EN
GarrettCom logo
Official user manual

GarrettCom CSG14

77 pages·573 KB·Switch·PDF·ENDEFRITNLJA
GarrettCom CSG14
Table of Contents 80 sections Magnum CSG14 Gigabit Converter Switches · Installation and User Guide · Magnum ™ CSG14 Series Gigabit Converter Switch · Radio Frequency Interference Statement · … ShowHide
Magnum CSG14 Gigabit Converter Switchesp.1Installation and User Guidep.1Magnum ™ CSG14 Series Gigabit Converter Switchp.2Radio Frequency Interference Statementp.4Federal Communications Commissionp.4Email: [email protected]p.547823 Westinghouse Drive Fremont, CA 94539p.5Phone (510) 438-9071p.5Fax (510) 438-9072p.5Contacting GarrettCom, Incp.53.6 Powering the CSG14H and CSG14P (DC internal) .......................... 45p.73.7 CSG14H and P Series , DC-powered, Installation ............................. 47p.73.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)” ... 51p.73.8.3 Connecting Fiber Optic SC-type, "Snap-In" .............................. 51p.73.8.4 Connecting Single-Mode Fiber Optic ........................................ 52p.73.8.5 Power Budget Calculations for CSG14 Series, Fiber Media ..... 52p.73.8.6 Connections to NICs which support Auto-Neg RJ-45 ports ...... 55p.74.1 Triple-Speed Functionality, and Switching ....................................... 56p.74.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing ................ 58p.74.3 Dual LEDs, Front-panel and Side-panel ............................................ 60p.75.3 Return Material Authorization (RMA) Procedure ............................. 65p.7APPENDIX A: WARRANTY INFORMATION ......................................... 69p.8Revisionsp.8Packet-Processing Between Domainsp.9Auto-learning: 1K-address tablep.91.1 Technical Specificationsp.91.0 SPECIFICATIONSp.9Ports Performancep.9Network Standardsp.9Cold Start:p.11Operating Environmentp.11Cooling Method:p.12Packaging:p.12AC POWER SUPPLY (using an external power adapter):p.13Factory Floor (H) Ratings (-25 to 60°C)p.13POWER SUPPLYp.13Temperature un-controlled Premium (P) Ratings (-40 to 75°C)p.14Direct DC POWER SUPPLY: built-in terminal blockp.14for +, -, ground along with 12VDC jackp.14LED Indicators (Two sets) top-front and end with portsp.17Mounting optionsp.17Top-Front:p.17Agency Approvals and Standards Compliance:p.181.2 Summary of models and descriptions:p.192.1 Inspecting the Package and the Productp.222.0 INTRODUCTIONp.222.2 Product Descriptionp.23CSG14H with 1000Mb SC connectorp.27Fig 2.2ap.272.3 Frame Buffering and Latencyp.30Ethernet LANsp.34converterp.342.5 Applications for CSG14 Series Converter Switchesp.37LA3 LA2 LA1p.39PWR F/Hp.392 3 A FFp.39FH1p.39F/Hp.39LK/ACTp.39POWERp.39Example 2: CSG14Hp.41GARRETTp.41UPLINK 3 4 5 6 7 8 1SWp.432SWp.43F H = Xp.43Secure attachment ofp.45clips for panel -p.453.1 Locating the Converter Switch Unitp.453.0 INSTALLATIONp.453.3 MC14-TR+PS9 and MC14-TR+PS9X2 for Rack Mounting Media Convertersp.48A Magnum CSG14H is shownp.503.5 Power Requirements, Power Supply Types for CSG14 Series Switchesp.5112VDC 24VDC -48VDCp.5236 – 60V DC (-48V DC)p.5418 – 36V DC (24V DC)p.543.7 CSG14H and P Series, DC-powered, -48VDC, 24VDC and 12VDC Installationp.553.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded orp.58Shielded)p.583.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)”p.593.8.3 Connecting Fiber Optic SC-type, "Snap-In"p.59
Page 1 of the GarrettCom CSG14 user manual — Installation and User Guide
Page 1 · click to enlarge
Page 1

Magnum CSG14 Gigabit Converter Switches

GarrettCom CSG14 — Magnum CSG14 Gigabit Converter Switches diagram (page 1)
Fig. 1 · Magnum CSG14 Gigabit Converter Switches

Installation and User Guide

GarrettCom CSG14 — Installation and User Guide diagram (page 1)
Fig. 2 · Installation and User Guide
Page 2 of the GarrettCom CSG14 user manual — Installation and User Guide
Page 2 · click to enlarge
Page 2

Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.

Magnum ™ CSG14 Series Gigabit Converter Switch

GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch, Converter

Installation and User Guide

UL is a registered trademark of Underwriters Laboratories

Part #84-00102Z Rev. A

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

Trademarks

Page 3 of the GarrettCom CSG14 user manual — Magnum ™ CSG14 Series Gigabit Converter Switch
Page 3 · click to enlarge
Page 3

Switches contain no user serviceable parts. Attempted service by unauthorized

Copyright © 2008 GarrettCom, Inc. All rights reserved. No part of this publication may

experienced with Magnum CSG14 10/100/1000 Mb/s Converter Switch

be reproduced without prior written permission from GarrettCom, Inc.

personnel shall render all warranties null and void. If problems are

products, consult Section 5, Troubleshooting, of this User Guide.

Printed in the United States of America

Page 4 of the GarrettCom CSG14 user manual — Radio Frequency Interference Statement
Page 4 · click to enlarge
Page 4

This equipment generates, uses and can radiate frequency energy and if not

installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested and

found to comply with the limits for a Class A computing device in accordance with the

specifications in Subpart J of Part 15 of FCC rules, which are designed to provide

reasonable protection against such interference when operated in a commercial

environment. Operation of this equipment in a residential area is likely to cause

interference, in which case the user, at his/her own expense, will be required to take

Radio Frequency Interference Statement

Federal Communications Commission

whatever measures may be required to correct the interference.

Page 5 of the GarrettCom CSG14 user manual — Contacting GarrettCom, Inc
Page 5 · click to enlarge
Page 5

Please use the mailing address, phone and fax numbers and email address listed below:

Websitehttp://www.GarrettCom.com

Email: [email protected]

47823 Westinghouse Drive Fremont, CA 94539

GarrettCom, Inc.

Phone (510) 438-9071

Fax (510) 438-9072

Contacting GarrettCom, Inc

Page 6 of the GarrettCom CSG14 user manual — Email: support@garrettcom.com
Page 6 · click to enlarge
Page 6
Page 6 of the GarrettCom CSG14 user manual — Email: support@garrettcom.com
Page 7 of the GarrettCom CSG14 user manual — 3.6 Powering the CSG14H and CSG14P (DC internal) .......................... 45
Page 7 · click to enlarge
Page 7

3.6 Powering the CSG14H and CSG14P (DC internal) 45

3.7 CSG14H and P Series , DC-powered, Installation ............................. 47

3.8 Connecting Ethernet Media ............................................................... 48

3.8.1 Connecting Twisted Pair ............................................................ 50

3.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)” ... 51

3.8.3 Connecting Fiber Optic SC-type, "Snap-In" .............................. 51

3.8.4 Connecting Single-Mode Fiber Optic ........................................ 52

3.8.5 Power Budget Calculations for CSG14 Series, Fiber Media ..... 52

3.8.6 Connections to NICs which support Auto-Neg RJ-45 ports ...... 55

4.0 OPERATION ....................................................................................... 56

4.1 Triple-Speed Functionality, and Switching ....................................... 56

4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing ................ 58

4.3 Dual LEDs, Front-panel and Side-panel ............................................ 60

5.0 TROUBLESHOOTING ...................................................................... 61

5.1 Before Calling for Assistance ............................................................ 62

5.2 When Calling for Assistance ............................................................. 64

5.3 Return Material Authorization (RMA) Procedure ............................. 65

Page 8 of the GarrettCom CSG14 user manual — Revisions
Page 8 · click to enlarge
Page 8

5.4 Shipping and Packaging Information 67

APPENDIX A: WARRANTY INFORMATION ......................................... 69

Rev A 05/08Initial release of this user manual for CSG14 Converter Switches

GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or

model offerings without notice.

Revisions

Page 9 of the GarrettCom CSG14 user manual — Auto-learning: 1K-address table
Page 9 · click to enlarge
Page 9

Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.

Filter and Forward Rate from 1000Mbps ports: 1,488,000 pps max.

Filter and Forward Rate from 100Mbps ports: 148,800 pps max.

1000Mb: Ethernet IEEE 802.3ab and 802.3z 1000Base-T, -SX, -LX and -ZX 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3z

Data Rate10Mbps, 100Mbps, 1000Mbps
Processing typeStore and Forward, non-blocking

Packet-Processing Between Domains

Address buffer age-out time: 300 sec.

Auto-learning: 1K-address table

1.1 Technical Specifications

1.0 SPECIFICATIONS

Ports Performance

Network Standards

Page 10 of the GarrettCom CSG14 user manual — Packet-Processing Between Domains
Page 10 · click to enlarge
Page 10

10BASE-T (Unshielded twisted pair) 100 m (328 ft) 10BASE-FL, Fiber optic 2 km (6,562 ft) 10BASE-FL, Single-mode Fiber optic 10 km (32,810ft)

100BASE-TX (CAT 5 UTP) 100 m (328 ft) 100BASE-FX, half-duplex: (multi-mode) 412 m (1350 ft) 100BASE-FX, full duplex: (multi-mode) 2 km (6,562 ft) 100BASE-FX, half-duplex: (single-mode) 412 m (1350 ft) 100BASE-FX, full duplex: (single-mode) 20 km (65,620 ft) 100BASE-FX, full duplex: (single-mode, long reach) 40 km (131,240 ft) 1000BASE-T (CAT5E OR HIGHER recommended) 100 m (328 ft) 1000BASE-SX, full duplex, multi-mode (62.5um) 220 m (722 ft) 1000BASE-SX, full duplex, multi-mode (50um) 550 m (1804 ft) 1000BASE-LX, full duplex, single-mode (9um) 5 km (16404 ft)

Latency (not including packet time): 100 to 10 Mbps: 5μs 10 to 100Mbps: 15μs Path Delay Value: 50 BT on all ports

Packet buffers memory64KB, dynamically shared on all domains

Maximum Ethernet Segment (or Domain) Lengths

Page 11 of the GarrettCom CSG14 user manual — Cold Start:
Page 11 · click to enlarge
Page 11

1000BASE-ZX, full duplex, single-mode (9um) >70 km (229,659 ft)

CSG14H: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL).

CSG14P: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL)

-40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests

-40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests

Altitude (All models)-200 to 50000ft. (-60 – 15,000 m)
Ambient Relative Humidity5% to 95% (non-condensing)
All models-40 º F to 212 º F (-40 º C to 100 º C)

Conformal Coating (optional) for humidity protection

Cold Start:

Operating Environment

Storage Temperature, · CSG14H to -20ºC · CSG14P to -40ºC

Page 12 of the GarrettCom CSG14 user manual — Packaging:
Page 12 · click to enlarge
Page 12

Convection on the CSG14 Series models. The hardened (H) factory floor and premium (P)

temperature un-controlled location models have closed cases to withstand dirt and use

special thermal techniques to transfer heat to the outside of the case for cooling.

3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x 2.5 cm)

Power supply, –Hd, and Hi5.8 oz (165g)
–Pd, and -Pi7.9 oz (225g)

Enclosure: Rugged sheet metal (Steel).

Dimensions of the Switch unit:

Weightall models: 4.6 oz. (130g);

Cooling Method:

altitude.

Packaging:

Page 13 of the GarrettCom CSG14 user manual — POWER SUPPLY
Page 13 · click to enlarge
Page 13

These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked

500mA). When connected to a 48 V centralized dc source these products shall be provided

All models have a (8-15) VDC output with 6ft long cord and a 2.5mm center +ve jack. The

“Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output

voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to

North America (-Hd) models. Hardened, factory floor temperature rated. Input: 6ft AC

power cord to IEC 320 connector on the 100-240vac 47-63Hz external power adapter.

power supplies are temperature rated to match the Converter Switch ratings.

AC POWER SUPPLY (using an external power adapter):

with a Listed 5A DC fuses in the supply circuit.

Factory Floor (H) Ratings (-25 to 60°C)

Output12vdc, 1.25Amps

POWER SUPPLY

Page 14 of the GarrettCom CSG14 user manual — for +, -, ground along with 12VDC jack
Page 14 · click to enlarge
Page 14

North America (-Pd) models. Outdoor temperature rated. Input: 6ft AC power cord to IEC

International (-Hi) models. Factory floor temperature rated. Input: IEC 320 connector on

GarrettCom CSG14 — Temperature un-controlled Premium (P) Ratings (-40 to 75°C) diagram (page 14)
Fig. 3 · Temperature un-controlled Premium (P) Ratings (-40 t…
GarrettCom CSG14 — Temperature un-controlled Premium (P) Ratings (-40 to 75°C) diagram (page 14)
Fig. 4 · Temperature un-controlled Premium (P) Ratings (-40 t…

the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord

Temperature un-controlled Premium (P) Ratings (-40 to 75°C)

external power adapter. Requires a user supplied power cord.

320 connector on the100-240vac 47-63Hz external power adapters.

Direct DC POWER SUPPLY: built-in terminal block

International (-Pi) models. Outdoor temperature rated.

InputIEC 320 connector on the 100-240vac 47-63Hz

12V DC internal (range of 8.0 to 15V DC).

for +, -, ground along with 12VDC jack

Output: 12vdc, 1.25Amps.

Output: 12vdc, 2Amps.

Output: 12vdc, 2Amps.

Page 15 of the GarrettCom CSG14 user manual — Temperature un-controlled Premium (P) Ratings (-40 to 75°C)
Page 15 · click to enlarge
Page 15
GarrettCom CSG14 — Temperature un-controlled Premium (P) Ratings (-40 to 75°C) diagram (page 15)
Fig. 5 · Temperature un-controlled Premium (P) Ratings (-40 t…

the DC terminal block. Power supply protection is provided by internal diodes.

24V DC internal (range of 18 to 36V DC).

-48V DC internal (range of 36 to 60V DC), -, ground.

Power Consumption: See Section 3.6.

Page 16 of the GarrettCom CSG14 user manual — Temperature un-controlled Premium (P) Ratings (-40 to 75°C)
Page 16 · click to enlarge
Page 16

They are shielded 8-pin female connectors for shielded (STP) and unshielded

One Fiber optic portThe CSG14 series is 1000Base-SX / -LX / -ZX with a

Two RJ-45 Ports: support 10/100/1000Mbps with auto cross (MDIX).

“fiber flavor” choice of multimode SC or SLC connectors

Fiber port default is FDX (Full-Duplex)

RJ45’s are triple-speed auto-negotiating

(UTP) Cat 3, 4, 5 cables.

Port Connectors:

Switches

Page 17 of the GarrettCom CSG14 user manual — Mounting options
Page 17 · click to enlarge
Page 17
LK/ACT per portSteady ON for LINK (LK) with no traffic, BLINKING for Activity
Fiber portLK/ACT: Steady ON for Link with no traffic, BLINKING for Activity
Gb per RJ45 portSteady ON for 1000Mbps; OFF for 100Mbps or 10Mb speed

Mean Time Between Failure (MTBF) – over15 years, Telcordia (Bellcore) Method

Rack-mount optionMC14-TRAY, see http://www.garrettcom.com/mc_tray.htm
10/100/1000Mb per portSteady ON for 100Mb, OFF for 10Mb, BLINKING for 1000Mb
DIN-Rail mounting optionModel # DIN-RAIL MC2 (see Section 3.4)

LED Indicators (Two sets) top-front and end with ports

Metal mounting clips for panel mounting: included

POWERSteady ON when power applied
POWERSteady ON when power applied

End with Ports:

Mounting options

Top-Front:

Page 18 of the GarrettCom CSG14 user manual — Agency Approvals and Standards Compliance:
Page 18 · click to enlarge
Page 18

UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A.

IEC61850 EMC and Operating Conditions Class C Power Substations

WarrantyThree years, return to factory Made in USA
P modelIEEE P1613 Env. Std for Electric Power Substations
P modelNEMA TS-2 and TEES for traffic control equipment
P modeldesigned for UL 2043 above-the-ceiling installation

Agency Approvals and Standards Compliance:

NEBS L3 and ETSI compliant.

Page 19 of the GarrettCom CSG14 user manual — 1.2 Summary of models and descriptions:
Page 19 · click to enlarge
Page 19

factory floor (-25 to 60C) using a direct DC ( 8-15VDC) and/or external

CSG14H-ff-Hd, Hi = Hardened (H), two 10/100/1000Mb RJ-45+ one 1000Mb Fiber port for

except AC hardened power supply is not included

but includes DIN-RAIL-MC2 mounting option.

except 24VDC power input replaces 12VDC.

except -48VDC power input replaces 24VDC

AC hardened power supply (included).

CSG14H-ff-24VDC = Same as CSG14H-12VDC model,

CSG14HR-ff-24VDC = Same as CSG14H-24VDC model,

CSG14H-ff-48VDC = Same as CSG14H-24VDC model,

CSG14H-ff-12VDC = Same as CSG14H model,

1.2 Summary of models and descriptions:

CSG14H (Hardened Model) for 1000Mb fiber

Page 20 of the GarrettCom CSG14 user manual — 1.2 Summary of models and descriptions:
Page 20 · click to enlarge
Page 20

CSG14P-ff-48VDC = Same as CSG14P-24VDC model, except -48VDC input replaces 24VDC.

CSG14P-ff-Pd, Pi = Premium (P), two 10/100/1000Mb RJ-45+ one 1000Mb Fiber port for un-

controlled(outdoor) (-40 to 75C) using direct DC (8-15VDC) and/or

CSG14P-ff-12VDC = Same as CSG14P-Pd, Pi, except AC Premium Power Supply is not

“ESX”= 1000Base-SX Extended1310nm multi-mode fiber optic with SC type connector, 2 km
“LX10”= 1000Base-LX-SLC1310nm multi-mode fiber optic with LC type connector, 10 km

“SX” = 1000Base-SX-SC: 850nm multi-mode fiber optic with SC type connector, 550 m.

external AC premium power supply (included).

but includes DIN-RAIL-MC2 mounting option.

except 24VDC power input replaces 12VDC.

The “ff” field is for selection of the desired “fiber flavor” as listed below.

CSG14P-ff-24VDC = Same as CSG14P-12VDC model,

CSG14PR-ff-24VDC = Same as CSG14P-24VDC model,

CSG14P (Premium Model) for 1000Mb fiber

included.

Fiber Port Connectors:

Page 21 of the GarrettCom CSG14 user manual — 1.2 Summary of models and descriptions:
Page 21 · click to enlarge
Page 21
“SFP-ESX”= 1000Base-SX Extended1310nm multi-mode fiber optic with SC type connector, 2 km

Other Tray configurations with power supplies and power cabling included - See Section 3.3

“LX25” = 1000Base-LX-SLC1310nm multi-mode fiber optic with LC type connector, 25 km
“ZX40” = 1000Base-ZX-SLC1550nm single-mode fiber optic with LC type connector, 40 km
“ZX70”= 1000Base-ZX-SLC1550nm single-mode fiber optic with LC type connector, 70 km

“SFP” = open SFP transceiver slot in the fiber position. (order SFP as a separate item)

DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one CSG14 Series Switch,

MC14-TRAY = 19” Rack-mount tray for 14-series Switch models, up to 16 units

Conformal Coating (for high humidity and “tropical” applications) - request quote.

“SFP-LX10”= 1000Base-LX-SLC1310nm single-mode SFP, 10 km
“SFP-LX25”= 1000Base-LX-SLC1310nm single-mode SFP, 25 km
“SFP-ZX40”= 1000Base-ZX-SLC1550nm single-mode SFP, 40 km
“SFP-ZX70”= 1000Base-ZX-SLC1550nm single-mode SFP, 70 km
“SFP-SX”= 1000Base-SX-SC850nm multi-mode SFP, 550 m

See Section 3.4

Accessories

Page 22 of the GarrettCom CSG14 user manual — 2.0 INTRODUCTION
Page 22 · click to enlarge
Page 22

This section describes CSG14 Series models, including appearance, features and

product; notify the carrier immediately of any damage, which you believe occurred during

shipment or delivery. Inspect the contents of this package for any signs of damage and

Examine the shipping container for obvious damage prior to installing this

1 External Power Supply, (for -Hd, -Hi, -Pd and -Pi models only)

1 Magnum CSG14 Series Converter Switch unit,

2.1 Inspecting the Package and the Product

ensure that the items listed below are included.

2.0 INTRODUCTION

This package should contain:

typical applications.

Page 23 of the GarrettCom CSG14 user manual — 2.2 Product Description
Page 23 · click to enlarge
Page 23

container. Be sure to keep the shipping container should you need to ship the unit at a later

date. In the event there are items missing or damaged contact your supplier. If you need to

return the unit, use the original shipping container. Refer to Section 5 Troubleshooting, for

network Ethernet product. Add in fiber port choices for all multi-mode and single-mode

10/100/1000 copper Switch, and you have the Converter Switch, a flexible edge-of-the-

Remove the Magnum CSG14 Series Converter Switch from the shipping

Combine a 10, 100 or 1000Mb Fiber Media Converter and a two-port

1 set Metal panel mounting clips and screws (2 each)

1 User Guide (this manual)

specific return procedures.

2.2 Product Description

Page 24 of the GarrettCom CSG14 user manual — 2.2 Product Description
Page 24 · click to enlarge
Page 24

10Mb Fiber port built in covers the full range of application environments, with Hardened

offers the best price-to-value ratio for each user and installation. Where a Media Converter

The Magnum CSG14 family of Converter Switches with a 1000Mb, 100Mb or

(factory floor), and Premium-rated (outdoor) versions. Extra features for heavy-duty and

extended temperature operation ranges are included selectively in the Hardened factory-

floor and Premium-rated outdoor models. This selection of models and fiber port types

might have been used, a Converter Switch offers a better value. The compact package is

ideal for network edge installations, and is able to be conveniently mounted to suit any

fiber connector types plus AC or DC input power selection and multiple application

environments, and you have the Magnum CSG14 Converter Switch family.

application.

Page 25 of the GarrettCom CSG14 user manual — 2.2 Product Description
Page 25 · click to enlarge
Page 25

jobs. In addition to a Hardened AC power option and jack, terminals for internal DC power

choices at 8 to15V, 24V or -48V DC are included. The ambient temperature rating of –25

dirt, moisture, smoke and insects. Mounting options include stand-alone panel mounting,

applications (-40 to 75C), typically located outdoors. The CSG14P models are built with

premium-grade extended temperature components, and use similar thermal techniques as

constructed using special thermal techniques and a metal case for heavy-duty industrial

to 60C is for industrial use. No internal airflow is required for cooling, so it resists dust,

The Magnum CSG14P Premium-rated units are for temperature un-controlled

The Magnum CSG14H Hardened units are for the office and factory floor

applications. The CSG14H models are built with high-grade components and are

DIN-Rail, or rack-mount tray.

Page 26 of the GarrettCom CSG14 user manual — 2.2 Product Description
Page 26 · click to enlarge
Page 26

used outdoors, the CSG14P should be protected from falling rain. Mounting options include

plug-and-play, energy-efficient, and flavor rich fiber features make this sleek multi-purpose

ports and one 1000Mb fiber port which may be SC or LC multi-mode or single-mode. The

the CSG14H Hardened units. In addition to a Premium-rated AC power option and jack,

terminals for internal DC power choices at 8 to15V, 24V or -48V DC are included. When

The CSG14 series provides switching between two 10/100/1000 auto-negotiating copper

ranges enable easy deployment in various environments and qualify the Converter Switch

as a flexible option, which provides multiple solutions using very small space. Providing

the combination of Media Converter with Switch, the CSG14 Series is an ideal choice for

Switch convenient and cost-effective for the user. The selection of various temperature

stand-alone panel mounting, DIN-rail, or rack-mount tray.

edge-of–the-network applications.

Page 27 of the GarrettCom CSG14 user manual — CSG14H with 1000Mb SC connector
Page 27 · click to enlarge
Page 27

designed for office and wiring closet environments and factory floor/Industrial applications.

Using special thermal techniques and a sealed rugged metal case for heavy-duty industrial

applications no air inflow is required for cooling, so the CSG14H resist dust, dirt, moisture,

smoke and insects. Choices of models for external AC or internal DC power are available.

Ambient operating temperature is –25°C to + 60°C depending on the power source used.

The ORANGE labeled Magnum CSG14H hardened units (as shown in Fig 2.2a) are

GarrettCom CSG14 — CSG14H with 1000Mb SC connector diagram (page 27)
Fig. 6 · CSG14H with 1000Mb SC connector

Storage temperature rating is –40°C to + 100°C

CSG14H with 1000Mb SC connector

Fig 2.2a

Page 28 of the GarrettCom CSG14 user manual — CSG14H with 1000Mb SC connector
Page 28 · click to enlarge
Page 28

The RED labeled Magnum CSG14P Series (as shown in Fig. 2.2b) are premium rated units

mounting, DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC

power are available. Ambient operating temperature is between –40°C to +75°C depending

premium-grade extended temperature components, the CSG14P units use similar thermal

techniques to the CSG14H hardened units for cooling. Mounting options include panel

suitable for temperature un-controlled outdoor applications. Specially designed with

on the power source used. Storage temperature rating is between –40°C to +100°C.

GarrettCom CSG14 — CSG14H with 1000Mb SC connector diagram (page 28)
Fig. 7 · CSG14H with 1000Mb SC connector

CSG14P with 1000Mb LC connector

Fig 2.2.b

Page 29 of the GarrettCom CSG14 user manual — CSG14H with 1000Mb SC connector
Page 29 · click to enlarge
Page 29

Two sets of LEDs indicating the operating status of ports are mounted on the top

and front (for extra viewing advantage while rack-mounted). For each port, there are Link

The front side of the unit has two twisted-pair 10/100/1000Mb switch ports and

and Activity (LK/ACT) LED’s on the top indicating that the media cables are connected

one 10, 100 or 1000Mb fiber port. Both the RJ-45 ports of the CSG14 Series Converter

switches support auto cross (MDIX) operation performing the autocross function under

auto-negotiation mode only. The CSG14 models are factory configured at Full Duplex.

repeated on the front as LA1 (port 1), LA2 (port 2), and LA3 (port 3). There is a power

correctly and showing, by blinking, when there is traffic. The LK/ACT LED’s are

(PWR) indicator on the front of the unit to validate that the unit is turned ON.

Page 30 of the GarrettCom CSG14 user manual — 2.3 Frame Buffering and Latency
Page 30 · click to enlarge
Page 30

Each frame (or packet) is loaded into the Switch’s memory and inspected before forwarding

The single fiber port on the CSG14 is multi-mode with an SC connector or small

The Magnum CSG14 Series Converter Switches are store-and-forward switches.

can occur. This technique ensures that all forwarded frames are of a valid length and have

The external DC power plug connector and/or “jack” and the internal DC input

the correct CRC, i.e. they are good packets. This eliminates propagation of bad packets,

While other switching technologies such as "cut-through" or "express" impose

enabling all of the available bandwidth to be used for valid information.

terminal is provided on the rear of the unit.

form-factor connector (LC single-mode).

2.3 Frame Buffering and Latency

Page 31 of the GarrettCom CSG14 user manual — 2.3 Frame Buffering and Latency
Page 31 · click to enlarge
Page 31

storage. (Many other switches have their packet buffer storage space divided evenly across

minimal frame latency, they will also permit bad frames to propagate out to the Ethernet

there is no way to filter frames with a bad CRC (the entire frame must be present in order

traffic congestion, especially at peak activity. Since collisions and bad packets are more

Magnum CSG14 Series Converter Switch dynamically allocates buffer space from 64Kb

memory pool, ensuring that heavily used ports receive very large buffer space for packet

which are a result of late collisions, to be forwarded to add to the network traffic. Since

for CRC to be calculated), the result of indiscriminate cut-through forwarding is greater

segments connected. The "cut-through" technique permits collision fragment frames,

likely when traffic is heavy, the result of store-and-forward operation is that more

To minimize the possibility of dropping frames on congested ports, each

bandwidth is available for good packets when the traffic load is greatest.

Page 32 of the GarrettCom CSG14 user manual — 2.3 Frame Buffering and Latency
Page 32 · click to enlarge
Page 32

all ports, resulting in a small, fixed number of packets to be stored per port. When the port

aggregate density, the Magnum CSG14 Series Converter Switches are constantly adapting

When the Switch detects that its free buffer queue space is low, the Switch sends

buffering and processing resumes. This flow-control sequence occurs in a small fraction of

capability for the maximum resources of the Magnum CSG14 Series unit to be applied to

industry standard (full-duplex only) PAUSE packets out to the devices sending packets to

which allows a traffic catch-up to occur without dropping packets. Then, normal packet

all traffic loads, even when the traffic activity is unbalanced across the ports. Since the

cause “flow control”. This tells the sending devices to temporarily stop sending traffic,

traffic on an operating network is constantly varying in packet density per port and in

buffer fills up, dropped packets result.) This dynamic buffer allocation provides the

internally to provide maximum network performance with the least dropped packets.

Page 33 of the GarrettCom CSG14 user manual — 2.3 Frame Buffering and Latency
Page 33 · click to enlarge
Page 33

from entering by forcing a collision signal on all receiving half-duplex ports in order to stop

Another feature implemented in Magnum CSG14 Series Converter Switches is a

collision-based flow-control mechanism (when operating at half-duplex only). When the

forwarded to its destination) of the CSG14 Series Converter Switches varies with the port-

switches. For 10 Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the

Switch detects that its free buffer queue space is low, the Switch prevents more frames

The latency (the time the frame spends in the Switch before it is sent along or

speed types. The length of the frame is a variable as it is with all store-and-forward

a second and is transparent to an observer. See Section 4.6 for additional details.

latency is 15 microseconds plus the packet time at 10 Mb. For 100Mb-to-100Mb

forwarding, the latency is 5 microseconds plus the packet time at 100Mb.

incoming traffic.

Page 34 of the GarrettCom CSG14 user manual — Ethernet LANs
Page 34 · click to enlarge
Page 34

2.4 Features and Benefits „ Full 1000Mb, 100Mb or 10 Mb switching services for high performance

giving each port’s segment a full 1000Mb, 100Mb or 10 Mb of bandwidth.

inexpensively connect a Twisted Pair and fiber network with 10Mb, 100Mb

1000Mb fiber port allows the user to convert the media from copper to fiber

Magnum CSG14 Series Switches offer the ideal solution to efficiently and

or 1000Mb and help to expand the Ethernet network in a very convenient

Magnum CSG14 Series Switches provide Fast Ethernet switching on all

„ Choice of 10, 100 or 1000Mb Fiber option, more efficient than media

Designed as a multi-purpose media converter and Switch, the 10, 100 or

ports. They perform high-speed filter/forward operations on the traffic,

„ Reduces Network Costs and provide economical solution

and economical way.

Ethernet LANs

converter

Page 35 of the GarrettCom CSG14 user manual — Ethernet LANs
Page 35 · click to enlarge
Page 35

top) of LEDs to provide status information when viewed at almost any angle

CSG14 Series have a robust design and are packaged in a rugged sheet metal

domains. Internal address tables are self-learning, enabling users to change

The Magnum CSG14 Series Switches operate as hardware switches, only

Each CSG14 Series Converter Switch is equipped with two sets (front and

„ Installation is “Plug and Play”, operation is transparent to software

forwarding those packets from each domain that are needed on the other

port connections or 10/100/1000 domains without affecting operations.

or mounting arrangement whether rack (MC14- Tray) or wall-mounted.

enclosure to ensure high reliability and durability even when placed in

and the other RJ-45 port can be used as diagnostic port or for more

„ Two sets of LEDs for viewing status from any angle.

„ Rugged metal case, Industrial grade

industrial or outdoor applications.

connectivity.

Page 36 of the GarrettCom CSG14 user manual — Ethernet LANs
Page 36 · click to enlarge
Page 36

The Magnum CSG14P Premium rated versions of Converter Switches

spaces in cabinets, on table tops, in racks, wall or DIN rail mounted and in trays

„ Qualified to use for temperature un-controlled “outdoor” application

have an ambient temperature rating between –40C to +75C for DC models and

supply, Magnum CSG14 Series of Converter Switches can be installed in small

All the Magnum CSG14 Series Switches are featured with MDIX (auto-cross),

Featuring a compact steel case with an external AC and internal DC power

which easily allow cascading with other Switch Hubs or media converters,

„ Efficient Compact design, for all purpose convenient mounting

„ MDIX ports to eliminate cross-over cable while cascading

qualify for temperature un-controlled “outdoor” application.

such as the Magnum MC14-TRAY.

without using the cross-over cable.

Page 37 of the GarrettCom CSG14 user manual — 2.5 Applications for CSG14 Series Converter Switches
Page 37 · click to enlarge
Page 37

fast expanding network requirements. The Triple-Speed and Dual-media functions support

providing easier, more economical and ultra-reliable industrial application products. The

compactly designed Magnum CSG14 Series act as very useful tools in the modern life of

media. The up-link choice of 10, 100 or 1000Mb fiber on Port# 1 enables easy expansion

“Premium rated (outdoor)”), the multifunctional, multi-media and multi-environmental,

network connectivity solutions offered by Magnum Converter Switches are focused on

a mixed environment of 10 Mbps, 100Mbps and 1000Mbps users with copper and fiber

for the on-going demand of Ethernet networks. The 10/100/1000Mbps auto-negotiating

Enriched with the two tier “O-R” hardness rating flavors (Orange –“Hardened”, Red-

Magnum CSG14 Series Converter Switches fit very well in almost any environment

enabling users to scale their networks quickly and cost effectively. The edge-of-the-

2.5 Applications for CSG14 Series Converter Switches

Page 38 of the GarrettCom CSG14 user manual — 2.5 Applications for CSG14 Series Converter Switches
Page 38 · click to enlarge
Page 38

equipment. The Magnum CSG14Ps fit very well in high temperature locations experiencing

copper ports together with the 10, 100 or 1000Mbps fiber port choices and the availability

the industry standard fiber connectors, enable easy interfacing with existing cable plant and

easily solve long distance requirements. The ruggedness of the CSG14P’s steel case and

economical high bandwidth solution at each cable user access point of copper, and also

the high reliability of the design compliment the temperature-controlled packaging to

a need to scale the LAN quickly and cost effectively. The CSG14Ps provide a very

provide an exceptional Ethernet product.

Page 39 of the GarrettCom CSG14 user manual — LK/ACT
Page 39 · click to enlarge
Page 39
GarrettCom CSG14 — LA3 LA2 LA1 diagram (page 39)
Fig. 8

CS14P Convenient Switches provided a secure dependable,

reliable solution for un-controlled temp. environment

M a g n u m m P 6 2 G arrettC om

W W W .G a r r e t t C o m .C o m

Example 1Indoor Office CSG14

W W W . G a r re t tC om . C om

M a g n u m m P 6 2

LA3 LA2 LA1

PWR F/H

2 3 A FF

Port 3 Port 2 Port 1 10Mb/s

M a gn u m C SN 1 4

FH1

and Workstations 100Mb Servers 100

and Workstations 100Mb Servers 100

F/H

LK/ACT

POWER

Port 1 Port 2 Port 3

LK/ACT

LK/ACT

Co nv ert er Sw itch

W W W .G a r r e ttC om .C om

12 Vdc 0.5 Amp

Show 5 more labels / short text on this page
Test computer · 10/100 · 10/100 · GarrettCom · IBM Compatible
Page 40 of the GarrettCom CSG14 user manual — LA3 LA2 LA1
Page 40 · click to enlarge
Page 40

across large distances with multi- or single–mode fiber while securing the LAN from EMI

demand to grow the network. This need can be easily met using the economical Magnum

CSG14 Converter Switch. Additional functionality includes the ability to transfer data

In this example, the indoor office location is a Data Mining function with an ongoing

and wire-tapping.

Page 41 of the GarrettCom CSG14 user manual — LK/ACT
Page 41 · click to enlarge
Page 41
GarrettCom CSG14 — Example 2: CSG14H diagram (page 41)
Fig. 9 · Example 2: CSG14H

W W W . G a r r e ttC o m .C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

W W W .G a rr e ttC o m . C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

W W W . G a r r e ttC o m .C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

Example 2: CSG14H

and Workstations 100Mb Servers 100

GARRETT

GARRETT

LA3 LA2 LA1

2 3 A FF

PWR F/H

Port 3 Port 2 Port 1 10Mb/s

Magnum C SN 14

FH1

POWER

Port 1 Port 2 Port 3

LK/ACT

LK/ACT

Converter S w itch

W W W .G a r r e ttC o m .C o m

LK/ACT

F/H

12 Vdc 0.5 Amp

Show 10 more labels / short text on this page
100Mb Servers 100 · Power · Power · Error · Error · Tx Rx UPLINK · Tx Rx UPLINK · 10/100 · 10/100 · GarrettCom
Page 42 of the GarrettCom CSG14 user manual — Example 2: CSG14H
Page 42 · click to enlarge
Page 42

having no openings for dirt to enter, the CSG14 Series Converter Switches provide the very

Ethernet ports to carry status and control data to the control center the hardened version of

Magnum CSG14H is typically used. . The Fiber port on the converter switches is ideal for

In this application, where in expanding an industrial network environment, the new PLC

secure data communications over long distances that may be encountered in this edge of

network application. Built with high-grade components, efficient cooling techniques and

units are deployed on an existing network and each needs one (or two for redundancy)

effective solution for this need.

Page 43 of the GarrettCom CSG14 user manual — F H = X
Page 43 · click to enlarge
Page 43
GarrettCom CSG14 — UPLINK 3 4 5 6 7 8 1SW diagram (page 43)
Fig. 10

W W W .G a r r e ttC om .C om

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

Tx Rx UPLINK Tx Rx UPLINK and Workstations 100Mb Servers 100

W W W .G a rr e ttC o m .C om

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

W W W .G a rr e tt C o m .C o m

W W W .G a r r e t t C o m .C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

Example 3CSG14P

LA3 LA2 LA1

2 3 A FF

12V, 1.5Amps Magnum DS80C Dual Speed

12V, 1.5Amps Magnum DS80C Dual Speed

12V, 1.5Amps Magnum DS80C Dual Speed

PWR F/H

Port 3 Port 2 Port 1 10Mb/s

FH1

UPLINK 3 4 5 6 7 8 1SW

UPLINK 3 4 5 6 7 8 1SW

UPLINK 3 4 5 6 7 8 1SW

Port 1 Port 2 Port 3

LK/ACT

M a g nu m CS N 1 4

C onverter Sw itch

W W W .G a r r e t tC o m .C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

POWER

LK/ACT

2SW

2SW

2SW

and Workstations 100Mb Servers 100

and Workstations 100Mb Servers 100

and Workstations 100Mb Servers 100

and Workstations 100Mb Servers 100

and Workstations 100Mb Servers 100

and Workstations 100Mb Servers 100

LK/ACT

F/H

12 Vdc0.5 Amp

F/H

GARRETT

F/H

GARRETT

F/H

GARRETT

Tx Rx UPLINK Tx Rx UPLINK

F H = X

F H = X

F H = X

Show 20 more labels / short text on this page
CCTV Camera · 10/100 · GarrettCom · Personal Hub · Personal Hub · Personal Hub · 10/100 · Link/Act Speed · Link/Act Speed · Link/Act Speed · Power · Error · Power · Error · Power · Error · Tx Rx UPLINK · Tx Rx UPLINK · Tx Rx UPLINK · Tx Rx UPLINK
Page 44 of the GarrettCom CSG14 user manual — UPLINK 3 4 5 6 7 8 1SW
Page 44 · click to enlarge
Page 44

In this example, the Magnum CSG14P Premium Converter Switches are deployed to serve

as a secure corporate or transportation surveillance system. CCTV cameras may be spread

allowing a full range of AC and DC power options. The second copper port at the remote

location provides access for other Ethernet equipment such as motion detectors or will act

out over many miles in temperature un-controlled locations and with pan, tilt and zoom

(PTZ) controlled through an Ethernet copper port .The premium Converter Switches are

ideally suited to providing copper to fiber media conversion for secure long distance (2-

70km) communication while being installed in temperature un-controlled cabinets and

as a test port for maintenance personnel with up-link for access to a central LAN and

central file servers.

Page 45 of the GarrettCom CSG14 user manual — 3.0 INSTALLATION
Page 45 · click to enlarge
Page 45

This section describes the installation of the Magnum CSG14 Series Converter

Switches, including location; mountings and power supply options and media connection.

Secure attachment of

clips for panel -

economical tool to expand an existing network.

store and forward switch easily takes care of

3.1 Locating the Converter Switch Unit

All the CSG14 Series Switches operate in

transparent half-and full-duplex mode. The

network traffic and can be used as a useful,

3.0 INSTALLATION

Page 46 of the GarrettCom CSG14 user manual — Secure attachment of
Page 46 · click to enlarge
Page 46

shelf. Alternatively, metal mounting clips and screws are included for a rugged and secure

Installation of the Magnum CSG14 Series Converter Switches is a simple procedure.

The installation location is dependent upon the physical layout of the Ethernet network and

easily installed in almost any location. A Velcro strip may be used for mounting the unit

associated cabling. Make sure the unit is installed in a location that is easily accessible to

an AC power outlet or the appropriate DC source and where cooling is not inhibited. The

The compact and lightweight design of the Magnum CSG14 Series allows it to be

on a vertical surface such as a wall or cabinet, or for securing the unit on a table-top or

green Power (PWR) LED must turn ON when power is applied.

mounting in any orientation.

Page 47 of the GarrettCom CSG14 user manual — Secure attachment of
Page 47 · click to enlarge
Page 47
GarrettCom CSG14 — Secure attachment of diagram (page 47)
Fig. 11 · Secure attachment of

spaces of the MC14-TRAY are specific to the Magnum products and will not permit other

Media Converters may be placed on a tray, up to a maximum of 16 units. (The mounting

3.2 MC14-TRAY for Rack Mounting of CSG14 Series Switches For 19” rack-mounting

DC power jack in the back, with

connectors in the front. Any mix

of the Converter Switches and/or

models to be properly mounted).

Switches are mounted with the

MC14-TRAY. The Converter

Converter Switches, a rack-

mount tray is available, the

of Magnum CSG14 Series

the fiber and the RJ-45

Page 48 of the GarrettCom CSG14 user manual — 3.3 MC14-TR+PS9 and MC14-TR+PS9X2 for Rack Mounting Media Converters
Page 48 · click to enlarge
Page 48

strips (not included) in the rear area of the tray. Metal mounting screws in the bottom-front

The MC14-TR+ PS9 and MC14-TR+PS9X2 are other options for rack mounting the mix of

hold the Converter Switches firmly in place. The beveled-top edge of the units permits the

together in a 19” rack-mount tray. These models come with built-in common universal AC

In a typical installation, the MC14-TRAY, 19” rack-mount tray will hold a few (three to

LEDs of each unit to be viewed for operational status, even when the units are very close

power supply rated at 55 watts at 50°C ambient, 9 VDC regulated output, and supporting

up to 10 Switches for MC14-TR+PS9 and 16 units CSG14 Series for MC14-TR+PS9X2.

eight) CSG14 Series Converter Switches, with their power supplies plugged into power

3.3 MC14-TR+PS9 and MC14-TR+PS9X2 for Rack Mounting Media Converters

Magnum 10Mbps, 100Mbps and 1000Mbps Converter Switches and Media Converters

together.

Page 49 of the GarrettCom CSG14 user manual — 3.3 MC14-TR+PS9 and MC14-TR+PS9X2 for Rack Mounting Media Converters
Page 49 · click to enlarge
Page 49

tray. (PS units that come with the MC’s

The MC14-TR+PS9X2 Model has two groups of eight units per power supply. The power

TR+PS9, 19” rack-mount tray, holding

Converters, each with their power input

The side-view below is an example of

plugged into the built-in common AC

a few CSG14, FT14 and 14E Media

power supply in the rear area of the

an installation of the model MC14-

are not used).

supplies have auto-ranging AC input for use worldwide.

GarrettCom CSG14 — 3.3 MC14-TR+PS9 and MC14-TR+PS9X2 for Rack Mounting Media Converters diagram (page 49)
Fig. 12 · 3.3 MC14-TR+PS9 and MC14-TR+PS9X2 for Rack Mounting…
Page 50 of the GarrettCom CSG14 user manual — A Magnum CSG14H is shown
Page 50 · click to enlarge
Page 50

securing them in the tray and enabling separate removal for service. The dual LEDs permit

The metal DIN-Rail mounting hardware is optional and needs to be ordered as a

GarrettCom CSG14 — A Magnum CSG14H is shown diagram (page 50)
Fig. 13 · A Magnum CSG14H is shown

It comes with four screws to attach the bracket to the MC unit. The rail clip is

spring-loaded with a pull-up latch at the top for easy “snap-on” attachment and removal.

Metal mounting screws in the bottom-front hold each of the media converters

CSG14PR Converter Switches, designed for use

environments, are also available for DIN-Rail

separate item, e.g. Model #DIN-RAIL-MC2.

mounting in an enclosure having DIN Rails.

A Magnum CSG14H is shown

viewing of Switch status from any angle.

3.4 DIN-Rail mounting option The Magnum CSG14HR and

alongside the DIN-Rail-MC2 bracket

in “Factory Floor” Industrial Ethernet

Page 51 of the GarrettCom CSG14 user manual — 3.5 Power Requirements, Power Supply Types for CSG14 Series Switches
Page 51 · click to enlarge
Page 51

The Magnum CSG14 models with “HR” have 24VDC power, and have the DIN-

version. The extended temperature (H and P) versions are used for heavy-duty industrial

The 12V DC power input has a plug of 2.5mm, center +ve , with 6 ft. cord. All the AC

Magnum CSG14 Series Switches are power-efficient and can work with an

external AC power supply. Magnum CSG14 Series require a nominal 12VDC input

The CSG14 Series are designed to be used with UL listed Class II power

supplies. The CSG14H and CSG14P converter switches provide reliable operation,

3.5 Power Requirements, Power Supply Types for CSG14 Series Switches

Rail-MC2 bracket included and assembled with the MC unit at the factory.

power supply info detail is provided in Technical Specifications Section 1.1.

applications.

Page 52 of the GarrettCom CSG14 user manual — 12VDC 24VDC -48VDC
Page 52 · click to enlarge
Page 52

withstand higher temperature environments, and provide the DC power choices to the user

ground. The 9V DC jack is also present. Detail information about the 12 VDC, the 24V DC

only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like).

and the –48V DC is provided in the Technical Specifications Section 1.1.

The various models of DC power type and extended ambient temperature power supplies

The Direct DC (Internal) 12V DC (8 – 15V DC) has a built-in terminal block for +, -,

12VDC 24VDC -48VDC

are numerous and your choice needs to be called out on your order.

to deploy in uncontrolled temperature environments.

Page 53 of the GarrettCom CSG14 user manual — 12VDC 24VDC -48VDC
Page 53 · click to enlarge
Page 53

temperature uncontrolled environments, rated at –40`C to +75`C. If indoors, the DC jack is

GarrettCom CSG14 — 12VDC 24VDC -48VDC diagram (page 53)
Fig. 14
GarrettCom CSG14 — 12VDC 24VDC -48VDC diagram (page 53)
Fig. 15

3.6 Powering the CSG14H and CSG14P (DC internal) with 12V, 24V or –48VDC power input

The extended temperature capability of the DC-powered CSG14P’s can go

12VDC, 24VDC or -48VDC power. DC power

Series is reliably equipped with an internal DC

for secure attachment of the power leads. Three

power supply, and has built-in screw terminals

models support a range of power input types.

input may be chosen for high-availability.

The three model choices are for use with

Each Magnum CSG14H/CSG14P-

Page 54 of the GarrettCom CSG14 user manual — 18 – 36V DC (24V DC)
Page 54 · click to enlarge
Page 54
GNDTerminal for “earth” or ground wire connection to the CSG14H chassis

also present and optionally can be used with an external AC power supply.

Power Consumption: 4 watts typical, 5 watts max.

36 – 60V DC (-48V DC)

0.4 amp max.(24V DC)

0.2 amp max.(-48V DC)

Input Voltage8 - 15V DC (12V DC)

18 – 36V DC (24V DC)

Input current0.8 amp.(12V DC)
DC Power Terminals“+”, “-”, gnd
Page 55 of the GarrettCom CSG14 user manual — 3.7 CSG14H and P Series, DC-powered, -48VDC, 24VDC and 12VDC Installation
Page 55 · click to enlarge
Page 55
GarrettCom CSG14 — 3.7 CSG14H and P Series, DC-powered, -48VDC, 24VDC and 12VDC Installation diagram (page 55)
Fig. 16 · 3.7 CSG14H and P Series, DC-powered, -48VDC, 24VDC a…
GarrettCom CSG14 — 3.7 CSG14H and P Series, DC-powered, -48VDC, 24VDC and 12VDC Installation diagram (page 55)
Fig. 17 · 3.7 CSG14H and P Series, DC-powered, -48VDC, 24VDC a…

3.7 CSG14H and P Series, DC-powered, -48VDC, 24VDC and 12VDC Installation

This section describes the proper connection of the -48VDC leads (or 24VDC,

ground either of the terminals. The chassis is “earth” or ground (GND).

the Magnum CSG14H is located on the left side of

the unit and is equipped with three (3) screw-down

12VDC leads) to the DC power terminal block on

the Magnum CSG14H hardened media converter

lead posts. The power terminals are identified as

positive (+) and negative (-), and they are floating

(as shown in Figure). The DC terminal block on

inside the unit so that the user if desired may

Page 56 of the GarrettCom CSG14 user manual — 3.7 CSG14H and P Series, DC-powered, -48VDC, 24VDC and 12VDC Installation
Page 56 · click to enlarge
Page 56

The connection procedure is straightforward. Simply insert the DC leads to the

and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead

types i.e. fiber and copper (RJ-45) types, run at 1000BASE-T, 100BASE-TX, 10BASE-T

3.8 Connecting Ethernet Media The Magnum CSG14 Series Converter Switch can be connected to two media

and 1000BASE-SX/LX/ZX, 100BASE-FX, or 10BASE-FL. CAT 5E cables should be

(GND) optional; it connects to the CSG14H chassis. Ensure that each lead is securely

CSG14H’s power terminals, positive (+) and negative (-) screws. The use of Ground

will connect to the post-labeled “+ve” and the rest to the “-ve”.

When power is applied, the green PWR LED will illuminate.

tightened from the top, as shown here.

The GND can be hooked up at the last.

Page 57 of the GarrettCom CSG14 user manual — 3.7 CSG14H and P Series, DC-powered, -48VDC, 24VDC and 12VDC Installation
Page 57 · click to enlarge
Page 57

used when making 1000BASE-T connections. When the ports are used as 10BASE-T ports,

cabling is 100 meters (328 ft). For fiber port 10BASE-FL, 100BASE-FX or 1000BASE-SX

9/125 microns cabling should be used. Fiber cabling supports much longer cable distance and higher bandwidths as compared to copper wiring.

multi-mode, 50/125 or 62.5/125 microns cabling can be used, whereas for single-mode,

CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair

Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45

Twisted Pair (CAT 5) 100BASE-TX RJ-45

Media IEEE Standard Connector

Fiber (Single-mode) 100BASE-FX SC, LC

Fiber (Multi-mode, Single-mode) 1000BASE-SX SC, LC

Twisted pair (CAT5E or Higher) 1000BASE-T RJ-45

Fiber (Multi-mode) 10BASE-FL SC

Fiber (Multi-mode) 100BASE-FX SC

Fiber (Single-mode) 1000BASE-LX/ZX LC

Page 58 of the GarrettCom CSG14 user manual — Shielded)
Page 58 · click to enlarge
Page 58

or 1000BASE-T twisted pair segment to the RJ-45 port. The procedure is the same for both

sensing for either 10,100 or 1000Mbps. Note that the auto-cross function does

The following procedure describes how to connect a 10BASE-T, 100BASE-TX

1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded,

3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or

2. Connect the other end of the cable to the corresponding device. 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be

100Mbps and 1000Mbps) be used whenever possible in order to provide flexibility in a mixed-speed network, since P80-series switch ports are auto-

not operate, if the port is fixed or not supporting auto-negotiation.

either unshielded or shielded cables and wiring may be used.

unshielded and shielded twisted pair cables.

Shielded)

Page 59 of the GarrettCom CSG14 user manual — 3.8.3 Connecting Fiber Optic SC-type, "Snap-In"
Page 59 · click to enlarge
Page 59

does not help, ensure that the cable is connected properly and that the device on the

3.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)”

The following procedure applies to installations using LC-type fiber connectors,

The following procedure applies to installations using SC-type fiber connectors,

illuminated when the unit is powered and proper connection is established. If this

4. For Port # 1 or 1SW, if the LINK LED is not illuminated, move the switch which has a cross-over or up-link for linking to another hub or Switch.

simply snap on the two square male connectors into the LC female jacks of the

simply snap on the two square male connectors into the SC female jacks of the

i.e., using LC single-mode. While connecting fiber media to LC connectors,

i.e., using multi-mode SC. While connecting fiber media to SC connectors,

3.8.3 Connecting Fiber Optic SC-type, "Snap-In"

Fiber connector until it clicks and secures.

Fiber connector until it clicks and secures.

other end is powered and is not defective.

Page 60 of the GarrettCom CSG14 user manual — 3.8.4 Connecting Single-Mode Fiber Optic
Page 60 · click to enlarge
Page 60

connectors. Single-mode fiber cable has a smaller diameter than multi-mode

fiber cable (9/125 microns for single-mode, 50/125 or 62.5/125 microns for

multi-mode where xx/xx are the diameters of the core and the core plus the

Receiver Sensitivity and Transmitter Power are the parameters necessary to

When using single-mode fiber cable, be sure to use single-mode fiber port

cladding respectively). Single-mode fiber allows full bandwidth at longer

The same procedures as for single-mode fiber apply to multi-mode fiber

compute the power budget. To calculate the power budget of different fiber media

3.8.5 Power Budget Calculations for CSG14 Series, Fiber Media

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

installations using Magnum products, the following equations should be used:

connectors. Follow the steps listed in Section 3.8.3 above.

distances, about 70km with the single-mode LC.

3.8.4 Connecting Single-Mode Fiber Optic

OPB (Optical Power Budget) = PT(min) - PR(min)

Page 61 of the GarrettCom CSG14 user manual — 3.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)”
Page 61 · click to enlarge
Page 61

Siemens’) web sites and catalogs to provide guidance to network designers and installers

The following data has been collected from component manufacturer’s (HP’s, and

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

where the “Cable Loss” for 62.5/125 and 50/125μm (m.m.) is 2.8 dB/km,

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

Page 62 of the GarrettCom CSG14 user manual — CSG14-
Page 62 · click to enlarge
Page 62
GarrettCom CSG14 — 3.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)” diagram (page 62)
Fig. 18 · 3.8.2 Connecting Fiber Optic LC-type, “Small Form fa…

mode 0.55 850 62.5/125 50/125 -9.5 -17 5.5 2 12.5 4

-mode 10 1310 9/125 -9.5 -20 8.5 17 10.5 21

-mode 25 1310 9/125 -4.0 -21 15 37.5 17.5 43

-mode 40 1550 9/125 -4.0 -21 15 60 17.5 70

-mode 70 1550 9/125 -3.0 -23 18 90 20.5 102

SX 1000Mb SX Multi-

Std.

CSG14-

CSG14-

CSG14-

CSG14-

ZX40

CSG14-

ZX70

Show 8 more labels / short text on this page
1000Mb LX Single · 1000Mb LX Single · 1000Mb ZX Single · Speed, · 1000Mb ZX · Fiber · Port · Module
Page 63 of the GarrettCom CSG14 user manual — 3.8.6 Connections to NICs which support Auto-Negotiation, RJ-45 ports
Page 63 · click to enlarge
Page 63

NIC to the CSG14 Series, it may be necessary to reload the NIC drivers on the user device

100BASE-TX). When 1000Mb operation is agreed and in use, the Gb LED is illuminated

* Note: The use of either multi-mode or single-mode fiber to operate at 1000Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following

3.8.6 Connections to NICs which support Auto-Negotiation, RJ-45 ports

Fast Link Pulse (FLP) coding for the 1000BASE-T signaling system. When connecting a

  • The worst-case OPB of the fiber link must be greater than the fiber cable’s

The copper ports of Magnum CSG14 Series Converter Switches will function

properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the

  • The 1000Mb fiber segment must operate in full-duplex (FDX) mode, and

if the NIC has been communicating with a protocol other than 1000BASE-T (such as

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

passive Attenuation.

factors are both applied:

Page 64 of the GarrettCom CSG14 user manual — 4.0 OPERATION
Page 64 · click to enlarge
Page 64

speed, and auto cross for plug polarity. (See Section 2.2). When the connected device is 10

users can “communicate” with 100Mbps users as well as other 10 Mbps users through the

The Magnum CSG14 Series Converter Switches provide three switched ports.

Mbps, the CSG14s obey all the rules of 10 Mbps Ethernet configurations. The 10 Mbps

Magnum CSG14 Series units are plug-and-play devices. There is no software

The switched RJ-45 ports are full- or half-duplex auto-sensing for mode and

switch. Similarly, the 100Mbps traffic obeys the rules of 100Mbps Ethernet, and can

The architecture supports a triple speed-switching environment, with standard auto-

4.1 Triple-Speed Functionality, and Switching

steady ON and is OFF, for 10 or 100Mbps traffic.

communicate with 10 Mb and 100Mb users.

4.0 OPERATION

negotiation capability.

Page 65 of the GarrettCom CSG14 user manual — Switching, Filtering and Forwarding
Page 65 · click to enlarge
Page 65

configuring to be done at installation or for maintenance. The only hardware configuration

the same port segment will be filtered, constraining them to one port and relieving the rest

settings are user options for port #2, to configure it FF/AN. The internal functions of both

Each time a packet arrives on one of the switched ports, the decision is taken to

either filter or to forward the packet. Packets whose source and destination addresses on

ports where it is not needed. Packets needed for maintaining the operation of the network

of the network from processing them. A packet whose destination address is on another

port segment will be forwarded to the appropriate port, and will not be sent to the other

(such as occasional multi-cast packets) are forwarded to all ports. The Magnum CSG14

Series Converter Switches operate in the store-and-forward switching mode, which

Switching, Filtering and Forwarding

are described below.

Page 66 of the GarrettCom CSG14 user manual — Switching, Address Learning
Page 66 · click to enlarge
Page 66

An address-aging algorithm causes least-used addresses to fall out in favor of new

eliminates bad packets and enables peak performance to be achieved when there is heavy

nodes are added or removed or moved from one segment to another, the CSG14 Series

addresses, and are suitable for use in large networks. They are self-learning, so that as

The RJ-45 ports support auto cross (MDI or MDIX) in the auto-negotiation

The Magnum CSG14 Series units have address table capacity of 1K node

mode according to the IEEE 802.3z standard. No crossover cables are needed when

frequently used addresses. To reset the address buffer, cycle power down-and-up.

4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing

switch automatically keeps up with node locations.

Switching, Address Learning

traffic on the network.

Page 67 of the GarrettCom CSG14 user manual — 3.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)”
Page 67 · click to enlarge
Page 67

connecting the CSG14’s to other unmanaged switches, legacy hubs, managed switches,

where the switch manager fixes the port settings via software, and the result of the auto-

negotiation is changed in the managed switch by the manager commands. In such cases,

device at the other end of the cable should similarly advertise / respond. Both sides will

agree to the speed and mode to be used per the IEEE 802.3z standard. Depending upon

media-converters etc. Please note that there can be conditions with managed switches

the 10/100/1000 speed or the F/H mode may be affected, but auto-cross in the CSG14

advertises its capability for 10, 100 or 1000Mbps speed and F/H duplex mode, and the

When an RJ-45 cable connection is made, and each time LINK is enabled,

auto-negotiation takes place (except for legacy products, which do not have auto-

negotiation and which go to the default state accordingly). The Magnum Switch

Switches will still work. The auto cross function cannot be disabled.

Page 68 of the GarrettCom CSG14 user manual — 4.3 Dual LEDs, Front-panel and side-panel LED Description
Page 68 · click to enlarge
Page 68

segment or a loss of power occurs in the unit or remote device. The Link ports are

LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK

will turn off in the event connectivity is lost between the ends of the twisted pair

also represented by LA1, LA2, and LA3. (Steady On or steady Off indicates no

the devices connected, this will result in agreement to operate at 10Mbps, 100Mbps or

Gb Steady ON for 1000Mb speed, OFF for 100Mb or 10Mb speed per port

PWR Illuminates GREEN to indicate power applied.

1000Mbps speed, and full- or half-duplex mode.

4.3 Dual LEDs, Front-panel and side-panel LED Description

Receive Activity).

Page 69 of the GarrettCom CSG14 user manual — 5.0 TROUBLESHOOTING
Page 69 · click to enlarge
Page 69

Switch is not performing as expected, do not attempt to repair the unit; instead contact your

Should problems develop during installation or operation, this section is intended

to help locate, identify and correct these types of problems. Please follow the suggestions

consistently high performance in all network environments. The installation of Magnum

INSTALLATION, Section 3.0); the operation is also straightforward and is discussed in

procedures described in this section or if the Magnum CSG14 Series 10/100/1000 Mb/s

listed below prior to contacting your supplier. However, if you are unsure of the

All Magnum Ethernet products are designed to provide reliability and

CSG14 Series 10/100/1000 Mb/s Switches is a straightforward procedure (see

5.0 TROUBLESHOOTING

Section 4.

Page 70 of the GarrettCom CSG14 user manual — 3.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)”
Page 70 · click to enlarge
Page 70

into a functioning electrical outlet. Use the PWR LEDs to verify each unit is

5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back

to the Installation Section of the applicable chapter of this manual. Also

2. Check the cables and connectors to ensure that they have been properly

impaired during installation. (About 90% of network downtime can be

3. Make sure that an AC power cord is properly attached to each Magnum

connected and the cables/wires have not been crimped or in some way

check to make sure that the various components of the network are

CSG14 Series unit. Be certain that the AC power cord is plugged

supplier for assistance or contact GarrettCom Customer Support.

attributed to wiring and connector problems.)

receiving power.

interoperable.

Page 71 of the GarrettCom CSG14 user manual — 3.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)”
Page 71 · click to enlarge
Page 71

the problem device is replaced with a known good device. Verify whether or

5. If the problem continues after completing Step 4 above, contact your supplier

not the problem is corrected. If not, go to Step 5 below. If the problem is

CSG14 Series 10/100/1000 Mb/s switch product, it is recommended that

4. If the problem is isolated to a network device other than the Magnum

of the Magnum CSG14 Series 10/100/1000 Mb/s Switch unit or if

corrected, the Magnum CSG14 Series Switch and its associated

unknown, contact GarrettCom, Inc by fax, phone or email

(support@garrettcom.com) for assistance.

cables are functioning properly.

Page 72 of the GarrettCom CSG14 user manual — 5.2 When Calling for Assistance
Page 72 · click to enlarge
Page 72
2. An accurate list of GarrettCom product model(s)involved, with serial number(s).

including convenient computers, workstations, terminals and printers; plus, the

d. Any particular application that, when used, appears to create the problem;

3. It is useful to include other network equipment models and related hardware,
1. A complete description of the problem, including the following points:

Include the date(s) that you purchased the products from your supplier.

Please be prepared to provide the following information.

c. The components involved in the problem;

a. The nature and duration of the problem;

various network media types being used.

b. Situations when the problem occurs;

5.2 When Calling for Assistance

Page 73 of the GarrettCom CSG14 user manual — 5.3 Return Material Authorization (RMA) Procedure
Page 73 · click to enlarge
Page 73

All returns for repair must be accompanied by a Return Material Authorization

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the

4. A record of changes that have been made to your network configuration prior

to the occurrence of the problem. Any changes to system administration

(RMA) number. To obtain an RMA number, please use this URL -

form. Please have the following information readily available:

5.3 Return Material Authorization (RMA) Procedure

Name and phone number of your contact person.

procedures should all be noted in this record.

Name of your company / institution

Serial Number (or Invoice Number)

Your shipping address · Product name

Page 74 of the GarrettCom CSG14 user manual — repaired units to the sender with shipping charges prepaid (see Warranty
Page 74 · click to enlarge
Page 74

duplicate the problem or condition causing the return, the unit will be returned as:

Information, Appendix A, for complete details). However, if GarrettCom cannot

GarrettCom will carefully test and evaluate all returned products, will repair

products that are under warranty at no charge, and will return the warranty-

repaired units to the sender with shipping charges prepaid (see Warranty

Failure symptoms, including a full description of the problem.

Packing List Number (or Sales Order Number)

Date of installation

Page 75 of the GarrettCom CSG14 user manual — 5.4 Shipping and Packaging Information
Page 75 · click to enlarge
Page 75
1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet

GarrettCom reserves the right to charge for the testing of non-defective units

under warranty. Testing and repair of product that is not under warranty will result in a

Should you need to ship the unit back to GarrettCom, please follow these instructions:

or bag for shipping protection. (You may retain all connectors and this

No Problem Found.

5.4 Shipping and Packaging Information

Installation Guide.)

customer (user) charge.

Page 76 of the GarrettCom CSG14 user manual — 47823 Westinghouse Drive Fremont, CA 94539
Page 76 · click to enlarge
Page 76
2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.
3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to: GarrettCom, Inc.

This material may cause electro-static shock damage to the unit.

47823 Westinghouse Drive Fremont, CA 94539

Attn.: Customer Service

Page 77 of the GarrettCom CSG14 user manual — APPENDIX A: WARRANTY INFORMATION
Page 77 · click to enlarge
Page 77

During this warranty period, GarrettCom will repair or, at its option, replace components in

This warranty will not be effective if, in the opinion of GarrettCom, GarrettCom

has damaged by misuse, misapplication, or as a result of service or modification other than

Please complete the warranty card as this acts as a product registration, and mail

GarrettCom, Inc. warrants its products to be free from defects in materials and

the product. GarrettCom reserves the right to make a charge for handling and inspecting

workmanship for a period of three (3) years from the date of shipment by GarrettCom.

the products that prove to be defective at no charge other than shipping and handling,

any product returned for warranty repair which turns out not to be faulty.

provided that the product is returned pre-paid to GarrettCom.

APPENDIX A: WARRANTY INFORMATION

it to GarrettCom within two weeks of your purchase.

Ask about the GarrettCom CSG14

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom CSG14

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom CSG14 manual PDF

77 pages·573 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…