10 / 100 Dual-Speed Stackable Hubs
Magnum DS 880

a
a
s
t

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a
contains no user serviceable parts. Attempted service by unauthorized
experienced with Magnum DS880 10/100 Dual Speed Stackable Hubs
personnel shall render all warranties null and void. If problems are
of this publication may be reproduced without prior written permission from
products, consult Section 5, Troubleshooting, of this User Guide.
Copyright © 2001 GarrettCom, Inc. All rights reserved. No part
10/100 Dual-Speed Stackable Hubs
UL is a registered trademark of Underwriters Laboratories
NEBS is a trademark of Telcordia Technologies
Ethernet is a trademark of Xerox Corporation
registered trademark of GarrettCom, Inc.
Printed in the United States of America.
GarrettCom, Inc.
Trademarks

This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to take whatever
Please use the mailing address, phone and fax numbers and email address listed below:
Radio Frequency Interference Statement
email support@garrettcom.com
GarrettCom, Inc.
47823 Westinghouse Dr. Fremont, CA 9453-7437
measures may be required to correct the interference.
Federal Communications Commission · Fax (510) 438-9072 · Contacting GarrettCom, Inc

Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports,
GarrettCom, Inc.offers the premium-quality Magnum™ line of Ethernet LAN
connectivity products with industry-standard functionality and built-in fiber
configurability. Magnum products are designed for use in demanding Carrier Class,
4K-Series Switches, 100 & 10Mbps, copper ports with optional fiber port, with auto-negotiating full switching performance
“Outdoor” Ethernet Switch, for temperature uncontrolled locations
8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series
Industrial Grade and OEM applications where reliability is a primary consideration.
6 10/100 and 2 100Mb fiber ports, can be connected in strings Mixed-Media Fiber Hub, 16-port Stackable, 10/100 auto-sensing
10Mb series and 100Mb series, both w/ optional port modules Personal Switches, 10/100Mb
All media combinations, incl. fiber ST, SC, mm., single mode
Bridge Port Modules (BPMs), 4 types, for segment isolation
2, 4 and 8 Port Models Transceivers, 10Mb and 100Mb series 10Mb Mini-Transceivers
Repeater Port Modules (RPMs), 6 types for Ethernet media
mixed-speed and mixed-media types, full switching performance
Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing
Stackable Concentrators, SNMP optional, 13-Ports
8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb
Mini-Concentrators, 7 Ports, Repeaters, 2-Ports
and Coax Models, All Types - Apr, 01
8-port, with two switched ports (1 fiber built in) Personal Hubs, 10Mb series
The Magnum Line
OVERVIEW
Stackable Hubs, SNMP Optional
Fan-Outs, 10Mb series


100 or 10 Mb/s per port, auto-sensing for speed. DS880 hubs support two traffic domains, one at 100Mb/s and one at 10Mb/s, have eight RJ-45
Filtering and Forwarding Rate from 100Mb ports: 148,800 pps max
Filtering and Forwarding Rate from 10Mb ports: 14,880 pps max.
10BASE-T (Unshielded twisted pair) - 100 m (328 ft)
ports, and are stackable up to 3 units high operating as one repeater.
100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
Ambient Temperature: 32ºF to 122ºF (0ºC to 50ºC) Storage Temperature: -20ºC to 60ºC
100Mb: Ethernet IEEE 802.3u , 100BASE-TX 10Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3u
Maximum Ethernet Segment (or Domain) Lengths
When a port is operating at 100Mb/s:
When a port is operating at 10Mb/s:
Power Consumption : 20 watts max.
1.1 Technical Specifications
1.0 SPECIFICATIONS
Operating Environment · Network Standards · Performance

A stacking cable with 50-pin “SCSI” male connectors, shielded, 9 inches (23 cm)
On/Off connection to a central hub or another cascaded hub. The up-link port #8
regular (=position) user segment port to a crossover (X position) up-link port for
is auto-sensing for speed, and the up-link works the same at 10Mb or 100Mb.
(Model DS880-B), Off when no bridge module is inside (DS880-A)
100 (per port): Steady On when speed is 100Mbps , Off when speed is 10Mb, flashing when auto-negotiating or when not connected (no LINK)
Network Cable Connectors - for the eight RJ-45 shielded female ports per hub
long, is included with each Magnum DS880-A Dual-Speed add-on unit.
Dimensions: 9.75 in D x 8.5 in. W x 1.4 in. H ( 25cm x 22cm x 3.5cm)
Suitable for wiring closet shelf, wall or desktop mounting.
Enclosure: High strength metal. Metal mounting brackets included.
Three years, return to factory Made in USA
Stacking Cable - stacking may be up to four DS880 hubs, or 32 ports
48VDC Power Supply (Optional) Power Input Voltage : 36 to 72 VDC (auto ranging)
Power Consumption: 20 watts max.
UL Listed (UL 1950), cUL, CE
(1.1 Technical Specifications, continued)

domains. Stacks up to three DS880-A units. One DS880-B unit per
ports, each auto-sensing for 100Mb or 10Mb operation. Stackable
up to three units high, with all ports in one stack operating as two
separate traffic domains, one domain at 100Mb/s and one domain
supply, cooling fan, and metal brackets for shelf or wall mounting.
selectively forwarding packets between the 100Mb and the 10Mb
at 10Mb/s. Includes stacking cable, internal auto-ranging power-
switch module that bridges the two traffic domains, filtering and
stack supports all ports at 100Mb or 10Mb communicating with
each other. The internal switch has 2Mb dynamic store-and-
forward packet buffers and 8K node addresses.
GarrettCom reserves the right to change specifications, performance
characteristics and/or model offerings without notice.
1.2 Ordering Information

Remove the Magnum DS880 Dual-Speed Hub from the shipping container. Be sure to
In the event there are items missing or damaged contact your supplier. If you need to
Examine the shipping container for obvious damage prior to installing this product;
Inspect the contents of this package for any signs of damage and ensure that the items listed
keep the shipping container should you need to ship the unit at a later date. To validate the
return the unit use the original shipping container. Refer to Chapter 5, Troubleshooting, for
notify the carrier of any damage which you believe occurred during shipment or delivery.
product warranty please complete and return the enclosed Product Registration Card to
1 Stacking Cable, Model DS880-A add-on (no bridge inside) units only
1 AC Power Cord (U.S. and other 115 vac locations only)
1 Magnum DS880-A or DS880-B Dual-Speed Hub Unit
1 Set of metal clips and screws for wall-mounting
2.1 Inspecting the Package and Product
1 Installation and User Guide
1 Product Registration Card
GarrettCom, Inc. as soon as possible.
This package should contain:
specific return procedures.
below are included.

module which interconnects the 10 Mb and the 100Mb traffic domains. This enables all users on
100Mb domains, maintaining peak performance in each domain unaffected by local traffic in the
sensing. Each port can independently identify (via IEEE 802.3u auto-sensing) and accept either
one for the 10Mb traffic. The 100Mb users share the 100Mb domain’s bandwidth and the 10Mb
also change from one traffic domain to the other at any time without affecting the speed of other
a DS880-B hub or a DS880 stack, whether 100Mb or 10Mb, to talk to each other. The internal
other domain. The internal bridge is self-learning, with large address table capacity for up to 8K
node addresses. As networked nodes are added or removed or move from one speed domain to
There are two internal traffic domains in Magnum DS880 hubs, one for the 100Mb traffic and
Any DS880 port can connect into either the 100 or the 10Mb traffic domain, and can
ports. The automatic per-port speed-sensing is continuous, allowing the connected devices to
100Mb ports, up to the maximum of 32 ports (4 units) in one stack, can be in use at any time.
100Mb or 10Mb Ethernet signals, adapting to match the best speed of the connected device.
automatically expand to support all of the ports in the stack. Any combination of 10Mb and
change speed at any time without impairing the operation of the other ports and connected
As Magnum DS880 Dual-Speed units are stacked, the two shared traffic domains
One DS880 Model, the Magnum DS880-B, includes an internal bridge or switch
Magnum DS880 Dual-Speed hubs have eight RJ-45 ports, each 10/100Mb auto-
switch of the DS880-B filters and selectively forwards packets between the 10Mb and the
BR UPLINK 1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
the other, the DS880’s internal switch automatically keeps track.
RX
PWR
ACT
COL
users share the 10Mb domain’s bandwidth.
2.2 Product Description - General
10Mb Hub 100Mb Hub
9 10 11 12
PWR 1 2 3 4 5 6 7 8 Magnum
PWR 1 2 3 4 5 6 7 8 9 1 0 11 12
devices.
8000E Stackable · Hub

DS880-A “add-on” hubs . . . units that do not have the bridge module inside, and which cost less
(such as the Magnum 300ES Two-Port Switch) available to interconnect the two speed domains,
or 100Mb network. DS880s are suitable for wiring closet shelf, table-top or vertical mounting.
DS880-A units can also be used without a DS880-B, whereupon they will function as
dual-speed stackable hubs. This could be desired if there is an external non-auto-sensing switch
Each DS880 has its own internal power supply, and is easily added to an existing 10
Only one DS880-B unit is needed to support a stack. Additional 8-port units of the
or if only 100Mb devices are connected and the 10Mb domain is unused (or vice-versa), or if
accordingly . . . can be added to the stack, up to the 4-unit stack maximum. In a stack, the
dual-speed operation with two unconnected and uncoordinated domains is needed for the

BR UPLINK 1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
DS880A DS880B Bridge Module
DS880-B unit (illustrated below as the bottom unit) can be in any stack position.
RX
PWR
ACT
COL
1 2 3 4 5 6 7 8 UPLINK
100 UPLINK 1 2 3 4 5 6 7 8
2.2 Product Description - General (continued)
BR UPLINK 1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
A
A
B
application.
LK
RX
ACT
COL

operation on that DS880 port will be at 10Mb/s. Of course, the hubs’ auto-negotiation technique
sensed by the DS880 hub will be indicated by the ‘100’ LED for that port. The ‘100’ LED is ON
has eight RJ-45 twisted-pair ports and one cascading (UP-LINK) switch for Port 8 on the right.
connected, the ‘100’ LED corresponding to that port will be blinking to indicate that it is trying
The Magnum DS880 chassis houses one main PC board, a bridge module daughter-
board in the Model DS880-B, and an internal power supply unit. The front side of the chassis
LEDs to indicate operating status are on the left front side. There are power (PWR)
set unto a “square” arrangement, for visual indication of the operating status of each domain.
And there are link (LK), receive (RX) and speed (100) indicators for each port. (See Section
1.1 “Specifications” for a technical description of the LEDs). The unit has a cooling fan on the
rear of the chassis. The internal power supply is auto-ranging for any AC power input of 115 -
All eight RJ-45 twisted pair ports support auto-sensing for speed, independent of the
indicates that it is capable of 100Mb speed, then operation on that port will be at 100Mb/s. If
bottom left corner which sends warm air out away from the unit to the rear. Stacking cables
The AC power cord connector, a universal recessed-male IEC type, is in the left
the connected device does not positively indicate that it is capable of 100Mb speed, then the
When a port is connected and LINK is present, the speed on that port that has been
other ports. Speed-sensing is performed by the DS880’s electronics in accordance with the
standards of the IEEE 802.3u auto-negotiation standard. If the connected device or node
when 100Mb speed is sensed, and is OFF when 10Mb speed is in use. When a port is not
is only for 10 / 100 speed, and does not provide for any full-duplex operation.
10Mb and 100Mb domains, Magnum DS880 Dual-Speed Hub
100 UPLINK 1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
230 vac, 50 - 60 Hz. (An internal DC power supply is optional).
to auto-negotiate. (See section 4.3 for operation of the LED’s).
connect in the rear (see Section 2.3 for stacking information).
2.2.2 10 / 100 Speed Auto-sensing
2.2.1 Magnum DS880 Chassis
RX
PWR
BR
ACT
COL
indicators for each of the
There are activity (ACT)
indicators for the unit.
and bridge-inside (BR) · and collision (COL)

units (no bridge inside) from the outside. The “BR” LED on the front will light up when power
proper operation of up to four DS880 units in a stack, and longer cables or unshielded cables are
convenient when locating the DS880s in a rack, for example, as two DS880s will fit side-by-side
connectors until they snap in firmly. Also, leave space in the left-rear area for the exhaust of the
is applied to indicate that a DS880 is a -B (bridge inside) model. (The “BR” LED will be off if
that two DS880-B units may be cascaded to operate together, however). Use DS880-B models
The DS880-B models with the bridge module inside look the same as the DS880-A
internal bridges would not be able to function properly when more than one is present. (Note
repeater with up to 32 dual-speed ports. Normally, one Magnum DS880-B hub per stack is
un-stacked, or with only 1 Model DS880-B in a DS880 stack. See Section 2.7, Example 3.
stacking port from one DS880 unit to the “In” stacking port of the other. Push in the cable
Up to four Magnum DS880s can be stacked to operate as one 10/100 dual-speed
the unit is a Model DS880-A). The DS880-B models cannot be stacked together, as their
When stacking DS880’s, please make sure to use only the shielded 9-inch long
stacking cable provided with each DS880-A unit. The cable length is designed to provide
When connecting DS880s in a stack, use the stacking cable to connect the “Out”
The 9-inch length is enough to provide for side-by-side stacking. This can be
not permitted as they will not operate properly at 100Mb speeds.
internal cooling fan in each DS880 unit. See Figure 2.3 above.
OUT IN
OUT IN
OUT IN
on a tray in a standard 19” rack space.
2.3 Stacking Magnum DS880s
between the two separate
100Mb and 10Mb traffic
www rrettCom com. .
domains in the stack.
needed to provide a
which cost less.

The DS880-B’s bridge module is implemented as a daughter board. DS880 units have
Magnum DS880-B’s contain a factory-installed bridge module to interconnect the two
traffic domains, filtering and selectively forwarding packets to allow only necessary packets to
domain, whether 100Mb or 10Mb, to talk to each other, and it keeps local traffic on one domain
The bridge operates in the store-and-forward mode, which filters out bad packets and
10Mb and of 100Mb packets is maintained correctly even when users move their connection, or
The unit has an up-link switch for Port # 8, located on the right-front side of the hub.
ports, Port # 8 is a dual-speed port which will sense the speed of the connected device. The up-
link switch operates the same, whether Port # 8 is connected to either 100Mb or 10Mb devices.
When the up-link port is used to cascade two DS880 hubs or stacks together, the auto-
suitable for use in large networks. Addresses are self-learning so that filtering / forwarding of
maintains optimum performance in both domains. Packet forwarding delay is only 5µs (plus
an LED on the front labeled ‘BR’ that will be ‘ON’ when the module is installed internally.
It enables the port’s cable to either connect to a user station ( = position) or to be cascaded to
DS880s to maintain high network performance. The bridge has 8K node address capacity,
another hub (X position). (See Section 4.4 for more details about up-link). Like all DS880
cross between the domains. This enables all of the users and nodes connected into either
packet time), much less than traditional store-and-forward bridge products, enabling the
allowed per repeater stack. Thus, if the DS880s in a stack have more than one
Power any DS880 unit on and if the BR LED is ON, it is a Magnum DS880-B unit.
sensing feature will cause the connecting link to operate at 100Mb speed.
2.4 Bridge Module between the 10Mb and 100Mb Domains
BR (bridge) LED ‘ON’, it is an illegal configuration.
from consuming any of the bandwidth of the other domain.
2.5 Up-link Switch on Port 8 for Cascading
change speed, or power down.
DS880-B with bridge · module installed

Magnum DS880 Dual-Speed 10 / 100 hubs combine two logical hubs . . . one at 10Mb
Model DS880-B has an internal switch for filtering / forwarding traffic between the 10
Magnum DS880s can be stacked up to four units high for 32 ports, each 10 / 100 dual
speed. As additional units are added in a stack, the 10 and 100Mb traffic domains are
affecting operations. The switch in the DS880-B will not affect any standard software
The compact packaging of Magnum DS880s allows them to be installed in offices and
and one at 100Mb . . . in one physical box supporting two traffic domains. Each port
time, adapting automatically to any changes in the connected device’s speed. Speed-
An internal switch connects the 10 and 100Mb domains on Model DS880-B
traffic on the other domain. One DS880-B per stack supports switching for all ports.
The Magnum DS880-B operates as a hardware switch, only forwarding those packets
self-learning, enabling users to change port connections or 10 / 100 domains without
labs, or virtually any location within reach of a standard AC wall outlet. They comes
auto-ranging power supply for use worldwide. (Models with a 48vdc internal power
sensing is continuous. Individual ports can change to 100Mb or 10Mb speed at any
sensing complies with IEEE 802.3u, providing interoperability with other products.
performance switching provides full bandwidth in each domain, unaffected by local
from each domain that are needed on the other domain. Internal address tables are
in a durable metal enclosure for table-top or wall-mounting. They have an internal
Supports 10 or 100Mb network connections on each of eight RJ-45 ports
All ports support 10/100 auto-negotiation for speed, operating separately on each
port. Any mix of 10Mb and 100Mb users can be connected to the ports. Speed-
and 100Mb domains, allowing all connected devices to talk to each other. High
Installation is “Plug and Play”, Operation is Transparent to Software
expanded automatically to support the new ports at either 10 or 100Mb speed.
can operate at either 10 or 100Mb, independently of the other ports.
Auto-sensing for speed, 10 or 100Mb on each port
applications or SNMP network management platforms.
Small Enclosure Enables Use in Offices and Labs
Stackable for flexible expansion
supply are optionally available).
2.6 Features and Benefits

existing 10Mb network without having to change it. Nodes that are capable of 100Mb speed can
accommodating existing high performance users. The 100Mb traffic does not use the bandwidth
users operate at 100Mb, and some users and utility devices (such as print servers) run at 10Mb.

be moved to any DS880 dual-speed port, and will automatically operate at the higher speed.
All share the same hub, and talk to each other via the bridge module inside. Any node can
any port of the DS880-B. This allows simple plug-and-play addition of 100Mb ports to an
change speed at any time without affecting network operation or impacting other users.
The dual-speed ports on the DS880-B can be used for adding 100Mb users or for
of the 10Mb domain, so overall performance of the network is improved.
1 2 3 4 5 6 7 8 9 10 11 12
BR U PLIN K 1 2 3 4 5 6 7 8 100
1 2 3 4 5 6 7 8
BR UPLINK 1 2 3 4 5 6 7 8 100
R X
PW R
A CT
C OL
2.7 Applications
DS880-B adds a new
Figure 2.7.2 :

The stacking cables connect the DS880 units and carry the signals for both the 100Mb
all 100Mb ports are similarly together on a separate 100Mb traffic domain. When one DS880-B
A Magnum DS880 stack operates as one dual-speed repeater. A dual-speed repeater is
PDVs, cable types, cable distances, etc.) and can be treated as one 100Mb repeater. Both traffic
forwarding 10Mb and 100Mb packets between the two domains. This keeps the traffic between
and the 10Mb domains. In a stack, all 10Mb ports are together in a 10Mb traffic domain while
unit with a bridge inside is present in a stack, its bridge will support all of the ports in the stack
both a 10Mb hub and a 100Mb hub at the same time. This means that the 10Mb traffic domain
When expanding an Ethernet or Fast Ethernet installation, the Magnum DS880 Hubs
For additional expansion, DS880s can be expanded by stacking DS880-A “add-on”
distances, etc.) and can be treated as one 10Mb repeater accordingly. Separately, the 100Mb

DS880-B performing bridge-isolation of one domain from the other, filtering and selectively
units. The additional stacked ports are all auto-sensing dual-speed, and can be used at either
are ideally suited for connecting servers and stations that have (or may have in the future ! )
traffic domain obeys all of the rules of 100Mb Fast Ethernet shared networks (hop counts,
mixed speeds. Each traffic domain or segment has its own local traffic with the Magnum
obeys all of the rules of 10Mb shared Ethernet networks (hop counts, cable types, cable
the domains to a minimum and provides peak performance on both domains.
domains function within the same physical DS880 hub or stack of hubs.
and enable network traffic to move between the two stacked domains.
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 UPLINK
UPLINK 1 2 3 4 5 6 7 8
10Mb or 100Mb on a per-port basis.
Figure 2.7.3 :
Example 3 :

network devices need to be connected to communicate with each other. The compact size of the
wall-mounted (see instructions in 3.1.2 below). Wall-mounting brackets are included, usable for
1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment must be
3.) If the equipment is mounted in an enclosed or multiple rack system placement of the equipment must not overload or load unevenly
6.) If the intra-building wiring (cabling) is involved with this product(NEBS), then it is recommended to have shielded cable and the
unit allows it to be conveniently placed in an office or lab area, and it can also be either shelf of
single units (but not for stacks). The width of two DS880 units will fit in a 19” rack when they
accidental damage in a lab or workplace setting. Maintain an open view of the front to visually
monitor the status LEDs. Keep an open area around the unit so that cooling can occur from the
5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised
finished surfaces. When stacked, the rubber feet also provide separation between units for the
2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate air flow must be maintained for proper and safe
layout of the network. Typically the hub is placed where combinations of 10Mb and 100Mb
Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum
The Magnum DS880 Dual-Speed Hub can be easily mounted on a table-top or any
Before installing the equipment, it is necessary to take the
The location of a Magnum DS880 Dual-Speed Hub is dependent on the physical
suitable horizontal surface, and has four rubber feet to provide stability without scratching
4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent
DS880 site. The rugged metal case of the Magnum DS880 will normally protect it from
This chapter provides instructions for installing the Magnum DS880 hubs
overloading of the building/s electrical circuits.
small fan in the bottom-rear while the unit is in operation.
3.1 Locating Magnum DS880 Dual-Speed Hubs
shield is grounded at both ends.
3.0 Magnum DS880 Installation
3.1.1 Table-Top or Shelf Mounting
less than or equal to 500C.
following precautions:
exhaust of the rear cooling fan.
the rack system.
earthing path.
operation.
are side-by-side.

attaches the bracket to the mounting surface. It is recommended that the brackets be attached to
100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used.
8, if the LINK LED is not illuminated, change the setting of the up-link switch. If this
Each Magnum DS880 Dual-Speed Hub is shipped with two metal mounting brackets
(and screws) to allow the unit to be mounted in nearly any desired orientation or position. The
brackets are attached to the metal hub case using one of the metal screws for each bracket and
attaching to the Magnum DS880 through the round hole of the bracket. A user-supplied screw
The Magnum DS880 Dual-Speed Stackable Hubs can be connected to the following
In either case, the maximum distance for unshielded twisted pair cabling is 100 meters (328 ft).
100Mb) be used whenever possible in order to provide flexibility in a mixed-speed network, since dual-speed ports are auto-sensing for either 10 and 100Mb/s.
The following procedure describes how to connect a 10BASE-T or 100BASE-TX
does not help, ensure that the cable is connected properly and that the device on the
two opposite corners of the unit. When properly attached, the brackets will extend slightly
below the base of the unit to allow clearance for the rubber feet and the cooling fan exhaust.
3.2.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded)
twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and
Twisted Pair (CAT 3) 10BASE-T RJ-45
Twisted Pair (CAT 5) 100BASE-TX RJ-45
Media IEEE Standard Connector
unshielded or shielded cables and wiring may be used.
other end is powered and is not defective.
3.1.2 Wall (or Vertical Surface) Mounting
3.2 Connecting Ethernet Media
shielded twisted pair cables.

topology . . must be less than 512 BT (Bit Times). Bit Times are related to media type as shown
network devices which are connected by means of a repeater or repeaters such that no bridging
Each Fast Ethernet device component also has an associated BT delay which depends
To determine whether a prospective network topology adheres to the collision domain
The 100Mbps Collision Domain Diameter is the length of the longest path between
devices are present between any two devices in the cluster. In order to install an IEEE 802.3u
component and the associated BT delay. A “DTE” is an end node, such as a user station. Note
diameter specification, the following formula should be applied to the worst case path through
3.2.2 100Mbps Collision Domain Diameter, Cable Distances and PDV Calculations
the network. The worst case path is the path between the two Fast Ethernet devices (DTEs)
any two devices in a single collision domain. A collision domain is defined as a cluster of
Fiber Optic 1.000 Shielded TP cable 1.112 Category 5 Cable 1.112 Category 3, 4 Cable 1.140 *Worst case delays taken from IEEE Std 802.3u-1995, actual delays may be less for a particular cable. Contact your cable supplier for exact cable specifications.
on the physical signaling system employed. Table 3.2.2b shows each Fast Ethernet device
compliant Fast Ethernet network, the collision domain . . regardless of the actual network
Component Round-trip delay in Bit Times (BT)
**Note, the delay is only 80 Bit Times for the DS880, front-port-to-front-port.
Media Type Round-trip delay in
that there is only one DTE pair associated with any device-to-device path.
Bit Time per Meter (BT/m)
2 TX DTEs 100 2 FX DTEs 100 1 FX and 1 TX DTE 100 1 T4 and 1 TX or FX DTE 127 Class I Repeater 140 Class II Repeater with any
*Worst case delays taken from IEEE Std 802.3u -1995.
combination of TX and FX ports
which have the longest round-trip time.
in Table 3.2.2a.
92 **

segments (i.e. from computer to hub) and needs to know how long the inter-repeater Category 5
IEEE standard, this value must be less than 512 BT. The safety margin is specified in BT and
may be a value between 0 and 5. This margin can be used to accommodate unexpected delays
3.2.2a. Here, an integrator wishes to cascade the 100Mbps collision domains of two Magnum

may be used to cascade the Magnum DS880s. Note that this inter-repeater cable length may be
It is also possible to cascade a group of up to nine Magnum DS880s (serving up to 56
A typical example of a PDV calculation is shown below, and is illustrated in Figure
DS880 Hubs(each having a PDV of 80BT) for use with standard 100m Category 5 user cable
The resulting value tells us that a Category 5 cable with a length of up to 30 meters
users with full-length 75m cables to each) by using short inter-repeater cable segments. The
length. An illustration of this example is shown in Figure 3.2.2b, where the hub-to-user cable
PDV is the Path Delay Value of the worst case path. For the network to adhere to
cable segment, used to cascade the hubs, can be. The variable “X” represents the unknown
following is an example of how to calculate the maximum allowable cascade cable segment
⇒ 25 m maximum total length for Category 5 inter-repeater segment,
such as extra long patch cable. A safety margin of about 2 to 4 BT is recommended.
BR UPLINK 1 2 3 4 5 6 7 8
increased by shortening the lengths of the 100m hub-to-user cable segments.
PDV = X + ((111 + 111) + (80 + 80) + (100) + 2 ) BT < 512 BT
Twisted Pair cable length, TL < (28 BT) / (1.112 m/BT)
Cat. 5 cable for
(DTE pair delay) + (safety margin)
100 to u m Cat. 5 cables
BR UPLINK 1 2 7 8 3 4 5 6
512 > (X + 486) BT X < (512 - 486 ) BT, X < 28 BT
the BT delay for the TX DTE pair,
and a safety margin of 2 was used.
100m of Category 5 cable (1.112
BT/m* 100m), 80 is the BT delay
for each Magnum DS880, 100 is
maximum cascade cable delay.
TL < 25 meters
where 111 is the BT delay for
ser devices

bit time delay for each Magnum DS880 front-to-front ports, 100 is the BT delay for the TX DTE

Table 3.2.2c shows maximum cable lengths for common network configurations using
lengths are up to 100 meters for Cat 5 twisted pair. The variable “X”, the maximum hub-to-hub
the 100Mbps domain of the Magnum DS880 vs. the industry standard delay of 92 BT for Class
II repeaters. The installation flexibility and network growth potential is accordingly better with
In the above example, 80 is the BT delay for 75m of Category 5 cable (1.112 BT/m), 80 is the
due to the relatively shorter bit time (80 BT actually measured, for front-port-to-port) delay of
using measured PDV data supplied by the equipment manufacturer in important installations.
2 meter Cat. 5 cable for cascading All us
industry standard repeater PDV numbers. Calculations such as above should be performed
BR UPLINK 1 2 3 4 5 6 7 8
⇒ 2 meters (6 ft.) length max. for each of the cascade segments,
PDV = X + ((100) + (80 + 80 + 80 )+ (83 + 83) + 2 ) BT < 512 BT
pair in the user stations, and 2 BT is the safety margin applied.
512 > (X + 508) BT, X < 4 BT Twisted pair user cable length, TL < (4 BT) / (1.112 m/BT)
1 1 100.0 n.a. All ports TX
2 2 100.0 5.0 All ports TX
2 2 92.0 20.0 All ports TX
3+ 3 60.0 1.0 All ports TX
BR UPLINK 1 2 3 4 5 6 7 8
TL < 3.6 meters for two hub-to-hub cascading cables
Magnum DS880s than with hubs that merely meet the standard.
BR UPLINK 1 2 3 4 5 6 7 8
Max. Inter-
Hop Count Max. User
cable delay, is calculated as follows:
of multiple Magnum DS880 hubs
permit, and is different from what
competitive Class II hub products
cascading level and cable length is
cascaded Magnum DS880 hubs
normally allow. This additional
is a capability beyond what
ww GarrettC co. .

Interface Cards) which support Auto-Negotiation. The Magnum DS880 will establish link with
signaling system. When connecting a NIC to the DS880, it may be necessary to reload the NIC
has a recessed male IEC connector for the AC power cord in the rear. A six-foot 115 VAC 60Hz
Instructions for connecting the Magnum DS880 Dual-Speed Hubs to the various Fast
100BASE-TX (such as 10BASE-T). When 100Mb operation is agreed and in use, the 100Mb
Magnum DS880 Dual-Speed Hub incorporates an internal universal power supply, and
Each Magnum DS880’s auto-ranging power supply supports installation environments
any NIC which can send and receive the Fast Link Pulse (FLP) coding for the 100BASE-TX
where the AC voltage is from 90 to 260 volts with an input frequency between 47 and 63 Hz,
and consumes a maximum of 20 watts. In order to power down the unit, simply unplug either
The Magnum DS880 Dual-Speed Hub will function properly with NICs (Network
LINK/ACT LED is illuminated, steady ON if no traffic or blinking when there is traffic.
drivers on the user device if the NIC has been communicating with a protocol other than
power cord is supplied with each unit shipped within the United States and Canada.
3.2.3 Connections to NICs which support Auto-Negotiation
Ethernet media are given in the following sections.
3.3 Powering the Magnum DS880
end of the AC power cable.

The Magnum DS880-A handles the two different traffic domains separately (unless it
the Ethernet (10Mb/s) and Fast Ethernet (100Mb/s) domains. It joins the two network domains
utilization and performance. Magnum DS880s are hardware plug-and-play devices. There is no
packets, the filter and forward decisions are made based on the destination address contained in
each packet. If the destination address is on the same domain from which the packet originated,
domain. If it is a new node address coming in which the switch did not previously know about,
it “learns” the new address and puts it in the correct port address table. See “Address Learning”
is stacked with a DS880-B). The DS880-B provides switched (bridged) connectivity between
for unified operation, and filters/ forwards packets in both directions to maximize bandwidth
software set-up to be done at installation or for maintenance. The functions of the DS880s are
then it is filtered and not forwarded to the other domain. If the destination address is not found
Each time a packet is received on one domain of the bridge module, the decision is
to be a match in the address table for the originating domain, then it is forwarded to the other
taken to either to filter or forward the packet. Errored packets are always filtered. For good
This chapter describes the function and operation of the Magnum DS880 hubs.
in the 10Mb domain address table. 100Mb Domain : 100Mb packets are forwarded when the destination address is
NOT in the 100Mb domain address table.
in the 100Mb domain address table.
This diagram below shows the filter / forward logic for both domains.
10 Mb Traffic 10 BUS 100
4.1 Dual-Speed Functionality
described in this manual.
in the 10Mb domain address table.
for more details.

address table capacity of 8K addresses. With a large address table, a Magnum DS880 can serve
Magnum DS880-B will take in each packet-processing situation, and when a new node address
will be added to the internal Address Table. When a new node-address packet comes into a port
processed. The address tables are flushed periodically to update the network status and to purge
By selectively forwarding packets from each domain to the other domain based on its
users on both sides of the network. As shown in Figure 4.1, it keeps the local traffic on each side
the needs of a medium-sized to large network. Table 4.1 shows what filter / forward action the
contained, preventing unnecessary packets and bad packets from traveling to the other domain
The Magnum DS880-B bridge module is a state machine design which has a total
for the first time, then the new source address is “learned” at the same time that the packet is
4.1.1 The Magnum DS880-A and -B Dual-Speed Hubs need no software set-up and are
switching (bridging) logic, the Magnum DS880-B increases the available bandwidth for the
transparent to system and application software, including network management
forwarded. After learning, subsequent packets from the same node address are routinely
Packet Source Destination Address Table Filter/Forward
and using up bandwidth needlessly over there. This results in more available network
bandwidth on both sides and a throughput increase on for all users on both domains.
10 Mb Not in table Not in table Add source to table Forward
10 Mb In table Not in table None Forward
100 Mb Not in table Not in table Add source to table Forward
100 Mb In table Not in table None Forward
Source Address Address Maintenance Action
10 Mb Not in table In table Add source to table Filter
10 Mb In table In table None Filter
100 Mb Not in table In table Add source to table Filter
100 Mb In table In table None Filter
any inactive stations from the tables of both domains.
1.1 Software Transparency
software.


single port. To fix the speed at 100Mbps, both DIP-switch position have to slide towards the 100
The latest Magnum DS880 unit is equipped with Switches for setting Port Speed.
figure 4.2 above. These switches allow the user to set the speed at 10, 100Mbps or 10/100Mbps
The Switch SW3 represents port#1 to 4 and the switch SW2 port#5 to 8 as shown in the Fig 4.2
above. The switches has 8 Dip-switches each. Every two contiguous Dip-switches represent one
Figure 4.2a Speed settings at 10Mbps (OFF or 100) position as shown in the Fig 4.2a above.
The SW2 and SW3 switches are located on the right side of the main board as shown in the
port# 1,2,3 has been fixed at 10Mbps
4.2 Port Speed Settings for 10,100Mbps Or 10/100Mbps Mode only
auto-sense. The unit has been set at 10/100Mbps at the time of shipping.
100Mbps. Setting the port at 10Mbps is little bit tricky. The user has to slide the odd number
side. In the above Fig 4.2 the Switch SW3 has
of Dip-switch to ON (or 10/100) position and
been fixed 10/100Mbps and Switch SW2 at
even number to reverse

corresponding port is sending out auto-negotiation pluses out that port. When a connection is
advertised. Depending upon the device connected, it will either advertise at 10Mb or 100Mb
operation and is processing packets at 100Mb/s, When it is OFF, it is at 10Mb/s. If a DS880
port is connected to a non-negotiating device, it will default to 10Mb speed. Since Magnum
connection is established between the port and the attached device.
from the DS880 port to a repeater or hub. Verify proper switch position by noting the port’s
ON when a bridge module is present in the unit (model DS880-B)
receiving data from the attached device, i.e., there is activity on the
10BASE-T and 100BASE-TX modes. When the ‘100’ LED is flashing, it means that the
When the ‘100’ LED is steady ON, the port has auto-negotiated for 100Mb
Set the slide switch to the “=” position for twisted pair cabling from the DS880
port to a user device, or to the “X” position for cross-over or up-link segment connections
4.4 LED’s PWR : Illuminates GREEN to indicate AC power is applied to the unit.
Steady ON when the port speed is 100Mbp/s, OFF for 10Mbp/s
All eight RJ-45 ports independently support auto-negotiation for shared
DS880s are hubs, they always operate in the shared or half-duplex mode on all ports.
made, the other device should respond and both sides should agree to the speed being
OFF when no bridge module is present ( model DS880-A)
Blinks intermittently when a collision occurs.
LINK LED status, which is illuminated when a proper link is made.
The Magnum DS880s have one up-link slide switch,
without a special cross-over cable. It works the same for 10Mb
used with port 8. This allows repeater-to-repeater connections
speeds. Silence means the port defaults to 10Mb.
4.3 Auto-negotiation and speed-sensing
port.
4.5 Up-link Switch
or 100Mb connections.

below prior to contacting your supplier. However, if you are unsure of the procedures described
expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact
high performance in all network environments. The installation of the Magnum DS880 10/100
Dual Speed Stackable Hub is a straightforward procedure (see INSTALLATION, Section 2.6);
in this section or if the Magnum DS880 10/100 Dual Speed Stackable Hub is not performing as
Installation Section of the applicable chapter of this manual. Also check to make sure
the cables/wires have not been crimped or in some way impaired during installation.
Dual Speed Stackable Hub unit. Be certain that each AC power cord is plugged into a
replaced with a known good device. Verify whether or not the problem is corrected.
Should problems develop during installation or operation, this section is intended to
help locate, identify and correct these types of problems. Please follow the suggestions listed
All Magnum Ethernet products are designed to provide reliability and consistently
If not, go to Step 5 below. If the problem is corrected, the Magnum DS880 10/100
GarrettCom, Inc.by fax, phone or email (support@garrettcom.com) for assistance.
functioning electrical outlet. Use the PWR LEDs to verify each unit is receiving
Dual Speed Stackable Hub product, it is recommended that the problem device is
Magnum DS880 10/100 Dual Speed Stackable Hubs unit or if unknown, contact
Dual Speed Stackable Hub and its associated cables are functioning properly.
(About 90% of network downtime can be attributed to wiring and connector
that the various components of the network are interoperable.
the operation is also straightforward and is discussed in Section 4.
5.1 Before Calling for Assistance
GarrettCom Customer Support.
problems.)
power.

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form. Please
Include the date(s) that you purchased the products from your supplier.
All returns for repair must be accompanied by a Return Material Authorization
d. Any particular application that, when used, appears to create the problem;
including personal computers, workstations, terminals and printers; plus, the
to the occurrence of the problem. Any changes to system administration
Failure symptoms, including a full description of the problem.
(RMA) number. To obtain an RMA number, please use this URL -
Please be prepared to provide the following information.
Name and phone number of your contact person.
Packing List Number (or Sales Order Number)
c. The components involved in the problem;
procedures should all be noted in this record.
a. The nature and duration of the problem;
various network media types being used.
b. Situations when the problem occurs;
have the following information readily available:
Name of your company / institution
Serial Number (or Invoice Number)
5.2 When Calling for Assistance
Your shipping address · Date of installation · Product name

Should you need to ship the unit back to GarrettCom, please follow these instructions:
shipping protection. ( You may retain all connectors and this Installation Guide.)
products that are under warranty at no charge, and will return the warranty-repaired units to
This warranty will not be effective if, in the opinion of GarrettCom, the product
Please complete the warranty card as this acts as a product registration, and mail
GarrettCom, Inc. warrants its products to be free from defects in materials and
workmanship for a period of three (3) years from the date of shipment by GarrettCom.
components in the products that prove to be defective at no charge other than shipping
GarrettCom reserves the right to make a charge for handling and inspecting any
GarrettCom reserves the right to charge for the testing of non-defective units
under warranty. Testing and repair of product that is not under warranty will result in a
has been damaged by misuse, misapplication, or as a result of service or modification
GarrettCom will carefully test and evaluate all returned products, will repair
the sender with shipping charges prepaid (see Warranty Information, Appendix A, for
complete details). However, if the problem or condition causing the return cannot be
During this warranty period, GarrettCom will repair or, at its option, replace
This material may cause electro-static shock damage to the unit.
and handling, provided that the product is returned pre-paid to GarrettCom.
product returned for warranty repair which turns out not to be faulty.
duplicated by GarrettCom, the unit will be returned as:
it to GarrettCom within two weeks of your purchase.
No Problem Found.
5.4 Shipping and Packaging Information
47823 Westinghouse Dr.
Attn.: Customer Service
GarrettCom, Inc.
other than by GarrettCom.
customer (user) charge.
Fremont, CA 94539-7437

polarity connection, for example, will neither effect the hub, nor its power supply internally, nor
The power switch (included on premium-priced NEBS-certified units only) is used for
provides an Ethernet networking solution utilizing a special power supply in hubs with a proven
common for facilities to operate on 48VDC power. Such companies include regular and wireless
publishers, newspaper operations, brokerage firms and other facilities often use a battery backup
The 48VDC power option is designed using diodes inside on each DC power input
where 48 VDC power is used as the primary power source. The 48VDC power configuration
line behind the two external power connection terminals, so that the power from an external
Magnum DS880 Dual-Speed Hubs are easily installed in a variety of applications
With the exception of the power supply, all specifications and functions of
The solution is particularly useful in the telecommunication industry, where it is
companies. In addition, many high availability equipment services, such as broadcasters,
system to maintain operations in the event of a power failure. It is also frequently used for
telephone service providers, Internet Service Providers (ISPs) and other communication
SUPPLY
FUSE +
HUB POWER SWITCH
Power Consumption: Model DS880: 12 watt typical, 20 watts max.
computer system backup, management and operations monitoring equipment.
Magnum DS880-48VDC models are identical to those listed in Section 1.
powering the hub on and off when it is placed into or taken out of service.
B1.0 SPECIFICATIONS - FOR DUAL-SPEED DS880 HUBS
DC Power Connector: 3 terminals: “ - “, “GND”, “+”
A-
will it blow the fuse in the internal power supply.
Power Supply (Internal 48 VDC Option)
DC power is correctly applied to the two
inputs. It protects the hub from incorrect
source can only flow into the hub. This
allows the hub to operate only whenever
DC input connections. An incorrect
track record.

switch is included, located in the rear at the power input. This can be used in conjunction with
Operation of the Magnum DS880s with the optional 48VDC power supply is identical
procedure is very straightforward. To avoid the confusion of -48V or +48V power supply,
On the premium-priced NEBS-compliant Magnum DS880-48V models, an ON-OFF
This section describes the installation of the 48 VDC power source leads to the 48
use a digital voltmeter to measure the output voltage and figure out the +VE Lead. The
connected to the post leveled “+” and then the rest. Ensure that each lead is securely
identified as negative (-), positive (+), and chassis ground (GND). The actual connection
more +VE voltage terminal lead from the +48V or-48V power supply should be
VDC power terminal block on the Magnum DS880s. (see figure below).
ON
power connections, and as a RESET for the hub’s electronics.
Please refer to Section 5.0 for troubleshooting
to that of the standard AC-powered models.
the Magnum DS880s is located on the rear
The 48 VDC terminal block on
of the unit and is equipped with three (3)
screw-down lead posts. The leads are
of the terminal block.
B4.1 UL Requirements
tightened.
on Magnum DS880-48VDC