Installation and User Guide

email support@garrettcom.com
47823 Westinghouse Dr. Fremont, CA 94539
GarrettCom, Inc.
ww m com w GarrettCo. .
Fax (510) 438-9072

render all warranties null and void. If problems are experienced with Magnum
Copyright © 2005 GarrettCom, Inc. All rights reserved. No part of this publication may
GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch, Edge Switch
no user serviceable parts. Attempted service by unauthorized personnel shall
ES42 10/100 Mb/s Edge Switch products, consult Section 5, Troubleshooting,
are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.
be reproduced without prior written permission from GarrettCom, Inc.
Installation and User Guide
UL is a registered trademark of Underwriters Laboratories
NEBS is a trademark of Telcordia Technologies
Ethernet is a trademark of Xerox Corporation
Printed in the United States of America.
of this User Guide.
Trademarks

This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user, at his own expense, will be required to take
Federal Communications Commission
whatever measures may be required to correct the interference.

Please use the mailing address, phone and fax numbers and email address listed below:
47823 Westinghouse Dr. Fremont, CA 94539
GarrettCom, Inc.
Fax (510) 438-9072


3.8 Connecting Ethernet Media ............................................................... 48
3.8.1 Connecting Twisted Pair............................................................. 50 3.8.2 Connecting Fiber Optic ST-type, “twist-lock”........................... 51
3.8.3 Connecting Fiber Optic SC-type, "Snap-In".............................. 52
3.8.4 Connecting Single-Mode Fiber Optic........................................ 52
3.8.5 Power Budget Calculations for ES42 Series, Fiber Media ........ 53
3.8.6 Connections to NICs which support Auto-Neg RJ-45 ports...... 55
4.0 OPERATION ....................................................................................... 56
4.1 Dual-Speed Functionality, and Switching ......................................... 56
4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing................ 58
4.3 Dual LEDs, Front-panel and side-panel (Magnum ES42 Series) .... 59
4.4 Hardware operated Alarm Contact for monitoring power 60 5.0 TROUBLESHOOTING 61
5.2 When Calling for Assistance ............................................................. 64
5.3 Return Material Authorization (RMA) Procedure............................. 65

APPENDIX A: WARRANTY INFORMATION......................................... 69
GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or
model offerings without notice.

Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.
100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3u
When a port is operating at 100Mbps:
When a port is operating at 10 Mbps:
Data Rate: 10 Mbps
Packet-Processing Between Domains
Auto-learning: 2K address table
Data Rate: 100Mbps
1.1 Technical Specifications
1.0 SPECIFICATIONS
Ports Performance
Network Standards

(allow to flush the internal address buffer , and qualify to use with S-Ring and
Latency (not including packet time): 100 to 10 Mbps: 5µs 10 to 100Mbps: 15µs Path Delay Value: 50 BT on all ports
Maximum Ethernet Segment (or Domain) Lengths
Address buffer age-out time: 300 sec.

ES42P: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL).
ES42H: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL).
-40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests.
-58ºF to 212ºF (-50ºC to 100ºC) Short term per IEC Type tests.
Conformal Coating (optional) for humidity protection
Operating Environment
altitude.
Storage Temperature, · ES42H to -20ºC · ES42P to -40ºC

temperature un-controlled location models have closed cases to withstand dirt and use
Internal 60VA relay contact: Open for power Off, closed for power On (Hardware).
Convection on the office model. The hardened (H) factory floor and premium (P)
ALARM RELAY Terminal Block, H and P models only, two screw terminals:
special thermal techniques to transfer heat to the outside of the case for cooling.
3.7 in H x 3.0 in W x 1.7 in D (9.4 cm x 7.6 cm x 4.3 cm)
Enclosure: Rugged sheet metal (Steel).
Dimensions of the Switch unit:
Packaging:

All models have an (8-15)VDC output with 6ft long cord and a 2.5mm center +ve jack. The
These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked
500mA).When connected to a 48V centralized DC source, these products shall be provided
“Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output
voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to
external AC power supplies are temperature rated to match the Edge Switch ratings.
North America (-d) models. Input: direct plug-in 95-125vac at 60 Hz.
with a Listed 5 A DC fuse in the supply circuit.
Output:12vdc, 1Amps

North America (-Pd) models. Outdoor temperature rated. Input: 6ft AC power cord to IEC
International (-Hi) models. Factory floor temperature rated. Input: IEC 320 connector on
North America (-Hd) models. Hardened, factory floor temperature rated. Input: 6ft AC
International (-Pi) models. Outdoor temperature rated. Input: IEC 320 connector on the
3power cord to IEC 320 connector on the 100-240vac 47-63Hz external power adapter. Output:12vdc, 1.25Amps
the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord
100-240vac 47-63Hz external power adapter. Requires a user supplied power cord. Output:12vdc, 2Amps.
320 connector on the100-240vac 47-63Hz external power adapter. Output:12vdc, 2Amps.
Factory Floor Models (H) Ratings (-25 to 60°C)
Output:12vdc, 1.25Amps.
supplied AC power cord.
Output:12vdc, 1Amps


the DC terminal block. Power supply protection is provided by internal diodes.
Power Consumption, all models: 7.0 watts typical, 9 watts max.
24V DC internal (range 10 to 36V DC),
-48V DC internal (range 30 to 60V DC),+ , -, ground.
block for +, -, ground along with 12VDC jack
12V DC internal (range 8.0 to 15V DC),
Power Consumption: See Section 3.6.

10/100: Steady ON for 100Mbps; OFF for 10 Mbps(copper ports only) LK/ACT: Steady ON for LINK (LK) with no traffic, BLINKING indicates
choice of multimode SC, ST, LC or MTRJ or single mode SSC, SSCL, SST or
SLC connectors. (By default factory settings is at “Full” duplex on fiber ports)
RJ-45 Ports: support 100BASE-TX and 10BASE-T with auto-cross (MDIX).
They are shielded 8-pin female connectors for shielded (STP) and unshielded
port is transmitting / receiving (ACT).
(UTP) Cat 3, 4, 5 cable.
Port Connectors:

Mean Time Between Failure (MTBF) – over15 years, Telcordia (Bellcore) Method
UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A.
IEC61850 EMC and Operating Conditions Class C Power Substations
Metal mounting clips for panel mounting: included
NEBS L3 and ETSI compliant.

ES42P-2ff-Pd, Pi = Premium (P), two 10/100 RJ-45+ one 10Mb Fiber port for un-controlled(outdoor)
The “2ff” field is for selection of the desired “fiber flavor” as listed below. The 1ff (one fiber +five RJ-
ES42H-2ff-48VDC = Same as ES42H-24VDC model, except -48VDC power input replaces 24VDC.
(-25 to 60C) using a direct DC ( 8-15VDC) and/or external AC hardened power
ES42H-2ff-24VDC = Same as ES42H-12VDC model, except 24VDC power input replaces 12VDC.
ES42P-2ff-24VDC = Same as ES42P-12VDC model, except 24VDC power input replace 12VDC.
1.2 Summary of models and descriptions: Note: The ES42 model # consists of the base unit type and the power input. Insert S for sgl-mode
, the fiber flavor (2ff) and the power input. H- hardened, P-premium, R- Din –Rail MC2, d-
45 ports) and no ff (six RJ-45 ports only)models are also same as below, except the port options. ES42 Models (four RJ-45 10/100 with two100Mb fiber flavor option).
ES42-2ff-d or -i = four 10/100 RJ-45+ two 100Mb ST Fiber port for office and wiring closet
ES42H-2ff-12VDC = Same as ES42H model, except AC hardened power supply is not included
ES42HR-2ff-24VDC = Same as ES42H-24VDC model, but includes DIN-RAIL-MC2 mounting
ES42P-2ff-12VDC = Same as ES42P-Pd, Pi, except AC Premium Power Supply is not included.
(-40 to 75C) using direct DC (8-15VDC) and/or external AC premium power supply (included).
ES42H-2ff-Hd, Hi = Hardened (H), four RJ-45+ two 100Mb Fiber port for factory floor
(0 to 40C) using an external AC power supply.
domestic, i – international power type.
supply (included).

ES42PR-2ff-24VDC = Same as ES42P-24VDC model, but includes DIN-RAIL-MC2 mounting opt.
DUAL-SRC-24KIT= Cable kit for 24VDC input power input jack for one ES42, any 24VDC model
Other Tray configurations with power supplies and power cabling included - See Section 3.3
ES42P-2ff-48VDC = Same as ES42P-24VDC model, except -48VDC input replaces 24VDC.
“SFC”= 100Base-FX-SFC: single-mode fiber optic with FC Screw type connector, 20km.
“MTRJ”= 100Base-FX-MTRJ: multi-mode fiber optic with MTRJ type connector, 2km.
“SSCX”= 100Base-FX-SSCX: single-mode fiber optic with SC type connector, 100km.
“SSCL”= 100Base-FX-SSCL: single-mode fiber optic with SC type connector, 40km.
“SSC”= 100Base-FX-SSC: single-mode fiber optic with SC type connector, 20km.
“SLC”= 100Base-FX-SLC: single-mode fiber optic with LC type connector, 15km.
“SLC”= 100Base-FX-SLC: single-mode fiber optic with LC type connector, 15km.
DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one ES42 Series Switch,
Conformal Coating (for high humidity and “tropical” applications) - request quote.
“SST” = 100Base-FX-ST: single-mode fiber optic with ST type connector, 20km.
MC14-TRAY = 19” Rack-mount tray for 14-series Switch models, up to 16 units
“SC” = 100Base-FX-SC: multi-mode fiber optic with SC type connector, 2km.
“ST” = 100Base-FX-ST: multi-mode fiber optic with ST type connector, 2km.
See Section 3.4
Accessories

1 External Power Supply, (for -d, -i, -Hd, -Hi, -Pd and -Pi models only)
This section describes ES42 Series models, including appearance, features and
product; notify the carrier immediately of any damage which you believe occurred during
shipment or delivery. Inspect the contents of this package for any signs of damage and
2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this
1 set Metal panel mounting clips and screws (2 each)
1 User Guide (this manual)
1 MagnumES42Series Edge Switch unit,
ensure that the items listed below are included.
This package should contain:
typical applications.

Remove the Magnum ES42 Series Edge Switch from the shipping container. Be
economical solution for the growing requirements of managed networks. ES42, a six port
configurability and fiber port type options - six 10/100 copper ports or four 10/100 copper
sure to keep the shipping container should you need to ship the unit at a later date. In the
event there are items missing or damaged contact your supplier. If you need to return the
unit use the original shipping container. Refer to Section 5 Troubleshooting, for specific
versatile family of compact Edge switches, loaded with factory configurable fiber options
and AC/DC power input options with Alarm terminal block and innovative packaging is
heavy-duty industrial, military and un-controlled temperature applications, as well as an
Magnum ES42 Series Switches are designed as an Ethernet edge solution in
The Magnum ES42 family of Edge Switches have a wide breadth of port
ready to serve the needs of edge-of-the network applications.
return procedures.

covers the full range of application environments, with regular (office), Hardened (factory
Premium-rated outdoor models. The breadth of models and flavor of fiber port types offers
the best price-to-value ratio for each user and installation. The compact package is ideal for
internal address buffers in milliseconds to permit a quick change in LAN packets flow, and
ports and two 100 Mb Fiber port or five copper ports with one 100Mb Fiber port built in,
floor), and Premium-rated (outdoor) versions. Extra features for heavy-duty and extended
network structures. The Link-Loss-Feature in ES42 allows the Edge switches to flush the
temperature operation ranges are included selectively in the Hardened factory-floor and
network edge installations, and is able to be conveniently Din rail mounted to suit any
The Magnum Edge switches include Link-Loss-Learn(LLL) feature (factory
configurable on ports 1 and 2 to qualify for any redundant and self-healing managed
application.


managed switches, running STP/RSTP or S-Ring, can often provide high availability
pass the reconfiguration signal down the line to other ring switches in the redundant
structure for faster recovery. Magnum Edge switches, combined with other Magnum
Magnum E 42 S E d g e S w i t c h
The Magnum ES42 regular-package units
The ambient temperature rating is 0°C to 40°C, office grade.
are the economical base units in the ES42 Switch family. An
115vac 60Hz) or international (-I, 230vac, 50Hz) is included.
are for office and indoor wiring closet environments. These
external AC power supply for either North America (-d,
Fig 2.2a ES42 with SIX 10/100 RJ-45 only
Redundant LANs at economical cost.

A robust metal case with convection cooling is featured. Metal mounting clips are
2.2.a, b, c) units are for office and wiring closet

Fig 2.2b,c (ES42-1ff) with four10/100 RJ-45 and one & two 100Mb Fiber(ES42-2ff )
The YELLOW labeled Magnum ES42 models (as shown in Fig
Magnum E 42 S E d g e S w i tc h
included, and rack-mount tray options are available.
environments and use an external
cooling is featured. Ambient
operating temperature is 0° to
AC power supply. A ventilated
40°C. Storage temperature rating is -
metal case for convection
40°to 85°C. Metal clips are included for secure panel
ACT
LK/
Magnum E 42 S E d g e S w i t c h
PWR
LK/
ACT
100 A OR
10 F OR
ALA RM
12 VDC 1 AMP
10/ 100 · 10/ 100


mounting and optional DIN-Rail mounting. The regular model ES42 also has a rack-
H a r d e n e d Magnum E 42 S E d g e S w i t c h
MDIX ports and the full range of fiber port options. The
regular ES42 model does not have options for Alarm and
factory floor applications. The ES42H models are built
special thermal techniques and a metal case for
The Magnum ES42H Hardened units are for
with high-grade components and are constructed using
The regular model, ES42, includes Link-Loss-Learn,
mount option via an MC-TRAY.
Fig. 2.2.d Hardened ES42H-2ff
DC power.

heavy duty industrial jobs. In addition to a Hardened AC power option and jack, terminals
The ORANGE labeled Magnum ES42H hardened units (shown
resists dirt, moisture, smoke and insects. Choices of models
for external Fig. 2.2e Hardened ES42H-2ff
temperature rating of –25 to 60C is for industrial use. No internal air flow is required for
rugged metal case for heavy duty industrial applications, the
stand-alone panel-mounting, DIN-Rail, or rack-mount tray.
ES42H requires no air inflow for cooling, so the ES42H
for internal DC power choices at 8 to15V, 24V or -48V DC are included. The ambient
cooling, so it resists dust, dirt, moisture, smoke and insects. Mounting options include
applications. Using special thermal techniques and a sealed
in Fig 2.2d & e) are designed for factory floor/Industrial
LK/
ACT
H a r d e n e d Magnum E 42 S E d g e S w i tc h
PWR
ACT
LK/
100 A OR
10 F OR
A LA R M
12 VDC 1 AMP
10/ 100 · 10/ 100


controlled applications (-40 to 75°C), typically located outdoors. The
AC or internal DC power are available. Ambient operating temperature is –25°C to + 60°C
depending on the power source used. Storage temperature rating is –25°C to + 85°C.
The RED labeled Magnum ES42P Premium-rated units are for temperature un-
ES42P models are built with premium-grade extended temperature
P r e m i u m Ma gnum E 42 S
E d g e S w i tc h
techniques as the ES42H Hardened units.
to15V, 24V or -48V DC are included.
When used outdoors, the ES42P should
be protected from rain. Mounting options include
stand-alone panel-mounting, DIN-rail, or rack-mount tray. Fig
power option and jack, terminals for
components, and use similar thermal
In addition to a Premium-rated AC
internal DC power choices at 8
10/100 TX RX FH2
ACT
LK/
P r e m i u m Magnum E 42 S
E d g e S w i tc h
PWR
LK/
ACT
100 A OR
10 F OR
12 VDC 1 AMP
ALA RM
10/ 100 · 10/ 100

mounting, DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC
power are available. Ambient operating temperature is between –40°C to +75°C depending
All the premium and hardened models also come along with hardware
operated Alarm terminal block for providing extra reliability to the unit. The Alarm feature
The ES42P series (as shown in Fig. 2.2f & g) are premium rated units
The front side of the unit has four/five twisted-pair 10/100Mb switch ports and
one/two 100Mb fiber port. All the RJ-45 ports of the ES42 Series Edge switches support
premium-grade extended temperature components, the ES42P units use similar thermal
techniques to the ES42H hardened units for cooling. Mounting options include panel-
allows the ES42H & P users to be aware and to monitor any internal power failure. See
suitable for temperature un-controlled outdoor applications. Specially designed with
on the power source used. Storage temperature rating is between –40°C to +85°C.
section 44 for details.

There is another set of LEDs on the front for 10 or H and 100 or F, to indicate the data rate
which may be SC, ST, MTRJ or LC multi-mode or single-mode. The ES42’s breadth of
Two sets of LEDs to indicating the operating status of ports are mounted on the
top and front (for extra viewing advantage while rack-mounted). For each port, there are
connected correctly and showing, by blinking, when there is traffic. The LK/ACT LED’s
switching among four 10/100 auto-negotiating copper ports and two 100Mb fiber ports
as well as a set to indicate duplex for ports 1 and 2 only. 10/100 indicates the speed for
auto-cross (MDIX) operation under auto-negotiation mode. The ES42 series provides
are repeated on the front as 1 (port 1)…6 (port 6), whereas on the side as LA1…LA6 .
fiber options and well as temperature options provide many networking options and
Link and Activity (LK/ACT) LED’s on the top indicating that the media cables are
copper ports, whereas F/H indicates Full and Half duplex for fiber ports only.
solutions in a very small footprint.

The Magnum ES42 Series Edge Switches are store-and-forward switches. Each
frame (or packet) is loaded into the Switch’s memory and inspected before forwarding can
occur. This technique ensures that all forwarded frames are of a valid length and have the
There is a power (PWR) LED to indicate that the unit is turned ON. The fiber
ports on the ES42 Edge switches are multi-mode or single-mode with an SC, ST or small
The external DC power plug connector and/or “jack” and the internal DC input
While other switching technologies such as "cut-through" or "express" impose
correct CRC, i.e. they are good packets. This eliminates propagation of bad packets,
minimal frame latency, they will also permit bad frames to propagate to the Ethernet
enabling all of the available bandwidth to be used for valid information.
form factor connector (MTRJ multi mode or LC single-mode).
terminal is provided on the rear of the unit.

network. The "cut-through" technique permits collision fragment frames, which are a result
storage. (Many other switches have their packet buffer storage space divided evenly across
all ports, resulting in a small, fixed number of packets to be stored per port. When the port
capability for the maximum resources of the Magnum ES42 Series unit to be applied to all
calculated). Since collisions and bad packets are more likely when traffic is heavy, store-
and-forward switch technology enables more bandwidth to be available for good packets
memory pool, ensuring that heavily used ports receive very large buffer space for packet
of late collisions, to be forwarded--which add to the network traffic. There is no way to
filter frames with a bad CRC (the entire frame must be present in order for CRC to be
Magnum ES42 Series Edge Switch dynamically allocates buffer space from 128KB
buffer fills up, dropped packets result.) This dynamic buffer allocation provides the
To minimize the possibility of dropping frames on congested ports, each
when the traffic load is greatest.

forcing a collision signal on all receiving half-duplex ports in order to stop incoming traffic.
traffic loads, even when the traffic activity is unbalanced across the ports. Since the traffic
When the Switch detects that its free buffer queue space is low, the Switch sends
buffering and processing resumes. This flow-control sequence occurs in a small fraction of
on an operating network is constantly varying in packet density per port and in aggregate
industry standard (full-duplex only) PAUSE packets out to the devices sending packets to
which allows a traffic catch-up to occur without dropping packets. Then, normal packet
Another feature implemented in Magnum ES42 Series Edge Switches is a collision-based
that its free buffer queue space is low, the Switch prevents more frames from entering by
cause “flow control”. This tells the sending devices to temporarily stop sending traffic,
flow-control mechanism (when operating at half-duplex only). When the Switch detects
density, the Magnum ES42 Series Edge Switches are constantly adapting internally to
provide maximum network performance with the least dropped packets.
a second and is transparent to an observer.

types. The length of the frame is a variable as it is with all store-and-forward switches. For
2.4 Features and Benefits Full 100Mb or 10 Mb switching services for high performance Ethernet
Magnum ES42 Series Switches provide Fast Ethernet switching on all ports.
They perform high speed filter/forward operations on the traffic, giving each
forwarded to its destination) of the ES42 Series Edge Switches varies with the port-speed
100Mb and help to expand the Ethernet network in a very convenient and economical way.
The latency (the time the frame spends in the Switch before it is sent along or
Magnum ES42 Series Switches offer the ideal solution to efficiently and
10 Mb-to-10 Mb, 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the latency is 15 microseconds plus the packet time of 10 Mb. For 100Mb-to-100Mb forwarding, the
inexpensively connect a Twisted Pair and fiber network with 10Mb or
Reduces Network Costs and provide economical solution
port’s segment a full 100Mb (or 10 Mb) of bandwidth.
latency is 5 microseconds plus the packet time of 100Mb.

convert the media from copper to fiber and the other RJ-45 port can be used
domains. Internal address tables are self-learning, enabling users to change
Each ES42 Series Edge Switch is equipped with two sets (front and side) of
Rugged metal case, Industrial grade ES42 Series have a robust design and
are packaged in a rugged sheet metal enclosure to ensure high reliability and
Choice of one or two100Mb Fiber option, more efficient Designed as a
multi-purpose media Edge Switch, the 100Mb fiber port allows the user to
forwarding those packets from each domain that are needed on the other
LEDs to provide status information when viewed at almost any angle or
mounting arrangement whether rack (MC14- Tray) or Din-Rail mounted.
Installation is “Plug and Play”, operation is transparent to software
The Magnum ES42 Series Switches operate as hardware switches, only
port connections or 10/100 domains without affecting operations.
durability even when placed in industrial or outdoor applications.
Two sets of LEDs for viewing status from any angle.
as diagnostic port or for more connectivity.

spaces in cabinets, on table tops, in racks, walls or DIN-Rail mounted and in
Magnum ES42 Series Switches are featured with MDIX (auto-cross), which
internal power failure, and provides extra reliability to the hardened Switch
Qualified to use for temperature un-controlled “outdoor” application
ambient temperature rating between –40ºC to +75ºC for DC models and
Featuring a compact steel case with an external AC and internal DC power
The Magnum ES42P Premium rated versions of Edge Switches have an
supply, Magnum ES42 Series of Edge Switches can be installed in small
easily allow cascading with other Switch, Hubs or media Edges without
The Alarm contact option on ES42H and ES42P enables monitoring for
MDIX ports to eliminate cross-over cable while cascading All the
Hardware operated Alarm terminal block for ES42H and ES42P
Efficient Compact design, for all purpose convenient mounting
qualify for temperature un-controlled “outdoor” application.
trays such as the Magnum MC14-TRAY.
using the cross-over cable.

connectivity solutions offered by Magnum Edge Switches provide convenient, economical,
and reliable solutions as well as an active role on the managed redundant network setup for
Link-Loss-Learn feature for faster recovery in redundant managed
redundant network structure as a client switch and allow a faster recovery
“Hardened”, Red- “Premium rated (outdoor)”), and hundreds of port-type combinations,
The LLL feature qualifies the Edge switches to actively work along with
Magnum ES42 Series Edge Switches fit very well in almost any environment to enable
users to scale their networks quickly and cost effectively. The edge-of-the-network
faster recovery. The compact Magnum ES42 Series assists fast expanding network
Available in three “hardiness” models (Yellow - “office/wiring closet”, Orange –
during ring break.

requirements via providing edge support and reliability to the managed redundant network.
on Ports 1 and 2 enable easy expansion for the on-going demand of Ethernet networks. The
The Dual-Speed and Dual-media functions support a mixed environment of 10 Mbps and
provides high bandwidth and longer distance support. The up-link feature of 100Mb fiber
10/100Mbps auto-negotiating MDIX copper ports and the breadth of 100Mbps fiber ports
Switches are available for even the most extreme temperatures. The ES42’s rugged case
enable easy interfacing with existing cable plant and equipment. Models of ES42 Edge
100Mbps users with copper and fiber media. The switched full duplex fiber port also
provides extra support in the harshest industrial environments. Link-Loss-Learn is an
additional feature to provide the extra reliability to the redundant network and an
economical solution for faster recovery, during the ring break.

Mining function to store all the transaction with an ongoing demand to expand the network.
In this example, the supermarket required a Data

P r e m i u m Ma gnum E 42 S
E d g e S w i t c h
P r e m i u m Ma gnum E 42 S
E d g e S w i t c h
P r e m i u m Ma gnum E 42 S
E d g e S w i t c h
Example1. Supermarket application for ES42
P r e m i u m Ma gnum E 42 S
E d g e S w i t c h
P r e m i u m Ma gnum E 42 S
E d g e S w i t c h
P r e m i u m Ma gnum E 42 S
E d g e S w i t c h
Edge Switch ver 2
10 F OR
100 A OR
10/100 RX TX FH2
ALA RM
12 VDC 1 AMP
LK/ ACT
P r e m i u m Ma gnum E 42 S
E d g e S w i tc h
PORT PORT
LK/ ACT
10 F OR
100 A OR
ALA RM
12 VDC 1 AMP
Magnum ES42 Premium · 10/ 100

The ES42’s six ports in a small, reliable enclosure provide an effective solution to
This need can be easily met using the economical Magnum ES42 Edge Switch. Additional
requirements of supermarket. The plug-n-play ES42 not only provides a reliable solution
for transferring real-time transactions from the store to the storage device in the control
functionality includes the ability to transfer data across large distances with multi- or
flexibility along with flavor of fiber option for distance, the ES42 easily meets all the
room. The easily deployable through Din-rail option and the dual power source of
single–mode fiber while securing the LAN from EMI and wire tapping.
but also reduces operational costs significantly.

solution with their multiple options and hardened features. The two Fiber ports on the Edge
grade components, efficient cooling techniques and having no openings for dirt to enter, the
ES42 Series Edge Switches provide the very effective solution for this need. The CS14H
In this industrial networking application, the new PLC units are deployed on a network
switches are ideal for secure data communications over long distances. Built with high-
expansion, and each PLC required one (or two for redundancy) Ethernet ports to carry
status and control data to the control center. The ES42H and CS14H provide a good
offers additional and affordable fiber connectivity to the ES42H where needed.


M a g n u m E 4 2 S
E d g e S w i t c h
ES42H in a Industrial application
P r e m i u m M a g n u m E 4 2 S
E d g e S w i t c h
1 3 5 7 9 11 13 15 17 19 21 23
2 4 6 8 10 12 14 16 18 20 22 24
G arre ttCo m
CONSO LE PORT
10/100 TX RX FH2
10/100 RX TX FH2
LK/ ACT
M a g n u m E 4 2 S
P r e m i u m
E d g e S w i t c h
100 A O R
PWR
PORT PORT
10 F OR
A L A R M
12 VDC 1 AMP
G arre ttCo m
PWR
CONSOLE PORT
10/100 TX RX FH2
10/100 RX TX FH2
LK/ ACT
PORT PORT
M a g n u m E 4 2 S
P r e m i u m
E d g e S w i t c h
10 F OR
100 A OR
PWR
A L A R M
12 VDC 1 AMP

communication while being installed in temperature un-controlled cabinets and allowing a
provides access for other Ethernet equipment such as motion detectors or will act as a test
cameras may be spread out over many miles in temperature un-controlled locations and
with pan, tilt and zoom (PTZ) controlled through an Ethernet copper port .The premium
port for maintenance personnel with up-link for access to a central LAN and central file
full range of AC and DC power options. The four copper ports at the remote location
deployed to serve as a secure corporate or transportation surveillance system. CCTV
Edge Switches provide two fiber segments for secure long distance (2-40km)
servers.

The ideally suited ES42P with its diversified features, premium rated approvals and cost-
effective solution, make an ideal choice in outdoor environments.
CCTV Camera CCTV Camera
CCTV Camera CCTV Camera
10/100 R X TX FH2
LK/ ACT
1 0/ 10 0
M a gn um E 42 S
P r e m i u m
E d g e S w i t c h
10 F OR
100 A O R
PWR
A L AR M
12 VDC 1 AMP
10 /10 0 TX RX FH2
1 0/1 00 RX TX FH2
LK/ ACT
1 0/ 10 0
M a gnum E 42 S
P r e m i u m
E d g e S w i t c h
10 F OR
100 A O R
PWR
PO RT PORT
12 VDC 1 AMP
A LA R M
CCTV Camera CCTV Camera CCTV Camera CCTV Camera
ES42p in a Outdoor application
LK/ ACT
1 0/ 10 0
1 3 5 7
ACT
F/H
ACT F/H
ACT
F/H
2 4 6 8
PORT PORT
M a g num E 42 S
P r e m i u m
E d g e S w i t c h
F/H
AC T
F/H
ACT F/H
ACT
F/H
LK/ ACT
10 F OR
100 A OR
A L AR M
12 VDC 1 AMP
1 3 5 7 9 11 13 15 17 19 21 23
2 4 6 8 10 12 14 16 18 20 22 24
LK/ ACT
1 0/ 10 0
M a g num E 4 2 S
E d g e S w i t c h
1 00 A OR
PWR
PORT PORT
P r e m i u m
CCTV Camera CCTV Camera
AL A RM
12 VDC 1 A MP
CCTV Camera CCTV Camera
LK/ ACT
1 0/ 10 0
LK/ ACT
PWR
PORT PORT
M a gnu m E 42 S
P r e m i u m
E d g e S w i t c h
10/100 T X R X FH2
10/100 RX T X FH2
1 0 F OR
100 A O R
AL A RM
12 VDC 1 AMP
PWR
PORT PORT
M a gnum E 42 S
P r e m i u m
E d g e S w i t c h
10 F O R
100 A OR
A L AR M
12 VDC 1 AMP

This section describes the installation of the Magnum ES42 Series Edge
clips for panel -
power supply options and media connection.
store and forward switch easily takes care of
transparent half-and full-duplex mode. The
network traffic and can be used as a useful,
Switches, including location, mountings,
All the ES42 Series Switches operate in
economical tool to expand an existing
network.

shelf. Alternatively, metal mounting clips and screws are included for a rugged and secure
The compact and lightweight design of the Magnum ES42 Series allows it to be
easily installed in almost any location. A Velcro strip may be used for mounting the unit
associated cabling. Make sure the unit is installed in a location that is easily accessible to
an AC power outlet or the appropriate DC source and where cooling is not inhibited. The
on a vertical surface such as a wall or cabinet, or for securing the unit on a table-top or
Installation of the Magnum ES42 Series Edge Switches is a simple procedure. The
installation location is dependent upon the physical layout of the Ethernet network and
green Power (PWR) LED must turn ON when power is applied.
mounting in any orientation.


3.2 MC14-TRAY for Rack Mounting of ES42 Series Switches For 19” rack-mounting
available, the MC14-TRAY. The
Edge Switches are mounted with
connectors in the front. Any mix
Switches, a rack-mount tray is
the DC power jack in the back,
of Magnum ES42 series Edge
with the fiber and the RJ-45
of the Edge Switches and/or

3.3 MC14-TR+PS9 and MC14-TR+PS9X2 for Rack Mounting Media Edges The MC14-TR+ PS9 and MC14-TR+PS9X2 are other options for rack mounting the mix of
of the MC14-TRAY are specific to the Magnum products and will not permit other models
eight) ES42 Series Edge Switches, with their power supplies plugged into power strips (not
Edge Switches firmly in place. The beveled-top edge of the units permits the LEDs of each
mount tray. These models come with built-in common universal AC power supply rated at
Media Edges may be placed on a tray, up to a maximum of 8 units. (The mounting spaces
In a typical installation, the MC14-TRAY, 19” rack-mount tray will hold a few (three to
included) in the rear area of the tray. Metal mounting screws in the bottom-front hold the
55 watts at 50°C ambient,9VDC output, and supporting up to 2-3 Switches for MC14- TR+PS9 and 5 units ES42 Series for MC14-TR+PS9X2. The MC14-TR+PS9X2 Model
Magnum 10Mbps and 100Mbps Edge Switches and Media Edges together in a 19” rack-
unit to be viewed for operational status, even when the units are very close together.
to be properly mounted).

has two groups of eight units per power supply. The power supplies have auto-ranging AC
The side-view < here is an example of
TR+PS9, 19” rack-mount tray, holding
supply in the rear area of the tray. (AC
used). Because of the thicker size, only
securing them in the tray and enabling separate removal for service. The dual LEDs permit
eight ES42 units can fit in one MC14-
a few ES42, and 14E Media Edges,
each with their power input plugged
into the built-in common AC power
models of the Edge Switch’s are not
an installation of the model MC14-
PS units that come with the office
Metal mounting screws in the bottom-front hold each of the Edge Switches,
input for use worldwide.
TRAY.

viewing of Edge Switch status from any angle.


spring-loaded with a pull-up latch at the top for easy “snap-on” attachment and removal.
The Magnum ES42 models with “HR” have 24VDC power, and have the DIN-
3.4 DIN-Rail mounting option The Magnum ES42H and ES42P Edge Switches, designed for use in “Factory
Rail-MC2 bracket included and assembled with the MC unit at the factory.
enclosure having DIN Rails
shown alongside the DIN-Rail-
separate item, e.g. Model #DIN-
RAIL-MC2. It comes with four
environments, are available for
mounting hardware is optional
screws to attach the bracket to
and needs to be ordered as a
the MC unit. The rail clip is
DIN-Rail mounting in an
MC2 bracket here ->
The metal DIN-Rail · Floor” Industrial Ethernet


extended temperature (H and P) versions are used for heavy duty industrial applications.
Magnum ES42 Series Switches are power-efficient and can work with an external AC
power supply. Magnum ES42 Series require a nominal 12VDC input version. The
3.5 Power Requirements, Power Supply Types for ES42 Series Switches
info detail is provided in Technical Specs Section 1.1.
The 12V DC power input jack has a plug of 2.5mm,
center +ve , with 6 ft. cord. All the AC power supply
The ES42 Edge Switches provide reliable operation,
The ES42 Series are designed to be used with UL
ES42H or P with 12VDC/ 24VDC/ -48VDC
listed Class II power supplies.

withstand higher temperature environments, and provide the DC power choices to the user
ground. The 9V DC jack is also present. Detail information about the 12 VDC, the 24V DC
only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like).
and the –48V DC is provided in the Technical Specifications Section 1.1.
The various models of DC power type and extended ambient temperature power supplies
The Direct DC (Internal) 12V DC (8 – 15V DC) has a built-in terminal block for +, -,
are numerous and your choice needs to be called out on your order.
to deploy in uncontrolled temperature environments.

3.6 Powering the ES42H and ES42P (DC internal) with 12V, 24V or –48VDC power input

supplied via the jack. Power input from the DC terminal block and the jack and both may
be connected simultaneously for power input redundancy.
of the power input leads. Three DC power models
Each Magnum ES42H/ES42P-Series is
equipped with an internal DC power supply, and
has built-in screw terminals for secure attachment
support a range of power input types. The three
DC power input terminal block choices are for
use with 12VDC, 24VDC or -48VDC power.
Where an AC power adaptor is used, DC is


support the Dual Source 24V input option. An
RIGHT…and sold separately, or a customer-
24VDC power to the ES4H or P unit via the
supplied equivalent) can be used to input
external Dual-SRC-24KIT (SHOWN AT
jack. This is for 24VDC models only.

3.6 continued, DC Power Terminals: “+”, “-”, gnd GND: Terminal for “earth” or ground wire connection to the ES42H chassis
(8-15VDC)
-48VDC
(10-30VDC) (12V)
Power Consumption: 7 watts typical, 9 watts max.
0.4 amp max.(24V DC)
0.2 amp max.(-48V DC)
0.8 amp.(12V DC)
24VDC
Input current:
(8-15VDC)
Contact
Terminal
12VDC
Alarm
(12V)


DC power terminal block on the Magnum ES42H Edge
Switch (as shown in the Figure). The DC terminal block
on the Magnum ES42H is located on the left side of the
posts. The power terminals are identified as positive (+)
and negative (-), and they are floating inside the unit so
that either of the terminals may be grounded by the user
if desired. The chassis is “earth” or ground (GND). The
This section describes the proper connection
of the -48VDC leads (or 24VDC, 12VDC leads) to the
connection procedure is straightforward. Simply insert
unit and is equipped with three (3) screw-down lead

the DC leads to the ES42H’s power terminals, positive (+) and negative (-) screws. The use
and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead
3.8 Connecting Ethernet Media The Magnum ES42-Series Edge Switches can be connected to two media types
i.e. fiber and copper (RJ-45) types, runt at 100BASE-TX, 10BASE-T and 100BASE-FX
only. CAT 5 cables should be used when making 100BASE-TX connections. When the
of Ground (GND) optional; it connects to the ES42H chassis. Ensure that each lead is
securely tightened from the top, as shown on above picture with arrow.
will connect to the post labeled “+ve” and the rest to the “-ve”.
When power is applied, the green PWR LED will illuminate.
The GND can be hooked up at the last.

for single-mode, 9/125 microns cabling should be used. Fiber cabling supports much longer
distance for unshielded twisted pair cabling is 100 meters (328 ft). For fiber port 10BASE-
FL or 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling can be used, whereas
mixed-speed network, since ES42-series switch ports are auto-sensing for either
10 and 100Mbps. Note that the auto-cross function does not operate, if the port is fixed or not supporting auto-negotiation.
ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum
Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45
and 100Mbps) be used whenever possible in order to provide flexibility in a
Twisted Pair (CAT 5) 100BASE-TX RJ-45
Media IEEE Standard Connector
Fiber (Multi-mode) 100BASE-FX ST, SC
Fiber (Single-mode) 100BASE-FX SC, LC
Fiber (Multi-mode) 100BASE-FX MTRJ
cable distance and higher bandwidths as compared to copper wiring.

The following procedure describes how to connect a 10BASE-T or 100BASE-TX
twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and
does not help, ensure that the cable is connected properly and that the device on the
either unshielded or shielded cables and wiring may be used.
other end is powered and is not defective.
shielded twisted pair cables.

LINK is not lit after cable connection, the normal cause is improper cable polarity.
the Receive (RX) port of the remote device. Begin with the color-coded strand of
The following procedure applies to installations using ST-type fiber connectors.
dampened in alcohol. Make certain the connectors are clean before connecting.
This procedure applies to ports using multi-mode ST fiber connectors.
Swap the fiber cables at the fiber connector to remedy this situation.
remote device. Use the non-color coded fiber strand for this.
ports at each end of the fiber optic segment.
the cable for this first TX-to-RX connection.

connectors, i.e., using multi-mode SC and SC single-mode. While connecting
fiber media to SC connectors, simply snap on the two square male connectors
connectors. Single-mode fiber cable has a smaller diameter than multi-mode
fiber cable (9/125 microns for single-mode, 50/125 or 62.5/125 microns for
multi-mode where xx/xx are the diameters of the core and the core plus the
into the SC female jacks of the Fiber connector until it clicks and secures.
When using single-mode fiber cable, be sure to use single-mode fiber port
cladding respectively). Single-mode fiber allows full bandwidth at longer
fiber connectors. Follow the steps listed in Section 3.8.2 above.
The following procedure applies to installations using SC-type fiber
distances, about 20Km with the multi-mode SC.

The following data has been collected from component manufacturer’s (Agilent’s, JDS-
Receiver Sensitivity and Transmitter Power are the parameters necessary to
compute the power budget. To calculate the power budget of different fiber media
Uniphase, stratus, Lucents’) web sites and catalogs to provide guidance to network
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km (SSCX)
installations using Magnum products, the following equations should be used:
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
where the “Cable Loss” for 62.5/125 and 50/125µm (m.m.) is 2.8 dB/km,
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
OPB (Optical Power Budget) = PT(min) - PR(min)
integrators and installers-


-31 9.0 5.5 2.5 2.0 14 12 5 4
mode 20 (0.4) 1310 9/125 -15 -31 14 28 17.5 35
-31 9.0 5.5 3.0 2.0 15.8 12.2 5.5 4.0
mode 40 (0.4) 1310 9/125 -5 -34 27 54 32.5 65
mode 20 (0.4) 1310 9/125 -16 -32 14 28 - -
Mode Std. km Wavel
MST, MSC 100Mb FX Multi-
Std.
ES42-
MTRJ
ES42-
SSCX

When 100Mb operation is agreed and in use, the 10/100 LED is illuminated steady ON and
The copper ports of Magnum ES42-Sereis Edge Switches will function properly
Pulse (FLP) coding for the 100BASE-TX signaling system. When connecting a NIC to the
* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following
with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link
ES42-Series, it may be necessary to reload the NIC drivers on the user device if the NIC
has been communicating with a protocol other than 100BASE-TX (such as 10BASE-T).
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
passive Attenuation.
is OFF, if 10 Mbps traffic.
factors are both applied:

speed, and auto-cross for plug polarity. (See Section 4.2). When the connected device is 10
communicate with 10 Mb and 100Mb users. Magnum ES42 Series units are plug-and-play
The Magnum ES42 Series Edge Switches provide SIX switched ports
users can “communicate” with 100Mbps users as well as other 10 Mbps users through the
Mbps, the ES42s obeys all the rules of 10 Mbps Ethernet configurations. The 10 Mbps
with combination of fiber and copper or copper only. The architecture supports a dual
The switched RJ-45 ports are full- or half-duplex auto-sensing for mode and
switch. Similarly, the 100Mbps traffic obeys the rules of 100Mbps Ethernet, and can
speed switching environment, with standard auto-negotiation capability.
4.0 OPERATION

as occasional multi-cast packets) are forwarded to all ports. The Magnum ES42 Series Edge
Each time a packet arrives on one of the switched ports, the decision is taken to either filter
where it is not needed. Packets needed for maintaining the operation of the network (such
or to forward the packet. Packets whose source and destination addresses lie on the same
Switches operate in the store-and-forward switching mode, which eliminates bad packets
and enables peak performance to be achieved when there is heavy traffic on the network.
devices. There is no software configuring to be done at installation or for maintenance,
port segment will be filtered, constraining them to one port and relieving the rest of the
segment will be forwarded to the appropriate port, and will not be sent to the other ports
network from processing them. A packet whose destination address is on another port
addresses, and are suitable for use in large networks. They are self-learning, so that as
The Magnum ES42 Series units have address table capacity of 2K node
even for the LLL ports. The internal functions of both are described below.
Switching, Address Learning

An address-aging algorithm causes least-used addresses to fall out in favor of
new frequently-used addresses. To reset the address buffer, cycle power down-and-up.
mode according to the IEEE 802.3u standard. No crossover cables are needed on RJ-45
switches where the switch manager fixes the port settings via software, and the result of
advertises its capability for 10 or 100 Mbps speed and F/H duplex mode, and the device
nodes are added or removed or moved from one segment to another, the ES42- Series
4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing The RJ-45 ports support auto-cross (MDI or MDIX) in the auto-negotiation
port, when connecting the ES42 to other unmanaged switches, legacy hubs, managed
switches, media-converter etc. Please note that there can be conditions with managed
the auto-negotiation is changed in the managed switch by the manager commands. In
negotiation and which go to the default state accordingly). The Magnum ES42 Switch
such cases, the 10/100 speed or the F/H mode may be affected, but auto-cross in the
When an RJ-45 cable connection is made, and each time LINK is enabled,
auto-negotiation takes place (except for legacy products, which do not have auto-
ES42 will still work. The auto-cross function cannot be disabled.
switch automatically keeps up with node locations.

at the other end of the cable should similarly advertise / respond. Both sides will agree
to the speed and mode to be used per the IEEE 802.3u standard. Depending upon the
devices connected, this will result in agreement to operate at either 10 Mbps or
100Mbps speed, and full- or half-duplex mode.

LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will turn
off in the event connectivity is lost between the ends of the twisted pair segment
copper port only. For the model 4copper +2 fiber or 5copper +1fiber,(e.g ES42H-
or a loss of power occurs in the unit or remote device. The Link ports are also
represented by LA1, LA2, LA3…LA6. (Steady On or steady Off indicates no
10/100 Steady ON for 100Mb speed, OFF for 10Mb speed per port (copper ports) F/H (FH1, FH2) Steady ON for Full duplex (F/D) mode, OFF for Half duplex (H/D)
all copper 10/100 ports model (e.g ES42-d), the LEDs 10 or 100 denotes for
PWR Illuminates GREEN to indicate power applied.
ff-Hd) the F or H denotes for fiber port only.
mode per port (For fiber port only)
Receive Activity).

block for Alarm Contacts is part of the Power Input panel in the Magnum ES42s case. The

The two screws Alarm Contacts feature, standard on Magnum ES42H and P,
provides Normally Closed (NC) contacts to which the user can attach one sets of status
monitoring wires at the green terminal block. When this option is present, the terminal
when there is power on the main board inside of the
condition or by the failure of the power supply inside
ES42. This provides a “Hardware operated Alarm”
DC power input connection is in the same panel.
The NC Alarm Contact is held close
because the NC contacts will open when internal
power is lost, either from an external power down
Useful info about Alarm Contacts in
of the Magnum ES42 Switch.
ES42H and ES42P:

Should problems develop during installation or operation, this section is intended
to help locate, identify and correct these types of problems. Please follow the suggestions
consistently high performance in all network environments. The installation of Magnum
ES42 Series 10/100 Mb/s Switches is a straightforward procedure (see INSTALLATION,
listed below prior to contacting your supplier. However, if you are unsure of the
All Magnum Ethernet products are designed to provide reliability and
Section 3.0); the operation is also straightforward and is discussed in Section 4.

not performing as expected, do not attempt to repair the unit; instead contact your supplier
5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back
procedures described in this section or if the Magnum ES42 Series 10/100 Mb/s Switch is
to the Installation Section of the applicable chapter of this manual. Also
impaired during installation. (About 90% of network downtime can be
connected and the cables/wires have not been crimped or in some way
check to make sure that the various components of the network are
attributed to wiring and connector problems.)
for assistance or contact GarrettCom Customer Support.
interoperable.

the problem device is replaced with a known good device. Verify whether or
functioning and appropriate electrical outlet. Use the PWR LEDs to verify
Loop test to test the fiber transceiver is functional or not. Use a short patch
receive to the fiber port transceiver. If the Link Led turns solid green, then
not the problem is corrected. If not, go to Step 6 below. If the problem is
cable of fiber and connect one end of cable to transmit and other end of
ES42-Series unit. Be certain that the AC power cord is plugged into a
ES42 Series 10/100 Mb/s switch product, it is recommended that
the fiber port is functional and working.
each unit is receiving power.

d. Any particular application that, when used, appears to create the problem;
corrected, the Magnum ES42 Series Switch and its associated
of the Magnum ES42 Series 10/100 Mb/s Switch unit or if
unknown, contact GarrettCom, Inc by fax, phone or email -
Please be prepared to provide the following information.
b. Situations/Environment when the problem occurs;
c. The components/devices involved in the problem;
(support@garrettcom.com) for assistance.
a. The nature and duration of the problem;
cables are functioning properly.

including Convenient computers, workstations, terminals and printers; plus, the
Include the date(s) that you purchased the products from your supplier.
various network media types being used, along with diagram of network setup.
All returns for repair must be accompanied by a Return Material Authorization
to the occurrence of the problem. Any changes to system administration
(RMA) number. To obtain an RMA number, please use this URL -
procedures should all be noted in this record.

GarrettCom will carefully test and evaluate all returned products, will repair products that
are under warranty at no charge, and will return the warranty-repaired units to the sender
https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.
Failure symptoms, including a full description of the problem.
Name and phone number of your contact person.
Packing List Number (or Sales Order Number)
Please have the following information readily available:
Name of your company / institution
Serial Number (or Invoice Number)
Your shipping address · Date of installation · Product name

container if available. Units should be wrapped in a "bubble-wrap" plastic sheet
details). However, if the problem or condition causing the return cannot be duplicated by
GarrettCom reserves the right to charge for the testing of non-defective units
under warranty. Testing and repair of product that is not under warranty will result in a
Should you need to ship the unit back to GarrettCom, please follow these instructions:
with shipping charges prepaid (see Warranty Information, Appendix A, for complete
No Problem Found.
GarrettCom, the unit will be returned as:
customer (user) charge.

or bag for shipping protection. (You may retain all connectors and this
This material may cause electro-static shock damage to the unit.
Attn.: Customer Service
Installation Guide.)

During this warranty period, GarrettCom will repair or, at its option, replace components in
has been damaged by misuse, misapplication, or as a result of service or modification other
Please complete the warranty card as this acts as a product registration, and mail
This warranty will not be effective if, in the opinion of GarrettCom, the product
GarrettCom, Inc. warrants its products to be free from defects in materials and
workmanship for a period of three (3) years from the date of shipment by GarrettCom.
the products that prove to be defective at no charge other than shipping and handling,
than by GarrettCom. GarrettCom reserves the right to make a charge for handling and
inspecting any product returned for warranty repair which turns out not to be faulty.
provided that the product is returned pre-paid to GarrettCom.
it to GarrettCom within two weeks of your purchase.