EN
GarrettCom logo
Official user manual

GarrettCom H80P

31 pages·92 KB·Switch·PDF·ENDEFRITNLJA
GarrettCom H80P
Table of Contents 25 sections Installation and User Guide · Personal Hubs · Models H80B and H80P · Magnum · … ShowHide
Page 1 of the GarrettCom H80P user manual — GARRETT
Page 1 · click to enlarge
Page 1

Installation and User Guide

Personal Hubs

Models H80B and H80P

Magnum

Emailsupport@ garrettcom.com

Corporate Headquarters:

Garrett Communications

213 Hammond Avenue Fremont, CA 94539

Phone: 510.438.9071

Fax510.438.9072

GARRETT

GARRETT

Page 2 of the GarrettCom H80P user manual — Magnum
Page 2 · click to enlarge
Page 2

parts. Attempted service by unauthorized personnel shall render any

publication may be reproduced without prior written permission from Garrett

and all warranties null and void. If problems are experienced with a

Magnum Personal Hub, consult Section 5, Troubleshooting, of this

Please use the mailing address, phone and fax numbers and email

1995 Garrett Communications, Inc. All rights reserved. No part of this

Installation and User Guide

UL is a registered trademark of Underwriters Laboratories

Emailsupport@ garrettcom.com

Personal Hub and Magnum are trademarks of Garrett

Personal Hub

Models H80B and H80P

Garrett Communications

213 Hammond Avenue Fremont, CA 94539

Phone: 510.438.9071

Part #84-00037 (07/95)
Fax510.438.9072

Ethernet is a trademark of Xerox Corporation

Magnum

Velcro is a trademark of Velcro U.S.A.

Printed in the United States of America.

Communications, Inc.

address listed below:

Communications, Inc.

User Guide.

Contacting Garrett Communications · Trademarks

Page 3 of the GarrettCom H80P user manual — Personal Hub
Page 3 · click to enlarge
Page 3
Page 3 of the GarrettCom H80P user manual — Personal Hub
Page 4 of the GarrettCom H80P user manual — Media Converters
Page 4 · click to enlarge
Page 4

Coax and Mini-Transceivers, All Types July '95

Repeater Port Modules (RPMs), 6 types for all Ethernet media

Two-Port Repeaters, internal power supply, all media types

Two-Port Repeaters, external power supply, all media types

Bridge Port Modules (BPMs), 4 types for segment isolation

9-port and 5-port Personal Hubs, with manual up-link switch 8-port and 4-port + AUI Personal Hubs, w/ man. up-link sw. 8-port + BNC Personal Hub, w/ manual up-link switch Stackable 8-port +AUI and BNC or Fiber, w/ up-link switch

Garrett Communications offers the Magnum line of Ethernet LAN

physical layer connectivity products with industry-standard

functionality. Magnum products are available worldwide through

OEMs, integrators, representatives, and international distributors.

Stackable Concentrators, SNMP optional, 13 ports

4 and 8 Port Deluxe, 2 and 4 Port Standard Models Transceivers

ETHERNET CONNECTIVITY PRODUCTS

The "X-line" of configurable MiXed Media products

"DESIGNED AND MANUFACTURED IN THE USA"

Local Bridge, full-featured, self-learning

Two RJ-45 Models, with BNC or Fiber

MAGNUM

Workgroup Bridges, all media types

8-port + AUI or Port Module option

16-port + AUI and Port Module slot 24-port + AUI and Port Module slot Personal Hubs

Overview

Workgroup Hubs ( the "ten" series)

Stackable Hubs, SNMP Optional

24-Port 10BASE-T Hub 12-Port 10BASE-T Hubs Local Bridge with SNMP

Media Converters

Fan-Outs

Mini-Concentrators, 7 ports

Page 5 of the GarrettCom H80P user manual — 1.0 SPECIFICATIONS
Page 5 · click to enlarge
Page 5

Ethernet products, and operate in networks independently

Ambient Relative Humidity:10% to 95% (non-condensing)

wiringpin 1= receive+, 2 = receive-, 3 = transmit+, 6 = transmit-, other pins

when switched it supports the standard for up-links using twisted pair wiring,

Reconnect: Occurs after 512 bits error-free transmission.

200. 250 vac at 50 Hz for "-i" Models, which have IEC power cable connector in the external

The regular RJ-45 ports support the standard for hubs-to-users twisted pair

not used. The RJ-45 port with the MDI-X switch is normally the same, but

i.e., the transmit and the receive pairs are exchanged: pin 1 = transmit+, 2 =

10BASE-T (Unshielded twisted pair) - 100 m (328 ft)

10BASE-T (Shielded twisted pair)- 150 m (492 ft) AUI Drop Cable - 50 m (164 ft)

Ethernet V1.0/2.0 IEEE 802.3: 10BASE-T, 10BASE5.

H80B8 front-mounted shielded RJ-45 (1 with up-link

Partitioning: Enforced after 32 consecutive collisions.

Ambient Temperature:32ºF to 122ºF (0ºC to 50ºC)

Power Input95 - 125 vac at 60 Hz for "-d" Models,

switch), 1 rear BNC with internal termination

(Magnum Personal Hubs are physical layer standard

(Shielded 10BASE-T connectors accept either unshielded or

10BASE2 ThinNet (BNC) - 185 m (607 ft)

shielded wiring lugs for standard twisted pair media wiring.)

H80P8 front-mounted shielded RJ-45, 1 rear

Power Supply (External) (H80B, optional for H80P):

transmit-, 3 = receive+, 6 = receive- , other pins not used.

Storage Temperature:-20ºC to 60ºC

Power Consumption10 watts max

Maximum Ethernet Segment Lengths:

1.1. Technical Specifications

1.0 SPECIFICATIONS

Data Rate10 Mbps

power unit.

of all software.)

Operating Environment:

switch.

Network Standards:

Performance:

Connectors:

DTE (male AUI)

Page 6 of the GarrettCom H80P user manual — 1.0 SPECIFICATIONS
Page 6 · click to enlarge
Page 6

up-link port for on-off connection to a backbone or another

conneciton without use of "T" connector. Right position --

Crossover) manual slide switch, converts RJ-45 port #8

from a regular (=) user segment port to a crossover (X)

internal termination, no "T" required. Left position --

(supplied with metal mounting clips, screws,

115v 60 Hz Power Supply is UL Listed, CSA certified. 230v 50 Hz Power Supply is same, also GS approved. Emissions: Meets FCC Part 15 Class A

Three years (see also Appendix A) Made in USA

Enclosure: Rugged, high strength steel enclosure.

Up-LinkMDI-X (Media Dependent Interface -
Internal Termination (H80B only)Allows BNC

external termination via "T" connector required.

Suitable for vertical or horizontal mounting

H80B, H80P4.4in x 5.0in x 0.75in

(11.2cm x 12.7cm x 1.9cm )

H80B and H80P1.0 lbs (455 gr); Power Supply: 1.0 lbs (455 gr)

Recessed LEDs to avoid damage.

and a Velcro strip)

cascaded hub.

Agency Approvals:

Cooling method:

Packaging:

Dimensions:

Switches:

Warranty:

Weight:

Convection

Page 7 of the GarrettCom H80P user manual — MODEL DESCRIPTION
Page 7 · click to enlarge
Page 7

RJ-45 ports, one with up-link switch,

H80-d-ps External 115 vac 60 Hz power supply.

H80-i-ps External 230 vac 50 Hz power supply.

Garrett Communications reserves the right to change specifications,

termination switch, external 115 vac

eight standard RJ-45 ports, one with

performancecharacteristics and/or model offerings without notice.

Magnum H80A-i Same as H80B-d, but with external

up-link switch, plus one rear DTE

Magnum H80B-d Personal Hub with eight standard

plus one BNC port with internal

Magnum H80P AUI powered Personal Hub with

230 vac 50 Hz power supply.

Magnum Personal Hubs Spare Parts

60 Hz power supply.

MODEL DESCRIPTION

(maleAUI) port.

MODEL DESCRIPTION

Magnum Personal Hubs

1.2 Ordering Information

Page 8 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 8 · click to enlarge
Page 8

Examine the shipping container for obvious damage prior

to installing this product; notify the carrier of any damage which you

believe occurred during shipment or delivery. Inspect the contents of

this package for any signs of damage and ensure that the items listed

Remove the Magnum Personal Hub from the shipping

container. Be sure to keep the shipping container should you need to

ship the unit at a later date. To validate the product warranty please

complete and return the enclosed Product Registration Card to

In the event there are items missing or damaged, contact

your supplier. If you need to return the unit, try to use the original

shipping container. Refer to Section 5, Troubleshooting, for specific

1 Velcro® Tape section, approximately 3 inches in

This section describes the Magnum H80B and H80P

1 External Power Supply, either 115v 60 Hz or

Personal Hubs, including appearance, features and possible

1 Magnum H80B or H80P Personal Hub

2.1 Inspecting the Package and Product

Garrett Communications as soon as possible.

230v 50 Hz (H80B only)

1 Product Registration Card

This package should contain:

2.0 INTRODUCTION

below are included.

return procedures.

applications.

1 User Guide · length

Page 9 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 9 · click to enlarge
Page 9

The Magnum H80B and H80P Personal Hubs are nine-port

rack cabinets or wiring closet apparatus. Personal Hubs are standard

install and use in an office or lab environment, requiring no special

Personal Hubs fit easily into the workplace environment.

Alternatively, a Velcro strip is included in the package so that the

unit may easily be installed on a wall surface, or on the back or side

plane so that wiring space is neat and minimal. The external power

The H80B and H80P Personal Hubs' RJ-45 ports support

packets, and regeneration of preamble bits for each packet received.

physical layer Ethernet products and operate independently of all

supply unit (optional for the H80P) conveniently plugs into an AC

connection of up eight workstations or other network devices over

full length 10BASE-T cable segments. Personal Hubs operate in

workplace hubs in a very compact package. They are simple to

of a desk or cabinet. All of the wiring connectors are in the same

functionality to perform signal amplification, re-timing of data

They are versatile enough to be table-top or shelf-mounted.

compliance with the IEEE 802.3 specification for repeater

2.2 Product Description

wall receptacle or power strip.

software.

Page 10 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 10 · click to enlarge
Page 10

Consistent with IEEE 802.3 specifications, Personal Hubs will detect

Personal Hubs include LINK and RX LEDs, located on top

using 10BASE-T twisted pair cabling. They are perfect for sites that

Magnum H80Bs are also well suited for small- to-medium-

associate the status LEDs for each of the ports with the appropriate

inexpensive solution for networking a personal multi-system office

have ThinNet installed and need to wire additional office space for

independent Ethernet network. They operate as self-sufficient units

collisions, extend collision fragments, and automatically partition

and re-connect individual ports in order to keep problems on one

located at the rear near the external power supply connection. For

size office or lab environments (up to eight persons) that need an

of the unit above each RJ-45 port, and one LED for DC power

observing operational information from the LEDs, it is easy to

Magnum H80B Personal Hubs provide a simple and

segment from causing downtime elsewhere on the network.

2.2.1 Magnum H80B Product Description

twisted pair.

port plug.

Page 11 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 11 · click to enlarge
Page 11

users and devices. Small independent networks built using Personal

Hubs are easily expanded by adding hubs of equal or greater capacity

handy as a piece of test equipment that can be easily inserted into a

network to provide a test port, and then removed after the testing is

minimal power, and is rugged enough to be carried in a coat pocket

The external power supply unit supplied with the H80B is

one of two types; one version for AC input power of 115 vac 60 Hz,

and one version for 230 vac 50 Hz. The 115 vac version has a small

transformer integral with a convenience power outlet plug. The 230

vac version has a small transformer integral with an IEC-type power

plug for a user-supplied AC power cord with a convenience power

to provide ThinNet and 10BASE-T Ethernet connectivity for local

via cascaded connections using the Up-Link switched port feature.

where a temporary network or network expansion is needed. It is

demonstration situations in conference rooms and in exhibitions

outlet plug. Both types include a lightweight DC power cord for

done. The H80B Personal Hub takes up minimal space, uses

The BNC port of the H80B provides 10BASE2 backbone

The H80B's small size makes it very useful for

connection to the Personal Hub's power jack.

for possible emergencies.

connectivity if required.

Page 12 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 12 · click to enlarge
Page 12

addition, the external power supply allows the H80P to function as a

the rear DTE port, this port must be connected to the AUI

operate, unless the opitonal external power supply is used.

other device to which it is connected, the Magnum H80P appears as

connectivity in the event of a power outage on the AUI segment. In

inexpensive solution for expanding a single AUI port into an eight

As an option, the H80P may be powered by an external

port hub. Since the H80P receives power through its DTE (male

worrying about access to a power outlet. To the server, router or

a standard transceiver. The rear DTE port of the unit allows for

power suppy (see Spare Part Ordering information, Section 1.3).

port of another Ethernet device to allow the H80P to

Magnum H80P Personal Hubs provide a simple and

AUI) port, it may be installed in virtually any location, without

When used for redundancy, the external supply retains local

2.2.2 Magnum H80P Product Description

direct drop cable connection to any AUI port.

standalone unit.

Page 13 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 13 · click to enlarge
Page 13

ports are available. It is handy as a piece of test equipment that can

takes up minimal space, uses minimal power, and is rugged enough

The H80P's small size makes it very useful for situations

be easily inserted into an AUI backbone to provide a test port, and

where a temporary twisted pair network is needed, and only AUI

then removed after the testing is done. The H80P Personal Hub

to be carried in a coat pocket for possible emergencies.

Page 14 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 14 · click to enlarge
Page 14

automatic per-port partitioning and re-connection. A fault

operational connections of each 10BASE-T segment to be

Operating in a stand-alone environment as a self-sufficient

providing small workgroups access to a variety of Ethernet

Personal Hubs have a rugged steel case and are compliant

Personal Hubs are simple and easy to install in most any

Personal Hubs use the "star" network topology and have

I LEDs Simplify Network Installation and Maintenance

networking services such as file sharing, E-Mail, printer

allows one RJ-45 port to be to connect into an existing

Personal Hubs are completely inter-operable with other

compliant with IEEE 802.3 specifications for 10 Mbps

CSMA/CD operation. This allows Personal Hubs to be

integrated within any standard Ethernet network and to

on one segment is isolated from the rest of the network,

Personal Hubs are equipped with a full complement of

device, Personal Hubs offer a very low cost method of

Personal Hubs provide a manual Up-Link switch that

Ethernet environment (such as the central hub for the

LEDs to provide status about basic network activity.

with rigid Class CE emission standards, making them

Ethernet-compliant network devices. Each is fully

unobtrusive and is typically mounted with Velcro.

I Interconnect to an Existing Ethernet Network

LINK LEDs for each port offer a simple way for

I Low cost, stand-alone 10BASE-T connectivity

office or lab location. The tiny package is very

I Inter-operable with other Ethernet Devices

suitable for commercial and home offices.

sharing, and other computer information.

building or area) via 10BASE-T wiring.

avoiding most network downtime.

operate with standard software.

I Robust Network Operations

2.3 Features and Benefits

verified.

I Installation Versatility · I High Quality

Page 15 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 15 · click to enlarge
Page 15

from one to multiple ports at an existing site easy, and do not require

Installation of the AUI powered H80P is a simple matter of

Magnum H80P and H80B Personal Hubs make expansion

connecting the rear DTE port to a standard AUI port (normally with

an AUI drop cable), instantly creating eight twisted pair user ports

modification to typical building wiring.

from a single AUI port.

2.4 Applications

Page 16 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 16 · click to enlarge
Page 16

with a standard ThinNet (10BASE2) segment. By using the internal

the back of the Personal Hub. In minutes, eight twisted pair ports are

simply connects the existing BNC tap to the BNC port of the H80B

power receptacle, and plugging the DC power plug into the jack on

The Magnum H80B offers a simple means of creating a

termination of the H80B, no "tee" conector is required (unless the

connected by plugging the external power supply unit into an AC

small workgroup network from a single BNC port. The installer

segment must extend beyond the H80B unit). Then, power is

available for other networked devices.

Page 17 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 17 · click to enlarge
Page 17

The H80B Personal Hub may also be used as a stand-alone

while the RJ-45 ports support up to eight user devices connected via

segments. In this application, the "Up-Link" switch is in the straight-

network for a local multi-user system such as shown in the figure.

through or = position so that the switchable up-link port is a user

The BNC port is used to support devices connected via ThinNet,

twisted pair. Full-length Ethernet segments are supported on all

port, not an up-link to another hub.

Page 18 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 18 · click to enlarge
Page 18

The installation of a Magnum H80B Personal Hub is a very

supply unit (provided as part of the unit). The small DC power cord

from the power supply plugs into the matching rear power jack of the

Personal Hub, and when power is applied the green "PWR" LED will

simple procedure. Locate an AC receptacle that is within six feet (2

meters) of the intended hub location and plug in the external power

version for 230 vac 50 Hz. Examine the power supply to make sure

convenience power outlet plug, and a lightweight DC power cord to

also includes a lightweight DC power cord to the applicable power

This section describes the installation of Magnum H80B

types; one version for AC input power of 115 vac 60 Hz, and one

small transformer integral with an IEC-type power plug for a user-

supplied AC power cord with a convenience power outlet plug. It

and H80P Personal Hubs, including mounting options and cable

The external power supply unit supplied is one of two

the version you have is the right type for your AC power system.

the applicable power jack on the hub. The 230 vac version has a

The 115 vac version has a small transformer integral with a

3.1 Magnum H80B Installation

jack on the Personal Hub unit.

3.0 Installation

be illuminated.

connections.

Page 19 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 19 · click to enlarge
Page 19

Installation of the Magnum H80P Personal Hub is a simple

Personal Hubs are easily mounted on a table-top or shelf,

procedure. Since the unit receives power from its rear DTE port, it

can be located virtually anywhere. The H80P is typically connected

names). This is useful in cases where a redundant supply is desired

or the topology of the network has changed and the DTE port is no

finished surfaces. A piece of Velcro may be used to add additional

longer being used. When using an external power supply, the unit

will still receive its power from the AUI connection as long as the

outage occur on the AUI segment, the external power supply will

continue to supply power, maintaining connectivity amongst local

users. Refer to Section 3.1 for external power supply connection

to another Ethernet device through an AUI drop cable. For AUI

It is also possible to connect an external power supply

(refer to Spare Part Ordering Information, Section 1.3, for model

port is connected and supplying suitable power. Should a power

and have four rubber feet to provide stability without scratching

connection instructions, refer to Section 3.5.2.

3.3 Table-Top or Shelf Mounting

3.2 Magnum H80P Installation

instructions.

Page 20 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 20 · click to enlarge
Page 20

stability if desired. When properly installed, the top-view LED status

mounted on a wall surface, on the side of a server unit cabinet, on the

from accidental damage in an office or lab workplace setting. Keep

A piece of Velcro mounting tape is supplied with the unit,

rubber feet. Stick the other side of the Velcro to the desired vertical

As an alternative to Velcro for vertical surface mounting,

small brackets for mounting with screws may be used. These items

Personal Hub’s case may be used to attach the brackets. Use of the

optional brackets permits the Personal Hub to be mounted in almost

The rugged steel case of the Personal Hub will protect it

an open area around the unit so that convection cooling can occur

Stick one side of the Velcro on the bottom of the hub between the

are included in the package. The metal screws in each side of the

indicators will be in plain view and easy to read. Plug in two or

more Ethernet cable segments, and your network is in operation.

and may be used to mount a Personal Hub in a vertical position.

mounting location. This permits the compact Personal Hub to be

back of a desk, or in other similar convenient locations in the

workplace where the associated cables are out of the way.

3.4 Wall (or Vertical Surface) Mounting

any desired orientation or position.

while the unit is in operation.

Page 21 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 21 · click to enlarge
Page 21

sheilded twisted pair ports and a BNC or DTE (male AUI) port. The

following sections give instructions for installing each of these media

segment, and when the DC power is present at each end as well, i.e.,

2. Connect the other end of each network segment to the

applicable workstation or user device. The "LINK" LED will be lit

with both shielded and unshielded type RJ-45 twisted pair wiring.

3. For the switched port up-link option, see Section 3.6.

for each port when the connection is made on both ends of the

Magnum H80Bs and H80P are equipped with eight

when the segment circuit is established and is ready to use.

3.5 Ethernet Media Connections

3.5.1 Twisted Pair Connections

10BASE-T media, insert the

though the hub's plugs are of

1. Using standard

male plug on one end of the

the shielded type, they will

accept and operate properly

network cable into one of

the RJ-45 female ports on

the Personal Hub. Even

types.

Page 22 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 22 · click to enlarge
Page 22

AUI) port which serves a dual purpose of supplying power to the unit

2 Control In Circuit A 11 Data Out Circuit Shield

(pin # 6) use a single twisted pair in the AUI cable.

6 Voltage Common 15 Control Out Circuit B

The Magnum H80P is equipped with a rear DTE (male

Before connecting the DTE port of the Magnum H80P,

2. Pins 4, 8, 11 and 14 may be connected to pin #1.

this connection must be completed before the unit will

function, unless an optional external power supply is

The Magnum H80P DTE connector supports standard

1 Control In Circuit Shield 10 Data Out Circuit B

7 Control Out Circuit A SHELL Protective Ground

3 Data Out Circuit A 12 Data In Circuit B

4 Data In Circuit Shield 13 Voltage Plus (+)

5 Data In Circuit A 14 Voltage Shield

8 Control Out Circuit Shield (conductive shell)

Table 3.5.2DTE Pin Assignments

Pin Function Pin Function

3.5.2 AUI Connections (Model H80P only)

IEEE signals, summarized in Table 3.5.2.

and providing backbone connectivity.

9 Control In Circuit B

being used..

(165 ft).

Page 23 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 23 · click to enlarge
Page 23

attach the 10BASE5 drop-cable directly to the DTE connector on the

with an internal termination switch next to the BNC connector. This

ends at the connection to the H80B. Some applications may require a

2. Engage the AUI connector slide lock (on the cable) to

Connect the ThinNet coax cable to the BNC connector on

the Magnum H80B in the same manner as is done for any standard

BNC connection. The BNC port of the H80B is specially equipped

"tee" connector, used as a tap, to allow the 10BASE2 coax segment

3. Connect the opposite end of the cable into a network

eliminates the need to use a "tee" connector when the BNC cable

Using the above information and steps below as a guide,

1. Plug the female end of the cable into the male DTE

3.5.3 ThinNet 10BASE2 (BNC) Connections (H80B only)

Right: Internal termination -- no "T" connector required.

Internal Termination Switch Settings:

AUI port and engage the port's slide locks.

to continue on past the H80B unit.

Left: External "T" required.

insure maximum connectivity.

connector on the H80P.

rear of the H80P.

Page 24 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 24 · click to enlarge
Page 24

10BASE-T connection to a user device (switch in the "==" position)

for up-links is not needed with Personal Hubs because of this built-in

Each H80B and H80P Personal Hub is equipped with one

MDI-X Up-Link crossover switch, connected to the right-most front

concentrator (switch in the "X" position). A special crossover cable

switch is set to the == position, the up-link segment is inoperative

RJ-45 port (port 8). This switch is used to select either a normal

or a 10BASE-T network up-link connection to another hub or

When the switchable port is wired for up-link but the

3.6 Switchable Up-Link Feature

and full bandwidth is available locally.

up-link switch feature.

Page 25 of the GarrettCom H80P user manual — 2.0 INTRODUCTION
Page 25 · click to enlarge
Page 25

Personal Hub provides full repeater functionality, cascaded units can

operate together even though there may be a full segment of distance

standards, there may normally be a maximum of four units in any one

Magnum Personal Hubs may also be cascaded in networks

networks. For example, any Personal Hub may be cascaded via the

Magnum 3000 Stackable Hubs and Concentrators) as well as with

with other Magnum Hubs (such as Magnum Workgroup Hubs and

switchable up-link port into any port of another hub. Since each

Based on the "four repeater rule" defined by Ethernet

3.7 Cascading Personal Hubs with the Up-Link Port

Personal Hubs may be cascaded in order to expand

Ethernet hubs from other manufacturers.

chain between any two users.

between them.

Page 26 of the GarrettCom H80P user manual — 4.0 OPERATION
Page 26 · click to enlarge
Page 26

that connectivity is lost between the ends of that segment or a loss of

switch is set to the X position. With the up-link switch off

segment. This provides a visual indication of network activity for re-

Partitioning and Re-connectionPersonal Hubs will automatically

ms of continuous transmissions. Network integrity is checked every

800 ms and segment re-connection occurs after one 512-bit packet is

indicators. All Personal Hubs are fully compliant with the Ethernet

segment. Each LINK LED will turn off independently in the event

hub, the LINK LED will normally be on when the up-link

partition any port where 32 consecutive collisions occur or after 6.5

Power On (PWR) LEDIlluminates GREEN to show functional

Link Status (LINK) LED (per port): Illuminates GREEN when

disabled. This permits local operation of the Personal

This section details the various operational features of

Version 2/IEEE 802.3 Repeater Specification for CSMA/CD 10

assurance of normal operation, and is helpful in troubleshooting.

Magnum Personal Hubs, including a description of the LED

there is proper connectivity on the port's 10BASE-T network

(= position), the LINK LED is off as the up-link is

Receive Packets (RX) LED (per port): Illuminates GREEN

intermittently to indicate that data is being received from the

4.1 Functional Operation, Use of LED Indicators

Mbps operation and will function accordingly.

power occurs in the segment at either end.

Hub with full bandwidth.

transmitted without an error.

4.0 OPERATION

DC power.

Page 27 of the GarrettCom H80P user manual — 4.0 OPERATION
Page 27 · click to enlarge
Page 27
Preamble RegenerationPersonal Hubs add bits to the preamble so
Fragment ExtensionPersonal Hubs will automatically add bits to a

that the output packet contains a minimum 64-bit preamble per the

ports, a jam pattern is generated on each port to create a collision

received data packet of less than 96 bits (a "fragment") so that the

CollisionsWhen carrier is detected simultaneously on multiple

condition. When a collision signal from one port is detected, it

generates a jam pattern to other ports.

forwarded packet is 96 bits long.

Ethernet standard.

Page 28 of the GarrettCom H80P user manual — 5.0 TROUBLESHOOTING
Page 28 · click to enlarge
Page 28

this section should help to locate, identify and correct such problems.

1. If difficulty is encountered when installing or operating the

Personal Hub, refer back to Section 3.0, Installation and Section 4.0,

Operation. Check to make sure that the various other components of

functioning electrical outlet. Use the PWR LEDs to verify the unit is

4. If the problem is isolated to a network device other than the

corrected, the Personal Hub and its associated cables are functioning

Should problems develop during installation or operation,

Please follow the suggestions listed below prior to contacting your

supplier. However, if you are unsure of any procedure described in

2. Check the cables and connectors to ensure that they are of
3. Make sure that the DC power cord is properly attached to

Magnum Personal Hub, it is recommended that the problem device

All Magnum Ethernet products are designed to provide

procedure (see Section 3.0, INSTALLATION); operation is very

connected, and the cables/wires have not been crimped or in some

the unit, and that the external power supply unit is plugged into a

be replaced with a known good device. Verify whether or not the

problem is corrected. If not, go to Step 5 below. If the problem is

5. If the problem continues after completing Step 4 above,

this section, or if the Magnum Personal Hub is not operating as

expected, do not attempt to repair or alter the unit. Contact your

the RJ-45 type (not RJ-11 “telephone” type), have been properly

supplier (or if unknown, contact Garrett Communications) for

contact your supplier of the Personal Hub unit (or if unknown,

environments. The installation of Personal Hubs is a simple

contact Garrett Communications) by fax, phone or email for

reliability and consistently high performance in all network

simple and is described in Section 4.0, OPERATION.

5.1 Before Calling for Assistance

5.0 TROUBLESHOOTING

way impaired during installation.

the network are operable.

receiving proper power.

assistance.

assistance.

properly.

Page 29 of the GarrettCom H80P user manual — 5.0 TROUBLESHOOTING
Page 29 · click to enlarge
Page 29

model(s) involved, with serial number(s). Include the date(s) that

3. It is useful to include other network equipment models and

configuration prior to the occurrence of the problem. Any changes

Material Authorization (RMA) number. To obtain an RMA number,

d. Any particular application that, when used, appears to

4. A record of changes that have been made to your network

to system administration procedures should all be noted in this

All returns for repair must be accompanied by a Return

contact Garrett Communications Customer Support at (510) 438-

related hardware, including personal computers, workstations,

terminals and printers; plus, the various network media types

9071 (office hours8AM - 5PM Pacific Standard Time) or send
1. A complete description of the problem, including the
2. An accurate list of Garrett Communications product

5.3 Return Material Authorization (RMA) Procedure

email to support@garrettcom.com. Please have the following

Failure symptoms, including a full description of the

Please be prepared to provide the following information.

Name and phone number of your contact person.

Packing List Number (or Sales Order Number)

c. The components involved in the problem;

a. The nature and duration of the problem;

you purchased the products from your supplier.

b. Situations when the problem occurs;

Name of your company / institution

Serial Number (or Invoice Number)

5.2 When Calling for Assistance

information available when calling:

problem.

following points:

being used.

record.

Show 4 more labels / short text on this page
Your shipping address · Date of installation · Product name · create the problem;
Page 30 of the GarrettCom H80P user manual — CAUTION
Page 30 · click to enlarge
Page 30

Garrett Communications will carefully test and evaluate all

no charge, and will return the warranty-repaired units to the sender

Garrett Communications reserves the right to charge for the

1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped

material. This material may cause electro-static shock damage

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

returned products, will repair products that are under warranty at

testing of non-defective units under warranty. Testing and repair

Do not pack the unit in Styrofoam "popcorn" type packing

Appendix A, for complete details). However, if the problem or

of product that is not under warranty will result in a customer

3. Garrett Communications is not responsible for your return shipping charges.

condition causing the return cannot be duplicated by Garrett

with shipping charges prepaid (see Warranty Information,

in a "bubble-wrap" plastic sheet or bag for shipping

Should you need to ship the unit back to Garrett

4. Ship the package to: Garrett Communications

Attn.: Customer Service

protection. ( You may retain all connectors and this

Communications, please follow these instructions:

Communications, the unit will be returned as:

5.4 Shipping and Packaging Information

CAUTION

to the unit.

No Problem Found.

Installation Guide.)

(user) charge.

213 Hammond Avenue · Fremont, CA 94539

Page 31 of the GarrettCom H80P user manual — CAUTION
Page 31 · click to enlarge
Page 31

repair or, at its option, replace components in the products that prove

misapplication, or as a result of service or modification other than by

charge for handling and inspecting any product returned for warranty

Please complete the warranty card as this acts as a product

registration, and mail it to Garrett Communications within two weeks

from defects in materials and workmanship for a period of three (3)

During this warranty period, Garrett Communications will

Garrett Communications, the product has been damaged by misuse,

Garrett Communications warrants its products to be free

This warranty will not be effective if, in the opinion of

to be defective at no charge other than shipping and handling,

Garrett Communications reserves the right to make a

years from the date of shipment by Garrett Communications.

provided that the product is returned pre-paid to Garrett

APPENDIX AWarranty Information

repair which turns out not to be faulty.

Garrett Communications.

Communications.

of your purchase.

Ask about the GarrettCom H80P

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom H80P

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom H80P manual PDF

31 pages·92 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…