Personal Hubs
Models H80B and H80P
Magnum
213 Hammond Avenue Fremont, CA 94539
GARRETT

parts. Attempted service by unauthorized personnel shall render any
publication may be reproduced without prior written permission from Garrett
and all warranties null and void. If problems are experienced with a
Magnum Personal Hub, consult Section 5, Troubleshooting, of this
Please use the mailing address, phone and fax numbers and email
1995 Garrett Communications, Inc. All rights reserved. No part of this
UL is a registered trademark of Underwriters Laboratories
Personal Hub and Magnum are trademarks of Garrett
213 Hammond Avenue Fremont, CA 94539
Ethernet is a trademark of Xerox Corporation
Velcro is a trademark of Velcro U.S.A.
Printed in the United States of America.
Communications, Inc.
address listed below:
Communications, Inc.
User Guide.
Contacting Garrett Communications · Trademarks



Coax and Mini-Transceivers, All Types July '95
Repeater Port Modules (RPMs), 6 types for all Ethernet media
Two-Port Repeaters, internal power supply, all media types
Two-Port Repeaters, external power supply, all media types
Bridge Port Modules (BPMs), 4 types for segment isolation
9-port and 5-port Personal Hubs, with manual up-link switch 8-port and 4-port + AUI Personal Hubs, w/ man. up-link sw. 8-port + BNC Personal Hub, w/ manual up-link switch Stackable 8-port +AUI and BNC or Fiber, w/ up-link switch
Garrett Communications offers the Magnum line of Ethernet LAN
physical layer connectivity products with industry-standard
functionality. Magnum products are available worldwide through
OEMs, integrators, representatives, and international distributors.
Stackable Concentrators, SNMP optional, 13 ports
4 and 8 Port Deluxe, 2 and 4 Port Standard Models Transceivers
The "X-line" of configurable MiXed Media products
"DESIGNED AND MANUFACTURED IN THE USA"
Local Bridge, full-featured, self-learning
Two RJ-45 Models, with BNC or Fiber
Workgroup Bridges, all media types
8-port + AUI or Port Module option
16-port + AUI and Port Module slot 24-port + AUI and Port Module slot Personal Hubs
Workgroup Hubs ( the "ten" series)
Stackable Hubs, SNMP Optional
24-Port 10BASE-T Hub 12-Port 10BASE-T Hubs Local Bridge with SNMP
Fan-Outs
Mini-Concentrators, 7 ports

Ethernet products, and operate in networks independently
Ambient Relative Humidity:10% to 95% (non-condensing)
when switched it supports the standard for up-links using twisted pair wiring,
Reconnect: Occurs after 512 bits error-free transmission.
The regular RJ-45 ports support the standard for hubs-to-users twisted pair
not used. The RJ-45 port with the MDI-X switch is normally the same, but
i.e., the transmit and the receive pairs are exchanged: pin 1 = transmit+, 2 =
10BASE-T (Unshielded twisted pair) - 100 m (328 ft)
10BASE-T (Shielded twisted pair)- 150 m (492 ft) AUI Drop Cable - 50 m (164 ft)
Ethernet V1.0/2.0 IEEE 802.3: 10BASE-T, 10BASE5.
Partitioning: Enforced after 32 consecutive collisions.
Ambient Temperature:32ºF to 122ºF (0ºC to 50ºC)
switch), 1 rear BNC with internal termination
(Magnum Personal Hubs are physical layer standard
(Shielded 10BASE-T connectors accept either unshielded or
10BASE2 ThinNet (BNC) - 185 m (607 ft)
shielded wiring lugs for standard twisted pair media wiring.)
Power Supply (External) (H80B, optional for H80P):
transmit-, 3 = receive+, 6 = receive- , other pins not used.
Storage Temperature:-20ºC to 60ºC
Maximum Ethernet Segment Lengths:
1.1. Technical Specifications
power unit.
of all software.)
Operating Environment:
switch.
Network Standards:
Performance:
Connectors:
DTE (male AUI)

up-link port for on-off connection to a backbone or another
conneciton without use of "T" connector. Right position --
Crossover) manual slide switch, converts RJ-45 port #8
from a regular (=) user segment port to a crossover (X)
internal termination, no "T" required. Left position --
(supplied with metal mounting clips, screws,
115v 60 Hz Power Supply is UL Listed, CSA certified. 230v 50 Hz Power Supply is same, also GS approved. Emissions: Meets FCC Part 15 Class A
Three years (see also Appendix A) Made in USA
Enclosure: Rugged, high strength steel enclosure.
external termination via "T" connector required.
Suitable for vertical or horizontal mounting
(11.2cm x 12.7cm x 1.9cm )
Recessed LEDs to avoid damage.
and a Velcro strip)
cascaded hub.
Agency Approvals:
Cooling method:
Packaging:
Dimensions:
Switches:
Warranty:
Weight:
Convection

RJ-45 ports, one with up-link switch,
H80-d-ps External 115 vac 60 Hz power supply.
H80-i-ps External 230 vac 50 Hz power supply.
Garrett Communications reserves the right to change specifications,
termination switch, external 115 vac
eight standard RJ-45 ports, one with
performancecharacteristics and/or model offerings without notice.
Magnum H80A-i Same as H80B-d, but with external
up-link switch, plus one rear DTE
Magnum H80B-d Personal Hub with eight standard
plus one BNC port with internal
Magnum H80P AUI powered Personal Hub with
230 vac 50 Hz power supply.
60 Hz power supply.
(maleAUI) port.
Magnum Personal Hubs
1.2 Ordering Information

Examine the shipping container for obvious damage prior
to installing this product; notify the carrier of any damage which you
believe occurred during shipment or delivery. Inspect the contents of
this package for any signs of damage and ensure that the items listed
Remove the Magnum Personal Hub from the shipping
container. Be sure to keep the shipping container should you need to
ship the unit at a later date. To validate the product warranty please
complete and return the enclosed Product Registration Card to
In the event there are items missing or damaged, contact
your supplier. If you need to return the unit, try to use the original
shipping container. Refer to Section 5, Troubleshooting, for specific
1 Velcro® Tape section, approximately 3 inches in
This section describes the Magnum H80B and H80P
1 External Power Supply, either 115v 60 Hz or
Personal Hubs, including appearance, features and possible
1 Magnum H80B or H80P Personal Hub
2.1 Inspecting the Package and Product
Garrett Communications as soon as possible.
230v 50 Hz (H80B only)
1 Product Registration Card
This package should contain:
below are included.
return procedures.
applications.
1 User Guide · length

The Magnum H80B and H80P Personal Hubs are nine-port
rack cabinets or wiring closet apparatus. Personal Hubs are standard
install and use in an office or lab environment, requiring no special
Personal Hubs fit easily into the workplace environment.
Alternatively, a Velcro strip is included in the package so that the
unit may easily be installed on a wall surface, or on the back or side
plane so that wiring space is neat and minimal. The external power
The H80B and H80P Personal Hubs' RJ-45 ports support
packets, and regeneration of preamble bits for each packet received.
physical layer Ethernet products and operate independently of all
supply unit (optional for the H80P) conveniently plugs into an AC
connection of up eight workstations or other network devices over
full length 10BASE-T cable segments. Personal Hubs operate in
workplace hubs in a very compact package. They are simple to
of a desk or cabinet. All of the wiring connectors are in the same
functionality to perform signal amplification, re-timing of data
They are versatile enough to be table-top or shelf-mounted.
compliance with the IEEE 802.3 specification for repeater
2.2 Product Description
wall receptacle or power strip.
software.

Consistent with IEEE 802.3 specifications, Personal Hubs will detect
Personal Hubs include LINK and RX LEDs, located on top
using 10BASE-T twisted pair cabling. They are perfect for sites that
Magnum H80Bs are also well suited for small- to-medium-
associate the status LEDs for each of the ports with the appropriate
inexpensive solution for networking a personal multi-system office
have ThinNet installed and need to wire additional office space for
independent Ethernet network. They operate as self-sufficient units
collisions, extend collision fragments, and automatically partition
and re-connect individual ports in order to keep problems on one
located at the rear near the external power supply connection. For
size office or lab environments (up to eight persons) that need an
of the unit above each RJ-45 port, and one LED for DC power
observing operational information from the LEDs, it is easy to
Magnum H80B Personal Hubs provide a simple and
segment from causing downtime elsewhere on the network.
2.2.1 Magnum H80B Product Description
twisted pair.
port plug.

users and devices. Small independent networks built using Personal
Hubs are easily expanded by adding hubs of equal or greater capacity
handy as a piece of test equipment that can be easily inserted into a
network to provide a test port, and then removed after the testing is
minimal power, and is rugged enough to be carried in a coat pocket
The external power supply unit supplied with the H80B is
one of two types; one version for AC input power of 115 vac 60 Hz,
and one version for 230 vac 50 Hz. The 115 vac version has a small
transformer integral with a convenience power outlet plug. The 230
vac version has a small transformer integral with an IEC-type power
plug for a user-supplied AC power cord with a convenience power
to provide ThinNet and 10BASE-T Ethernet connectivity for local
via cascaded connections using the Up-Link switched port feature.
where a temporary network or network expansion is needed. It is
demonstration situations in conference rooms and in exhibitions
outlet plug. Both types include a lightweight DC power cord for
done. The H80B Personal Hub takes up minimal space, uses
The BNC port of the H80B provides 10BASE2 backbone
The H80B's small size makes it very useful for
connection to the Personal Hub's power jack.
for possible emergencies.
connectivity if required.

addition, the external power supply allows the H80P to function as a
the rear DTE port, this port must be connected to the AUI
operate, unless the opitonal external power supply is used.
other device to which it is connected, the Magnum H80P appears as
connectivity in the event of a power outage on the AUI segment. In
inexpensive solution for expanding a single AUI port into an eight
As an option, the H80P may be powered by an external
port hub. Since the H80P receives power through its DTE (male
worrying about access to a power outlet. To the server, router or
a standard transceiver. The rear DTE port of the unit allows for
power suppy (see Spare Part Ordering information, Section 1.3).
port of another Ethernet device to allow the H80P to
Magnum H80P Personal Hubs provide a simple and
AUI) port, it may be installed in virtually any location, without
When used for redundancy, the external supply retains local
2.2.2 Magnum H80P Product Description
direct drop cable connection to any AUI port.
standalone unit.

ports are available. It is handy as a piece of test equipment that can
takes up minimal space, uses minimal power, and is rugged enough
The H80P's small size makes it very useful for situations
be easily inserted into an AUI backbone to provide a test port, and
where a temporary twisted pair network is needed, and only AUI
then removed after the testing is done. The H80P Personal Hub
to be carried in a coat pocket for possible emergencies.

automatic per-port partitioning and re-connection. A fault
operational connections of each 10BASE-T segment to be
Operating in a stand-alone environment as a self-sufficient
providing small workgroups access to a variety of Ethernet
Personal Hubs have a rugged steel case and are compliant
Personal Hubs are simple and easy to install in most any
Personal Hubs use the "star" network topology and have
I LEDs Simplify Network Installation and Maintenance
networking services such as file sharing, E-Mail, printer
allows one RJ-45 port to be to connect into an existing
Personal Hubs are completely inter-operable with other
compliant with IEEE 802.3 specifications for 10 Mbps
CSMA/CD operation. This allows Personal Hubs to be
integrated within any standard Ethernet network and to
on one segment is isolated from the rest of the network,
Personal Hubs are equipped with a full complement of
device, Personal Hubs offer a very low cost method of
Personal Hubs provide a manual Up-Link switch that
Ethernet environment (such as the central hub for the
LEDs to provide status about basic network activity.
with rigid Class CE emission standards, making them
Ethernet-compliant network devices. Each is fully
unobtrusive and is typically mounted with Velcro.
I Interconnect to an Existing Ethernet Network
LINK LEDs for each port offer a simple way for
I Low cost, stand-alone 10BASE-T connectivity
office or lab location. The tiny package is very
I Inter-operable with other Ethernet Devices
suitable for commercial and home offices.
sharing, and other computer information.
building or area) via 10BASE-T wiring.
avoiding most network downtime.
operate with standard software.
I Robust Network Operations
2.3 Features and Benefits
verified.
I Installation Versatility · I High Quality

from one to multiple ports at an existing site easy, and do not require
Installation of the AUI powered H80P is a simple matter of
Magnum H80P and H80B Personal Hubs make expansion
connecting the rear DTE port to a standard AUI port (normally with
an AUI drop cable), instantly creating eight twisted pair user ports
modification to typical building wiring.
from a single AUI port.
2.4 Applications

with a standard ThinNet (10BASE2) segment. By using the internal
the back of the Personal Hub. In minutes, eight twisted pair ports are
simply connects the existing BNC tap to the BNC port of the H80B
power receptacle, and plugging the DC power plug into the jack on
The Magnum H80B offers a simple means of creating a
termination of the H80B, no "tee" conector is required (unless the
connected by plugging the external power supply unit into an AC
small workgroup network from a single BNC port. The installer
segment must extend beyond the H80B unit). Then, power is
available for other networked devices.

The H80B Personal Hub may also be used as a stand-alone
while the RJ-45 ports support up to eight user devices connected via
segments. In this application, the "Up-Link" switch is in the straight-
network for a local multi-user system such as shown in the figure.
through or = position so that the switchable up-link port is a user
The BNC port is used to support devices connected via ThinNet,
twisted pair. Full-length Ethernet segments are supported on all
port, not an up-link to another hub.

The installation of a Magnum H80B Personal Hub is a very
supply unit (provided as part of the unit). The small DC power cord
from the power supply plugs into the matching rear power jack of the
Personal Hub, and when power is applied the green "PWR" LED will
simple procedure. Locate an AC receptacle that is within six feet (2
meters) of the intended hub location and plug in the external power
version for 230 vac 50 Hz. Examine the power supply to make sure
convenience power outlet plug, and a lightweight DC power cord to
also includes a lightweight DC power cord to the applicable power
This section describes the installation of Magnum H80B
types; one version for AC input power of 115 vac 60 Hz, and one
small transformer integral with an IEC-type power plug for a user-
supplied AC power cord with a convenience power outlet plug. It
and H80P Personal Hubs, including mounting options and cable
The external power supply unit supplied is one of two
the version you have is the right type for your AC power system.
the applicable power jack on the hub. The 230 vac version has a
The 115 vac version has a small transformer integral with a
3.1 Magnum H80B Installation
jack on the Personal Hub unit.
3.0 Installation
be illuminated.
connections.

Installation of the Magnum H80P Personal Hub is a simple
Personal Hubs are easily mounted on a table-top or shelf,
procedure. Since the unit receives power from its rear DTE port, it
can be located virtually anywhere. The H80P is typically connected
names). This is useful in cases where a redundant supply is desired
or the topology of the network has changed and the DTE port is no
finished surfaces. A piece of Velcro may be used to add additional
longer being used. When using an external power supply, the unit
will still receive its power from the AUI connection as long as the
outage occur on the AUI segment, the external power supply will
continue to supply power, maintaining connectivity amongst local
users. Refer to Section 3.1 for external power supply connection
to another Ethernet device through an AUI drop cable. For AUI
It is also possible to connect an external power supply
(refer to Spare Part Ordering Information, Section 1.3, for model
port is connected and supplying suitable power. Should a power
and have four rubber feet to provide stability without scratching
connection instructions, refer to Section 3.5.2.
3.3 Table-Top or Shelf Mounting
3.2 Magnum H80P Installation
instructions.

stability if desired. When properly installed, the top-view LED status
mounted on a wall surface, on the side of a server unit cabinet, on the
from accidental damage in an office or lab workplace setting. Keep
A piece of Velcro mounting tape is supplied with the unit,
rubber feet. Stick the other side of the Velcro to the desired vertical
As an alternative to Velcro for vertical surface mounting,
small brackets for mounting with screws may be used. These items
Personal Hub’s case may be used to attach the brackets. Use of the
optional brackets permits the Personal Hub to be mounted in almost
The rugged steel case of the Personal Hub will protect it
an open area around the unit so that convection cooling can occur
Stick one side of the Velcro on the bottom of the hub between the
are included in the package. The metal screws in each side of the
indicators will be in plain view and easy to read. Plug in two or
more Ethernet cable segments, and your network is in operation.
and may be used to mount a Personal Hub in a vertical position.
mounting location. This permits the compact Personal Hub to be
back of a desk, or in other similar convenient locations in the
workplace where the associated cables are out of the way.
3.4 Wall (or Vertical Surface) Mounting
any desired orientation or position.
while the unit is in operation.

sheilded twisted pair ports and a BNC or DTE (male AUI) port. The
following sections give instructions for installing each of these media
segment, and when the DC power is present at each end as well, i.e.,
applicable workstation or user device. The "LINK" LED will be lit
with both shielded and unshielded type RJ-45 twisted pair wiring.
for each port when the connection is made on both ends of the
Magnum H80Bs and H80P are equipped with eight
when the segment circuit is established and is ready to use.
3.5 Ethernet Media Connections
3.5.1 Twisted Pair Connections
10BASE-T media, insert the
though the hub's plugs are of
male plug on one end of the
the shielded type, they will
accept and operate properly
network cable into one of
the RJ-45 female ports on
the Personal Hub. Even
types.

AUI) port which serves a dual purpose of supplying power to the unit
2 Control In Circuit A 11 Data Out Circuit Shield
(pin # 6) use a single twisted pair in the AUI cable.
6 Voltage Common 15 Control Out Circuit B
The Magnum H80P is equipped with a rear DTE (male
Before connecting the DTE port of the Magnum H80P,
this connection must be completed before the unit will
function, unless an optional external power supply is
The Magnum H80P DTE connector supports standard
1 Control In Circuit Shield 10 Data Out Circuit B
7 Control Out Circuit A SHELL Protective Ground
3 Data Out Circuit A 12 Data In Circuit B
4 Data In Circuit Shield 13 Voltage Plus (+)
5 Data In Circuit A 14 Voltage Shield
8 Control Out Circuit Shield (conductive shell)
Pin Function Pin Function
3.5.2 AUI Connections (Model H80P only)
IEEE signals, summarized in Table 3.5.2.
and providing backbone connectivity.
9 Control In Circuit B
being used..
(165 ft).

attach the 10BASE5 drop-cable directly to the DTE connector on the
with an internal termination switch next to the BNC connector. This
ends at the connection to the H80B. Some applications may require a
Connect the ThinNet coax cable to the BNC connector on
the Magnum H80B in the same manner as is done for any standard
BNC connection. The BNC port of the H80B is specially equipped
"tee" connector, used as a tap, to allow the 10BASE2 coax segment
eliminates the need to use a "tee" connector when the BNC cable
Using the above information and steps below as a guide,
3.5.3 ThinNet 10BASE2 (BNC) Connections (H80B only)
Right: Internal termination -- no "T" connector required.
Internal Termination Switch Settings:
AUI port and engage the port's slide locks.
to continue on past the H80B unit.
Left: External "T" required.
insure maximum connectivity.
connector on the H80P.
rear of the H80P.

10BASE-T connection to a user device (switch in the "==" position)
for up-links is not needed with Personal Hubs because of this built-in
Each H80B and H80P Personal Hub is equipped with one
MDI-X Up-Link crossover switch, connected to the right-most front
concentrator (switch in the "X" position). A special crossover cable
switch is set to the == position, the up-link segment is inoperative
RJ-45 port (port 8). This switch is used to select either a normal
or a 10BASE-T network up-link connection to another hub or
When the switchable port is wired for up-link but the
3.6 Switchable Up-Link Feature
and full bandwidth is available locally.
up-link switch feature.

Personal Hub provides full repeater functionality, cascaded units can
operate together even though there may be a full segment of distance
standards, there may normally be a maximum of four units in any one
Magnum Personal Hubs may also be cascaded in networks
networks. For example, any Personal Hub may be cascaded via the
Magnum 3000 Stackable Hubs and Concentrators) as well as with
with other Magnum Hubs (such as Magnum Workgroup Hubs and
switchable up-link port into any port of another hub. Since each
Based on the "four repeater rule" defined by Ethernet
3.7 Cascading Personal Hubs with the Up-Link Port
Personal Hubs may be cascaded in order to expand
Ethernet hubs from other manufacturers.
chain between any two users.
between them.

that connectivity is lost between the ends of that segment or a loss of
switch is set to the X position. With the up-link switch off
segment. This provides a visual indication of network activity for re-
ms of continuous transmissions. Network integrity is checked every
800 ms and segment re-connection occurs after one 512-bit packet is
indicators. All Personal Hubs are fully compliant with the Ethernet
segment. Each LINK LED will turn off independently in the event
hub, the LINK LED will normally be on when the up-link
partition any port where 32 consecutive collisions occur or after 6.5
Link Status (LINK) LED (per port): Illuminates GREEN when
disabled. This permits local operation of the Personal
This section details the various operational features of
Version 2/IEEE 802.3 Repeater Specification for CSMA/CD 10
assurance of normal operation, and is helpful in troubleshooting.
Magnum Personal Hubs, including a description of the LED
there is proper connectivity on the port's 10BASE-T network
(= position), the LINK LED is off as the up-link is
Receive Packets (RX) LED (per port): Illuminates GREEN
intermittently to indicate that data is being received from the
4.1 Functional Operation, Use of LED Indicators
Mbps operation and will function accordingly.
power occurs in the segment at either end.
Hub with full bandwidth.
transmitted without an error.
DC power.

that the output packet contains a minimum 64-bit preamble per the
ports, a jam pattern is generated on each port to create a collision
received data packet of less than 96 bits (a "fragment") so that the
condition. When a collision signal from one port is detected, it
generates a jam pattern to other ports.
forwarded packet is 96 bits long.
Ethernet standard.

this section should help to locate, identify and correct such problems.
Personal Hub, refer back to Section 3.0, Installation and Section 4.0,
Operation. Check to make sure that the various other components of
functioning electrical outlet. Use the PWR LEDs to verify the unit is
corrected, the Personal Hub and its associated cables are functioning
Should problems develop during installation or operation,
Please follow the suggestions listed below prior to contacting your
supplier. However, if you are unsure of any procedure described in
Magnum Personal Hub, it is recommended that the problem device
All Magnum Ethernet products are designed to provide
procedure (see Section 3.0, INSTALLATION); operation is very
connected, and the cables/wires have not been crimped or in some
the unit, and that the external power supply unit is plugged into a
be replaced with a known good device. Verify whether or not the
problem is corrected. If not, go to Step 5 below. If the problem is
this section, or if the Magnum Personal Hub is not operating as
expected, do not attempt to repair or alter the unit. Contact your
the RJ-45 type (not RJ-11 “telephone” type), have been properly
supplier (or if unknown, contact Garrett Communications) for
contact your supplier of the Personal Hub unit (or if unknown,
environments. The installation of Personal Hubs is a simple
contact Garrett Communications) by fax, phone or email for
reliability and consistently high performance in all network
simple and is described in Section 4.0, OPERATION.
5.1 Before Calling for Assistance
way impaired during installation.
the network are operable.
receiving proper power.
assistance.
assistance.
properly.

model(s) involved, with serial number(s). Include the date(s) that
configuration prior to the occurrence of the problem. Any changes
Material Authorization (RMA) number. To obtain an RMA number,
d. Any particular application that, when used, appears to
to system administration procedures should all be noted in this
All returns for repair must be accompanied by a Return
contact Garrett Communications Customer Support at (510) 438-
related hardware, including personal computers, workstations,
terminals and printers; plus, the various network media types
5.3 Return Material Authorization (RMA) Procedure
email to support@garrettcom.com. Please have the following
Failure symptoms, including a full description of the
Please be prepared to provide the following information.
Name and phone number of your contact person.
Packing List Number (or Sales Order Number)
c. The components involved in the problem;
a. The nature and duration of the problem;
you purchased the products from your supplier.
b. Situations when the problem occurs;
Name of your company / institution
Serial Number (or Invoice Number)
5.2 When Calling for Assistance
information available when calling:
problem.
following points:
being used.
record.

Garrett Communications will carefully test and evaluate all
no charge, and will return the warranty-repaired units to the sender
Garrett Communications reserves the right to charge for the
material. This material may cause electro-static shock damage
returned products, will repair products that are under warranty at
testing of non-defective units under warranty. Testing and repair
Do not pack the unit in Styrofoam "popcorn" type packing
Appendix A, for complete details). However, if the problem or
of product that is not under warranty will result in a customer
condition causing the return cannot be duplicated by Garrett
with shipping charges prepaid (see Warranty Information,
in a "bubble-wrap" plastic sheet or bag for shipping
Should you need to ship the unit back to Garrett
Attn.: Customer Service
protection. ( You may retain all connectors and this
Communications, please follow these instructions:
Communications, the unit will be returned as:
5.4 Shipping and Packaging Information
to the unit.
No Problem Found.
Installation Guide.)
(user) charge.
213 Hammond Avenue · Fremont, CA 94539

repair or, at its option, replace components in the products that prove
misapplication, or as a result of service or modification other than by
charge for handling and inspecting any product returned for warranty
Please complete the warranty card as this acts as a product
registration, and mail it to Garrett Communications within two weeks
from defects in materials and workmanship for a period of three (3)
During this warranty period, Garrett Communications will
Garrett Communications, the product has been damaged by misuse,
Garrett Communications warrants its products to be free
This warranty will not be effective if, in the opinion of
to be defective at no charge other than shipping and handling,
Garrett Communications reserves the right to make a
years from the date of shipment by Garrett Communications.
provided that the product is returned pre-paid to Garrett
repair which turns out not to be faulty.
Garrett Communications.
Communications.
of your purchase.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.