EN
GarrettCom logo
Official user manual

GarrettCom Hubs

12 pages·89 KB·Switch·PDF·ENDEFRITNLJA
GarrettCom Hubs
Table of Contents 2 sections Corporate Headquarters: · Revisions ShowHide
Page 1 of the GarrettCom Hubs user manual — User Manual
Page 1 · click to enlarge
Page 1
GarrettCom Hubs — Corporate Headquarters: diagram (page 1)
Fig. 1 · Corporate Headquarters:
GarrettCom Hubs — Corporate Headquarters: diagram (page 1)
Fig. 2 · Corporate Headquarters:

Magnum Blade Compact PCI Hubs 10/100 Mbps & 100Mbps Hubs

GarrettCom Hubs — Magnum Blade Compact PCI Hubs 10/100 Mbps & 100Mbps Hubs diagram (page 1)
Fig. 3 · Magnum Blade Compact PCI Hubs 10/100 Mbps & 100Mbps…

User Manual

Page 2 of the GarrettCom Hubs user manual — Corporate Headquarters:
Page 2 · click to enlarge
Page 2

Printed in the United States of America.

be reproduced without prior written permission from GarrettCom, Inc.

Copyright 2001 GarrettCom, Inc. All rights reserved. No part of this publication may

registered trademark of GarrettCom, Inc.

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a

UL is a registered trademark of Underwriters Laboratories

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

cPCI Hub, consult page 9, Troubleshooting, of this User Guide.

warranties null and void. If problems are experienced with a Magnum Blade

Attempted service by unauthorized personnel shall render any and all

Part #84-00085 (08/01) Rev.C

Trademarks

Page 3 of the GarrettCom Hubs user manual — Magnum Blade
Page 3 · click to enlarge
Page 3

Magnum Blade DS12E Same as DS12 but the speed is fixed at 100Mbps, no auto-negotiation.

12-port Dual speeds 10/100 Mbps cPCI Hub with 12 RJ-45 ports, each auto sensing for 100Mbps operation. Occupies one 6U X 4HP slot, rear I/O, in a cPCI chassis. Stand alone operation, uses no cPCI Backplane connectors.

Magnum Blade DS12

Ordering Information:

measures may be required to correct the interference.

interference, in which case the user at his own expense will be required to take whatever

environment. Operation of this equipment in a residential area is likely to cause

reasonable protection against such interference when operated in a commercial

specifications in Subpart J of Part 15 of FCC rules, which are designed to provide

found to comply with the limits for a Class A computing device in accordance with the

instructions, may cause interference to radio communication. It has been tested and

installed and used properly, that is in strict accordance with the manufacturer's

To contact us the following information is provided below.

Contacting GarrettCom, Inc.

GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice.

This equipment generates, uses and can radiate frequency energy and if not

DS12 & DS12E 10/100Mbps c PCI Hubs

Radio Frequency Interference Statement

Webwww.garrettcom.com
Emailsupport@ garrettcom.com

GarrettCom, Inc. ( a.k.a. Garrett Communications, Inc.)

Magnum Blade

Show 5 more labels / short text on this page
Federal Communications Commission · Phone (510) 438-9071 · 213 Hammond Avenue · Fax (510) 438-9072 · Fremont, CA 94539
Page 4 of the GarrettCom Hubs user manual — SECTION PAGE NUMBER
Page 4 · click to enlarge
Page 4

Revisions Rev C 08/01: Change the logo structure and date to the current GarrettCom, Inc. manual standard. There are no changes to the content of the material at this time. Rev B 09/00 : Change the company name to GarrettCom, Inc. (Formerly it was Garrett Communications). There are no changes to the content of the material at this time Rev A 6/00 : This revision is the initial release of the Magnum Blade cPCI Hub user manual. .

WARRANTY REGISTRATION CARD 11

WARRANTY 10

TROUBLESHOOTING 9

HARDWARE INSTALLATION 8 Installation Procedure 8 Standalone Configuration 8 Multi-level Configurations, Cascading 8

PRODUCT SPECIFICATIONS 4 INTRODUCTION 6 General Description 6 Features 7 Package Contents 7

SECTION PAGE NUMBER

TABLE OF CONTENTS

Page 5 of the GarrettCom Hubs user manual — SPECIFICATIONS:
Page 5 · click to enlarge
Page 5

MDI-X thumb operated slide up-link switch converts top-most port# 1 on hub from a regular (= position) user segment port to a cross-over (X position) up-link port for on-off connection to a central hub or switch, or another cascaded hub or switch.

SWITCHES, MANUAL:

NETWORK CABLE CONNECTORS: All 12Ports are shielded RJ-45 female. 100Mbps: use Category 5 UTP/STP 10Mbps: use Category 3, 4, 5 UTP

OPERATING ENVIRONMENT: Ambient Temperature: 25° to 130° F ( -5° to 55°C) Storage Temperature: -40°to 185°F (-40°to 85°C) Ambient Relative Humidity: 5% to 95% (non-condensing)

6U X 4HP Form FactorNote: The unit is stand-alone; it does not plug into any cPCI backplane connectors
NETWORK STANDARDSEthernet V1.0/V2.0 IEEE 802.3: 10BASE-T, IEEE 802.3u: 100BASE-TX

PERFORMANCE: Data Rate: 10/ 100Mbps (DS12) 100Mbps (DS12E) Partitioning: Enforced after 32 consecutive collisions Auto-reconnect: Occurs after one packet of error-free transmission DS12 & DS12E: Class II Repeater MTBF: 287,864 hrs. @40°C 204,969 hrs. @55°C PDV (100Mbps Path Delay Value): 80BT Processing type: Store and Forward Auto-learning: 2K addresses Packet buffers: 512KB Latency (not including packet time): 5 µs (10 to 100Mbps and 100 to 10Mbps)

SPECIFICATIONS:

Page 6 of the GarrettCom Hubs user manual — Weight:
Page 6 · click to enlarge
Page 6

Three years, return to factory Made in USA

Warranty

NEBS compliant, certifiable as part of a cPCI system

Agency Approvals UL listed (UL1950), cUL, CE Emissions meet FCC Part 15 Class A

LK/RKSteady on when LINK is operational, flashing for receive activity

LED INDICATORS PER RJ-45 PORT:

COLCommon collision indicator, for the 100Mbps and 10Mbps domain

LED INDICATORS, Unit:

POWER SUPPLY (EXTERNAL):

100. Steady on when speed is 100Mbps

PWR: Steady on when power applied.

0.5lb. (0.25 kg)

Weight:

Dimensions:

Power Input Voltage12VDC Power Consumption: 6.5 Watts typical

10.3in H x 0.8in W x 3.3in D(262mm x 20mm x 84mm)

Page 7 of the GarrettCom Hubs user manual — PWR COL
Page 7 · click to enlarge
Page 7

COL LEDs indicates common collision at 10Mbps and 100MB respectively.

when lit. The PWR LED indicates the power is applied to the unit and the

indicate each port is operational or receiving data, and is at 100Mbpsspeed

collision at 10Mbps and 100MB. LINK / RX and 100LEDs on each port

indicates the power up of the unit and COL LEDs indicates the common

providing for convenient monitoring of network operation. PWR LEDs

standards. The Magnum Blade Hubs are equipped with LEDs per port,

alternatively to be cascaded to another hub or switch (X position).

the top-front to either connect to a user station or node (= position) or

operating speed accordingly.

100Mbps speed. There is no auto-negotiation and no uncertainty about the

domain’s bandwidth.

100Mbps domain’s bandwidth and the 10Mbps users share the 10Mbps

traffic and one for the 10Mbps traffic. The 100Mbps users share the

two internal traffic domains in Magnum Blade hubs, one for the 100Mbps

signals, adapting to match the best speed of the connected device. There are

802.3u auto sensing) and accept either 100Mbps or 10Mbps Ethernet

each 10/100Mbps auto-sensing. Each port can independently identify (via

any cPCI system, without design modifications.

with no cPCI Backplane connections used. They can be used in practically

Blade hubs provide efficient slot utilization in a 6U X 4HP-cPCI form factor

This eliminates the need for a hub in a separate box. The reliable Magnum

designed to I/O slot for a simple solution to cPCI Ethernet system problems.

INTRODUCTION General Description

LK / RX

The Magnum Blade Hubs are in compliance with the IEEE 802.3u

Magnum Blade Hubs have an up-link switch at port # 1, located on

The Magnum Blade Model DS12E has 12 RJ-45 ports, fixed at

The Magnum Blade DS12 Dual speed cPCI hub has 12 RJ-45 ports,

The Magnum Blade DS12 & DS12E compact cPCI Hubs are

Magnum Blade DS12 Hub (Front Panel w/ LEDs)

PWR COL

10/100 Mb · Magnum BLADE

Page 8 of the GarrettCom Hubs user manual — Features
Page 8 · click to enlarge
Page 8
  • Package Contents:

Features

  • Two holding screws for mounting in a 6U X 4HP Rear I/O cPCI
  • User manual (includes warranty card)
  • Short power cable with male power connector for insertion into the
  • One twelve-port dual-speed 10/100 Mbps Hub (Model DS12), or
  • Complies with IEEE802.3u 10 Mb and 100MbEthernet specifications
  • Auto-partitioning of ports receiving excessive collisions, removes
  • Class II Repeater, 80 BT PDV at 100Mbps
  • Supports Category 5 (100Mb) and Category 3 (10 Mb) UTP / STP
  • Bridge between the two speed domains (Model DS12), has 2K node
  • Global Collision status LED, indicates collisions for all ports / speeds
  • Up-link switch for cascading, port #
  • One model for auto negotiating 10/100Mbps dual-speed ports, one
  • Carrier Class, NEBS compliant, has been NEBS certified in cPCI
  • Low EMI noise, better than Class B emissions
  • High reliability, over 30 years calculated MTBF
  • No cPCI backplane connections, “universal”, can be used in any
  • Uses Rear I/O slot in cPCI chassis, keeping Ethernet cabling in the
  • Twelve Ethernet hub ports on a 6U X 4HP Form-Factor cPCI

power-input jack.

one Fast Ethernet 100Mbps-only Hub (Model DS12E)

both speeds to talk to each other

addresses and 512KB packet buffers, enables all connected users at

for 100-only.

Show 7 more labels / short text on this page
chassis slot · network faults · twisted-pair cabling · on the hub · systems · cPCI system · rear area
Page 9 of the GarrettCom Hubs user manual — PWR COL
Page 9 · click to enlarge
Page 9

Multi-level Configurations, Cascading If you want to connect more than 12 ports together, use the up-link port to connect to another hub or switch. This is called “cascading”. Simply connect the up-link port (port # 1) to any port on another hub or switch, with the up-link set to the crossover (X) position. Note that cascaded configurations should be compliant with Fast Ethernet collision domain specifications.

Stand-alone Configuration In a simple stand-alone configuration, the up-link switch is in the “=“ or upward position, and port # 1 (on the DS12 and DS12E) is used to connect to a user or other node.

HARDWARE INSTALLATION Installation Procedure 1. Connect power wires to a 12VDC source, generally available inside the Compact PCI box. 2. Insert the power plug to the power jack at the bottom inside position. This applies power to the unit. (It is low voltage, 12VDC, safe to handle when power is applied) 3. Carefully slide the DS12 hub into the Compact PCI I/0 slot and screw it tightly through upper and lower screws (provided). 4. Connect a device to a RJ-45 hub port using twisted pair cabling. For unshielded twisted pair, note that the distance between the hub and the device cannot exceed 100 m, and that the longest UTP cable path through a 100Mb collision domain (max. of two Class II cascaded hubs) should not exceed 205 meters. 5. The LINK indicator will indicate if the connection is properly made, and if there is power on the device on the other end so that the segment is ready to operate. 6. Connect each applicable device in your network using the same process. 7. Use the up-link switch on Port # 1 to make a cascaded (X-position) connection. Note: To reliably operate your network at 100Mb/s, you must use Category 5 wiring. Category 3 or Category 4 wire may sometimes seem to work, but it will normally cause data loss and unreliable operation.

PWR COL

BLADE

UP-LINK Switch for Cascading

Magnum

Page 10 of the GarrettCom Hubs user manual — TROUBLESHOOTING
Page 10 · click to enlarge
Page 10
  • If you are using the up-link port, confirm that the up-link port is in
  • Make sure the network adapter cards installed in the workstations

Other Important Tips

adapter or node, and at the hub.

If the Link / Activity LED light is not ON, check all connections at the

TROUBLESHOOTING

The RJ-45 cable must be securely attached. If the problem persists, try

  • Make sure that the cable is installed properly.
  • Turn off the power of the hub, after a while re-power the hub.
  • Try another port on the hub.
  • Check the Link / Activity LED lights on the ports. The Link LED on

If the DS12 or DS12E cPCI hub does not connect to the network,

this manual.

properly, check that the hub was set up according to the instructions in

either the Magnum Blade DS12 or DS12E cPCI hub is not functioning

position, the port operates as a normal node-connection port.

when the switch is set to the normal straight through (=, or back)

the switch is set to the crossover (X, or front) position. Alternately,

regular (node) setting. The up-link switch enables cascading when

This up-link switch is “front” for the up-link setting; “back” for

the correct position:

sure adapter drivers are loaded.

and cable connections are in good working condition. Also, make

is ON for the devices at both ends.

wiring connection is made on both ends of the wire and that power

each port in use should be ON, which indicates that the physical

a different cable.

This section contains information to help solve problems. If

Page 11 of the GarrettCom Hubs user manual — PURCHASED FROM ___________________________
Page 11 · click to enlarge
Page 11

SERIAL NUMBER (OR GCI INVOICE NUMBER)

PRODUCT NAME or MODEL

PURCHASED FROM

PLACE OF PURCHASE ___________________________

For expeditious repairs, please record the following information and have it available when consulting GCI for warranty service: DATE OF PURCHASE

HARDWARE: GarrettCom, Inc. (GCI) warrants to the original purchaser that each of its products, and all components thereof, will be free from defects in materials and/or workmanship for three years from the original date of purchase. Any warranty hereunder is extended to the original purchaser and is not assignable. In the event of malfunction or other indication of product failure attributable directly to faulty workmanship and/or materials, GCI will, at its option, repair or replace the defective products or components at no additional charge as set forth herein. Repair or replacement product will be furnished on an exchange basis and will be either reconditioned or new at the option of GCI. All replacement parts become the property of GCI. This limited warranty does not include service to repair damage to the product resulting from accident, disaster, misuse, neglect, or modification of the product. Service under this warranty may be obtained by returning the product to GCI, and only after receiving authorization by GCI by issuance of a Return Material Authorization (RMA) number, with shipping charges prepaid, in the original shipping container or like container, and with proof of date of purchase included with the returned product. The RMA number MUST be marked clearly visible on the outside of the shipping container. Any material returned without such RMA markings shall be rejected and returned to sender unopened. There shall be no warranty for either parts or labor after the expiration date of three years from the original date of purchase. Products will be returned to the purchaser after repair or replacement has been completed and by the carrier and method of delivery chosen by GCI. If the purchaser desires some other specific form of conveyance, then the purchaser shall bear the cost of the return shipment. GCI MAKES NO EXPRESS OR IMPLIED WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY. IN NO EVENT SHALL GCI BE LIABLE FOR INDIDENTAL OR CONSEQUENTIAL DEMAGES, COST, OR EXPENSES ARISING OUT OF OR IN CONNECTION WITH THE USE OF PERFORMANCE OF THE PRODUCT DELIVERED HEREUNDER.

(A.k.a. Garrett Communications, Inc.) 213 Hammond Avenue, Fremont, CA. 94539 Phone: (510) 438- 9071, Fax: (510) 438- 9072 www.garrettcom.com Email: support@garrettcom.com

GarrettCom, Inc.

Governing Law: This Limited Warranty shall be governed by the laws of the United States. Rev. 1997 SAVE FOR YOUR RECORDS

GarrettCom Limited Warranty

Page 12 of the GarrettCom Hubs user manual — G ARRETT C OM WARRANTY REGISTRATION CARD
Page 12 · click to enlarge
Page 12

COMMENTS What new product features would you like to see from GCI? - Please cut on the Dotted Lines and mail to:

IF YES, WHAT PRODUCT?

DO YOU USE NETWORK MANAGEMENT? __ YES __ NO

__CLIENT/SERVER __PEER-TO-PEER __OTHER NOS:

COMMENTS___________________________________________________________________________

NETWORK PROTOCOLS AT THIS SITE__ETHERNET ___FAST ETHERNET __GIGABIT ETHERNET ________ OTHER:______________

WHO DID THE INSTALLATION FOR THIS PRODUCT? __SELF __TECHNICAL STAFF__CONTRACTOR__OTHER:

=====SURVEY===== ETHERNET (100Mb) NETWORK MEDIA USED AT THIS SITE: __UNSHIELDED TWISTED PAIR __SHIELDED TWISTED PAIR __FIBER OPTIC, SC__ or ST__ COMMENTS

COMPANY PURCHASED FROM NAME/TITLE PHONE NUMBER ADDRESS CITY/STATE (OF INSTALL COUNTRY SITE) PURCHASE DATE PHONE PRODUCT Signature SERIAL NUMBER Comments about product or its condition at the time of sale

G ARRETT C OM WARRANTY REGISTRATION CARD

GARRETTCOM, INC A.K.A. Garrett Communications, Inc. 213 HAMMOND AVENUE FREMONT, CA 94539

Ask about the GarrettCom Hubs

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom Hubs

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom Hubs manual PDF

12 pages·89 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…