Table of Contents 69 sections Managed Edge Switch · Installation and User Guide · Magnum 6KQE · Hardware · … ShowHide
Managed Edge Switchp.1Installation and User Guidep.1Magnum 6KQEp.1Hardwarep.1Email: [email protected]p.2Magnum ™ 6KQEp.2Phone (510) 438-9071p.2APPENDIX A: WARRANTY INFORMATION ......................................... 39p.51.1 Technical Specificationsp.61.0 SPECIFICATIONSp.6MODEL DESCRIPTIONp.91.2 Ordering Informationp.92.1 Inspecting the Package and Productp.112.0 INTRODUCTIONp.112.2 Product Description - Magnum 6KQE Managed Edge Switchp.122.2.1 Packet Prioritization, 802.1p QOSp.132.2.2 Frame Buffering and Flow Controlp.142.3 Managed Network Software for Magnum 6KQEp.152.4 Features and Benefitsp.162.5 Applicationsp.173.1 Locating Magnum 6KQE Switchesp.213.2.1 Connecting Twisted Pair (CAT3, CAT5, UTP or STP)p.223.2 Connecting Ethernet Mediap.223.2.2 Connecting Twisted Pair (CAT5e or better, UTP or STP)p.233.2.3 Connecting Single-Mode Fiber Opticp.233.2.4 Gigabit SFP (Small Form-factor Pluggable) Transceiversp.243.2.5 Connecting Fiber Optic Cable to SFP Transceiversp.243.3 Mounting Dimensions for 6KQE with metal bracketsp.253.3.1 DIN-Rail Mounting the Magnum 6KQEp.263.4 Powering the Magnum 6KQE Managed Edge Switchp.273.5 Alarm Contacts for monitoring internal power, and Softwarep.28Trapsp.283.6.1 RS-232 (DB-9) Console port (Serial port) pin assignmentsp.293.6 Connecting the Console Terminal to Magnum 6KQEp.29Pin Signal Descriptionp.294.1 Switching Functionalityp.304.0 OPERATIONp.304.3 Flow-control, IEEE 802.3x standardp.324.4 Power Budget Calculations for 6KQE Modules with Fiber Mediap.335.0 Magnum 6KQE Managed Edge Switch Port Modulesp.335.1.1 6KQE Module LED designationsp.345.1.3 6KQE4-RJ45, 4 x 10/100Mb RJ45 (Slot C)p.355.1.2 6KQE Base Unit LED designationsp.355.1.4 6KQE4-1MMRJ, 1 x MTRJ / 3 x RJ45 (Slot C)p.365.1.5 6KQE4-2MMRJ, 2 x MTRJ / 2 x RJ45 (Slot C)p.375.1.7 6KQE4-1MLC, 1 x LC / 3 x RJ45 (Slot C)p.385.1.10 6KQE4-xSLC, LC Singlemode (20km) / RJ45 Modulep.395.1.11 6KQF-xSLCL, LC Singlemode (40km) / RJ45 Modulep.395.1.8 6KQE4-2MLC, 2 x LC / 2 x RJ45 (Slot C)p.395.1.12 6KQE-2GCU, 1GCU (Gigabit RJ45 Copper ports) (Slot D)p.405.1.13 6KQE-2GSFP, 1GSFP (Gigabit SFP Fiber ports) (Slot D)p.405.2 6KQEP-48VDC, Base Unit w/PoE Power-pass-throughp.416.1 Before Calling for Assistancep.426.2 When Calling for Assistancep.426.0 TROUBLESHOOTINGp.42CAUTION : Do not pack the unit in Styrofoam "popcorn" type packingp.44APPENDIX A: WARRANTY INFORMATIONp.446.4 Shipping and Packaging Informationp.44APPENDIX B : DC Power Inputp.45B3.0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHESp.46CAUTION: 48VDC products shall be installed with a readily accessiblep.47B6.0 TROUBLESHOOTINGp.47B5.0 OPERATIONp.47C1.0 SPECIFICATIONS - FOR MAGNUM 6KQE EDGE SWITCHp.48APPENDIX C: Internal DC Dual-Source Power Input Optionp.48C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGNp.49C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATIONp.49C5.0 INSTALLATIONp.49C6.0 ORDERING INFORMATION FOR DUAL SOURCE POWERp.50
Page 1 of the GarrettCom 6KQE user manual — Magnum 6KQE
Page 1 · click to enlarge
Page 1
GarrettCom 6KQE — Managed Edge Switch diagram (page 1)
Fig. 1 · Managed Edge Switch

Managed Edge Switch

Installation and User Guide

GarrettCom 6KQE — Managed Edge Switch diagram (page 1)
Fig. 2 · Managed Edge Switch

Magnum 6KQE

Hardware

Page 2 of the GarrettCom 6KQE user manual — Hardware
Page 2 · click to enlarge
Page 2

Copyright © 2009 GarrettCom, Inc. All rights reserved. No part of this publication may be

serviceable parts. Attempted service by unauthorized personnel shall render all

GarrettCom, Inc. reserves the right to change specifications, performance characteristics

Please use the mailing address, phone and fax numbers and email address listed below:

warranties null and void. If problems are experienced with Magnum 6KQE

GarrettCom is a registered trademark and Magnum, Dymec, DynaStar, Personal

Switch, Link-Loss-Learn, S-Ring, Convenient Switch and Converter Switch

Installation and User Guide

reproduced without prior written permission from GarrettCom, Inc.

Websitehttp://www.GarrettCom.com

Email: [email protected]

Managed Edge Switch

Switch products, consult Section 6, Trouble Shooting.

47823 Westinghouse Dr. Fremont, CA 94539-7437

Magnum ™ 6KQE

GarrettCom, Inc.

Phone (510) 438-9071

Part #84-00182Z (Rev. A)

UL is a registered trademark of Underwriters Laboratories

Hardware

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

Printed in the United States of America

and/or model offerings without notice.

are trademarks of GarrettCom, Inc.

Fax (510) 438-9072 · Contacting GarrettCom, Inc · Trademarks

Page 3 of the GarrettCom 6KQE user manual — Email: support@garrettcom.com
Page 3 · click to enlarge
Page 3

This equipment generates uses and can radiate frequency energy and if not

installed and used properly in strict accordance with the manufacturer's instructions, may

cause interference to radio communication. It has been tested and found to comply with the

limits for a Class A computing device in accordance with the specifications in Subpart J of

Part 15 of FCC rules, which are designed to provide reasonable protection against such

interference when operated in a commercial environment. Operation of this equipment in a

residential area is likely to cause interference, in which case the user, at their own expense,

will be required to take whatever measures may be required to correct the interference.

which has suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable

Cet appareil respecte toutes les exigences du Réglement sur le matériel du

ONLY be replaced by GarrettCom personnel through the RMA process.

2. 48VDC products shall be installed with a readily accessible disconnect device in the building installation supply circuit to the product.
3. This product shall be provided with a maximum 10A DC Listed fuse or
4. The external power supply for DC units shall be Listed, Direct Plug In

power unit, marked Class 2, or listed ITE Power Supply, marked LPS,

5. Product does not contain user replaceable fuses. Any internal fuses can

This Class A digital apparatus meets all requirements of the Canadian

1. This product is to be installed Only in Restricted Access Areas

(Dedicated Equipment Rooms, Electrical Closets, or the like).

circuit breaker in the supply circuit when connected to a 48V

Radio Frequency Interference Statement

Interference-Causing Equipment Regulations.

Canada. Cet appareil est Classe A.

Electrical Safety requirements:

rated output current.

centralized source.

Federal Communications Commission · Canadian Emissions Statement

Page 4 of the GarrettCom 6KQE user manual — Email: support@garrettcom.com
Page 4 · click to enlarge
Page 4
Page 4 of the GarrettCom 6KQE user manual — Email: support@garrettcom.com
Page 5 of the GarrettCom 6KQE user manual — APPENDIX A: WARRANTY INFORMATION ......................................... 39
Page 5 · click to enlarge
Page 5

5.1.11 6KQF-xSLCL, LC Singlemode (40km) / RJ45 Module 34 5.1.12 6KQE-2GCU, 1GCU (Gigabit RJ45 Copper ports) (Slot D) 35 5.1.13 6KQE-2GSFP, 1GSFP (Gigabit SFP Fiber ports) (Slot D) 35 5.2 6KQEP-48VDC, Base Unit w/PoE Power-pass-through 36

6.0 TROUBLESHOOTING 37

6.1 Before Calling for Assistance 37

6.2 When Calling for Assistance 37

6.3 Return Material Authorization (RMA) Procedure 38

6.4 Shipping and Packaging Information 39

APPENDIX A: WARRANTY INFORMATION 39

APPENDIX BDC Power Input .................................................................... 40
APPENDIX CInternal DC Dual-Source Power Input Option .................. 43
Rev. A 02/09Initial Release

Revisions:

Page 6 of the GarrettCom 6KQE user manual — 1.1 Technical Specifications
Page 6 · click to enlarge
Page 6
Switching Processing TypeStore and Forward with IEEE 802.3x full-

100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft)

Unshielded twisted pair - 100 m (328 ft)

10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)

10BASE-FL single-mode fiber optic - 10 km (32,810 ft)

10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)

100BASE-TX (CAT 5 UTP) - 100 m (328 ft)

100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft)

100BASE-FX, full-duplex, single-mode - 20.0 km (66K ft)

Packet buffer size240KB for 10/100 and 120KB for 1000Mb

100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft)

100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)

1000BASE-T (CAT5e or higher is recommended) - 100m (328 ft) 1000BASE-SX, full-duplex, multi-mode (62.5μm cable) - 220m

Shielded twisted pair - 150 m (492 ft)

Shielded twisted pair - 150 m (492 ft)

Address Table Capacity4K node, self-learning with address aging

15 μs + packet time (10 to 10 Mbps, and 10 to 100Mbps)

Throughput with 8 10/100 and 2Glink max.- 4.17M pps (Transmit)

IEEE 802.3z1000BASE-X Ethernet (Auto-negotiation)

Maximum Standard Gigabit Ethernet Segment Lengths:

Data Rate10Mbps, 100Mbps and 1000Mbps

Maximum Standard Fast Ethernet Segment Lengths:

IEEE 802.1xPort based Network access control
Gigabit Ethernet (1000Mb)1,488,000 pps

Network Standards and Compliance, hardware

Ethernet V1.0/V2.0 IEEE 802.310BASE-T,
IEEE 802.3adLink Aggregation (Trunking)

Maximum 10 Mbps Ethernet Segment Lengths

duplex flow -control, non-blocking

Latency5 μ s + packet time (100 to 100Mbps)
IEEE 802.1wRapid Spanning tree protocol
IEEE 802.3u100Base-TX, 100BASE-FX
Fast Ethernet (100Mb)148,800 pps

Back plane- 2.66Gb/s per slot

IEEE 802.3ab1000BASE-X Ethernet
IEEE 802.1dSpanning tree protocol
IEEE 802.3afPower over Ethernet

Filtering / Forwarding Rate:

Ethernet (10Mb)14,880 pps
IEEE 802.1pPriority protocol
IEEE 802.1qVLAN Tagging
IEEE 802.3xFlow Control

1.1 Technical Specifications

1.0 SPECIFICATIONS

Performance

Page 7 of the GarrettCom 6KQE user manual — 1.1 Technical Specifications
Page 7 · click to enlarge
Page 7
Cooling methodConvection, fully-enclosed ribbed-surface aluminum case

-40° to 140° F (-40° to 60°C) for UL60950 and Component Parts rating

-40° to 195° F (-40° to 85°C) for IEC 60068 Type Test short term rating

used as a sink, designed for vertical mounting, no fans

Fiber Port, MTRJ-type (plug-in)SFF Fiber multi-mode 100BASE-FX

1000BASE-SX, full-duplex, multi-mode (50μm cable) - 550m 1000BASE-LX, full-duplex, multi-mode (50, 62.5μm cable) - 550m 1000BASE-LX, full-duplex, single-mode (9μm cable) - 5km 1000BASE-ZX, full duplex, single-mode (9μm cable) - >70km Fiber Multi-mode connector types supported:

Fiber Port, LC-type (plug-in)SFF Fiber multi-mode 100BASE-FX

LEDs: Per Port (one set at the port, one set on swivel top on right side)

12VDC Power Input nominal (range 8 to 18VDC)

Conformal Coating (humidity protection) optional: Request quote

One NC indicating internal power, one NC software controllable

Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX

(see section 5.1.1 and 5.1.2 for detailed LED configurations)

Ambient Relative Humidity5% to 95% (non-condensing)

125VDC Power Input nominal (range 88 to 150VDC) 250VDC Power Input nominal (range 160 to 300VDC) Std. Terminal Block : “ -, GND, + ”

24VDC Power Input nominal (range 18 to 36VDC) -48VDC Power Input nominal (range 36 to 60VDC)

Storage Temperature-60 ° to 210 ° F (-50 ° to 100 ° C)

17.4 cm H x 19.1 cm W x 5.08 cm D

DC Power Supply (Internal, floating ground design)

Dimensions6.85 in. H x 7.5 in. W x 2.0 in. D
EnclosureHigh strength extruded aluminum
Altitude-200 to 13,000 ft. (-60 to 4000m)

Fiber Port, 1000BASE-SX, SFP modules

Fiber Port, 1000BASE-LX, SFP modules

Serial DB-9, see details at sec. 3.6

Fiber Single-mode connector types:

Weight3 lbs. (1.3 kg)

Ambient Temperature:

Show 4 more labels / short text on this page
Management Console connector · Operating Environment · Alarm Relay Contacts · Packaging
Page 8 of the GarrettCom 6KQE user manual — 1.1 Technical Specifications
Page 8 · click to enlarge
Page 8

A Dual-Source option is available for the 12VDC, 24VDC, –48VDC, and 125VDC

and 250VDC models. This provides for continuity of operation when either of the

IEEE 1613 Class 2 Environmental Standard for Electric Power Substations

See also Note for Power Substations in Section 3.2.1, 3.6.1, and 5.1.3

IEC 61850 EMC and Operating Conditions Class C for Power Substations

NEMA TS-2 and TEES for DC-powered and PoE-powered traffic control

Vertical mounting normal. Suitable for wall or DIN-Rail mounting (6KQE)

WarrantyThree years, per UL 60950 temperature rating Made in USA

UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class A

http://www.garrettcom.com/techsupport/insertion_guides/6kqecg.pdf

Class1 Division 2 and ATEX for hazardous locations, pending

The Dual-Source Terminal Block is marked : “ +A, -A, -B, +B ”

20 watts Max. (for a fully loaded fiber model with 2Gb) 15 watts Max. (for 8 port copper and 100Mb fiber model)

Email info@GarrettCom.com for additional information.

100-240VAC Power Input, 47 to 63 Hz (auto-ranging)

DC input sources is interrupted. See Appendices B and C.

AC Power ConnectorIEC-type, male recessed

See the Configuration Guide on the GCI web site at

Agency Approvals and Standards Compliance:

NEBS Level 3 and ETSI Compliant

Dual DC Power Input (Optional)

for configurations and options..

AC Power Supply (Internal)

Power Consumption:

6KQE Mounting:

equipment

Page 9 of the GarrettCom 6KQE user manual — 1.2 Ordering Information
Page 9 · click to enlarge
Page 9
Magnum 6KQEP-48VDCPoE, same as 6KQE-48VDC except the four 10/100 ports are

10/100 copper ports. Up to 3 100Mb fiber ports or up to four more 10/100 copper ports (or combinations) may also be configured, and up to 2 Gb ports are optional.

Please use this URL: for the complete Configuration Guide for the Magnum 6KQE.

(Slot C is 10/100 RJ-45 or 100Mb Fiber only)

Magnum 6KQE-24VDCMagnum 6KQE Managed Edge Switch, base unit with four
Magnum 6KQE-12VDCSame as 6KQE-24VDC except the power input is 12VDC
Magnum 6KQE-48VDCSame as 6KQE-24VDC except the power input is -48VDC
Magnum 6KQE-125VDCSame as 6KQE-24VDC except the power input is 125VDC
Magnum 6KQE-250VDCSame as 6KQE-24VDC except the power input is 250VDC

For licensed managed networks software (MNS-6K, RS-Ring and S-Ring) including

6KQE4-1SLC adds three 10/100 copper and one SM 20Km 100Mb LC fiber ports

6KQE4-3SLC adds one 10/100 copper and three SM 20Km 100Mb LC fiber ports

6KQF-1SLCL adds three 10/100 copper and one SM 40Km 100Mb LC fiber ports

6KQF-3SLCL adds one 10/100 copper and three SM 40Km 100Mb LC fiber ports

GUIs for ease-of-use and industry-leading security features, see separate data sheets.

Each Magnum 6KQE base unit may be configured with a choice of 2 modular slots.

6KQE4-2SLC adds two 10/100 copper and two SM 20Km 100Mb LC fiber ports

6KQF-2SLCL adds two 10/100 copper and two SM 40Km 100Mb LC fiber ports

6KQE4-1MMRJ adds three 10/100 copper and one MM 100Mb MTRJ fiber ports

6KQE4-2MMRJ adds two 10/100 copper and two MM 100Mb MTRJ fiber ports

6KQE4-3MMRJ adds one 10/100 copper and three MM 100Mb MTRJ fiber ports

6KQE4-1MLC adds three 10/100 copper and one MM 100Mb LC fiber ports

6KQE4-3MLC adds one 10/100 copper and three MM 100Mb LC fiber ports

6KQE4-2MLC adds two 10/100 copper and two MM 100Mb LC fiber ports

Magnum 6KQE-ACSame as 6KQE-24VDC except the power input is

Heavy duty metal case, IP53 for environmental protection, no fans.

http://www.garrettcom.com/techsupport/insertion_guides/6kqecg.pdf

MM= Multi-mode fiber SM= Single-mode fiber

AC 100 to 240VAC, 47 to 63 Hz

Following modules can be configured in Slot C only

6KQE4-RJ45 adds four 10/100 copper ports

MODEL DESCRIPTION

Magnum 6KQE (Slot C) Port Modules:

1.2 Ordering Information

Configuration Options:

PoE-enabled, data pairs

Page 10 of the GarrettCom 6KQE user manual — MODEL DESCRIPTION
Page 10 · click to enlarge
Page 10

Gigabit (1000Mb) SFP (Small Form Pluggable) Transceiver option (6KQE)

S-RING KeyS-Ring and RS-Ring Redundancy Manager licensed software for redundant

6KQE-2GSFP adds two SFP pluggable open transceiver ports for user selectable SFP

GarrettCom 6KQE — MODEL DESCRIPTION diagram (page 10)
Fig. 3

6KQE-1GSFP adds one SFP pluggable open transceiver port for user selectable SFP

ring management. One S-Ring or RS-Ring key is for licensed use one 6K-managed self

CONSOLE CBLConsole attachment cable. Serial null modem (aka X-modem) cable
CONFORM14 CRMConformal coating, heavy duty silicone at 14 mil thickness, for

Following modules can be configured in Slot D only (Slot D is Gigabit Fiber only)

DIN-RAIL-6KQDin-Rail mount for a secure vertical mount, with screws for 6KQE
KQ-CABLE-BKTMetal bracket for 6KQE, used for cable strain relief, for vertical
CONFORM05 CRMConformal coating, heavy duty silicone at 5 mil thickness, for

MNS-6K License- MNS-6K managed software is pre-loaded from the factory.

SFP-LX10 Gb SFP transceiver, 1000Mb-LX, 1310nm wavelength, 10Km

SFP-LX25 Gb SFP transceiver, 1000Mb-LX, 1310nm wavelength, 25Km

SFP-ZX40 Gb SFP transceiver, 1000Mb-ZX, 1550nm wavelength, 40Km

SFP-ZX70 Gb SFP transceiver, 1000Mb-ZX, 1550nm wavelength, 70Km

SFP-SX Gb SFP transceiver, 1000Mb-SX, 850nm wavelength, 550m

SFP-ESX Gb SFP transceiver, 1000Mb, 1310nm wavelength, 2Km

6KQE-2GCU adds two auto-negotiating 10/100/1000Mb copper ports

6KQE-1GCU adds one auto-negotiating 10/100/1000Mb copper port

Dual-SRCTwo separate power inputs (12/24/48, 125 or 250VDC)
CONSOLE USBSame as above, but with USB connector

interior PCBs, PS and modules (for moisture protection)

interior PCBs, PS and modules (for oil and gas industry)

Magnum 6KQE (Slot D) Port Modules:

Gb transceivers in each

with DB-9 connectors.

healing Ring.

Gb transceiver · mount

Page 11 of the GarrettCom 6KQE user manual — 2.0 INTRODUCTION
Page 11 · click to enlarge
Page 11

In the event there are items missing or damaged, contact the party from whom

product; notify the carrier of any damage that you believe occurred during shipment or

delivery. Inspect the contents of this package for any signs of damage and ensure that

Remove the items from the shipping container. Be sure to keep the shipping

shipping container if possible. Refer to Section 6, Troubleshooting, for specific return

Examine the shipping container for obvious damage prior to installing this

2 Set of two metal vertical mounting brackets, with screws to the case

you purchased the product. If the unit needs to be returned, please use the original

(configured with user-selected port module options installed)

1 Magnum 6KQE Managed Edge Switch, base unit

1 6KQE Installation and User Guide (this manual)

container should you need to re-ship the unit at a later date.

2.1 Inspecting the Package and Product

This package should contain:

the items listed below are included.

2.0 INTRODUCTION

procedures.

Page 12 of the GarrettCom 6KQE user manual — 2.2 Product Description - Magnum 6KQE Managed Edge Switch
Page 12 · click to enlarge
Page 12

Magnum™ 6KQE Managed Edge Switches provide configurability in an entry-

10/100 copper ports (which may be either regular or PoE). Up to 3 100Mb fiber ports or up to four more 10/100 copper ports or combinations, may also be configured. In

software. (MNS-6K-SECURE optional) See the Managed Networks Software (MNS-6K)

level industrial-grade package. The high performance 6KQE base unit comes with four

addition, one or two Gb ports may be configured as 10/100/1000 copper or SFP fiber in

Magnum 6KQEs are ideal for building a switched, hardened Ethernet network

infrastructure, connecting edge devices such as PLCs and IEDs with upstream switches

or routers. Designed for use in industrial applications such as factory floors and control

Advanced thermal design techniques with ribbed–surface Aluminum cases for

mounting, the hardened Magnum 6KQE is a “multi-purpose” Industrial Ethernet Switch.

6KQE handles stressful workloads (mixes of bursty data traffic and priority streaming traffic) as well as harsh environmental conditions.

maximum heat dissipation and a sealed case design enables the unit to operate in harsh

Industrial grade environments efficiently. Heavy duty Ethernet Switch jobs are readily

Component Parts method, or -40˚C to 85˚C by the IEC 60068 Type-Test method. With

Magnum 6KQE comes with the best-of-breed MNS-6K managed networks

tariffed carrier field facilities, or transportation and oil and gas, the rugged Magnum

2.2 Product Description - Magnum 6KQE Managed Edge Switch

cabinets, industrial video surveillance systems with PoE, power utility substations,

accommodated with an extended temperature rating of -40˚C to 60˚C by the UL

options such as several popular DC power input types, AC power and DIN-Rail

GarrettCom 6KQE — 2.2 Product Description - Magnum 6KQE Managed Edge Switch diagram (page 12)
Fig. 4 · 2.2 Product Description - Magnum 6KQE Managed Edge S…

http://www.garrettcom.com/techsupport/software/datasheets/mns6kds.pdf

datasheet for more information at

any 6KQE base unit.

Page 13 of the GarrettCom 6KQE user manual — 2.2.1 Packet Prioritization, 802.1p QOS
Page 13 · click to enlarge
Page 13

PoE base unit (6KQEP-48VDC) on Slot A and allows the users to utilize up to 4-ports of

feature supports the 802.3af PoE PSE standard for over-current protection, under-current

Magnum 6KQE Managed Edge Switches have heavy-duty aluminum cases and

and fulfills its role in support of QOS, giving packet processing priority to priority tagged

wireless access points, IP phones) that comply with the IEEE 802.3af PoE standard. The

play” and are designed for use in connecting edge devices such as PLCs, IEDs and PoE

video cameras with upstream switches and routers where a mix of bursty data traffic and

priority streaming traffic for video surveillance and cell-tower applications are present.

DC power options are available. Internal AC power and DC power input types may be

hardware and software through traps, providing a record of any losses of power signals

users from datagram paths that go all across a network. As a LAN device, the Magnum

packets according to the 802.1p standard. In addition to hardware support for QOS, the

The 6KQE managed switches also provides a PoE option via power –inside

PoE to support 802.3af Powered devices. See details for PoE base unit in sec 5.2. The

Power Sourcing Equipment (PSE) is fully compatible with Powered Devices (PD)(e.g

High performance features include non-blocking unicast traffic speed on all

are readily available with standard Industrial grade 24VDC power. Alternative internal

12V, 24V, 48V, 125V, 250V and dual source DC input is optional on the 6KQE. Alarm Relay contacts provided on each Magnum 6KQE Switch monitor the

The Magnum 6KQE switching hardware supports the IEEE 802.1p standard

PoE switch ports have an auto-sensing algorithm, so that they provide power only to

802.3af, PoE end devices. PoE is managed by a multi-stage handshake to protect equipment from damage and to manage power budgets.The PoE ports will

discontinue supplying power when the PoE powered devices are disconnected. This

ports and 802.1p QoS Traffic Prioritization. Magnum 6KQE switches are “plug-and-

Quality of Service means providing consistent predictable data delivery to

MNS software (R2) supports two priority queues that can be shared across the eight

levels of defined packet priorities for application-specific priority control by the user

6KQE can do its part to prevent any QOS degradation while it is handling Ethernet traffic through its ports and buffers.

and other user- defined software events. See Section 3.5 for details.

2.2.1 Packet Prioritization, 802.1p QOS

through software configuration settings.

detection, and fault protection.

Page 14 of the GarrettCom 6KQE user manual — 2.2.2 Frame Buffering and Flow Control
Page 14 · click to enlarge
Page 14

CRC, i.e., are good packets. This eliminates the propagation of bad packets, enabling all

impose minimal frame latency, they will also permit bad frames to propagate out to the

traffic. Since there is no way to filter frames with a bad CRC (the entire frame must be

forwarding is greater traffic congestion, especially at peak activity. Since collisions and

Magnum 6KQE’s are store-and-forward switches. Each frame (or packet) is

Ethernet segments connected. The "cut-through" technique permits collision fragment

frames (which are a result of late collisions) to be forwarded which add to the network

operation is that more bandwidth is available for good packets when the traffic load is

temporarily stop sending traffic, which allows the traffic to catch-up without dropping

Another feature implemented in the Magnum 6KQE Switches is a collision-

based flow-control mechanism (when operating at half-duplex only). When the Switch

entering by forcing a collision signal on all receiving half-duplex ports in order to stop

technique ensures that all forwarded frames are of a valid length and have the correct

When the Magnum 6KQE Switch detects that its free buffer queue space is

low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the

detects that its free buffer queue space is low, the Switch prevents more frames from

loaded into the Switch’s memory and inspected before forwarding can occur. This

While other switching technologies (such as "cut-through" or "express")

present in order for CRC to be calculated), the result of indiscriminate cut-through

devices sending it packets to cause “flow control”. This tells the sending devices to

packets. Then, normal packet buffering and processing resumes. This flow-control

bad packets are more likely when traffic is heavy, the result of store-and-forward

sequence occurs in a small fraction of a second and is transparent to an observer.

of the available bandwidth to be used for valid information.

2.2.2 Frame Buffering and Flow Control

incoming traffic.

greatest.

Page 15 of the GarrettCom 6KQE user manual — 2.3 Managed Network Software for Magnum 6KQE
Page 15 · click to enlarge
Page 15

All MNS-6K software information, and the documentation related to MNS-6K and MNS-

Managed Switch and implements security features and other software enabled features.

v4.1.4 firmware or higher version only, or MNS-6K-SECURE v14.1.4 firmware or

higher version only. Using any earlier MNS-6K versions will not support the 6KQE

Software User guide in pdf format, a separate document normally accessible via your

For interactive training software which shows basic and advanced info about

the Magnum MNS-6K management software and for a useful tool for first time users,

(NOTEMagnum 6KQE managed switch will work with MNS-6K Rel

www.GarrettCom.com/techsupport/index.htm#software and look for the

SECURE Rel v14.1.4, which allow the user to configure the Magnum 6KQE as a

For additional information about MNS-6K, see the Magnum MNS-6K

Magnum 6KQE comes with licensed MNS-6K Rel v4.1.4 software or MNS-6K-

Alternatively, for the latest documentation and information, or needed

You may also email: info@GarrettCom.com for further information.

2.3 Managed Network Software for Magnum 6KQE

6K-SECURE software, can be accessed at GarrettCom’s FTP site.

or FTP client program at ftp.GarrettCom.com using

visit Magnum MNS-6K Operator Training.

web-browser, at ftp://ftp.garrettcom.com/

GarrettCom’s MIBs for SNMP, visit

passwordm6kuser
userm6kuser

Magnum MNS-6K info.

hardware)

Page 16 of the GarrettCom 6KQE user manual — 2.4 Features and Benefits
Page 16 · click to enlarge
Page 16

provides for this with heavy-duty components. The ambient temperature dual-rating is

Magnum 6KQE Switches provide unicast non-blocking (all ports can run at full speed

Magnum 6KQE Managed Edge Switches are designed to naturally include fiber ports,

„ Vertical mounting for efficient convection cooling, no fans, extended temperature

Mounting brackets for vertical mounting are included. DIN-Rail mounting hardware

is optional. Ethernet signal and power cables attach at the bottom. Two sets of status

LEDs are included, one set viewable at the port connector and one set viewable from

extra security in their networks. MNS-6K-SECURE is an optional item--licensed per

at once) performance with standard Managed Network Software. They are typically

priority to priority tagged packets according to the IEEE 802.1p standard. For port-

and support mixes of multi-mode, single-mode, 100Mb and 1000Mb speed; full-and

half-duplex; classic Small Form Factor (SFF) and Small Form Pluggable (SFP) fiber

„ Relay Contacts for monitoring internal power and user-defined software events

signal loss of power internally. The other is software controlled and will signal user-

The 6KQE can be configured with the user’s choice of DC power supplies: 12V and

„ Heavy-duty design for Industrial Ethernet and extended temperature operation

Two Alarm Relay contacts monitor basic operations. One is for hardware, and will

24V for factory floor, 48V for tariffed carrier field facilities and for PoE-powered applications such as IP video surveillance, and 125V or 250V for substations. An

Magnum 6K-Series Switch, provides power and efficiency in a managed Ethernet

software product enables the versatile Magnum 6K Switches to perform efficiently

Magnum MNS-6K-SECURE software is designed for those customers demanding

The Magnum 6KQE switching hardware supports QoS, giving packet processing

defined software events such as a security violation or an S-Ring fault condition.

internal AC power supply may also be chosen, universal AC for use worldwide.

used in LAN traffic centers with up to 8 100Mb +2 Gigabit ports for backbone

and application-specific priorities of data, the QoS software may be configured.

connectors. RJ-45 10/100 ports can also be configured in the mix of port types.

in a wide range of managed LAN applications, including redundant topologies.

switch. All of the features in regular MNS-6K are included, plus extra security.

Fiber ports take more power than copper ports, but the Magnum 6KQE design

platform. A full range of industry-standard software functions in the MNS-6K

Managed Networks Software (MNS) basic version, combined with a

„ Switching services includes 802.1p QoS packet prioritization

„ Managed switching for high performance Ethernet LANs

„ All types of power input, 12, 24, 48, 125, 250VDC and AC

connections, where managed network services are desired.

60`C per UL methods, and 95°C per IEC type test methods.

„ MNS-6K-SECURE (optional, for extra security)

„ MNS-6K licensed Management Software

2.4 Features and Benefits

„ Fiber Ports Built-In

the front.

Page 17 of the GarrettCom 6KQE user manual — 2.5 Applications
Page 17 · click to enlarge
Page 17

„ S-Ring and Link Loss Learn for economical high availability using ring topology

S-Ring combined with the Link-Loss-Learn feature provides reliable fast recovery of a

may include Magnum switches and routers as well as other vendors industry-standard-

client/server computing, secure VLAN- performance upgrades to departmental networks,

media capability is ideal for integrating future-proof fiber cabling into the LAN structure.

fault in an economical ring topology combining unmanaged and managed switches.

RSTP-2004 provides reliable fast recovery from a fault in a redundant LAN, which

software. Magnum 6KQE Switches are easily used in a variety of applications including

performance characteristics of the 6KQE Switches enable them to inter-connect a series

The mixed-media modular capability is ideal for industrial applications where

RSTP products. Redundant topologies may include rings, dual-rings, and complex

availability. They provide the flexibility of 100Mbps fiber and copper ports as well as

connections may be via fiber or twisted pair cabling, 100Mbps or 10 Mbps speed, and

and stream traffic for VOIP and audio/video applications. They can also be used in a

much diversified combination of mixed media in Industrial floor applications. The

of subnets (one subnet per 6KQE Switch port) in a LAN traffic center. The subnet

existing Ethernet LAN network cabling must be accommodated. The fiber-built-in

Magnum 6KQE Edge Switches offer high performance, modularity and

single or dual Gigabit (1000Mb) ports, with industry-standard LAN management

„ RSTP-2004 for rings and meshes, fastest fault recovery, interoperability

GarrettCom 6KQE — 2.5 Applications diagram (page 17)
Fig. 5 · 2.5 Applications

2.5 Applications

full-or half-duplex.

meshes.

Page 18 of the GarrettCom 6KQE user manual — 2.5 Applications
Page 18 · click to enlarge
Page 18

computers for taking readings and data from Machines, Client/ Server databases, etc. and

reliably. The DIN-Rail Mounting options on the Magnum 6KQE allow the factory floor’s

GarrettCom 6KQE — 2.5 Applications diagram (page 18)
Fig. 6 · 2.5 Applications

The option of setting the ports at 10 or 100Mb on copper and 100Mb on fiber

easily connected together with the Fiber ports supported by the Magnum 6KQE Switch.

Equipped with lots of useful features including hardened enclosures, a wide

software features allow this Managed switch to provide a very secure highly available

operated features qualifies this managed switch to operate and perform securely and

sending these important data to the central office data warehouses) very securely and

advance network needs. The modularity of the 6KQE Managed Edge Switches make

organization’s multiple site offices and factory- floors. The different locations can be

spread of DC power supply options, and extended temperature ratings qualifies the

transportation system, or power utility application. The several MNS-6K software

reliably in all critical applications. The addition of S-Ring and the Link-Loss-Learn

The Managed 6KQE’s modularity along with the MNS-6K management

software features remarkably handle industrial environments (i.e. where the factory

floors are networked with Ethernet based mixed-media LANs equipped with PLCs,

A main NT-server in a secure area protected from earthquake or fire hazards can be

Fig 2.5a The industrial factory floor application with Magnum 6KQE

media provide widespread options to the users to mix and match their legacy and

Magnum 6KQE Managed switch for any Industrial factory-floor, traffic control,

industrial user to mount the 6KQE securely anywhere on their Network setup.

them an attractive choice for use in applications with LAN connections to an

Example 1Magnum 6KQE Switch for an Industrial Application

redundant network capability in any ring topology network.

connected to the full duplex Gigabit Fiber port.

Page 19 of the GarrettCom 6KQE user manual — 2.5 Applications
Page 19 · click to enlarge
Page 19

check the status of other Ethernet units. The entire spread network will be manageable to

GarrettCom 6KQE — 2.5 Applications diagram (page 19)
Fig. 7 · 2.5 Applications

The Magnum 6KQE Managed Edge Switch equipped with a mix of copper and

1000Mb. The user can utilize the SNMP feature equipped with VLAN, RMON, STP and

power failure can bring the whole thing down, a ring switch can be reconfigured and up

LAN segments supported by 100Mbps full-duplex future-proof fiber media to provide a

secure long distance LAN connection. The entire network is sharing a higher bandwidth

by providing copper/fiber media along with the higher bandwidth support of 10/100 and

above normal room temperatures occur while the network is in operation. Full-duplex

future proof fiber media can easily connect long distance subnets and provide a stable

secure network to all applications. The SNMP management capability of the Magnum

Example 2A managed network is needed to provide a redundant ring topology for

Gigabit-enabled data-mining server for the vital database located in a separate secured

user-configurable Magnum 6KQE provides an extra boost to the network requirements

networks and many other temperature sensitive critical Industrial applications where

6KQE Switch helps create a database of all the network subnets to easily manage the network.

maximum redundancy. In a network where any faulty cable, cable disconnection or

and running in milliseconds. The ring topology of the network consists of high speed

building. The copper ports are required for multiple subnets inside the power plant to

Fig 2.5b Magnum 6KQE equipped with S-Ring in redundant ring solution

fiber ports provides an economical and seamless solution to many requirements. The

Extended temperature ratings and a variety of options for AC/DC power

provide easy, detectable, uninterrupted support through a viewable SNMP monitor.

supplies qualify this managed 6KQE switch for use in non-temperature controlled

Page 20 of the GarrettCom 6KQE user manual — 2.5 Applications
Page 20 · click to enlarge
Page 20

breakup when set up in a ring topology. The Gigabit port option boosts the bandwidth for

to cover the wider area of video CCTV. The switch must be SNMP enabled and managed

the edge switch provides a very effective and economical solution for the video -vignette

compliant, 24VDC managed switch is required to meet the fiber and copper connections

the various features and modularity it has. Loaded with MNS-6K management software,

The security features (e.g. port-security, VLANs, SNMPv3, secure telnet, etc.)

10/100/1000Mb speeds easily meets the various speeds of legacy and future broadband requirements.

In a fast growing secure video environment, the 6KQE is a reliable and secure

copper/fiber options to meet requirements. The Gigabit uplink for storage or broadband

The 6KQE Managed Fiber with S-ring and Link-Loss-Learn features easily

fulfill the redundant requirement with a secure and fast reconfiguration time for cable

The Magnum managed edge switch easily qualifies for this requirement with

GarrettCom 6KQE — 2.5 Applications diagram (page 20)
Fig. 8 · 2.5 Applications

uplink allows the telecom user a very effective solution to store their sensitive data

Example 3In another application in an industrial environment, a 12 port Nebs

also boost the Magnum managed switches to provide a very effective and reliable

Fig 2.5c Magnum 6KQE deployed in a video security CCTV application for

other standard managed LAN features to provide a secure and stable network.

solution. The modular design of the Magnum 6KQE, provides a wide range of

solution. The modularity feature to support both copper and fiber at either

high speed to support the peak traffic and minimize congestion.

monitoring and securing the premises

to easily monitor the whole setup.

environment.

securely.

Page 21 of the GarrettCom 6KQE user manual — 3.1 Locating Magnum 6KQE Switches
Page 21 · click to enlarge
Page 21

3.0 INSTALLATION Before installing the equipment, it is necessary to take the

1.) If the equipment is mounted in an enclosed or multiple rack assembly, the steady-state long-term environmental temperature

2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate airflow must be maintained for proper and

3.) If the equipment is mounted in an enclosed or multiple rack system, placement of the equipment must not overload or load

4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent

This section describes installation of the Magnum 6KQE Switches, as well as connection

5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and

visually monitor the status LEDs. Keep an open area around the unit so that cooling can

silent when in operation. Internal electronics use the case as a heat sink, so the unit may

The rugged metal case of the Magnum 6KQE will normally protect it from

accidental damage in a lab or workplace setting. Maintain an open view of the front to

occur from convection while the unit is in operation. The 6KQE has no fans, so it is

around the equipment must be less than or equal to 600C.

For DC power input data, see Appendix B. For Dual Source, see Appendix C

overloading of the building/s electrical circuits.

For vertical panel mounting and wall mounting, see Section 3.3

3.1 Locating Magnum 6KQE Switches

For vertical DIN-Rail mounting, see Section 3.3.1

uncompromised earthing path.

following precautions:

unevenly the rack system.

of the various Ethernet media types.

normally be quite warm to the touch.

safe operation.

Page 22 of the GarrettCom 6KQE user manual — 3.2 Connecting Ethernet Media
Page 22 · click to enlarge
Page 22

See http://www.garrettcom.com/techsupport/power_budget.pdf for Power budget

media types100BASE-TX and 10BASE-T. CAT 5 cables should be used when making

The following procedure describes how to connect a 10BASE-T or 100BASE-TX

1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is

The various media types supported along with the corresponding IEEE 802.3,

The RJ-45 ports of the Magnum 6KQE can be connected to the following two

100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100

2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established.

Ethernet media types within a single Switch unit. This is accomplished by using a two

Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45

in order to provide flexibility in a mixed-speed network, since 10/100 copper

The Magnum 6KQE Switches are specifically designed to support standard

802.3D, 802.3u, 802.3AB and 802.3z standards and connector types are as follows:

Twisted Pair (CAT 5) 100BASE-TX RJ-45

Fiber (Multi-mode) 100BASE-FX MTRJ, LC

twisted pair segment to the RJ-45 port. The procedure is the same for both

Media IEEE Standard Connector

Fiber (Multi-mode) 1000BASE-SX LC (SFP)

Fiber (Multi-mode, Single-mode) 1000BASE-LX LC (SFP)

Fiber (Single-mode) 1000BASE-ZX LC (SFP)

popular Fiber Connectors which can be individually selected and configured.

shielded, either unshielded or shielded cables and wiring may be used.

Twisted pair (CAT5E or CAT6) 1000BASE-T RJ-45

3.2.1 Connecting Twisted Pair (CAT3, CAT5, UTP or STP)

Fiber (Single-mode) 100BASE-FX LC

switched ports are auto-sensing for either 10 and 100Mb/s.

calculations, to find fiber cable distance information.

unshielded and shielded twisted pair cables.

(See Section 5.1 for a description of the Modules)

3.2 Connecting Ethernet Media

meters (328 ft).

Page 23 of the GarrettCom 6KQE user manual — 3.2.2 Connecting Twisted Pair (CAT5e or better, UTP or STP)
Page 23 · click to enlarge
Page 23
1. 1000BASE-T connections require that all four pairs or wires be connected. Insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port.

(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx

advises that, for substation applications, the RJ-45 ports are intended for connectivity to

The RJ-45 Gigabit ports of the Magnum 6KQE can be connected to the media

The following procedure describes how to connect a 1000BASE-T twisted pair segment

2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established

connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable

recommended to use these ports in substation applications to interface to field devices

types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)

balanced cable is recommended to use when making 1000BASE-TX connections. In

either case, the max distance for unshielded twisted pair cabling is 100 meters (328 ft).

to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted

are the diameters of the core and the core plus the cladding respectively). Single-mode

fiber allows full bandwidth at longer distances, about 70km with the single-mode LC.

balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)

When using single-mode fiber cable, be sure to use single-mode fiber port

other communication equipment such as routers or telecommunication multiplexers

1613specifications for zero packet loss with fiber ports & with RJ-45 ports used as indicated here.

installed in close proximity (i.e., less than 2 meters or 6.5ft) to the 6KQE. It is not

across distances which could produce high (greater than 2500V ) levels of ground

potential rise (GPR) during line-to-ground fault conditions. The 6KQE passes the

3.2.2 Connecting Twisted Pair (CAT5e or better, UTP or STP)

3.2.3 Connecting Single-Mode Fiber Optic

cables and wiring may be used.

pair cables.

Page 24 of the GarrettCom 6KQE user manual — 3.2.5 Connecting Fiber Optic Cable to SFP Transceivers
Page 24 · click to enlarge
Page 24

The small form-factor pluggable (SFP) is a compact optical transceiver used in

applications. Due to its compact, hot pluggable characteristics, SFPs are becoming a very

All SFPs used in Magnum 6KQEs are compliant with the industry standard Multi-Source

removing the SFP transceiver for any reason. Not removing the fiber cable

first can damage the fiber cable, cable connector or optical interfaces. It is

1. Before connecting the fiber optic cable, remove the protective dust caps from

intervals; you must use the color-coded strand on the associated ports at each end of the

popular choice for various applications. The small-chassis Magnum 6KQE is designed

other device, it is recommended to use Crossover RJ-45 (4-twisted pair) category 5 or

2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens

advised not to remove and insert a SFP transceiver frequently as this may shorten its

connecting to any Server/workstation. While connecting with any Switch/repeater or

tissue dampened in alcohol. Make certain the connectors are clean before

the tips of the connectors on the PM. Save these dust caps for future use.

for industry-standard Gb-SFPs for user selection of the SFP gigabit media type as

Agreement (MSA) ensuring compatibility with a wide range of networking kit.

recommended to use a straight-through RJ-45(4-twisted pair) connection while

3.2.4 Gigabit SFP (Small Form-factor Pluggable) Transceivers

optical communications for both telecommunication and data communications

higher cabling. The maximum length supported on copper 1000BASE-T is

(see Section 1.2 for the SFP’s available for the 6KQE)

3.2.5 Connecting Fiber Optic Cable to SFP Transceivers

since the SFP modules are static sensitive devices.

connecting.

fiber optic segment.

100m (328 ft.).

useful life.

desired.

Page 25 of the GarrettCom 6KQE user manual — 3.3 Mounting Dimensions for 6KQE with metal brackets
Page 25 · click to enlarge
Page 25

If connected properly, you can check via (MNS-6K) software for verifying the validity of

For best cooling of the 6KQE, attach the metal brackets to metal (rather than wood

or plastic). Attaching to metal helps conduct heat away from the 6KQE through the

3. Find the Transmit (TX) and Receive (RX) markings on the SFP transceiver to
4. Position the SFP transceiver correctly before insertion, and then insert the SFP

transceiver carefully, until the transceiver connector snap into the place in the

5. Connect the Transmit (TX) port on the Magnum PM to the Receive (RX) port

polarity. Swap the fiber cables at the PM connector and also check the connectivity on

Each Mangum 6KQE is supplied with metal mounting brackets and screws to

vertically, as shown on following page, for proper cooling and long-life reliability. It is

panel or wall behind it, creating a rear space of about ¼ inch or 1cm. This allows

Since the 6KQE has special internal thermal techniques (patent pending) to move

the heat generated by the electronic components inside into the case, the case may

The LINK LED on the front of the PM will illuminate and turn Green, when a proper

connection has been established at both ends (and when power is ON in the unit). If

also advisable to mount the unit with space for air movement around the top and the

verify the top side of it. Some of the transceiver marks arrow sign for up.

mount the unit securely on a panel or wall. It is recommended to mount the 6KQE

LINK is not lit or OFF after cable connection, the normal cause is improper cable

of the remote device. Connect the Receive (RX) port on the PM to the

3.3 Mounting Dimensions for 6KQE with metal brackets

air circulation and cooling of the rear part of the case.

be quite warm to the touch during normal operation.

metal brackets and into the metal support structure.

Reconfigure or reboot both of the devices if required.

Transmit (TX) port of the remote device.

the target device to remedy this situation.

sides, typically a minimum of 1 inch.

socket connector.

SFP Gigabit ports.

Page 26 of the GarrettCom 6KQE user manual — 3.3.1 DIN-Rail Mounting the Magnum 6KQE
Page 26 · click to enlarge
Page 26
GarrettCom 6KQE — 3.3.1 DIN-Rail Mounting the Magnum 6KQE diagram (page 26)
Fig. 9 · 3.3.1 DIN-Rail Mounting the Magnum 6KQE

for the mounting screws into the supporting wall or panel is a rectangle 21.74 x 11.91 cm

vertically for proper convection cooling of the

be ordered as Model # DIN-RAIL-6KQ. See a

The DIN Rail bracket is mounted on

To install the 6KQE with the DIN-Rail

environment. It is available with an optional DIN-Rail bracket to mount it securely in a

6KQE viewed from the side, at the rear, with model DIN-RAIL-6KQ in place on the unit.

one of three available positions at the rear of

mounting purposes. The required four screws

The unit is mounted using the brackets as shown in the illustration above. The spacing

unit. The Magnum 6KQE requires one DIN-

Rail bracket for secure mounting. This may

provided on the rear of 6KQE for DIN-Rail

are included with the DIN-Rail bracket, and

bracket installed, hold the 6KQE in the side

metal factory floor enclosure, maintained

the 6KQE unit. Eight threaded holes are

The Magnum 6KQE is designed for use in a “factory floor” industrial

are no.4-40 X 5/16 PHIL. PAN Head.

3.3.1 DIN-Rail Mounting the Magnum 6KQE

GarrettCom 6KQE — 3.3.1 DIN-Rail Mounting the Magnum 6KQE diagram (page 26)
Fig. 10 · 3.3.1 DIN-Rail Mounting the Magnum 6KQE

(8.56 x 4.69 inches) center-to-center.

Page 27 of the GarrettCom 6KQE user manual — 3.4 Powering the Magnum 6KQE Managed Edge Switch
Page 27 · click to enlarge
Page 27

The DIN-Rail mounting bracket is optional and needs to be ordered as separate

consumption will range from about 15 up to 20 watts, depending on the port quantity and

holding position by moving the bottom of the 6KQE inwards to a vertical position. The

DIN-Rail bracket is heavy duty, and will hold the 6KQE securely in position, even with

To release the 6KQE from the DIN-Rail mounting, press the top of the DIN-Rail

vertical position with the bottom out, and with the top moved in toward the DIN-Rail.

The DC internal power supply supports installation environments where the

types in the configuration.. When connecting the Ethernet cabling, there is no need to

Power input options are available to suit the 6KQE Switches to special high-

bracket slide DOWN to release the 6KQE so that it can be dismounted by pulling the

bottom out. Once the bottom of the 6KQE is rotated out, the DIN-Rail bracket is not

Position the DIN bracket over the top of the DIN-Rail. Then, snap the bracket into

power down the unit. Individual cable segments can be connected or disconnected

availability communications and/or heavy industrial-grade applications, including:

engaged and the 6KQE can be moved up and out, free of the DIN-Rail mounting.

DC voltage is from 10 to 300 volts depending on the model selected. The power

* 12VDC, -48VDC, 24VDC, 125VDC and 250VDC with dual-source DC input * AC input with internal power supply (see Section 1.2, for Ordering Information)

* 12VDC, -48VDC, 24VDC, 125VDC and 250VDC with single DC input,

3.4 Powering the Magnum 6KQE Managed Edge Switch

without concern for power-related problems or damage to the unit.

items, e.g Model # DIN-RAIL-6KQ

cabling attached to the unit.

Page 28 of the GarrettCom 6KQE user manual — Traps
Page 28 · click to enlarge
Page 28

The Alarm Contacts feature, standard on Magnum 6KQE’s, provides two Form

close during normal software operation. A user-defined software malfunction, such as an

1. There are four terminal blocks (1,2,3,4) provided next to the DC power supply 2. The left two pins (1,2) are hardware operated 3. The right two pins (3,4) are software operated 4. These are both NC (normally closed) relays 5. The switch’s software operation needs to be enabled and set to get the Alarm traps. For detailed information about the Software Alarm and software control of SNMP alarm

When the Software Alarm is enabled, the Form C Normally Closed (NC) contact is held

The second NC Alarm Contact is held closed when there is power on the main

board inside of the Switch. This provides a “Hardware Alarm” because the NC contacts

The Alarm Contacts are on the front left area (next to the DC power source) of

monitoring wires at the green terminal block. When this option is present, the terminal

disable the Software Alarm feature with a software configuration command if desired.

SNMP Trap or a Software Security violation or an S-Ring Fault, causes the contact to

will open when internal power is lost, either from an external power down condition or

block for Alarm Contacts is part of the Power Input panel in the 6KQE case. The DC

“Software Alarm”, operated by user settings in the MNS-6K software. The user can

3.5 Alarm Contacts for monitoring internal power, and Software

The first NC Alarm Contact (top position, switch vertically mounted) is a

C Normally Closed (NC) contacts to which the user can attach two sets of status

Fig 3.5a Alarm Contacts:

(1,2) are hardware operated

(3,4) are software operated

the Magnum 6KQE unit and are green in color as shown in the picture.

traps, please reference the Magnum MNS-6K Software User Manual.

by the failure of the power supply inside of the Magnum Switch.

open and thus triggers an alarm in the user’s monitoring system

power input connection is in the same panel.

GarrettCom 6KQE — 3.5 Alarm Contacts for monitoring internal power, and Software diagram (page 28)
Fig. 11 · 3.5 Alarm Contacts for monitoring internal power, an…

Useful info. about Alarm contacts:

Traps

Page 29 of the GarrettCom 6KQE user manual — Pin Signal Description
Page 29 · click to enlarge
Page 29

Use a (DB-9) “null modem” cable to connect the Magnum 6KQE Console Port

The above provided information enables a managed station (a PC or Console terminal) to

(the RS-232 port on the 6KQE Switch) to your PC, so that your PC becomes

female to female cable is required to communicate properly. The Null-Modem (DB-9)

1 DCD Data Carrier detect (not used)

Magnum 6KQE Switch configuration for Network Management, please refer to

3.6.1 RS-232 (DB-9) Console port (Serial port) pin assignments

3 TXD Transmit Data (output)

cable is optional and can be ordered from the factory, along with the unit as-

3.6 Connecting the Console Terminal to Magnum 6KQE

2 RXD Receive Data (input)

Magnum 6K Software Manual available on GarrettCom‘s FTP site.

7 RTS Request to Send

5 GND Signal Ground

http://www.garrettcom.com/techsupport/sw_downloads.htm

8 CTS Clear to Send

Pin Signal Description

DB-9 (Console port connector)

4 open not used

6 open not used

9 open not used

connect directly to the switch using a straight through cable.

the 6KQE Console Terminal.

Also available on GCI website at:

CONSOLE CBL for serial port

CONSOLE USB for USB port

Page 30 of the GarrettCom 6KQE user manual — 4.0 OPERATION
Page 30 · click to enlarge
Page 30

intended for temporary connectivity to other equipment such as PCs. Since the

100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance. All ports can communicate to all other ports in a Magnum 6KQE,

configured through MNS software per unit as per the requirement. The internal functions

Each time a packet arrives on one of the switched ports, the decision is taken to

either filter or to forward the packet. Packets whose source and destination addresses are

on the same port segment will be filtered, constraining them to that one port and relieving

is on another port segment will be forwarded to the appropriate port, and will not be sent

interrupted operation of the network (such as occasional multi-cast packets) is forwarded

the rest of the network from having to process them. A packet whose destination address

mode, which eliminates bad packets and enables peak performance to be achieved when

removed or moved from one segment to another, the 6KQE Switch automatically keeps

An address-aging algorithm causes least-used addresses to fall out in favor for

advises that, for substation applications, the serial (DB-9) console ports are

console port connection is temporary, it is excluded from IEEE 1613 packet-

among all of its ports. The Magnum 6KQE supports10/100Mbs for copper media and

configuring necessary to be done for basic operation at installation or for maintenance.

All Magnum 6KQE units have address table capacities of 4K node addresses

The Magnum 6KQE units are plug-and-play devices. There is no software

(resides inside the unit) on the 6KQE4-RJ-45. There is an optional Half / Full duplex

A Magnum 6KQE provides switched connectivity at Ethernet wire-speed

but local traffic on a port will not consume any of the bandwidth on any other port.

The only hardware configuration settings are user options for an UP-LINK Switch

The Magnum 6KQE Switches operate in the store-and-forward switching

frequently-used addresses. To reset the address buffer, cycle power down-and-up.

This chapter describes the functions and operation of the Magnum 6KQE Switch.

suitable for use in larger networks. They are self-learning, so as nodes are added,

mode and 10Mbps or 100Mbps selection for the switched ports which must be

to the other ports where it is not needed. Traffic needed for maintaining the un-

loss testing per the 1613 standard-defined test procedure.

4.1 Switching Functionality

there is heavy traffic on the network.

of both are described below.

4.0 OPERATION

up with node locations.

to all ports.

Filtering and Forwarding · Address Learning

Page 31 of the GarrettCom 6KQE user manual — 4.1 Switching Functionality
Page 31 · click to enlarge
Page 31

copper ports is to connect one of them using a fiber media converter to another Switch in

desirable to operate the fiber link at 100Mb speed, and at either half- or full duplex mode

possible depending on what the other device supports. These are: (1) 100Mb full-duplex,

the device at the other end is not an auto-negotiating device, the 6KQE’s RJ-45 ports will

selection is made via MNS software. The factory default setting is for auto-negotiation.

At 10Mb or 100Mb-fixed speed, the user may select half- or full-duplex mode by MNS

require that the switched port to which they are connected be at the 100Mb fixed speed.

6KQE Switch’s RJ-45 ports handle this situation by configuring the ports as per desired through MNS software port settings and can check the port status of each port after the

When Magnum 6KQE RJ-45 copper ports are set for auto-negotiation and are

connected to another auto-negotiating device, there are 4 different speed and F/H modes

The auto-negotiation logic will attempt to operate in descending order and will normally

mode” result can change at any time depending on network changes that may occur). If

try to detect its idle signal to determine 10 or 100 speed, and will default to half-duplex

Software for each RJ-45 port separately. For detail information See Section 2.3 of this

arrive at the highest order mode that both devices can support at that time. (Since auto-

The RJ-45 ports independently support auto-cross (MDI or MDIX) in auto-

RJ-45 ports whether they support Auto-negotiation (e.g 10Mb Hub, media converter)

depending on the capabilities of the remote device. Standard commercially available

Fast Ethernet media converters mostly do not support auto-negotiation properly, and

Attachments to a 10/100 auto-negotiation port typically will not work properly. The

negotiation is potentially an externally controlled process, the original “highest order

Auto-negotiation per-port for 802.3u-compliant switches occurs when:

negotiation mode and will work properly with all the other connected devices with

The Managed 6KQE’s Fast Ethernet copper ports can be set for either fixed 100Mb

speed or for 10/100 F/H N-way auto-negotiation per the IEEE802.3u standard. The

One frequently-used application for the Managed Magnum 6KQE Switch

-- the devices at both ends of the cable are capable of operation at either

cross-over cable is required while using the 6KQE’s copper port to other devices.

4.2 Auto-Cross(MDIX) and Auto-negotiation, for RJ-45 ports

or fixed mode at 10Mb or 100Mb Half/Full Duplex(managed switch) or not. No

the network backbone, or to some other remote 100Mb device. In this case, it is

10Mb or 100Mb speed and/or in full- or half-duplex mode, and can

(2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex.

manual for information to access the “6K-MNS Software user guide”

send/receive auto-negotiation pulses, and . . .

Operation is according to the IEEE 802.3u standard.

at that speed per the IEEE standard.

change.

General information -

Page 32 of the GarrettCom 6KQE user manual — 4.3 Flow-control, IEEE 802.3x standard
Page 32 · click to enlarge
Page 32

that they are in is powered. These are exceptions to the “negotiate at LINK –

may be limited within that collision domain. The Path Delay Value (PDV) bit-times must

10Mb port is unable to keep up. It can also occur when multiple 100Mb ports are attempting to transmit to one 100Mb port, and in other protracted heavy traffic situations.

Magnum 6KQE Switches implement the 802.3x flow control (non-blocking) on

burst of activity causes the switch to save frames until its buffer memory is full. This is

Full-Duplex ports, which provides for a “PAUSE” packet to be transmitted to the sender

buffer queue increases, the Switch will send a “RESUME" packet to tell the transmitter

802.3x flow control standard in order to communicate properly during normal operation.

algorithm on 10/100 Mb ports for flow control. That is, the switch prevents frames from

receiving. This temporary “collision” delay allows the available buffer space to improve

  • NOTE – Some NIC cards only auto-negotiate when the computer system

When operating in 100Mb half-duplex mode, cable distances and hop-counts

account for all devices and cable lengths within that domain. For Magnum 6KQE Fast

sufficient time to let the Switch reduce the buffer space used. When the available free-

Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.

Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long

most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the

transmitting device is commanded to stop transmitting into the 6KQE Switch port for

to start sending the packets. Of course, the transmitting device must also support the

entering the device by forcing a collision indication on the half-duplex ports that are

Magnum 6KQE Switches incorporate a flow-control mechanism for Full-

-- the second of the two connected devices is powered up*, i.e., when

-- the LINK is re-established on a port after being lost temporarily.

when the packet buffer is nearly filled and there is danger of lost packets. The

enabled” rule above, but may be occasionally encountered.

4.3 Flow-control, IEEE 802.3x standard

as the switch catches up with the traffic flow.

LINK is established for a port, or

Page 33 of the GarrettCom 6KQE user manual — 5.0 Magnum 6KQE Managed Edge Switch Port Modules
Page 33 · click to enlarge
Page 33

4.4 Power Budget Calculations for 6KQE Modules with Fiber Media

See http://www.garrettcom.com/techsupport/power_budget.pdf for more information on

four ports (1,2,3 & 4) of the Magnum 6KQE Switches are fixed RJ-45 copper ports with

dual-speed 10/100Mbps auto-negotiating capability. Additionally the switch can accept

providing a wide selection of Ethernet copper and fiber media connections with 10, 100

6K products such as the 6K25e and 6K16V. For information about other

Receiver Sensitivity and Transmitter Power are the parameters necessary to

5.1 6KQE Modules An important feature of the Magnum 6KQE is the use of Port Modules for

flexible mixed-media connectivity to RJ-45 copper and various fiber media. The first

6K products, please see the applicable manual. For a list of 6KQE Port

compute the power budget. To calculate the power budget of different fiber media

where the “Cable Loss” for 62.5/125 and 50/125μm (M.m) is 2.8 dB/km,

Each 6KQE Port Module (PM) is individually described in the following sections.

up to two Port Modules to provide the user with up to 6 additional ports (10 total)

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km (ZX40)

This chapter describes each Port Module (PM), including appearance,

installations using Magnum products, the following equations should be used:

and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LX25)

and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (ZX70)

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

5.0 Magnum 6KQE Managed Edge Switch Port Modules

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

OPB (Optical Power Budget) = PT(min) - PR(min)

functionality, and status displays.

and 1000Mbps capability and up to 70km.

Modules, refer to Section 1.2

Power budget calculations

Page 34 of the GarrettCom 6KQE user manual — 5.1.1 6KQE Module LED designations
Page 34 · click to enlarge
Page 34

1= ON (Full Dx), OFF (Half Dx) 2= ON (Link) 3= BLINKING (Activity) 4= ON (1000Mb) Not used for Fiber 5= ON (100Mb) Not used for Fiber 6= ON (10Mb) Not used for Fiber

Gigabit (Copper / Fiber)

2= ON (Link), BLINKING (Link/Activity)

3= ON (Full Duplex), OFF (Half Duplex)

3= ON (Full Duplex), OFF (Half Duplex)

1= ON (100Mb), OFF (10Mb)

4= ON (PoE device detected)

5.1.1 6KQE Module LED designations

GarrettCom 6KQE — 5.1.1 6KQE Module LED designations diagram (page 34)
Fig. 12 · 5.1.1 6KQE Module LED designations
GarrettCom 6KQE — 5.1.1 6KQE Module LED designations diagram (page 34)
Fig. 13 · 5.1.1 6KQE Module LED designations
GarrettCom 6KQE — 5.1.1 6KQE Module LED designations diagram (page 34)
Fig. 14 · 5.1.1 6KQE Module LED designations

2= BLINKING (Activity) · 1= ON (Link) · LC (Fiber)

Page 35 of the GarrettCom 6KQE user manual — 5.1.3 6KQE4-RJ45, 4 x 10/100Mb RJ45 (Slot C)
Page 35 · click to enlarge
Page 35

independently N-way auto-negotiating and auto-crossover (MDIX) for operation at 10 or

100Mb speed in full- or half-duplex mode. (i.e., each independently selects a mode and speed to match the device at the other end of the twisted pair cable).

The 6KQE4-RJ45 4-port Copper module provides four 10/100Mb switched

RJ-45 ports. The 10/100Mb switched ports normally (as a default setting) are

5.1.3 6KQE4-RJ45, 4 x 10/100Mb RJ45 (Slot C)

5.1.2 6KQE Base Unit LED designations

GarrettCom 6KQE — 5.1.3 6KQE4-RJ45, 4 x 10/100Mb RJ45 (Slot C) diagram (page 35)
Fig. 15 · 5.1.3 6KQE4-RJ45, 4 x 10/100Mb RJ45 (Slot C)

6KQE Base Unit – Top label

Page 36 of the GarrettCom 6KQE user manual — 5.1.4 6KQE4-1MMRJ, 1 x MTRJ / 3 x RJ45 (Slot C)
Page 36 · click to enlarge
Page 36

indicates receiving Activity on that port when lit. The 10/100 LED indicates operation at

indicate the half-duplex mode. A twisted pair cable must be connected into an RJ-45 port

user may select 10Mb or 100Mb speed and full- or half-duplex mode per-port as per user

GarrettCom 6KQE — 5.1.4 6KQE4-1MMRJ, 1 x MTRJ / 3 x RJ45 (Slot C) diagram (page 36)
Fig. 16 · 5.1.4 6KQE4-1MMRJ, 1 x MTRJ / 3 x RJ45 (Slot C)

could produce high (greater than 2500V ) levels of ground potential rise (GPR)

indicates “ready for operation” on that port when lit. The blinking ACT (Activity) LED

device at the other end of the cable) in order for a LK LED to provide valid indications

user may disable auto-negotiation and fix the desired operation of each RJ-45 port. The

On the model 6KQE4-RJ45 module, there are four LEDs for each port, two

and the Link (LK) indicator for that port must be ON (indicating there is a powered-up

Using the 6K (MNS-6K or MNS-6K-SECURE) management software, the

telecommunication multiplexers installed in close proximity (i.e., less than 2

1613specifications for zero packet loss with fiber ports and with RJ-45 ports used as indicated here.

choice for 100Mbps “fiber-to-the-desktop” Ethernet connectivity. When installed in a

(for auto-negotiation and MDIX details, see Section 4.2 in the 6KQE User Guide).

100Mb speed when ON and at 10 Mb speed when OFF (when auto-negotiation is not disabled). The FDX/HDX LED is ON to indicate full-duplex operation and OFF to

substation applications to interface to field devices across distances which

Multimode connector. The MTRJ’s small size and ease of connection make it a good

Magnum 6KQE Series Switch, it supports fiber optic cable distances up to the IEEE-

advises that, for substation applications, the RJ-45 ports are intended for

meters or 6.5ft) to the 6KQE. It is not recommended to use these ports in

The 6KQE4-1MMRJ 4-port Fiber / Copper module provides one 100Mb

integrated into the connector, and two below the connector. The LK (Link) LED

The 6KQE4-1MMRJ fiber port is a Small Form Factor (SFF) MTRJ

requirements. (See Magnum MNS-6K Software Manual for additional info)

connectivity to other communication equipment such as routers or

Multimode MTRJ Fiber port and three 10/100Mb switched RJ-45 ports.

5.1.4 6KQE4-1MMRJ, 1 x MTRJ / 3 x RJ45 (Slot C)

of operating conditions on that port.

Page 37 of the GarrettCom 6KQE user manual — 5.1.5 6KQE4-2MMRJ, 2 x MTRJ / 2 x RJ45 (Slot C)
Page 37 · click to enlarge
Page 37

shielded twisted pair (STP) cable connections. When installed in a Magnum 6KQE Series

GarrettCom 6KQE — 5.1.5 6KQE4-2MMRJ, 2 x MTRJ / 2 x RJ45 (Slot C) diagram (page 37)
Fig. 17 · 5.1.5 6KQE4-2MMRJ, 2 x MTRJ / 2 x RJ45 (Slot C)

Multimode MTRJ Fiber ports and two 10/100Mb switched RJ-45 ports. (see also Section

GarrettCom 6KQE — 5.1.5 6KQE4-2MMRJ, 2 x MTRJ / 2 x RJ45 (Slot C) diagram (page 37)
Fig. 18 · 5.1.5 6KQE4-2MMRJ, 2 x MTRJ / 2 x RJ45 (Slot C)

Each port has an Activity (ACT) LED indicating packets being received and a

any standard length. It is equipped with a three-port RJ-45 connector, and offers 10/100

option occupies parts of Slot “A” and Slot “C”. (see also Section 5.1.4 for information)

The 6KQE4-1MMRJ copper ports support Ethernet twisted pair segments of

shielded to minimize emissions and will allow both unshielded twisted pair (UTP) and

Managed Switch, the copper ports support the standard distance of 100m on each port.

standard 100Mbps distance limits, i.e., typically 2km at full-duplex and 412m at half-

The 6KQE4-3MMRJ 4-port Fiber / Copper module provides three 100Mb

Link (LK) LED that indicates proper connectivity with the remote device when lit.

The 6KQE4-2MMRJ 4-port Fiber / Copper module provides two 100Mb

Multimode MTRJ Fiber ports and one 10/100Mb switched RJ-45 port. This module

full / half-duplex auto-negotiating capability on each port. The RJ-45 connector is

5.1.6 6KQE4-3MMRJ, 3 x MTRJ / 1 x RJ45 (Slot A, Slot C)

5.1.5 6KQE4-2MMRJ, 2 x MTRJ / 2 x RJ45 (Slot C)

5.1.4 for additional information)

duplex.

Page 38 of the GarrettCom 6KQE user manual — 5.1.7 6KQE4-1MLC, 1 x LC / 3 x RJ45 (Slot C)
Page 38 · click to enlarge
Page 38
GarrettCom 6KQE — 5.1.7 6KQE4-1MLC, 1 x LC / 3 x RJ45 (Slot C) diagram (page 38)
Fig. 19 · 5.1.7 6KQE4-1MLC, 1 x LC / 3 x RJ45 (Slot C)

The 6KQE4-1MLC copper ports support Ethernet twisted pair segments of any

standard length. It is equipped with a three-port RJ-45 connector, and offers 10/100 full /

half-duplex auto-negotiating capability on each port. The RJ-45 connector is shielded to

wiring closets while providing the advantage of “future-proof” fiber optic technology.

The cable end is a “plug-in” connector with both fiber strands terminated in

one housing that cannot be improperly inserted. Each port has an Activity (ACT) LED

indicating packets being received and a Link (LK) LED indicating proper connectivity

Managed Switch, the copper ports support the standard distance of 100m on each port.

The 6KQE4-1MLC fiber port is a Small Form Factor (SFF) LC Multimode

connector used primarily in 100Mbps fiber-to-the-desktop links. When installed in a

Magnum 6KQE Series Switch, it supports fiber optic cable distances up to the IEEE-

standard 100Mbps distance limits, i.e., typically 2km at full-duplex and 412m at half-

The compact size of the LC Connector reduces the size of wiring panels in

minimize emissions and will allow both unshielded twisted pair (UTP) and shielded

The 6KQE4-1MLC 4-port Fiber / Copper module provides one 100Mb

twisted pair (STP) cable connections. When installed in a Magnum 6KQE Series

Multimode LC Fiber port and three 10/100Mb switched RJ-45 ports.

5.1.7 6KQE4-1MLC, 1 x LC / 3 x RJ45 (Slot C)

with the remote device when lit.

duplex.

Page 39 of the GarrettCom 6KQE user manual — 5.1.8 6KQE4-2MLC, 2 x LC / 2 x RJ45 (Slot C)
Page 39 · click to enlarge
Page 39
GarrettCom 6KQE — 5.1.10 6KQE4-xSLC, LC Singlemode (20km) / RJ45 Module diagram (page 39)
Fig. 20 · 5.1.10 6KQE4-xSLC, LC Singlemode (20km) / RJ45 Modul…
GarrettCom 6KQE — 5.1.10 6KQE4-xSLC, LC Singlemode (20km) / RJ45 Module diagram (page 39)
Fig. 21 · 5.1.10 6KQE4-xSLC, LC Singlemode (20km) / RJ45 Modul…

These modules provide the same functions as the Multimode versions (see Sections 5.1.7

These modules provide the same functions as the Multimode versions (see Sections 5.1.7

Multimode LC Fiber ports and one 10/100Mb switched RJ-45 ports. This module option

The 6KQE4-xSLC 4-port Fiber / Copper modules provide 100Mb Singlemode

The 6KQF-xSLCL 4-port Fiber / Copper modules provide 100Mb Singlemode

LC Fiber ports, supporting distances up to 20km , and 10/100Mb switched RJ45 ports.

LC Fiber ports, supporting distances up to 40km , and 10/100Mb switched RJ45 ports.

The 6KQE4-3MLC 4-port Fiber / Copper module provides three 100Mb

The 6KQE4-2MLC 4-port Fiber / Copper module provides two 100Mb

occupies parts of Slot “A” and Slot “C”. (see Section 5.1.7 for more information)

5.1.10 6KQE4-xSLC, LC Singlemode (20km) / RJ45 Module

5.1.11 6KQF-xSLCL, LC Singlemode (40km) / RJ45 Module

Multimode LC Fiber ports and two 10/100Mb switched RJ-45 ports.

5.1.9 6KQE4-3MLC, 3 x LC / 1 x RJ45 (Slot A, Slot C)

5.1.8 6KQE4-2MLC, 2 x LC / 2 x RJ45 (Slot C)

thru 5.1.9 for more detail and panel configurations).

thru 5.1.9 for more detail and panel configurations).

(see Section 5.1.7 for more information)

Page 40 of the GarrettCom 6KQE user manual — 5.1.13 6KQE-2GSFP, 1GSFP (Gigabit SFP Fiber ports) (Slot D)
Page 40 · click to enlarge
Page 40
GarrettCom 6KQE — 5.1.12 6KQE-2GCU, 1GCU (Gigabit RJ45 Copper ports) (Slot D) diagram (page 40)
Fig. 22 · 5.1.12 6KQE-2GCU, 1GCU (Gigabit RJ45 Copper ports) (…
GarrettCom 6KQE — 5.1.12 6KQE-2GCU, 1GCU (Gigabit RJ45 Copper ports) (Slot D) diagram (page 40)
Fig. 23 · 5.1.12 6KQE-2GCU, 1GCU (Gigabit RJ45 Copper ports) (…

There are six LEDs provided for each Gigabit port. Each Copper Gigabit port

10/100/1000Mb RJ-45 ports. The Magnum 6KQE offers a Gigabit option with multiple choices of Copper

10/100/1000Mbps or Gigabit SFP Fiber transceivers for the modular slot. Up to two Gigabit ports (maximum) can be configured in Slot D only.

transceiver locations that can operate at 10/100/1000Mbps speeds. Transceivers are

The 6KQE-2GSFP 2-port Fiber Gigabit module provides two SFP open

has LEDs that indicate FH (Full or Half Duplex), LK (Link), ACT (Activity) and

5.1.12 6KQE-2GCU, 1GCU (Gigabit RJ45 Copper ports) (Slot D)

The 6KQE-2GCU 2-port Copper Gigabit module provides two fixed

The 6KQE-1GCU 1-port Copper Gigabit module provides one fixed

5.1.13 6KQE-2GSFP, 1GSFP (Gigabit SFP Fiber ports) (Slot D)

10/100/1000Mbps speed (set to AUTO by default).

10/100/1000Mb RJ-45 port.

Page 41 of the GarrettCom 6KQE user manual — 5.2 6KQEP-48VDC, Base Unit w/PoE Power-pass-through
Page 41 · click to enlarge
Page 41

LEDs are configured the same as the copper gigabit option. (see Section 5.1.12

GarrettCom 6KQE — 5.2 6KQEP-48VDC, Base Unit w/PoE Power-pass-through diagram (page 41)
Fig. 24 · 5.2 6KQEP-48VDC, Base Unit w/PoE Power-pass-through

except they have the capability of providing power on each port to power up attached PD

properly to an IEEE 803.af compliant PD device on that port. When non-PoE devices are

devices. The PoE LED is ON when the attached PD is drawing power from the

The 6KQE is available with the option of having PoE capabilities on the four

The PoE (Power-over-Ethernet) RJ-45 ports are similar to regular RJ-45 ports,

PoE. LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that

port. The power is supplied on the data pairs, per IEEE802.3af PoE standard.

strong enough to provide power to the 6K switch and to all 4-RJ-45 ports with

available with both multi-mode 850nm (550m), 1310nm (3km), single-mode 1310nm

  • For non-PoE devices connected, the PoE port will act as a normal RJ-45 port

(10/100) ports. Each port supplies up to 15watts to power attached PoE PD devices.

The LEDs on the PoE ports are slightly different compared to regular (non-

PoE) RJ-45 ports. When the PoE port is in use, the PoE LED is ON when connected

connected, the PoE LED is OFF. Operation of Ethernet data traffic is not affected by

through, so the 48VDC power input source to the Magnum 6KQE must be

The 1000Mb Gigabit SFP fiber-port modules on the Magnum 6KQE are

normally set (factory default) to operate at AUTO mode for best fiber distance and

The 6KQE-1GSFP 1-port Fiber Gigabit module provides one SFP open

devices, per the IEEE802.3af PoE standard. The power-pass-through PoE ports are

dependent upon the -48VDC input power to supply the PD power for these RJ-45

  • For PoE devices, each RJ-45 PoE port supports only 802.3af complaint
  • The PoE ports in Magnum 6K’s with 48VDC power input act as a pass-

(10km and 25km) and single-mode 1550nm (40km and 70km) fiber options.

5.2 6KQEP-48VDC, Base Unit w/PoE Power-pass-through

and the PoE LED is OFF. No power is sent out from the port.

transceiver location that can operate at 10/100/1000Mbps speeds.

PD devices connected (up to 15 watts per PoE port).

fixed RJ45 ports in the base unit (ports 1, 2, 3 and 4).

(see page 5 of this manual for part numbers)

is marked as LINK/ACT.

performance.

PoE LEDs Summary · above)

Page 42 of the GarrettCom 6KQE user manual — 6.1 Before Calling for Assistance
Page 42 · click to enlarge
Page 42

port pins and no power is coming to the PoE ports for some reason, all the PoE

suggestions listed below prior to contacting your supplier. However, if you are unsure of

known good device. Verify whether or not the problem is corrected. If not, go

to Step 5 below. If the problem is corrected, the Magnum 6KQE Switch and its

intended to help locate, identify and correct these types of problems. Please follow the

1. If difficulty is encountered when installing or operating the unit, refer back to
3. Make sure that DC power is properly attached to each Magnum 6KQE Switch

Switch product, it is recommended that the problem device be replaced with a

5. If the problem continues after completing Step 4 above, contact your supplier

of the Magnum 6KQE Switch unit or if unknown, contact GarrettCom, Inc. by

  • In the case where the 48VDC power in not internally connected to the POE

port LEDs are ON simultaneously to indicate a trouble condition. The ports

performing as expected, do not attempt to repair the unit; instead contact your supplier

the Installation Section of the applicable chapter of this manual. Also check

4. If the problem is isolated to a network device other than the Magnum 6KQE

d. Any particular application that, when used, appears to create the problem;

to make sure that the various components of the network are interoperable.

consistently high performance in all network environments. The installation of a

Should problems develop during installation or operation, this section is

2. Check the cables and connectors to ensure that they have been properly

impaired during installation. (About 90% of network downtime can be

1. A complete description of the problem, including the following points:

All Magnum Ethernet products are designed to provide reliability and

connected and the cables/wires have not been crimped or in some way

Magnum 6KQE Switch is a straight forward procedure. The operation is also

the procedures described in this section or if the Magnum 6KQE Switch is not

unit. Use the PWR LEDs to verify each unit is receiving power.

straightforward and is discussed in Section 4.0 of this 6KQE User Guide.

fax, phone or email (support@garrettcom.com) for assistance.

will still operate properly for data traffic to non-PoE devices.

Please be prepared to provide the following information.

for assistance or contact GarrettCom Customer Support.

attributed to wiring and connector problems.)

c. The components involved in the problem;

associated cables are functioning properly.

a. The nature and duration of the problem;

b. Situations when the problem occurs;

6.1 Before Calling for Assistance

6.2 When Calling for Assistance

6.0 TROUBLESHOOTING

Page 43 of the GarrettCom 6KQE user manual — 6.1 Before Calling for Assistance
Page 43 · click to enlarge
Page 43

All returns for repair must be accompanied by a Return Material Authorization

4. A record of changes that have been made to your network configuration prior
3. It is useful to include other network equipment models and related hardware,

including personal computers, workstations, terminals and printers; plus, the

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

GarrettCom will carefully test and evaluate all returned products, will repair products

number(s). Include the date(s) that you purchased the products from your

to the occurrence of the problem. Any changes to system administration

that are under warranty at no charge, and will return the warranty-repaired units to

the sender with shipping charges prepaid (see Warranty Information, Appendix A,

units under warranty. Testing and repair of product that is not under warranty will

GarrettCom reserves the right to charge for the testing of non-defective

2. An accurate list of GarrettCom product model(s) involved, with serial

for complete details). However, if the problem or condition causing the return

Failure symptoms, including a full description of the problem.

6.3 Return Material Authorization (RMA) Procedure

(RMA) number. To obtain an RMA number, please use this URL -

cannot be duplicated by GarrettCom, the unit will be returned as:

Name and phone number of your contact person.

Please have the following information readily available:

Packing List Number (or Sales Order Number)

procedures should all be noted in this record.

various network media types being used.

No Problem Found.

Name of your company / institution

Serial Number (or Invoice Number)

result in a customer (user) charge.

supplier.

Your shipping address · Date of installation · Product name

Page 44 of the GarrettCom 6KQE user manual — APPENDIX A: WARRANTY INFORMATION
Page 44 · click to enlarge
Page 44

sheet or bag for shipping protection. ( You may retain all connectors and this

1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic

material. This material may cause electro-static shock damage to the unit.

CAUTION : Do not pack the unit in Styrofoam "popcorn" type packing

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

GarrettCom, Inc. warrants its products to be free from defects in materials

replace components in the products that prove to be defective at no charge other

product has been damaged by misuse, misapplication, or as a result of service or

This warranty will not be effective if, in the opinion of GarrettCom, the

and workmanship for a period of three (3) years from the date of shipment by

than shipping and handling, provided that the product is returned pre-paid to

inspecting any product returned for warranty repair which turns out not to be

3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to:

During this warranty period, GarrettCom will repair or, at its option,

GarrettCom reserves the right to make a charge for handling and

Should you need to ship the unit back to GarrettCom,

APPENDIX A: WARRANTY INFORMATION

6.4 Shipping and Packaging Information

47823 Westinghouse Dr.

Attn.: Customer Service

modification other than by GarrettCom.

please follow these instructions:

GarrettCom, Inc.

Installation Guide.)

GarrettCom.

GarrettCom.

faulty.

Fremont, CA 94539

Page 45 of the GarrettCom 6KQE user manual — APPENDIX B : DC Power Input
Page 45 · click to enlarge
Page 45

24, 48, 125 and 250VDC nominal. The wide range of DC power input types qualifies this product for use in 12, 24, 48, 125 and 250VDC applications in different industries.

inputs. It protects the Switch from incorrect DC input connections. An incorrect polarity

Each Magnum Model 6KQE Managed Switch requires DC power input, at 12,

DC Power Terminals“+”, “ - ” are internally floating so that user may ground either

allows the Switch to operate only whenever DC power is correctly applied to the two

B2.0 12, 24, –48, 125 and 250VDC POWER, THEORY OF OPERATION

GarrettCom 6KQE — APPENDIX B : DC Power Input diagram (page 45)
Fig. 25 · APPENDIX B : DC Power Input

See also Section 1.0, Technical Specifications, for the 6KQE base unit

12VDC Power Input nominal (range 8 to 18VDC)

B1.0 Specifications for Magnum 6KQE Switches, DC Power at 12, 24,

20 watts typical (for a fully loaded fiber model with 2Gb) 15 watts typical (for 8 ports, copper and 100Mb fiber)

Standard 6KQE DC Power Input Terminal Block: “ -, GND, + ”

125VDC Power Input nominal (range 88 to 150VDC) 250VDC Power Input nominal (range 160 to 300VDC)

24VDC Power Input nominal (range 18 to 36VDC) -48VDC Power Input nominal (range 36 to 60VDC)

GNDground wire connection to the 6KQE chassis screw

–48, 125 and 250VDC Power input

APPENDIX B : DC Power Input

Fig B1.0 Location of chassis ground

power from an external source can

125 and 250VDC power options are designed using diodes inside

connection terminals, so that the

The 12, 24, -48VDC,

behind the two external power

on each DC power input line

only flow into the hub. This

Power Consumption:

Page 46 of the GarrettCom 6KQE user manual — B3.0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHES
Page 46 · click to enlarge
Page 46

connection, for example, will neither affect the Switch, its internal power supply, nor will

B3.0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHES

Magnum 6KQE Switches are easily installed in a variety of applications where

The –48VDC solution is particularly useful in the telecommunication industry,

other communication companies. In addition, many high availability equipment services,

facilities often use a battery backup system to maintain operations in the event of a power

identified as positive (+) and negative (-), and they are electrically floating inside the unit

The connection procedure is straightforward. Simply insert the DC leads to the

(GND) connects to the Switch chassis screw provided under the DC terminal. Ensure that

12, 24, -48VDC, 125 and 250VDC power is used as the primary power source. The DC power configuration capability provides an Ethernet networking solution utilizing a

where it is common for facilities to operate on -48VDC power. Such companies include

environment, where it is common for facilities to operate on 24VDC or 125VDC power.

industrial automation such as factory floor, process plants, HVAC, military equipment,

250VDC leads to the DC power terminal block on the Magnum 6KQE Switch. The DC terminal block on the Magnum 6KQE Managed Switch is located on the left front of the

and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead

regular and wireless telephone service providers, Internet Service Providers (ISPs) and

The 125VDC options are mainly used in power utilities, such as electrical substations,

so that either may be grounded by the user if desired. The chassis is “earth” or ground

electrical generating plants, etc. The 24VDC applications are mainly in heavy duty

unit and is equipped with four (4) screw-down lead posts. The power terminals are

Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground

will connect to the post labeled “+ve” and the rest to the “-ve”. The GND can be

such as broadcasters, publishers, newspaper operations, brokerage firms and other

This section describes the proper connection of the 12, 24, –48, 125 and

failure. It is also frequently used for computer system backup, management and

The 24V and 125VDC options are particularly useful in the industrial

B4.0 6KQE, 12, 24, –48, 125 and 250VDC INSTALLATION

special power supply in switches with a proven track record.

it blow the fuse in the internal power supply.

operations monitoring equipment.

each lead is securely tightened.

hooked up at the last

(GND).

etc.

Page 47 of the GarrettCom 6KQE user manual — B5.0 OPERATION
Page 47 · click to enlarge
Page 47

12VDC, 24VDC, 125VD or 250VDC products, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more

1. Minimum 14AWG cable for connection to an earth wiring. 2. Use only with Listed 10A circuit breaker provided in building installation. 3. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.
4. Fastening torque of the lugs on the terminal block: 9 inch-pound max. 5. To secure a centralized DC Power Source cable , use at least four cable ties to

24VDC, 125VDC or 250VDC dual-source power input is identical to that of the standard single-source DC-powered models.

disconnect device in the building installation supply circuit to the product.

secure the cable to the rack at least 4 inches apart, with the first one located

Operation of Magnum 6KQE Switches with the optional -48VDC, 12VDC,

CAUTION: 48VDC products shall be installed with a readily accessible

Before connecting live power lines to the Terminal Block of –48VDC,

“+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be

the user may elect to Ground either + or - terminal to suit the customer’s use.

Minimum 18AWG cable for connection to a Centralized DC power source.

When power is applied, the green PWR LED will illuminate.

Please refer to Section 6.0 for troubleshooting

B4.1 UL Requirements for DC-powered units

within 6 inches of the terminal block.

B6.0 TROUBLESHOOTING

connected to the post labeled “+”.

B5.0 OPERATION

Page 48 of the GarrettCom 6KQE user manual — C1.0 SPECIFICATIONS - FOR MAGNUM 6KQE EDGE SWITCH
Page 48 · click to enlarge
Page 48

12VDC, 24VDC, 125VDC and 250VDC models with this Dual-Source option are identical to those listed in the Magnum 6KQE Edge Switches Installation and User Guide,

125VDC and 250VDC Dual-Source power supply are designed for installations where a battery plant is the power source, and where two separate power sources are utilized in

DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”

The functionality of the Magnum 6KQE Switch -48VDC, 12VDC, 24VDC,

With the exception of the dual DC input power connections and the power

supply, all specifications and configuration options for the Magnum 6KQE -48VDC,

125VDC and 250VDC Dual-Source Option units are identical to the AC-powered models. Refer to the main sections of this Installation and User Guide for a detailed

Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-125V)

Power Supply (Internal, 250VDC Dual-Source, model # Dual-Src-250V)

The 6KQE-Switch models with the internal -48VDC, 12VDC, 24VDC,

Power Supply (Internal, 12VDC Dual-Source, model # Dual-Src-12V)

Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)

C1.0 SPECIFICATIONS - FOR MAGNUM 6KQE EDGE SWITCH

APPENDIX C: Internal DC Dual-Source Power Input Option

GNDground wire connection to the hub chassis screw
GNDground wire connection to the hub chassis screw
GNDground wire connection to the hub chassis screw
GNDground wire connection to the hub chassis screw
GNDground wire connection to the hub chassis screw
InputTwo separate sources, each at 160 - 300 VDC
InputTwo separate sources, each at 36 - 60 VDC
InputTwo separate sources, each at 18 - 36 VDC
InputTwo separate sources, each at 88 - 150 VDC

order to increase operational uptime and to simplify maintenance.

InputTwo separate sources, each at 8-18 VDC

C2.0 MAGNUM 6KQE, with DC Dual-Source option

including Appendix B “Internal DC Power Supply Option”

Power Supply (Internal, -48VDC Dual-Source)

description of the Magnum 6KQE Switches.

Page 49 of the GarrettCom 6KQE user manual — C5.0 INSTALLATION
Page 49 · click to enlarge
Page 49

b) The Switch unit will not allow power to flow from a higher voltage input to a lower

c) When one correct DC input is present, the Switch will receive power if the other DC

even if one input connection is reversed while the Switch is operating from the other

This section describes the proper connection of the -48VDC, 12VDC, 24VDC,

d) Reverse polarity connections, if they should accidentally occur on either input, will

not damage the Switch or power supply internally (nor will it blow the fuse in the

internal power supply) because of the blocking action of the diodes. This is true

125VDC and 250VDC dual source leads to the power terminal block on the Magnum 6KQE Switch (shown in Figure above)

chassis on each DC power input line. A diode is placed in each of the four input lines

a) The Switch unit can receive power from either input, “A” or “B”. The hub will

normally draw its power from the DC source with the highest voltage at a given

voltage input, i.e. the two DC power sources are not mixed together by the hub.

The Dual-Source DC power option is designed using diodes inside of the

Figure C5.0DC Dual-Source, wiring

connections with Dual-Source option.

C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN

e) The Switch will not receive power (and will not work) when both inputs are

Dual Source Terminal block

input is absent, or even if it is connected with reverse polarity or shorted or

C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION

simultaneously absent or are both incorrectly connected.

GarrettCom 6KQE — C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION diagram (page 49)
Fig. 26

power from an external source can

applied to either or both of the two

whenever DC power is correctly

(behind the four external power

connection terminals) so that

C5.0 INSTALLATION

only flow into the unit. This

allows the unit to operate

grounded.

source.

time.

inputs.

Page 50 of the GarrettCom 6KQE user manual — C6.0 ORDERING INFORMATION FOR DUAL SOURCE POWER
Page 50 · click to enlarge
Page 50

chassis is earth/ground (GND). The Dual Source terminal block for the 12, 24, 48, 125

“+ve” voltage lead from a +ve or –ve power supply must be connected to the

The connection procedure is straightforward. Simply connect the DC leads to

To order the optional Dual-Source power supply factory installed, add “Dual-

negative (A-), and the secondary power terminals as negative (B-), positive (B+). The

customer’s use. Before connecting live power lines to the terminal block,

the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground

(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely

The terminal block is located on the left front of the unit next to the Alarm

ground, so the user may elect to Ground either + or - terminal to suit the

always use a digital voltmeter to measure the output voltage of the power

supply and determine the lead which is more “+ve potential”. The more

terminal block and is equipped with four (4) screw-down lead posts. The primary

C6.0 ORDERING INFORMATION FOR DUAL SOURCE POWER

Src-xxxV” as a separate line item following the product model.

http://www.garrettcom.com/techsupport/insertion_guides/6kqecg.pdf

See the Configuration Guide on the GCI web site at

ExampleMagnum 6KQE-48VDC

terminals are identified as positive (A+),

for additional information.

post labeled “+”.

and 250VDC are the same.

tightened.

Dual-Src-48V

Ask about the GarrettCom 6KQE

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom 6KQE

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom 6KQE manual PDF

50 pages·584 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…