Installation and User Guide


Printed in the United States of America.
reproduced without prior written permission from GarrettCom, Inc.
Copyright 2001 GarrettCom, Inc. All rights reserved. No part of this publication may be
trademark of GarrettCom, Inc.
GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a registered
UL is a registered trademark of Underwriters Laboratories
NEBS is a trademark of Telcordia Technologies
Ethernet is a trademark of Xerox Corporation
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (012/01)
DS80C, consult Section 5, Troubleshooting, of this User Guide.
all warranties null and void. If problems are experienced with a Magnum DS80F or
serviceable parts. Attempted service by unauthorized personnel shall render any and
Installation and User Guide
Trademarks

whatever measures may be required to correct the interference.
likely to cause interference, in which case the user at his own expense will be required to take
operated in a commercial environment. Operation of this equipment in a residential area is
FCC rules, which are designed to provide reasonable protection against such interference when
a Class A computing device in accordance with the specifications in Subpart J of Part 15 of
interference to radio communication. It has been tested and found to comply with the limits for
and used properly, that is in strict accordance with the manufacturer's instructions, may cause
Please use the following mailing address, phone and fax numbers or Internet address.
Contacting GarrettCom, Inc.
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
This equipment generates, uses and can radiate frequency energy and if not installed
Radio Frequency Interference Statement
GarrettCom, Inc.
Federal Communications Commission · Fremont, CA 94539 · 213 Hammond Avenue

4K-Series Switches, 100 & 10Mbps, copper ports with optional fiber port, with auto-negotiating full switching performance. Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed and mixed-media types, full switching performance. “Outdoor” Ethernet Switch, for temperature uncontrolled locations 6 10/100 and 2 100Mb fiber ports, can be connected in strings Mixed-Media Fiber Hub, 16-port Stackable, 10/100 auto-sensing Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing Stackable Hubs, SNMP Optional 10Mb series and 100Mb series, both w/ optional port modules Personal Switches, 10/100Mb 8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb 8-port, with two switched ports (1 fiber built in) Personal Hubs, 10Mb series 8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series All media combinations, incl. fiber ST, SC, mm., single mode The “X-line” of configurable MiXed Media products: Stackable Concentrators, SNMP optional, 13-Ports Mini-Concentrators, 7 Ports, Repeaters, 2-Ports Repeater Port Modules (RPMs), 6 types for Ethernet media Bridge Port Modules (BPMs), 4 types, for segment isolation Fan-Outs, 10Mb series 2, 4 and 8 Port Model Transceivers, 10Mb and 100Mb series 10Mb Mini-Transceivers and Coax Models, All Types - Dec, 01
ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc.offers the premium-quality Magnum line of Ethernet LAN connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Carrier Class, Industrial Grade and OEM applications where reliability is a primary consideration.
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)


Power Supply (External) Input: 95-125 vac at 60Hz for “-d” Models 200-250 vac at 50Hz for “-i” Models, which have IEC power cable connector in the external power unit. Output: 5VDC, 2Amps Polarity: center positive, shell negative Power Consumption: 8 watts typical, 10 watts max.
Packet-Processing Between Domains Filtering and Forwarding Rate from 100Mbps ports: 148,800 pps max Filtering and Forwarding Rate from 10Mbps ports: 14,880 pps max. Processing type: Store and Forward Auto-learning: 8K address table, shared for all traffic domains Packet buffers: 512KB, dynamically shared on all domains Latency (not including packet time): 100 to 10Mbps: 5µs 10 to 100Mbps: 5µs Path Delay Value: 50 BT on all ports
Performance of Dual-Speed Ports When a port is operating at 100Mbps: Data Rate: 100Mbps When a port is operating at 10Mbps: Data Rate: 10Mbps Partitioning: Enforced after 63 consecutive collisions Auto-reconnect: Occurs after one packet of error-free reception
1.1 Technical Specifications
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
Maximum Ethernet Segment (or Domain) Lengths 10BASE-T (Unshielded twisted pair) - 100 m (328 ft) 100BASE-TX (CAT 5 UTP) - 100 m (328 ft) 100BASE-FX, half-duplex: (multi-mode) - 412 m (1350 ft) 100BASE-FX, full-duplex: (multi-mode) - 2.0 km (6,562 ft) 100BASE-FX, half-duplex: (single-mode) - 412 m (1350 ft) 100BASE-FX, full-duplex: (single-mode) - 20.0 km (65,620 ft) 100BASE-FX, full-duplex: (single-mode, long) - 40.0 km (131,240 ft)
Operating Environment Ambient Temperature: 32ºF to 104ºF (0ºC to 40ºC) Storage Temperature: -5ºC to 160ºF (-20ºC to 70ºC) Ambient Relative Humidity: 10% to 95% (non-condensing)
Network Standards 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3u

LED Indicators PWR: Steady On when power applied ERROR: Self-test at power up failed SPEED (with LINK ON): ON = 100Mbps; OFF = 10Mbps LINK/ACT: Steady On for LINK with no traffic, blinking indicates port is transmitting / receiving. F/H (for port 1SW and 2SW only): ON = full-duplex, OFF = half-duplex
Packaging Enclosure: Rugged high-strength sheet metal. Metal mounting clips included. Suitable for wiring closet shelf, wall or desktop mounting. Dimensions: 1.25 in H x 6.75 in W x 5.0 in D (3.2 cm x 17.1 cm x 12.7 cm) Weight (of hub unit): 1.0 lb. (455 g.) Weight (of power supply unit): 1.0 lb. (455 g.) Cooling method: Convection
See Section 4.3 for details.
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
Up-Link, Port # 1 SW
Network Cable Connectors - for eight RJ-45 shielded female ports and 1 fiber port
UL Listed (UL 1950), cUL, CE Emissions: meets FCC Part 15, Class A
for auto-negotiation, and for fiber it forces half-duplex mode.
mode at 100Mb. In the “H” position, it causes half-duplex mode to be advertised
802.3u auto-negotiation session on port 1SW. For fiber, it forces full-duplex
In the “F” position, it causes full-duplex mode to be advertised for the standard
Ports 1SW and 2SW (the switched ports) have a common “F-H” manual switch.
fixes port 2 at Full 100Mb. In the “A” position, port 2 is set at auto-negotiation
Port 2SW (a switched port) has a “FF-A” manual switch. In the “FF” position, it
connection to a central switch or to another DS80F, DS80C (or equal) unit.
Port 1SW (switched RJ-45) has a manual crossover (MDIX up-link) switch for
Power Input Voltage: 36 to 70 VDC (auto ranging), “-, GND, +” Power Consumption: 8 watts typical, 10 watts max.
Agency Approvals · Manual Switch

1.2 Ordering Information Magnum DS80F -10/100 Dual-Speed Personal Hubs with a 100Mb Fiber Port
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
GarrettCom, Inc. reserves the right to change specifications, performance characteristics and / or model offerings without notice.
230vac 50Hz.
Use “-d” suffix for external power supply at 115vac 60Hz; use “-i” suffix for external at
fiber connector. Magnum DS80F-MTRJ-d, or -i: Same as DS80F but with multi-mode MTRJ-
fiber connector. Magnum DS80F-SSC-d, or -i: Same as DS80F but with single-mode SC-type
External power supply.
The internal switch has 8K node addresses and 512KB packet buffers.
moving between the two switched ports, and among the 10/100 user ports.
ports. Includes store-and-forward switching that filters and forwards data
10/100 N-way switched ports and six half-duplex 10/100 auto-negotiating
buffers. External 115vac 60Hz power supply.
The internal switch has 8K nodes address table and 512KB packet
moving between the two switched ports, among the 10/100 user ports.
ports. Includes store-and-forward switching that filters and forwards data
“N-way” switched RJ-45 port, and six half-duplex 10/100 auto-negotiating
duplex 100Mbps switched fiber port (multi-mode SC-type connector), one
type fiber connector.

specific return procedures.
return the unit, use the original shipping container. Refer to Chapter 5, Troubleshooting, for
to Garrett Communications as soon as possible.
validate the product warranty, please complete and return the enclosed Product Registration Card
Be sure to keep the shipping container should you need to ship the unit at a later date. To
This package should contain:
included.
the contents of this package for any signs of damage and ensure that the items listed below are
notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect
2.1 Inspecting the Package and Product
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
In the event there are items missing or damaged, contact your supplier. If you need to
Remove the Magnum DS80F or DS80C Dual-Speed Hub from the shipping container.
1 Product Registration Card
1 Installation and User Guide
1 Set of metal clips and screws for secure shelf or wall-mounting
1 External Power Supply, 5VDC from either 115v 60Hz or 230v 50Hz
1 Magnum DS80F Dual-Speed Hub with a Fiber Port or DS80C with all copper
Examine the shipping container for obvious damage prior to installing this product;
ports.

time without impairing the operation of the other ports and connected devices.
LINK enable, see Section 4.2 for details), allowing the connected devices to change speed at any
the speed of other ports. The automatic per-port speed-sensing is always ready (it takes place at
domain, and can also change from one traffic domain to the other at any time without affecting
traffic and one for the 10Mbps traffic.
are separate internal traffic domains in Magnum DS80F & DS80C hubs, one for the 100Mbps
high-performance workplace servers or to cascade to another DS80-series for expansion. There
no media converter is required), the switched RJ-45 port can be used at 100Mb. FDX for
connected device. While the switched fiber port is typically for a backbone connection (note –
either 100Mbps or 10Mbps Ethernet signals, adapting to match the highest speed of the
half- or full duplex selection on the two switched ports, see sections 4.3 and 4.4.
switched ports with “N-way” capability and six half duplex 10/100 auto-negotiating ports. For
RJ-45 ports. The DS80C “Copper” model has been designed with all eight RJ45 ports, two
switched fiber port, one “N-way” switched RJ-45 and six half-duplex 10/100 auto-negotiating
convenience of dual-speed 10/100 copper ports for workplace LAN connections.
all copper ports, offer the flexibility of 100Mbps switched fiber link upstream with the
2.2 Product Description - General
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
PWR 1 2 3 4 5 6 7 8 9 1 0 11 12
10Mbps Hub 100Mbps Hub
DS80F & DS80C ports #3 to 8 can connect into either the 100 or the 10Mbps traffic
Ports #3 to 8 can independently identify (via IEEE 802.3u auto-sensing) and accept
Magnum D80F “Fiber” models have been designed with one full-duplex 100Mbps
The DS80F Dual-Speed Personal Hubs with a Fiber Port, and the DS80C model with
8000E 9 10 11 12 Stackable
PWR 1 2 3 4 5 6 7 8 Magnum
PORTS 1SW 2SW 3 4 5 6 7 8
= X
UPLINK 3 4 5 6 7 8 1SW
2SW
12V, 1.5Amps
Magnum DS80 Dual Speed Personal Hub

ports 1SW and 2SW have full/half (F/H ON for full duplex) duplex indicators.
Link and Activity (LINK/ACT) LEDs indicating traffic, and speed (ON for 100Mbps). Switched
(PWR) and ERROR (self-test at power up failed) indicators for the unit. For each port, there are
with selectable Fullfixed- and Auto-negotiation (FF-A) capability. See section 4.4.
2.2.2 Magnum DS80C chassis with all RJ-45 Copper ports
supply housing.
250vac at 50Hz for “-i” models that have IEC power cable connector in the external power
The external power supply is 5VDC at either 95 - 125vac at 60 Hz for “-d” models or 120-
“jack” is in the left rear of the chassis. Rear View Magnum DS80-Series
have full-half (F-H) duplex indicators.
100Mbps). Switched ports 1SW and 2SW
indicating traffic, and speed (ON for
failed) indicators for the unit. For each port, there are Link and Activity (LINK/ACT) LEDs
of all ports are mounted on the top. There are power (PWR) and ERROR (self-test at power up
ports only and the RJ-45 connector is inoperative at all times. LEDs to indicate operating status
eight RJ-45 twisted-pair ports and one 100Mbps fiber port. Port #2SW always supports fiber
houses one main PC board. The power supply unit is external. The front side of the chassis has
2.2.1 Magnum DS80F chassis with fiber ST or SC (mm or sgl. mode) connector
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)

Fiber ST above, fiber SC at right
PORTS 1SW 2SW 3 4 5 6 7 8
LEDs to indicate operating status of all ports are mounted on the top. There are power
PORTS 1SW 2SW 3 4 5 6 7 8
The DC power plug connector or
The Magnum DS80F chassis
UPLINK 3 4 5 6 7 8 1SW
2SW
12V, 1.5Amps
Magnum DS80 Dual Speed Personal Hub

PORTS 1SW 2SW 3 4 5 6 7 8
The 1SW and 2SW ports are switched ports
chassis has eight RJ-45 twisted-pair ports.
supply unit is external. The front side of the
houses one main PC board. The power
GARRETT
PORTS 1SW 2SW 3 4 5 6 7 8
= X
UPLINK 3 4 5 6 7 8 1SW
2SW
The Magnum DS80C chassis
12V, 1.5Amps
Magnum DS80 Dual Speed Personal Hub

100Mbps Fiber port, ST-type mm or SC type(single-mode or multi-mode)
2.4 Fiber port for DS80F – Series
the auto-sensing feature will cause the connecting link to operate at 100Mbps speed.
100Mbps or 10Mbps devices. When the up-link port is used to cascade two DS80F series hubs,
device. The up-link feature operates the same, whether Port # 1SW is connected to either
capable of full- and half-duplex mode auto-sensing, based on the capability of the connected
switch. (See Section 4.6 for more details about up-link). Unlike ports #3 to 8, port #1SW is
the port’s twisted pair cable to cascade to another shared hub, switching hub port or 10/100Mbps
2.3 Up-link Port 1SW for Cascading
LED will be OFF when 10Mbps signals (or no signals) are detected.
device. The Speed LED will illuminate (GREEN) when 100Mbps signals are detected; the Speed
auto-sensed speed detection, and the resulting connectivity to either a 10Mbps or 100Mbps
any full-duplex operation.
auto-negotiation technique, on ports #3 to 8, is only for 10/100 speed, and does not provide for
speed, then the operation on that DS80F and DS80C port will be at 10Mbps. Of course, the
at 100Mbps. If the connected device does not positively indicate that it is capable of 100Mbps
device or node indicates that it is capable of 100Mbps speed, then operation on that port will be
accordance with the standards of the IEEE 802.3u auto-negotiation standard. If the connected
the other ports. Speed-sensing is performed by the DS80F and DS80C’s electronics in
2.2.3 10 / 100 Speed Auto-sensing
supply housing.
120-250vac at 50Hz for “-i” models that have IEC power cable connector in the external power
DS80F. The external 5VDC power supply is for either 95 - 125vac at 60 Hz for “-d” models or
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
The Fast Ethernet fiber switched port on the Magnum DS80F is set to operate at fixed
The unit has an up-link Port # 1SW, located on the left-front side of the hub. It enables
The per-port 10/100Mbps Link/Activity LEDs on the top panel indicate the result of
Ports #3 to 8, RJ-45 twisted pair HDX, support auto-sensing for speed independent of
The DC power plug connector or “jack” is in the left rear of the chassis, like the
UPLINK
= X
UPLINK F H
F H
= X
Tx Rx · Tx Rx

indications of operating conditions.
made with the device at the other end of the cable in order for these LEDs to provide valid
The F/H indicates full-duplex when ON, when it is OFF, operation is half-duplex.
receiving. The SPEED LED is ON for 100Mbps and OFF for 10Mbps (when LINK is made).
(LK/ACT) is steady ON to indicate LINK, blinking indicates the port is transmitting and
advertised for RJ-45 auto-negotiation, and for fiber it forces half-duplex mode.
duplex mode at 100Mb. When set in the “H” position, it causes half-duplex mode to be
standard 802.3u auto-negotiation session on RJ-45 ports, and for the fiber port, it forces full-
manual switch. When set in the “F” position, it causes full-duplex mode to be advertised for the
distances for installation versatility.
connection (no media converter is required!) and supporting long (up to 40km) fiber cable
fiber port is a switched port and performs as a domain, providing a high bandwidth backbone
100Mbs speed at all times with manually selected full- and half-duplex capability. The 100Mbps
a multi-mode ST, multi-mode SC or single-mode SC connector. The 100Mb fiber port will run at
100Mb speed for guaranteed high performance. The DS80F’s fiber port is factory-built as either
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
A fiber cable must be connected to the 100Mb port and a proper link (LK lit) must be
On Magnum DS80F units, there are three LED’s for the switched ports. One
Ports 1SW and 2SW (the switched ports) have a common “F - H” user-selectable

2.5 Features and Benefits
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
is a choice of external power supplies, for either 115vac or 230vac.
wall outlet. They come in a durable metal enclosure for table-top or wall-mount. There
offices and labs, or virtually any workspace location within reach of a standard AC
The compact packaging of Magnum DS80F & DS80C’s allows them to be installed in
without affecting operations.
tables are self-learning, enabling users to change port connections or 10/100 domains
packets from each domain that are needed on the other domains. Internal address
The Magnum DS80F & DS80C operates as a hardware switch, only forwarding those
expansion. An up-link switch is built in for port #1SW.
another hub cascaded, or a switched “stack” connection to another DS80F, DS80C for
The (1SW) 10/100 switched RJ-45 port #1 can support a local server, a power user,
different models, including 100Mb multi-mode, single-mode, and single-mode long.
converter is required. Different fiber connector types and modes are supported by
buildings and classrooms where fiber is built into the infrastructure. No media
from the local users upstream to the rest of the network. This is ideal in office
The F/H selectable 100Mbps fiber port(2SW) connects to a “future-proof” fiber cable
domains.
switching provides full bandwidth in each domain, unaffected by local traffic on other
allowing all connected devices to communicate to each other. High performance
the two switched ports (#1SW and #2SW) and the half-duplex 10/100 ports (#3 to 8),
DS80F’s and DS80C’s have internal switches for filtering/forwarding traffic among
enable and complies with IEEE 802.3u, providing interoperability with other products.
and 100Mbps users can be connected to the ports. Speed-sensing occurs at LINK
operate at either 10 or 100Mbps, independently of the other ports. Any mix of 10Mbps
at 10Mbps and one at 100Mbps -- in one physical box. Half-duplex ports #3 to 8
Magnum DS80F & DS80C Dual-Speed 10/100 hubs combine two logical hubs -- one
Small enclosure enables use in offices, labs and classrooms
Installation is “Plug and Play”, operation is transparent to software
Switched RJ-45 N-way port #1 for a high speed “copper” connection
DS80F’s switched fiber-built-in 100Mb port #2, for “backbone” connectivity
Internal switches connects all of the ports and users
Supports 10 or 100Mbps network connections on RJ-45 ports # 3 to 8

domain, so overall performance of the network is sustained at the highest possible level.
auxiliary media converter unit. The 100Mbps traffic does not use the bandwidth of the 10Mbps
performance data transfers, and provides fiber connectivity built-in rather than needing an
Ethernet users. The 100Mb fiber port on the DS80F can be used for accommodating high
moved to a DS80F dual-speed port, and will automatically operate at the higher speed.
10Mbps network without having to change it. Nodes that are capable of 100Mbps speed can be
port of the DS80F. This allows a simple plug-and-play addition of 100Mbps ports to an existing
change speed at any time without affecting network operation or impacting other users.
full-duplex switched ports capability makes the required setup simple. Any attached node can
Magnum DS80F Personal Hub serves this requirement economically. The two 1SW and 2SW
need a high bandwidth backbone for access to a central LAN and central file servers. A
some users and utility devices (such as print servers) run at 10Mbps. High performance users
office with multi-server and mixed-speed requirements. Some users operate at 100Mbps, and
Example 1. Magnum DS80F In this example, a Magnum DS80F Personal Hub serves a small
used copper connectivity to small user groups in offices, classrooms and labs.
2.6 Applications
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
The 1SW full duplex 100Mbps switched port can support a local server for Fast
Where there is existing 10Mbps hubs and users, they can easily be cascaded into any

The DS80F & DS80C are designed to bring future-proof fiber connectivity and highly
provides a Fast Ethernet fiber backbone for access to the central LAN.
PORTS 1SW 2SW 3 4 5 6 7 8
12V, 1.5Amps
100Mbps fiber · 10 Mbps Workgroups

ethernet backbone for expanding the network.
boosted the personal hub with its own switched 100Mbps or 10Mbps domain and provide a Fast
traffic and always operates at the higher speed. The switching capability at 1SW and 2SW
with reliability.
or impacting other users. The two DS80C cascaded together solve the requirement economically
file servers. Any attached node can change speed at any time without affecting network operation
High performance users need a high bandwidth backbone for access to a central LAN and central
operate at 100Mb as well as at 10Mb and utility devices (such as print servers) run at 10Mbps.
office with multi-server, print server, internet access and mixed-speed requirements. The users
In this example, two of the Magnum DS80C Personal Hub cascaded together to serve a small
this Hub to connect at Full duplex to any non-Auto-negotiating Switch using the “FF” mode.
bandwidth uplink solution for expansion. The “FF-A” manual switch options for port 2SW allow
100Mbps users and the switching full duplex capability on 1SW and 2SW provides a high
solution at copper port. The Dual-Speed functions supports a mixed environment of 10Mbps and
Full duplex switching capability, the DS80C provides a very economical high Bandwidth
volume and are forced to scale network quickly and cost effectively. Due to its 1SW and 2SW
Example 2. Magnum DS80C
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)

The Dual-Speed characteristic allows the DS80C to support the 10Mbps and 100Mbps
The Magnum DS80C fits very well with small business seeing a growth in users
PORTS 1SW 2SW 3 4 5 6 7 8
PORTS 1SW 2SW 3 4 5 6 7 8
12V, 1.5Amps
Fast Ethernet backbone.
Magnum DS80C Dual Speed

is also recommended that the brackets be attached to two opposite corners of the unit. When
for attaching mounting bracket to wall (e.g wood screw, self-tapping screw, machine screw). It
brackets (and screws) to allow the unit to be
Personal Hub is shipped with two metal mounting
3.1.2 Wall (or vertical surface) mounting
scratching finished surfaces.
table-top or any suitable horizontal surface, and has four rubber feet to provide stability without
3.1.1 Table-Top or Shelf Mounting
top surface to visually monitor the status LEDs.
protect it from accidental damage in a lab or workplace setting. Maintain an open view of the
DS80F & DS80C site. The rugged metal case of the Magnum DS80F & DS80C will normally
Metal wall-mounting clips are included with the unit.
and it can also be either shelf- of wall-mounted (see mounting instructions in 3.1.2 below).
compact size of the unit allows it to be conveniently placed in an office, classroom or lab area,
on the physical layout of the network. Typically the hub is located in a workplace site. The
3.1 Locating Magnum DS80F & DS80C Dual-Speed Hubs
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
GARRETT
PORTS 1SW 2SW 3 4 5 6 7 8
Each Magnum DS80F and DS80C
The Magnum DS80F & DS80C Dual-Speed Personal Hub can be easily mounted on a
Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum
The location of a Magnum DS80F & DS80C Dual-Speed Personal Hub is dependent
This chapter provides instructions for installing Magnum DS80F and DS80C hubs.
Magnum DS80 Dual Speed Personal Hub
recommended to use appropriate # 4 screws
the bracket to the mounting surface. It is
the bracket. A user-supplied screw attaches
DS80F and DS80C through the round hole of
for each bracket and attaching to the Magnum
metal hub case using one of the metal screws
position. The brackets are attached to the
mounted in nearly any desired orientation or
Error · Power · Speed Link/Act F/H

shielded twisted pair cables.
twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and
Media IEEE Standard Connector Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45 Twisted Pair (CAT 5) 100BASE-TX RJ-45 Fiber (Multi-mode) 100BASE-FX ST Fiber (Multi-mode) 100BASE-FX SC Fiber (Single-mode) 100BASE-FX SC Fiber (Multi-mode) 100BASE-FX MTRJ NOTE : It is recommended that high quality CAT. 5 cables (which work for both 10Mbps and 100Mbps) be used whenever possible in order to provide flexibility in a mixed-speed network, since dual-speed ports are auto-sensing for either 10 and 100Mbps. Note that the auto-sensing function does not sense the cable type. 3.2.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded)
much longer cable distance and higher bandwidths as compared to copper wiring.
used, whereas for single-mode, 9/125 microns cabling should be used. Fiber cabling supports
(328 ft). For fiber port 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling can be
used. In either case, the maximum distance for unshielded twisted pair cabling is 100 meters
making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be
i.e. 100BASE-TX and 10BASE-T, however, DS80F can be connected to the following three
3.2 Connecting Ethernet Media
for the rubber feet.
properly attached, the brackets will extend slightly below the base of the unit to allow clearance
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used. 2. Connect the other end of the cable to the corresponding device. 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established. If this does not help, ensure that the cable is connected properly and that the device on the other end is powered and is not defective. 4. For Port # 1SW, if the LINK LED is not illuminated, move the switch which has a cross- over or up-link for linking to another hub.
The following procedure describes how to connect a 10BASE-T or 100BASE-TX
The Magnum DS80C Dual-Speed Personal Hub can be connected to two media types

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget. To calculate the power budget of different fiber media installations using Magnum products, the following equations should be used: OPB (Optical Power Budget) = PT(min) - PR(min) where PT = Transmitter Output Power, and PR = Receiver Sensitivity
3.2.5 Power Budget Calculations for DS80F Fiber Media
Follow the steps listed in Section 3.2.2 above.
longer distances, about 20Km with the multi-mode SC.
core and the core plus the cladding respectively). Single-mode fiber allows full bandwidth at
single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the diameters of the
Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (9/125 microns for
3.2.4 Connecting Single-Mode Fiber Optic
3.2.3 Connecting Fiber Optic SC-type, "Snap-In"
3.2.2 Connecting Fiber Optic ST-type, “twist-lock” The following procedure applies to installations using ST-type fiber connectors. This procedure applies to ports using a multi-mode ST fiber connectors. 1. Before connecting the fiber optic cable, remove the protective dust caps from the tips of the fiber connectors. Save these dust caps for future use. 2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue dampened in alcohol. Make certain the connectors are clean before connecting. Note: One strand of the duplex fiber optic cable is coded using color bands at regular intervals; you must use the color-coded strand on the associated ports at each end of the fiber optic segment. 3. Connect the Transmit (TX) port (light colored post) on the Magnum Fiber port to the Receive (RX) port of the remote device. Begin with the color-coded strand of the cable for this first TX-to-RX connection. 4. Connect the Receive (RX) port (dark colored post) to the Transmit (TX) port of the remote device. Use the non-color coded fiber strand for this. 5. The LINK LED on the front of the fiber connector will illuminate when a proper connection has been established at both ends (and when power is ON in the unit). If LINK is not lit after cable connection, the normal cause is improper cable polarity. Swap the fiber cables at the fiber connector to remedy this situation.
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
connectors into the SC female jacks of the Fiber connector until it clicks and secures.
using multi-mode SC and SC single-mode.
When connecting fiber media to SC connectors, simply snap on the two square male
The following procedure applies to installations using SC-type fiber connectors, i.e.,
The same procedures as for multi-mode fiber apply to single-mode fiber connectors.
When using single-mode fiber cable, be sure to use single-mode fiber port connectors.

supply, and has a jack for the DC power cord in the rear. A lightweight DC power cord for
3.3 Powering the Magnum DS80F and DS80C
no traffic or if 10Mbps traffic.
100Mb operation is agreed and in use, the SPEED LED is illuminated steady ON. It is OFF if
has been communicating with a protocol other than 100BASE-TX (such as 10BASE-T). When
DS80F or DS80C, it may be necessary to reload the NIC drivers on the user device if the NIC
Link Pulse (FLP) coding for the 100BASE-TX signaling system. When connecting a NIC to the
properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast
3.2.6 Connections to NICs which support Auto-Negotiation, RJ-45 ports
The following data has been collected from component manufacturer’s (HP’s and Siemens’) web sites and catalogs to provide guidance to network designers and installers.
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] where the “Cable Loss” for 62.5/125 and 50/125µm (m.m.) is 2.8 dB/km, and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
Long Reach 100Mb FX
DS80FMST, MSC
Each Magnum DS80F and DS80C Personal Hub is provided with an external power
The copper ports of Magnum DS80F and DS80C Dual-Speed Hubs will function
Std. Mode
Std. km fdx (hdx)
40 (0.4) 1300 9/125 -5 -34 29 58
2 (0.4) 1300 62.5/125 50/125 -20 -23.5
20 (0.4) 1300 9/125 -15 -31 14 28 17.5 35
2 (0.4) 1300 62.5/125 50/125 -20 -23.5
Cable Size µm
X’mitr Output PT , dB
R’cvr Sens. PR ,dB
9.0 5.5 3.0 2.0 15.8 12.2 5.5 4.0
9.0 5.5 2.5 2.0 14 12 5 4
Worst* distance Km, fdx
typical* distance Km, fdx

supplied AC power cord with a convenience power outlet plug.
The 230vac version has a small transformer integral with an IEC-type power plug for a user-
power outlet plug, and a lightweight DC power cord to the applicable power jack on the hub.
AC power system. The 115vac version has a small transformer integral with a convenience
that have IEC power cable connector in the external power unit.
power of 115vac at 60Hz for “-d ” models, and other version of 230vac at 50 Hz for “-i ” models
types; one version for AC input
environments and comes in two
DS80C power supply supports
applied, the green PWR LED will illuminate.
into the matching rear power jack of the DS80F and DS80C Personal Hubs. When the power is
5V, 2.0 amps is supplied with each unit. The small DC power cord from the power supply plugs
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
Examine the power supply to make sure the version you have is the right type for your
Each Magnum DS80F and
PORTS 1SW 2SW 3 4 5 6 7 8
Magnum DS80F Dual Speed
12V, 1.5Amps

when there is heavy traffic on the network.
switching mode, which eliminates bad packets and enables peak performance to be achieved
packets) are forwarded to all ports.
Packets needed for maintaining the operation of the network (such as occasional multi-cast
forwarded to the appropriate port, and will not be sent to the other ports where it is not needed.
processing them. A packet whose destination address is on another port segment will be
segment will be filtered, constraining them to one port and relieving the rest of the network from
filter or to forward the packet. Packets whose source and destination addresses on the same port
Switching, Filtering and Forwarding
internal functions of both are described below.
for the switched ports can be done through a switch accessed from the front of the unit. The
settings are user options for UP-LINK on RJ-45 port #1 SW. Half / Full duplex mode selection
configuring to be done at installation or for maintenance. The only hardware configuration
of 100Mbps Ethernet, and shares a 100Mbps collision domain.
switch to the 100Mbps domain. Similarly, the 100Mbps traffic on ports #3 to 8 obeys the rules
10Mbps traffic domain, and can “communicate with” 100Mbps users and the switched ports
configurations, (4 repeaters, 2Km fiber distance half-duplex etc.). The 10Mbps users share a
the connected device is 10Mbps, the DS80F obeys all the rules of 10Mbps Ethernet
typically at 100Mbps full-duplex.
architecture supports a few users at 10/100Mbps, and a high speed up-link and/or server port
switched ports (one of which may be 100Mb fiber) and six dual-speed half-duplex ports. The
4.1 Dual-speed functionality, and switching
4.0 OPERATION - the function and operation of the Magnum DS80F and DS80C hubs.
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
The Magnum DS80F and DS80C units have address table capacity of 16K node
The Magnum DS80F and DS80C Personal Hubs operate in the store-and-forward
Each time a packet arrives on one of the switched ports, the decision is taken to either
Magnum DS80F and DS80C units are plug-and-play devices. There is no software
The user ports #3 to 8 are half-duplex auto-sensing for speed. (See section 2.2). When
The Magnum DS80F and DS80C Personal Hubs provides two N-way
Switching, Address Learning · through a

Switches.
allow this switched port to connect at 100Mb Full-duplex with any other auto-negotiating
(like Magnum 15E).
100Mbps fixed full duplex, only which can be useful for using Fast Ethernet media converter
standard 802.3u auto-negotiation session on RJ-45 port 1SW, but for switch 2SW, it causes
Personal Hub. While in the “FF” position, it causes full-duplex mode to be advertised for the
duplex mode.
duplex mode to be advertised for auto-negotiation on port 1SW, and for fiber it forces half-
1SW. For fiber, it forces full-duplex mode at 100Mbps. In the “H” position, it causes half-
duplex mode to be advertised for the standard 802.3u auto-negotiation session on RJ-45 ports
mounted on the front-left of the DS80F personal hub. While in the “F” position, it causes full-
4.3 Full or Half - Duplex, manual switch selection for DS80F Models
default to 10Mbps speed and half-duplex mode, per the IEEE 802.3u standard).
operation. (If a DS80F or DS80C RJ-45port is connected to a non-negotiating device, it will
blinking ON indicates the port is transmitting / receiving. The port has auto-negotiated for
agreement to operate at either 10Mbps or 100Mbps speed.
will agree to the speed being used. Depending upon the device connected, this will result in
and the device at the other end of the cable should similarly advertise / respond and both sides
negotiation takes place. The DS80F or DS80C advertises it capability for 10 or 100 Mbps speed,
and 100BASE-TX modes. Operation is according to the IEEE 802.3u standard.
4.2 Auto-negotiation and speed-sensing
frequently-used addresses. To reset the address buffer, cycle power down-and-up.
keeps up with node locations.
added or removed or moved from one segment to another, the DS80F and DS80C automatically
addresses, and is suitable for use in large networks. They are self-learning, so that as nodes are
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
While in “A” position, the switched port 2SW is set at 10/100 auto-negotiation, that
Port 2SW have a “FF - A” manual switch mounted on the front-left of the DS80C
Ports 1SW and 2SW (the switched ports) have a common “F - H” manual switch
When the ‘LINK/ACT’ LED is ON, steady ON indicates LINK with no traffic
When a RJ-45 cable connection is made, and each time when a LINK is enabled, auto-
All eight RJ-45 ports independently support auto-negotiation for speed in 10BASE-T
An address-aging algorithm causes least-used addresses to fall out in favor of new

best to use only 10Mb media converters on ports 3 to 8.
15E). If media converters are attached to ports 3 to 8, they will operate in HDX mode. It is
Full duplex fixed only which is useful for the fast ethernet media converter (e.g. Magnum
mode as set by the user.
with auto-negotiating ports, defaulting to 100Mb half-duplex) usable in either HDX or FDX
set to FDX manually, making typical 100Mb media converters (which can be troublesome
may be desired, a media converter may be used. For DS80F, the two switched ports can be
4.7 Use with Media Converters
ports will auto-negotiate to operate the connection at 100Mb/s.
need any PDV calculation for distances. Two DS80F and DS80Cs cascaded using RJ-45
operated at 100Mbps speed, because of its full duplex and switched port capability, does not
count limits, etc.) for 10Mbps domains are in effect. When the cascaded connection is
on different ports. When attaching a 10Mbps hub, the Ethernet configuration rules (hop
DS80F even supports cascaded connections of both 10Mbps and 100Mbps at the same time
as regular ports for 10Mbps or 100Mbps speed auto-sensing connections.
repeater-to-repeater connections without a special cross-over cable. Port 1SW works the same
allows its RJ-45 cable to connect for cascading to another hub or switch port. This allows
mode.
port 1SW, on the front of the Personal Hub. This port can operate either Full/Half duplex
4.6 Up-link Port
4.5 LED’s PWR: Illuminates GREEN, steady on when power applied. ERROR: Indicates the self-test at power up was not successful SPEED: Per port, ON = 100Mbps; OFF = 10Mbps (when LINK is made) LINK/ACT: Per port, steady ON for LINK with no traffic, blinking indicates port is transmitting and receiving. F/H: (For full/half switched ports 1SW and 2SW only) ON = Full-Duplex and Link, OFF = Half-Duplex and / or no Link.
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
Whereas for DS80C the switched port 2SW at “FF” position supports 100Mbps
Where an additional fiber connection (beyond the built-in fiber port as on D80F)
Cascaded connections may be operated at either 10 or 100Mbps speed. The
The up-link (or cross-over) on the #1SW( N-way auto-negotiating switched port)
Magnum DS80F and DS80Cs have one manual crossover (MDIX up-link) switch,

5.1 Before Calling for Assistance
alter the unit. Contact your supplier or if unknown, contact GarrettCom Customer Support.
or if the Magnum DS80F or DS80C hub is not operating as expected, do not attempt to repair or
contacting your supplier. However, if you are unsure of any procedure described in this section,
locate, identify and correct such problems. Please follow the suggestions listed below prior to
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
operation is easy and is described in Section 4.0, OPERATION.
and DS80C Dual-Speed Hub is a simple procedure (see Section 3.0, INSTALLATION);
high performance in all network environments. The installation of a Magnum DS80F
email (support@garrettcom.com) for assistance.
Magnum 4K-Series unit or if unknown, contact GarrettCom, Inc. by fax, phone or
are functioning properly.
below. If the problem is corrected, the Magnum 4K-Series and its associated cables
good device. Verify whether or not the problem is corrected. If not, go to Step 5
Series product, it is recommended that the problem device is replaced with a known
outlet. Use the PWR LEDs to verify each unit is receiving power.
unit. Be certain that each AC power cord is plugged into a functioning electrical
attributed to wiring and connector problems.)
impaired during installation. (About 90% of network downtime can be
connected and the cables/wires have not been crimped or in some way
that the various components of the network are interoperable.
Installation Section of the applicable chapter of this manual. Also check to make sure
Should problems develop during installation or operation, this section should help to
All Magnum Ethernet products are designed to provide reliability and consistently

calling, please have the following information readily available:
9071 during business hours in California or email to support@garrettcom.com). When
(RMA) number. To obtain an RMA number, call GarrettCom Customer Service at (510) 438-
5.3 Return Material Authorization (RMA) Procedure
5.2 When Calling for Assistance
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
to the occurrence of the problem. Any changes to system administration
network media types being used.
Failure symptoms, including a full description of the problem.
Packing List Number (or Sales Order Number)
Serial Number (or Invoice Number)
Name of your company / institution
Name and phone number of your contact person.
All returns for repair must be accompanied by a Return Material Authorization
procedures should all be noted in this record.
including personal computers, workstations, terminals and printers; plus, the various
Include the date(s) that you purchased the products from your supplier.
d. Any particular application that, when used, appears to create the problem;
c. The components involved in the problem;
b. Situations when the problem occurs;
a. The nature and duration of the problem;
Please be prepared to provide the following information.
Date of installation · Product name · Your shipping address

APPENDIX A: WARRANTY INFORMATION GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom. During this warranty period, GarrettCom will repair or, at its option, replace components in the products that prove to be defective at no charge other than shipping and handling, provided that the product is returned pre-paid to GarrettCom. This warranty will not be effective if, in the opinion of GarrettCom, the product has been damaged by misuse, misapplication, or as a result of service or modification other than by GarrettCom. GarrettCom reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty. Please complete the warranty card as this acts as a product registration, and mail it to GarrettCom within two weeks of your purchase.
5.4 Shipping and Packaging Information
GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details). However, if the problem or condition causing the return cannot be duplicated by GarrettCom, the unit will be returned as: No Problem Found. GarrettCom reserves the right to charge for the testing of non-defective units under warranty. Testing and repair of product that is not under warranty will result in a customer (user) charge.
Magnum DS80F & DS80C Dual-speed Stackable Hubs Installation and User Guide (12/01)
Should you need to ship the unit back to GarrettCom, please follow these instructions: 1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection. ( You may retain all connectors and this Installation Guide.) CAUTION: Do not pack the unit in Styrofoam "popcorn" type packing material. This material may cause electro-static shock damage to the unit.