EN
GarrettCom logo
Official user manual

GarrettCom CS14

76 pages·778 KB·Switch·PDF·ENDEFRITNLJA
GarrettCom CS14
Table of Contents 80 sections Magnum CS14 and CSN14 Converter Switches · 100Mb Fiber 10 Mb Fiber · Installation and User Guide · CS14, CSN14 Series Converter Switch Installation and User Guide (02/06) · … ShowHide
Magnum CS14 and CSN14 Converter Switchesp.1100Mb Fiber 10 Mb Fiberp.1Installation and User Guidep.1CS14, CSN14 Series Converter Switch Installation and User Guide (02/06)p.2Magnum ™ CS14 and CSN14 Series Converter Switchp.2Radio Frequency Interference Statementp.3Federal Communications Commissionp.3Email: [email protected]p.447823 Westinghouse Drive Fremont, CA 94539p.4Phone (510) 438-9071p.4Fax (510) 438-9072p.4Contacting GarrettCom, Incp.43.7 CS14H and P Series , DC-powered, Installation .............................. 48p.63.8.2 Connecting Fiber Optic ST-type, “twist-lock”........................... 52p.63.8.3 Connecting Fiber Optic SC-type, "Snap-In".............................. 53p.63.8.4 Connecting Single-Mode Fiber Optic........................................ 53p.63.8.5 Power Budget Calculations for CS14 Series, Fiber Media........ 54p.63.8.6 Connections to NICs which support Auto-Neg RJ-45 ports...... 56p.64.1 Dual-Speed Functionality, and Switching ......................................... 57p.64.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing................ 59p.65.3 Return Material Authorization (RMA) Procedure............................. 66p.65.4 Shipping and Packaging Information................................................. 68p.7APPENDIX A: WARRANTY INFORMATION......................................... 69p.7Rev A 07/04: Minor updates on Agency approvals and power suppliesp.7Rev A 05/05: Minor updates on Auto-cross (MDIX) functionalityp.7Rev A 02/06: Change address to Westinghouse Drivep.7Revisionsp.7Filter and Forward Rate from 100Mbps ports: 148,800 pps maxp.8Processing type: Store and Forward, non-blockingp.8When a port is operating at 100Mbps:p.8When a port is operating at 10 Mbps:p.8Data Rate: 10 Mbpsp.8Packet-Processing Between Domainsp.8Auto-learning: 2K address tablep.8Data Rate: 100Mbpsp.81.1 Technical Specificationsp.81.0 SPECIFICATIONSp.8Ports Performancep.8Packet buffers memory: 128KB, dynamically shared on all domainsp.910BASE-T (Unshielded twisted pair) - 100 m (328 ft)p.9100BASE-TX (CAT 5 UTP) - 100 m (328 ft)p.9Cold Start:p.10Operating Environmentp.10Cooling Method:p.11Packaging:p.11AC POWER SUPPLY ( using an external power adapter):p.12Office Ratings (0 to 40°C)p.12POWER SUPPLYp.12Temperature un-controlled Premium(P) Ratings (-40 to 75°C)p.13Factory Floor (H) Ratings (-25 to 60°C)p.13LED Indicators (Dual: front and top)p.16Mounting optionsp.16Agency Approvals and Standards Compliance:p.172.0 INTRODUCTIONp.212.2 Product Descriptionp.22CS14 with 100Mb ST connectorp.26Fig 2.2ap.262.3 Frame Buffering and Latencyp.30LANsp.342.5 Applications for CS14 and CSN14 Series Converter Switchesp.37PLCp.41Example 2: CS14H and CSN14Hp.41UPLINK 3 4 5 6 7 8 1SWp.43POWERp.432SWp.43LK/ACTp.43F/Hp.43GARRETTp.43F H = Xp.43Secure attachment ofp.45clips for panel -p.453.1 Locating the Converter Switch Unitp.453.0 INSTALLATIONp.45Switches, a rack-mount tray isp.47and CSN14 series Converterp.47mounted with the DC powerp.47connectors in the front. Anyp.47mounting of Magnum CS14p.47The Converter Switches arep.47jack in the back, with thep.47
Page 1 of the GarrettCom CS14 user manual — 100Mb Fiber 10 Mb Fiber
Page 1 · click to enlarge
Page 1

Magnum CS14 and CSN14 Converter Switches

GarrettCom CS14 — Magnum CS14 and CSN14 Converter Switches diagram (page 1)
Fig. 1 · Magnum CS14 and CSN14 Converter Switches

100Mb Fiber 10 Mb Fiber

Installation and User Guide

GarrettCom CS14 — 100Mb Fiber 10 Mb Fiber diagram (page 1)
Fig. 2 · 100Mb Fiber 10 Mb Fiber
GarrettCom CS14 — 100Mb Fiber 10 Mb Fiber diagram (page 1)
Fig. 3 · 100Mb Fiber 10 Mb Fiber
Page 2 of the GarrettCom CS14 user manual — Installation and User Guide
Page 2 · click to enlarge
Page 2

CS14, CSN14 Series Converter Switch Installation and User Guide (02/06)

are experienced with Magnum CS14 or CSN14 10/100 Mb/s Converter Switch

Copyright © 2006 GarrettCom, Inc. All rights reserved. No part of this publication may

Magnum ™ CS14 and CSN14 Series Converter Switch

Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.

unauthorized personnel shall render all warranties null and void. If problems

GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch, Converter

be reproduced without prior written permission from GarrettCom, Inc.

Switches contains no user serviceable parts. Attempted service by

products, consult Section 5, Troubleshooting, of this User Guide.

Installation and User Guide

UL is a registered trademark of Underwriters Laboratories

Part #84-00101 Rev. A

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

Printed in the United States of America.

Trademarks

Page 3 of the GarrettCom CS14 user manual — Radio Frequency Interference Statement
Page 3 · click to enlarge
Page 3

CS14, CSN14 Series Converter Switch Installation and User Guide (02/06)

This equipment generates, uses and can radiate frequency energy and if not

installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested and

found to comply with the limits for a Class A computing device in accordance with the

specifications in Subpart J of Part 15 of FCC rules, which are designed to provide

reasonable protection against such interference when operated in a commercial

environment. Operation of this equipment in a residential area is likely to cause

interference, in which case the user, at his own expense, will be required to take

Radio Frequency Interference Statement

Federal Communications Commission

whatever measures may be required to correct the interference.

Page 4 of the GarrettCom CS14 user manual — Contacting GarrettCom, Inc
Page 4 · click to enlarge
Page 4

CS14, CSN14 Series Converter Switch Installation and User Guide (02/06)

Please use the mailing address, phone and fax numbers and email address listed below:

Websitehttp://www.GarrettCom.com

Email: [email protected]

47823 Westinghouse Drive Fremont, CA 94539

GarrettCom, Inc.

Phone (510) 438-9071

Fax (510) 438-9072

Contacting GarrettCom, Inc

Page 5 of the GarrettCom CS14 user manual — Email: support@garrettcom.com
Page 5 · click to enlarge
Page 5
Page 5 of the GarrettCom CS14 user manual — Email: support@garrettcom.com
Page 6 of the GarrettCom CS14 user manual — CS14, CSN14 Series Converter Switch Installation and User Guide (02/06)
Page 6 · click to enlarge
Page 6

4.3 (F- H) Switch, Full-Duplex or Half-Duplex options for Fiber port# 1. 60 4.4 Dual LEDs, Front-panel and side-panel (Magnum CS14 and CSN14)61

CS14, CSN14 Series Converter Switch Installation and User Guide (02/06)

3.7 CS14H and P Series , DC-powered, Installation .............................. 48

3.8 Connecting Ethernet Media ............................................................... 49

3.8.1 Connecting Twisted Pair............................................................ 51

3.8.2 Connecting Fiber Optic ST-type, “twist-lock”........................... 52

3.8.3 Connecting Fiber Optic SC-type, "Snap-In".............................. 53

3.8.4 Connecting Single-Mode Fiber Optic........................................ 53

3.8.5 Power Budget Calculations for CS14 Series, Fiber Media........ 54

3.8.6 Connections to NICs which support Auto-Neg RJ-45 ports...... 56

4.0 OPERATION ....................................................................................... 57

4.1 Dual-Speed Functionality, and Switching ......................................... 57

4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing................ 59

5.0 TROUBLESHOOTING ...................................................................... 62

5.1 Before Calling for Assistance ............................................................ 63

5.2 When Calling for Assistance ............................................................. 65

5.3 Return Material Authorization (RMA) Procedure............................. 66

Page 7 of the GarrettCom CS14 user manual — Revisions
Page 7 · click to enlarge
Page 7

CS14, CSN14 Series Converter Switch Installation and User Guide (02/06)

5.4 Shipping and Packaging Information................................................. 68

APPENDIX A: WARRANTY INFORMATION......................................... 69

Rev A 05/04Initial release of this user manual for CS14 Converter Switches

GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or

Rev A 07/04: Minor updates on Agency approvals and power supplies

Rev A 05/05: Minor updates on Auto-cross (MDIX) functionality

Rev A 09/04: Minor updates on UL requirements, and edit.

Rev A 02/06: Change address to Westinghouse Drive

Rev A 10/04: Minor updates on power supply option.

model offerings without notice.

Revisions

Page 8 of the GarrettCom CS14 user manual — Processing type: Store and Forward, non-blocking
Page 8 · click to enlarge
Page 8

Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.

Filter and Forward Rate from 100Mbps ports: 148,800 pps max

100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3u

Processing type: Store and Forward, non-blocking

When a port is operating at 100Mbps:

When a port is operating at 10 Mbps:

Data Rate: 10 Mbps

Packet-Processing Between Domains

Auto-learning: 2K address table

Data Rate: 100Mbps

1.1 Technical Specifications

1.0 SPECIFICATIONS

Ports Performance

Network Standards

Page 9 of the GarrettCom CS14 user manual — 100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
Page 9 · click to enlarge
Page 9

Packet buffers memory: 128KB, dynamically shared on all domains

10BASE-T (Unshielded twisted pair) - 100 m (328 ft)

Latency (not including packet time): 100 to 10 Mbps: 5µs 10 to 100Mbps: 15µs Path Delay Value: 50 BT on all ports

100BASE-FX, full-duplex(single-mode, long reach) - 40 km (131,240 ft)

100BASE-TX (CAT 5 UTP) - 100 m (328 ft)

100BASE-FX, full-duplex(single-mode) - 20 km (65,620 ft)

10BASE-FL, Single-mode Fiber optic - 10 km (32,810ft)

100BASE-FX, half-duplex(multi-mode) - 412 m (1350 ft)
100BASE-FX, full-duplex(multi-mode) - 2 km (6,562 ft)
100BASE-FX, half-duplex(single-mode) - 412 m (1350 ft)

10BASE-FL, Fiber optic - 2 km (6,562 ft)

Maximum Ethernet Segment (or Domain) Lengths

Address buffer age-out time: 300 sec.

Page 10 of the GarrettCom CS14 user manual — Cold Start:
Page 10 · click to enlarge
Page 10

CS14P, CSN14P: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL).

CS14H, CSN14H: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL).

-40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests.

-58ºF to 212ºF (-50ºC to 100ºC) Short term per IEC Type tests.

Ambient Relative Humidity5% to 95% (non-condensing)
Altitude (All models)-200 to 5000ft. (-60 – 15,000 m)

Conformal Coating (optional) for humidity protection

CS14, CSN1432 º F to 104 º F (0 º C to 40 º C)
All models-40 º F to 160 º F (-40 º C to 85 º C)

Cold Start:

Operating Environment

CS14H, CSN14H to -20ºC

CS14P, CSN14P to -40ºC

altitude.

Storage Temperature,

Page 11 of the GarrettCom CS14 user manual — Cooling Method:
Page 11 · click to enlarge
Page 11

temperature un-controlled location models have closed cases to withstand dirt and use

Convection on the regular model. The hardened (H) factory floor and premium (P)

special thermal techniques to transfer heat to the outside of the case for cooling.

3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x 2.5 cm)

–Hd, and Hi5.8 oz (165g)
–Pd, and -Pi7.9 oz (225g)

Enclosure: Rugged sheet metal (Steel).

Dimensions of the Switch unit:

Power supply, –d, and i5.9 oz (170g)
Weightall models: 4.6 oz. (130g);

Cooling Method:

Packaging:

Page 12 of the GarrettCom CS14 user manual — POWER SUPPLY
Page 12 · click to enlarge
Page 12

All models have an (8-15)VDC output with 6ft long cord and a 2.5mm center +ve jack. The

These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked

500mA).When connected to a 48 V centralized dc source these products shall be provided

“Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output

voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to

power supplies are temperature rated to match the Converter Switch ratings.

North America (-d) models. Input: direct plug-in 95-125vac at 60 Hz.

AC POWER SUPPLY ( using an external power adapter):

with a Listed 5 A DC fuse in the supply circuit.

Office Ratings (0 to 40°C)

Output:12vdc, 1Amps

POWER SUPPLY

Page 13 of the GarrettCom CS14 user manual — Temperature un-controlled Premium(P) Ratings (-40 to 75°C)
Page 13 · click to enlarge
Page 13

North America (-Pd) models. Outdoor temperature rated. Input: 6ft AC power cord to IEC

International (-Hi) models. Factory floor temperature rated. Input: IEC 320 connector on

North America (-Hd) models. Hardened, factory floor temperature rated. Input: 6ft AC

International (-Pi) models. Outdoor temperature rated. Input: IEC 320 connector on the

International (-i) models . Input240vac at 50Hz with IEC 320 connector for the user

power cord to IEC 320 connector on the 100-240vac 47-63Hz external power adapter.

the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord

100-240vac 47-63Hz external power adapter. Requires a user supplied power cord. Output:12vdc, 2Amps.

320 connector on the100-240vac 47-63Hz external power adapter. Output:12vdc, 2Amps.

Temperature un-controlled Premium(P) Ratings (-40 to 75°C)

Factory Floor (H) Ratings (-25 to 60°C)

Output:12vdc, 1.25Amps

Output:12vdc, 1.25Amps.

supplied AC power cord.

Output:12vdc, 1Amps

Page 14 of the GarrettCom CS14 user manual — Temperature un-controlled Premium(P) Ratings (-40 to 75°C)
Page 14 · click to enlarge
Page 14
GarrettCom CS14 — Temperature un-controlled Premium(P) Ratings (-40 to 75°C) diagram (page 14)
Fig. 4 · Temperature un-controlled Premium(P) Ratings (-40 to…
GarrettCom CS14 — Temperature un-controlled Premium(P) Ratings (-40 to 75°C) diagram (page 14)
Fig. 5 · Temperature un-controlled Premium(P) Ratings (-40 to…
GarrettCom CS14 — Temperature un-controlled Premium(P) Ratings (-40 to 75°C) diagram (page 14)
Fig. 6 · Temperature un-controlled Premium(P) Ratings (-40 to…
Direct DC POWER SUPPLYbuilt-in terminal block for +, -, ground along with

the DC terminal block. Power supply protection is provided by internal diodes.

24V DC internal (range of 18 to 36V DC),.

-48V DC internal (range of 36 to 60V DC), , -, ground.

12VDC jack 12V DC internal (range of 8.0 to 15V DC),.

Power Consumption: See Section 3.6.

Page 15 of the GarrettCom CS14 user manual — Temperature un-controlled Premium(P) Ratings (-40 to 75°C)
Page 15 · click to enlarge
Page 15

Two RJ-45 Ports: support 100BASE-TX and 10BASE-T with auto-cross (MDIX).

and on the CS14 series it is 100Base-FX with a “fiber flavor” choice of multimode

One Fiber optic portOn the CSN14 Series it is 10Base-FL with ST connections

The default setting is “F” for 100Mb fiber models, “H” for 10Mb fiber models.

They are shielded 8-pin female connectors for shielded (STP) and unshielded

Fiber Port # 1 is controlled by an “F – H” switch, provided underneath it.

SC, ST or MTRJ or single mode SSC, SSCL, SST or SLC connectors.

“F” enables full-duplex mode and “H” enables half-duplex mode.

(UTP) Cat 3, 4, 5 cable.

Port Connectors:

Switches

Page 16 of the GarrettCom CS14 user manual — LED Indicators (Dual: front and top)
Page 16 · click to enlarge
Page 16

10/100: Steady ON for 100Mbps; OFF for 10 Mbps LK/ACT: Steady ON for LINK (LK) with no traffic, BLINKING indicates

Mean Time Between Failure (MTBF) – over15 years, Telcordia (Bellcore) Method

Rack-mount optionMC14-TRAY, see http://www.garrettcom.com/mc_tray.htm
F/HSteady ON for full-duplex, OFF for half-duplex
DIN-Rail mounting optionModel # DIN-RAIL MC2 (see Section 3.4)

port is transmitting / receiving (ACT).

POWERSteady ON when power applied

Metal mounting clips for panel mounting: included

LED Indicators (Dual: front and top)

Mounting options

Page 17 of the GarrettCom CS14 user manual — Agency Approvals and Standards Compliance:
Page 17 · click to enlarge
Page 17

UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A.

IEC61850 EMC and Operating Conditions Class C Power Substations

WarrantyThree years, return to factory Made in USA
H and P modelsIEEE P1613 Env. Std for Electric Power Substations
P modelsNEMA TS-2 and TEES for traffic control equipment
P modelsdesigned for UL 2043 above-the-ceiling installation

Agency Approvals and Standards Compliance:

NEBS L3 and ETSI compliant.

Page 18 of the GarrettCom CS14 user manual — Agency Approvals and Standards Compliance:
Page 18 · click to enlarge
Page 18

(-25 to 60°C) using a direct DC ( 8-15VDC) and/or external AC hardened power supply (included).

CSN14HR-24VDC = Same as CS14H-24VDC model, but includes DIN-RAIL-MC2 mounting option.

rated (-40 to 75°C) using direct DC (8-15VDC) and/or external AC premium power supply (incl.)

CSN14PR-24VDC = Same as CS14P-24VDC model, but includes DIN-RAIL-MC2 mounting option.

1.2 Summary of models and descriptions: Note: The CSN14 model # consists of the base unit type and the power input. Insert S for sgl-mode

CSN14H-48VDC = Same as CS14H-24VDC model, except -48VDC power input replaces 24VDC.

CSN14P-Pd, Pi = Premium (P), two 10/100 RJ-45+ one 10Mb Fiber port for un-controlled (outdoor)

CSN14H-24VDC = Same as CS14H-12VDC model, except 24VDC power input replaces 12VDC.

CSN14P-24VDC = Same as CS14P-12VDC model, except 24VDC power input replace 12VDC.

The CS14 model # consists of the base unit type, the fiber flavor (ff) and the power input.

CSN14H-12VDC = Same as CS14H model, except AC hardened power supply is not included

CSN14P-12VDC = Same as CS14P-Pd, Pi, except AC Premium Power Supply is not included.

CSN14-d or -i = two 10/100 RJ-45+ one 10Mb ST Fiber port for office and wiring closet,

CSN14H-Hd, Hi = Hardened (H), two RJ-45+ one 10Mb Fiber port for factory floor, rated

CSN14P-48VDC = Same as CS14P-24VDC model, except -48VDC input replaces 24VDC.

rated (0 to 40°C) using an external AC power supply.

CSN14 Models (for 10Mb fiber).

Page 19 of the GarrettCom CS14 user manual — Agency Approvals and Standards Compliance:
Page 19 · click to enlarge
Page 19

CS14P-ff-Pd, Pi = Premium (P), two 10/100 RJ-45+ one 10Mb Fiber port for un-controlled(outdoor)

CS14HR-ff-24VDC = Same as CS14H-24VDC model, but includes DIN-RAIL-MC2 mounting option.

CS14PR-ff-24VDC = Same as CS14P-24VDC model, but includes DIN-RAIL-MC2 mounting option.

(-25 to 60C) using a direct DC ( 8-15VDC) and/or external AC hardened power

CS14H-ff-24VDC = Same as CS14H-12VDC model, except 24VDC power input replaces 12VDC.

CS14H-ff-48VDC = Same as CS14H-24VDC model, except -48VDC power input replaces 24VDC.

CS14P-ff-24VDC = Same as CS14P-12VDC model, except 24VDC power input replace 12VDC.

(-40 to 75C) using direct DC (8-15VDC) and/or external AC premium power

CS14P-ff-12VDC = Same as CS14P-Pd, Pi, except AC Premium Power Supply is not included.

CS14H-ff-12VDC = Same as CS14H model, except AC hardened power supply is not included

CS14-ff-d or -i = two 10/100 RJ-45+ one 10Mb ST Fiber port for office and wiring closet

CS14P-ff-48VDC = Same as CS14P-24VDC model, except -48VDC input replaces 24VDC.

CS14H-ff-Hd, Hi = Hardened (H), two RJ-45+ one 10Mb Fiber port for factory floor

The “ff” field is for selection of the desired “fiber flavor” as listed below.

(0 to 40C) using an external AC power supply.

supply (included).

supply (included).

CS14 Models (for 100Mb fiber).

Page 20 of the GarrettCom CS14 user manual — Agency Approvals and Standards Compliance:
Page 20 · click to enlarge
Page 20

Other Tray configurations with power supplies and power cabling included - See Section 3.3

DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one CS14 and CSN14 Series Switch,

“MTRJ”= 100Base-FX-MTRJ: multi-mode fiber optic with MTRJ type connector, 2km.

“SSCL”= 100Base-FX-SSCL: single-mode fiber optic with SC type connector, 40km.

“SSC”= 100Base-FX-SSC: single-mode fiber optic with SC type connector, 20km.

“SLC”= 100Base-FX-SLC: single-mode fiber optic with LC type connector, 15km.

Conformal Coating (for high humidity and “tropical” applications) - request quote.

MC14-TRAY = 19” Rack-mount tray for 14-series Switch models, up to 16 units

“SC” = 100Base-FX-SC: multi-mode fiber optic with SC type connector, 2km.

“SST” = 100Base-FX-ST: single-mode fiber optic with ST type connector, 2km.

“ST” = 100Base-FX-ST: multi-mode fiber optic with ST type connector, 2km.

See Section 3.4

Accessories

Page 21 of the GarrettCom CS14 user manual — 2.0 INTRODUCTION
Page 21 · click to enlarge
Page 21

1 External Power Supply, (for -d, -i, -Hd, -Hi, -Pd and -Pi models only)

This section describes CS14- and CSN14-Series models, including appearance,

product; notify the carrier immediately of any damage which you believe occurred during

shipment or delivery. Inspect the contents of this package for any signs of damage and

2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this

1 Magnum CS14- or CSN14-Series Converter Switch unit,

1 set Metal panel mounting clips and screws (2 each)

1 User Guide (this manual)

ensure that the items listed below are included.

2.0 INTRODUCTION

features and typical applications.

This package should contain:

Page 22 of the GarrettCom CS14 user manual — 2.2 Product Description
Page 22 · click to enlarge
Page 22

Remove the Magnum CS14 or CSN14 Series Converter Switch from the shipping

container. Be sure to keep the shipping container should you need to ship the unit at a later

date. In the event there are items missing or damaged contact your supplier. If you need to

return the unit, use the original shipping container. Refer to Section 5 Troubleshooting, for

types plus AC or DC input power selection and multiple application environments, and you

The Magnum CS14 and CSN14 family of Converter Switches with a 100 Mb or

(office), Hardened (factory floor), and Premium-rated (outdoor) versions. Extra features for

Combine a 10 or 100 Mb Fiber Media Converter and a two-port 10/100 copper

10Mb Fiber port built in covers the full range of application environments, with regular

product. Add in fiber port choices for all multi-mode and single-mode fiber connector

Switch, and you have the Converter Switch, a flexible edge-of-the-network Ethernet

have the Magnum CS14 and CSN14 Converter Switch family.

specific return procedures.

2.2 Product Description

Page 23 of the GarrettCom CS14 user manual — 2.2 Product Description
Page 23 · click to enlarge
Page 23

Hardened factory-floor and Premium-rated outdoor models. This selection of models and

fiber port types offers the best price-to-value ratio for each user and installation. Where a

The Magnum CS14 and CSN14 regular-package units are for office and indoor

wiring closet environments. These are the economical base units in the CS14 and CSN14

Switch family. An external AC power supply for either North America (-d, 115vac 60Hz)

compact package is ideal for network edge installations, and is able to be conveniently

or international (-I, 230vac, 50Hz) is included. The ambient temperature rating is 0°C to

heavy-duty and extended temperature operation ranges are included selectively in the

Media Converter might have been used, a Converter Switch offers a better value. The

40°C, office grade. A robust metal case with convection cooling is featured. Metal

mounting clips are included, and rack-mount tray options are available.

mounted to suit any application.

Page 24 of the GarrettCom CS14 user manual — 2.2 Product Description
Page 24 · click to enlarge
Page 24

are constructed using special thermal techniques and a metal case for heavy duty industrial

jobs. In addition to a Hardened AC power option and jack, terminals for internal DC power

applications. The CS14H and CSN14H models are built with high-grade components and

choices at 8 to15V, 24V or -48V DC are included. The ambient temperature rating of –25

to 60C is for industrial use. No internal air flow is required for cooling, so it resists dust,

dirt, moisture, smoke and insects. Mounting options include stand-alone panel-mounting,

The Magnum CS14P and CSN14P Premium-rated units are for temperature un-

controlled applications (-40 to 75C), typically located outdoors. The CS14P and CSN14P

models are built with premium-grade extended temperature components, and use similar

thermal techniques as the CS14H Hardened units. In addition to a Premium-rated AC

The Magnum CS14H and CSN14H Hardened units are for factory floor

DIN-Rail, or rack-mount tray.

Page 25 of the GarrettCom CS14 user manual — 2.2 Product Description
Page 25 · click to enlarge
Page 25

LC multi-mode or single-mode. The plug-and-play, energy-efficient, and flavor rich fiber

multiple solutions using very small space. Providing the combination of Media Converter

power option and jack, terminals for internal DC power choices at 8 to15V, 24V or -48V

The CSN14 series provides switching between two 10/100 auto-negotiating copper ports

and one 10Mb ST fiber port and the CS14 series provides switching between two 10/100

auto-negotiating copper ports and one 100Mb fiber port which may be SC, ST, MTRJ or

features make this sleek multi-purpose Switch convenient and cost-effective for the user.

DC are included. When used outdoors, the CS14P should be protected from falling rain.

Mounting options include stand-alone panel-mounting, DIN-rail, or rack-mount tray.

environments and qualify the Converter Switch as a flexible option, which provides

with Switch, the CS14 and CSN14 Series is an ideal choice for edge-of–the-network

The selection of various temperature ranges enable easy deployment in various

applications.

Page 26 of the GarrettCom CS14 user manual — CS14 with 100Mb ST connector
Page 26 · click to enlarge
Page 26

2.2.a) units are for office and wiring closet environments and use an external AC power

supply. A ventilated metal case for convection cooling is featured. Ambient operating

The YELLOW labeled Magnum CS14 and CSN14 models (as shown in Fig

temperature is 0° to 40°C. Storage temperature rating is -40°to 85°C. Metal clips are

GarrettCom CS14 — CS14 with 100Mb ST connector diagram (page 26)
Fig. 7 · CS14 with 100Mb ST connector

included for secure panel mounting.

CS14 with 100Mb ST connector

Fig 2.2a

Page 27 of the GarrettCom CS14 user manual — CS14 with 100Mb ST connector
Page 27 · click to enlarge
Page 27

inflow is required for cooling, so the CS14H and CSN14H resist dust, dirt, moisture, smoke

GarrettCom CS14 — CS14 with 100Mb ST connector diagram (page 27)
Fig. 8 · CS14 with 100Mb ST connector

Ambient operating temperature is –25°C to + 60°C depending on the power source used.

The ORANGE labeled Magnum CS14H and CSN14H hardened units (as shown in Fig

2.2b) are designed for factory floor/Industrial applications. Using special thermal techniques and a sealed rugged metal case for heavy duty industrial applications no air

and insects. Choices of models for external AC or internal DC power are available.

Storage temperature rating is –25°C to + 85°C

CS14H with 100Mb SC connector

Fig 2.2.b

Page 28 of the GarrettCom CS14 user manual — CS14 with 100Mb ST connector
Page 28 · click to enlarge
Page 28

The RED labeled Magnum CS14P and CSN14P series (as shown in Fig. 2.2c) are premium

rated units suitable for temperature un-controlled outdoor applications. Specially designed

with premium-grade extended temperature components, the CS14P and CSN14P units use

+75°C depending on the power source used. Storage temperature rating is between –40°C

include panel-mounting, DIN-rail, or rack-mount tray. Choices of models for external AC

similar thermal techniques to the CS14H hardened units for cooling. Mounting options

or internal DC power are available. Ambient operating temperature is between –40°C to

GarrettCom CS14 — CS14 with 100Mb ST connector diagram (page 28)
Fig. 9 · CS14 with 100Mb ST connector

CS14P with 100Mb SC Connector

to +85°C.

Fig 2.2c

Page 29 of the GarrettCom CS14 user manual — CS14 with 100Mb ST connector
Page 29 · click to enlarge
Page 29

The front side of the unit has two twisted-pair 10/100Mb switch ports and one 10 or 100Mb

fiber port. Both the RJ-45 ports of the CS14 and CSN14 Series Converter switches support

connected correctly and showing, by blinking, when there is traffic. The LK/ACT LED’s

are repeated on the front as LA1 (port 1), LA2 (port 2), and LA3 (port 3). There is a power

Two sets of LEDs to indicating the operating status of ports are mounted on the

top and front (for extra viewing advantage while rack-mounted). For each port, there are

The single fiber port on the CSN14’s is multi-mode with an ST connector and ,

auto-cross (MDIX) operation performing the auto-cross function under auto-negotiation

mode only. The 10Mb fiber (CSN14 models) are factory configured at Half-duplex, and

on the CS14’s, it is an SC, ST or small form-factor connector (MTRJ multi mode or LC

Link and Activity (LK/ACT) LED’s on the top indicating that the media cables are

(PWR) indicator on the front of the unit to validate that the unit is turned ON.

100Mb (CS14 models) are factory configured at Full-Duplex.

Page 30 of the GarrettCom CS14 user manual — 2.3 Frame Buffering and Latency
Page 30 · click to enlarge
Page 30

length and have the correct CRC, i.e. they are good packets. This eliminates propagation of

the fiber port allows the user to fix the fiber port at Full or Half Duplex mode as required.

The Magnum CS14 and CSN14 Series Converter Switches are store-and-forward

switches. Each frame (or packet) is loaded into the Switch’s memory and inspected before

single-mode). The Full Duplex/Half Duplex (“F- H”) manual switch provided underneath

The external DC power plug connector and/or “jack” and the internal DC input

forwarding can occur. This technique ensures that all forwarded frames are of a valid

bad packets, enabling all of the available bandwidth to be used for valid information.

terminal is provided on the rear of the unit.

2.3 Frame Buffering and Latency

Page 31 of the GarrettCom CS14 user manual — 2.3 Frame Buffering and Latency
Page 31 · click to enlarge
Page 31

from 128Kb memory pool, ensuring that heavily used ports receive very large buffer space

While other switching technologies such as "cut-through" or "express" impose

minimal frame latency, they will also permit bad frames to propagate out to the Ethernet

there is no way to filter frames with a bad CRC (the entire frame must be present in order

traffic congestion, especially at peak activity. Since collisions and bad packets are more

which are a result of late collisions, to be forwarded to add to the network traffic. Since

for CRC to be calculated), the result of indiscriminate cut-through forwarding is greater

Magnum CS14 and CSN14 Series Converter Switch dynamically allocates buffer space

for packet storage. (Many other switches have their packet buffer storage space divided

segments connected. The "cut-through" technique permits collision fragment frames,

likely when traffic is heavy, the result of store-and-forward operation is that more

To minimize the possibility of dropping frames on congested ports, each

bandwidth is available for good packets when the traffic load is greatest.

Page 32 of the GarrettCom CS14 user manual — 2.3 Frame Buffering and Latency
Page 32 · click to enlarge
Page 32

provides the capability for the maximum resources of the Magnum CS14 and CSN14 Series

port and in aggregate density, the Magnum CS14 and CSN14 Series Converter Switches are

evenly across all ports, resulting in a small, fixed number of packets to be stored per port.

unit to be applied to all traffic loads, even when the traffic activity is unbalanced across the

ports. Since the traffic on an operating network is constantly varying in packet density per

When the Switch detects that its free buffer queue space is low, the Switch sends

buffering and processing resumes. This flow-control sequence occurs in a small fraction of

industry standard (full-duplex only) PAUSE packets out to the devices sending packets to

which allows a traffic catch-up to occur without dropping packets. Then, normal packet

constantly adapting internally to provide maximum network performance with the least

cause “flow control”. This tells the sending devices to temporarily stop sending traffic,

When the port buffer fills up, dropped packets result.) This dynamic buffer allocation

a second and is transparent to an observer. See Section 4.6 for additional details.

dropped packets.

Page 33 of the GarrettCom CS14 user manual — 2.3 Frame Buffering and Latency
Page 33 · click to enlarge
Page 33

Switches is a collision-based flow-control mechanism (when operating at half-duplex only).

frames from entering by forcing a collision signal on all receiving half-duplex ports in order

forwarded to its destination) of the CS14 and CSN14 Series Converter Switches varies with

When the Switch detects that its free buffer queue space is low, the Switch prevents more

forwarding, the latency is 15 microseconds plus the packet time at 10 Mb. For 100Mb-to-

Another feature implemented in Magnum CS14 and CSN14 Series Converter

The latency (the time the frame spends in the Switch before it is sent along or

the port-speed types. The length of the frame is a variable as it is with all store-and-

forward switches. For 10 Mb-to-10 Mb or 10 Mb-to-100Mb or 100Mb-to-10 Mb

100Mb forwarding, the latency is 5 microseconds plus the packet time at 100Mb.

to stop incoming traffic.

Page 34 of the GarrettCom CS14 user manual — LANs
Page 34 · click to enlarge
Page 34

2.4 Features and Benefits „ Full 100Mb or 10 Mb switching services for high performance Ethernet

Magnum CS14 and CSN14 Series Switches provide Fast Ethernet switching

efficiently and inexpensively connect a Twisted Pair and fiber network with

converter Designed as a multi-purpose media converter and Switch, the 10

traffic, giving each port’s segment a full 100Mb (or 10 Mb) of bandwidth.

or 100Mb fiber port allows the user to convert the media from copper to

fiber and the other RJ-45 port can be used as diagnostic port or for more

on all ports. They perform high speed filter/forward operations on the

Magnum CS14 and CSN14 Series Switches offer the ideal solution to

10Mb or 100Mb and help to expand the Ethernet network in a very convenient and economical way.

„ Choice of 10 or 100Mb Fiber option, more efficient than media

„ Reduces Network Costs and provide economical solution

connectivity.

LANs

Page 35 of the GarrettCom CS14 user manual — LANs
Page 35 · click to enlarge
Page 35

(front and top) of LEDs to provide status information when viewed at almost

switches, only forwarding those packets from each domain that are needed

Each CS14 and CSN14 Series Converter Switch is equipped with two sets

rugged sheet metal enclosure to ensure high reliability and durability even

on the other domains. Internal address tables are self-learning, enabling

any angle or mounting arrangement whether rack (MC14- Tray) or wall-

CS14 and CSN14 Series have a robust design and are packaged in a

„ Installation is “Plug and Play”, operation is transparent to software

The Magnum CS14 and CSN14 Series Switches operate as hardware

users to change port connections or 10/100 domains without affecting

„ Two sets of LEDs for viewing status from any angle.

when placed in industrial or outdoor applications.

„ Rugged metal case, Industrial grade

operations.

mounted.

Page 36 of the GarrettCom CS14 user manual — LANs
Page 36 · click to enlarge
Page 36

for DC models and qualify for temperature un-controlled “outdoor” application.

supply, Magnum CS14 and CSN14 Series of Converter Switches can be installed

in small spaces in cabinets, on table tops, in racks, wall or DIN rail mounted and

„ Qualified to use for temperature un-controlled “outdoor” application

Converter Switches have an ambient temperature rating between –40C to +75C

Featuring a compact steel case with an external AC and internal DC power

All the Magnum CS14 and CSN14 Series Switches are featured with MDIX

(auto-cross), which easily allow cascading with other Switch Hubs or media

„ Efficient Compact design, for all purpose convenient mounting

The Magnum CS14P and CSN14P Premium rated versions of

„ MDIX ports to eliminate cross-over cable while cascading

converters, without using the cross-over cable.

in trays such as the Magnum MC14-TRAY.

Page 37 of the GarrettCom CS14 user manual — 2.5 Applications for CS14 and CSN14 Series Converter Switches
Page 37 · click to enlarge
Page 37

Enriched with the three tier “Y-O-R” hardness rating flavors (Yellow - “office”, Orange –

“Hardened”, Red- “Premium rated (outdoor)”), the multifunctional, multi-media and multi-

almost any environment enabling users to scale their networks quickly and cost effectively.

tools in the modern life of fast expanding network requirements. The Dual-Speed and Dual-

media functions support a mixed environment of 10 Mbps and 100Mbps users with copper

The edge-of-the-network connectivity solutions offered by Magnum Converter Switches

are focused on providing easier, more economical and ultra-reliable industrial application

bandwidth performance. The up-link choice of 10 or 100Mb fiber on Port# 1 enables easy

products. The compactly designed Magnum CS14 and CSN14 Series act as very useful

and fiber media. The switched full / half duplex capability on fiber ports provides high

environmental, Magnum CS14 and CSN14 Series Converter Switches fit very well in

2.5 Applications for CS14 and CSN14 Series Converter Switches

Page 38 of the GarrettCom CS14 user manual — 2.5 Applications for CS14 and CSN14 Series Converter Switches
Page 38 · click to enlarge
Page 38

copper, and also easily solve long distance requirements. The ruggedness of the CS14P’s

availability of all of the industry standard fiber connectors, enable easy interfacing with

existing cable plant and equipment. The Magnum CS14Ps and CSN14Ps fit very well in

effectively. With its half / full duplex switching capability on fiber port # 1, the CS14Ps

steel case and the high reliability of the design compliments the temperature controlled

provide a very economical high bandwidth solution at each cable user access point of

negotiating copper ports together with the 10 or 100Mbps fiber port choices and the

high temperature locations experiencing a need to scale the LAN quickly and cost

expansion for the on-going demand of Ethernet networks. The 10/100Mbps auto-

packaging to provide an exceptional Ethernet product.

Page 39 of the GarrettCom CS14 user manual — 2.5 Applications for CS14 and CSN14 Series Converter Switches
Page 39 · click to enlarge
Page 39
GarrettCom CS14 — 2.5 Applications for CS14 and CSN14 Series Converter Switches diagram (page 39)
Fig. 10 · 2.5 Applications for CS14 and CSN14 Series Converter…

CS14P Convenient Switches provided a secure dependable,

reliable solution for un-controlled temp. environment

M a g n u m m P 6 2

Example1. Indoor Office CS14 or CSN14

W W W .G a r r e t t C o m .C o m

W W W .G a r r e ttC om .C o m

M a g n u m m P 6 2

W W W .G a r re ttC om .C om

Test computer · IBM Compatible

Page 40 of the GarrettCom CS14 user manual — 2.5 Applications for CS14 and CSN14 Series Converter Switches
Page 40 · click to enlarge
Page 40

CS14 or CSN14 Converter Switch. Additional functionality includes the ability to transfer

demand to grow the network. This need can be easily met using the economical Magnum

data across large distances with multi- or single–mode fiber while securing the LAN from

In this example, the indoor office location is a Data Mining function with an ongoing

EMI and wire tapping.

Page 41 of the GarrettCom CS14 user manual — PLC
Page 41 · click to enlarge
Page 41
GarrettCom CS14 — PLC diagram (page 41)
Fig. 11

W W W . G a r r e ttC o m .C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

CS14H Converter Switches provided a secure economical

solution for expanding Industrial network

W W W .G a rr e ttC o m .C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PLC

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

Example 2: CS14H and CSN14H

W W W .G a r r e ttC o m . C o m

PLC

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

W W W . G a r r e ttC o m .C o m

Page 42 of the GarrettCom CS14 user manual — PLC
Page 42 · click to enlarge
Page 42

Magnum CS14H or CSN14H is typically used. . The Fiber port on the converter switches is

Ethernet ports to carry status and control data to the control center the hardened version of

techniques and having no openings for dirt to enter, the CS14 and CSN14 Series Converter

In this application, where in expanding an industrial network environment, the new PLC

ideal for secure data communications over long distances that may be encountered in this

units are deployed on an existing network and each needs one (or two for redundancy)

edge of network application. Built with high-grade components, efficient cooling

Switches provide the very effective solution for this need.

Page 43 of the GarrettCom CS14 user manual — F H = X
Page 43 · click to enlarge
Page 43
GarrettCom CS14 — UPLINK 3 4 5 6 7 8 1SW diagram (page 43)
Fig. 12

W W W .G a rr e ttC om .C om

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

Tx Rx UPLINK Tx Rx UPLINK and Workstations 100Mb Servers 100

W W W .G a r r e tt C o m .C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

Example 3CS14P or CSN14P

W W W .G a r r e tt C o m .C o m

W W W .G a r r e t t C o m . C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

UPLINK 3 4 5 6 7 8 1SW

UPLINK 3 4 5 6 7 8 1SW

UPLINK 3 4 5 6 7 8 1SW

Port 1 Port 2 Port 3

W W W .G a r r e tt C o m .C o m

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

PORTS 1SW 2SW 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

POWER

2SW

2SW

2SW

and Workstations 100Mb Servers 100

and Workstations 100Mb Servers 100

and Workstations 100Mb Servers 100

and Workstations 100Mb Servers 100

and Workstations 100Mb Servers 100

and Workstations 100Mb Servers 100

LK/ACT

F/H

12 Vdc 0.5 Amp

F/H

F/H

F/H

GARRETT

GARRETT

GARRETT

Tx Rx UPLINK Tx Rx UPLINK

F H = X

F H = X

F H = X

Show 19 more labels / short text on this page
CCTV Camera · GarrettCom · Personal Hub · Personal Hub · Personal Hub · 10/100 · Link/Act Speed · Link/Act Speed · Link/Act Speed · Power · Power · Power · Error · Error · Error · Tx Rx UPLINK · Tx Rx UPLINK · Tx Rx UPLINK · Tx Rx UPLINK
Page 44 of the GarrettCom CS14 user manual — UPLINK 3 4 5 6 7 8 1SW
Page 44 · click to enlarge
Page 44

motion detectors or will act as a test port for maintenance personnel with up-link for access

cameras may be spread out over many miles in temperature un-controlled locations and

with pan, tilt and zoom (PTZ) controlled through an Ethernet copper port .The premium

Converter Switches are ideally suited to providing copper to fiber media conversion for

controlled cabinets and allowing a full range of AC and DC power options. The second

copper port at the remote location provides access for other Ethernet equipment such as

secure long distance (2-40km) communication while being installed in temperature un-

deployed to serve as a secure corporate or transportation surveillance system. CCTV

In this example, the Magnum CS14P or CSN14P premium Converter Switches are

to a central LAN and central file servers.

Page 45 of the GarrettCom CS14 user manual — 3.0 INSTALLATION
Page 45 · click to enlarge
Page 45

This section describes the installation of the Magnum CS14 and CSN14 Series

Converter Switches, including location, mountings, power supply options and media

Secure attachment of

clips for panel -

takes care of network traffic and can be used

3.1 Locating the Converter Switch Unit

operate in transparent half-and full-duplex

mode. The store and forward switch easily

All the CS14 and CSN14 Series Switches

as a useful, economical tool to expand an

3.0 INSTALLATION

existing network.

connection.

Page 46 of the GarrettCom CS14 user manual — Secure attachment of
Page 46 · click to enlarge
Page 46

mounting the unit on a vertical surface such as a wall or cabinet, or for securing the unit on

procedure. The installation location is dependent upon the physical layout of the Ethernet

Installation of the Magnum CS14 and CSN14 Series Converter Switches is a simple

network and associated cabling. Make sure the unit is installed in a location that is easily

The compact and lightweight design of the Magnum CS14 and CSN14 Series

accessible to an AC power outlet or the appropriate DC source and where cooling is not

allows it to be easily installed in almost any location. A Velcro strip may be used for

a table-top or shelf. Alternatively, metal mounting clips and screws are included for a

inhibited. The green Power (PWR) LED must turn ON when power is applied.

rugged and secure mounting in any orientation.

Page 47 of the GarrettCom CS14 user manual — mounted with the DC power
Page 47 · click to enlarge
Page 47
GarrettCom CS14 — Switches, a rack-mount tray is diagram (page 47)
Fig. 13 · Switches, a rack-mount tray is

Converters may be placed on a tray, up to a maximum of 16 units. (The mounting

spaces of the MC14-TRAY are specific to the Magnum products and will not

3.2 MC14-TRAY for Rack Mounting of CS14 and CSN14 Series Switches For 19” rack-

permit other models to be properly mounted).

Switches, a rack-mount tray is

and CSN14 series Converter

available, the MC14-TRAY.

mounted with the DC power

connectors in the front. Any

mounting of Magnum CS14

The Converter Switches are

jack in the back, with the

Switches and/or Media

mix of the Converter

fiber and the RJ-45

Page 48 of the GarrettCom CS14 user manual — 3.3 MC14-TR+PS9 and MC14-TR+PS9X2 for Rack Mounting Media Converters
Page 48 · click to enlarge
Page 48

bottom-front hold the Converter Switches firmly in place. The beveled-top edge of the units

The MC14-TR+ PS9 and MC14-TR+PS9X2 are other options for rack mounting the mix of

19” rack-mount tray. These models come with built-in common universal AC power supply

eight) CS14 and CSN14 Series Converter Switches, with their power supplies plugged into

permits the LEDs of each unit to be viewed for operational status, even when the units are

In a typical installation, the MC14-TRAY, 19” rack-mount tray will hold a few (three to

Magnum 10Mbps and 100Mbps Converter Switches and Media Converters together in a

MC14-TR+PS9 and 16 units CS14 and CSN14 Series for MC14-TR+PS9X2. The MC14-

3.3 MC14-TR+PS9 and MC14-TR+PS9X2 for Rack Mounting Media Converters

rated at 55 watts at 50°C ambient, 12VDC output, and supporting up to 10 Switches for

power strips (not included) in the rear area of the tray. Metal mounting screws in the

very close together.

Page 49 of the GarrettCom CS14 user manual — Switches, a rack-mount tray is
Page 49 · click to enlarge
Page 49

common AC power supply in the rear

TR+PS9X2 Model has two groups of eight units per power supply. The power supplies

have auto-ranging AC input for use

The side-view below is an example

Converters, each with their power

of an installation of the model

tray, holding a few CS14 and

CSN14, FT14 and 14E Media

input plugged into the built-in

area of the tray. (PS units that come with the MC’s are not used).

worldwide.

GarrettCom CS14 — Switches, a rack-mount tray is diagram (page 49)
Fig. 14 · Switches, a rack-mount tray is

MC14-TR+PS9, 19” rack-mount

Page 50 of the GarrettCom CS14 user manual — A Magnum CS14H is shown
Page 50 · click to enlarge
Page 50

securing them in the tray and enabling separate removal for service. The dual LEDs permit

The metal DIN-Rail mounting hardware is optional and needs to be ordered as a

GarrettCom CS14 — Switches, a rack-mount tray is diagram (page 50)
Fig. 15 · Switches, a rack-mount tray is

It comes with four screws to attach the bracket to the MC unit. The rail clip is

spring-loaded with a pull-up latch at the top for easy “snap-on” attachment and removal.

Metal mounting screws in the bottom-front hold each of the media converters

DIN-Rail mounting in an enclosure having DIN

3.4 DIN-Rail mounting option The Magnum CS14HR, CSN14HR

and CS14PR, CSN14PR Converter Switches,

designed for use in “Factory Floor” Industrial

separate item, e.g. Model #DIN-RAIL-MC2.

Ethernet environments, are also available for

viewing of Switch status from any angle.

A Magnum CS14H is shown

alongside the DIN-Rail-MC2 bracket

Rails.

Page 51 of the GarrettCom CS14 user manual — 3.5 Power Requirements, Power Supply Types for CS14 and CSN14 Series Switches
Page 51 · click to enlarge
Page 51

The Magnum CS14 and CSN14 models with “HR” have 24VDC power, and have

power supplies. The CS14P/S14H converter switches provide reliable operation, withstand

3.5 Power Requirements, Power Supply Types for CS14 and CSN14 Series Switches

external AC power supply. Magnum CS14 and CSN14 Series require a nominal 12VDC

The 12V DC power input has a plug of 2.5mm, center +ve , with 6 ft. cord. All the AC

Magnum CS14 and CSN14 Series Switches are power-efficient and can work with an

The CS14 and CSN14 Series are designed to be used with UL listed Class II

the DIN-Rail-MC2 bracket included and assembled with the MC unit at the factory.

input version. The extended temperature (H and P) versions are used for heavy duty

power supply info detail is provided in Technical Specifications Section 1.1.

industrial applications.

Page 52 of the GarrettCom CS14 user manual — 12VDC 24VDC -48VDC
Page 52 · click to enlarge
Page 52

higher temperature environments, and provide the DC power choices to the user to deploy

ground. The 9V DC jack is also present. Detail information about the 12 VDC, the 24V DC

only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like).

and the –48V DC is provided in the Technical Specifications Section 1.1.

The various models of DC power type and extended ambient temperature power

The Direct DC (Internal) 12V DC (8 – 15V DC) has a built-in terminal block for +, -,

supplies are numerous and your choice needs to be called out on your order.

12VDC 24VDC -48VDC

in uncontrolled temperature environments.

Page 53 of the GarrettCom CS14 user manual — Switches, a rack-mount tray is
Page 53 · click to enlarge
Page 53

temperature uncontrolled environments, rated at –40`C to +75`C. If indoors, the DC jack is

3.6 Powering the CS14H, CSN14H and CS14P, CSN14P (DC internal) with 12V, 24V or –48VDC power input

GarrettCom CS14 — Switches, a rack-mount tray is diagram (page 53)
Fig. 16 · Switches, a rack-mount tray is

The extended temperature capability of the DC-powered CS14P’s can go

also present and optionally can be used with an external AC power supply.

12VDC, 24VDC or -48VDC power. DC power

is reliably equipped with an internal DC power

models support a range of power input types.

secure attachment of the power leads. Three

supply, and has built-in screw terminals for

input may be chosen for high-availability.

The three model choices are for use with

Each Magnum CS14H/CS14P-Series

Page 54 of the GarrettCom CS14 user manual — 18 – 36V DC (24V DC)
Page 54 · click to enlarge
Page 54
GNDTerminal for “earth” or ground wire connection to the CS14H chassis

Power Consumption: 4.8 watts typical, 6 watts maxm.

36 – 60V DC (-48V DC)

0.4 amp max.(24V DC)

0.2 amp max.(-48V DC)

Input Voltage8 - 15V DC (12V DC)

18 – 36V DC (24V DC)

Input current0.8 amp.(12V DC)
DC Power Terminals“+”, “-”, gnd
Page 55 of the GarrettCom CS14 user manual — 3.7 CS14H and P Series , DC-powered, -48VDC, 24VDC and 12VDC Installation
Page 55 · click to enlarge
Page 55
GarrettCom CS14 — Switches, a rack-mount tray is diagram (page 55)
Fig. 17 · Switches, a rack-mount tray is

CS14H’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND)

This section describes the proper connection of the -48VDC leads (or 24VDC,

The connection procedure is straightforward. Simply insert the DC leads to the

3.7 CS14H and P Series , DC-powered, -48VDC, 24VDC and 12VDC Installation

grounded by the user if desired. The chassis is “earth” or ground (GND).

the Magnum CS14H hardened media converter (as

inside the unit so that either of the terminal may be

12VDC leads) to the DC power terminal block on

shown in Figure ). The DC terminal block on the

Magnum CS14H is located on the left side of the

lead posts. The power terminals are identified as

positive (+) and negative (-), and they are floating

unit and is equipped with three (3) screw-down

Page 56 of the GarrettCom CS14 user manual — Switches, a rack-mount tray is
Page 56 · click to enlarge
Page 56

optional; it connects to the CS14H chassis. Ensure that each lead is securely tightened from

3.8 Connecting Ethernet Media The Magnum CS14 and CSN14 Series Converter Switch can be connected to two

100BASE-FX, or 10BASE-FL. CAT 5 cables should be used when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used. In either

case, the maximum distance for unshielded twisted pair cabling is 100 meters (328 ft). For

and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead

media types i.e. fiber and copper (RJ-45) types, runt at 100BASE-TX, 10BASE-T and

will connect to the post labeled “+ve” and the rest to the “-ve”.

When power is applied, the green PWR LED will illuminate.

The GND can be hooked up at the last.

the top, as shown here.

Page 57 of the GarrettCom CS14 user manual — Switches, a rack-mount tray is
Page 57 · click to enlarge
Page 57

mixed-speed network, since P80-series switch ports are auto-sensing for either 10

can be used, whereas for single-mode, 9/125 microns cabling should be used. Fiber cabling

supports much longer cable distance and higher bandwidths as compared to copper wiring.

fiber port 10BASE-FL or 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling

and 100Mbps. Note that the auto-cross function does not operate, if the port is

Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45

and 100Mbps) be used whenever possible in order to provide flexibility in a

Twisted Pair (CAT 5) 100BASE-TX RJ-45

Media IEEE Standard Connector

Fiber (Multi-mode) 100BASE-FX ST, SC

Fiber (Single-mode) 100BASE-FX SC, LC

Fiber (Multi-mode) 100BASE-FX MTRJ

Fiber (Multi-mode, Single -mode) 10BASE-FL ST

fixed or not supporting auto-negotiation.

Page 58 of the GarrettCom CS14 user manual — Shielded)
Page 58 · click to enlarge
Page 58

The following procedure describes how to connect a 10BASE-T or 100BASE-TX

twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and

does not help, ensure that the cable is connected properly and that the device on the

1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded,
2. Connect the other end of the cable to the corresponding device. 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established. If this
4. For Port # 1 or 1SW, if the LINK LED is not illuminated, move the switch which has a cross-over or up-link for linking to another hub or Switch.

3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or

either unshielded or shielded cables and wiring may be used.

other end is powered and is not defective.

shielded twisted pair cables.

Shielded)

Page 59 of the GarrettCom CS14 user manual — 3.8.2 Connecting Fiber Optic ST-type, “twist-lock”
Page 59 · click to enlarge
Page 59
4. Connect the Receive (RX) port (dark colored post) to the Transmit (TX) port of the

connection has been established at both ends (and when power is ON in the unit). If

2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue
3. Connect the Transmit (TX) port (light colored post) on the Magnum Fiber port to

the Receive (RX) port of the remote device. Begin with the color-coded strand of

The following procedure applies to installations using ST-type fiber connectors.

1. Before connecting the fiber optic cable, remove the protective dust caps from the

dampened in alcohol. Make certain the connectors are clean before connecting.

5. The LINK LED on the front of the fiber connector will illuminate when a proper

at regular intervals; you must use the color-coded strand on the associated

This procedure applies to ports using multi-mode ST fiber connectors.

3.8.2 Connecting Fiber Optic ST-type, “twist-lock”

remote device. Use the non-color coded fiber strand for this.

ports at each end of the fiber optic segment.

the cable for this first TX-to-RX connection.

Page 60 of the GarrettCom CS14 user manual — 3.8.4 Connecting Single-Mode Fiber Optic
Page 60 · click to enlarge
Page 60

LINK is not lit after cable connection, the normal cause is improper cable polarity.

The following procedure applies to installations using SC-type fiber connectors,

i.e., using multi-mode SC and SC single-mode. While connecting fiber media to

connectors. Single-mode fiber cable has a smaller diameter than multi-mode

fiber cable (9/125 microns for single-mode, 50/125 or 62.5/125 microns for

multi-mode where xx/xx are the diameters of the core and the core plus the

SC connectors, simply snap on the two square male connectors into the SC

When using single-mode fiber cable, be sure to use single-mode fiber port

cladding respectively). Single-mode fiber allows full bandwidth at longer

The same procedures as for multi-mode fiber apply to single-mode fiber

Swap the fiber cables at the fiber connector to remedy this situation.

female jacks of the Fiber connector until it clicks and secures.

connectors. Follow the steps listed in Section 3.8.2 above.

3.8.3 Connecting Fiber Optic SC-type, "Snap-In"

distances, about 20Km with the multi-mode SC.

3.8.4 Connecting Single-Mode Fiber Optic

Page 61 of the GarrettCom CS14 user manual — 3.8.5 Power Budget Calculations for CS14 and CSN14 Series, Fiber Media
Page 61 · click to enlarge
Page 61

3.8.5 Power Budget Calculations for CS14 and CSN14 Series, Fiber Media

Siemens’) web sites and catalogs to provide guidance to network designers and installers

Receiver Sensitivity and Transmitter Power are the parameters necessary to

compute the power budget. To calculate the power budget of different fiber media

The following data has been collected from component manufacturer’s (HP’s, and

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

installations using Magnum products, the following equations should be used:

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

where the “Cable Loss” for 62.5/125 and 50/125µm (m.m.) is 2.8 dB/km,

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

OPB (Optical Power Budget) = PT(min) - PR(min)

Page 62 of the GarrettCom CS14 user manual — CSN14-
Page 62 · click to enlarge
Page 62
GarrettCom CS14 — Switches, a rack-mount tray is diagram (page 62)
Fig. 18 · Switches, a rack-mount tray is

-31 9.0 5.5 2.5 2.0 14 12 5 4

mode 20 (0.4) 1300 9/125 -15 -31 14 28 17.5 35

-31 9.0 5.5 3.0 2.0 15.8 12.2 5.5 4.0

mode 40 (0.4) 1300 9/125 -5 -34 27 54 32.5 65

mode 10 (5) 1300 9/125 -30 -39 7 14 13 26

CSN14-

CSN14-

CS14-

CS14-

MTRJ

Show 5 more labels / short text on this page
CS14-SSC 100Mb · Long Reach 100Mb · Module · Fiber · Port
Page 63 of the GarrettCom CS14 user manual — 3.8.6 Connections to NICs which support Auto-Negotiation, RJ-45 ports
Page 63 · click to enlarge
Page 63

Fast Link Pulse (FLP) coding for the 100BASE-TX signaling system. When connecting a

NIC to the CS14-Series, it may be necessary to reload the NIC drivers on the user device if

10BASE-T). When 100Mb operation is agreed and in use, the 10/100 LED is illuminated steady ON and is OFF, if 10 Mbps traffic.

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following

3.8.6 Connections to NICs which support Auto-Negotiation, RJ-45 ports

  • The worst-case OPB of the fiber link must be greater than the fiber cable’s

properly with NICs (Network Interface Cards) which support Auto-Negotiation, and the

The copper ports of Magnum CS14-Sereis Converter Switches will function

  • The 100Mb fiber segment must operate in full-duplex (FDX) mode, and

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

the NIC has been communicating with a protocol other than 100BASE-TX (such as

passive Attenuation.

factors are both applied:

Page 64 of the GarrettCom CS14 user manual — 4.0 OPERATION
Page 64 · click to enlarge
Page 64

The Magnum CS14 and CSN14 Series Converter Switches provide four

speed, and auto-cross for plug polarity. (See Section 2.2). When the connected device is 10

users can “communicate” with 100Mbps users as well as other 10 Mbps users through the

Magnum CS14 and CSN14 Series units are plug-and-play devices. There is no

switched ports (three ports in the front and one on the rear). The architecture supports a

Mbps, the CS14s obeys all the rules of 10 Mbps Ethernet configurations. The 10 Mbps

The switched RJ-45 ports are full- or half-duplex auto-sensing for mode and

software configuring to be done at installation or for maintenance. The only hardware

switch. Similarly, the 100Mbps traffic obeys the rules of 100Mbps Ethernet, and can

dual speed switching environment, with standard auto-negotiation capability.

4.1 Dual-Speed Functionality, and Switching

communicate with 10 Mb and 100Mb users.

4.0 OPERATION

Page 65 of the GarrettCom CS14 user manual — Switching, Filtering and Forwarding
Page 65 · click to enlarge
Page 65

the same port segment will be filtered, constraining them to one port and relieving the rest

(such as occasional multi-cast packets) are forwarded to all ports. The Magnum CS14 and

CSN14 Series Converter Switches operate in the store-and-forward switching mode, which

Each time a packet arrives on one of the switched ports, the decision is taken to

either filter or to forward the packet. Packets whose source and destination addresses on

ports where it is not needed. Packets needed for maintaining the operation of the network

of the network from processing them. A packet whose destination address is on another

port segment will be forwarded to the appropriate port, and will not be sent to the other

configuration settings is user options for port #2, to configure it FF/AN. The internal

Switching, Filtering and Forwarding

functions of both are described below.

Page 66 of the GarrettCom CS14 user manual — Switching, Address Learning
Page 66 · click to enlarge
Page 66

nodes are added or removed or moved from one segment to another, the CS14- and CSN14-

An address-aging algorithm causes least-used addresses to fall out in favor of new

node addresses, and are suitable for use in large networks. They are self-learning, so that as

eliminates bad packets and enables peak performance to be achieved when there is heavy

The Magnum CS14 and CSN14 Series units have address table capacity of 2K

4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing The RJ-45 ports support auto-cross (MDI or MDIX) in the auto-negotiation

connecting the CS14’s to other unmanaged switches, legacy hubs, managed switches,

mode according to the IEEE 802.3u standard. No crossover cables are needed when

frequently-used addresses. To reset the address buffer, cycle power down-and-up.

Series switch automatically keeps up with node locations.

Switching, Address Learning

traffic on the network.

Page 67 of the GarrettCom CS14 user manual — Switches, a rack-mount tray is
Page 67 · click to enlarge
Page 67

The (F–H) manual switch has been provided for fiber port #1, for fixing that

auto-negotiation is changed in the managed switch by the manager commands. In such

advertises its capability for 10 or 100 Mbps speed and F/H duplex mode, and the device

100Mbps speed, and full- or half-duplex mode. 4.3 (F- H) Switch, Full-Duplex or Half-Duplex options for Fiber port# 1

media-converters etc. Please note that there can be conditions with managed switches

at the other end of the cable should similarly advertise / respond. Both sides will agree

to the speed and mode to be used per the IEEE 802.3u standard. Depending upon the

port at Full or Half Duplex as per the requirements. The (F-H) manual switch is being

cases, the 10/100 speed or the F/H mode may be affected, but auto-cross in the CS14

When an RJ-45 cable connection is made, and each time LINK is enabled,

where the switch manager fixes the port settings via software, and the result of the

auto-negotiation takes place (except for legacy products, which do not have auto-

negotiation and which go to the default state accordingly). The Magnum Switch

devices connected, this will result in agreement to operate at either 10 Mbps or

Switches will still work. The auto-cross function cannot be disabled.

Page 68 of the GarrettCom CS14 user manual — 4.4 Dual LEDs, Front-panel and side-panel (Magnum CS14 and CSN14) LED Description
Page 68 · click to enlarge
Page 68

LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will turn

off in the event connectivity is lost between the ends of the twisted pair segment

and the 100Mb being set at Full-Duplex as default from the factory. The port can be set at

represented by LA1, LA2, LA3. (Steady On or steady Off indicates no Receive

located underneath the fiber port. The Fiber port with 10Mb is being set at Half-Duplex,

or a loss of power occurs in the unit or remote device. The Link ports are also

4.4 Dual LEDs, Front-panel and side-panel (Magnum CS14 and CSN14) LED Description

10/100 Steady ON for 100Mb speed, OFF for 10Mb speed per port F/H Steady ON for Full duplex mode, OFF for half duplex per port

the required mode, by sliding the manual switch position to “F” or “H”.

PWR Illuminates GREEN to indicate power applied.

Activity).

Page 69 of the GarrettCom CS14 user manual — 5.0 TROUBLESHOOTING
Page 69 · click to enlarge
Page 69

Mb/s Switch is not performing as expected, do not attempt to repair the unit; instead contact

Should problems develop during installation or operation, this section is intended

to help locate, identify and correct these types of problems. Please follow the suggestions

consistently high performance in all network environments. The installation of Magnum

INSTALLATION, Section 3.0); the operation is also straightforward and is discussed in

procedures described in this section or if the Magnum CS14 and CSN14 Series 10/100

CS14 and CSN14 Series 10/100 Mb/s Switches is a straightforward procedure (see

listed below prior to contacting your supplier. However, if you are unsure of the

All Magnum Ethernet products are designed to provide reliability and

your supplier for assistance or contact GarrettCom Customer Support.

5.0 TROUBLESHOOTING

Section 4.

Page 70 of the GarrettCom CS14 user manual — Switches, a rack-mount tray is
Page 70 · click to enlarge
Page 70

CS14 and CSN14 Series unit. Be certain that the AC power cord is plugged

5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back

into a functioning electrical outlet. Use the PWR LEDs to verify each unit

to the Installation Section of the applicable chapter of this manual. Also

2. Check the cables and connectors to ensure that they have been properly

impaired during installation. (About 90% of network downtime can be

3. Make sure that an AC power cord is properly attached to each Magnum

connected and the cables/wires have not been crimped or in some way

check to make sure that the various components of the network are

attributed to wiring and connector problems.)

interoperable.

is

Page 71 of the GarrettCom CS14 user manual — Switches, a rack-mount tray is
Page 71 · click to enlarge
Page 71

CS14 and CSN14 Series 10/100 Mb/s switch product, it is recommended that

the problem device is replaced with a known good device. Verify whether or

5. If the problem continues after completing Step 4 above, contact your supplier

not the problem is corrected. If not, go to Step 5 below. If the problem is

corrected, the Magnum CS14 and CSN14 Series Switch and its associated

of the Magnum CS14 and CSN14 Series 10/100 Mb/s Switch unit or if

4. If the problem is isolated to a network device other than the Magnum

unknown, contact GarrettCom, Inc by fax, phone or email

(support@garrettcom.com) for assistance.

cables are functioning properly.

receiving power.

Page 72 of the GarrettCom CS14 user manual — 5.2 When Calling for Assistance
Page 72 · click to enlarge
Page 72
2. An accurate list of GarrettCom product model(s)involved, with serial number(s).

including Convenient computers, workstations, terminals and printers; plus, the

Include the date(s) that you purchased the products from your supplier.

d. Any particular application that, when used, appears to create the problem;

3. It is useful to include other network equipment models and related hardware,
4. A record of changes that have been made to your network configuration prior
1. A complete description of the problem, including the following points:

Please be prepared to provide the following information.

c. The components involved in the problem;

a. The nature and duration of the problem;

various network media types being used.

b. Situations when the problem occurs;

5.2 When Calling for Assistance

Page 73 of the GarrettCom CS14 user manual — Switches, a rack-mount tray is
Page 73 · click to enlarge
Page 73

5.3 Return Material Authorization (RMA) Procedure All returns for repair must be accompanied by a Return Material Authorization

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

to the occurrence of the problem. Any changes to system administration

Failure symptoms, including a full description of the problem.

(RMA) number. To obtain an RMA number, please use this URL -

Name and phone number of your contact person.

Packing List Number (or Sales Order Number)

Please have the following information readily available:

procedures should all be noted in this record.

Name of your company / institution

Serial Number (or Invoice Number)

Your shipping address · Date of installation · Product name

Page 74 of the GarrettCom CS14 user manual — Switches, a rack-mount tray is
Page 74 · click to enlarge
Page 74

GarrettCom will carefully test and evaluate all returned products, will repair products that

are under warranty at no charge, and will return the warranty-repaired units to the sender

details). However, if the problem or condition causing the return cannot be duplicated by

GarrettCom reserves the right to charge for the testing of non-defective units

under warranty. Testing and repair of product that is not under warranty will result in a

with shipping charges prepaid (see Warranty Information, Appendix A, for complete

No Problem Found.

GarrettCom, the unit will be returned as:

customer (user) charge.

Page 75 of the GarrettCom CS14 user manual — 47823 Westinghouse Drive Fremont, CA 94539
Page 75 · click to enlarge
Page 75
1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet

Should you need to ship the unit back to GarrettCom, please follow these instructions:

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

or bag for shipping protection. ( You may retain all connectors and this

3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to: GarrettCom, Inc.

This material may cause electro-static shock damage to the unit.

47823 Westinghouse Drive Fremont, CA 94539

5.4 Shipping and Packaging Information

Attn.: Customer Service

Installation Guide.)

Page 76 of the GarrettCom CS14 user manual — APPENDIX A: WARRANTY INFORMATION
Page 76 · click to enlarge
Page 76

During this warranty period, GarrettCom will repair or, at its option, replace components in

has been damaged by misuse, misapplication, or as a result of service or modification other

Please complete the warranty card as this acts as a product registration, and mail

This warranty will not be effective if, in the opinion of GarrettCom, the product

GarrettCom, Inc. warrants its products to be free from defects in materials and

workmanship for a period of three (3) years from the date of shipment by GarrettCom.

the products that prove to be defective at no charge other than shipping and handling,

than by GarrettCom. GarrettCom reserves the right to make a charge for handling and

inspecting any product returned for warranty repair which turns out not to be faulty.

provided that the product is returned pre-paid to GarrettCom.

APPENDIX A: WARRANTY INFORMATION

it to GarrettCom within two weeks of your purchase.

Ask about the GarrettCom CS14

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom CS14

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom CS14 manual PDF

76 pages·778 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…