Installation and User Guidep.1Magnum 3000p.1Stackable Hubsp.1Magnum ™ 3000p.2Phone (510) 438-9071p.3REVISIONSp.4PREFACEp.45.0 INTRO SIMPLE NTWRK MGMT PROTOCOL (SNMP) AGENTS32p.65.1.1 Embedded SNMP Agent, Model 3000-MB.............................. 32p.65.1.2 Separate Agent Box, Model 3000-AGT ................................... 33p.65.1.3 Standard Repeater MIB and Extensions .................................... 33p.65.3 Installing the Embedded Agent Board, "MB"................................... 36p.65.4 Agent Configuration, Embedded Agent and Agent Box Versions ... 39p.65.4.1 Automatic Agent IP Address Configuration............................. 40p.65.4.2 Manual IP Address Configuration. ............................................ 40p.65.4.3 Other Convenience Commands.................................................. 43p.66.3 Return Material Authorization (RMA) Procedure............................. 45p.66.4 Shipping and Packaging Information................................................. 46p.6APPENDIX A: WARRANTY INFORMATION......................................... 46p.6APPENDIX B : INTERNAL DC POWER SUPPLY OPTION................... 47p.6APPENDIX C : INTERNAL DC DUAL-SOURCE POWER OPTION..... 49p.6and Coax Models, All Types - July, 06p.7The “X-line” of configurable Mi X ed Media products:p.7ETHERNET CONNECTIVITY PRODUCTSp.7"DESIGNED AND MANUFACTURED IN THE USA"p.7The Magnum Linep.7OVERVIEWp.7Stackable Hubs, SNMP Optionalp.7Fan-Outs, 10Mb seriesp.71.0 Specifications - Magnum 3024, Magnum 3012p.81.1 Specifications - Repeater Port Modules (RPMs); Bonus Portsp.101.2 Specifications - Bridge Port Modules (BPMs); Bonus Portsp.101.3 Ordering Informationp.112.0 Introduction - Magnum 3012 and 3024 Stackable Hubsp.122.1 Inspecting the Package and Productp.122.2 Product Description - Magnum 3000 Stackable Hubsp.132.3.1 Stacking Magnum 3000sp.142.3.2 Segmenting a Magnum 3000 Stack with a Special Segmentingp.15Cablep.15BEFOREp.16AFTERp.16BRIDGEp.16IRBp.162.3.3 Group # Address Switch Settings, for Managed Units and Stacksp.17OFFp.17ONp.17LINKp.18RXp.18GARRETTp.182.5 Rear Bonus Slot, Port Modules (PMs)p.19Bonus port for optionalp.20PM card (BPM shown)p.20(RPM)p.20J1/Bp.20(AUI)p.20J1p.20NOTE:p.20CBL-AUIp.212.6 Features and Benefits, Magnum 3024 and 3012 Hubsp.22SNMP NMSp.232.7 Applicationsp.2310BASE2p.233.1.5 Connecting Fiber Optic 10BASE-FL and FOIRL (ST-type,p.25“Twist-Lock")p.253.1.8 Power Budget Calculations for Magnum 3000s RPM’s with Fiberp.263.1.7 Connecting Single-Mode Fiber Optic (SMF)p.26Mediap.26BPM-BNC BPM-AUI BPM-TP BPM-FSTp.294.0 Introduction - Magnum Port Modulesp.294.1 Inspecting the Package and Productp.294.2 Product Description, Port Modulesp.294.2.1 RPM-BNCp.304.2.2 RPM-AUIp.30Magnum RPM-AUIp.314.2.3 RPM-DTEp.32NOTES:p.32DEFAULTp.334.2.4 RPM-FST (Fiber ST, Twist-lock Connector)p.33JUMPER ACROSS DISTANCES SUPPORTEDp.334.2.6 RPM-SMF (Single-mode Fiber)p.34
Page 1 of the GarrettCom Magnum 3000 user manual — Installation and User Guide
Page 1 · click to enlarge
Page 1
GarrettCom Magnum 3000 — Installation and User Guide diagram (page 1)
Fig. 1 · Installation and User Guide

Installation and User Guide

Magnum 3000

Stackable Hubs

GarrettCom Magnum 3000 — Installation and User Guide diagram (page 1)
Fig. 2 · Installation and User Guide
Page 2 of the GarrettCom Magnum 3000 user manual — Stackable Hubs
Page 2 · click to enlarge
Page 2

serviceable parts. Attempted service by unauthorized personnel shall render all

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a

Stackable products, consult Section 6, Troubleshooting, of this User Guide.

warranties null and void. If problems are experienced with Magnum 3000

of this publication may be reproduced without prior written permission from

Installation and User Guide

Copyright © 2006 GarrettCom, Inc. All rights reserved. No part

Magnum ™ 3000

Part #84-00060 (Rev. 04/02 )

Stackable Hubs

UL is a registered trademark of Underwriters Laboratories

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

registered trademark of GarrettCom, Inc.

Printed in the United States of America.

GarrettCom, Inc.

Trademarks

Page 3 of the GarrettCom Magnum 3000 user manual — Phone (510) 438-9071
Page 3 · click to enlarge
Page 3

This equipment generates, uses and can radiate frequency energy and if not

installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested and

found to comply with the limits for a Class A computing device in accordance with the

specifications in Subpart J of Part 15 of FCC rules, which are designed to provide

reasonable protection against such interference when operated in a commercial

environment. Operation of this equipment in a residential area is likely to cause

interference, in which case the user at his own expense will be required to take whatever

Please use the mailing address, phone and fax numbers and email address listed below:

Radio Frequency Interference Statement

Websitehttp://www.GarrettCom.com

email support@garrettcom.com

47823 Westinghouse Dr. Fremont, CA 94539-7437

GarrettCom, Inc.

Phone (510) 438-9071

measures may be required to correct the interference.

Federal Communications Commission · Fax (510) 438-9072 · Contacting GarrettCom, Inc

Page 4 of the GarrettCom Magnum 3000 user manual — REVISIONS
Page 4 · click to enlarge
Page 4

Port Modules (BPMs) including features, installation and operation.

SECTION 1 covers the product specifications for Magnum 3000 Stackable

SECTION 3 describes Magnum Repeater Port Modules (RPMs) and Bridge

R9/97This revision includes a safety precaution at the beginning of both Installation

documented (see Sections 3.2.4 and 3.2.5); Installation of PMs for the 3012 and 3024

SECTION 4 describes management options for the Magnum 3000 family;

developed (see Section 2.3.2) which allows 3000s to be physically stacked together

R07/06Updated Rack-mounting and Appendix B & C with 24VDC and 125VDC
R05/02Updated Rack-mounting and Appendix B & C with 24VDC and 125VDC
R03/01Change the company’s name to GarrettCom, Inc.(formerly it was Garrett

Communications). There are no changes made to the content material at this time.

R1/96The following revisions have been made to the Magnum 3000 product line

and controlled by a single SNMP agent, while remaining isolated from each other;

SECTION 5 discusses troubleshooting and warranty procedures for all

R10/98This revision separates the Magnum 3000 hubs manual from the 3000X
R3/97This revision includes a new Appendix A: the 48VDC power option; the

and Users’ Guide since the (02/95) release: An IRB Segmenting Cable has been

Concentrator manual, and revises the appendices covering 48V power options.

SECTION 2 covers the Magnum 3024 and 3012 Stackable Hubs.

previous Appendix A: Warranty Information is now labeled as Appendix B.

The distance jumpers on the Magnum RPM-FST and RPM-FSM have been

R3/99: This revision revises the appendices covering 48V power options.

Hubs family, and also provides ordering information.

the SNMP agents, how they are installed and used.

R07/01-48VDC (OPTIONAL) and Fuse info. added in Specifications

of the Magnum 3000 Stackable Hubs .

R01/02Updated Operating Environment Specifications

Bonus Ports is now documented (see Section 2.5).

This user guide is divided into six main sections:

sections for the 3012 / 3024, and the RPM-FSC

Power Supply Option as per UL instructions.

REVISIONS

PREFACE

Power Supply Option

Page 5 of the GarrettCom Magnum 3000 user manual — REVISIONS
Page 5 · click to enlarge
Page 5
Page 5 of the GarrettCom Magnum 3000 user manual — REVISIONS
Page 6 of the GarrettCom Magnum 3000 user manual — 5.0 INTRO SIMPLE NTWRK MGMT PROTOCOL (SNMP) AGENTS32
Page 6 · click to enlarge
Page 6

5.0 INTRO SIMPLE NTWRK MGMT PROTOCOL (SNMP) AGENTS32

5.1 SNMP Agents Description................................................................. 32

5.1.1 Embedded SNMP Agent, Model 3000-MB.............................. 32

5.1.2 Separate Agent Box, Model 3000-AGT ................................... 33

5.1.3 Standard Repeater MIB and Extensions .................................... 33

5.2 Installation, General Information....................................................... 36

5.3 Installing the Embedded Agent Board, "MB"................................... 36

5.4 Agent Configuration, Embedded Agent and Agent Box Versions ... 39

5.4.1 Automatic Agent IP Address Configuration............................. 40

5.4.2 Manual IP Address Configuration. ............................................ 40

5.4.3 Other Convenience Commands.................................................. 43

6.0 TROUBLESHOOTING ...................................................................... 44

6.1 Before Calling for Assistance ............................................................ 44

6.2 When Calling for Assistance ............................................................. 45

6.3 Return Material Authorization (RMA) Procedure............................. 45

6.4 Shipping and Packaging Information................................................. 46

APPENDIX A: WARRANTY INFORMATION......................................... 46

APPENDIX B : INTERNAL DC POWER SUPPLY OPTION................... 47

APPENDIX C : INTERNAL DC DUAL-SOURCE POWER OPTION..... 49

Page 7 of the GarrettCom Magnum 3000 user manual — "DESIGNED AND MANUFACTURED IN THE USA"
Page 7 · click to enlarge
Page 7

Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports,

4K-Series Switches, 100 & 10Mbps, copper ports with optional fiber port, with auto-negotiating full switching performance

GarrettCom, Inc.offers the premium-quality Magnum™ line of Ethernet LAN

connectivity products with industry-standard functionality and built-in fiber

configurability. Magnum products are designed for use in demanding Carrier Class,

Industrial Grade and OEM applications where reliability is a primary consideration.

“Outdoor” Ethernet Switch, for temperature uncontrolled locations

6 10/100 and 2 100Mb fiber ports, can be connected in strings Mixed-Media Fiber Hub, 16-port Stackable, 10/100 auto-sensing

10Mb series and 100Mb series, both w/ optional port modules Personal Switches, 10/100Mb

8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series

All media combinations, incl. fiber ST, SC, mm., single mode

Repeater Port Modules (RPMs), 6 types for Ethernet media

Bridge Port Modules (BPMs), 4 types, for segment isolation

2, 4 and 8 Port Models Transceivers, 10Mb and 100Mb series 10Mb Mini-Transceivers

and Coax Models, All Types - July, 06

Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing

mixed-speed and mixed-media types, full switching performance

Stackable Concentrators, SNMP optional, 13-Ports

8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb

The “X-line” of configurable Mi X ed Media products:

Mini-Concentrators, 7 Ports, Repeaters, 2-Ports

ETHERNET CONNECTIVITY PRODUCTS

8-port, with two switched ports (1 fiber built in) Personal Hubs, 10Mb series

"DESIGNED AND MANUFACTURED IN THE USA"

The Magnum Line

OVERVIEW

Stackable Hubs, SNMP Optional

Fan-Outs, 10Mb series

Page 8 of the GarrettCom Magnum 3000 user manual — 1.0 Specifications - Magnum 3024, Magnum 3012
Page 8 · click to enlarge
Page 8
Fiber OpticSC (Snap-in Connector, for multi-mode fiber cables only)
Fiber OpticST (Twist-Lock Connector, for single and multi-mode)

10BASE-FL multi-mode Fiber optic - 2 km (6,562 ft)

RJ-45Shielded, 8-Pin Female (Note: Shielded 10BASE-T
Data Rate10 Mbps RPM Partitioning: Enforced after 32 consecutive collisions
RPM ReconnectOccurs after 512 bits error-free reception
Power ConsumptionModel 3024 : 18 watts typical; 30 watts max,
Model 301210 watts typical; 20 watts max,
3000-AGT9 watts typical; 20 watts max,
BPM Auto-Learning Address List256 nodes capacity

10BASE-T (twisted pair) - 100 m (328 ft)

Single-mode Fiber optic - 10 km (32,810 ft)

Ambient Temperature: 25ºF to 120ºF (-5ºC to 50ºC) Storage Temperature: -40ºF to 185ºF (-40ºC to 85ºC)

connectors accept either unshielded or shielded wiring

AC Power ConnectorIEC-type, male recessed, rear of chassis

10BASE5 ThickNet - 500 m (1,640 ft)

FOIRL multi-mode Fiber optic - 1 km (3,281 ft)

BPM Filtering and Forwarding Rate: 14,880 pps max.

DTE (AUI Drop Cable) - 50 m (164 ft)

Shielded twisted pair - 150m (492 ft)

10BASE2 ThinNet (BNC) - 185 m (607 ft)

Ambient Relative Humidity5% to 95% (non-condensing)
Ethernet V1.0/2.0 IEEE 802.310BASE-T, 10BASE5,
AUID-Sub 15-Pin Female (with slide lock)
DTED-Sub 15-Pin Male (with lock posts)

1.0 Specifications - Magnum 3024, Magnum 3012

10BASE2, 10BASE-FL & FOIRL, and DTE

Input Voltage100 - 240 vac (auto-ranging)
Altitude-200 to 13,000 Ft. (-60 to 4000 m)
Input Frequency47 - 63 Hz (auto-ranging)
Conformal coating optionRequest quote

plugs for standard twisted pair media wiring.)

Maximum Ethernet Segment Lengths

ThinNetBNC
Show 5 more labels / short text on this page
Operating Environment · Power Supply (Internal) · Port Connector Types · Network Standards · Performance
Page 9 of the GarrettCom Magnum 3000 user manual — 1.0 Specifications - Magnum 3024, Magnum 3012
Page 9 · click to enlarge
Page 9

3012 and 3024 w/ embedded agent: Fan cooled, internal @ 7cfm

DimensionsModels 3024, 3012, 3000-AGT: 9.0 in x 17.0 in x 1.75 in

LINK - (Models 3024 & 3012) Per RJ-45 port, Steady On when twisted

For Dual Source and Redundant DC for –48VDC, 24VDC Power &

Cooling methodModels 3024, 3012, 3000-AGT: Convection except

RX - (Models 3024 and 3012) Per RJ-45 port, Receive, Green LED,

Three years, return to factory Made in USA

PWR - Power, Green LED, steady on when AC power is applied.

EnclosuresHigh strength sheet metal, suitable for wiring closet
Power Consumptionsame as for AC models, see above

pair link is operational, flashing if the port is partitioned by hardware

125VDC supply options (Optional), see Appendices.

WeightModel 3024: 5.0 lbs (2.3 Kg), Model 3012 and

blinks to indicate activity of data being received on the port.

125VDC Power Input Voltage120 to 300VDC Std. Terminal Block : “ -, GND, + ”
-48VDC Power Input Voltage36 to 72 VDC
24VDC Power Input Voltage20 to 36VDC

shelf, rack or table-top mounting.

(22.9 cm x 43.2 cm x 4.45 cm)

Emissionsmeets FCC Part 15 Class A
OptionalETSI and NEBS L3 Certified

3000-AGT:4.0 lbs (1.8 Kg)

UL Listed (UL 1950), cUL, CE

LED Indicators on Chassis Front

DC Power Supply (Options)

Agency Approvals · Packaging · Warranty

Page 10 of the GarrettCom Magnum 3000 user manual — 1.2 Specifications - Bridge Port Modules (BPMs); Bonus Ports
Page 10 · click to enlarge
Page 10

** Internal termination switch for BNC, no "T" connector is required. *** MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 uplink,

** Internal termination switch for BNC, no "T" connector is required. *** MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 uplink,

Switch on Face Plate yes** n.a. yes***

RPM TypeBNC AUI DTE Fiber-mm Fiber-sgl.m TP*

Connector Type BNC-f DB-15 f DB-15 m Fiber-ST Fiber-ST RJ-45

Front Access yes

Partition (PART)LED yes

Receive (RX) LED yes

LINK LED n.a. n.a. n.a. yes yes yes

* The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring.

* The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded and shielded twisted pair wiring.

“Fiber-mm” is multi-mode cable, normally used for 10BASE-FL installations, up to

1.1 Specifications - Repeater Port Modules (RPMs); Bonus Ports

2.0Km. “Fiber-sgl.m” is single-mode cable, used for distant installations, up to 10.0Km.

1.2 Specifications - Bridge Port Modules (BPMs); Bonus Ports

BPM TypeBNC AUI Fiber TP*

Connector Type BNC(f) DB-15(f) ST RJ-45

Switch on FP yes** n.a. n.a. yes***

FWD-I LED yes

FWD-X LED yes

LINK LED n.a. n.a. yes yes

no crossover cable is required.

no crossover cable is required.

Page 11 of the GarrettCom Magnum 3000 user manual — 1.3 Ordering Information
Page 11 · click to enlarge
Page 11

line items on the same order, in order to specify that the RPM-BNC is to be factory-configured

Magnum RPM-TP Module w/ 1 shielded female RJ-45 connector + up-link switch

** These items must be included to convey configuration information to the factory. For

rear bonus port slot, you must include Model "3024-PM" and Model RPM-BNC as separate

Magnum 3012-NEBS NEBS Level 3 tested and certified with -48VDC power supply

Magnum 3024-NEBS NEBS Level 3 tested and certified with -48VDC power supply

Magnum RPM-AUI Module with 1 AUI (DB-15 female) connector, with slide lock

Magnum RPM-DTE Module with 1 DTE (DB-15 male) connector, with lock posts

Magnum RPM-FST Module w/ mm* Fiber ST “twist” 10BASE-FL dual connector

Magnum BPM-TP Local Bridge Module with 1 RJ-45 connector + uplink switch

example, to order a Model 3024 Hub with a BNC-type RPM option factory installed in the

Magnum 3000-AGT SNMP option, Embedded Agent Box as a separate stack unit

Magnum RPM-BNC Module with 1 BNC connector, internal termination switch

GARRETTCOM, INC.reserves the right to change specifications, performance

Magnum 3024 Base Chassis with 24 RJ-45 ports, shielded connectors

Magnum 3012 Base Chassis with 12 RJ-45 ports, shielded connectors

Magnum 3000-NMS "SNMPc" PC / Windows-based Network Management

Magnum BPM-FST Local Bridge Module with mm* Fiber ST connector

Software product from Castle Rock Computing.

Magnum BPM-BNC Local Bridge Module with 1 BNC connector

Magnum BPM-AUI Local Bridge Module with 1 AUI connector

Magnum RPM-SMF Module w/ single-mode Fiber connector

Magnum 3000-MB SNMP option, Embedded Agent Board

Magnum PM-FP Face Plate - cover for unused front slots

ETSI and NEBS-certified models, -48VDC powered

Base Chassis with 12 RJ-45 ports

Base Chassis with 24 RJ-45 ports

Magnum 3000 Stackable Hubs and Concentrators

characteristics and/or model offerings without notice.

Network Management Options:

1.3 Ordering Information

Port Modules (PMs)**:

* mm = multi-mode.

in the rear bonus port.

Page 12 of the GarrettCom Magnum 3000 user manual — 2.1 Inspecting the Package and Product
Page 12 · click to enlarge
Page 12

product; notify the carrier of any damage which you believe occurred during shipment or

In the event there are items missing or damaged, contact the party from whom

Remove the items from the shipping container. Be sure to keep the shipping

This section describes the features and capabilities of the Magnum 3012 and

delivery. Inspect the contents of this package for any signs of damage and ensure that

container should the unit need to be re-shipped at a later date. To validate the product

shipping container if possible. Refer to Section 6, Troubleshooting, for specific return

3024 Stackable Hubs, including bonus ports, applications, installation, and

Examine the shipping container for obvious damage prior to installing this

you purchased the product. If the unit needs to be returned, please use the original

warranty, please complete and return the enclosed Product Registration Card to

2.0 Introduction - Magnum 3012 and 3024 Stackable Hubs

1. Inter-Repeater Bus (IRB) ribbon cable with connectors
1. Set of metal "Ears" for optional rack mounting
1. AC Power Cord (U.S. and other 115 vac only)
1. Magnum 3012 or Magnum 3024 Base Unit

2.1 Inspecting the Package and Product

3000 units in a managed Magnum 3000 stack.

1. Installation and User Guide
1. Product Registration Card

the items listed below are included.

GarrettCom as soon as possible.

This package should contain:

operation.

procedures.

Page 13 of the GarrettCom Magnum 3000 user manual — 2.2 Product Description - Magnum 3000 Stackable Hubs
Page 13 · click to enlarge
Page 13

enterprises needing an Ethernet local area network, either managed or unmanaged. They

networks built using Magnum 3000 Stackable Hubs are easily expanded by adding units

Magnum 3000 Stackable Hubs are available in two building-block models: the

mounted bonus port may be configured for any media type using a Magnum Port Module

data with the associated port. Each LINK LED is steady ON when that twisted pair link

Magnum 3000 Stackable Hubs are equipped with shielded RJ-45 connectors,

(PM), for applications such as connecting to a backbone up-link and segment isolation.

worldwide, and each unit is normally convection-cooled for silent operation. Magnum

will operate, individually or combined in a stack, as self-sufficient devices to provide

3024, with 24 ports for low cost per port and high port density, and the 3012, with 12

Link/Partition (LINK) and Receive (RX) for each individual port. The LEDs for each

port are located immediately above the port connector for clear coordination of status

is operational, and flashing when that port is partitioned by hardware. Each RX LED

10BASE-T Ethernet connectivity for all local users and devices. Small independent

ports for low entry-level or add-on cost. Both units have an internal power supply, a

metal enclosure for stand-alone or rack mounting, and convenient front access status-

and support full length segments of Ethernet twisted pair media. An additional rear-

Only 1.75 (4.45 cm) high, the compact Magnum 3000 Hubs economize on rack and

repeater functionality to perform signal amplification, re-timing, and regeneration of

preamble bits for each packet received. Consistent with IEEE 802.3 specifications,

The internal power supply is auto-ranging to handle any AC power type

3000 Stackable Hubs operate in compliance with the IEEE 802.3 specification for

Magnum 3000 Stackable Hubs will detect collisions, generate jam signals, extend

Magnum 3000 Stackable Hubs are suitable for small- to medium-size

collision fragments, and automatically partition and re-connect individual ports.

Status-indicator LEDs consist of Power On (PWR) for the unit, and

in a modular (stacking) manner, interconnected via the Inter-Repeater Bus.

2.2 Product Description - Magnum 3000 Stackable Hubs

blinks when packets are received on the port.

indicator LEDs and RJ-45 port connectors.

wiring closet space.

Page 14 of the GarrettCom Magnum 3000 user manual — 2.3.1 Stacking Magnum 3000s
Page 14 · click to enlarge
Page 14
GarrettCom Magnum 3000 — 2.3.1 Stacking Magnum 3000s diagram (page 14)
Fig. 3 · 2.3.1 Stacking Magnum 3000s
GarrettCom Magnum 3000 — 2.3.1 Stacking Magnum 3000s diagram (page 14)
Fig. 4 · 2.3.1 Stacking Magnum 3000s
1. 6 = Address of Repeater Unit (1-20) 7 = Not Used - Previously used to allow PC based SNMP Agent 8 = Not Used

The Magnum 3024 Hub provides 24 RJ-45 ports on the front of the unit plus a

shielded, Category 3 or 4 or 5. The choice of wiring type is left to the installer based on

which is used to daisy chain the IRB to the stacked Magnum 3000 unit below (unused on

chain the IRB to the stacked Magnum 3000 unit above (unused on top unit in a Magnum

The shielded RJ-45 port connectors on the front are electrically connected to

from the unit. (Note that the 10BASE-T wiring cable to the user may be unshielded or

(IRB) connector on the right side. The IRB interconnects stacked units with a shielded

There are two 34-pin IRB connectors on each unit: the bottom IRB connector

bottom unit in a Magnum 3000 stack); and the top IRB connector which is used to daisy

2.3 Magnum 3024 Hub - 24 RJ-45 Ports, One PM bonus port slot

Bonus Port slot on the rear which may be configured with any Magnum Port Module

(PM). User-segment wiring connections are made on the front of the unit, and status-

the metal case of the unit, and are helpful in reducing electromagnetic noise radiation

ribbon cable, enabling all stacked Magnum 3000 units to operate as a single repeater.

The rear of the Magnum 3000 Stackable Hubs have an Inter-Repeater Bus

Steady On LINK LED = Port is Operational

Figure 2.3b, Magnum 3024 (and 3012), Rear View

Figure 2.3a, Magnum 3024 Hub, Front View

3000 stack). The IRB connectors for an non-stacked unit are unused.

indicator LEDs are located immediately above each of the 24 ports.

preferences, standard practices and local or national wiring codes.)

2.3.1 Stacking Magnum 3000s

Page 15 of the GarrettCom Magnum 3000 user manual — Cable
Page 15 · click to enlarge
Page 15

The IRB ribbon cables supplied with each Magnum 3000 base unit are slightly

longer than the base unit height. Thus, an IRB cable segment has a small arc shape when

it is properly installed. It is possible to have some long IRB ribbon cable segments, up to

a few meters in length, for service loops and such. The operation of the stack will not be

meters can be implemented. However, non-standard IRB cable lengths must be specially

The IRB ribbon cables may be installed and/or removed while a Magnum 3000

numbers SRC-2 and SRC-4, available as a spare part from GCI). Hubs connected via an

remove one standard IRB cable and replace it with an SRC cable. This divides the stack

impaired by longer IRB ribbon cables. Stacks with total IRB lengths of as much as ten

2.3.1. However, it may be desirable to stack the 3000s so that they operate as separate

shutting down the network, and for performing diagnostics and service on potentially

faulty units operating in a stack. CAUTION: disconnecting an IRB ribbon cable can

Magnum 3000 Stackable Hubs are typically stacked as described in Section

repeater units. This will normally be done to manage several separate hubs (or small

IRB Segmenting Cable do not transmit or receive normal Ethernet traffic through the

GCI supports this non-standard configuration, making special stacking cable

unit is powered without causing damage to the electronic circuits in that unit or any

2.3.2 Segmenting a Magnum 3000 Stack with a Special Segmenting

several small stacks of units may be connected using SRC Segmenting Cables (part

available (see Models SRC-2 and SRC-4 in the Spare Parts Price List) to provide the

others in a Magnum 3000 stack. This is convenient for expanding a stack without

stacks) with a single 3000 AGT SNMP Agent box. In this situation, single units or

flexibility to break apart managed stacks into multiple collision domains for higher

Consider the case where it is desired to divide a managed stack into two

management. However, using the special Segmenting cable option, it is possible to

cause operational upsets by breaking the interconnection among the stacked units

segments and insert a local bridge to increase performance (see Figure 2.3.2a).

Normally, it would be necessary to add another SNMP agent to maintain full

performance, while still maintaining the advantages of one SNMP agent.

previously operating as a single repeater and/or with one SNMP agent.

Cable

made.

IRB.

Page 16 of the GarrettCom Magnum 3000 user manual — IRB
Page 16 · click to enlarge
Page 16

BEFORE

AFTER

Magnum 3012 units can be used with the special SRC segmenting cable, mixing with the

This special configuration provides high bandwidth for the users on each 3024 hub, but

also provides the efficiency of a single SNMP agent for all of the 3024s. Note also that

Figure 2.3.2bSRC cables segment a managed stack

BRIDGE

for connection to switching hub ports.

IRB

IRB

IRB

agent can manage both repeaters. Then, a local

management data through the SRC so that the

repeaters using a port from each (for example,

collision domains, while still passing SNMP

using a bonus port from each repeater) to

repeaters while maintaining full 10Mbps

bandwidth for the users on each repeater

3024 models in configurations as desired.

into two logical repeaters with separate

bridge can be installed between the two

segmentation using an SRC

The same result could also be

individually segmented and a switching

Bonus Port of one of the repeaters and

stack. Figure 2.3.2a:

Bridge Port Module (BPM) into the

In another example, eight

provide traffic service between the

connecting it to a port on the other

3024 hubs in a managed stack are

achieved by installing a Magnum

hub is used as the traffic center.

repeater.

Show 38 more labels / short text on this page
repeater · repeater · repeater · one · one · one · front rear · front rear · front rear · Magnum 3024 hub · Magnum 3024 hub · Magnum 3024 hub · Magnum 3024 hub · Magnum 3000-AGT · Magnum 3024 hub · Magnum 3024 hub · Magnum 3024 hub · Magnum 3024 hub · Magnum 3000-AGT · Magnum 3024 hub · Magnum 3024 hub · Magnum 3024 hub · Magnum 3024 hub · Magnum 3024 hub · Magnum 3024 hub · Magnum 3024 hub · Magnum 3024 hub · Magnum 3000-AGT · Switching hub · cables · special · SRC cable · SRC cables · cables · special · cable · Stack · cable
Page 17 of the GarrettCom Magnum 3000 user manual — OFF
Page 17 · click to enlarge
Page 17

2.3.3 Group # Address Switch Settings, for Managed Units and Stacks

The eight-position DIP switch on the rear panel is used to give each unit in a

follows the SNMP definition. (Group # addresses and the associated switch settings do

not matter if the units are unmanaged or "dumb"). See the illustration in Figure 2.3.3a.

number from 1 to 20. The switch positions may be moved using an instrument such as a

small screw driver, a pencil eraser or a fingernail. See Section 5.3 for a table of switch

the particular installation. The factory default address switch setting is usually "1", i.e.,

The units in a managed stack should have Group # addresses beginning at 1

and proceeding up to the number of stacked units configured as one logical repeater at

Switches one through six are set at the time of installation to form a binary

Magnum 3000 managed stack a unique Group # or "stack address". This Group #

ribbon cable for the SRC. The standard IRB cables are gray in color.

Figure 2.3.3a, Group # Address Switches, Enlarged Illustration

1 2 3 4 5 6 7 8

Group # ADDRESS SWITCHES

switch 1 ON and switches 2 through 6 OFF.

settings vs. Group # address numbers.

OFF

ON

Page 18 of the GarrettCom Magnum 3000 user manual — GARRETT
Page 18 · click to enlarge
Page 18

If a network management software package is in use, the Group # addresses set

for each Magnum 3000 physical unit will be reflected in the NMS displays, statistics and

addresses will not prevent the units in a stack from working properly in the network, such

optional 3000-AGT unit, which could be the 21st box in a large stack). The stacked units

Group # addresses of zero and from 21 to 31 are not recognized by the NMS software in

The "P1" DB-9 connector on the upper part of the rear panel is used for a serial

port into the optional embedded SNMP agent board. If there is no embedded agent board

in a unit, "P1" is not present. See Section 5.1 for operational information on the optional

The Group # switch settings must not be the same for any two Magnum 3000

units operating in one managed stack. Factory default switch settings cannot be relied

controls that correspond to that unit's Group # address. (While non-sequential Group #

may be any combination of Magnum 3024s, 3012s,3000X and they may be arranged in

any order, physically and logically, for Group numbering purposes. Switch settings for

versions of the product line it allowed the use of a PC-based SNMP AGENT. Switch 8

upon, and the user must check and/or change the Group # address switch settings for

A Magnum 3000 stack may have from 2 to 20 active units (not including an

The Magnum 3012 Hub provides 12 shielded RJ-45 ports on the front of the

2.4 Magnum 3012 Hub - 12 RJ-45 Ports, One PM bonus port slot

unit, and is otherwise like the Model 3024 described above. Refer to the descriptive

Steady On LINK LED = Port is Operational

Switch 7 of the eight-position DIP switch is no longer used. In previous

Flashing LINK LED = Port is Partitioned

numbering tends to create problems for network administration and are therefore

Flashing RX LED = Port Activity

a managed system, and the use of such Group # addresses is discouraged.

Figure 2.4a, Magnum 3012 Hub, Front View

LINK

RX

of the eight-position DIP switch is also unused.

each managed Magnum 3000 unit installed.

Twelve RJ-45 10BASE-T Ports

for each RJ-45 10BASE-T port.

SNMP embedded agent board.

material in Section 2.3 above.

Two LEDs (RX & LINK)

discouraged accordingly.)

GARRETT

Stackable Hub · Magnum 3000

Page 19 of the GarrettCom Magnum 3000 user manual — 2.5 Rear Bonus Slot, Port Modules (PMs)
Page 19 · click to enlarge
Page 19

Magnum 3000s - up to 20 units! - provides essentially unlimited expansion of the number

The Magnum 3012s and 3024s are each equipped with a bonus slot on the rear

six Repeater Port Modules (RPMs) or four Bridge Port Modules (BPMs) to implement an

STP). The BPMs support any of four media types: BNC, AUI, ST, and RJ-45 (UTP and

provide an economical method of adding ports. Note that the high degree of stacking of

of the unit. This slot may be optionally configured at the time of order with any one of

support any of six different media types: BNC (ThinNet), AUI (ThickNet), DTE (male

assortment of standard network connector types for each RPM is shown in Figure 2.5a.

There is no upgrade from a Model 3012 to a Model 3024 since it would not

extra port. The optional bonus port may be used for any purpose, such as an Ethernet

information and specifications of individual PMs, see Section 4 of this manual.) The

AUI), ST & SC (multi-mode Fiber), SMF (single-mode Fiber), and RJ-45 (UTP and

Each PM is equipped with its own media connector type. (For additional

coax backbone connection, or as a micro-bridge segment isolation unit. The RPMs

Figure 2.5aMagnum RPM Modules for Bonus Ports
Left to right aboveRPM-BNC, RPM-AUI (female) ,

RPM-DTE (male), RPM-FST, RPM-FSC, RPM-TP

STP). Normally, a maximum of one BPM should be used in a stack.

2.5 Rear Bonus Slot, Port Modules (PMs)

of users by adding more units to the stack.

Page 20 of the GarrettCom Magnum 3000 user manual — NOTE:
Page 20 · click to enlarge
Page 20
GarrettCom Magnum 3000 — Bonus port for optional diagram (page 20)
Fig. 5 · Bonus port for optional

implemented at the factory as an AUI connector with a ribbon cable to header pins on the

factory configuration at the time of order. It is also possible for the Bonus Port slot to be

have a Port Module connector cable (part number PM-CBL available as a spare part from

Figures 2.5a and 2.5b show the internal layout of the Magnum 3012 and 3024,

May be ordered separately as part #CBL-PM

respectively. When installing a PM into the Bonus Port slot of the Magnum 3012, the

16-pin header labeled J1/B (also labeled RPM) should be used. The red stripe of the

(Included only when PM is factory installed

For application flexibility, any of the Magnum PMs may be specified for

Figure 2.5cMagnum 3012 internal layout with configured Bonus Port
(NoteWhen an RPM-AUI type is configured as a bonus port, it is typically

The family of standard connector types for BPMs is shown in Figure 2.5b.

main board. The functionality is the same as the RPM-AUI card.)

Bonus port for optional

GCI) in addition to the desired PM. See Figure 2.5a and 2.5b.

PM card (BPM shown)

PM connector cable should connect to pin 1of header J1/B.

configured in the field by a trained technician.

(RPM)

Use J1 (AUI) and for Basic AUI ports

J1/B

(AUI)

J1

Use J1/B (RPM) for PMs

NOTE:

Page 21 of the GarrettCom Magnum 3000 user manual — NOTE:
Page 21 · click to enlarge
Page 21

16-pin header labeled P1 (also labeled RPM) on the circuit board corresponding to ports

When installing a PM into the Bonus Port slot of the Magnum 3024, use the

When the RPM-AUI is factory configured as a bonus port, it is implemented

13-24. The red stripe of the connector cable should connect to pin 1 of header P1.

is identical to the RPM-AUI. GCI recommends that RPM-AUI units should not get

Figure 2.5dMagnum 3024 internal layout with configured Bonus Port

corresponding to ports 1-12. However, this is not advised, as the port will not be

PM Ribbon cable with 16 pin connector.

GarrettCom Magnum 3000 — CBL-AUI diagram (page 21)
Fig. 6

May be ordered separately as part # CBL-PM)

(Included only when PM is factory

installed in the bonus port of both 3012’s and 3024’s.

Bonus port for optional

PM card (BPM shown)

CBL-AUI

recognized by an SNMP Agent (if one is present).

connector with a ribbon cable, to

figure 2.5a and 2.5b). Since the

the main board, using CBL-AUI

Use J1 (AUI) and for Basic AUI ports

the 16-pin header J1 (AUI) on

the main board (Shown in both

AUI functionality is build onto

with CBL-AUI, an AUI

Use P1 (RPM) for PMs

NOTE:

CBL-AUI

Pin 1 (red)

Page 22 of the GarrettCom Magnum 3000 user manual — 2.6 Features and Benefits, Magnum 3024 and 3012 Hubs
Page 22 · click to enlarge
Page 22

„ 24 Port and 12 Port "Building Block" Hub Models The 24 port units provide high density and low cost-per-port. The 12 port

units provide minimum add-on and entry-level system cost. The two units

board mounted inside of a 3024 or 3012, or as a separate unit which is the

bridge module capable of filtering and forwarding packets at full Ethernet

as all of the nodes connected to a stack) having significant local inter-node

„ Rack-mount or Table-top, Front-access Connectors and Status LEDs

Thousands of Magnum 3012 and 3024 Stackable Hubs have been installed

Stack. One SNMP agent serves all the Magnum 3000 units in one stack.

Up to twenty Magnum 3000 units may be stacked, thus supporting up to

500 Ethernet segments operating as a single repeater. Both Hubs and an SNMP Agent Box may easily be added to the stack for expansion of the

An optional rear-mounted bonus port may be configured with an RPM of

wire speed. A BPM may be used to bridge-isolate a local segment (such

flexibility. Magnum 3000 Hubs may be mounted in a standard RETMA

At only 1.75 inches (4.45 cm) high, Magnum 3024 and 3012 Hubs save

demonstrated exceptionally low failure rates. Calculated MTBF is up to

The Magnum 3000 Stackable Hubs can be optionally configured with a

BPM as the bonus port. BPMs contain a miniature, self-learning local

associated LEDs are adjacent to each other on the front of the units for

140,000 hours, depending on specific configuration and methodology.

Magnum 3000 Stackable Hubs may optionally be configured with an

SNMP agent. The SNMP agent is available as an embedded daughter

same physical size as a 3024 or 3012 unit and which supports a 3000

any media type, providing flexible connectivity to backbones or other

Match the installation requirements of any environment with stacking

rack or stacked on a shelf or table-top. The 10BASE-T ports and the

system. This provides for low initial cost and for graceful growth of

in critical applications world-wide for multiple years, and have

rack space and provide high port density in the wiring closet.

2.6 Features and Benefits, Magnum 3024 and 3012 Hubs

traffic, thus boosting overall network performance.

„ Bonus Ports for any Ethernet Media Type

may be combined and mixed in one stack.

„ Stackable and Scaleable Configurations

„ Optional Bridge Port Modules

„ Optional SNMP Management

convenient status monitoring.

„ Small, compact units, 1 U

devices and nodes.

network systems.

„ Proven reliability

Page 23 of the GarrettCom Magnum 3000 user manual — 2.7 Applications
Page 23 · click to enlarge
Page 23

solution to a variety of Ethernet networking applications. The combination of Stackable

building, illustrates some of the capabilities. The task was to economically network two

users in Wing C. The optional future SNMP-based network manager can be connected to

Also note that BPMs in the bonus ports at Wings B and C can bridge-isolate this network

Here, a Magnum 3024 hub for 18 UNIX users in Wing B is being used to add

to and to support a ThinNet (10BASE2) segment. The BNC port is implemented via an

(10BASE-FL) cable provides a link from the Wing A Magnum stack to an additional 22

small-to-medium-sized Ethernet networks where reliability and economy are required.

3024's and one Magnum 3012 for 56 PC users in Wing A. A second segment of Fiber

any unit of the Magnum stack in Wing A. (A single SNMP agent may be added to the

physical layer connectivity and for network management, they are popular choices for

Hubs and Stackable Mixed-Media Concentrators with optional SNMP is unique and

workgroups of PCs in Wing A and Wing C, and to consolidate them with an existing

Wing A stack as a future enhancement, for use with network management software.

The Magnum 3000 Stackable Hubs provide a flexible and cost-effective

RPM-BNC in the rear bonus port. This hub is connected to a stack of two Magnum

Because the high quality Magnum 3000s adhere to industry standards for

SNMP NMS

Figure 2.7, taken from an installation in a small educational institution

Figure 2.7Magnum 3000s Consolidate an Educational Network System

into 3 segments, each with essentially full bandwidth for high performance).

22 PC users via UTP.

(2) Magnum 3024’s & (1) Magnum 3012

stacked, for 56 PC users via UTP.

group of UNIX workstation users in Wing B.

2.7 Applications

10BASE2

18 UNIX workstations via AUI and BNC

powerful.

Show 8 more labels / short text on this page
Optional future · 10BASE-FL Fiber Segment · Magnum 3024 for · Wing C · Wing A · ThinNet · Magnum 3024 for · Wing B
Page 24 of the GarrettCom Magnum 3000 user manual — SNMP NMS
Page 24 · click to enlarge
Page 24
2. If the equipment is mounted in an enclosed or multiple rack assembly, adequate air flow must be maintained for proper and safe operation.
2. Connect the other end of the cable to the corresponding device. 3. When proper connection and power have been established, the port’s LINK LED will illuminate GREEN.

over connectors. Set the slide switch to the “down” position for normal twisted

repeater or hub in the network. Verify proper switch position by noting that the

4. If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent overloading of the building/s electrical circuits.

media types via the Bonus Port options. There is a family of Port Modules (PMs). The

The following procedure describes how to connect a 10BASE-T twisted pair

segment to the RJ-45 port on the front panel of the 3000 hub or to the RPM-TP or BPM-

1. Using standard 10BASE-T media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector. Note that, even though the TP connector is

switch to accommodate repeater-to-repeater connections without special cross-

3. If the equipment is mounted in an enclosed or multiple rack system placement of the equipment must not overload or load unevenly the rack system.
5. If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised earthing path.

pair cable segments from the hub port to a user device. Set the slide switch to

1. If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment must be less than or equal to 50 ° C.
7. This equipment is for installation only in a Restricted Access Location (dedicated equipment room service closet and the like) in accordance with the National Electrical

The Magnum 30000 Hubs are specifically designed to support all Ethernet

shielded, either unshielded or shielded 10BASE-T cables and wiring may be

TP of the 3000X or bonus port. The procedure is the same for both unshielded and

the “up” position for cascaded or up-link segment connections to another

6. If the intra-building wiring (cabling) is involved with this product(NEBS), then it is recommended to have shielded cable and the shield is grounded at both ends.

3.0 Installation and Operation Before installing the equipment, it is necessary to take the following precautions:

3.1.1 Connecting Twisted Pair (RJ-45, Unshielded or Shielded)

port’s LINK LED will illuminate when proper link is established.

procedures for connecting each media and connector type are as follows:

3.1 Connecting Ethernet Media

shielded twisted pair segments.

used.

Code.

Page 25 of the GarrettCom Magnum 3000 user manual — “Twist-Lock")
Page 25 · click to enlarge
Page 25

connection. The PM-BNC port is specially equipped with an internal termination switch

on the front of the card (see Section 4.1 for a description of this switch). This eliminates

the need to use a "tee" connector when the BNC cable is ending at the connection to this

1. Plug the cable’s female end into the male DTE connector on the RPM-DTE card. 2. Engage AUI connector slide lock (on the cable) to insure maximum connectivity. 3. Connect the opposite end of the cable into a network AUI port. (This could be a server, router, bridge, hub, or UNIX workstation.)

The following procedure applies to FOIRL and 10BASE-FL applications

1. Plug the cable’s male end into the female AUI connector on the PM-AUI card. 2. Engage the AUI connector slide lock to insure maximum connectivity. 3. Connect the opposite end of the cable into a network AUI port. (This could be a network backbone transceiver, a hub or fan-out with an AUI port, or an AUI Port

Connect the ThinNet coax cable to the BNC connector on the Magnum RPM-

Using the steps below as a guide, attach the 10BASE5 drop-cable directly to the

maximum distance allowed. 10BASE-FL is used for a fiber segment length

of up to 2000m, while FOIRL is used for fiber segments of up to 1000m in

Using the steps below as a guide, attach a new or existing 10BASE5 ThickNet

The AUI port may also used for connecting to other Ethernet devices using

using an RPM-ST or BPM-ST card with ST-type fiber connectors. (The

standard AUI cabling. In this type of situation, it is important to consider the AUI

PM. Some applications may require a "tee" connector, used as a tap, to allow the

3.1.5 Connecting Fiber Optic 10BASE-FL and FOIRL (ST-type,

drop-cable directly to the AUI connector on the RPM-AUI or BPM-AUI port.

primary difference between FOIRL and 10BASE-FL for users is the

segment length to the attached device, including any cascading. See “Product

BNC or BPM-BNC card in the same manner as is done for any standard BNC

10BASE2 coax segment to continue on past the PM-BNC connection.

3.1.4 Connecting Drop Cable 10BASE5 (DTE)

3.1.2 Connecting ThickNet 10BASE5 (AUI)

3.1.3 Connecting ThinNet 10BASE2 (BNC)

Description, RPM-AUI” for additional details.

DTE connector on the RPM-DTE port.

Module in a concentrator.)

“Twist-Lock")

length.)

Page 26 of the GarrettCom Magnum 3000 user manual — Media
Page 26 · click to enlarge
Page 26
2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue
1. Before connecting the fiber optic cable, remove the protective dust caps from the
4. Connect the Receive (RX) port (dark colored post) on the PM-FST to the (TX) Transmit port of the remote device. Use the non-color coded fiber strand for this.

When using the RPM-SMF, be sure to use single-mode (small diameter) fiber

cable. The same five-step procedure as for multi-mode ST-type applies to single-mode.

3.1.8 Power Budget Calculations for Magnum 3000s RPM’s with Fiber

3. Connect the Transmit (TX) port (light colored post) on the Magnum PM-FST to the Receive (RX) port of the remote device. Begin with the color-coded strand

10BASE-FL applications using an RPM-SC card used with SC-type fiber connectors.

Receiver Sensitivity and Transmitter Power are the parameters necessary to

cable polarity. Swap the fiber cables at the Port Module connector to remedy

When connecting fiber media to SC connectors, simply snap on the square

dampened in alcohol. Make certain the connectors are clean before connecting.

5. The LINK LED on the front of the PM-FST will illuminate when a proper connection has been established at both ends (and when power is ON in the

unit). If LINK is not lit after cable connection, the normal cause is improper

The same five-step procedure as for fiber ST-type applies to FOIRL and

compute the power budget. To calculate the power budget of different fiber media

where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,

male connector into the SC female jack of the device until it clicks and secures.

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

at regular intervals; you must use the color-coded strand on the

installations using Magnum products, the following equations should be used:

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

associated ports at each end of the fiber optic segment.

3.1.6 Connecting Fiber Optic (SC-type, "Snap-On")

3.1.7 Connecting Single-Mode Fiber Optic (SMF)

Follow the five steps as described in the Section 3.3.5 above.

of the cable for this first TX-to-RX connection.

OPB (Optical Power Budget) = PT(min) - PR(min)

this situation.

Media

Page 27 of the GarrettCom Magnum 3000 user manual — GARRETT
Page 27 · click to enlarge
Page 27
GarrettCom Magnum 3000 — 3.1.8 Power Budget Calculations for Magnum 3000s RPM’s with Fiber diagram (page 27)
Fig. 7 · 3.1.8 Power Budget Calculations for Magnum 3000s RPM…

Siemens’) web sites and catalogs to provide guidance to network designers and installers.

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only

mode 10 (5) 1300 9/125 -30 -39 7 14 13 26

  • The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the
  • The worst-case OPB of the fiber link must be greater than the fiber cable’s

3.1.9 Rack-mounting Installation of a Magnum 3000s Hub in a 19” rack is a simple procedure. The

industry where they are a standard for Central Office Rack-mounting purposes. The 23”

brackets are mainly used for larger equipment assemblies in rack mounting frames, and

full-duplex (factory default) setting for 100Mbps fiber ports must be used,

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

indicators should be in plain view and easy to read. Rack-mount installation requires

The 23” brackets and ETSI brackets are also available (optional) for Rack-

units are 1U (1.70”) high. When properly installed, the front-mounted LED status

mounting of Magnum 3000 units. The 23” brackets are more popular in the Telco

The following data has been collected from component manufacturer’s (HP’s and

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

which is then fastened into a standard 19” RETMA rack.

are frequently accessed in operation from both sides.

if the following factors are both applied:

Magnum 3000 Stackable Hub

GARRETT

passive Attenuation.

unit). The brackets attach to

(included with each 3000s

the front sides of the Hub,

special 19” rack-mounted · brackets and screws · and

Page 28 of the GarrettCom Magnum 3000 user manual — 3.1.8 Power Budget Calculations for Magnum 3000s RPM’s with Fiber
Page 28 · click to enlarge
Page 28

A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the

environment compatible with the maximum ambient temperature (Tma) specified by the

equipment to the supply circuit and the effect that overloading of the circuits might have

maintained. Particular attention should be given to supply connections other than direct

B) Reduced Air Flow - Installation of the equipment in a rack should be such that the

amount of air flow required for safe operation of the equipment is not compromised.

C) Mechanical Loading - Mounting of the equipment in the rack should be such that a

on overcurrent protection and supply wiring. Appropriate consideration of equipment

Fig 3.1 Multiple Magnum 3000 units rack-mounted in a 23” Rack-mount frame

The ETSI (European Telephone Standard) brackets are similar to the 19”

GarrettCom Magnum 3000 — 3.1.8 Power Budget Calculations for Magnum 3000s RPM’s with Fiber diagram (page 28)
Fig. 8 · 3.1.8 Power Budget Calculations for Magnum 3000s RPM…

ambient. Therefore, consideration should be given to installing the equipment in an

operating ambient temperature of the rack environment may be greater than room

D) Circuit Overloading - Consideration should be given to the connection of the

E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be

hazardous condition is not achieved due to uneven mechanical loading.

The following instructions need to be follow up before installations-

nameplate ratings should be used when addressing this concern.

connections to the branch circuit (e.g. use of power strips)."

metric dimensions.

come as a pair in a

Magnum Hub unit.

manufacturer.

Show 11 more labels / short text on this page
package along with · brackets but use · brackets and the · The · ETSI brackets · brackets to the · optional 23” · the necessary · attaching the · screws for · sides of the
Page 29 of the GarrettCom Magnum 3000 user manual — 4.0 Introduction - Magnum Port Modules
Page 29 · click to enlarge
Page 29

notify the carrier of any damage which you believe occurred during shipment or delivery.

PMs are compact interface cards designed to support every standard Ethernet media type.

need to return the unit, use the original shipping container if possible. Refer to Chapter 5

This section applies only to PMs shipped as separate items, i.e., only to PMs

Examine the shipping container for obvious damage prior to installing a PM;

Remove the PM(s) from the shipping container. Be sure to keep the shipping

In the event there are items missing or damaged contact your supplier. If you

connector type and media. There are a total of six Repeater Port Module (RPM) cards,

Inspect the contents of this package for any signs of damage and ensure that the items

individual Port Modules (PMs) for flexible mixed-media connectivity. The Magnum

Each PM provides one port for connecting one Ethernet segment with its individual

RPM-BNC, RPM-AUI, RPM-DTE RPM-FST (or FSC), RPM-SMF, RPM-TP

An important feature of the Magnum 3000 Stackable Hubs is the use of

BPM-BNC BPM-AUI BPM-TP BPM-FST

This chapter describes each Port Module (PM), including appearance,

container should you need to ship any of the PMs separately at a later date.

not factory installed in a Magnum 3000 Stackable Hubs bonus port slot.

There are also four different Bridge Port Module (BPM) cards. They are:

4.0 Introduction - Magnum Port Modules

4.1 Inspecting the Package and Product

4.2 Product Description, Port Modules

One or more PMs.

Each PM is individually described as follows.

This package should contain:

functionality, and status displays.

for specific return procedures.

plus a face plate. They are:

listed below are included.

Page 30 of the GarrettCom Magnum 3000 user manual — 4.2.2 RPM-AUI
Page 30 · click to enlarge
Page 30

"UP" (or left-side) position, the BNC port requires a "tee" connector (not supplied) and a

terminator. To take advantage of internal termination, the slide switch should be in the

The RPM-BNC module includes one partition (PART) and one receive (RX)

10BASE2 coax connector. This RPM performs full IEEE 802.3 repeater functionality

The RPM-BNC module is designed with a special switch-selectable internal

connector, used as a tap, to allow the 10BASE2 coax segment to continue on past the

LED, which are visible beside the connector. The PART LED illuminates AMBER to

attached to the BNC port where it is internally terminated. When the switch is in the

50 ohm terminator for proper termination. Certain applications may require a "tee"

The Magnum RPM-BNC repeater module is equipped with a standard

and is used for 10BASE2 ThinNet (commonly referred to as BNC) connections.

termination function that eliminates the need for a "tee" connector and a 50 ohm

"DOWN" (or right-side) position. In this configuration, the 10BASE2 segment is

Slide Switch Standard BNC

DOWN (or right) = Internally Terminated, UP (or left) = "T" Connector required.

intermittently to indicate data is being received.

RPM-BNC connection.

established. The RX LED

indicate that the segment

4.2.1 RPM-BNC

partitioned. As soon as

4.2.2 RPM-AUI

the segment will be

Show 9 more labels / short text on this page
Partition LED · Receive LED · Internal Termination · 10BASE2 Connector · directly Magnum RPM-BNC · normal reception resumes, · has been automatically · illuminates GREEN · automatically re-
Page 31 of the GarrettCom Magnum 3000 user manual — Magnum RPM-AUI
Page 31 · click to enlarge
Page 31

to provide connectivity to any media type. The Magnum RPM-AUI card is also used for

connecting Ethernet devices using standard AUI cabling. In this situation, it is important

to consider the AUI segment length or distance to the attached device (see details below).

The maximum transmission distance between a backbone transceiver equipped

AUI connector and the attached device (Magnum RPM-AUI) is 50m (165 ft.). The AUI

segment maximum length is reduced in cascaded configurations. See the following note.

female AUI, Partition LED

with an AUI connector and an RPM-AUI port will vary. When an AUI cable is used to

connect the Magnum RPM-AUI directly to a backbone transceiver, the maximum AUI

segment length is allowed. If the RPM-AUI is connected to a transceiver that has been

According to Ethernet standards, the maximum distance from the transceiver

The RPM-AUI is equipped with a 15 pin female AUI connector and a slide-

RPM-AUI cards are equipped with Partition (PART) and Receive (RX) LEDs which

(20 ft.) for every additional level of network transceiver device "dropped"

cascaded from another transceiver, the maximum AUI segment length is reduced.

lock, and performs full IEEE 802.3 repeater functionality. It is used to provide

Magnum RPM-AUI

implemented as an AUI connector with a ribbon cable to special pins on

the main board. The functionality of this is identical to the RPM-AUI.

function the same as the identical LEDs on the RPM-BNC (see above).

or "cascaded" from the original backbone transceiver tap.

variety of different mini-transceivers

(ThickNet) backbone or to any AUI

segments. A transceiver is required

segment and the RPM-AUI supports

this convention. The RPM-AUI is

interface as it may be used with a

also a "universal" Ethernet media

when connecting to a ThickNet

connectivity with a 10BASE5

Receive LED · Standard 15-pin · with slide-lock

Page 32 of the GarrettCom Magnum 3000 user manual — 4.2.3 RPM-DTE
Page 32 · click to enlarge
Page 32

any device that is equipped with an AUI port. Examples of such devices include servers,

1. Voltage Plus (pin #13) and Voltage Common (pin # 6) use a single

2 Control In Circuit A 11 Data Out Circuit Shield

6 Voltage Common 15 Control Out Circuit B

The Magnum RPM-DTE is a module equipped with a 15-pin male DTE

The RPM-AUI connector supports standard IEEE signals, as follows:

1 Control In Circuit Shield 10 Data Out Circuit B

3 Data Out Circuit A 12 Data In Circuit B

7 Control Out Circuit A SHELL Protective Ground

4 Data In Circuit Shield 13 Voltage Plus (+)

5 Data In Circuit A 14 Voltage Shield

connections (no transceiver Magnum RPM-DTE

Pin Function Pin Function

2. Pins 4, 8, 11 and 14 may be connected to pin #1.

8 Control Out Circuit Shield (conductive shell)

Table 3.2.2AUI Pin Assignments

router, bridges, hubs, and UNIX workstations.

9 Control In Circuit B

twisted pair in the AUI cable.

the two are the same). The RPM-DTE

connector with lock posts. (The RPM-

RPM- AUI which has a 15-pin female

required) using AUI drop cables to

DTE is a mating connector for the

connector and slide locks. The pin

card is designed to support direct

4.2.3 RPM-DTE

NOTES:

Show 5 more labels / short text on this page
Standard 15-pin · male "AUI" · Partition LED · Receive LED · assignments of
Page 33 of the GarrettCom Magnum 3000 user manual — 4.2.4 RPM-FST (Fiber ST, Twist-lock Connector)
Page 33 · click to enlarge
Page 33
GarrettCom Magnum 3000 — DEFAULT diagram (page 33)
Fig. 9

functionality and does not require an external transceiver device. In addition to Partition

intensity of the transmitted signal. By default, the jumper is placed across pins 1 and 2.

The Magnum RPM-FST is a multi-mode fiber optic module equipped with a

(PART) and Receive (RX) LEDs, a LINK LED indicates proper connectivity with the

DEFAULT

remote device.

J1

The jumper may be set as follows to accommodate distances of up to 4 km:

4.2.4 RPM-FST (Fiber ST, Twist-lock Connector)

JUMPER ACROSS DISTANCES SUPPORTED

1. 2 0 - 2 km 3 - 4 0.5 - 3 km* 5 - 6 1.5 - 4 km*

dual ST-type connector. It functions as

segments. When used for 10BASE-FL

supports fiber segments of up to 1000m

an IEEE 802.3 full repeater to support

in length. The RPM-FST includes full

segments, this module supports fiber

2000m. For FOIRL applications, it

10BASE-FL and FOIRL network

optic transmission distances up to

should be placed across pins 1

When distances of less than 2

length must also be increased,

*When fiber cable distances of more than 2 km are

selected, the minimum cable

as shown in the table above.

km are needed, the jumper

and 2.

transceiver Magnum RPM-FST

Page 34 of the GarrettCom Magnum 3000 user manual — 4.2.6 RPM-SMF (Single-mode Fiber)
Page 34 · click to enlarge
Page 34

1 LINK Partition Receive 2 3

The Magnum RPM-SMF is a single-mode fiber optic module equipped with a

additional indicator, a multi-mode TX port emits light (red in color) that is in the visible

spectrum and which can be seen by looking into the port with the power on and with no

cable has a smaller diameter than multi-mode fiber cable (2/15 - 8/60 microns for single-

mode, 50/125 or 62.5/125 microns for multi-mode, where xx/xx are the diameters of the

an SC-type "snap-in" connector instead of an ST-type "twist-lock" connector. Please

cable connected. The single-mode TX port emits light outside of the visible spectrum

The Magnum RPM-FSC is also a multi-mode fiber optic repeater module,

RPM-FST, the label “Sgl. M.” is at the top of the faceplate of the RPM-SMF. As an

dual ST-type connector. It functions as a full repeater to support single-mode fiber

10BASE-FL, FOIRL SC Connectors

the single-mode RPM-SMF from the multi-mode Magnum RPM-SMF

4.2.5 RPM-FSC (Fiber SC, Snap-in Connector)

modules is the same, the RPM-FSC is equipped with

indicating port partitioned (PART), receive activity

(RX), and link operational (LINK). It has the same

4.2.6 RPM-SMF (Single-mode Fiber)

While the functionality of the these two

core and the core plus the cladding respectively).

similar to the RPM-FST. It has the same LEDs

and will always look dark to the human eye.

jumper settings for extra distance in certain

networks. The RPM-SMF supports fiber

PART, RX, and LINK LEDs identical to

optic transmission distances of up to 10

This module is equipped with

those of the RPM-FST. To distinguish

transceiver functionality and does not

require an external transceiver device.

Km. The RPM-SMF includes full

refer to Section 3.2.4. for details.

circumstances.

Magnum RPM-FSC · ST Connectors · Single-mode

Page 35 of the GarrettCom Magnum 3000 user manual — SUPPORTED
Page 35 · click to enlarge
Page 35

environments with maximum segment distances up to 100m (325 ft.), or shielded twisted

With the switch in the UP position, the RPM-TP port is used for cascaded and

pair wiring (STP) of 150m (500 ft.). This module is designed with internal transceiver

The Magnum RPM-TP card supports Ethernet twisted pair segments of any

standard length. It is equipped with a single RJ-45 connector. The RJ-45 connector is

The RPM-TP will support 10BASE-T unshielded twisted pair wiring (UTP)

GarrettCom Magnum 3000 — 4.2.6 RPM-SMF (Single-mode Fiber) diagram (page 35)
Fig. 10 · 4.2.6 RPM-SMF (Single-mode Fiber)

Interface-Crossover (MDI-X) slide switch to allow for cascaded connections. This

GarrettCom Magnum 3000 — 4.2.6 RPM-SMF (Single-mode Fiber) diagram (page 35)
Fig. 11 · 4.2.6 RPM-SMF (Single-mode Fiber)

up-link connections (i.e.: a connection to another repeater or hub or concentrator

typically.) When used for segments going to workstations and other user device

The RPM-TP module is also equipped with a Media Dependent

the jumper is only to be placed across pins 5 & 6. The others are not used.

feature eliminates the need for a special twisted pair crossover cable.

connections, the MDI-X switch should be in the DOWN position.

functionality. The RPM-FST has LINK, PART, and RX LEDs.

4.2.7 RPM-TP (Twisted Pair)

5. 6 0 - 10 Km
1. 2 not used
3. 4 not used

JUMPER ACROSS DISTANCES

twisted pair (UTP) and

SUPPORTED

connections.

Show 6 more labels / short text on this page
Magnum RPM-TP · allow both unshielded · shielded to minimize · shielded twisted pair · emissions and will · (STP) segment
Page 36 of the GarrettCom Magnum 3000 user manual — 4.2.8 BPM-BNC
Page 36 · click to enlarge
Page 36

FWD-X LED

pins not used. When the TP crossover switch is UP, the pins of the RJ-45 port are per the

standard for up-links using twisted pair wiring, i.e., the transmit and the receive pairs are

exchanged: 1 = transmit+, 2 = transmit-, 3 = receive+, 6 = receive-, other pins not used.

The Magnum BPM-BNC bridge module is equipped with a standard 10BASE2

isolate the local segment (i.e., the local nodes connected to the Magnum unit housing the

The BPM-BNC module includes an FWD-I LED and an FWD-X LED, which

FWD-I LED 2

The RJ-45 pins normally (TP crossover switch DOWN) are per the standard for hubs-to-

users twisted pair wiring1 = receive+, 2 = receive-, 3 = transmit+, 6 = transmit-, other

coax BNC connector. This BPM is self-learning and filters and forwards packets at full

Ethernet wire speed. This module is used for 10BASE2 connections and is designed to

The BPM-BNC module is designed with a special switch -selectable internal

(To help recall the right TP switch position, remember "up for up-link" ! )

BPM internally) from the connecting network (i.e., the nodes of external users and

termination function that eliminates the need for a "tee" connector and a 50 ohm

DOWN(or Right) for workstations and user connections.

UP (or Left) for Up-Link connections to other hubs, etc.

terminator. For switch details, refer to the RPM-BNC section, 3.2.1

devices connected through the BPM’s media connector).

local Magnum hub or stack.. The FWD-

packets are being forwarded OUT of the

packets are being forwarded INTO the

X LED blinks GREEN to indicate that

are visible from the front. The FWD-I

LED blinks GREEN to indicate that

local Magnum hub or stack.

4.2.8 BPM-BNC

Show 5 more labels / short text on this page
Internal Termination · Slide Switch · Magnum BPM-BNC · 10BASE2 Connector · Standard BNC
Page 37 of the GarrettCom Magnum 3000 user manual — 4.2.9 BPM-AUI
Page 37 · click to enlarge
Page 37

FWD-X LED

FWD-X LED

FWD-I LED

This local-bridge module is equipped with a 15 pin female AUI connector and

FWD-I LED 2

LINK LED

FWD-X are identical to those of the BPM-BNC (Section 2.2.7). In addition, this module

has a GREEN LINK LED, that is always on when the attached fiber link is operational.

a slide-lock. It is self-learning and filters and forwards packets at full Ethernet wire

equipped with a dual ST-type connector. It is self-learning and filters and forwards

The Magnum BPM-FST is a multi-mode fiber optic local-bridge module

The RPM-AUI connector supports standard IEEE signals, which are

transceiver device. The BPM-FST has three status LEDs. FWD-I and

with one FWD-I LED and one Magnum BPM-AUI

FWD-X LED, which are identical to those of the BPM-BNC (Section 2.2.7).

10BASE-FL, FOIRL ST Connectors

summarized in Table 3.2.2 of Section 3.2.2.

transceiver is required when connecting to a

used for 10BASE-FL segments, this module

The BPM-AUI card is equipped

packets at full Ethernet wire speed. When

supports fiber optic transmission distances

supports fiber segments of up to 1000m in

up to 2000m. For FOIRL applications, it

isolation from a 10BASE5 (ThickNet)

ThickNet segment and the BPM-AUI

transceiver functionality and does not

speed. It is used to provide segment

backbone or any AUI segments. A

length. The BPM-FST includes full

supports this convention.

4.2.9 BPM-AUI

4.2.10 BPM-FST

Show 5 more labels / short text on this page
Magnum BPM-FST · 1 Standard 15-pin · require an external · with slide-lock · female AUI
Page 38 of the GarrettCom Magnum 3000 user manual — 4.2.11 BPM-TP
Page 38 · click to enlarge
Page 38

eliminates the need for a special twisted-pair crossover cable. For MDI-X switch details,

supports Ethernet twisted pair segments of any standard length. The RJ-45 connector is

shielded to minimize emissions and will allow both unshielded twisted pair (UTP) and

The BPM-TP will support 10BASE-T unshielded twisted pair wiring (UTP)

FWD-X LED

The Magnum BPM-TP card is equipped with a single RJ-45 connector and

The BPM-TP module is also equipped with a Media Dependent Interface-

FWD-I LED

LINK LED

Crossover (MDI-X) slide switch to allow for cascaded connections. This feature

of this BPM are the same as those of the Magnum BPM-TP

shielded twisted pair (STP) segment connections.

BPM-FST (Section 3.2.10).

refer to the RPM-TP section, 3.2.7.

segment distances up to 100m (325

ft.), or shielded twisted pair wiring

LINK, FWD-I, and FWD-X LEDs

module is designed with internal

(STP) of 150m (500 ft.). This

transceiver functionality. The

4.2.11 BPM-TP

Show 5 more labels / short text on this page
MDI-X Cross-over · Slide Switch · Shielded RJ-45 · Connector · environments with maximum
Page 39 of the GarrettCom Magnum 3000 user manual — Agents
Page 39 · click to enlarge
Page 39

hardware agent. Both versions follow standard MIB I and MIB II protocol conventions.

The "MB" version is ideal for agents that are part of the initial configuration, and for the

(GetRequest, GetNextRequest, GetRespose, SetRequest and Trap), and allow monitoring

and changing of the target device's configuration and parameters as well as reporting the

attached to the master printed circuit board inside each Magnum 3012 or 3024 unit. The

embedded agent essentially consists of an embedded computer configuration built around

allows all units within a Magnum stack to be managed from a single SNMP agent via the

The embedded agent board is equipped with an externally accessible 9-pin RS-

(Model 3000-MB) which resides directly within the Magnum 3024 or 3012 box. In the

alternate version, the Magnum SNMP agent board is available in a separate box (Model

3000-AGT) that is the same size as a 3024 or 3012 unit, and has its own internal power

smaller stacks and single-unit systems. The "AGT" version is convenient for field add-

Standard Repeater MIB ( MIB I & MIB II) and the Monitor and Address Tracking MIB

supply and Inter Repeater Bus (IRB) connections to fit it into a Magnum 3000 stack.

EPROMs on the agent board contain fixed data and program firmware. The

5.0 Introduction - Simple Network Management Protocol (SNMP)

In one version, the Magnum SNMP agent is offered as an embedded board

a 386 CPU, and is designed with an interface to the Inter-Repeater-Bus (IRB). This

The embedded Magnum SNMP agent is a daughter board that is directly

232 serial connector, referred to as "P1". This connector may be used to set the IP

There are two configuration options (versions) of the Magnum SNMP

Magnum SNMP agents support all standard basic SNMP commands

This chapter describes the Magnum 3000 SNMP agent products.

address and configuration files of the Magnum agent if necessary.

5.1.1 Embedded SNMP Agent, Model 3000-MB

ons of the SNMP agent option and for large stacks.

device alarms from a network management station.

5.1 SNMP Agents Description

IRB that interconnects the stack.

Agents

Page 40 of the GarrettCom Magnum 3000 user manual — PWR
Page 40 · click to enlarge
Page 40

Repeater Bus (IRB). There are two IRB connectors at the right-rear, permitting the agent

box unit to be installed at the bottom or top of a stack using one IRB connector, or to be

purposefully. Similarly, the agent operates in the stack attached to the IRB and does not

collection and execution functions, and operates as the local controller and interface to

inserted into the middle of a stack using two IRB connectors. The IRB cable connectors

agent is designed so that it cannot be disconnected by network managers accidentally or

extensions data are in this firmware. The firmware in the EPROMs performs the data

Figure 5.1bMagnum 3000 Agent Box, Model 3000-AGT, Rear View

The Magnum 3000 SNMP Agent Box operates the same as the embedded

dimensions as a 3024 or 3012 so that it fits neatly into a Magnum 3000 stack. It is a

The Magnum 3000-AGT agent box is connected into a stack by the Inter-

management software packages as a separate port or user. For network integrity, the

The agent logically resides on the IRB and will not be visible to network

board agent. It is packaged as a separate unit, enclosed in a box that is the same

P3

P4

complete modular unit with its own internal auto-ranging power supply.

need to use a port in any attached Magnum 3000 unit to be connected.

configuration files for complex networks. P1: Remote Terminal

Figure 5.1aMagnum 3000 Agent Box, Model 3000-AGT, Front View

are made with "notches / keys" to insure a proper connection.

5.1.3 Standard Repeater MIB and Extensions

5.1.2 Separate Agent Box, Model 3000-AGT

P1Also used to setup IP addresses and

the network manager.

PWR

GARRETT

RS-232 Port · Magnum 3000 · SNMP Agent

Page 41 of the GarrettCom Magnum 3000 user manual — 4.2.6 RPM-SMF (Single-mode Fiber)
Page 41 · click to enlarge
Page 41

basic Standard Repeater MIB, the Magnum 3000 SNMP Agents include the Port Monitor

extensions allow for individual port statistics, including readable frames and octets, FCS

The Magnum SNMP Agents’ Address Tacking MIB extensions allow the LAN

Most SNMP network management software packages (including Castle Rock’s

necessary to temporarily remove ports from the network, such as during network testing.

A list of specific commands supported by the Magnum SNMP agent appears in

Both the Magnum 3000-MB and 3000-AGT SNMP Agents are in compliance

Repeater MIB functionality as defined by IEEE 802.3 specifications. In addition to the

and Port Address Tracking MIB extensions. Magnum SNMP Agents also comply with

The completeness of the Magnum SNMP Agents allows for in depth network

changed. This feature is useful in the compilation of network traffic statistics, since the

LAN manager software to remotely disable ports if necessary. For example, it may be

With the Magnum SNMP Agents Standard Repeater MIB commands, this can easily be

conditions. These MIB Monitor extensions can prove helpful as diagnostics in many

LAN manager is able to see not only how many frames were received, but also where

they came from. (This may be very helpful in determining the need for local segment

“SNMPc” product) allow both the standard repeater and enhanced port statistics to be

In addition to statistics compilation, Magnum SNMP Agents also allow the

with MIB1, MIB2, and the RFC 1368 Standard Repeater MIB, and fully support all

statistics generation and monitoring by LAN manager software products. While the

errors, alignment errors, runts, collisions, as well as other performance-related port

individual port, as well as the number of times the source of the port’s packets has

basic Standard Repeater MIB only provides repeater statistics, the MIB Monitor

manager to poll for the source address of the most recent packet received on an

ways, such as understanding why a port is not receiving packets.

RFC 1155-SMI, RFC 1212, RFC 1213-MIB, and RFC 1215.

accomplished through the LAN manager software.

isolation by means of a local bridge or BPM.)

viewed as a graph, chart or table.

Table 5.1.3.

Page 42 of the GarrettCom Magnum 3000 user manual — note: “ + ” indicates a statistic added via MIB extension
Page 42 · click to enlarge
Page 42

Readable Frames ATTRIBUTE GET +

Readable Octets ATTRIBUTE GET +

Frame Check Sequence Error ATTRIBUTE GET +

Alignment Error ATTRIBUTE GET +

Frame Too Long ATTRIBUTE GET +

Short Events ATTRIBUTE GET +

Runts ATTRIBUTE GET +

Late Events ATTRIBUTE GET +

Very Long Events ATTRIBUTE GET +

Data Rate Mismatches ATTRIBUTE GET +

Last Source Address ATTRIBUTE GET +

Source Address Changes ATTRIBUTE GET +

Repeater ID ATTRIBUTE GET

Repeater Group Capacity ATTRIBUTE GET

Group Map ATTRIBUTE GET

Repeater Health State ATTRIBUTE GET

Repeater Health Text ATTRIBUTE GET

Repeater Health Data ATTRIBUTE GET

Transmit Collisions ATTRIBUTE GET

Resource Type ID Name ATTRIBUTE GET

Resource Info. ATTRIBUTE GET

Group ID ATTRIBUTE GET

Group Port Capacity ATTRIBUTE GET

Port Map ATTRIBUTE GET

Port ID ATTRIBUTE GET

Port Admin. State ATTRIBUTE GET

Auto Partition State ATTRIBUTE GET

Auto Partitions ATTRIBUTE GET

Group Map Change NOTIFICATION

Port Map Change NOTIFICATION

Table 5.1.3Magnum SNMP Agent Commands

Execute Non disruptive self Test ACTION

Port Admin. Control ACTION

note: “ + ” indicates a statistic added via MIB extension

Show 5 more labels / short text on this page
Collisions ATTRIBUTE GET · Repeater Health NOTIFICATION · Repeater Reset NOTIFICATION · Reset Repeater ACTION · Variable Type
Page 43 of the GarrettCom Magnum 3000 user manual — 5.2 Installation, General Information
Page 43 · click to enlarge
Page 43

The Magnum SNMP agent is an option with the Magnum 3000 Stackable Hubs

and tested as part of a Magnum 3000 stack or single unit at the factory when specified at

and may be any combination of 3024 and 3012 units), only one SNMP agent is required,

The procedure for installing the Magnum 3000-MB in the field is a moderately

requirements, Magnum 3000 Stackable Hubs may also be upgraded in the field with the

user preference. For one Magnum 3000 stack (which may be from one to twenty units,

existing stack when a field upgrade from non-managed to embedded-agent-managed is

and Concentrators. The SNMP embedded agent, Model 3000-MB, will be configured

performance is the same. The selection of the desired version is entirely a function of

The embedded agent board, Model 3000-MB, is normally factory installed.

The following step-by-step procedure should be followed to properly install

recommended that a Magnum 3000-AGT agent box unit be chosen and added to the

With either of the two agent implementations, the agent's operation and

complex process. (To avoid complex field installation and test procedures, it is

the time of order. In order to satisfy network growth and changing network

addition of a Magnum SNMP agent box such as Model 3000-AGT.

Failure to do so may result in damage to the unit

from the chassis before attempting to remove

5.3 Installing the Embedded Agent Board, "MB"

Be sure the power cord is unplugged

and only one SNMP agent may be in use at any given time.

and/or replace an RPM card.

and will void the warranty.

5.2 Installation, General Information

STOP!!!

the Magnum SNMP embedded agent board.

desired).

Page 44 of the GarrettCom Magnum 3000 user manual — 4.2.6 RPM-SMF (Single-mode Fiber)
Page 44 · click to enlarge
Page 44

Right Side Left Side

Looking down into the Magnum 3024 or 3012 hub as shown in the illustration

Figure 4.3c below, the Embedded Agent Board mounts on top of the other printed circuit

Power Supply AC Power

The chassis cover is made in one piece, forming the top and the front of the

unit. There are 7 screws located on top and 3 on the front of the unit as shown below.

Remove these screws. Once these are removed, the chassis cover/front is easily lifted

The Magnum SNMP embedded agent daughter board, Figure 4.3d, connects

into the DB-9 connector "P1" on the back of the Magnum 3000 unit with a cable, and

GarrettCom Magnum 3000 — 4.2.6 RPM-SMF (Single-mode Fiber) diagram (page 44)
Fig. 12 · 4.2.6 RPM-SMF (Single-mode Fiber)

boards in the left-rear area of the unit. Three screws with stand-offs hold it firmly in

Figure 5.3bMagnum 3024, Top View with Cover Off
Figure 5.3aRemoving Magnum 3024 / 3012 Chassis Cover
2. Insert the Agent Board (Magnum 3024 and 3012 Hubs)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

forward and off of the chassis base. (See Figure 5.3a).

10 Phillips Head Screws

1. Remove Chassis Cover of the hub

place in the correct position.

Show 4 more labels / short text on this page
Input · Optional Bonus Port · Front of Unit · Back of Unit
Page 45 of the GarrettCom Magnum 3000 user manual — Magnum SNMP
Page 45 · click to enlarge
Page 45

upon the vintage of the hub unit being upgraded. Kits may sometimes be available from

On the back of Magnum 3000 Stackable hubs is an eight position DIP switch.

The first six positions are used to identify each unit in binary code as a Group # address.

should be set to the # 1 Group address. The "AGT" agent box unit, if used in a stack, has

From the perspective of the network manager, the Magnum SNMP agent board

or box is not visible as a separate user or port. It cannot be disabled either accidentally or

GCI's Spare Parts List with parts and instructions to suit the different unit revs. Consult

If in doubt about the vintage of your 3012 upgrade candidate, use the "AGT"

For managed stacks, the unit configured with the embedded SNMP agent in it

exact type and number of cables and connectors for this installation varies depending

plugs into the main board and into the power supply with other assorted cables. The

no Group # address itself. See also Table 4.3 and Section 2.3.2, "Group # Address

purposefully. This prevents the agent itself from being disconnected, causing an

irreversible loss of control of the entire stack from the network manager.

Figure 5.3d, Magnum 3024 and 3012, Rear View

3. Set Group # (Stack) Address - Magnum 3024/3012
Figure 5.3cEmbedded Agent Board

with GCI Tech Support for additional information.

Magnum SNMP

Agent Board

Switches 7 and 8 are not used.

box model for the upgrade.

Switch Settings".

pwr

Page 46 of the GarrettCom Magnum 3000 user manual — address\switch 1 2 3 4 5 6 1 on
Page 46 · click to enlarge
Page 46

sequence according to the Group #. (The SNMP standard defines the term "Group #" for

The SNMP Agent software resides in ROM chips on the hardware agent board.

managed by one SNMP agent. The NMS display will show the stack units arranged in

5.4 Agent Configuration, Embedded Agent and Agent Box Versions

After power up, the software begins a number of tests that check the system for normal

- The Group # Address is used by the network manager to distinguish among the

It is desirable to use Group Address # 1 for the Magnum 3024 or 3012 unit

See also Section 2.3.3, Address Switch Settings, for further information on this topic.

physical units that are combined (or grouped) in the stack to operate as one repeater

Table 5.3Eight-Position DIP Switch Configuration Table

address\switch 1 2 3 4 5 6 1 on

2 on

3 on on

4 on

5 on on

6 on on

7 on on on

8 on

9 on on

10 on on

11 on on on

12 on on

13 on on on

14 on on on

15 on on on on

16 on

17 on on

18 on on

19 on on on

20 on on

- Switch # 7 and Switch # 8 are not used.

data collection and control operations.)

which houses the embedded agent.

Page 47 of the GarrettCom Magnum 3000 user manual — 4.2.6 RPM-SMF (Single-mode Fiber)
Page 47 · click to enlarge
Page 47

If the agent board (either embedded in a unit, or in a box by itself) is operating

"Function Listing, Address" below. Then, at power up when the agent software program

does not find an IP address, it will try to get configuration information from a boot server

repeater agent and its IP address. (Note that a group # address should be set for each unit

If the network does not support BOOTP or RARP, or if you need to manually

running ANSI terminal emulation software should be connected (through a null modem

NVRAM. A legitimate IP address is set into the NVRAM at the factory, permitting the

For more complex networks where the IP address is to be set from a server on

3000 stack by reading the group # addresses of all of the units in the stack. The stacked

change the agent's IP address to a user-specified address, it can be done from a terminal

operationsCPU test, EPROM CRC test, DRAM test, Network Interface Controller

cable) to the serial port "P1" located on the rear panel of the Magnum 3000 unit. The

Performing Self Diagnostics . . . (pause for 30 to 60 seconds typically)

terminal characteristics should be set to: 9600 Baud, 8 bit data, no parity, 1 stop bit.

unit or stack when new to automatically go into operation as a stand-alone network.

by using the BOOTP protocol. If this attempt fails, it will try RARP protocol. This

Next, the agent automatically determines the configuration of the Magnum

(see 4.4 above) connected to the serial port P1 on the back of the Magnum 3000 unit

During the configuration process, an ANSI compatible terminal or a PC

Garrett Communications Embedded Agent Version 02.05 (example)

Processor 3003 Controller 14 Ethernet Controller 30003003 (example)

Ethernet address 00 00 1A 18 0E 18 IP address 45.9.0.5 (example)

At power up, the agent software program will search for an IP address in

an existing network, set the NVRAM IP address to a blank using the procedure in

units, from one to twenty in number which operate as one repeater, will have one

properly, the following (example) message will appear on the terminal screen:

by using switches on the back of each unit. See Section 4.3, Table 4.3.

5.4.1 Automatic Agent IP Address Configuration.

containing the embedded agent, or to P1 on the agent box.

5.4.2 Manual IP Address Configuration.

process may require up to one minute.

test and NVRAM test.

Page 48 of the GarrettCom Magnum 3000 user manual — 1. ADDRESS: A[DDRESS] [ IP/ NAME]
Page 48 · click to enlarge
Page 48

To see a command selection menu, type: help {Cr}. On the terminal screen, a menu with

D[ISPLAY] Display whole configuration

C[OMMUNITY] [# [NAME[S] [MANAGER ]]] Communities access:

Managers - list of IP addresses and/or names

The "Address" command is used to define and/or display an agent's IP address.

Used to define or display the IP address and/or name of your BOOTP server.

B[OOTP] [IP/NAME] Bootp Server

S[UBNETMASK] [IP] Subnet mask

N[AMESERVER] [# [IP/NAME]] Name Servers

A[DDRESS] [ IP/ NAME] IP address

M[ANAGER] [# [IP/NAME [PORT] COMMUNITY]] Managers

G[ATEWAY] [# [IP [SUBNETIP [MASKIP]]]] Gateways

The agent configuration menu consists of the following commands:

command lines and the meaning of each command will appear:

On the terminal, the prompt will appear: CFG>

S - Allow Set operations

From the top menu prompt > , type: C {Cr}.

( Example>A 45.9.0.38 {Cr} )

To set an IP address, type: A [ address value ] {Cr}

( Example>B 45.9.0.171 )

(end of “terminal screen” illustration)

To display the current IP address, type: A{Cr}

To set, typeB [address value/name] {Cr}

Command or Function Listing

1. ADDRESS: A[DDRESS] [ IP/ NAME]

2. BOOTP B[OOTP] [IP/NAME]

NAMESERVER

SUBNETMASK

COMMUNITY

ADDRESS

GATEWAY

MANAGER

DISPLAY

BOOTP

EXIT

E[XIT] Exit configuration

Page 49 of the GarrettCom Magnum 3000 user manual — 3. COMMUNITY C[OMMUNITY] [# [NAME [S] [MANAGER....]]]
Page 49 · click to enlarge
Page 49

TRAPS are sent to port 162, as specified in RFC 1157. If "COMMUNITY" is absent, the

S -- allow SET operations. (If you do not "S" this command, this community will allow

Used to set the number of network manager IP addresses, and the community to which

operative, exit from the configuration menu by typing: E {Cr}. If the agent's IP address has

MANAGER -- the network manager IP addresses list, up to 10. (If the manager IP

addresses list is not present in a command line, any network manager can

TRAPS should be sent. Up to 10 managers may be set. If "PORT" is absent, then

Used to set the gateway IP address and mask. Up to 10 gateways may be set.

# -- number of community. (Up to 10 different communities may be set)

Example of two managers>C 3 MAGNUM S 45.9.0.122 45.9.1.3{Cr}

been changed, reset the agent (via a unit power down) to install the change.

communicate with this agent using this community string)

Example>D{Cr} ( All configuration information will appear )

Used to set the community string for GET and SET operations.

6. MANAGER M[ANAGER] [# [IP/NAME [PORT] COMMUNITY]]]

Example>G 3 45.9.0.112 255.255.255.0 255.0.0.0{Cr}

3. COMMUNITY C[OMMUNITY] [# [NAME [S] [MANAGER ]]]

5. GATEWAY G[ATEWAY] [# [IP [SUBNETIP [MASKIP]]]]{Cr}
3. DISPLAY To display the whole configuration file, type: D{Cr}
4. EXIT To exit from the configuration menu, type E{Cr}
To set IP mask, typeS [ mask value] {Cr}

community string "public" is used by default.

ExampleM 2 45.9.1.125 Magnum{Cr}
To delete community, typeC [#] {Cr}
To display community, typeC{Cr}
Example>S 255.255.255.0 {Cr}
7. SUBNETMASK S[UBNETMASK] [IP]{Cr}
Example>E{Cr}

only GET operations)

Page 50 of the GarrettCom Magnum 3000 user manual — 5.4.3 Other Convenience Commands
Page 50 · click to enlarge
Page 50

After new subnet configuration information is set in operation, it will reside in

agent will read the configuration information from NVRAM and start operations with it.

do NOT reside in NVRAM and will be lost at power down. From the prompt, type:

From the top menu, one can also set the time and date. The time and date

NVRAM. Powering down the Magnum 3000 will not destroy it, and at power up the

On the terminal, a message with version number and information about the processor,

To display the version and Ethernet physical address, from the prompt, type: V {Cr}

Example: >T 11/12/93 11:45 {Cr} sets the date and (military) time.

system controller, Ethernet controller, and physical Ethernet address will appear in

Ethernet Controller 30003003 Ethernet address 00 00 1A 18 0E 05 >

Garrett Communication Embedded Agent Version 01.01

5.4.3 Other Convenience Commands

T [ mm/dd/yy] [hh:mm] {Cr}

Processor 3003 Controller 13

Example>V{Cr}

response.

Page 51 of the GarrettCom Magnum 3000 user manual — 6.1 Before Calling for Assistance
Page 51 · click to enlarge
Page 51

consistently high performance in all network environments. The installation of Magnum

suggestions listed below prior to contacting your supplier. However, if you are unsure of

the procedures described in this section or if the Magnum 3000 product (3024 or 3012) is

intended to help locate, identify and correct these types of problems. Please follow the

1. If difficulty is encountered when installing or operating the unit, refer back to
3. Make sure that an AC power cord is properly attached to each Magnum 3000

product, it is recommended that the problem device is replaced with a known

5. If the problem continues after completing Step 4 above, contact your supplier

the Installation Section of the applicable chapter of this manual. Also check

electrical outlet. Use the PWR LEDs to verify each unit is receiving power.

3000 Stackable Hubs is a straightforward procedure (see INSTALLATION, Section

to make sure that the various components of the network are interoperable.

4. If the problem is isolated to a network device other than the Magnum 3000

good device. Verify whether or not the problem is corrected. If not, go to

of the Magnum 3000 unit or if unknown, contact GarrettCom, Inc.by fax,

Should problems develop during installation or operation, this section is

not performing as expected, do not attempt to repair the unit; instead contact your

2. Check the cables and connectors to ensure that they have been properly

connected and the cables/wires have not been crimped or in some way

impaired during installation. (About 90% of network downtime can be

unit. Be certain that each AC power cord is plugged into a functioning

All Magnum Ethernet products are designed to provide reliability and

Step 5 below. If the problem is corrected, the Magnum 3000 and its

2.6); the operation is also straightforward and is discussed in Section 4.

phone or email (support@garrettcom.com) for assistance.

supplier for assistance or contact GarrettCom Customer Support.

attributed to wiring and connector problems.)

associated cables are functioning properly.

6.1 Before Calling for Assistance

6.0 TROUBLESHOOTING

Page 52 of the GarrettCom Magnum 3000 user manual — 6.2 When Calling for Assistance
Page 52 · click to enlarge
Page 52

All returns for repair must be accompanied by a Return Material Authorization

d. Any particular application that, when used, appears to create the problem;

3. It is useful to include other network equipment models and related hardware,

including personal computers, workstations, terminals and printers; plus, the

4. A record of changes that have been made to your network configuration prior

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

GarrettCom will carefully test and evaluate all returned products, will repair products

number(s). Include the date(s) that you purchased the products from your

to the occurrence of the problem. Any changes to system administration

that are under warranty at no charge, and will return the warranty-repaired units to

the sender with shipping charges prepaid (see Warranty Information, Appendix A,

1. A complete description of the problem, including the following points:
2. An accurate list of GarrettCom product model(s)involved, with serial

for complete details). However, if the problem or condition causing the return

Failure symptoms, including a full description of the problem.

6.3 Return Material Authorization (RMA) Procedure

(RMA) number. To obtain an RMA number, please use this URL -

Please be prepared to provide the following information.

cannot be duplicated by GarrettCom, the unit will be returned as:

Name and phone number of your contact person.

Packing List Number (or Sales Order Number)

Please have the following information readily available:

c. The components involved in the problem;

procedures should all be noted in this record.

a. The nature and duration of the problem;

various network media types being used.

No Problem Found.

b. Situations when the problem occurs;

Name of your company / institution

Serial Number (or Invoice Number)

6.2 When Calling for Assistance

supplier.

Your shipping address · Date of installation · Product name

Page 53 of the GarrettCom Magnum 3000 user manual — APPENDIX A: WARRANTY INFORMATION
Page 53 · click to enlarge
Page 53

sheet or bag for shipping protection. ( You may retain all connectors and this

1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic

material. This material may cause electro-static shock damage to the unit.

CAUTION : Do not pack the unit in Styrofoam "popcorn" type packing

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

GarrettCom, Inc. warrants its products to be free from defects in materials

units under warranty. Testing and repair of product that is not under warranty will

Should you need to ship the unit back to GarrettCom, please follow these

replace components in the products that prove to be defective at no charge other

product has been damaged by misuse, misapplication, or as a result of service or

GarrettCom reserves the right to charge for the testing of non-defective

and workmanship for a period of three (3) years from the date of shipment by

This warranty will not be effective if, in the opinion of GarrettCom, the

Please complete the warranty card as this acts as a product registration,

During this warranty period, GarrettCom will repair or, at its option,

than shipping and handling, provided that the product is returned pre-paid to

inspecting any product returned for warranty repair which turns out not to be

3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to:

GarrettCom reserves the right to make a charge for handling and

and mail it to GarrettCom within two weeks of your purchase.

APPENDIX A: WARRANTY INFORMATION

6.4 Shipping and Packaging Information

47823 Westinghouse Dr.

Attn.: Customer Service

modification other than by GarrettCom.

GarrettCom, Inc.

result in a customer (user) charge.

Installation Guide.)

GarrettCom.

GarrettCom.

instructions:

faulty.

Fremont, CA 94539-7437

Page 54 of the GarrettCom Magnum 3000 user manual — A+
Page 54 · click to enlarge
Page 54

With the exception of the power supply, all specifications and functions of

Magnum 3000s-48VDC, 24VDC and 125VDC models are identical to those listed in

B2.0 -48VDC, 24VDC & 125VDC POWER OPTION, THEORY OF OPERATION

inside on each DC power input line behind the two external power connection terminals,

example, will neither affect the 3000s, its internal power supply, nor will it blow the fuse

The manual power “On-Off” Switch (optional) is used for powering the unit on

Magnum 3000’s are easily installed in a variety of applications where -48VDC,

24VDC & 125VDC power is used as the primary power source. The- 48VDC, 24VDC & 125VDC power configuration provides an Ethernet networking solution utilizing a special power supply in hubs with a proven track record.

Power Consumption: Model 3024 NEBS: 18 watt typical, 30 watts max.

Power Consumption: Model 3012 NEBS: 10 watt typical, 20 watts max.

Power Consumption: Model 3024 NEBS: 18 watt typical, 30 watts max.

Power Consumption: Model 3012 NEBS: 10 watt typical, 20 watts max..

Power Consumption: Model 3024 NEBS: 18 watt typical, 30 watts max.

Power Consumption: Model 3012 NEBS: 10 watt typical, 20 watts max.

The -48VDC, 24VDC & 125VDC power options are designed using diodes

the 3000s from incorrect DC input connections. An incorrect polarity connection, for

GND GND CHASSIS

FUSE +

HUB POWER SWITCH

SUPPLY

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

Power Supply (Internal 125 VDC Option) Industrial Application

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

B3.0 APPLICATIONS FOR DC POWERED HUBS

Power Supply (Internal 24 VDC Option) Industrial Application

APPENDIX B : Internal DC Power Supply Option

B1.0 SPECIFICATIONS - FOR MAGNUM 3000S

and off when it is placed into or taken out of service.

Input Voltage120 - 160 VDC
Input Voltage36 - 70 VDC
Input Voltage20 - 36 VDC

A+

A-

Power Supply (Internal -48VDC Option)

This allows the 3000s to operate only

applied to the two inputs. It protects

so that the power from an external

source can only flow into the hub.

whenever DC power is correctly

in the internal power supply.

the main manual.

Page 55 of the GarrettCom Magnum 3000 user manual — B4.0 INSTALLATION
Page 55 · click to enlarge
Page 55

The –48VDC solution is particularly useful in the telecommunication industry,

other communication companies. In addition, many high availability equipment services,

facilities often use a battery backup system to maintain operations in the event of a power

environment, where it is common for facilities to operate on 24VDC or 125VDC power.

In this picture, the -48VDC terminal block on the Magnum 3000s is located on

the rear of the unit and is equipped with three (3) screw-down lead posts. It is similar for

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage

where it is common for facilities to operate on -48VDC power. Such companies include

regular and wireless telephone service providers, Internet Service Providers (ISPs) and

The actual connection procedure is very straightforward. Simply connect the

The 125VDC solution is mainly used in power utilities, such as electrical substations,

electrical generating plants, etc. The 24VDC applications are mainly in the Industrial

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

An ON-OFF manual switch is optional for DC power . This can be used in to cut off

leads to the Magnum unit, beginning with ground. Ensure that each lead is securely

power connections and as a RESET for the Hub and / or SNMP Management Agent.

such as broadcasters, publishers, newspaper operations, brokerage firms and other

The 24VDC & 125VDC solution are particularly useful in the Industrial

24VDC and 125VDC options on the Magnum 3000s. The leads are identified as

the user may elect to Ground either + or = terminal to suit the customer’s use.

failure. It is also frequently used for computer system backup, management and

environment, such as factory floor, HVAC equipment, military equipment, etc.

_ + GND

36-70VDC

lead from 48V or –48V supply must be connected to the post labeled “+”.

Figure B4.1-48VDC Terminal Block on Magnum 3000 hubs

ON

OFF

negative (-), positive (+), and chassis ground (GND).

VDC, 24VDC & 125VDC power terminal

installation of the -48 VDC, 24VDC &

125VDC power source leads to the -48

block on the Magnum 3000 hubs. (see

This section describes the

operations monitoring equipment.

B4.0 INSTALLATION

figure at right).

tightened.

Page 56 of the GarrettCom Magnum 3000 user manual — B5.0 OPERATION
Page 56 · click to enlarge
Page 56

Power Consumption: Model 3012 NEBS: 10 watt typical, 20 watts max..

1. Minimum 14 AWG cable for connection to a Centralized DC power source. 2. Fastening torque of the lugs on the terminal block: 9 inch pound max. 3. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located
4. Disconnect Device Statement - Statement indicating that a readily accessible disconnect device shall be incorporated in the building installation wiring.
GNDTerminal for “earth” or ground wire connection to the hub chassis
GNDTerminal for “earth” or ground wire connection to the hub chassis
5. This product shall be provided with a Listed fuse or circuit breaker, rated 5 A, in the supply circuit when connected to a 48 V centralized dc source.

To order the optional –48VDC power supply factory installed, add a suffix of

Similarly, to order the optional 24VDC or 125VDC industrial specific power

DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”

supply factory installed, add a suffix of “-24VDC” or “-125VDC” after the product’s

Power Consumption: Model 3024 NEBS: 18 watt typical, 30 watts max.

Power Consumption: Model 3012 NEBS: 10 watt typical, 20 watts max..

Power Consumption: Model 3024 NEBS: 18 watt typical, 30 watts max.

“-48VDC” after the products standard model # Example: Magnum 3012-48VDC.

Operation of the Magnum 3000s with the optional -48VDC, 24VDC &

Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-125V)

standard model #. Example: Magnum 3024-24VDC, or 3012-125VDC.

Power Supply (Internal, -48VDC Dual-Source, model # Dual-Src-48V)

Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)

125VDC power supply is identical to that of the AC-powered models.

B7.0 TROUBLESHOOTING Please refer to Section 6.0

APPENDIX C : Internal DC Dual-Source Power Option

C1.0 SPECIFICATIONS - FOR MAGNUM 3000S HUBS

InputTwo separate sources, each at 36 - 70 VDC
InputTwo separate sources, each at 20 - 36 VDC

within 6 inches of the terminal block.

B6.0 ORDERING INFORMATION

B4.1 UL Requirements

(Instruction).

B5.0 OPERATION

Page 57 of the GarrettCom Magnum 3000 user manual — A-
Page 57 · click to enlarge
Page 57
GNDTerminal for “earth” or ground wire connection to the hub chassis

power supply are designed for installations where a battery plant is the power source, and

where two separate power sources are utilized in order to increase operational uptime and

d) Reverse polarity connections, if they should accidentally occur on either input, will not damage

specifications and configuration options for the Magnum 3000s -48VDC with this Dual-

Source option are identical to those listed in the Magnum 3000’s Installation and User

125VDC Dual-Source Option is identical to the standard AC-powered model. Refer to

a) The 3000s unit can receive power from either input, “A” or “B”. The hub will normally draw

Power Consumption: Model 3024 NEBS: 18 watt typical, 30 watts max.

Power Consumption: Model 3012 NEBS: 10 watt typical, 20 watts max..

With the exception of the dual DC input power connections and the power supply, all

C2.0 Magnum 3000 hubs with -48VDC, 24VDC & 125VDC Dual-Source option

The 3000s Hub with the internal -48VDC, 24VDC & 125VDC Dual-Source

the main sections of this Installation and User Guide for a detailed description of the

b) The 3000s unit will not allow power to flow from a higher voltage input to a lower voltage

c) When one correct DC input is present, the 3000s will receive power if the other DC input is

e) The 3000s will not receive power (and will not work) when both inputs are simultaneously

The functionality of the Magnum 3000s unit with the -48VDC, 24VDC &

SUPPLY A+

FUSE +

GND CHASSIS

the 3000s or power supply internally (nor will it blow the fuse in the internal power supply)

The Dual-Source DC power option is designed using diodes inside of the

HUB

GND

because of the blocking action of the diodes. This is true even if one input connection is

C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN

absent, or even if it is connected with reverse polarity or shorted or grounded.

C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION

InputTwo separate sources, each at 120 - 160 VDC

Guide, including Appendix B “Internal DC Power Supply Option”

input, i.e. the two DC power sources are not mixed together by the hub.

its power from the DC source with the highest voltage at a given time.

power is correctly applied to either or both of the two inputs

reversed while the 3000s is operating from the other source.

Magnum 3000s units and Configuration options.

A-

B-

B+

absent or are both incorrectly connected.

chassis on each DC power input line.

A diode is placed in each of the four

input lines (behind the four external

power connection terminals) so that

only flow into the unit. This allows

power from an external source can

the unit to operate whenever DC

to simplify maintenance.

Page 58 of the GarrettCom Magnum 3000 user manual — A+ AB- B+
Page 58 · click to enlarge
Page 58

power terminals as negative (B-), positive (B+). The chassis “earth” or ground (GND), is

a threaded post with a #6 nut. The Dual source terminal blocks for 24VDC and 125VDC

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve Potential”. The more “+ve” voltage

1. Minimum 14 AWG cable for connection to a Centralized DC power source. 2. Fastening torque of the lugs on the terminal block: 9 inch pound max. 3. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located

125VDC dual source leads to the –48 VDC, 24VDC and 125VDC power terminal block on the Magnum 3000s (shown in Figure C5.0 )

located on the left rear of the unit and is equipped with five (5) screw-down lead posts.

The primary terminals are identified as positive (A+), negative (A-), and the secondary

The connection procedure is straightforward. Simply connect the DC leads to

The -48VDC terminal block on the Magnum 3000s, as shown in Fig C5.0 is

Figure C5.0-48VDC Dual-Source, wiring connections to the External Terminal

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

The 24VDC & 125VDC terminal block on Magnum 3000s is similar to that

the 3000’s power terminals, positive (+) and negative (-) screws. The use of Ground

(GND) is optional; it connects to the 3000s chassis. Ensure that each lead is securely

The following must be adhered to in order to conform to UL requirements:

This section describes the proper connection of the -48VDC, 24VDC &

lead from 48V or –48V Power supply must be connected to the post labeled “+”.

the user may elect to Ground either + or = terminal to suit the customer’s use.

Block on a Magnum -48VDC with Dual-Source option

within 6 inches of the terminal block.

36-70VDC GND

described in the –48VDC info above.

A+ AB- B+

36-70VDC

C5.0 INSTALLATION

C5.1 UL Requirements

are similar.

tightened.

Page 59 of the GarrettCom Magnum 3000 user manual — C7.0 OPERATION
Page 59 · click to enlarge
Page 59

Operation of the Magnum 3000s units with -48VDC, 24VDC & 125VDC Dual

or Dual Src125V-SWITCH for the model with the ON-OFF switch.

To order the optional Dual-Source -48VDC power supply factory installed,

or Dual-Src48V-SWITCH for the model with the ON-OFF switch.

order “Dual-Src48V” as a separate line item following the product model.

following the product model. Also order for Regular or Manual Switch as

Similarly to order “Dual-Src24V” or “Dual-Src125V”, add it as a suffix

ExampleMagnum 3024-24VDC or Magnum 3012-125VDC

Dual Src24V for regular model with no ON-OFF switch

Dual-Src-48V for the regular dual-source model

Source options is identical to that of the standard models.

ExampleMagnum 3012-48VDC

C6.0 ORDERING INFORMATION

mentioned above.

C7.0 OPERATION

Ask about the GarrettCom Magnum 3000

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom Magnum 3000

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom Magnum 3000 manual PDF

59 pages·389 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…