EN
GarrettCom logo
Official user manual

GarrettCom CSG14U

82 pages·584 KB·Switch·PDF·ENDEFRITNLJA
GarrettCom CSG14U
Table of Contents 30 sections CSG14U · Magnum CSG14 Gigabit Converter Switches · Installation and User Guide · CSG14 · … ShowHide
Page 1 of the GarrettCom CSG14U user manual — CSG14
Page 1 · click to enlarge
Page 1

CSG14U

Magnum CSG14 Gigabit Converter Switches

GarrettCom CSG14U — CSG14U diagram (page 1)
Fig. 1

Installation and User Guide

GarrettCom CSG14U — Installation and User Guide diagram (page 1)
Fig. 2 · Installation and User Guide
GarrettCom CSG14U — Installation and User Guide diagram (page 1)
Fig. 3 · Installation and User Guide
GarrettCom CSG14U — Installation and User Guide diagram (page 1)
Fig. 4 · Installation and User Guide

CSG14

GarrettCom CSG14U — CSG14 diagram (page 1)
Fig. 5
Page 2 of the GarrettCom CSG14U user manual — Installation and User Guide
Page 2 · click to enlarge
Page 2

Magnum TM CSG14 Series Gigabit Converter Switch

GarrettCom is a registered trademark and Magnum, Dymec, DynaStar, Personal

Switch, Link-Loss-Learn, S-Ring, Convenient Switch and Converter Switch

Installation and User Guide

UL is a registered trademark of Underwriters Laboratories

Part #84-00102Z Rev. G

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

are trademarks of GarrettCom, Inc.

Trademarks

Page 3 of the GarrettCom CSG14U user manual — Magnum TM CSG14 Series Gigabit Converter Switch
Page 3 · click to enlarge
Page 3

Switches contain no user serviceable parts. Attempted service by unauthorized

Copyright © 2008 GarrettCom, Inc. All rights reserved. No part of this publication may

GarrettCom, Inc. reserves the right to change specifications, performance characteristics

experienced with Magnum CSG14 10/100/1000 Mb/s Converter Switch

be reproduced without prior written permission from GarrettCom, Inc.

personnel shall render all warranties null and void. If problems are

products, consult Section 5, Troubleshooting, of this User Guide.

Printed in the United States of America

and/or model offerings without notice.

Page 4 of the GarrettCom CSG14U user manual — Magnum TM CSG14 Series Gigabit Converter Switch
Page 4 · click to enlarge
Page 4

This equipment generates, uses and can radiate frequency energy and if not

installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested and

found to comply with the limits for a Class A computing device in accordance with the

specifications in Subpart J of Part 15 of FCC rules, which are designed to provide

reasonable protection against such interference when operated in a commercial

environment. Operation of this equipment in a residential area is likely to cause

interference, in which case the user, at his/her own expense, will be required to take

Radio Frequency Interference Statement

whatever measures may be required to correct the interference.

Federal Communications Commission

Page 5 of the GarrettCom CSG14U user manual — Magnum TM CSG14 Series Gigabit Converter Switch
Page 5 · click to enlarge
Page 5

which has suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable

2. 48VDC products shall be installed with a readily accessible disconnect device in the building installation supply circuit to the product.
3. This product shall be provided with a maximum 10A DC Listed fuse or
4. The external power supply for DC units shall be Listed, Direct Plug In

power unit, marked Class 2, or listed ITE Power Supply, marked LPS,

5. Product does not contain user replaceable fuses. Any internal fuses can

ONLY be replaced by GarrettCom personnel through the RMA process.

1. This product is to be installed Only in Restricted Access Areas

(Dedicated Equipment Rooms, Electrical Closets, or the like).

circuit breaker in the supply circuit when connected to a 48V

Electrical Safety requirements:

rated output current.

centralized source.

Page 6 of the GarrettCom CSG14U user manual — Phone (510) 438-9071
Page 6 · click to enlarge
Page 6

Please use the mailing address, phone and fax numbers and email address listed below:

Websitehttp://www.GarrettCom.com
Emailsupport@ garrettcom.com

47823 Westinghouse Drive Fremont, CA 94539

GarrettCom, Inc.

Phone (510) 438-9071

Fax (510) 438-9072 · Contacting GarrettCom, Inc

Page 7 of the GarrettCom CSG14U user manual — Phone (510) 438-9071
Page 7 · click to enlarge
Page 7
Page 7 of the GarrettCom CSG14U user manual — Phone (510) 438-9071
Page 8 of the GarrettCom CSG14U user manual — 4.0 OPERATION ....................................................................................... 62
Page 8 · click to enlarge
Page 8

3.4 DIN-Rail mounting option 49

3.5 Power Requirements for CSG14 Series Switches 50

3.6 Powering the CSG14 with 12V, 24V or –48VDC power input 51

3.7 CSG14 Series, DC-powered, -48, 24 and 12VDC Installation 53

3.8 Connecting Ethernet Media 55

3.8.1 Connecting Twisted Pair (RJ-45, CAT 3, CAT 5 or CAT 6,

Unshielded or Shielded) 56

3.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)” ... 57

3.8.3 Connecting Fiber Optic SC-type, "Snap-In" 58

3.8.4 Installing LC-type SFP module,“Small Form Pluggable (SFP)” 58

3.8.5 Connecting Single-Mode Fiber Optic 58

3.8.6 Power Budget Calculations for CSG14 Series, Fiber Media 59

3.8.7 Connections to NICs which support Auto-Negotiation 61

4.0 OPERATION 62

4.1 Triple-Speed Functionality, and Switching 62

4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing 64

4.3 Dual LEDs, Top-front and in End with ports 65

Page 9 of the GarrettCom CSG14U user manual — Revisions
Page 9 · click to enlarge
Page 9

5.0 TROUBLESHOOTING 66

5.1 Before Calling for Assistance 67

5.2 When Calling for Assistance 68

5.3 Return Material Authorization (RMA) Procedure 70

5.4 Shipping and Packaging Information 72

APPENDIX A: WARRANTY INFORMATION 73

Rev G 05/09updated Latency specification (pg. 2), corrected Operating temp. (pg. 3)
Rev F 04/09revised Fiber Port connector spec. to “Single-mode” for “LX10” and
Rev A 05/08Initial release of this user manual for CSG14 Converter Switches

added mounting hole location drawing (page 43)

Rev E 02/09updated 100Base-FX SFP part nos. (page 15)
Rev B 08/08added PCSG14P (PoE version)

“LX25” on pages 12 and 13

Rev C 11/08removed PCSG14P model,
Rev D 12/08added CSG14U model

Revisions

Page 10 of the GarrettCom CSG14U user manual — 1.0 SPECIFICATIONS
Page 10 · click to enlarge
Page 10

Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.

Filter and Forward Rate from 1000Mbps ports: 1,488,000 pps max.

Filter and Forward Rate from 100Mbps ports: 148,800 pps max.

1000Mb: Ethernet IEEE 802.3ab and 802.3z 1000Base-T, -SX, -LX and -ZX 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3z

Data Rate10Mbps, 100Mbps, 1000Mbps
Processing typeStore and Forward, non-blocking

Packet-Processing Between Domains

Address buffer age-out time: 300 sec.

Auto-learning1K-address table

1.0 SPECIFICATIONS

1.1 Technical Specifications Ports Performance

Network Standards

Page 11 of the GarrettCom CSG14U user manual — Path Delay Value : 50 BT on all ports
Page 11 · click to enlarge
Page 11

10BASE-T (Unshielded twisted pair) 100 m (328 ft) 10BASE-FL, Fiber optic 2 km (6,562 ft) 10BASE-FL, Single-mode Fiber optic 10 km (32,810ft)

100BASE-TX (CAT 5 UTP) 100 m (328 ft) 100BASE-FX, half-duplex: (multi-mode) 412 m (1350 ft) 100BASE-FX, full duplex: (multi-mode) 2 km (6,562 ft) 100BASE-FX, half-duplex: (single-mode) 412 m (1350 ft) 100BASE-FX, full duplex: (single-mode) 20 km (65,620 ft) 100BASE-FX, full duplex: (single-mode, long reach) 40 km (131,240 ft) 1000BASE-T (CAT5E OR CAT6 recommended) 100 m (328 ft) 1000BASE-SX, full duplex, multi-mode (62.5um) 220 m (722 ft) 1000BASE-SX, full duplex, multi-mode (50um) 550 m (1804 ft)

Packet buffers memory64KB, dynamically shared on all domains
Latency (not including packet time)1000 to 1000Mbps: <3 μ s
100 to 100Mbps<5 μ s 10 to 10Mbps: <18 μ s
100 to 10 Mbps<5 μ s 10 to 100Mbps: <15 μ s

Path Delay Value : 50 BT on all ports

Maximum Ethernet Segment (or Domain) Lengths

Page 12 of the GarrettCom CSG14U user manual — Path Delay Value : 50 BT on all ports
Page 12 · click to enlarge
Page 12

1000BASE-LX, full duplex, single-mode (9um) 5 km (16404 ft) 1000BASE-ZX, full duplex, single-mode (9um) >70 km (229,659 ft)

CSG14H / CSG14UH: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL)

CSG14P / CSG14UP: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL)

-40ºF to 185ºF (-40ºC to 85ºC) Short term per IEC Type tests

-40ºF to 185ºF (-40ºC to 85ºC) Short term per IEC Type tests

Altitude (All models)-200 to 50,000ft. (-60 – 15,000 m)
Ambient Relative Humidity5% to 95% (non-condensing)
All models-40 º F to 212 º F (-40 º C to 100 º C)

Conformal Coating (optional) for humidity protection

Cold Start:

CSG14H / CSG14UH to -20ºC

CSG14P / CSG14UP to -40ºC

Operating Environment · Storage Temperature,

Page 13 of the GarrettCom CSG14U user manual — Packaging:
Page 13 · click to enlarge
Page 13

Convection on the CSG14 Series models. The hardened (H) factory floor and premium (P)

temperature un-controlled location models have closed cases to withstand dirt and use

special thermal techniques to transfer heat to the outside of the case for cooling.

3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x 2.5 cm)

CSG14UH / CSG14UP6.1 oz. (173g)
EnclosureRugged sheet metal (Aluminum)
WeightCSG14H / CSG14P: 9 oz. (255g)
Power supply, –Hd, and Hi5.8 oz (165g)
–Pd, and -Pi7.9 oz (225g)

Dimensions of the Switch unit:

and altitude.

Cooling Method:

Packaging:

Page 14 of the GarrettCom CSG14U user manual — POWER SUPPLY
Page 14 · click to enlarge
Page 14

All models have a (8-15) VDC output with 6ft long cord and a 2.5mm center +ve jack. The

International (-Hi) models. Factory floor temperature rated. Input: IEC 320 connector on

North America (-Hd) models. Hardened, factory floor temperature rated. Input: 6ft AC

power cord to IEC 320 connector on the 100-240vac 47-63Hz external power adapter.

the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord

power supplies are temperature rated to match the Converter Switch ratings.

AC POWER SUPPLY (using an external power adapter):

Factory Floor (H) Ratings (-25 to 60°C)

Output12vdc, 1.25Amps

Output: 12vdc, 1.25Amps.

POWER SUPPLY

Page 15 of the GarrettCom CSG14U user manual — AC POWER SUPPLY (using an external power adapter):
Page 15 · click to enlarge
Page 15
GarrettCom CSG14U — AC POWER SUPPLY (using an external power adapter): diagram (page 15)
Fig. 6 · AC POWER SUPPLY (using an external power adapter):
GarrettCom CSG14U — AC POWER SUPPLY (using an external power adapter): diagram (page 15)
Fig. 7 · AC POWER SUPPLY (using an external power adapter):
GarrettCom CSG14U — AC POWER SUPPLY (using an external power adapter): diagram (page 15)
Fig. 8 · AC POWER SUPPLY (using an external power adapter):

Temperature un-controlled Premium (P) Ratings (-40 to 75°C)

external power adapter. Requires a user supplied power cord.

Direct DC POWER SUPPLYbuilt-in terminal block for

12V DC internal (range of 8.0 to 15V DC) 24V DC internal (range of 18 to 36V DC). -48V DC internal (range of 36 to 60V DC), -, ground

North America (-Pd) models. Outdoor temperature rated.

Input6ft AC power cord to IEC 320 connector on the100-

International (-Pi) models. Outdoor temperature rated.

InputIEC 320 connector on the 100-240vac 47-63Hz

240vac 47-63Hz external power adapters. Output: 12vdc, 2Amps.

+, -, ground along with 12VDC jack

Output: 12vdc, 2Amps.

Page 16 of the GarrettCom CSG14U user manual — AC POWER SUPPLY (using an external power adapter):
Page 16 · click to enlarge
Page 16
Two Fiber optic portsThe CSG14U series is 100Base-FX or 1000Base-SX /-LX

It is shielded 8-pin female connector for shielded (STP) and unshielded (UTP)

/ -ZX with a “fiber flavor” choice of multimode or singlemode SFP connectors.

They are shielded 8-pin female connectors for shielded (STP) and unshielded

“fiber flavor” choice of multimode or singlemode SC, SLC, SFP connectors.

One Fiber optic portThe CSG14 series is 1000Base-SX / -LX / -ZX with a

the DC terminal block. Power supply protection is provided by internal diodes.

Two RJ-45 Ports: supports 10/100/1000Mbps with auto cross (MDIX).

One RJ-45 Port: supports 10/100/1000Mbps with auto cross (MDIX).

Port Connectors (CSG14UH / CSG14UP:

Port Connectors (CSG14H / CSG14P:

Power Consumption: See Section 3.6.

(UTP) Cat 3, 4, 5 cables.

Cat 3, 4, 5 cables.

Page 17 of the GarrettCom CSG14U user manual — AC POWER SUPPLY (using an external power adapter):
Page 17 · click to enlarge
Page 17

User may select 100Mb speed via DIP switch on the back of the unit

Each SFP port is individually speed-selectable

Fiber port default is FDX (Full-Duplex)

RJ45’s are triple-speed auto-negotiating

Each SFP port is factory set to Gb speed

Switches (CSG14UH / CSG14UP)

Switches (CSG14H / CSG14P)

setting to take effect.

Page 18 of the GarrettCom CSG14U user manual — LK/ACT
Page 18 · click to enlarge
Page 18

LK/ACT

POWER

LK/ACT

LK/ACT

PORT 3

PORT 1 PORT 2 PORT 3

traffic, BLINKING for Activity

Gb per portSteady ON for 1000Mbps; OFF for
Fiber portLK/ACT: Steady ON for Link with no

LED Indicators (Two sets) top-front and end with ports

100Mbps or 10Mb speed LK/ACT per port: Steady ON for LINK (LK) with no

traffic, BLINKING for Activity

10/100/Gb per RJ45 portSteady ON for 100Mb, OFF for 10Mb,
POWERSteady ON when power applied
POWERSteady ON when power applied
Top-Front(shown)

End with Ports:

Show 4 more labels / short text on this page
Gb · Gb · Gb · BLINKING for Gb
Page 19 of the GarrettCom CSG14U user manual — LK/ACT
Page 19 · click to enlarge
Page 19

Mean Time Between Failure (MTBF) – over15 years, Telcordia (Bellcore) Method

UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A.

IEC61850 EMC and Operating Conditions Class C Power Substations

WarrantyThree years, return to factory Made in USA
Rack-mount optionMC14-TRAY, see http://www.garrettcom.com/mc_tray.htm
P modelIEEE P1613 Env. Std for Electric Power Substations
P modelNEMA TS-2 and TEES for traffic control equipment
P modeldesigned for UL 2043 above-the-ceiling installation
DIN-Rail mounting optionModel # DIN-RAIL MC2 (see Section 3.4)

Metal mounting clips for panel mounting: included

Agency Approvals and Standards Compliance:

NEBS L3 and ETSI compliant.

Mounting options

Page 20 of the GarrettCom CSG14U user manual — LK/ACT
Page 20 · click to enlarge
Page 20

factory floor (-25 to 60C) using a direct DC ( 8-15VDC) and/or external

CSG14H-ff-Hd, Hi = Hardened (H), two 10/100/1000Mb RJ-45+ one 1000Mb Fiber port for

except AC hardened power supply is not included

but includes DIN-RAIL-MC2 mounting option.

except 24VDC power input replaces 12VDC.

except -48VDC power input replaces 24VDC

AC hardened power supply (included).

CSG14H-ff-24VDC = Same as CSG14H-12VDC model,

CSG14HR-ff-24VDC = Same as CSG14H-24VDC model,

CSG14H-ff-48VDC = Same as CSG14H-24VDC model,

CSG14H-ff-12VDC = Same as CSG14H model,

1.2 Summary of models and descriptions:

CSG14H (Hardened Model) for 1000Mb fiber

Page 21 of the GarrettCom CSG14U user manual — LK/ACT
Page 21 · click to enlarge
Page 21

CSG14P-ff-48VDC = Same as CSG14P-24VDC model, except -48VDC input replaces 24VDC.

CSG14P-ff-Pd, Pi = Premium (P), two 10/100/1000Mb RJ-45+ one 1000Mb Fiber port for un-

controlled(outdoor) (-40 to 75C) using direct DC (8-15VDC) and/or

CSG14P-ff-12VDC = Same as CSG14P-Pd, Pi, except AC Premium Power Supply is not

“ESX”= 1000Base-SX Extended1310nm multi-mode fiber optic with SC type connector, 2 km
“LX10”= 1000Base-LX-SLC1310nm single-mode fiber optic with LC type connector, 10 km

“SX” = 1000Base-SX-SC: 850nm multi-mode fiber optic with SC type connector, 550 m.

external AC premium power supply (included).

but includes DIN-RAIL-MC2 mounting option.

except 24VDC power input replaces 12VDC.

The “ff” field is for selection of the desired “fiber flavor” as listed below.

CSG14P-ff-24VDC = Same as CSG14P-12VDC model,

CSG14PR-ff-24VDC = Same as CSG14P-24VDC model,

CSG14P (Premium Model) for 1000Mb fiber

Fiber Port Connectors (CSG14H / CSG14P):

included.

Page 22 of the GarrettCom CSG14U user manual — LK/ACT
Page 22 · click to enlarge
Page 22
“SFP-ESX”= 1000Base-SX Extended1310nm multi-mode fiber optic with LC type connector, 2 km

CSG14UH-ff-Hd, Hi = Hardened (H), one 10/100/1000Mb RJ-45+ two 1000Mb Fiber ports for

factory floor (-25 to 60C) using a direct DC ( 8-15VDC) and/or external

“LX25” = 1000Base-LX-SLC1310nm single-mode fiber optic with LC type connector, 25 km
“ZX40” = 1000Base-ZX-SLC1550nm single-mode fiber optic with LC type connector, 40 km
“ZX70”= 1000Base-ZX-SLC1550nm single-mode fiber optic with LC type connector, 70 km

“SFP” = open SFP transceiver slot in the fiber position. (order SFP as a separate item)

except AC hardened power supply is not included

“SFP-LX10”= 1000Base-LX-SLC1310nm single-mode SFP, 10 km
“SFP-LX25”= 1000Base-LX-SLC1310nm single-mode SFP, 25 km
“SFP-ZX40”= 1000Base-ZX-SLC1550nm single-mode SFP, 40 km
“SFP-ZX70”= 1000Base-ZX-SLC1550nm single-mode SFP, 70 km

AC hardened power supply (included).

“SFP-SX”= 1000Base-SX-LC850nm multi-mode SFP, 550 m

CSG14UH-ff-24VDC = Same as CSG14UH-12VDC model,

CSG14UH-ff-12VDC = Same as CSG14UH model,

CSG14UH (Hardened Model) for 1000Mb fiber

Page 23 of the GarrettCom CSG14U user manual — LK/ACT
Page 23 · click to enlarge
Page 23

CSG14UP-ff-Pd, Pi = Premium (P), one 10/100/1000Mb RJ-45+ two 1000Mb Fiber ports for un-

CSG14UP-ff-48VDC = Same as CSG14UP-24VDC model, except -48VDC input replaces 24VDC

controlled(outdoor) (-40 to 75C) using direct DC (8-15VDC) and/or

CSG14UP-ff-12VDC = Same as CSG14UP-Pd, Pi, except AC Premium Power Supply is not

but includes DIN-RAIL-MC2 mounting option.

external AC premium power supply (included).

but includes DIN-RAIL-MC2 mounting option.

except 24VDC power input replaces 12VDC.

except -48VDC power input replaces 24VDC

except 24VDC power input replaces 12VDC.

CSG14UHR-ff-24VDC = Same as CSG14UH-24VDC model,

CSG14UH-ff-48VDC = Same as CSG14UH-24VDC model,

CSG14UP-ff-24VDC = Same as CSG14UP-12VDC model,

CSG14UPR-ff-24VDC = Same as CSG14UP-24VDC model,

CSG14UP (Premium Model) for 1000Mb fiber

included.

Page 24 of the GarrettCom CSG14U user manual — LK/ACT
Page 24 · click to enlarge
Page 24
“SFP-ESX”= 1000Base-SX Extended1310nm multi-mode fiber optic with LC type connector, 2 km

Other Tray configurations with power supplies and power cabling included - See Section 3.3

“SFP” = open SFP transceiver slot in the fiber position. (order SFP as a separate item)

DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one CSG14 Series Switch,

MC14-TRAY = 19” Rack-mount tray for 14-series Switch models, up to 16 units

Conformal Coating (for high humidity and “tropical” applications) - request quote.

The “ff” field is for selection of the desired “fiber flavor” as listed below.

“SFP-LX10”= 1000Base-LX-SLC1310nm single-mode SFP, 10 km
“SFP-LX25”= 1000Base-LX-SLC1310nm single-mode SFP, 25 km
“SFP-ZX40”= 1000Base-ZX-SLC1550nm single-mode SFP, 40 km
“SFP-ZX70”= 1000Base-ZX-SLC1550nm single-mode SFP, 70 km
“SFP-SX”= 1000Base-SX-LC850nm multi-mode SFP, 550 m

“SFP100P-FXSM15”= 100Base-FX, single-mode SFP, 15Km

“SFP100P-FXSM40”= 100Base-FX, single-mode SFP, 40Km

“SFP100P-FXMM2”= 100Base-FX, multi-mode SFP, 2Km

Fiber Port Connectors (CSG14UH / CSG14UP):

See Section 3.4

Accessories

Page 25 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 25 · click to enlarge
Page 25

This section describes CSG14 Series models, including appearance, features and

product; notify the carrier immediately of any damage, which you believe occurred during

shipment or delivery. Inspect the contents of this package for any signs of damage and

Examine the shipping container for obvious damage prior to installing this

1 External Power Supply, (for -Hd, -Hi, -Pd and -Pi models only)

1 set Metal panel mounting clips and screws (2 each)

1 User Guide (this manual)

1 Magnum CSG14 Series Converter Switch unit,

2.1 Inspecting the Package and the Product

ensure that the items listed below are included.

2.0 INTRODUCTION

This package should contain:

typical applications.

Page 26 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 26 · click to enlarge
Page 26

container. Be sure to keep the shipping container should you need to ship the unit at a later

date. In the event there are items missing or damaged contact your supplier. If you need to

return the unit, use the original shipping container. Refer to Section 5 Troubleshooting, for

10Mb Fiber port built in covers the full range of application environments, with Hardened

10/100/1000 copper Switch, and you have the Converter Switch, a flexible edge-of-the- network Ethernet product. Add in fiber port choices for all multi-mode and single-mode

The Magnum CSG14 family of Converter Switches with a 1000Mb, 100Mb or

fiber connector types plus AC or DC input power selection and multiple application

Remove the Magnum CSG14 Series Converter Switch from the shipping

Combine a 10, 100 or 1000Mb Fiber Media Converter and a two-port

environments, and you have the Magnum CSG14 Converter Switch family.

2.2.1 CSG14H / CSG14P Product Description

specific return procedures.

2.2 Product Description

Page 27 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 27 · click to enlarge
Page 27

offers the best price-to-value ratio for each user and installation. Where a Media Converter

jobs. In addition to a Hardened AC power option and jack, terminals for internal DC power

(factory floor), and Premium-rated (outdoor) versions. Extra features for heavy-duty and

choices at 8 to15V, 24V or -48V DC are included. The ambient temperature rating of –25

dirt, moisture, smoke and insects. Mounting options include stand-alone panel mounting,

extended temperature operation ranges are included selectively in the Hardened factory-

floor and Premium-rated outdoor models. This selection of models and fiber port types

might have been used, a Converter Switch offers a better value. The compact package is

ideal for network edge installations, and is able to be conveniently mounted to suit any

constructed using special thermal techniques and a metal case for heavy-duty industrial

to 60C is for industrial use. No internal airflow is required for cooling, so it resists dust,

The Magnum CSG14H Hardened units are for the office and factory floor

applications. The CSG14H models are built with high-grade components and are

DIN-Rail, or rack-mount tray.

application.

Page 28 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 28 · click to enlarge
Page 28

used outdoors, the CSG14P should be protected from falling rain. Mounting options include

The CSG14 series provides switching between two 10/100/1000 auto-negotiating

single-mode. The plug-and-play, energy-efficient, and flavor rich fiber features make this

various temperature ranges enables deployment in various industrial environments. And, it

applications (-40 to 75C), typically located outdoors. The CSG14P models are built with

premium-grade extended temperature components, and use similar thermal techniques as

the CSG14H Hardened units. In addition to a Premium-rated AC power option and jack,

terminals for internal DC power choices at 8 to15V, 24V or -48V DC are included. When

The Magnum CSG14P Premium-rated units are for temperature un-controlled

sleek multi-purpose Switch convenient and cost-effective for the user. The selection of

uses very little space. Providing the combination of Media Converter with Switch, the

copper ports and one 1000Mb fiber port which may be SC, LC or SFP multi-mode or

CSG14 Series is an ideal choice for edge-of–the-network applications.

stand-alone panel mounting, DIN-rail, or rack-mount tray.

Page 29 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 29 · click to enlarge
Page 29

cooling, so the CSG14H resist dust, dirt, moisture, smoke and insects. Choices of models

25°C to + 60°C depending on the power source used. Storage temperature rating is –40°C to + 100°C

GarrettCom CSG14U — 2.0 INTRODUCTION diagram (page 29)
Fig. 9

for external AC or internal DC power are available. Ambient operating temperature is –

Fig 2.2.1a

CSG14H with 1000Mb SC connector

heavy-duty industrial applications no air inflow is required for

The ORANGE labeled Magnum CSG14H hardened units (as

shown in Fig 2.2.1a) are designed for office and wiring closet

environments and factory floor/Industrial applications. Using

special thermal techniques and a sealed rugged metal case for

Page 30 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 30 · click to enlarge
Page 30

DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC power are

GarrettCom CSG14U — 2.0 INTRODUCTION diagram (page 30)
Fig. 10

available. Ambient operating temperature is between –40°C to +75°C depending on the

power source used. Storage temperature rating is between –40°C to +100°C.

Fig 2.2.1b

CSG14P with 1000Mb LC connector

premium-grade extended temperature components, the CSG14P

units use similar thermal techniques to the CSG14H hardened

The RED labeled Magnum CSG14P Series (as shown in Fig.

units for cooling. Mounting options include panel mounting,

2.2.1b) are premium rated units suitable for temperature un- controlled outdoor applications. Specially designed with

Page 31 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 31 · click to enlarge
Page 31

Two sets of LEDs indicating the operating status of ports are mounted on the top

and front (for extra viewing advantage while rack-mounted). For each port, there are Link

The single fiber port on the CSG14 is multi-mode with an SC connector or small

The front side of the unit has two twisted-pair 10/100/1000Mb switch ports and

and Activity (LK/ACT) LED’s on the top indicating that the media cables are connected

The external DC power plug connector and/or “jack” and the internal DC input

one 10, 100 or 1000Mb fiber port. Both the RJ-45 ports of the CSG14 Series Converter

switches support auto cross (MDIX) operation performing the autocross function under

auto-negotiation mode only. The CSG14 models are factory configured at Full Duplex.

repeated on the front as LA1 (port 1), LA2 (port 2), and LA3 (port 3). There is a power

correctly and showing, by blinking, when there is traffic. The LK/ACT LED’s are

(PWR) indicator on the front of the unit to validate that the unit is turned ON.

terminal is provided on the rear of the unit.

form-factor connector (LC single-mode).

Page 32 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 32 · click to enlarge
Page 32

be plugged in. It can also handle any 100Mb fiber media type and distance in the same way,

media attachment, there is a 10/100/1000 auto-negotiating RJ-45 port. Where Gb Ethernet

fiber media distance with a selection of Gb SFP fiber transceivers, up to two of which can

100Mb Fiber ports available to cover the full range of application environments, with Hardened (factory floor), and Premium-rated (outdoor) versions. Extra features for heavy-

duty and extended temperature operation ranges are included selectively in the Hardened

factory-floor and Premium-rated outdoor models. This selection of models and fiber port

Converter Switch. It can handle any Gb fiber type – multi-mode and single-mode – and

with a selection of 100Mb SFP fiber transceivers that similarly plug in. And, for copper

The latest technology of SFP fiber transceivers has been integrated into the

types offers the best price-to-value ratio for each user and installation. Where a Media

Magnum Gb Converter Switch package to produce the Magnum CSG14U Universal

The Magnum CSG14U family of Converter Switches have two 1000Mb or

2.2.2 CSG14UH / CSG14UP Product Description

is in use, the CSG14U converts all media combinations.

Page 33 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 33 · click to enlarge
Page 33

jobs. In addition to a Hardened AC power option and jack, terminals for internal DC power

applications (-40 to 75C), typically located outdoors. The CSG14UP models are built with

the CSG14UH Hardened units. In addition to a Premium-rated AC power option and jack,

package is ideal for network edge installations, and is able to be conveniently mounted to

choices at 8 to15V, 24V or -48V DC are included. The ambient temperature rating of –25

dirt, moisture, smoke and insects. Mounting options include stand-alone panel mounting,

The Magnum CSG14UP Premium-rated units are for temperature un-controlled

premium-grade extended temperature components, and use similar thermal techniques as

Converter might have been used, a Converter Switch offers a better value. The compact

constructed using special thermal techniques and a metal case for heavy-duty industrial

to 60C is for industrial use. No internal airflow is required for cooling, so it resists dust,

The Magnum CSG14UH Hardened units are for the office and factory floor

applications. The CSG14UH models are built with high-grade components and are

DIN-Rail, or rack-mount tray.

suit any application.

Page 34 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 34 · click to enlarge
Page 34

single-mode. The plug-and-play, energy-efficient, and flavor rich fiber features make this

various temperature ranges enables deployment in various industrial environments. And, it

terminals for internal DC power choices at 8 to15V, 24V or -48V DC are included. When

negotiating copper port and two 100 or 1000Mb fiber ports which are SFP multi-mode or

sleek multi-purpose Switch convenient and cost-effective for the user. The selection of

uses very little space. Providing the combination of Media Converter with Switch, the

used outdoors, the CSG14UP should be protected from falling rain. Mounting options

The CSG14U series provides switching between one 10/100/1000 auto-

CSG14U Series is an ideal choice for edge-of–the-network applications.

include stand-alone panel mounting, DIN-rail, or rack-mount tray.

Page 35 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 35 · click to enlarge
Page 35
GarrettCom CSG14U — 2.0 INTRODUCTION diagram (page 35)
Fig. 11

insects. Choices of models for external AC or internal DC power are available. Ambient

operating temperature is –25°C to + 60°C depending on the power source used. Storage

Fig 2.2.2a

CSG14UH with two SFP slots

cooling, so the CSG14UH resist dust, dirt, moisture, smoke and

The ORANGE labeled Magnum CSG14UH hardened units (as

heavy-duty industrial applications no air inflow is required for

shown in Fig 2.2.2a) are designed for office and wiring closet

environments and factory floor/Industrial applications. Using

special thermal techniques and a sealed rugged metal case for

temperature rating is –40°C to + 100°C

Page 36 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 36 · click to enlarge
Page 36

Ambient operating temperature is between –40°C to +75°C depending on the power source

GarrettCom CSG14U — 2.0 INTRODUCTION diagram (page 36)
Fig. 12

rack-mount tray. Choices of models for external AC or internal DC power are available.

Fig 2.2.2b

CSG14UP with two SFP slots

2.2.2b) are premium rated units suitable for temperature un- controlled outdoor applications. Specially designed with premium-

grade extended temperature components, the CSG14UP units use

cooling. Mounting options include panel mounting, DIN-rail, or

used. Storage temperature rating is between –40°C to +100°C.

The RED labeled Magnum CSG14UP Series (as shown in Fig.

similar thermal techniques to the CSG14UH hardened units for

Page 37 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 37 · click to enlarge
Page 37

two 100 or 1000Mb fiber ports. The RJ-45 port of the CSG14U Series Converter switches

Two sets of LEDs indicating the operating status of ports are mounted on the top

and front (for extra viewing advantage while rack-mounted). For each port, there are Link

The two fiber ports on the CSG14U are multi-mode or single-mode with a small

The external DC power plug connector and/or “jack” and the internal DC input terminal is

The front side of the unit has one twisted-pair 10/100/1000Mb switch port and

and Activity (LK/ACT) LED’s on the top indicating that the media cables are connected

repeated on the front as LA1 (port 1), LA2 (port 2), and LA3 (port 3). There is a power

negotiation mode only. The CSG14U models are factory configured at Full Duplex.

correctly and showing, by blinking, when there is traffic. The LK/ACT LED’s are

support auto cross (MDIX) operation performing the autocross function under auto-

(PWR) indicator on the front of the unit to validate that the unit is turned ON.

form-factor connector (LC multi-mode or LC single-mode).

provided on the rear of the unit.

Page 38 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 38 · click to enlarge
Page 38

Each frame (or packet) is loaded into the Switch’s memory and inspected before forwarding

2.3 Frame Buffering and Latency The Magnum CSG14 Series Converter Switches are store-and-forward switches.

can occur. This technique ensures that all forwarded frames are of a valid length and have

the correct CRC, i.e. they are good packets. This eliminates propagation of bad packets,

While other switching technologies such as "cut-through" or "express" impose

minimal frame latency, they will also permit bad frames to propagate out to the Ethernet

there is no way to filter frames with a bad CRC (the entire frame must be present in order

traffic congestion, especially at peak activity. Since collisions and bad packets are more

which are a result of late collisions, to be forwarded to add to the network traffic. Since

for CRC to be calculated), the result of indiscriminate cut-through forwarding is greater

segments connected. The "cut-through" technique permits collision fragment frames,

likely when traffic is heavy, the result of store-and-forward operation is that more

To minimize the possibility of dropping frames on congested ports, each

enabling all of the available bandwidth to be used for valid information.

bandwidth is available for good packets when the traffic load is greatest.

Page 39 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 39 · click to enlarge
Page 39

storage. (Many other switches have their packet buffer storage space divided evenly across

all ports, resulting in a small, fixed number of packets to be stored per port. When the port

aggregate density, the Magnum CSG14 Series Converter Switches are constantly adapting

When the Switch detects that its free buffer queue space is low, the Switch sends

buffering and processing resumes. This flow-control sequence occurs in a small fraction of

Magnum CSG14 Series Converter Switch dynamically allocates buffer space from 64Kb

memory pool, ensuring that heavily used ports receive very large buffer space for packet

capability for the maximum resources of the Magnum CSG14 Series unit to be applied to

industry standard (full-duplex only) PAUSE packets out to the devices sending packets to

which allows a traffic catch-up to occur without dropping packets. Then, normal packet

all traffic loads, even when the traffic activity is unbalanced across the ports. Since the

cause “flow control”. This tells the sending devices to temporarily stop sending traffic,

traffic on an operating network is constantly varying in packet density per port and in

buffer fills up, dropped packets result.) This dynamic buffer allocation provides the

internally to provide maximum network performance with the least dropped packets.

a second and is transparent to an observer. See Section 4.6 for additional details.

Page 40 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 40 · click to enlarge
Page 40

from entering by forcing a collision signal on all receiving half-duplex ports in order to stop

Another feature implemented in Magnum CSG14 Series Converter Switches is a

collision-based flow-control mechanism (when operating at half-duplex only). When the

forwarded to its destination) of the CSG14 Series Converter Switches varies with the port-

switches. For 10 Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the

Switch detects that its free buffer queue space is low, the Switch prevents more frames

The latency (the time the frame spends in the Switch before it is sent along or

speed types. The length of the frame is a variable as it is with all store-and-forward

latency is 15 microseconds plus the packet time at 10 Mb. For 100Mb-to-100Mb

forwarding, the latency is 5 microseconds plus the packet time at 100Mb.

incoming traffic.

Page 41 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 41 · click to enlarge
Page 41

2.4 Features and Benefits „ Full 1000Mb, 100Mb or 10 Mb switching services for high performance

giving each port’s segment a full 1000Mb, 100Mb or 10 Mb of bandwidth.

inexpensively connect a Twisted Pair and fiber network with 10Mb, 100Mb

1000Mb fiber port allows the user to convert the media from copper to fiber

Magnum CSG14 Series Switches offer the ideal solution to efficiently and

or 1000Mb and help to expand the Ethernet network in a very convenient

Magnum CSG14 Series Switches provide Fast Ethernet switching on all

„ Choice of 10, 100 or 1000Mb Fiber option, more efficient than media

Designed as a multi-purpose media converter and Switch, the 10, 100 or

ports. They perform high-speed filter/forward operations on the traffic,

„ Reduces Network Costs and provide economical solution

and economical way.

Ethernet LANs · converter

Page 42 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 42 · click to enlarge
Page 42

top) of LEDs to provide status information when viewed at almost any angle

CSG14 Series have a robust design and are packaged in a rugged sheet metal

domains. Internal address tables are self-learning, enabling users to change

The Magnum CSG14 Series Switches operate as hardware switches, only

Each CSG14 Series Converter Switch is equipped with two sets (front and

„ Installation is “Plug and Play”, operation is transparent to software

forwarding those packets from each domain that are needed on the other

port connections or 10/100/1000 domains without affecting operations.

or mounting arrangement whether rack (MC14- Tray) or wall-mounted.

enclosure to ensure high reliability and durability even when placed in

and the other RJ-45 port can be used as diagnostic port or for more

„ Two sets of LEDs for viewing status from any angle.

„ Rugged metal case, Industrial grade

industrial or outdoor applications.

connectivity.

Page 43 of the GarrettCom CSG14U user manual — 2.0 INTRODUCTION
Page 43 · click to enlarge
Page 43

The Magnum CSG14P Premium rated versions of Converter Switches have

installed in small spaces in cabinets, on table tops, in racks, wall or DIN rail

„ Qualified to use for temperature un-controlled “outdoor” application

an ambient temperature rating between –40C to +75C for DC models and

Featuring a compact aluminum case with an external AC and internal DC

All the Magnum CSG14 Series Switches are featured with MDIX (auto-

cross), which easily allow cascading with other Switch Hubs or media

power supply, Magnum CSG14 Series of Converter Switches can be

„ Efficient Compact design, for all purpose convenient mounting

qualify for temperature un-controlled “outdoor” application.

„ MDIX ports to eliminate cross-over cable while cascading

mounted and in trays such as the Magnum MC14-TRAY.

converters, without using the cross-over cable.

Page 44 of the GarrettCom CSG14U user manual — 2.5 Applications for CSG14 Series Converter Switches
Page 44 · click to enlarge
Page 44

Enriched with the two tier “O-R” hardness rating flavors (Orange –“Hardened”,

of-the-network connectivity solutions offered by Magnum Converter Switches are focused

The compactly designed Magnum CSG14 Series act as very useful tools in the modern life

support a mixed environment of 10 Mbps, 100Mbps and 1000Mbps users with copper and

negotiating copper ports together with the 10, 100 or 1000Mbps fiber port choices and the

locations experiencing a need to scale the LAN quickly and cost effectively. The CSG14Ps

environment enabling users to scale their networks quickly and cost effectively. The edge-

environmental, Magnum CSG14 Series Converter Switches fit very well in almost any

on providing easier, more economical and ultra-reliable industrial application products.

availability the industry standard fiber connectors, enable easy interfacing with existing

of fast expanding network requirements. The Triple-Speed and Dual-media functions

expansion for the on-going demand of Ethernet networks. The 10/100/1000Mbps auto-

fiber media. The up-link choice of 10, 100 or 1000Mb fiber on Port# 1 enables easy

cable plant and equipment. The Magnum CSG14Ps fit very well in high temperature

Red- “Premium rated (outdoor)”), the multifunctional, multi-media and multi-

2.5 Applications for CSG14 Series Converter Switches

Page 45 of the GarrettCom CSG14U user manual — 2.5 Applications for CSG14 Series Converter Switches
Page 45 · click to enlarge
Page 45

copper, and also easily solve long distance requirements. The ruggedness of the CSG14P’s

aluminum case and the high reliability of the design compliment the temperature-controlled

provide a very economical high bandwidth solution at each cable user access point of

packaging to provide an exceptional Ethernet product.

Page 46 of the GarrettCom CSG14U user manual — 2.5 Applications for CSG14 Series Converter Switches
Page 46 · click to enlarge
Page 46
GarrettCom CSG14U — 2.5 Applications for CSG14 Series Converter Switches diagram (page 46)
Fig. 13 · 2.5 Applications for CSG14 Series Converter Switches
Example 1Indoor Office CSG14H
Page 47 of the GarrettCom CSG14U user manual — 2.5 Applications for CSG14 Series Converter Switches
Page 47 · click to enlarge
Page 47

Magnum CSG14 Converter Switch. Additional functionality includes the ability to transfer

Example 1In this example, the indoor office location is a Data Mining function with an

ongoing demand to grow the network. This need can be easily met using the economical

data across large distances with multi- or single–mode fiber while securing the LAN from

EMI and wire-tapping.

Page 48 of the GarrettCom CSG14U user manual — 2.5 Applications for CSG14 Series Converter Switches
Page 48 · click to enlarge
Page 48
GarrettCom CSG14U — 2.5 Applications for CSG14 Series Converter Switches diagram (page 48)
Fig. 14 · 2.5 Applications for CSG14 Series Converter Switches
Example 2CSG14H
Page 49 of the GarrettCom CSG14U user manual — 2.5 Applications for CSG14 Series Converter Switches
Page 49 · click to enlarge
Page 49
Example 2In this application, where in expanding an industrial network environment, the

hardened version of Magnum CSG14H is typically used. . The Fiber port on the converter

efficient cooling techniques and having no openings for dirt to enter, the CSG14 Series

encountered in this edge of network application. Built with high-grade components,

new PLC units are deployed on an existing network and each needs one (or two for

redundancy) Ethernet ports to carry status and control data to the control center the

switches is ideal for secure data communications over long distances that may be

Converter Switches provide the very effective solution for this need.

Page 50 of the GarrettCom CSG14U user manual — 2.5 Applications for CSG14 Series Converter Switches
Page 50 · click to enlarge
Page 50
GarrettCom CSG14U — 2.5 Applications for CSG14 Series Converter Switches diagram (page 50)
Fig. 15 · 2.5 Applications for CSG14 Series Converter Switches
Example 3CSG14P
Page 51 of the GarrettCom CSG14U user manual — 2.5 Applications for CSG14 Series Converter Switches
Page 51 · click to enlarge
Page 51

motion detectors or will act as a test port for maintenance personnel with up-link for access

cameras may be spread out over many miles in temperature un-controlled locations and

with pan, tilt and zoom (PTZ) controlled through an Ethernet copper port .The premium

Converter Switches are ideally suited to providing copper to fiber media conversion for

controlled cabinets and allowing a full range of AC and DC power options. The second

copper port at the remote location provides access for other Ethernet equipment such as

Example 3In this example, the Magnum CSG14P Premium Converter Switches are

secure long distance (2-70km) communication while being installed in temperature un-

deployed to serve as a secure corporate or transportation surveillance system. CCTV

to a central LAN and central file servers.

Page 52 of the GarrettCom CSG14U user manual — 2.5 Applications for CSG14 Series Converter Switches
Page 52 · click to enlarge
Page 52
GarrettCom CSG14U — 2.5 Applications for CSG14 Series Converter Switches diagram (page 52)
Fig. 16 · 2.5 Applications for CSG14 Series Converter Switches

easily extended or expanded as conditions

capability that enables connecting many

disparate devices in a fiber-media string,

and devices needing network attachment

Example 4CSG14U “Drop & Add”

covering even very long distances (for

backbone LAN with a “Drop & Add”

example, a pipeline). Such designs are

In this example, Magnum CSG14U

Converter Switches form a gigabit

change over time.

capability

Page 53 of the GarrettCom CSG14U user manual — 3.0 INSTALLATION
Page 53 · click to enlarge
Page 53
GarrettCom CSG14U — 3.0 INSTALLATION diagram (page 53)
Fig. 17

This section describes the installation of the Magnum CSG14 Series Converter

3.0 INSTALLATION

options and media connection.

care of network traffic and can

mountings and power supply

3.1 Locating the Converter Switch Unit

economical tool to expand an

duplex mode. The store and

forward switch easily takes

Series Switches operate in

be used as a useful,

existing network.

Switches, including location; · All the CSG14 · transparent half-and full-

Page 54 of the GarrettCom CSG14U user manual — 3.0 INSTALLATION
Page 54 · click to enlarge
Page 54

The compact and lightweight design of the Magnum CSG14 Series allows it to be

shelf. Alternatively, metal mounting clips and screws are included for a rugged and secure

procedure. The installation location is dependent upon the physical layout of the Ethernet

easily installed in almost any location. A Velcro strip may be used for mounting the unit

network and associated cabling. Make sure the unit is installed in a location that is easily

on a vertical surface such as a wall or cabinet, or for securing the unit on a table-top or

accessible to an AC power outlet or the appropriate DC source and where cooling is not

Installation of the Magnum CSG14 Series Converter Switches is a simple

inhibited. The green Power (PWR) LED must turn ON when power is applied.

mounting in any orientation.

Page 55 of the GarrettCom CSG14U user manual — 3.0 INSTALLATION
Page 55 · click to enlarge
Page 55
GarrettCom CSG14U — 3.0 INSTALLATION diagram (page 55)
Fig. 18

mount tray is available, the MC14-TRAY. The Converter Switches are mounted with the

DC power jack in the back, with the fiber and the RJ-45 connectors in the front. Any mix

3.2 MC14-TRAY for Rack Mounting of CSG14 Series Switches For 19” rack-mounting of Magnum CSG14 Series Converter Switches, a rack-

of the Converter Switches and/or Media Converters may be placed on a tray, up to a

mounting spaces of the MC14-

Magnum products and will not

19” rack-mount tray will hold a few (three to eight) CSG14

maximum of 16 units. (The

TRAY are specific to the

permit other models to be

properly mounted).

installation, the MC14-TRAY, · Series Converter Switches, · In a typical

Page 56 of the GarrettCom CSG14U user manual — 3.0 INSTALLATION
Page 56 · click to enlarge
Page 56
GarrettCom CSG14U — 3.0 INSTALLATION diagram (page 56)
Fig. 19

with their power supplies plugged into power strips (not included) in the rear area of the

tray. Metal mounting screws in the bottom-front hold the Converter Switches firmly in

place. The beveled-top edge of the units permits the LEDs of each unit to be viewed for

operational status, even when the units are very close together.

The MC14-TR+ PS9 and

MC14-TR+PS9X2 are other options

1000Mbps Converter Switches and Media Converters together in a 19”

universal AC power supply rated at

3.3 MC14-TR+PS9 and MC14- TR+PS9X2 for Rack Mounting

55 watts at 50°C ambient, 9 VDC

Magnum 10Mbps, 100Mbps and

rack-mount tray. These models

for rack mounting the mix of

come with a built-in common

Page 57 of the GarrettCom CSG14U user manual — 3.0 INSTALLATION
Page 57 · click to enlarge
Page 57

regulated output, and supporting up to 10 Switches for MC14-TR+PS9 and 16 units CSG14

Series for MC14-TR+PS9X2. The MC14-TR+PS9X2 Model has two groups of eight units

securing them in the tray and enabling separate removal for service. The dual LEDs permit

TR+PS9, 19” rack-mount tray, holding a few Converter Switches, each with their power

input plugged into the built-in common AC power supply in the rear area of the tray. (PS

Metal mounting screws in the bottom-front hold each of the media converters

per power supply. The power supplies have auto-ranging AC input for use worldwide.

The side-view below is an example of an installation of the model MC14-

units that come with the MC’s are not used).

viewing of Switch status from any angle.

Page 58 of the GarrettCom CSG14U user manual — 3.0 INSTALLATION
Page 58 · click to enlarge
Page 58

The Magnum CSG14 models with “HR” have 24VDC power, and have the DIN-

It comes with four screws to attach the bracket to the MC unit. The rail clip is

spring-loaded with a pull-up latch at the top for easy “snap-on” attachment and removal.

GarrettCom CSG14U — 3.0 INSTALLATION diagram (page 58)
Fig. 20

Rail-MC2 bracket included and assembled with the MC unit at the factory.

A Magnum CSG14H is shown

alongside the DIN-Rail-MC2 bracket

hardware is optional and needs to be ordered as

a separate item, e.g. Model #DIN-RAIL-MC2.

environments, are also available for DIN-Rail

CSG14PR Converter Switches, designed for

mounting in an enclosure having DIN Rails.

use in “Factory Floor” Industrial Ethernet

The metal DIN-Rail mounting

3.4 DIN-Rail mounting option The Magnum CSG14HR and

Page 59 of the GarrettCom CSG14U user manual — 12VDC 24VDC -48VDC
Page 59 · click to enlarge
Page 59

external AC power supply. Magnum CSG14 Series require a 12VDC input power supply.

withstand higher temperature environments, and provide the DC power choices to the user

The 12V DC power input has a plug of 2.5mm, center +ve , with 6 ft. cord. All

Magnum CSG14 Series Switches are power-efficient and can work with an

the AC power supply info detail is provided in Technical Specifications Section 1.1.

The CSG14 Series are designed to be used with UL listed Class II power

supplies. The CSG14H and CSG14P converter switches provide reliable operation,

The extended temperature (H and P) versions are used for heavy-duty industrial

12VDC 24VDC -48VDC

3.5 Power Requirements for CSG14 Series Switches

to deploy in uncontrolled temperature environments.

applications.

Page 60 of the GarrettCom CSG14U user manual — 12VDC 24VDC -48VDC
Page 60 · click to enlarge
Page 60

The Direct DC (Internal) 12V DC (8 – 15V DC) has a built-in terminal block for

only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like).

3.6 Powering the CSG14 with 12V, 24V or –48VDC power input Each Magnum CSG14H/CSG14P-Series is reliably equipped with an internal DC

+, -, ground. The 9V DC jack is also present. Detailed information about the 12 VDC, the

Various models of DC power type and extended ambient temperature power supplies are

power supply, and has built-in screw terminals for secure attachment of the power leads.

Three models support a range of power input types. The three model choices are for use

with 12VDC, 24VDC or -48VDC power. DC power input may be chosen for high-

24V DC and the –48V DC is provided in the Technical Specifications Section 1.1.

available. Specify the power supply needed on your order.

availability.

Page 61 of the GarrettCom CSG14U user manual — 18 – 36V DC (24V DC)
Page 61 · click to enlarge
Page 61
GarrettCom CSG14U — 36 – 60V DC (-48V DC) diagram (page 61)
Fig. 21
GarrettCom CSG14U — 36 – 60V DC (-48V DC) diagram (page 61)
Fig. 22

temperature uncontrolled environments, rated at

–40`C to +75`C. If indoors, the DC jack is also

36 – 60V DC (-48V DC)

The extended temperature capability

Input Voltage8 - 15V DC (12V DC)

18 – 36V DC (24V DC)

GNDTerminal for “earth” or ground wire

of the DC-powered CSG14P’s can go into

present and optionally can be used with an

DC Power Terminals“+”, “-”, gnd

connection to the CSG14H chassis

external AC power supply.

Page 62 of the GarrettCom CSG14U user manual — 36 – 60V DC (-48V DC)
Page 62 · click to enlarge
Page 62
GarrettCom CSG14U — 36 – 60V DC (-48V DC) diagram (page 62)
Fig. 23
GarrettCom CSG14U — 36 – 60V DC (-48V DC) diagram (page 62)
Fig. 24

Power Consumption: 4 watts typical, 5 watts max.

0.4 amp max.(24V DC)

0.2 amp max.(-48V DC)

3.7 CSG14 Series, DC-powered, -48, 24 and 12VDC Installation This section describes the proper

12VDC leads) to the DC power terminal block on the Magnum CSG14H hardened media

connection of the -48VDC leads (or 24VDC,

Input current0.8 amp.(12V DC)

terminal block on the Magnum CSG14H is

located on the left side of the unit and is

converter (as shown in Figure). The DC

Page 63 of the GarrettCom CSG14U user manual — 36 – 60V DC (-48V DC)
Page 63 · click to enlarge
Page 63

positive (+) and negative (-), and they are floating inside the unit so that the user if desired

The connection procedure is straightforward. Simply insert the DC leads to the

and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead

equipped with three (3) screw-down lead posts. The power terminals are identified as

(GND) optional; it connects to the CSG14H chassis. Ensure that each lead is securely

CSG14H’s power terminals, positive (+) and negative (-) screws. The use of Ground

may ground either of the terminals. The chassis is “earth” or ground (GND).

will connect to the post-labeled “+ve” and the rest to the “-ve”.

When power is applied, the green PWR LED will illuminate.

tightened from the top, as shown here.

The GND can be hooked up at the last.

Page 64 of the GarrettCom CSG14U user manual — 36 – 60V DC (-48V DC)
Page 64 · click to enlarge
Page 64

used when making 1000BASE-T connections. When the ports are used as 10BASE-T ports,

cabling is 100 meters (328 ft). For fiber port 10BASE-FL, 100BASE-FX or 1000BASE-SX

types i.e. fiber and copper (RJ-45) types, run at 1000BASE-T, 100BASE-TX, 10BASE-T

9/125 microns cabling should be used. Fiber cabling supports much longer cable distance and higher bandwidths as compared to copper wiring.

3.8 Connecting Ethernet Media The Magnum CSG14 Series Converter Switch can be connected to two media

and 1000BASE-SX/LX/ZX, 100BASE-FX, or 10BASE-FL. CAT 5E cables should be

multi-mode, 50/125 or 62.5/125 microns cabling can be used, whereas for single-mode,

CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair

Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45

Twisted Pair (CAT 5) 100BASE-TX RJ-45

Media IEEE Standard Connector

Twisted pair (CAT5E or CAT6) 1000BASE-T RJ-45

Fiber (Multi-mode) 10BASE-FL SC

Page 65 of the GarrettCom CSG14U user manual — 36 – 60V DC (-48V DC)
Page 65 · click to enlarge
Page 65

10Mbps, 100Mbps and 1000Mbps) be used whenever possible in order to provide flexibility in a mixed-speed network, since CSG14 Series switch ports are auto-

or 1000BASE-T twisted pair segment to the RJ-45 port. The procedure is the same for both

sensing for either 10,100 or 1000Mbps. Note that the auto-cross function does

The following procedure describes how to connect a 10BASE-T, 100BASE-TX

3.8.1 Connecting Twisted Pair (RJ-45, CAT 3, CAT 5 or CAT 6, Unshielded or

Fiber (Single-mode) 100BASE-FX SC, LC

Fiber (Multi-mode, Single-mode) 1000BASE-SX SC, LC

not operate, if the port is fixed or not supporting auto-negotiation.

Fiber (Multi-mode) 100BASE-FX SC

Fiber (Single-mode) 1000BASE-LX/ZX LC

unshielded and shielded twisted pair cables.

Shielded)

Page 66 of the GarrettCom CSG14U user manual — 36 – 60V DC (-48V DC)
Page 66 · click to enlarge
Page 66

does not help, ensure that the cable is connected properly and that the device on the

The following procedure applies to installations using LC-type fiber connectors,

1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is
2. Connect the other end of the cable to the corresponding device. 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established. If this
4. For Port # 1 or 1SW, if the LINK LED is not illuminated, move the switch which has a cross-over or up-link for linking to another hub or Switch.

simply snap on the two square male connectors into the LC female jacks of the

i.e., using LC single-mode. While connecting fiber media to LC connectors,

3.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)”

shielded, either unshielded or shielded cables and wiring may be used.

Fiber connector until it clicks and secures.

other end is powered and is not defective.

Page 67 of the GarrettCom CSG14U user manual — 36 – 60V DC (-48V DC)
Page 67 · click to enlarge
Page 67

Grasp the SFP module by your thumb and forefinger. Insert the SFP into the SFP

The following procedure applies to installations using SC-type fiber connectors,

simply snap on the two square male connectors into the SC female jacks of the

connectors. Single-mode fiber cable has a smaller diameter than multi-mode

i.e., using multi-mode SC. While connecting fiber media to SC connectors,

slot. Apply a light pressure to the SFP until the device clicks and locks into

fiber cable (9/125 microns for single-mode, 50/125 or 62.5/125 microns for

multi-mode where xx/xx are the diameters of the core and the core plus the

When using single-mode fiber cable, be sure to use single-mode fiber port

cladding respectively). Single-mode fiber allows full bandwidth at longer

The same procedures as for single-mode fiber apply to multi-mode fiber

3.8.4 Installing LC-type SFP module,“Small Form Pluggable (SFP)”

connectors. Follow the steps listed in Section 3.8.3 above.

distances, about 70km with the single-mode LC.

3.8.3 Connecting Fiber Optic SC-type, "Snap-In"

position. Now connect your LC connectors.

Fiber connector until it clicks and secures.

3.8.5 Connecting Single-Mode Fiber Optic

Page 68 of the GarrettCom CSG14U user manual — 36 – 60V DC (-48V DC)
Page 68 · click to enlarge
Page 68

Siemens’) web sites and catalogs to provide guidance to network designers and installers

Receiver Sensitivity and Transmitter Power are the parameters necessary to

where the “Cable Loss” for 62.5/125 and 50/125μm (m.m.) is 2.8 dB/km,

compute the power budget. To calculate the power budget of different fiber media

The following data has been collected from component manufacturer’s (HP’s, and

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

installations using Magnum products, the following equations should be used:

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

3.8.6 Power Budget Calculations for CSG14 Series, Fiber Media

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

OPB (Optical Power Budget) = PT(min) - PR(min)

Page 69 of the GarrettCom CSG14U user manual — CSG14-
Page 69 · click to enlarge
Page 69
GarrettCom CSG14U — CSG14- diagram (page 69)
Fig. 25

mode 0.55 850 62.5/125 50/125 -9.5 -17 5.5 2 12.5 4

-mode 10 1310 9/125 -9.5 -20 8.5 17 10.5 21

-mode 25 1310 9/125 -4.0 -21 15 37.5 17.5 43

-mode 40 1550 9/125 -4.0 -21 15 60 17.5 70

-mode 70 1550 9/125 -3.0 -23 18 90 20.5 102

SX 1000Mb SX Multi-

Std.

CSG14-

CSG14-

CSG14-

CSG14-

ZX40

CSG14-

ZX70

Show 8 more labels / short text on this page
1000Mb LX Single · 1000Mb LX Single · 1000Mb ZX Single · Speed, · 1000Mb ZX · Fiber · Port · Module
Page 70 of the GarrettCom CSG14U user manual — CSG14-
Page 70 · click to enlarge
Page 70

NIC to the CSG14 Series, it may be necessary to reload the NIC drivers on the user device

100BASE-TX). When 1000Mb operation is agreed and in use, the Gb LED is illuminated steady ON and is OFF, for 10 or 100Mbps traffic.

* Note: The use of either multi-mode or single-mode fiber to operate at 1000Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following

Fast Link Pulse (FLP) coding for the 1000BASE-T signaling system. When connecting a

  • The worst-case OPB of the fiber link must be greater than the fiber cable’s

The copper ports of Magnum CSG14 Series Converter Switches will function

properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the

  • The 1000Mb fiber segment must operate in full-duplex (FDX) mode, and

if the NIC has been communicating with a protocol other than 1000BASE-T (such as

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

3.8.7 Connections to NICs which support Auto-Negotiation

passive Attenuation.

factors are both applied:

Page 71 of the GarrettCom CSG14U user manual — 4.0 OPERATION
Page 71 · click to enlarge
Page 71

speed, and auto cross for plug polarity. (See Section 2.2). When the connected device is 10

configuring to be done at installation or for maintenance. The only hardware configuration

users can “communicate” with 100Mbps users as well as other 10 Mbps users through the

settings are user options for port #2, to configure it FF/AN. The internal functions of both

4.1 Triple-Speed Functionality, and Switching The Magnum CSG14 Series Converter Switches provide three switched ports.

Mbps, the CSG14s obey all the rules of 10 Mbps Ethernet configurations. The 10 Mbps

Magnum CSG14 Series units are plug-and-play devices. There is no software

The switched RJ-45 ports are full- or half-duplex auto-sensing for mode and

switch. Similarly, the 100Mbps traffic obeys the rules of 100Mbps Ethernet, and can

The architecture supports a triple speed-switching environment, with standard auto-

communicate with 10 Mb and 100Mb users.

4.0 OPERATION

negotiation capability.

are described below.

Page 72 of the GarrettCom CSG14U user manual — 4.0 OPERATION
Page 72 · click to enlarge
Page 72

either filter or to forward the packet. Packets whose source and destination addresses lie on

the same port segment, will be filtered, constraining them to one port and relieving the rest

Each time a packet arrives on one of the switched ports, the decision is taken to

ports where it is not needed. Packets needed for maintaining the operation of the network

eliminates bad packets and enables peak performance to be achieved when there is heavy

of the network from processing them. A packet whose destination address is on another

port segment will be forwarded to the appropriate port, and will not be sent to the other

(such as occasional multi-cast packets) are forwarded to all ports. The Magnum CSG14

nodes are added or removed or moved from one segment to another, the CSG14 Series

addresses, and are suitable for use in large networks. They are self-learning, so that as

The Magnum CSG14 Series units have address table capacity of 1K node

Series Converter Switches operate in the store-and-forward switching mode, which

Switching, Filtering and Forwarding

traffic on the network.

Switching, Address Learning

Page 73 of the GarrettCom CSG14U user manual — 4.0 OPERATION
Page 73 · click to enlarge
Page 73

An address-aging algorithm causes least-used addresses to fall out in favor of new

connecting the CSG14’s to other unmanaged switches, legacy hubs, managed switches,

where the switch manager fixes the port settings via software, and the result of the auto-

negotiation is changed in the managed switch by the manager commands. In such cases,

The RJ-45 ports support auto cross (MDI or MDIX) in the auto-negotiation

media-converters etc. Please note that there can be conditions with managed switches

the 10/100/1000 speed or the F/H mode may be affected, but auto-cross in the CSG14

advertises its capability for 10, 100 or 1000Mbps speed and F/H duplex mode, and the

mode according to the IEEE 802.3z standard. No crossover cables are needed when

When an RJ-45 cable connection is made, and each time LINK is enabled,

frequently used addresses. To reset the address buffer, cycle power down-and-up.

auto-negotiation takes place (except for legacy products, which do not have auto-

negotiation and which go to the default state accordingly). The Magnum Switch

Switches will still work. The auto cross function cannot be disabled.

4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing

switch automatically keeps up with node locations.

Page 74 of the GarrettCom CSG14U user manual — 4.0 OPERATION
Page 74 · click to enlarge
Page 74

segment or a loss of power occurs in the unit or remote device. The Link ports

turn off in the event connectivity is lost between the ends of the twisted pair

device at the other end of the cable should similarly advertise / respond. Both sides will

agree to the speed and mode to be used per the IEEE 802.3z standard. Depending upon

LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will

the devices connected, this will result in agreement to operate at 10Mbps, 100Mbps or

Gb Steady ON for 1000Mb speed, OFF for 100Mb or 10Mb speed per port

are also represented by LA1, LA2, and LA3. (Steady On or steady Off

PWR Illuminates GREEN to indicate power applied.

4.3 Dual LEDs, Top-front and in End with ports LED Description

1000Mbps speed, and full- or half-duplex mode.

indicates no Receive Activity).

Page 75 of the GarrettCom CSG14U user manual — 5.0 TROUBLESHOOTING
Page 75 · click to enlarge
Page 75

Switch is not performing as expected, do not attempt to repair the unit; instead contact your

10/100/1000 Mb/s Switches is a straightforward procedure (see INSTALLATION, Section

Should problems develop during installation or operation, this section is intended

to help locate, identify and correct these types of problems. Please follow the suggestions

All Magnum products are designed to provide reliability and consistently high

procedures described in this section or if the Magnum CSG14 Series 10/100/1000 Mb/s

performance in all network environments. The installation of Magnum CSG14 Series

listed below prior to contacting your supplier. However, if you are unsure of the

3.0); the operation is also straightforward and is discussed in Section 4.

supplier for assistance or contact GarrettCom Customer Support.

5.0 TROUBLESHOOTING

Page 76 of the GarrettCom CSG14U user manual — 5.0 TROUBLESHOOTING
Page 76 · click to enlarge
Page 76

into a functioning electrical outlet. Use the PWR LEDs to verify each unit is

the problem device is replaced with a known good device. Verify whether or

5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back

to the Installation Section of the applicable chapter of this manual. Also

2. Check the cables and connectors to ensure that they have been properly

impaired during installation. (About 90% of network downtime can be

3. Make sure that an AC power cord is properly attached to each Magnum

CSG14 Series 10/100/1000 Mb/s switch product, it is recommended that

connected and the cables/wires have not been crimped or in some way

4. If the problem is isolated to a network device other than the Magnum

check to make sure that the various components of the network are

CSG14 Series unit. Be certain that the AC power cord is plugged

attributed to wiring and connector problems.)

receiving power.

interoperable.

Page 77 of the GarrettCom CSG14U user manual — 5.0 TROUBLESHOOTING
Page 77 · click to enlarge
Page 77
5. If the problem continues after completing Step 4 above, contact your supplier

not the problem is corrected. If not, go to Step 5 below. If the problem is

d. Any particular application that, when used, appears to create the problem;

of the Magnum CSG14 Series 10/100/1000 Mb/s Switch unit or if

1. A complete description of the problem, including the following points:

corrected, the Magnum CSG14 Series Switch and its associated

unknown, contact GarrettCom, Inc by fax, phone or email

Please be prepared to provide the following information.

(support@garrettcom.com) for assistance.

c. The components involved in the problem;

a. The nature and duration of the problem;

b. Situations when the problem occurs;

cables are functioning properly.

5.2 When Calling for Assistance

Page 78 of the GarrettCom CSG14U user manual — 5.0 TROUBLESHOOTING
Page 78 · click to enlarge
Page 78
2. An accurate list of GarrettCom product model(s)involved, with serial number(s).

including convenient computers, workstations, terminals and printers; plus, the

3. It is useful to include other network equipment models and related hardware,
4. A record of changes that have been made to your network configuration prior

to the occurrence of the problem. Any changes to system administration

Include the date(s) that you purchased the products from your supplier.

procedures should all be noted in this record.

various network media types being used.

Page 79 of the GarrettCom CSG14U user manual — 5.0 TROUBLESHOOTING
Page 79 · click to enlarge
Page 79

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

5.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization

(RMA) number. To obtain an RMA number, please use this URL -

Failure symptoms, including a full description of the problem.

Please have the following information readily available:

Name and phone number of your contact person.

Packing List Number (or Sales Order Number)

Name of your company / institution

Serial Number (or Invoice Number)

Your shipping address · Date of installation · Product name

Page 80 of the GarrettCom CSG14U user manual — 5.0 TROUBLESHOOTING
Page 80 · click to enlarge
Page 80

GarrettCom will carefully test and evaluate all returned products, will repair products that

are under warranty at no charge, and will return the warranty-repaired units to the sender

details). However, if GarrettCom cannot duplicate the problem or condition causing the

GarrettCom reserves the right to charge for the testing of non-defective units

under warranty. Testing and repair of product that is not under warranty will result in a

with shipping charges prepaid (see Warranty Information, Appendix A, for complete

No Problem Found.

return, the unit will be returned as:

customer (user) charge.

Page 81 of the GarrettCom CSG14U user manual — 5.0 TROUBLESHOOTING
Page 81 · click to enlarge
Page 81
1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet

Should you need to ship the unit back to GarrettCom, please follow these instructions:

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

or bag for shipping protection. (You may retain all connectors and this

3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to: GarrettCom, Inc.

This material may cause electro-static shock damage to the unit.

47823 Westinghouse Drive Fremont, CA 94539

Attn.: Customer Service

5.4 Shipping and Packaging Information

Installation Guide.)

Page 82 of the GarrettCom CSG14U user manual — APPENDIX A: WARRANTY INFORMATION
Page 82 · click to enlarge
Page 82

During this warranty period, GarrettCom will repair or, at its option, replace components in

This warranty will not be effective if, in the opinion of GarrettCom, GarrettCom

has damaged by misuse, misapplication, or as a result of service or modification other than

Please complete the warranty card as this acts as a product registration, and mail

GarrettCom, Inc. warrants its products to be free from defects in materials and

the product. GarrettCom reserves the right to make a charge for handling and inspecting

workmanship for a period of three (3) years from the date of shipment by GarrettCom.

the products that prove to be defective at no charge other than shipping and handling,

any product returned for warranty repair which turns out not to be faulty.

provided that the product is returned pre-paid to GarrettCom.

APPENDIX A: WARRANTY INFORMATION

it to GarrettCom within two weeks of your purchase.

Ask about the GarrettCom CSG14U

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom CSG14U

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom CSG14U manual PDF

82 pages·584 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…