Installation and User Guide


GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a
serviceable parts. Attempted service by unauthorized personnel shall render
all warranties null and void. If problems are experienced with Magnum
of this publication may be reproduced without prior written permission from
8000X Mixed-Media Fiber Hub products, consult Section 6,
Copyright 2002 GarrettCom, Inc. All rights reserved. No part
UL is a registered trademark of Underwriters Laboratories
NEBS is a trademark of Telcordia Technologies
Ethernet is a trademark of Xerox Corporation
Troubleshooting, of this User Guide.
registered trademark of GarrettCom, Inc.
Printed in the United States of America.
GarrettCom, Inc.
Trademarks

This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to take
Please use the mailing address, phone and fax numbers and email address listed
Radio Frequency Interference Statement
47823 Westinghouse Drive Fremont, CA 94539
whatever measures may be required to correct the interference.
GarrettCom, Inc.
below:
Federal Communications Commission · Fax (510) 438-9072 · Contacting GarrettCom, Inc

Magnum DS80 Dual-Speed Personal Hub Installation and User Guide (05/ 02)
GarrettCom, Inc.offers the premium-quality Magnum line of Ethernet LAN
connectivity products with industry-standard functionality and built-in fiber
configurability. Magnum products are designed for use in demanding Carrier Class,
Industrial Grade and OEM applications where reliability is a primary consideration.
6K25 Managed Fiber Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports, mix-and match. Features SFF fiber for up to 25 fiber ports in a 1U unit.
4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto-negotiating full switching performance.
Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed
Transceivers, 10Mb series Mini-Transceivers and Coax Models Apr, 02
“Outdoor” Ethernet Switch, for temperature uncontrolled locations
Mixed-Media Fiber Hub, 16-port Stackable,10/100 auto-sensing
Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing
6 10/100 and 2 100Mb fiber ports, can be connected in strings
10Mb series and 100Mb series, both w/ optional port modules Personal Switches, 10/100Mb
8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series
All media combinations, incl. fiber ST, SC, mm., single mode
Bridge Port Modules (BPMs), 4 types, for segment isolation
Repeater Port Modules (RPMs), 6 types for Ethernet media
The “X-line” of configurable MiXed Media products:
Stackable Concentrators, SNMP optional, 13-Ports
and mixed-media types, full switching performance.
8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb
Mini-Concentrators, 7 Ports, Repeaters, 2-Ports
8-port, with two switched ports (1 fiber built in)
Stackable Hubs, SNMP Optional
Personal Hubs, 10Mb series



distances and PDV; Port Module (PM) Installation; Installing PM Cards in the
Calculations for Fiber Media; Optional 48VDC power supply; Optional 48V Dual-
Magnum 8000X; Preparation for Installing and Removing SPMs; Installing
Source DC power; Optional Dual Power Supply, AC Power; Optional Dual Power
Communications). There are no changes to the content of the material at this time
SPM module in Magnum 8000X; Removing SPM module; Power Budget
125VDC Power Supply option
Supply, 48VDC Power.
Fiber Hub user manual.
Revisions

Performance (hub supports both 10 and 100Mb domains, ports individually selected)
100Mbps : Ethernet IEEE 802.3u , 100BASE-TX, 100BASE-FX, 100BASE-SX 10 Mbps : Ethernet IEEE 802.3, 10BASE-T, 10BASE-FL RJ-45 ports are auto-sensing for speed: IEEE 802.3u
Filtering and Forwarding Rate from 100Mbps ports : 148,800 pps max
Filtering and Forwarding Rate from 10 Mbps ports : 14,880 pps max.
Packet-Processing Between Domains (internal 10/100 switch or bridge)
Ambient Temperature: 32ºF to 122ºF (0ºC to 70ºC) Storage Temperature: -20ºC to 70ºC
Latency (not including packet time) : 100 to 10 Mbps : 5µs 10 to 100Mbps : 5µs CPU Type : State Machine
10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)
100BASE-FX, full duplex:(single-mode) - 15.0 km (49,215 ft)
10BASE-FL single-mode fiber optic - 10 km (32,810 ft)
100BASE-SX, short wavelength hdx (m.m.) - 300 m ( 935 ft) 100BASE-FX, full duplex:(multi-mode) - 2.0 km (6,562 ft)
100BASE-FX, half-duplex:(multi-mode) - 412 m (1350 ft)
100BASE-FX, half-duplex:(single-mode) - 412 m (1350 ft)
10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)
100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
Shielded twisted pair - 150 m (492 ft)
Maximum Ethernet Segment (or Domain) Lengths
When a port is operating at 100Mbps
When a port is operating at 10 Mbps :
1.0 Technical Specifications
Power Supply, AC (Internal)
Operating Environment · Network Standards

For Dual Source and Redundant DC for –48VDC, 24VDC Power & 125VDC
100Mbps copper (RJ-45): Category 5 UTP/STP 10 Mbps copper: Cat 3, 4, 5 UTP (Note: auto-neg. doesn’t sense cable type)
Stacking Cable - stacking may be up to three units (48 ports) of mixed-media
8000X hubs and/or DS8016-A Dual-Speed hubs. A stacking cable with 25 pin DB25 male connectors, shielded, 9 inches (23
Enclosure: High strength metal. 1U rack-mounting brackets included.
Dimensions: 1.75 in H x 17 in W x 9 in D ( 4.4cm x 43.2cm x 22.9cm)
Three years, return to factory Made in USA
For optional 23” Telco rack-mount brackets, order Model # RMB-23W
cm) long, is included with each Magnum 8000X-A add-on unit.
Suitable for wiring closet shelf, 19” rack or desktop mounting.
Multi-mode (62.5/125 typical) and single-mode (9/125 typical)
Network Cable Types (Modular on a per-port basis)
supply options (Optional), see Appendices
Fiber ports at 100Mbps and/or at 10 Mbps:
fixed 100Mbps speed operation)
Safety :UL Listed (UL 1950), cUL, CE
DC Power Supply (Options)

Two LED indicators per fiber port, in each PM, are “L” for LINK is made, “A” for traffic Activity.
ready (or nothing is connected), steady ON indicates 100Mbps operation and OFF means 10 Mbps
PM-RJ45 -T, TX 10/100 auto-neg. RJ-45 twisted pair
Additional LED for RJ-45 ports are “S” for Speed, where flashing indicates auto-negotiation is
FPM-MST FX 100Mbps ST “twist-lock” multi-
FPM-MSC FX 100Mbps SC “snap-in” multi-
FPM-SSC FX 100Mbps SC “snap-in” single-
FPM-MTRJ FX 100Mbps MT-RJ “plug-in” multi-
FPM-MV45 FX 100Mbps VF-45 “plug-in” multi-
FPM-SXMST SX 100Mbps ST “twist-lock” multi-
FPM-SXMSC SX 100Mbps SC “snap-in” multi-
FPM10-MST FL 10Mbps ST “twist-lock” multi-
FPM10-MSC FL 10Mbps SC “snap-in” multi-
FPM10-SST FL 10Mbps ST “twist-lock” single-
FPM10-SSC FL 10Mbps SC “snap-in” single-
PM Model # IEEE Standard Speed Connector type -Mode
FPM-MFC FL 10Mbps FC “screw-on” multi-
PM-RJ45U -T, TX 10/100 auto-neg. RJ-45 with up-link sw. TP
1.1 Specifications - Port Modules, for front ports of the Magnum 8000X (For Power Budget data, see Section 4.5)
SPM Type * SPM-TTX SPM-FDSC SPM-FDST SPM-FDSSC
& 10BASE-T 100BASE-FX mm* f. duplex 100BASE-FX mm* f. duplex 100BASE-FX sgl.mode, fdx
* PDV (path delay value) of an SPM is the same as a user-node i.e. , 50 BT
Connector Type RJ-45 Fiber-SC Fiber-ST Fiber-SC
1.2 Specifications - Switching Port Modules (SPMs) for bonus port
LINK LED yes
Receive (RX) LED yes
Up-link switch yes n.a. n.a n.a.
10/100Mb switch yes n.a. n.a. n.a.
PM-BLNK Blank cover for an unused port slot
(For power budget data, see Section 4.5)
operation has been selected by the last auto-negotiation session.
Physical Signaling Type 100BASE-TX

operation per port. Any mix of 100Mbps and 10 Mbps Fiber PMs (see list below) may be
connection. May be stacked with up to two DS8016-A or -E or 8000X-A add-on units for up
Magnum 8000X-A Add-on Chassis, 16 PM slots, no switch inside, use for stacking
** To convey configuration information to the factory, order chassis units followed by the
FPM-SXMST Module w/100Mbps mm* Fiber SX ST connector (when available)
FPM-SXMSC Module w/100Mbps mm* Fiber SX SC connector (when available)
PM-RJ45 Module w/ RJ-45 for TP copper, supports 10/100 auto-negotiation
SPM-FDSSC SPM w/ full-duplex single-mode fiber FX SC connector, includes
PMs to be configured in it. For example, to order a Model 8000X Hub with a ten FPM10-
MST ports factory installed, call out “Qty 1 Model 8000X" and then in sequence “Qty 10
Model FPM10-MST” as separate line items. This signifies that the ten FPM-MST modules
GarrettCom, Inc. reserves the right to change specifications, performance characteristics
1.3 Ordering Information (see Appendices for DC power supply options)
PM-RJ45U Same as PM-RJ45 except includes an up-link (crossover) switch
SPM-FDSC SPM w/ full-duplex multi-mode fiber FX SC connector, includes
a separate switch with packet buffers and filter/forward operation
a separate switch with packet buffers and filter/forward operation
factory or field configured. Includes a switch inside that bridges the two internal traffic
Magnum 8000X Base Chassis with 16 Port Module (PM) slots for 10/100
domains. Has a bonus port for an optional switched fiber or copper (SPM) backbone
FPM-MFC Module w/10Mbps mm* Fiber FX FC “screw-on” connector
SPM-TTX SPM with RJ-45, manually selected as 10Mb or 100Mb speed
configuration, order “Qty 10 Model FPM10-MST (do not configure)”, for example.
to 3 units (48 front ports for users) in a stack. Internal universal power supply.
are to be factory-configured in the 8000X unit. To order loose modules for field
FPM-MTRJ Module w/100Mbps mm* Fiber FX MT-RJ connector
FPM-MV45 Module w/100Mbps mm* Fiber FX VF-45 connector
FPM-SSC Module w/100Mbps sgl.m* Fiber FX SC connector
FPM-MST Module w/ 100Mbps mm* Fiber FX ST connector
FPM-MSC Module w/100Mbps mm* Fiber FX SC connector
FPM10-MSC Module w/10Mbps mm* Fiber FL SC connector
F PM10-SST Module w/10Mbps sgl.m* Fiber FL ST connector
FPM10-SSC Module w/10Mbps sgl.m* Fiber FL SC connector
FPM10-MST Module w/10Mbps mm* Fiber FL ST connector
SPM-FDST Same as -FDSC, but with ST connector
Switch Port Modules (SPMs) for the Bonus Port:
PM-BLNK Blank cover for an unused port.
Magnum 8000X Mixed-Media Fiber Hubs **
* mm = multi-mode, sgl.m = single-mode
8000X Front Port Modules (PMs):
and/or model offerings without notice.

or delivery. Inspect the contents of this package for any signs of damage and ensure that
product; notify the carrier of any damage which you believe occurred during shipment
unit needs to be returned please use the original shipping container. Refer to Chapter 5,
Examine the shipping container for obvious damage prior to installing this
Remove the unit from the shipping container. Be sure to keep the shipping
In the event there are items missing or damaged contact the supplier. If the
container should the unit need to be shipped at a later date. To validate the product
warranty, please complete and return the enclosed Product Registration Card to
Port Modules purchased for field installation will be boxed in a “bar-of-
configured and installed, and may be included as part of the 8000X unit
2.0 Introduction - Magnum 8000X Mixed-Media Fiber Hub
soap-size” cardboard carton with labeling to indicate the contents.
Troubleshooting, for specific product return procedures.
2.1 Inspecting the Package and Product
GarrettCom, Inc. as soon as possible.
the items listed below are included.
This package should contain:
when it is received.

The Magnum 8000X brings you the future of Fiber Optic connectivity. The
100BASE-SX. The Magnum Dual -Speed 8000X supports almost all the popular fiber
The Magnum 8000X is designed with the capability to be stacked with other
high performance, the Magnum 8000X accepts a variety of fiber modules so that users
can choose the fiber port types desired. A dozen different 100Mbps and 10 Mbps fiber
supported with DS8016-A Hubs configurable in the stacks, rack-mounting is standard,
optional 48V DC power supplies (even dual-source DC or redundant DC) are available
Media Fiber hubs that provides the flexibility of configurable fiber and RJ-45 ports, of
sensing for 10/100 speed, adapting to match the speed of the connecting device. These
Mbps Ethernet to 100Mbps Fast Ethernet. Sixteen port slots are located on the front of
interconnecting the two domains. The automatic per-port speed-sensing is continuous,
Designed for “fiber-to-the-desktop” applications that are economical and
Modules for switched backbone connections, stacking up to 3 units high (48 ports) is
for telecom equipment applications, and RJ-45 ports when used are auto-sensing for
Magnum 8000X based on new technology is a highly versatile, cost effective Mixed-
10 Mbps or 100Mbps Ethernet speed per hub. Each RJ-45 port is independently auto-
port connector i.e. ST, SC, FC, MT-RJ, and VF-45 in multi-mode or single-mode as
applicable, and can be installed as 100Mbps or 10 Mbps speed (10Mb port connector
types are ST, SC and FC only). The Magnum 8000X hubs support two shared traffic
desktop” and “fiber-for-security” networks that are gradually transitioning from 10
Magnum 8000X-A’s and/or with Magnum 8016-A’s. Magnum 8000X units may be
capabilities provide the ultimate in flexibility for small to medium sized “fiber to
Combinations of standard Ethernet media types are supported. These
Rich with configuration options, the 8000X units support either 10 or
100Mbps fiber modules per port, a rear bonus port accepts optional Switch Port
include 10BASE-FX, 10BASE-T, 100BASE-FX, 100BASE-TX, and (proposed)
domains, one at 100Mbps and one at 10 Mbps, with an internal bridge or switch
allowing a connected device to change speed and re-LINK at any time without
port module types are supported, and they are factory or field configurable.
impairing the operation of the other ports and connected devices.
the unit, are accommodated in a 1U rack-mount package.
2.2 General Information
2.3 Product Description
speed.

automatically expand to support all of the ports in the stack. Any combination of 10 and
time. In a stacked configuration, the complete stack operates as one logical dual-speed
The Magnum 8000X is compact in design at only 1.75 in. (4.4 cm) high, and
has a lightweight metal enclosure. It is easily rack mounted in a standard 19" rack and
cabling. The 8000X is configured by selecting individual PMs, one per Ethernet port to
network activity of all segments installed in the unit.Figure 2.3.b: Front Panel LEDs
LEDs to indicate operating status are on the left front side. There are power
the auto-ranging internal power supply that automatically adapts to the AC voltage of
configured in a stack with as many as 3 total units. The two shared traffic domains
100Mbps ports, up to the maximum 48 ports (3units) in one stack, can be use at any
Magnum 8016s units), up to 48 front Ethernet segments with any mix of fiber and
bridge module (daughter board). There are 16 front slots for mixed-media modules.
which will provide either 10 or 100Mbps operation over either fiber or twisted pair
be used. Configured 8000X units provide two traffic domains, one each with IEEE

The Magnum 8000X chassis houses one main PC board and an internal
Each front slot in the dual-speed chassis can accept any 8000X Port Module (PM)
repeater. Depending upon the stack configuration (any mix of Magnum 8000Xs,
typically operates as the central hub for a multiple-backbone Ethernet network.
(PWR) and bridge-inside (BR) indicators for the unit. There are collision (COL)
R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
COL
2.3.1 The Magnum 8000X Fiber Hub Chassis
802.3 and 802.3u repeater functionality.
100Mbps domains for visual indication
LEDs provide a visual assessment of the
indicators for each of the 10 Mbps and
of the operating status of each domain,
traffic activity on each domain. These
and two activity (ACT) indicators for
operational condition and aggregate
copper ports is supported.
Mixed-Media Hub · Magnum 8000X

the AC power system into which it is being installed. An ON/OFF power switch is used
needs to be reset. AC Power input is auto-ranging, from 100 to 240vac with a frequency
or all of which may be configured at a given time. The bonus slot allows for an optional
for powering the hub on and off when it is placed in or taken out of service, or when it
to 63 Hz. When shipped for use in U.S. and Canada, a 115vac power cord is included.
types. An SPM will segment the 8000X from the other parts of the network connected
(PMs) are used with the Magnum 8000X. The Magnum 8000X features 16 PM slots on
the front of the unit and a bonus port slot on the rear of the unit, some (minimum of 2)
rear-mounted switched Ethernet segment connection, typically to a backbone.With the
OFF
mounted and is optionally configured with any one of the Switch Port Module (SPM)
stacked with up to two Magnum 8000X-A and/or Magnum DS8016-A units to form
one logical dual-speed repeater. Instructions for the using the IRB connectors on the
Magnum 8000X are discussed in detail in Section 2.6, "Stacking Magnum 8000Xs".
bonus slot, the 8000X becomes a 16-port dual-speed hub with one switched up-link.
There are a total of six standard PM cards, each for a specific media cable
maximize reliability, even in wiring closets with ambient temperatures up to 50°C.
connector. A seventh module type is used as a face plate when any front slot is not
desirable for 100Mb traffic domains which are Path Delay Value (PDV) limited.
To provide maximum application flexibility, individual Port Modules
fan. The fan will maintain low temperature operation inside the unit to
to it, providing flexibility in the network topology. This flexibility is especially
PMs for the front slots may not be used in the rear Bonus Port slot.
Bonus Port Slot, configurable via
(SPM - FST shown)
2.4 Port Modules (PMs)
P3 - Interface to unit above.
P4 - Interface to unit below.
IN

with an up-link switch, “FPM-MTRJ” for fiber MT-RJ (small form factor 100BASE-FX
“PM-FP” for the face plate to cover blank slots. PM-RJ-45 (not shown) looks like PM-
PMs for other fiber port types (for example, 10 Mbps FC-type) are possible as
filters and forwards packets, thus separating internal and external collision domains and
used. The Magnum 8000X PM network connector types, shown left-to-right in Figure
2.3a below, are “PM-RJ45U” for RJ-45s (10BASE-T or 100BASE-TX, UTP and STP)
multi-mode), “FPM-MSC” for 100Mb fiber SC (100BASE-FX multi-mode) and same-
MST” for 100Mb FX fiber ST m.m., “FPM-MV45” for fiber VF-45 (small form factor
100BASE-FX multi-mode), the “FPM-SXMST” for 100BASE-SX (short-wavelength
factory prior to shipment, but may be installed or changed or removed in the field by a
Magnum Switch Port Modules (SPMs) provide a compact switching port that
enhancing the performance and configurability of the network. Unless specified at the
SPM installed. For application flexibility, any of the Magnum SPMs may be specified
in-appearance “FPM-SSC” for 100Mb fiber SC (100BASE-FX single-mode), “FPM-
multi-mode ST), designed to be compatible with 10 Mbps FL, when available), and
RJ45U but without the up-link switch. For additional details and descriptions of each
Magnum PMs are normally installed in the front of Magnum 8000Xs at the
time of order, each Magnum 8000X is shipped from the factory with no bonus port
careful technician. The PM removal / addition procedures are described in Section
specials. If you need a different port type from those shown, contact GCI

A L S A L A L A L A L A L
Port Module, see Section 5 of this manual.
2.5 Switch Port Modules (SPMs)
5.2.1.- 5.2.7.


for factory configuration at time of order. It is also possible for the rear bonus port to be
forward the packet to the other port. Error packets are always filtered. For good packets,
the filter or forward decision is made based on the destination address contained in each
didn’t find a match in the address table, then is it forwarded to the other segment. If it is
For the specifications of available Switch Port Modules (SPMs), see Section
The SPM has two ports - one where media attaches, and one connecting into
the inside of the mixed-media fiber hub in which the SPM is mounted. For each packet
a new address which the SPM didn’t previously didn’t know about, it “learns” the new
address and puts it in the port’s address table. The address tables have a capacity of 1K
re-configured in the field by a trained technician to add or exchange a Switching Port
Module. Figure 2.5a below shows the internals of the Magnum 8000X with an SPM
received by either port of the SPM, a decision is made to either filter the packet or to
packet. If the destination address is on the segment from which the packet originated,
then it is filtered and not forwarded to the other segment. If the destination address
MAIN BOARD
installed in the Bonus Port, accessible from the rear.
1.3. The functions of an SPM are described below.
addresses for each port.

NOT in its address table. Segment 2’s packets are forwarded
when the destination addresses are
when the destination addresses are
Packet Source Destination Address Table Filter/Forward
medium-sized to large networks. The address tables are flushed periodically to update
the network status and to purge any inactive stations from the tables. See the figure and
Segment 2’s packets are filtered
available bandwidth for the users on both the hub side and the rear-segment side of the
and using up bandwidth needlessly. This results in more available network bandwidth
on both sides and a throughput increase for all users on both segments. An SPM needs
By selectively forwarding packets from the mixed-media hub’s ports (or hub stack’s
preventing unnecessary packets and bad packets from traveling to the other segment
ports) to the rear-connector port based on its switching logic, an SPM increases the
network. As shown in Figure 2.5b, it keeps the local traffic on each side contained,
With this large address table, SPM port modules can serve the needs of
NOT in its address table.
Source Address Address Maintenance Action
Seg. 1 Not in table Not in table Add source to table Forward
Seg. 1 In table Not in table None Forward
Seg. 2 Not in table Not in table Add source to table Forward
Seg. 2 In table Not in table None Forward
in its address table.
Seg. 1 Not in table In table Add source to table Filter
Seg. 1 In table In table None Filter
Seg. 2 Not in table In table Add source to table Filter
Seg. 2 In table In table None Filter
(Bonus Port) (Inside of Hub)
Segment 1 Segment 2
Segment 1’s packets are forwarded
when the destination addresses are
when the destination addresses are
Segment 1’s packets are filtered
table that follows:
in its address table.
SPM Module


no software configuring and is transparent to system and application software, including

buffer for temporary storage, particularly when operating at different speeds (such as 10
and 100) or with different traffic types (shared and full-duplex). The SPM-FDST packet
Ethernet cable distances of up to 2km, much more than the 412m half-duplex distance
As shown in the figure, the jumper located on the SPM board by default is factory set
SPM-FDST temporarily stores unfiltered packets. It is desirable to have a large packet
These SPMs can also be configured to operate as a half-duplex switch port.
As is typical for bridges and switches, the internal packet buffer space of the
Therefore, the SPM-FDST extends the distance limits of Fast
Ethernet. In particular, with multi-mode fiber, it permits Fast
bonus port operates in full-duplex mode, sending packets on
domain” with full- duplex, and while this violates the specs
one fiber filament while simultaneously and independently
The significant feature of the SPM-FDST is that the fiber
of traditional Ethernet, it is accepted in most situations.
receiving packets on the other. There is no “collision
either half- or full-duplex mode, the
recommended that the device on the
other end of the segment be another
to full-duplex mode (position 2-3).
By setting the jumper in position 1-
device on the other end of the fiber
2.5.1 Magnum SPM-FDST
corresponding device. Since full-
duplex Fast Ethernet (802.3x) is a
network management software.
2, it will operate as shared (half
duplex). To operate properly in
full-duplex fiber SPM or equal.
limit otherwise obtainable.
recent 1997 standard, it is
segment must also be a
Magnum SPM-FDST · Magnum SPM-FDST

buffer is 1Mbps to maintain high network performance. The MAC address memory is
In summary, the Magnum SPM-FDST is a multi-mode fiber optic switching
port module. It has 100Mb ST-type connectors. There are two LEDs, LINK and RX,
to allow monitoring of LINK and packet reception (Activity) status of the SPM. The
fiber cabling and using the 100BASE-FX protocol. It filters and forwards packets in
SPM may be used to connect to another full-duplex 100Mbps hub or switch using
The Magnum SPM-FDSSC is a single-mode, full-duplex fiber optic switching port
module with a 100Mb SC-type connector. The module may be used to connect to
RX LINK
FX
SHARED
FX
SHARED
LINK and RX - to allow monitoring of link and
activity status of the SPM. The Magnum SPM-
another 100Mbps hub or switch using fiber cabling and
using the 100BASE-FX protocol. It filters and forwards
100Mb SC-type connector. The module may be used
fiber cabling and the 100BASE-FX protocol. It filters
The operation and application of the SPM-
packets in both directions at Fast Ethernet wire speed.
Since the SPM module segments the network, it also
switching functionality and has two LED’s -
to connect to another 100Mbps hub or switch using
above, except for the connectors on the fiber cable.
FDSSC is a full duplex module. Thus, two
The Magnum SPM-FDSSC includes full
The Magnum SPM-FDSC is a multi-mode, full-
duplex fiber optic switching port module with a
and forwards packets in both directions at Fast
FDSC is the same as the SPM-FDST described
maintains its address tables to know what node
8KB, suitable for medium to large networks.
both directions at Fast Ethernet wire speed.
addresses are on which side of the unit.
2.5.3 Magnum SPM-FDSSC
2.5.2 Magnum SPM-FDSC
Ethernet wire speed.
Magnum SPM-FDSSC

SPM-TTX RJ-45 10BASE-T & 100 -TX 10 or 100 shared 256KB 1024/port
Connector Standard Mb/s Traffic Pkt Buffer Address
SPM-FDST Fiber-ST 100BASE-FX 100/200 full-duplex 1MB 8K total
SPM-FDST Fiber-SC 100BASE-FX 100/200 full-duplex 1MB 8K total
SPM-SSC Fiber-SC 100BASE-FX 100/200 full-duplex 1MB 8K total
maximum distance of 15km of single-mode fiber optic cable in a Fast Ethernet
network. For an SPM-FDSSC used to connect into a separate collision domain,
SPM-FDSSC’s can be used together on each end of a fiber segment to get the
taking into account all the devices’ Path Delay Values (PDVs) that are part of
An SPM operating at 100Mbps has a PDV of 50 BT, i.e., the same PDV as a
The Magnum SPM-TTX is a 10 Mbps or 100Mbps device equipped with
RX - to allow monitoring of link and packet reception status of the SPM’s operation.
the cable distances and hop-counts allowable would have to be calculated
one RJ-45 port which supports either 10BASE-T and 100BASE-TX. The
RX
(See also “Specifications - SPMs,” Section 1.3)
10/100 speed selection is done with a manual switch on
the unit to prevent ambiguity where it may be used with
10BASE-T or a 100BASE-TX switch port. See Sections 2.5 and
The SPM-TTX filters and forwards packets, maintains
includes an up-link switch to allow for connection to either user
The Magnum SPM-TTX has two LED’s - LINK and
DTE or NIC card in a Fast Ethernet collision domain.
nodes or for cascaded up-link connections to other hubs. The
its address tables, and segments the network when used as a
other devices such as NICs that are auto-sensing.
2.5.1 for a general description of an SPM. The SPM-TTX
attached devices may be either 10 Mb or 100Mbps.
2.5.5 SPM Specification Summary Table
2.5.4 Magnum SPM-TTX
that domain.
Magnum SPM-TTX · Mb/s UPLINK

auto-negotiation standard. If the connected device or node indicates that it is capable of
technique is only for 10 / 100 speed, and does not provide for any full-duplex operation.
indicated by the ‘S’ LED for that port. The ‘S’ LED is steady ON when 100Mbps speed
Repeater Bus (IRB) connector on the left side. The IRB interconnects stacked units with
The 8000X Mixed-Media Fiber Hub can be stacked with Magnum DS8016-A
operation on that 8000X port will be at 10Mbps. Of course, the hubs’ auto-negotiation
When a twisted-pair port is connected and LINK is present, the speed on that
connected, the ‘S’ LED on that port will be blinking to indicate that it is trying to auto-
a stacking cable, enabling all stacked Magnum 8000X units to operate as a single dual-
daisy chain the IRB to the stacked unit above (unused on top unit in a Magnum 8000X
The IRB stacking shielded cables supplied with each Magnum 8000X-A unit
sensing for speed, independent of the other ports. Speed-sensing is performed by the
connector which is used to daisy chain the IRB to the stacked unit below (unused on
impaired by longer IRB RS232 cables. Stacks with total IRB lengths of as much as 9-
lengths, longer cables or unshielded cables are not permitted as they will not operate
Magnum 8000X’s electronics in accordance with the standards of the IEEE 802.3u
The rear of the Magnum 8000X Mixed-Media Fiber Hubs have an Inter-
speed repeater. There are two 25-pin IRB connectors on each unit: the bottom IRB
bottom unit in a Magnum 8000X stack); and the top IRB connector which is used to
Twisted pair copper ports (PM-RJ45 or PM-RJ45U only) support auto-
100Mbps speed, then operation on that port will be at 100Mbps. If the connected
port that has been sensed by the Magnum 8000X Mixed-Media Fiber Hub will be
are slightly longer than the base unit height. The operation of the stack will not be
inch long shielded cables can be implemented. However, non-standard IRB cable
device does not positively indicate that it is capable of 100Mbps speed, then the
is sensed, and is steady OFF when 10Mbps speed is in use. When the port is not
models, too. (But not with DS8016-B because of the “bridge-inside” conflict)
2.6 10 /100 Speed Auto-sensing (8000X front copper ports only)
2.7 Stacking Magnum Mixed-Media 8000X Fiber Hubs
stack). The IRB connectors for non-stacked units are unused.
negotiate. (See section 4.3 for the LED’s).
properly at 100Mbps speeds.

necessary packets to cross between the domains. This enables all of the users and nodes
other, and it keeps local traffic on one domain from consuming any of the bandwidth of
With one base model Magnum 8000X, up to two additional 8000X-A “add-
space along the left-side area for the exhaust of the internal cooling fan in each 8000X
Magnum 8000X’s contain a factory-installed bridge module to interconnect
connected into either domain, whether 100Mbps or 10 Mbps , to communicate to each
Normally, one Magnum 8000X hub is needed to provide a switch between the 10 and
on” units or two DS8016-A hub units can be stacked to operate as one 10/100 Dual-
Speed repeater with up to 48 dual-speed ports, with any mix of fiber and copper port
Fig.2.7a A stack of one Magnum 8000X and two DS-8016-A’s
When connecting mixed-media 8000X’s in a stack, use the stacking RS232
Figure 2.7b Magnum 8000X’s stacked. Cables connect “Out” and “In”

cable to connect the “OUT” stacking port from one 8000X unit to the “IN” stacking
port of the other. Push in the cable connectors until they seat in firmly. Also, leave
the two traffic domains, filtering and selectively forwarding packets to allow only
2.8 Bridge Module between the 10 Mbps and 100Mbps Domains
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 X
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 X

R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
100 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
100 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
100Mbps domains.
the other domain.
types.
unit.

packets and maintains optimum performance in both domains. Packet forwarding delay
maintained correctly even when users move their connection, or change speed, or power
The Magnum 8000X’s bridge module is implemented as a daughter board. 8000X units
compatible hubs, only one unit with a bridge inside may be operating in any one stack.
products, enabling the 8000Xs to maintain high network performance. The bridge has
internally. (The Model 8000X-A is an “add-on” unit for stacking, and has no bridge
The bridge operates in the store-and-forward mode, which filters out bad
is only 5µs (plus packet time), much less than traditional store-and-forward bridge
have an LED on the front labeled BR that will be ON when the module is installed
inside, so it’s BR LED will be off). In a stack of Magnum 8000X’s and / or other
8K node address capacity, suitable for use in large networks. Addresses are self-
learning so that filtering / forwarding of 10 Mbps and of 100Mbps packets is
down.
Bridge Module

! Mixed-Media 10 & 100Mb fiber port types in one unit for maximum flexibility
The Magnum 8000X is configurable with up to 16 economical port modules, and any or
all of the ports may be either 10 or 100Mbps fiber. RJ-45 ports may also be configured,
An internal universal power supply allows any Magnum 8000X unit to be used with the
Magnum 8000X Dual-Speed Fiber Hubs combine two logical hubs --- one at 10 Mbps
and one at 100Mbps --- in one physical box supporting two traffic domains. Each port
supported, making the 8000X Fiber Hub ideal for “fiber-to-the-desktop” applications.
The Magnum 8000X chassis and each of the 16 front-mounted PM cards are equipped
with traffic activity and segment-status LEDs, conveniently monitored from the front.
The Magnum 8000X operates as a hardware switch between domains, only forwarding
those packets from each domain that are needed on the other domain. Internal address
normal AC power types found around the world. (A 48VDC power supply is optional)
duplex fiber operating at 100Mbps, an optional SPM may be installed. This provides
The Magnum 8000X is equipped with an inter-repeater bus that allows multiple units
All RJ-45 ports support 10/100 auto-negotiation for speed, IEEE802.3u. compliant.
tables are self-learning, enabling users to change port connections or 10 or 100Mbps
! Switched port in the rear Bonus Port for a FDX fiber backbone, optional
To segment a Magnum 8000X (or stack) from a connected hub or switch using full-
supports up to 48 ports with all ports operating as a single dual-speed mixed-media
distances up to 2Km for the fiber link, and improved performance for the 8000X’s
with per-port selection. Port Modules with all kinds of fiber connector types are
(one 8000X and up to two 8000X-A units or two DS8016-A) to be stacked, thus
! Supports 10 or 100Mb network connections on each of sixteen ports
! Installation is “Plug and Play”, Operation is Transparent to Software
! Auto-sensing for speed, 10 or 100Mbps, on each RJ-45 front port
! Internal Power Supply, Auto-ranging AC voltage and frequency
can operate at either 10 or 100Mbps, independently of the other ports.
! Stackable and Scaleable Configurations
! LEDs for Chassis and PM Cards
domains without affecting operations.
2.9 Features and Benefits
repeater.
users.

See also Section 1.0, Technical Specifications, for additional Magnum 8000X
A Magnum 8000X Dual-Speed Fiber Hub handles all of the users at 10 Mbps
and 100Mbps over fiber and copper in the same hub unit. Port modules can be changed
stacking feature) provides for easy expansion of the network, and it provides flexibility
to adapt to new fiber port connector types as technology changes. The flexibility of the
cabling installed in the building from the wiring closet to each PC. They have operated
Internet access. Now they require higher bandwidth to accelerate their network. They
want to upgrade three of their present users to 100Mbps speed and expand for another
accessible by all users. The file server and the Internet access, devices located adjacent
secure network is the first priority, the possibility of eavesdropping (as is possible with
The 8000X Port Modules are factory and field configurable. This (and the
copper wiring) must be prevented. Fiber LANs are regularly used to connect to each
or added over time to suit expansion and additional changes. The 8000X is initially
configured with eight ports at 100Mbps fiber, two ports at 10Mbps fiber, and three
10/100 RJ-45 copper ports. The Magnum 8000X not only increases the network’s bandwidth and efficiency, but it also handles existing 10Mbps nodes over fiber in a
economical way. The print server stays at 10Mbps over twisted pair wiring, and is
the network setup at 10 Mbps. They have five users, a 10Mbps print server, and
five 100Mbps users (all with fiber), and they expect a few more users next year.
Magnum 8000X makes it the choice for applications that require a flexible and
8 100Mb fiber segments
8 100Mb fiber, 2 10Mb fiber, 3 10/100 RJ-45

Magnum 8000X configured here with
to the 8000X, operate over twisted pair at 100Mbps.
A diagram of the installation is shown here.
information that may indicate suitable applications.
2.10 Applications
desktop and each node.
adaptable 10/100 hub.

Fiber segments, 100Mb or 10Mb
isolation. In this kind of environment where computer systems are used to monitor and /
agents in the equipment. The SNMP management fiber network almost always operates
quantity or mix of standard port connector types. Individual 10/100 RJ-45 ports may be
The Magnum 8000X Fiber Hubs support all of the fiber port types (including the latest
provides for growth in performance to higher bandwidth 100Mbps speed, and the per-
or manage operations, an Ethernet fiber link is used to collect real-time data via SNMP
The Magnum 8000X Dual-Speed Fiber Hub is ideal in these situations. The
network. Stacking provides capacity for up to 48 ports, and the 8000X can be stacked
models), adapting the fiber LAN to changing technology. The Dual- Speed feature
(such as steel mills, electrical generating stations, telecom central offices, hospitals,
at 10 Mbps. Network management workstations and network servers use 100Mbps
etc.), fiber LAN cables are usually used for noise immunity and electrical ground-
fiber ports are economical and may be a mix of 10 and 100Mbps, and may be any
configured also, and an optional SPM can segment local users from the rest of the
with a DS8016-A for a mix of RJ-45 and fiber ports. The flexibility results in a
“future-proof” fiber hub. The illustration below shows this type of installation.

is stackable up to 3 units, and economically
supports all fiber types to the desktop for
Magnum 8000X has 16 ports per unit,

maximum security and flexibility.
port modularity plus stacking provide for port expansion.
and stackability for the ultimate in “future-proofing”,
modules (both 10Mb and 100Mb), 10/100 RJ-45,
Magnum 8000X offers a full range of fiber port
ports to the high performance nodes.
even noisy specialty environments
1 R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
1 R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
1 R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
Print Server

The location of the Magnum 8000X is dependent on the physical layout of the
accommodated on a shelf or table top, it is recommended that larger stacks be
1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment
2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate air flow must be maintained for proper and
3.) If the equipment is mounted in an enclosed or multiple rack system placement of the equipment must not overload or load
4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent
5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and
wiring closet but because it has rubber feet it can also be installed on a shelf
rack mounted. Each unit is shipped with a pair of metal "ears" that attach to
network and the area to be served. The unit is typically rack mounted in a
or table top. While stacks of up to 3 units and the associated cabling can be
unit. This is accomplished by using a family of Port Modules (PMs) which
can be individually selected and configured per-port. See Section 2.4 for a
Before installing the equipment, it is necessary to take the
designed to support all standard Ethernet media types within a single hub
RETMA racks. (Brackets for 23” telco racks are optional at extra cost).
The Magnum 8000X Mixed-Media Fiber Hub is specifically
each side of the unit to easily accommodate mounting in standard 19"
Hub, as well as connection of the various Ethernet media types.
overloading of the building/s electrical circuits.
must be less than or equal to 500C.
uncompromised earthing path.
3.1 Locating the Magnum 8000X
3.0 Magnum 8000X Installation
3.2 Connecting Ethernet Media
unevenly the rack system.
following precautions:
description of the PMs.
safe operation.

10BASE-FL mm1 Fiber 2.0km(6562 ft) FPM10-MST, FPM10-MSC
fiber connectors. This procedure applies to ports using an FPM-MSC, FPM-SSC single-
IEEE Standard Media Type Max. Distance 8000X Port Module
sgl.m2 Fiber 10.0km(65620ft) FPM10-SST, FPM10-SSC 100BASE-FX mm1 Fiber 200 m3 (650 ft) FPM-MSC, FPM-MST
sgl.m2 Fiber 200 m3 (650 ft) FPM-SSC 100BASE-SX (proposed, 850nm mm1) 150 m3 (500 ft) FPM-SXMST, -SXMSC -
1 mm = multi-mode 2 sgl.m = single-mode 3 max. each for two segments in a 100Mb collision domain. Single segment is 412m for FX and 300m for SX.
The following procedure applies to installations using an PM with
ST-type fiber connectors. This procedure applies to ports using an FPM-MST,
Receive (RX) port of the remote device. Begin with the color-coded strand of
(TX) port of the remote device. Use the non-color coded fiber strand for this.
has been established at both ends (and when power is ON in the unit). If LINK
The various media types supported along with the corresponding IEEE
small form factor “ “ FPM-MTRJ, FPM-MV45
The following procedure applies to installations using an PM with SC-type
FPM10-MST, FPM10-SST single-mode, FPM-SXMST, and to SPM-FDST.
is not lit after cable connection, the normal cause is improper cable polarity.
Swap the fiber cables at the Port Module connector to remedy this situation.
mode, FPM10-MSC, FPM10-SSC, FPM-SXMSC, and to SPM-FDSC and -FDSSC
10BASE-T & 100BASE-TX twisted pair 100m (328 ft) PM-RJ45, PM-RJ45U
tissue dampened in alcohol. Make certain the connectors are clean before
bands at regular intervals; you must use the color-coded strand on the
the tips of the connectors on the FPM. Save these dust caps for future use.
802.3 and 802.3u standards and connector types are as follows:
associated ports at each end of the fiber optic segment.
3.3 Connecting Fiber Optic ST-type, “twist-lock”
3.4 Connecting Fiber Optic SC-type, "Snap-In"
the cable for this first TX-to-RX connection.
connecting.
single-mode.
Copper:
Fiber:
short wavelength

fiber cable (9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode
The RJ-45 ports of the Magnum 8000X Dual-Speed Hubs can be connected to
10Mb and 100Mb) be used whenever possible in order to provide flexibility in a mixed-speed network, since dual-speed ports are auto-sensing for either 10
fiber port connectors. Single-mode fiber cable has a smaller diameter than multi-mode
where xx/xx are the diameters of the core and the core plus the cladding respectively).
The same procedures as for multi-mode fiber applies to single-mode fiber connectors.
3.6 Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or Shielded)
used when making 100BASE-TX connections. When the ports are used as 10BASE-T
square male connectors into the SC female jacks of the PM until it clicks and secures.
Twisted Pair (CAT 3, 4, 5) 10BASE-T RJ-45
When using single-mode fiber cable, be sure to use single-mode
Twisted Pair (CAT 5) 100BASE-TX RJ-45
100BASE-TX twisted pair segment to the RJ-45 port. The procedure is the
When connecting fiber media to SC connectors, simply snap on the two
ports, CAT 3 may be used. In either case, the maximum distance for unshielded
is shielded, either unshielded or shielded cables and wiring may be used.
illuminated when the unit is powered and proper connection is established
Single-mode fiber allows full bandwidth at longer distances, and may be used to
Media IEEE Standard Connector
The following procedure describes how to connect a 10BASE-T or
connect 10Mb nodes up to 10 Km apart, or 15Km with the SPM-FDSSC.
same for both unshielded and shielded twisted pair cables.
Follow the steps listed in Section 3.3 and 3.4 above.
3.5 Connecting Single-Mode Fiber Optic
twisted pair cabling is 100 meters (328 ft).
and 100Mb/s.

order to install an IEEE 802.3u compliant Fast Ethernet network, the collision domain .
Ethernet device component and the associated BT delay. A “DTE” is an end node, such
not help, ensure that the cable is connected properly and that the device on the
between any two devices in a single collision domain. A collision domain is defined as
Each Fast Ethernet device component also has an associated BT delay which
The 100Mbps Collision Domain Diameter is the length of the longest path
a cluster of network devices which are connected by means of a repeater or repeaters
such that no bridging devices are present between any two devices in the cluster. In
. regardless of the actual network topology . . must be less than 512 BT (Bit Times).
Fiber Optic 1.000 Shielded TP cable 1.112 Category 5 Cable 1.112 Category 3, 4 Cable 1.140 *Worst case delays taken from IEEE Std 802.3u-1995, actual delays may be less for a particular cable. Contact your cable supplier for exact cable specifications.
as a user station. Note that there is only one DTE pair associated with any device-to-
depends on the physical signaling system employed. Table 3.6.1b shows each Fast
Component Round-trip delay in Bit Times (BT)
**Note, the delay is only 80 Bit Times for the 8000X, front-port-to-front-port.
3.6.1 100Mbps Collision Domain Diameter, Cable Distances and PDV
Bit Time per Meter (BT/m)
Media Type Round-trip delay in
combination of TX and FX ports 92 **
2 TX DTEs 100 2 FX DTEs 100 1 FX and 1 TX DTE 100 1 T4 and 1 TX or FX DTE 127 Class I Repeater 140 Class II Repeater with any
Bit Times are related to media type as shown in Table 3.6.1a.
*Worst case delays taken from IEEE Std 802.3u -1995.
other end is powered on and is not defective.
device path.
Calculations

To determine whether a prospective network topology adheres to the collision
standard 100m Category 5 user cable segments (i.e. from computer to hub) and needs to
where 111 is the BT delay for 100m of Category 5 cable (1.112 BT/m* 100m), 80 is the
A typical example of a PDV calculation is shown below, and is illustrated in
Figure 3.6.1a. Here, an integrator wishes to cascade the 100Mbps collision domains of
know how long the inter-repeater Category 5 cable segment, used to cascade the hubs,
⇒ 25 m maximum total length for Category 5 inter-repeater segment,
domain diameter specification, the following formula should be applied to the worst
accommodate unexpected delays such as extra long patch cable. A safety margin of
two Magnum 8000X Mixed-Media Hubs (each having a PDV of 80 BT) for use with
BT delay for each Magnum 8000X , 100 is the BT delay for the TX DTE pair, and a
safety margin of 2 was used. Figure 3.6.1a: Two cascaded Magnum 8000X hubs
case path through the network. The worst case path is the path between the two Fast
adhere to IEEE standard, this value must be less than 512 BT. The safety margin is
PDV is the Path Delay Value of the worst case path. For the network to
specified in BT and may be a value between 0 and 5. This margin can be used to
can be. The variable “X” represents the unknown maximum cascade cable delay.
R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
PDV = X + ((111 + 111) + (80 + 80) + (100) + 2 ) BT < 512 BT
100 m Cat. 5 cables to user devices
(DTE pair delay) + (safety margin)
Twisted Pair cable length, TL < (28 BT) / (1.112 m/BT)
Ethernet devices (DTEs) which have the longest round-trip time.
ACT
COL
GAR RE TT
Cat. 5 cable for
512 > (X + 486) BT X < (512 - 486 ) BT, X < 28 BT
R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
100 m Cat. 5 cables to user devices
about 2 to 4 BT is recommended.
TL < 25 meters
ACT
COL
GAR RETT


meters may be used to cascade the Magnum 8000Xs. Note that this inter-repeater cable
cascade cable segment length. An illustration of this example is shown in Figure 3.6.1b,
In the above example, 75 is the BT delay for 70m of Category 5 cable (1.112 BT/m), 80
R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
the relatively shorter bit time (80 BT actually measured, for front-port-to-port) delay of
the Magnum 8000X vs. the industry standard delay of 92 BT for Class II repeaters. The
installation flexibility and network growth potential is accordingly better with Magnum
cable lengths for common network configurations using industry standard repeater PDV
The resulting value tells us that a Category 5 cable with a length of up to 25
It is also possible to cascade a group of up to nine Magnum 8000Xs (serving
up to 56 users with full-length 100m cables to each) by using short inter-repeater cable
is the bit time delay for each Magnum 8000X front-to-front ports, 100 is the BT delay
hub products normally allow. This additional cascading level and cable length is due to
2 meter Cat. 5 cable for cascading All user devices connected
standards normally permit, and is different from what competitive 100Mbps Class II
8000Xs than with hubs that merely meet the standard. Table 3.6.1c shows maximum
numbers. Calculations such as above should be performed using measured PDV data
segments. The following is an example of how to calculate the maximum allowable
where the hub-to-user cable lengths are up to 75 meters for Cat 5 twisted pair. The
length may be increased by shortening the lengths of the 100m hub-to-user cable
⇒ 2 meters (6 ft.) length max. for each of the cascade segments,
PDV = X + ((100) + (80 + 80 + 80 )+ (83 + 83) + 2 ) BT < 512 BT
variable “X”, the maximum hub-to-hub cable delay, is calculated as follows:
512 > (X + 508) BT, X < 4 BT Twisted pair user cable length, TL < (4 BT) / (1.112 m/BT)
R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
TL < 3.6 meters for two hub-to-hub cascading cables
supplied by the equipment manufacturer in important installations.
Magnum 8000X Mixed-Media hubs is a
stations, and 2 BT is the safety margin
Magnum 8000X Mixed-Media hubs
for the TX DTE pair in the user
capability beyond what industry
applied.
segments.


coding for the 100BASE-TX signaling system. When connecting a NIC to the 8000X, it
(Network Interface Cards) which support Auto-Negotiation. The Magnum 8000X will
communicating with a protocol other than 100BASE-TX (such as 10BASE-T). When
Instructions for connecting the Magnum 8000X Mixed-Media Hubs to the
The Magnum 8000X fiber Hub can be easily mounted on a table-top or any
When properly installed, the front-mounted LED status indicators should be in plain
brackets and screws (included with each 8000X unit). The brackets attach to the front
The Magnum 8000X Mixed-Media Hub will function properly with NICs
100Mb operation is agreed and in use, the 100Mb LINK/ACT LED is illuminated,
media fiber Hub in a 19” rack is a simple procedure. The units are 1U (1.70”) high.
establish link with any NIC which can send and receive the Fast Link Pulse (FLP)
may be necessary to reload the NIC drivers on the user device if the NIC has been
view and easy to read. Rack-mount installation requires special 19” rack-mounted
suitable horizontal surface, and has four rubber feet to provide stability without
R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
sides of the hub, which is then fastened into a standard 19” RETMA rack.
3.6.2 Connections to NICs which support Auto-Negotiation
various Fast Ethernet media are given in the following sections.
steady ON if no traffic or blinking when there is traffic.
3.7 Table-Top or Shelf Mounting
BRD
ACT
COL
GARRETT
scratching finished surfaces.
3.8 Rack-Mounting


replaced. In cases where additional PM cards are needed, the face plate for an available
front-mounted slot must be removed. The following procedure describes this operation.
The Magnum 8000X is normally received from the factory with all required
equipment) are sensitive to static discharge. Use proper ESD measures
The 23” brackets and ETSI brackets are also available (optional) for Rack-
PM modules installed. There may be situations where PM cards need to be added or
R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
R L S R L S R L S R L S R L R L R L R L R L R L R L R L R L R L R L R L
Fig 3.8 Multiple Magnum 8000X units rack-mounted in a 23”
mounting of Magnum 8000X Hubs. The 23” brackets are more popular in Telco
Failure to do so may result in damage to the unit
from the chassis before attempting to remove
Be sure the power cord is unplugged
attaching the brackets to the sides of the Magnum Switch unit.
and/or replace any PM cards.
and will void the warranty.
3.9.1 Preparation for Installing and Removing PMs
3.9 Port Module (PM) Installation
when handling port modules.
accessed in operation from both
rack-mounting purposes. The
are similar to the 19” brackets
The optional 23” brackets and
23” brackets are mainly used for larger equipment
but use metric dimensions.
the ETSI brackets come as a
pair in a package, along with
standard for Central Office
frames, and are frequently
the necessary screws for
industry where they are
sides.

front of the unit and a bonus slot for an SPM in the rear of the unit. A total of seventeen
top of the unit and two screws each on the left and right edges. Remove these
Looking down into the Magnum 8000X unit, notice that there are individual
PM connector sockets for each PM card position. There are 16 PM slots located on the
parts called “front-top” and “rear-top”. There are 6 screws located on front-
When the front-top cover has been removed, the front-interior is exposed.
To make the installation of port module easy, the top cover is made in two
screws. Once these are removed, the front-top cover is easily lifted off the

slots for seventeen Ethernet segment connections are available. The extreme left
header-position in front is used by the LED Status module. (See Figure 3.9.1b).
Media Connector with electronic
Cooling Fan Power Supply Board
chassis base.

(inserts into main board)
These screws are used to secure a PM face plate in position. These screws are also used
to secure the individual PM cards, which can be subjected to significant forces from the
On the bottom-front of the unit, there is one retaining screw for each PM card slot.

Up to sixteen front-mounted PM cards may be installed in one Magnum
PM card installation is covered in Section 3.9.2. PM card removal is covered in
8000X Fiber Hub unit. Follow these steps to install a PM.
3.9.2 Installing PM Cards in the Magnum 8000X
attached cables. (See Figure 3.9.1c)
individual PM card.
into the selected PM
Each PM card fits
slot. Align the
Sect.3.9.3.

connector pins on the bottom of the PM card with the connector socket inside
Once inserted, the PM card will be secured by the header connector,
To properly remove a PM card from the Fiber Hub, follow the 3 steps below.
see Figure 3.9.2b. (If you force the PM down when the pins are not properly
aligned with the holes in the header, the pins will become bent and the PM is
the unit. The pins are slightly angled to facilitate the installation. (Do NOT
carefully apply enough pressure to insert the PM card’s pins into position,
to be operational. When leaving PM slots empty, always use a face plate
port modules may fit easily in one port slot and be very hard to install in
(Magnum PM-FP) to cover the slot opening in the front panel. This will
maintain proper cooling air flow, safety, and operation as required by
PM front panel is guided into the front slot cut-out. Then, slowly and

the front panel port slot cut-out, and retaining screws.
straighten the pins before insertion !!)
the chassis cover should be replaced.
FCC, CE, and other regulations.
3.9.3 Removing PM Cards
damaged).
another.

On the bottom-front of the unit there is one retaining screws for each PM card
and face plate slot. These screws are used to secure a PM card in position (see
one that has been removed, follow the steps as described for installing an PM
several screws located on top front and back of the unit, and four screws each
If the slot from which the PM card has been removed is to remain unused, be
sure to install a PM face plate cover in it. If another PM card is replacing the
The 8000X chassis is connected with 20 screws on the top cover. There are
on the top left and right sides. Remove these 20 screws from the top edges.
Once these are removed, the top cover is easily lifted off the chassis base.

Gently pull the PM card up and out of the connector socket (see Figure

Figure 3.9.3a). Remove the front screws of the PM to be removed.
3.10 Preparation for Installing and Removing SPMs
card discussed in Section 3.9.1.
3.9.3b).

On the rear side of the unit there are two retaining screws for Bonus Port slot.
used to secure the SPM modules, which can be subjected to significant forces from the
These screws are used to secure an SPM face plate in position. These screws are also
Looking down into the Magnum 8000X unit, notice that there is one SPM

connector header located on the rear part of the main board. (See Figure 3.10b).

AC Power Connector Bonus Port Slot,
OFF
Screw Holding the SPM face plate
attached cables. (See Figure 3.10c)
P3 - Interface to unit above.
P4 - Interface to unit below.
the interior of the
unit is exposed.
IN

Jumper Settings For Half/Full duplex
There is only one SPM module may be installed in the Magnum 8000X Fiber
is then secured by the header connector. Re-insert the retaining screws on the
Align the 40-pin male header on the main board of the Magnum 8000X with
Magnum 8000X unit to be operational. When leaving SPM slots empty, always
the female sockets on the SPM module carefully. Any misalignment of the
use a face plate (supplied and factory-installed in all non-SPM units)) to cover
the slot opening in the rear panel. This will maintain proper cooling air flow for
either to half or full duplex. The SPM module, by default, comes with half-
SPM card installation is covered in Section 3.10.1, PM card removal in Sect3.10.2.
duplex settings. Finally the chassis cover should be replaced and screwed
Hub unit. The SPM bonus port slot is accessible on the rear of the unit
safety, and operation as required by FCC, CE, and other regulations.
a 8000X unit. The SPM module fits easily into the SPM header.
pins will prevent proper functioning of the SPM module.
3.10.1 Installing an SPM Module in the Magnum 8000X
SPM module cover plate to provide stability .
Follow these steps to install an SPM.
down.

Keep the face-plate screws available. Gently pull the SPM card up and out of
steps as described for installing an SPM card discussed in Section 3.10 on the
The Magnum 8000X incorporates an internal universal power supply, and has
On the rear side of the hub there are two retaining screws for the Bonus Port
removed is to remain unused, be sure to install an SPM face plate cover in it.
a male IEC connector for the AC power cord at the right-rear. A six foot 115vac power
the connector header . If the bonus port from which the SPM card has been
If another SPM card is replacing the one that has been removed, follow the
Non-standard screws may stop the fan from working, and the heat build-up may
To properly remove an SPM module from the Magnum 8000X Stackable
slot. These are used to secure an SPM module in position. Remove them.

3.10.2 Removing an SPM Bonus Port Module
Concentrator follow the three steps below.
See procedure in Section 3.10 above.
3.11 Powering the Magnum 8000X
cause serious hazard to the unit.
preceding pages.

voltage ranges from 90 - 260 volts with a power input frequency of between 47 - 63 Hz
and will consume no more than a maximum of 30 watts. The power connector is located
on the back of the unit. In order to power down the unit, simply unplug the unit’s power
cable In a stacked configuration, this will NOT affect the operation of other units in the
8000X unit. Individual segments of any media type can be connected or disconnected
stack. When connecting various Ethernet media, there is no need to power down the
cord is supplied with each unit. (Units shipped from the GCI factory to outside the
from PMs without concern for AC power -related problems or damage to the unit.
The Magnum 8000X supports installation environments where the AC
United States and Canada will not include a 115 vac power cord.)

When a collision signal is detected at a receiving port, it generates a jam pattern
good packets, the filter and forward decisions are made based on the destination address
following describes the basic functionality of the Magnum 8000X Fiber Hub.
The entire hub (or a stack of multiple units) counts as one Dual-Speed repeater.
or after 6.5 ms of continuous transmissions. Network integrity is checked every
There is no software set-up to be done at installation or for maintenance. The functions
Each time a packet is received on one domain of the bridge module, the decision is
contained in each packet. If the destination address is on the same domain from which
domain, then it is forwarded to the other domain. If it is a new node address coming in
which the switch did not previously know about, it “learns” the new address and puts it
multiple port segments within two (10 and 100Mbps) collision domains. The
optic and twisted pair segments. LINK is normally lit. Broken cables or a
8000X provides switched (bridged) connectivity between the Ethernet (10 Mbps) and Fast Ethernet (100Mbps) domains. It joins the two network domains for unified
taken to either to filter or forward the packet. Errored packets are always filtered. For
the packet originated, then it is filtered and not forwarded to the other domain. If the
destination address is not found to be a match in the address table for the originating
to the other ports. The sequence of jam signals depends on the sequence and
loss of power at any point in such segments will turn off the LINK LED.
The Magnum 8000X handles the two different traffic domains separately . The
utilization and performance. Magnum 8000Xs are hardware plug-and-play devices.
The Magnum 8000X operates as a Mixed-Media Ethernet Hub to support
operation, and filters/ forwards packets in both directions to maximize bandwidth
800 ms and segment (port) reconnection occurs after a 512-bit packet is transmitted without error.
in the correct port address table. See “Address Learning” for more details. This
The operation of the Magnum 8000X is described in this section.
diagram below shows the filter / forward logic for both domains.
of the Magnum 8000X are described in this manual.
4.2 Dual-Speed Functionality
4.1 Repeater Functionality
location of collisions.
4.0 Operation

in the 100Mb domain address table.
NOT in the 100Mb domain address table.
10 Mb Domain 100 Mb Domain
flushed periodically to update the network status and to purge any inactive stations from
By selectively forwarding packets from each domain to the other domain
the local traffic on each side contained, preventing unnecessary packets and bad packets
address table capacity of 8K addresses. With a large address table, a Magnum 8000X
can serve the needs of a medium-sized to large network. Table 4.2 shows what filter /
forward action the Magnum 8000X will take in each packet-processing situation, and
node-address packet comes into a port for the first time, then the new source address is
Packet Source Destination Address Table Filter/Forward
bandwidth for the users on both sides of the network. As shown in Figure 4.2, it keeps
from traveling to the other domain and using up bandwidth needlessly over there. This
The Magnum 8000X bridge module is a state machine design which has a total
when a new node address will be added to the internal Address Table. When a new
“learned” at the same time that the packet is forwarded. After learning, subsequent
packets from the same node address are routinely processed. The address tables are
based on its switching (bridging) logic, the Magnum 8000X increases the available
10 Mbps Not in table Not in table Add source to table Forward
10 Mbps In table Not in table None Forward
100Mbps Not in table Not in table Add source to table Forward
100Mbps In table Not in table None Forward
Source Address Address Maintenance Action
10 Mbps Not in table In table Add source to table Filter
10 Mbps In table In table None Filter
100Mbps Not in table In table Add source to table Filter
100Mbps In table In table None Filter
10 Mb Traffic 10 BUS 100
NOT in the 10Mb domain address table.
in the 10Mb domain address table.
the tables of both domains.
100 Mb Traffic · Bridge Module

results in more available network bandwidth on both sides and a throughput increase on
The Magnum 8000X Dual-Speed Hubs need no software set-up and are transparent
The PM-RJ45 and PM-RJ45U ports independently support auto-negotiation
should agree on the speed capability being signaled. The device connected, depending
When the ‘S’ LED is steady ON, the port has auto-negotiated for 100Mbps
8000X copper port is connected to a non-negotiating device, it will default to 10 Mbps speed. Since Magnum 8000Xs are hubs, front ports always operate in half-duplex
in is powered up. These are exceptions to the “negotiate at LINK – enabled” rule, but
The Magnum 8000X is equipped with six LEDs located on the front of the
chassis unit (see Figure 2.3b). These LEDs are Power (PWR), Bridge(BRD), Collision
(COL) and Activity (ACT) for 10 and 100Mbps speed. They are used to provide visual
indication about the operational condition and traffic activity of the 8000X unit and its
for shared 10BASE-T and 100BASE-TX modes. When the ‘S’ LED is flashing on a
port, it means that the hub is sending out auto-negotiation pulses on that port. When a
100Mb speed, and can send/receive auto-negotiation pulses, and . . . -- when the second of the two connected devices is powered up*, i.e., when LINK
operation and is running at 100Mbps. When it is steady OFF, it is at 10 Mbps. If a
LINK connection is initially made, the other device should respond and both sides
the devices at both ends of the cable are capable of operation at either 10Mb or
on what it is, will either signal that it is capable of 10 Mbps or 100Mbps speeds.
to system and application software, including network management software.
COL Flashes YELLOW to indicate a collision, one each for 10 and 100Mbps
-- when LINK is re-established on a port after being lost temporarily.
ACT Flashes for packet activity, one each for 10 and 100Mbps domains
PWR Illuminates GREEN to indicate that the unit is receiving power.
Auto-negotiation per-port for dual-speed hubs occurs when:
4.3 Auto-negotiation and speed-sensing
BR GREEN, Steady ON, unit has bridge inside
Silence means the port defaults to 10 Mbps.
Magnum 8000X chassis unit LEDs
may be occasionally encountered.
for all users on both domains.
is established for a port, or
4.4 Chassis LEDs
associated PM cards.
mode.
General information - · LED Description


mode 10 (5) 1300 9/125 -30 -39 7 14 13 26
mode 18+ (0.4) 1300 9/125 -15 -31 14 28 17.5 35
-31 9.0 5.5 3.0 2.0 15.8 12.2 5.5 4.0
mode 2 (0.4) 1300 62.5/125 -14 -31 15 5 16 5.7
mode 0.3 (0.3) 850 62.5/125 -12 -15 1 0.3 1.5 0.5
* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the
Receiver Sensitivity and Transmitter Power are the parameters necessary to
-31 9.0 5.5 2.5 2.0 14 12 5 4
-31 9.0 5.5 2.5 2.0 14 12 5 4
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,
compute the power budget. To calculate the power budget of different fiber media
The following data has been collected from component manufacturer’s (HP’s and
SPM (or equal external unit such as 300ES-FDX) must be used, and
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
Siemens’) web sites and catalogs to provide guidance to network designers and
installations using Magnum products, the following equations should be used:
4.5 Power Budget Calculations for 8000X FPM’s and Fiber Media
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
-23.5 -31
OPB (Optical Power Budget) = PT(min) - PR(min)
mode 2 (n.a.) 1300 62.5/125 50/125 -20
following factors are both applied:
passive Attenuation.
SPM-FDSC 100Mb FX Multi-
installers.

notify the carrier of any damage which you believe occurred during shipment
An important feature of the Magnum 8000X Hub is the use of individual Port
front port slots are designed to support all standard Ethernet media types at 10
Examine the shipping container for obvious damage prior to installing a PM;
or delivery. Inspect the contents of this package for any signs of damage and
need to return the unit, use the original shipping container if possible. Refer to
Remove the PM(s) from the shipping container. Be sure to keep the shipping
container should you need to ship any of the PMs separately at a later date.
In the event there are items missing or damaged contact your supplier. If you
media. Since the Magnum 8000X’s have dual-speed capability per-port, the
or 100Mps speed. Each PM provides one port for connecting one Ethernet
This section applies only to PMs shipped as separate items, i.e., PMs not
Modules (PMs) for flexible mixed-media connectivity to RJ-45 and fiber
For a list and brief illustration of Port Module types, refer to Section 2.4
This chapter describes each Port Module (PM), including appearance,
factory installed in a Magnum 8000X PM slot or in bonus port slot.
Each PM is individually described in the following sections.
segment with its individual connector type and media.
5.0 Introduction - Magnum 8000X Port Modules
ensure that the items listed below are included.
Chapter 5 for specific return procedures.
5.1 Inspecting the Package and Product
One or more PMs.
functionality, and status displays.
This package should contain:
5.2 Product Description

100BASE-FX, -SX and 10BASE-FL ST Connectors
5.2.1a FPM10-MST, 10 Mbps multi-mode FL-ST-type, “twist-lock” connector
5.2.1 FPM-MST, 100Mbps multi-mode FX-ST-type, “twist-lock” connector
equipped with a dual ST-type connector. It looks similar to the 100Mb FPM-MST, but
which indicates proper connectivity with the remote device when lit. Lettering on the
100BASE-FX, -SX and 10BASE-FL SC Connectors
front of the module identifies it as “100 FX” to avoid confusion with other similar-
The Magnum FPM10-MST is a multi-mode 10 Mbps fiber optic module
5.2.2 FPM-MSC 100Mbps multi-mode FX-SC-type, “snap-in” connector
The module is equipped with an Activity (A) LED, and a Link (L) LED
A L
has the lettering “10 Mb” on the front to distinguish it.
equipped with a dual ST-type connector. It
MST. It has the same LEDs indicating port
support 100BASE-FX network segments.
hub, it supports fiber optic cable distances
The Magnum FPM-MSC is also
activity (A), and Link (L) operational, and
these two modules is the same, the FPM-
MSC is equipped with an SC-type "snap-
multi-mode 100Mbps fiber optic module
functions as a fiber optics transceiver to
When installed in an 8000X half-duplex
transceiver module, similar to the FPM-
While the functionality of the
The Magnum FPM-MST is a
only up the IEEE-specified 100Mbps
in" connector instead of an ST-type.
a multi-mode 100Mbps fiber optic
the same face-plate lettering.
i.e., typically 200 meters.
looking FPMs.
shared-collision-domain distance limits,

identical to those of the FPM-MSC. To distinguish the single-mode FPM-SSC from the
equipped with a dual SC-type connector. It functions as a full fiber optic transceiver to
The Magnum FPM10-SSC is a single-mode 10 Mbps fiber optic module equipped with
5.2.2a FPM10-MSC, 10 Mbps multi-mode FL-SC-type, “snap-in” connector
equipped with a dual SC-type connector. It looks the same as the 100Mb FPM-MSC,
The FPM-SSC is equipped with an Activity (A) LED, and LINK(L) LEDs
multi-mode FPM-MSC, the label “Sgl. M.” is at the top of the faceplate of the FPM-
The Magnum FPM10-MSC is a multi-mode 10 Mbps fiber optic module
10Mbps modules in front ports (which can go up to 2Km), or use a 100Mbps full-
5.2.3a FPM10-SSC, 10Mbps single-mode FL-SC-type, “snap-in” connector
5.2.3 FPM-SSC 100Mbps single-mode FX-SC-type, “snap-in” connector
The Magnum FPM-SSC is a single-mode 100Mbps fiber optic module
a dual SC-type connector. It looks the same as the 100Mbps FPM-SSC, but has
100BASE-FX, 10BASEFL sgl.mode SC Connectors
duplex SPM in the bonus port which has no collision domain limits.
but has lettering “10 Mb” on the front to distinguish it.
lettering “10 Mbps” on the front to distinguish it.
already installed and must be used.
hub, supports fiber distances the
collision domain limitations, so
it is only practical for use where
installed in a Magnum 8000X
same as 100Mbps multi-mode
ports because of the 100Mbps
single-mode fiber cable is
networks.
SSC.
The FPM-SSC, when · support single-mode fiber

“small-form- ”
“small-form-factor”
mode FPM10-MST, the label “Sgl. M.” is at the top of the faceplate of the FPM10-SST.
The Magnum FPM10-SST is a single-mode 10 Mbps fiber optic module equipped with
a dual ST-type connector. To distinguish the single-mode FPM10-SST from the multi-
device. It has the same “100Mb FX” lettering on the faceplate. Note that the other end
5.2.3b FPM10-SST, 10Mbps single-mode FL-ST-type, “twist-lock” connector
Magnum FPM-MTRJ is a multi-mode fiber optic module equipped with a
ACTIVITY (A) and LINK (L) LEDs to indicate proper connectivity with the remote
small-form-factor MTRJ-type connector. It looks almost like an RJ-45 port, but it is
of the fiber cable may have a different connector, not necessarily an MT-RJ type.
5.2.5 FPM-MV45, 100Mbps multi-mode FX, VF-45 small-form-factor
5.2.4 FPM-MTRJ, 100Mb multi-mode FX, MTRJ small-form-factor
FX “small-form-factor” VF-45 connector used primarily
Magnum FPM-MV45 is a multi-mode fiber
distinctive because it has a tiny hinged door over the
in 100Mbps fiber-to-the-desktop links. Its size is
slightly larger. When not in use, its appearance is
similar to the MT-RJ port, but the VF-45 shell is
collision-domain distance limits, i.e., typically
The functionality of this 100BASE-
ease of connection make it a good choice for
half-duplex hub, it supports fiber optic cable
black in color. The MT-RJ’s small size and
FX multi-mode FPM is same as the ST and
SC-types, and it is equipped with the same
connectivity. When installed in an 8000X
distances only up the 100Mbps shared-
port hole to act as a dust cover.
200 meters.

(L) LED to indicate proper connectivity with the remote device, and an ACTIVITY (A)
The small size, about the same as an RJ-45, reduces the size of wiring panels
The cable port is a “plug-in” connector, with both fiber strands terminated in
one housing that cannot be improperly inserted. The module is equipped with a LINK
transmission connectivity up to 300m distance is suitable for the users requiring higher
When installed in a Magnum 8000X half-duplex hub, it supports fiber optic
cable distances only up the 100Mbps shared-collision-domain distance limits, i.e.,
5.2.6 FPM-SXMST and SXMSC (100BASE-SX) when available !!
100BASE-SX with ST Connectors
in wiring closets while providing the advantage of “future-proof” fiber optic
LED that flashes to show when Fast Ethernet packets are being received.
A L
cable to the FPM-SXMST is the same as other
ST-type “Twist-lock” connectors. The module
Ethernet,” looks essentially identical to other
based on 870 nm wavelength comes in multi-
LEDs to indicate proper connectivity with the
As an additional indicator, a multi-
mode SX port emits light (red in color) that is
in the visible spectrum and which can be seen
cheaper solution for Fast Ethernet fiber-to-
However, the connection of fiber
The FPM-SXMST port module,
ST and SC connectors. The FPM-SXMST
mode only, and may eventually become a
is equipped with Activity(A) and Link(L)
by looking into the port with the power on
better known as “short wavelength Fast
bandwidth in their LANs.
typically 200 meters.
the-desktop segments.
remote device.
technology.

length. It is equipped with a single RJ-45 connector and an Auto/100 switch. The RJ-45
connector is shielded to minimize emissions and will allow both unshielded twisted pair
The PM-RJ45 will support 10BASE-T unshielded twisted pair wiring (UTP)
standard for hubs-to-users twisted pair wiring: 1 = receive+, 2 = receive-,
3 = transmit+, 6 = transmit-, other pins not used. When the TP crossover switch is UP, the pins of the RJ-45 port are per the standard for up-links
and with no cable connected. The FX port emits light outside of the visible spectrum
The PM-RJ45 card supports Ethernet twisted pair segments of any standard
provided for user selection between operation in the auto-negotiation mode (Auto) or
transceiver functionality. The PM-RJ45 has ACTIVITY, LINK and SPEED LEDs.
(UTP) and shielded twisted pair (STP) cable connections. The Auto/100 switch is
The PM-RJ45U module is equipped with a Media Dependent Interface-
environments with maximum segment distances up to 100m (325 ft.), or shielded
twisted pair wiring (STP) of 150m (500 ft.). This module is designed with internal
Crossover (MDI-X) push switch to allow for cascaded connections. This feature
The RJ-45 pins normally (TP crossover switch DOWN) are per the
using twisted pair wiring, i.e., the transmit and the receive pairs are
A L S
IN for Up-Link connections to other hubs, etc.
fixed-at-100Mb (100) with no auto-negotiation and no 10 Mbps.
OUT for workstations and user connections.
5.2.7 PM-RJ45 and RJ45U (Twisted Pair)
and will always look dark to the human eye.
eliminates the need for a special twisted
cascaded and up-link connections (i.e.: a
connection to another repeater or hub or
concentrator typically.) When used for
other user device connections, the MDI-
X switch should be in the OUT position.
position, the PM-TP port is used for
segments going to workstations and
With the switch in the IN
pins not used.
pair crossover cable.

must be installed in
each empty PM slot.
empty front slots must be covered with the PM-FP face plate PM-FP
in order to maintain proper cooling air flow, and for safety, etc.
that must be installed in any empty PM slot.
When the Magnum 8000X chassis contains
The PM-FP is a blank face plate
less than twelve front-mounted PMs, the

of the procedures described in this section or if the Magnum 8000X Mixed-Media Fiber
Mixed-Media Fiber Hub product, it is recommended that the problem device is replaced
INSTALLATION, Section 2.6); the operation is also straightforward and is discussed
intended to help locate, identify and correct these types of problems. Please follow the
suggestions listed below prior to contacting your supplier. However, if you are unsure
the Installation Section of the applicable chapter of this manual. Also check
into a functioning electrical outlet. Use the PWR LEDs to verify each unit is receiving
with a known good device. Verify whether or not the problem is corrected. If not, go
to Step 5 below. If the problem is corrected, the Magnum 8000X Mixed-Media
of the Magnum 8000X Mixed-Media Fiber Hub unit or if unknown, contact
to make sure that the various components of the network are interoperable.
8000X Mixed-Media Fiber Hub unit. Be certain that each AC power cord is plugged
Hub is not performing as expected, do not attempt to repair the unit; instead contact
GarrettCom, Inc.by fax, phone or email (support@garrettcom.com) for assistance.
Should problems develop during installation or operation, this section is
connected and the cables/wires have not been crimped or in some way
impaired during installation. (About 90% of network downtime can be
All Magnum Ethernet products are designed to provide reliability and
consistently high performance in all network environments. The installation of
Magnum 8000X Mixed-Media Fiber Hub is a straightforward procedure (see
your supplier for assistance or contact GarrettCom Customer Support.
Fiber Hub and its associated cables are functioning properly.
attributed to wiring and connector problems.)
6.1 Before Calling for Assistance
in Section 4.
power.

including personal computers, workstations, terminals and printers; plus, the
d. Any particular application that, when used, appears to create the problem;
number(s). Include the date(s) that you purchased the products from your
to the occurrence of the problem. Any changes to system administration
Customer Service at (510) 438-9071 during business hours in California or email to
support@garrettcom.com). When calling, please have the following information
Authorization (RMA) number. To obtain an RMA number, call GarrettCom
All returns for repair must be accompanied by a Return Material
Failure symptoms, including a full description of the problem.
Please be prepared to provide the following information.
6.3 Return Material Authorization (RMA) Procedure
Name and phone number of your contact person.
Packing List Number (or Sales Order Number)
c. The components involved in the problem;
procedures should all be noted in this record.
a. The nature and duration of the problem;
b. Situations when the problem occurs;
various network media types being used.
Serial Number (or Invoice Number)
Name of your company / institution
6.2 When Calling for Assistance
supplier.
readily available:
Your shipping address · Date of installation · Product name

material. This material may cause electro-static shock damage to the unit.
sheet or bag for shipping protection. ( You may retain all connectors and
units under warranty. Testing and repair of product that is not under warranty will
Should you need to ship the unit back to GarrettCom, please follow these
replace components in the products that prove to be defective at no charge other
product has been damaged by misuse, misapplication, or as a result of service or
repair products that are under warranty at no charge, and will return the warranty-
condition causing the return cannot be duplicated by GarrettCom, the unit will be
GarrettCom reserves the right to charge for the testing of non-defective
This warranty will not be effective if, in the opinion of GarrettCom, the
Please complete the warranty card as this acts as a product registration,
GarrettCom will carefully test and evaluate all returned products, will
than shipping and handling, provided that the product is returned pre-paid to
inspecting any product returned for warranty repair which turns out not to be
During this warranty period, GarrettCom will repair or, at its option,
Information, Appendix A, for complete details). However, if the problem or
materials and workmanship for a period of three (3) years from the date of
GarrettCom, Inc. warrants its products to be free from defects in
GarrettCom reserves the right to make a charge for handling and
repaired units to the sender with shipping charges prepaid (see Warranty
and mail it to GarrettCom within two weeks of your purchase.
No Problem Found.
6.4 Shipping and Packaging Information
Attn.: Customer Service
213 Hammond Ave.
modification other than by GarrettCom.
this Installation Guide.)
GarrettCom, Inc.
result in a customer (user) charge.
shipment by GarrettCom.
GarrettCom.
returned as:
instructions:
faulty.
Fremont, CA 94539

Power Consumption: Model 8000X: 30 watt typical, 50 watts max.
B2.0 -48VDC, 24VDC & 125VDC POWER OPTION, THEORY OF OPERATION
8000X, its internal power supply, nor will it blow the fuse in the internal power supply.
The manual power “On-Off” Switch (optional) is used for powering the unit
48VDC, 24VDC & 125VDC power is used as the primary power source. The- 48VDC, 24VDC & 125VDC power configuration provides an Ethernet networking solution utilizing a special power supply in hubs with a proven track record.
B1.0 SPECIFICATIONS - FOR MAGNUM MIXED -MEDIA 8000X HUBS
Magnum 8000X-48VDC models are identical to those listed in the main manual.
The -48VDC, 24VDC & 125VDC power options are designed using diodes
companies include regular and wireless telephone service providers, Internet Service
With the exception of the power supply, all specifications and functions of
FUSE +
Magnum 8000X’s are easily installed in a variety of applications where -
Power Consumption: Model 8000X: 30 watt typical, 50 watts max.
Power Consumption: Model 8000X: 30 watt typical, 50 watts max.
correctly applied to the two inputs. It protects the 8000X from incorrect DC input
connections. An incorrect polarity connection, for example, will neither affect the
The –48VDC solution is particularly useful in the telecommunication
industry, where it is common for facilities to operate on -48VDC power. Such
Providers (ISPs) and other communication companies. In addition, many high
APPENDIX B : Internal DC Power Supply Option
DC Power Connector: 3 terminals: “ - “, “GND”, “+”
DC Power Connector: 3 terminals: “ - “, “GND”, “+”
DC Power Connector: 3 terminals: “ - “, “GND”, “+”
on and off when it is placed into or taken out of service.
A-
Power Supply (Internal 125 VDC Option)
Power Supply (Internal -48 VDC Option)
Power Supply (Internal 24 VDC Option)
connection terminals, so that the power
from an external source can only flow
into the unit. This allows the 8000X to
operate only whenever DC power is
inside on each DC power input line
behind the two external power

availability equipment services, such as broadcasters, publishers, newspaper operations,
operations in the event of a power failure. It is also frequently used for computer system
The 24VDC & 125VDC solution are particularly useful in the Industrial environment,
The actual connection procedure is very straightforward. Simply connect the
An ON-OFF manual switch is optional for DC power. This can be used to cut off power
In this picture, the -48VDC terminal block on the Magnum 8000X is located
125VDC solution is mainly used in power utilities, such as electrical substations, electrical generating plants, etc. The 24VDC applications are mainly in the Industrial
leads to the Magnum unit, beginning with ground. Ensure that each lead is securely
Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or
125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve”
similar for 24VDC and 125VDC options on the 8000X. The leads are identified as
voltage lead from 48V or –48V supply must be connected to the post labeled “+”.
brokerage firms and other facilities often use a battery backup system to maintain
36-70VDC
on the rear of the unit and is equipped with three (3) screw-down lead posts. It is
where it is common for facilities to operate on 24VDC or 125VDC power. The
environment, such as factory floor, HVAC equipment, military equipment, etc.
the user may elect to Ground either + or = terminal to suit the customer’s use.
ON
backup, management and operations monitoring equipment.
negative (-), positive (+), and chassis ground (GND).
located within 6 inches of the terminal block.
block on the Magnum 8000X. (see figure at
VDC, 24VDC & 125VDC power terminal
connections, and as a RESET for the Hub.
installation of the -48 VDC, 24VDC &
125VDC power source leads to the -48
This section describes the
B4.1 UL Requirements
the right).
tightened.

Power Consumption: Model 8000X: 30 watt typical, 50 watts max.
Power Consumption: Model 8000X: 30 watt typical, 50 watts max.
Power Consumption: Model 8000X: 30 watt typical, 50 watts max.
To order the optional –48VDC power supply factory installed, add a suffix of
C2.0 MAGNUM 8000X , with -48VDC, 24VDC & 125VDC Dual-Source option
“-48VDC” after the product’s standard model # Example: Magnum 8000X-48VDC.
Similarly, to order the optional 24VDC or 125VDC industrial specific power
standard model #. Example: Magnum 8000X-24VDC or Magnum 8000X-125VDC.
8000X-24VDC & 8000X-125VDC with this Dual-Source option are identical to those listed in the Magnum 8000X Fiber Hubs Installation and User Guide, including
supply factory installed, add a suffix of “–24VDC or “–125VDC” after the product’s
With the exception of the dual DC input power connections and the power
supply, all specifications and configuration options for the Magnum 8000X-48VDC,
Operation of the Magnum 8000X with the optional -48VDC, 24VDC &
Power Supply (Internal, -48VDC Dual-Source, model # Dual-Src48V)
Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src125V)
Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src24V)
125VDC power supply is identical to that of the AC-powered models.
B7.0 TROUBLESHOOTING Please refer to Section 6.0
Appendix B “Internal DC Power Supply Option”
B5.0 OPERATION

SUPPLY A+
FUSE +
GND
The Dual-Source DC power option is designed using diodes inside of the hub
b) The hub will not allow power to flow from a higher voltage input to a lower voltage input, i.e.
supply) because of the blocking action of the diodes. This is true even if one input connection
The hub models with the internal -48VDC, 24VDC &125VDC Dual-Source
The functionality of the Magnum 8000X-48VDC, 24VDC or 125VDC Dual-
Module, SNMP and stacking options are available for configuration with Dual-Source
rear of the unit and is equipped with five (5) screw-down lead posts (see Figure C5.0).
The primary terminals are identified as positive (A+), negative (A-), and the secondary
power terminals as negative (B-), positive (B+). The chassis “earth” or ground (GND),
power supply are designed for installations where a battery plant is the power source,
a) The hub can receive power from either input, “A” or “B”. The hub will normally draw its
c) When one correct DC input is present, the hub will receive power if the other DC input is
125VDC dual source leads to the -48VDC, 24VDC & 125VDC power terminal block on the Magnum 8000X hub (shown in Figure C4.0).
The -48VDC terminal block on the Magnum 8000X is located on the right
damage the hub or power supply internally (nor will it blow the fuse in the internal power
e) The hub will not receive power (and will not work) when both inputs are simultaneously
and where two separate power sources are utilized in order to increase operational
Option units. Refer to the main sections of this Installation and User Guide for a
d) Reverse polarity connections, if they should accidentally occur on either input, will not
This section describes the proper connection of the -48VDC, 24VDC &
Source Option hubs are identical to the standard AC-powered models. All Port
is a threaded post with a #6 nut. The dual source terminal block for 24VDC and
absent, or even if it is connected with reverse polarity or shorted or grounded.
power from the DC source with the highest voltage at a given time.
the two DC power sources are not mixed together by the hub.
is reversed while the hub is operating from the other source.
detailed description of the Magnum 8000X Hubs.
B-
B+
(behind the four external power connection
power is correctly applied to either or both
on each DC power input line. A diode is
terminals) so that power from an external
source can only flow into the hub. This
allows the hub to operate whenever DC
absent or are both incorrectly connected.
uptime and to simplify maintenance.
placed in each of the four input lines
125VDC are similar.
of the two inputs.

determine the lead which is more “+ve potential”. The more “+ve” voltage lead from
The connection procedure is straightforward. Simply connect the DC leads to
ground, so the user may elect to Ground either + or = terminal to suit the customer’s
always use a digital voltmeter to measure the output voltage of the power supply and
The 24VDC & 125VDC terminal block on Magnum 8000X is similar to that
Terminal Block on a Magnum 8000X 48VDC with Dual-Source option
The following must be adhered to in order to conform to UL requirements:
To order the optional Dual-Source -48VDC power supply factory installed,
order “Dual-Src-48V” as a separate line item following the product model.
the hub’s power terminals, positive (+) and negative (-) screws. The use of Ground
(GND) is optional; it connects to the hub chassis. Ensure that each lead is securely
or Dual-Src48V-SWITCH for model with ON-OFF switch
Similarly to order “Dual-Src 24V” or “Dual-Src 125V” as a separate line
or Dual-Src48V-SWITCH for model with ON-OFF switch
Before connecting to Terminal Block of –48VDC, 24VDC or 125VDC,
Dual-Src48V for regular model with no ON-OFF switch
Dual-Src48V for regular model with no ON-OFF switch
48V or –48V supply must be connected to the post labeled “+”.
located within 6 inches of the terminal block.
item following the product model.
described in the –48VDC info above.
A+ AB- B+
36-70VDC
C5.1 UL Requirements
tightened.
use.

Operation of the Dual-Source Magnum 8000X-48VDC, 24VDC & 125VDC
sections of the “Installation and User Guide” for more information on the basic hubs.
hub models are identical to that of the standard models. Please refer to the applicable
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.