10 / 100Mb Dual-Speed Stackable Hubs

Installation and User Guide

GarrettCom DS8016 — 10 / 100Mb Dual-Speed Stackable Hubs diagram (page 1)
Fig. 2 · 10 / 100Mb Dual-Speed Stackable Hubs

Magnum DS8016

Page 2 of the GarrettCom DS8016 user manual
Page 2 · click to enlarge
Page 2
Page 2 of the GarrettCom DS8016 user manual
Page 3 of the GarrettCom DS8016 user manual — Magnum ™ DS8016
Page 3 · click to enlarge
Page 3

contains no user serviceable parts. Attempted service by unauthorized personnel

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a

shall render all warranties null and void. If problems are experienced with

Magnum DS8016 10/100 Dual Speed Stackable Hubs, consult Section 6,

of this publication may be reproduced without prior written permission from

Installation and User Guide

10/100Mb Dual-Speed Stackable Hubs

Copyright © 2006 GarrettCom, Inc. All rights reserved. No part

Magnum ™ DS8016

Part #84-00120, Rev. C (04/01)

UL is a registered trademark of Underwriters Laboratories

NEBS is a trademark of Telcordia Technologies

Troubleshooting, of this User Guide.

Ethernet is a trademark of Xerox Corporation

registered trademark of GarrettCom, Inc.

Printed in the United States of America.

GarrettCom, Inc.

Trademarks

Page 4 of the GarrettCom DS8016 user manual — Phone (510) 438-9071
Page 4 · click to enlarge
Page 4

This equipment generates, uses and can radiate frequency energy and if not

installed and used properly, that is in strict accordance with the manufacturer's instructions,

may cause interference to radio communication. It has been tested and found to comply with

the limits for a Class A computing device in accordance with the specifications in Subpart J

of Part 15 of FCC rules, which are designed to provide reasonable protection against such

interference when operated in a commercial environment. Operation of this equipment in a

residential area is likely to cause interference, in which case the user at his own expense will

Please use the mailing address, phone and fax numbers and email address listed below:

be required to take whatever measures may be required to correct the interference.

Radio Frequency Interference Statement

Websitehttp://www.GarrettCom.com

email support@garrettcom.com

47823 Westinghouse Dr. Fremont, CA 94539-7437

GarrettCom, Inc.

Phone (510) 438-9071

Federal Communications Commission · Fax (510) 438-9072 · Contacting GarrettCom, Inc

Page 5 of the GarrettCom DS8016 user manual — OVERVIEW
Page 5 · click to enlarge
Page 5

GarrettCom, Inc.offers the premium-quality Magnum™ line of Ethernet LAN

connectivity products with industry-standard functionality and built-in fiber

configurability. Magnum products are designed for use in demanding Carrier Class,

2, 4 and 8 Port Models Transceivers, 10Mb and 100Mb series 10Mb Mini-Transceivers and

Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports,

4K-Series Switches, 100 & 10Mbps, copper ports with optional fiber port, with auto-negotiating full switching performance

“Outdoor” Ethernet Switch, for temperature uncontrolled locations

6 10/100 and 2 100Mb fiber ports, can be connected in strings Mixed-Media Fiber Hub, 16-port Stackable, 10/100 auto-sensing

8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series

Industrial Grade and OEM applications where reliability is a primary consideration.

10Mb series and 100Mb series, both w/ optional port modules Personal Switches, 10/100Mb

All media combinations, incl. fiber ST, SC, mm., single mode

Repeater Port Modules (RPMs), 6 types for Ethernet media

Bridge Port Modules (BPMs), 4 types, for segment isolation

Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing

mixed-speed and mixed-media types, full switching performance

Stackable Concentrators, SNMP optional, 13-Ports

Coax Models, All Types - July, 06

8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb

ETHERNET CONNECTIVITY PRODUCTS

The “X-line” of configurable Mi X ed Media products:

Mini-Concentrators, 7 Ports, Repeaters, 2-Ports

"DESIGNED AND MANUFACTURED IN THE USA"

8-port, with two switched ports (1 fiber built in) Personal Hubs, 10Mb series

The Magnum Line

OVERVIEW

Stackable Hubs, SNMP Optional

Fan-Outs, 10Mb series

Page 6 of the GarrettCom DS8016 user manual — Table of contents
Page 6 · click to enlarge
Page 6

Table of contents

1.0 SPECIFICATIONSp.91.1 Technical Specificationsp.91.2 Ordering Informationp.102.0 INTRODUCTIONp.112.1 Inspecting the Package and Productp.122.2 Product Description - Generalp.132.2.1 Magnum DS8016 Chassisp.142.2.2 10 / 100 Speed Auto-sensingp.152.2.3: Magnum DS8016-E model, 100Mbps -onlyp.162.2.4: Magnum DS8016-R “reverse” model, front LEDs and connep.162.3 Stacking Magnum DS8016sp.172.4 Bridge Module between the 10Mb and 100Mb Domainsp.182.5 Up-link, Port 1X for Cascadingp.182.6 Features and Benefitsp.192.7 Applicationsp.203.0 Magnum DS8016 Installationp.233.1 Locating Magnum DS8016 Dual-Speed Hubsp.233.1.1 Table-Top or Shelf Mountingp.233.1.2 Rack-Mountingp.243.2 Connecting Ethernet Mediap.253.2.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unship.263.2.2 Attaching to the MII port in the rearp.263.2.3 100Mbps Collision Domain Diameter, Cable Distances andp.263.2.4 Connections to NICs which support Auto-Negotiationp.293.3 Powering the Magnum DS8016p.294.0 OPERATIONp.304.1 Dual-Speed and Domain-Switched Functionalityp.304.2 Auto-negotiation and speed-sensingp.334.3 LED’sp.334.4 Up-link Port 1Xp.345.0 TROUBLESHOOTINGp.355.1 Before Calling for Assistancep.355.2 When Calling for Assistancep.365.3 Return Material Authorization (RMA) Procedurep.365.4 Shipping and Packaging Informationp.37APPENDIX A: WARRANTY INFORMATIONp.37APPENDIX B : Optional 48V DC Power Supply, Addendump.38APPENDIX C: Optional 48V Dual-Source DC Power, Addendump.40
Page 7 of the GarrettCom DS8016 user manual
Page 7 · click to enlarge
Page 7
Rev B 03/99Added Reverse model specifications and collision domain diameter, cable
Rev A 07/98This revision is the initial release of the DS8016 10/100 Dual Speed

distances and pdv calculations

Stackable Hubs user manual.

Page 8 of the GarrettCom DS8016 user manual
Page 8 · click to enlarge
Page 8
Page 8 of the GarrettCom DS8016 user manual
Page 9 of the GarrettCom DS8016 user manual — 1.1 Technical Specifications
Page 9 · click to enlarge
Page 9

100 or 10 Mb/s per port, auto-sensing for speed. DS8016 hubs support two traffic domains, one at 100Mb/s and one at 10Mb/s, have sixteen RJ- 45

Packet-Processing Between Domains (internal 10/100 switch or bridge)

Packet buffers2MB,dynamically allocated & shared on both domains

Filtering and Forwarding Rate from 100Mb ports: 148,800 pps max.

addition , a Media Independent Interface (MII) port is provided per unit

ports, and are stackable up to 3 units high operating as one repeater. In

Filtering and Forwarding Rate from 10 Mb ports: 14,880 pps max.

Auto-learning8K address table, shared for both traffic domains
AC Power connectorIEC-type, male recessed, rear of chassis
Power consumption25 watts typical, 40 watts max. P.S. rating

10BASE-T (Unshielded twisted pair) - 100 m (328 ft)

When a port is operating at 10Mb/s: Data Rate = 10 Mb/s

PDV (Path Delay Value)80BT, exceeds Class II
Auto-reconnectOccurs after one packet of error-free reception
Latency (not including packet time)100 to 10Mb : 5 µ s

Ambient Temperature: 32ºF to 122ºF (0ºC to 50ºC) Storage Temperature: -20ºC to 70ºC

Ambient Relative Humidity5% to 95% (non-condensing)
Power Input Voltage90 to 260 VAC (auto ranging)
10 to 100Mb5 µ s CPU Type : State Machine

100BASE-TX (CAT 5 UTP) - 100 m (328 ft)

PartitioningEnforced after 63 consecutive collisions

100Mb: Ethernet IEEE 802.3u , 100BASE-TX 10Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3u

Maximum Ethernet Segment (or Domain) Lengths

When a port is operating at 100Mb/s:

Processing typeStore and Forward
Power Input Frequency47-63 Hz

(except on -R “reverse” models)

Data Rate100 Mb/s

1.1 Technical Specifications

1.0 SPECIFICATIONS

Power Supply (Internal )

Operating Environment · Network Standards · Performance

Page 10 of the GarrettCom DS8016 user manual — 1.2 Ordering Information
Page 10 · click to enlarge
Page 10

(Model DS8016-B,R), Off when no bridge module is inside (-A and -E)

10MbCategory 3, 4, 5 UTP (Note: speed-sensing does not sense cable type)
BRBridge Module Indicator, On when 10/100 bridge module is installed
100/AutoSpeed LED, per port. Steady On when speed is 100Mbps , Off when
MII portstandard 40-pin female MII port connector in the rear (not on -R’s)

Stacking Cable - stacking may be up to three DS8016 hubs, or 48 RJ-45 ports. A

stacking cable with 25 pin DB-25 connectors, shielded, 9 inch (23 cm) long,

Up-Link - Use first RJ-45 port, which has two connectors (only one can be used at

a time). Plug into # 1 for use as a regular user segment port, or into # 1X for

use as a cross-over (X position) up-link port for connection to a central hub or

speed is 10Mb, flashing when auto-negotiating or not connected.

Network Cable Connectors - for the 16 RJ-45 shielded female ports per hub

On-Off manual switch for AC or DC input power, located at power input

COLCollision LEDs, one each for 100Mb and 10Mb speed domains

is included with each DS8016-A and -E Dual-Speed add-on unit. (No

Dimensions1.75 in H x 17in. Wx9 in D ( 4.4cm x 43.2cm x 22.9cm)
LK/RXActivity LED per port. Steady On when twisted-pair link is

Three years, return to factory Made in USA

Power consumption25 watts typical, 40 watts max. P.S. rating

Enclosure: High strength metal. Rack-mounting brackets included.

Suitable for wiring closet shelf, 19” rack or desktop mounting.

stacking connectors are built into the DS8016-R “reverse” model).

operational Activity, flashing when port is receiving data.

48VDC Power Supply (Optional) Power Input Voltage : 36 to 72 VDC (auto ranging)

Cooling methodFan cooled, internal @ 9cfm
Terminal Block in rear“-, GND, +”
PWRSteady On when power applied
Emissionsmeets FCC Part 15, Class A

Safety :UL Listed (UL 1950), cUL, CE

100MbCategory 5 UTP/STP
Weight4.0 lb. ( 1.8 Kg)

another cascaded hub.

Show 4 more labels / short text on this page
Agency Approvals · LED Indicators · Packaging · Warranty
Page 11 of the GarrettCom DS8016 user manual — 1.2 Ordering Information
Page 11 · click to enlarge
Page 11
Magnum DS8016-ADual-Speed 10/100 Stackable Hub with sixteen RJ-45ports, each

with all ports in one stack operating as two separate traffic domains, one domain

Magnum DS8016-ESame as Magnum DS8016-A but all ports operate at 100Mbps

10/100device for 100Mbps speed and half-duplex mode only. May be used in

Magnum DS8016-RSame as Magnum DS8016-B but with all ports on the rear side

module that bridges the two traffic domains, filtering and selectively forwarding

packets between the 100Mb and the 10Mb domains. Stacks up to two DS8016-

and all of the LEDs are on front panel. No stacking. Normally used with 48V

auto-sensing for 100Mb or 10Mb operation. Stackable up to three units high,

at 100Mb/s and one domain at 10Mb/s. Includes stacking cable, internal auto-

only(not dual speed-speed). Each port will auto-negotiate with an attached

RMB-23WSet of two mounting brackets that extend a standard 19” DS8016 hub
Magnum DS8016-BSame as Magnum DS8016-A but includes an internal switch

communicating with each other. The internal switch has 2Mb dynamic store-

A units. One DS8016-B unit stack supports all ports at 100Mb or 10Mb

ranging power-supply, cooling fan, and metal brackets for shelf or wall

Magnum DS8016 Dual-Speed Stackable Hubs

GarrettCom, Inc. reserves the right to change specifications, performance

DC dual source power supply, mounted in telco racks.

and-forward packet buffers and 8K node addresses.

for mounting in a 23” -wide telco rack, 1U high.

DS8016 stacks, same as Model DS8016-A.

characteristics and/or model offerings without notice.

1.2 Ordering Information

mounting.

Page 12 of the GarrettCom DS8016 user manual — 2.0 INTRODUCTION
Page 12 · click to enlarge
Page 12

Examine the shipping container for obvious damage prior to installing this product;

Inspect the contents of this package for any signs of damage and ensure that the items listed

1 Stacking Cable, Model DS8016-A and -E add-on (no bridge inside) units only

In the event there are items missing or damaged contact your supplier. If you need

notify the carrier of any damage which you believe occurred during shipment or delivery.

Remove the Magnum DS8016 Dual-Speed Hub from the shipping container. Be

validate the product warranty please complete and return the enclosed Product Registration

to return the unit use the original shipping container. Refer to Chapter 5, Troubleshooting,

sure to keep the shipping container should you need to ship the unit at a later date. To

1 AC Power Cord (U.S. and other 115 vac locations only)

1 Set of metal “Ears” for optional rack mounting

1 Magnum DS8016-series Dual-Speed Hub unit

2.1 Inspecting the Package and Product

Card to GarrettCom, Inc. as soon as possible.

1 Installation and User Guide

1 Product Registration Card

2.0 INTRODUCTION

for specific return procedures.

This package should contain:

below are included.

Page 13 of the GarrettCom DS8016 user manual — 2.2 Product Description - General
Page 13 · click to enlarge
Page 13

Magnum DS8016 Dual-Speed hubs have sixteen RJ-45 ports, each 10/100Mb auto-

device. There are two internal traffic domains in Magnum DS8016 hubs, one for the 100Mb

traffic and one for the 10Mb traffic. The 100Mb users share the 100Mb domain’s bandwidth

Figure 2.2 aMagnum DS8016s are functionally both a 10Mb and a 100Mb hub in one

As Magnum DS8016 Dual-Speed units are stacked, the two shared traffic domains

100Mb ports, up to the maximum of 48 ports (3 units) in one stack, can be in use at any time.

Some DS8016 models, the Magnum DS8016-B and DS8016-R, include an internal

bridge or switch module which interconnects the 10 Mb and the 100Mb traffic domains. This

added or removed or move from one speed domain to the other, the DS8016-B’s (or DS8016-

sensing *. Each port can independently identify (via IEEE 802.3u auto-sensing) and accept

Any DS8016 port can connect into either the 100 or the 10Mb traffic domain, and

can also change from one traffic domain to the other at any time without affecting the speed

automatically expand to support all of the ports in the stack. Any combination of 10Mb and

enables all users on a DS8016-B or -R hub or a DS8016 stack, whether 100Mb or 10Mb, to

packets between the 10Mb and the 100Mb domains, maintaining peak performance in each

domain unaffected by local traffic in the other domain. The internal bridge is self-learning,

either 100Mb or 10Mb Ethernet signals, adapting to match the best speed of the connected

* Note: the “special 100Mb-only” model DS8016-E is not dual-speed. See Section 2.2.3 below.

of other ports. The automatic per-port speed-sensing is continuous (it takes place at LINK

enable, see section 4.2 for details), allowing the connected devices to change speed at any

GarrettCom DS8016 — 2.2 Product Description - General diagram (page 13)
Fig. 3 · 2.2 Product Description - General

talk to each other. The internal switch of the DS8016’s filters and selectively forwards

with large address table capacity for up to 8K node addresses. As networked nodes are

1 2 3 4 5 6 7 8 9 10 11

time without impairing the operation of the other ports and connected devices.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

and the 10Mb users share the 10Mb domain’s bandwidth.

2.2 Product Description - General

R’s) internal switch automatically keeps track.

PWR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

PWR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Page 14 of the GarrettCom DS8016 user manual — 2.2.1 Magnum DS8016 Chassis
Page 14 · click to enlarge
Page 14
GarrettCom DS8016 — 2.2.1 Magnum DS8016 Chassis diagram (page 14)
Fig. 4 · 2.2.1 Magnum DS8016 Chassis

bridge module inside, and which cost less accordingly . . . can be added to the stack, up to the

Each DS8016 has its own internal power supply, and is easily added to an existing 10 or

Only one DS8016-B unit is needed to support a stack. Additional 16-port units of

function as dual-speed stackable hubs. This could be desired if an external non-auto-sensing

in the Model DS8016-B and DS8016-R, and an internal power supply unit. The front side of

the chassis has sixteen RJ-45 twisted-pair ports, one of which (Port #1X on the left-front) can

Another DS8016 model, the DS8016-A, has no switch module inside, but is dual

Figure 2.2 bThe DS8016-B is a DS8016 with a bridge module built-in for 10 and

3-unit stack maximum. In a stack, the DS8016-B unit (illustrated below as the bottom unit)

switch (such as the Magnum 300ES Two-Port Switch) is available to interconnect the two

The Magnum DS8016 chassis houses one main PC board, a bridge module daughter- board

1 2 3 4 5 6 7 8 9 10 11

the DS8016-A “add-on” and/or DS8016-E “100-only” hubs . . . units that do not have the

speed domains, or if only 100Mb devices are connected (use the DS8016-E for this? See

Figure 2.2 cStack of DS8016’s, 2@ DS8016-A’s and 1 @ DS8016-B

DS8016-A units can also be used without a DS8016-B, whereupon they will

speed and is normally used stacked with a DS8016-B for dual-speed port expansion.

100Mb network. DS8016s are suitable for wiring closet shelf, table-top or 19” rack-

2.2.3 below) and the 10Mb domain is unused, or if dual-speed operation with two

DS8016-A DS8016-B Bridge

1 2 3 4 5 6 7 8 9 10 11 12 13 14

mounting. Optional brackets for 23” telco rack-mounting are available.

unconnected and uncoordinated domains is needed for the application.

2.2.1 Magnum DS8016 Chassis

be used for cascading (UP-LINK).

1 2 3 4 5 6 7 8 9 10 11

can be in any stack position.

1 2 3 4 5 6 7 8 9 10 11 12 13 14

100Mb

Page 15 of the GarrettCom DS8016 user manual — LK/RX
Page 15 · click to enlarge
Page 15

indicates that it is capable of 100Mb speed, then operation on that port will be at 100Mb/s. If

and bridge-inside (BR) indicators for the unit. There are collision (COL) indicators for each

away from the unit to the side. Stacking cables connect in the rear, except for the DS8016-R

The AC power cord connector, a universal recessed-male IEC type, is in the left

rear of the chassis. The internal AC power supply is auto-ranging for any AC power input of

All sixteen RJ-45 twisted pair ports support auto-sensing for speed, independent of

the other ports. Speed-sensing is performed by the DS8016’s electronics in accordance with

the standards of the IEEE 802.3u auto-negotiation standard. If the connected device or node

When a port is connected and LINK is present, the speed on that port that has been

the connected device does not positively indicate that it is capable of 100Mb speed, then the

LEDs to indicate operating status are on the front side. There are power (PWR)

description of the LEDs). The unit has a cooling fan on the side which sends warm air out

blinking to indicate that it is trying to auto-negotiate. (See section 4.3 for operation of the

Partition and Magnum DS8016 Dual-Speed Hub

operation on that DS8016 port will be at 10Mbps. Of course, the hubs’ auto-negotiation

technique is only for 10 / 100 speed, and does not provide for any full-duplex operation.

sensed by the DS8016 hub will be indicated by the ‘100M/Auto’ LED for that port. The

‘100’ LED is ON when 100Mb speed is sensed, and is OFF when 10Mb speed is in use.

100M/Auto indicators for each port. (See Section 1.1 “Specifications” for a technical

115. 230 vac, 50 - 60 Hz. (An internal DC power supply is optional, see Appendix A).

When a port is not connected, the ‘100M/Auto’ LED corresponding to that port will be

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X

BR Magnum DS8016 Stackable Hub

100 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

model. (see Section 2.3 for stacking information).

LK/RX

PORT

2.2.2 10 / 100 Speed Auto-sensing

COL 10

COL 100

PWR

of the 10Mb and 100Mb domains,

operating status of each domain.

And there are link (LK/RX),

for visual indication of the

LED’s).

Page 16 of the GarrettCom DS8016 user manual — 2.2.4: Magnum DS8016-R “reverse” model, front LEDs and connections in rear
Page 16 · click to enlarge
Page 16
GarrettCom DS8016 — 2.2.3: Magnum DS8016-E model, 100Mbps -only diagram (page 16)
Fig. 5 · 2.2.3: Magnum DS8016-E model, 100Mbps -only

In addition, the MII port in the rear of other DS8016 models is not present for the DS8016-R.

100Mbps-only applications, and it can operate stand-alone or stacked with the other DS8016-

to talk to each other. The DS8016-R operates stand-alone, i.e., it is a non-stackable model.

Special orders of this model can be built with some ports fixed at 10Mb. If your

application requires a mix of fixed 100Mb and fixed 10 Mb ports, request a special quote.

The Magnum DS8016-R is like the DS8016-B except that the front panel has

the LEDs, and all the connecting ports and power feeds are in the back. This is convenient

bridge module interconnects 10 Mbps and 100Mbps domains, allowing all connected users

Magnum DS8016-R a good high-availability choice for telcos, ISPs, broadcast equipment,

fixed at 100Mbps on all ports. It is not dual-speed. It has no bridge inside. It is used for

2.2.4: Magnum DS8016-R “reverse” model, front LEDs and connections in rear

for rack-mounting where cabling is accessed from the rear of the rack while the operating

status LEDs are monitored from the front. Typically such arrangements are found in telco

The Magnum DS8016-R is dual-speed, and has a bridge module inside. The

Normally the DS8016-R is quipped with an optional internal 48VDC power

supply (See Appendix A). There is an additional option of a dual-source 48V input (See

The Model DS8016-E is like the DS8016-A except that it’s speed is internally

100 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

The DC power feed options and the high quality and versatility make the

medical, brokerage firm and financial facilities. In applications where downtime of the

operation is not acceptable, the DS8016-R provides a good Ethernet LAN solution.

2.2.3Magnum DS8016-E model, 100Mbps -only

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X

B and DS8016-A models.

rack installations.

Appendix B).

Page 17 of the GarrettCom DS8016 user manual — 2.3 Stacking Magnum DS8016s
Page 17 · click to enlarge
Page 17

Up to three Magnum DS8016s can be stacked to operate as one 10/100 dual-speed

repeater with up to 48 dual-speed ports. Normally, one Magnum DS8016-B hub per stack is

light up when power is applied to indicate that a DS8016 is a -B (bridge inside) model. (The

traffic domains in the stack. Additional stacked units are normally Model DS8016-A or -E

Figure 2.3Magnum DS8016’s stacked. Cables connect between “Out” and “In” Ports

DS8016-A or -E units (no bridge inside) from the outside. The “BR” LED on the front will

when more than one is present. (Note that two DS8016-B units may be cascaded to operate

together, however). Use DS8016-B models non-stacked, or with only 1 Model DS8016-B in

When connecting DS8016s in a stack, use the stacking cable to connect the “Out”

stacking port from one DS8016 unit to the “In” stacking port of the other. Push in the cable

needed to provide a switched interconnection between the two separate 100Mb and 10Mb

“add-on” units, which cost less. The stacks can also include Magnum 8000X Fiber Hubs.

cannot be stacked together, as their internal bridges would not be able to function properly

When stacking DS8016’s, please make sure to use only the shielded 9-inch long

connectors until they seat in firmly. Also, leave space along the left-side (from the front)

stacking cable provided with each DS8016-A or -E unit. The cable length is designed to

unshielded cables are not permitted as they will not operate properly at 100Mb speeds.

“BR” LED will be off if the unit is a Model DS8016-A or -E). The DS8016-B models

area for the exhaust of the internal cooling fan in each DS8016 unit. SeeFig.2.3) above.

GarrettCom DS8016 — 2.3 Stacking Magnum DS8016s diagram (page 17)
Fig. 6 · 2.3 Stacking Magnum DS8016s

The DS8016-B models with the bridge module inside look the same as the

provide proper operation of up to three DS8016 units in a stack, and longer cables or

a DS8016 stack. See Section 2.7, Example 3.

2.3 Stacking Magnum DS8016s

Page 18 of the GarrettCom DS8016 user manual — 2.4 Bridge Module between the 10Mb and 100Mb Domains
Page 18 · click to enlarge
Page 18

The DS8016-B’s and DS8016-R’s bridge module is implemented as a daughter board.

100Mb or 10Mb, to talk to each other, and it keeps local traffic on one domain from consuming

The bridge operates in the store-and-forward mode, which filters out bad packets and

10Mb and of 100Mb packets is maintained correctly even when users move their connection, or

DS8016-R’s contain a factory-installed bridge module to interconnect the two traffic domains,

suitable for use in large networks. Addresses are self-learning so that filtering / forwarding of

The unit has an Up-link Port 1X, located on the left-front side of the hub. It enables

filtering and selectively forwarding packets to allow only necessary packets to cross between

maintains optimum performance in both domains. Packet forwarding delay is only 5µs (plus

DS8016s to maintain high network performance. The bridge has 8K node address capacity,

installed internally. Power up any DS8016 unit, and if the BR LED is ON, it is a Magnum

use only one crossover port for the cascaded hubs connection. When the Up-link port is used

10 BUS 100

the domains. This enables all of the users and nodes connected into either domain, whether

the first port’s RJ-45 cable to either connect to a user station ( port 1) or to be cascaded to

connected device. Use port 1X on one DS8016 and port 1 (or any port) on the second, i.e.,

packet time), much less than traditional store-and-forward bridge products, enabling the

another hub (port 1X) with cross-over. (See Section 4.4 for more details about Up-link).

DS8016 units have an LED on the front labeled BR that will be ON when the module is

Like all DS8016 ports, Port # 1X is a dual-speed port which will sense the speed of the

allowed per repeater stack. Thus, if the DS8016s in a stack have more than

2.4 Bridge Module between the 10Mb and 100Mb Domains

one BR (bridge) LED ON, it is an illegal configuration.

2.5 Up-link, Port 1X for Cascading

Figure 2.4Internal view of DS8016-B

any of the bandwidth of the other domain.

with bridge module installed

change speed, or power down.

DS8016-B or DS8016-R unit.

Bridge · Module · Magnum DS8016-B’s and

Page 19 of the GarrettCom DS8016 user manual — 2.6 Features and Benefits
Page 19 · click to enlarge
Page 19

All ports support 10/100 auto-negotiation for speed, operating separately on each port.

10Mb and one at 100Mb . . . in one physical box supporting two traffic domains. Each

each domain, unaffected by local traffic on the other domain. One DS8016-B per stack

dual speed. As additional units are added in a stack, 10 and 100Mb traffic domains are

The Magnum DS8016-B operates as a hardware switch, only forwarding those packets

100Mb or 10Mb speed at any time (LINK off, then on again), adapting automatically

self-learning, enabling users to change port connections or 10 / 100 domains without

occurs at LINK-enable independently on each port. Individual ports can change to

to any changes in the connected device’s speed. Speed-sensing complies with IEEE

communicate to each other. High performance switching provides full bandwidth in

Magnum DS8016s can be stacked up to three units high for 48 ports, each 10 / 100

Magnum DS8016 Dual-Speed 10 / 100 hubs combine two logical hubs . . . one at

Any mix of 10Mb and 100Mb users can be connected to the ports. Speed-sensing

Model DS8016-BAND DS8016-R has an internal switch for filtering / forwarding

from each domain that are needed on the other domain. Internal address tables are

to cascade two DS8016 hubs or stacks together, the auto-sensing feature will cause the

„ Supports 10 or 100Mb network connections on each of sixteen RJ-45 ports

„ An internal switch connects the 10 and 100Mb domains on Model DS8016-B

expanded automatically to support the new ports at either 10 or 100Mb speed.

affecting operations. The switch in the DS8016-B will not affect any standard

traffic between the 10 and 100Mb domains, allowing all connected devices to

„ Installation is “Plug and Play”, Operation is Transparent to Software

port can operate at either 10 or 100Mb, independently of the other ports.

software applications or SNMP network management platforms.

802.3u, providing interoperability with other products.

„ Auto-sensing for speed, 10 or 100Mb on each port

connecting link to operate at 100Mb speed.

supports switching for all ports.

„ Stackable for flexible expansion

2.6 Features and Benefits

Page 20 of the GarrettCom DS8016 user manual — 2.7 Applications
Page 20 · click to enlarge
Page 20

Example 1 : A Magnum DS8016-B serves a small office with mixed speed requirements.

Some users operate at 100Mb, and some users and utility devices (such as print servers) run

GarrettCom DS8016 — 2.7 Applications diagram (page 20)
Fig. 7 · 2.7 Applications
Figure 2.7.1DS8016-B connects combinations of 10Mb and 100Mb network devices

into any port of the DS8016-B. This allows simple plug-and-play addition of 100Mb ports to

higher speed. The dual-speed ports on the DS8016-B can be used for adding 100Mb users or

at 10Mb. All share the same hub, and talk to each other via the bridge module inside. Any

node can change speed at any time without affecting network operation or impacting other

Example 2Where there are existing 10Mb hubs and users, they can easily be cascaded

an existing 10Mb network without having to change it. Nodes that are capable of 100Mb

speed can be moved to any DS8016 dual-speed port, and will automatically operate at the

for accommodating existing high performance users. The 100Mb traffic does not use the

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

bandwidth of the 10Mb domain, so overall performance of the network is improved.

1 2 3 4 5 6 7 8 9 10 11 12

13 14 15 16 X

GARRETT

Magnum DS8016 Stackable Hub

UPLINK

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

LK/RX

PORT

PWR BR

COL 10

COL 100

6 7 8 9 10 11 12 13 14 15 16

Figure 2.7.2DS8016-B adds a

new 100Mb domain to existing

2.7 Applications

users.

Show 10 more labels / short text on this page
Print Server · 100 100 · 100 100 · 10 Mb Hub · 100 100 · 10 10 10 · 100 100 100 · Router · 100 Server · 10Mb network
Page 21 of the GarrettCom DS8016 user manual — GA RRETT
Page 21 · click to enlarge
Page 21

on” units. The additional stacked ports are all auto-sensing dual-speed domain-switched, and

When one DS8016-B unit with a bridge inside is present in a stack, its bridge will support all

types, cable distances, etc.) and can be treated as one 10Mb repeater accordingly. Separately,

the 100Mb traffic domain obeys all of the rules of 100Mb Fast Ethernet shared networks (hop

bridge-isolation of one domain from the other, filtering and selectively forwarding 10Mb and

For additional expansion, DS8016s can be expanded by stacking DS8016-A “add-

repeater is both a 10Mb hub and a 100Mb hub at the same time. This means that the 10Mb

counts, PDVs, cable types, cable distances, etc.) and can be treated as one 100Mb repeater.

traffic domain or segment has its own local traffic with the Magnum DS8016-B performing

The stacking cables connect the DS8016 units and carry the signals for both the

domain while all 100Mb ports are similarly together on a separate 100Mb traffic domain.

traffic domain obeys all of the rules of 10Mb shared Ethernet networks (hop counts, cable

an Ethernet or Fast Ethernet installation, the Magnum DS8016 Hubs are ideally suited for

connecting servers and stations that have (or may have in the future) mixed speeds. Each

100Mb packets between the two domains. This keeps the traffic between the domains to a

100Mb and the 10Mb domains. In a stack, all 10Mb ports are together in a 10Mb traffic

A Magnum DS8016 stack operates as one dual-speed repeater. A dual-speed

of the ports in the stack and enable network traffic to move between the two stacked

Both traffic domains function within the same physical DS8016 hub or stack of hubs.

GarrettCom DS8016 — 2.7 Applications diagram (page 21)
Fig. 8 · 2.7 Applications

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X

1 2 3 4 5 6 7 8 9 10 11 12

minimum and provides peak performance on both domains.

can be used at either 10Mb or 100Mb on a per-port basis.

GA RRETT

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Figure 2.7.3 :

Example 3 :

domains.

Show 7 more labels / short text on this page
10 Mb Hub · Stack of Magnum · DS8016’s operate · When expanding · as one 10/100 · dual-speed · repeater
Page 22 of the GarrettCom DS8016 user manual — 2.7 Applications
Page 22 · click to enlarge
Page 22

A Magnum DS8016-R serves a good solution for the user, who expect a

an adding advantage to run the neat network setup and help the user to trace out the defective

which provide them the ability to join their existing 10Mbps network with fast ethernet. The

between 10Mbps and 100Mbps . The front panel LED display and rear port connection gives

port easily. Magnum DS8016-R has an another adding feature to run at Dual-source 48VDC,

Specially a place where existing network is supporting10Mbps user and want to expand the

GarrettCom DS8016 — 2.7 Applications diagram (page 22)
Fig. 9 · 2.7 Applications

Magnum DS8016-R connects 10Mbps and 100Mbps domain with front LEDs display

In a Telecommunication co. the user expects a very reliable and high availability system,

network with 100Mbps fast ethernet. Magnum DS8016-R equipped with bridge module

Magnum DS8016-R based on Dual-Speed with bridging facility communicate smoothly

high-availability, neat networking connection with clear visible display of LEDs port.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

provide a very effective and reliable solution for these users.

that gives a high availability and secure network.

1 2 3 4 5 6 7 8 9 10 11 12

Example 4:

Page 23 of the GarrettCom DS8016 user manual — 3.0 Magnum DS8016 Installation
Page 23 · click to enlarge
Page 23

5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised

7.) This equipment is for installation only in a Restricted Access Location (dedicated equipment room service closet and the like) in

layout of the network. Typically the hub is placed where combinations of 10Mb and 100Mb

Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum

1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment must

2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate air flow must be maintained for proper and safe

The location of a Magnum DS8016 Dual-Speed Hub is dependent on the physical

network devices need to be connected to communicate with each other. The 19” rack width

size of the unit allows it to be conveniently placed in a wiring closet, an office or a lab area,

DS8016 site. The rugged metal case of the Magnum DS8016 will normally protect it from

Before installing the equipment, it is necessary to take the

6.) If the intra-building wiring (cabling) is involved with this product(NEBS), then it is recommended to have shielded cable and

Installation: This chapter provides instructions for installing the Magnum DS8016 hubs.

The Magnum DS8016 Dual-Speed Hub can be easily mounted on a table-top or

3.) If the equipment is mounted in an enclosed or multiple rack system placement of the equipment must not overload or load

4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent

and it can also be either shelf- or rack-mounted. (See instructions in 3.1.2 below). Rack-

visually monitor the status LEDs. Keep an open area around the unit so that cooling can

accidental damage in a lab or workplace setting. Maintain an open view of the front to

any suitable horizontal surface, and has four rubber feet to provide stability without

overloading of the building/s electrical circuits.

accordance with the National Electrical code.

occur from the small fan on the left side while the unit is in operation.

3.1 Locating Magnum DS8016 Dual-Speed Hubs

the shield is grounded at both ends.

mounting brackets are included with each unit.

3.0 Magnum DS8016 Installation

3.1.1 Table-Top or Shelf Mounting

be less than or equal to 500C.

unevenly the rack system.

following precautions:

scratching finished surfaces.

earthing path.

operation.

Page 24 of the GarrettCom DS8016 user manual — 3.1.2 Rack-Mounting
Page 24 · click to enlarge
Page 24
GarrettCom DS8016 — 3.1.2 Rack-Mounting diagram (page 24)
Fig. 10 · 3.1.2 Rack-Mounting

to read. Rack-mount installation requires special rack-mounted brackets and screws (included

Magnum 8000 units. The 23” brackets are more popular in the Telco industry where they are

properly installed, the front-mounted LED status indicators should be in plain view and easy

a standard for Central Office Rack-mounting purposes. The 23” brackets are mainly used for

A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly,

BR 4 3 2 1 8 7 6 5 12 11 10 9 16 15 14 13 1

The 23” brackets and ETSI brackets are also available (optional) for Rack-mounting of

procedure. The units are 1U (1.75”) high, including the rubber feet underneath. When

Fig 3.1 Multiple Magnum 8000 units rack-mounted in a 23” Rack-mount frame

Installation of a Magnum DS8016 Stackable Hub in a 19” rack is a simple

GarrettCom DS8016 — 3.1.2 Rack-Mounting diagram (page 24)
Fig. 11 · 3.1.2 Rack-Mounting

The following instructions need to be follow up before installations-

4 3 2 1 8 7 6 5 12 11 10 9 16 15 14 13 PORT LK/R X

hub, which is then fastened into a

with each DS8016). The brackets

3.1.2 Rack-Mounting

attach to the front sides of the

operation from both sides.

Figure 3.1.2Magnum

mounting frames, and are

with the necessary screws

for attaching the brackets

23” brackets and the ETSI brackets come as a

brackets but use metric

pair in a package along

Brackets attached.

Magnum Hub unit.

standard 19”rack.

similar to the 19”

to the sides of the

dimensions.

Show 8 more labels / short text on this page
DS8016 with Rack-Mount · frequently accessed in · Standard) brackets are · The optional · (European Telephone · The ETSI · larger equipment · assemblies in rack
Page 25 of the GarrettCom DS8016 user manual — 3.2 Connecting Ethernet Media
Page 25 · click to enlarge
Page 25

room ambient. Therefore, consideration should be given to installing the equipment

equipment to the supply circuit and the effect that overloading of the circuits might

when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT

speed network, since dual-speed ports are auto-sensing for either 10 and 100Mb/s.

B) Reduced Air Flow - Installation of the equipment in a rack should be such that

maintained. Particular attention should be given to supply connections other than

3 may be used. In either case, the maximum distance for unshielded twisted pair cabling is

and 100Mb) be used whenever possible in order to provide flexibility in a mixed-

the operating ambient temperature of the rack environment may be greater than

C) Mechanical Loading - Mounting of the equipment in the rack should be such

D) Circuit Overloading - Consideration should be given to the connection of the

have on overcurrent protection and supply wiring. Appropriate consideration of

following two media types100BASE-TX and 10BASE-T. CAT 5 cables should be used

in an environment compatible with the maximum ambient temperature (Tma)

that a hazardous condition is not achieved due to uneven mechanical loading.

E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be

equipment nameplate ratings should be used when addressing this concern.

The Magnum DS8016 Dual-Speed Stackable Hubs can be connected to the

Twisted Pair (CAT 3, 4, 5) 10BASE-T RJ-45

the amount of air flow required for safe operation of the equipment is not

Twisted Pair (CAT 5) 100BASE-TX RJ-45

Media IEEE Standard Connector

direct connections to the branch circuit (e.g. use of power strips)."

3.2 Connecting Ethernet Media

specified by the manufacturer.

compromised.

100 meters (328 ft).

Page 26 of the GarrettCom DS8016 user manual — 3.2.3 100Mbps Collision Domain Diameter, Cable Distances and PDV Calculations
Page 26 · click to enlarge
Page 26
1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded,

The following procedure describes how to connect a 10BASE-T or 100BASE-TX

4. For Port #1, if the LINK LED is not illuminated, change to port 1X. If this does not help, ensure that the cable is connected properly and that the device on the other end

MII Transceivers may be attached here. Since there are no industry standards for these,

cluster of network devices which are connected by means of a repeater or repeaters such that

no bridging devices are present between any two devices in the cluster. In order to install an

depends on the physical signaling system employed. Table 3.2.3b shows each Fast Ethernet

twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and

actual network topology . . must be less than 512 BT (Bit Times). Bit Times are related to

Fiber Optic 1.000 Shielded TP cable 1.112 Category 5 Cable 1.112 Category 3, 4 Cable 1.140 *Worst case delays taken from IEEE Std 802.3u-1995, actual delays may be less for a particular cable. Contact your cable supplier for exact cable specifications.

3.2.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or

2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established

interoperability of user-selected MII transceivers that may be attached to a DS8016’s MII

between any two devices in a single collision domain. A collision domain is defined as a

port cannot be assured. Use of the MII port is not normally recommended accordingly.

IEEE 802.3u compliant Fast Ethernet network, the collision domain . . regardless of the

Each Fast Ethernet device component also has an associated BT delay which

3.2.3 100Mbps Collision Domain Diameter, Cable Distances and PDV Calculations

The 100Mbps Collision Domain Diameter is the length of the longest path

Table 3.2.3aWorst case round-trip delay for Fast Ethernet media*

Media Type Round-trip delay in

Bit Time per Meter (BT/m)

either unshielded or shielded cables and wiring may be used.

3.2.2 Attaching to the MII port in the rear

is powered and is not defective.

media type as shown in Table 3.2.3a.

shielded twisted pair cables.

Shielded)

Page 27 of the GarrettCom DS8016 user manual — PDV = (sum of cabling delays) + (sum of repeater delays) +
Page 27 · click to enlarge
Page 27

A typical example of a PDV calculation is shown below, and is illustrated in Figure

Magnum DS8016 Hubs (each having a PDV of 80 BT) for use with standard 100m Category

PDV is the Path Delay Value of the worst case path. For the network to adhere to

and may be a value between 0 and 5. This margin can be used to accommodate unexpected

delays such as extra long patch cable. A safety margin of about 2 to 4 BT is recommended.

Table 3.2.3bWorst case round-trip delay for Fast Ethernet device components*

domain diameter specification, the following formula should be applied to the worst case

IEEE standard, this value must be less than 512 BT. The safety margin is specified in BT

device component and the associated BT delay. A “DTE” is an end node, such as a user

station. Note that there is only one DTE pair associated with any device-to-device path.

To determine whether a prospective network topology adheres to the collision

path through the network. The worst case path is the path between the two Fast Ethernet

5 user cable segments (i.e. from computer to hub) and needs to know how long the inter-

repeater Category 5 cable segment, used to cascade the hubs, can be. The variable “X”

⇒ 25 m maximum total length for Category 5 inter-repeater segment,

3.2.3a. Here, an integrator wishes to cascade the 100Mbps collision domains of two

Component Round-trip delay in Bit Times (BT)

**Note, the delay is only 80 Bit Times for the DS8016, front-port-to-front-port.

PDV = (sum of cabling delays) + (sum of repeater delays) +

PDV = X + ((111 + 111) + (80 + 80) + (100) + 2 ) BT < 512 BT

Twisted Pair cable length, TL < (28 BT) / (1.112 m/BT)

2 TX DTEs 100 2 FX DTEs 100 1 FX and 1 TX DTE 100 1 T4 and 1 TX or FX DTE 127 Class I Repeater 140 Class II Repeater with any

(DTE pair delay) + (safety margin)

*Worst case delays taken from IEEE Std 802.3u -1995.

devices (DTEs) which have the longest round-trip time.

represents the unknown maximum cascade cable delay.

512 > (X + 486) BT X < (512 - 486 ) BT, X < 28 BT

combination of TX and FX ports

TL < 25 meters

92 **

Page 28 of the GarrettCom DS8016 user manual — PWR BR
Page 28 · click to enlarge
Page 28
GarrettCom DS8016 — 3.2.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshi diagram (page 28)
Fig. 12 · 3.2.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5…

The resulting value tells us that a Category 5 cable with a length of up to 25 meters

It is also possible to cascade a group of up to nine Magnum DS8016 s (serving up

segments. The following is an example of how to calculate the maximum allowable cascade

the bit time delay for each Magnum DS8016 front-to-front ports, 100 is the BT delay for the

cable segment length. An illustration of this example is shown in Figure 3.2.3b, where the

hub-to-user cable lengths are up to 75 meters for Cat 5 twisted pair. The variable “X”, the

In the above example, 75 is the BT delay for 70m of Category 5 cable (1.112 BT/m), 80 is

may be used to cascade the Magnum DS8016 s. Note that this inter-repeater cable length

100 m Cat. 5 cables to user devices

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X

may be increased by shortening the lengths of the 100m hub-to-user cable segments.

to 56 users with full-length 100m cables to each) by using short inter-repeater cable

TX DTE pair in the user stations, and 2 BT is the safety margin applied.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X

re 3.2.3aTwo cascaded Magnum DS8016 hubs

⇒ 2 meters (6 ft.) length max. for each of the cascade segments,

PDV = X + ((100) + (80 + 80 + 80 )+ (83 + 83) + 2 ) BT < 512 BT

PORT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

512 > (X + 508) BT, X < 4 BT Twisted pair user cable length, TL < (4 BT) / (1.112 m/BT)

PORT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Black Box Rackmount Dual Speed Hub

TL < 3.6 meters for two hub-to-hub cascading cables

LK/RX

100 COL 10

Cat. 5 cable for

PWR BR

COL 100

Cat. 5 cable for

100 m Cat. 5 cables to user devices

maximum hub-to-hub cable delay, is calculated as follows:

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X

100 m to us Cat. 5 cables

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 LK/RX

13 14 15 16 LK/RX

PORT 1 2 3 4 5 6 7 8 9 10 11 12

Black Box Rackmount Dual Speed Hub

BT/m* 100m), 80 is the BT delay

for each Magnum DS8016 , 100 is

the BT delay for the TX DTE pair,

and a safety margin of 2 was used.

100m of Category 5 cable (1.112

PWR BR

100 COL 10

COL 100

where 111 is the BT delay for

Magnum DS8016 hubs is a

Figure 3.2.3bMultiple
Show 7 more labels / short text on this page
cascading · er devices · Figu · capability beyond what · cascading of multiple · cascaded Magnum · DS8016 hubs
Page 29 of the GarrettCom DS8016 user manual — 3.3 Powering the Magnum DS8016
Page 29 · click to enlarge
Page 29

industry standards normally permit, and is different from what competitive 100Mbps Class II

Table 3.2.3cMaximum segment lengths for common network configurations

The Magnum DS8016 Dual-Speed Hub will function properly with NICs (Network

hub products normally allow. This additional cascading level and cable length is due to the

performed using measured PDV data supplied by the equipment manufacturer in important

Instructions for connecting the Magnum DS8016 Dual-Speed Hubs to the various

Interface Cards) which support Auto-Negotiation. The Magnum DS8016 will establish link

Magnum DS8016 Dual-Speed Hubs incorporate an internal universal power supply,

Table 3.2.3c shows maximum cable lengths for common network configurations

necessary to reload the NIC drivers on the user device if the NIC has been communicating

with a protocol other than 100BASE-TX (such as 10BASE-T). When 100Mb operation is

and have a recessed male IEC connector for the AC power cord in the rear. A six-foot 115

relatively shorter bit time (80 BT actually measured, for front-port-to-port) delay of the

installation flexibility and network growth potential is accordingly better with Magnum

agreed and in use, the 100Mb LINK/ACT LED is illuminated, steady ON if no traffic or

Magnum DS8016 vs. the industry standard delay of 92 BT for Class II repeaters. The

using industry standard repeater PDV numbers. Calculations such as above should be

with any NIC which can send and receive the Fast Link Pulse (FLP) coding for the

100BASE-TX signaling system. When connecting a NIC to the DS8016, it may be

1 1 100.0 n.a. All ports TX

2 2 100.0 5.0 All ports TX

2 2 92.0 20.0 All ports TX

3+ 3 60.0 1.0 All ports TX

3.2.4 Connections to NICs which support Auto-Negotiation

DS8016 s than with hubs that merely meet the standard.

Max. Inter-

Fast Ethernet media are given in the following sections.

3.3 Powering the Magnum DS8016

Hop Count Max. User

blinking when there is traffic.

installations.

Show 6 more labels / short text on this page
Repeater (Cascade) · Length (m) · Lengths (m) · Segment · of Hubs Repeater · Number
Page 30 of the GarrettCom DS8016 user manual — 4.0 OPERATION
Page 30 · click to enlarge
Page 30

originated, then it is filtered and not forwarded to the other domain. If the destination address

is not found to be a match in the address table for the originating domain, then it is forwarded

environments where the AC voltage is from 90 to 260 volts with an input frequency between

47 and 63 Hz, and consumes a maximum of 27 watts. In order to power the unit up or down,

maximize bandwidth utilization and performance. Magnum DS8016s are hardware plug-and-

Each time a packet is received on one domain of the bridge module, the decision is

packets, the filter and forward decisions are made based on the destination address contained

This chapter describes the function and operation of the Magnum DS8016 hubs.

play devices. There is no software set-up to be done at installation or for maintenance. The

taken to either to filter or forward the packet. Errored packets are always filtered. For good

Alternatively, the domain-switched DS8016-B provides switched (bridged) connectivity

network domains for unified operation, and filters/ forwards packets in both directions to

previously know about, it “learns” the new address and puts it in the correct port address

VAC 60Hz power cord is supplied with each unit shipped within the United States and

The Magnum DS8016-A handles the two different traffic domains separately

(unless it is stacked with a DS8016-B), and the DS8016-E has only the 100Mb domain.

between the Ethernet (10Mb/s) and Fast Ethernet (100Mb/s) domains. It joins the two

in each packet. If the destination address is on the same domain from which the packet

simply change the setting of the rear-mounted manual “On–Off” switch when there is

to the other domain. If it is a new node address coming in which the switch did not

Each Magnum DS8016’s auto-ranging power supply supports installation

4.1 Dual-Speed and Domain-Switched Functionality

functions of the DS8016s are described in this manual.

table. See “Address Learning” for more details.

4.0 OPERATION

incoming power.

Canada.

Page 31 of the GarrettCom DS8016 user manual — 4.0 OPERATION
Page 31 · click to enlarge
Page 31

total address table capacity of 8K addresses. With a large address table, a Magnum DS8016

update the network status and to purge any inactive stations from the tables of both domains.

address packet comes into a port for the first time, then the new source address is “learned”

Fig 4.1 Filtering vs Forwarding in Domain Switched Hubs with an internal

The Magnum DS8016-B bridge module is a state machine design which has a

forward action the Magnum DS8016-B will take in each packet-processing situation, and

at the same time that the packet is forwarded. After learning, subsequent packets from the

same node address are routinely processed. The address tables are flushed periodically to

when a new node address will be added to the internal Address Table. When a new node-

Packet Source Destination Address Table Filter/Forward

can serve the needs of a medium-sized to large network. Table 4.1 shows what filter /

GarrettCom DS8016 — 4.0 OPERATION diagram (page 31)
Fig. 13

in the 10Mb domain address table. 100Mbps Domain : 100Mbps packets are

10 Mb Not in table Not in table Add source to table Forward

10 Mb In table Not in table None Forward

100 Mb Not in table Not in table Add source to table Forward

100 Mb In table Not in table None Forward

Table 4.1DS8016-B Domain-Switched Hub Functionality

Source Address Address Maintenance Action

10 Mb Not in table In table Add source to table Filter

10 Mb In table In table None Filter

100 Mb Not in table In table Add source to table Filter

100 Mb In table In table None Filter

1. Filter / Forward logic for both 10Mb and 100Mb domains
2. Address Learning (Address Table Maintenance)
3. Throughput Increase
10Mb Domain10Mbps packets forwarded when the destination addresse

Bridge or Switch

Page 32 of the GarrettCom DS8016 user manual — 4.0 OPERATION
Page 32 · click to enlarge
Page 32

The Magnum DS8016-A Dual-Speed Hubs, the DS8016-E 100Mb-only Hubs and

By selectively forwarding packets from each domain to the other domain based

packets from traveling to the other domain and using up bandwidth needlessly there. This

results in more available network bandwidth on both sides and a throughput increase on for

on its switching (bridging) logic, the domain-switched Magnum DS8016-B increases the

available bandwidth for the users on both sides of the network. As shown in Figure 4.1, it

transparent to system and application software, including network management software.

keeps the local traffic on each side contained, preventing unnecessary packets and bad

the DS8016-B Dual-Speed Domain-Switched Hubs need no software set-up and are

4. Software Transparency

all users on both domains.

Page 33 of the GarrettCom DS8016 user manual — 4.2 Auto-negotiation and speed-sensing
Page 33 · click to enlarge
Page 33

connection is made, the other device should respond and both sides should agree to the speed

DS8016 port is connected to a non-negotiating device, it will default to 10Mb speed. Since

  • NOTE – some NIC cards only auto-negotiate when the computer system that they are

10BASE-T and 100BASE-TX modes. When the ‘100’ LED is flashing, it means that the

being signaled. The device connected, depending on what it is, will either signal that it is

When the ‘100’ LED is steady ON, the port has auto-negotiated for 100Mb

Magnum DS8016s are hubs, they always operate in the shared or half-duplex mode on all

the devices at both ends of the cable are capable of operation at either 10Mb or

All sixteen RJ-45 ports independently support auto-negotiation for shared

-- when the second of the two connected devices is powered up*, i.e., when

operation and is processing packets at 100Mb/s, When it is OFF, it is at 10Mb/s. If a

in is powered up. These are exceptions to the “negotiate at LINK – enabled” rule

corresponding port is sending out auto-negotiation pulses on that port. When a LINK

-- when LINK is re-established on a port after being lost temporarily.

capable of 10Mb or 100Mb speeds. Silence means the port defaults to 10Mb.

100Mb speed, and can send/receive auto-negotiation pulses, and . . .

Auto-negotiation per-port for dual-speed hubs occurs when:

4.2 Auto-negotiation and speed-sensing

above, but may be occasionally encountered.

LINK is established for a port, or

ports.

General information -

Page 34 of the GarrettCom DS8016 user manual — (DS8016A)
Page 34 · click to enlarge
Page 34

installed (Model DS8016-B), Off when no bridge module is inside

100/AutoSpeed LED per port. Steady On when speed is 100Mbps , Off when

PWR : Illuminates GREEN to indicate AC power is applied to the unit.

when port #1 is not connected. The Up-link port allows repeater-to-repeater connections

without a special cross-over cable. It works the same for 10Mb or 100Mb connections.

Use port “1” (or ports 2 thru 16) for straight-through twisted pair cabling from

connections from the first DS8016 port to a repeater or hub or switch. Verify proper port

connection by noting the port’s LINK/RX status, which is illuminated when a proper link

Magnum DS8016s each have one Up-link port, port # 1X, which can be used

Only one of these ports, either # 1 or # 1X may be used at one time simultaneously.

BRBridge Module Indicator, On when 10/100 bridge module is

the DS8016 port to a user device, or the “1X” port for cross-over or up-link segment

speed is 10Mb, flashing when auto-negotiating or when not

LK/RXActivity LED per port. Steady On when twisted-pair link is

operational. Activity, flashing when port is receiving data.

COL : Red LED Blinks intermittently when a collision occurs.

is made and blinking when there is activity.

(DS8016A)

4.4 Up-link Port 1X

4.3 LED’s

connected (no LINK)

Page 35 of the GarrettCom DS8016 user manual — 5.1 Before Calling for Assistance
Page 35 · click to enlarge
Page 35

All Magnum Ethernet products are designed to provide reliability and consistently

high performance in all network environments. The installation of Magnum DS8016 10/100

listed below prior to contacting your supplier. However, if you are unsure of the procedures

plugged into a functioning electrical outlet. Use the PWR LEDs to verify each unit

device is replaced with a known good device. Verify whether or not the problem is

Dual Speed Stackable Hubs is a straightforward procedure (see INSTALLATION, Section

Should problems develop during installation or operation, this section is intended

described in this section or if the Magnum DS8016 10/100 Dual Speed Stackable Hub is not

1. If difficulty is encountered when installing or operating the unit, refer back to the

installation Section of the applicable chapter of this manual. Also check to make

5. If the problem continues after completing Step 4 above, contact your supplier of

to help locate, identify and correct these types of problems. Please follow the suggestions

performing as expected, do not attempt to repair the unit; instead contact your supplier for

3. Make sure that an AC power cord is properly attached to each Magnum DS8016

10/100 Dual Speed Stackable Hubs unit. Be certain that each AC power cord is

10/100 Dual Speed Stackable Hub product, it is recommended that the problem

corrected. If not, go to Step 5 below. If the problem is corrected, the Magnum

contact GarrettCom, Inc.by fax, phone or email (support@garrettcom.com) for

4. If the problem is isolated to a network device other than the Magnum DS8016

the Magnum DS8016 10/100 Dual Speed Stackable Hubs unit or if unknown,

DS8016 10/100 Dual Speed Stackable Hubs and its associated cables are

2. Check the cables and connectors to ensure that they have been properly

impaired during installation. (About 90% of network downtime can be

connected and the cables/wires have not been crimped or in some way

sure that the various components of the network are interoperable.

2.6); the operation is also straightforward and is discussed in Section 4.

attributed to wiring and connector problems.)

assistance or contact GarrettCom Customer Support.

5.1 Before Calling for Assistance

5.0 TROUBLESHOOTING

functioning properly.

is receiving power.

assistance.

Page 36 of the GarrettCom DS8016 user manual — 5.2 When Calling for Assistance
Page 36 · click to enlarge
Page 36

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form. Please

2. An accurate list of GarrettCom product model(s)involved, with serial number(s).

Include the date(s) that you purchased the products from your supplier.

All returns for repair must be accompanied by a Return Material Authorization

d. Any particular application that, when used, appears to create the problem;

3. It is useful to include other network equipment models and related hardware,

including personal computers, workstations, terminals and printers; plus, the

4. A record of changes that have been made to your network configuration prior

to the occurrence of the problem. Any changes to system administration

1. A complete description of the problem, including the following points:

Failure symptoms, including a full description of the problem.

5.3 Return Material Authorization (RMA) Procedure

(RMA) number. To obtain an RMA number, please use this URL -

Please be prepared to provide the following information.

Name and phone number of your contact person.

Packing List Number (or Sales Order Number)

c. The components involved in the problem;

procedures should all be noted in this record.

a. The nature and duration of the problem;

various network media types being used.

b. Situations when the problem occurs;

have the following information readily available:

Name of your company / institution

Serial Number (or Invoice Number)

5.2 When Calling for Assistance

Your shipping address · Date of installation · Product name

Page 37 of the GarrettCom DS8016 user manual — 5.4 Shipping and Packaging Information
Page 37 · click to enlarge
Page 37

Should you need to ship the unit back to GarrettCom, please follow these instructions:

1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for

shipping protection. ( You may retain all connectors and this Installation Guide.)

products that are under warranty at no charge, and will return the warranty-repaired units

material. This material may cause electro-static shock damage to the unit.

to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for

under warranty. Testing and repair of product that is not under warranty will result in a

CAUTION : Do not pack the unit in Styrofoam "popcorn" type packing

GarrettCom, Inc. warrants its products to be free from defects in materials and

GarrettCom will carefully test and evaluate all returned products, will repair

GarrettCom reserves the right to charge for the testing of non-defective units

During this warranty period, GarrettCom will repair or, at its option, replace

shipping and handling, provided that the product is returned pre-paid to GarrettCom.

complete details). However, if the problem or condition causing the return cannot be

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

GarrettCom reserves the right to make a charge for handling and inspecting

Please complete the warranty card as this acts as a product registration, and

product has been damaged by misuse, misapplication, or as a result of service or

This warranty will not be effective if, in the opinion of GarrettCom, the

components in the products that prove to be defective at no charge other than

3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to:

workmanship for a period of three (3) years from the date of shipment by

any product returned for warranty repair which turns out not to be faulty.

mail it to GarrettCom within two weeks of your purchase.

APPENDIX A: WARRANTY INFORMATION

duplicated by GarrettCom, the unit will be returned as:

5.4 Shipping and Packaging Information

No Problem Found.

47823 Westinghouse Dr.

Attn.: Customer Service

modification other than by GarrettCom.

GarrettCom, Inc.

customer (user) charge.

GarrettCom.

Fremont, CA 94539-7437

Page 38 of the GarrettCom DS8016 user manual — B3.0 APPLICATIONS
Page 38 · click to enlarge
Page 38

The 48VDC power option is designed using diodes inside on each DC power input

line behind the two external power connection terminals, so that the power from an external

polarity connection, for example, will neither effect the hub, nor its power supply internally,

The power switch (included on premium-priced NEBS-certified units only) is used

Magnum DS8016 Dual-Speed Hubs are easily installed in a variety of applications

where 48 VDC power is used as the primary power source. The 48VDC power configuration

communication companies. In addition, many high availability equipment services, such as

broadcasters, publishers, newspaper operations, brokerage firms and other facilities often use

The solution is particularly useful in the telecommunication industry, where it is

With the exception of the power supply, all specifications and functions of

provides an Ethernet networking solution utilizing a special power supply in hubs with a

GND GND CHASSIS

common for facilities to operate on 48VDC power. Such companies include regular and

a battery backup system to maintain operations in the event of a power failure. It is also

frequently used for computer system backup, management and operations monitoring

Power Consumption: Model DS8016: 25 watt typical, 40 watts max.

SUPPLY

FUSE +

HUB POWER SWITCH

wireless telephone service providers, Internet Service Providers (ISPs) and other

Magnum DS80016-48VDC models are identical to those listed in Section 1.

for powering the hub on and off when it is placed into or taken out of service.

APPENDIX B : Optional 48V DC Power Supply, Addendum

B2.0 48V DC SOURCE OPTION, THEORY OF OPERATION

B1.0 SPECIFICATIONS - FOR DUAL-SPEED DS8016 HUBS

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

Input Voltage36 - 70 VDC (auto-ranging)

nor will it blow the fuse in the internal power supply.

A+

A-

Power Supply (Internal 48 VDC Option)

inputs. It protects the hub from incorrect

allows the hub to operate only whenever

DC power is correctly applied to the two

source can only flow into the hub. This

DC input connections. An incorrect

B3.0 APPLICATIONS

proven track record.

equipment.

Page 39 of the GarrettCom DS8016 user manual — B5.0 OPERATION
Page 39 · click to enlarge
Page 39

connection procedure is very straightforward. Simply connect the leads to the Magnum unit,

1. Minimum 14 AWG cable for connection to a Centralized DC power source. 2. Fastening torque of the lugs on the terminal block: 9 inch pound max. 3. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within

This section describes the installation of the 48 VDC power source leads to the 48

The leads are identified as negative (-), positive (+), and chassis ground (GND). The actual

On the premium-priced NEBS-compliant Magnum DS8016-48V models, an ON-

Operation of the Magnum DS8016s with the optional 48VDC power supply is

OFF switch is included, located in the rear at the power input. This can be used in

_ + GND

36-70VDC

conjunction with power connections, and as a RESET for the hub’s electronics.

VDC power terminal block on the Magnum DS8016s. (see figure below).

beginning with ground. Ensure that each lead is securely tightened.

ON

OFF

Please refer to Section 5.0 for troubleshooting

identical to that of the standard AC-powered models.

6 inches of the terminal block.

Block on Magnum DS8016-48VDC

The 48 VDC terminal block

on the rear of the unit and is equipped

with three (3) screw-down lead posts.

Figure A4.148 VDC Terminal

on the Magnum DS8016s is located

B6.0 TROUBLESHOOTING

B4.0 INSTALLATION

B4.1 UL Requirements

B5.0 OPERATION

Page 40 of the GarrettCom DS8016 user manual — A-
Page 40 · click to enlarge
Page 40

With the exception of the dual DC input power connections and the power supply, all

The hub models with the internal 48VDC Dual-Source power supply are designed

identical to the standard AC-powered models. All Port Module, SNMP and stacking options

are available for configuration with Dual-Source Option units. Refer to the main sections of

GND CHASSIS

The functionality of the Magnum DS8016-48VDC Dual-Source Option hubs are

The Dual-Source DC power option is designed using diodes inside of the hub on

SUPPLY A+

FUSE +

GND

specifications and configuration options for the Magnum DS8016-48VDC with this Dual-

for installations where a battery plant is the power source, and where two separate power

sources are utilized in order to increase operational uptime and to simplify maintenance.

this Installation and User Guide for a detailed description of the Magnum DS8016 Hubs.

HUB

DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
GNDTerminal for “earth” or ground wire connection to the hub chassis

Source option are identical to those listed in the Magnum DS8016 Dual-Speed Hubs

C1.0 SPECIFICATIONS - FOR MAGNUM DS8016 DUAL-SPEED HUBS

Power Consumption: Model DS8016: 25 watt typical, 40 watts max.

InputTwo separate sources, each at 36 - 70 VDC (auto-ranging)

C2.0 MAGNUM DS8016 (48VDC DUAL-SOURCE POWER OPTION)

Installation and User Guide, including Appendix A “Optional 48VDC Power”

APPENDIX C: Optional 48V Dual-Source DC Power, Addendum

C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION

Power Supply (Internal, 48VDC Dual-Source model)

A-

B-

B+

each DC power input line. A diode is placed

four external power connection terminals) so

that power from an external source can only

applied to either or both of the two inputs.

in each of the four input lines (behind the

flow into the hub. This allows the hub to

operate whenever DC power is correctly

Page 41 of the GarrettCom DS8016 user manual — C5.0 INSTALLATION
Page 41 · click to enlarge
Page 41

a) The hub can receive power from either input, “A” or “B”. The hub will normally draw

power supply) because of the blocking action of the diodes. This is true even if one input

e) The hub will not receive power (and will not work) when both inputs are simultaneously

This section describes the proper connection of the 48VDC dual source leads to the

identified as positive (A+), negative (A-), and the secondary power terminals as negative (B-

1. Minimum 14 AWG cable for connection to a Centralized DC power source. 2. Fastening torque of the lugs on the terminal block: 9 inch pound max. 3. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within

its power from the DC source with the highest voltage (in the 36-70V range) at a given

c) When one correct DC input is present, the hub will receive power if the other DC input

d) Reverse polarity connections, if they should accidentally occur on either input, will not

f) This product shall be provided with a Listed fuse or circuit breaker, rated 5 A, in the

48VDC power terminal block on the Magnum DS8016 hub (shown in Figure C4.0). The 48VDC terminal block on the Magnum DS8016 is located on the right rear of

b) The hub will not allow power to flow from a higher voltage input to a lower voltage

the unit and is equipped with five (5) screw-down lead posts. The primary terminals are

hub power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is

damage the hub or power supply internally (nor will it blow the fuse in the internal

optional, as this terminal connects to the hub chassis. Ensure that each lead is securely

is absent, or even if it is connected with reverse polarity or shorted or grounded.

The following must be adhered to in order to conform to UL requirements:

GND 36-70VDC

C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN

36-70VDC

connection is reversed while the hub is operating from the other source.

A+ AB- B+

input, i.e. the two DC power sources are not mixed together by the hub.

supply circuit when connected to a 48 V centralized dc source.

), positive(B+), and the chassis “earth” or ground (GND).

48VDC with Dual-Source option

absent or are both incorrectly connected.

Source, wiring connections to the External

The connection procedure is straightforward.

Simply connect the DC leads to the Magnum

Terminal Block on a Magnum DS8016

Figure B5.048V DC Dual-

6 inches of the terminal block.

C5.0 INSTALLATION

C6.0 OPERATION

C5.1 UL Requirements

tightened.

time.

Page 42 of the GarrettCom DS8016 user manual — APPENDIX C: Optional 48V Dual-Source DC Power, Addendum
Page 42 · click to enlarge
Page 42

identical to that of the standard models. Please refer to the applicable sections of

Operation of the Dual-Source Magnum DS8016-48VDC hub models is

the “Installation and User Guide” for more information on the basic hubs.

Ask about the GarrettCom DS8016

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom DS8016

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom DS8016 manual PDF

42 pages·471 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…