EN
GarrettCom logo
Official user manual

GarrettCom DS60s

39 pages·553 KB·Switch·PDF·ENDEFRITNLJA
GarrettCom DS60s
Table of Contents 46 sections Rev D 06/02: Add 24VDC power option in Appendix B · Rev C 11/01: Change the company name to GarrettCom, Inc. (Fo · 1.0 SPECIFICATIONS · 1.1 Technical Specifications · … ShowHide
Rev D 06/02: Add 24VDC power option in Appendix Bp.4Rev C 11/01: Change the company name to GarrettCom, Inc. (Fop.41.0 SPECIFICATIONSp.61.1 Technical Specificationsp.61.2 Ordering Informationp.82.0 INTRODUCTIONp.82.1 Inspecting the Package and Productp.92.2 Product Descriptionp.102.2.1 Magnum DS60F Dual-speed Hubs Plus, with Fiber Switchedp.112.2.2 Fiber port, SC Connector for Model DS60Fp.122.2.3 Magnum DS60C Dual-speed Hubs Plus with Copper port, Chp.122.2.4 Port #6: Switched 10/100 Mb/s Port for DS60C onlyp.132.2.5 Magnum DS50 Dual-speed Hubs Chassisp.132.2.6 Ports 1-5: 10/100 Mb/s Shared Ports for DS50 / DS60p.142.2.7 10 / 100 Speed Auto-sensingp.142.2.8 Bridge logic between the 10 Mbps and 100Mbps Domainsp.152.2.9 Up-link Switch for Cascadingp.152.3 Frame Buffering and Latencyp.162.4 Features and Benefitsp.182.5 Applicationsp.193.0 INSTALLATIONp.223.1 Locating the Magnum DS50 / DS60 Dual-speed Hubs Plusp.223.1.1 Table-Top or Shelf Mountingp.223.1.2 Optional mounting methods, DIN-rail and E-Standp.233.2 Ethernet Media, connections and Specificationsp.233.2.2 Connecting Fiber Optic SC-type, "Snap-In"p.243.2.3 Connecting Single-Mode Fiber Opticp.253.2.4 Power Budget Calculations for DS60F Fiber Mediap.253.2.5 Connections to NICs which support Auto-Negotiation, RJp.263.2.6 Collision Domain Diameterp.263.3 Powering the Magnum DS50 / DS60p.294.0 OPERATIONp.304.1 Dual-Speed Functionalityp.304.2 Auto-negotiation and speed-sensingp.324.3 Switching Functionality for port # 6 (DS60s Only)p.324.4 LEDsp.334.5 (FF-A) Manual Switch, Port 6 for DS60Cp.334.6 (F-H) Manual Switch, Port 6 for DS60Fp.344.7 Up-link Switch, Port 1p.345.0 TROUBLESHOOTINGp.355.1 Before Calling for Assistancep.355.2 When Calling for Assistancep.365.3 Return Material Authorization (RMA) Procedurep.365.4 Shipping and Packaging Informationp.37APPENDIX A: WARRANTY INFORMATIONp.37APPENDIX B : Optional 24VDC or -48VDC Power Supplyp.38
Page 1 of the GarrettCom DS60s user manual — Dual Speed Hubs Plus
Page 1 · click to enlarge
Page 1
GarrettCom DS60s diagram (page 1)
Fig. 1

Dual Speed Hubs Plus

Installation and User Guide

Magnum DS50 / DS60s

GarrettCom DS60s — Dual Speed Hubs Plus diagram (page 1)
Fig. 2 · Dual Speed Hubs Plus
GarrettCom DS60s — Dual Speed Hubs Plus diagram (page 1)
Fig. 3 · Dual Speed Hubs Plus
Page 2 of the GarrettCom DS60s user manual — Dual Speed Ethernet Hubs Plus
Page 2 · click to enlarge
Page 2

Magnum DS50 / DS60, consult Section 5, Troubleshooting, of this User Guide.

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

serviceable parts. Attempted service by unauthorized personnel shall render

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a

any and all warranties null and void. If problems are experienced with a

of this publication may be reproduced without prior written permission from

Dual Speed Ethernet Hubs Plus

Installation and User Guide

Magnum ™ DS50 / DS60s

Copyright © 2002 GarrettCom, Inc. All rights reserved. No part

Part #84-00055 (Rev C 10/01)

UL is a registered trademark of Underwriters Laboratories

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

registered trademark of GarrettCom, Inc.

Printed in the United States of America.

GarrettCom, Inc.

Trademarks

Page 3 of the GarrettCom DS60s user manual — Phone (510) 438-9071
Page 3 · click to enlarge
Page 3

TABLE OF CONTENTS PAGE

guarantee that interference will not occur in a particular installation. If this equipment

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

and, if not installed and used in accordance with the instructions, may cause harmful

instructions, may cause harmful interfernce to radio communications. However, there

Please use the mailing address, phone and fax numbers and email address listed below:

responsible for compliance could void the user’s authority to operate the equipment.

installation. This equipment generates, uses, and can radiate radio frequency energy

B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to

- Connect the equipment into n outlet on a ccircuit different from that to

interference in a residential installation. This equipment generates, uses, and can

is no guarantee that interference to radio communications. However, there is no

determined by turning the equipment off and on, the user is encouraged to try to

Cet appareil respecte toutes les exigences du Réglement sur le matériel du

radiate frequency energy and, if not installed and used in accordance with the

does cause harmful interference to radio or television reception, which can be

- Consult the dealer or an experienced radio TV technician for help.

provide reasonable protection against harmful interference in a residential

- Increase the separation between the equipment and receiver.

This Class B digital apparatus meets all requirements of the Canadian

correct the interference by one or more of the following measures.

Websitehttp://www.GarrettCom.com

Radio Frequency Interference Statement

email [email protected]

47823 Westinghouse Dr.. Fremont, CA 94539

Phone (510) 438-9071

GarrettCom, Inc.

- Reorient or relocate the receiving antenna.

Interference-Causing Equipment Regulations.

which the receiver is connected.

Canada. Cet appareil est Classe B.

Show 4 more labels / short text on this page
Federal Communications Commission · Fax (510) 438-9072 · Canadian Emission · Contacting GarrettCom, Inc
Page 4 of the GarrettCom DS60s user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

Rev D 06/02: Add 24VDC power option in Appendix Bp.4Rev C 11/01: Change the company name to GarrettCom, Inc. (Fop.41.0 SPECIFICATIONSp.61.1 Technical Specificationsp.61.2 Ordering Informationp.82.0 INTRODUCTIONp.82.1 Inspecting the Package and Productp.92.2 Product Descriptionp.102.2.1 Magnum DS60F Dual-speed Hubs Plus, with Fiber Switchedp.112.2.2 Fiber port, SC Connector for Model DS60Fp.122.2.3 Magnum DS60C Dual-speed Hubs Plus with Copper port, Chp.122.2.4 Port #6: Switched 10/100 Mb/s Port for DS60C onlyp.132.2.5 Magnum DS50 Dual-speed Hubs Chassisp.132.2.6 Ports 1-5: 10/100 Mb/s Shared Ports for DS50 / DS60p.142.2.7 10 / 100 Speed Auto-sensingp.142.2.8 Bridge logic between the 10 Mbps and 100Mbps Domainsp.152.2.9 Up-link Switch for Cascadingp.152.3 Frame Buffering and Latencyp.162.4 Features and Benefitsp.182.5 Applicationsp.193.0 INSTALLATIONp.223.1 Locating the Magnum DS50 / DS60 Dual-speed Hubs Plusp.223.1.1 Table-Top or Shelf Mountingp.223.1.2 Optional mounting methods, DIN-rail and E-Standp.233.2 Ethernet Media, connections and Specificationsp.233.2.2 Connecting Fiber Optic SC-type, "Snap-In"p.243.2.3 Connecting Single-Mode Fiber Opticp.253.2.4 Power Budget Calculations for DS60F Fiber Mediap.253.2.5 Connections to NICs which support Auto-Negotiation, RJp.263.2.6 Collision Domain Diameterp.263.3 Powering the Magnum DS50 / DS60p.294.0 OPERATIONp.304.1 Dual-Speed Functionalityp.304.2 Auto-negotiation and speed-sensingp.324.3 Switching Functionality for port # 6 (DS60s Only)p.324.4 LEDsp.334.5 (FF-A) Manual Switch, Port 6 for DS60Cp.334.6 (F-H) Manual Switch, Port 6 for DS60Fp.344.7 Up-link Switch, Port 1p.345.0 TROUBLESHOOTINGp.355.1 Before Calling for Assistancep.355.2 When Calling for Assistancep.365.3 Return Material Authorization (RMA) Procedurep.365.4 Shipping and Packaging Informationp.37APPENDIX A: WARRANTY INFORMATIONp.37APPENDIX B : Optional 24VDC or -48VDC Power Supplyp.38
Page 5 of the GarrettCom DS60s user manual — OVERVIEW
Page 5 · click to enlarge
Page 5

Magnum DS50 & DS60s Dual Speed Hubs Installation and User Guide (06/02)

6K25 Managed Fiber Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports, mix- and match. Features SFF fiber for up to 25 fiber ports in a 1U unit.

GarrettCom offers the Magnum line of Ethernet LAN connectivity products with

industry-standard functionality. Magnum products are available worldwide

through OEMs, integrators, representatives, retailers and international

4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto- negotiating full switching performance.

Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed and

Stackable Concentrators, SNMP optional, 13-Ports

Transceivers, 10Mb series Mini-Transceivers and Coax Models June, 02

ETHERNET CONNECTIVITY PRODUCTS

“Outdoor” Ethernet Switch, for temperature uncontrolled locations

"DESIGNED AND MANUFACTURED IN THE USA"

Mixed-Media Fiber Hub, 16-port Stackable,10/100 auto-sensing

Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing

The Magnum Line

6 10/100 and 2 100Mb fiber ports, can be connected in strings

8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series

10Mb series and 100Mb series, both w/ optional port modules Personal Switches, 10/100Mb

All media combinations, incl. fiber ST, SC, mm., single mode

Repeater Port Modules (RPMs), 6 types for Ethernet media

Bridge Port Modules (BPMs), 4 types, for segment isolation

The “X-line” of configurable MiXed Media products:

OVERVIEW

8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb

Mini-Concentrators, 7 Ports, Repeaters, 2-Ports

mixed-media types, full switching performance.

8-port, with two switched ports (1 fiber built in)

Stackable Hubs, SNMP Optional

Personal Hubs, 10Mb series

distributors.

Page 6 of the GarrettCom DS60s user manual — Performance
Page 6 · click to enlarge
Page 6
Date Rate10Mbps or 100Mbps (Depends upon the connected
Packet buffers256 dynamically allocated and shared on ports #1-5

10BASE-T (unshielded twisted pair, 10Mb) - 100 m (328 ft)

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

Switch = “100”, 148,800 pps max

Filtering and Forwarding Rate: Switch = “10”, 14,880 pps max.

speed on the other side; if the connected unit supports auto-

100BASE-FX, full-duplex(single-mode, long)- 40.0 km (131,240 ft)

negotiate then run on full-duplex otherwise half-duplex)

100BASE-TX (Cat. 5 twisted pair, 100Mb) - 100 m (328 ft)

100BASE-FX, full-duplex(single-mode) - 20.0 km (65,620 ft)
Ambient Relative Humidity5 % to 95 % (non-condensing)

Packet Processing on Repeater Port, ports #1-5 bridged

Latency (not including packet time)5 µ s
100BASE-FX, half-duplex(multi-mode) - 412 m (1350 ft)
100BASE-FX, full-duplex(multi-mode) - 2.0 km (6,562 ft)
100BASE-FX, half-duplex(single-mode) - 412 m (1350 ft)
Storage Temperature-5 º F to 160 º F (-20 º C to 70 º C)
Ambient Temperature32 º F to 122 º F (0 º C to 55 º C)
PDV (Path Delay Value)50BT (end node)
Port 1-5Repeater Ports, with bridge between
Packet buffers1MB dynamically allocated

Packet Processing on Switched Port, port 6

Latency (not including packet time)5 µ s
Processing typeadvertising and sharing
Data Rate10/100 Mbps (Dual-Speed)
Data Rate100 Mbps Full Duplex
Ethernet IEEE 802.3u100BASE-TX
Processing typeStore and Forward

Maximum Ethernet Segment Lengths

Port 6Switched Port (DS60C only)
PDV (Path Delay Value)80BT

IEEE 802.3: 10BASE-T

Auto-learning8K addresses
Auto-learning2K addresses

1.1 Technical Specifications

When set to “FF”:

1.0 SPECIFICATIONS

When set to “A”

Performance

10/100Mbps (Dual-Speed) · Operating Environment · Network Standards

Page 7 of the GarrettCom DS60s user manual — Power Supply (Internal) AC
Page 7 · click to enlarge
Page 7
Port 6 only (DS60C )Thumb-operated slide switch FF-A, The port #6 switched
Port 1 only, UP-LINKMDI-X thumb-operated slide switch, converts RJ-45

port from a regular (= position) user segment port to a crossover (X position)

Port 6 only (DS60F )Thumb-operated slide switch FDX-HDX, The port #6

switched Fiber port can be set on “Fdx” (Full-duplex, Fixed 100Mbps) or at

Dimensions: 9.1 in. D x 6.1 in. W x 1.3 in. H (23.0 cm x 15.5 cm x 3.3 cm)

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

AC Power connectorIEC-type, male recessed, rear of chassis

port can be set on “FF” (Full-duplex, Fixed 100Mbps) or at “A”(Auto-

LK/RX (port 1-5)Steady On when twisted-pair link is operational,

Three years, return to factory Made in USA

COL 100 (port1-5)Collision, flashing when collision occurs on
COL 10 (port1-5)Collision, flashing when collision occurs on

Power Supply (Internal), Optional 24VDC and -48VDC

ports 1-5 in the 100Mb collision domain.

Power Input Voltage100 to 240 VAC (auto-ranging)

ports 1-5 in the 10 Mb collision domain.

Suitable for wiring closet shelf, wall or desktop mounting.

Power Consumption: typical 6 watts, 10 watts max.

Power Consumptionsame as for AC models, see above

flashing when port is receiving data

-48VDC Power Input Voltage36 to 72 VDC
DC-DC Converter Rating5VDC, 2Amps

Hdx (Half Duplex) to provide better secure distance.

24VDC Power Input Voltage20 to 36VDC
Cooling methodFan cooled, internal @ 7 cfm
Std. Terminal Block“ -, GND, + ”
PWRSteady On when power applied
Emissionsmeets FCC Part 15, Class A
Power Input Frequency47-63 Hz

negotiation) to support auto-negotiate.

Enclosure: High strength sheet metal.

100 (port 6)Speed is at 100Mbps
FDX (port 6)Port is at Full duplex

UL Listed (UL 1950), cUL, CE

Power Supply (Internal) AC

Agency Approvals (Under Test)

Weight1.55 lb. (0.7 Kg)

LED Indicators on Chassis

Manual Switches · Packaging · Warranty

Page 8 of the GarrettCom DS60s user manual — 1.2 Ordering Information
Page 8 · click to enlarge
Page 8

connectors and front-mounted LED’s. The port #6 switched

port is a separate collision domain with wire-speed (10/100)

filtering and forwarding of traffic, 1Mb dynamically allocated

selection of Full Fixed and Auto-negotiation for port #6 can

Magnum DS50 Same as Magnum DS60C, but without the switched port # 6,

Magnum DS60C Six dual speed ports, five 10/100 Dual-speed shared “hub”

packet buffers and 8K-entry self-learning address table. The

supply, up-link switch or port #1. Optionally available with

Magnum DS60F-MSC Same as DS60C except 6th port is switched

Magnum DS60F-SSC Same as DS60C except 6th port is switched

Magnum DS60F-SSC Same as DS60C except 6th port is switched

ports plus one 10/100 switched port, with shielded RJ-45

fiber port, multi-mode SC, can be set as Full duplex (by

fiber port, single-mode SC, Long reach 40Km distance

MST Conversion Special order item, convert fiber SC port to ST-type connector.

be set through manual switch. Internal universal power

default) or Half-duplex by manual switch underneath.

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

fiber port, single-mode SC, supports 20Km distance

has only the 5 repeater ports with dual speed (10/100)

Magnum DS50 / DS60 Dual-speed Hubs Plus

24VDC and -48VDC internal power supply.

GarrettCom reserves the right to change specifications, performance

characteristics, and/or model offerings without notice.

capability.

1.2 Ordering Information

Models

Page 9 of the GarrettCom DS60s user manual — 2.0 INTRODUCTION
Page 9 · click to enlarge
Page 9

notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect

the contents of this package for any signs of damage and ensure that the items listed below are

to return the unit, use the original shipping container. Refer to Chapter 5, Troubleshooting, for

Examine the shipping container for obvious damage prior to installing this product;

In the event there are items missing or damaged, contact your supplier. If you need

container. Be sure to keep the shipping container should you need to ship the unit at a later

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

date. To validate the product warranty, please complete and return the enclosed Product

Remove the Magnum DS50 / DS60 Dual-speed Hub Plus from the shipping

2 Mounting screws for use with the metal mounting brackets

1 AC Power Cord (U.S. and other 115 vac locations only)

2 Metal mounting brackets for optional vertical mounting

1 Magnum DS50 or DS60s Dual-speed Hub Plus unit

2.1 Inspecting the Package and Product

Registration Card to GarrettCom as soon as possible.

1 Installation and User Guide

1 Product Registration Card

2.0 INTRODUCTION

This package should contain:

specific return procedures.

included.

Page 10 of the GarrettCom DS60s user manual — GARRETT
Page 10 · click to enlarge
Page 10

existing network segment . . . a separate collision domain of 10Mb or 100Mb units . . . connects

speed hub. It has five 10/100Mb repeater shared ports along with a 10/100 Mbps switched port

The Magnum DS50 dual-speed hub has only the five 10/100 Mb repeater ports. Each

ideally suited for adding a Fast Ethernet workgroup to an existing 10Mb or 100Mb network. A

to port 6. For expansion of the five 10/100Mb ports, an additional 100Mbps or 10Mb hub can

traffic between each workgroup’s users and servers from the rest of the network. The Magnum

The Magnum DS60C Dual-speed Hub Plus is an easy to install, cost-effective Dual-

capability. The Magnum DS60F belongs to the same DS60’s family except the sixth port is a

port can independently identify (via IEEE 802.3u auto sensing) and accept either 100Mbps or

10Mbps Ethernet signals, adapting to match the best speed of the connected device. Each unit

has its own internal power supply. The Magnum DS50 / DS60 Dual-speed Hub Plus has two

internal traffic domains . . . one for the 100 Mb domain and one for the 10Mbps domain. The

The Magnum DS60s, because of their dual-speed capability and switched ports, are

be cascaded from port 1. Each domain can have its own local servers and other local traffic.

Thus, the DS60s can bridge-isolate one collision domain from the other, separating the local

auto-ranging power voltage (100 - 240 VAC). The 24VDC and -48VDC Power supply option

that can be configured to provide “auto-negotiating” or “Full fixed” connectivity between a

switched Fiber port at 100Mbps and can be set at Full-duplex or Half-duplex to support any

small 10/100Mb workgroup connects to the five “hub” ports while another workgroup or an

DS60s will filter and forward the packets to / from port 6 and the other ports, thereby giving

The Magnum DS50 / DS60s are available with an internal AC Power supply with

enables this product to be used in the industrial and telecom markets. The Magnum DS50 /

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

100Mbps users share the 100Mbps domain’s bandwidth and the 10 Mbps users share the

Fig. 2.2.1 Magnum DS50 / DS60 is functionally both a 10Mbps and 100Mbps in one

100Mb segment and a 10Mb segment; or between two 100Mb segments at full duplex

connectivity with Hubs or switches. The “future-proof” fiber port provides a secure

RX

FDX

longer distance advantage and eliminates the need for a media converter,

LK

10Mbps Hub 100Mbps Hub Magnum DS60

1 2 3 4 5 6

UPLINK LINK 100 LINK 100 LINK 100 LINK 100 LINK 100

more bandwidth to each domain for maximum network performance.

GARRETT

PWR

10 COL

9 10 11 12

2.2 Product Description

PWR 1 2 3 4 5 6 7 8 Magnum

10Mbps domain’s bandwidth.

GARRETT

PWR 1 2 3 4 5 6 7 8 9 1 0 11 12

GARRETT

Show 5 more labels / short text on this page
10/100 Mb/s FF-A · Personal Hub Plus · = x · 8000E Stackable · Hub
Page 11 of the GarrettCom DS60s user manual — 2.2.1 Magnum DS60F Dual-speed Hubs Plus, with Fiber Switched Port
Page 11 · click to enlarge
Page 11

100 LEDs for the unit. It also has link (LINK) and receive (RX) activity LEDs for each of the

The internal power supply is an auto ranging AC power supply for input of 115-230

DS60s are “plug and play” units enclosed in a lightweight, compact, rugged metal enclosure

hub ports and a switched fiber port. The switched fiber port is available with an SC connector

The Magnum DS60F has power (PWR) and collision (COL) LED’s and 10 and

five shared ports and for Port 6. The port #6 has a Full-duplex (FDX) and a speed (100) LED

brackets for optional wall mounting are supplied with each unit. An optional “edge- stand” is

available (See “Spare Parts Price List”) and is used for floor-mounting on carpeted surfaces.

suitable for office, lab and industrial sites. The DS50 / DS60s are available for horizontal or

The Magnum DS60F chassis houses one main board equipped with five

or switch. There is a manual switch “F-H” underneath the switched port #6 which provides

vac, 50/60 Hz. Optionally available are 24VDC and -48VDC for the industrial and telecom

markets. The recessed male IEC power connector is located at the right-rear. Two mounting

also. Rubber feet on the bottom provide a sturdy grip and clearance for the exhaust of the

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

2.2.1 Magnum DS60F Dual-speed Hubs Plus, with Fiber Switched Port

GarrettCom DS60s — 2.2.1 Magnum DS60F Dual-speed Hubs Plus, with Fiber Switched Port diagram (page 11)
Fig. 4 · 2.2.1 Magnum DS60F Dual-speed Hubs Plus, with Fiber…

“Full-duplex” and “Half-duplex” capability to the switched port

cooling fan.

vertical mounting (see Section 3.1).

has an internal power supply and

a small cooling fan in the bottom,

55C. The port side of the chassis

consists of five shared 10/100Mb

an up-link (UPLINK) switch next

to be used for cascading to a hub

extending ambient operation to

switched SC fiber port. There is

to Port 1, which allows this port

single-mode and long reach. It

RJ-45 ports and one 100Mb

and options of multi-mode,

Page 12 of the GarrettCom DS60s user manual — UPLINK
Page 12 · click to enlarge
Page 12

switched port on the Magnum DS60F is

steady ON to indicate LINK is operational. The speed (100) LED is ON for 100Mbps and OFF

with the device at the other end of the cable in order for these LEDs to provide valid indications

SC type (single-mode or multi-mode)

set to operate at fixed 100Mb speed for

DS60F’s fiber port is factory-built and

available either as a multi-mode SC, or

switched port and performs as a separate traffic domain, providing a high bandwidth backbone

Port 6 (the fiber port) has an “F - H” user-selectable manual switch. When set in the

On Magnum DS60F units, there are three LED’s for the switched ports. One (LK) is

A fiber cable must be connected to the 100Mb port and a proper link (LK light) must be made

a single-mode or long-reach SC connector. The 100Mb fiber port will run at 100Mbs speed at

all times with manually selected full- and half-duplex capability. The 100Mbps fiber port is a

for 10Mbps (when LINK is made). The F/H indicates full-duplex when ON. When it is OFF,

connection (no media converter is required !) and supporting long (up to 40km) fiber cable

“F” position, it forces full-duplex mode. When set in the “H” position, it forces half-duplex

guaranteed high performance. The

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

The Fast Ethernet fiber

2.2.3 Magnum DS60C Dual-speed Hubs Plus with Copper port, Chassis

Magnum DS60C Dual-speed Hubs Plus

RX

LK

FDX

1 2 3 4 5 6

LINK 100 LINK 100 LINK 100 LINK 100 LINK 100

2.2.2 Fiber port, SC Connector for Model DS60F

GARRETT

GarrettCom DS60s — 2.2.2 Fiber port, SC Connector for Model DS60F diagram (page 12)
Fig. 5 · 2.2.2 Fiber port, SC Connector for Model DS60F

UPLINK

PWR

10 COL

houses one main board for the five hub ports

bottom. The front side of chassis consists of

and for the switched port. It has an internal

power supply and a small cooling fan in the

The Magnum DS60C chassis

distances for installation versatility.

mode, still at 100Mbps speed.

operation is half-duplex.

of operating conditions.

Show 4 more labels / short text on this page
10/100 Mb/s FF-A · Personal Hub Plus · Magnum DS60 · = x
Page 13 of the GarrettCom DS60s user manual — 100 LED FDX
Page 13 · click to enlarge
Page 13

five shared 10/100Mb RJ-45 ports and one “10/100Mb switched RJ-45 port. There is an up-link

five shared ports and for Port 6. The port #6 has Full-duplex (FDX) and speed (100) LED’s too.

(UPLINK) switch for Port 1. There is a manual switch “FF-A” underneath the switched port #6

segmented from the other DS60C ports, it provides a separate collision domain. Accordingly,

the DS60C can be used as plug-and-play in practically any 10Mb or 100Mb network domain.

The Magnum DS60C has power (PWR) and collision (COL) LED’s and 10 and 100

The internal power supply is an auto ranging AC power input of 115-230 vac, 50/60

brackets for optional wall mounting are supplied with each unit. An optional “edge- stand” is

available (See “Spare Parts Price List”) and is used for floor-mounting on carpeted surfaces.

The Magnum DS50 chassis houses one main board for the five dual-speed repeater

ports. It has an internal power supply and a small cooling fan in the bottom. The front side of

Figure 2.2.3Port 6: Switched 10 or100Mb Port

upon the attached unit’s speed. See section 4.3 for more details about the 10 or 100 switch.

additional 10/100Mb segment . . . to an existing 10 or 100Mb network. Because this port is

LED’s for the unit. It also has link (LINK) and receive (RX) activity LED’s for each of the

Rubber feet on the bottom provide a sturdy grip and clearance for the exhaust of the cooling

chassis consists of five shared 10/100Mb RJ-45 ports. There is an up-link (UPLINK) switch

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

that controls and provides “full-fixed” and “Auto-negotiation” capability to the port.

Hz. The recessed male IEC power connector is located at the right-rear. Two mounting

Link LED RX LED 6

This switched port offers great flexibility in connecting the DS60C . . . as an

100 LED FDX

2.2.4 Port #6: Switched 10/100 Mb/s Port for DS60C only

FDX

RX

LK

FF-A

2.2.5 Magnum DS50 Dual-speed Hubs Chassis

Dual-speed Hub plus has Port 6 as a

switched port located on the right

10BASE-T port or as a 100BASE-

next to Port # 1, which it controls.

front panel. Because of its dual

capability, it operates either as a

TX port. The speed may depend

fan.

speed and auto negotiation

FF-A Manual Switch · For Magnum DS60C

Page 14 of the GarrettCom DS60s user manual — 2.2.7 10 / 100 Speed Auto-sensing
Page 14 · click to enlarge
Page 14

The first five ports, # 1-5 RJ-45 twisted pair ports, support auto-sensing for speed and

each of the five shared ports. Rubber feet on the bottom provide a sturdy grip and clearance for

The internal power supply is an auto ranging AC power input of 115-230 vac, 50/60

Link LED will be on when proper cable connection is made on both ends and the RX LED will

independent of the other ports. Speed-sensing is performed by the DS50 / DS60 electronics in

accordance with the standards of the IEEE 802.3u auto-negotiation standard. If the connected

The Magnum DS50 has a power (PWR) and collision (COL) LED’s and

brackets for optional wall mounting are supplied with each unit. An optional “edge- stand” is

available (See “Spare Parts Price List”) and is used for floor-mounting on carpeted surfaces.

The up-link switch for Port 1 is located on the left side and enables port 1 to either

10 and 100 LED’s for the unit. It also has link (LINK) and receive (RX) activity LED’s for

connect to a user station or to cascade with another hub or switch. See section 4.4 for more

Figure 2.2.2Ports 1-5 : Shared 10/100Mb Ports

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

Hz. The recessed male IEC power connector is located at the right-rear. Two mounting

UPLINK LINK 100 LINK 100 LINK 100 LINK 100 LINK 100

1 2 3 4 5 10/100 Mb/s

2.2.6 Ports 1-5: 10/100 Mb/s Shared Ports for DS50 / DS60

UPLINK LINK 100 LINK 100 LINK 100 LINK 100 LINK 100

1 2 3 4 5 10/100 Mb/s

100 LED

flash to indicate activity when the port is receiving data.

the exhaust of the cooling fan.

PWR

10 COL

GARRETT

Col. LED

2.2.7 10 / 100 Speed Auto-sensing

PWR

10 COL

Hubs has Ports 1-5 as shared

and an RX (receive) activity

10Mb / 100Mb ports. Each

port has its own Link LED

LED to indicate its status.

These LED’s are built into

DS50 / DS60 Dual-speed

the RJ-45 connector. The

details about up-link.

Show 10 more labels / short text on this page
Personal Hub Plus · Magnum DS60 · = x · Link LED · Uplink Switch · Power LED · = x · Magnum DS50 Dual-speed · The Magnum · Hubs
Page 15 of the GarrettCom DS60s user manual — 2.2.8 Bridge logic between the 10 Mbps and 100Mbps Domains
Page 15 · click to enlarge
Page 15

10Mbps signal (or no reply to auto-negotiation) is detected, and it will blink if the linked port is

domain, whether 100Mbps or 10Mbps, to communicate to each other. It also keeps local traffic

The unit has an up-link switch located next to Port # 1 of the hub. It enables the port’s

device or node indicates that it is capable of 100Mbps speed, then operation on that port will be

at 100Mbps. If the connected device does not positively indicate that it is capable of 100Mbps

Magnum DS50 / DS60’s contain bridge logic (in the Integrated Circuit) to interconnect the two

The bridge operates in the store-and-forward mode, which filters out bad packets and

filtering/forwarding of 10Mbps and 100Mbps packets is maintained correctly even when users

cable to cascade to another shared hub or switching hub port. (See Section 4.4 for more details

about up-link). Port # 1 is a dual-speed port that will sense the speed of the connected device.

auto-negotiation technique is only for 10/100 speed, and does not provide for any full-duplex

The per-port 10/100Mbps LK/RX LED’s on each repeater port indicate the result of

maintains optimum performance in both domains. Packet forwarding delay is only 5µs (plus

packet time). This is much less than traditional store-and-forward bridge products, enabling

speed, then the operation on that DS50 / DS60 port will be at 10Mbps. Of course, the hubs’

auto-sensed speed detection, and the resulting connectivity to either a 10Mbps or 100Mbps

device. The 100Mbps LED will illuminate (GREEN) when 100Mbps signals are detected; it

traffic domains and filter and selectively forward packets to allow only necessary packets to

DS50 / DS60’s to maintain high network performance. The bridge has a 2K node address

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

will have a steady ON if there is no traffic and it will have a blinking ON when the port

transmits and receives data packets. Similarly, for 10Mbps speed, it will be “off” when a

cross between the domains. This enables all of the users and nodes connected into either

capacity, suitable for use in medium-sized networks. Addresses are self-learning so that

2.2.8 Bridge logic between the 10 Mbps and 100Mbps Domains

on one domain from consuming any of the bandwidth from the other.

Bridge I.C.

move their connection, change speed, or power down.

2.2.9 Up-link Switch for Cascading

Figure 2.3Internal view of DS50

transmitting and receiving.

operation.

with bridge logic

Page 16 of the GarrettCom DS60s user manual — 2.3 Frame Buffering and Latency
Page 16 · click to enlarge
Page 16

segments connected. The "cut-through" technique permits collision fragment frames, which are

a result of late collisions, to be forwarded to add to the network traffic. Since there is no way to

To minimize the possibility of dropping frames on congested ports, Magnum DS60’s

have their packet buffer storage space divided evenly across all ports, resulting in a small, fixed

industry standard (full-duplex only) PAUSE packets out to the devices sending packets to cause

The Magnum DS60’s 6th port is a store-and-forward switch. Each frame (or packet)

is loaded into the Switch’s memory and inspected before forwarding can occur. This technique

ensures that all forwarded frames are of a valid length and have the correct CRC (i.e., are good

number of packets to be stored per port. When the port buffer fills up, dropped packets result.)

adapting internally to provide maximum network performance with the least dropped packets.

“flow control”. This tells the sending devices to temporarily stop sending traffic, which allows

The up-link operates the same, whether Port # 1 is connected to either a 100Mbps or 10Mbps

heavy, the result of store-and-forward operation is that more bandwidth is available for good

density per port and in aggregate density, the Magnum DS60’s Switched 6th port is constantly

When the up-link port is used to cascade two DS50 / DS60 hubs, the auto-sensing

calculated), the result of indiscriminate cut-through forwarding is greater traffic congestion,

especially at peak activity. Since collisions and bad packets are more likely when traffic is

Switched port dynamically allocates buffer space from an 1MB memory pool, ensuring that

heavily used ports receive very large buffer space for packet storage. (Many other switches

DS60’s 6th port to be applied to all traffic loads, even when the traffic activity is unbalanced

When the Switch detects that its free buffer queue space is low, the Switch sends

across the ports. Since the traffic on an operating network is constantly varying in packet

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

feature of the DS50 / DS60 will cause the connecting link to operate at 100Mbps speed.

While other switching technologies such as "cut-through" or "express" impose

minimal frame latency, they will also permit bad frames to propagate out to the Ethernet

This dynamic buffer allocation provides the capability for the maximum resources to the

a traffic catch-up to occur without dropping packets. Then, normal packet buffering and

packets). This eliminates the propagation of bad packets, enabling all of the available

filter frames with a bad CRC (the entire frame must be present in order for CRC to be

2.3 Frame Buffering and Latency

bandwidth to be used for valid information.

packets when the traffic load is greatest.

device.

Page 17 of the GarrettCom DS60s user manual — 2.3 Frame Buffering and Latency
Page 17 · click to enlarge
Page 17

flow-control mechanism (when operating at half-duplex only). When the Switch detects that its

forwarded to its destination) of the DS60’s Switched port varies with the port-speed types, and

microseconds plus the packet time at 10 Mb. For 100Mb-to-100Mb forwarding, the latency is

processing resumes. This flow-control sequence occurs in a small fraction of a second and is

Another feature implemented in Magnum DS60’sSwitched port is a collision-based

free buffer queue space is low, the Switch prevents more frames from entering by forcing a

the length of the frame is a variable here as it is with all store-and-forward switches. For 10

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

The latency (the time the frame spends in the Switch before it is sent along or

Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the latency is 15

collision signal on all receiving half-duplex ports in order to stop incoming traffic.

transparent to an observer. See Section 4.6 for additional details.

5 microseconds plus the packet time at 100Mb.

Page 18 of the GarrettCom DS60s user manual — 2.4 Features and Benefits
Page 18 · click to enlarge
Page 18

maximizes available bandwidth for both of the attached segments, enhancing network

the attached unit capability, or for Full-Fixed 100Mb FDX with no auto-negotiation..

10Mbps and one at 100Mbps -- in one physical box supporting two traffic domains.

enables it to provide secure longer cable distances, and eliminates the use of a media

converter. The fiber port is available in SC multi-mode, single mode and Long reach.

required. As nodes are added or changed, the unit learns the new network addresses

Ports 1-5 are Ethernet Repeater ports, and operate by broadcasting packets

The compact physical size of the Magnum DS50 / DS60 package allows it

both network segments from the packets in the traffic, so there is no software set-up

„ Segments 100Mb networks for high performance and simplified expansion

„ User configurable Port 6 for Auto-negotiation or Full-Fixed (DS60C only)

The Magnum DS60C sixth switched port has a manual switch underneath

the port it controls. The user can manually select port #6 to Auto-negotiation as per

repeater ports, ports 1-5 may be used for network diagnostic tools such as a sniffer.

durability, and the internal universal power supply enables one model to be usable

„ Supports 10 or 100Mbps network connections on each of six RJ-45 ports

The DS50 / DS60 Dual-speed Hub Plus learns the network addresses of

The Magnum DS60’s (only) provides a separate collision domain which

limitations and repeater hop counts to enable easy expansion of 10/100Mb nets.

worldwide. The optional DC power supply with -48VDC or 24VDC qualifies the

Each port can operate at either 10 or 100Mbps, independently of the other ports.

performance. The segmentation of the switched port 6 also resets cable distance

received to all the other hub ports operating at the same speed. Because they are

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

A Magnum DS50 / DS60 Dual-Speed hub combines two logical hubs -- one at

The Magnum DS60F model, equipped with one Switched fiber port at 100Mb,

to be installed in office or lab locations. The rugged metal enclosure provides

„ Compact Enclosure Allows for Versatile Installation with AC &DC

„ “ Future Proof” Fiber Switched port (for DS60F model only)

and adapts its filtering and forwarding of packets automatically.

„ Standard Repeater ports for network diagnostic use

DS50 / DS60s for use in Industrial and telecom applications.

„ “Plug and Play” Installation and Operation

2.4 Features and Benefits

Page 19 of the GarrettCom DS60s user manual — GARRETT
Page 19 · click to enlarge
Page 19

For this example, DS60C Port 6 may be used as a 10Mb port to an existing 10Mb hub

Figure 2.4.1DS60C for different department with high bandwidth from switch port

The Magnum Dual-speed Hub Plus is designed to provide dual speed (10/100Mbps)

operation or impacting other users. It is simple to install and use, making shared Fast Ethernet

Since 10/100 NICs are widely available at low cost, 100BASE-TX Fast Ethernet has

connectivity. Pictured below, a Magnum DS50 Dual-speed Hubs serves a small office with

become desirable for many performance-oriented users. They usually want their new 100Mb

collision domain in order to maximize performance of both segments. This is where bridged-

dual-speed provides flexibility by enabling the newly installed 100Mb ports to communicate

GarrettCom DS60s — 2.5 Applications diagram (page 19)
Fig. 6 · 2.5 Applications

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

network segment to be interoperable with existing 10Mb networks, and to be a separate

bridge logic inside. Any node can change speed at any time without affecting network

GarrettCom DS60s — 2.5 Applications diagram (page 19)
Fig. 7 · 2.5 Applications

networks practical for connecting high performance user groups in a variety of ways.

while Ports 1-5 are a new separate collision domain of shared 10/100 ports.

UPLINK LINK 100 LINK 100 LINK 100 LINK 100 LINK 100

1 2 3 4 5 10/100 Mb/s Connect to the main

PWR R

LK

FDX

1 2 3 4 5 6

1 2 3 4 5 6 7 8 POWER

UPLINK LINK 100 LINK 100 LINK 100 LINK 100 LINK 100

GARRETT

10 COL

smoothly with existing 10Mb nodes and hubs.

users operate at 100Mbps, and some

communicate to each other via the

PWR R

LK

FDX

mixed speed requirements. Some

users and utility devices (such as

print servers) run at 10Mbps. All

1 2 3 4 5 6

10/100Mb Work Stations 10

UPLINK LINK 100 LINK 100 LINK 100 LINK 100 LINK 100

2.5 Applications

share the same hub, and

UPLINK LINK 100 LINK 100 LINK 100 LINK 100 LINK 100

GARRETT

10 COL

Show 14 more labels / short text on this page
Personal Hub Plus · 10/100Mb Work Stations · Magnum DS60 · 10/100 Mb/s FF-A · = x · network · um DS60C Magn · ub Plus · FF-A 10/100 Mb/s · m DS60 · Magnu · Personal H · 10/100Mb Work Stations · = x
Page 20 of the GarrettCom DS60s user manual — 2.5 Applications
Page 20 · click to enlarge
Page 20

Consider yet another situation in Figure 2.4.3 where a new 100Mb user group is to be

The previous examples show that the Magnum DS60C Dual-speed Hub Plus not only

ports to the network, it also adds a collision domain giving configuration flexibility to the new

DS60C. All packet forwarding and filtering is done by the Magnum DS60C and is transparent

to the users, who only see one network in terms of node addresses. Performance of the network

is enhanced as the available bandwidth on each segment will not be affected by the local traffic

To add more 10/100Mb stations, another 10/100Mb workgroup can be added using a DS60C

segments the local traffic of the new and the existing segments from each other. This type of

configuration is ideal for adding a new 100Mb workgroup without slowing down the existing

hub. By placing the Magnum DS60C Dual-speed Hub Plus in the middle, it acts as a bridge

separating the 10Mb and the 100Mb traffic domains and provides each department with full

added to an existing 100Mb network. The Magnum DS60C not only provides more 100Mb

user group. The existing network can grow without having to worry about cable distance

The above figure shows two 100BSASE-TX segments connected via a Magnum

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

provides connectivity between a 100Mb workgroup and a 10Mb workgroup, but it also

100Mb Workgroup 100Mb Workgroup

GarrettCom DS60s — 2.5 Applications diagram (page 20)
Fig. 8 · 2.5 Applications
Figure 2.4.3Joining two 100Mb workgroups with a Magnum DS60C

Since the DS60C Dual-speed Hub Plus segments the network, the bandwidth

Magnum 800E Workgroup Hub 100 M b/s GARR ETT LIN K RX LIN K RX PWR COL 1 2 3 4 5 6 7 8

10Mb network with all the unwanted local packets from the new workgroup.

GARR ETT LIN K RX LIN K RX PWR COL 1 2 3 4 5 6 7 8

limitations and repeater hop counts associated with the new segment.

available for each collision domain is maximized.

UPLINK LINK 100 LINK 100 LINK 100 LINK 100 LINK 100

PWR 1 2 3 4 5 6 7 8 Magnum 8000E 9 10 11 12 Stackable Hub

on the other segment.

PWR 1 2 3 4 5 6 7 8 Magnum

PWR 1 2 3 4 5 6 7 8 Magnum

PWR 1 2 3 4 5 6 7 8 Magnum

bandwidth.

Magnum DS60C

Page 21 of the GarrettCom DS60s user manual — PWR
Page 21 · click to enlarge
Page 21

other sources. Some users operate at 100Mbps, and some users and utility devices (such as print

10Mbps network without having to change it. Nodes that are capable of 100Mbps speed can be

servers) run at 10Mbps. High performance users need a high bandwidth backbone for access to

Existing 10Mbps hub or switch users can easily be cascaded into any copper ports of

accommodating high performance data transfers, and provides fiber connectivity built-in rather

In this example, a Magnum DS60F Dual-speed Hub serves in an Industrial place with servers

a central LAN and central file servers. A Magnum DS60F Dual-speed Hub with 24VDC or -

capability and a 100Mbps Fiber port makes the required setup simple. Any attached node can

and mixed-speed requirements, such as collecting data or downloading data from servers or

bandwidth of the 10Mbps domain, so overall performance of the network is sustained at the

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

the DS60F. This allows a simple plug-and-play addition of 100Mbps port to an existing

change speed at any time without affecting network operation or impacting other users.

than needing an auxiliary media converter unit. The 100Mbps traffic does not use the

48VDC power supply serves this requirement economically. The five dual-speed port

The 100Mb Full-duplex (default) fiber port on the DS60F can be used for

Fig 2.4.4 DS60s in Industrial use for collecting data from the M/C

moved to a DS60F port, and will automatically operate at the higher speed.

LK

100/10 FDX/HDX

ACT

GarrettCom DS60s — LK diagram (page 21)
Fig. 9

LINK RX LINK RX PWR COL

1 2 3 4 5 6 7 8

LINK 100 LINK 100 LINK 100 LINK 100 LINK 100

highest possible level.

FDX

1 2 3 4 5 6

LINK 100 LINK 100 LINK 100 LINK 100 LINK 100

GARRETT

LINK 100 LINK 100 LINK 100 LINK 100 LINK 100

PWR

UPLINK

10 COL

Show 14 more labels / short text on this page
from M/C · Internet · Router · 10Mb network · Magnum 800E · orkgroup Hub W · 100 Mb/s GARRETT · Personal Hub Plus · Magnum DS60 · 10/100 Mb/s FF-A · = x · Collecting Data · Collecting Data · from M/C
Page 22 of the GarrettCom DS60s user manual — GARRETT
Page 22 · click to enlarge
Page 22

space around the rubber feet should be kept clear. (An optional floor stand for edge-mounting is

The location of the Magnum DS50 / DS60 Dual-speed Hub Plus is dependent on the

physical layout of the network and the workgroup to be bridge-isolated. The compact size of

Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum

Magnum DS50 / DS60 will normally protect it from accidental damage in a lab or workplace

The Magnum DS50 / DS60 Dual-speed Hub Plus can be easily mounted on a table-

top or any suitable horizontal surface. It also has four rubber feet to provide stability without

the unit allows it to be table-top, shelf or wall-mounted. Brackets for vertical mounting are

DS50 / DS60 site. (For optional DC power, see Appendix B). The rugged metal case of the

This chapter provides instructions for installing the Magnum DS50 / DS60 Dual-

included. The cooling fan in the bottom of the unit exhausts air underneath the unit, so the

available - see GCI’s Spare Parts List - and this stand is recommended for use on carpeted

3.1.2 Wall (or Vertical Surface) Mounting

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

setting. Keep an open area around the unit so that cooling can occur while the unit is in

scratching finished surfaces. Air from the cooling fan exhausts to the underneath side.

Proper mounting bracket attachment

3.1 Locating the Magnum DS50 / DS60 Dual-speed Hubs Plus

GARRETT

UPLINK

PWR

10 COL

3.1.1 Table-Top or Shelf Mounting

mounting brackets al

Magnum DS60C, option

3.0 INSTALLATION

Personal HubTM Plus

speed Hub Plus.

GARRETT

operation.

floors.)

Show 4 more labels / short text on this page
100 Mb/s · = x · Magnum DS60 · 100 Mb/s
Page 23 of the GarrettCom DS60s user manual — PWR
Page 23 · click to enlarge
Page 23
three media types100BASE-TX, 10BASE-T and 100BASE-FX. CAT 5 cables should be used

bracket. When properly attached, the brackets will extend slightly below the base of the unit to

3.1.1 above) to attach DIN-rail clips that hold the unit in a vertical position, Ethernet cables attaching at the bottom. For additional information on DIN mounting, email

DS50 / DS60. The E-Stand also allows the DS50 / DS60 unit to be securely mounted

when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3

bracket. It is recommended that the brackets be attached to two opposite corners on the unit.

The Magnum DS50 / DS60 Dual-speed Hub Plus can be connected to the following

may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100

meters (328 ft). For fiber port 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling

Each Magnum DS50 / DS60 Dual-speed Hub Plus is shipped with two mounting

position. The brackets are attached to the unit’s case with one of the metal screws for each

The brackets should be attached to the Magnum DS50 / DS60 through the round hole of the

A) For DIN-rail mounting, a kit is needed that uses the metal mounting brackets (see

align the rectangular cut-out on the E-Stand with the air vent on either side of the

can be used, whereas for single-mode, 9/125 microns cabling should be used. Fiber cabling

supports much longer cable distance and higher bandwidths as compared to copper wiring.

brackets (and screws), to allow the unit to be mounted in nearly any desired orientation or

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

via two screws that connect through the E-Stand and into the side of the unit.

1 2 3 4 5 6

= x 10 100

COL

LINK

LINK RX LINK RX LINK RX LINK RX LINK RX RX

PWR

GARRETT

3.1.2 Optional mounting methods, DIN-rail and E-Stand

3.2 Ethernet Media, connections and Specifications

support@GarrettCom.com

possible or desirable (such as

vertical mounting option for

when the unit is placed on a

carpeted floor, which would

from the cooling fan), the E-

horizontal placement is not

installation option. Simply

allow clearance for the rubber feet.

B) The E-Stand provides a

the DS50 / DS60s. When

potentially block air flow

Stand offers a convenient

Show 7 more labels / short text on this page
(Air Vent) · UPLINK Mb/s · Personal Hub Plus · Magnum DS60 · Rectangular · Screw holes · cut-out
Page 24 of the GarrettCom DS60s user manual — 3.2.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or
Page 24 · click to enlarge
Page 24

not help, ensure that the cable is connected properly and that the device on the other end

100Mbps) be used whenever possible in order to provide flexibility in a mixed-speed network (since DS50 / DS60 hub ports are auto-sensing for either 10 or 100Mbps).

1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either
2. Connect the other end of the cable to the corresponding device. 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established. If this does
1. Before connecting the fiber optic cable, remove the protective dust cap / plug from the

at regular intervals; you should use the color-coded strand on the associated ports

3. Connect the Transmit (TX) port on the Magnum Fiber port to the Receive (RX) port of
4. Connect the Receive (RX) port to the Transmit (TX) port of the remote device. Use the

The following procedure describes how to connect a 10BASE-T or 100BASE-TX

The following procedure applies to installations using SC-type fiber connectors. This

end of the fiber connectors, exposing the ports opening. Save the dust cover / plug for

dampened in alcohol. Make certain the connectors are clean before connecting. Then,

the remote device. Begin with the color-coded strand of the cable for this first TX-to-

insert the square male connector into the SC female jack of the Fiber port connector

4. For Port # 1 or 1SW, if the LINK LED is not illuminated, move the switch which has a cross-over or up-link for linking to another hub or Switch.
2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue

RX connection. Note – the two male square-end SC cable strands may be fastened

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

3.2.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or

Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45

twisted pair segment to the RJ-45 port. The procedure is the same for both

Twisted Pair (CAT 5) 100BASE-TX RJ-45

Media IEEE Standard Connector

future use, in case the fiber cable needs to be unplugged for service.

Fiber (Multi-mode) 100BASE-FX SC

Fiber (Single-mode) 100BASE-FX SC

procedure applies to ports using multi-mode SC fiber connectors.

3.2.2 Connecting Fiber Optic SC-type, "Snap-In"

unshielded or shielded cables and wiring may be used.

at each end of the fiber optic cable segment.

unshielded and shielded twisted pair cables.

non-color coded fiber strand for this.

is powered and is not defective.

until it clicks and secures.

together to plug as a unit.

Shielded)

Page 25 of the GarrettCom DS60s user manual — DS60F-
Page 25 · click to enlarge
Page 25

diameters of the core and the core plus the cladding respectively). Single-mode fiber allows full

mode 20 (0.4) 1300 9/125 -15 -31 14 28 17.5 35

mode 40 (0.4) 1300 9/125 -5 -34 27 54 32.5 65

connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (9/125

The same procedures as for multi-mode fiber apply to single-mode fiber connectors.

Receiver Sensitivity and Transmitter Power are the parameters necessary to compute

-31 9.0 5.5 2.5 2.0 14 12 5 4

  • The worst-case OPB of the fiber link must be greater than the fiber cable’s passive

The following data has been collected from component manufacturer’s (HP’s and Siemens’)

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following

5. The LINK LED for the fiber connector will illuminate when a proper connection has

been established at both ends (and when power is ON in the unit). If LINK is not lit

after cable connection, the normal cause is improper cable polarity. Swap the fiber

the power budget. To calculate the power budget of different fiber media installations using

microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

OPB,

When using single-mode fiber cable, be sure to use single-mode fiber port

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

  • The 100Mb fiber segment must operate in full-duplex (FDX) mode, and

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

web sites and catalogs to provide guidance to network designers and installers.

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

where the “Cable Loss” for 62.5/125 and 50/125µm (m.m.) is 2.8 dB/km,

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

OPB,

bandwidth at longer distances, about 20Km with the single-mode SC.

3.2.4 Power Budget Calculations for DS60F Fiber Media

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

PR ,dB

Sens.

-23.5 -31

cables at the fiber connector to remedy this situation.

Magnum products, the following equations should be used:

PT , dB

mode 2 (0.4) 1300 62.5/125 50/125 -20

3.2.3 Connecting Single-Mode Fiber Optic

OPB (Optical Power Budget) = PT(min) - PR(min)

Follow the steps listed in Section 3.2.2 above.

Mode Std. km

factors are both applied:

xMSC 100Mb FX Multi-

Attenuation.

Std.

DS60F-

DS60F-

Show 30 more labels / short text on this page
Km, fdx · typical* · distance · typical · dB · Worst* · distance · Km, fdx · Worst · dB · R’cvr · X’mitr · Output · Cable · Size · µm · Wave- · length · nm · fdx · (hdx) · 100Mb FX Single- · 100Mb FX Single- · Speed, · Fiber · Port · Module · xSSC · “Long · Reach”
Page 26 of the GarrettCom DS60s user manual — 3.2.6 Collision Domain Diameter
Page 26 · click to enlarge
Page 26

devices that are connected by means of a repeater or repeaters such that no bridging devices are

communicating with a protocol other than 100BASE-TX (such as 10BASE-T). When 100Mb

In cases where 100BASE-TX connection ports are used as 10BASE-T ports, CAT 3

100Mbps) be used whenever possible in order to provide flexibility in a mixed-speed network, since dual-speed ports are auto-sensing for either 10 and 100Mbps. Note

Fast Ethernet network, the collision domain, regardless of the actual network topology, must be

coding for the 100BASE-TX signaling system. When connecting a NIC to a DS50 / DS60, it

speed is agreed and in use, the 10/100 LED is steady ON. It is OFF if there is no traffic or if

may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100

present between any two devices in the cluster. In order to install an IEEE 802.3u compliant

(Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse (FLP)

The Collision Domain Diameter is the length of the longest path between any two

less than 512 BT (Bit Times). Bit Times are related to media types as shown in Table 3.2a.

Fiber Optic 1.000 Shielded TP cable 1.112 Category 5 Cable 1.112 Category 4 Cable 1.140 Category 3 Cable 1.140 *Worst case delays taken from IEEE Std 802.3u-1995, actual delays may be less for a particular cable. Contact your cable supplier for exact cable specifications.

3.2.5 Connections to NICs which support Auto-Negotiation, RJ-45 ports

devices in a single collision domain. A collision domain is defined as a cluster of network

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

The copper ports of Magnum DS50 / DS60s will function properly with NICs

Twisted Pair (CAT 3 or 5) 10 BASE-T RJ-45

Twisted Pair (CAT 5) 100BASE-TX RJ-45

Table 3.2aWorst case round-trip delay for Fast Ethernet media*

may be necessary to reload the NIC drivers on the user device if the NIC has been

Media IEEE Standard Connector

Media Type Round-trip delay in

Bit Time per Meter (BT/m)

that the auto-sensing function does not sense the cable type.

3.2.6 Collision Domain Diameter

there is 10Mbps traffic.

meters (328 ft).

Page 27 of the GarrettCom DS60s user manual — LINK
Page 27 · click to enlarge
Page 27

domain diameter specification, the following formula should be applied to the worst case path

IEEE standard, this value must be less than 512 BT. The safety margin is specified in BT and

may be a value between 0 and 5. This margin can be used to accommodate unexpected delays,

through the network. The worst case path is the path between the two Fast Ethernet devices

PDV is the Path Delay Value of the worst case path. For the network to adhere to

depends on the physical signaling system employed. Table 3.2b shows each Fast Ethernet

Table 3.2bWorst case round-trip delay for Fast Ethernet device components*

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

Each Fast Ethernet device component also has an associated BT delay, which

To determine whether a prospective network topology adheres to the collision

device component and the associated BT delay. Note that there is only one DTE pair

GarrettCom DS60s — 3.2.5 Connections to NICs which support Auto-Negotiation, RJ diagram (page 27)
Fig. 10 · 3.2.5 Connections to NICs which support Auto-Negotia…

as seen when using extra long patch cables. A safety margin from about 2 to 4 BT is

combination of TX and FX ports 92 **Note, the delay is only 80 Bit Times for the MagnumDS50 / DS60, ports 1-5.

PDV = (sum of cabling delays) + (sum of repeater delays) +

LINK

RX PWR COL

Cat. 5 cable for

2 TX DTEs 100 2 FX DTEs 100 1 FX and 1 TX DTE 100 2 T4 DTEs 138 1 T4 and 1 TX or FX DTE 127 Class I Repeater 140 Class II Repeater with any

(DTE pair delay) + (safety margin)

100 m cat. 5 cables to user devices

*Worst case delays taken from IEEE Std 802.3u-1995.

LINK

RX PWR COL

(DTEs) which have the longest round trip time.

associated with any device-to-device path.

right. The example is illustrated in

A typical example of a

standard Fast Ethernet hubs with

PDV calculation is shown to the

Figure 3.2a. Here, an integrator

wishes to cascade two industry-

100m Category 5 user segments

(i.e., from computer to hub) and

recommended.

Show 7 more labels / short text on this page
Industry- · Standard · 100Mb/s Hub · cascading · Industry- · Standard · 100Mb/s Hub
Page 28 of the GarrettCom DS60s user manual — X < 5.6 BT
Page 28 · click to enlarge
Page 28

one collision domain’s cable lengths. If used, port 6 of the Magnum DS60C when set to 100Mb

92BT), the integrator can cascade three Magnum hubs with the maximum user cable lengths.

The calculation is shown below. The variable “X” is used to represent the unknown maximum

Where 111.2 is the BT delay for 100m of Category 5 cable (1.112 BT/m* 100m), 60 is the BT

margin of 0 was used. (Note the internal switch on port 6 does not enter into this calculation of

not exceed 8 meters may be used to cascade the three Magnum DS50 & DS60’s. Note that this

Table 3.2c shows maximum cable lengths for common network configurations. The

needs to know the total length of the Category 5 cable used to cascade the hubs. The variable

The resulting value tells us that two Category 5 cables whose combined lengths do

delay for each of the Magnum hubs, 100 is the BT delay for the TX DTE pair, and a safety

cable length may alternatively be increased by shortening the lengths of the 100m cables to

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

If the integrator uses Magnum hubs, he can increase the length of the cascaded

Additionally, as the Magnum hubs have a lower delay value (60BT rather than

⇒ 8.63 m maximum total length for Category 5 cascading segments,

PDV = X + ((111.2 + 111.2) + (60 + 60 + 60) + (100) + 0 ) BT < 512 BT

PDV = X + ((111.2 + 111.2) + (92 + 92) + (100) + 0 ) BT < 512 BT

above calculations should be performed for calculations not listed in the table.

⇒ 5.03 m maximum length for Category 5 cascaded cable

“X” is used to represent the unknown maximum cascade length.

has a PDV of 50BT, the same as a NIC or node.).

X < (5.6 BT) / (1.112 m/BT)

X < (9.6 BT) / (1.112 m/BT)

512 > (X + 506.4) BT X < (512 - 506.4) BT

512 > (X + 502.4) BT X < (512 - 502.4) BT

X < 5.6 BT

X < 9.6 BT

X < 5.03 m

X < 8.63 m

cascade length.

segment.

users.

Page 29 of the GarrettCom DS60s user manual — 3.3 Powering the Magnum DS50 / DS60
Page 29 · click to enlarge
Page 29

Each DS50 / DS60 auto-ranging power supply supports installation environments where

the AC voltage is from 100 to 240 volts with an input frequency between 47 and 63 Hz, and

GarrettCom DS60s — 3.3 Powering the Magnum DS50 / DS60 diagram (page 29)
Fig. 11 · 3.3 Powering the Magnum DS50 / DS60

100-240 vac, 47-63 Hz

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

Table 3.2cMaximum segment lengths for common network configurations

2 2 79.5 1.0 1 hub T4, 1 hub TX and T4 (class I repeater), all cables

AC Power: Auto-ranging

In order to power down the unit, simply unplug either end of the power cable.

supplied with each unit shipped within the United States and Canada.

3.3 Powering the Magnum DS50 / DS60

connector for the AC power cord at the right-

Hub Plus incorporates an internal universal

power supply and has a recessed male IEC

rear. A six-foot 115vac 60Hz power cord is

Magnum DS50 / DS60 Dual-speed

consumes a maximum of 20 watts.

Page 30 of the GarrettCom DS60s user manual — 4.0 OPERATION
Page 30 · click to enlarge
Page 30

traffic domains separately. The DS50 / DS60 provides switched (bridged) connectivity between

taken to either filter or forward the packet. Error packets are always filtered. For good packets,

the filter and forward decisions are made based on the destination addresses contained in each

packet. If the destination address is on the same domain from which the packet originated, then

it is filtered and not forwarded to the other domain. If the destination address is not found to be

domain. If it is a new node address coming in which the switch did not previously know about,

it “learns” the new address and puts it in the correct port address table. See “Address Learning”

100Mbps Domain100Mbps packets are

The repeater ports (port #1-5) of a Magnum DS50 / DS60 handles the two different

This diagram below shows the filter / forward logic for both domains at port # 1-5.

Figure 4.1Filtering and Forwarding at port (1-5) in DS50 / DS60 Dual-speed Hubs

bandwidth utilization and performance. The Magnum DS50 / DS60 is a hardware plug-and-

filtered when the destination address is

in the 100Mbps domain address table.

This chapter describes the function and operation of the Magnum DS50 / DS60.

domains for unified operation and filters/ forwards packets in both directions to maximize

play device. There is no software set-up to be done at installation or for maintenance. The

Each time a packet is received on one domain of the bridge logic, the decision is

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

the Ethernet (10Mbps) and Fast Ethernet (100Mbps) domains. It joins the two network

a match in the address table for the originating domain, then it is forwarded to the other

NOT in the 10Mb domain address table. 100Mbps Domain : 100Mbps packets are

forwarded when the destination address is

NOT in the 100Mb domain address table.

Magnum DS50 / DS60

functions of the DS50 / DS60 is described in this manual.

10Mb Domain10Mbps packets are forwarded when the destination addresse is

Bridge I.C.

4.1 Dual-Speed Functionality

10Mbps Domain10Mbps packets are

filtered when the destination address is

4.0 OPERATION

in the 10Mbps domain address table.

for more details.

Show 4 more labels / short text on this page
100 Mbps Domain · 100 Mbps Traffic · 10 Mbps Domain · 10 Mbps Traffic
Page 31 of the GarrettCom DS60s user manual — 4.0 OPERATION
Page 31 · click to enlarge
Page 31

address table capacity of 2K addresses. With a large address table, a Magnum DS50 / DS60 can

are routinely processed. The address tables are flushed periodically to update the network status

the users on both sides of the network. As shown in Figure 4.1, it keeps the local traffic on each

The Magnum DS50 / DS60 bridge logic is a state machine design which has a total

action the Magnum DS50 / DS60 will take in each packet-processing situation and when a new

its switching (bridging) logic, the Magnum DS50 / DS60 increases the available bandwidth for

domain and using up bandwidth needlessly. This results in more available network bandwidth

comes into a port for the first time, then the new source address is “learned” at the same time

that the packet is forwarded. After learning, subsequent packets from the same node address

By selectively forwarding packets from each domain to the other domain based on

node address will be added to the internal Address Table. When a new node-address packet

side contained, preventing unnecessary packets and bad packets from traveling to the other

serve the needs of medium-sized to large networks. Table 4.1 shows what filter / forward

transparent to system and application software, including network management software.

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

Packet Source Destination Address Table Filter/Forward

The Magnum DS50 / DS60 Dual-speed Hub need no software set-up and is

10 Mbps Not in table Not in table Add source to table Forward

10Mbps In table Not in table None Forward

100Mbps Not in table Not in table Add source to table Forward

100Mbps In table Not in table None Forward

Source Address Address Maintenance Action

Table 4.1DS50 / DS60 Dual-Speed Hub Functionality

10Mbps Not in table In table Add source to table Filter

10Mbps In table In table None Filter

100Mbps Not in table In table Add source to table Filter

100Mbps In table In table None Filter

2. Address Learning (Address Table Maintenance)

on both sides and a throughput increase for all users on both domains.

and to purge any inactive stations from the tables of both domains.

3. Throughput Increase
4. Software Transparency
Page 32 of the GarrettCom DS60s user manual — 4.2 Auto-negotiation and speed-sensing
Page 32 · click to enlarge
Page 32

When the ‘10 M LINK/ACT’ LED is ON, either steady or blinking (see below),

100Mbps for Fiber media to maximize bandwidth utilization, network performance and secured

as Half-duplex through the manual switch underneath the port it controls. The internal functions

Each time a packet arrives on one of the switched ports, the decision is taken to either

IEEE802.3 standard). Similarly, when the ‘100M LINK/ACT’ LED is lit, it means 100Mbps

maximize bandwidth utilization and network performance. Similarly Magnum DS60F supports

Magnum DS60 units are plug-and-play devices. There is no software configuring to

port it controls. Similarly the Fiber switched port at 100Mbps can be set at Full duplex as well

filter or to forward the packet. Packets whose source and destination addresses are on the same

network from processing them. A packet whose destination address is on another port segment

speed, and the device at the other end of the cable should similarly advertise / respond. Then

both sides will agree to the speed to be used. Depending upon the device connected, this will

the port has auto-negotiated for 10Mbps operation. (If a DS50 / DS60 port is connected to a

A Magnum DS60 Dual-speed Hub Plus provides switched connectivity at Ethernet

100Mbps for the switched copper port can be done through the manual switch underneath the

The first five RJ-45 ports independently support auto-negotiation for shared

10BASE-T and 100BASE-TX modes. Operation is according to the IEEE 802.3u standard.

auto-negotiation takes place. The DS50 / DS60 advertises it’s capability for 10 or 100Mbps

operation. Since Magnum DS50 / DS60 are hubs, they always operate in the shared or half-

longer distance. All ports can communicate to all other ports in a Magnum DS60, but local

be done at installation or for maintenance. Full duplex and Auto-negotiation mode at 10 or

port segment will be filtered, constraining them to that one port and relieving the rest of the

When an RJ-45 cable connection is made and each time a LINK is enabled,

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

non-negotiating device, it will default to 10Mbps speed and half-duplex mode, per the

wire-speed for port #6. The Magnum DS60C supports 10/100Mbs for copper media to

traffic on port #6 will not consume any of the bandwidth on any other port.

4.3 Switching Functionality for port # 6 (DS60s Only)

result in agreement to operate at either 10Mbps or 100Mbps speed.

4.2 Auto-negotiation and speed-sensing

duplex mode on first five (1-5) ports.

of switched port are described below.

Filtering and Forwarding

Page 33 of the GarrettCom DS60s user manual — 4.4 LEDs
Page 33 · click to enlarge
Page 33

COL 100 (port 1-5) : Collision, flashing when collision occurs on ports 1-5.

addresses, and 1MB dynamically allocated packet buffers, suitable for use in small and medium

one segment to another, the DS60’s switched port automatically keeps up with node locations.

COL 10 (port 1-5)Collision, flashing when collision occurs on ports 1-5

will be forwarded to the appropriate port, and will not be sent to the other ports where it is not

needed. Traffic needed for maintaining the operation of the network (such as occasional multi-

mode, which eliminates bad packets and enables peak performance to be achieved when there

The switched port at Magnum DS60 units have address table capacity of 8K node

size networks. They are self-learning, so that as nodes are added or removed or moved from

An address-aging algorithm causes least-used addresses to fall out in favor of new

The Magnum DS60’s switched port operates in the store-and-forward switching

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

frequently-used addresses. To reset the address buffer, cycle power down-and-up.

LK/RX (port 1-5)Steady ON when twisted pair link is operational,

Activity , flashing when port is receiving data.

“FF-A” Switch

FF A

4.5 (FF-A) Manual Switch, Port 6 for DS60C

100 (port 6) : Speed is at 100Mbps .

FDX (port 6) : Port is at Full-Duplex.

PWR : Steady ON when power applied.

at 100Mbps.

at 10Mbps.

underneath Port 6 on the right front panel of

allows users to configure Port 6 as either a

The FF-A slide switch

Full fixed at 10/100 port or act as an Auto-

the Magnum DS60C. See figure 2.2.3 for

location of the switch relative to Port 6.

cast packets) is forwarded to all ports.

negotiation Ethernet port. It is located

is heavy traffic on the network.

4.4 LEDs

Address Learning

Page 34 of the GarrettCom DS60s user manual — 4.7 Up-link Switch, Port 1
Page 34 · click to enlarge
Page 34

that the unit be powered down and back up to reset the internal buffers of the switch. Even

though it is not always required, powering down and up will enable proper packet handling

Set the slide switch to the left “=” position Figure 4.4: Up-link Switch

for twisted pair cable segments from the DS50 & DS60C port to a user device. Set the slide

After switching from Full fixed to auto-negotiation or vice versa, it is necessary

The F and H switch enable this Dual-speed Hub plus to easily connected to any

switch is located to the left of port 1.

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

other Fiber Switch or Hub. The Full-Duplex 100Mbps fiber port supports a much longer

switch to the right “X” position for cascaded or up-link segment connections from the

DS50 & DS60C port 1 to another repeater or hub in the network. Verify proper switch

position by noting the port’s LINK LED status, which illuminates when proper link is

“F-H” Switch

UP-LINK

F H

distance then the 100Mbps Half Duplex in any fast Ethernet network.

up-link slide switch for port 1. This allows repeater-to-repeater

The Magnum DS50 & DS60C is equipped with one

connections without a special cross-over cable. The up-link

4.6 (F-H) Manual Switch, Port 6 for DS60F

provided underneath the Switched fiber port#6, allow the

user to set the fiber port at 100Mbps Full duplex or

in all cases for both segments of the network.

4.7 Up-link Switch, Port 1

100Mbps Half-duplex.

established.

The manual switch

Page 35 of the GarrettCom DS60s user manual — 5.0 TROUBLESHOOTING
Page 35 · click to enlarge
Page 35
4. If the problem is isolated to a network device other than the Magnum DS50 / DS60, it
1. If difficulty is encountered when installing or operating the Magnum DS50 / DS60,

Make sure that the AC power cord is properly plugged into the DS50 / DS60 unit.

5. If the problem continues after completing Step 4 above, contact your supplier of the

Magnum DS50 / DS60 unit (or if unknown, contact GarrettCom) by fax or by phone

Should problems develop during installation or operation, this section should help

refer back to Section 3.0, Installation and Section 4.0, Operation. Check to make

impaired during installation. (About 90% of network downtime can be attributed

consistently high performance in all network environments. Both the installation and

operation of a Magnum DS50 / DS60 Dual-speed Hub Plus are simple procedures (see

below prior to contacting your supplier. However, if you are unsure of any procedure

described in this section, or if the Magnum DS50 / DS60 is not operating as expected,

do not attempt to repair or alter the unit. Contact your supplier (or if unknown, contact

3. Be certain that the AC power cord is plugged into a functioning electrical outlet.

is recommended that the problem device be replaced with a known good device.

Verify whether or not the problem is corrected. If not go to Step 5 below. If the

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

Section 3.0, INSTALLATION); operation is very simple and is described in Section

to locate, identify and correct such problems. Please follow the suggestions listed

problem is corrected, the Magnum DS50 / DS60 and its associated cables are

2. Check the cables and connectors to ensure that they have been properly

All Magnum Ethernet products are designed to provide reliability and

connected and the cables/wires have not been crimped or in some way

sure that the various other components of the network are operable.

Use the PWR LED to verify that the unit is receiving proper power.

5.1 Before Calling for Assistance

to wiring and connector problems.)

5.0 TROUBLESHOOTING

GarrettCom) for assistance.

functioning properly.

for assistance.

Page 36 of the GarrettCom DS60s user manual — 5.2 When Calling for Assistance
Page 36 · click to enlarge
Page 36
2. An accurate list of GarrettCom product model(s)involved, with serial number(s).
4. A record of changes that have been made to your network configuration prior to

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form. Please

the occurrence of the problem. Any changes to system administration procedures

products that are under warranty at no charge, and will return the warranty-repaired units to

3. It is useful to include other network equipment models and related hardware,

All returns for repair must be accompanied by a Return Material Authorization

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

d. Any particular application that, when used, appears to create the problem;

including personal computers, workstations, terminals and printers; plus, the

GarrettCom will carefully test and evaluate all returned products, will repair

the sender with shipping charges prepaid (see Warranty Information, Appendix A, for

complete details). However, if the problem or condition causing the return cannot be

Include the date(s) that you purchased the products from your supplier.

1. A complete description of the problem, including the following points:

Failure symptoms, including a full description of the problem.

5.3 Return Material Authorization (RMA) Procedure

(RMA) number. To obtain an RMA number, please use this URL -

Please be prepared to provide the following information.

various network media types being used.

Name and phone number of your contact person.

Packing List Number (or Sales Order Number)

duplicated by GarrettCom, the unit will be returned as:

c. The components involved in the problem;

a. The nature and duration of the problem;

b. Situations when the problem occurs;

have the following information readily available:

Name of your company / institution

Serial Number (or Invoice Number)

5.2 When Calling for Assistance

should all be noted in this record.

No Problem Found.

Your shipping address · Date of installation · Product name

Page 37 of the GarrettCom DS60s user manual — APPENDIX A: WARRANTY INFORMATION
Page 37 · click to enlarge
Page 37
1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for

Should you need to ship the unit back to GarrettCom, please follow these instructions:

shipping protection. ( You may retain all connectors and this Installation Guide.)

2. Clearly mark the Return Material Authorization (RMA) number on the outside

workmanship for a period of three (3) years from the date of shipment by GarrettCom.

This warranty will not be effective if, in the opinion of GarrettCom, the product

GarrettCom reserves the right to make a charge for handling and inspecting any

Please complete the warranty card as this acts as a product registration, and mail

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

under warranty. Testing and repair of product that is not under warranty will result in a

GarrettCom, Inc. warrants its products to be free from defects in materials and

components in the products that prove to be defective at no charge other than shipping

has been damaged by misuse, misapplication, or as a result of service or modification

GarrettCom reserves the right to charge for the testing of non-defective units

During this warranty period, GarrettCom will repair or, at its option, replace

This material may cause electro-static shock damage to the unit.

and handling, provided that the product is returned pre-paid to GarrettCom.

3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to:

product returned for warranty repair which turns out not to be faulty.

APPENDIX A: WARRANTY INFORMATION

5.4 Shipping and Packaging Information

it to GarrettCom within two weeks of your purchase.

Attn.: Customer Service

47823 Westinghouse Dr. Fremont, CA 94539

GarrettCom, Inc.

of the shipping container.

other than by GarrettCom.

customer (user) charge.

Page 38 of the GarrettCom DS60s user manual — A+
Page 38 · click to enlarge
Page 38

B1.0 SPECIFICATIONS - FOR MAGNUM DS50 / DS60 DUAL-SPEED HUBS PLUS

configuration provides an Ethernet networking solution utilizing a special power supply in hubs

The –48VDC solution is particularly useful in the telecommunication industry, where

With the exception of the power supply, all specifications and functions of Magnum DS50

Magnum DS50 / DS60 are easily installed in a variety of applications where 24VDC

broadcasters, publishers, newspaper operations, brokerage firms and other facilities often use a

the two inputs. It protects the hub from incorrect DC input connections. An incorrect polarity

it is common for facilities to operate on -48VDC power. Such companies include regular and

The 24VDC solution is particularly useful in the Industrial environment, where it is

common for facilities to operate on 24VDC power. The 24VDC application is mainly used in

B2.0 24VDC or -48VDC POWER OPTION, THEORY OF OPERATION The 24VDC or -48VDC power option is designed using diodes inside on each DC

communication companies. In addition, many high availability equipment services, such as

Power Consumption: Model DS50 / DS60: 6 watts typical, 10 watts max.

GND GND CHASSIS

or -48VDC power is used as the primary power source. The –48VDC and 24VDC power

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

SUPPLY

FUSE +

/ DS60 24VDC or -48VDC models are identical to those listed in the main manual.

HUB

connection, for example, will neither affect the Dual-speed Hubs, nor its power supply

battery backup system to maintain operations in the event of a power failure. It is also

the Industrial environment, such as chemical plants, paper mill, stone quarrying plant,

frequently used for computer system backup, management and operations monitoring

wireless telephone service providers, Internet Service Providers (ISPs) and other

B3.0 APPLICATIONS FOR DC POWERED ETHERNET HUBS

APPENDIX BOptional 24VDC or -48VDC Power Supply

Power Consumption: Model DS50 / DS60: 5 watts max.

DC Power Connector: 3 terminals: ( -) , “GND”, (+)

DC Power Connector: 3 terminals: ( -) , “GND”, (+)

internally, nor will it blow the fuse in the internal power supply.

A+

A-

Input Voltage-36 to -72 VDC
Input Voltage20 to 36 VDC

power connection terminals, so that the power

from an external source can only flow into the

hub. This allows the DS50/60 to operate only

Power Supply (Internal -48VDC Option)

Power Supply (Internal 24VDC Option)

whenever DC power is correctly applied to

power input line behind the two external

wastewater treatment Plant etc.

with a proven track record.

equipment.

Page 39 of the GarrettCom DS60s user manual — B5.0 OPERATION
Page 39 · click to enlarge
Page 39

The actual connection procedure is very straightforward. Simply connect the leads to

1. Minimum 14 AWG cable for connection to a Centralized DC power source. 2. Fastening torque of the lugs on the terminal block: 9 inch pound max. 3. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches

In this picture, the 24VDC or -48VDC terminal block on the Magnum DS50 / DS60

lead which is more “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply

Operation of the Magnum DS50 / DS60 with the optional 24VDC or -48VDC power

Figure B4.1Optional Terminal Block on Magnum DS50 / DS60 with -48VDC power

ground, so the user may elect to Ground either + or = terminal to suit the customer’s use.

Before connecting hot lines to the Terminal Block of –48VDC or 24VDC, always

use a digital voltmeter to measure the output voltage of the power supply and determine the

is located on the rear of the unit and is equipped with three (3) screw-down lead posts. The

To order the optional -48VDC power supply factory installed, add a suffix of “--

48VDC” after the product’s standard model #. Example: Magnum DS50-48VDC. Similarly, to order the optional 24VDC industrial specific power supply factory

Magnum DS50 / DS60s Dual Speed Hubs Installation and User Guide (06/02)

An optional ON-OFF manual switch, available on some Magnum units, is not

the Magnum unit, beginning with ground. Ensure that each lead is securely tightened.

_ + GND

leads are identified as negative (-), positive (+), and chassis ground (GND).

installed, add a suffix of “ 24VDC” after the product ‘s standard model #.

included on the Magnum DS50 / DS60 Dual-speed Hubs Plus.

supply is identical to that of the standard AC-powered models.

Please refer to Section 6.0 for troubleshooting

must be connected to the post labeled “+”.

B6.0 ORDERING INFORMATION

installation of the 24VDC or -48VDC

power source leads to the 24VDC or -

48VDC power terminal block on the

Example: Magnum DS60- 24VDC.

This section describes the

Magnum DS50 / DS60. (see figure

B7.0 TROUBLESHOOTING

of the terminal block.

B4.0 INSTALLATION

B4.1 UL Requirements

B5.0 OPERATION

right).

-36 to -70VDC

Ask about the GarrettCom DS60s

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom DS60s

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom DS60s manual PDF

39 pages·553 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…