E D O C S S E C C A D E T C I R T S E R 4 0 0 C 1 0 4 R 4 0 0 C 1 0 4 E
5 # E D O C S S E C C A D E T C I R T S E R 5 0 0 C 1 0 4 R 5 0 0 C 1 0 4 E
M R A K C I U Q & M R A E R I W D R A H /E T O M E R 7 0 0 C 7 0 4 R
M R A SI D E R I W D R A H /E T O M E R 7 0 0 C 7 0 4 E

5.1 ACCESSING THE SEND/RECEIVE WINDOW 38
5.2 CHOOSING AN ACCOUNT PROFILE 39
5.3 CONNECTING TO A CONSOLE 40
5.4 SENDING DATA 42
5.5 RECEIVING DATA 43
5.6 CHANGING THE CONSOLE’S MODE 44
5.7 DISCONNECTING FROM THE CONSOLE 45
5.8 CLOSING RA-2400 46 Sending and receiving the Account Profi le data to the DVS-2400 Console is the main purpose of the RA-2400 program. The Account Profi les that you create exist only on your disk drive until they are copied to a Console. The Send/Receive window controls all external communications for the RA-2400 software. It is used to select which Account Profi le gets sent to, or received from, a Console in the fi eld (accessed through remote dialing) or connected directly to the modem (accessed through a local cable connection). See Section 3.3 for connection details.


CLICK THE SEND/RECEIVE BUTTON
For entering data required to connect to a DVS-2400 Console and to control the connection. Monitors the status of the communication between the RA-2400 and the DVS-2400.
✦ An Account Profi le fi le must be open before the Send/Receive
window can be accessed. Use the OPEN... or NEW command in the FILE menu or on the tool bar to load an Account Profi le into the workspace.
✦ From the COMMUNICATIONS menu, choose SEND/RECEIVE..., or click
on the SEND/RECEIVE button on the tool bar.


For selecting which Account Profi le open in the workspace will be used when connecting to a Console. The Account Profi le selected automatically fi lls in the Console’s Phone Number and Password Fields using information already entered in the profi le (see Section 2.4).
CHOOSE AN ACCOUNT ✦ Click on the desired Account Profi le in the Choose an Account box
for the Console that is going to be programmed. The installation telephone number and Console password should appear in the boxes.


Causes the RA-2400 to connect to the DVS-2400 Console. The RA-2400 will try to connect to the Console either locally or remotely, depending on the Communications Setup (see Section 3.3).
☞ NOTE: The Communications Setup can be reviewed by pressing the COMM SETUP... button in the Send/Receive window.
☞ NOTE: Before connecting to a Console, it is recommended that all of the sensors used in the system be entered into the Console’s memory. This will prevent having to connect to the Console again after programming if modifi cation of the sensor options is required.
BEFORE CONNECTING ✦ Be sure the computer’s modem is powered on, connected, and
tested as described in Section 1.5 of this manual.
✦ Check that the Console is powered on.
✦ Be sure that the Account Profi le you want to associate with the
particular Console is selected in the Choose an Account box.

CONNECTING LOCALLY ✦ Verify that the modem’s LINE jack is connected to the Console’s
T&R Terminals with a cable.
✦ Verify that the Console is in Test Mode.
✦ Click the CONNECT button. The Communication Status area will show
the progress of the connection. WAIT UNTIL THE TIMEOUT TIMER BEGINS TO COUNT DOWN BEFORE PROCEEDING.
✦ As the timeout timer counts down, PRESS THE EMERGENCY
BUTTON ON THE CONSOLE.
CONNECTING REMOTELY ✦ Be sure that the modem’s LINE jack is connected to a working
telephone line.
✦ Verify that the Console’s T&R Terminals are connected to a working
telephone line.
✦ Click the CONNECT button. The Communications Status area will show
the progress of the connection. WAIT FOR THE CONNECTION TO COMPLETE. The RA-2400 will dial the number once, wait for a few rings, hang-up, then dial a second time. The Console should answer the telephone immediately when the telephone rings during the second dialing attempt. After connecting the Communications Status area will show the progress of the on-line connection, then display “Connected” and the DVS-2400 version number.
The Console Power area will show the status of the Console’s AC power and backup battery. The Arming Mode area will show the Console’s current mode. Pressing the REFRESH button will update the displayed information.
Local Connection in Progress Remote Connection in Progress




For transferring data from an Account Profi le to a DVS-2400 Console.
☞ CAUTION: Receiving the data from the Console will overwrite the data in the Account Profi le. If you have made changes to the Account Profi le, save the profi le, then send the profi le to the Console before receiving the data into the profi le. This leaves previously learned sensor information unchanged. If this is a new Account Profi le, its OK to receive the Console data into the new profi le.
SENDING ✦ Click the SEND DATA TO CONSOLE button. The Communications Status
area will indicate the progress and show if the data was sent to the Console successfully.
You can make changes to the Account Profi le while the Console is connected. Be sure to send any changes to the Console before disconnecting. Minimize the Send/Receive window or slide it out of the way before editing the Account Profi le. There is a time limit to the connection. The Console will automatically disconnect after three minutes of inactivity.


For transferring data from a DVS-2400 Console to an Account Profi le.
☞ CAUTION: Receiving the data from the Console will overwrite the data in the Account Profi le.
RECEIVING ✦ Click the RECEIVE DATA FROM CONSOLE button. The Communications
Status area will indicate the progress and show if the data was received from the Console successfully.

To remotely view and change the operating mode of the Console.
ARMING MODE ✦ View the current operating mode of the Console in the ARMING
MODE display area.
✦ To change the current operating mode of the Console, select the
desired mode button (OFF, CHIME, HOME, or AWAY) in the ARMING MODE display area.
☞ NOTE: Test Mode and Learn Mode can only be selected directly from the Console’s keypad.

To end the programming session and disconnect the modem from the Console.
DISCONNECTING ✦ When fi nished communicating with the Console, click on the
DISCONNECT button. The Communications Status area will show Not Connected when the Console has been disconnected.


To save the active Account Profi le(s) and quit the RA-2400 program.
✦ From the FILE menu, choose EXIT.
✦ To save while exiting, in the SAVE CHANGES? window click YES.
If the active Account Profi le is the default template, select a location and new name for the fi le and click SAVE. If the active Account Profi le already has a custom fi le name, it will be saved with the same name.
☞ NOTE: If more than one Account Profi le template is open and has been changed, additional SAVE CHANGES? windows will appear.
AFTER ANY PROGRAMMING CHANGES ARE MADE TO A CONSOLE, PERFORM THROUGH TESTING TO VERIFY THAT THE CONSOLE OPERATES AS INTENDED.
Copyright © 2002 Linear Corporation 217473 C