Magnum CSG14 Gigabit Converter Switches






GarrettCom is a registered trademark and Magnum, Dymec, DynaStar, Personal
Switch, Link-Loss-Learn, S-Ring, Convenient Switch and Converter Switch
UL is a registered trademark of Underwriters Laboratories
NEBS is a trademark of Telcordia Technologies
Ethernet is a trademark of Xerox Corporation
are trademarks of GarrettCom, Inc.
Trademarks

Switches contain no user serviceable parts. Attempted service by unauthorized
Copyright © 2008 GarrettCom, Inc. All rights reserved. No part of this publication may
GarrettCom, Inc. reserves the right to change specifications, performance characteristics
experienced with Magnum CSG14 10/100/1000 Mb/s Converter Switch
be reproduced without prior written permission from GarrettCom, Inc.
personnel shall render all warranties null and void. If problems are
products, consult Section 5, Troubleshooting, of this User Guide.
Printed in the United States of America
and/or model offerings without notice.

This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user, at his/her own expense, will be required to take
Radio Frequency Interference Statement
whatever measures may be required to correct the interference.
Federal Communications Commission

which has suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable
power unit, marked Class 2, or listed ITE Power Supply, marked LPS,
ONLY be replaced by GarrettCom personnel through the RMA process.
(Dedicated Equipment Rooms, Electrical Closets, or the like).
circuit breaker in the supply circuit when connected to a 48V
Electrical Safety requirements:
rated output current.
centralized source.

Please use the mailing address, phone and fax numbers and email address listed below:
47823 Westinghouse Drive Fremont, CA 94539
GarrettCom, Inc.
Fax (510) 438-9072 · Contacting GarrettCom, Inc



3.4 DIN-Rail mounting option 49
3.5 Power Requirements for CSG14 Series Switches 50
3.6 Powering the CSG14 with 12V, 24V or –48VDC power input 51
3.7 CSG14 Series, DC-powered, -48, 24 and 12VDC Installation 53
3.8 Connecting Ethernet Media 55
3.8.1 Connecting Twisted Pair (RJ-45, CAT 3, CAT 5 or CAT 6,
Unshielded or Shielded) 56
3.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)” ... 57
3.8.3 Connecting Fiber Optic SC-type, "Snap-In" 58
3.8.4 Installing LC-type SFP module,“Small Form Pluggable (SFP)” 58
3.8.5 Connecting Single-Mode Fiber Optic 58
3.8.6 Power Budget Calculations for CSG14 Series, Fiber Media 59
3.8.7 Connections to NICs which support Auto-Negotiation 61
4.1 Triple-Speed Functionality, and Switching 62
4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing 64
4.3 Dual LEDs, Top-front and in End with ports 65

5.1 Before Calling for Assistance 67
5.2 When Calling for Assistance 68
5.3 Return Material Authorization (RMA) Procedure 70
5.4 Shipping and Packaging Information 72
added mounting hole location drawing (page 43)
“LX25” on pages 12 and 13

Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.
Filter and Forward Rate from 1000Mbps ports: 1,488,000 pps max.
Filter and Forward Rate from 100Mbps ports: 148,800 pps max.
1000Mb: Ethernet IEEE 802.3ab and 802.3z 1000Base-T, -SX, -LX and -ZX 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3z
Address buffer age-out time: 300 sec.
1.1 Technical Specifications Ports Performance
Network Standards

10BASE-T (Unshielded twisted pair) 100 m (328 ft) 10BASE-FL, Fiber optic 2 km (6,562 ft) 10BASE-FL, Single-mode Fiber optic 10 km (32,810ft)
100BASE-TX (CAT 5 UTP) 100 m (328 ft) 100BASE-FX, half-duplex: (multi-mode) 412 m (1350 ft) 100BASE-FX, full duplex: (multi-mode) 2 km (6,562 ft) 100BASE-FX, half-duplex: (single-mode) 412 m (1350 ft) 100BASE-FX, full duplex: (single-mode) 20 km (65,620 ft) 100BASE-FX, full duplex: (single-mode, long reach) 40 km (131,240 ft) 1000BASE-T (CAT5E OR CAT6 recommended) 100 m (328 ft) 1000BASE-SX, full duplex, multi-mode (62.5um) 220 m (722 ft) 1000BASE-SX, full duplex, multi-mode (50um) 550 m (1804 ft)
Maximum Ethernet Segment (or Domain) Lengths

1000BASE-LX, full duplex, single-mode (9um) 5 km (16404 ft) 1000BASE-ZX, full duplex, single-mode (9um) >70 km (229,659 ft)
CSG14H / CSG14UH: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL)
CSG14P / CSG14UP: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL)
-40ºF to 185ºF (-40ºC to 85ºC) Short term per IEC Type tests
-40ºF to 185ºF (-40ºC to 85ºC) Short term per IEC Type tests
Conformal Coating (optional) for humidity protection
Cold Start:
CSG14H / CSG14UH to -20ºC
CSG14P / CSG14UP to -40ºC
Operating Environment · Storage Temperature,

Convection on the CSG14 Series models. The hardened (H) factory floor and premium (P)
temperature un-controlled location models have closed cases to withstand dirt and use
special thermal techniques to transfer heat to the outside of the case for cooling.
3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x 2.5 cm)
Dimensions of the Switch unit:
and altitude.
Cooling Method:

All models have a (8-15) VDC output with 6ft long cord and a 2.5mm center +ve jack. The
International (-Hi) models. Factory floor temperature rated. Input: IEC 320 connector on
North America (-Hd) models. Hardened, factory floor temperature rated. Input: 6ft AC
power cord to IEC 320 connector on the 100-240vac 47-63Hz external power adapter.
the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord
power supplies are temperature rated to match the Converter Switch ratings.
Factory Floor (H) Ratings (-25 to 60°C)
Output: 12vdc, 1.25Amps.




Temperature un-controlled Premium (P) Ratings (-40 to 75°C)
external power adapter. Requires a user supplied power cord.
12V DC internal (range of 8.0 to 15V DC) 24V DC internal (range of 18 to 36V DC). -48V DC internal (range of 36 to 60V DC), -, ground
North America (-Pd) models. Outdoor temperature rated.
International (-Pi) models. Outdoor temperature rated.
240vac 47-63Hz external power adapters. Output: 12vdc, 2Amps.
+, -, ground along with 12VDC jack
Output: 12vdc, 2Amps.

It is shielded 8-pin female connector for shielded (STP) and unshielded (UTP)
/ -ZX with a “fiber flavor” choice of multimode or singlemode SFP connectors.
They are shielded 8-pin female connectors for shielded (STP) and unshielded
“fiber flavor” choice of multimode or singlemode SC, SLC, SFP connectors.
the DC terminal block. Power supply protection is provided by internal diodes.
Two RJ-45 Ports: supports 10/100/1000Mbps with auto cross (MDIX).
One RJ-45 Port: supports 10/100/1000Mbps with auto cross (MDIX).
Port Connectors (CSG14UH / CSG14UP:
Port Connectors (CSG14H / CSG14P:
Power Consumption: See Section 3.6.
(UTP) Cat 3, 4, 5 cables.
Cat 3, 4, 5 cables.

User may select 100Mb speed via DIP switch on the back of the unit
Each SFP port is individually speed-selectable
Fiber port default is FDX (Full-Duplex)
RJ45’s are triple-speed auto-negotiating
Each SFP port is factory set to Gb speed
Switches (CSG14UH / CSG14UP)
Switches (CSG14H / CSG14P)
setting to take effect.

POWER
LK/ACT
LK/ACT
PORT 3
PORT 1 PORT 2 PORT 3
traffic, BLINKING for Activity
LED Indicators (Two sets) top-front and end with ports
100Mbps or 10Mb speed LK/ACT per port: Steady ON for LINK (LK) with no
traffic, BLINKING for Activity
End with Ports:

Mean Time Between Failure (MTBF) – over15 years, Telcordia (Bellcore) Method
UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A.
IEC61850 EMC and Operating Conditions Class C Power Substations
Metal mounting clips for panel mounting: included
Agency Approvals and Standards Compliance:
NEBS L3 and ETSI compliant.
Mounting options

factory floor (-25 to 60C) using a direct DC ( 8-15VDC) and/or external
CSG14H-ff-Hd, Hi = Hardened (H), two 10/100/1000Mb RJ-45+ one 1000Mb Fiber port for
except AC hardened power supply is not included
but includes DIN-RAIL-MC2 mounting option.
except 24VDC power input replaces 12VDC.
except -48VDC power input replaces 24VDC
AC hardened power supply (included).
CSG14H-ff-24VDC = Same as CSG14H-12VDC model,
CSG14HR-ff-24VDC = Same as CSG14H-24VDC model,
CSG14H-ff-48VDC = Same as CSG14H-24VDC model,
CSG14H-ff-12VDC = Same as CSG14H model,
1.2 Summary of models and descriptions:
CSG14H (Hardened Model) for 1000Mb fiber

CSG14P-ff-48VDC = Same as CSG14P-24VDC model, except -48VDC input replaces 24VDC.
CSG14P-ff-Pd, Pi = Premium (P), two 10/100/1000Mb RJ-45+ one 1000Mb Fiber port for un-
controlled(outdoor) (-40 to 75C) using direct DC (8-15VDC) and/or
CSG14P-ff-12VDC = Same as CSG14P-Pd, Pi, except AC Premium Power Supply is not
“SX” = 1000Base-SX-SC: 850nm multi-mode fiber optic with SC type connector, 550 m.
external AC premium power supply (included).
but includes DIN-RAIL-MC2 mounting option.
except 24VDC power input replaces 12VDC.
The “ff” field is for selection of the desired “fiber flavor” as listed below.
CSG14P-ff-24VDC = Same as CSG14P-12VDC model,
CSG14PR-ff-24VDC = Same as CSG14P-24VDC model,
CSG14P (Premium Model) for 1000Mb fiber
Fiber Port Connectors (CSG14H / CSG14P):
included.

CSG14UH-ff-Hd, Hi = Hardened (H), one 10/100/1000Mb RJ-45+ two 1000Mb Fiber ports for
factory floor (-25 to 60C) using a direct DC ( 8-15VDC) and/or external
“SFP” = open SFP transceiver slot in the fiber position. (order SFP as a separate item)
except AC hardened power supply is not included
AC hardened power supply (included).
CSG14UH-ff-24VDC = Same as CSG14UH-12VDC model,
CSG14UH-ff-12VDC = Same as CSG14UH model,
CSG14UH (Hardened Model) for 1000Mb fiber

CSG14UP-ff-Pd, Pi = Premium (P), one 10/100/1000Mb RJ-45+ two 1000Mb Fiber ports for un-
CSG14UP-ff-48VDC = Same as CSG14UP-24VDC model, except -48VDC input replaces 24VDC
controlled(outdoor) (-40 to 75C) using direct DC (8-15VDC) and/or
CSG14UP-ff-12VDC = Same as CSG14UP-Pd, Pi, except AC Premium Power Supply is not
but includes DIN-RAIL-MC2 mounting option.
external AC premium power supply (included).
but includes DIN-RAIL-MC2 mounting option.
except 24VDC power input replaces 12VDC.
except -48VDC power input replaces 24VDC
except 24VDC power input replaces 12VDC.
CSG14UHR-ff-24VDC = Same as CSG14UH-24VDC model,
CSG14UH-ff-48VDC = Same as CSG14UH-24VDC model,
CSG14UP-ff-24VDC = Same as CSG14UP-12VDC model,
CSG14UPR-ff-24VDC = Same as CSG14UP-24VDC model,
CSG14UP (Premium Model) for 1000Mb fiber
included.

Other Tray configurations with power supplies and power cabling included - See Section 3.3
“SFP” = open SFP transceiver slot in the fiber position. (order SFP as a separate item)
DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one CSG14 Series Switch,
MC14-TRAY = 19” Rack-mount tray for 14-series Switch models, up to 16 units
Conformal Coating (for high humidity and “tropical” applications) - request quote.
The “ff” field is for selection of the desired “fiber flavor” as listed below.
“SFP100P-FXSM15”= 100Base-FX, single-mode SFP, 15Km
“SFP100P-FXSM40”= 100Base-FX, single-mode SFP, 40Km
“SFP100P-FXMM2”= 100Base-FX, multi-mode SFP, 2Km
Fiber Port Connectors (CSG14UH / CSG14UP):
See Section 3.4
Accessories

This section describes CSG14 Series models, including appearance, features and
product; notify the carrier immediately of any damage, which you believe occurred during
shipment or delivery. Inspect the contents of this package for any signs of damage and
Examine the shipping container for obvious damage prior to installing this
1 External Power Supply, (for -Hd, -Hi, -Pd and -Pi models only)
1 set Metal panel mounting clips and screws (2 each)
1 User Guide (this manual)
1 Magnum CSG14 Series Converter Switch unit,
2.1 Inspecting the Package and the Product
ensure that the items listed below are included.
This package should contain:
typical applications.

container. Be sure to keep the shipping container should you need to ship the unit at a later
date. In the event there are items missing or damaged contact your supplier. If you need to
return the unit, use the original shipping container. Refer to Section 5 Troubleshooting, for
10Mb Fiber port built in covers the full range of application environments, with Hardened
10/100/1000 copper Switch, and you have the Converter Switch, a flexible edge-of-the- network Ethernet product. Add in fiber port choices for all multi-mode and single-mode
The Magnum CSG14 family of Converter Switches with a 1000Mb, 100Mb or
fiber connector types plus AC or DC input power selection and multiple application
Remove the Magnum CSG14 Series Converter Switch from the shipping
Combine a 10, 100 or 1000Mb Fiber Media Converter and a two-port
environments, and you have the Magnum CSG14 Converter Switch family.
2.2.1 CSG14H / CSG14P Product Description
specific return procedures.
2.2 Product Description

offers the best price-to-value ratio for each user and installation. Where a Media Converter
jobs. In addition to a Hardened AC power option and jack, terminals for internal DC power
(factory floor), and Premium-rated (outdoor) versions. Extra features for heavy-duty and
choices at 8 to15V, 24V or -48V DC are included. The ambient temperature rating of –25
dirt, moisture, smoke and insects. Mounting options include stand-alone panel mounting,
extended temperature operation ranges are included selectively in the Hardened factory-
floor and Premium-rated outdoor models. This selection of models and fiber port types
might have been used, a Converter Switch offers a better value. The compact package is
ideal for network edge installations, and is able to be conveniently mounted to suit any
constructed using special thermal techniques and a metal case for heavy-duty industrial
to 60C is for industrial use. No internal airflow is required for cooling, so it resists dust,
The Magnum CSG14H Hardened units are for the office and factory floor
applications. The CSG14H models are built with high-grade components and are
DIN-Rail, or rack-mount tray.
application.

used outdoors, the CSG14P should be protected from falling rain. Mounting options include
The CSG14 series provides switching between two 10/100/1000 auto-negotiating
single-mode. The plug-and-play, energy-efficient, and flavor rich fiber features make this
various temperature ranges enables deployment in various industrial environments. And, it
applications (-40 to 75C), typically located outdoors. The CSG14P models are built with
premium-grade extended temperature components, and use similar thermal techniques as
the CSG14H Hardened units. In addition to a Premium-rated AC power option and jack,
terminals for internal DC power choices at 8 to15V, 24V or -48V DC are included. When
The Magnum CSG14P Premium-rated units are for temperature un-controlled
sleek multi-purpose Switch convenient and cost-effective for the user. The selection of
uses very little space. Providing the combination of Media Converter with Switch, the
copper ports and one 1000Mb fiber port which may be SC, LC or SFP multi-mode or
CSG14 Series is an ideal choice for edge-of–the-network applications.
stand-alone panel mounting, DIN-rail, or rack-mount tray.

cooling, so the CSG14H resist dust, dirt, moisture, smoke and insects. Choices of models
25°C to + 60°C depending on the power source used. Storage temperature rating is –40°C to + 100°C

for external AC or internal DC power are available. Ambient operating temperature is –
Fig 2.2.1a
CSG14H with 1000Mb SC connector
heavy-duty industrial applications no air inflow is required for
The ORANGE labeled Magnum CSG14H hardened units (as
shown in Fig 2.2.1a) are designed for office and wiring closet
environments and factory floor/Industrial applications. Using
special thermal techniques and a sealed rugged metal case for

DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC power are

available. Ambient operating temperature is between –40°C to +75°C depending on the
power source used. Storage temperature rating is between –40°C to +100°C.
Fig 2.2.1b
CSG14P with 1000Mb LC connector
premium-grade extended temperature components, the CSG14P
units use similar thermal techniques to the CSG14H hardened
The RED labeled Magnum CSG14P Series (as shown in Fig.
units for cooling. Mounting options include panel mounting,
2.2.1b) are premium rated units suitable for temperature un- controlled outdoor applications. Specially designed with

Two sets of LEDs indicating the operating status of ports are mounted on the top
and front (for extra viewing advantage while rack-mounted). For each port, there are Link
The single fiber port on the CSG14 is multi-mode with an SC connector or small
The front side of the unit has two twisted-pair 10/100/1000Mb switch ports and
and Activity (LK/ACT) LED’s on the top indicating that the media cables are connected
The external DC power plug connector and/or “jack” and the internal DC input
one 10, 100 or 1000Mb fiber port. Both the RJ-45 ports of the CSG14 Series Converter
switches support auto cross (MDIX) operation performing the autocross function under
auto-negotiation mode only. The CSG14 models are factory configured at Full Duplex.
repeated on the front as LA1 (port 1), LA2 (port 2), and LA3 (port 3). There is a power
correctly and showing, by blinking, when there is traffic. The LK/ACT LED’s are
(PWR) indicator on the front of the unit to validate that the unit is turned ON.
terminal is provided on the rear of the unit.
form-factor connector (LC single-mode).

be plugged in. It can also handle any 100Mb fiber media type and distance in the same way,
media attachment, there is a 10/100/1000 auto-negotiating RJ-45 port. Where Gb Ethernet
fiber media distance with a selection of Gb SFP fiber transceivers, up to two of which can
100Mb Fiber ports available to cover the full range of application environments, with Hardened (factory floor), and Premium-rated (outdoor) versions. Extra features for heavy-
duty and extended temperature operation ranges are included selectively in the Hardened
factory-floor and Premium-rated outdoor models. This selection of models and fiber port
Converter Switch. It can handle any Gb fiber type – multi-mode and single-mode – and
with a selection of 100Mb SFP fiber transceivers that similarly plug in. And, for copper
The latest technology of SFP fiber transceivers has been integrated into the
types offers the best price-to-value ratio for each user and installation. Where a Media
Magnum Gb Converter Switch package to produce the Magnum CSG14U Universal
The Magnum CSG14U family of Converter Switches have two 1000Mb or
2.2.2 CSG14UH / CSG14UP Product Description
is in use, the CSG14U converts all media combinations.

jobs. In addition to a Hardened AC power option and jack, terminals for internal DC power
applications (-40 to 75C), typically located outdoors. The CSG14UP models are built with
the CSG14UH Hardened units. In addition to a Premium-rated AC power option and jack,
package is ideal for network edge installations, and is able to be conveniently mounted to
choices at 8 to15V, 24V or -48V DC are included. The ambient temperature rating of –25
dirt, moisture, smoke and insects. Mounting options include stand-alone panel mounting,
The Magnum CSG14UP Premium-rated units are for temperature un-controlled
premium-grade extended temperature components, and use similar thermal techniques as
Converter might have been used, a Converter Switch offers a better value. The compact
constructed using special thermal techniques and a metal case for heavy-duty industrial
to 60C is for industrial use. No internal airflow is required for cooling, so it resists dust,
The Magnum CSG14UH Hardened units are for the office and factory floor
applications. The CSG14UH models are built with high-grade components and are
DIN-Rail, or rack-mount tray.
suit any application.

single-mode. The plug-and-play, energy-efficient, and flavor rich fiber features make this
various temperature ranges enables deployment in various industrial environments. And, it
terminals for internal DC power choices at 8 to15V, 24V or -48V DC are included. When
negotiating copper port and two 100 or 1000Mb fiber ports which are SFP multi-mode or
sleek multi-purpose Switch convenient and cost-effective for the user. The selection of
uses very little space. Providing the combination of Media Converter with Switch, the
used outdoors, the CSG14UP should be protected from falling rain. Mounting options
The CSG14U series provides switching between one 10/100/1000 auto-
CSG14U Series is an ideal choice for edge-of–the-network applications.
include stand-alone panel mounting, DIN-rail, or rack-mount tray.


insects. Choices of models for external AC or internal DC power are available. Ambient
operating temperature is –25°C to + 60°C depending on the power source used. Storage
Fig 2.2.2a
CSG14UH with two SFP slots
cooling, so the CSG14UH resist dust, dirt, moisture, smoke and
The ORANGE labeled Magnum CSG14UH hardened units (as
heavy-duty industrial applications no air inflow is required for
shown in Fig 2.2.2a) are designed for office and wiring closet
environments and factory floor/Industrial applications. Using
special thermal techniques and a sealed rugged metal case for
temperature rating is –40°C to + 100°C

Ambient operating temperature is between –40°C to +75°C depending on the power source

rack-mount tray. Choices of models for external AC or internal DC power are available.
Fig 2.2.2b
CSG14UP with two SFP slots
2.2.2b) are premium rated units suitable for temperature un- controlled outdoor applications. Specially designed with premium-
grade extended temperature components, the CSG14UP units use
cooling. Mounting options include panel mounting, DIN-rail, or
used. Storage temperature rating is between –40°C to +100°C.
The RED labeled Magnum CSG14UP Series (as shown in Fig.
similar thermal techniques to the CSG14UH hardened units for

two 100 or 1000Mb fiber ports. The RJ-45 port of the CSG14U Series Converter switches
Two sets of LEDs indicating the operating status of ports are mounted on the top
and front (for extra viewing advantage while rack-mounted). For each port, there are Link
The two fiber ports on the CSG14U are multi-mode or single-mode with a small
The external DC power plug connector and/or “jack” and the internal DC input terminal is
The front side of the unit has one twisted-pair 10/100/1000Mb switch port and
and Activity (LK/ACT) LED’s on the top indicating that the media cables are connected
repeated on the front as LA1 (port 1), LA2 (port 2), and LA3 (port 3). There is a power
negotiation mode only. The CSG14U models are factory configured at Full Duplex.
correctly and showing, by blinking, when there is traffic. The LK/ACT LED’s are
support auto cross (MDIX) operation performing the autocross function under auto-
(PWR) indicator on the front of the unit to validate that the unit is turned ON.
form-factor connector (LC multi-mode or LC single-mode).
provided on the rear of the unit.

Each frame (or packet) is loaded into the Switch’s memory and inspected before forwarding
2.3 Frame Buffering and Latency The Magnum CSG14 Series Converter Switches are store-and-forward switches.
can occur. This technique ensures that all forwarded frames are of a valid length and have
the correct CRC, i.e. they are good packets. This eliminates propagation of bad packets,
While other switching technologies such as "cut-through" or "express" impose
minimal frame latency, they will also permit bad frames to propagate out to the Ethernet
there is no way to filter frames with a bad CRC (the entire frame must be present in order
traffic congestion, especially at peak activity. Since collisions and bad packets are more
which are a result of late collisions, to be forwarded to add to the network traffic. Since
for CRC to be calculated), the result of indiscriminate cut-through forwarding is greater
segments connected. The "cut-through" technique permits collision fragment frames,
likely when traffic is heavy, the result of store-and-forward operation is that more
To minimize the possibility of dropping frames on congested ports, each
enabling all of the available bandwidth to be used for valid information.
bandwidth is available for good packets when the traffic load is greatest.

storage. (Many other switches have their packet buffer storage space divided evenly across
all ports, resulting in a small, fixed number of packets to be stored per port. When the port
aggregate density, the Magnum CSG14 Series Converter Switches are constantly adapting
When the Switch detects that its free buffer queue space is low, the Switch sends
buffering and processing resumes. This flow-control sequence occurs in a small fraction of
Magnum CSG14 Series Converter Switch dynamically allocates buffer space from 64Kb
memory pool, ensuring that heavily used ports receive very large buffer space for packet
capability for the maximum resources of the Magnum CSG14 Series unit to be applied to
industry standard (full-duplex only) PAUSE packets out to the devices sending packets to
which allows a traffic catch-up to occur without dropping packets. Then, normal packet
all traffic loads, even when the traffic activity is unbalanced across the ports. Since the
cause “flow control”. This tells the sending devices to temporarily stop sending traffic,
traffic on an operating network is constantly varying in packet density per port and in
buffer fills up, dropped packets result.) This dynamic buffer allocation provides the
internally to provide maximum network performance with the least dropped packets.
a second and is transparent to an observer. See Section 4.6 for additional details.

from entering by forcing a collision signal on all receiving half-duplex ports in order to stop
Another feature implemented in Magnum CSG14 Series Converter Switches is a
collision-based flow-control mechanism (when operating at half-duplex only). When the
forwarded to its destination) of the CSG14 Series Converter Switches varies with the port-
switches. For 10 Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the
Switch detects that its free buffer queue space is low, the Switch prevents more frames
The latency (the time the frame spends in the Switch before it is sent along or
speed types. The length of the frame is a variable as it is with all store-and-forward
latency is 15 microseconds plus the packet time at 10 Mb. For 100Mb-to-100Mb
forwarding, the latency is 5 microseconds plus the packet time at 100Mb.
incoming traffic.

2.4 Features and Benefits Full 1000Mb, 100Mb or 10 Mb switching services for high performance
giving each port’s segment a full 1000Mb, 100Mb or 10 Mb of bandwidth.
inexpensively connect a Twisted Pair and fiber network with 10Mb, 100Mb
1000Mb fiber port allows the user to convert the media from copper to fiber
Magnum CSG14 Series Switches offer the ideal solution to efficiently and
or 1000Mb and help to expand the Ethernet network in a very convenient
Magnum CSG14 Series Switches provide Fast Ethernet switching on all
Choice of 10, 100 or 1000Mb Fiber option, more efficient than media
Designed as a multi-purpose media converter and Switch, the 10, 100 or
ports. They perform high-speed filter/forward operations on the traffic,
Reduces Network Costs and provide economical solution
and economical way.
Ethernet LANs · converter

top) of LEDs to provide status information when viewed at almost any angle
CSG14 Series have a robust design and are packaged in a rugged sheet metal
domains. Internal address tables are self-learning, enabling users to change
The Magnum CSG14 Series Switches operate as hardware switches, only
Each CSG14 Series Converter Switch is equipped with two sets (front and
Installation is “Plug and Play”, operation is transparent to software
forwarding those packets from each domain that are needed on the other
port connections or 10/100/1000 domains without affecting operations.
or mounting arrangement whether rack (MC14- Tray) or wall-mounted.
enclosure to ensure high reliability and durability even when placed in
and the other RJ-45 port can be used as diagnostic port or for more
Two sets of LEDs for viewing status from any angle.
Rugged metal case, Industrial grade
industrial or outdoor applications.
connectivity.

The Magnum CSG14P Premium rated versions of Converter Switches have
installed in small spaces in cabinets, on table tops, in racks, wall or DIN rail
Qualified to use for temperature un-controlled “outdoor” application
an ambient temperature rating between –40C to +75C for DC models and
Featuring a compact aluminum case with an external AC and internal DC
All the Magnum CSG14 Series Switches are featured with MDIX (auto-
cross), which easily allow cascading with other Switch Hubs or media
power supply, Magnum CSG14 Series of Converter Switches can be
Efficient Compact design, for all purpose convenient mounting
qualify for temperature un-controlled “outdoor” application.
MDIX ports to eliminate cross-over cable while cascading
mounted and in trays such as the Magnum MC14-TRAY.
converters, without using the cross-over cable.

Enriched with the two tier “O-R” hardness rating flavors (Orange –“Hardened”,
of-the-network connectivity solutions offered by Magnum Converter Switches are focused
The compactly designed Magnum CSG14 Series act as very useful tools in the modern life
support a mixed environment of 10 Mbps, 100Mbps and 1000Mbps users with copper and
negotiating copper ports together with the 10, 100 or 1000Mbps fiber port choices and the
locations experiencing a need to scale the LAN quickly and cost effectively. The CSG14Ps
environment enabling users to scale their networks quickly and cost effectively. The edge-
environmental, Magnum CSG14 Series Converter Switches fit very well in almost any
on providing easier, more economical and ultra-reliable industrial application products.
availability the industry standard fiber connectors, enable easy interfacing with existing
of fast expanding network requirements. The Triple-Speed and Dual-media functions
expansion for the on-going demand of Ethernet networks. The 10/100/1000Mbps auto-
fiber media. The up-link choice of 10, 100 or 1000Mb fiber on Port# 1 enables easy
cable plant and equipment. The Magnum CSG14Ps fit very well in high temperature
Red- “Premium rated (outdoor)”), the multifunctional, multi-media and multi-

copper, and also easily solve long distance requirements. The ruggedness of the CSG14P’s
aluminum case and the high reliability of the design compliment the temperature-controlled
provide a very economical high bandwidth solution at each cable user access point of
packaging to provide an exceptional Ethernet product.



Magnum CSG14 Converter Switch. Additional functionality includes the ability to transfer
ongoing demand to grow the network. This need can be easily met using the economical
data across large distances with multi- or single–mode fiber while securing the LAN from
EMI and wire-tapping.



hardened version of Magnum CSG14H is typically used. . The Fiber port on the converter
efficient cooling techniques and having no openings for dirt to enter, the CSG14 Series
encountered in this edge of network application. Built with high-grade components,
new PLC units are deployed on an existing network and each needs one (or two for
redundancy) Ethernet ports to carry status and control data to the control center the
switches is ideal for secure data communications over long distances that may be
Converter Switches provide the very effective solution for this need.



motion detectors or will act as a test port for maintenance personnel with up-link for access
cameras may be spread out over many miles in temperature un-controlled locations and
with pan, tilt and zoom (PTZ) controlled through an Ethernet copper port .The premium
Converter Switches are ideally suited to providing copper to fiber media conversion for
controlled cabinets and allowing a full range of AC and DC power options. The second
copper port at the remote location provides access for other Ethernet equipment such as
secure long distance (2-70km) communication while being installed in temperature un-
deployed to serve as a secure corporate or transportation surveillance system. CCTV
to a central LAN and central file servers.


easily extended or expanded as conditions
capability that enables connecting many
disparate devices in a fiber-media string,
and devices needing network attachment
covering even very long distances (for
backbone LAN with a “Drop & Add”
example, a pipeline). Such designs are
In this example, Magnum CSG14U
Converter Switches form a gigabit
change over time.
capability


This section describes the installation of the Magnum CSG14 Series Converter
options and media connection.
care of network traffic and can
mountings and power supply
3.1 Locating the Converter Switch Unit
economical tool to expand an
duplex mode. The store and
forward switch easily takes
Series Switches operate in
be used as a useful,
existing network.
Switches, including location; · All the CSG14 · transparent half-and full-

The compact and lightweight design of the Magnum CSG14 Series allows it to be
shelf. Alternatively, metal mounting clips and screws are included for a rugged and secure
procedure. The installation location is dependent upon the physical layout of the Ethernet
easily installed in almost any location. A Velcro strip may be used for mounting the unit
network and associated cabling. Make sure the unit is installed in a location that is easily
on a vertical surface such as a wall or cabinet, or for securing the unit on a table-top or
accessible to an AC power outlet or the appropriate DC source and where cooling is not
Installation of the Magnum CSG14 Series Converter Switches is a simple
inhibited. The green Power (PWR) LED must turn ON when power is applied.
mounting in any orientation.


mount tray is available, the MC14-TRAY. The Converter Switches are mounted with the
DC power jack in the back, with the fiber and the RJ-45 connectors in the front. Any mix
3.2 MC14-TRAY for Rack Mounting of CSG14 Series Switches For 19” rack-mounting of Magnum CSG14 Series Converter Switches, a rack-
of the Converter Switches and/or Media Converters may be placed on a tray, up to a
mounting spaces of the MC14-
Magnum products and will not
19” rack-mount tray will hold a few (three to eight) CSG14
maximum of 16 units. (The
TRAY are specific to the
permit other models to be
properly mounted).
installation, the MC14-TRAY, · Series Converter Switches, · In a typical


with their power supplies plugged into power strips (not included) in the rear area of the
tray. Metal mounting screws in the bottom-front hold the Converter Switches firmly in
place. The beveled-top edge of the units permits the LEDs of each unit to be viewed for
operational status, even when the units are very close together.
The MC14-TR+ PS9 and
MC14-TR+PS9X2 are other options
1000Mbps Converter Switches and Media Converters together in a 19”
universal AC power supply rated at
3.3 MC14-TR+PS9 and MC14- TR+PS9X2 for Rack Mounting
55 watts at 50°C ambient, 9 VDC
Magnum 10Mbps, 100Mbps and
rack-mount tray. These models
for rack mounting the mix of
come with a built-in common

regulated output, and supporting up to 10 Switches for MC14-TR+PS9 and 16 units CSG14
Series for MC14-TR+PS9X2. The MC14-TR+PS9X2 Model has two groups of eight units
securing them in the tray and enabling separate removal for service. The dual LEDs permit
TR+PS9, 19” rack-mount tray, holding a few Converter Switches, each with their power
input plugged into the built-in common AC power supply in the rear area of the tray. (PS
Metal mounting screws in the bottom-front hold each of the media converters
per power supply. The power supplies have auto-ranging AC input for use worldwide.
The side-view below is an example of an installation of the model MC14-
units that come with the MC’s are not used).
viewing of Switch status from any angle.

The Magnum CSG14 models with “HR” have 24VDC power, and have the DIN-
It comes with four screws to attach the bracket to the MC unit. The rail clip is
spring-loaded with a pull-up latch at the top for easy “snap-on” attachment and removal.

Rail-MC2 bracket included and assembled with the MC unit at the factory.
A Magnum CSG14H is shown
alongside the DIN-Rail-MC2 bracket
hardware is optional and needs to be ordered as
a separate item, e.g. Model #DIN-RAIL-MC2.
environments, are also available for DIN-Rail
CSG14PR Converter Switches, designed for
mounting in an enclosure having DIN Rails.
use in “Factory Floor” Industrial Ethernet
The metal DIN-Rail mounting
3.4 DIN-Rail mounting option The Magnum CSG14HR and

external AC power supply. Magnum CSG14 Series require a 12VDC input power supply.
withstand higher temperature environments, and provide the DC power choices to the user
The 12V DC power input has a plug of 2.5mm, center +ve , with 6 ft. cord. All
Magnum CSG14 Series Switches are power-efficient and can work with an
the AC power supply info detail is provided in Technical Specifications Section 1.1.
The CSG14 Series are designed to be used with UL listed Class II power
supplies. The CSG14H and CSG14P converter switches provide reliable operation,
The extended temperature (H and P) versions are used for heavy-duty industrial
3.5 Power Requirements for CSG14 Series Switches
to deploy in uncontrolled temperature environments.
applications.

The Direct DC (Internal) 12V DC (8 – 15V DC) has a built-in terminal block for
only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like).
3.6 Powering the CSG14 with 12V, 24V or –48VDC power input Each Magnum CSG14H/CSG14P-Series is reliably equipped with an internal DC
+, -, ground. The 9V DC jack is also present. Detailed information about the 12 VDC, the
Various models of DC power type and extended ambient temperature power supplies are
power supply, and has built-in screw terminals for secure attachment of the power leads.
Three models support a range of power input types. The three model choices are for use
with 12VDC, 24VDC or -48VDC power. DC power input may be chosen for high-
24V DC and the –48V DC is provided in the Technical Specifications Section 1.1.
available. Specify the power supply needed on your order.
availability.



temperature uncontrolled environments, rated at
–40`C to +75`C. If indoors, the DC jack is also
The extended temperature capability
of the DC-powered CSG14P’s can go into
present and optionally can be used with an
connection to the CSG14H chassis
external AC power supply.



Power Consumption: 4 watts typical, 5 watts max.
0.4 amp max.(24V DC)
0.2 amp max.(-48V DC)
3.7 CSG14 Series, DC-powered, -48, 24 and 12VDC Installation This section describes the proper
12VDC leads) to the DC power terminal block on the Magnum CSG14H hardened media
connection of the -48VDC leads (or 24VDC,
terminal block on the Magnum CSG14H is
located on the left side of the unit and is
converter (as shown in Figure). The DC

positive (+) and negative (-), and they are floating inside the unit so that the user if desired
The connection procedure is straightforward. Simply insert the DC leads to the
and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead
equipped with three (3) screw-down lead posts. The power terminals are identified as
(GND) optional; it connects to the CSG14H chassis. Ensure that each lead is securely
CSG14H’s power terminals, positive (+) and negative (-) screws. The use of Ground
may ground either of the terminals. The chassis is “earth” or ground (GND).
will connect to the post-labeled “+ve” and the rest to the “-ve”.
When power is applied, the green PWR LED will illuminate.
tightened from the top, as shown here.
The GND can be hooked up at the last.

used when making 1000BASE-T connections. When the ports are used as 10BASE-T ports,
cabling is 100 meters (328 ft). For fiber port 10BASE-FL, 100BASE-FX or 1000BASE-SX
types i.e. fiber and copper (RJ-45) types, run at 1000BASE-T, 100BASE-TX, 10BASE-T
9/125 microns cabling should be used. Fiber cabling supports much longer cable distance and higher bandwidths as compared to copper wiring.
3.8 Connecting Ethernet Media The Magnum CSG14 Series Converter Switch can be connected to two media
and 1000BASE-SX/LX/ZX, 100BASE-FX, or 10BASE-FL. CAT 5E cables should be
multi-mode, 50/125 or 62.5/125 microns cabling can be used, whereas for single-mode,
CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair
Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45
Twisted Pair (CAT 5) 100BASE-TX RJ-45
Media IEEE Standard Connector
Twisted pair (CAT5E or CAT6) 1000BASE-T RJ-45
Fiber (Multi-mode) 10BASE-FL SC

10Mbps, 100Mbps and 1000Mbps) be used whenever possible in order to provide flexibility in a mixed-speed network, since CSG14 Series switch ports are auto-
or 1000BASE-T twisted pair segment to the RJ-45 port. The procedure is the same for both
sensing for either 10,100 or 1000Mbps. Note that the auto-cross function does
The following procedure describes how to connect a 10BASE-T, 100BASE-TX
3.8.1 Connecting Twisted Pair (RJ-45, CAT 3, CAT 5 or CAT 6, Unshielded or
Fiber (Single-mode) 100BASE-FX SC, LC
Fiber (Multi-mode, Single-mode) 1000BASE-SX SC, LC
not operate, if the port is fixed or not supporting auto-negotiation.
Fiber (Multi-mode) 100BASE-FX SC
Fiber (Single-mode) 1000BASE-LX/ZX LC
unshielded and shielded twisted pair cables.
Shielded)

does not help, ensure that the cable is connected properly and that the device on the
The following procedure applies to installations using LC-type fiber connectors,
simply snap on the two square male connectors into the LC female jacks of the
i.e., using LC single-mode. While connecting fiber media to LC connectors,
3.8.2 Connecting Fiber Optic LC-type, “Small Form factor (SFF)”
shielded, either unshielded or shielded cables and wiring may be used.
Fiber connector until it clicks and secures.
other end is powered and is not defective.

Grasp the SFP module by your thumb and forefinger. Insert the SFP into the SFP
The following procedure applies to installations using SC-type fiber connectors,
simply snap on the two square male connectors into the SC female jacks of the
connectors. Single-mode fiber cable has a smaller diameter than multi-mode
i.e., using multi-mode SC. While connecting fiber media to SC connectors,
slot. Apply a light pressure to the SFP until the device clicks and locks into
fiber cable (9/125 microns for single-mode, 50/125 or 62.5/125 microns for
multi-mode where xx/xx are the diameters of the core and the core plus the
When using single-mode fiber cable, be sure to use single-mode fiber port
cladding respectively). Single-mode fiber allows full bandwidth at longer
The same procedures as for single-mode fiber apply to multi-mode fiber
3.8.4 Installing LC-type SFP module,“Small Form Pluggable (SFP)”
connectors. Follow the steps listed in Section 3.8.3 above.
distances, about 70km with the single-mode LC.
3.8.3 Connecting Fiber Optic SC-type, "Snap-In"
position. Now connect your LC connectors.
Fiber connector until it clicks and secures.
3.8.5 Connecting Single-Mode Fiber Optic

Siemens’) web sites and catalogs to provide guidance to network designers and installers
Receiver Sensitivity and Transmitter Power are the parameters necessary to
where the “Cable Loss” for 62.5/125 and 50/125μm (m.m.) is 2.8 dB/km,
compute the power budget. To calculate the power budget of different fiber media
The following data has been collected from component manufacturer’s (HP’s, and
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
installations using Magnum products, the following equations should be used:
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
3.8.6 Power Budget Calculations for CSG14 Series, Fiber Media
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
OPB (Optical Power Budget) = PT(min) - PR(min)


mode 0.55 850 62.5/125 50/125 -9.5 -17 5.5 2 12.5 4
-mode 10 1310 9/125 -9.5 -20 8.5 17 10.5 21
-mode 25 1310 9/125 -4.0 -21 15 37.5 17.5 43
-mode 40 1550 9/125 -4.0 -21 15 60 17.5 70
-mode 70 1550 9/125 -3.0 -23 18 90 20.5 102
SX 1000Mb SX Multi-
Std.
CSG14-
CSG14-
CSG14-
ZX40
CSG14-
ZX70

NIC to the CSG14 Series, it may be necessary to reload the NIC drivers on the user device
100BASE-TX). When 1000Mb operation is agreed and in use, the Gb LED is illuminated steady ON and is OFF, for 10 or 100Mbps traffic.
* Note: The use of either multi-mode or single-mode fiber to operate at 1000Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following
Fast Link Pulse (FLP) coding for the 1000BASE-T signaling system. When connecting a
The copper ports of Magnum CSG14 Series Converter Switches will function
properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the
if the NIC has been communicating with a protocol other than 1000BASE-T (such as
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
3.8.7 Connections to NICs which support Auto-Negotiation
passive Attenuation.
factors are both applied:

speed, and auto cross for plug polarity. (See Section 2.2). When the connected device is 10
configuring to be done at installation or for maintenance. The only hardware configuration
users can “communicate” with 100Mbps users as well as other 10 Mbps users through the
settings are user options for port #2, to configure it FF/AN. The internal functions of both
4.1 Triple-Speed Functionality, and Switching The Magnum CSG14 Series Converter Switches provide three switched ports.
Mbps, the CSG14s obey all the rules of 10 Mbps Ethernet configurations. The 10 Mbps
Magnum CSG14 Series units are plug-and-play devices. There is no software
The switched RJ-45 ports are full- or half-duplex auto-sensing for mode and
switch. Similarly, the 100Mbps traffic obeys the rules of 100Mbps Ethernet, and can
The architecture supports a triple speed-switching environment, with standard auto-
communicate with 10 Mb and 100Mb users.
negotiation capability.
are described below.

either filter or to forward the packet. Packets whose source and destination addresses lie on
the same port segment, will be filtered, constraining them to one port and relieving the rest
Each time a packet arrives on one of the switched ports, the decision is taken to
ports where it is not needed. Packets needed for maintaining the operation of the network
eliminates bad packets and enables peak performance to be achieved when there is heavy
of the network from processing them. A packet whose destination address is on another
port segment will be forwarded to the appropriate port, and will not be sent to the other
(such as occasional multi-cast packets) are forwarded to all ports. The Magnum CSG14
nodes are added or removed or moved from one segment to another, the CSG14 Series
addresses, and are suitable for use in large networks. They are self-learning, so that as
The Magnum CSG14 Series units have address table capacity of 1K node
Series Converter Switches operate in the store-and-forward switching mode, which
Switching, Filtering and Forwarding
traffic on the network.
Switching, Address Learning

An address-aging algorithm causes least-used addresses to fall out in favor of new
connecting the CSG14’s to other unmanaged switches, legacy hubs, managed switches,
where the switch manager fixes the port settings via software, and the result of the auto-
negotiation is changed in the managed switch by the manager commands. In such cases,
The RJ-45 ports support auto cross (MDI or MDIX) in the auto-negotiation
media-converters etc. Please note that there can be conditions with managed switches
the 10/100/1000 speed or the F/H mode may be affected, but auto-cross in the CSG14
advertises its capability for 10, 100 or 1000Mbps speed and F/H duplex mode, and the
mode according to the IEEE 802.3z standard. No crossover cables are needed when
When an RJ-45 cable connection is made, and each time LINK is enabled,
frequently used addresses. To reset the address buffer, cycle power down-and-up.
auto-negotiation takes place (except for legacy products, which do not have auto-
negotiation and which go to the default state accordingly). The Magnum Switch
Switches will still work. The auto cross function cannot be disabled.
4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing
switch automatically keeps up with node locations.

segment or a loss of power occurs in the unit or remote device. The Link ports
turn off in the event connectivity is lost between the ends of the twisted pair
device at the other end of the cable should similarly advertise / respond. Both sides will
agree to the speed and mode to be used per the IEEE 802.3z standard. Depending upon
LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will
the devices connected, this will result in agreement to operate at 10Mbps, 100Mbps or
Gb Steady ON for 1000Mb speed, OFF for 100Mb or 10Mb speed per port
are also represented by LA1, LA2, and LA3. (Steady On or steady Off
PWR Illuminates GREEN to indicate power applied.
4.3 Dual LEDs, Top-front and in End with ports LED Description
1000Mbps speed, and full- or half-duplex mode.
indicates no Receive Activity).

Switch is not performing as expected, do not attempt to repair the unit; instead contact your
10/100/1000 Mb/s Switches is a straightforward procedure (see INSTALLATION, Section
Should problems develop during installation or operation, this section is intended
to help locate, identify and correct these types of problems. Please follow the suggestions
All Magnum products are designed to provide reliability and consistently high
procedures described in this section or if the Magnum CSG14 Series 10/100/1000 Mb/s
performance in all network environments. The installation of Magnum CSG14 Series
listed below prior to contacting your supplier. However, if you are unsure of the
3.0); the operation is also straightforward and is discussed in Section 4.
supplier for assistance or contact GarrettCom Customer Support.

into a functioning electrical outlet. Use the PWR LEDs to verify each unit is
the problem device is replaced with a known good device. Verify whether or
5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back
to the Installation Section of the applicable chapter of this manual. Also
impaired during installation. (About 90% of network downtime can be
CSG14 Series 10/100/1000 Mb/s switch product, it is recommended that
connected and the cables/wires have not been crimped or in some way
check to make sure that the various components of the network are
CSG14 Series unit. Be certain that the AC power cord is plugged
attributed to wiring and connector problems.)
receiving power.
interoperable.

not the problem is corrected. If not, go to Step 5 below. If the problem is
d. Any particular application that, when used, appears to create the problem;
of the Magnum CSG14 Series 10/100/1000 Mb/s Switch unit or if
corrected, the Magnum CSG14 Series Switch and its associated
unknown, contact GarrettCom, Inc by fax, phone or email
Please be prepared to provide the following information.
(support@garrettcom.com) for assistance.
c. The components involved in the problem;
a. The nature and duration of the problem;
b. Situations when the problem occurs;
cables are functioning properly.
5.2 When Calling for Assistance

including convenient computers, workstations, terminals and printers; plus, the
to the occurrence of the problem. Any changes to system administration
Include the date(s) that you purchased the products from your supplier.
procedures should all be noted in this record.
various network media types being used.

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.
5.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization
(RMA) number. To obtain an RMA number, please use this URL -
Failure symptoms, including a full description of the problem.
Please have the following information readily available:
Name and phone number of your contact person.
Packing List Number (or Sales Order Number)
Name of your company / institution
Serial Number (or Invoice Number)
Your shipping address · Date of installation · Product name

GarrettCom will carefully test and evaluate all returned products, will repair products that
are under warranty at no charge, and will return the warranty-repaired units to the sender
details). However, if GarrettCom cannot duplicate the problem or condition causing the
GarrettCom reserves the right to charge for the testing of non-defective units
under warranty. Testing and repair of product that is not under warranty will result in a
with shipping charges prepaid (see Warranty Information, Appendix A, for complete
No Problem Found.
return, the unit will be returned as:
customer (user) charge.

Should you need to ship the unit back to GarrettCom, please follow these instructions:
or bag for shipping protection. (You may retain all connectors and this
This material may cause electro-static shock damage to the unit.
47823 Westinghouse Drive Fremont, CA 94539
Attn.: Customer Service
5.4 Shipping and Packaging Information
Installation Guide.)

During this warranty period, GarrettCom will repair or, at its option, replace components in
This warranty will not be effective if, in the opinion of GarrettCom, GarrettCom
has damaged by misuse, misapplication, or as a result of service or modification other than
Please complete the warranty card as this acts as a product registration, and mail
GarrettCom, Inc. warrants its products to be free from defects in materials and
the product. GarrettCom reserves the right to make a charge for handling and inspecting
workmanship for a period of three (3) years from the date of shipment by GarrettCom.
the products that prove to be defective at no charge other than shipping and handling,
any product returned for warranty repair which turns out not to be faulty.
provided that the product is returned pre-paid to GarrettCom.
it to GarrettCom within two weeks of your purchase.