EN
GarrettCom logo
Official user manual

GarrettCom MNS-6K

329 pages·4 MB·Switch·PDF·ENDEFRITNLJA
GarrettCom MNS-6K
Table of Contents 45 sections MNS-6K Software Updates · Operator Privileges · Manager Privileges · Add User · … ShowHide
Page 1 of the GarrettCom MNS-6K user manual — Release 3.7.1
Page 1 · click to enlarge
Page 1
GarrettCom MNS-6K diagram (page 1)
Fig. 1

MAGNUM 6K FAMILY OF SWITCHES

Managed Network Software (MNS) for Magnum 6K family of Switches

– MNS-6K

GarrettCom MNS-6K — Managed Network Software (MNS) for Magnum 6K family of Switches diagram (page 1)
Fig. 2 · Managed Network Software (MNS) for Magnum 6K family…

Release 3.7.1

CLI User Guide

Page 2 of the GarrettCom MNS-6K user manual — Preface
Page 2 · click to enlarge
Page 2

Preface

This guide describes how to use the Command Line Interface (CLI) for the Magnum 6K family of switches. For the Web Management Interface please refer to the Web Management Guide.

Some simple guidelines which will be useful for configuring and using the Magnum 6K family of switches -

ƒ If you need information on a specific command in the CLI, type the

command name after you type the word “help” (help ) or just type [Enter].

ƒ If you need information on a specific feature in Web Management Interface,

use the online help provided in the interface.

ƒ If you need further information or data sheets on GarrettCom Magnum 6K

family of switches, refer to the GarrettCom web links at:

http://www.garrettcom.com/managed_switches.htm (except MP62 switch shown on the page)

GarrettCom Inc. 47823 Westinghouse Drive Fremont, CA 94539-7437 Phone (510) 438-9071• Fax (510) 438-9072 Email – Tech support – support@garrettcom.com

Email – Sales – sales@garrettcom.com WWW – http://www.garrettcom.com/

Page 3 of the GarrettCom MNS-6K user manual — PK-040207
Page 3 · click to enlarge
Page 3

Trademarks

GarrettCom Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice. GarrettCom, Magnum, S-Ring, Link-Loss-Learn, Converter Switch, Convenient Switch and Personal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.

NEBS is a registered trademark of Telcordia Technologies.

UL is a registered trademark of Underwriters Laboratories.

Ethernet is a trademark of Xerox Corporation.

Copyright © 2007 GarrettCom, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from GarrettCom, Inc.

Printed in the United States of America.

Part #84-00131

PK-040207

Page 11 of the GarrettCom MNS-6K user manual — Updating boot code over the network................................319
Page 11 · click to enlarge
Page 11

Updating boot code over the network 319

Index................................................................................... 321

Page 19 of the GarrettCom MNS-6K user manual — Conventions followed in the manual…
Page 19 · click to enlarge
Page 19

Chapter 1

1 – Conventions Followed

Conventions followed in the manual…

T

o best use this document, please review some of the conventions followed in the manual, including screen captures, interactions and commands with the switch, etc.

Box shows interaction with the switch command line or screen captures from the switch or computer for clarity Commands typed by a user will be shown in a different color and this font Switch prompt – shown in Bold font, with a “# or >” at the end. For the document we will use Magnum6K25# as the default prompt. Syntax rules Optional entries are shown in [square brackets] Parameter values within are shown in < pointed brackets > Optional parameter values are shown again in [square brackets] Thus Syntax command [parameter1=<value1>[, parameter2=<value2>]] parameter3=<value3|value4> In the example above: Parameter 1 and Parameter 2 are optional values Parameter 2 can be used optionally only if Parameter 1 is specified Parameter 3 is mandatory. Parameter 1 has value1 = IP address Parameter 2 has value2 = string Parameter 3 has value3 or value4

Page 20 of the GarrettCom MNS-6K user manual — Flow of the User Guide
Page 20 · click to enlarge
Page 20

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Related Topics Related topics show that GarrettCom strongly recommends reading about those topics. You may choose to skip those if you already have prior detailed knowledge on those subjects. j

Tool box – Necessary software and hardware components needed (or recommended to have) as a prerequisite. These include serial ports on a computer, serial cables, TFTP or FTP software, serial terminal emulation software etc.

Terminology – Whenever the word PC is used it implies a UNIX, Linux, Windows or any other operating system based work station, computer, personal computer, laptop, notebook or any other computing device. Most of the manual uses Windows-XP based examples. While effort has been made to indicate other Operating System interactions, it is best to use a Windows-XP based machine when in doubt.

Supported MNS-6K Version – The documentation reflects features of MNS-6K version 3.4 or later. If your switch is not at the current version, GarrettCom Inc. recommends upgrade to the latest version. Please refer to the GarrettCom Web site for information on upgrading the MNS-6K software on Magnum 6K family of switches.

Product Family – this manual is for all the Magnum 6K family of switches.

Finally, at the end of each chapter, is a list of the commands covered in the chapter as well as a brief synopsis of what they do.

Flow of the User Guide

The manual is designed to guide the user through a sequence of events. Chapter 1 – this chapter Chapter 2 is the basic setup as required by the Magnum 6K family of switches. After completing Chapter 2, the configuration can be done using the web interface. Chapter 2 is perhaps the most critical chapter in what needs to be done by the network administrator once the switch is received.

Page 21 of the GarrettCom MNS-6K user manual
Page 21 · click to enlarge
Page 21

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Chapter 3 focuses on operational issues of the switch. This includes time synchronization using the command line or using a time server on the network. Chapter 4 through Chapter 6 focuses on security and access consideration. Bad passwords trump any security setup, so setup the manager passwords carefully as described in Chapter 2. Chapter 4 describes how to setup port access using MAC address security. Chapter 5 describes how a RADIUS server can be used for authentication and access. Chapter 6 essentially is similar to Chapter 5, and talks about using a TACACS+ server instead of a RADIUS server. Chapter 7 talks about port mirroring and preventing broadcast storms. Port mirroring is necessary in a network to reflect traffic from one port onto another port so that the traffic can be captured for protocol analysis or intrusion analysis. Chapter 8 deals with VLANs. VLANs provide security as well as traffic separation. This chapter shows how VLANs can be setup and managed. At this stage the network and the switch are secured. It is now critical to make the network more reliable. The User Guide switches gears and talks about STP, RSTP and S- Ring technologies which can be used for making the network reliable. These technologies allow resiliency in a network. Chapters 9 through Chapter 12 discuss some resiliency techniques. Chapter 9 shows how STP can be setup and used. Today, RSTP is preferred over STP. Chapter 10 shows how RSTP is setup and used as well as how RSTP can be used with legacy devices which support STP only. Chapter 11 focuses on S-Ring™ and setup of S-Ring (optional). This chapter also talks about using RS-Ring™ with managed switches. Chapter 12 talks about dual homing and how dual homing can be used to bring resiliency to edge devices. Chapter 13 describes LACP and how LACP can be used to increase the throughput using 10/100 Mbps ports or in situations where resiliency is needed between switches (trunks). Once the network is made resilient, the network manager may want to setup prioritization of traffic. Chapter 14 focuses on Quality of Service (QoS) and other prioritization issues. Chapters 15 and 16 focus on advanced topics such as IGMP and GVRP.

Page 22 of the GarrettCom MNS-6K user manual
Page 22 · click to enlarge
Page 22

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Chapter 15 focuses on IGMP. Chapter 16 focuses on GVRP. Chapter 17 shows how the SNMP parameters can be setup for managing the switch with network management software such as Castle Rock SNMPc™ Chapter 18 includes miscellaneous commands to improve the overall ease of use and other diagnostic information.

Page 23 of the GarrettCom MNS-6K user manual — Before starting
Page 23 · click to enlarge
Page 23

Chapter 2

2 – Getting Started

First few simple steps …

his section explains how the GarrettCom Magnum 6K family of switches can be setup using the console port on the switch. Some of the functionality includes setting up the IP address of the switch, securing the switch with a user name and password, setting up VLAN’s and more. T

Before starting

Before you start, it is recommended to acquire the hardware listed below and be ready with the items listed.

For initial configuration through the serial/console port 1) A female-female null modem cable. This cable is available from GarrettCom Inc. as well as from LAN store (http://www.lanstore.com) 2) Serial port – if your PC does not have a serial port, you may want to invest in a USB to serial converter. This is again available from LAN store or from GarrettCom Inc. Alternately a USB to serial cable can also be used. This cable is also available from LAN store or GarrettCom Inc. 3) A PC (or a workstation/computer) with a terminal emulation program such as HyperTerminal (included with Windows) or Teraterm-pro, minicom or other equivalent software. (Make sure the software supports Xmodem protocol, as you may need this in the future to update the MNS-6K software) 4) Enough disk space to store and retrieve the configuration files as well as copy software files from GarrettCom. We recommend at least 15MB of disk space for this purpose 5) Decide on a manager level account name and password for access security 6) IP address, netmask, default gateway for the switch being configured As a default, the switch has no IP (Internet Protocol) address and subnet mask. For first time use, the IP address has to be assigned. This can only be done by using the console interface provided.

Page 24 of the GarrettCom MNS-6K user manual — Console connection
Page 24 · click to enlarge
Page 24

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

The same procedure can also be used for other configuration changes or updates – e.g. changing the IP address, VLAN assignments and more. Once the IP address is assigned and a PC is networked to the switch, the switch’s command line interface (CLI) can be accessed via telnet. To manage the switch through in-band (networked) access (e.g. telnet, or Web Browser Interface), you should configure the switch with an IP address and subnet mask compatible with your network. You should also change the manager password to control access privileges from the console.

Many other features such as optimizing the switch’s performance, traffic engineering and traffic prioritizing, VLAN configuration, and improving network security can be configured through the switch’s console interface as well as in-band (networked) access, once the IP address is setup. Besides the IP address, setting up the SNMP parameters allows configuration and monitoring through an SNMP network management station running a network management program (e.g. SNMPc from Castle Rock – available from GarrettCom Inc.)

j

Magnum switches already have the necessary software loaded on them. If a software upgrade is needed or the MNS-6K software needs to be updated to the current version, please refer to the GarrettCom web site for information on updating the MNS-6K software. The documentation on how to update the MNS-6K is included as an Appendix in this manual.

The Login prompt is shown when the connection to the GarrettCom Magnum 6K Switch is successful and the switch is ready for the configuration commands. Should you get a boot prompt, please contact GarrettCom technical support. The IP address of the switch is assigned automatically from a DHCP server or a BootP server. If these servers do not exist, the switch will be assigned an IP address which was previously configured or a static IP address of 192.168.1.2 with a netmask of 255.255.255.0 (if that address is not in use). It is recommended that the user uses Secure Web Management (SWM) capabilities built into MNS-6K to setup and manage the switch. Please refer to the SWM user guide for more information.

Console connection

The connection to the console is accessed through the DB-9 RS232 connector on the switch marked on the Magnum 6K family of switches as a console port. This interface provides access to the commands the switch can interpret and is called the Command Line Interface (or CLI). This interface can be accessed by attaching a VT100 compatible terminal or a PC running a terminal emulation program to the console port on the Magnum 6K family of switches. USB to serial adapters are also available for laptops or computers that do not native serial ports but have access to USB ports.

MNS-6K Software Updates

Page 25 of the GarrettCom MNS-6K user manual — F IGURE 1 - HyperTerminal screen showing the serial settings
Page 25 · click to enlarge
Page 25

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

The interface through the console or the Console Management Interface (or CMI) enables you to reconfigure the switch and to monitor switch status and performance.

Once the switch is configured with an IP address, the Command Line Interface (or CLI) is also accessible using telnet as well as the serial port. Access to the switch can be either through the console interface or remotely over the network.

The Command Line Interface (CLI) enables local or remote unit installation and maintenance. The Magnum 6K family of switches provides a set of system commands which allow effective monitoring, configuration and debugging of the devices on the network.

Console setup

Connect the console port on the switch to the serial port on the computer using the serial cable listed above. The settings for the HyperTerminal software emulating a VT100 are shown in Figure 1 below. Make sure the serial parameters are set as shown (or bps = 38400, data bits=8, parity=none, stop bits=1, flow control=none).

GarrettCom MNS-6K — Console setup diagram (page 25)
Fig. 3 · Console setup

F IGURE 1 - HyperTerminal screen showing the serial settings

Console screen

Once the console cable is connected to the PC and the software configured, MNS- 6K legal disclaimers and other text scrolls by on the screen.

Page 26 of the GarrettCom MNS-6K user manual — Setting the IP parameters
Page 26 · click to enlarge
Page 26

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

The switch has three modes of operation – Operator (least privilege), Manager and Configuration. The prompts for the switches change as the switch changes modes from Operator to Manager to Configuration. The prompts are shown in Figure 2 below, with a brief explanation of what the different prompts indicate.

Magnum6K> Operator Level – for running operations queries Magnum6K# Manager Level – for setting and reviewing commands Magnum6K## Configuration Level – for changing the switch parameter values FIGURE 2 - Prompt indicating the switch model number as well as mode of operation – note the commands to switch between the levels is not shown here.

The prompt can be changed by the user. See the Chapter on Miscellaneous Commands, sub section Prompt for more details. This manual was documented on a Magnum 6K25 switch, and for clarity, the prompt shown in the manual will be Magnum6K25

For additional information on default users, user levels and more, see User Management in this guide.

j

Logging in for the first time

For the first time, use the default user name and passwords assigned by GarrettCom for the Magnum 6K family of switches. They are: Username – manager Password – manager Username – operator Password – operator We recommend you login as manager for the first time to set up the IP address as well as change user passwords or create new users.

Setting the IP parameters

To setup the switch, the IP address and other relevant TCP/IP parameters have to be specified. A new GarrettCom Magnum switch looks for a DHCP or a BootP server. If a DHCP or a BootP server is present, the switch will be assigned an IP address from those servers. Failing to find these servers, the IP address is automatically assigned to 192.168.1.2 with a netmask of 255.255.255.0.

Page 27 of the GarrettCom MNS-6K user manual — MNS-6K Software Updates
Page 27 · click to enlarge
Page 27

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Should a situation arise when there are multiple new switches powered up at the same time, there could be a situation of duplicate IP addresses. In this situation, only one Magnum switch will be assigned the IP address of 192.168.1.2 and netmask of 255.255.255.0. The other switches will not be assigned an IP address till the static IP address of 192.168.1.2 is freed up or reassigned. To change the IP address, please ensure that the IP address to be assigned to the switch is known or contact your system/network administrator to get the IP address information. Follow the steps listed below to configure the IP address manually.

  • Ensure the power is off
  • Follow the steps described above for connecting the console cable and setting the console software
  • Power on the switch
  • Once the login prompt appears, login as manager using default password (manager)
  • Configure the IP address, network mask and default gateway as per the IP addressing scheme for your network
  • Set the Manager Password (recommended–refer to next section)
  • Save the settings (without saving, the changes made will be lost)
  • Power off the switch (or a software reboot as discussed below)
  • Power on the switch – login with the new login name and password
  • From the PC (or from the switch) ping the IP address specified for the switch to ensure connectivity
  • From the switch ping the default gateway specified (ensure you are connected to the network to check for connectivity) to ensure network connectivity Syntax ipconfig [ip=<ip-address>] [mask=<subnet-mask>] [dgw=<gateway>] [add|del]

Magnum6K25# ipconfig ip=192.168.1.150 mask=255.255.255.0

dgw=192.168.1.10 Magnum6K25# save FIGURE 3 - Setting IP address on the switch

This document assumes the reader is familiar with IP addressing schemes as well as how net mask is used and how default gateways and routers are used in a network.

Page 28 of the GarrettCom MNS-6K user manual — MNS-6K Software Updates
Page 28 · click to enlarge
Page 28

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Reboot gives an opportunity to save the configuration prior to shutdown. For a reboot – simply type in the command “reboot”. (Note – even though the passwords are not changed, they can be changed later.)

Magnum6K25# reboot Proceed on rebooting the switch? [ 'Y' or 'N' ] Y

Do you wish to save current configuration? [ 'Y' or 'N' ] Y Magnum6K25# FIGURE 4 - Rebooting the switch

MNS-6K forces an answer the prompts with a “Y” or a “N” to prevent accidental keystroke errors and loss of work. The parameters can be viewed at any time by using the ‘show’ command. The show command will be covered in more detail later in various sections throughout the document.

Magnum6K25# show setup Version : Magnum 6K25 build 3.7.1 Sep 27 2007 16:41:37 MAC Address : 00:20:08:03:05:09 IP Address : 192.168.5.5 Subnet Mask : 255.255.255.0 Gateway Address : 192.168.5.1 CLI Mode : Manager System Name : Magnum 6K25 System Description : 25 Port Modular Ethernet Switch System Contact : support@garrettcom.com System Location : Fremont, CA System ObjectId : 1.3.6.1.4.1.553.12.6 System Serial No : 43576812 Original Factory Config Code : 6K25-8TP Magnum6K25# show sysconfig System Name : Magnum6K25 System Contact : support@garrettcom.com System Location : HO, Fremont, CA Boot Mode : manual Inactivity Timeout(min) : 10 Address Age Interval(min) : 300 Inbound Telnet Enabled : Yes Web Agent Enabled : Yes Time Zone : GMT-08hours:00minutes Day Light Time Rule : USA System UpTime : 36 Days 7 Hours 49 Mins 48 Secs Magnum6K25# FIGURE 5 - Viewing the basic setup parameters. You can use ‘show setup’ or ‘show sysconfig’ to view setup parameters

Page 29 of the GarrettCom MNS-6K user manual — User management
Page 29 · click to enlarge
Page 29

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Some of the parameters in the Magnum 6K family of switches are shown above. The list of parameters below indicates some of the key parameters on the switch and the recommendations for changing them (or optionally keeping them the same).

Privilege levels

Two privilege levels are available - Manager and Operator. Operator is at privilege level 1 and the Manager is at privilege level 2 (the privilege increases with the levels). For example, to set up a user for basic monitoring capabilities use lower number or operator level privilege (Level 1)

The Manager level provides all Operator level privileges plus the ability to perform system-level actions and configuration commands. To select this level, enter the ‘enable <user-name>’ command at the Operator level prompt and enter the Manager password, when prompted.

For example, switching from an Operator level to manager level, using the ‘enable’ command is shown below in Figure 6

Magnum6K25> enable manager Password: ******* Magnum6K25# FIGURE 6 - Switching users and privilege levels. Note the prompt changes with the new privilege level.

Operator Privileges

Operator privileges allow views of the current configurations but do not allow changes to the configuration. A ">" character delimits the Operator-level prompt.

Manager Privileges

Manager privileges allow configuration changes. The changes can be done at the manager prompt or for global configuration as well as specific configuration. A “#” character delimits any Manager prompt.

User management

A maximum of five users can be added per switch. Users can be added, deleted or changed from a manager level account. There can be more than one manager account, subject to the maximum number of users on the switch being restricted to five.

Syntax enable <user-name>

Page 30 of the GarrettCom MNS-6K user manual — In this example, password for ‘peter’ was modified. Modify the Privilege Level
Page 30 · click to enlarge
Page 30

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Add User

To add a user, use the command “add” as shown below. The user name has to be a unique name and can be up to 24 characters long. The password is recommended to be at least 8 characters long with a mix of upper case, lower case, numbers and special characters.

Syntax add user=<name> level=<number>

Magnum6K25# user Magnum6K25(user)## add user=peter level=2 Enter User Password:****** Confirm New Password:****** Magnum6K25(user)## FIGURE 7 - Adding a user with Manager level privilege

In this example, user ‘peter’ was added with Manager privilege. Delete User

Syntax delete user=<name> Magnum6K25(user)##delete user=peter Confirm User Deletion(Y/N): Y User successfully deleted Magnum6K25(user)## FIGURE 8 - Deleting a user

In this example, user ‘peter’ was deleted. Modify Password

Syntax passwd user=<name> Magnum6K25(user)## passwd user=peter Enter New Password:****** Confirm New Password :****** Password has been modified successfully Magnum6K25(user)## FIGURE 9 - Changing the password for a specific user

In this example, password for ‘peter’ was modified. Modify the Privilege Level

Syntax chlevel user=<name> level=<number>

Page 31 of the GarrettCom MNS-6K user manual — Modify Access Privileges for a user
Page 31 · click to enlarge
Page 31

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25(user)## chlevel user=peter level=1 Access Permission Modified Magnum6K25(user)## FIGURE 10 - Changing the privilege levels for a user

In this example, user ‘peter’ was modified to Operator privileges. Modify Access Privileges for a user

Syntax useraccess user=<name> service=<telnet|web> <enable|disable> Where user=<name> specifies the user id service=<telnet|web> specifies which service (telnet or web) the user has access to <enable|disable> specifies whether the services are allowed or not allowed. Magnum6K25# user Magnum6K25(user)## add user=peter level=2 Enter User Password :***** Confirm New Password :***** Magnum6K25(user)## useraccess user=peter service=telnet disable Telnet Access Disabled. FIGURE 11 – Creating user access privileges

After this command, user Peter will not have telnet access to the switch. User Peter only has console access or SWM access.

The user “peter” has to be added before this command can be successfully executed.

Page 32 of the GarrettCom MNS-6K user manual — Viewing options for a command
Page 32 · click to enlarge
Page 32

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Help

Typing the ‘help’ command lists the commands you can execute at the current privilege level. For example, typing ‘help’ at the Operator level shows

Magnum6K25> help logout ping set terminal telnet walkmib Contextless Commands: ! ? clear enable exit help show whoami alarm Magnum6K25> FIGURE 12 - Help command

Displaying Help for an Individual Command

Help for any command that is available at the current context level can be viewed by typing help followed by enough of the command string to identify the command.

Syntax help <command string>

For example, to list the Help for the ‘set time’ command

Magnum6K25# help set time set time : Sets the device Time Usage set time hour= min= sec= [zone=GMT[+/-]hh:mm] Magnum6K25# FIGURE 13 - Help for a specific command

Viewing options for a command

The options for a specific command can be displayed by typing the command and pressing enter. Syntax command <Enter>

Magnum6K25# show <Enter>

Page 33 of the GarrettCom MNS-6K user manual — Context help
Page 33 · click to enlarge
Page 33

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Usage show active-stp show active-snmp show active-vlan show address-table show age show alarm show arp show auth show backpressure show bootmode --more-- FIGURE 14 - Options for the ‘show’ command

Context help

Other ways to display help, specifically, with reference to a command or a set of commands, use the TAB key.

Syntax <TAB> Syntax <Command string> <TAB> Syntax <First character of the command> <TAB>

For example, following the syntax listed above, the key will list the available commands in the particular privilege level:

Magnum6K25> <TAB>? alarm clear enable exit help logout ping set show telnet terminal walkmib whoami Magnum6K25> FIGURE 15 - Listing commands available (at the operator level)

OR Magnum6K25> s <TAB> set show Magnum6K25> FIGURE 16 - Listing commands starting with a specific character

Page 34 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 34 · click to enlarge
Page 34

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

OR

Magnum6K25> se<TAB> password timeout vlan Magnum6K25> set FIGURE 17 - Listing commands options – note the command was not completed and the TAB key completed the command.

Exiting

To exit from the CLI interface and terminate the console session use the ‘logout’ command. The logout command will prompt you to ensure that the logout was not mistakenly typed. Syntax logout

Magnum6K25# logout Logging out from the current session...[ 'Y' or 'N'] Y Connection to the host lost FIGURE 18 – logout command

List of commands in this chapter

Syntax ipconfig [ip=<ip-address>] [mask=<subnet-mask>] [dgw=<gateway>]

[add|del] – to set IP address on the switch Syntax save – save changes made to the configuration Syntax reboot – restart the switch – same effect as physically turning off the power Syntax show setup – show setup parameters Syntax show config – show setup parameters configured Syntax enable <user-name> - changing the privilege level Syntax add user=<name> level=<number> - adding a user Syntax delete user=<name> - deleting a user

Page 35 of the GarrettCom MNS-6K user manual — Context help
Page 35 · click to enlarge
Page 35

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax passwd user=<name> - changing a password for a user Syntax chlevel user=<name> level=<number> - changing the user privilege level Syntax help <command string> - help for a specific command Syntax command <Enter> - options for a command Syntax <TAB> - listing all commands available at the privilege level Syntax <command string> <TAB> - options for a command Syntax <first character of the command> <TAB> - listing commands starting with the character Syntax logout – logout from the CLI session Syntax useraccess user=<name> service=<telnet|web> <enable|disable>

Page 36 of the GarrettCom MNS-6K user manual — Importance of an IP address
Page 36 · click to enlarge
Page 36

Chapter 3

3 – IP Address and System Information

First simple steps to follow…

T

his section explains how the Magnum 6K family of switches can be setup using other automatic methods such as bootp and DHCP. Besides this, other parameters required for proper operation of the switch in a network are discussed.

IP Addressing j It is assumed that the user has familiarity with IP addresses, classes of IP addresses and related netmask schemes (e.g. class A, Class B and Class C addressing).

Importance of an IP address

Without an IP address, the switch will operate as a standalone Layer 2 switch. Without an IP address, you cannot

  • Use the web interface to manage the switch
  • Use telnet to access the CLI
  • Use any SNMP Network Management software to manage the switch
  • Use NTP protocol or an NTP server to synchronize the time on the switch
  • Use TFTP or FTP to download the configurations or upload software updates
  • Run ping tests to test connectivity

To set the IP address, please refer to the section in Chapter 2 – Setting IP Parameters.

Once the IP address is set, the CLI can be accessed via the telnet programs as well as the console interface. From now on – all commands discussed are accessible from the CLI – irrespective of the access methods – serial port or in band using telnet.

Page 37 of the GarrettCom MNS-6K user manual — Bootp Database
Page 37 · click to enlarge
Page 37

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

To verify the IP address settings, the ‘show ipconfig’ command can be used.

Magnum6K25> show ipconfig IP Address : 192.168.1.150 Subnet Mask : 255.255.255.0 Default Gateway : 192.168.1.10 Magnum6K25> FIGURE 19 - Checking the IP settings

Besides manually assigning IP addresses, there are other means to assign an IP address automatically. The two most common procedures are using DHCP and bootp.

j

DHCP is commonly used for setting up addresses for computers, users and other user devices on the network. bootp is the older cousin of DHCP and is used for setting up IP addresses of networking devices such as switches, routers, VoIP phones and more. Both of them can work independent of each other. Both of them are widely used in the industry. It’s best to check with your network administrator as to what protocol to use and what the related parameters are. DHCP and bootp require respective services on the network. DHCP and bootp can automatically assign an IP address. It is assumed that the reader knows how to setup the necessary bootp parameters (usually specified on Linux/UNIX systems in /etc/boopttab1).

Bootp Database

Bootp keeps a record of systems supported in a database – a simple text file. On most systems, the bootp service is not started as a default and has to be enabled. A sample entry by which the bootp software will look up the database and update the IP address and subnet mask of the switch would be as follows

M6k25switch:\ ht=ether:\ ha=002006250065:\ ip=192.168.1.88:\ sm=255.255.255.0:\ gw=192.168.1.1:\ hn:\ vm=rfc1048 where M6k25switch: is a user-defined symbolic name for the switch

1 Note – on Windows systems – the location of the file will vary depending on which software is being used.

DHCP and bootp

Page 38 of the GarrettCom MNS-6K user manual — Configuring Auto/DHCP/Bootp/Manual
Page 38 · click to enlarge
Page 38

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

ht: is the “hardware type”. For the Magnum 6K family of switches, set this to ether (for Ethernet). This tag must precede the “ha” tag.

hais the “hardware address”. Use the switch’s 12-digit MAC address
ipis the IP address to be assigned to the switch
smis the subnet mask of the subnet in which the switch is installed

Configuring Auto/DHCP/Bootp/Manual

By default, the switch is configured for ‘auto’. As describer earlier in Chapter 2, in the auto mode, the switch will first look for a DHCP server. If a DHCP server is not found, it will then look for a BootP server. If that server is not found, the switch will first inspect to see if the IP address 192.168.1.2 with a netmask of 255.255.255.0 is free. If the IP address is free, MNS-6K will assign the switch that IP address. If the address is not free, MNS-6K will poll the network for DHCP server then BootP server then check if the IP address 192.68.1.2 is freed up. This mode of assigning the IP address can be changed by using the ‘set bootmode’ command. Syntax set bootmode type=<dhcp|bootp|manual|auto>

[bootimg=<enable|disable>] [bootcfg=[<enable|disable>] – assign the boot mode for the switch Where <dhcp|bootp|manual|auto> - where

dhcp – look only for DHCP servers on the network for the IP address. Disable

bootp or other modes bootp – look only for bootp servers on the network. Disable dhcp or other mode manual – do not set the IP address automatically auto - the switch will first look for a DHCP server. If a DHCP server is not found,

it will then look for a BootP server. If that server is not found, the switch will check to see if the switch had a pre-configured IP address. If it did, the switch would be assigned that IP address. If the switch did not have a pre-configured IP address, it would inspect if the IP address 192.168.1.2 with a netmask of 255.255.255.0 is free. If the IP address is free, MNS-6K will assign the switch that IP address. If the address is not free, MNS-6K will poll the network for DHCP server then BootP server then check if the IP address 192.68.1.2 is freed up bootimg=<enable|disable> - valid with type=bootp only. This option allows the

switch to load the image file from the BootP server. This is useful when a new switch is put on a network and the IT policies are set to load only a specific MNS-6Kimage which is supported and tested by IT personnel. bootcfg=<enable|disable> - valiad with type=bootp only. This option allows the

switch to load the configuration file from the BootP server. This is useful when a new

Page 39 of the GarrettCom MNS-6K user manual — Using Telnet
Page 39 · click to enlarge
Page 39

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

switch is put on a network and the specific configurations are loaded from a centralized BootP server

Magnum6K25# set bootmode type=dhcp Save Configuration and Restart System Magnum6K25# set bootmode type=auto Save Configuration and Restart System Magnum6K25# set bootmode type=bootp bootimg=enable bootcfg=disable Network application image download is enabled. Network application config download is disabled. Save Configuration and Restart System Magnum6K25# FIGURE 20 - Changing the boot mode of the switch

Using Telnet

By default, the telnet client is enabled on the GarrettCom Magnum 6K family of switches. MNS-6K supports five simultaneous sessions on a switch – four telnet sessions and one console session. This allows many users to view, discuss or edit changes to the MNS-6K. This also becomes useful as two remote people want to view the commands and other settings on the switch. The telnet client can be disabled by using the “telnet disable” command. Telnet can also be disabled for a specific user by using the “useraccess” command discussed in Chapter 2. Multiple telnet sessions started from the CLI interface or the command line are serviced by MNS-6K in a round robin fashion – i.e. one session after another. If one telnet session started from MNS-6K interface is downloading a file, the other windows will not be serviced till the file transfer is completed. Syntax telnet <enable|disable>

Magnum6K25# configure access Magnum6K25(access)## telnet enable Access to Telnet already enabled Magnum6K25(access)## exit Magnum6K25# FIGURE 21 - Changing telnet access – note in this case, the enable command was repeated without any effect to the switch

The ‘show console’ command can show the status of the telnet client as well as other console parameters.

Page 40 of the GarrettCom MNS-6K user manual — Using Telnet
Page 40 · click to enlarge
Page 40

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# show console Console/Serial Link Inbound Telnet Enabled : Yes Outbound Telnet Enabled : Yes Web Console Enabled : Yes SNMP Enabled : Yes Terminal Type : VT100 Screen Refresh Interval (sec) : 3 Baud Rate : 38400 Flow Control : None Session Inactivity Time (min) : 10 Magnum6K25# FIGURE 22 - Reviewing the console parameters – note telnet is enabled

Users can telnet to a remote host from the Magnum 6K family of switches. Syntax telnet <ipaddress> [port=<port number>]

The default port for telnet is 23. Magnum6K25# show ipconfig IP Address : 192.168.1.11 Subnet Mask : 255.255.255.0 Gateway Address : 192.168.1.1 Magnum6K25# telnet 192.168.1.1 port=2097 FIGURE 23 - Example of a telnet session

While MNS-6K times out an idle telnet session, it may be useful to see who is currently connected to the switch. It may also be useful for a person to remotely terminate a telnet session. To facilitate this, MNS-6K supports two commands

Syntax kill session id=<session> - terminate a telnet session

Syntax show session

Page 41 of the GarrettCom MNS-6K user manual — [stop=<1|1.5|2>] [flowctrl=<none|xonxoff>]
Page 41 · click to enlarge
Page 41

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# user Magnum6K25(user)## useraccess user=peter service=telnet enable Telnet Access Enabled. Magnum6K25(user)## exit Magnum6K25# show session Current Sessions: SL # Session Id Connection User Name User Mode 1 1 163.10.10.14 manager Manager 2 2 163.11.11.15 peter Manager 3 3 163.12.12.16 operator Operator Magnum6K25# kill session id=3 Session Terminated. Magnum6K25# FIGURE 24 – managing and viewing multiple telnet sessions

In the above example, the user with user-id peter is given telnet access (which was disabled earlier in Chapter 2). Then multiple users telnet into the switch. This is shown using the “show session” command. The user operator session is then terminated using the “kill session” command.

The default port – port 23 is used for telnet.

A maximum of four simultaneous telnet sessions are allowed at any time on the switch. The commands in these telnet windows are executed in a round robin – i.e. if one window takes a long time to finish a command, the other windows may encounter a delay before the command is completed. For example, if one window is executing a file download, the other windows will not be able to execute the command before the file transfer is completed. Another example, if a outbound telnet session is started from the switch (through a telnet window) then the other windows will not be able to execute a command till the telnet session is completed.

Setting serial port parameters

To be compliant with IT or other policies the console parameters can be changed from the CLI interface. This is best done by setting the IP address and then telnet over to the switch. Once connected using telnet, the serial parameters can be changed. If you are using the serial port, remember to set the VT-100 emulation software properties to match the new settings. Syntax set serial [baud=<rate>] [data=<5|6|7|8>] [parity=<none|odd|even>]

[stop=<1|1.5|2>] [flowctrl=<none|xonxoff>]

Where = standard supported baud rates

Page 42 of the GarrettCom MNS-6K user manual — System parameters
Page 42 · click to enlarge
Page 42

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# show serial Baud Rate : 38400 Data : 8 Parity : No Parity Stop : 1 Flow Control : None FIGURE 25 - Querying the serial port settings

System parameters

The system parameters can be queried and changed. To query the system parameters, two commands are used frequently. They are ‘show sysconfig’ and ‘show setup’. Both the commands are shown below.

Magnum6K25# show setup Version : Magnum 6K25 build 3.7.1 Sep 27 2007 16:41:37 MAC Address : 00:20:08:03:05:09 IP Address : 192.168.5.5 Subnet Mask : 255.255.255.0 Gateway Address : 192.168.5.1 CLI Mode : Manager System Name : Magnum 6K25 System Description : 25 Port Modular Ethernet Switch System Contact : support@garrettcom.com System Location : Fremont, CA System ObjectId : 1.3.6.1.4.1.553.12.6 System Seriial No. : 43576812 Original Factory Config Code : 6K25-8TP Magnum6K25#

FIGURE 26 - System parameters using the show setup command. Most parameters here cannot be changed

Page 43 of the GarrettCom MNS-6K user manual — Using Telnet
Page 43 · click to enlarge
Page 43

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# show sysconfig System Name : Magnum6K25 System Contact : support@garrettcom.com System Location : HO, Fremont, CA Boot Mode : manual Inactivity Timeout(min) : 10 Address Age Interval(min) : 300 Inbound Telnet Enabled : Yes Web Agent Enabled : Yes Time Zone : GMT-08hours:00minutes Day Light Time Rule : USA System UpTime : 7 Days 12 Hours 30 Mins 46 Secs Magnum6K25# FIGURE 27 - System parameters using the show sysconfig command. Most parameters here can be changed.

System variables can be changed. Below is a list of system variables which GarrettCom recommends changing. System Name: Using a unique name helps you to identify individual devices in a network.

System Contact and System Information: This is helpful for identifying the administrator responsible for the switch and for identifying the locations of individual switches. To set these variables, change the mode to be SNMP configuration mode from the manager mode. Syntax snmp Syntax setvar [sysname|syscontact|syslocation]=<string> where string is a character string, maximum 24 characters long

Magnum6K25# snmp Magnum6K25(snmp)## setvar ? setvar : Configures system name, contact or location Usage: setvar [sysname|syscontact|syslocation]= Magnum6K25(snmp)## setvar syslocation=Fremont System variable(s) set successfully Magnum6K25(snmp)## exit Magnum6K25# FIGURE 28 - Setting the system name, system location and system contact information

Page 44 of the GarrettCom MNS-6K user manual — Date and time
Page 44 · click to enlarge
Page 44

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Date and time

It may be necessary to set the day, time or the time zone manually. This can be done by using the ‘set’ command with the necessary date and time options. These are listed below:

Syntax set timezone GMT=[+ or -] hour=<0-14> min=<0-59> Syntax set date year=<2001-2035> month=<1-12> day=<1-31>

[format=<mmddyyyy|ddmmyyyy|yyyymmdd>] Syntax set time hour=<0-23> min=<0-59> sec=<0-59> [zone=GMT[+/-]hh:mm] Thus to set the time to be 08:10 am in the -8 hours from GMT (PST or time zone on west coast of USA) and to set the date to be 15 October 2003, the following set of commands are used.

Magnum6K25# set time hour=8 min=30 sec=0 zone=GMT-8:00 success in setting device time Magnum6K25# show time Time : 8:30:04 Magnum6K25# show timezone Timezone : GMT-08hours:00minutes Magnum6K25# set date year=2003 month=10 day=15 Success in setting device date Magnum6K25# show date System Date : Wednesday 10-15-2003 (in mm-dd-yyyy format) Magnum6K25# FIGURE 29 - Setting the system date, time and time zone

Rebooting the switch resets the time to the default. Synchronizing with the time server resets the time. Other relevant date and time commands are:

Syntax set timeformat format=<12|24> Syntax set daylight country=< country name>

Magnum6K25# set daylight ? set daylight : Sets the day light location Usage set daylight country= Magnum6K25# set daylight country=USA Success in setting daylight savings to the given location/country USA Magnum6K25# show daylight

Page 45 of the GarrettCom MNS-6K user manual — Network time
Page 45 · click to enlarge
Page 45

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Daylight savings location nameUSA Magnum6K25# F IGURE 30 - Setting the system daylight saving time

See Appendix 3 for additional information on Daylight Savings Time. The lists of countries for the time zone are

Australia, Belgium, Canada, Chile, Cuba, Egypt, France, Finland, Germany, Greece, Iraq, Italy, London, Namibia, Portugal, Russia, Spain, Sweden, Switzerland, Syria, USA

Network time

Many networks synchronize the time using a Network time server. The network time server provides time to the different machines using the Simple Network Time Protocol (SNTP). To specify the SNTP server, one has to 1) Set the IP parameters on the switch 2) Define the SNTP parameters

To set the SNTP parameter, enter the SNTP configuration mode from the manager. The ‘setsntp, sync, sntp’ commands can then be used to setup the time synchronization automatically from the SNTP server. Note it is not sufficient to setup the SNTP variables. Make sure to setup the synchronization frequency as well as enable SNTP. The list of relevant commands is listed below.

Syntax setsntp server = <ipaddress> timeout = <1-10> retry = <1-3> Syntax sync [hour=<0-24>] [min=<0-59>] (default = 24 hours)

The time zone and daylight savings time information have to be set for SNTP server to set the proper time Syntax sntp [enable|disable]

For example, to set the SNTP server to be 204.65.129.2012 (with a time out of 3 seconds and a number of retries set to 3 times); allowing the synchronization to be ever 5 hours, the following commands are used

2 There are number of public NTP servers. Search on the internet using ‘NTP Servers’ yields the necessary server IP addresses.

Page 46 of the GarrettCom MNS-6K user manual — Saving and loading configuration
Page 46 · click to enlarge
Page 46

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# sntp Magnum6K25(sntp)## setsntp server=204.65.129.201 timeout=3 retry=3 SNTP server is added to SNTP server database Magnum6K25(sntp)## sync hour=5 Magnum6K25(sntp)## sntp enable

Do not forget to enable sntp for time synchronization.

SNTP is already enabled. Magnum6K25(sntp)## exit Magnum6K25(sntp)# FIGURE 31 - Setting up SNTP services

Saving and loading configuration

After configuration changes are made, all the changes are automatically registered but not saved i.e. the effect of the change is immediate, however, if power fails, the changes are not saved and restored, unless the changed are saved using the save command. It is also a good practice to save the configuration on another server on the network using the tftp or ftp protocols. Once the configuration is saved – the saved configuration can be loaded to restore back the settings. At this time the configuration parameter saved or loaded are not in a human readable format. The commands for saving and loading configurations on the network are:

Syntax saveconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>] Syntax loadconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>] Make sure the machine specified by the IP address has the necessary services running on it. For serial connections, x-modem or other alternative methods can be used. File name in many situations has to be a unique file name as over-writing files is not permitted by most ftp and tftp servers (or services). Only alpha-numeric characters are allowed in the file name – special characters like !@#$%&*(\|){/};[,’]” (or other control characters e.g. ^G) are not allowed

Magnum6K25# saveconf mode=tftp 192.168.10.1 file=mag6Kmain Do you wish to upload the configuration? [ 'Y' or 'N'] Y FIGURE 32 - Saving the configuration on a tftp server

The “saveconf” and “loadconf” commands are used often to update new software to the Magnum 6K family of switches. These commands will be obsoleted in the next release and replaced with the “ftp” or “tftp” or “xmodem” commands listed below. It is advised to start using these commands instead of “saveconf” and “loadconf”. Before the

Page 47 of the GarrettCom MNS-6K user manual — Using Telnet
Page 47 · click to enlarge
Page 47

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

software is updated, it is advised to save the configurations. The re-loading of the configuration is not usually necessary; however, in certain situations it maybe needed and it is advised to save configurations before a software update. The ‘loadconf’ command requires a reboot for the new configuration to be active. Without a reboot the older configuration is used by the Magnum 6K family of switches. When Reboot is selected, the user is prompted: ‘Reboot Y/N’. Select ‘Y’, the prompt is then: ‘Save Current Configuration?’ You must select ‘No’.

Along with the ftp command listed below, MNS-6K also supports normal ftp as well as passive ftp. Passive FTP is used by many companies today to work with firewall policies and other security policies set by companies. The commands for setting the type of ftp are:

Syntax set ftp mode=<normal|passive> - set the ftp mode of operation3

Syntax show ftp- display the current ftp operation mode

With MNS-6K additional capabilities have been added to save and load configurations. The commands are: Syntax ftp <get|put|list|del> [type=<app|config|oldconf|script|hosts|log>]

[host=<hostname>] [ip=<ipaddress>] [file=<filename>] [user=<user>] [pass=<password>] – upload and download information using ftp command Where <get|put|list|del> - different ftp operations [type=<app|config|oldconf|script|hosts|log>] – optional type field. This

is useful to specify whether a log file or host file is uploaded or downloaded. This can also perform the task of exporting a configuration file or uploading a new image to the switch [host=<hostname>] [ip=<ipaddress>] [file=<filename>] [user=<user>]

[pass=<password>] – parameters associated with ftp server for proper communications with the server Syntax tftp <get|put> [type=<app|config|oldconf|script|hosts|log>]

[host=<hostname>] [ip=<ipaddress>] [file=<filename>] – upload and download information using tftp command Where <get|put> - different tftp operations – get a file from the server or put the

information on the server

3 FTP uses a set of separate ports for the data stream and command stream. This causes problems in security conscious companies who prefer that the client initiate the file transfer as well as the stream for the commands. To accommodate that, ftp added the capability called “passive ftp” in which the client initiating the connection initiates both the data and command connection request. Most companies prefer passive ftp and GarrettCom MNS-6K provides means to operate in those environments.

Page 48 of the GarrettCom MNS-6K user manual — Using Telnet
Page 48 · click to enlarge
Page 48

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

[type=<app|config|oldconf|script|hosts|log>] – optional type field. This

is useful to specify whether a log file or host file is uploaded or downloaded. This can also perform the task of exporting a configuration file or uploading a new image to the switch [host=<hostname>] [ip=<ipaddress>] [file=<filename>] – parameters

associated with tftp server for proper communications with the server Syntax xmodem <get|put> [type=<app|config|oldconf|script|hosts|log>] –

upload and download information using xmodem command and console connection

Where <get|put> - different xmodem file transfer operations – get a file from the server

or put the information on the server [type=<app|config|oldconf|script|hosts|log>] – optional type field. This

is useful to specify whether a log file or host file is uploaded or downloaded. This can also perform the task of exporting a configuration file or uploading a new image to the switch The details are conceptually explained in the figure below.

GarrettCom MNS-6K — Using Telnet diagram (page 48)
Fig. 4 · Using Telnet

FIGURE 33 – Based on the ftp or tftp or xmodem commands – the MNS-6K based switch can upload or download different types of files and images .Other files such as log files, hosts file can also be saved or loaded onto a switch

Page 49 of the GarrettCom MNS-6K user manual — Config files
Page 49 · click to enlarge
Page 49

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Prior to Release 3.2, the configuration was saved only as a binary object (file). With Release 3.2 and beyond, the configuration can be saved in the older format – binary object or in a newer format as an ASCII (readable) file. The new format is preferred by GarrettCom and GarrettCom recommends all configuration files be saved in the new format. GarrettCom recommends saving the configuration in the old format only if there are multiple Magnum 6K family of switches on the network and they all run different versions of MNS-6K. GarrettCom recommends to upgrade all switches to the most current release of MNS-6K.

Config files

As shown in the figure above, MNS-6K can now use the ftp, tftp or xmodem commands to upload and download information to the server running the proper services. One useful capability provided in MNS-6K is the capability to export the CLI commands (as described in this manual) used to configure the switch. To do that, for example, using the tftp command, the sequence of commands are shown below

Magnum 6K25# show ftp Current FTP Mode: NORMAL Magnum 6K25# set ftp mode=passive FTP Set to Passive Mode Magnum 6K25# show ftp Current FTP Mode: PASSIVE Magnum 6K25# set ftp mode=normal FTP Set to Normal Mode Magnum 6K25# show ftp Current FTP Mode: NORMAL Magnum6K25# ftp put type=config ip=192.168.5.2 file=config Do you wish to export configuration file? [ 'Y' or 'N'] Y Successfully exported the configuration Magnum6K25# FIGURE 34 – commands to save the configuration using ftp. Similar options will be specified using tftp etc. When using the ftp command, use the host command discussed later in this section to define the ftp server

After saving the contents of the saved configuration file are as follows

################################################################ # Copyright (c) 2001-2005 GarrettCom, Inc All rights reserved. # RESTRICTED RIGHTS # # Use, duplication or disclosure is subject to U.S. Government # restrictions as set forth in Sub-division (b)(3)(ii) of the

Page 50 of the GarrettCom MNS-6K user manual — Config files
Page 50 · click to enlarge
Page 50

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

# rights in Technical Data and Computer Software clause at # 52.227-7013. # # This file is provided as a sample template to create a backup # of Magnum 6K switch configurations. As such, this script # provides insights into the configuration of Magnum 6K switch's # settings. GarrettCom recommends that modifications of this # file and the commands should be verified by the User in a # test environment prior to use in a "live" production network. # All modifications are made at the User's own risk and are # subject to the limitations of the GarrettCom software End User # License Agreement (EULA). Incorrect usage may result in # network shutdown. GarrettCom is not liable for incidental or # consequential damages due to improper use. ################################################################ #Magnum 6KQ build 3.7.1 Sep 27 2007 16:41:37 #Modules: 39 99 86 0 #Slot A: 4 Port TP-MDIX Module #Slot B: 2 Port Fiber10 Module #Slot C: 4 Port Fiber100 Module #Slot D: 1 10/100/1000T 1 Giga SFP-1000 ########################################################## # System Manager - This area configures System related # # information. # ########################################################## set bootmode type=auto set timeout=10 access telnet enable snmp enable web enable ssl enable exit ########################################################## # User Accounts - This area configures user accounts for # # accessing this system. # ########################################################## user add user=manager level=2 pass=manager useraccess user=manager service=telnet enable useraccess user=manager service=web enable useraccess user=manager service=acl enable add user=operator level=1 pass=operator ########################################################## <additional lines deleted for succinct viewing> FIGURE 35 – Contents of the config file

GarrettCom MNS-6K — Config files diagram (page 50)
Fig. 5 · Config files
Page 51 of the GarrettCom MNS-6K user manual — Displaying configuration
Page 51 · click to enlarge
Page 51

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

computed and stored in the file will not be matched. Should you want to edit, edit the System portion of the file only. GarrettCom recommends editing the “script” file (see below)

To ease the process of uploading and executing a series of commands, the MNS-6K commands are: Syntax host <add|edit|del> name=<host-name> [ip=<ipaddress>] [user=<user>]

[pass=<password>] – create a host entry for accessing host. This is equivalent to creating a host table on many systems. Maximum of 10 such entries are allowed Syntax show host – displays the host table entries

Magnum6K25# access Magnum6K25(access)## host Usage host name= [ip=] [user=] [pass=] Magnum6K25(access)## host add name=server ip=192.168.5.2 Host added successfully Magnum6K25(access)## show host No Host Name IP Address User Password ==================================================================== 1 server 192.168.5.2 -- ****** 2 -- 3 -- 4 -- 5 -- 6 -- 7 -- 8 -- 9 -- 10 -- Magnum 6K25(access)## FIGURE 36 – Creating host entries on MNS-6K

Displaying configuration

To display the configuration or to view specific modules configured, the ‘show config’ command is used as described below.

Syntax show config [module=<module-name>]

Page 52 of the GarrettCom MNS-6K user manual — Config files
Page 52 · click to enlarge
Page 52

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Where module-name can be

GarrettCom MNS-6K — Config files diagram (page 52)
Fig. 6 · Config files

Name Areas affected system IP Configuration, Boot mode, Users settings (e.g. login names, passwords) event Event Log and Alarm settings port Port settings, Broadcast Protection and QoS settings bridge Age time setting stp STP, RSTP, S- Ring and LLL settings ps Port Security settings mirror Port Mirror settings sntp SNTP settings llan VLAN settings gvrp GVRP settings snmp SNMP settings web Web and SSL/TLS settings tacacs TACACS+ settings auth 802.1x Settings igmp IGMP Settings smtp SMTP settings

If the module name is not specified the whole configuration is displayed.

Magnum6K25# show config [HARDWARE] type=Magnum6K25 slotB=8 Port TP Module ########################################################## # System Manager - This area configures System related # # information. # ########################################################## [SYSTEM] ***Edit below this line only**** system_name=Main system_contact=someone@joe.com system_location=Sunnyvale, CA boot_mode=manual system_ip=192.168.1.15 system_subnet=0.0.0.0 system_gateway=192.168.1.11 idle_timeout=10 telnet_access=enable snmp_access=enable web_access=enable --more—

Page 53 of the GarrettCom MNS-6K user manual — Config files
Page 53 · click to enlarge
Page 53

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

<additional lines deleted for succinct viewing> FIGURE 37 – ‘show config’ command output

Magnum6K25# show config module=snmp [HARDWARE] type=Magnum6K25 slotB=8 Port TP Module ########################################################## # Network Management - This area configures the SNMPv3 # # agent. # ########################################################## [SNMP] engineid=6K_v3Engine defreadcomm=public defwritecomm=private deftrapcomm=public authtrap=disable com2sec_count=0 group_count=0 view_count=1 view1_name=all view1_type=included view1_subtree=.1 view1_mask=ff --more— <additional lines deleted for succinct viewing> FIGURE 38 – displaying specific modules using the ‘show config’ command

Magnum6K25# show config module=snmp,system [HARDWARE] type=Magnum6K25 slotB=8 Port TP Module ########################################################## # System Manager - This area configures System related # # information. # ########################################################## [SYSTEM] ***Edit below this line only**** system_name=Main system_contact=someone@joe.com system_location=Sunnyvale, CA boot_mode=manual system_ip=192.168.1.15 system_subnet=0.0.0.0 system_gateway=192.168.1.11 idle_timeout=10 telnet_access=enable

Page 54 of the GarrettCom MNS-6K user manual — Erasing configuration
Page 54 · click to enlarge
Page 54

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

snmp_access=enable web_access=enable --more— <additional lines deleted for succinct viewing> FIGURE 39 – displaying configuration for different modules. Note – multiple modules can be specified on the command line

Erasing configuration

To erase the configuration and reset the configurations to factory default, you can use the command ‘kill config’. This command is a “hidden command” i.e. the on-line help and other help functions normally do not display this command. The ‘kill config’ command resets everything to the factory default. The reset does not take place till the switch reboots.

It is recommended to save the configuration (using ‘saveconf’ command discussed above) before using the ‘kill config’ command. The ‘kill config’ will also reset the IP address and all other parameters as well unless the save option described below is used.

Syntax kill config [save=module-name] – resets the system configuration. The module-name option does not reset the specific module parameters. The modules are listed below

The module-name can be

Name Areas affected system IP Configuration, Boot mode, Users settings (e.g. login names, passwords) event Event Log and Alarm settings port Port settings, Broadcast Protection and QoS settings bridge Age time setting stp STP, RSTP, S- Ring and LLL settings ps Port Security settings mirror Port Mirror settings sntp SNTP settings llan VLAN settings gvrp GVRP settings snmp SNMP settings web Web and SSL/TLS settings

Page 55 of the GarrettCom MNS-6K user manual — Displaying Serial Number
Page 55 · click to enlarge
Page 55

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

tacacs TACACS+ settings auth 802.1x Settings igmp IGMP Settings smtp SMTP settings

If the module name is not specified the whole configuration is erased.

For example, ‘kill config save=system’ preserves the system IP address, netmask and

default gateway.

Magnum6K25# kill config save=system Do you want to erase the configuration? [ 'Y' or 'N'] Y Successfully erased configuration...Please reboot. FIGURE 40 – Erasing configuration without erasing the IP address

Once the configuration is erased, please reboot the switch for the changes to take effect.

Displaying Serial Number

To display the serial number of the unit, use the command “show setup” as shown below. The command also displays other information related to the switch.

Syntax show setup – display the setup, serial number, factory code information and more

Magnum 6K25# show setup Version : Magnum 6K25 build 3.7.1 Sep 27 2007 16:41:37 MAC Address : 00:20:08:03:05:09 IP Address : 192.168.5.5 Subnet Mask : 255.255.255.0 Gateway Address : 192.168.5.1 CLI Mode : Manager System Name : Magnum 6K25 System Description : 25 Port Modular Ethernet Switch System Contact : support@garrettcom.com System Location : Fremont, CA System ObjectId : 1.3.6.1.4.1.553.12.6 System Seriial No. : 43576812 Original Factory Config Code : 6K25-8TP Magnum 6K25# FIGURE 41 – Display the serial number, factory code and other relevant setup information

Page 56 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 56 · click to enlarge
Page 56

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

List of commands in this chapter

Syntax set bootmode type=<dhcp|bootp|manual|auto> [bootimg=<enable|disable>] [bootcfg=[<enable|disable>] – assign the boot mode for the switch

Where <dhcp|bootp|manual|auto> - where

dhcp – look only for DHCP servers on the network for the IP address. Disable

bootp or other modes bootp – look only for bootp servers on the network. Disable dhcp or other mode manual – do not set the IP address automatically auto - the switch will first look for a DHCP server. If a DHCP server is not found,

it will then look for a BootP server. If that server is not found, the switch will check to see if the switch had a pre-configured IP address. If it did, the switch would be assigned that IP address. If the switch did not have a pre-configured IP address, it would inspect if the IP address 192.168.1.2 with a netmask of 255.255.255.0 is free. If the IP address is free, MNS-6K will assign the switch that IP address. If the address is not free, MNS-6K will poll the network for DHCP server then BootP server then check if the IP address 192.68.1.2 is freed up bootimg=<enable|disable> - valiad with type=bootp only. Allows the switch to load

the image file from the BootP server. This is useful when a new switch is put on a network and the IT policies are set to load only a specific MNS-6Kimage which is supported and tested by IT personnel. bootcfg=<enable|disable> - valiad with type=bootp only. Allows the switch to load

the configuration file from the BootP server. This is useful when a new switch is put on a network and the specific configurations are loaded from a centralized BootP server Syntax telnet <enable|disable> - enables or disables telnet sessions Syntax telnet <ipaddress> [port=<port number>] – telnet from the switch Syntax set serial [baud=<rate>] [data=<5|6|7|8>] [parity=<none|odd|even>]

[stop=<1|1.5|2>] [flowctrl=<none|xonxoff>] – sets serial port parameters Syntax snmp – enter the snmp configuration mode Syntax setvar [sysname|syscontact|syslocation]=<string> - sets the system name, contact and

location information Syntax set timezone GMT=[+ or -] hour=<0-14> min=<0-59> - sets the timezone Syntax set date year=<2001-2035> month=<1-12> day=<1-31>

[format=<mmddyyyy|ddmmyyyy|yyyymmdd>] – sets the date and the format in which the date is displayed

Page 57 of the GarrettCom MNS-6K user manual — Config files
Page 57 · click to enlarge
Page 57

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax set time hour=<0-23> min=<0-59> sec=<0-59> [zone=GMT[+/-]hh:mm] – sets the

time (as well as the timezone) Syntax set timeformat format=<12|24> - sets the display time in the 12/24 hour mode Syntax set daylight country=< country name> - sets the daylight saving time Syntax setsntp server = <ipaddress> timeout = <1-10> retry = <1-3> - setup the SNTP server Syntax sync [hour=<0-24>] [min=<0-59>] – setup the frequency at which the SNTP server is queried Syntax sntp [enable|disable] – enables or disables the SNTP services Syntax saveconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>] – saves the

configuration on the network using tftp, ftp or serial protocols Syntax loadconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>] – loads the previously

saved configuration from the network using tftp, ftp or serial protocols Syntax kill config [save=module_name] – resets the system configuration. The module_name option does not

reset the specific module parameters. The modules are system, event, port, bridge, stp, ps, mirror, sntp, vlan, gvrp and snmp Syntax show session – display telnet sessions active on the switch

Syntax kill session id=<session> - kill a specific telnet session

Syntax set ftp mode=<normal|passive> - set the ftp mode of operation

Syntax show ftp- display the current ftp operation mode Syntax ftp <get|put|list|del> [type=<app|config|oldconf|script|hosts|log>]

[host=<hostname>] [ip=<ipaddress>] [file=<filename>] [user=<user>] [pass=<password>] – upload and download information using ftp command Where <get|put|list|del> - different ftp operations [type=<app|config|oldconf|script|hosts|log>] – optional type field. This is useful

to specify whether a log file or host file is uploaded or downloaded. This can also perform the task of exporting a configuration file or uploading a new image to the switch [host=<hostname>] [ip=<ipaddress>] [file=<filename>] [user=<user>] [pass=<password>] – parameters associated with ftp server for proper communications with the server

Page 58 of the GarrettCom MNS-6K user manual — Other commands
Page 58 · click to enlarge
Page 58

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax tftp <get|put> [type=<app|config|oldconf|script|hosts|log>]

[host=<hostname>] [ip=<ipaddress>] [file=<filename>] – upload and download information using tftp command Where <get|put> - different tftp operations – get a file from the server or put the information

on the server [type=<app|config|oldconf|script|hosts|log>] – optional type field. This is useful

to specify whether a log file or host file is uploaded or downloaded. This can also perform the task of exporting a configuration file or uploading a new image to the switch [host=<hostname>] [ip=<ipaddress>] [file=<filename>] – parameters associated

with tftp server for proper communications with the server Syntax xmodem <get|put> [type=<app|config|oldconf|script|hosts|log>] – upload and

download information using xmodem command and console connection

Where <get|put> - different xmodem file transfer operations – get a file from the server or put

the information on the server [type=<app|config|oldconf|script|hosts|log>] – optional type field. This is useful

to specify whether a log file or host file is uploaded or downloaded. This can also perform the task of exporting a configuration file or uploading a new image to the switch Syntax host <add|edit|del> name=<host-name> [ip=<ipaddress>] [user=<user>]

[pass=<password>] – create a host entry for accessing host. This is equivalent to creating a host table on many systems. Maximum of 10 such entries are allowed Syntax show host – displays the host table entries Syntax climode <script|console|show> - set the interactive CLI mode on (console) or off

(script). To see the mode – use the show option Syntax more <enable|disable|show> - enable or disable the scrolling of lines one page at a time Syntax show config [module=<module-name>] – displays the configuration

Other commands

Syntax configure access – sets the access parameters (e.g. disable telnet session)

Page 59 of the GarrettCom MNS-6K user manual — Config files
Page 59 · click to enlarge
Page 59

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax show ipconfig – shows IP parameters set Syntax show console – reviews console settings Syntax show serial – reviews serial settings Syntax show setup – reviews system parameters Syntax show sysconfig – reviews settable system parameters Syntax show time – shows the system time Syntax show timezone – shows the system timezone Syntax show date – shows the system date Syntax show uptime – shows the amount of time the switch has been operational Syntax show setup – display the setup, serial number, factory code information and more

Page 60 of the GarrettCom MNS-6K user manual — Introduction to IPv6
Page 60 · click to enlarge
Page 60

Chapter 4

4 – IPv6

Next generation IP addressing

his section explains how the access to the GarrettCom Magnum MNS-6K can setup using IPv6 instead of IPv4 addressing described earlier. IPv6 provides a much larger address space and is required today by many. T

Assumptions j

It is assumed here that the user is familiar with IP addressing schemes and has other supplemental material on IPv6, configuration, routing, setup and other items related to IPv6. This user guide does not dwell or probe those details.

Introduction to IPv6

IPv6 is short for "Internet Protocol Version 6". IPv6 is the "next generation" protocol or IPng and was recommended to the IETF to replace the current version Internet Protocol, IP Version 4 ("IPv4"). IPv6 was recommended by the IPv6 (or IPng) Area Directors of the Internet Engineering Task Force at the Toronto IETF meeting on July 25, 1994 in RFC 1752, The Recommendation for the IP Next Generation Protocol. The recommendation was approved by the Internet Engineering Steering Group and made a proposed standard on November 17, 1994. The core set of IPv6 protocols were made an IETF draft standard on August 10, 1998.

IPv6 is a new version of IP which is designed to be an evolutionary step from IPv4. It is a natural increment to IPv4. It can be installed as a normal software upgrade in internet devices and is interoperable with the current IPv4. Its deployment strategy is designed to not have any dependencies. IPv6 is designed to run well on high performance networks (e.g. Gigabit Ethernet, OC-12, ATM, etc.) and at the same time still be efficient for low bandwidth networks (e.g. wireless). In addition, it provides a platform for new internet functionality that will be required in the near future.

IPv6 includes a transition mechanism which is designed to allow users to adopt and deploy IPv6 in a highly diffuse fashion and to provide direct interoperability between IPv4

Page 61 of the GarrettCom MNS-6K user manual — What’s changed in IPV6?
Page 61 · click to enlarge
Page 61

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

and IPv6 hosts. The transition to a new version of the Internet Protocol is normally incremental, with few or no critical interdependencies. Most of today's internet uses IPv4, which is now nearly twenty years old. IPv4 has been remarkably resilient in spite of its age, but it is beginning to have problems. Most importantly, there is a growing shortage of IPv4 addresses, which are needed by all new machines added to the Internet.

IPv6 fixes a number of problems in IPv4, such as the limited number of available IPv4 addresses. It also adds many improvements to IPv4 in areas such as routing and network auto configuration. IPv6 is expected to gradually replace IPv4, with the two coexisting for a number of years during a transition period.

What’s changed in IPV6?

The changes from IPv4 to IPv6 fall primarily into the following categories:

  • Expanded Routing and Addressing Capabilities – IPv6 increases the IP address size from 32 bits to 128 bits, to support more levels of addressing hierarchy and a much greater number of addressable nodes, and simpler auto-configuration of addresses. The scalability of multicast routing is improved by adding a "scope" field to multicast addresses.
  • A new type of address called a "anycast address" is defined, to identify sets of nodes where a packet sent to an anycast address is delivered to one of the nodes. The use of anycast addresses in the IPv6 source route allows nodes to control the path which their traffic flows.
  • Header Format Simplification - Some IPv4 header fields have been dropped or made optional, to reduce the common-case processing cost of packet handling and to keep the bandwidth cost of the IPv6 header as low as possible despite the increased size of the addresses. Even though the IPv6 addresses are four time longer than the IPv4 addresses, the IPv6 header is only twice the size of the IPv4 header.
  • Improved Support for Options - Changes in the way IP header options are encoded allows for more efficient forwarding, less stringent limits on the length of options, and greater flexibility for introducing new options in the future.
  • Quality-of-Service Capabilities - A new capability is added to enable the labeling of packets belonging to particular traffic "flows" for which the sender requests special handling, such as non-default quality of service or "realtime" service.
  • Authentication and Privacy Capabilities - IPv6 includes the definition of extensions which provide support for authentication, data integrity, and confidentiality. This is included as a basic element of IPv6 and will be included in all implementations.
Page 62 of the GarrettCom MNS-6K user manual — Configuring IPv6
Page 62 · click to enlarge
Page 62

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

IPv6 Addressing

IPv6 addresses are 128-bits long and are identifiers for individual interfaces and sets of interfaces. IPv6 addresses of all types are assigned to interfaces, not nodes. Since each interface belongs to a single node, any of that node's interfaces' unicast addresses may be used as an identifier for the node. A single interface may be assigned multiple IPv6 addresses of any type.

There are three types of IPv6 addresses. These are unicast, anycast, and multicast. Unicast addresses identify a single interface. Anycast addresses identify a set of interfaces such that a packet sent to an anycast address will be delivered to one member of the set. Multicast addresses identify a group of interfaces, such that a packet sent to a multicast address is delivered to all of the interfaces in the group. There are no broadcast addresses in IPv6, their function being superseded by multicast addresses.

IPv6 supports addresses which are four times the number of bits as IPv4 addresses (128 vs. 32). This is 4 Billion times 4 Billion times 4 Billion (296) times the size of the IPv4 address space (232). This works out to be:

This is an extremely large address space. In a theoretical sense this is approximately 665,570,793,348,866,943,898,599 addresses per square meter of the surface of the planet Earth (assuming the earth surface is 511,263,971,197,990 square meters). In the most pessimistic estimate this would provide 1,564 addresses for each square meter of the surface of the planet Earth. The optimistic estimate would allow for 3,911,873,538,269,506,102 addresses for each square meter of the surface of the planet Earth. Approximately fifteen percent of the address space is initially allocated. The remaining 85% is reserved for future use.

The details on the addressing are covered by numerous articles on the WWW as well as other literature and are not covered here.

Configuring IPv6

The commands used for IPv6 are the same as those used for IPv4. Some of the commands will be discussed in more details later. The only exception is the ‘ping’ command where there is a special command for IPv6. That commands is ‘ping6’ and the syntax is as

Syntax ping6 <IPv6 address> - pings an IPv6 station

There is also a special command to ping the status of IPv6. That command is Syntax show ipv6 - displays the IPv6 information To configure IPv6, the following sequence of commands can be used.

340,282,366,920,938,463,463,374,607,431,768,211,456

Page 63 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 63 · click to enlarge
Page 63

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum 6K25# ipconfig ? ipconfig : Configures the system IP address, subnet mask and gateway Usage ipconfig [ip=] [mask=] [dgw=] Magnum 6K25# ipconfig ip=fe80::220:6ff:fe25:ed80 mask=ffff:ffff:ffff:ffff:: Action Parameter Missing. "add" assumed. IPv6 Parameters Set. Magnum 6K25# show ipv6 IPv6 Address : fe80::220:6ff:fe25:ed80 mask : ffff:ffff:ffff:ffff:: Magnum 6K25# show ipconfig IP Address : 192.168.5.5 Subnet Mask : 255.255.255.0 Gateway Address : 192.168.5.1 IPv6 Address : fe80::220:6ff:fe25:ed80 mask : ffff:ffff:ffff:ffff:: IPv6 Gateway : :: Magnum 6K25# FIGURE 42 – Configuring IPv6

In addition to the commands listed above, the commands which support IPv6 addressing are Syntax ftp <IPv6 address> - ftp to an IPv6 station

Example – ftp fe80::220:6ff:fe25:ed80 Syntax telnet <IPv6 address> - telnet to an IPv6 station

Example – telnet fe80::220:6ff:fe25:ed80

Besides, if the end station supports IPv6 addressing (as most Linux and Windows systems do), one can access the switch using the IPv6 addressing as shown in the example below

http://fe80::220:6ff:fe25:ed80

List of commands in this chapter

Syntax ipconfig [ip=<ip-address>] [mask=<subnet-mask>] [dgw=<gateway>]

[add|del] – configure and IPv6 address. The add/delete option can be used to add or delete IPv4/IPv6 addresses

Syntax show ipconfig – display the IP configuration information – including IPv6 address

Page 64 of the GarrettCom MNS-6K user manual — Assumptions
Page 64 · click to enlarge
Page 64

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax ping6 <IPv6 address> - pings an IPv6 station

Syntax show ipv6 - displays the IPv6 information

Syntax ftp <IPv6 address> - ftp to an IPv6 station

Syntax telnet <IPv6 address> - telnet to an IPv6 station

Page 65 of the GarrettCom MNS-6K user manual — Passwords
Page 65 · click to enlarge
Page 65

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E Chapter 5

5 – Access Considerations

Securing the switch access….

his section explains how the access to the GarrettCom Magnum MNS-6K can be secured. Further security considerations are also covered such as securing access by IP address or MAC address. T

Securing access j

It is assumed here that the user is familiar with issues concerning security as well as securing access for users and computers on a network. Secure access on a network can be provided by authenticating against an allowed MAC address as well as IP address.

Passwords

Magnum 6K family of switches comes with a factory default password for the manager as well as the operator account. Passwords can be changed from the user id by using the command ‘set password’ command.

Magnum6K25# set password Enter New Password :******* Confirm New Password :******* Password has been modified successfully Magnum6K25# FIGURE 43 – Changing password for a given account

Other details on managing users and the passwords are covered in Chapter 2, User Management.

Syntax set password · Example

Page 66 of the GarrettCom MNS-6K user manual — Configuring Port Security
Page 66 · click to enlarge
Page 66

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Port Security

The port security feature can be used to block computers from accessing the network by requiring the port to validate the MAC address against a known list of MAC addresses. This port security feature is provided on an Ethernet, Fast Ethernet, or Gigabit Ethernet port. In case of a security violation, the port can be configured to go into the disable mode or drop mode. The disable mode disables the port, not allowing any traffic to pass through. The drop mode allows the port to remain enabled during a security violation and drop only packets that are coming in from insecure hosts. This is useful when there are other network devices connected to the Magnum 6K family of switches. If there is an insecure access on the secondary device, the Magnum 6K family of switches allows the authorized users to continue to access the network; the unauthorized packets are dropped preventing access to the network.

j

Network security hinges on the ability to allow or deny access to network resources. The access control aspect of secure network services involves allowing or disallowing traffic based on information contained in packets, such as the IP address, MAC address, or other content. Planning for access is a key architecture and design consideration. For example, which ports are configured for port security? Normally rooms with public access e.g. lobby, conference rooms etc. should be configured with port security. Once that is decided, the next few decisions are – who are the authorized and unauthorized users? What action should be taken against authorized as well as unauthorized users? How are the users identified as authorized or unauthorized?

Configuring Port Security

Login as a level 2 user or as a manager to configure port security. Once logged in, get to the port-security configuration level to setup and configure port security. Syntax configure port-security Or Syntax port-security For example

Magnum6K25# configure port-security Magnum6K25(port-security)## FIGURE 44 – Port security configuration mode

Alternately, the following commands can also be used to enter the port-security configuration mode:

Network security

Page 67 of the GarrettCom MNS-6K user manual — F IGURE 45 – Port security configuration mode
Page 67 · click to enlarge
Page 67

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

F IGURE 45 – Port security configuration mode

From the port-security configuration mode, the switch can be configured to: 1) Auto-learn the MAC addresses 2) Specify individual MAC addresses to allow access to the network 3) Validate or change the settings

The commands for doing the above actions are: Syntax allow mac=<address|list|range> port=<num|list|range> Syntax learn port=<number-list> <enable|disable> Syntax show port-security Syntax action port=<num|list|range> <none|disable|drop> Syntax signal port=<num|list|range> <none|log|trap|logandtrap> Syntax ps <enable|disable> Syntax remove mac=<all|address|list|range> port=<num|list|range> Syntax signal port=<num|list|range> <none|log|trap|logandtrap> Where allow mac – configures the switch to setup allowed MAC addresses on specific ports learn port – configures the switch to learn the MAC addresses associated with specific port or a group of ports show port-security – shows the information on port security programmed or learnt action port – specifies the designated action to take in case of a non authorized access ps – port security – allows port security to be enable or disabled remove mac – removes specific or all MAC addresses from port security lookup signal port=<num|list|range> - observe list of specified ports and notify if there is a security breach on the list of port specified. The signal can be a log entry, a trap to the trap receiver specified as part of the SNMP commands (where is that specified) or both

Magnum6K25# port-security Magnum6K25(port-security)##

Page 68 of the GarrettCom MNS-6K user manual — Network security
Page 68 · click to enlarge
Page 68

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax clear <history|log [1..5 |informational |activity |critical |fatal |debug] |terminal |arp|portstats|addr] – clear command to clear various aspects of the MNS-6K information – most notably clear addr – clears the addresses learnt Let’s look at a few examples.

Magnum6K25(port-security)## allow mac=00:c1:00:7f:ec:00,00:60:b0:88:9e:00

port=18 FIGURE 46 – Port security – allowing specific MAC addresses on a specified port. (No spaces between specified MAC addresses)

Magnum6K25(port-security)## action port=9,10 none Magnum6K25(port-security)## learn port=9,10 enable FIGURE 47 – Port security - the port learns the MAC addresses. Note – a maximum of 200 MAC addresses can be learnt per port and a maximum of 500 per switch. Also, the ‘action’ on the port must be set to none before the port ‘learns’ the MAC address information.

Magnum6K25(port-security)## ps enable Port Security is already enabled Magnum6K25(port-security)## ps disable Port Security Disabled Magnum6K25(port-security)## ps enable

Port Security Enabled FIGURE 48 – Enabling and disabling port security

Magnum6K25(port-security)## show port-security PORT STATE SIGNAL ACTION LEARN COUNT MAC ADDRESS 9 ENABLE LOG NONE ENABLE 6 00:e0:29:2a:f1:bd 00:01:03:e2:27:89 00:07:50:ef:31:40 00:e0:29:22:15:85 00:03:47:ca:ac:45 00:30:48:70:71:23

Page 69 of the GarrettCom MNS-6K user manual — Network security
Page 69 · click to enlarge
Page 69

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

10 ENABLE NONE NONE DISABLE 0 Not Configured 11 ENABLE NONE NONE DISABLE 0 Not Configured 12 ENABLE NONE NONE DISABLE 0 Not Configured 13 ENABLE NONE NONE DISABLE 0 Not Configured 14 ENABLE NONE NONE DISABLE 0 Not Configured 15 ENABLE NONE NONE DISABLE 0 Not Configured 16 ENABLE NONE NONE DISABLE 0 Not Configured Magnum6K25(port-security)## FIGURE 49 – Viewing port security settings on a switch. On port 9, learning is enabled. This port has 6 stations connected to it with the MAC addresses as shown. Other ports have learning disabled and the MAC addresses are not configured on those ports

Magnum6K25(port-security)## learn port=11 enable Port Learning Enabled on selected port(s) Magnum6K25(port-security)## show port-security PORT STATE SIGNAL ACTION LEARN COUNT MAC ADDRESS 9 ENABLE LOG NONE ENABLE 6 00:e0:29:2a:f1:bd 00:01:03:e2:27:89 00:07:50:ef:31:40 00:e0:29:22:15:85 00:03:47:ca:ac:45 00:30:48:70:71:23 10 ENABLE NONE NONE DISABLE 0 Not Configured 11 ENABLE NONE NONE ENABLE 0 Not Configured 12 ENABLE NONE NONE DISABLE 0 Not Configured 13 ENABLE NONE NONE DISABLE 0 Not Configured 14 ENABLE NONE NONE DISABLE 0 Not Configured 15 ENABLE NONE NONE DISABLE 0 Not Configured 16 ENABLE NONE NONE DISABLE 0 Not Configured Magnum6K25(port-security)## FIGURE 50 – Enabling learning on a port. Note – after the learning is enabled, the port security can be queried to find the status of MAC addresses learnt. If there were machines connected to this port, the MAC address would be shown on port 11 as they are shown on port 9

Magnum6K25(port-security)## allow mac=00:c1:00:7f:ec:00 port=9,11,13

Specified MAC address(es) allowed on selected port(s) Magnum6K25(port-security)## show port-security port=9,11,13 PORT STATE SIGNAL ACTION LEARN COUNT MAC ADDRESS 9 ENABLE LOG NONE ENABLE 6 00:e0:29:2a:f1:bd

Page 70 of the GarrettCom MNS-6K user manual — Network security
Page 70 · click to enlarge
Page 70

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

00:01:03:e2:27:89 00:07:50:ef:31:40 00:e0:29:22:15:85 00:03:47:ca:ac:45 00:30:48:70:71:23 00:c1:00:7f:ec:00 11 ENABLE NONE NONE ENABLE 0 00:c1:00:7f:ec:00 13 ENABLE NONE NONE DISABLE 0 00:c1:00:7f:ec:00 FIGURE 51 – Allowing specific MAC address on specific ports. After the MAC address is specified, the port or specific ports or a range of ports can be queried as shown

Magnum6K25(port-security)## remove mac=00:c1:00:7f:ec:00 port=13 Specified MAC address(es) removed from selected port(s) Magnum6K25(port-security)## show port-security port=13

PORT STATE SIGNAL ACTION LEARN COUNT MAC ADDRESS 13 ENABLE LOG NONE ENABLE 0 Not Configured Magnum6K25(port-security)## FIGURE 52 – Removing a MAC address from port security

Magnum6K25(port-security)## signal port=11 logandtrap

Port security Signal type set to Log and Trap on selected port(s) FIGURE 53 – Setting the logging on a port

The figures listed above show the necessary commands to setup port security. The recommended steps to setup security are:

1) Set the MNS-6K software to allow port security commands (Use ‘port-security’ command) 2) Enable port security (Use ‘enable ps’ command) 3) Enable learning on the required ports (Use ‘learn port=11 enable’ command for port 11) 4) Verify learning is enables and MAC addresses are being learnt on required ports (Use ‘show port-security port=11’ command) 5) Save the port-security configuration (Use ‘save’ command) 6) Disable learning on required ports (Use ‘learn port=11,15 disable’ command) 7) (Optional step) Add any specific MAC addresses, if needed, to allow designated devices to access the network (Use ‘add mac=00:c1:00:7f:ec:00 port=11,15’ command)

Page 71 of the GarrettCom MNS-6K user manual — Network security
Page 71 · click to enlarge
Page 71

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

8. Disable access to the network for unauthorized devices (Use ‘action port=11 ’ depending on whether the port should be disabled or the packed dropped. Follow that with a ‘show port-security’ command to verify the setting) 9) (Optional step) Set the notification to notify the management station on security breach attempts (Use command ‘signal port’ to make a log entry or send a trap)

Port Security is already enabled Magnum6K25(port-security)## learn port=11 enable

Port Learning Enabled on selected port(s) Magnum6K25(port-security)## show port-security PORT STATE SIGNAL ACTION LEARN COUNT MAC ADDRESS 9 ENABLE LOG NONE ENABLE 6 00:e0:29:2a:f1:bd 00:01:03:e2:27:89 00:07:50:ef:31:40 00:e0:29:22:15:85 00:03:47:ca:ac:45 00:30:48:70:71:23 10 ENABLE NONE NONE DISABLE 0 Not Configured 11 ENABLE NONE NONE ENABLE 0 00:c1:00:7f:ec:00 12 ENABLE NONE NONE DISABLE 0 Not Configured 13 ENABLE NONE NONE DISABLE 0 Not Configured 14 ENABLE NONE NONE DISABLE 0 Not Configured 15 ENABLE NONE NONE DISABLE 0 Not Configured 16 ENABLE NONE NONE DISABLE 0 Not Configured Magnum6K25(port-security)## save

Saving current configuration Configuration saved Magnum6K25(port-security)## learn port=11 disable

Port Learning Disabled on selected port(s) Magnum6K25(port-security)## action port=11 drop Port security Action type set to Drop on selected port(s) Magnum6K25(port-security)## show port-security port=11 PORT STATE SIGNAL ACTION LEARN COUNT MAC ADDRESS 11 ENABLE NONE DROP DISABLE 0 00:c1:00:7f:ec:00 Magnum6K25(port-security)## signal port=11 logandtrap

Port security Signal type set to Log and Trap on selected port(s)

Magnum6K25# port-security · Magnum6K25(port-security)## ps enable · Magnum6K25(port-security)## exit

Page 72 of the GarrettCom MNS-6K user manual — Logs
Page 72 · click to enlarge
Page 72

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# FIGURE 54 – Steps for setting up port security on a specific port

Once port security is setup, it is important to manage the log and review the log often. If the signals are sent to the trap receiver, the traps should also be reviewed for intrusion and other infractions.

Logs

All events occurring on the Magnum 6K family of switches are logged. The events can be as shown below

Code Description 0 Emergency: system is unusable – called “fatal” in show log command 1 Alert: action must be taken immediately 2 Critical: critical conditions 3 Error: error conditions 4 Warning: warning conditions 5 Notice: normal but significant condition – called “note” in show log command 6 Informational: informational messages 7 Debug: debug-level messages

A few point to note about logs

  • By default, the logging is limited to the first six levels
  • The event log is now automatically saved to flash, so rebooting will not loose them. NOTE – since the event logs are written on the flash, once the flash memory is full, the logs stop writing. It is important to erase the log periodically or use syslog capability to download the logs to a syslog server
  • The event log now includes more information, because of the additional flexibility built into the log engine. For example, it now logs the IP address and user name of a remote user login
  • The log size parameter is now redefined as the max size of the log that is saved to flash. More events might appear in the log as they happen, but the whole list will be trimmed to the specified max size when a save command is issued, or the system rebooted. These logs are in compliance with the definitions of RFC 3164, though not all the nuances of the syslog are implemented as specified by the RFC.
Page 73 of the GarrettCom MNS-6K user manual — Network security
Page 73 · click to enlarge
Page 73

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

The ‘show log’ command displays the log information and the ‘clear log’ command clears the log entries. Syntax show log [fatal|alert|crit|error|warn|note|info|debug] – display the log Syntax clear log [fatal|alert|crit|error|warn|note|info|debug]– clear the log Syntax set logsize size=<1-1000> - set the number of line to be collected in the log before the oldest record is re-written

Magnum6K25# show log S Date Time Log Description -- Note 04-17-2007 09:57:27 P.M CLI:Session Timed Out for User manager on Telnet: Note 04-17-2007 09:57:27 P.M CLI:Session Term. User manager on Telnet: Note 04-17-2007 10:00:06 P.M CLI:Session Started from Telnet: 192.168.5.2 Note 04-17-2007 10:00:12 P.M CLI:User manager Login From Telnet: 192.168.5.2 Note 04-17-2007 10:08:58 P.M CLI:User manager Logout From Telnet: 192.168.5.2 Note 04-17-2007 10:08:58 P.M CLI:Session Term. User manager on Telnet: Note 01-01-2001 12:00:00 A.M SYSMGR:System Was Rebooted By power cycle Note 01-01-2001 12:00:00 A.M SNTP:System Clock Set to Default Note 01-01-2001 12:01:32 A.M WEB:Session Started from SWM: 192.168.5.2 Note 01-01-2001 12:01:47 A.M WEB:User manager Login From SWM: 192.168.5.2 Note 01-01-2001 12:04:16 A.M SYSMGR:Loaded Application Ver 3.7 Note 01-01-2001 12:00:00 A.M SYSMGR:System Was Rebooted By HW Watchdog Note 01-01-2001 12:00:00 A.M SNTP:System Clock Set to Default Note 01-01-2001 12:01:13 A.M WEB:Session Started from SWM: 192.168.5.2 Note 01-01-2001 12:01:25 A.M WEB:User manager Login From SWM: 192.168.5.2 Note 04-23-2007 09:57:01 A.M SNTP:System Time Zone Set to -08:00 Note 04-23-2007 05:59:02 P.M SNTP:SNTP Client Started Note 04-23-2007 05:59:09 P.M SNTP:SNTP Time Synchronized Note 04-23-2007 05:59:10 P.M SNTP:SNTP Time Synchronized Note 04-23-2007 05:59:36 P.M CLI:Session Started from Telnet: 192.168.5.2 Note 04-23-2007 05:59:39 P.M SNTP:SNTP Time Synchronized Note 04-23-2007 05:59:40 P.M SNTP:SNTP Time Synchronized Note 04-23-2007 05:59:49 P.M CLI:User manager Login From Telnet: 192.168.5.2 Note 04-23-2007 06:11:32 P.M CLI:Session Timed Out for User manager on Telnet: Note 04-23-2007 06:11:32 P.M CLI:Session Term. User manager on Telnet: Note 04-23-2007 06:18:05 P.M CLI:Session Started from Telnet: 192.168.5.2 Note 04-23-2007 06:18:16 P.M CLI:User manager Login From Telnet: 192.168.5.2 Magnum6K25# clear log Clear Logged Events? [ 'Y' or 'N'] Y Magnum6K25# show log Magnum6K25#

Page 74 of the GarrettCom MNS-6K user manual — Authorized managers
Page 74 · click to enlarge
Page 74

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

FIGURE 55 – Show log and clear log command. The show log command indicates the type of log activity in the S column

The log shows the most recent intrusion at the top of the listing. If the log is filled when the switch detects a new intrusion, the oldest entry is dropped off the listing.

As discussed in the prior section, any port can be set to monitor security as well as make a log on the intrusions that take place. The logs for the intrusions are stored on the switch. When the switch detects an intrusion on a port, it sets an “alert flag” for that port and makes the intrusion information available.

The default log size is 50 rows. To change the log size, use the “set logsize” command. When the switch detects an intrusion attempt on a port, it records the date and time stamp, the MAC address, the port on which the access was attempted and the action taken by MNS-6K software. The event log lists the most recently detected security violation attempts. This provides a chronological entry of all intrusions attempted on a specific port. The event log records events as single-line entries listed in chronological order, and serves as a tool for isolating problems. Each event log entry is composed of four fields Severity – the level of severity (see below) Date – date the event occurred on. See Chapter 3 on setting the date and time on the switch Time – time the event occurred on. See Chapter 3 on setting the date and time on the switch Log Description – description of event as detected by the switch Severity is one of 8 severities described at the beginning of this section.

Authorized managers

Just as port security allows and disallows specific MAC addresses from accessing a network, the MNS-6K software can allow or block specific IP addresses or a range of IP addresses to access the switch. The command used for that is

Syntax access – access configuration mode Syntax allow ip=<ipaddress> mask=<netmask> service=<name|list> - authorize

managers Syntax deny ip=<ipaddress> mask=<netmask> service=<name|list> - deny access

to a specific IP address(s) or a subnet

Page 75 of the GarrettCom MNS-6K user manual — Network security
Page 75 · click to enlarge
Page 75

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax remove ip=<ipaddress> mask=<netmask> - remove specific IP address(s) or

subnet Syntax removeall - remove all managers Syntax show ip-access – display list of authorized managers

access – context are the access commands

allow – allow specified services for specified IP addresses – IP addresses can be individual

stations, a group of stations or subnets. The range is determined by the IP address and netmask settings

deny – deny specified services for specified IP addresses – IP addresses can be individual

stations, a group of stations or subnets. The range is determined by the IP address and netmask settings

remove – eliminate specified entry from the authorized manager list

removeall – remove all authorized managers

service – the services allowed or denied are telnet, web and SNMP

It is assumed here that the user is familiar with IP addressing schemes (e.g. Class A, B, C etc.), subnet masking and masking issues such as how many stations are allowed for a given subnet mask.

In the examples – any computer on 192.168.5.0 network is allowed (note how the subnet mask is used to indicate that). Also a specific station with IP address 192.168.15.25 is allowed (again note how the subnet mask is used to allow only one specific station in the network.) Older station with IP address 192.168.15.15 is removed.

Magnum6K25# access Magnum6K25(access)## allow ip=192.168.5.0 mask=255.255.255.0 service=telnet Service(s) allowed for specified address Magnum6K25(access)## allow ip=192.168.15.25 mask=255.255.255.255 service=telnet Service(s) allowed for specified address Magnum6K25(access)## remove ip=192.168.15.15 mask=255.255.255.255 Access entry removed Magnum6K25(access)## exit

Page 76 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 76 · click to enlarge
Page 76

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# show ip-access ========================================================================== IP Address | Mask | Telnet | Web | SNMP | ========================================================================== 192.168.5.0 255.255.255.0 ALLOWED DENIED DENIED 192.168.15.25 255.255.255.255 ALLOWED DENIED DENIED

FIGURE 56 – Steps to allow deny or remove specific services

List of commands in this chapter

Syntax set password – set or change password

Syntax configure port-security – sets the port authorization based on MAC addresses

Syntax port-security – configure port security settings

Syntax allow mac=<address|list|range> port=<num|list|range> - specify a specific

MAC address or MAC address list

Syntax learn port=<number-list> <enable|disable> - learn MAC addresses connected to the

Syntax show port-security – display port security settings

Syntax action port=<num|list|range> <none|disable|drop> - action to perform in case of

breach of port security

Syntax signal port=<num|list|range> <none|log|trap|logandtrap> - port to monitor

and signal to send in case of breach of port security

Syntax ps <enable|disable> - enable or disable port security

Syntax remove mac=<all|address|list|range> port=<num|list|range> - remove a

Syntax show log [fatal|alert|crit|error|warn|note|info|debug] – display logs and

specific types of logs

Syntax clear log [fatal|alert|crit|error|warn|note|info|debug] – clear logs or specific

Syntax set logsize size=<1-1000> - set the log buffer size

Syntax access – setup access configuration parameters

Syntax allow ip=<ipaddress> mask=<netmask> service=<name|list> - allow specific

IP address or range of addresses as a trusted host(s)

Syntax deny ip=<ipaddress> mask=<netmask> service=<name|list> - deny specific

IP address or range of IP addresses

Syntax remove ip=<ipaddress> mask=<netmask> - delete a specific IP address from the

access or trusted host list

Magnum 6K switch · MAC address entry · type of logs

Page 77 of the GarrettCom MNS-6K user manual — Network security
Page 77 · click to enlarge
Page 77

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax removeall – remove all IP addresses of trusted hosts

Syntax show ip-access – display all trusted hosts

Syntax clear <history|log [1..5 |informational |activity |critical |fatal |debug]

|terminal |arp|portstats|addr] – clear command to clear various aspects of the MNS- 6K information – most notably “clear addr” – clears the addresses learnt or “clear log” to clear the logs (and the type of logs)

Page 78 of the GarrettCom MNS-6K user manual — j
Page 78 · click to enlarge
Page 78

Chapter 6

6 – Access Using RADIUS

Using a RADIUS server to authenticate access….

he IEEE 802.1x standard, Port Based Network Access Control, defines a mechanism for port- based network access control that makes use of the physical access characteristics of IEEE 802 LAN infrastructure. It provides a means of authenticating and authorizing devices attached to LAN ports that have point-to-point connection characteristics. It also prevents access to that port in cases where the authentication and authorization fails. Although 802.1x is mostly used in wireless networks, this protocol is also implemented in LANs. The Magnum 6K family of switches implements the authenticator, which is a major component of 802.1x. T

j

RADIUS Remote Authentication Dial-In User Service or RADIUS is a server that has been

traditionally used by many Internet Service Providers (ISP) as well as Enterprises to authenticate dial in users. Today, many businesses use the RADIUS server for authenticating users connecting into a network. For example, if a user connects a PC into the network, whether the PC should be allowed access or not provides the same issues as to whether or not a dial in user should be allowed access into the network or not. A user has to provide a user name and password for authenticated access. A RADIUS server is well suited for controlling access into a network by managing the users who can access the network on a RADIUS server. Interacting with the server and taking corrective action(s) is not possible on all switches. This capability is provided on the Magnum 6K family of switches.

RADIUS servers and its uses are also described by one or more RFCs.

There are three major components of 802.1x: - Supplicant, Authenticator and Authentication Server (RADIUS Server). In the figure below, the PC acts as the supplicant. The supplicant is an entity being authenticated and desiring access to the services. The switch is the authenticator. The authenticator enforces authentication before

Page 79 of the GarrettCom MNS-6K user manual — RADIUS
Page 79 · click to enlarge
Page 79

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

allowing access to services that are accessible via that port. The authenticator is responsible for communication with the supplicant and for submitting the information received from the supplicant to a suitable authentication server. This allows the verification of user credentials to determine the consequent port authorization state. It is important to note that the authenticator’s functionality is independent of the actual authentication method. It effectively acts as a pass-through for the authentication exchange.

802.1x Switch

802.1x Switch

FIGURE 57 – 802.1x network components

The RADIUS server is the authentication server. The authentication server provides a standard way of providing Authentication, Authorization, and Accounting services to a network. Extensible Authentication Protocol (EAP) is an authentication framework which supports multiple authentication methods. EAP typically runs directly over data link layers such as PPP or IEEE 802, without requiring IP. EAP over LAN (EAPOL) encapsulates EAP packets onto 802 frames with a few extensions to handle 802 characteristics. EAP over RADIUS encapsulates EAP packets onto RADIUS packets for relaying to RADIUS authentication servers.

The details of the 802.1x authentication are shown below

Show 6 more labels / short text on this page
Authenticator · Authenticator · Supplicant · Supplicant · Authentication Server (RADIUS) · Authentication Server (RADIUS)
Page 80 of the GarrettCom MNS-6K user manual — RADIUS
Page 80 · click to enlarge
Page 80

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

EAPOL EAP over RADIUS

EAPOL EAP over RADIUS

802.1x Switch

802.1x Switch

X Port Connected Access Blocked

X Port Connected Access Blocked

EAP Request Id Y

EAP Request Id Y

Z RADIUS Access Request [ RADIUS Access Challenge EAP Request \

Z RADIUS Access Request [ RADIUS Access Challenge EAP Request \

EAP Response ] ^RADIUS Access Request

EAP Response ] ^RADIUS Access Request

RADIUS Access Accept EAP Success ` _

RADIUS Access Accept EAP Success ` _

FIGURE 58 – 802.1x authentication details

1. The supplicant (laptop/host) is initially blocked from accessing the network. The supplicant wanting to access these services starts with an EAPOL-Start frame 2. The authenticator (Magnum 6K switch), upon receiving an EAPOL-start frame, sends a response with an EAP-Request/Identity frame back to the supplicant. This will inform the supplicant to provide its identity 3. The supplicant then sends back its own identification using an EAP-Response/Identity frame to the authenticator (Magnum 6K switch.) The authenticator then relays this to the authentication server by encapsulating the EAP frame on a RADIUS-Access-Request packet 4. The RADIUS server will then send the authenticator a RADIUS-Access-Challenge packet 5. The authenticator (Magnum 6K switch) will relay this challenge to the supplicant using an EAP-Request frame. This will request the supplicant to pass its credentials for authentication 6. The supplicant will send its credentials using an EAP-Response packet 7. The authenticator will relay using a RADIUS-Access-Request packet 8. If the supplicant’s credentials are valid, RADIUS-Access-Accept packet is sent to the authenticator 9. The authenticator will then relay this on as an EAP-Success and provides access to the network 10. If the supplicant does not have the necessary credentials, a RADIUS-Access-Deny packet is sent back and relayed to the supplicant as an EAP-Failure frame. The access to the network continues to be blocked

Access Allowed · Access Allowed

Page 81 of the GarrettCom MNS-6K user manual — Configuring 802.1x
Page 81 · click to enlarge
Page 81

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

The Magnum MNS-6K software implements the 802.1x authenticator. It fully conforms to the standards as described in IEEE 802.1x, implementing all the state machines needed for port- based authentication. The Magnum MNS-6K Software authenticator supports both EAPOL and EAP over RADIUS to communicate to a standard 802.1x supplicant and RADIUS authentication server. The Magnum MNS-6K software authenticator has the following characteristics:

  • Allows control on ports using STP-based hardware functions. EAPOL frames are Spanning Tree Protocol (STP) link Bridge PDUs (BPDU) with its own bridge multicast address.
  • Relays MD5 challenge (although not limited to) authentication protocol to RADIUS server
  • Limits the authentication of a single host per port
  • The Magnum 6K family of switches provides the IEEE 802.1x MIB for SNMP management

Configuring 802.1x

On enabling 802.1x ports, make sure the port which connects to the RADIUS servers needs to be manually authenticated. To authenticate the port, use the “setport” command. The CLI commands to configure and perform authentication with a RADIUS server are Syntax auth - configuration mode to configure the 802.1x parameters Syntax show auth <config|ports> - show the 802.1x configuration or port status Syntax authserver [ip=<ip-addr>] [udp=<num>] [secret=<string>] - define the RADIUS

server – use UDP socket number if the RADIUS authentication is on port other than 1812 Syntax auth <enable|disable> - enables or disables the 802.1x authenticator function on MNS-6K switch Syntax setport port=<num|list|range> [status=<enable|disable>]

[control=<auto|forceauth|forceunauth>] [initialize=<assert|deassert>] - setting the port characteristic for an 802.1x network Syntax backend port=<num|list|range> supptimeout=<1-240>] [servertimeout=<1-240>]

[maxreq=<1-10>] - configure parameters for EAP over RADIUS

port – [mandatory] – port(s) to be configured supptimeout – [optional] This is the timeout in seconds the authenticator waits for the supplicant to respond back. Default value is 30 seconds. Values can range from 1 to 240 seconds. servertimeout – [optional] This is the timeout in seconds the authenticator waits for the backend RADIUS server to respond back. The default value is 30 seconds. Values can range from 1 to 240 seconds.

Page 82 of the GarrettCom MNS-6K user manual — RADIUS
Page 82 · click to enlarge
Page 82

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

maxreq – [optional] The maximum number of times the authenticator will retransmit an EAP Request packet to the Supplicant before it times out the authentication session. Its default value is 2. It can be set to any integer value from 1 to 10. Syntax portaccess port=<num|list|range> [quiet=<0-65535>] [maxreauth=<0-10>]

[transmit=<1-65535>] - set port access parameters for authenticating PCs or supplicants

port – [mandatory] – ports to be configured quiet – [optional] This is the quiet period, the amount of time, in seconds, the supplicant is held after an authentication failure before the authenticator retries the supplicant for connection. The default value is 60 seconds. Values can range from 0 to 65535 seconds. maxreauth – [optional] The number of re-authentication attempts that are permitted before the port becomes unauthorized. Default value is 2. Values are integers and can range from 0 to 10. transmit – [optional] This is the transmit period, this is the time in seconds the authenticator waits to transmit another request for identification from the supplicant. Default value is 30. Values can be from 1 to 65535 seconds Syntax reauth port=<num|list|range> [status=<enable|disable>] [period=<10-86400>] -

set values on how the authenticator (Magnum 6K switch) does the re-authentication with the supplicant or PC

port – [mandatory] – ports to be configured status – [optional] This enables/disables re-authentication period – [optional] this is the re-authentication period in seconds. This is the time the authenticator waits before a re-authentication process will be done again to the supplicant. Default value is 3600 seconds (1 hour). Values can range from 10 to 86400 seconds. Syntax show-stats port=<num> - displays 802.1x related statistics Syntax trigger-reauth port=<num|list|range> - manually initiate a re-authentication of supplicant

Magnum6K25# show auth config 802.1X Authenticator Configuration ======================================== Status : Disabled RADIUS Authentication Server

Make sure there is no 802.1x or Radius server defined. Note only one RADIUS server can be defined for the whole network.

============================== IP Address : 0.0.0.0 UDP Port : 1812 Shared Secret : Magnum6K25# auth Magnum6K25(auth)## setport port=2 status=enable control=forceauth initialize=assert Successfully set port control parameter(s)

The RADIUS server is on port #2. This port is authenticated manually. If the RADIUS server is several hops away, it may be necessary to authenticate the interconnection ports. Note make sure this command is executed before auth enable command.

Page 83 of the GarrettCom MNS-6K user manual — RADIUS
Page 83 · click to enlarge
Page 83

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25(auth)## auth disable 802.1X Authenticator is disabled. Magnum6K25(auth)## authserver ip=192.168.1.239 secret=secret

This command is not necessary, however is shown for completeness in case there was a RADIUS server defined and a previously set authentication scheme

Successfully set RADIUS Authentication Server parameter(s) Magnum6K25(auth)##auth enable 802.1X Authenticator is enabled. Magnum6K25(auth)## show auth ports Port Status Control Initialize Current State ================================================================ 1 Enabled Auto Deasserted Authorized 2 Enabled ForcedAuth Asserted Unauthorized 3 Enabled Auto Deasserted Authorized 4 Enabled Auto Deasserted Unauthorized 5 Enabled Auto Deasserted Unauthorized 6 Enabled Auto Deasserted Unauthorized 7 Enabled Auto Deasserted Unauthorized 8 Enabled Auto Deasserted Unauthorized 9 Enabled Auto Deasserted Unauthorized 10 Enabled Auto Deasserted Unauthorized 11 Enabled Auto Deasserted Unauthorized 12 Enabled Auto Deasserted Unauthorized 13 Enabled Auto Deasserted Unauthorized 14 Enabled Auto Deasserted Unauthorized 15 Enabled Auto Deasserted Unauthorized 16 Enabled Auto Deasserted Unauthorized -- Port not available Magnum6K25(auth)## show auth config 802.1x Authenticator Configuration ======================================== Status : Enabled RADIUS Authentication Server ======================================== IP Address : 192.168.1.239 UDP Port : 1812 Shared Secret : secret Magnum6K25(auth)## backend port=2 supptimeout=45 servertimeout=60 maxreq=5 Successfully set backend server authentication parameter(s)

Port #2 is where RADIUS server is connected

Command included for completeness – validate the RADIUS server settings

Backend command is used for setting characteristics of the timeouts and number of requests before access is denied.

Enable the authentication

Page 84 of the GarrettCom MNS-6K user manual — RADIUS
Page 84 · click to enlarge
Page 84

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25(auth)## show-port backend Port Supp Timeout Server Timeout Max Request (sec) (sec) ================================================= 1 30 30 2 2 45 60 5 3 30 30 2 4 30 30 2 5 30 30 2 6 30 30 2 7 30 30 2 8 30 30 2 9 30 30 2 10 30 30 2 11 30 30 2 12 30 30 2 13 30 30 2 14 30 30 2 15 30 30 2 16 30 30 2 Magnum6K25(auth)## portaccess port=2 quiet=120 maxreauth=7 transmit=120 Successfully set port access parameter(s) Magnum6K25(auth)## show-port access Port Quiet Period Max Reauth Tx Period (sec) (sec) ================================================= 1 60 2 30 2 120 7 120 3 60 2 30 4 60 2 30 5 60 2 30 6 60 2 30 7 60 2 30 8 60 2 30 9 60 2 30 10 60 2 30 11 60 2 30 12 60 2 30 13 60 2 30 14 60 2 30 15 60 2 30 16 60 2 30 Magnum6K25(auth)## reauth port=1 status=enable period=300 Successfully set re-authentication parameter(s)

The authenticator waits for the supplicant to respond back for 45 seconds; the authenticator waits for 60 seconds for the backend RADIUS server to respond back and the authenticator will retransmit an EAP request packet 5 times to the Supplicant before it times out the authentication session

The amount of time, in seconds, the supplicant is held after an authentication failure before the authenticator retries the supplicant for connection is changed to 120 seconds, the number of re- authentication attempts that are permitted before the Port becomes Unauthorized is set to 7 and the time in seconds the authenticator waits to transmit another request for identification from the supplicant is changed to 120 seconds. These values can be changed on all ports depending on devices being authenticated.

Force the authentication period on port #1 every 5 minutes – all other ports are force authenticated every hour as the show- port reauth command shows.

Page 85 of the GarrettCom MNS-6K user manual — F IGURE 59 – securing the network using port access
Page 85 · click to enlarge
Page 85

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25(auth)## show-port reauth Port Reauth Status Reauth Period (sec) ================================================= 1 Enabled 300 2 Enabled 3600 3 Enabled 3600 4 Enabled 3600 5 Enabled 3600 6 Enabled 3600 7 Enabled 3600 8 Enabled 3600 9 Enabled 3600 10 Enabled 3600 11 Enabled 3600 12 Enabled 3600 13 Enabled 3600 14 Enabled 3600 15 Enabled 3600 16 Enabled 3600 Magnum6K25(auth)## show-stats port=3 Port 3 Authentication Counters

See Figure 47 for meaning of these statistics.

authEntersConnecting : 3 authEapLogoffsWhileConnecting : 0 authEntersAuthenticating : 3 authAuthSuccessesWhileAuthenticating : 2 authAuthTimeoutsWhileAuthenticating : 0 authAuthFailWhileAuthenticating : 0 authAuthReauthsWhileAuthenticating : 0 authAuthEapStartsWhileAuthenticating : 1 authAuthEapLogoffWhileAuthenticating : 0 authAuthReauthsWhileAuthenticated : 0 authAuthEapStartsWhileAuthenticated : 0 authAuthEapLogoffWhileAuthenticated : 0 backendResponses : 5 backendAccessChallenges : 2 backendOtherRequestsToSupplicant : 0 backendNonNakResponsesFromSupplicant : 2 backendAuthSuccesses : 2 backendAuthFails : 0

Force re-authentication on port #3.

F IGURE 59 – securing the network using port access

Magnum6K25(auth)## trigger-reauth port=3 · Successfully triggered re-authentication

Page 86 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 86 · click to enlarge
Page 86

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

List of commands in this chapter

Syntax auth - configuration mode to configure the 802.1x parameters Syntax show auth <config|ports> - show the 802.1x configuration or port status Syntax authserver [ip=<ip-addr>] [udp=<num>] [secret=<string>] - define the RADIUS

server – use UDP socket number if the RADIUS authentication is on port other than 1812 Syntax auth <enable|disable> - enables or disables the 802.1x authenticator function on MNS-6K switch Syntax setport port=<num|list|range> [status=<enable|disable>]

[control=<auto|forceauth|forceunauth>] [initialize=<assert|deassert>] - setting the port characteristic for an 802.1x network Syntax backend port=<num|list|range> supptimeout=<1-240>] [servertimeout=<1-240>]

[maxreq=<1-10>] - configure parameters for EAP over RADIUS

port – [mandatory] – port(s) to be configured supptimeout – [optional] This is the timeout in seconds the authenticator waits for the supplicant to respond back. Default value is 30 seconds. Values can range from 1 to 240 seconds. servertimeout – [optional] This is the timeout in seconds the authenticator waits for the backend RADIUS server to respond back. The default value is 30 seconds. Values can range from 1 to 240 seconds. maxreq – [optional] The maximum number of times the authenticator will retransmit an EAP Request packet to the Supplicant before it times out the authentication session. Its default value is 2. It can be set to any integer value from 1 to 10. Syntax portaccess port=<num|list|range> [quiet=<0-65535>] [maxreauth=<0-10>]

[transmit=<1-65535>] - set port access parameters for authenticating PCs or supplicants

port – [mandatory] – ports to be configured quiet – [optional] This is the quiet period, the amount of time, in seconds, the supplicant is held after an authentication failure before the authenticator retries the supplicant for connection. The default value is 60 seconds. Values can range from 0 to 65535 seconds. maxreauth – [optional] The number of re-authentication attempts that are permitted before the port becomes unauthorized. Default value is 2. Values are integers and can range from 0 to 10. transmit – [optional] This is the transmit period, this is the time in seconds the authenticator waits to transmit another request for identification from the supplicant. Default value is 30. Values can be from 1 to 65535 seconds

Page 87 of the GarrettCom MNS-6K user manual — RADIUS
Page 87 · click to enlarge
Page 87

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax reauth port=<num|list|range> [status=<enable|disable>] [period=<10-86400>] -

set values on how the authenticator (Magnum 6K switch) does the re-authentication with the supplicant or PC

port – [mandatory] – ports to be configured status – [optional] This enables/disables re-authentication period – [optional] this is the re-authentication period in seconds. This is the time the authenticator waits before a re-authentication process will be done again to the supplicant. Default value is 3600 seconds (1 hour). Values can range from 10 to 86400 seconds. Syntax show-stats port=<num> - displays 802.1x related statistics Syntax trigger-reauth port=<num|list|range> - manually initiate a re-authentication of supplicant

Page 88 of the GarrettCom MNS-6K user manual — j
Page 88 · click to enlarge
Page 88

Chapter 7

7 – Access Using TACACS+

Using a TACACS+ server to authenticate access….

ACACS+, short for Terminal Access Controller Access Control System, protocol provides access control for routers, network access servers and other networked computing devices via one or more centralized servers. TACACS+ provides separate authentication, authorization and accounting services. T

TACACS – flavors and history TACACS allows a client to accept a username and password and send a query to a TACACS authentication server, sometimes called a TACACS daemon (server) or simply TACACSD. This server was normally a program running on a host. The host would determine whether to accept or deny the request and sent a response back.

j

The TACACS+ protocol is the latest generation of TACACS. TACACS is a simple UDP based access control protocol originally developed by BBN for the MILNET (Military Network). Cisco’s enhancements to TACACS are called XTACACS. XTACACS is now replaced by TACACS+. TACACS+ is a TCP based access control protocol. TCP offers a reliable connection- oriented transport, while UDP offers best-effort delivery. TACACS+ improves on TACACS and XTACACS by separating the functions of authentication, authorization and accounting and by encrypting all traffic between the Network Access Server (NAS) and the TACACS+ clients or services or daemon. It allows for arbitrary length and content authentication exchanges, which allows any authentication mechanism to be utilized with TACACS+ clients. The protocol allows the TACACS+ client to request very fine- grained access control by responding to each component of a request. The Magnum 6K family of switches implements a TACACS+ client.

1. TACACS+ servers and daemons use TCP Port 49 for listening to client requests. Clients connect to this port number to send authentication and authorization packets. 2. There can be more than one TACACS+ server on the network. MNS6K supports a maximum of five TACACS+ servers
Page 89 of the GarrettCom MNS-6K user manual — TACACS+ Flow
Page 89 · click to enlarge
Page 89

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

TACACS+ Flow

TACACS works in conjunction with the local user list on the MNS-6K software (operating system.) Please refer to User Management for adding users on the MNS-6K software. The process of authentication as well as authorization is shown in the flow chart below.

User List? Yes Is User Manager?

User List? Yes Is User Manager?

TACACS+ Enabled? No Logout

TACACS+ Enabled? No Logout

Connect to TACACS server to

Connect to TACACS server to

Connect to TACACS server to

Operator or Authorization Failure Login as Operator

Operator or Authorization Failure Login as Operator

FIGURE 60 – Flow chart describing the interaction between local users and TACACS authorization

The above flow diagram shows the tight integration of TACACS+ authentication with the local user-based authentication. There are two stages a user goes through in TACACS+. The first stage

Show 50 more labels / short text on this page
Start · Start · Login as Operator · Login as Operator · Login · Login · No · No · User in Local · User in Local · Yes · Yes · No · No · Login as Manager · Login as Manager · Yes · Yes · Yes · Yes · Authentication failure · Authentication failure · Connection failure · Connection failure · Additional · Additional · Servers? Additional · Logout · Logout · Servers? · Servers? · authenticate · authenticate · authenticate · No · No · Authorized as · Authorized as · Authenticated · Authenticated · Logout · Logout · TACACS+ authorization · TACACS+ authorization · Authorized as · Authorized as · Manager · Manager · Login as Manager · Login as Manager
Page 90 of the GarrettCom MNS-6K user manual — Configuring TACACS+
Page 90 · click to enlarge
Page 90

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

is authentication where the user is verified against the network user database. The second stage is authorization, where it is determined whether the user has operator access or manager privileges.

TACACS+ Packet

Packet encryption is a supported and is a configurable option for the Magnum MNS-6K software. When encrypted, all authentication and authorization TACACS+ packets are encrypted and are not readable by protocol capture and sniffing devices such as EtherReal or others. Packet data is hashed and shared using MD5 and secret string defined between the Magnum 6K family of switches and the TACACS+ server.

4 4 8 8 8 bits

Packet type Sequence no. Flags

Length FIGURE 61 – TACACS packet format

  • Major Version – The major TACACS+ version number.
  • Minor version – The minor TACACS+ version number. This is intended to allow revisions to the TACACS+ protocol while maintaining backwards compatibility
  • Packet type – Possible values are
  • TAC_PLUS_AUTHEN:= 0x01 (Authentication) TAC_PLUS_AUTHOR:= 0x02 (Authorization) TAC_PLUS_ACCT:= 0x03 (Accounting)
  • Sequence number – The sequence number of the current packet for the current session
  • Flags – This field contains various flags in the form of bitmaps. The flag values signify whether the packet is encrypted
  • Session ID – The ID for this TACACS+ session
  • Length - The total length of the TACACS+ packet body (not including the header)

Configuring TACACS+

CLI commands to configure TACACS+ are

Show 4 more labels / short text on this page
32 bits wide · Major Version · Minor Version · Session ID
Page 91 of the GarrettCom MNS-6K user manual — TACACS – flavors and history
Page 91 · click to enlarge
Page 91

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax show tacplus <status|servers> - show status of TACACS or servers configured as TACACS+

servers Syntax tacplus <enable|disable> [ order=<tac,local | local,tac>] - enable or disable TACACS

authentication, specifying the order in which the server or local database is looked up where “tac,local” implies, first the TACAS+ server, then local logins on the device. Default order is Local then TACACS+ server. Syntax tacserver <add|delete> id=<num> [ip=<ip-addr>] [port=<tcp-port>]

[encrypt=<enable|disable>] [key=<string>] [mgrlevel=<level>] [oprlevel=<level>] – adds a list of up to five TACACS+ servers where <add|delete> – [mandatory] adds or delete a TACACS+ server. id=<num> – [mandatory] the order in which the TACACS+ servers should be polled for authenticaton [ip=<ip-addr>] – [mandatory for add] the IP address of the TACACS+ server [port=<tcp-port>] – [optional for add] TCP port number on which the server is listening [encrypt=<enable|disable>] – [optional for add] enable or disable packet encryption [key=<string>] – [optional for add, mandatory with encrypt] when encryption is enabled, the secret shared key string must be supplied [mgrlevel=<level>] and [oprlevel=<level>] – [optional] specifies the manager and operator level as defined on the TACACS+ server for the respective level of login

This command works in the user configuration mode as well. Note – maximum of five TACACS+ servers.

Magnum6K25# show tacplus servers ID TACACS+ Server Port Encrypt Key ================================================ 1 10.21.1.170 49 Enabled secret 2 -- 3 -- 4 -- 5 -- Magnum6K25# user Magnum6K25(user)## Magnum6K25(user)## show tacplus status

To configure TACACS+ enter the user configuration mode

Check the status of TACACS+ authentication. Note – this command was run in the user configuration mode.

TACACS+ StatusDisabled Magnum6K25(user)## tacplus disable

TACACS+ Tunneling is disabled. Magnum6K25(user)## tacserver add id=2 ip=10.21.1.123 encrypt=enable key=some

TACACS+ server is added. Magnum6K25(user)## show tacplus servers

Page 92 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 92 · click to enlarge
Page 92

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

ID TACACS+ Server Port Encrypt Key ================================================ 1 10.21.1.170 49 Enabled secret 2 10.21.1.123 49 Enabled some 3 -- 4 -- 5 -- Magnum6K25(user)## tacserver delete id=2

TACACS+ server is deleted. Magnum6K25(user)## show tacplus servers ID TACACS+ Server Port Encrypt Key ================================================ 1 10.21.1.170 49 Enabled secret 2 -- 3 -- 4 -- 5 -- Magnum6K25(user)## tacplus enable

TACACS+ is enabled. Magnum6K25(user)## FIGURE 62 – Configuring TACACS+

List of commands in this chapter

Syntax show tacplus <status|servers> - show status of TACACS or servers configured as TACACS+

servers Syntax tacplus <enable|disable> [ order=<tac,local | local,tac>] - enable or disable TACACS

authentication, specifying the order in which the server or local database is looked up where “tac,local” implies, first the TACAS+ server, then local logins on the device Syntax tacserver <add|delete> id=<num> [ip=<ip-addr>] [port=<tcp-port>]

[encrypt=<enable|disable>] [key=<string>] [mgrlevel=<level>] [oprlevel=<level>] – adds a list of up to five TACACS+ servers where <add|delete> – [mandatory] adds or delete a TACACS+ server. id=<num> – [mandatory] the order in which the TACACS+ servers should be polled for authenticaton [ip=<ip-addr>] – [mandatory for add] the IP address of the TACACS+ server

Page 93 of the GarrettCom MNS-6K user manual — TACACS – flavors and history
Page 93 · click to enlarge
Page 93

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

[port=<tcp-port>] – [optional for add] TCP port number on which the server is listening [encrypt=<enable|disable>] – [optional for add] enable or disable packet encryption [key=<string>] – [optional for add, mandatory with encrypt] when encryption is enabled, the secret shared key string must be supplied [mgrlevel=<level>] and [oprlevel=<level>] – [optional] specifies the manager and operator level as defined on the TACACS+ server for the respective level of login

Page 94 of the GarrettCom MNS-6K user manual — Port mirroring
Page 94 · click to enlarge
Page 94

Chapter 8

8 – Port Mirroring and Setup

Setup the ports for network speeds, performance as well as for monitoring….

his section explains how individual characteristics of a port on the GarrettCom Magnum 6K family of switches are setup. For monitoring a specific port, the traffic on a port can be mirrored on another port and viewed by protocol analyzers. Other setup includes automatically setting up broadcast storm prevention thresholds. T

Port monitoring and mirroring

j

An Ethernet switch sends traffic from one port to another port, unlike a hub or a shared network device, where the traffic is “broadcast” on each and every port. Capturing traffic for protocol analysis or intrusion analysis can be impossible on a switch unless all the traffic for a specific port is “reflected” on another port, typically a monitoring port. The Magnum 6K family of switches can be instructed to repeat the traffic from one port onto another port. This process - when traffic from one port is reflecting to another port - is called port mirroring. The monitoring port is also called a “sniffing” port. Port monitoring becomes critical for trouble shooting as well as for intrusion detection.

Port mirroring

Monitoring a specific port can be done by port mirroring. Mirroring traffic from one port to another port allows analysis of the traffic on that port. The set of commands for port mirroring are Syntax show port-mirror – displays the status of port mirroring Syntax port-mirror - enter the port mirror configuration mode Syntax setport monitor=<monitor port number> sniffer=<sniffer port number> - setup a prot mirrior port Syntax prtmr <enable|disable> - enable and disable port mirroring

Page 95 of the GarrettCom MNS-6K user manual — [duplex=<half|full>] [auto=<enable|disable>] [flow=<enable|disable>] [bp=<enable|disable>] [status=<enable|disable>]
Page 95 · click to enlarge
Page 95

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

The set of commands show how port 11 is mirrored on port 13. Any traffic on port 11 is also sent on port 13.

Magnum6K25# show port-mirror Sniffer Port : 0 Monitor Port : 0 Mirroring State : disabled Magnum6K25# port-mirror Magnum6K25(port-mirror)## setport monitor=11 sniffer=13 Port 11 set as Monitor Port Port 13 set as Sniffer Port Magnum6K25(port-mirror)## prtmr enable Port Mirroring Enabled Magnum6K25(port-mirror)## exit Magnum6K25# show port-mirror Sniffer Port : 13 Monitor Port : 11 Mirroring State : enabled Magnum6K25# FIGURE 63 – Enabling port mirroring

Once port monitoring is completed, for security reasons, GarrettCom strongly recommends that the port mirroring be disabled using the “prtmr diable” command.

1. Only one port can be set to port mirror at a time 2) Both the ports (monitored port and sniffer port) have to belong to the same VLAN 3) The mirrored port shows both incoming as well as outgoing traffic 4) When port mirror is active, to change mirrored port, first disable port mirror and then assign the new port as described above

Port setup

Each port on the GarrettCom Magnum 6K family of switches can be setup specific port characteristics. The command for setting the port characteristics are: Syntax device – enter the device configuration mode Syntax setport port=<port#|list|range> [name=<name>] [speed=<10|100>]

[duplex=<half|full>] [auto=<enable|disable>] [flow=<enable|disable>] [bp=<enable|disable>] [status=<enable|disable>]

where device – sets up the Magnum 6K switch in the device configuration mode name – assigns a specific name to the port. This name is a designated name for the port and can be a server name, user name or any other name

Page 96 of the GarrettCom MNS-6K user manual — Speed settings
Page 96 · click to enlarge
Page 96

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

speed – specifically sets the speed to be 10 or 100Mbps. Note – this works only with 10/100 ports – with 10Mbps ports, the option is ignored. No error is shown. See speed settings section below. flow – sets up flow control on the port. See Flow Control section below bp – back pressure – enables back pressure signaling for traffic congestion management status – disable – disables the port from operation Syntax show port[=<port number>] In the example listed below, the ports 11 and 12 are given specific names. Ports 9 and 13 are active, as shown by the link status. Port 13 is set to 100 Mbps – all other ports are set to 10Mbps. All ports are set with auto sensing (speed)

Magnum6K25# device Magnum6K25(device)## setport port=11 name=JohnDoe Magnum6K25(device)## setport port=12 name=JaneDoe Magnum6K25(device)## show port Keys: E = Enable D = Disable H = Half Duplex F = Full Duplex M = Multiple VLANs NA = Not Applicable LI = Listening LE = Learning F = Forwarding B = Blocking Port Name Control Dplx Media Link Speed Part Auto VlanID GVRP STP 9 B1 E H 10Tx UP 10 No E 1 - - 10 B2 E H 10Tx DOWN 10 No E 1 - - 11 JohnDoe E H 10Tx DOWN 10 No E 1 - - 12 JaneDoe E H 10Tx DOWN 10 No E 1 - - 13 B5 E F 100Tx UP 100 No E 1 - - 14 B6 E H 10Tx DOWN 10 No E 1 - - 15 B7 E H 10Tx DOWN 10 No E 1 - - 16 B8 E H 10Tx DOWN 10 No E 1 - - Magnum6K25(device)## exit Magnum6K25# FIGURE 64 – Port setup

The port’s speed and duplex (data transfer operation) setting are summarized below. Speed settings Auto (default) – Senses speed and negotiates with the port at the other end of the link for data transfer operation (half-duplex or full-duplex). “Auto” uses the IEEE 802.3u auto negotiation standard for 100Base-T networks. If the other device does not comply

Page 97 of the GarrettCom MNS-6K user manual — Flow Control
Page 97 · click to enlarge
Page 97

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

with the 802.3u standard, then the port configuration on the switch must be manually set to match the port configuration on the other device. Possible port setting combinations for copper ports are:

  • 10HDx: 10 Mbps, Half-Duplex
  • 10FDx: 10 Mbps, Full-Duplex
  • 100HDx: 100 Mbps, Half-Duplex
  • 100FDx: 100 Mbps, Full-Duplex Possible port settings for 100FX (fiber) ports are:
  • 100FDx (default): 100 Mbps, Full-Duplex
  • 100HDx: 100 Mbps, Half-Duplex Possible port settings for 10FL (fiber) ports are:
  • 10HDx (default): 10 Mbps, Half-Duplex
  • 10FDx: 10 Mbps, Full-Duplex

Gigabit fiber-optic ports (Gigabit-SX and Gigabit-LX):

  • 1000FDx (default): 1000 Mbps (1 GBPS), Full Duplex only
  • Auto : The port operates at 1000FDx and auto-negotiates flow control with the device connected to the port Flow Control

Flow control is for full duplex operation and the controls provided indicates the number of buffers allowed for incoming traffic before a Rxon or Rxoff information is sent. RXon is sent when the number of buffers used by the traffic falls below the specified level (default is 4). Rxoff is sent when the number of buffers used goes above the specified value (default is 6). The "flowcontrol" command is used to set the above thresholds. It DOES NOT enable or DISABLE flow control Disabled (default) – The port will not generate flow control packets and drops received flow control packets Enabled: The port uses 802.3x Link Layer Flow Control, generates flow control packets, and processes received flow control packets.

With the port speed set to auto (the default) and flow control set to enabled; the switch negotiates flow control on the indicated port. If the port speed is not set to auto, or if flow control is disabled on the port, then flow control is not used. To set flow control Syntax flowcontrol xonlimit=<value> xofflimit=<value>

Page 98 of the GarrettCom MNS-6K user manual — Back Pressure
Page 98 · click to enlarge
Page 98

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

where xonlimit can be from 3 to 30, default value is 4 xofflimit from 3 to 127, default value is 6 Syntax show flowcontrol

Back Pressure Back Pressure is for half duplex operations and the controls provided indicates the number of buffers allowed for incoming traffic before a xon/xoff message is sent. Disabled (default) – The port will not use back pressure based flow control mechanisms. Enabled – The port uses 802.3 Layer 2 back off algorithms. Back pressure based congestion control is possible only on half-duplex, 10-Mbps Ethernet ports. Other technologies are not supported on Magnum 6K family of switches. Syntax backpressure rxthreshold=<value>

where rxthreshold value can be from 3 to 127, default is 28 Syntax show backpressure

Backpressure and Flow control are to be used in networks in which all devices and switches can participate in the flow control and back pressure recognition. In most networks, these techniques are not used as not all devices can participate in the flow control methods and notifications. Alternately, QoS and other techniques are widely used today.

In the example below, the Magnum 6K family of switches are setup with flow control and back pressure.

Page 99 of the GarrettCom MNS-6K user manual — Back Pressure
Page 99 · click to enlarge
Page 99

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# device Magnum6K25(device)## show flowcontrol XOnLimit : 4 XOffLimit : 6 Magnum6K25(device)## flowcontrol xonlimit=10 xofflimit=15 XOn Limit set successfully XOff Limit set successfully Magnum6K25(device)## show flowcontrol XOnLimit : 10 XOffLimit : 15 Magnum6K25(device)## show backpressure Rx Buffer Threshold : 28 Magnum6K25(device)## backpressure rxthreshold=45 Rx Buffer Threshold set successfully Magnum6K25(device)## show backpressure Rx Buffer Threshold : 45 Magnum6K25(device)## show port Keys: E = Enable D = Disable H = Half Duplex F = Full Duplex M = Multiple VLAN's NA = Not Applicable LI = Listening LE = Learning F = Forwarding B = Blocking Port Name Control Dplx Media Link Speed Part Auto VlanID GVRP STP 9 B1 E H 10Tx UP 10 No E 1 - - 10 B2 E H 10Tx DOWN 10 No E 1 - - 11 JohnDoe E H 10Tx DOWN 10 No E 1 - - 12 JaneDoe E H 10Tx DOWN 10 No E 1 - - 13 B5 E F 100Tx UP 100 No E 1 - - 14 B6 E H 10Tx DOWN 10 No E 1 - - 15 B7 E H 10Tx DOWN 10 No E 1 - - 16 B8 E H 10Tx DOWN 10 No E 1 - - Magnum6K25(device)## show port=11 Configuration details of port 11 Port Name : JohnDoe Port Link State : DOWN Port Type : TP Port Port Admin State : Enable Port VLAN ID : 1 Port Speed : 10Mbps Port Duplex Mode : half-duplex Port Auto-negotiation State : Enable Port STP State : NO STP Port GVRP State : No GVRP Port Priority Type : None Port Security : Enable

Page 100 of the GarrettCom MNS-6K user manual — j
Page 100 · click to enlarge
Page 100

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Port Flow Control : Disable Port Back Pressure : Disable Magnum6K25(device)## setport port=11 flow=enable bp=enable Magnum6K25(device)## show port Keys: E = Enable D = Disable H = Half Duplex F = Full Duplex M = Multiple VLAN's NA = Not Applicable LI = Listening LE = Learning F = Forwarding B = Blocking Port Name Control Dplx Media Link Speed Part Auto VlanID GVRP STP 9 B1 E H 10Tx UP 10 No E 1 - - 10 B2 E H 10Tx DOWN 10 No E 1 - - 11 JohnDoe E H 10Tx DOWN 10 No E 1 - - 12 JaneDoe E H 10Tx DOWN 10 No E 1 - - 13 B5 E F 100Tx UP 100 No E 1 - - 14 B6 E H 10Tx DOWN 10 No E 1 - - 15 B7 E H 10Tx DOWN 10 No E 1 - - 16 B8 E H 10Tx DOWN 10 No E 1 - - Magnum6K25(device)## show port=11 Configuration details of port 11 Port Name : JohnDoe Port Link State : DOWN Port Type : TP Port Port Admin State : Enable Port VLAN ID : 1 Port Speed : 10Mbps Port Duplex Mode : half-duplex Port Auto-negotiation State : Enable Port STP State : NO STP Port GVRP State : No GVRP Port Priority Type : None Port Security : Enable Port Flow Control : Enable Port Back Pressure : Enable Magnum6K25(device)## exit

Magnum6K25# FIGURE 65 – Setting up back pressure and flow control on ports

j

One of the best features of the Magnum 6K family of switches is its ability to keep broadcast storms from spreading throughout a network. Network storms (or broadcast storms) are characterized by an excessive number of broadcast packets being sent over the network. These storms can occur if network equipment is configured incorrectly or the network software is not properly functioning or badly designed programs (including some network games) are used. Storms can reduce network performance and cause bridges, routers, workstations, servers and PC's to slow down or even crash.

Broadcast Storms

Page 101 of the GarrettCom MNS-6K user manual — Preventing broadcast storms
Page 101 · click to enlarge
Page 101

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Preventing broadcast storms

The Magnum 6K family of switches is capable of detecting and limiting storms on each port. A network administrator can also set the maximum rate of broadcast packets (frames) that are permitted from a particular interface. If the maximum number is exceeded, a storm condition is declared. Once it is determined that a storm is occurring on an interface, any additional broadcast packets received on that interface will be dropped until the storm is determined to be over. The storm is determined to be over when a one- second period elapses with no broadcast packets received.

Syntax broadcast-protect <enable|disable> - enable or disable the broadcast storm protection

capabilities Syntax rate-threshold port=<port|list|range> rate=<frames/sec> - set the rate limit in frames per second Syntax show broadcast-protect – display the broadcast storm protection settings

In the example below, the broadcast protection is turned on. The threshold for port 11 is then set to a lower value of 3500 broadcast frames/second.

Magnum6K25# device Magnum6K25(device)## show broadcast-protect ====================================================================== PORT | STATUS | THRESHOLD (frms/sec) | CURR RATE (frms/sec) | ACTIVE ====================================================================== 9 Disabled 19531 0 NO 10 Disabled 19531 0 NO 11 Disabled 19531 0 NO 12 Disabled 19531 0 NO 13 Disabled 19531 0 NO 14 Disabled 19531 0 NO 15 Disabled 19531 0 NO 16 Disabled 19531 0 NO Magnum6K25(device)## broadcast-protect enable

Broadcast Storm Protection enabled Magnum6K25(device)## show broadcast-protect ====================================================================== PORT | STATUS | THRESHOLD (frms/sec) | CURR RATE (frms/sec) | ACTIVE ====================================================================== 9 Enabled 19531 0 NO 10 Enabled 19531 0 NO 11 Enabled 19531 0 NO 12 Enabled 19531 0 NO 13 Enabled 19531 0 NO 14 Enabled 19531 0 NO 15 Enabled 19531 0 NO

Page 102 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 102 · click to enlarge
Page 102

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

16 Enabled 19531 0 NO Magnum6K25(device)## rate-threshold port=11 rate=3500 Broadcast Rate Threshold set Magnum6K25(device)## show broadcast-protect ====================================================================== PORT | STATUS | THRESHOLD (frms/sec) | CURR RATE (frms/sec) | ACTIVE ====================================================================== 9 Enabled 19531 0 NO 10 Enabled 19531 0 NO 11 Enabled 3500 0 NO 12 Enabled 19531 0 NO 13 Enabled 19531 0 NO 14 Enabled 19531 0 NO 15 Enabled 19531 0 NO 16 Enabled 19531 0 NO FIGURE 66 – Setting up broadcast storm protection. Also shows how the threshold can be lowered for a specific port

Port Rate limiting for broadcast traffic

Please refer to the above section on broadcast storms.

List of commands in this chapter

Syntax show port-mirror – display port mirror settings Syntax port-mirror <enter> - configure port mirror settings Syntax setport monitor=<monitor port number> sniffer=<sniffer port number> - set port

mirror settings Syntax prtmr <enable|disable> - enable or disable port mirror settings Syntax device – configure device and port specific settings Syntax setport port=<port#|list|range> [name=<name>] [speed=<10|100>]

[duplex=<half|full>] [auto=<enable|disable>] [flow=<enable|disable>] [bp=<enable|disable>] [status=<enable|disable>] – configure port settings Syntax show port[=<Port number>] – display port settings Syntax flowcontrol xonlimit=<value> xofflimit=<value> - configure flow control buffers

Page 103 of the GarrettCom MNS-6K user manual — Broadcast Storms
Page 103 · click to enlarge
Page 103

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax show flowcontrol – display flow control buffers Syntax backpressure rxthreshold=<value> - configure backpressure buffers Syntax show backpressure – display backpressure buffers Syntax broadcast-protect <enable|disable> - protect switch from broadcast storms Syntax rate-threshold port=<port|list|range> rate=<frames/sec> - change the allowed broadcast

rate threshold

Page 104 of the GarrettCom MNS-6K user manual — VLAN 1 VLAN 2
Page 104 · click to enlarge
Page 104

Chapter 9

9 – VLAN

Create separate network segments (collision domains) across Magnum 6K family of switches…..

S

hort for virtual LAN (VLAN), a VLAN creates separate collision domains or network segments that can span multiple Magnum 6K family of switches. A VLAN is a group of ports designated by the switch as belonging to the same broadcast domain. The IEEE 802.1Q specification establishes a standard method for inserting VLAN membership information into

Ethernet frames.

j

VLAN’s provide the capability of having two (or more) Ethernet segments co-exist on common hardware. The reason for creating multiple segments in Ethernet is to isolate collision domains. VLANs can isolate groups of users, or divide up traffic for security, bandwidth management, etc. VLANs are widely used today and are here to stay. VLANs need not be in one physical location. They can be spread across geography or topology. VLAN membership information can be propagated across multiple Magnum6K switches.

Segment 1 Segment 2

Segment 1 Segment 1 Segment 2 Segment 2

VLAN 1 VLAN 2

VLAN 1 VLAN 1 VLAN 2 VLAN 2

GarrettCom MNS-6K — VLAN 1 VLAN 2 diagram (page 104)
Fig. 7

FIGURE 67 – VLAN as two separate collision domains. The top part of the figure shows two “traditional” Ethernet segments. Up to 32 VLANs can be defined per switch.

Why VLANs?

Page 105 of the GarrettCom MNS-6K user manual — VLAN 1 VLAN 1 VLAN 2 VLAN 2
Page 105 · click to enlarge
Page 105

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

A group of network users (ports) assigned to a VLAN form a broadcast domain. Packets are forwarded only between ports that are designated for the same VLAN. Cross-domain broadcast traffic in the switch is eliminated and bandwidth is saved by not allowing packets to flood out on all ports. For many reasons a port may be configured to belong to multiple VLANs.

Segment 1 Segment 1 Segment 2 Segment 2

Segment 3 Segment 3

VLAN 1 VLAN 1 VLAN 2 VLAN 2

VLAN 3 VLAN 3

GarrettCom MNS-6K — VLAN 1 VLAN 1 VLAN 2 VLAN 2 diagram (page 105)
Fig. 8

FIGURE 68 – Ports can belong to multiple VLANs. In this figure a simplistic view is presented where some ports belong to VLANs 1, 2 and other ports belong to VLANs 2,3. Ports can belong to VLANs 1, 2 and 3. This is not shown in the figure.

By default, on Magnum 6K family of switches, VLAN support is enabled and all ports on the switch belong to the default VLAN (DEFAULT-VLAN). This places all ports on the switch into one physical broadcast domain. If VLANs are entirely separate segments or traffic domains – how can the VLANs route traffic (or “talk”) to each other? This can be done using routing technologies (e.g., a router or a L3-switch). The routing function can be done internally to a L3-switch. One advantage of an L3 switch is that the switch can also support multiple VLANs. The L3 switch can thus route traffic across multiple VLANs easily and provides a cost effective solution if there are mnay VLANs defined.

Page 106 of the GarrettCom MNS-6K user manual — Tag VLAN or Port VLAN?
Page 106 · click to enlarge
Page 106

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Segment 1 Segment 1 Segment 2 Segment 2

Router

Router or L3-switch

VLAN 1 VLAN 1 VLAN 2 VLAN 2

GarrettCom MNS-6K — Segment 1 Segment 1 Segment 2 Segment 2 diagram (page 106)
Fig. 9 · Segment 1 Segment 1 Segment 2 Segment 2

FIGURE 69 – routing between different VLANs is performed using a router or a Layer 3 switch (L3- switch)

The Magnum 6K family of switches supports up to 32 VLANs per switch

Tag VLAN or Port VLAN?

What is the difference between tag and port VLAN? In a nutshell – the term port vlan is specific to a switch and port VLAN assigns a specific port or group of ports belonging to a VLAN. So when ports belong to multiple VLANs and they are specific to a switch, use the Port VLAN to configure that. Port VLANs do not look for VLAN identifier (VID) information nor does it manipulate the VID information. It thus works “transparently” and propagates the VLAN information along.

Page 107 of the GarrettCom MNS-6K user manual — Private VLANs
Page 107 · click to enlarge
Page 107

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

In the tag VLAN, an identifier called the VLAN identifier (VID) is either inserted or manipulated. This manipulated VLAN tag allows VLAN information to be propagated across devices or switches, allowing VLAN information to span multiple switches. As described earlier, VLAN is an administratively configured LAN or broadcast domain. Instead of going to the wiring closet to move a cable to a different LAN segment, the same task can be accomplished remotely by configuring a port on an 802.1Q-compliant switch to belong to a different VLAN. The ability to move end stations to different broadcast domains by setting membership profiles for each port on centrally managed switches is one of the main advantages of 802.1Q VLANs. 802.1Q VLANs aren't limited to one switch. VLANs can span many switches. Sharing VLANs between switches is achieved by inserting a tag with a VLAN identifier (VID) into each frame. A VID must be assigned for each VLAN. By assigning the same VID to VLANs on many switches, one or more VLAN (broadcast domain) can be extended across a large network. 802.1Q-compliant switch ports, such as those on the Magnum 6K family of switches, can be configured to transmit tagged or untagged frames. A tag field containing VLAN information can be inserted into an Ethernet frame. If a port has an 802.1Q-compliant device attached (such as another switch), these tagged frames can carry VLAN membership information between switches, thus letting a VLAN span multiple switches. Normally connections between switches can carry multiple VLAN information and this is call port trunking or 802.1Q trunks. There is one important caveat: administrators must ensure ports with non-802.1Q-compliant devices attached are configured to transmit untagged frames. Many network interface cards such as those for PCs printers and other “dumb” switches are not 802.1Q-compliant. If they receive a tagged frame, they will not understand the VLAN tag and will drop the frame. In situations like these, its best to use port based VLANs for connecting to these devices. Sometimes a port may want to listen to broadcasts across different VLANs or propagate the VLAN information on to other ports. This port must thus belong to multiple VLANs so that the broadcast information reaches the port accurately. If the port also wants to send broadcast traffic, the proper egress (sending out of information) and ingress (receiving information) has to be configured on the Magnum 6K family of switches. In Tag based VLAN this is similar but only if the port is tagged for each VLAN.

Private VLANs

Private VLANs are VLANs which are private to a given switch in a network. For Magnum 6K family of switches, the Private VLANs are usually restricted to a single switch. Private VLANs are implemented on Magnum 6K family of switches using Port based VLAN. See the section on Port VLAN for additional information.

Page 108 of the GarrettCom MNS-6K user manual — Creating VLANs
Page 108 · click to enlarge
Page 108

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

The reasons Private VLANs are constructed are for security. For example, if some confidential data were residing on VLAN 5, then only the people connected to that switch on VLAN 5 can have access to that information. No one else can access that VLAN. Similarly, if another switch had video surveillance equipment on VLAN 20 then only ports with access to VLAN 20 can have access to the video surveillance information. Finally, one port can belong to multiple VLANs – so depending on the function and use, different VLANs information can be shared across a port. Such a port is said to be in promiscuous mode for private VLANs.

Using Port VLANs

Port VLANs are rarely used in networks which uses the same VLANs across multiple switches. Port VLANs are used when VLANs are setup up on a single switch and connectivity between the system on different VLANs is needed. Broadcast traffic is not isolated to one VLAN in Port VLANs. General steps for using port VLANs are

1) Plan your VLAN strategy and create a map of the logical topology that will result from configuring VLANs. Include consideration for the interaction between VLANs. 2) Configure at least one VLAN in addition to the default VLAN 3) Assign the desired ports to the VLANs 4) Decide on trunking strategy – how will the VLAN information be propagated from one switch to another and also what VLAN information will be propagated across 5) (Layer 3 consideration) check to see if the routing between the VLANs is “working” by pinging stations on different VLANs

1. You can rename the default VLAN, but you cannot change its VID (1) or delete it from the switch 2) Any ports not specifically assigned to another VLAN will remain assigned to the DEFAULT-VLAN 3) Changing the number of VLANs supported on the switch requires the SAVE command to save the new VLAN information

Creating VLANs

Creating VLAN and to configure VLAN related commands Syntax set vlan type=<port|tag|none>

Page 109 of the GarrettCom MNS-6K user manual — [<mgt|nomgt>] Displaying the VLAN information Syntax show vlan type=<port|tag> [<id=vlanid>]
Page 109 · click to enlarge
Page 109

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

VLAN Configuration Syntax configure vlan type=port OR Syntax vlan type=port Adding VLANs

Syntax add id=<vlan Id> [name=<vlan name>] port=<number|list|range>

[forbid=<number|list|range>] [<mgt|nomgt>] Disabling Management on VLAN Use the option when creating a VLAN as shown in the add command above. Starting VLANs Syntax start vlan=<name|number|list|range> Saving the configuration

Syntax save Editing VLANs Syntax edit id=<vlan Id> [name=<vlan name>] port=<number|list|range>

[<mgt|nomgt>] Displaying the VLAN information Syntax show vlan type=<port|tag> [<id=vlanid>]

Magnum6K25#vlan type=port Magnum6K25(port-vlan)## add id=2 name=test port=1-10 Magnum6K25(port-vlan)## start vlan=all Magnum6K25(port-vlan)## save Saving current configuration... Configuration saved FIGURE 70 – configuring VLANs on Magnum 6K switch

The example below shows how to add three different VLANs. Along with the VLANs, Port 14 is assigned to the four VLANs – the three new ones added plus the DEFAULT-VLAN 1. The following

Page 110 of the GarrettCom MNS-6K user manual — Why VLANs?
Page 110 · click to enlarge
Page 110

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

interaction shows how VLANs 10, 20, 30 are added to port 14 and the VLANs activated. A typical use for such a port would be to connect a “dumb” switch to this port and allow traffic from three different VLANs to pass through transparently to the “dumb” switch, which will be connected to port 14. Note in this example, VLAN information is not propagated on to the “dumb” switch.

Magnum6K25# set vlan type=port VLAN set to Port-based. Magnum6K25# vlan type=port Magnum6K25(port-vlan)## add id=10 name=engineering port=14 Vlan added successfully with Vlan id : 10 Vlan name : engineering Ports : 14 Magnum6K25(port-vlan)## add id=20 name=engineering port=14 ERROR - Duplicate Vlan name Magnum6K25(port-vlan)## add id=20 name=sales port=14 Vlan added successfully with Vlan id : 20 Vlan name : sales Ports : 14 Magnum6K25(port-vlan)## add id=30 name=marketing port=14 Vlan added successfully with Vlan id : 30 Vlan name : marketing Ports : 14 Magnum6K25(port-vlan)## show vlan type=port VLAN ID : 1 Name : Default VLAN Status : Active ======================== PORT | STATUS ======================== 9 | UP 10 | DOWN 11 | DOWN 12 | DOWN 13 | UP 14 | DOWN 15 | DOWN 16 | DOWN

Enter the VLAN configuration mode

Page 111 of the GarrettCom MNS-6K user manual — Why VLANs?
Page 111 · click to enlarge
Page 111

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

VLAN ID : 10 Name : engineering Status : Pending ======================== PORT | STATUS ======================== 14 | DOWN VLAN ID : 20 Name : sales Status : Pending ======================== PORT | STATUS ======================== 14 | DOWN VLAN ID : 30 Name : marketing Status : Pending ======================== PORT | STATUS ======================== 14 | DOWN Magnum6K25(port-vlan)##start vlan=all All pending VLAN's started. Magnum6K25(port-vlan)##show vlan type=port VLAN ID : 1 Name : Default VLAN Status : Active ======================== PORT | STATUS ======================== 9 | UP 10 | DOWN 11 | DOWN 12 | DOWN 13 | UP 15 | DOWN 16 | DOWN VLAN ID : 10 Name : engineering Status : Active ======================== PORT | STATUS ======================== 14 | DOWN VLAN ID : 20 Name : sales

The VLANs added are not yet active. Each individual VLAN can be activated or all VLANs can be activated

The “Pending” VLAN is now “Active”

Start all VLANs

Page 112 of the GarrettCom MNS-6K user manual — Using Tag VLANs
Page 112 · click to enlarge
Page 112

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Status : Active ======================== PORT | STATUS ======================== 14 | DOWN VLAN ID : 30 Name : marketing Status : Active ======================== PORT | STATUS ======================== 14 | DOWN Magnum6K25(port-vlan)## exit Magnum6K25# FIGURE 71 – Example of setting up port based VLANs

Using Tag VLANs

When multiple switches are connected on a network, the VLAN information needs to be propagated on to other switches. In such situations – it is best to use tag based VLANs.

Older versions of MNS-6K the use of tag VLANs needed the set- ingress and set-egress commands to set the flow of incoming and outgoing traffic. These commands are defunct. GarrettCom recommends using the set-port command instead. The commands for setting Tag VLANs are Syntax set-port port=<number|list|range> default id=<number> sets the default VLAN

id (termed PVID in previous versions). Default VLAN id is the VLAN id assigned to the untagged packets received on that port. For Magnum 6K family of switches, the default VLAN id is 1 Syntax set-port port=<number|list|range> filter status=<enable|disable> enables or

disables the VLAN filtering function. When enabled, the switch will drop the packets coming in through a port if the port is not a member of the VLAN. For example, if port 1 is a member of VLANs 10, 20 and 30, if a packet with VLAN id 40 arrives at port 1 it will be dropped Syntax set-port port=<number|list|range> tagging id=<number> status=<tagged|

untagged> defines whether the outgoing packets from a port will be tagged or untagged. This definition is on a per VLAN basis. For example the command set-port port=1 tagging id=10 status=tagged will instruct the switch to tag all packets going out of port 1 to belong to VLAN 10 Syntax set-port port=<number|list|range> join id=<number> adds the specified port(s) to the

specified VLAN id. This command works with active or pending VLANs

Page 113 of the GarrettCom MNS-6K user manual — Why VLANs?
Page 113 · click to enlarge
Page 113

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax set-port port=<number|list|range> leave id=<number> releases a specific port from a

VLAN. For example if port 1 belongs to VLAN 10, 20, 30, 40 the command set-port port=1 leave id=40 makes port 1 belong to VLAN 10, 20, 30, dropping VLAN 40 Syntax show-port [port=<port|list|range>] shows all parameters related to tag vlan for the list of

ports. If the port parameter is omitted, it will display all ports In the example below, we start with Port VLAN and convert to TAG VLAN. We define ports 14 through 16 to belong to VLANs 10, 20 and 30 and the rest of the ports belong to the default VLAN – VLAN 1. Filtering is enabled on ports 14-16. The VLAN setup is done before devices are plugged into ports 14-16 as a result the status of the ports show the port status as DOWN.

1. A word of caution – when TAG VLAN filtering is enabled, there can be serious connectivity repercussions – the only way to recover from that it is to reload the switch without saving the configuration or by modifying the configuration from the console (serial) port 2. There can be either TAG VLAN on MSN-6K or Port VLAN. Both VLANs cannot co-exit at the same time 3. There can only be one default VLAN for the switch. The default is set to VLAN 1 and can be changed to another VLAN. A word of caution on changing the default VLAN as well – there can be repercussions on management as well as multicast and other issues 4. Tag VLAN support VLAN ids from 1 to 4096. VLAN ids more than 2048 are reserved for specific purposes and it is recommended they not be used 5. There are a maximum of 32 VLANs per switch which can be defined and supported

Magnum6K25# vlan type=port Magnum6K25(port-vlan)## show vlan type=port VLAN ID: 1 Name : Default VLAN Status : Active ======================== PORT | STATUS ======================== 9 | UP 10 | DOWN 11 | DOWN 12 | DOWN 13 | UP 15 | DOWN 16 | DOWN

Page 114 of the GarrettCom MNS-6K user manual — Why VLANs?
Page 114 · click to enlarge
Page 114

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

VLAN ID: 10 Name : engineering Status : Active ======================== PORT | STATUS ======================== 14 | DOWN VLAN ID: 20 Name : sales Status : Active ======================== PORT | STATUS ======================== 14 | DOWN VLAN ID: 30 Name : marketing Status : Active ======================== PORT | STATUS ======================== 14 | DOWN Magnum6K25(port-vlan)## stop vlan=all All active VLAN's stopped. Magnum6K25(port-vlan)## exit Magnum6K25# set vlan type=tag VLAN set to Tag-based. Magnum6K25# show active-vlan Tag VLAN is currently active. Magnum6K25# show vlan type=tag VLAN ID: 1 Name : Default VLAN Status : Active PORT | MODE | STATUS 9 | UNTAGGED | UP 10 | UNTAGGED | DOWN

To switch to TAG VLAN, the port VLAN has to be disabled or stopped. Only one type of VLAN can co-exist at the same time. Exit out of Port VLAN configuration mode and set the VLAN type to be Tag VLAN.

Page 115 of the GarrettCom MNS-6K user manual — Why VLANs?
Page 115 · click to enlarge
Page 115

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

11 | UNTAGGED | DOWN 12 | UNTAGGED | DOWN 13 | UNTAGGED | UP 14 | UNTAGGED | DOWN 15 | UNTAGGED | DOWN 16 | UNTAGGED | DOWN Magnum6K25# vlan type=tag Magnum6K25(tag-vlan)## add id=10 name=mkt port=14-16 Tag based vlan Added Successfully. Vlan id :10 Vlan name : mkt Ports :14-16 Magnum6K25(tag-vlan)## edit id=10 name=engineering port=14-16

The edit command can be used to reset the names or other values

Tag based vlan edited Successfully. Vlan id : 10 Vlan name : engineering Ports : 14-16 Magnum6K25(tag-vlan)## add id=20 name=sales port=14-16 Tag based vlan Added Successfully. Vlan id :20 Vlan name : sales Ports :14-16 Magnum6K25(tag-vlan)## add id=20 name=marketing port=14-16 ERROR: Duplicate Vlan Id Magnum6K25(tag-vlan)## add id=30 name=marketing port=14-16 Tag based vlan Added Successfully. Vlan id :30 Vlan name : marketing Ports :14-16 Magnum6K25(tag-vlan)## show vlan type=tag VLAN ID: 1 Name : Default VLAN Status : Active PORT | MODE | STATUS 9 | UNTAGGED | UP 10 | UNTAGGED | DOWN 11 | UNTAGGED | DOWN

Intentionally done to show the effect of adding a duplicate VLAN.

Page 116 of the GarrettCom MNS-6K user manual — Why VLANs?
Page 116 · click to enlarge
Page 116

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

12 | UNTAGGED | DOWN 13 | UNTAGGED | UP 14 | UNTAGGED | DOWN 15 | UNTAGGED | DOWN 16 | UNTAGGED | DOWN VLAN ID: 10 Name : engineering Status : Pending PORT | MODE | STATUS 14 | UNTAGGED | DOWN 15 | UNTAGGED | DOWN 16 | UNTAGGED | DOWN VLAN ID: 20 Name : sales Status : Pending PORT | MODE | STATUS 14 | UNTAGGED | DOWN 15 | UNTAGGED | DOWN 16 | UNTAGGED | DOWN VLAN ID: 30 Name : marketing Status : Pending PORT | MODE | STATUS 14 | UNTAGGED | DOWN 15 | UNTAGGED | DOWN 16 | UNTAGGED | DOWN Magnum6K25(tag-vlan)## start vlan=all All pending VLAN's started. Magnum6K25(tag-vlan)## set-port port=14-16 filter status=enable WARNING: PVID does not match the port(15)'s VLAN ID(s). If you are using telnet session on this port, setting ingress might stop the session.

Enable filtering on the ports required. Note – the MNS-6K software will prompt you to be sure that connectivity is not disrupted.

Page 117 of the GarrettCom MNS-6K user manual — Why VLANs?
Page 117 · click to enlarge
Page 117

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Do you want to continue? [ 'Y' or 'N'] Y WARNING: PVID does not match the port(14)'s VLAN ID(s). If you are using telnet session on this port, setting ingress might stop the session. Do you want to continue? [ 'Y' or 'N'] Y WARNING: PVID does not match the port(16)'s VLAN ID(s). If you are using telnet session on this port, setting ingress might stop the session. Do you want to continue? [ 'Y' or 'N'] Y Ingress Filter Enabled Magnum6K25(tag-vlan)## show vlan type=tag VLAN ID: 1 Name : Default VLAN Status : Active PORT | MODE | STATUS 9 | UNTAGGED | UP 10 | UNTAGGED | DOWN 11 | UNTAGGED | DOWN 12 | UNTAGGED | DOWN 13 | UNTAGGED | UP VLAN ID: 10 Name : engineering Status : Active PORT | MODE | STATUS 14 | UNTAGGED | DOWN 15 | UNTAGGED | DOWN 16 | UNTAGGED | DOWN VLAN ID: 20 Name : sales Status : Active PORT | MODE | STATUS 14 | UNTAGGED | DOWN 15 | UNTAGGED | DOWN 16 | UNTAGGED | DOWN

Page 118 of the GarrettCom MNS-6K user manual — Why VLANs?
Page 118 · click to enlarge
Page 118

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

VLAN ID: 30 Name : marketing Status : Active PORT | MODE | STATUS 14 | UNTAGGED | DOWN 15 | UNTAGGED | DOWN 16 | UNTAGGED | DOWN Magnum6K25(tag-vlan)## set-port port=14-16 tagging id=10 status=tagged Port tagging enabled

VLANs are now active, however, as the packet traverses VLANs the packet should be tagged. This now enabled next.

Magnum6K25(tag-vlan)## set-port port=14-16 tagging id=20 status=tagged Port tagging enabled Magnum6K25(tag-vlan)## set-port port=14-16 tagging id=30 status=tagged Port tagging enabled Magnum6K25(tag-vlan)## show vlan type=tag VLAN ID: 1 Name : Default VLAN Status : Active PORT | MODE | STATUS 9 | UNTAGGED | UP 10 | UNTAGGED | DOWN 11 | UNTAGGED | DOWN 12 | UNTAGGED | DOWN 13 | UNTAGGED | UP VLAN ID: 10 Name : engineering Status : Active PORT | MODE | STATUS 14 | TAGGED | DOWN 15 | TAGGED | DOWN 16 | TAGGED | DOWN VLAN ID: 20 Name : sales Status : Active

Page 119 of the GarrettCom MNS-6K user manual — THE EDIT COMMAND ONLY ASSOCIATES THE PORT WITH
Page 119 · click to enlarge
Page 119

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

PORT | MODE | STATUS 14 | TAGGED | DOWN 15 | TAGGED | DOWN 16 | TAGGED | DOWN VLAN ID: 30 Name : marketing Status : Active PORT | MODE | STATUS 14 | TAGGED | DOWN 15 | TAGGED | DOWN 16 | TAGGED | DOWN FIGURE 72 – Example for Tag VLAN

Before exiting – don’t forget to save the configuration or discard the configuration by doing a reboot.

Tag VLANs and Management

Normally, for security reasons, a user may want to disable management information propagating on a specific VLAN. By default, management information propagates on VLAN 1 (default VLAN). To disable management or to enable management information from propagating on a VLAN, please use the commands listed below: Syntax add id=<vlan Id> [name=<vlan name>] port=<number|list|range>

[forbid=<number|list|range>] [<mgt|nomgt>] – add VLANs GarrettCom recommends to disable management function when the VLANs are added using the add command shown above. By default, management is allowed (enabled) on a VLAN. Syntax edit id=<vlan Id> [name=<vlan name>] port=<number|list|range>

[<mgt|nomgt>] – change VLAN assignment

THE EDIT COMMAND ONLY ASSOCIATES THE PORT WITH

THE VLANS. So for example, if VLAN 5 had port 10-14, an edit command on port 14 only will drop ports 10-13 from VLAN 5. See example below.

Magnum 6K25# vlan type=tag

Page 120 of the GarrettCom MNS-6K user manual — Why VLANs?
Page 120 · click to enlarge
Page 120

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum 6K25(tag-vlan)## add id=5 name=engineering port=10-14 Tag based vlan Added Successfully. Vlan id :5 Vlan name : engineering Ports :10-14 Magnum 6K25(tag-vlan)## add id=10 name=marketing port=15,16 nomgt Tag based vlan Added Successfully. Vlan id :10 Vlan name : marketing Ports :15,16 Magnum 6K25(tag-vlan)## show vlan type=tag VLAN ID: 1 Name : Default VL Status : Active PORT | MODE | STATUS 1 | UNTAGGED | UP 2 | UNTAGGED | DOWN 3 | UNTAGGED | DOWN 4 | UNTAGGED | DOWN 5 | UNTAGGED | DOWN 6 | UNTAGGED | DOWN 7 | UNTAGGED | DOWN 8 | UNTAGGED | DOWN 9 | UNTAGGED | DOWN 10 | UNTAGGED | DOWN 11 | UNTAGGED | DOWN 12 | UNTAGGED | DOWN 13 | UNTAGGED | DOWN 14 | UNTAGGED | DOWN 15 | UNTAGGED | DOWN 16 | UNTAGGED | DOWN VLAN ID: 5 Name : engineering Status : Pending PORT | MODE | STATUS 10 | UNTAGGED | DOWN 11 | UNTAGGED | DOWN 12 | UNTAGGED | DOWN 13 | UNTAGGED | DOWN 14 | UNTAGGED | DOWN VLAN ID: 10

Page 121 of the GarrettCom MNS-6K user manual — Why VLANs?
Page 121 · click to enlarge
Page 121

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Name : marketing Status : Pending Management Port Excluded from this VLAN PORT | MODE | STATUS 15 | UNTAGGED | DOWN 16 | UNTAGGED | DOWN Magnum 6K25(tag-vlan)## edit id=5 port=14 nomgt Tag based vlan edited Successfully. Vlan id : 5 Vlan name : engineering Ports : 14 Magnum 6K25(tag-vlan)## show vlan type=tag id=5 VLAN ID: 5 Name : engineering Status : Pending Management Port Excluded from this VLAN PORT | MODE | STATUS 14 | UNTAGGED | DOWN Magnum 6K25(tag-vlan)## show vlan type=tag id=5 port=10-14 VLAN ID: 5 Name : engineering Status : Pending Management Port Excluded from this VLAN PORT | MODE | STATUS 14 | UNTAGGED | DOWN Magnum 6K25(tag-vlan)## show vlan type=tag VLAN ID: 1 Name : Default VLAN Status : Active PORT | MODE | STATUS

Page 122 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 122 · click to enlarge
Page 122

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

1 | UNTAGGED | UP 2 | UNTAGGED | DOWN 3 | UNTAGGED | DOWN 4 | UNTAGGED | DOWN 5 | UNTAGGED | DOWN 6 | UNTAGGED | DOWN 7 | UNTAGGED | DOWN 8 | UNTAGGED | DOWN 9 | UNTAGGED | DOWN 10 | UNTAGGED | DOWN 11 | UNTAGGED | DOWN 12 | UNTAGGED | DOWN 13 | UNTAGGED | DOWN 14 | UNTAGGED | DOWN 15 | UNTAGGED | DOWN 16 | UNTAGGED | DOWN VLAN ID: 5 Name : engineering Status : Pending Management Port Excluded from this VLAN PORT | MODE | STATUS 14 | UNTAGGED | DOWN VLAN ID: 10 Name : marketing Status : Pending Management Port Excluded from this VLAN PORT | MODE | STATUS 15 | UNTAGGED | DOWN 16 | UNTAGGED | DOWN Magnum 6K25(tag-vlan)## FIGURE 73 – Editing the VLAN information for enabling or disabling management

List of commands in this chapter

Syntax set vlan type=<port|tag|none> defines the VLAN type

Page 123 of the GarrettCom MNS-6K user manual — Why VLANs?
Page 123 · click to enlarge
Page 123

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax configure vlan type=port enter the VLAN configuration commands Syntax vlan type=port enter the VLAN configuration commands Syntax add id=<vlan Id> [name=<vlan name>] port=<number|list|range>

[forbid=<number|list|range>] [<mgt|nomgt>] - adding VLAN Syntax edit id=<vlan id> [name=<vlan name>] port=<number|list|range>

[<mgt|nomgt>] - edit existing VLAN name Syntax start vlan=<name|number|list|range> activate the VLAN configuration Syntax save save the configuration (including the VLAN configuration) Syntax show vlan type=<port|tag> [<id=vlanid>] display specific VLAN information Syntax set-port port=<number|list|range> default id=<number> sets the default VLAN id.

For Magnum 6K family of switches, the default VLAN id is 1, unless changed using this command Syntax set-port port=<number|list|range> filter status=<enable|disable> enables or disables

the VLAN filtering function. Syntax set-port port=<number|list|range> tagging id=<number> status=<tagged|

untagged> defines whether the outgoing packets from a port will be tagged or untagged. Syntax set-port port=<number|list|range> join id=<number> adds the specified port(s) to the

specified VLAN id Syntax set-port port=<number|list|range> leave id=<number> releases a specific port from a

VLAN Syntax show-port [port=<port|list|range>] shows all parameters related to tag vlan for the list of ports.

If the port parameter is omitted, it will display all ports

Page 124 of the GarrettCom MNS-6K user manual — j
Page 124 · click to enlarge
Page 124

Chapter 10

10 – Spanning Tree Protocol (STP)

Create and manage alternate paths to the network

panning Tree Protocol was designed to avoid loops in an Ethernet network. An Ethernet network using switches can have redundant paths – this may however cause loops and to prevent the loops MNS-6K software uses spanning tree protocol. As a manager of the MNS-6K software, controlling n which span the traffic traverses is necessary. It is also necessary to specify the parameters of STP. STP is available as the IEEE 802.1d protocol and is a standard of the IEEE. S

STP features and operation

j

The switch uses the IEEE 802.1d Spanning Tree Protocol (STP). When STP is enabled, it ensures that only one path at a time is active between any two nodes on the network. In networks where more than one physical path exists between two nodes, STP ensures only a single path is active by blocking all redundant paths. Enabling STP is necessary to avoid loops and duplicate messages. This duplication leads to a “broadcast storm” or other erratic behavior that can bring down the network.

As recommended in the IEEE 802.1Q VLAN standard, the Magnum 6K family of switches uses single-instance STP. This means a single spanning tree is created to make sure there are no network loops associated with any of the connections to the switch. This works regardless of whether VLANs are configured on the switch. Thus, these switches do not distinguish between VLANs when identifying redundant physical links. The switch automatically senses port identity and type, and automatically defines port cost and priority for each type. The MNS-6K software allows a manager to adjust the cost, priority, the mode for each port as well as the global STP parameter values for the switch. While allowing only one active path through a network at any time, STP retains any redundant physical path to serve as a backup (blocked) path in case the existing active path fails. Thus, if an active path fails, STP automatically activates (unblocks) an available backup to serve as the new active path for as long as the original active path is down. The table below lists the default values of the STP variables.

Page 125 of the GarrettCom MNS-6K user manual — Using STP
Page 125 · click to enlarge
Page 125

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Variable or Attribute Default Value

reconfiguring general operation priority 32768

Bridge maximum age 20 seconds

Hello time 2 seconds

Forward delay 15 seconds

Reconfiguring per-port STP path cost 0

Monitoring of STP Not Available

Root Port Not set

Figure 74 – STP default values – refer to next section “Using STP” for more detailed explanation on the variables

1. By default, STP is disabled. To use STP, it has to be manually enabled.
2. If you are using tagged VLANs, at least one untagged VLAN must be available for the BPDU’s to propagate through the network to update STP status.

Using STP

The commands used for configuring STP are listed below.

Syntax show stp <config|ports > - regardless of whether STP is enabled or disabled (default) this

command lists the switch’s full STP configuration, including general settings and port settings

Magnum6K25# show stp config STP CONFIGURATION Spanning Tree Enabled(Global) : NO Spanning Tree Enabled(Ports) : YES, 9,10,11,12,13,14,15,16 Protocol : Normal STP Bridge ID : 80:00:00:20:06:25:ed:80 Bridge Priority : 32768 Bridge Forward Delay : 15

STP capabilities Disabled · Priority 32768 · Mode Normal

Page 126 of the GarrettCom MNS-6K user manual — STP features and operation
Page 126 · click to enlarge
Page 126

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Bridge Hello Time : 2 Bridge Max Age : 20 Root Port : 0 Root Path Cost : 0 Designated Root : 80:00:00:20:06:25:ed:80 Designated Root Priority : 32768 Root Bridge Forward Delay : 15 Root Bridge Hello Time : 2 Root Bridge Max Age : 20 RSTP CONFIGURATION

Rapid STP/STP Enabled(Global)NO Magnum6K25# F IGURE 75 – Viewing STP configuration

The variables listed above are: Spanning Tree Enabled (Global): indicates whether STP is enabled or disabled globally i.e. if the values is YES, all ports have STP enabled, otherwise, all ports have STP disabled Spanning Tree Enabled (Ports): indicates which ports have STP enabled – note in the figure the ports 9 through 16 are STP enabled, but STP functionality is not enabled – so STP will not perform on these ports Bridge Priority: specifies the switch (bridge) priority value. This value is used along with the switch MAC address to determine which switch in the network is the root device. Lower values mean higher priority. Value ranges from 0 to 65535. Default value is 32768 Bridge Forward Delay: indicates the time duration the switch will wait from listening to learning states and from learning to forwarding states. The value ranges from 4 to 30 seconds. Default value is 15 Bridge Hello Time: When the switch is the root device, this is the time between messages being transmitted. The value is from 1 to 10 seconds. Default value is 2 seconds Bridge Max Age: This is the maximum time a message with STP information is allowed by the switch before the switch discards the information and updates the address table again. Value ranges from 6 to 40 seconds with default value of 20 seconds Root Port: indicates the port number, which is elected as the root port of the switch. A root port of “0” indicates STP is disabled Root Path Cost: A path cost is assigned to individual ports for the switch to determine which ports are the forwarding points. A higher cost means more loops, a lower cost means fewer loops. More loops equal more traffic and a tree which takes a long time to converge – resulting in a slower system

Page 127 of the GarrettCom MNS-6K user manual — STP features and operation
Page 127 · click to enlarge
Page 127

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Designated Root: shows the MAC address of the bridge in the network elected or designated as the root bridge. Normally when STP is not enabled the switch designates itself as the root switch Designated Root Priority: shows the designated root bridge’s priority. Default value is 32768 Root Bridge Forward Delay: indicates the designated root bridge’s forward delay. This is the time the switch waits before it switches from the listening to the forwarding state. The default is 15 seconds. This value can be set between 4-30 seconds Root Bridge Hello Time: indicates the designated root bridge’s hello time. Hello information is sent out every 2 seconds Root Bridge Max Age: indicates the designated root bridge’s maximum age – after which it discards the information as being old and receives new updates

These variables can be changed using the “priority”, “cost”, “port” and “timers” commands described later in this chapter.

Magnum6K25# show stp ports STP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:09 10 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0a 11 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0b 12 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0c 13 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0d 14 TP(10/100 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0e 15 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0f 16 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:10 Magnum6K25# FIGURE 76 – STP Port status information

The variables shown above are

Port#: indicates the port number. Value ranges from 01 to max number of ports in the switch Type: indicates the type of port – TP indicates Twisted Pair

Page 128 of the GarrettCom MNS-6K user manual — STP features and operation
Page 128 · click to enlarge
Page 128

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Priority: STP uses this to determine which ports are used for forwarding. Lower the number means higher priority. Value ranges from 0 to 255. Default is 128 Path Cost: This is the assigned port cost value used for the switch to determine the forwarding points. Values range from 1 to 65535 State: indicates the STP state of individual ports. Values can be Listening, Learning, Forwarding, Blocking and Disabled. Des. Bridge: This is the port’s designated root bridge Des. Port: This is the port’s designated root port To enable or disable STP, enter the STP configuration mode and use the “stp <enable|disable>” command. Syntax stp – STP Configuration mode Syntax stp <enable|disable> - Start (Enable) or stop (Disable) STP Syntax set stp type=<stp|rstp> - set the spanning tree protocol to be IEEE 802.1d or 802.1w

(Rapid Spanning Tree Protocol) Syntax show active-stp – Display which version of STP is currently active

Incorrect STP settings can adversely affect network performance. GarrettCom Inc. recommends starting with the default STP settings. Changing the settings requires a detailed understanding of STP. For more information on STP, please refer to the IEEE 802.1d standard.

Magnum6K25# show active-stp Current Active Mode: RSTP. RSTP is Disabled. Magnum6K25# stp ERROR: Invalid Command Magnum6K25#set stp type=stp STP Mode set to STP. Magnum6K25# stp Magnum6K25(stp)## stp enable Successfully set the STP status Magnum6K25(stp)## show stp config

Page 129 of the GarrettCom MNS-6K user manual — STP features and operation
Page 129 · click to enlarge
Page 129

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

STP CONFIGURATION Spanning Tree Enabled(Global) : YES Spanning Tree Enabled(Ports) : YES, 9,10,11,12,13,14,15,16 Protocol : Normal STP Bridge ID : 80:00:00:20:06:25:ed:80 Bridge Priority : 32768 Bridge Forward Delay : 15 Bridge Hello Time : 2 Bridge Max Age : 20 Root Port : 0 Root Path Cost : 0 Designated Root : 80:00:00:20:06:25:ed:80 Designated Root Priority : 32768 Root Bridge Forward Delay : 15 Root Bridge Hello Time : 2 Root Bridge Max Age : 20 RSTP CONFIGURATION Rapid STP/STP Enabled(Global) : NO Magnum6K25(stp)## show stp ports STP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 100 Forwarding 80:00:00:20:06:25:ed:80 80:09 10 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0a 11 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0b 12 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0c 13 TP(10/100) 128 19 Forwarding 80:00:00:20:06:25:ed:80 80:0d 14 TP(10/100 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0e 15 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0f 16 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:10 Magnum6K25(stp)## FIGURE 77 – Enabling STP

Syntax priority [port=<number|list|range>] value=<0-255 | 0-65535> - specifies the

port or switch level priority. When a port(s) are specified the priority is associated with ports and their value is 0-255. If no ports are specified, then the switch (bridge) priority is specified and its value is 0-65535 Syntax cost port=<number|list|range> value=<0-65535> - cost is specific to a port and the

port(s) have to be specified Syntax port port=<number|list|range> status=<enable|disable> - specific ports may

not need to participate in STP process. These ports typically would be end-stations. If you are not sure – let MNS-6K software make the decisions Syntax timers forward-delay=<4-30> hello=<1-10> age=<6-40> - change the STP

Forward Delay, Hello timer and Aging timer values

Page 130 of the GarrettCom MNS-6K user manual — STP features and operation
Page 130 · click to enlarge
Page 130

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Priority: specifies the switch (bridge) priority value. This value is used along with the switch MAC address to determine which switch in the network is the root device. Lower values mean higher priority. Value ranges from 0 to 65535. Default value is 32768

Cost: A path cost is assigned to individual ports for the switch to determine which ports are the forwarding points. A higher cost means the link is “more expensive” to use and falls in the passive mode compared to the link with a lower cost. Value ranges from 0 to 65535. Default value is 32768 Status: Enables or disables a port from participating in STP discovery. Its best to only allow trunk ports to participate in STP. End stations need not participate in STP process. Forward-Delay: indicates the time duration the switch will wait from listening to learning states and from learning to forwarding states. The value ranges from 4 to 30 seconds. Default value is 15 Hello: When the switch is the root device, this is the time between messages being transmitted. The value is from 1 to 10 seconds. Default value is 2 seconds Age: This is the maximum time a message with STP information is allowed by the switch before the switch discards the information and updates the address table again. Value ranges from 6 to 40 seconds with default value of 20 seconds

Magnum6K25(stp)## show stp config STP CONFIGURATION Spanning Tree Enabled(Global) : NO Spanning Tree Enabled(Ports) : YES, 9,10,11,12,13,14,15,16 Protocol : Normal STP Bridge ID : 80:00:00:20:06:25:ed:80 Bridge Priority : 32768 Bridge Forward Delay : 15 Bridge Hello Time : 2 Bridge Max Age : 20 Root Port : 0 Root Path Cost : 0 Designated Root : 80:00:00:20:06:25:ed:80 Designated Root Priority : 32768 Root Bridge Forward Delay : 15 Root Bridge Hello Time : 2 Root Bridge Max Age : 20 RSTP CONFIGURATION Rapid STP/STP Enabled(Global) : NO Magnum6K25(stp)## show stp ports

Page 131 of the GarrettCom MNS-6K user manual — STP features and operation
Page 131 · click to enlarge
Page 131

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

STP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:09 10 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0a 11 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0b 12 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0c 13 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0d 14 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0e 15 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0f 16 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:10 Magnum6K25(stp)## stp enable Successfully set the STP status Magnum6K25(stp)## show stp config STP CONFIGURATION Spanning Tree Enabled(Global) : YES Spanning Tree Enabled(Ports) : YES, 9,10,11,12,13,14,15,16 Protocol : Normal STP Bridge ID : 80:00:00:20:06:25:ed:80 Bridge Priority : 32768 Bridge Forward Delay : 15 Bridge Hello Time : 2 Bridge Max Age : 20 Root Port : 0 Root Path Cost : 0 Designated Root : 80:00:00:20:06:25:ed:80 Designated Root Priority : 32768 Root Bridge Forward Delay : 15 Root Bridge Hello Time : 2 Root Bridge Max Age : 20 RSTP CONFIGURATION Rapid STP/STP Enabled(Global) : NO Magnum6K25(stp)## show stp ports STP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 100 Forwarding 80:00:00:20:06:25:ed:80 80:09 10 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0a 11 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0b 12 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0c 13 TP(10/100) 128 19 Forwarding 80:00:00:20:06:25:ed:80 80:0d

Ports which have devices connected to it now participate in STP.

Page 132 of the GarrettCom MNS-6K user manual — STP features and operation
Page 132 · click to enlarge
Page 132

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

14 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0e 15 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0f 16 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:10 Magnum6K25(stp)## priority value=15535 Successfully set the bridge priority Magnum6K25(stp)## show stp config STP CONFIGURATION Spanning Tree Enabled(Global) : YES

STP is now enabled. Note the default values for the different variables discussed.

Spanning Tree Enabled(Ports) : YES, 9,10,11,12,13,14,15,16 Protocol : Normal STP Bridge ID : 80:00:00:20:06:25:ed:80 Bridge Priority : 15535 Bridge Forward Delay : 15 Bridge Hello Time : 2 Bridge Max Age : 20 Root Port : 0 Root Path Cost : 0 Designated Root : 80:00:00:20:06:25:ed:80 Designated Root Priority : 15535 Root Bridge Forward Delay : 15 Root Bridge Hello Time : 2 Root Bridge Max Age : 20 RSTP CONFIGURATION Rapid STP/STP Enabled(Global) : NO Magnum6K25(stp)## priority port=13 value=20 Successfully set the priority for port 13 Magnum6K25(stp)## show stp ports STP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 100 Forwarding 80:00:00:20:06:25:ed:80 80:09 10 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0a 11 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0b 12 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0c 13 TP(10/100) 20 19 Forwarding 80:00:00:20:06:25:ed:80 80:0d 14 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0e 15 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0f 16 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:10 Magnum6K25(stp)## cost port=13 value=20

Page 133 of the GarrettCom MNS-6K user manual — STP features and operation
Page 133 · click to enlarge
Page 133

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Setting cost for STP...Successfully set the path cost for port 13 Magnum6K25(stp)## show stp ports STP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 100 Forwarding 80:00:00:20:06:25:ed:80 80:09 10 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0a 11 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0b 12 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0c 13 TP(10/100) 20 20 Forwarding 80:00:00:20:06:25:ed:80 80:0d 14 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0e 15 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0f 16 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:10 Magnum6K25(stp)## port port=9 status=disable Successfully set the STP status for port 9 Magnum6K25(stp)## show stp ports STP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 10 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0a 11 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0b 12 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0c 13 TP(10/100) 20 19 Forwarding 80:00:00:20:06:25:ed:80 80:0d 14 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0e 15 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0f 16 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:10 Magnum6K25(stp)## port port=9 status=enable Successfully set the STP status for port 9 Magnum6K25(stp)## show stp ports STP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 100 Forwarding 80:00:00:20:06:25:ed:80 80:09 10 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0a 11 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0b 12 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0c 13 TP(10/100) 20 20 Forwarding 80:00:00:20:06:25:ed:80 80:0d 14 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0e 15 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:0f 16 TP(10/100) 128 100 Disabled 80:00:00:20:06:25:ed:80 80:10

Since Port #9 does not participate in STP – it is not listed here. Any changes made to STP parameters on Port #9 will be ignored.

Page 134 of the GarrettCom MNS-6K user manual — STP features and operation
Page 134 · click to enlarge
Page 134

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25(stp)## show stp config STP CONFIGURATION Spanning Tree Enabled(Global) : YES Spanning Tree Enabled(Ports) : YES, 9,10,11,12,13,14,15,16 Protocol : Normal STP Bridge ID : 80:00:00:20:06:25:ed:80 Bridge Priority : 15535 Bridge Forward Delay : 15 Bridge Hello Time : 2 Bridge Max Age : 20 Root Port : 0 Root Path Cost : 0 Designated Root : 80:00:00:20:06:25:ed:80 Designated Root Priority : 15535 Root Bridge Forward Delay : 15 Root Bridge Hello Time : 2 Root Bridge Max Age : 20 RSTP CONFIGURATION Rapid STP/STP Enabled(Global) : NO Magnum6K25(stp)## timers forward-delay=20 hello=5 age=40 ERROR: Invalid Values Max Age = (2*(Hello-Time+1)) Magnum6K25(stp)## timers forward-delay=20 hello=5 age=30 Successfully set the bridge time parameters Magnum6K25(stp)## show stp config

The age parameter is out of range as per IEEE 802.1d specifications.

STP CONFIGURATION Spanning Tree Enabled(Global) : YES Spanning Tree Enabled(Ports) : YES, 9,10,11,12,13,14,15,16 Protocol : Normal STP Bridge ID : 80:00:00:20:06:25:ed:80 Bridge Priority : 15535 Bridge Forward Delay : 20 Bridge Hello Time : 5 Bridge Max Age : 30 Root Port : 0 Root Path Cost : 0 Designated Root : 80:00:00:20:06:25:ed:80 Designated Root Priority : 15535 Root Bridge Forward Delay : 20 Root Bridge Hello Time : 5 Root Bridge Max Age : 30

Page 135 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 135 · click to enlarge
Page 135

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

RSTP CONFIGURATION Rapid STP/STP Enabled(Global) : NO Magnum6K25(stp)##

FIGURE 78 – Configuring STP parameters

List of commands in this chapter

Syntax show stp <config|ports > - regardless of whether STP is enabled or disabled (default) this

command lists the switch’s full STP configuration, including general settings and port settings Syntax stp – STP Configuration mode Syntax stp <enable|disable> - Start (Enable) or stop (Disable) STP Syntax priority [port=<number|list|range>] value=<0-255 | 0-65535> - specifies the port or

switch level priority. When a port(s) are specified the priority is associated with ports and their value is 0- 255. If no ports are specified, then the switch (bridge) priority is specified and its value is 0-65535 Syntax cost port=<number|list|range> value=<0-65535> - cost is specific to a port and the port(s)

have to be specified Syntax port port=<number|list|range> status=<enable|disable> - specific ports may not need to

participate in STP process. These ports typically would be end-stations. If you are not sure – let MNS-6K software make the decisions

Syntax timers forward-delay=<4-30> hello=<1-10> age=<6-40> - change the STP Forward

Delay, Hello timer and Aging timer values

Page 136 of the GarrettCom MNS-6K user manual — j
Page 136 · click to enlarge
Page 136

Chapter 11

11 – Rapid Spanning Tree Protocol (RSTP)

Create and manage alternate paths to the network

apid Spanning Tree Protocol (RTSP), like STP, was designed to avoid loops in an Ethernet network. Rapid Spanning Tree Protocol (RSTP) (IEEE 802.1w) is an evolution of the Spanning Tree Protocol (STP) (802.1d standard) and provides for faster spanning tree convergence after a topology change. R

j

The IEEE 802.1d Spanning Tree Protocol (STP) was developed to allow the construction of robust networks that incorporate redundancy while pruning the active topology of the network to prevent loops. While STP is effective, it requires that frame transfer must halt after a link outage. This halt is until all bridges in the network are sure to be aware of the new topology. Using STP (IEEE 802.1d) recommended values, this period lasts 30 seconds.

Rapid Spanning Tree Protocol (IEEE 802.1w) is a further evolution of the 802.1d Spanning Tree Protocol. It replaces the settling period with an active handshake between switches (bridges) that guarantees topology information to be rapidly propagated through the network. RSTP converges in less than one second to six seconds. RSTP also offers a number of other significant innovations. These include

  • Topology changes in STP must be passed to the root bridge before they can be propagated to the network. Topology changes in RSTP can be originated from and acted upon by any designated switch (bridge), leading to more rapid propagation of address information
  • STP recognizes one state - blocking for ports that should not forward any data or information. RSTP explicitly recognizes two states or blocking roles - alternate and backup port including them in computations of when to learn and forward and when to block
  • STP relays configuration messages received on the root port going out of its designated ports. If an STP switch (bridge) fails to receive a message from its neighbor it cannot be sure where along the path to the root a failure occurred.

RSTP concepts

Page 137 of the GarrettCom MNS-6K user manual — Transition from STP to RSTP
Page 137 · click to enlarge
Page 137

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

  • RSTP switches (bridges) generate their own configuration messages, even if they fail to receive one from the root bridge. This leads to quicker failure detection
  • RSTP offers edge port recognition, allowing ports at the edge of the network to forward frames immediately after activation while at the same time protecting them against loops
  • An improvement in RSTP allows configuration messages to age more quickly preventing them from “going around in circles” in the event of a loop

RSTP has three states. They are discarding, learning and forwarding. The discarding state is entered when the port is first taken into service. The port does not learn addresses in this state and does not participate in frame transfer. The port looks for STP traffic in order to determine its role in the network. When it is determined that the port will play an active part in the network, the state will change to learning. The learning state is entered when the port is preparing to play an active member of the network. The port learns addresses in this state but does not participate in frame transfer. In a network of RSTP switches (bridges) the time spent in this state is usually quite short. RSTP switches (bridges) operating in STP compatibility mode will spend between 6 to 40 seconds in this state. After ‘learning’ the bridge will place the port in the forwarding state. While in this state the port both learns addresses and participates in frame transfer while in this state.

The result of these enhanced states is that the IEEE 802.1d version of spanning tree (STP) can take a fairly long time to resolve all the possible paths and to select the most efficient path through the network. The IEEE 802.1w Rapid reconfiguration of Spanning Tree significantly reduces the amount of time it takes to establish the network path. The result is reduced network downtime and improved network robustness. In addition to faster network reconfiguration, RSTP also implements greater ranges for port path costs to accommodate the higher connection speeds that are being implemented. Proper implementations of RSTP (by switch vendors) is designed to be compatible with IEEE 802.1d STP. GarrettCom recommends that you employ RSTP or STP in your network.

Transition from STP to RSTP

IEEE 802.1w RSTP is designed to be compatible with IEEE 802.1D STP. Even if all the other devices in your network are using STP, you can enable RSTP on your Magnum 6K family of switches. The default configuration values of the RSTP available in MNS-6K software will ensure that your switch will interoperate effectively with the existing STP devices. RSTP automatically detects when the switch ports are connected to non-RSTP devices using spanning tree and communicates with those devices using 802.1d STP BPDU packets. Even though RSTP interoperates with STP, RSTP is so much more efficient at establishing the network path and the network convergence in case of a failure is very fast. For this reason,

Page 138 of the GarrettCom MNS-6K user manual — Configuring RSTP
Page 138 · click to enlarge
Page 138

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

GarrettCom recommends that all your network devices be updated to support RSTP. RSTP offers convergence times typically of less than one second. However, to make best use of RSTP and achieve the fastest possible convergence times there are some changes that you should make to the RSTP default configuration.

1. GarrettCom Inc. provides downloadable software Fault Timing Analyzer (FTA) for testing how quickly a network recovers from a fault, once the redundancy feature such as STP or RSTP is configured on the switches (bridges). This software can be downloaded from the GarrettCom site. This software is available at http://www.garrettcom.com/ftaform.htm 2. Under some circumstances it is possible for the rapid state transitions employed by RSTP to result in an increase in the rates of frame duplication and the order in which the frames are sent and received. In order to allow RSTP switches to support applications and protocols that may be sensitive to frame duplication and out of sequence frames, RSTP may have to be explicitly set to be compatible with STP. This explicit setting is called setting the “Force Protocol Version” parameter to be STP compatible. This parameter should be set to all ports on a given switch 3. As indicated above, one of the benefits of RSTP is the implementation of a larger range of port path costs which accommodates higher network speeds. New default values have also been implemented for the path costs associated with the different network speeds. This could create incompatibility between devices running the older implementations of STP a switch running RSTP 4. If you are using tagged VLANs, at least one untagged VLAN must be available for the BPDU’s to propagate through the network to update STP status. 5. RSTP is needed for RS-Ring on the GarrettCom Magnum 6K family of switches.

Configuring RSTP

The commands to setup and configure RSTP on MNS-6K are Syntax set stp type=<stp|rstp> - Set the switch to support RSTP or change it back to STP. Need to save

and reboot the switch after this command Syntax rstp – enter the RSTP configuration mode Syntax rstp <enable|disable> - enable RSTP – by default, this is disabled and has to be manually

activated

Page 139 of the GarrettCom MNS-6K user manual — [migration=<enable>] [edge=<enable|disable>] [p2p=<on|off|auto>]
Page 139 · click to enlarge
Page 139

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax port port=<number|list|range> [status=<enable|disable>]

[migration=<enable>] [edge=<enable|disable>] [p2p=<on|off|auto>]

Example port port=<number|list|range> p2p= off - Set the “point-to-point” value to off on

all ports that are connected to shared LAN segments (i.e. connections to hubs). The default value is auto. P2P ports would typically be end stations or computers on the network Example port port=<number|list|range> edge=enable – enable all ports connected to

other hubs, bridges and switches as edge ports Example port port=<number|list|range> migration=enable – set this for all ports

connected to other devices such as hubs, bridges and switches known to support IEEE 802.1d STP services, but cannot support RSTP services Syntax show active-stp – status whether STP or RSTP is running Syntax show stp <config|ports> – display the RSTP or STP parameters

Magnum6K25# rstp Magnum6K25(rstp)## show rstp config RSTP CONFIGURATION Rapid STP/STP Enabled(Global) : NO Magnum6K25(rstp)## rstp enable Successfully set the RSTP status Magnum6K25(rstp)## show active-stp Current Active Mode: RSTP. RSTP is Enabled. Magnum6K25(rstp)## show stp config RSTP CONFIGURATION Rapid STP/STP Enabled(Global) : YES RSTP/STP Enabled Ports : 9,10,11,12,13,14,15,16 Protocol : Normal RSTP Bridge ID : 00:00:00:20:06:25:ed:89 Bridge Priority : 0 Bridge Forward Delay : 15 Bridge Hello Time : 02 Bridge Max Age : 20 Root Port : 0 Root Path Cost : 0 Designated Root : 00:00:00:20:06:25:ed:89

Page 140 of the GarrettCom MNS-6K user manual — RSTP concepts
Page 140 · click to enlarge
Page 140

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Designated Root Priority : 0 Root Bridge Forward Delay : 15 Root Bridge Hello Time : 02 Root Bridge Max Age : 20 Topology Change count : 0 Time Since topology Chg : 12 FIGURE 79 – Enabling RSTP and reviewing the RSTP variables

The variables listed by the “show stp config” command are: Rapid Spanning Tree Enabled (Global): indicates whether STP is enabled or disabled globally i.e. if the values is YES, all ports have STP enabled, otherwise, all ports have STP disabled Rapid Spanning Tree Enabled Ports: indicates which ports have RSTP enabled Protocol: indicates type of RSTP protocol active Bridge Priority: specifies the switch (bridge) priority value. This value is used along with the switch MAC address to determine which switch in the network is the root device. Lower values mean higher priority. Value ranges from 0 to 65535. Default value is 0 Bridge Forward Delay: indicates the time duration the switch will wait from listening to learning states and from learning to forwarding states. The value ranges from 4 to 30 seconds. Default value is 15 Bridge Hello Time: when the switch is the root device, this is the time between messages being transmitted. The value is from 1 to 10 seconds. Default value is 2 seconds Bridge Max Age: this is the maximum time a message with STP information is allowed by the switch before the switch discards the information and updates the address table again. Value ranges from 6 to 40 seconds with default value of 20 seconds Root Port: indicates the port number, which is elected as the root port of the switch. A root port of “0” indicates STP is disabled Root Path Cost: a path cost is assigned to individual ports for the switch to determine which ports are the forwarding points. A higher cost means more loops; a lower cost means fewer loops. More loops equal more traffic and a tree which takes a long time to converge – resulting in a slower system Designated Root: shows the MAC address of the bridge in the network elected or designated as the root bridge. Designated Root Priority: shows the designated root bridge’s priority. Default value is 0

Page 141 of the GarrettCom MNS-6K user manual — RSTP concepts
Page 141 · click to enlarge
Page 141

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Root Bridge Forward Delay: indicates the designated root bridge’s forward delay. This is the time the switch waits before it switches from the listening to the forwarding state. The default is 15 seconds. This value can be set between 4-30 seconds Root Bridge Hello Time: indicates the designated root bridge’s hello time. Hello information is sent out every 2 seconds Root Bridge Max Age: indicates the designated root bridge’s maximum age – after which it discards the information as being old and receives new updates Topology Change count: since the last reboot, the number of times the topology has changed. Use this in conjunction with “show uptime” to find the frequency of the topology changes Time Since topology Change: number of seconds since the last topology change

Magnum6K25(rstp)## show stp ports RSTP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 2000000 Forwarding 00:00:00:20:06:25:ed:89 00:09 10 TP(10/100) 128 2000000 Disabled 00:0a 11 TP(10/100) 128 2000000 Disabled 00:0b 12 TP(10/100) 128 2000000 Disabled 00:0c 13 TP(10/100) 128 200000 Forwarding 00:00:00:20:06:25:ed:89 00:0d 14 TP(10/100) 128 2000000 Disabled 00:0e 15 TP(10/100) 128 2000000 Disabled 00:0f 16 TP(10/100) 128 2000000 Disabled 00:10 Magnum6K25(rstp)## FIGURE 80 – Reviewing the RSTP port parameters

The variables listed by the “show stp config” command are: Port#: indicates the port number. Value ranges from 01 to max number of ports in the switch Type: indicates the type of port – TP indicates Twisted Pair Priority: STP uses this to determine which ports are used for forwarding. Lower the number means higher priority. Value ranges from 0 to 255. Default is 128 Path Cost: This is the assigned port cost value used for the switch to determine the forwarding points. Values range from 1 to 2000000. Lower the value, lower the cost and hence the preferred route. The costs for different Ethernet speeds are shown below. The Path cost in STP is compared to the path cost in RSTP.

Page 142 of the GarrettCom MNS-6K user manual — Port Type STP Path cost RSTP Path cost
Page 142 · click to enlarge
Page 142

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Port Type STP Path cost RSTP Path cost

10 Mbps 100 2,000,000

100 Mbps 19 200,000

1 Gbps 4 20,000

10 Gbps 2 2,000

Figure 81 – Path cost as defined in IEEE 802.1d (STP) and 802.1w (RSTP)

State: indicates the STP state of individual ports. Values can be Listening, Learning, Forwarding, Blocking and Disabled. Des. Bridge: this is the port’s designated root bridge Des. Port: this is the port’s designated root port Another screen capture of the same command, from a larger network with several switches is shown below.

Magnum6K25# show stp ports RSTP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 01 TP(10/100) 128 2000000 Disabled 00:01 02 TP(10/100) 128 2000000 Disabled 00:02 03 TP(10/100) 128 2000000 Disabled 00:03 04 TP(10/100) 128 2000000 Disabled 00:04 05 TP(10/100) 128 2000000 Disabled 00:05 06 TP(10/100) 128 200000 Forwarding 80:00:00:20:06:30:00:01 00:06 07 TP(10/100) 128 200000 Discarding 80:00:00:20:06:2b:0f:e1 00:07 08 TP(10/100) 128 2000000 Disabled 00:08 09 Gigabit 128 20000 Forwarding 80:00:00:20:06:2b:0f:e1 00:09 10 Gigabit 128 20000 Forwarding 80:00:00:20:06:30:00:01 00:0a Magnum6K25# FIGURE 82 – RSTP information from a network with multiple switches. Note the “show stp ports” command can be executed from the manager level prompt or from rstp configuration state as shown in the screen captures earlier.

In this example, ports 9,10 have a path cost of 20,000 and are the least cost paths. These ports are connected to other switches and the ports are enabled as forwarding ports. Ports 6, 7 are also

Page 143 of the GarrettCom MNS-6K user manual — RSTP concepts
Page 143 · click to enlarge
Page 143

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

connected to other switches. From the state column, it indicates that port 7 is in a standby state as that port is discarding all traffic. More CLI commands associated with RSTP in the RSTP configuration mode are: Syntax forceversion <stp|rstp> - set the STP or RSTP compatibility mode Syntax show-forceversion - the current force version Syntax show-timers – show the values of the timers set for RSTP Syntax priority [port=<number|list|range>] value=<0-255 | 0-65535> - specifies the port or

switch level priority. When a port(s) are specified the priority is associated with ports and their value is 0- 255. If no ports are specified, then the switch (bridge) priority is specified and its value is 0-65535 Syntax cost port=<number|list|range> value=<0-65535> - cost is specific to a port and the port(s)

have to be specified Syntax port port=<number|list|range> status=<enable|disable> - specific ports may not need to

participate in STP process. These ports typically would be end-stations. If you are not sure – let MNS-6K software make the decisions

Syntax timers forward-delay=<4-30> hello=<1-10> age=<6-40> - change the STP Forward delay,

Hello timer and Aging timer values Priority: specifies the switch (bridge) priority value. This value is used along with the switch MAC address to determine which switch in the network is the root device. Lower values mean higher priority. Value ranges from 0 to 65535. Default value is 32768 Cost: A path cost is assigned to individual ports for the switch to determine which ports are the forwarding points. A higher cost means the link is “more expensive” to use and falls in the passive mode compared to the link with a lower cost. Value ranges from 0 to 65535. Default value is 32768 Status: Enables or disables a port from participating in STP discovery. It’s best to only allow trunk ports to participate in STP. End stations need not participate in STP process. Forward-Delay: indicates the time duration the switch will wait from listening to learning states and from learning to forwarding states. The value ranges from 4 to 30 seconds. Default value is 15 Hello: When the switch is the root device, this is the time between messages being transmitted. The value is from 1 to 10 seconds. Default value is 2 seconds

Page 144 of the GarrettCom MNS-6K user manual — RSTP concepts
Page 144 · click to enlarge
Page 144

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Age: This is the maximum time a message with STP information is allowed by the switch before the switch discards the information and updates the address table again. Value ranges from 6 to 40 seconds with default value of 20 seconds

Magnum6K25# rstp Magnum6K25(rstp)## show stp config RSTP CONFIGURATION Rapid STP/STP Enabled(Global) : NO Magnum6K25(rstp)## show active-stp Current Active Mode: RSTP. RSTP is Disabled. Magnum6K25(rstp)## rstp enable Successfully set the RSTP status Magnum6K25(rstp)## show active-stp Current Active Mode: RSTP. RSTP is Enabled. Magnum6K25(rstp)## show stp config RSTP CONFIGURATION Rapid STP/STP Enabled(Global) : YES RSTP/STP Enabled Ports : 9,10,11,12,13,14,15,16 Protocol : Normal RSTP Bridge ID : 00:00:00:20:06:25:ed:89 Bridge Priority : 0 Bridge Forward Delay : 15 Bridge Hello Time : 02 Bridge Max Age : 20 Root Port : 0 Root Path Cost : 0 Designated Root : 00:00:00:20:06:25:ed:89 Designated Root Priority : 0 Root Bridge Forward Delay : 15 Root Bridge Hello Time : 02 Root Bridge Max Age : 20 Topology Change count : 0 Time Since topology Chg : 33 Magnum6K25(rstp)## show stp ports RSTP Port Configuration

Check status of STP or RSTP. This command shows STP or RSTP is disabled.

Page 145 of the GarrettCom MNS-6K user manual — RSTP concepts
Page 145 · click to enlarge
Page 145

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 2000000 Forwarding 00:00:00:20:06:25:ed:89 00:09 10 TP(10/100) 128 2000000 Disabled 00:0a 11 TP(10/100) 128 2000000 Disabled 00:0b 12 TP(10/100) 128 2000000 Disabled 00:0c 13 TP(10/100) 128 200000 Forwarding 00:00:00:20:06:25:ed:89 00:0d 14 TP(10/100) 128 2000000 Disabled 00:0e 15 TP(10/100) 128 2000000 Disabled 00:0f 16 TP(10/100) 128 2000000 Disabled 00:10 Magnum6K25(rstp)## forceversion rstp Error: Force Version already set to Normal RSTP Magnum6K25(rstp)## forceversion stp Magnum6K25(rstp)## show-forceversion Force Version : Force to STP only Magnum6K25(rstp)## show stp config RSTP CONFIGURATION Rapid STP/STP Enabled(Global) : YES RSTP/STP Enabled Ports : 9,10,11,12,13,14,15,16 Protocol : Force to STP only Bridge ID : 00:00:00:20:06:25:ed:89 Bridge Priority : 0 Bridge Forward Delay : 15 Bridge Hello Time : 02 Bridge Max Age : 20 Root Port : 0 Root Path Cost : 0 Designated Root : 00:00:00:20:06:25:ed:89 Designated Root Priority : 0 Root Bridge Forward Delay : 15 Root Bridge Hello Time : 02 Root Bridge Max Age : 20 Topology Change count : 0 Time Since topology Chg : 100 Magnum6K25(rstp)## forceversion rstp Magnum6K25(rstp)## show-forceversion Force Version : Normal RSTP Magnum6K25(rstp)## show stp config RSTP CONFIGURATION

“forceversion” can be used for compatibility with STP devices. In this example, the switch is forced to STP mode.

Using forceversion the switch is now operating using RSTP. Note the “show stp config” command also indicates the switch protocol is RSTP.

Page 146 of the GarrettCom MNS-6K user manual — RSTP concepts
Page 146 · click to enlarge
Page 146

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Rapid STP/STP Enabled(Global) : YES RSTP/STP Enabled Ports : 9,10,11,12,13,14,15,16 Protocol : Normal RSTP Bridge ID : 00:00:00:20:06:25:ed:89 Bridge Priority : 0 Bridge Forward Delay : 15 Bridge Hello Time : 02 Bridge Max Age : 20 Root Port : 0 Root Path Cost : 0 Designated Root : 00:00:00:20:06:25:ed:89 Designated Root Priority : 0 Root Bridge Forward Delay : 15 Root Bridge Hello Time : 02 Root Bridge Max Age : 20 Topology Change count : 0 Time Since topology Chg : 141 Magnum6K25(rstp)## show-timers Forward Delay Timer : 15 sec Hello Timer : 2 sec Max Age : 20 sec Magnum6K25(rstp)## show stp ports RSTP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 2000000 Forwarding 00:00:00:20:06:25:ed:89 00:09 10 TP(10/100) 128 2000000 Disabled 00:0a 11 TP(10/100) 128 2000000 Disabled 00:0b 12 TP(10/100) 128 2000000 Disabled 00:0c 13 TP(10/100) 128 200000 Forwarding 00:00:00:20:06:25:ed:89 00:0d 14 TP(10/100) 128 2000000 Disabled 00:0e 15 TP(10/100) 128 2000000 Disabled 00:0f 16 TP(10/100) 128 2000000 Disabled 00:10 Magnum6K25(rstp)## priority port=13 value=100 Magnum6K25(rstp)## show stp ports RSTP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 2000000 Forwarding 00:00:00:20:06:25:ed:89 00:09 10 TP(10/100) 128 2000000 Disabled 00:0a 11 TP(10/100) 128 2000000 Disabled 00:0b

Page 147 of the GarrettCom MNS-6K user manual — RSTP concepts
Page 147 · click to enlarge
Page 147

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

12 TP(10/100) 128 2000000 Disabled 00:0c 13 TP(10/100) 100 200000 Forwarding 00:00:00:20:06:25:ed:89 00:0d 14 TP(10/100) 128 2000000 Disabled 00:0e 15 TP(10/100) 128 2000000 Disabled 00:0f 16 TP(10/100) 128 2000000 Disabled 00:10 Magnum6K25(rstp)## cost port=13 value=250000 Magnum6K25(rstp)## show stp ports RSTP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 2000000 Forwarding 00:00:00:20:06:25:ed:89 00:09 10 TP(10/100) 128 2000000 Disabled 00:0a 11 TP(10/100) 128 2000000 Disabled 00:0b 12 TP(10/100) 128 2000000 Disabled 00:0c 13 TP(10/100) 100 250000 Forwarding 00:00:00:20:06:25:ed:89 00:0d 14 TP(10/100) 128 2000000 Disabled 00:0e 15 TP(10/100) 128 2000000 Disabled 00:0f 16 TP(10/100) 128 2000000 Disabled 00:10 Magnum6K25(rstp)## port port=9 status=disable Magnum6K25(rstp)## show stp ports RSTP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 2000000 NO STP 00:09 10 TP(10/100) 128 2000000 Disabled 00:0a 11 TP(10/100) 128 2000000 Disabled 00:0b 12 TP(10/100) 128 2000000 Disabled 00:0c 13 TP(10/100) 100 250000 Forwarding 00:00:00:20:06:25:ed:89 00:0d 14 TP(10/100) 128 2000000 Disabled 00:0e 15 TP(10/100) 128 2000000 Disabled 00:0f 16 TP(10/100) 128 2000000 Disabled 00:10 Magnum6K25(rstp)## port port=9 status=enable Magnum6K25(rstp)## show stp ports RSTP Port Configuration Port# Type Priority Path Cost State Des. Bridge Des. Port 09 TP(10/100) 128 2000000 Forwarding 00:00:00:20:06:25:ed:89 00:09 10 TP(10/100) 128 2000000 Disabled 00:0a

Page 148 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 148 · click to enlarge
Page 148

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

11 TP(10/100) 128 2000000 Disabled 00:0b 12 TP(10/100) 128 2000000 Disabled 00:0c 13 TP(10/100) 100 250000 Forwarding 00:00:00:20:06:25:ed:89 00:0d 14 TP(10/100) 128 2000000 Disabled 00:0e 15 TP(10/100) 128 2000000 Disabled 00:0f 16 TP(10/100) 128 2000000 Disabled 00:10 Magnum6K25(rstp)## timers forward-delay=20 hello=5 age=30 Successfully set the bridge time parameters Magnum6K25(rstp)## show stp config RSTP CONFIGURATION Rapid STP/STP Enabled(Global) : YES RSTP/STP Enabled Ports : 9,10,11,12,13,14,15,16 Protocol : Normal RSTP Bridge ID : 00:00:00:20:06:25:ed:89 Bridge Priority : 0 Bridge Forward Delay : 20 Bridge Hello Time : 05 Bridge Max Age : 30 Root Port : 0 Root Path Cost : 0 Designated Root : 00:00:00:20:06:25:ed:89 Designated Root Priority : 0 Root Bridge Forward Delay : 20 Root Bridge Hello Time : 05 Root Bridge Max Age : 30 Topology Change count : 0 Time Since topology Chg : 567 Magnum6K25(rstp)## exit Magnum6K25# FIGURE 83 – Configuring RSTP on MNS-6K

List of commands in this chapter

Syntax set stp type=<stp|rstp> - Set the switch to support RSTP or change it back to STP. Need to save

and reboot the switch after this command Syntax rstp – enter the RSTP configuration mode Syntax rstp <enable|disable> - enable RSTP – by default, this is disabled and has to be manually

activated

Page 149 of the GarrettCom MNS-6K user manual — RSTP concepts
Page 149 · click to enlarge
Page 149

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax port port=<number|list|range> [status=<enable|disable>]

[migration=<enable>] [edge=<enable|disable>] [p2p=<on|off|auto>] - set the port type for RSTP

Example port port=<number|list|range> p2p= off - Set the “point-to-point” value to off on

all ports that are connected to shared LAN segments (i.e. connections to hubs). The default value is auto. P2P ports would typically be end stations or computers on the network Example port port=<number|list|range> edge=enable – enable all ports connected to

other hubs, bridges and switches as edge ports Example port port=<number|list|range> migration=enable – set this for all ports

connected to other devices such as hubs, bridges and switches known to support IEEE 802.1d STP services, but cannot support RSTP services Syntax show active-stp – status whether STP or RSTP is running Syntax show stp <config|ports> - display the RSTP or STP parameters

Syntax forceversion <stp|rstp> - set the STP or RSTP compatibility mode Syntax show-forceversion - the current force version Syntax show-timers - show the values of the timers set for RSTP Syntax priority [port=<number|list|range>] value=<0-255 | 0-65535> - specifies the port or

switch level priority. When a port(s) are specified the priority is associated with ports and their value is 0- 255. If no ports are specified, then the switch (bridge) priority is specified and its value is 0-65535 Syntax cost port=<number|list|range> value=<0-65535> - cost is specific to a port and the port(s)

have to be specified Syntax port port=<number|list|range> status=<enable|disable> - specific ports may not need to

participate in STP process. These ports typically would be end-stations. If you are not sure – let MNS-6K software make the decisions

Syntax timers forward-delay=<4-30> hello=<1-10> age=<6-40> - change the STP Forward delay,

Hello timer and Aging timer values

Page 150 of the GarrettCom MNS-6K user manual — Speed up recovery from faults in Ethernet networks
Page 150 · click to enlarge
Page 150

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E Chapter 12

12 – RS-Ring™, S-Ring™ and LinkLoss-Learn™ (LLL)

Speed up recovery from faults in Ethernet networks

order to participate in S-Ring configurations. S

-Ring and RS-Ring use ring topology to provide fast recovery from faults. These are based on industry standard STP and RSTP technologies. These technologies have been adapted to ring recovery applications by GarrettCom Inc. and these rings are called S-Ring. In addition, LLL enables a switch to rapidly re-learn MAC addresses in

In the last two chapters we looked at how RSTP or STP can be used to bring resiliency to a meshed network. This chapter’s focus is to look at ring topologies and how these topologies can be used to provide faster recovery times than what STP or RSTP can offer. Both RSTP and STP are industry standard protocols and can be used with networking switches from different vendors. LLL triggers action on the device supporting LLL when a connection is broken or there is loss of the link signal on a ring port. LLL can be used with S-Ring on managed switches such as the GarrettCom Magnum 6K family of switches. LLL can also be used on managed switches such as Magnum 6K family of switches, Magnum mP62 as well as on unmanaged switches such as ESD42 switches. Note that LLL can also be used with non-ring topologies (such as mesh topologies) using RSTP or STP where it does the necessary actions for fault recovery (such as re-learn addresses) in case of a link failure. S-Ring is a ring technology using the GarrettCom MNS-6K software. In a S-Ring, a switch is designated as a “Ring Manager”. Devices in a S-Ring can be managed switches such as the Magnum 6K family of switches, other managed switches such as Magnum mP62 or unmanaged switches such as ESD42 or even hubs which leverages LLL. S-Ring is a licensed product from GarrettCom Inc. GarrettCom Inc. also licenses this technology to other companies who are interested in implementing the resiliency capabilities offered by S-Ring. RS-Ring provides superior recovery times from failures. It works when

Page 151 of the GarrettCom MNS-6K user manual — j
Page 151 · click to enlarge
Page 151

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

  • The ring is made up of devices which are managed switches only from Magnum 6K family of switches
  • Each of the switches in the ring topology are configured for RSTP
  • The RS-Ring product license key is configured on each switch in the ring

S-Ring and LLL concepts

j

S-Ring is built upon networking software standards such as IEEE 802.1d Spanning Tree Protocol (STP) or Rapid Spanning Tree Protocol (RSTP) based on IEEE 802.1w. The purpose of S-Ring is to define two ports which participate in the RSTP/STP tree structure in a ring topology as opposed to a meshed topology. S-Ring running on the ring manager switch leverages this capability to recover quickly from fault situations. The recovery times for S-Ring based networks are within a few hundred milliseconds. Recovery time for STP devices is in tens of seconds (typically 30-50 seconds in most networks) or sub second to a few seconds for RSTP networks. The biggest advantage of S-Ring, besides the fast recovery time, is the defined ring topology which makes the network manageable. S-Ring can also be an overall lower cost solution as there are hubs as well as switches which can be used in the ring.

In the Magnum 6K family of switches as well as in other unmanaged switches such as the ESD42, a feature called Link-Loss-Learn™ (LLL) can be activated to immediately flush its address buffer and relearn the MAC addresses that route packets around the fault. This procedure, which is similar to switch initialization, occurs within milliseconds, resulting in fast ring recovery. An S-Ring implementation watches for link-loss as well as for STP/RSTP BPDU packet failures and responds to whichever occurs first. In most instances the link-loss will be detected faster than the two-second interval at which the BPDU packets are successfully passed around the ring. Typical ring recovery times using S-Ring software and mP62 edge switches with the LLL feature enabled on the ring ports is less than 250 milliseconds, even with 50 or more Magnum 6K family of switches in a ring structure. Without LLL activation, the Magnum 6K family of switches address buffer aging time (5 minutes default) could be the gating factor in ring recovery time. LLL is used on S-Ring and helps speed up the ring recovery time. S-Ring operates from specifically defined port pairs that participate in a ring- topology. Multiple rings of different pairs on the same switch are also supported; however, intersecting rings or a “ring of rings” or “overlapping rings” is not supported in the current version. While S-Ring builds upon the foundation of RSTP or STP, S-Ring offers an additional topology option to network architects. The two ends of a ring must be connected to two ports in a Magnum 6K Switch that is enabled with the S-Ring software. The end points of the ring provide an alternate path to reach the switch that has failed. The in-out pairs of the ports to other devices in the ring have to be enabled with LLL. Some items to be aware of with S-Ring are as follows:

Page 152 of the GarrettCom MNS-6K user manual — j
Page 152 · click to enlarge
Page 152

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

1. The S-Ring feature is a separately licensed module for the MNS-6K software package. This module must be enabled by means of a software key 2. Only one switch is the “Ring Master”. That switch has S-Ring Software authorized (enabled) for that device. Thus only one license key is needed per ring (and not per switch) 3. There can be multiple S-Rings on a given Magnum 6K switch. There can be multiple ring topologies in a network. Each ring has to be a separate ring. Ring of rings or overlapping rings are not supported at this time 4. S-Ring topologies support one failure in the network. A second failure may create isolated network islands 5. At least one untagged VLAN must be available for the BPDU’s to propagate through the network to update RSTP/STP status 6. S-Ring faults can be software signaled to alarm contacts.

j

Today, more and more situations demand a network to be built using managed switches. These situations also demand a faster recovery time in case of a network failure. The topologies have to be simple for maintenance and other reasons. In these situations, a ring topology provides fault tolerance with the simplicity. RS-Ring feature can be used on managed Magnum 6K family of switches. RS-Ring provides the simple ring topology and provides faster recovery times than S-Ring or STP/RSTP.

RS-Ring is built upon networking software standards such as Rapid Spanning Tree Protocol (RSTP) based on IEEE 802.1w. RS-Ring defines two ports on each switch which participates in the ring topology and works with the RSTP tree structure. RS- Ring requires RSTP to be configured across all switches and uses the underlying RSTP protocol to provide simplicity in configuration as well as rapid recovery in the RS-Ring topology. The recovery times for RS-Ring based networks are within milliseconds. While the recovery time for STP devices is in tens of seconds (typically 30 seconds in most networks) or sub second to a few seconds for RSTP networks, RS-Ring offers recovery times typically in less than 100 milliseconds. The biggest advantage of RS-Ring, besides the fast recovery time, is the defined topology which makes the network manageable. RS-Ring is configured on Magnum 6K family of switches and requires RSTP to be enabled on all switches participating in the RS- Ring. RS-Ring cannot be used in a multi-vendor environment. RS-Ring operates from specifically defined port pairs that participate in a ring- topology. Each of the two ends of a ring must be connected to two ports in a Magnum 6K Switch that is enabled with the RS-Ring software. The end points of the ring provide an alternate path to reach the switch that has failed. Some items for using RS-Ring are as follows:

1. Faster recover times than S-Ring or RSTP are needed by the network 2. The RS-Ring feature is a separately licensed module for the MNS-6K software package. This module must be enabled by means of a software key. 3. The same key can be used for either S-Ring or RS-Ring

RS-Ring concepts

Page 153 of the GarrettCom MNS-6K user manual — When to use RS-Ring vs S-Ring
Page 153 · click to enlarge
Page 153

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

4. The same license key needs to be configured for each switch on the ring and RS-Ring capability has to be enabled on all switches (and hence all the devices in the ring have to be a managed Magnum 6K switches) 5. RS-Ring topologies support one failure in the network. The second failure may create isolated network islands 6. RSTP has to be enabled on all Magnum 6K switches in the ring 7. At least one untagged VLAN must be available for the BPDU’s to propagate through the network to update RSTP status.

When to use RS-Ring vs S-Ring

RS-Ring or S-Ring provides resiliency in the network. So does RSTP and STP. The general guidelines for making a decision as to whether to use S-Ring or RS-Ring or for that matter, RSTP or STP, matters a lot on some key criteria, some of which are listed below.

  • Speed – RS-Ring offers substantially faster recovery times compared to S-Ring. While the recovery time will vary on factors such as number of nodes in a ring, lengthof the ring etc., on an average, RS-Ring typically recovers in less than 100 mSec vs 300 mSec for S-Ring.
  • Cost – RS-Rings and S-Rings are licensed features. S-Ring requires at least one device in the network should be a managed switch. RS-Ring requires all devices in the ring should be a managed Magnum 6K switches. So while the recovery times are faster for RS-Ring, the cost of building such a ring may be higher
  • Ring Topology – multiple rings may be implemented with S-Ring running on one managed Magnum 6K switch. Only one RS-Ring per Magnum 6K switch can be configured 4 .
  • Managed Switches – RS-Ring requires all devices in the ring are managed Magnum 6K family of switches. If there are non managed devices, RS-Ring cannot be used.

4 It is technically possible to have S-Ring and RS-Ring on the same Magnum 6K Switch. GarrettCom Inc. does not recommend nor support such configurations.

Page 154 of the GarrettCom MNS-6K user manual — Recovery decision
Page 154 · click to enlarge
Page 154

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Comparing resiliency methods

So far we have briefly covered S-Ring with LLL, RS-Ring, RSPT as well as STP. The table below summarizes some decision criteria on selecting RSPT vs STP vs S-Ring (and LLL) vs RS-Ring. RS-Ring S-Ring with LLL RSTP STP License Same license key as S-Ring. One license key needs to be enabled on each Magnum 6K switch

A license key is needed. One key per ring manager switch

Spanning Tree Works with RSTP Works with RSTP or STP devices

Devices supported

Managed Magnum 6K family of switches

Managed or certain non managed Magnum switches. Requires at least one Magnum 6K switch as ring manager

Recovery decision

Distributed across all switches in the ring. Works with RSTP in each switch

Centralized to “Ring Manager”. LLL provides triggers to recomputed topology for ring members. Also works with RSTP or STP.

Typically done using BPDU. Can take time.

Typically done using BPDU. Can take time.

Topology Single ring, multiple rings, no overlapping rings or ring of rings

Mesh topology – can have multiple paths Interoperability Works with managed Magnum 6K family of switches

Single ring, multiple rings, no overlapping rings or ring of rings

Mesh topology – can have multiple paths

Works with managed 6K family of switches, other managed switches such as mP62 and non managed switches as well as some hubs

Wide range of products, including other vendor products

Wider range of products, including other vendor products

Recovery time Fastest Fast Medium – sub second to a few seconds

Slow – in tens of seconds

Included in MNS-6K · Included in MNS-6K · Many Many

Page 155 of the GarrettCom MNS-6K user manual — RSTP/STP Operation without RSRing or S-Ring
Page 155 · click to enlarge
Page 155

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

RS-Ring S-Ring with LLL RSTP STP Resiliency Fast recovery from a single point of failure. No centralized decision making

Multiple points of failure – each connected node can be in stand-by Software Cost Licensed per ring Licensed per ring Included in MNS-6K

Fast recovery from a single point of failure. Ring Master is responsible for decision making

Multiple points of failure – each connected node can be in stand-by

Included in MNS-6K Hardware cost Managed 6K switches only

Many choices available, making it cost effective Software Alarm Not available at this time

One Managed 6K per ring. Multiple choices for members of the ring

Many choices available, making it cost effective

Ring Size 50+ nodes 50+ nodes NA NA Dual-Homing Supports dual - homing to members in the ring

Supports dual-homed device to devices in the network

Supports dual-homing to members in the ring

Supports dual- homed device to devices in the network

RSTP/STP Operation without RSRing or S-Ring

S-Ring supports non managed switches as long as LLL capability is supported on that switch. A ring is a special form of mesh network topology. The two top-of-the-ring ports form an otherwise-illegal redundant path, and standard RSTP/STP causes one of these two ports to block incoming packets in order to enable normal Ethernet traffic flow. All ring traffic goes through the non-blocking port for normal LAN operation. This port is designated Forwarding Port. Meanwhile, there is a regular flow of status-checking multi-cast packets (called BPDUs or Bridge Protocol Data Units) sent out by RSTP/STP that move around the ring to show that things are functioning normally.

Yes No No

Page 156 of the GarrettCom MNS-6K user manual — Traffic
Page 156 · click to enlarge
Page 156

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

GarrettCom MNS-6K — RS-Ring concepts diagram (page 156)
Fig. 10 · RS-Ring concepts

Traffic

Traffic

BPDU

BPDU

Forwarding Port

Forwarding Port

Blocking Port

Blocking Port

FIGURE 84 – Normal RSTP/STP operations in a series of switches. Note – this normal status is designated RING_CLOSED

This normal status is designated as RING_CLOSED. Operations will continue this way indefinitely until a fault occurs. A fault anywhere in the ring will interrupt the flow of standard RSTP/STP status-checking BPDU packets, and will signal to RSTP/STP that a fault has occurred. According to the standard RSTP/STP defined sequence, protocol packets are then sent out, gathered up and analyzed to enable RSTP/STP to calculate how to re-configure the LAN to recover from the fault. After the standard RSTP/STP reconfiguration time period (typically 20 to 30 seconds), the RSTP/STP analysis concludes that recovery is achieved by changing the blocking port of the ring port-pair to the forwarding state.

Intentionally left blank

Page 157 of the GarrettCom MNS-6K user manual — RSTP/STP Operation with S-Ring
Page 157 · click to enlarge
Page 157

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

GarrettCom MNS-6K — RS-Ring concepts diagram (page 157)
Fig. 11 · RS-Ring concepts

Traffic

Traffic

Traffic

Traffic

BPDU

BPDU

Forwarding Port

Forwarding Port

Forwarding Port

Forwarding Port

BPDU

BPDU

FIGURE 85 – A fault in the ring interrupts traffic. The blocking port now becomes forwarding so that traffic can reach all switches in the network Note – the mP62 as well as the ESD42 switches support LLL and can participate in S-Ring as an access switch When this change is made by RSTP/STP and both of the ring manager switch’s ring ports are forwarding, the fault is effectively bypassed and there is a path for all LAN traffic to be handled properly. This abnormal status is designated RING_OPEN, and may continue indefinitely, until the ring fault is repaired. At that time, RSTP/STP will change one of the ring control ports to be a blocking port again. This recovery operation may take thirty seconds to a few minutes, depending on the number of switches and other RSTP/STP parameters in operation.

RSTP/STP Operation with S-Ring

When the Magnum 6K family of switches is used in the network and the S-Ring feature is enabled, the result of a ring-fault is the same but the recovery is faster. The S-Ring capability overrides the normal RSTP/STP analysis for the ring-pair ports of the ring manager (or ring- control) switch, providing quick recovery of the ring fault without conflicting with standard RSTP/STP. The Magnum 6K family of switches, running MNS-6K software, offer users the choice of selecting S-Ring when RSTP or STP is configured and in use. For the S-Ring, the user must select two ports of one 6K switch to operate as a pair in support of each Ethernet ring, and attach to the two “ends” of each ring as it comes together at the ring control switch.

Page 158 of the GarrettCom MNS-6K user manual — RS-Ring concepts
Page 158 · click to enlarge
Page 158

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

FIGURE 86 – More than one S-Ring pair can be selected and more than one S-Ring can be defined per switch. Note – the mP62 as well as the ESD42 switches support LLL and can participate in S-Ring as an access switch

More than one S-Ring port-pair may be selected per ring control switch. Each port-pair will have its own separate attached ring, and each port-pair operates on faults independently. The port-pairs may be of any media type, and the media type does not have to be the same for the pair. With the Magnum 6K family of switches, a port operating at any speed (10Mb, 100Mb, Gb) may be designated as part of an S-Ring port-pair (or RS-Ring port pair) ensuring proper Ethernet configuration of the ring elements. After selecting a port-pair for a ring, the manager or administrator enables S-Ring (on the selected port-pairs via S-Ring software commands. One command (enable / disable) turns S- Ring on and off. Another command adds / deletes port- pairs. Other commands provide for status reporting on the ring. The MNS-6K software package provides for remote operation, access security, event logs, and other industry-standard managed network capabilities suitable for industrial applications requiring redundancy. When S-Ring is enabled for a port-pair, fault detection and recovery are armed for the associated ring. The standard RSTP/STP functions are performed by the Magnum 6K family of switches for other ports in the same manner as they would be without S-Ring enabled, when operating in the RING_CLOSED state. During this state, RS-Ring or S-Ring is also watching the flow of the BPDU packets that move around the ring between the designated part-pair. The extra capability of S-Ring comes into play when a fault occurs. When the flow of BPDU packets around the ring is interrupted (or when Link-Loss is sensed on one of the ports of the ring port-pair by S-Ring), S-Ring quickly acts to change the blocking port’s state to forwarding. No waiting for STP analysis. No waiting for RSTP analysis. No checking for other possible events. No other ports to look at. No 30-second delay before taking action. S- Ring or RS-Ring takes immediate corrective action for quick recovery from the fault in the ring. The ring becomes two strings topologically, as shown above, and there is a path

Show 4 more labels / short text on this page
Ring 1 · Ring 1 · Ring 2 · Ring 2
Page 159 of the GarrettCom MNS-6K user manual — Ring learn features
Page 159 · click to enlarge
Page 159

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

through the two strings for all normal LAN traffic to move as needed to maintain LAN operations. When the fault is cured, the re-emergence of the ring structure enables the BPDU packets to flow again between the ring’s port-pair. This is recognized by S-Ring (and RSTP/STP) as well as by RS-Ring (and RSTP) , and one of the ports in the ring’s port pair is changed to the blocking state. S-Ring takes the recovery action immediately, not waiting for the 30-second STP analysis. Rings are simple structures. Either one port of a pair is forwarding or both are. Not complicated; not much to go wrong. A Link-loss on one of the Magnum 6K Switch’s ring ports is an alternative trigger for S-Ring to initiate fault recovery. The Link-loss trigger almost always comes quicker after a fault (a few milliseconds) than the loss of a BPDU packet which is gated by the standard STP 2- second “hello time” interval. So the Link-loss trigger will almost always provide faster fault detection and faster recovery accordingly.

LLL with S-Ring

The Link-Loss-Learn™ feature, available on Magnum 6K family of switches can significantly reduce switch address memory decay time, resulting in more rapid reconfiguration. With Link-Loss-Learn (LLL), Magnum 6K family switches in a ring can flush their address memory buffer and quickly re-learn where to send packets, enabling them to participate in a very quick recovery or restoration. Note that a Link-loss on any Magnum 6K Switch port somewhere in the ring is an alternative trigger for S-Ring to act for either fault recovery or ring restoration. The interruption (or the restoration) of the flow of BPDU packets is one trigger, link-loss is another, and action is taken by S-Ring based on whichever occurs first.

Ring learn features

One of the S-Ring software commands, “s-ring learn”, causes the scanning of all ports in the Magnum 6K family of switches for the presence of rings. This command can be a handy tool in setting up the S-Ring product for correct initial operation. During a ring-learn scan, if any port receives a BPDU packet that was also originated by the same switch, the source and destination ports are designated as a ring port-pair and they are automatically added to the S- Ring port-pair list for that 6K Switch. The user can enable or disable ports pairs that are on the S-Ring list by CLI commands in order to exercise final control if needed. This feature is not available with RS-Ring.

Page 160 of the GarrettCom MNS-6K user manual — Configuring S-Ring
Page 160 · click to enlarge
Page 160

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Configuring S-Ring

S-Ring is a licensed software feature from GarrettCom Inc. Before using the S-Ring capabilities; authorize the use of the software with the license key. To obtain the license key, please contact GarrettCom Inc. Sales (for purchasing the S-Ring feature) or Technical Support (to obtain the 12 character key.) If the S-Ring capability was purchased along with the switch, the software license code will be included with the switch. Syntax authorize <module> key=<security key> - activate the S-Ring capabilities. Don’t forget to use the “save” command to save the key

In the example below – STP is used to show how S-Ring is setup. S-Ring will also work with RSTP. If RSTP is used, GarrettCom Inc. recommends using RS-Ring instead.

Magnum6K25# authorize s-ring key=abc123456789 S-RING Module Successfully Authorized Please Save Configuration. Magnum6K25# save Saving current configuration Configuration saved Saving current event logs Event logs saved Magnum 6K25# reboot Proceed on rebooting the switch? [ 'Y' or 'N' ] Y Do you wish to save current configuration? [ 'Y' or 'N' ] Y Saving current configuration Configuration saved Rebooting now... FIGURE 87 – Activating S-Ring on the switch

Since S-Ring uses RSTP/STP, STP has to be activated and enabled. Please refer to the Chapter on Spanning Tree Protocol (STP) for more information. Some of the commands are repeated here for clarity. Using S-Ring with multiple switches, it is recommended to do the following:

1. On the switch which is the root node, authorize the use of S-Ring software 2) On the switch which is the root node or where the top of the ring ports are configured, enable STP 3) On the root node enable S-Ring and add the necessary ports as S-Ring ports 4) On all other switches (except the root node), disable STP 5) On all other switches (except the root node), enable LLL
Page 161 of the GarrettCom MNS-6K user manual — RS-Ring concepts
Page 161 · click to enlarge
Page 161

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Ports associated with S-Ring should have the following settings

  • Auto negotiation - disable
  • Speed - Fixed
  • Same Speed
  • Same Duplex and
  • LLL - enable The necessary commands are Syntax stp – STP Configuration mode Syntax stp <enable|disable> - Start (Enable) or stop (Disable) STP Syntax set stp type=<stp|rstp> - set the spanning tree protocol to be IEEE 802.1d or 802.1w

(Spanning Tree Protocol or Rapid Spanning Tree Protocol) Syntax show active-stp – Display which version of STP is currently active Syntax show s-ring – show the status of S-Ring status and configuration Syntax s-ring <enable|disable> - enable or disable S-Ring capabilities Syntax s-ring learn – start the learning process to discover the ring and the ports which make up the S-

Ring Syntax s-ring add port=<port1,port2> - define ports which make up the S-Ring ports. Note as discussed earlier, you can create multiple S-Rings on a switch Syntax s-ring del port=<port1,port2> - remove the switch from S-Ring topology by eliminating the end ports on the switch

Magnum6K25(stp)## show s-ring S-Ring Status: sRing Status: DISABLED Port 1 Port 2 Status Magnum6K25(stp)## s-ring enable S-RING Enabled. Magnum6K25(stp)## show s-ring S-Ring Status: sRing Status: ENABLED

Page 162 of the GarrettCom MNS-6K user manual — RS-Ring concepts
Page 162 · click to enlarge
Page 162

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Port 1 Port 2 Status Magnum6K25(stp)## s-ring add port=1,7 Ports 1 and 7 Configured for sRing Operation Magnum6K25# show s-ring Magnum Ring Status: sRing Status: ENABLED Port 1 Port 2 Status 1 7 CLOSED FIGURE 88 – S-Ring configuration commands for root switch

If the BPDU stream is broken, or it finds the Link-Loss-Learn signal, the system will immediately force STP to put both ports in forwarding mode. Should that happen, the ring status will be displayed as “OPEN” If the ring sees BPDUs not belonging to itself on any of the ports, it will set the ring to “UNKNOWN” state, and stop all ring activity on that ring.

The ring activity has several timers and safeguards to prevent erroneous operation. Ring faults are not expected to happen in quick successions. If the ring system sees a sequence of changes in the duration of a less than a second each, it will temporarily ignore the signals and leave STP to reconfigure the ring (network) using the normal IEEE 802.1d algorithms. With S-Ring it is also critical to setup and configure Link-Loss-Learn as the S-ring can recover from fault situations a lot faster. For configuring LLL, use the commands listed below. Syntax lll <enable|disable> - enable or disable LLL on the switch

If STP is enabled, Link Loss Learn will not work even though it was enabled. LLL is not enabled on the root node. Syntax lll add port=<port|list|range> - enable LLL on the list of specified ports Syntax lll del port=<port|list|range> - disable LLL on the list of specified ports Syntax show lll – display the status of LLL

Page 163 of the GarrettCom MNS-6K user manual — RSTP Operation with RS-Ring
Page 163 · click to enlarge
Page 163

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# stp Magnum6K25(stp)## lll enable Link-Loss-Learn Enabled. Magnum6K25(stp)## lll add port=1,2,3 Added Ports: 1,2,3 Magnum6K25(stp)##show lll Link-Loss-Learn Status: LLL Status: ENABLED LLL Enabled on Ports: 1,2,3 Magnum6K25(stp)## lll del port=2,3 Deleted Ports: 2,3 Magnum6K25(stp)## lll disable Link-Loss-Learn Disabled. FIGURE 89 – Link Loss Learn (LLL) setup. Setup LLL on ports connected to other switches participating in S-Ring

RSTP Operation with RS-Ring

When the managed Magnum 6K family of switches is used in the network and the RS-Ring feature is enabled5, each of the managed Magnum 6K switch knows of the neighbor and the related associations and topologies. The RS-Ring capability overrides the normal RSTP analysis for the ring-pair ports on each switch, providing quick recovery of the ring fault without conflicting with standard RSTP. Unlike S-Ring, the decision is made by each individual switch and not by the ring master. For RS-Ring, the user must select the two ports (port pairs) and enable RS-Ring on each of the switches in the ring.

5 Note – S-Ring license also enables use of RS-Ring

Page 164 of the GarrettCom MNS-6K user manual — RS-Ring concepts
Page 164 · click to enlarge
Page 164

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Ring 1 Ring 2

Ring 1 Ring 2

FIGURE 90 – More than one RS-Ring cannot be defined per managed Magnum 6K switch. Note – unmanaged switches cannot participate in RS-Ring.

The port-pairs may be of any media type, and the media type does not have to be the same for the pair. With the Magnum 6K family of switches, a port operating at any speed (10Mb, 100Mb, Gb) may be designated as part of a RS-Ring port pair ensuring proper Ethernet configuration of the ring elements. After selecting a port-pair for a ring, the manager or administrator enables RS-Ring on the selected port-pairs via RS-Ring software commands. One command (enable / disable) turns RS-Ring on and off. Another command adds / deletes port- pairs. Other commands provide for status reporting on the ring. The MNS-6K software package provides for remote operation, access security, event logs, and other industry-standard managed network capabilities suitable for industrial applications requiring redundancy. When RS-Ring is enabled for a port-pair, fault detection and recovery are armed for the associated ring. The standard RSTP functions are performed by the Magnum 6K family of switches for other ports in the same manner as they would be without RS-Ring enabled, when operating in the RING_CLOSED state. During this state, RS-Ring is also watching the flow of the BPDU packets that move around the ring between the designated part-pair. The extra capability of RS-Ring comes into play when a fault occurs. When the flow of BPDU packets around the ring is interrupted RS-Ring quickly acts to change the blocking port’s state to forwarding. No waiting for RSTP analysis. No checking for other possible events. No other ports to look at. No 30-second delay before taking action. RS-Ring takes immediate corrective action for quick recovery from the fault in the ring. The ring becomes two strings topologically, and there is a path through the two strings for all normal LAN traffic to move as needed to maintain LAN operations. When the fault is cured, the re-emergence of the ring structure enables the BPDU packets to flow again between the ring’s port-pair. This flow of packets may take as long as 6 seconds in most situations. This is recognized by RS-Ring as well as by RSTP and one of the ports in the defined ring port pair is changed to the blocking state. RS-Ring takes the recovery action immediately, not waiting for the 30-second STP analysis.

Page 165 of the GarrettCom MNS-6K user manual — Configuring RS-Ring
Page 165 · click to enlarge
Page 165

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Rings are simple structures. Either one port of a pair is forwarding or both are. Not complicated; not much to go wrong.

Configuring RS-Ring

RS-Ring is a licensed software feature from GarrettCom Inc. Before using the RS-Ring capabilities; authorize the use of the software with the S-Ring license key. The same license key is used for either the S-Ring or RS-Ring. To obtain the license key, please contact GarrettCom Inc. Sales (for purchasing the S-Ring feature) or Technical Support (to obtain the 12 character key.) If the S-Ring capability was purchased along with the switch, the software license code will be included with the switch. Syntax authorize <module> key=<security key> - activate the RS-Ring (or S-Ring) capabilities. Don’t forget to use the “save” command to save the key

Magnum6K25# authorize s-ring key=abc123456789 S-RING Module Successfully Authorized Please Save Configuration. Magnum6K25# save Saving current configuration Configuration saved Saving current event logs Event logs saved FIGURE 91 – Activating RS-Ring on the switch

Since RS-Ring uses RSTP, RSTP has to be activated and enabled. Please refer to the Chapter on Rapid Spanning Tree Protocol (RSTP) for more information. Some of the commands are repeated here for clarity. Using RS-Ring with multiple switches, it is recommended to do the following:

1) On all switches in the ring topology, authorize the use of RS-Ring software 2) On all the switches in the ring, enable RSTP 3) On all the switches in the ring designate the ports which make the ring pair 4) Only the ports on the RS-Ring must be enabled with RS-Ring capability 5) DO NOT enable S-Ring and RS-Ring in a given ring at the same time. 6) Enable RS-Ring on each switch Ports associated with RS-Ring should have the following settings

  • Same Speed - 100Mbps connection provides faster recovery than 10 Mbps networks
  • Same Duplex capabilities - The necessary commands are Syntax rstp – STP Configuration mode
Page 166 of the GarrettCom MNS-6K user manual — RS-Ring concepts
Page 166 · click to enlarge
Page 166

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax rstp <enable|disable> - Start (Enable) or stop (Disable) STP Syntax set stp type=<stp|rstp> - set the spanning tree protocol to be IEEE 802.1w (Rapid

Spanning Tree Protocol) Syntax show active-stp – Display which version of STP is currently active Syntax show rs-ring – show the status of RS-Ring status and configuration Syntax rs-ring <enable| disable> - enable or disable RS-Ring capabilities Syntax rs-ring add port=<port1,port2> - define ports which make up the RS-Ring ports. Note as discussed earlier, you can create multiple RS-rings on a switch Syntax rs-ring del port=<port1,port2> - remove the switch from RS-Ring topology by eliminating the end ports on the switch

Magnum 6K25# authorize s-ring key=BABABABABABAB S-RING Module Successfully Authorized Please Save Configuration. Magnum 6K25# save Saving current configuration Configuration saved Saving current event logs Event logs saved Magnum 6K25# show rs-ring RS-RING status : Disabled RS-RING set on ports : NONE Magnum 6K25# show active-stp Current Active Mode: RSTP. RSTP is Disabled. Magnum 6K25# rstp Magnum 6K25(rstp)## rstp enable Successfully set the RSTP status Magnum 6K25(rstp)## show active-stp Current Active Mode: RSTP. RSTP is Enabled. Magnum 6K25(rstp)## rs-ring add port=13,14 Added Ports: 13,14 Magnum 6K25(rstp)## show rs-ring RS-RING status : Disabled RS-RING set on ports : 13,14

Page 167 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 167 · click to enlarge
Page 167

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum 6K25(rstp)## rs-ring enable RS-RING enabled. Magnum 6K25(rstp)## show rs-ring RS-RING status : Enabled RS-RING set on ports : 13,14 Magnum 6K25(rstp)## rs-ring disable RS-RING disabled. Magnum 6K25(rstp)## rs-ring del port=13,14 Deleted Ports: 13,14 Magnum 6K25(rstp)## show rs-ring RS-RING status : Disabled RS-RING set on ports : NONE Magnum 6K25(rstp)## exit Magnum 6K25# FIGURE 92 – RS-Ring configuration commands

List of commands in this chapter

Syntax authorize <module> key=<security key> - activate the S-Ring capabilities. Don’t forget

to use the “save” command to save the key Syntax stp – STP Configuration mode Syntax stp <enable|disable> - Start (Enable) or stop (Disable) STP Syntax set stp type=<stp|rstp> - set the spanning tree protocol to be IEEE 802.1d or 802.1w

(Spanning Tree Protocol or Rapid Spanning Tree Protocol) Syntax show active-stp – Display which version of STP is currently active Syntax show s-ring – show the status of S-Ring status and configuration Syntax s-ring <enable|disable> - enable or disable S-Ring capabilities Syntax s-ring learn – start the learning process to discover the ring and the ports which make up the S-

Ring Syntax s-ring add port=<port1,port2> - define ports which make up the S-ring ports. Note as

discussed earlier, you can create multiple S-Rings on a switch

Page 168 of the GarrettCom MNS-6K user manual — RS-Ring concepts
Page 168 · click to enlarge
Page 168

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax s-ring del port=<port1,port2> - remove the switch from S-Ring topology by eliminating the

end ports on the switch Syntax lll <enable|disable> - enable or disable LLL on the switch Syntax lll add port=<port|list|range> - enable LLL on the list of specified ports Syntax lll del port=<port|list|range> - disable LLL on the list of specified ports Syntax show lll – display the status of LLL Syntax rstp – STP Configuration mode Syntax rstp <enable|disable> - Start (Enable) or stop (Disable) STP Syntax set stp type=<stp|rstp> - set the spanning tree protocol to be IEEE 802.1d or 802.1w

(Rapid Spanning Tree Protocol) Syntax show active-stp – Display which version of STP is currently active Syntax show rs-ring – show the status of RS-Ring status and configuration Syntax rs-ring <enable| disable> - enable or disable RS-Ring capabilities Syntax rs-ring add port=<port1,port2> - define ports which make up the RS-Ring ports. Note as discussed earlier, you can create multiple RS-Rings on a switch Syntax rs-ring del port=<port1,port2> - remove the switch from RS-Ring topology by eliminating the end ports on the switch

Page 169 of the GarrettCom MNS-6K user manual — j
Page 169 · click to enlarge
Page 169

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E Chapter 13

13 – Dual-Homing

Fault tolerance options for edge devices

esigning and implementing high-availability Ethernet LAN topologies in networks can be challenging. Traditionally, the choices for redundancy for edge of the network devices were too limited, too expensive, and too complicated to be considered in most networks. Redundancy at the edge of the network is greatly simplified by the using dual-homing. D

j

Ethernet LANs, dual-homing is a network topology that adds liability by allowing a device to be connected to the network by way of two independent connection points (points of attachment). One connection point is the operating connection, and the other is a standby or back-up connection that is activated in the event of a failure of the operating connection. A dual- homing switch (such as EDS42) offers two attachments into the network or two independent media paths and two upstream switch connections. In the case of the Magnum 6K family of switches, any two ports can be defined as dual-home ports to provide this level of redundancy. Loss of the Link signal on the operating port connected upstream indicates a fault in that path, and traffic is quickly moved to the standby connection to accomplish a fault recovery.

D In re · ual-Homing concepts

Page 170 of the GarrettCom MNS-6K user manual — PoE
Page 170 · click to enlarge
Page 170

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

FIGURE 93 – Dual-homing using ESD42 switch and Magnum 6K family of switches. In case of a connectivity break – the connection switches to the standby path or standby link

In those situations where the end device is a PoE device (for example, a video surveillance camera, as shown above) a Magnum 6K switch with MNS-6K can provide PoE to the end devices as well as other advantages such as IGMP, managed configuration and more. To provide the managed reliability to the end devices, dual-homing can be used with MNS-6K devices.

PoE

FIGURE 94 – Dual-homing using Magnum 6K family of switches. Note the end device (video surveillance camera) can be powered using PoE options on Magnum 6K family of switches. In case of a connectivity break – the connection switches to the standby path or standby link

Because it takes advantage of Ethernet standards, the dual-homing redundancy features of the ESD42 as well as those for MNS-6K work with any brands or models of Ethernet

Show 4 more labels / short text on this page
= Active link · = Standby Link · = Active link · = Standby Link
Page 171 of the GarrettCom MNS-6K user manual — PoE
Page 171 · click to enlarge
Page 171

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

switches upstream. With MNS-6K, the user has to define the set of ports which make up the dual-home ports.

PoE

FIGURE 95 – Using S-Ring, RS-Ring and dual-homing, it is possible to build networks resilient not only to a single link failure but also for one device failing on the network

The following points should be remembered for setting up dual-homing

  • Configure dual-homing before connecting the Ethernet connectors (cables) in the switch 6
  • Only one set of dual-homing ports can be defined per switch
  • Port types (Copper vs fiber) as well as speeds can be mixed and matched – both ports need not be identical
  • By default dual-homing is turned off – you have to enable it after the ports are defined
  • Dual-homing ports can span different modules in a switch

6 If dual homing is not configured there is a potential a loop can be created and either STP or RSTP will setup the port in the active stand-by mode. Dual-homing may not work if one of the dual-homed port is in active standby. To avoid that situation, it is recommended to configure dual-homing first.

= Active link · = Standby Link

Page 172 of the GarrettCom MNS-6K user manual — Configuring Dual-Homing
Page 172 · click to enlarge
Page 172

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Dual-Homing Modes

There are two modes in which the dual-homing works. The first one is where the ports are “equivalent” i.e. if one port fails, the other one take over, however, if the first (failed) port recovers, the active port does not switch back. The second mode of operation is primary-secondary mode. In this mode of operation, the primary port is explicitly defined and the secondary port is explicitly defined. In the primary- secondary mode of operation, if the primary fails, the secondary takes over. When the primary recovers, the secondary switches back from active state to passive state and the primary port is now the active port. The primary-secondary mode has to be explicitly setup. The primary-secondary mode of operation is only possible on managed switches such as the Magnum 6K family of switches. The primary-secondary mode of operation allows the network manager to determine on which path the packets will flow (as a default).

Configuring Dual-Homing

The following commands are used for configuring dual-homing Syntax dualhome – enter the dual-homing configuration sub-system Syntax dualhome <enable|disable> – enable or disable dual-homing Syntax dualhome add port1=<port#> port2=<port#> – dual-homing setup similar to that of unmanaged switches such as ESD42 OR Syntax dualhome add primary=<port#> secondary=<port#> – dual-homing setup as primary-secondary mode Syntax dualhome del – Delete the dual-homing setup Syntax show dualhome – Display dual-homing status The following set of commands show how dual-homing is setup. In the example below both modes of dual-homing operation is setup.

Page 173 of the GarrettCom MNS-6K user manual — Dual-Homing concepts
Page 173 · click to enlarge
Page 173

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum 6K25# dualhome ? dualhome : Configures Dual homing Usage dualhome Magnum 6K25# show dualhome Dual Homing Status : DISABLED Magnum 6K25# dualhome Magnum 6K25(dualhome)## dualhome add port1=10 port2=11 Dual Homing Ports configured Magnum 6K25(dualhome)## dualhome enable Dual Homing Enabled. Magnum 6K25(dualhome)## show dualhome Dual Homing Status : ENABLED Dual Homing Ports : 10 11 Dual Homing Active On Port : 10 Magnum 6K25(dualhome)## dualhome del Dual Homing Ports Deleted and Dual Homing Disabled. Magnum 6K25(dualhome)## show dualhome Dual Homing Status : DISABLED Magnum 6K25(dualhome)## dualhome add primary=10 secondary=11 Dual Homing Ports configured Magnum 6K25(dualhome)## show dualhome Dual Homing Status : DISABLED Dual Homing Ports : Primary: 10, Secondary: 11 Magnum 6K25(dualhome)## dualhome enable Dual Homing Enabled. Magnum 6K25(dualhome)## show dualhome Dual Homing Status : ENABLED Dual Homing Ports : Primary: 10, Secondary: 11 Dual Homing Active On Port : 10 Magnum 6K25(dualhome)## exit Magnum 6K25# FIGURE 96 – configuring dual-homing

Page 174 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 174 · click to enlarge
Page 174

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

List of commands in this chapter

Syntax dualhome – enter the dual-homing configuration sub-system Syntax dualhome <enable|disable> – enable or disable dual-homing Syntax dualhome add port1=<port#> port2=<port#> – dual-homing setup similar to that of unmanaged switches such as ESD42 OR Syntax dualhome add primary=<port#> secondary=<port#> – dual-homing setup as primary-secondary mode Syntax dualhome del – Delete the dual-homing setup Syntax show dualhome – Display dual-homing status

Page 175 of the GarrettCom MNS-6K user manual — j
Page 175 · click to enlarge
Page 175

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E Chapter 14

14 – Link Aggregation Control Protocol (LACP)

Increase Network throughput and reliability

ink aggregation Link Aggregation Control Protocol (LACP) is part of an IEEE specification (IEEE 802.3ad) that allows several physical ports to be grouped or bundled together to form a single logical channel. This increases the throughput across two devices and provides improved reliability. L

j

The IEEE802.3ad standard provides for the formation of a single Layer 2 link from two or more standard Ethernet links using the Link Aggregation Control Protocol (LACP). LACP provides a robust means of assuring that both ends of the link are up and agree to be members of the aggregation before the link member is activated. LACP trunking is a method of combining physical network links into a single logical link for increased bandwidth. With LACP the effective bandwidth of a trunk and network availability is increased. Two or more Fast Ethernet connections are combined as one logical trunk in order to increase the bandwidth and to create resilient and redundant links. By taking multiple LAN connections and treating them as a unified, aggregated link, Link Aggregation provides the following important benefits:

  • Higher link availability – in case a link fails, the other links continue to operate
  • Increased link capacity – the effective throughput is increased
  • Better port utilization – allows unused ports to be used as trunk ports allowing better throughput and availability
  • Interoperability – being a standard allows LACP to work across different hardware platforms where LACP is supported Failure of any one physical link will not impact the logical link defined using LACP. The loss of a link within an aggregation reduces the available capacity, but the connection is maintained and the data flow is not interrupted.

LACP concepts

Page 176 of the GarrettCom MNS-6K user manual — LACP Configuration
Page 176 · click to enlarge
Page 176

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

The performance is improved because the capacity of an aggregated link is higher than each individual link alone. 10Mbps or 10/100Mbps or 100Mbps ports can be grouped together to form one logical link. Instead of adding new hardware to increase speed on a trunk – one can now use LACP to incrementally increase the throughput in the network, preventing or deferring hardware upgrades. Some known issues with LACP on the Magnum 6K family of switches are:

  • LACP will not work on Half Duplex ports.
  • All trunk ports must be on the same module. Trunk ports cannot be spread out across different modules.
  • All trunk ports MUST have the same speed setting. If the speed is different, LACP shows an error indicating speed mismatch.
  • Many switches do not forward the LACPDUs by default. So, it is possible to hook up multiple ports to these switches and create an Ethernet loop. (In many cases this is prevented by Spanning Tree running on these switches).
  • All ports in a trunk group should be members of the same VLAN. Each port can be a member of multiple VLANs, but each port should have at least one VLAN that is common to both the port groups.
  • The LACPDU packets are sent out every 30 seconds. It is possible that in configuring LACP, a loop can be created until LACP notification is completed. It is recommended to configure LACP first and then physically connect the ports to avoid this potential issue.
  • Port Security will not work with the ports configured for LACP.
  • IGMP will work with the primary LACP port only. All IGMP traffic is sent via a primary port. If needed, this port can be mirrored for traffic analysis.

LACP Configuration

For LACP to work on the Magnum 6K family of switches, only one trunk per module can be created. Some valid connections are shown in the picture below.

Page 177 of the GarrettCom MNS-6K user manual — Switch 1
Page 177 · click to enlarge
Page 177

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

GarrettCom MNS-6K — LACP concepts diagram (page 177)
Fig. 12 · LACP concepts

FIGURE 97 – Some valid LACP configurations.

Should trunks be created so as to span multiple ports, a “trunk mismatch” error message is printed on the console. An example of an incorrect configuration is shown below.

Switch 1

Switch 2

FIGURE 98 – an incorrect LACP connection scheme for Magnum 6K family of switches. All LACP trunk ports must be on the same module and cannot span different modules.

Another example is highlighted below where some ports belong to VLAN 10 (shown in red) and other ports belong to VLAN 20 (shown in blue). If the port groups do not have a common VLAN between them, LACP does not form a connection.

Show 4 more labels / short text on this page
Switch 1 · Switch 1 · Switch 2 · Switch 2
Page 178 of the GarrettCom MNS-6K user manual — Switch 1
Page 178 · click to enlarge
Page 178

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Switch 1

VLAN 20 VLAN 10

Switch 2

FIGURE 99 – In this figure, even though the connections are from one module to another, this is still not a valid configuration (for LACP using 4 ports) as the trunk group belongs to two different VLANs.

However – on each switch, the set of ports can belong to same VLANs as shown in the figure below. While the ports belong to the same VLANs, there is no common VLAN between the switches and hence the LACPDU cannot be transmitted. This configuration will not work in the LACP mode.

Switch 1

VLAN 10

VLAN 20

Switch 2

FIGURE 100 - In the figure above, there is no common VLAN between the two sets of ports, so packets from one VLAN to another cannot be forwarded. There should be at least one VLAN common between the two switches and the LACP port groups.

Page 179 of the GarrettCom MNS-6K user manual — Switch 1
Page 179 · click to enlarge
Page 179

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Switch 1

VLAN 1,10 VLAN 1,20

Switch 2

FIGURE 101 – This configuration is similar to the previous configuration, except there is a common VLAN (VLAN 1) between the two sets of LACP ports. This is a valid configuration.

Switch 1

Switch 2

Switch 3

FIGURE 102 – In the architecture above, using RSTP and LACP allows multiple switches to be configured together in a meshed redundant link architecture. First define the RSTP configuration on the switches. Then define the LACP ports. Then finally connect the ports together to form the meshed redundant link topology as shown above.

Page 180 of the GarrettCom MNS-6K user manual — Switch 2
Page 180 · click to enlarge
Page 180

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Using the Magnum edge switch with dual-homing allows the edge devices to have link level redundancy as well – bringing the fault tolerance from the network to the edge.

Switch 1

GarrettCom MNS-6K — Switch 1 diagram (page 180)
Fig. 13 · Switch 1

Switch 2

H a r d e n e d Ma gnum E 42 S

E d g e S w i t c h

FIGURE 103 – LACP, along with RSTP/STP brings redundancy to the network core or backbone. Using this reliable core with a dual-homed edge switch brings reliability and redundancy to the edge of the network

It is recommended not to use LACP with S-Ring at this time. Since S-Ring and LACP use the same BPDUs (called LACPDUs), the architecture shown below is not supported in this release.

Dual-Homed Edge Switch

Page 181 of the GarrettCom MNS-6K user manual — S-Ring 1
Page 181 · click to enlarge
Page 181

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

S-Ring 1

S-Ring 2

FIGURE 104 – This architecture is not recommended

LACP can be used for creating a reliable network between two facilities connected via a wireless bridge. As shown in the figure below, four trunk ports are connected to four wireless bridge pairs. This increases the effective throughput of the wireless connections and also increases the reliability. If one of the bridges were to stop functioning, the other three will continue to operate, providing a very reliable infrastructure.

Page 182 of the GarrettCom MNS-6K user manual — Facility 1
Page 182 · click to enlarge
Page 182

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Facility 1

A

A

A A

A A

A

A

Facility 2

FIGURE 105 – Creating a reliable infrastructure using wireless bridges (between two facilities) and LACP. “A” indicates a Wi-Fi wireless Bridge or other wireless Bridges.

The list of commands to configure, edit and manage LACP on the Magnum 6K family of switches is the following: Syntax lacp - enable the LACP configuration module within CLI Syntax lacp <enable | disable> - enable or disable LACP7 Syntax add port=<number|list|range> [priority=<0-65535>] – add the specified list of ports

to form the logical LACP trunk. Default value for priority is 32768. The lower the value assigned to priority, the higher the priority. The port with the highest priority is the primary port. Syntax del port=<number|list|range> - delete specified ports from the LACP membership Syntax edit port=<number|list|range> [priority=<priority>] - edit the membership of the

ports specified. The priority can be from 0 – 65535 Syntax show lacp – displays the status and other relevant LACP information

7 Before enabling, please ensure that the correct ports are configured. If network connectivity is lost due to a port being configured as a LACP port, you will need to physically access the switch via the console to correct this error.

Page 183 of the GarrettCom MNS-6K user manual — LACP concepts
Page 183 · click to enlarge
Page 183

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Some other definitions are worth noting are primary port. Primary port is the port over which specific traffic like Multicast (IGMP), unknown Unicast and broadcast traffic is transmitted. As shown by the add port command, the port with the lowest priority value has the highest priority and is designated as the primary port. If traffic analysis is required, it is recommended to mirror the primary port (and physically disconnect the other ports if all traffic needs to be captured). If multiple ports have the same priority, the first port physically connected becomes the primary port. In case the ports are already connected, the port with the lowest port count becomes the primary port i.e. if ports 4, 5, 6 are designated as the LACP group, port 4 would become the primary port. If the primary port fails, the next available secondary port is designated as the primary port. So in the example above, if port 4 fails, port 5 will be designated as the primary port.

Magnum 6K25# show lacp LACP is Disabled. Magnum 6K25# lacp Magnum 6K25(lacp)## add port=14,15,16 Error : LACP is disabled. Magnum 6K25(lacp)## lacp enable LACP Enabled. Magnum 6K25(lacp)## add port=13-16 Port(s) added successfully. Magnum 6K25(lacp)## show lacp Orphan Ports: Port Priority Trunk ===================== 13 32768 Link Down 14 32768 Link Down 15 32768 Link Down 16 32768 Peer Not a Trunk Magnum 6K25(lacp)## del port=16 Port(s) deleted successfully. Magnum 6K25(lacp)## show lacp Orphan Ports:

Need to enable LACP before ports can be added to the trunk group

Indicates no LACP BPDU can be received from this port. This port was in use and was an error to add this. The next few steps delete this port and add the proper port. See other messages below.

Page 184 of the GarrettCom MNS-6K user manual — LACP concepts
Page 184 · click to enlarge
Page 184

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Port Priority Trunk ===================== 13 32768 Link Down 14 32768 Link Down 15 32768 Link Down Magnum 6K25(lacp)## add port=12 Port(s) added successfully. Magnum 6K25(lacp)## show lacp Orphan Ports: Port Priority Trunk ===================== 12 32768 Link Down 13 32768 Link Down 14 32768 Link Down 15 32768 Link Down Magnum 6K25(lacp)## exit Magnum 6K25# show lacp Orphan Ports: Port Priority Trunk ===================== 12 32768 Link Down 13 32768 Link Down 14 32768 Link Down 15 32768 Link Down Magnum 6K25# FIGURE 106 – Configuring LACP

The error messages received when a trunk port is not configured properly are as follows: Link Down Link is down or the cable is not connected Half duplex A Half Duplex port – Half Duplex ports cannot participate in LACP Loop Detected Indicates the other side does not have LACP configured. Without LACP configured on both switches, the network will create an Ethernet loop. Peer Not a Trunk When no LACPDU was received (or cannot be received) from the

peer. This maybe due to the fact that the port is already in use or is shutdown or not available Speed Mismatch All ports in a trunk should have the same speed. If one port’s speed does not match the other ports, this specific port cannot join the port group.

Page 185 of the GarrettCom MNS-6K user manual — Switch 1
Page 185 · click to enlarge
Page 185

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Trunk Mismatch The other switch sent a BPDU which did not match the trunk information associated with this port. This happens when the port is connected to a different switch, or a different module in the Magnum 6K switch The output of the LACP command in the network shown below

Switch 1

Switch 2

Switch 3

FIGURE 107 – The network for the ‘show lacp’ command listed below

In the figure shown above, Switch 1 has ports 11 and 15 forming the first trunk, connecting to Switch 3. Switch 1 also has ports 17 and 23 forming the second trunk on Switch 2. The ‘show lacp’ command was executed on Switch 1.

Magnum 6K(lacp)## show lacp Trunk Id : 1 Trunk Status : Trunk Active Primary Port : 11 Trunk Partner : 00:20:06:25:11:40 Member Ports: Port Priority Trunk ===================== 11 32768 Primary Port 15 32768 Member Port Trunk Id : 2 Trunk Status : Trunk Active Primary Port : 17

Unique ID of trunk

MAC address of Switch 3

Ports belonging to this trunk

Page 186 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 186 · click to enlarge
Page 186

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Trunk Partner : 00:20:06:25:72:90 Member Ports: Port Priority Trunk ===================== 17 32768 Primary Port 23 32768 Member Port FIGURE 108 – LACP information over a network

List of commands in this chapter

Syntax lacp - enable the LACP configuration module within CLI Syntax lacp <enable | disable> - enable or disable LACP Syntax add port=<number|list|range> [priority=<0-65535>] – add the specified list of ports

to form the logical LACP trunk. Default value for priority is 32768. The lower the value assigned to priority, the higher the priority. The port with the highest priority is the primary port (over which certain types of traffic like IGMP is transmitted) Syntax del port=<number|list|range> - delete specified ports from the LACP membership Syntax edit port=<number|list|range> [priority=<priority>] - edit the membership of the

ports specified. The priority can be from 0 – 65535 Syntax show lacp – displays the status and other relevant LACP information

Page 187 of the GarrettCom MNS-6K user manual — j
Page 187 · click to enlarge
Page 187

Chapter 15

15 – Quality of Service

Prioritize traffic in a network

uality of Service (QoS) refers to the capability of a network to provide different priorities to different types of traffic. Not all traffic in the network has the same priority. Being able to differentiate different types of traffic and allowing this traffic to accelerate through the network improves the overall performance of the network and provides the necessary quality of service demanded by different users and devices. The primary goal of QoS is to provide priority including dedicated bandwidth. Q

j

The Magnum 6K family of switches supports QoS as specified in the IEEE 802.1p and IEEE 802.1q standards. QoS is important in network environments where there are time-critical applications, such as voice transmission or video conferencing, which can be adversely effected by packet transfer delays or other latency in a network.

Most switches today implement buffers to queue incoming packets as well as outgoing packets. In a queue mechanism, normally the packet which comes in first leaves first (FIFO) and all the packets are serviced accordingly. Imagine, if each packet had a priority assigned to it. If a packet with a higher priority than other packets were to arrive in a queue, the packet would be given a precedence and moved to the head of the queue and would go out as soon as possible. The packet is thus preempted from the queue and this method is called preemptive queuing. Preemptive queuing makes sense if there are several levels of priorities, normally more than two. If there are too many levels, then the system has to spend a lot of time managing the preemptive nature of queuing. IEEE 802.1p defines and uses eight levels of priorities. The eight levels of priority are enumerated 0 to 7, with 0 the lowest priority and 7 the highest. To make the preemptive queuing possible, most switches implement at least two queue buffers. The Magnum 6K family of switches has two priority queues, 1 (low) and 0 (high).When tagged packets enter a switch port, the switch responds by placing

QoS concepts

Page 188 of the GarrettCom MNS-6K user manual — DiffServ and QoS
Page 188 · click to enlarge
Page 188

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

the packet into one of the two queues, and depending on the precedence levels the queue could be rearranged to meet the QoS requirements. QoS refers to the level of preferential treatment a packet receives when it is being sent through a network. QoS allows time sensitive packets such as voice and video, to be given priority over time insensitive packets such as data. Differentiated Services (DiffServ or DS) are a set of technologies defined by the IETF (Internet Engineering Task Force) to provide quality of service for traffic on IP networks.

DiffServ and QoS

DiffServ is designed for use at the edge of an Enterprise where corporate traffic enters the service provider environment. DiffServ is a layer-3 protocol and requires no specific layer-2 capability, allowing it to be used in the LAN, MAN, and WAN. DiffServ works by tagging each packet (at the originating device or an intermediate switch) for the requested level of service it requires across the network.

Type ToS Data FCS

Type ToS Data FCS

Diffserv Code Points (DSCP) Unused

Diffserv Code Points (DSCP) Unused

FIGURE 109 – ToS and DSCP

DiffServ inserts a 6-bit DiffServ code point (DSCP) in the Type of Service (ToS) field of the IP header, as shown in the picture above. Information in the DSCP allows nodes to determine the Per Hop Behavior (PHB), which is an observable forwarding behavior for each packet. PHBs are defined according to:

  • Resources required (e.g., bandwidth, buffer size)
  • Priority (based on application or business requirements)
  • Traffic characteristics (e.g., delay, jitter, packet loss) Nodes implement PHBs through buffer management and packet scheduling mechanisms. This hop-by-hop allocation of resources is the basis by which DiffServ provides quality of service for different types of communications traffic.
Show 4 more labels / short text on this page
IP Header · IP Header · DMAC SMAC Protocol · DMAC SMAC Protocol
Page 189 of the GarrettCom MNS-6K user manual — ToS byte
Page 189 · click to enlarge
Page 189

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

IP Precedence

IP Precedence utilizes the three precedence bits in the IPv4 header's Type of Service (ToS) field to specify class of service for each packet. You can partition traffic in up to eight classes of service using IP precedence. The queuing technologies throughout the network can then use this signal to provide the appropriate expedited handling.

Data +FCS

Data +FCS

GarrettCom MNS-6K — Data +FCS diagram (page 189)
Fig. 14 · Data +FCS
GarrettCom MNS-6K — Data +FCS diagram (page 189)
Fig. 15 · Data +FCS

ToS byte

ToS byte

3 bits

3 bits

IP precedence

IP precedence

FIGURE 110 - IP Precedence ToS Field in an IP Packet Header

The 3 most significant bits (correlating to binary settings 32, 64, and 128) of the Type of Service (ToS) field in the IP header constitute the bits used for IP precedence. These bits are used to provide a priority from 0 to 7 for the IP packet. Because only 3 bits of the ToS byte are used for IP precedence, you need to differentiate these bits from the rest of the ToS byte. The Magnum 6K family of switches has the capability to provide QoS at Layer 2. At Layer 2, the frame uses Type of Service (ToS) as specified in IEEE 802.1p . ToS uses 3 bits, just like IP precedence, and maps well from Layer 2 to layer 3, and vice versa. The switches have the capability to differentiate frames based on ToS settings. With two queues present - high or low priority queues or buffers in Magnum 6K family of switches, frames can be placed in either queue and serviced via the weight set on all ports. This placement of queues, added to the weight set plus the particular tag setting on a packet allows each queue to have different service levels. Magnum QoS implementations provide mapping of ToS (or IP precedence) to Class of Service (CoS). A CoS setting in an Ethernet Frame is mapped to the ToS byte of the IP packet, and vice versa. A ToS level of 1 equals a CoS level of 1. This provides end-to-end priority for the traffic flow when Magnum 6K family of switches are deployed in the network.

Page 190 of the GarrettCom MNS-6K user manual — Configuring QoS
Page 190 · click to enlarge
Page 190

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Not all packets received on a port have high priority. IGMP and BPDU packets have high priority by default. The Magnum 6K family of switches has the capability to set the priorities based on three different functions. They are Port QoS: assigns a high priority to all packets received on a port, regardless of the type of packet. TAG QoS: if a packet contains a tag, the port on which the packet was received then looks to see at which level that tag value is set. Regardless of the tag value, if there is a tag, that packet is automatically assigned high priority (sent to the high priority queue) ToS QoS: (Layer 3) when a port is set to ToS QoS, the most significant 6-bits of the IPv4 packet (which has 64 bits) are used. If the 6 bits are set to ToS QoS for the specific port number the packet went to, that packet is assigned high priority by that port

Configuring QoS

Magnum 6K family of switches support three types of QoS - Port based, Tag based and ToS based.

QoS is disabled by default on the switch. QoS needs to be enabled and configured. Syntax qos – enter the QoS configuration mode Syntax set qos type=<port|tag|tos|none> port=<port|list|range>

[priority=<high|low>] [tos=<0-63|list|range>][tag=<0-7|list|range>] - depending on the type of QOS, the corresponding field has to be set. For example, for QOS type tag, the tag levels have to be set, and for QOS type ToS, the ToS levels have to be set. If the priority field is not set, it then defaults to low priority. ToS has 64 levels and the valid values are 0-63 and a tagged packet has 8 levels and the valid values are 0-7.

Setting type to none will clear the QoS settings

Page 191 of the GarrettCom MNS-6K user manual — QoS concepts
Page 191 · click to enlarge
Page 191

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax set-weight weight=<0-7> - sets the port priority weight for All the ports. Once the weight is

set, all the ports will be the same weight across the switch. The valid value for weight is 0-7.

A weight is a number calculated from the IP precedence setting for a packet. This weight is used in an algorithm to determine when the packet will be serviced Syntax show-portweight - display the weight settings on a port As mentioned previously, the switch is capable of detecting higher-priority packets marked with precedence by the IP forwarder and can schedule them faster, providing superior response time for this traffic. The IP Precedence field has values between 0 (the default) and 7. As the precedence value increases, the algorithm allocates more bandwidth to that traffic to make sure that it is served more quickly when congestion occurs. Magnum 6K family of switches can assign a weight to each flow, which determines the transmit order for queued packets. In this scheme, lower weights (set on all ports) are provided more service. IP precedence serves as a divisor to this weighting factor. For instance, traffic with an IP precedence field value of 7 gets a lower weight than traffic with an IP Precedence field value of 3, and thus has priority in the transmit order. Once the port weight is set, the hardware will interpret the weight setting for all ports as outlined below (assuming the queues are sufficiently filled – if there are no packets, for example, in the high priority queue, packets are serviced on a first come first served - FCFS - basis from the low priority queue).

Setting Hardware traffic queue behavior 0 No priority – traffic is sent alternately from each queue and packets are queued alternately in each queue 1 Two packets are sent from the HIGH priority queue and one packet from LOW priority queue 2 Four packets are sent from the HIGH priority queue and one packet from LOW priority queue 3 Six packets are sent from the HIGH priority queue and one packet from LOW priority queue 4 Eight packets are sent from the HIGH priority queue and one packet from LOW priority queue 5 Ten packets are sent from the HIGH priority queue and one packet from LOW priority queue 6 Twelve packets are sent from the HIGH priority queue and one packet from LOW priority queue 7 All packets are sent from the HIGH priority queue and none are sent from LOW priority queue FIGURE 111 - Port weight settings and the meaning of the setting

Page 192 of the GarrettCom MNS-6K user manual — QoS concepts
Page 192 · click to enlarge
Page 192

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax show qos [type=<port|tag|tos>] [port=<port|list|range>] – displays the QoS settings Sometimes it is necessary to change the priority of the packets going out of a switch. For example, when a packet is received untagged and has to be transmitted with an addition of the 802.1p priority tag, the tag can be assigned depending on the untag value set. For example if the untag command is set to port=1 tag=2 priority=low, untagged packets received on that port will be tagged with a priority low upon transmit. Syntax set-untag port=<port|list|range> priority=<high|low> tag=<0-7> - The 802.1p user priority assigned to untagged received packets to be transmitted as tagged from the priority queue

Magnum6K25# show port Keys: E = Enable D = Disable H = Half Duplex F = Full Duplex M = Multiple VLAN's NA = Not Applicable LI = Listening LE = Learning F = Forwarding B = Blocking Port Name Control Dplx Media Link Speed Part Auto VlanID GVRP STP 9 B1 E H 10Tx UP 10 No E 1 - - 10 B2 E H 10Tx DOWN 10 No E 1 - - 11 B3 E H 10Tx DOWN 10 No E 1 - - 12 B4 E H 10Tx DOWN 10 No E 1 - - 13 B5 E F 100Tx UP 100 No E 1 - - 14 B6 E H 10Tx DOWN 10 No E M - - 15 B7 E H 10Tx DOWN 10 No E 1 - - 16 B8 E H 10Tx DOWN 10 No E 1 - - Magnum6K25#qos Magnum6K25(qos)## setqos type=port port=10 priority=high Successfully set QOS. Magnum6K25(qos)## show qos ============================== PORT | QOS | STATUS ============================== 9 | None | UP 10 | Port | DOWN 11 | None | DOWN 12 | None | DOWN 13 | None | UP 14 | None | DOWN 15 | None | DOWN 16 | None | DOWN Magnum6K25(qos)## show qos type=port

All traffic on port 10 is sent to the high priority queue

Page 193 of the GarrettCom MNS-6K user manual — QoS concepts
Page 193 · click to enlarge
Page 193

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

================================ PORT | PRIORITY | STATUS ================================ 9 | Low | UP 10 | High | DOWN 11 | Low | DOWN 12 | Low | DOWN 13 | Low | UP 14 | Low | DOWN 15 | Low | DOWN 16 | Low | DOWN Magnum6K25(qos)## setqos port=11 priority=high type=tag tag=6 Successfully set QOS. Magnum6K25(qos)## show qos ============================== PORT | QOS | STATUS ============================== 9 | None | UP 10 | Port | DOWN 11 | Tag | DOWN 12 | None | DOWN 13 | None | UP 14 | None | DOWN 15 | None | DOWN 16 | None | DOWN Magnum6K25(qos)## show qos type=tag ============================== PORT | QOS | STATUS ============================== 9 | | UP 10 | | DOWN 11 | 6 | DOWN 12 | | DOWN 13 | | UP 14 | | DOWN 15 | | DOWN 16 | | DOWN Magnum6K25(qos)## setqos port=12 priority=high type=tag tag=5 Successfully set QOS. Magnum6K25(qos)## show qos type=tag ============================== PORT | QOS | STATUS ==============================

All traffic on port 11 is sent to the high priority queue and the QoS tag is set to 6

Page 194 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 194 · click to enlarge
Page 194

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

9 | | UP 10 | | DOWN 11 | 6 | DOWN 12 | 5 | DOWN 13 | | UP 14 | | DOWN 15 | | DOWN 16 | | DOWN Magnum6K25(qos)## show-portweight Port priority Weight set to 1 High : 1 Low. Magnum6K25(qos)## set-weight weight=4

The queue behavior is set so that for 8 high priority packets, 1 low priority packet is sent out

Magnum6K25(qos)## show-portweight Port priority Weight set to 8 High : 1 Low. Magnum6K25(qos)## show qos ============================== PORT | QOS | STATUS ============================== 9 | None | UP 10 | Port | DOWN 11 | Tag | DOWN 12 | Tag | DOWN 13 | None | UP 14 | None | DOWN 15 | None | DOWN 16 | None | DOWN FIGURE 112 – QoS configuration and setup

List of commands in this chapter

Syntax qos – enter the QoS configuration mode Syntax setqos type=<port|tag|tos|none> port=<port|list|range>

[priority=<high|low>] [tos=<0-63|list|range>][tag=<0-7|list|range>] - depending on the type of QOS, the corresponding field has to be set. For example, for QOS type tag, the tag levels have to be set, and for QOS type ToS, the ToS levels have to be set. If the priority field is not set, it then defaults to low priority. ToS has 64 levels and the valid values are 0-63 and a tagged packet has 8 levels and the valid values are 0-7. Syntax set-weight weight=<0-7> - sets the port priority weight for All the ports. Once the weight is

set, all the ports will be the same weight across the switch. The valid value for weight is 0-7 Syntax show-portweight - display the weight settings on a port

Page 195 of the GarrettCom MNS-6K user manual — QoS concepts
Page 195 · click to enlarge
Page 195

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax show qos [type=<port|tag|tos>] [port=<port|list|range>] – displays the QoS

settings Syntax set-untag port=<port|list|range> priority=<high|low> tag=<0-7> - The

802.1p user priority assigned to untagged received packets to be transmitted as tagged from the priority queue

Page 196 of the GarrettCom MNS-6K user manual — j
Page 196 · click to enlarge
Page 196

Chapter 16

16 – IGMP

Multicast traffic on a network

nternet Group Management Protocol (IGMP) is defined in RFC 1112 as the standard for IP multicasting in the Internet. It is used to establish host memberships in particular multicast groups on a single network. The mechanisms of the protocol allows a host to inform its local router, using Host Membership Reports that it wants to receive messages addressed to a specific multicast group. All hosts conforming to level 2 of the IP multicasting specification require IGMP.

MP concepts8 he Magnum 6K family of switches supports IGMP L2 standards as efined by RFC 1112. IGMP is disabled by default and needs to be enabled on the Magnum 6K family of switches. IP multicasting is defined as the transmission of an IP datagram to a "host group", a set of zero or more hosts identified by a single IP destination address. A multicast datagram is delivered to all members of its destination host group with the same "best-efforts" reliability as regular unicast IP datagram, i.e. the datagram is not guaranteed to arrive at all members of the destination group or in the same order relative to other datagram.

j

The membership of a host group is dynamic; that is, hosts may join and leave groups at any time. There is no restriction on the location or number of members in a host group, but membership in a group may be restricted to only those hosts possessing a private access key. A host may be a member of more than one group at a time. A host need not be a member of a group to send datagram to it.

A host group may be permanent or transient. A permanent group has a well-known, administratively assigned IP address. It is the address and not the membership of the group that is permanent; at any time a permanent group may have any number of members, even zero. A transient group on the other hand is assigned an address dynamically when the group is created, at the request of a host. A transient group ceases to exist, and its address becomes eligible for reassignment, when its membership drops to zero.

8 Most of the concepts are extracted from RFC 1112 and it is recommended that RFC 1112 be read and understood carefully if IGMP is used or planned for the network.

IG T d

Page 197 of the GarrettCom MNS-6K user manual — IGMP concepts
Page 197 · click to enlarge
Page 197

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

The creation of transient groups and the maintenance of group membership information is the responsibility of "multicast agents", entities that reside in internet gateways or other special- purpose hosts. There is at least one multicast agent directly attached to every IP network or sub- network that supports IP multicasting. A host requests the creation of new groups, and joins or leaves existing groups, by exchanging messages with a neighboring agent.

  • The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet Protocol (IP) suite. IP manages multicast traffic by using switches, multicast routers, and hosts that support IGMP. A set of hosts, routers, and/or switches that send or receive multicast data streams to or from the same source(s) is termed a multicast group , and all devices in the group use the same multicast group address. The multicast group running version 2 of IGMP uses three fundamental types of messages to communicate:
  • Query: A message sent from the querier (multicast router or switch) asking for a response from each host belonging to the multicast group. If a multicast router supporting IGMP is not present, then the switch must assume this function in order to elicit group membership information from the hosts on the network. (If you need to disable the querier feature, you can do so through the CLI, using the IGMP configuration MIB. See “Changing the Querier Configuration Setting” on page “Configuring the Querier Function”)
  • Report: A message sent by a host to the querier to indicate that the host wants to be or is a member of a given group indicated in the report message.
  • Leave Group: A message sent by a host to the querier to indicate that the host has ceased to be a member of a specific multicast group. Thus, IGMP identifies members of a multicast group (within a subnet) and allows IGMP-configured hosts (and routers) to join or leave multicast groups. When IGMP is enabled on the Magnum 6K family of switches, it examines the IGMP packets it receives:
  • To learn which of its ports are linked to IGMP hosts and multicast routers/queriers belonging to any multicast group.
  • To become a querier if a multicast router/querier is not discovered on the network. Once the switch learns the port location of the hosts belonging to any particular multicast group, it can direct group traffic to only those ports, resulting in bandwidth savings on ports where group members do not reside. The following example illustrates this operation. The figure below shows a network running IGMP.
Page 198 of the GarrettCom MNS-6K user manual — IGMP concepts
Page 198 · click to enlarge
Page 198

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

GarrettCom MNS-6K — IGMP concepts diagram (page 198)
Fig. 16 · IGMP concepts

FIGURE 113 – IGMP concepts – advantages of using IGMP

  • PCs 1 and 4, switch 2, and all of the routers are members of an IP multicast group. (The routers operate as queriers.)
  • Switch 1 ignores IGMP traffic and does not distinguish between IP multicast group members and non-members. Thus, it is sending large amounts of unwanted multicast traffic out the ports to PCs 2 and 3.
  • Switch 2 is recognizing IGMP traffic and learns that PC 4 is in the IP multicast group receiving multicast data from the video server (PC X). Switch 2 then sends the multicast data only to the port for PC 4, thus avoiding unwanted multicast traffic on the ports for PCs 5 and 6.
Page 199 of the GarrettCom MNS-6K user manual — IGMP concepts
Page 199 · click to enlarge
Page 199

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

The next figure (below) shows a network running IP multicasting using IGMP without a multicast router. In this case, the IGMP-configured switch runs as a querier. PCs 2, 5, and 6 are members of the same IP multicast group. IGMP is configured on switches 3 and 4. Either of these switches can operate as querier because a multicast router is not present on the network. (If an IGMP switch does not detect a querier, it automatically assumes this role, assuming the querier feature is enabled—the default—within IGMP.)

GarrettCom MNS-6K — IGMP concepts diagram (page 199)
Fig. 17 · IGMP concepts

FIGURE 114 – IGMP concepts – Isolating multicast traffic in a network

  • In the above figure, the multicast group traffic does not go to switch 1 and beyond. This is because either the port on switch 3 that connects to switch 1 has been configured as blocked or there are no hosts connected to switch 1 or switch 2 that belong to the multicast group.
  • For PC 1 to become a member of the same multicast group without flooding IP multicast traffic on all ports of switches 1 and 2, IGMP must be configured on both switches 1 and 2, and the port on switch 3 that connects to switch 1 must be unblocked. IP Multicast Filters - IP multicast addresses occur in the range from 224.0.0.0 through 239.255.255.255 which corresponds to the Ethernet multicast address range of 01005e-000000 through 01005e-7fffff in hexadecimal. Reserved Addresses Excluded from IP Multicast (IGMP) Filtering – Traffic to IP multicast
Page 200 of the GarrettCom MNS-6K user manual — IGMP-L2
Page 200 · click to enlarge
Page 200

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

groups in the IP address range of 224.0.0.0 to 224.0.0.255 will always be flooded because addresses in this range are “well known” or “reserved” addresses. Thus, if IP Multicast is enabled and there is an IP multicast group within the reserved address range, traffic to that group will be flooded instead of filtered by the switch. IGMP Support - Magnum 6K family of switches support IGMP version 1 and version 2. The switch can act either as a querier or a nonquerier. The querier router periodically sends general query messages to solicit group membership information. Hosts on the network that are members of a multicast group send report messages. When a host leaves a group, it sends a leave group message. The difference between Version 1 and Version 2 is that version 1 does not have a “Leave” mechanism for the host. Magnum 6K family of switches do pruning when there is a leave message or a time expires on a port, we prune the multicast group membership on that port.

1. The Magnum 6K family of switches can snoop up to 256 Multicast groups. It can be enabled within a port VLAN, tagged VLAN, or no VLAN. 2. IGMP is disabled as a default. A switch, with IGMP snooping has the behavior similar to a regular switch (default IGMP behavior) i.e. it forwards the multicast stream (packets) to all the ports.

Now, if a device on any of the ports sends a join report or invokes the IGMP Pruning action, the behavior changes. A multicast group is formed in the switch, and the stream is sent only to those ports that actually want to join the stream.

The default behavior of multicasting streams to all ports could create problems when there are a number of multicast streams that enter the switch though a number of different ports. Each stream goes to ALL OTHER ports and creates congestion in the switch.

The mcast command (described below) controls this default behavior. The default setting is "enable". If it is set to "disable", the default behavior is modified so that the stream is not transmitted or multicast to any of the ports until a device joins the stream from that port.

IGMP-L2

IGMP requires a Layer 3 device in the network. What happens if your network has only Layer 2 devices? Can the Layer 2 devices take advantage of the IGMP technology and reduce the overall traffic in the network, without requiring the presence of a Layer 3 device in the network? Using GarrettCom IGMP-L2 (patent pending technology), it is possible to do that.

The benefits of IGMP are clear. The traditional ways of building an IGMP network calls for the IGMP querier to reside on a Layer 3 network device - typically a router or a Layer 3 switch. The end devices (encoders or transmitters) reside on a Layer 2 device and the encoder sends a query/join request to join the specific multicast group. The Magnum 6K family of switches, with the IGMP-L2 enabled, can propagate the query request and also make sure that the multicast traffic only goes to the ports requesting the traffic. The Magnum 6K family of switches, using IGMP-L2, can perform the similar tasks a Layer 3 device performs for IGMP.

Page 201 of the GarrettCom MNS-6K user manual — IGMP concepts
Page 201 · click to enlarge
Page 201

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

For a Layer 2 IGMP environment, all Magnum 6K family of switches have to be enabled in the IGMP-L2. This is done using the CLI command 'set igmp mode=l2' which will be described later.

In a Layer 2 network, without IGMP-L2, there is no querier nor is there any capability for the devices to use IGMP snooping to join a multicast group. Thus - the traffic picture from a multicast device would look as shown below.

GarrettCom MNS-6K — IGMP concepts diagram (page 201)
Fig. 18 · IGMP concepts

FIGURE 115 - In a Layer 2 network, an IGMP multicast traffic goes to all the nodes. In the figure, T1, a surveillance camera, using multicast, will send the traffic to all the nodes - R1 through R6 - irrespective of whether they want to view the surveillance traffic or not. The traffic is compounded when additional cameras are added to the network. End result is that users R1 through R6 see the network as heavily loaded and simple day to day operations may appear sluggish.

With IGMP-L2 enabled on all Magnum 6K family of switches, this situation as shown above is prevented. This is explained in the figure below.

Page 202 of the GarrettCom MNS-6K user manual — IGMP concepts
Page 202 · click to enlarge
Page 202

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

GarrettCom MNS-6K — IGMP concepts diagram (page 202)
Fig. 19 · IGMP concepts

FIGURE 116 - Using IGMP-L2 on Magnum 6K family of switches, a Layer 2 network can minimize multicast traffic as shown above. Each switch has the IGMPL2 turned on. Each switch can exchange the IGMP query message and respond properly. R4 wants to view surveillance traffic from T1. As shown by (1), a join request is sent by R4. Once the join report information is exchanged, only R4 receives the video surveillance traffic, as shown by (2). No other device on the network gets the video surveillance traffic unless they issue a join request as well.

Since the query and the join information is exchanged between the neighboring switches, the topology does not matter. The design issue to consider is the timing difference between a topology recovery and IGMP refresh (recovery). GarrettCom Magnum 6K family of switches, connected in a S-Ring or RS-Ring topology recovers very rapidly (sub-second recovery). The IGMP requests for updates are sent out every few seconds (depending on the network and the devices on the network). The recovery of the network from a fault situation is much faster than the age out and join request from IGMP. Thus when the Magnum 6K switch network self heals, it is possible that the video may freeze till the (IGMP) device reissues a join request again.

A few additional facts about IGMP L2

  • GarrettCom Magnum 6K family of switches configured for IGMP-L2 can perform the Join aggregation required by IGMP
Page 203 of the GarrettCom MNS-6K user manual — Configuring IGMP
Page 203 · click to enlarge
Page 203

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

  • Multicast forwarding is done based on MAC addresses – so datagram to IP addresses 224.1.2.3 and 239.129.2.3 can be forwarded on the same port groups. It is not possible to do forwarding based on IP addresses as the Magnum 6K family of switches operate at Layer-2
  • Magnum 6K family of switches, configured for IGMP L2 are aware of IP address range 224.0.0.x as well as MAC address range 01:00:5e:00:00:xx aware as required by RFC 4541
  • The Magnum 6K family of switches, configured for IGMP L2 support forwarding to ports on which multicast routers are attached in addition to the ports where IGMP joins have been received. Thus IGMP L2 and IGMP L3 networks can co-exist
  • The Magnum 6K family of switches, configured for IGMP L2 are aware of topology changes, so new queries can be sent or tables updated to ensure robustness

Configuring IGMP

Syntax igmp – IGMP configuration mode Syntax igmp <enable| disable> - enable or disable IGMP on the switch Syntax show igmp – IGMP operation status Syntax mcast <enable | disable> - enable or disable unknown multicast streams. The default is enabled Syntax set igmp mode= <normal|l2> - set the IGMP mode. Normal is when a L3 device is in the network and is the IGMP root. The IGMP-L2 is used when there is no L3 device in the network

Magnum6K25# igmp Magnum6K25(igmp)## igmp enable IGMP is enabled Magnum6K25(igmp)## show igmp IGMP State : Enabled ImmediateLeave : Disabled Querier : Enabled Querier Interval : 125 Querier Response Interval : 10 Multicasting unknown streams : Enabled Magnum6K25(igmp)## mcast disable

Page 204 of the GarrettCom MNS-6K user manual — IGMP concepts
Page 204 · click to enlarge
Page 204

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

MCAST is disabled Magnum6K25(igmp)## show igmp IGMP State : Enabled ImmediateLeave : Disabled Querier : Enabled Querier Interval : 125 Querier Response Interval : 10 Multicasting unknown streams : Disabled Magnum6K25(igmp)## igmp disable IGMP is disabled Magnum6K25(igmp)## show igmp IGMP State : Disabled ImmediateLeave : Disabled Querier : Disabled Querier Interval : 125 Querier Response Interval : 10 Multicasting unknown streams : Disabled Magnum6K25(igmp)## FIGURE 117 – Enabling IGMP and query the status of IGMP

The output of “show igmp” provide useful information. The following information is provided:

IGMP State shows if IGMP is turned on (Enable) or off (Disable). Immediate Leave provides a mechanism for a particular host that wants to leave a multicast group. It disables the port (where the leave message is received) ability to transmit multicast traffic. Querier shows where the switch is acting a querier or a non-querier. In the example above the switch is the querier. Querier Interval shows the time period in seconds on which the switch sends general host- query messages. Querier Response Interval specifies maximum amount of time in seconds that can elapse between when the querier sends a host-query message and when it receives a response from a host.

Page 205 of the GarrettCom MNS-6K user manual — IGMP concepts
Page 205 · click to enlarge
Page 205

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax show-group – shows the multicast groups

Magnum6K25(igmp)## show-group GroupIp PortNo Timer LeavePending 224.1.0.1 9 155 0 224.0.1.40 9 155 0 Magnum6K25(igmp)## FIGURE 118 – Displaying IGMP groups

The output of the “show-group” command displays Group IP column shows the multicast groups. Port No shows the port where the multicast group is being detected. Timer shows the amount of time left in seconds before the group port will be deleted (or will not be able to route multicast traffic) if the switch does not receive a membership report. Leave Pending column shows the number of leave messages received from this port Every port can be individually set to three different IGMP modes – Auto, Block and Forward.

  • Auto – lets IGMP control whether the port should or should not participate sending multicast traffic
  • Block – manually configures the port to always block multicast traffic
  • Forward – manually configures the port to always forward multicast traffic To set the port characteristics, use the set-port in the IGMP configuration command mode Syntax set-port port=< port|list|range> mode=<auto|forward|block> - set the port

characteristics. Block drops the unregistered multicasts. Forward forwards unregistered multicasts Syntax show-port – display the port characteristics for IGMP Syntax show-router – displays detected IGMP-enabled router ports Syntax set-leave <enable|disable> - enables or disables the switch to immediately process a host

sending a leave message rather that wait for the timer to expire

Syntax set-querier <enable|disable> - enables or disables a switch as IGMP querier

Page 206 of the GarrettCom MNS-6K user manual — IGMP concepts
Page 206 · click to enlarge
Page 206

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax set-qi interval=<value> - The IGMP querier router periodically sends general host-query

messages. These messages are sent to ask for group membership information. This is sent to the all- system multicast group address, 224.0.0.1. The default value is 125 seconds. The valid range can be from 60 to 127 seconds.

Syntax set-qri interval=<value> - The query response interval is the maximum amount of time that

can elapse between when the querier router sends a host-query message and when it receives a response from a host. The Default value is 10 seconds. The Range can be from 2 to 270 seconds. Restrictions apply to the maximum value because of an internal calculation that is dependent on the value of the Query Interval.

Magnum6K25# igmp Magnum6K25(igmp)## set-port port=10-12 mode=forward Port mode is set. Magnum6K25(igmp)## set-port port=14-16 mode=block Port mode is set. Magnum6K25(igmp)## show-port Port | Mode 09 Auto 10 Forwarding 11 Forwarding 12 Forwarding 13 Auto 14 Blocking 15 Blocking 16 Blocking Magnum6K25(igmp)## show-router RouterIp PortNo Timer 10.21.1.250 9 25 Magnum6K25(igmp)## set-leave enable IGMP immediate leave status is enabled Magnum6K25(igmp)## show igmp IGMP State : Enabled ImmediateLeave : Enabled Querier : Enabled

Page 207 of the GarrettCom MNS-6K user manual — IGMP concepts
Page 207 · click to enlarge
Page 207

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Querier Interval : 125 Querier Response Interval : 10 Magnum6K25(igmp)## set-leave disable IGMP immediate leave status is disabled Magnum6K25(igmp)## show igmp IGMP State : Enabled ImmediateLeave : Disabled Querier : Enabled Querier Interval : 125 Querier Response Interval : 10 Magnum6K25(igmp)## set-querier enable IGMP querier status is enabled Magnum6K25(igmp)## show igmp IGMP State : Enabled ImmediateLeave : Disabled Querier : Enabled Querier Interval : 125 Querier Response Interval : 10 Magnum6K25(igmp)## set-querier disable IGMP querier status is disabled Magnum6K25(igmp)## show igmp IGMP State : Enabled ImmediateLeave : Disabled Querier : Disabled Querier Interval : 125 Querier Response Interval : 10 Magnum6K25(igmp)## set-qi interval=127 Query interval successfully set Magnum6K25(igmp)## show igmp IGMP State : Enabled ImmediateLeave : Disabled Querier : Disabled Querier Interval 127 Querier Response Interval : 10 Magnum6K25(igmp)## set-qri interval=11

Page 208 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 208 · click to enlarge
Page 208

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Query response interval successfully set Magnum6K25(igmp)## show igmp IGMP State : Enabled ImmediateLeave : Disabled Querier : Disabled Querier Interval : 125 Querier Response Interval : 11 FIGURE 119 – Configuring IGMP

For setting IGMP L2 mode, make sure the set of commands listed below are executed on all the Magnum switches participating in the L2

Magnum 6K25# igmp Magnum 6K25(igmp)## mode L2 IGMP set to L2 Mode. Magnum 6K25(igmp)## show igmp IGMP State : Disabled ImmediateLeave : Disabled Querier : L2 Mode Querier Interval : 125 Querier Response Interval : 10 Multicasting unknown streams : Disabled Magnum 6K25(igmp)## mode normal IGMP set to Normal Mode. Magnum 6K25(igmp)## exit Magnum 6K25# FIGURE 120 - Setting IGMP-L2

List of commands in this chapter

Syntax igmp – IGMP configuration mode Syntax igmp <enable/disable> - enable or disable IGMP on the switch Syntax show igmp – IGMP operation status Syntax mcast <enable | disable> - enable or disable unknown multicast streams. The default is enabled

Page 209 of the GarrettCom MNS-6K user manual — IGMP concepts
Page 209 · click to enlarge
Page 209

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax set igmp mode=<normal|l2> - set the IGMP mode. Normal is when a L3 device is in the network and is the IGMP root. The IGMP-L2 is used when there is no L3 device in the network Syntax show-group – shows the multicast groups Syntax set-port port=< port|list|range> mode=<auto|forward|block> - set the port

characteristics. Block drops the unregistered multicasts. Forward forwards unregistered multicasts Syntax show-port – display the port characteristics for IGMP Syntax show-router – displays detected IGMP-enabled router ports Syntax set-leave <enable|disable> - enables or disables the switch to immediately process a host sending a

leave message rather that wait for the timer to expire Syntax set-querier <enable|disable> - enables or disables a switch as IGMP querier Syntax set-qi interval=<value> - The IGMP querier router periodically sends general host-query messages.

These messages are sent to ask for group membership information. This is sent to the all-system multicast group address, 224.0.0.1. The default value is 125 seconds. The valid range can be from 60 to 127 seconds. Syntax set-qri interval=<value> - The query response interval is the maximum amount of time that can

elapse between when the querier router sends a host-query message and when it receives a response from a host. The Default value is 10 seconds. The Range can be from 2 to 270 seconds. Restrictions apply to the maximum value because of an internal calculation that is dependent on the value of the Query Interval.

Page 210 of the GarrettCom MNS-6K user manual — G G
Page 210 · click to enlarge
Page 210

Chapter 17

17 – GVRP

Generic Attribute Registration Protocol (GARP) VLAN Registration Protocol (GVRP)

eneric Attribute Registration Protocol (GARP) and VLAN registration over GARP is called GVRP. GVRP is defined in the IEEE 802.1q and GARP in the IEEE 802.1p standards. In order to utilize the capabilities of GVRP, GarrettCom Inc. strongly recommends that the user is familiar with the concepts and capabilities of IEEE 802.1q. G

G G

Without GVRP, a network administrator has to go to each individual switch and enable the necessary VLAN information or block specific VLAN’s so that the network integrity is maintained. With GVRP this process can be automated. j

VRP makes it easy to propagate VLAN information across multiple switches.

It is critical that all switches share a common VLAN. This VLAN typically is the default VLAN (VID=1) on most switches and other devices. GVRP uses “GVRP Bridge Protocol Data Units” (“GVRP BPDUs”) to “advertise” static VLANs. We refer to GVRP BPDU as an “advertisement”. GVRP enables the Magnum 6K family of switches to dynamically create 802.1q-compliant VLANs on links with other devices running GVRP. This enables the switch to automatically create VLAN links between GVRP-aware devices. A GVRP link can include intermediate devices that are not GVRP-aware. This operation reduces the chances for errors in VLAN configuration by automatically providing VLAN ID (VID) consistency across the network. GVRP can thus be used to propagate VLANs to other GVRP-aware devices instead of manually having to set up VLANs across the network. After the switch creates a dynamic VLAN, GVRP can also be used to dynamically enable port membership

in static VLANs configured on a switch.

There must be one common VLAN (that is, one common VID) connecting all of the GVRP-aware devices in the network to carry GVRP packets. GarrettCom Inc. recommends the default VLAN (DEFAULT_VLAN; VID = 1), which is automatically enabled and

VRP concepts

Page 211 of the GarrettCom MNS-6K user manual — GVRP Operations
Page 211 · click to enlarge
Page 211

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

configured as untagged on every port of the Magnum 6K family of switches. That is, on ports used as GVRP links, leave the default VLAN set to untagged and configure other static VLANs on the ports as either “Tagged or Forbid”. (“Forbid” is discussed later in this chapter.)

GVRP Operations

A GVRP-enabled port with a Tagged or Untagged static VLAN sends advertisements (BPDUs, or Bridge Protocol Data Units) advertising the VLAN identification (VID). Another GVRP-aware port receiving the advertisements over a link can dynamically join the advertised VLAN. All dynamic VLANs operate as Tagged VLANs. Also, a GVRP-enabled port can forward an advertisement for a VLAN it learned about from other ports on the same switch. However, the forwarding port will not itself join that VLAN until an advertisement for that VLAN is received on that specific port.

Switch 1 GVRP On

Switch 1 GVRP On

Switch 2 GVRP On

Switch 2 GVRP On

Switch 2 GVRP On

Switch 3 GVRP On

Switch 3 GVRP On

Switch 3 GVRP On

Static VLAN configured end device (NIC or switch) with

Static VLAN configured end device (NIC or switch) with

FIGURE 121 – GVRP operation – see description below

Switch 1 with static VLANs (VID= 1, 2, & 3). Port 2 is a member of VIDs 1, 2, & 3.

1. Port 2 advertises VIDs 1, 2, & 3 2. On Switch 2 - Port 1 receives advertisement of VIDs 1, 2, & 3 AND becomes a member of VIDs 1, 2, & 3 3. As discussed above, a GVRP enabled port can forward advertisement for a VLAN it learnt about. So port 3 advertises VIDs 1, 2, & 3, but port 3 is NOT a member of VIDs 1, 2, & 3 at this point, nor will it join the VLAN until and advertisement is received 4. On Switch 3, port 4 receives advertisement of VIDs 1, 2, & 3 and becomes a member of VIDs 1, 2, & 3 5. Port 5 advertises VIDs 1, 2,& 3, but port 5 is NOT a member of VIDs 1, 2, & 3 at this point 6. Port 6 on the end device is statically configured to be a member of VID 3. Port 6 advertises VID 3 7. Port 5 receives advertisement 8. Port 4 advertises VID 3 9. Port 3 receives advertisement of VID 3 AND becomes a member of VID 3. (Still not a member of VIDs 1 & 2 as it did not receive any advertisements for VID 1 or 2) 10. Port 1 advertises VID 3 AND becomes a member of VID 3. (Port 1 is still not a member of VIDs 1 & 2)

GVRP on 6 · GVRP on 6

Page 212 of the GarrettCom MNS-6K user manual — Dynamic VLAN 22
Page 212 · click to enlarge
Page 212

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

11. Port 2 receives advertisement of VID 3. (Port 2 was already statically configured for VIDs 1, 2, 3)

If a static VLAN is configured on at least one port of a switch, and that port has established a link with another device, then all other ports of that switch will send advertisements for that VLAN. In the figure below, tagged VLAN ports on switch “A” and switch “C” advertise VLANs 22 and 33 to ports on other GVRP-enabled switches that can dynamically join the VLANs. A port can learn of a dynamic VLAN through devices that are not aware of GVRP (Switch “B”.)

Switch C GVRP On

Switch C GVRP On

Switch C Port 5 dynamically joined VLAN 22 Ports 11, 12 belong to Tagged VLAN 33

Switch C Port 5 dynamically joined VLAN 22 Ports 11, 12 belong to Tagged VLAN 33

Switch A GVRP On

Switch A GVRP On

Tagged VLAN 22

Tagged VLAN 22

Tagged VLAN 22

Tagged VLAN 22

Switch E GVRP On Dynamic VLAN 33

Switch E GVRP On Dynamic VLAN 33

Tagged VLAN 33

Tagged VLAN 33

Switch D GVRP On Dynamic VLAN 33

Switch D GVRP On Dynamic VLAN 33

Dynamic VLAN 22

Dynamic VLAN 22

Switch B No GVRP

Switch B No GVRP

Tagged VLAN 22

Tagged VLAN 22

Switch E Port 2 dynamically joined VLAN 33 Ports 7 dynamically joined VLAN 33

Switch E Port 2 dynamically joined VLAN 33 Ports 7 dynamically joined VLAN 33

Dynamic VLAN 22

Dynamic VLAN 22

Switch D Port 3 dynamically joined VLAN 33 Ports 6 dynamically joined VLAN 33

Switch D Port 3 dynamically joined VLAN 33 Ports 6 dynamically joined VLAN 33

FIGURE 122 – VLAN Assignment in GVRP enabled switches. Non GVRP enabled switches can impact VLAN settings on other GVRP enabled switches

An “unknown VLAN” is a VLAN that the switch learns of by GVRP. For example, suppose that port 1 on switch “A” is connected to port 5 on switch “C”. Because switch “A” has VLAN 22 statically configured, while switch “C” does not have this VLAN statically configured, VLAN 22 is handled as an “Unknown VLAN” on port 5 in switch “C”. Conversely, if VLAN 22 was statically configured on switch C, but port 5 was not a member, port 5 would become a member when advertisements for VLAN 22 were received from switch “A”. GVRP provides a per-port join-request option which can be configured.

Page 213 of the GarrettCom MNS-6K user manual — F IGURE 123 – Port settings for GVRP operations
Page 213 · click to enlarge
Page 213

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

VLANs must be disabled in GVRP-unaware devices to allow tagged packets to pass through. A GVRP-aware port receiving advertisements has these options:

  • If there is no static VLAN with the advertised VID on the receiving port, then dynamically create a VLAN with the same VID as in the advertisement, and allow that VLAN’s traffic
  • If the switch already has a static VLAN with the same VID as in the advertisement, and the port is configured to learn for that VLAN, then the port will dynamically join the VLAN and allow that VLAN’s traffic.
  • Ignore the advertisement for that VID and drop all GVRP traffic with that VID
  • Don’t participate in that VLAN

A port belonging to a tagged or untagged static VLAN has these configurable options:

  • Send VLAN advertisements, and also receive advertisements for VLANs on other ports and dynamically join those VLANs
  • Send VLAN advertisements, but ignore advertisements received from other ports
  • Avoid GVRP participation by not sending advertisements and dropping any advertisements received from other devices

Unknown VLAN Mode

Operations

Learn Enables the port to dynamically join any VLAN for which it receives and advertisement, and allows the port to forward the advertisement it receives

Block Prevents the port from dynamically joining a VLAN that is not statically configured on the switch. The port will still forward advertisements that were received by the switch on other ports. Block should typically be used on ports in insecure networks where there is exposure to attack – such as ports where intruders can connect to

Disable Causes the port to ignore and drop all the advertisements it receives from any source

F IGURE 123 – Port settings for GVRP operations

The CLI command “show-vlan” shows a switch’s current GVRP configuration, including the unknown VLANs.

Page 214 of the GarrettCom MNS-6K user manual — F IGURE 125 – Converting a dynamic VLAN to a static VLAN
Page 214 · click to enlarge
Page 214

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# gvrp Magnum6K25(gvrp)## show-vlan ============================================ VLAN ID | NAME | VLAN STATUS ============================================ 1 | Default VLAN | Static Active 2 | Blue | Static Active 10 | dyn10 | Dynamic Active Magnum6K25(gvrp)## FIGURE 124 – Command to check for dynamically assigned VLANs Note that port 10 must be enabled and configured to learn for it to be assigned to the dynamic VLAN. To send advertisements, one or more tagged or untagged static VLANs must be configured on one (or more) switches with GVRP enabled. MNS-6K allows a dynamic VLAN to be converted to a static VLAN. The command to use is Syntax static vlan=<VID> - convert a dynamic VLAN to a static VLAN Note “show vlan type=tag” will display VID in case the VID is not known.

Magnum6K25# gvrp Magnum6K25(gvrp)## show-vlan ============================================ VLAN ID | NAME | VLAN STATUS ============================================ 1 | Default VLAN | Static Active 2 | Blue | Static Active 10 | dyn10 | Dynamic Active Magnum6K25(gvrp)## static vlan=10 Magnum6K25(gvrp)## show-vlan ============================================ VLAN ID | NAME | VLAN STATUS ============================================ 1 | Default VLAN | Static Active 2 | Blue | Static Active 10 | dyn10 | Static Active

VLAN 10 is converted to a static VLAN

F IGURE 125 – Converting a dynamic VLAN to a static VLAN

Page 215 of the GarrettCom MNS-6K user manual — Per-Port Static VLAN Options Per Port “unknown VLAN” (GVRP) configuration
Page 215 · click to enlarge
Page 215

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Per-Port Static VLAN Options Per Port “unknown VLAN” (GVRP) configuration

Tagged or Untagged Auto Forbid

Learn Generate advertisements. Forward advertisements for other VLANs Receive advertisements and dynamically join any advertised VLAN

Receive advertisements and dynamically join any advertised VLAN that has the same VID as the static VLAN

Do not allow the port to become a member of this VLAN

Block Generate advertisements Forward advertisements received from other ports to other VLANs Do not dynamically join any advertised VLAN

Receive advertisements and dynamically join any advertised VLAN that has the same VID

Do not allow the VLAN on this port

Disable Ignore GVRP and drop all GVRP advertisements

Do not allow the VLAN on this port FIGURE 126 – GVRP options

Ignore GVRP and drop all GVRP advertisements

As the above table indicates a port that has a tagged or untagged static VLAN has the option to both generate advertisements and dynamically join other VLANs.

The unknown VLAN parameters are configured on a per interface basis using the

CLI. The tagged, untagged, Auto, and Forbid options are configured in the VLAN context. Since dynamic VLANs operate as tagged VLANs, and it is possible that a tagged port on one device may not communicate with an untagged port on another device, GarrettCom Inc. recommends that you use Tagged VLANs for the static VLANs.

A dynamic VLAN continues to exist on a port for as long as the port continues to receive advertisements of that VLAN from another device connected to that port or until you:

  • Convert the VLAN to a static VLAN
  • Reconfigure the port to Block or Disable
  • Disable GVRP
  • Reboot the switch The time-to-live for dynamic VLANs is 10 seconds. That is, if a port has not received an advertisement for an existing dynamic VLAN during the last 10 seconds, the port removes itself from that dynamic VLAN.
Page 216 of the GarrettCom MNS-6K user manual — Configuring GVRP
Page 216 · click to enlarge
Page 216

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Configuring GVRP

The commands used for configuring GVRP are Syntax show gvrp - shows whether GVRP is disabled, along with the current settings for the maximum

number of VLANs and the current Primary VLAN Syntax gvrp <enable|disable> - enable or disable GVRP Syntax show-vlan – list all the VLANs (including dynamic VLANs) on the switch Syntax set-ports port=<port|list|range> state=<learn|block|disable> - set the state of the port to learn, block or disable for GVRP. Note the default state is disable Syntax static vlan=<VID> - convert a dynamic VLAN to a static VLAN Syntax set-forbid vlan=<tag vlanid> forbid=<port-number|list|range> - sets the forbid GVRP capability on the ports specified Syntax show-forbid – display the ports with GVRP forbid capabilities

Magnum6K25# gvrp Magnum6K25(gvrp)#show gvrp GVRP Status : Enabled Magnum6K25(gvrp)##gvrp disable GVRP is now disabled Magnum6K25(gvrp)##gvrp enable GVRP enabled Magnum6K25(gvrp)## show-vlan ============================================ VLAN ID | NAME | VLAN STATUS ============================================ 1 | Default VLAN | Static Active 2 | Blue | Static Active 10 | dyn10 | Dynamic Active Magnum6K25(gvrp)## static vlan=10 Magnum6K25(gvrp)## show-vlan

Page 217 of the GarrettCom MNS-6K user manual — GVRP Operations Notes
Page 217 · click to enlarge
Page 217

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

============================================ VLAN ID | NAME | VLAN STATUS ============================================ 1 | Default VLAN | Static Active 2 | Blue | Static Active 10 | dyn10 | Static Active Magnum6K25(gvrp)## set-forbid vlan=2 forbid=11-15 Magnum6K25(gvrp)## show-forbid ============================================ VLAN ID | FORBIDDEN PORTS ============================================ 1 | None 2 | 11, 12, 13, 14, 15 FIGURE 127 – GVRP configuration example

GVRP Operations Notes

A dynamic VLAN must be converted to a static VLAN before it can have an IP address. After converting a dynamic VLAN to a static VLAN use the “save” command to save the changes made – on a reboot the changes can be lost without the save command. Within the same broadcast domain, a dynamic VLAN can pass through a device that is not GVRP-aware. This is because a hub or a switch that is not GVRP-aware will flood the GVRP (multicast) advertisement packets out all ports. GVRP assigns dynamic VLANs as tagged VLANs. To configure the VLAN as untagged, first convert the tagged VLAN to a static VLAN. Rebooting a switch with a dynamic VLAN deletes that VLAN. However, the dynamic VLAN re- appears after the reboot if GVRP is enabled and the switch again receives advertisements for that VLAN through a port configured to add dynamic VLANs. By receiving advertisements from other devices running GVRP, the switch learns of static VLANs from those devices and dynamically (automatically) creates tagged VLANs on the links to the advertising devices. Similarly, the switch advertises its static VLANs to other GVRP-aware devices. A GVRP-enabled switch does not advertise any GVRP-learned VLANs out of the port(s) on which it originally learned of those VLANs.

Page 218 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 218 · click to enlarge
Page 218

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

List of commands in this chapter

Syntax show gvrp - shows whether GVRP is disabled, along with the current settings for the maximum

number of VLANs and the current Primary VLAN Syntax gvrp <enable|disable> - enable or disable GVRP Syntax show-vlan – list all the VLANs (including dynamic VLANs) on the switch Syntax set-ports port=<port|list|range> state=<learn|block|disable> - set the state of the port to learn, block or disable for GVRP. Note the default state is disable Syntax static vlan=<VID> - convert a dynamic VLAN to a static VLAN Syntax set-forbid vlan=<tag vlanid> forbid=<port-number|list|range> - sets the forbid GVRP

capability on the ports specified Syntax show-forbid – display the ports with GVRP forbid capabilities

Page 219 of the GarrettCom MNS-6K user manual — j
Page 219 · click to enlarge
Page 219

Chapter 18

18 – SNMP

Managing your network using SNMP

imple Network Management Protocol (SNMP) enables management of the network. There are many software packages which provide a graphical interface and a graphical view of the network and its devices. The graphical interface and view would not be possible without SNMP. SNMP is thus the building block for network management. S

NMP concepts NMP provides the protocol to extract the necessary information from a etworked device and display the information. The information is defined and stored in a Management Information Base (MIB). MIB is the “database” of the network management information.

j

SNMP has evolved over the years (since 1988) using the RFC process. Several RFC’s today define the SNMP standards. The most common standards for SNMP are SNMP v1 (the original version of SNMP); SNMP v2 and more recently SNMP v3. SNMP is a poll based mechanism. SNMP manager polls the managed device for information and display the information retrieved in text or graphical manner. Some definitions related to SNMP are Community string – A text string used to authenticate messages between a management station and an SNMP v1/v2c engine Simple Network Management Protocol (SNMP) – A network management protocol that provides a means to monitor and control network devices, and to manage configurations, statistics collection, performance, and security. Simple Network Management Protocol Version 2c (SNMPv2c) – The second version of SNMP, it supports centralized and distributed network management strategies, and includes improvements in the Structure of Management Information (SMI), protocol operations, management architecture, and security

S S n

Page 220 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 220 · click to enlarge
Page 220

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Simple Network Management Protocol Version 3 (SNMPv3) – The third version of SNMP, the enhancements made to secure access, different levels of access and security. SNMP engine – A copy of SNMP that can either reside on the local or remote device SNMP group – A collection of SNMP users that belong to a common SNMP list that defines an access policy, in which object identification numbers (OIDs) are both read-accessible and write- accessible. Users belonging to a particular SNMP group inherit all of these attributes defined by the group SNMP user – A person for which an SNMP management operation is performed. The user is the person on a remote SNMP engine who receives the information SNMP view – A mapping between SNMP objects and the access rights available for those objects. An object can have different access rights in each view. Access rights indicate whether the object is accessible by either a community string or a user Write view – A view name (not to exceed 64 characters) for each group that defines the list of object identifiers (OIDs) that are able to be created or modified by users of the group Authentication – The process of ensuring message integrity and protection against message replays. It includes both data integrity and data origin authentication Authoritative SNMP engine – One of the SNMP copies involved in network communication designated to be the allowed SNMP engine which protects against message replay, delay, and redirection. The security keys used for authenticating and encrypting SNMPv3 packets are generated as a function of the authoritative SNMP engine's engine ID and user passwords. When an SNMP message expects a response (for example, get exact, get next, set request), the receiver of these messages is authoritative. When an SNMP message does not expect a response, the sender is authoritative Data integrity – A condition or state of data in which a message packet has not been altered or destroyed in an unauthorized manner Data origin authentication – The ability to verify the identity of a user on whose behalf the message is supposedly sent. This ability protects users against both message capture and replay by a different SNMP engine, and against packets received or sent to a particular user that use an incorrect password or security level Encryption – A method of hiding data from an unauthorized user by scrambling the contents of an SNMP packet Group – A set of users belonging to a particular security model. A group defines the access rights for all the users belonging to it. Access rights define what SNMP objects can be read, written to, or created. In addition, the group defines what notifications a user is allowed to receive

Page 221 of the GarrettCom MNS-6K user manual — Standards
Page 221 · click to enlarge
Page 221

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Notification host – An SNMP entity to which notifications (traps and informs) are to be sent Notify view – A view name (not to exceed 64 characters) for each group that defines the list of notifications that can be sent to each user in the group Privacy – An encrypted state of the contents of an SNMP packet where they are prevented from being disclosed on a network. Encryption is performed with an algorithm called CBC-DES (DES- 56) Read view – A view name (not to exceed 64 characters) for each group that defines the list of object identifiers (OIDs) that are accessible for reading by users belonging to the group Security level – A type of security algorithm performed on each SNMP packet. The three levels are: noauth, auth, and priv. noauth authenticates a packet by a string match of the user name. auth authenticates a packet by using either the HMAC MD5 algorithms. priv authenticates a packet by using either the HMAC MD5 algorithms and encrypts the packet using the CBC-DES (DES-56) algorithm Security model – The security strategy used by the SNMP agent. Currently, MNS-6K supports three security models: SNMPv1, SNMPv2c, and SNMPv3

Traps

The traps supported by MNS-6K are as follows: SNMP Traps: Warm Start, Cold Start, Link Up, Link Down, Authentication Failure. RMON Traps: Rising Alarm, Falling Alarm for RMON groups 1, 2, 3, and 9 (Statistics, Events, Alarms, and History) Enterprise Traps: Intruder, S-Ring and LLL

Standards

There are several RFC’s defining SNMP. MNS-6K supports the following RFC’s and standards SNMPv1 standards

  • Security via configuration of SNMP communities
  • Event reporting via SNMP
  • Managing the switch with an SNMP network management tool Supported Standard MIBs include:
  • SNMP MIB-II (RFC 1213)
  • Bridge MIB (RFC 1493) (ifGeneralGroup, ifRcvAddressGroup, ifStackGroup)
Page 222 of the GarrettCom MNS-6K user manual — Configuring SNMP
Page 222 · click to enlarge
Page 222

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

  • RMON MIB (RFC 1757)
  • RMON: groups 1, 2, 3, and 9 (Statistics, Events, Alarms, and History)
  • Version 1 traps (Warm Start, Cold Start, Link Up, Link Down, Authentication Failure, Rising Alarm, Falling Alarm) RFC 1901-1908 – SNMPv2
  • RFC 1901, Introduction to Community-Based SNMPv2. SNMPv2 Working Group
  • RFC 1902, Structure of Management Information for Version 2 of the Simple Network Management Protocol (SNMPv2). SNMPv2 Working Group
  • RFC 1903, Textual Conventions for Version 2 of the Simple Network Management Protocol (SNMPv2). SNMPv2 Working Group
  • RFC 1904, Conformance Statements for Version 2 of the Simple Network Management Protocol (SNMPv2). SNMPv2 Working Group
  • RFC 1905, Protocol Operations for Version 2 of the Simple Network Management Protocol (SNMPv2). SNMPv2 Working Group
  • RFC 1906, Transport Mappings for Version 2 of the Simple Network Management Protocol (SNMPv2)
  • RFC 1907, Management Information Base for Version 2 of the Simple Network Management Protocol (SNMPv2). SNMPv2 Working Group
  • RFC 1908, Coexistence between Version 1 and Version 2 of the Internet-standard Network Management Framework. SNMPv2 Working Group RFC 2271-2275 – SNMPv3
  • RFC 2104, Keyed Hashing for Message Authentication
  • RFC 2271, An Architecture for Describing SNMP Management Frameworks
  • RFC 2272, Message Processing and Dispatching for the Simple Network Management Protocol (SNMP)
  • RFC 2273, SNMPv3 Applications
  • RFC 2274, User-Based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)
  • RFC 2275, View-Based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)

Configuring SNMP

There are several commands and variable which can be set for configuring SNMP. They are listed below. The basic SNMP v1 parameters can be set by referring to the section on System Parameters. Most commands here refer to SNMP v3 commands and how the variables for SNMP v3 can be configured. Syntax snmp – enter the SNMP Configuration mode Syntax set snmp type=<v1|all> - define the version of SNMP to use – the option all supports all versions

(v1, v2 and v3) – v1 restricts SNMP to v1 only. By default – SNMP v1only is enabled Syntax show active-snmp – shows the version of SNMP currently in use

Page 223 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 223 · click to enlarge
Page 223

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax community [write=<write community>] [read=<read community>] [trap=<trap

community>] – set the necessary community strings Syntax authtraps <enable|disable> - enables or disables authentication traps generation Syntax traps <add|delete> type=<Snmp|Rmon|Snmp,Rmon|Enterprise|

Snmp,Enterprise |Rmon,Enterprise|All> ip=<ipaddress> - add v1 traps as well as define the trap receiver Syntax show snmp – displays the SNMP configuration information Syntax mgrip <add|delete> ip=<IPaddress> - adds or deletes a management station, specified by the

IP address, which can query SNMP variables from the switch. This is done to protect the switch from being polled by unauthorized managers. Valid for SNMP v1. Maximum of 5 stations allowed Syntax setvar [sysname|syscontact|syslocation]=<string> sets the system name, contact and

location. All parameters are optional but a user must supply at least one parameter Syntax snmpv3 – enter the SNMP V3 configuration mode – note enable SNMP V3 by using the “set

snmp” command which follows Syntax quickcfg - quick setup for snmpv3 configuration. It automatically configures a default VACM (view-

based access control model). This allows any manager station to access the Magnum 6K switch either via SNMP v1, v2c or v3. The community name is “public”. This command is only intended for first time users and values can be changed by administrators who want more strict access Syntax engineid string=<string> - Every agent has to have an engineID (name) to be able to respond to

SNMPv3 messages. The default engine ID value is “6K_v3Engine”. This command allows the user to change the engine ID Syntax show-authtrap - displays the current value of authentication trap status. Syntax deftrap community=<string> - defines the default community string to be used when sending traps.

When user does not specify the trap community name when setting a trap station using the “trap” command, the default trap community name is used Syntax show-deftrap - displays the current value of default trap Syntax trap <add|delete> id=<id> [type=<v1|v2|inform>] [host=<host-ip>]

[community=<string>] [port=<1-65534>] - define the trap and inform manager stations. The station can receive v1, v2 traps and/or inform notifications. An inform notification is an acknowledgments that a trap has been received. A user can add up to 5 stations. Syntax show-trap [id=<id#>]- shows the configured trap stations in tabular format - id is optional and is

the number corresponding to the trap entry number in the table

Page 224 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 224 · click to enlarge
Page 224

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax com2sec <add|delete> id=<id> [secname=<name>] [source=<source>] [community=<community>] - a part of the View based Access control model (VACM) as defined

in RFC 2275. This specifies the mapping from a source/community pair to a security name. On MNS- 6K, up to 10 entries can be specified Syntax group <add|delete> id=<id> [groupname=<name>] [model=<v1|v2c|usm>] [com2secid=<com2sec-id>] - a part of the View based Access

control model (VACM) as defined in RFC 2275. This command defines the mapping from sec model or a sec name to a group. A sec model is one of v1, v2c, or usm. On MNS-6K, up to 10 entries can be specified Syntax show-group [id=<id>] - display all or specific group entries - id is optional and is the number

corresponding to the group entry number in the table Syntax view <add|delete> id=<id> [viewname=<name>] [type=<included|excluded>]

[subtree=<oid>] [mask=<hex-string>] - a part of the View based Access control model (VACM) as defined in RFC 2275. This command defines a manager or group or manager stations what it can access inside the MIB object tree. On MNS-6K, up to 10 entries can be specified Syntax show-view [id=<id>] - display all or specific view entries - id is optional and is the number

corresponding to the view entry number in the table Syntax user <add|delete> id=<id> [username=<name>] [usertype=<readonly|readwrite>] [authpass=<pass-phrase>] [privpass=<pass-phrase>] [level=<noauth|auth|priv>] [subtree=<oid>] for

quickly adding or deleting v3 USM based security, this command adds user entries. MNS-6K allows up to 5 users to be added. Right now, the MNS-6K agent only support noauth and auth-md5 for v3 authentication and auth-des for priv authentication Syntax show-user [id=<id>] - display all or specific view entries - id is optional and is the number

corresponding to the view entry number in the table

Magnum6K25# set snmp type=v1 Magnum6K25# show active-snmp 6K SNMP Agent supports v1 only. Magnum6K25# show snmp SNMP CONFIGURATION INFORMATION SNMP Get Community Name : public SNMP Set Community Name : private SNMP Trap Community Name : public AuthenTrapsEnableFlag : disabled SNMP Access Status : enabled

Page 225 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 225 · click to enlarge
Page 225

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

SNMP MANAGERS INFO SNMP TRAP STATIONS INFO Magnum6K25# snmp Magnum6K25(snmp)## community write=private read=public SNMP Read community name successfully set SNMP Write community name successfully set Magnum6K25(snmp)## show snmp SNMP CONFIGURATION INFORMATION SNMP Get Community Name : public SNMP Set Community Name : private SNMP Trap Community Name : public AuthenTrapsEnableFlag : enabled SNMP Access Status : enabled SNMP MANAGERS INFO SNMP TRAP STATIONS INFO Magnum6K25(snmp)## mgrip add ip=192.168.1.111 Manager IP Address added successfully Magnum6K25(snmp)## mgrip add ip=192.168.1.222 Manager IP Address added successfully Magnum6K25(snmp)# show snmp SNMP CONFIGURATION INFORMATION SNMP Get Community Name : public SNMP Set Community Name : private SNMP Trap Community Name : public AuthenTrapsEnableFlag : disabled SNMP Access Status : enabled SNMP MANAGERS INFO IP Address = 192.168.1.111 IP Address = 192.168.1.222

Use this command for SNMP v1 managers. Without this command SNMP v1 managers will not be able to manage the switches. Not needed for SNMP v3. Note – maximum of 5 stations allowed.

Managers added are displayed under the SNMP information by using the “show snmp” command

Page 226 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 226 · click to enlarge
Page 226

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

SNMP TRAP STATIONS INFO Magnum6K25(snmp)## traps add type=Snmp,Rmon ip=192.168.1.2 Successfully Added. Magnum6K25(snmp)## show snmp SNMP CONFIGURATION INFORMATION SNMP Get Community Name : public SNMP Set Community Name : private SNMP Trap Community Name : public AuthenTrapsEnableFlag : enabled SNMP Access Status : enabled SNMP MANAGERS INFO IP Address = 192.168.1.111 IP Address = 192.168.1.222 SNMP TRAP STATIONS INFO IP Address = 192.168.1.2 Trap Type = SNMP,RMON Magnum6K25(snmp)# exit Magnum6K25# show snmp SNMP CONFIGURATION INFORMATION SNMP Get Community Name : public SNMP Set Community Name : private SNMP Trap Community Name : public AuthenTrapsEnableFlag : enabled SNMP Access Status : enabled SNMP MANAGERS INFO IP Address = 192.168.1.111 IP Address = 192.168.1.222 SNMP TRAP STATIONS INFO IP Address = 192.168.1.2 Trap Type = SNMP,Enterprise Magnum6K25# set snmp type=all SNMP version support is set to "v1, v2c and v3" Magnum6K25# show active-snmp

Managers added are displayed under the SNMP information by using the “show snmp” command

Page 227 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 227 · click to enlarge
Page 227

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

6K SNMP Agent supports all (v1/v2c/v3) versions. Magnum6K25# show snmp

SNMP v3 Configuration Information =============================

System Name : Magnum6K25 System Location : Fremont, CA System Contact : support@garrettcom.com Authentication Trap : Disabled Default Trap Comm. : public V3 Engine ID : 6K_v3Engine Magnum6K25# snmpv3

Switch over to SNMPv3 from this point forward

Magnum6K25(snmpv3)## setvar sysname=my_m6k syscontact=admin syslocation=lab Magnum6K25(snmpv3)# quickcfg This will enable default VACM. Do you wish to proceed? [ 'Y' or 'N' ] Y Quick configuration done, default VACM enabled Magnum6K25(snmpv3)## engineid string=Magnum6K Engine ID is set successfully Magnum6K25(snmpv3)## authtrap enable Authentication trap status is set successfully Magnum6K25(snmpv3)## show-authtrap Authentication Trap Status: Enabled Magnum6K25(snmpv3)## deftrap community=mysecret Default trap community is set successfully Magnum6K25(snmpv3)## show-deftrap Default Trap Community : public Magnum6K25(snmpv3)## trap add id=1 type=v1 host=10.21.1.100 Entry is added successfully

Max limit of system variables is 15 characters

Page 228 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 228 · click to enlarge
Page 228

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25(snmpv3)## show-trap ID Trap Type Host IP Community Port ================================================================ 1 v1 10.21.1.100 -- -- 2 -- 3 -- 4 -- 5 -- Magnum6K25(snmpv3)## show-trap id=1 Trap ID : 1 Trap Type : v1 Host IP : 10.21.1.100 Community : -- Auth. Type : -- Magnum6K25(snmpv3)## com2sec add id=1 secname=public source=default community=public Entry is added successfully Magnum6K25(snmpv3)## com2sec add id=2 ERROR: "secname" parameter is required for "add" directive Magnum6K25(snmpv3)## com2sec add id=2 secname=BCM Entry is added successfully Magnum6K25(snmpv3)## show-com2sec ID Sec. Name Source Community ================================================== 1 public default public 2 BCM default public 3 -- -- -- 4 -- -- -- 5 -- -- -- 6 -- -- -- 7 -- -- -- 8 -- -- -- 9 -- -- -- 10 -- -- -- Magnum6K25(snmpv3)## show-com2sec id=2 Com2Sec ID : 2 Security Name : BCM Source : default Community : public

Page 229 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 229 · click to enlarge
Page 229

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25(snmpv3)## group add id=1 groupname=v1 model=v1 com2secid=1 Entry is added successfully Magnum6K25(snmpv3)## show-group ID Group Name Sec. Model Com2Sec ID ================================================== 1 v1 v1 1 2 public v2c 1 3 public usm 1 4 -- -- -- 5 -- -- -- 6 -- -- -- 7 -- -- -- 8 -- -- -- 9 -- -- -- 10 -- -- -- Magnum6K25(snmpv3)## show-group id=1 Group ID : 1 Group Name : v1 Model : v1 Com2Sec ID : 1 Magnum6K25(snmpv3)## view add id=1 viewname=all type=included subtree=.1 Entry is added successfully Magnum6K25(snmpv3)## show-view ID View Name Type Subtree Mask =========================================== 1 all included .1 ff 2 -- 3 -- 4 -- 5 -- 6 -- 7 -- 8 -- 9 -- 10 -- Magnum6K25(snmpv3)## show-view id=1 View ID : 1 View Name : all Type : included Subtree : .1 Mask : ff

Page 230 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 230 · click to enlarge
Page 230

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25(snmpv3)## access add id=1 accessname=v1 model=v1 level=noauth read=1 writ e=none notify=none Entry is added successfully Magnum6K25(snmpv3)## show-access ID View Name Model Level R/View W/View N/View Context Prefix ============================================================== 1 v1 v1 noauth 1 none none "" exact 2 -- 3 -- 4 -- 5 -- 6 -- 7 -- 8 -- 9 -- 10 -- Magnum6K25(snmpv3)## show-access id=1 Access ID : 1 Access Name : v1 Sec. Model : v1 Sec. Level : noauth Read View ID : 1 Write View ID : none Notify View ID : none Context : "" Prefix : exact Magnum6K25(snmpv3)## user add id=1 username=jsmith usertype=readwrite authpass=something Entry is added successfully Magnum6K25(snmpv3)## show-user ID User Name UType AuthPass PrivPass AType Level Subtree ======================================================================= 1 jsmith RW something MD5 auth 2 -- 3 -- 4 -- 5 -- Magnum6K25(snmpv3)## show-user id=2 ERROR: Entry is not active

Page 231 of the GarrettCom MNS-6K user manual — Configuring RMON
Page 231 · click to enlarge
Page 231

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25(snmpv3)## show-user id=1 User ID : 1 User Name : jsmith User Type : read-write Auth. Pass something Priv. Pass : Auth. Type : MD5 Auth. Level : auth Subtree : Magnum6K25(snmpv3)## exit Magnum6K25# show snmp SNMPv3 Configuration Information ================================== System Name : Magnum6K25 System Location : Fremont, CA System Contact : support@garrettcom.com Authentication Trap : Enabled Default Trap Comm. : public V3 Engine ID : 6K_v3Engine Magnum6K25# FIGURE 128 – Configuring SNMP – most of the command here are SNMP v3 commands

Configuring RMON

The switch supports RMON (Remote Monitoring) on all connected network segments. This allows for troubleshooting and optimizing your network. The Magnum 6K family of switches provides hardware-based RMON counters. The switch manager or a network management system can poll these counters periodically to collect the statistics in a format that complies with the RMON MIB definition. The following RMON groups are supported:

  • Ethernet Statistics Group - maintains utilization and error statistics for the switch port being monitored.
  • History Group – gathers and stores periodic statistical samples from previous Statistics Group.
  • Alarm Group – allows a network administrator to define alarm thresholds for any MIB variable.
  • Log and Event Group – allows a network administrator to define actions based on alarms. SNMP Traps are generated when RMON Alarms are triggered.
Page 232 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 232 · click to enlarge
Page 232

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

The following RMON communities, when defined, enable the specific RMON group as show above. Syntax rmon – enter the RMON configuration mode to setup RMON groups and communities Syntax history def-owner=<string> def-comm=<string> - define the RMON history group and the

community string associated with the group Syntax statistics def-owner=<string> def-comm=<string>- define the RMON statistics group and

the community string associated with the group Syntax alarm def-owner=<string> def-comm=<string> - define the RMON alarm group and the

community string associated with the group Syntax event def-owner=<string> def-comm=<string> - define the RMON event group and the

community string associated with the group Syntax show rmon <stats|hist|event|alarm> - list the specific RMON data as defined by the group

type Magnum6K25# rmon Magnum6K25(rmon)## event def-owner=test def-comm=somestring RMON Event Default Owner is set RMON Event Default Community is set Magnum6K25(rmon)## show rmon event RMON Event Default Owner : test RMON Event Default Community : somestring Magnum6K25(rmon)## exit Magnum6K25# FIGURE 129 – Configuring RMON groups

List of commands in this chapter

Syntax snmp – enter the SNMP Configuration mode

Page 233 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 233 · click to enlarge
Page 233

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax snmpv3 – enter the SNMP V3 configuration mode – note enable SNMP V3 by using the “set

snmp” command which follows Syntax show active-snmp – shows the version of SNMP currently in use Syntax community [write=<write community>] [read=<read community>] [trap=<trap

community>] – set the necessary community strings Syntax authtraps <enable|disable> - enables or disables authentication traps generation Syntax traps <add|delete> type=<Snmp|Rmon|Snmp,Rmon|Enterprise|

Snmp,Enterprise |Rmon,Enterprise|All> ip=<ipaddress> - add v1 traps as well as define the trap receiver Syntax mgrip <add|delete> ip=<IPaddress> - adds or deletes a management station, specified by the

IP address, which can query SNMP variables from the switch. This is done to protect the switch from being polled by unauthorized managers. Valid for SNMP v. Maximum of five stations allowed. Syntax set snmp type=<v1|all> - define the version of SNMP to use – the option all supports all versions

(v1, v2 and v3) – v1 restricts SNMP to v1 only. By default – SNMP v1only is enabled Syntax show snmp – displays the SNMP configuration information Syntax setvar [sysname|syscontact|syslocation]=<string> sets the system name, contact and

location. All parameters are optional but a user must supply at least one parameter Syntax quickcfg - quick setup for snmpv3 configuration. It automatically configures a default VACM (view-

based access control model). This allows any manager station to access the Magnum 6K switch either via SNMP v1, v2c or v3. The community name is “public”. This command is only intended for first time users and values can be changed by administrators who want more strict access Syntax engineid string=<string> - Every agent has to have an engineID (name) to be able to respond to

SNMPv3 messages. The default engine ID value is “6K_v3Engine”. This command allows the user to change the engine ID Syntax authtrap <enable|disable> - enables or disables authentication traps generation Syntax show-authtrap - displays the current value of authentication trap status. Syntax deftrap community= - defines the default community string to be used when sending traps.

When user does not specify the trap community name when setting a trap station using the “trap” command, the default trap community name is used Syntax show-deftrap - displays the current value of default trap

Page 234 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 234 · click to enlarge
Page 234

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax trap <add|delete> id=<id> [type=<v1|v2|inform>] [host=<host-ip>]

[community=<string>] [port=<1-65534>] - define the trap and inform manager stations. The station can receive v1, v2 traps and/or inform notifications. An inform notification is an acknowledgments that a trap has been received. A user can add up to 5 stations. Syntax show-trap [id=<id#>]- shows the configured trap stations in tabular format - id is optional and is

the number corresponding to the trap entry number in the table Syntax com2sec <add|delete> id=<id> [secname=<name>] [source=<source>] [community=<community>] - a part of the View based Access control model (VACM) as defined

in RFC 2275. This specifies the mapping from a source/community pair to a security name. On MNS- 6K, up to 10 entries can be specified Syntax group <add|delete> id=<id> [groupname=<name>] [model=<v1|v2c|usm>] [com2secid=<com2sec-id>] - a part of the View based Access

control model (VACM) as defined in RFC 2275. This command defines the mapping from sec model or a sec name to a group. A sec model is one of v1, v2c, or usm. On MNS-6K, up to 10 entries can be specified Syntax show-group [id=<id>] - display all or specific group entries - id is optional and is the number

corresponding to the group entry number in the table Syntax view <add|delete> id=<id> [viewname=<name>] [type=<included|excluded>]

[subtree=<oid>] [mask=<hex-string>] - a part of the View based Access control model (VACM) as defined in RFC 2275. This command defines a manager or group or manager stations what it can access inside the MIB object tree. On MNS-6K, up to 10 entries can be specified Syntax show-view [id=<id>] - display all or specific view entries - id is optional and is the number

corresponding to the view entry number in the table Syntax user <add|delete> id=<id> [username=<name>] [usertype=<readonly|readwrite>] [authpass=<pass-phrase>] [privpass=<pass-phrase>] [level=<noauth|auth|priv>] [subtree=<oid>] for

quickly adding or deleting v3 USM based security, this command adds user entries. MNS-6K allows up to 5 users to be added. Right now, the MNS-6K agent only support noauth and auth-md5 for v3 authentication and auth-des for priv authentication Syntax show-user [id=<id>] - display all or specific view entries - id is optional and is the number

corresponding to the view entry number in the table Syntax rmon – enter the RMON configuration mode to setup RMON groups and communities Syntax history def-owner=<string> def-comm=<string> - define the RMON history group and the

community string associated with the group

Page 235 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 235 · click to enlarge
Page 235

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax statistics def-owner=<string> def-comm=<string>- define the RMON statistics group and

the community string associated with the group Syntax alarm def-owner=<string> def-comm=<string> - define the RMON alarm group and the

community string associated with the group Syntax event def-owner=<string> def-comm=<string> - define the RMON event group and the

community string associated with the group Syntax show rmon <stats|hist|event|alarm> - list the specific RMON data as defined by the group

type

Page 236 of the GarrettCom MNS-6K user manual — Alarm Relays
Page 236 · click to enlarge
Page 236

Chapter 19

19 – Miscellaneous Commands

Improving productivity and manageability

here are several features built into the Magnum 6K family of switches which help with the overall productivity and manageability of the switch. These items are examined individually in this chapter. T

Alarm Relays

In a wiring closet, it would be helpful if there was a visual indication for faults on components on the network. Normally, these would be performed by LED’s. While the Magnum 6K family of switches has the necessary LED’s to provide the information needed, it also has a provision for tripping or activating an external relay to electrically trigger any circuit desired. These could be an indicator light, a flashing strobe light, an audible alarm or any other such devices. The Magnum 6K family of switches has a software (optional) controlled relay contact that can be use to report alarm conditions. The relay is held open (no connection) in normal circumstances and will go to close position during alarm conditions. Two types of alarm signals are defined in the alarm system.

  • SUSTAINED
  • MOMENTARY The SUSTAINED mode is used to report a continuing error condition. The MOMENTARY mode is used to report a single event. The following pre-defined events are currently supported on the MNS-6K and the relay which can be triggered by software:
Page 237 of the GarrettCom MNS-6K user manual — Event ID Event Description Signal Type
Page 237 · click to enlarge
Page 237

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Event ID Event Description Signal Type

1 S-RING OPEN SUSTAINED

2 Cold Start MOMENTARY

3 Warm Start MOMENTARY

4 Link Up MOMENTARY

5 Link Down MOMENTARY

6 Authentication Failure MOMENTARY

7 RMON Rising Alarm9 MOMENTARY

8 RMON Falling Alarm MOMENTARY

9 Intruder Alarm MOMENTARY

10 Link Loss Learn Triggered MOMENTARY

11 Broadcast Storm Detected MOMENTARY

12 STP/RSTP Reconfigured MOMENTARY

FIGURE 130 – Predefined conditions for the relay

The S-RING open condition generates a sustained relay contact close. The relay will stay closed during the period which the S-RING is in OPEN condition. The relay will revert to closed position when the S-RING goes to CLOSED position. This information is covered in more details in Chapter 11 on S-Ring and Link-Loss-Learn. To customize these capabilities, the MNS-6K provides additional software capabilities and commands for configuring the behavior. They are Syntax alarm – enter the alarm configuration mode Syntax add event=<event-id|list|range|all> - enables alarm action in response to the specified event ID

9 The RMON settings are when the RMON thresholds are crossed and hence indicated as RMON rising or falling – indicating the threshold has been crossed . While there is no specific command to view and change the specific RMON variables, the RMON discussion is in Chapter 16. Best way to set RMON values will be via using the web interface or a Management system such as Castle Rock’s SNMPc™

Page 238 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 238 · click to enlarge
Page 238

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax period time=<1..10> - sets the duration of relay action for the momentary type signal. This may be

needed to adjust to the behavior of the circuit or relay. Default is 3 seconds. Time is in seconds Syntax del event=<event-id|list|range|all> - disables alarm action in response to the specified event ID Syntax alarm <enable|disable> - globally enables or disables the alarm action Syntax show alarm - displays the current status of Alarm system

Magnum6K25# alarm Magnum6K25(alarm)## add event=2 Alarm Event(s) Added: 2 Magnum6K25(alarm)## add event=1-5 Event 2 is Already Enabled. Alarm Event(s) Added: 1, 3, 4, 5 Magnum6K25(alarm)## add event=6,8 Alarm Event(s) Added: 6, 8 Magnum6K25(alarm)## add event=all Event 1 is Already Enabled. Event 2 is Already Enabled. Event 3 is Already Enabled. Event 4 is Already Enabled. Event 5 is Already Enabled. Event 6 is Already Enabled. Event 8 is Already Enabled. Alarm Event(s) Added: 7, 9, 10, 11, 12 Magnum6K25(alarm)## del event=2 Alarm Event(s) Deleted: 2 Magnum6K25(alarm)## period time=5 Relay closure Time Set. Magnum6K25(alarm)## show alarm Alarm Events Configuration Alarm Status: DISABLED Relay Closure Time Period: 5 Seconds EventId Description Mode 1 S-RING OPEN SUSTAINED 2 Cold Start NOT ENABLED 3 Warm Start MOMENTARY 4 Link Up MOMENTARY

Page 239 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 239 · click to enlarge
Page 239

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

5 Link Down MOMENTARY 6 Authentication Failure MOMENTARY 7 RMON Raising Alarm MOMENTARY 8 RMON Falling Alarm MOMENTARY 9 Intruder Alarm MOMENTARY 10 Link Loss Learn Triggered MOMENTARY 11 Broadcast Storm Detected MOMENTARY 12 STP/RSTP Reconfigured MOMENTARY Magnum6K25(alarm)## add event=2 Alarm Event(s) Added: 2 Magnum6K25(alarm)## show alarm Alarm Events Configuration Alarm Status: DISABLED Relay Closure Time Period: 5 Seconds EventId Description Mode 1 S-RING OPEN SUSTAINED 2 Cold Start MOMENTARY 3 Warm Start MOMENTARY 4 Link Up MOMENTARY 5 Link Down MOMENTARY 6 Authentication Failure MOMENTARY 7 RMON Raising Alarm MOMENTARY 8 RMON Falling Alarm MOMENTARY 9 Intruder Alarm MOMENTARY 10 Link Loss Learn Triggered MOMENTARY 11 Broadcast Storm Detected MOMENTARY 12 STP/RSTP Reconfigured MOMENTARY Magnum6K25(alarm)## alarm enable Alarm system Enabled Magnum6K25(alarm)## show alarm Alarm Events Configuration Alarm Status: ENABLED Relay Closure Time Period: 5 Seconds EventId Description Mode 1 S-RING OPEN SUSTAINED 2 Cold Start MOMENTARY 3 Warm Start MOMENTARY 4 Link Up MOMENTARY 5 Link Down MOMENTARY 6 Authentication Failure MOMENTARY 7 RMON Raising Alarm MOMENTARY

Page 240 of the GarrettCom MNS-6K user manual — Email
Page 240 · click to enlarge
Page 240

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

8 RMON Falling Alarm MOMENTARY 9 Intruder Alarm MOMENTARY 10 Link Loss Learn Triggered MOMENTARY 11 Broadcast Storm Detected MOMENTARY 12 STP/RSTP Reconfigured MOMENTARY Magnum6K25(alarm)## alarm disable Alarm system Disabled Magnum6K25(alarm)## del event=1,3,5,7 Alarm Event(s) Deleted: 1, 3, 5, 7 Magnum6K25(alarm)## show alarm Alarm Events Configuration Alarm Status: DISABLED Relay Closure Time Period: 5 Seconds EventId Description Mode 1 S-RING OPEN NOT ENABLED 2 Cold Start MOMENTARY 3 Warm Start NOT ENABLED 4 Link Up MOMENTARY 5 Link Down NOT ENABLED 6 Authentication Failure MOMENTARY 7 RMON Raising Alarm NOT ENABLED 8 RMON Falling Alarm MOMENTARY 9 Intruder Alarm MOMENTARY 10 Link Loss Learn Triggered MOMENTARY 11 Broadcast Storm Detected MOMENTARY 12 STP/RSTP Reconfigured MOMENTARY Magnum6K25(alarm)## exit Magnum6K25# FIGURE 131 – Setting up the external electrical relay and alerts

Email

SMTP (RFC 821) is a TCP/IP protocol used in sending email. However, since it is limited in its ability to queue messages at the receiving end, it’s usually used with one of two other protocols, POP3 or Internet Message Access Protocol (IMAP) that lets the user save messages in a server mailbox and download them as needed from the server. In other words, users typically use a program that uses SMTP for sending emails (out going – e.g. replying to an email message) and

Page 241 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 241 · click to enlarge
Page 241

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

either POP3 or IMAP for receiving messages that have been arrived from the outside world. While SMTP (and its related protocols such as POP3, IMAP etc.) are useful transports for sending and receiving emails, it is extremely beneficial for a network administrator to receive emails in case of faults and alerts. The Magnum 6K family of switches can be setup to send an email alert when a trap is generated.

If this capability is used, please ensure that SPAM filters and other filters are not set to delete these emails. GarrettCom Inc. recommends that a rule be setup on the mail server so that all emails indicating SNMP faults are automatically stored in a folder or redirected to the necessary administrators. The SNMP alerts can be configured using MNS-6K for the following:

  • Send email alert according to the configuration rules when a specific event category happens
  • Send email alert according to the configuration rules when a specific trap SNMP trap category happens
  • Provide configuration and customization commands for users to specify SMTP server to connect to, TCP ports, user recipients and filters

The SMTP alerts provide the following capabilities:

  • SMTP alerts can be enabled or disabled globally
  • User can define a global default SMTP server identified by its IP address, TCP port and retry count
  • User can add up to five SMTP alert recipients. Each recipient is identified by an ID and email address. The email address needs to be a valid address and can be an alias setup for distribution to a larger audience
  • Filters are provided for each recipient to allow only certain categories of traps and events be sent by email
  • Each recipient can have its own SMTP server and TCP port number, if this is not defined on a certain recipient, the default SMTP server and TCP port number is used Syntax smtp – configure the SNMP alerts to be sent via email Syntax show smtp <config|recipients> - config – displays the current SMTP global settings and

recipients displays the currently configured recipients of email alerts Syntax add id=<1-5> email=<email-addr> [traps=<all|none|S|R|E>]

[events=<all|none|I|A|C|F|D>] [ip=<ip-addr>] [port=<1-65535>] id – [mandatory] the recipient ID - range from 1 to 5. MNS-6K allows a maximum of 5

recipients

Page 242 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 242 · click to enlarge
Page 242

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

email – [mandatory] email address of the recipient traps – [optional] this is the trap filter. If value is “all”, all traps of any type will be sent to

this recipient. If value is none, no traps are sent to this recipient. Value can also be a combination of ‘S’ (SNMP), ‘R’ (RMON) and ‘E’ (ENTERPRISE). For example, trap=SR means that SNMP and RMON traps will be sent via email to the recipient. If this option is not defined, the recipient will have a default value of “all” events – [optional] this is the event filter. Value can be “all” - all event severity types will

be sent to recipient, “none” - no event will be sent to recipient or a combination of ‘I’ (informational), ‘A’ (activity), ‘C’ (critical), ‘F’ (fatal) and ‘D’ (debug). With “event=ACF” implies that events of severity types activity, critical and fatal will be sent to recipients by email. If this option is not defined, a value of “all” is taken ip – [optional] SMTP server IP address. This is the SMTP server to connect to for this

particular user. If this option is not defined, the global/default SMTP server is used port – [optional] TCP port of the SMTP server. If this is not defined, the global default

TCP port is used Syntax delete id=<1-5> - delete the specific id specified. The deleted id no longer receives the traps via email.

The id is added using the “add” command Syntax sendmail server=<ip-addr> to=<email-addr> from=<email-addr>

subject=<string> body=<string> - customize (and also to send a test email to check SMTP settings) the email sent out by specifying the email subject field, server address, to field and the body of the text. See example fo the body of the text message later in this chapter server – [mandatory] SMTP server IP v4 address. to – [mandatory] the recipient email address from – [mandatory] the sender email address. subject – [mandatory] email subject or title body – [mandatory] email body Syntax server ip=<ip-addr> [port=<1-65535>] [retry=<0-3>] – configure the global SMTP server

settings ip – [mandatory] SMTP server IP address port – [mandatory] TCP port to be used for SMTP communications – default is 25

Page 243 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 243 · click to enlarge
Page 243

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

retry – [optional] specifies how many times to retry if an error occurs when sending email.

Range from 0 to 3. Default is 0. Syntax smtp <enable|disable> - enables or disables SMTP to send SNMP alerts by email

Magnum6K25# smtp Magnum6K25(smtp)## show smtp config SMTP Global Configuration ======================================== Status : Disabled SMTP Server IP : 67.109.247.195 SMTP Server Port : 25 Retry Count : 3 Magnum6K25(smtp)## show smtp recipients ID E-mail Address SMTP Server Port Traps Events =========================================================== 1 rk@gci,sys@gci.com 67.109.247.195 25 All All 2 -- 3 -- 4 -- 5 -- Magnum6K25(smtp)## add id=2 email=jsmith@garrettcom.com traps=S events=CF Recipient successfully added Magnum6K25(smtp)## show smtp recipients ID E-mail Address SMTP Server Port Traps Events =========================================================== 1 rk@gci,sys@gci.com 67.109.247.195 25 All All 2 jsmith@gci.com 67.109.247.195 25 S CF 3 -- 4 -- 5 -- Magnum6K25(smtp)## delete id=2 Recipient successfully deleted Magnum6K25(smtp)## show smtp recipients ID E-mail Address SMTP Server Port Traps Events =========================================================== 1 rk@gci,sys@gci.com 67.109.247.195 25 All All 2 -- 3 -- 4 --

Jsmith will only receive Critical or Fatal SNMP traps

Page 244 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 244 · click to enlarge
Page 244

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

5 -- Magnum6K25(smtp)## add id=2 email=jsmith@garrettcom.com traps=S events=CF ip=192.168.10.13 Recipient successfully added Magnum6K25(smtp)## show smtp recipients ID E-mail Address SMTP Server Port Traps Events =========================================================== 1 rk@gci,sys@gci.com 67.109.247.195 25 All All 2 jsmith@gci.com 192.168.10.13 25 S CF 3 -- 4 -- 5 -- Magnum6K25(smtp)## sendmail server=10.21.1.2 to=jack@garrettcom.com from=support@garrettcom.com subject=test body=hello Magnum6K25(smtp)## smtp enable

Jsmith will receive Critical and Fatal SNMP traps on a different SMTP server than the other users. You may want to do that if you expect a higher traffic load and don’t want to throttle a SMTP server

A test email is sent to Jack to test email connectivity. This email will not work as SMTP was disabled. The sendmail command after SMTP is enabled will work.

SMTP Alert is enabled. Magnum6K25(smtp)## sendmail server=10.21.1.2 to=jack@garrettcom.com from=support@garrettcom.com subject=test body=hello

Magnum6K25(smtp)## show smtp config SMTP Global Configuration ======================================== Status : Enabled SMTP Server IP : 67.109.247.195 SMTP Server Port : 25 Retry Count : 3 Magnum6K25(smtp)## smtp disable SMTP Alert is disabled. Magnum6K25(smtp)## show smtp config SMTP Global Configuration ======================================== Status : Disabled SMTP Server IP : 67.109.247.195 SMTP Server Port : 25 Retry Count : 3

Page 245 of the GarrettCom MNS-6K user manual — Serial Connectivity
Page 245 · click to enlarge
Page 245

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25(smtp)## exit Magnum6K25# FIGURE 132 – setting SMTP to receive SNMP trap information via email

Email alerts can be forwarded to be received by other devices such as Cell phones, pagers etc. Most interfaces to SMTP are already provided by the cell phone service provider or the paging service provider.

Serial Connectivity

When using the serial connectivity with applications such as Hyper terminal etc. it may be necessary to optimize the character delays so that the FIFO buffer used in the GarrettCom Magnum 6K family of switches is not overrun. The important parameters to set for any serial connectivity software is to set the line delay to be 500 milliseconds and the character delay to be 50 milliseconds. For example, using Hyper Terminal this can be set under File Æ Properties and when the Properties sheet is open, click on the ASCII Setup button and in the Line Delay entry box enter in 500 and in the Character Delay entry box enter in 50 as shown below.

GarrettCom MNS-6K — Serial Connectivity diagram (page 245)
Fig. 20 · Serial Connectivity

FIGURE 133 – Optimizing serial connection (shown for Hyper Terminal on Windows XP). The highlighted fields are the ones to change as described

Page 246 of the GarrettCom MNS-6K user manual — Miscellaneous commands
Page 246 · click to enlarge
Page 246

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Miscellaneous commands

Some of the commands listed below may be useful in repeating several commands over and over again. They are Syntax !! – repeat the last command Syntax !<n> - repeat the “n”th command (as indicated by a show history) Syntax show history – show the last 25 commands executed – if less than 25 commands are executed, only

those commands executed are shown

If the user logs out or if the switch times out – the history is erased. The history count restarts when the user logs in again Syntax <Up-arrow> - every time the key is pressed, the last command is printed on the screen but not executed.

This allows for editing errors made in typing Syntax <Down-arrow> - opposite of Up-arrow key Syntax show version – displays the version of MNS-6K being used

Magnum6K25# show version MNS-6K Ver: 3.6 Date:Oct 20 2006 Time:17:22:35 Build ID 1161390154 Magnum6K25# show setup Version : Magnum 6K25 build 3.6 Oct 20 2006 17:22:35 MAC Address : 00:20:06:25:ed:80 IP Address : 67.109.247.197 Subnet Mask : 255.255.255.224 Gateway Address : 67.109.247.193 CLI Mode : Manager System Name : pierpaolo System Description : 25 Port Modular Ethernet Switch System Contact : support@garrettcom.com System Location : HQ, Fremont, CA System ObjectId : 1.3.6.1.4.1.553.12.6 Magnum6K25# show serial

Page 247 of the GarrettCom MNS-6K user manual — Prompt
Page 247 · click to enlarge
Page 247

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Baud Rate : 38400 Data : 8 Parity : No Parity Stop : 1 Flow Control : None Magnum6K25# show history 1 : show version 2 : show setup 3 : show serial 4 : show history Magnum6K25# !1 show version MNS-6K Ver: 3.6 Date:Oct 20 2006 Time:17:22:35 Build ID 1161390154 Magnum6K25# FIGURE 134 – History commands

Prompt

Setting a meaningful host prompt can be useful when a network administrator is managing multiple switches and has multiple telnet or console sessions open at the same time. To facilitate this, MNS-6K allows administrators to define custom prompts. The command to set a prompt is

Syntax set prompt <prompt string> The length of the prompt is limited to 60 characters There are predefined variables which can be used to set the prompt. These are $n : System Name $c : System Contact $l : System Location $i : System IP $m : System MAC $v : Version $$ : $ Character $r : New Line $b : Space A few examples on how the system prompt can be setup is shown below.

Page 248 of the GarrettCom MNS-6K user manual — Ping
Page 248 · click to enlarge
Page 248

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# snmp Magnum6K25(snmp)## setvar sysname=Core System variable(s) set successfully Magnum6K25(snmp)## exit Magnum6K25# set prompt $n Core# set prompt $n$b$i Core 192.168.5.5# set prompt $n$b$i$b Core 192.168.5.5 # snmp Core 192.168.5.5 (snmp)## setvar sysname=Magnum6K25 System variable(s) set successfully Core 192.168.5.5 (snmp)## exit Core 192.168.5.5 # set prompt $b$b$i$b 192.168.5.5 # set prompt $n$b$i$b Magnum6K25 192.168.5.5 # Magnum6K25 192.168.5.5 # Magnum6K25 192.168.5.5 # Magnum6K25 192.168.5.5 # set prompt Some$bthing$i Some thing192.168.5.5# set prompt Some$bthing$b$i Some thing 192.168.5.5# FIGURE 135 – Setting custom prompts

Ping

Ping command can be used from MNS-6K to test connectivity to other devices as well as checking to see if the IP address is setup correctly. The command is Syntax ping <ipaddress> [count=<1-999>] [timeout=<1-256>] – use the ping command to test

Magnum6K25# ping 67.109.247.202 67.109.247.202 is alive, count 1, time = 40ms Magnum6K25# ping 67.109.247.202 count=3 67.109.247.202 is alive, count 1, time = 20ms 67.109.247.202 is alive, count 2, time = 20ms 67.109.247.202 is alive, count 3, time = 40ms Magnum6K25# FIGURE 136 – Using the ping command

connectivity

Page 249 of the GarrettCom MNS-6K user manual — System Events
Page 249 · click to enlarge
Page 249

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Many devices do not respond to ping or block ping commands. Make sure that

the target device does respond or the network does allow the ping packets to propagate through.

FTP modes

The file transfer protocol or ftp is supported on MNS-6K. MNS-6K supports normal ftp as well as passive ftp. Passive FTP is used by many companies today to work with firewall policies and other security policies set by companies. The commands for setting the type of ftp are:

Syntax set ftp mode=<normal|passive> - set the ftp mode of operation

Syntax show ftp- display the current ftp operation mode

FTP uses a set of separate ports for the data stream and command stream. This causes problems in security conscious companies who prefer that the client initiate the file transfer as well as the stream for the commands. To accommodate that, ftp added the capability called “passive ftp” in which the client initiating the connection initiates both the data and command connection request. Most companies prefer passive ftp and GarrettCom MNS-6K provides means to operate in those environments.

System Events

The Event Log records operating events as single-line entries listed in chronological order, and therefore can be a useful tool for isolating problems. Each Event Log entry is composed of four fields as shown below:

S Date Time Description -- S or Severity is one of the following:

I (Information) indicates routine events A (Activity) indicates the activity on Switch D (Debug). reserved for Magnum MNS-6K internal diagnostic information C (Critical) indicates that a severe Switch error has occurred F (Fatal). indicates that a service has behaved unexpectedly Date is the date in mm/dd/yy format (as per configured) that the entry was placed in the

log. Time is the time in hh:mm:ss format (as per configured) that the entry was placed in the

log. Description is a brief description of the event

The event log holds up to 1000 lines in chronological order, from the oldest to the newest. Each line consists of one complete event message. NOTE – since the event logs are written on the flash, once the flash memory is full, the logs stop writing. It is

Page 250 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 250 · click to enlarge
Page 250

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# show log S DATE TIME Log Description -- I 03-02-2005 5:14:43 P.M SYSMGR:System Subnet Mask changed I 01-01-2001 12:00:00 A.M SYSMGR:successfully registered with DB Manager I 01-01-2001 12:00:00 A.M SYSMGR:successfully read from DB A 01-01-2001 12:00:00 A.M VLAN:Vlan type set to Port VLAN I 01-01-2001 12:00:00 A.M SYSMGR:system was reset by user using CLI command I 01-01-2001 12:00:00 A.M SNTP:Date/Time set to 01-01-2001 12:00AM I 01-01-2001 12:00:00 A.M SNTP:Client started I 03-03-2005 4:32:48 A.M SNTP:Date and Time updated from SNTP server I 03-03-2005 9:31:59 A.M TELNET:Telnet Session Started I 03-03-2005 9:32:04 A.M CLI:manager console login A 03-03-2005 9:32:11 A.M IGMP:IGMP Snooping is enabled A 03-03-2005 9:35:40 A.M IGMP:IGMP Snooping is disabled A 03-03-2005 9:41:46 A.M IGMP:IGMP Snooping is enabled Magnum6K25# FIGURE 137 – Event log shown on the screen

Event logs can be exported to a ftp or a TFTP server on the network for further analysis or for other uses. To facilitate the export of the event log, the CLI command is exportlog as shown below

Syntax exportlog mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>]

[doctype=<raw|html>] – facilitates the export of the event log information as a text file or as an HTML file Where mode=<serial|tftp|ftp> - is the mode of transfer <ipaddress> - is the IP address of the ftp or TFTP server file=<name> - is the file name – please make sure the proper file extension is used e.g

html for an html file doctype=<raw|html> - indicates the log is saved as a text file (raw) or as an HTML file

Page 251 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 251 · click to enlarge
Page 251

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Magnum6K25# exportlog Usage exportlog mode= [] [file=] [doctype=] Magnum6K25# exportlog mode=tftp 192.168.5.2 file=eventlog doctype=html Do you wish to export the event logs? [ 'Y' or 'N'] Y Successfully uploaded the event log file. Magnum6K25# exportlog mode=tftp 192.168.5.2 file=eventlog.txt doctype=raw Do you wish to export the event logs? [ 'Y' or 'N'] Y Successfully uploaded the event log file. Magnum6K25# FIGURE 138 – Using exportlog to export the event log information

Intentionally left blank

Page 252 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 252 · click to enlarge
Page 252

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

For the alerts, the events per subsystem function are listed below. The table is sorted by the subsystem function first and then by the severity level.

Subsystem Description Severity BRIDGE Unable to delete MAC address from FDB D BRIDGE Unable to insert MAC address to FDB D BRIDGE Bridge init failed for ethx F BRIDGE Bridge enable for ethx failed F BRIDGE Bridge MIB init is done I CLI Manager login at console I CLI Operator login at console I CLI Manager password changed I CLI Operator password changed I DEVICE Port x enabled A DEVICE Port x disabled A DEVICE Port X link down A DEVICE Port X link up A DEVICE Ethernet counters init failure C DEVICE Unable to access ethernet counters C DEVICE Failed to read saved system logs D DEVICE Ethernet DMA init failure F DEVICE Ethernet hardware error F DEVICE Ethernet interrupt init failure F DEVICE Unable to allocate ethernet memory F DEVICE System started I DEVICE Network Stack not yet configured I DEVICE IP address a.b.c.d configured I DEVICE subnetmask a.b.c.d configured I DEVICE Default gateway a.b.c.d configured I DEVICE Switch rebooted by user I DEVICE No saved system logs I DEVICE Timezone set to x I DEVICE Country set to x (no DST) I DEVICE Country set to x (DST valid) I DEVICE Time set to x : y : z (HH:MM:SS) tz = a I DEVICE Date set to x : y : z (HH:MM:YYYY) I PRTMR Enabled by user monitor = x , sniffer = y I PRTMR Disabled by user I PS INTRUDER a:b:c:d:e:f @ port X , port disabled A PS INTRUDER a:b:c:d:e:f @ port X , port disabled A PS Port security enabled A PS port security disabled A PS Resetting MAC a:b:c:d:e:f at port X failed C PS Unable to delete learnt MACs in hardware D

Page 253 of the GarrettCom MNS-6K user manual — F
Page 253 · click to enlarge
Page 253

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Subsystem Description Severity RMON Alarm : internal error , unable to get memory F RMON Alarm : internal error, unable to get memory for alarm entry F

RMON Historyinternal error, unable to get memory for history control entry

F

RMON Historyinternal error, unable to get memory for history data entry

F

RMON History : internal error, unable to get memory F RMON Event : unable to get memory for event entry F RMON Alarm : unable to get memory for RMON logs F RMON rising alarm trap sent to a.b.c.d by alarm entry X I RMON falling alarm trap sent to a.b.c.d by alarm entry X I RMON RMON init is done I RMON history : control entry X is set to valid I RMON history : control entry X is set to invalid I RMON Event : entry X is set to valid I RMON Event : entry X is set to invalid I RMON Alarm : entry X is set to valid I RMON Alarm : entry X is set to invalid I SNMP Snmp.snmpEnableAuthenTraps is set to enabled A SNMP Snmp.snmpEnableAuthenTraps is set to disabled A SNMP System.sysName configured A SNMP System.sysLocation configured A SNMP System.sysContact configured A SNMP Port X link up trap sent to a.b.c.d A SNMP Port X Link down trap sent to a.b.c.d A SNMP Configuring IP address in trap receivers list failed D SNMP read community string changed I SNMP write community string changed I SNMP trap community string changed I SNMP authentication failure trap sent to a.b.c.d I SNMP Trap receiver a.b.c.d added I SNMP Trap receiver a.b.c.d deleted I SNMP Coldstart trap sent to a.b.c.d I SNMP Warmstart trap sent to a.b.c.d I SNTP client started I SNTP client stopped….disabled by user I SNTP client stopped….server not configured I SNTP Request timed out I SNTP Retrying.. I SNTP Time synchronized through SNTP I

Page 254 of the GarrettCom MNS-6K user manual — MAC Address Table
Page 254 · click to enlarge
Page 254

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Subsystem Description Severity TCP/IP Duplicate IP a.b.c.d sent from MAC address XXXXXX C

TCP/IP Unable to allocate memory for an ICMP packet C TCP/IP IP packet from a.b.c.d , with checksum error dropped D TCP/IP Bad IP fragments from a.b.c.d dropped D TCP/IP UDP checksum error in the received packet a.b.c.d D TCP/IP TCP checksum error in the received packet a.b.c.d D TCP/IP ICMP checksum error in the received packet D TCP/IP Failed to initialize the interface x F TCP/IP IP packet of version X is dropped I VLAN Type set to port I VLAN Type set to mac I VLAN Type set to tag I VLAN Type set to none I VLAN Pvlan: port based vlan started I VLAN Pvlan: default vlan is modified I VLAN Tvlan: Tag based vlan started I VLAN pvlan:vlan X enabled I VLAN pvlan:vlan X disabled I VLAN pvlan:vlan X deleted I VLAN pvlan:port based VLAN started I VLAN pvlan:port based VLAN stopped I VLAN pvlan:default vlan is modified I VLAN tvlan:vlan X deleted I VLAN tvlan:vlan X enabled I VLAN tvlan:vlan X disabled I VLAN tvlan:tag based VLAN stopped I VLAN tvlan:tag based VLAN started I FIGURE 139 – Listing of severity - sorted by subsystem and severity

Please refer to the related chapters in this manual to find more information. For example, for the VLAN subsystem, refer to the chapter on VLAN.

MAC Address Table

Syntax show address-table – displays the MAC addresses associated with ports – shows the MAC addresses on the ports and displays to which port the packet with the specified MAC addresses will be switched to

Page 255 of the GarrettCom MNS-6K user manual — List of commands in this chapter
Page 255 · click to enlarge
Page 255

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Sometimes it is useful to see which port a specific packet will be switched to by examining the internal MAC address table. The ‘show address-table’ command displays the internal switching table.

Magnum6K25# show address-table Sl# MAC Address Port 1 01:00:5e:00:00:fb 0 2 00:0c:f1:b9:d1:dc 3 3 33:33:00:00:00:02 0 4 01:00:0c:cc:cc:cc 0 5 01:00:5e:00:00:16 0 6 00:07:50:ef:31:40 3 7 00:e0:81:52:85:96 3 8 01:40:96:ff:ff:ff 0 9 01:40:96:ff:ff:00 0 10 00:40:96:33:51:81 3 Magnum6K25# FIGURE 140 – Display of the internal switching decision table

Where Sl# is the sequential listing form the memory and is just a sequence of the data as it appears in the memory. Port is the port number which the MAC address is assigned to. For example, if the packet with MAC address 00:0c:F1:B9:D1:DC (#2 above) appears with this MAC address in the DST field, the packet will be sent to port number 3. Also notice that there are other MAC addresses associated with port #3, indicating that the port has a hub or a switch connected to it.

List of commands in this chapter

Syntax alarm – enter the alarm configuration mode Syntax add event=<event-id|list|range|all> - enables alarm action in response to the specified event ID Syntax period time=<1..10> - sets the duration of relay action for the momentary type signal. This may be

needed to adjust to the behavior of the circuit or relay. Default is 3 seconds. Time is in seconds Syntax del event=<event-id|list|range|all> - disables alarm action in response to the specified event ID Syntax alarm <enable|disable> - globally enables or disables the alarm action Syntax show alarm - displays the current status of Alarm system Syntax smtp – configure the SNMP alerts to be sent via email

Page 256 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 256 · click to enlarge
Page 256

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax show smtp <config|recipients> - config – displays the current SMTP global settings and

recipients displays the currently configured recipients of email alerts Syntax add id=<1-5> email=<email-addr> [traps=<all|none|S|R|E>]

[events=<all|none|I|A|C|F|D>] [ip=<ip-addr>] [port=<1-65535>] id – [mandatory] the recipient ID - range from 1 to 5. MNS-6K allows a maximum of 5

recipients email – [mandatory] email address of the recipient traps – [optional] this is the trap filter. If value is “all”, all traps of any type will be sent to

this recipient. If value is none, no traps are sent to this recipient. Value can also be a combination of ‘S’ (SNMP), ‘R’ (RMON) and ‘E’ (ENTERPRISE). For example, trap=SR means that SNMP and RMON traps will be sent via email to the recipient. If this option is not defined, the recipient will have a default value of “all” events – [optional] this is the event filter. Value can be “all” - all event severity types will

be sent to recipient, “none” - no event will be sent to recipient or a combination of ‘I’ (informational), ‘A’ (activity), ‘C’ (critical), ‘F’ (fatal) and ‘D’ (debug). With “event=ACF” implies that events of severity types activity, critical and fatal will be sent to recipients by email. If this option is not defined, a value of “all” is taken ip – [optional] SMTP server IP address. This is the SMTP server to connect to for this

particular user. If this option is not defined, the global/default SMTP server is used port – [optional] TCP port of the SMTP server. If this is not defined, the global default

TCP port is used Syntax delete id=<1-5> - delete the specific id specified. The deleted id no longer receives the traps via email.

The id is added using the “add” command Syntax sendmail server=<ip-addr> to=<email-addr> from=<email-addr>

subject=<string> body=<string> - customize (and also to send a test email to check SMTP settings) the email sent out by specifying the email subject field, server address, to field and the body of the text. See example fo the body of the text message later in this chapter server – [mandatory] SMTP server IP v4 address. to – [mandatory] the recipient email address from – [mandatory] the sender email address. subject – [mandatory] email subject or title

Page 257 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 257 · click to enlarge
Page 257

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

body – [mandatory] email body Syntax server ip=<ip-addr> [port=<1-65535>] [retry=<0-3>] – configure the global SMTP server

settings ip – [mandatory] SMTP server IP address port – [mandatory] TCP port to be used for SMTP communications – default is 25 retry – [optional] specifies how many times to retry if an error occurs when sending email.

Range from 0 to 3. Default is 0. Syntax smtp <enable|disable> - enables or disables SMTP to send SNMP alerts by email Syntax exportlog mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>]

[doctype=<raw|html>] – facilitates the export of the event log information as a text file or as an HTML file Syntax !! – repeat the last command Syntax !<n> - repeat the “n”th command (as indicated by a show history) Syntax show history – show the last 25 commands executed – if less than 25 commands are executed, only

those commands executed are shown Syntax <Up-arrow> - every time the key is pressed, the last command is printed on the screen but not executed.

This allows for editing errors made in typing Syntax <Down-arrow> - opposite of Up-arrow key Syntax show version – displays the version of MNS-6K being used Syntax set ftp mode=<normal|passive> - set the ftp mode of operation

Syntax show ftp- display the current ftp operation mode

Syntax ping <ipaddress> [count=<1-999>] [timeout=<1-256>] – use the ping command to test

connectivity Syntax set prompt <prompt string> - set the prompt for switch. The prompt has predefined

variables. These are $n : System Name; $c : System Contact; $l : System Location; $i : System IP; $m : System MAC; $v : Version; $$ : $ Character; $r : New Line; $b : Space

Page 258 of the GarrettCom MNS-6K user manual — Chapter 2 – Getting Started
Page 258 · click to enlarge
Page 258

APPENDIX

APPENDIX 1 - Command listing by Chapter

A rich environment – this Appendix provides a reference to the commands by chapter

Chapter 2 – Getting Started

Syntax ipconfig [ip=<ip-address>] [mask=<subnet-mask>] [dgw=<gateway>] – to set IP

address on the switch Syntax save – save changes made to the configuration Syntax reboot – restart the switch – same effect as physically turning off the power Syntax show setup – show setup parameters Syntax show config – show setup parameters configured Syntax enable <user-name> - changing the privilege level Syntax add user=<name> level=<number> - adding a user Syntax delete user=<name> - deleting a user Syntax passwd user=<name> - changing a password for a user Syntax chlevel user=<name> level=<number> - changing the user privilege level Syntax useraccess user=<name> service=<telnet|web> <enable|disable> Syntax help <command string> - help for a specific command

Page 259 of the GarrettCom MNS-6K user manual — Chapter 3 – IP Address and System Information
Page 259 · click to enlarge
Page 259

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax command <Enter> - options for a command Syntax <TAB> - listing all commands available at the privilege level Syntax <command string> <TAB> - options for a command Syntax <first character of the command> <TAB> - listing commands starting with the character Syntax logout – logout from the CLI session

Chapter 3 – IP Address and System Information

Syntax set bootmode type=<dhcp|bootp|manual|auto> [bootimg=<enable|disable>] [bootcfg=[<enable|disable>] – assign the boot mode for the switch

Where <dhcp|bootp|manual|auto> - where

dhcp – look only for DHCP servers on the network for the IP address. Disable

bootp or other modes bootp – look only for bootp servers on the network. Disable dhcp or other mode manual – do not set the IP address automatically auto - the switch will first look for a DHCP server. If a DHCP server is not found,

it will then look for a BootP server. If that server is not found, the switch will check to see if the switch had a pre-configured IP address. If it did, the switch would be assigned that IP address. If the switch did not have a pre-configured IP address, it would inspect if the IP address 192.168.1.2 with a netmask of 255.255.255.0 is free. If the IP address is free, MNS-6K will assign the switch that IP address. If the address is not free, MNS-6K will poll the network for DHCP server then BootP server then check if the IP address 192.68.1.2 is freed up bootimg=<enable|disable> - valid with type=bootp only. This option allows the

switch to load the image file from the BootP server. This is useful when a new switch is put on a network and the IT policies are set to load only a specific MNS-6Kimage which is supported and tested by IT personnel. bootcfg=<enable|disable> - valid with type=bootp only. This option allows the switch

to load the configuration file from the BootP server. This is useful when a new switch is put on a network and the specific configurations are loaded from a centralized BootP server Syntax telnet <enable|disable> - enables or disables telnet sessions Syntax telnet <ipaddress> [port=<port number>] – telnet from the switch

Page 260 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 260 · click to enlarge
Page 260

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax set serial [baud=<rate>] [data=<5|6|7|8>] [parity=<none|odd|even>]

[stop=<1|1.5|2>] [flowctrl=<none|xonxoff>] – sets serial port parameters Syntax snmp – enter the snmp configuration mode Syntax setvar [sysname|syscontact|syslocation]=<string> - sets the system name, contact and

location information Syntax set timezone GMT=[+ or -] hour=<0-14> min=<0-59> - sets the timezone Syntax set date year=<2001-2035> month=<1-12> day=<1-31>

[format=<mmddyyyy|ddmmyyyy|yyyymmdd>] – sets the date and the format in which the date is displayed Syntax set time hour=<0-23> min=<0-59> sec=<0-59> [zone=GMT[+/-]hh:mm] – sets the

time (as well as the timezone) Syntax set timeformat format=<12|24> - sets the display time in the 12/24 hour mode Syntax set daylight country=< country name> - sets the daylight saving time Syntax setsntp server = <ipaddress> timeout = <1-10> retry = <1-3> - setup the SNTP server Syntax sync [hour=<0-24>] [min=<0-59>] – setup the frequency at which the SNTP server is queried Syntax sntp [enable|disable] – enables or disables the SNTP services Syntax saveconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>] – saves the

configuration on the network using tftp, ftp or serial protocols Syntax loadconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>] – loads the previously

saved configuration from the network using tftp, ftp or serial protocols Syntax kill config [save=module_name] – resets the system configuration. The module_name option does not

reset the specific module parameters. The modules are system, event, port, bridge, stp, ps, mirror, sntp, vlan, gvrp and snmp Syntax show session – display telnet sessions active on the switch

Syntax kill session id=<session> - kill a specific telnet session

Syntax set ftp mode=<normal|passive> - set the ftp mode of operation

Syntax show ftp- display the current ftp operation mode

Page 261 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 261 · click to enlarge
Page 261

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax ftp <get|put|list|del> [type=<app|config|oldconf|script|hosts|log>]

[host=<hostname>] [ip=<ipaddress>] [file=<filename>] [user=<user>] [pass=<password>] – upload and download information using ftp command Where <get|put|list|del> - different ftp operations [type=<app|config|oldconf|script|hosts|log>] – optional type field. This is useful

to specify whether a log file or host file is uploaded or downloaded. This can also perform the task of exporting a configuration file or uploading a new image to the switch [host=<hostname>] [ip=<ipaddress>] [file=<filename>] [user=<user>] [pass=<password>] – parameters associated with ftp server for proper communications with the server Syntax tftp <get|put> [type=<app|config|oldconf|script|hosts|log>]

[host=<hostname>] [ip=<ipaddress>] [file=<filename>] – upload and download information using tftp command Where <get|put> - different tftp operations – get a file from the server or put the information

on the server [type=<app|config|oldconf|script|hosts|log>] – optional type field. This is useful

to specify whether a log file or host file is uploaded or downloaded. This can also perform the task of exporting a configuration file or uploading a new image to the switch [host=<hostname>] [ip=<ipaddress>] [file=<filename>] – parameters associated

with tftp server for proper communications with the server Syntax xmodem <get|put> [type=<app|config|oldconf|script|hosts|log>] – upload and

download information using xmodem command and console connection

Where <get|put> - different xmodem file transfer operations – get a file from the server or put

the information on the server [type=<app|config|oldconf|script|hosts|log>] – optional type field. This is useful

to specify whether a log file or host file is uploaded or downloaded. This can also perform the task of exporting a configuration file or uploading a new image to the switch Syntax host <add|edit|del> name=<host-name> [ip=<ipaddress>] [user=<user>]

[pass=<password>] – create a host entry for accessing host. This is equivalent to creating a host table on many systems. Maximum of 10 such entries are allowed Syntax show host – displays the host table entries

Page 262 of the GarrettCom MNS-6K user manual — Chapter 4 – IPv6
Page 262 · click to enlarge
Page 262

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax climode <script|console|show> - set the interactive CLI mode on (console) or off

(script). To see the mode – use the show option Syntax more <enable|disable|show> - enable or disable the scrolling of lines one page at a

time Syntax configure access – sets the access parameters (e.g. disable telnet session) Syntax show ipconfig – shows IP parameters set Syntax show console – reviews console settings Syntax show serial – reviews serial settings Syntax show setup – reviews system parameters Syntax show sysconfig – reviews settable system parameters Syntax show time – shows the system time Syntax show timezone – shows the system timezone Syntax show date – shows the system date Syntax show uptime – shows the amount of time the switch has been operational Syntax show config [module=<module-name>] – displays the configuration Syntax show setup – display the setup, serial number, factory code information and more

Chapter 4 – IPv6

Syntax ipconfig [ip=<ip-address>] [mask=<subnet-mask>] [dgw=<gateway>]

[add|del] – configure and IPv6 address. The add/delete option can be used to add or delete IPv4/IPv6 addresses Syntax show ipconfig – display the IP configuration information – including IPv6 address Syntax ping6 <IPv6 address> - pings an IPv6 station Syntax show ipv6 - displays the IPv6 information Syntax ftp <IPv6 address> - ftp to an IPv6 station

Page 263 of the GarrettCom MNS-6K user manual — Chapter 5 – Access Considerations
Page 263 · click to enlarge
Page 263

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax telnet <IPv6 address> - telnet to an IPv6 station

Chapter 5 – Access Considerations

Syntax set password – set or change password Syntax configure port-security – sets the port authorization based on MAC addresses Syntax port-security – configure port security settings Syntax allow mac=<address|list|range> port=<num|list|range> - specify a specific MAC

address or MAC address list Syntax learn port=<number-list> <enable|disable> - learn MAC addresses connected to the

Magnum 6K switch Syntax show port-security – display port security settings Syntax action port=<num|list|range> <none|disable|drop> - action to perform in case of breach

of port security Syntax signal port=<num|list|range> <none|log|trap|logandtrap> - port to monitor and

signal to send in case of breach of port security Syntax ps <enable|disable> - enable or disable port security Syntax remove mac=<all|address|list|range> port=<num|list|range> - remove a MAC

address entry Syntax show log [fatal|alert|crit|error|warn|note|info|debug] – display logs and specific types

of logs Syntax clear log [fatal|alert|crit|error|warn|note|info|debug] – clear logs or specific type of

logs Syntax set logsize size=<1-1000> - set the log buffer size Syntax access – setup access configuration parameters

Page 264 of the GarrettCom MNS-6K user manual — Chapter 6 – Access Using Radius
Page 264 · click to enlarge
Page 264

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax allow ip=<ipaddress> mask=<netmask> service=<name|list> - allow specific IP

address or range of addresses as a trusted host(s) Syntax deny ip=<ipaddress> mask=<netmask> service=<name|list> - deny specific IP

address or range of IP addresses Syntax remove ip=<ipaddress> mask=<netmask> - delete a specific IP address from the access or

trusted host list Syntax removeall – remove all IP addresses of trusted hosts Syntax show ip-access – display all trusted hosts Syntax clear <history|log [1..5 |informational |activity |critical |fatal |debug] |terminal

|arp|portstats|addr] – clear command to clear various aspects of the MNS-6K information – most notably “clear addr” – clears the addresses learnt or “clear log” to clear the logs (and the type of logs)

Chapter 6 – Access Using Radius

Syntax auth configuration mode to configure the 802.1x parameters Syntax show auth <config|ports> show the 802.1x configuration or port status Syntax authserver [ip=<ip-addr>] [udp=<num>] [secret=<string>] define the RADIUS server

– use UDP socket number if the RADIUS authentication is on port other than 1812 Syntax auth <enable|disable> enables or disables the 802.1x authenticator function on MNS-6K switch Syntax setport port=<num|list|range> [status=<enable|disable>]

[control=<auto|forceauth|forceunauth>] [initialize=<assert|deassert>] setting the port characteristic for an 802.1x network Syntax backend port=<num|list|range> supptimeout=<1-240>] [servertimeout=<1-240>]

[maxreq=<1-10>] configure parameters for EAP over RADIUS

port – [mandatory] – port(s) to be configured supptimeout – [optional] This is the timeout in seconds the authenticator waits for the supplicant to respond back. Default value is 30 seconds. Values can range from 1 to 240 seconds. servertimeout – [optional] This is the timeout in seconds the authenticator waits for the backend RADIUS server to respond back. The default value is 30 seconds. Values can range from 1 to 240 seconds.

Page 265 of the GarrettCom MNS-6K user manual — Chapter 7 – Access using TACACS+
Page 265 · click to enlarge
Page 265

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

maxreq – [optional] The maximum number of times the authenticator will retransmit an EAP Request packet to the Supplicant before it times out the authentication session. Its default value is 2. It can be set to any integer value from 1 to 10. Syntax portaccess port=<num|list|range> [quiet=<0-65535>] [maxreauth=<0-10>]

[transmit=<1-65535>] set port access parameters for authenticating PCs or supplicants

port – [mandatory] – ports to be configured quiet – [optional] This is the quiet period, the amount of time, in seconds, the supplicant is held after an authentication failure before the authenticator retries the supplicant for connection. The default value is 60 seconds. Values can range from 0 to 65535 seconds. maxreauth – [optional] The number of re-authentication attempts that are permitted before the port becomes unauthorized. Default value is 2. Values are integers and can range from 0 to 10. transmit – [optional] This is the transmit period, this is the time in seconds the authenticator waits to transmit another request for identification from the supplicant. Default value is 30. Values can be from 1 to 65535 seconds Syntax reauth port=<num|list|range> [status=<enable|disable>] [period=<10-86400>]

set values on how the authenticator (Magnum 6K switch) does the re-authentication with the supplicant or PC

port – [mandatory] – ports to be configured status – [optional] This enables/disables re-authentication period – [optional] this is the re-authentication period in seconds. This is the time the authenticator waits before a re-authentication process will be done again to the supplicant. Default value is 3600 seconds (1 hour). Values can range from 10 to 86400 seconds. Syntax show-stats port=<num> displays 802.1x related statistics Syntax trigger-reauth port=<num|list|range> manually initiate a re-authentication of supplicant

Chapter 7 – Access using TACACS+

Syntax show tacplus <status|servers> - show status of TACACS or servers configured as TACACS+

servers Syntax tacplus <enable|disable> [ order=<tac,local | local,tac>] - enable or disable TACACS

authentication, specifying the order in which the server or local database is looked up where “tac,local” implies, first the TACAS+ server, then local logins on the device

Page 266 of the GarrettCom MNS-6K user manual — Chapter 8 – Port mirroring and setup
Page 266 · click to enlarge
Page 266

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax tacserver <add|delete> id=<num> [ip=<ip-addr>] [port=<tcp-port>]

[encrypt=<enable|disable>] [key=<string>] [mgrlevel=<level>] [oprlevel=<level>] – adds a list of up to five TACACS+ servers where <add|delete> – [mandatory] adds or delete a TACACS+ server. id=<num> – [mandatory] the order in which the TACACS+ servers should be polled for authenticaton [ip=<ip-addr>] – [mandatory for add] the IP address of the TACACS+ server [port=<tcp-port>] – [optional for add] TCP port number on which the server is listening [encrypt=<enable|disable>] – [optional for add] enable or disable packet encryption [key=<string>] – [optional for add, mandatory with encrypt] when encryption is enabled, the secret shared key string must be supplied [mgrlevel=<level>] and [oprlevel=<level>] – [optional] specifies the manager and operator level as defined on the TACACS+ server for the respective level of login

Chapter 8 – Port mirroring and setup

Syntax show port-mirror – display port mirror settings Syntax port-mirror <enter> - configure port mirror settings Syntax setport monitor=<monitor port number> sniffer=<sniffer port number> - set port

mirror settings Syntax prtmr <enable|disable> - enable or disable port mirror settings Syntax device – configure device and port specific settings Syntax setport port=<port#|list|range> [name=<name>] [speed=<10|100>]

[duplex=<half|full>] [auto=<enable|disable>] [flow=<enable|disable>] [bp=<enable|disable>] [status=<enable|disable>] – configure port settings Syntax show port[=<Port number>] – display port settings Syntax flowcontrol xonlimit=<value> xofflimit=<value> - configure flow control buffers Syntax show flowcontrol – display flow control buffers Syntax backpressure rxthreshold=<value> - configure backpressure buffers Syntax show backpressure – display backpressure buffers

Page 267 of the GarrettCom MNS-6K user manual — Chapter 9 - VLAN
Page 267 · click to enlarge
Page 267

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax broadcast-protect <enable|disable> - protect switch from broadcast storms Syntax rate-threshold port=<port|list|range> rate=<frames/sec> - change the allowed broadcast

Chapter 9 - VLAN

Syntax set vlan type=<port|tag|none> defines the VLAN type Syntax configure vlan type=port enter the VLAN configuration commands Syntax vlan type=port enter the VLAN configuration commands Syntax add id=<vlan Id> [name=<vlan name>] port=<number|list|range>

[forbid=<number|list|range>] [<mgt|nomgt>] - adding VLAN Syntax edit id=<vlan id> [name=<vlan name>] port=<number|list|range>

[<mgt|nomgt>] - edit existing VLAN name Syntax start vlan=<name|number|list|range> activate the VLAN configuration Syntax save save the configuration (including the VLAN configuration) Syntax show vlan type=<port|tag> [<id=vlanid>] display specific VLAN information Syntax set-port port=<number|list|range> default id=<number> sets the default VLAN id.

For Magnum 6K family of switches, the default VLAN id is 1, unless changed using this command Syntax set-port port=<number|list|range> filter status=<enable|disable> enables or disables

the VLAN filtering function. Syntax set-port port=<number|list|range> tagging id=<number> status=<tagged|

untagged> defines whether the outgoing packets from a port will be tagged or untagged. Syntax set-port port=<number|list|range> join id=<number> adds the specified port(s) to the

specified VLAN id Syntax set-port port=<number|list|range> leave id=<number> releases a specific port from a

VLAN Syntax show-port [port=<port|list|range>] shows all parameters related to tag vlan for the list of ports.

If the port parameter is omitted, it will display all ports

rate threshold

Page 268 of the GarrettCom MNS-6K user manual — Chapter 11 – Rapid Spanning Tree Protocol
Page 268 · click to enlarge
Page 268

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Chapter 10 – Spanning Tree Protocol (STP)

Syntax show stp <config|ports > - regardless of whether STP is enabled or disabled (default) this

command lists the switch’s full STP configuration, including general settings and port settings Syntax stp – STP Configuration mode Syntax stp <enable|disable> - Start (Enable) or stop (Disable) STP Syntax priority [port=<number|list|range>] value=<0-255 | 0-65535> - specifies the port or

switch level priority. When a port(s) are specified the priority is associated with ports and their value is 0- 255. If no ports are specified, then the switch (bridge) priority is specified and its value is 0-65535 Syntax cost port=<number|list|range> value=<0-65535> - cost is specific to a port and the port(s)

have to be specified Syntax port port=<number|list|range> status=<enable|disable> - specific ports may not need to

participate in STP process. These ports typically would be end-stations. If you are not sure – let MNS-6K software make the decisions

Syntax timers forward-delay=<4-30> hello=<1-10> age=<6-40> - change the STP Forward

Delay, Hello timer and Aging timer values

Chapter 11 – Rapid Spanning Tree Protocol

Syntax set stp type=<stp|rstp> - Set the switch to support RSTP or change it back to STP. Need to save

and reboot the switch after this command Syntax rstp – enter the RSTP configuration mode Syntax rstp <enable|disable> - enable RSTP – by default, this is disabled and has to be manually

activated Syntax port port=<number|list|range> [status=<enable|disable>]

[migration=<enable>] [edge=<enable|disable>] [p2p=<on|off|auto>] - set the port type for RSTP

Page 269 of the GarrettCom MNS-6K user manual — Chapter 12 – RS-Ring, S-Ring and Link-Loss-Learn
Page 269 · click to enlarge
Page 269

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Example port port=<number|list|range> p2p= off - Set the “point-to-point” value to off on

all ports that are connected to shared LAN segments (i.e. connections to hubs). The default value is auto. P2P ports would typically be end stations or computers on the network Example port port=<number|list|range> edge=enable – enable all ports connected to

other hubs, bridges and switches as edge ports Example port port=<number|list|range> migration=enable – set this for all ports

connected to other devices such as hubs, bridges and switches known to support IEEE 802.1d STP services, but cannot support RSTP services Syntax show active-stp – status whether STP or RSTP is running Syntax show stp <config|ports> - display the RSTP or STP parameters

Syntax forceversion <stp|rstp> - set the STP or RSTP compatibility mode Syntax show-forceversion - the current forced version Syntax show-timers - show the values of the timers set for RSTP Syntax priority [port=<number|list|range>] value=<0-255 | 0-65535> - specifies the port or

switch level priority. When a port(s) are specified the priority is associated with ports and their value is 0- 255. If no ports are specified, then the switch (bridge) priority is specified and its value is 0-65535 Syntax cost port=<number|list|range> value=<0-65535> - cost is specific to a port and the port(s)

have to be specified Syntax port port=<number|list|range> status=<enable|disable> - specific ports may not need to

participate in STP process. These ports typically would be end-stations. If you are not sure – let MNS-6K software make the decisions

Syntax timers forward-delay=<4-30> hello=<1-10> age=<6-40> - change the STP Forward delay,

Hello timer and Aging timer values

Chapter 12 – RS-Ring, S-Ring and Link-Loss-Learn

Syntax authorize <module> key=<security key> - activate the S-Ring capabilities. Don’t forget to use

the “save” command to save the key Syntax stp – STP Configuration mode Syntax stp <enable|disable> - Start (Enable) or stop (Disable) STP

Page 270 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 270 · click to enlarge
Page 270

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax set stp type=<stp|rstp> - set the spanning tree protocol to be IEEE 802.1d or 802.1w (Spanning

Tree Protocol or Rapid Spanning Tree Protocol) Syntax show active-stp – Display which version of STP is currently active Syntax show s-ring – show the status of S-ring status and configuration Syntax s-ring <enable|disable> - enable or disable S-ring capabilities Syntax s-ring learn – start the learning process to discover the ring and the ports which make up the S-ring Syntax s-ring add port=<port1,port2> - define ports which make up the S-ring ports. Note as discussed earlier, you can create multiple s-rings on a switch Syntax s-ring del port=<port1,port2> - remove the switch from S-ring topology by eliminating the end ports on the switch Syntax lll <enable|disable> - enable or disable LLL on the switch Syntax lll add port=<port|list|range> - enable LLL on the list of specified ports Syntax lll del port=<port|list|range> - disable LLL on the list of specified ports Syntax show lll – display the status of LLL Syntax rstp – STP Configuration mode Syntax rstp <enable|disable> - Start (Enable) or stop (Disable) STP Syntax set stp type=<stp|rstp> - set the spanning tree protocol to be IEEE 802.1d or 802.1w (Rapid

Spanning Tree Protocol) Syntax show active-stp – Display which version of STP is currently active Syntax show rs-ring – show the status of RS-ring status and configuration Syntax rs-ring <enable| disable> - enable or disable RS-ring capabilities Syntax rs-ring add port=<port1,port2> - define ports which make up the RS-ring ports. Note as

discussed earlier, you can create multiple RS-rings on a switch Syntax rs-ring del port=<port1,port2> - remove the switch from RS-ring topology by eliminating the end

ports on the switch

Page 271 of the GarrettCom MNS-6K user manual — Chapter 15 – Quality of Service
Page 271 · click to enlarge
Page 271

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Chapter 13 – Dual-Homing

Syntax dualhome – enter the dual-homing configuration sub-system Syntax dualhome <enable|disable> – enable or disable dual-homing Syntax dualhome add port1=<port#> port2=<port#> – dual-homing setup similar to that of unmanaged switches such as ESD42 OR Syntax dualhome add primary=<port#> secondary=<port#> – dual-homing setup as primary- secondary mode Syntax dualhome del – Delete the dual-homing setup Syntax show dualhome – Display dual-homing status

Chapter 14 – Link Aggregation Control Protocol (LACP)

Syntax lacp - enable the LACP configuration module within CLI Syntax lacp <enable | disable> - enable or disable LACP Syntax add port=<number|list|range> [priority=<0-65535>] – add the specified list of ports to

form the logical LACP trunk. Default value for priority is 32768. The lower the value assigned to priority, the higher the priority. The port with the highest priority is the primary port (over which certain types of traffic like IGMP is transmitted) Syntax del port=<number|list|range> - delete specified ports from the LACP membership Syntax edit port=<number|list|range> [priority=<priority>] - edit the membership of the ports

specified. The priority can be from 0 – 65535 Syntax show lacp – displays the status and other relevant LACP information

Chapter 15 – Quality of Service

Syntax qos – enter the QoS configuration mode

Page 272 of the GarrettCom MNS-6K user manual — Chapter 16 - IGMP
Page 272 · click to enlarge
Page 272

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax setqos type=<port|tag|tos|none> port=<port|list|range> [priority=<high|low>]

[tos=<0-63|list|range>][tag=<0-7|list|range>] - depending on the type of QOS, the corresponding field has to be set. For example, for QOS type tag, the tag levels have to be set, and for QOS type ToS, the ToS levels have to be set. If the priority field is not set, it then defaults to low priority. ToS has 64 levels and the valid values are 0-63 and a tagged packet has 8 levels and the valid values are 0-7. Syntax set-weight weight=<0-7> - sets the port priority weight for All the ports. Once the weight is set, all

the ports will be the same weight across the switch. The valid value for weight is 0-7 Syntax show-portweight - display the weight settings on a port Syntax show qos [type=<port|tag|tos>] [port=<port|list|range>] – displays the QoS settings Syntax set-untag port=<port|list|range> priority=<high|low> tag=<0-7> - The 802.1p user

priority assigned to untagged received packets to be transmitted as tagged from the priority queue

Chapter 16 - IGMP

Syntax igmp – IGMP configuration mode Syntax igmp <enable/disable> - enable or disable IGMP on the switch Syntax show igmp – IGMP operation status Syntax mcast <enable | disable> - enable or disable unknown multicast streams. The default is enabled Syntax set igmp mode= <normal|l2> - set the IGMP mode. Normal is when a L3 device is in the network and is the IGMP root. The IGMP-L2 is used when there is no L3 device in the network Syntax show-group – shows the multicast groups Syntax set-port port=< port|list|range> mode=<auto|forward|block> - set the port

characteristics. Block drops the unregistered multicasts. Forward forwards unregistered multicasts Syntax show-port – display the port characteristics for IGMP Syntax show-router – displays detected IGMP-enabled router ports Syntax set-leave <enable|disable> - enables or disables the switch to immediately process a host sending a

leave message rather that wait for the timer to expire Syntax set-querier <enable|disable> - enables or disables a switch as IGMP querier

Page 273 of the GarrettCom MNS-6K user manual — Chapter 18 – SNMP
Page 273 · click to enlarge
Page 273

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax set-qi interval=<value> - The IGMP querier router periodically sends general host-query messages.

These messages are sent to ask for group membership information. This is sent to the all-system multicast group address, 224.0.0.1. The default value is 125 seconds. The valid range can be from 60 to 127 seconds. Syntax set-qri interval=<value> - The query response interval is the maximum amount of time that can

elapse between when the querier router sends a host-query message and when it receives a response from a host. The Default value is 10 seconds. The Range can be from 2 to 270 seconds. Restrictions apply to the maximum value because of an internal calculation that is dependent on the value of the Query Interval Syntax mode=<l2|normal> - Toggle the IGMP mode from L2 to nnormal or IGMP-L2

Chapter 17 - GVRP

Syntax show gvrp - shows whether GVRP is disabled, along with the current settings for the maximum

number of VLANs and the current Primary VLAN Syntax gvrp <enable|disable> - enable or disable GVRP Syntax show-vlan – list all the VLANs (including dynamic VLANs) on the switch Syntax set-ports port=<port|list|range> state=<learn|block|disable> - set the state of the port to learn, block or disable for GVRP. Note the default state is disable Syntax static vlan=<VID> - convert a dynamic VLAN to a static VLAN Syntax set-forbid vlan=<tag vlanid> forbid=<port-number|list|range> - sets the forbid GVRP capability on the ports specified Syntax show-forbid – display the ports with GVRP forbid capabilities

Chapter 18 – SNMP

Syntax snmp – enter the SNMP Configuration mode Syntax snmpv3 – enter the SNMP V3 configuration mode – note enable SNMP V3 by using the “set

snmp” command which follows Syntax set snmp type=<v1|all> - define the version of SNMP to use – the option all supports all versions

(v1, v2 and v3) – v1 restricts SNMP to v1 only. By default – SNMP v1only is enabled Syntax show active-snmp – shows the version of SNMP currently in use

Page 274 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 274 · click to enlarge
Page 274

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax community [write=<write community>] [read=<read community>] [trap=<trap

community>] – set the necessary community strings Syntax authtraps <enable|disable> - enables or disables authentication traps generation Syntax traps <add|delete> type=<Snmp|Rmon|Snmp,Rmon|Enterprise|

Snmp,Enterprise |Rmon,Enterprise|All> ip=<ipaddress> - add v1 traps as well as define the trap receiver Syntax show snmp – displays the SNMP configuration information Syntax mgrip <add|delete> ip=<IPaddress> - adds or deletes a management station, specified by the

IP address, which can query SNMP variables from the switch. This is done to protect the switch from being polled by unauthorized managers. Maximum of five stations allowed. Syntax setvar [sysname|syscontact|syslocation]=<string> sets the system name, contact and

location. All parameters are optional but a user must supply at least one parameter Syntax quickcfg - quick setup for snmpv3 configuration. It automatically configures a default VACM (view-

based access control model). This allows any manager station to access the Magnum 6K switch either via SNMP v1, v2c or v3. The community name is “public”. This command is only intended for first time users and values can be changed by administrators who want more strict access Syntax engineid string=<string> - Every agent has to have an engineID (name) to be able to respond to

SNMPv3 messages. The default engine ID value is “6K_v3Engine”. This command allows the user to change the engine ID Syntax authtrap <enable|disable> - enables or disables authentication traps generation Syntax show-authtrap - displays the current value of authentication trap status. Syntax deftrap community= - defines the default community string to be used when sending traps.

When user does not specify the trap community name when setting a trap station using the “trap” command, the default trap community name is used Syntax show-deftrap - displays the current value of default trap Syntax trap <add|delete> id=<id> [type=<v1|v2|inform>] [host=<host-ip>]

[community=<string>] [port=<1-65534>] - define the trap and inform manager stations. The station can receive v1, v2 traps and/or inform notifications. An inform notification is an acknowledgments that a trap has been received. A user can add up to 5 stations. Syntax show-trap [id=<id#>]- shows the configured trap stations in tabular format - id is optional and is

the number corresponding to the trap entry number in the table

Page 275 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 275 · click to enlarge
Page 275

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax com2sec <add|delete> id=<id> [secname=<name>] [source=<source>] [community=<community>] - a part of the View based Access control model (VACM) as defined

in RFC 2275. This specifies the mapping from a source/community pair to a security name. On MNS- 6K, up to 10 entries can be specified Syntax group <add|delete> id=<id> [groupname=<name>] [model=<v1|v2c|usm>] [com2secid=<com2sec-id>] - a part of the View based Access

control model (VACM) as defined in RFC 2275. This command defines the mapping from sec model or a sec name to a group. A sec model is one of v1, v2c, or usm. On MNS-6K, up to 10 entries can be specified Syntax show-group [id=<id>] - display all or specific group entries - id is optional and is the number

corresponding to the group entry number in the table Syntax view <add|delete> id=<id> [viewname=<name>] [type=<included|excluded>]

[subtree=<oid>] [mask=<hex-string>] - a part of the View based Access control model (VACM) as defined in RFC 2275. This command defines a manager or group or manager stations what it can access inside the MIB object tree. On MNS-6K, up to 10 entries can be specified Syntax show-view [id=<id>] - display all or specific view entries - id is optional and is the number

corresponding to the view entry number in the table Syntax user <add|delete> id=<id> [username=<name>] [usertype=<readonly|readwrite>] [authpass=<pass-phrase>] [privpass=<pass-phrase>] [level=<noauth|auth|priv>] [subtree=<oid>] for

quickly adding or deleting v3 USM based security, this command adds user entries. MNS-6K allows up to 5 users to be added. Right now, the MNS-6K agent only support noauth and auth-md5 for v3 authentication and auth-des for priv authentication Syntax show-user [id=<id>] - display all or specific view entries - id is optional and is the number

corresponding to the view entry number in the table Syntax rmon – enter the RMON configuration mode to setup RMON groups and communities Syntax history def-owner=<string> def-comm=<string> - define the RMON history group and the

community string associated with the group Syntax statistics def-owner=<string> def-comm=<string>- define the RMON statistics group and

the community string associated with the group Syntax alarm def-owner=<string> def-comm=<string> - define the RMON alarm group and the

community string associated with the group Syntax event def-owner=<string> def-comm=<string> - define the RMON event group and the

community string associated with the group

Page 276 of the GarrettCom MNS-6K user manual — Chapter 19 – Miscellaneous Commands
Page 276 · click to enlarge
Page 276

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax show rmon <stats|hist|event|alarm> - list the specific RMON data as defined by the group

Chapter 19 – Miscellaneous Commands

Syntax alarm – enter the alarm configuration mode Syntax add event=<event-id|list|range|all> - enables alarm action in response to the specified event ID Syntax period time=<1..10> - sets the duration of relay action for the momentary type signal. This may be

needed to adjust to the behavior of the circuit or relay. Default is 3 seconds. Time is in seconds Syntax del event=<event-id|list|range|all> - disables alarm action in response to the specified event ID Syntax alarm <enable|disable> - globally enables or disables the alarm action Syntax show alarm - displays the current status of Alarm system Syntax smtp – configure the SNMP alerts to be sent via email Syntax show smtp <config|recipients> - config – displays the current SMTP global settings and

recipients displays the currently configured recipients of email alerts Syntax add id=<1-5> email=<email-addr> [traps=<all|none|S|R|E>]

[events=<all|none|I|A|C|F|D>] [ip=<ip-addr>] [port=<1-65535>] id – [mandatory] the recipient ID - range from 1 to 5. MNS-6K allows a maximum of 5

recipients email – [mandatory] email address of the recipient traps – [optional] this is the trap filter. If value is “all”, all traps of any type will be sent to

this recipient. If value is none, no traps are sent to this recipient. Value can also be a combination of ‘S’ (SNMP), ‘R’ (RMON) and ‘E’ (ENTERPRISE). For example, trap=SR means that SNMP and RMON traps will be sent via email to the recipient. If this option is not defined, the recipient will have a default value of “all” events – [optional] this is the event filter. Value can be “all” - all event severity types will

be sent to recipient, “none” - no event will be sent to recipient or a combination of ‘I’ (informational), ‘A’ (activity), ‘C’ (critical), ‘F’ (fatal) and ‘D’ (debug). With

type

Page 277 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 277 · click to enlarge
Page 277

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

“event=ACF” implies that events of severity types activity, critical and fatal will be sent to recipients by email. If this option is not defined, a value of “all” is taken ip – [optional] SMTP server IP address. This is the SMTP server to connect to for this

particular user. If this option is not defined, the global/default SMTP server is used port – [optional] TCP port of the SMTP server. If this is not defined, the global default

TCP port is used Syntax delete id=<1-5> - delete the specific id specified. The deleted id no longer receives the traps via email.

The id is added using the “add” command Syntax sendmail server=<ip-addr> to=<email-addr> from=<email-addr>

subject=<string> body=<string> - customize (and also to send a test email to check SMTP settings) the email sent out by specifying the email subject field, server address, to field and the body of the text. See example fo the body of the text message later in this chapter server – [mandatory] SMTP server IP v4 address. to – [mandatory] the recipient email address from – [mandatory] the sender email address. subject – [mandatory] email subject or title body – [mandatory] email body Syntax server ip=<ip-addr> [port=<1-65535>] [retry=<0-3>] – configure the global SMTP server

settings ip – [mandatory] SMTP server IP address port – [mandatory] TCP port to be used for SMTP communications – default is 25 retry – [optional] specifies how many times to retry if an error occurs when sending email.

Range from 0 to 3. Default is 0. Syntax smtp <enable|disable> - enables or disables SMTP to send SNMP alerts by email Syntax exportlog mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>]

[doctype=<raw|html>] – facilitates the export of the event log information as a text file or as an HTML file Syntax !! – repeat the last command

Page 278 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 278 · click to enlarge
Page 278

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Syntax !<n> - repeat the “n”th command (as indicated by a show history) Syntax show history – show the last 25 commands executed – if less than 25 commands are executed, only

those commands executed are shown Syntax <Up-arrow> - every time the key is pressed, the last command is printed on the screen but not executed.

This allows for editing errors made in typing Syntax <Down-arrow> - opposite of Up-arrow key Syntax set ftp mode=<normal|passive> - set the ftp mode of operation

Syntax show ftp- display the current ftp operation mode

Syntax show version – displays the version of MNS-6K being used Syntax ping <ipaddress> [count=<1-999>] [timeout=<1-256>] – use the ping command to test

connectivity Syntax set prompt <prompt string> - set the prompt for switch. The prompt has predefined

variables. These are $n : System Name; $c : System Contact; $l : System Location; $i : System IP; $m : System MAC; $v : Version; $$ : $ Character; $r : New Line; $b : Space

Page 279 of the GarrettCom MNS-6K user manual — add id=<vlan Id> [name=<vlan name>] port=<number|list|range> [forbid=<number|list|range>] [<mgt|nomgt>]
Page 279 · click to enlarge
Page 279

APPENDIX

APPENDIX 2 - Commands sorted alphabetically

Command Description !! repeat the last command !<n> repeat the “n”th command (as indicated by a show history)

<command string> <TAB> options for a command <Down-arrow> opposite of Up-arrow key <first character of the command> <TAB>

listing commands starting with the character

<TAB> listing all commands available at the privilege level <Up-arrow> every time the key is pressed, the last command is printed on the screen but not executed. This allows for editing errors made in typing

access setup access configuration parameters action port=<num|list|range> <none|disable|drop>

action to perform in case of breach of port security

add event=<event-id|list|range|all> enables alarm action in response to the specified event ID

add id=<1-5> email=<email-addr> [traps=<all|none|S|R|E>] [events=<all|none|I|A|C|F|D>] [ip=<ip-addr>] [port=<1-65535>]

setup email id for receiving SNMP trap information by email

add id=<vlan Id> [name=<vlan name>] port=<number|list|range> [forbid=<number|list|range>] [<mgt|nomgt>]

add user=<name> level=<number> adding a user

adding VLAN

Page 280 of the GarrettCom MNS-6K user manual — authserver [ip=<ip-addr>] [udp=<num>] [secret=<string>]
Page 280 · click to enlarge
Page 280

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description add port=<number|list|range> [priority=<0-65535>]

add the specified list of ports to form the logical LACP trunk. Default value for priority is 32768. The lower the value assigned to priority, the higher the priority. The port with the highest priority is the primary port (over which certain types of traffic like IGMP is transmitted). Requires the lacp command (module). alarm enter the alarm configuration mode alarm <enable|disable> globally enables or disables the alarm action alarm def-owner=<string> def- comm=<string>

define the RMON alarm group and the community string associated with the group

allow ip=<ipaddress> mask=<netmask> service=<name|list>

allow specific IP address or range of addresses as a trusted host(s)

allow mac=<address|list|range> port=<num|list|range>

specify a specific MAC address or MAC address list

auth configuration mode to configure the 802.1x parameters auth <enable|disable> enables or disables the 802.1x authenticator function on MNS-6K switch

authorize <module> key=<security

activate the S-Ring capabilities. Don’t forget to use the “save” command to save the key

authserver [ip=<ip-addr>] [udp=<num>] [secret=<string>]

define the RADIUS server

authtraps <enable|disable> enables or disables authentication traps generation backend port=<num|list|range> supptimeout=<1-240>] [servertimeout=<1-240>] [maxreq=<1- 10>]

configure parameters for EAP over RADIUS

backpressure rxthreshold=<value> configure backpressure buffers broadcast-protect <enable|disable> protect switch from broadcast storms chlevel user=<name> level=<number> changing the user privilege level

key>

Page 281 of the GarrettCom MNS-6K user manual — com2sec <add|delete> id=<id> [secname=<name>] [source=<source>] [community=<community>]
Page 281 · click to enlarge
Page 281

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description clear <history|log [1..5 |informational |activity |critical |fatal |debug] |terminal |arp|portstats|addr]

clear command to clear various aspects of the MNS-6K information – most notably “clear addr” – clears the addresses learnt or “clear log” to clear the logs (and the type of logs) clear log [fatal|alert|crit|error|warn|note|info|d ebug]

clear logs or specific type of logs

climode <script|console|show> set the interactive CLI mode on (console) or off (script). To see the mode – use the show option

com2sec <add|delete> id=<id> [secname=<name>] [source=<source>] [community=<community>]

a part of the View based Access control model (VACM) as defined in RFC 2275. This specifies the mapping from a source/community pair to a security name. On MNS-6K, up to 10 entries can be specified command <Enter> options for a command community [write=<write community>] [read=<read community>] [trap=<trap community>]

set the necessary community strings

configure access sets the access parameters e.g. disable telnet session cost port=<number|list|range> value=<0-65535>

cost is specific to a port and the port(s) have to be specified

configure port-security sets the port authorization based on MAC addresses configure vlan type=port enter the VLAN configuration commands cost port=<number|list|range> value=<0-65535>

cost is specific to a port and the port(s) have to be specified

deftrap community=<string> defines the default community string to be used when sending traps. When user does not specify the trap community name when setting a trap station using the “trap” command, the default trap community name is used

Page 282 of the GarrettCom MNS-6K user manual — delete user=<name> deleting a user deny ip=<ipaddress> mask=<netmask> service=<name|list>
Page 282 · click to enlarge
Page 282

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description del event=<event-id|list|range|all> disables alarm action in response to the specified event ID

del port=<number|list|range> delete specified ports from the LACP membership. Requires the lacp module. delete id=<1-5> delete the specific id specified. The deleted id no longer receives the traps via email. The id is added using the “add” command

delete user=<name> deleting a user deny ip=<ipaddress> mask=<netmask> service=<name|list>

deny specific IP address or range of IP addresses

device configure device and port specific settings dualhome enter the dual-homing configuration sub-system dualhome <enable|disable> enable or disable dual-homing dualhome add port1=<port#> port2=<port#> OR dualhome add primary=<port#> secondary=<port#>

dual-homing setup similar to that of unmanaged switches such as ESD42 dual-homing setup as primary-secondary mode

dualhome del Delete the dual-homing setup edit id=<vlan id> [name=<vlan name>] port=<number|list|range> [<mgt|nomgt>]

edit existing VLAN name

edit the membership of the ports specified for LACP ports. The priority can be from 0 – 6553. Requires LACP module.

edit port=<number|list|range> [priority=<priority>]

Page 283 of the GarrettCom MNS-6K user manual — flowcontrol xonlimit=<value> xofflimit=<value>
Page 283 · click to enlarge
Page 283

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description enable <user-name> changing the privilege level engineid string=<string> Every agent has to have an engineID (name) to be able to respond to SNMPv3 messages. The default engine ID value is “6K_v3Engine”. This command allows the user to change the engine ID

event def-owner=<string> defcomm=<string>

define the RMON event group and the community string associated with the group

exportlog mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>] [doctype=<raw|html>]

facilitates the export of the event log information as a text file or as an HTML file

flowcontrol xonlimit=<value> xofflimit=<value>

configure flow control buffers

forceversion <stp|rstp> set the STP or RSTP compatibility mode ftp <get|put|list|del> [type=<app|config|oldconf|script|host s|log>] [host=<hostname>] [ip=<ipaddress>] [file=<filename>] [user=<user>] [pass=<password>] – where <get|put|list|del> - different ftp

upload and download information using ftp command. The IP address can be a IPv4 address or an IPv6 address

ts|log>] – optional type field. This is useful to specify whether a log file or host file is uploaded or downloaded. This can also perform the task of exporting a configuration file or uploading a new image to the switch [host=<hostname>] [ip=<ipaddress>]

[file=<filename>] [user=<user>] [pass=<password>] – parameters associated with ftp server for proper communications with the server

operations [type=<app|config|oldconf|script|hos

Page 284 of the GarrettCom MNS-6K user manual — learn port=<number-list> <enable|disable>
Page 284 · click to enlarge
Page 284

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description group <add|delete> id=<id> [groupname=<name>] [model=<v1|v2c|usm>] [com2secid=<com2sec-id>]

a part of the View based Access control model (VACM) as defined in RFC 2275. This command defines the mapping from sec model or a sec name to a group. A sec model is one of v1, v2c, or usm. On MNS-6K, up to 10 entries can be specified gvrp <enable|disable> enable or disable GVRP host <add|edit|del> name=<host-name> [ip=<ipaddress>] [user=<user>] [pass=<password>]

create a host entry for accessing host. This is equivalent to creating a host table on many systems. Maximum of 10 such entries are allowed help <command string> help for a specific command history def-owner=<string> def- comm=<string>

define the RMON history group and the community string associated with the group

igmp IGMP configuration mode igmp <enable/disable> enable or disable IGMP on the switch ipconfig [ip=<ip-address>] [mask=<subnet-mask>] [dgw=<gateway>]

to set IP address on the switch

kill config [save=system] resets the system configuration. The module_name option does not reset the specific module parameters. The modules are system, event, port, bridge, stp, ps, mirror, sntp, vlan, gvrp and snmp kill session id=<session> terminate a telnet session. See also “show session”

enable the LACP configuration module within CLI

lacp <enable | disable> enable or disable LACP

learn port=<number-list> <enable|disable>

learn MAC addresses connected to the Magnum 6K switch

lacp

Page 285 of the GarrettCom MNS-6K user manual — port port=<number|list|range> status=<enable|disable>
Page 285 · click to enlarge
Page 285

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description lll <enable|disable> enable or disable LLL on the switch lll add port=<port|list|range> enable LLL on the list of specified ports lll del port=<port|list|range> disable LLL on the list of specified ports loadconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>]

loading the previously saved configuration from the network using tftp, ftp or serial protocols

logout logout from the CLI session mcast <enable | disable>

enable or disable unknown multicast streams. The default is enabled mgrip <add|delete> ip=<IPaddress> adds or deletes a management station, specified by the IP address, which can query SNMP variables from the switch. This is done to protect the switch from being polled by unauthorized managers. Applicable for SNM v1 only. Maximum of five stations allowed. mode <l2|normal> Set the IGMP mode to be IGMP-L2 mode or normal IGMP mode more <enable|disable|show>

enable or disable the scrolling of lines one page at a time passwd user=<name> changing a password for a user period time=<1..10> sets the duration of relay action for the momentary type signal. This may be needed to adjust to the behavior of the circuit or relay. Default is 3 seconds. Time is in seconds ping <ipaddress> [count=<1-999>] [timeout=<1-256>]

use the ping command to test connectivity

ping6 <ipv6-address> ping an IPv6 station

port port=<number|list|range> [status=<enable|disable>] [migration=<enable>] [edge=<enable|disable>] [p2p=<on|off|auto>]

set the port type for RSTP

port port=<number|list|range> status=<enable|disable>

specific ports may not need to participate in STP process. These ports typically would be end- stations. If you are not sure - let MNS-6K software make the decisions portaccess port=<num|list|range> [quiet=<0-65535>] [maxreauth=<0-10>] [transmit=<1-65535>]

set port access parameters for authenticating PCs or supplicants

Page 286 of the GarrettCom MNS-6K user manual — remove mac=<all|address|list|range> port=<num|list|range>
Page 286 · click to enlarge
Page 286

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description port-mirror <enter> configure port mirror settings port-security configure port security settings priority [port=<number|list|range>] value=<0-255 | 0-65535>

specifies the port or switch level priority. When a port(s) are specified the priority is associated with ports and their value is 0-255. If no ports are specified, then the switch (bridge) priority is specified and its value is 0-65535 priority [port=<number|list|range>] value=<0-255 | 0-65535>

specifies the port or switch level priority. When a port(s) are specified the priority is associated with ports and their value is 0-255. If no ports are specified, then the switch (bridge) priority is specified and its value is 0-65535 prtmr <enable|disable> enable or disable port mirror settings ps <enable|disable> enable or disable port security qos enter the QoS configuration mode quickcfg quick setup for snmpv3 configuration. It automatically configures a default VACM (view- based access control model). This allows any manager station to access the Magnum 6K switch either via SNMP v1, v2c or v3. The community name is “public”. This command is only intended for first time users and values can be changed by administrators who want more strict access rate-threshold port=<port|list|range> rate=<frames/sec>

change the allowed broadcast rate threshold

reauth port=<num|list|range> [status=<enable|disable>] [period=<1086400>]

set values on how the authenticator (Magnum 6K switch) does the re-authentication with the supplicant or PC

reboot restart the switch same effect as physically turning off the power

remove ip=<ipaddress> mask=<netmask>

delete a specific IP address from the access or trusted host list

remove mac=<all|address|list|range> port=<num|list|range>

remove a MAC address entry

removeall remove all IP addresses of trusted hosts

Page 287 of the GarrettCom MNS-6K user manual — set date year=<2001-2035> month=<112> day=<1-31> [format=<mmddyyyy|ddmmyyyy|yyyy mmdd>]
Page 287 · click to enlarge
Page 287

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description rmon enter the RMON configuration mode to setup RMON groups and communities

rs-ring <enable| disable> enable or disable RS-Ring capabilities rs-ring add port=<port1,port2>

define ports which make up the RS-Ring ports. Note as discussed earlier, you can create multiple RS-rings on a switch rs-ring del port=<port1,port2> remove the switch from RS-Ring topology by eliminating the end ports on the switch rstp enter the RSTP configuration mode rstp <enable|disable> enable RSTP – by default, this is disabled and has to be manually activated

save save changes made to the configuration saveconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>]

saving the configuration on the network using tftp, ftp or serial protocols

sendmail server=<ip-addr> to=<email- addr> from=<email-addr> subject=<string> body=<string>

customize (and also to send a test email to check SMTP settings) the email sent out by specifying the email subject field, server address, to field and the body of the text. See example fo the body of the text message later in this chapter

server ip=<ip-addr> [port=<1-65535>] [retry=<0-3>]

configure the global SMTP server settings

set bootmode type=<dhcp|bootp|manual|auto> [bootimg=<enable|disable>] [bootcfg=[<enable|disable>]

assign the boot mode for the switch

set date year=<2001-2035> month=<112> day=<1-31> [format=<mmddyyyy|ddmmyyyy|yyyy mmdd>]

sets the date and the format in which the date is displayed

set daylight country=< country name> set the daylight saving time

Page 288 of the GarrettCom MNS-6K user manual — set time hour=<0-23> min=<0-59> sec=<0-59> [zone=GMT[+/-]hh:mm]
Page 288 · click to enlarge
Page 288

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description set ftp mode=<normal|passive> set the ftp mode of operation

set the IGMP mode. Normal is when a L3 device is in the network and is the IGMP root. The IGMP-L2 is used when there is no L3 device in the network set logsize size=<1-1000> set the log buffer size set password set or change password set prompt <prompt string>

set igmp mode= <normal|l2>

set the prompt for switch. The prompt has predefined variables. These are $n : System Name; $c : System Contact; $l : System Location; $i : System IP; $m : System MAC; $v : Version; $$ : $ Character; $r : New Line; $b : Space set serial [baud=<rate>] [data=<5|6|7|8>] [parity=<none|odd|even>] [stop=<1|1.5|2>] [flowctrl=<none|xonxoff>]

set serial port parameters

set snmp type=<v1|all> define the version of SNMP to use – the option all supports all versions (v1, v2 and v3) – v1 restricts SNMP to v1 only. By default – SNMP v1only is enabled

set stp type=<stp|rstp> Set the switch to support RSTP or change it back to STP. Need to save and reboot the switch after this command

set time hour=<0-23> min=<0-59> sec=<0-59> [zone=GMT[+/-]hh:mm]

sets the time (as well as the timezone)

set timeformat format=<12|24> set the display time in the 12/24 hour mode set timezone GMT=[+ or -] hour=<0- 14> min=<0-59> sets the timezone

Page 289 of the GarrettCom MNS-6K user manual — set-port port=<number|list|range> tagging id=<number> status=<tagged| untagged>
Page 289 · click to enlarge
Page 289

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description set vlan type=<port|tag|none> defines the VLAN type set-forbid vlan=<tag vlanid> forbid=<port-number|list|range>

sets the forbid GVRP capability on the ports specified

set-leave <enable|disable> enables or disables the switch to immediately process a host sending a leave message rather that wait for the timer to expire

setport monitor=<monitor port number> sniffer=<sniffer port number>

set port mirror settings

set-port port=< port|list|range> mode=<auto|forward|block>

set the port characteristics for IGMP. Block drops the unregistered multicasts. Forward forwards unregistered multicasts set-port port=<number|list|range> default id=<number>

sets the default VLAN id. For Magnum 6K family of switches, the default VLAN id is 1, unless changed using this command

set-port port=<number|list|range> filter status=<enable|disable>

enables or disables the VLAN filtering function.

set-port port=<number|list|range> join id=<number>

adds the specified port(s) to the specified VLAN id

set-port port=<number|list|range> leave id=<number>

releases a specific port from a VLAN

set-port port=<number|list|range> tagging id=<number> status=<tagged| untagged>

defines whether the outgoing packets from a port will be tagged or untagged.

Page 290 of the GarrettCom MNS-6K user manual — setport port=<port#|list|range> [name=<name>] [speed=<10|100>] [duplex=<half|full>] [auto=<enable|disable>] [flow=<enable|disable>] [bp=<enable|disable>] [status=<enable|disable>]
Page 290 · click to enlarge
Page 290

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description setport port=<num|list|range> [status=<enable|disable>] [control=<auto|forceauth|forceunauth> ] [initialize=<assert|deassert>]

setting the port characteristic for an 802.1x network

setport port=<port#|list|range> [name=<name>] [speed=<10|100>] [duplex=<half|full>] [auto=<enable|disable>] [flow=<enable|disable>] [bp=<enable|disable>] [status=<enable|disable>]

set-ports port=<port|list|range> state=<learn|block|disable>

set the state of the port to learn, block or disable for GVRP. Note the default state is disable

Set the prompt string

set prompt <prompt string> The length of the prompt is limited to 60 characters. The predefined variables are $n: System Name $c: System Contact $l: System Location $i : System IP $m: System MAC $v: Version $$ : $ Character $r: New Line $b: Space

configure port settings

Page 291 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 291 · click to enlarge
Page 291

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description set-qi interval=<value> The IGMP querier router periodically sends general host-query messages. These messages are sent to ask for group membership information. This is sent to the all-system multicast group address, 224.0.0.1. The default value is 125 seconds. The valid range can be from 60 to 127 seconds. set qos type=<port|tag|tos|none> port=<port|list|range> [priority=<high|low>] [tos=<0- 63|list|range>][tag=<0-7|list|range>]

depending on the type of QOS, the corresponding field has to be set. For example, for QOS type tag, the tag levels have to be set, and for QOS type ToS, the ToS levels have to be set. If the priority field is not set, it then defaults to low priority. ToS has 64 levels and the valid values are 0-63 and a tagged packet has 8 levels and the valid values are 0-7. set-qri interval=<value> The query response interval is the maximum amount of time that can elapse between when the querier router sends a host-query message and when it receives a response from a host. The Default value is 10 seconds. The Range can be from 2 to 270 seconds. Restrictions apply to the maximum value because of an internal calculation that is dependent on the value of the Query Interval. set-querier <enable|disable> enables or disables a switch as IGMP querier setsntp server = <ipaddress> timeout = <1-10> retry = <1-3>

setup the SNTP server

Page 292 of the GarrettCom MNS-6K user manual — setvar [sysname|syscontact|syslocation]=<stri ng>
Page 292 · click to enlarge
Page 292

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description set-untag port=<port|list|range> priority=<high|low> tag=<0-7>

The 802.1p user priority assigned to untagged received packets to be transmitted as tagged from the priority queue

setvar [sysname|syscontact|syslocation]=<stri ng>

set the system name, contact and location information

setvar [sysname|syscontact|syslocation]=<stri ng>

sets the system name, contact and location. All parameters are optional but a user must supply at least one parameter

set-weight weight=<0-7> sets the port priority weight for All the ports. Once the weight is set, all the ports will be the same weight across the switch. The valid value for weight is 0-7 show address-table displays which mac address is associated with which port for packet switching show active-stp status whether STP or RSTP is running Show active-snmp display the version of SNMP currently in use show alarm displays the current status of Alarm system show auth <config|ports> show the 802.1x configuration or port status show backpressure display backpressure buffers show config show setup parameters configured show console displays the console settings show date displays the date show dualhome Display dual-homing status show flowcontrol display flow control buffers show ftp display the current ftp operation mode

show gvrp shows whether GVRP is disabled, along with the current settings for the maximum number of VLANs and the current Primary VLAN

show history show the last 25 commands executed – if less than 25 commands are executed, only those commands executed are shown

Page 293 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 293 · click to enlarge
Page 293

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description show host display the hosts table entries show igmp IGMP operation status show ip-access display all trusted hosts show ipconfig shows the IP parameters set in the switch show lacp displays the status and other relevant LACP information show lll display the status of LLL show log [fatal|alert|crit|error|warn|note|info|d ebug]

display logs and specific types of logs

show port[=<Port number>] display port settings show port-mirror display port mirror settings show port-security display port security settings show qos [type=<port|tag|tos>] [port=<port|list|range>]

displays the QoS settings

show rmon <stats|hist|event|alarm> list the specific RMON data as defined by the group type

show rs-ring show the status of RS-Ring show serial displays the serial port settings show session Display the current telnet sessions. See also “kill session” show setup displays the system parameters setup on the system show setup show setup parameters show smtp <config|recipients> config – displays the current SMTP global settings and recipients displays the currently configured recipients of email alerts

Page 294 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 294 · click to enlarge
Page 294

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description show snmp displays the SNMP configuration information show s-ring show the status of S-Ring show stp <config|ports > regardless of whether STP is enabled or disabled (default) this command lists the switch’s full STP configuration, including general settings and port settings show stp <config|ports> display the RSTP or STP parameters show sysconfig displays the settable system parameters show tacplus <status|servers> show status of TACACS or servers configured as TACACS+ servers

show time displays the system time show timezone displays the timezone information show uptime displays the amount the time elapsed since the last reboot or power failure

show version displays the version of MNS-6K being used show vlan type=<port|tag> [<id=vlanid>]

display specific VLAN information

show-authtrap displays the current value of authentication trap status show-deftrap displays the current value of default trap show-forbid display the ports with GVRP forbid capabilities show-forceversion the current forced version show-group shows the multicast groups show-group [id=<id>] display all or specific group entries - id is optional and is the number corresponding to the group entry number in the table

show-port display the port characteristics for IGMP show-port [port=<port|list|range>] shows all parameters related to tag vlan for the list of ports. If the port parameter is omitted, it will display all ports

show-portweight display the weight settings on a port

Page 295 of the GarrettCom MNS-6K user manual — signal port=<num|list|range> <none|log|trap|logandtrap>
Page 295 · click to enlarge
Page 295

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description show-router displays detected IGMP-enabled router ports show-stats port=<num> displays 802.1x related statistics

show-timers show the values of the timers set for RSTP show-trap [id=<id#>] shows the configured trap stations in tabular format - id is optional and is the number corresponding to the trap entry number in the table show-user [id=<id>] display all or specific view entries - id is optional and is the number corresponding to the view entry number in the table

show-view [id=<id>] display all or specific view entries - id is optional and is the number corresponding to the view entry number in the table

show-vlan list all the VLANs (including dynamic VLANs) on the switch

signal port=<num|list|range> <none|log|trap|logandtrap>

port to monitor and signal to send in case of breach of port security

smtp configure the SNMP alerts to be sent via email smtp <enable|disable> enables or disables SMTP to send SNMP alerts by email snmp enter the SNMP Configuration mode snmpv3 enter the SNMP V3 configuration mode – note enable SNMP V3 by using the “set snmp” command which follows

sntp [enable|disable] enable or disable the SNTP services s-ring <enable/disable> enable or disable S-ring capabilities s-ring add port=<port1,port2> define ports which make up the s-ring ports. Note as discussed earlier, you can create multiple s-rings on a switch

s-ring del port=<port1,port2> remove the switch from S-ring topology by eliminating the end ports on the switch

s-ring learn start the learning process to discover the ring and the ports which make up the s-ring

Page 296 of the GarrettCom MNS-6K user manual — [ip=<ip-addr>] [port=<tcpport>] [encrypt=<enable|disable>] [key=<string>] [mgrlevel=<level>] [oprlevel=<level>]
Page 296 · click to enlarge
Page 296

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description start vlan=<name|number|list|range> activate the VLAN configuration static vlan=<VID> convert a dynamic VLAN to a static VLAN statistics def-owner=<string> def- comm=<string>

define the RMON statistics group and the community string associated with the group

stp STP Configuration mode stp <enable|disable> Start (Enable) or stop (Disable) STP sync [hour=<0-24>] [min=<0-59>] setup the frequency at which the SNTP server is queried tacplus <enable|disable> [

enable or disable TACACS authentication, specifying the order in which the server or local database is looked up where “tac,local” implies, first the TACAS+ server, then local logins on the device tacserver <add|delete> id=<num>

adds a list of up to five TACACS+ servers where <add|delete> – [mandatory] adds or delete a TACACS+ server. id=<num> – [mandatory] the order in which the TACACS+ servers should be polled for authenticaton [ip=<ip-addr>] – [mandatory for add] the IP address of the TACACS+ server [port=<tcp-port>] – [optional for add] TCP port number on which the server is listening [encrypt=<enable|disable>] – [optional for add] enable or disable packet encryption [key=<string>] – [optional for add, mandatory with encrypt] when encryption is enabled, the secret shared key string must be supplied [mgrlevel=<level>] and [oprlevel=<level>] – [optional] specifies the manager and operator level as defined on the TACACS+ server for the respective level of login telnet <enable|disable> enable or disable telnet sessions telnet <ipaddress> [port=<port number>]

[ip=<ip-addr>] [port=<tcpport>] [encrypt=<enable|disable>] [key=<string>] [mgrlevel=<level>] [oprlevel=<level>]

telnet from the switch. The IP address can be an IPv4 address or an IPv6 address

order=<tac,local | local,tac>]

Page 297 of the GarrettCom MNS-6K user manual — trap <add|delete> id=<id> [type=<v1|v2|inform>] [host=<hostip>] [community=<string>] [port=<165534>]
Page 297 · click to enlarge
Page 297

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description timers forward-delay=<4-30> hello=<1- 10> age=<6-40> change the STP Forward Delay, Hello timer and Aging timer values

tftp <get|put> [type=<app|config|oldconf|script|host s|log>] [host=<hostname>] [ip=<ipaddress>] [file=<filename>] where <get|put> - different tftp operations – get a file from the server or put the information on the server [type=<app|config|oldconf|script|ho sts|log>] – optional type field. This is useful to specify whether a log file or host file is uploaded or downloaded. This can also perform the task of exporting a configuration file or uploading a new image to the switch [host=<hostname>] [ip=<ipaddress>] [file=<filename>] – parameters associated with tftp server for proper communications with the server

upload and download information using tftp command

traps <add|delete> type=<Snmp|Rmon|Snmp,Rmon| Enterprise| Snmp,Enterprise |Rmon,Enterprise|All> ip=<ipaddress>

add SNMP v1 traps as well as define the trap receiver

trap <add|delete> id=<id> [type=<v1|v2|inform>] [host=<hostip>] [community=<string>] [port=<165534>]

define the trap and inform manager stations. The station can receive v1, v2 traps and/or inform notifications. An inform notification is an acknowledgments that a trap has been received. A user can add up to 5 stations.

trigger-reauth port=<num|list|range> manually initiate a re-authentication of supplicant

Page 298 of the GarrettCom MNS-6K user manual — view <add|delete> id=<id> [viewname=<name>] [type=<included|excluded>] [subtree=<oid>] [mask=<hex-string>]
Page 298 · click to enlarge
Page 298

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Command Description user <add|delete> id=<id> [username=<name>] [usertype=<readonly|readwrite>] [authpass=<pass-phrase>] [privpass=<pass-phrase>] [level=<noauth|auth|priv>] [subtree=<oid>]

for quickly adding or deleting v3 USM based security, this command adds user entries. MNS- 6K allows up to 5 users to be added. Right now, the MNS-6K agent only support noauth and auth-md5 for v3 authentication and auth-des for priv authentication

useraccess user=<name> service=<telnet|web> <enable|disable> where user=<name> specifies the user id service=<telnet|web> specifies which service (telnet or web) the user has access to <enable|disable> specifies whether the services are allowed or not allowed

For assigning access capabilities to the user – for example to allow or not allow telnet access to the switch

a part of the View based Access control model (VACM) as defined in RFC 2275. This command defines a manager or group or manager stations what it can access inside the MIB object tree. On MNS-6K, up to 10 entries can be specified xmodem <get|put> [type=<app|config|oldconf|script|host s|log>] where <get|put> - different xmodem file transfer operations – get a file from the server or put the information on the server [type=<app|config|oldconf|script|host s|log>] – optional type field. This is useful to specify whether a log file or host file is uploaded or downloaded. This can also perform the task of exporting a configurat

view <add|delete> id=<id> [viewname=<name>] [type=<included|excluded>] [subtree=<oid>] [mask=<hex-string>]

upload and download information using xmodem command and console connection

vlan type=port enter the VLAN configuration commands

Page 299 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 299 · click to enlarge
Page 299

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Intentionally left blank

Page 300 of the GarrettCom MNS-6K user manual — Alaska
Page 300 · click to enlarge
Page 300

APPENDIX

APPENDIX 3 - Daylight Savings

No time like the present...

Daylight Savings Time

Magnum6K Switches provide a way to automatically adjust the system clock for Daylight Savings Time (DST) changes. In addition to the value "none" (no time changes), there are fifteen pre- defined settings, a few examples are:

  • Alaska
  • Canada and Continental US
  • Middle Europe and Portugal
  • Southern Hemisphere
  • Western Europe The pre-defined settings follow these rules:

Alaska

  • Begin DST at 2am the first Sunday on or after April 24 th
  • End DST at 2am the first Sunday on or after October 25 th Canada and Continental US
  • Begin DST at 2am the first Sunday on or after April 1 st
  • End DST at 2am the first Sunday on or after October 25 th Middle Europe and Portugal
  • Begin DST at 2am the first Sunday on or after March 25 th
  • End DST at 2am the first Sunday on or after September 24 th Southern Hemisphere
  • Begin DST at 2am the first Sunday on or after October 25 th
  • End DST at 2am the first Sunday on or after March 1 st Western Europe:
  • Begin DST at 2am the first Sunday on or after March 23 rd
  • End DST at 2am the first Sunday on or after October 23 rd Daylight saving time is defined for the following countries
Page 301 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 301 · click to enlarge
Page 301

M A G N U M 6 K S W I T C H E S , M N S - 6 K U S E R G U I D E

Australia, Belgium, Canada, Chile, Cuba, Egypt, France, Finland, Germany, Greece, Iraq, Italy, London, Namibia, Portugal, Russia, Spain, Sweden, Switzerland, Syria, USA Note – as of Release 3.7, the new daylight saving times dates enforced as of 2007, for the

time zones and states in US, have been implemented in MNS-6K

Page 302 of the GarrettCom MNS-6K user manual — APPENDIX
Page 302 · click to enlarge
Page 302

U P D A T I N G M N S - 6 K

APPENDIX

APPENDIX 4 – Updating MNS-6K Software

Keep up to date

The steps required to update the MNS-6K software on your Magnum switch are listed.

Intentionally left blank

Page 303 of the GarrettCom MNS-6K user manual — Step 1
Page 303 · click to enlarge
Page 303

U P D A T I N G M N S - 6 K – S T E P 1

Step 1

1. Getting Started

Decide which version to use…..

his document describes how to upgrade the MNS-6K software on a Magnum 6K switch. The methods described for updating the MNS-6K software are either locally at the console port on the Magnum 6K switch or remotely over the network using FTP or TFTP. This step involves getting ready with the necessary software and hardware tools as well as deciding on which MNS-6K software version to update to. T

Depending on the update process (update through the serial/console port or remotely through the network), it would be best if the necessary tools listed below are available, tested and working before you start.

For serial port updates directly through the serial/console port 7) A female-female null modem cable. This cable is available from GarrettCom, Inc. as well as from LANstore, Inc. (http://www.lanstore.com) 8) Serial port – if your PC does not have a serial port, you may want to invest in a USB to serial converter. This is again available from LANstore or from GarrettCom. Alternately a USB to serial cable can also be used. This cable is available also available from LAN store or GarrettCom Inc. 9) A PC (or a workstation/computer) with a terminal emulation program such as HyperTerminal (included with Windows) or Teraterm-pro or other equivalent software. Make sure that the software supports Xmodem protocol 10) Enough disk space to store and retrieve the configuration files as well as copy software files from GarrettCom. We recommend that at least 15MB of disk space is available for this purpose 11) Manager level account name and password of the switch being upgraded 12) Connection to the Internet. Make sure the connection does not block ftp file transfers

For remote updates over the network 1) A PC (or a workstation/computer) with a FTP as well as TFTP server software. This software is widely available as a free download on the Internet. If you need assistance in finding one, contact GarrettCom tech support at (510) 438-9071, email – support@garrettcom.com

Page 304 of the GarrettCom MNS-6K user manual — Downloading the MNS-6K software
Page 304 · click to enlarge
Page 304

U P D A T I N G M N S - 6 K – S T E P 1

2) Enough disk space to store and retrieve the configuration files as well as copy software files from GarrettCom. We recommend at least 15MB of disk space for this purpose 3) Connection to the Internet. Make sure the connection does not block FTP file transfers 4) IP address of the switch that is being upgraded. Along with that, the manager level account name and password is also needed 5) Connection to the GarrettCom Magnum 6K switch. Make sure the Intranet over which the software update will occur does not block FTP or TFTP traffic.

Selecting the proper version

The first step is to ensure that you have the proper version of the MNS-6K software. To access the proper software, you will require access to the GarrettCom web site (and ftp site) through a network which does not block ftp file transfers. If your site blocks ftp file transfer traffic, please contact your system administrator to figure out how to access the GarrettCom site to download the necessary software.

First determine the version of the software on your switch. To do that, use the command ‘show version’ after connecting to the switch and logging in as manager, with the proper password. If the password is lost or forgotten, please contact GarrettCom Inc customer support at Phone (510) 438-9071, email – support@garrettcom.com.

The table below lists the current MNS-6K version number and software version upgrade path for the MNS-6K.

Table A4-1 – Software upgrade matrix

Existing software version

Upgrade Path What to do

Version 1.0 to Version 2.5 Contact GarrettCom customer support to upgrade the software Version 2.5.x or higher Latest Version of MNS-6K

Download latest version of MNS-6K from ftp://ftp.garrettcom.com/ following the steps listed below

Downloading the MNS-6K software

To download the MNS-6K software, follow these simple steps:

1. Access GarrettCom’s FTP site through any standard browser ftp://ftp.garrettcom.com a) (Note: Make sure the browser has – “enable the ftp view” option checked. For

Internet Explorer it can be enabled by using the menu ToolsÆ Internet options Æ Advanced). If you are running a personal firewall or other firewall software, please ensure that ftp protocol is allowed on the computer or the network.

Page 305 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 305 · click to enlarge
Page 305

U P D A T I N G M N S - 6 K – S T E P 1

b) If the site uses another socket number for ftp connections, use the socket number at

the end of the URL. For example, if the network administrator has setup a firewall to use socket number 1684, the URL would be as follows: ftp://ftp.garrettcom.com:1684 c) NOTE - You can use any other FTP program available on the Internet, including

the ‘ftp’ command available on most operating systems instead of the browser for downloading the software.

Remember the file name and the directory where the MNS-6K software is stored. This will be needed later for the upgrade – irrespective of whether the MNS-6K software is updated via the serial port or over the network. NOTE – the common error is to use ftp://www.garrettcom.com – this URL will not work. It will give you an error. Please use ftp://ftp.garrettcom.com 2) Once the connection is established, use the user login as m6kuser and the password as m6kuser – see Figure 1. If you have previously established a different login/password for the GarrettCom site, that login name and password can be used as well.

Intentionally left blank for image continuity – image shown on next page

Page 306 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 306 · click to enlarge
Page 306

U P D A T I N G M N S - 6 K – S T E P 1

GarrettCom MNS-6K — SNMP concepts diagram (page 306)
Fig. 21 · SNMP concepts

FIGURE 141 – Accessing the GarrettCom site for download.

ftp://m6kuser:m6kuser@ftp.garrettcom.com 3) After successful login, select the proper folder for downloading the proper MNS-6K software, as shown in Figure 2. Select the MNS-6K software version based on the information provided in Table 1.

Page 307 of the GarrettCom MNS-6K user manual — SNMP concepts
Page 307 · click to enlarge
Page 307

U P D A T I N G M N S - 6 K – S T E P 1

GarrettCom MNS-6K — SNMP concepts diagram (page 307)
Fig. 22 · SNMP concepts

FIGURE 142 – Select the proper version to use after successful login

4) Navigate to the folder MNS-6K. See Figure 3. (There are other folders with additional software, MIBs as well as additional useful information for the Magnum-6K switches which you may want to use later.) From the MNS-6K folder download the latest ‘Release Notes’ as well as the file labeled Relx.x.bin (where x.x would be the release number. For example for release 3.0, the file will be Rel3.0.bin). The release numbers increase with new releases, so the higher the number, the recent the release is. The release notes provide additional information on the latest features and functionality plus any other additional information not covered in the manuals.

GarrettCom MNS-6K — SNMP concepts diagram (page 307)
Fig. 23 · SNMP concepts

FIGURE 143 – Navigate to MNS-6K folder to download the latest MNS-6K software and the release notes

5. Copy the necessary files by using the copy command. This can be done by using the right click (or for left handed mouse – the left click) button and then selecting the copy command. See Figure 4. (Note - Linux or other operating system users – please use the appropriate copy command.) a) If you are using another ftp program, use that programs copy command. Make sure

to download the Rel.x.x.bin file in the binary mode (especially if you are using a command line ftp command), or the MNS-6K image may be corrupted.

Page 308 of the GarrettCom MNS-6K user manual — Next steps
Page 308 · click to enlarge
Page 308

U P D A T I N G M N S - 6 K – S T E P 1

GarrettCom MNS-6K — SNMP concepts diagram (page 308)
Fig. 24 · SNMP concepts

FIGURE 144 – Use the copy command to copy the files to the proper location

6. Make sure you remember where the files are stored as these files will be needed for the next step.

Next steps

1) Access the GarrettCom Magnum 6K switch. The access can be over the console port using the null modem cable or through the network using telnet. This is described in step 2. 2) Save the existing configuration (either through the serial port or through the network – depending on the access method). This is also described in step 2. 3) Load the updated MNS-6K software and reboot the switch. This is described in step 3. 4) (Optional step) Reload the saved configuration. This is described in step 4.

Page 309 of the GarrettCom MNS-6K user manual — Accessing the switch
Page 309 · click to enlarge
Page 309

U P D A T I N G S O F T W A R E – S T E P 2

Step 2

2. Preparing to load the software

Backup your existing configuration…..

nce the MNS-6K software is downloaded from the GarrettCom site, it is strongly recommended that the existing configuration of the switch is preserved before the MNS-6K software upgrade is performed. This section will show you how to save the existing configuration and prepare you for loading the configuration. O

Accessing the switch

The MNS-6K User Guide explains how the switch can be accessed. For clarity, this section simplifies the details and describes some of the commands you can use for accessing the switch.

The Magnum 6K switch can be accessed via the serial port or through the network using telnet. For using telnet, make sure the switch is configured with the proper IP address, netmask and default gateway information. If needed, refer to Chapter 1 of the User Guide on how to set IP address and related parameters on the Magnum 6K switch.

Make sure the Manager level login name and password associated with that switch is also known. Without the proper access (login name and password) the switch cannot be upgraded.

Serial Connection Connect the serial port on the switch to the serial port on the computer using the serial cable listed in step 1. The settings for the HyperTerminal software emulating a VT100 are shown in Figure 5 below. Make sure the serial parameters are set as shown (or bps = 38400, data bits=8, parity=none, stop bits=1, flow control=none).

Page 310 of the GarrettCom MNS-6K user manual — Saving the Configuration
Page 310 · click to enlarge
Page 310

U P D A T I N G S O F T W A R E – S T E P 2

FIGURE 145 - HyperTerminal screen showing the serial settings

Network Access Prerequisites - a PC (or workstation/computer) with telnet software and the IP address of the Magnum 6K switch (or DNS name associated with the switch) to be upgraded. Access the Magnum 6K switch by using the telnet command. For example, if the switch has the IP address 192.168.10.11 the command is as shown in Figure 6 below.

C:> telnet 192.168.10.11

Trying ….. connected…

FIGURE 146 – Using telnet command to connect to a Magnum 6K switch with IP address 192.168.10.11

If the telnet command does not work – check for network connectivity (using the ‘ping’ command). Please ensure that a personal firewall or other firewall settings are not affecting ping or telnet commands. If telnet services fail10 then the alternative is to locate the Magnum 6K switch and update the MNS-6K software through the serial port following the serial update process described in this document.

Saving the Configuration

Before saving the configuration, please ensure that one of the three capabilities listed below are available

10 telnet services can fail due to a number of reasons. Please check with your system and/or network administrator for additional help.

Page 311 of the GarrettCom MNS-6K user manual — Serial Connection
Page 311 · click to enlarge
Page 311

U P D A T I N G S O F T W A R E – S T E P 2

1. Serial file transfer capability such as X-modem or equivalent
2. TFTP server
3. FTP server

As a good practice, GarrettCom recommends that you should have all these capabilities available on your local computer if you plan to upgrade additional switches as well as switches in the future.

The command used for saving the existing configuration of the Magnum 6K switch is ‘saveconf’

Syntax saveconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>] Where the [ipaddress] is the IP Address of the server running the TFTP services or the FTP services. The field is needed if either the TFTP or FTP is the mode chosen. File= is needed for saving the configuration

If mode= is used, be aware that most FTP and TFTP services, as a default, do not over-write files. If the file transfer fails, check to see if the file name already exists or use a different file name with the ‘saveconf’ command. Also make sure the ftp or TFTP/FTP services are running before the ‘saveconf’ command is used on the switch.

Serial Connection To save the configuration using the serial connection, use the ‘saveconf’ command as shown below. In this example, we will show the ‘saveconf’ interaction using the Hyper- Terminal software available on most Windows® systems.

Magnum6K25# saveconf mode=serial file=6kconfig-10.11

Do you wish to upload the configuration? [ 'Y' or 'N'] Y

(Use XMODEM to download configuration file)

FIGURE 147 – Example of saveconf command using serial interface

At this point, switch to the VT100 emulation software (e.g. HyperTerminal on Windows platform) and invoke the Xmodem file receive. Figure 8 shows the Xmodem process for HyperTerminal application.

Intentionally left blank for image continuity – image shown on next page

Page 312 of the GarrettCom MNS-6K user manual — Serial Connection
Page 312 · click to enlarge
Page 312

U P D A T I N G S O F T W A R E – S T E P 2

GarrettCom MNS-6K — Serial Connection diagram (page 312)
Fig. 25 · Serial Connection

FIGURE 148 – Invoke the “Receive File” to start the Xmodem transfer program. In the figure above the Windows XP based HyperTerminal screen is shown

Once the “Receive File” is invoked (as shown in Figure 8) follow the dialog to save the file in the proper directory with the proper name as shown in Figure 9.

GarrettCom MNS-6K — Serial Connection diagram (page 312)
Fig. 26 · Serial Connection

FIGURE 149 – Make sure to select the Xmodem protocol and the proper directory where the configuration is saved. Click on Receive. This starts the file transfer.

Once the file transfer is started, the Xmodem status window is shown in Figure 10.

Page 313 of the GarrettCom MNS-6K user manual — Network Access
Page 313 · click to enlarge
Page 313

U P D A T I N G S O F T W A R E – S T E P 2

GarrettCom MNS-6K — Network Access diagram (page 313)
Fig. 27 · Network Access

FIGURE 150 – Status window for Xmodem (using HyperTerminal under Windows XP)

When the file transfer is completed, the window shown in Figure 10 exits and the completion message is displayed as shown in Figure 11.

Successfully uploaded the configuration

FIGURE 151 – Message which shows the completion of the file transfer (from ‘saveconf’ command)

Network Access Prerequisites – PC (or workstation/computer) with telnet software and a PC (or workstation/computer) with FTP or TFTP server software. For simplicity, the two PC’s (or workstations/computers) can be one and the same.

To save using TFTP or FTP first ensure that you have the FTP or TFTP server set up and the switch can ‘ping’ the TFTP or the FTP server. For ftp services, make sure the server can support anonymous login or make sure the login password information is available.

For saving the configuration, use the same saveconf command listed above. In the example below, assume the IP address of the TFTP or FTP server is 192.168.10.99 and is connected to the switch with proper network connectivity (i.e. the switch can ping the TFTP or FTP server as well.)

Magnum6K25# saveconf mode=tftp 192.168.10.99 file=6kconfig-10.11

Do you wish to upload the configuration? [ 'Y' or 'N'] Y

FIGURE 152 – Example of saveconf command for tftp

Magnum6K25# · Example using TFTP

Page 314 of the GarrettCom MNS-6K user manual — Next steps
Page 314 · click to enlarge
Page 314

U P D A T I N G S O F T W A R E – S T E P 2

This will save the file 6kconfig-10.11 to the specified IP address (192.168.10.99) in the default TFTP folder.

Using FTP would be the same as Figure 12, except replace 'mode=tftp' with 'mode=ftp'

In some situations (e.g. routed networks), TFTP or FTP services may be blocked. Check for network connectivity (using the ‘ping’ command). If the connectivity is OK, please contact your system or network administrator to unblock FTP or TFTP packets. If that is not possible, the alternative then is to locate the Magnum 6K switch and update the MNS-6K software through the serial port as described in this document.

Next steps

1. Upload the updated MNS-6K software and reboot the switch. This is described in step 3. 2) (Optional step) Reload the saved configuration. This is described in step 4.
Page 315 of the GarrettCom MNS-6K user manual — Accessing the switch
Page 315 · click to enlarge
Page 315

U P D A T I N G S O F T W A R E – S T E P 3

Step 3

3. Loading the MNS-6K software

Load the new version of the MNS-6K image…..

T this stage, the Magnum MNS-6K software has been downloaded from the GarrettCom site, and the configuration saved. The Magnum-6K switch is now ready to upload the new MNS-6K software image. A

Before loading the MNS-6K software

It will be necessary for the Magnum 6K switch to be reset or re-booted after the new MNS-6K software is loaded. Since this may cause a network outage, software upgrades should be performed when it is tolerable for the outage and the appropriate users are informed of this outage.

Alternately, if the S-Ring technology is used, the outage will not be noticeable and the switch will be re-inserted in the S-Ring after the upgrade is performed. It is however a good practice to inform the affected people of a possible outage.

Accessing the switch

Continue to use the access method defined in steps 1 and 2.

The command used for upgrade is

Syntax upgrade mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>]

mode is the mode by which the software will be accessed for upload – serial, ftp or tftp

ipaddress is the IP address of the ftp or tftp server (only used when mode = ftp or tftp)

file=name is the name of the MNS-6K software file to be used for upgrade. This file was downloaded from the GarrettCom site (as described in steps 1 and 2).

Where

Page 316 of the GarrettCom MNS-6K user manual — Serial Connection
Page 316 · click to enlarge
Page 316

U P D A T I N G S O F T W A R E – S T E P 3

Serial Connection Prerequisites - make sure the directory and the file name of the MNS-6K software image downloaded in steps 1 and 2 is known. To use the serial connection to update the MNS-6K image, the command dialog is shown below:

Version 2.6.0, Build DateJan 29 2004, Time: 12:02:32

Do you wish to upgrade the image? [ 'Y' or 'N'] Y

FIGURE 153 – Upgrade using serial connection

Once the upgrade process is started, the VT100 emulation software (e.g. HyperTerminal) will ask for the file location. Once the file location is indicated, the file transfer begins. Make sure the Xmodem protocol is also selected in this file location dialog window. Once selected, the file transfer begins. The file transfer status window is shown in Figure 14.

GarrettCom MNS-6K — Serial Connection diagram (page 316)
Fig. 28 · Serial Connection

FIGURE 154 – File upload status window under Xmodem (using HyperTerminal under Windows XP)

Once the transfer is complete, the dialog is shown in Figure 15.

Magnum6K25# show version · Magnum6K25# upgrade mode=serial

Page 317 of the GarrettCom MNS-6K user manual — Network Access
Page 317 · click to enlarge
Page 317

U P D A T I N G S O F T W A R E – S T E P 3

Upgrade is Successful. Please reboot Magnum 6Kxx to start the application

Proceed on rebooting the switch? [ 'Y' or 'N' ] Y

Do you wish to save current configuration? [ 'Y' or 'N' ] Y

(The switch will now reboot. After the reboot, the Magnum 6K switch may prompt you should the boot code need an update. If prompted, say “Y” to update the boot code. After the reboot and login verify the MNS-6K software was upgraded.)

MNS-6K Ver3.4 Date:Mar 31 2006 Time:17:06:23 Build ID 1143853580

FIGURE 155 – upgrading the switch using the serial interface

Network Access Prerequisites - make sure the directory and the file name of the MNS-6K software image downloaded in steps 1 and 2 is known. To upgrade using TFTP or FTP, ensure that the FTP or TFTP server is set up and the switch can ‘ping’ the TFTP or the FTP server and vice-versa. Ensure that the server has access to the MNS-6K software image downloaded in step 2. Make sure the MNS-6K software image file is copied to the default folder specified by the FTP or TFTP server. If using FTP services, make sure the FTP access information (login name and password) is also known.

In the example below, let us assume that the IP address of the TFTP server is 192.168.10.99; that the server can ping the switch and the switch can ping the server.

Intentionally left blank for image continuity – image shown on next page

Magnum6K25# reboot · Magnum6K25# show version

Page 318 of the GarrettCom MNS-6K user manual — Next steps
Page 318 · click to enlarge
Page 318

U P D A T I N G S O F T W A R E – S T E P 3

Version 2.6.0, Build DateJan 29 2004, Time: 12:02:32

Magnum6K25# upgrade mode=tftp 192.168.10.99 file=Rel3.0.bin

Do you wish to upgrade the image? [ 'Y' or 'N'] Y

Upgrade is Successful. Please reboot Magnum 6Kxx to start the application

Proceed on rebooting the switch? [ 'Y' or 'N' ] Y

Do you wish to save current configuration? [ 'Y' or 'N' ] Y

(The switch will now reboot. Reconnect and login. Verify the MNS-6K software was upgraded. Note – as discussed in step 1, the switch may need a boot code update. After a reboot, the switch awaits a “Y” or “N” on whether the boot code should be updated. If no answer is given, the default is not to update the boot code (or a “N”). Since this connection is over the network the question will not be visible and the boot code will not be automatically updated. See step 4 – updating boot code over the network on how to update the boot code manually.)

MNS-6K Ver3.4 Date:Mar 31 2006 Time:17:06:23 Build ID 1143853580

FIGURE 156 – Dialog for upgrading the image using tftp

This will load the Rel3.0.bin file from the TFTP server with the IP address (192.168.10.99) on the switch.

A similar example using ftp would be similar to what is shown in Figure 16, except the command ‘mode=tftp’ will be replaced by ‘mode=ftp’. Make sure the username and password for the ftp user is known. If not known, use the user name anonymous with any password. Enter the username and password when prompted by the ftp server. Note – if you are using MNS-6K version3.0 or lower, it is best to use the FTP server without a password – i.e. use the anonymous login.

Next steps

(Optional step) Reload the saved configuration. Update the boot code if needed. This is described in step 4.

Magnum6K25# show version · Magnum6K25# reboot · Magnum6K25# show version

Page 319 of the GarrettCom MNS-6K user manual — Reloading the configuration
Page 319 · click to enlarge
Page 319

U P D A T I N G S O F T W A R E – S T E P 4 Step 4

4. (Optional Step) Restoring the configuration

Optionally, restore back the original configuration and update the boot code…..

t this optional step, the original configuration has been saved, MNS-6K image copied from the www.garrettcom.com site and then onto the Magnum 6K switch and finally, if required, the configuration can be restored using the instructions in this step. If the Magnum 6K switch is updated over the network, it maybe necessary to update the boot code. A

Accessing the switch

Continue to use the access method defined in steps 1, 2 and 3.

Reloading the configuration

The command used for restoring the original configuration is

Syntax loadconf mode=<serial|tftp|ftp> [<ipaddress>] [file=<name>]

mode is the mode by which the configuration file will be accessed for upload – serial, ftp or tftp

ipaddress is the IP address of the ftp or tftp server (only used when mode = ftp or tftp)

file=name is the name of the configuration file

At this stage, follow the same process for uploading the files as described in step 3. The file that needs to be uploaded is the configuration file which was saved in step 2 (as shown in Figure 7 or Figure 12.)

Where

Page 320 of the GarrettCom MNS-6K user manual — Updating boot code over the network
Page 320 · click to enlarge
Page 320

U P D A T I N G S O F T W A R E – S T E P 4

Updating boot code over the network

As discussed in step 1 – selecting the proper version, with either upgrade path (to Version 2.7.1B or to Version 3.0), the boot code will be updated. At boot up time, the Magnum 6K switch identifies that there is a new version of the boot code and asks if the new boot code should be loaded11. The new boot code is not loaded unless the user responds affirmatively to the question from the console port (or serial connection)12. If the Magnum 6K switch is upgraded over the network or remotely, the boot code can be manually updated by using the ‘upgrade’ command discussed below. This allows the boot code to be updated without requiring access to serial port.

mode=bl is a hidden option and is not visible using the help capabilities in MNS-6K. This command can be executed by accessing the switch through the console port (serial connection) or through the network (telnet to the switch.)

Continue to use the network access method defined in steps 1, 2 and 3. Use the upgrade command as shown in Figure 17 and reboot the switch.

Magnum6K25# upgrade mode=bl The BOOT Flash image will be replaced by the version embedded in this application. Do you wish to upgrade the image? [ 'Y' or 'N'] Y Uncompressing image and programming flash memory. This will take up to a minute to complete... Boot loader upgrade is successful... Magnum6K25# reboot

Proceed on rebooting the switch? [ 'Y' or 'N' ] Y

Do you wish to save current configuration? [ 'Y' or 'N' ] Y FIGURE 157 – Updating the boot code over the network using the upgrade command. Make sure to reboot the switch after the boot loader upgrade is completed

11 This question is asked on the console port (serial connection) only.

12 Note – If the response is not given, the switch will not load the new boot code.

Syntax upgrade mode=bl

Page 321 of the GarrettCom MNS-6K user manual — Network Access
Page 321 · click to enlarge
Page 321

U P D A T I N G S O F T W A R E – S T E P 4

Make sure there is no power failure during the boot loader update. If the boot code does not load properly, please contact GarrettCom Inc technical support at (510) 438-9071, email – support@garrettcom.com

Intentionally left blank

Page 326 of the GarrettCom MNS-6K user manual — I N D E X
Page 326 · click to enlarge
Page 326

I N D E X

saveconf, 45, 53, 56, 259

saveconf mode, 56, 259

set-leave, 205, 206, 208, 271

script, 46, 47, 260, 282, 297

setport, 80, 81, 85, 93, 94, 95, 99,

sendmail, 241, 243, 255, 276

set-port, 111, 112, 115, 117, 122,

204, 205, 266, 271

server, 241, 256, 276

setport monitor, 93, 101, 265

setport port, 94, 101, 265

set, 24, 25, 28, 31, 32, 33, 35, 37,

40, 42, 43, 44, 46, 48, 55, 56, 57, 58, 64, 67, 69, 70, 72, 73, 75, 93, 94, 95, 96, 107, 109, 113, 122, 127, 137, 147, 160, 165, 166, 167, 200, 221, 223, 232, 246, 247, 248, 256, 257, 258, 259, 261, 262, 266, 267, 269, 272, 277, 286, 287, 289

set-qi, 205, 206, 208, 272

setqos, 189, 191, 192, 193, 271

set-qri, 205, 207, 208, 272

setsntp, 44, 45, 56, 259

setsntp server, 56, 259

setvar, 42, 55, 222, 226, 232, 247,

set date, 43, 55, 259

set daylight, 43, 56, 259

set-weight, 190, 193, 271

set ftp mode, 46, 48, 56, 248, 256,

show, 19, 27, 31, 32, 36, 38, 39,

41, 42, 43, 46, 48, 54, 56, 57, 58, 61, 62, 63, 66, 67, 68, 69, 70, 71, 72, 74, 75, 80, 81, 82, 85, 90, 93, 94, 95, 97, 98, 99, 100, 101, 102, 108, 109, 110, 112, 113, 114, 116, 117, 122, 124, 127, 128, 129, 130, 131, 132, 133, 134, 138, 139, 140, 141, 143, 144, 145, 146, 147, 148, 160, 161, 162, 165, 166, 167, 181, 184, 185, 191, 192, 193, 194, 202, 203, 205, 206, 207, 213, 215, 221, 222, 223, 226, 228, 231, 232, 234, 237, 239, 240, 242, 243, 245, 246, 248, 249, 254, 256, 259, 261, 262, 263, 265, 266, 267,

set logsize, 72, 73, 75, 262

set password, 61, 62, 63, 64, 262

set prompt, 246, 247, 256, 277,

set serial, 40, 55, 259

set snmp, 221, 223, 232, 272

set stp, 127, 137, 147, 160, 165,

166, 167, 267, 269

set time, 43, 56, 259

set timeformat, 43, 56, 259

set timezone, 43, 55, 259

set vlan, 107, 109, 113, 122, 266

set-forbid, 215, 216, 272

Show 12 more labels / short text on this page
set-ingress, 111 · 101, 263, 265 · serial number, 54 · service, 74 · set-ports, 215, 272 · set-querier, 204, 206 · set-untag, 194, 271 · set bootmode, 37 · 259, 273 · 277, 287 · set igmp, 200 · set-egress, 111
Page 328 of the GarrettCom MNS-6K user manual — TAB, 32, 34, 258
Page 328 · click to enlarge
Page 328

I N D E X

show-forceversion, 142, 144, 148,

s-ring, 160, 165, 166, 167, 269,

show-group, 204, 208, 223, 228,

S-Ring, ii, 20, 149, 150, 151, 152,

154, 156, 157, 158, 159, 160, 161, 162, 163, 164, 166, 186, 268, 279

show-port, 83, 84, 112, 122, 204,

205, 208, 266, 271

s-ring add, 160, 161, 166, 167, 269

show-portweight, 190, 193, 194,

s-ring del, 160, 167, 269

show-router, 204, 205, 208, 271

show-stats, 84, 86, 264

s-ring learn, 160, 166, 269

show-timers, 142, 145, 148, 268

start, 108, 110, 115, 122, 266

show-trap, 222, 227, 233, 273

show-user, 223, 229, 230, 233, 274

static, 213, 215, 272

show-view, 223, 228, 233, 274

statistics, 231, 234, 274

signal, 66, 69, 70, 75, 262

stp, 127, 130, 134, 160, 164, 165,

166, 167, 267, 268, 269

signal port, 66, 75, 262

STP, 20, 51, 53, 80, 95, 98, 99,

smtp, 240, 242, 243, 254, 256,

123, 124, 125, 126, 127, 128, 129, 130, 131, 132, 133, 134, 135, 136, 137, 138, 139, 140, 141, 142, 143, 144, 145, 146, 147, 148, 149, 150, 151, 152, 153, 154, 155, 156, 157, 158, 159, 160, 161, 163, 164, 165, 166, 167, 179, 191, 236, 238, 239, 267, 268, 269, 282, 284, 287, 291, 293, 295, 296

SMTP, 239, 240, 241, 242, 243,

244, 255, 256, 275, 276, 286, 292, 294

snmp, 42, 55, 231, 247, 259, 272

SNMP, 21, 23, 35, 39, 42, 66, 74,

80, 218, 219, 220, 221, 222, 223, 224, 226, 230, 231, 232, 240, 241, 242, 244, 252, 254, 255, 256, 272, 273, 275, 276, 278, 285, 287, 293, 294

stp enable, 127, 130

STP Path cost, 141

supplicant, 77, 79, 80, 81, 85, 86,

SUSTAINED, 235, 236, 237, 238

snmpv3, 222, 226, 232, 272

sync, 44, 45, 56

sntp, 44, 45, 56

TAB, 32, 34, 258

Show 14 more labels / short text on this page
233, 271, 274 · s-ring enable, 160 · start vlan, 110 · show-vlan, 215, 272 · stop, 113 · 275, 276 · SNMP engine, 219 · SNMP group, 219 · 263, 264 · SNMP user, 219 · Supplicant, 77 · SNMPv2c, 218, 219 · sysname, 247 · sntp enable, 45
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the GarrettCom MNS-6K

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom MNS-6K

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom MNS-6K manual PDF

329 pages·4 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…