

Installation and User Guide

Hardware

Copyright © 2009 GarrettCom, Inc. All rights reserved. No part of this publication may be
serviceable parts. Attempted service by unauthorized personnel shall render all
GarrettCom, Inc. reserves the right to change specifications, performance characteristics
Please use the mailing address, phone and fax numbers and email address listed below:
warranties null and void. If problems are experienced with Magnum 6KQE
GarrettCom is a registered trademark and Magnum, Dymec, DynaStar, Personal
Switch, Link-Loss-Learn, S-Ring, Convenient Switch and Converter Switch
reproduced without prior written permission from GarrettCom, Inc.
Managed Edge Switch
Switch products, consult Section 6, Trouble Shooting.
47823 Westinghouse Dr. Fremont, CA 94539-7437
GarrettCom, Inc.
UL is a registered trademark of Underwriters Laboratories
NEBS is a trademark of Telcordia Technologies
Ethernet is a trademark of Xerox Corporation
Printed in the United States of America
and/or model offerings without notice.
are trademarks of GarrettCom, Inc.
Fax (510) 438-9072 · Contacting GarrettCom, Inc · Trademarks

This equipment generates uses and can radiate frequency energy and if not
installed and used properly in strict accordance with the manufacturer's instructions, may
cause interference to radio communication. It has been tested and found to comply with the
limits for a Class A computing device in accordance with the specifications in Subpart J of
Part 15 of FCC rules, which are designed to provide reasonable protection against such
interference when operated in a commercial environment. Operation of this equipment in a
residential area is likely to cause interference, in which case the user, at their own expense,
will be required to take whatever measures may be required to correct the interference.
which has suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable
Cet appareil respecte toutes les exigences du Réglement sur le matériel du
ONLY be replaced by GarrettCom personnel through the RMA process.
power unit, marked Class 2, or listed ITE Power Supply, marked LPS,
This Class A digital apparatus meets all requirements of the Canadian
(Dedicated Equipment Rooms, Electrical Closets, or the like).
circuit breaker in the supply circuit when connected to a 48V
Radio Frequency Interference Statement
Interference-Causing Equipment Regulations.
Canada. Cet appareil est Classe A.
Electrical Safety requirements:
rated output current.
centralized source.
Federal Communications Commission · Canadian Emissions Statement



5.1.11 6KQF-xSLCL, LC Singlemode (40km) / RJ45 Module 34 5.1.12 6KQE-2GCU, 1GCU (Gigabit RJ45 Copper ports) (Slot D) 35 5.1.13 6KQE-2GSFP, 1GSFP (Gigabit SFP Fiber ports) (Slot D) 35 5.2 6KQEP-48VDC, Base Unit w/PoE Power-pass-through 36
6.1 Before Calling for Assistance 37
6.2 When Calling for Assistance 37
6.3 Return Material Authorization (RMA) Procedure 38
6.4 Shipping and Packaging Information 39
Revisions:

100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft)
Unshielded twisted pair - 100 m (328 ft)
10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)
10BASE-FL single-mode fiber optic - 10 km (32,810 ft)
10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)
100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft)
100BASE-FX, full-duplex, single-mode - 20.0 km (66K ft)
100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft)
100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)
1000BASE-T (CAT5e or higher is recommended) - 100m (328 ft) 1000BASE-SX, full-duplex, multi-mode (62.5μm cable) - 220m
Shielded twisted pair - 150 m (492 ft)
Shielded twisted pair - 150 m (492 ft)
15 μs + packet time (10 to 10 Mbps, and 10 to 100Mbps)
Throughput with 8 10/100 and 2Glink max.- 4.17M pps (Transmit)
Maximum Standard Gigabit Ethernet Segment Lengths:
Maximum Standard Fast Ethernet Segment Lengths:
Network Standards and Compliance, hardware
Maximum 10 Mbps Ethernet Segment Lengths
duplex flow -control, non-blocking
Back plane- 2.66Gb/s per slot
Filtering / Forwarding Rate:
1.0 SPECIFICATIONS
Performance

-40° to 140° F (-40° to 60°C) for UL60950 and Component Parts rating
-40° to 195° F (-40° to 85°C) for IEC 60068 Type Test short term rating
used as a sink, designed for vertical mounting, no fans
1000BASE-SX, full-duplex, multi-mode (50μm cable) - 550m 1000BASE-LX, full-duplex, multi-mode (50, 62.5μm cable) - 550m 1000BASE-LX, full-duplex, single-mode (9μm cable) - 5km 1000BASE-ZX, full duplex, single-mode (9μm cable) - >70km Fiber Multi-mode connector types supported:
LEDs: Per Port (one set at the port, one set on swivel top on right side)
12VDC Power Input nominal (range 8 to 18VDC)
Conformal Coating (humidity protection) optional: Request quote
One NC indicating internal power, one NC software controllable
Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX
(see section 5.1.1 and 5.1.2 for detailed LED configurations)
125VDC Power Input nominal (range 88 to 150VDC) 250VDC Power Input nominal (range 160 to 300VDC) Std. Terminal Block : “ -, GND, + ”
24VDC Power Input nominal (range 18 to 36VDC) -48VDC Power Input nominal (range 36 to 60VDC)
17.4 cm H x 19.1 cm W x 5.08 cm D
DC Power Supply (Internal, floating ground design)
Fiber Port, 1000BASE-SX, SFP modules
Fiber Port, 1000BASE-LX, SFP modules
Serial DB-9, see details at sec. 3.6
Fiber Single-mode connector types:
Ambient Temperature:

A Dual-Source option is available for the 12VDC, 24VDC, –48VDC, and 125VDC
and 250VDC models. This provides for continuity of operation when either of the
IEEE 1613 Class 2 Environmental Standard for Electric Power Substations
See also Note for Power Substations in Section 3.2.1, 3.6.1, and 5.1.3
IEC 61850 EMC and Operating Conditions Class C for Power Substations
NEMA TS-2 and TEES for DC-powered and PoE-powered traffic control
Vertical mounting normal. Suitable for wall or DIN-Rail mounting (6KQE)
UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class A
http://www.garrettcom.com/techsupport/insertion_guides/6kqecg.pdf
Class1 Division 2 and ATEX for hazardous locations, pending
The Dual-Source Terminal Block is marked : “ +A, -A, -B, +B ”
20 watts Max. (for a fully loaded fiber model with 2Gb) 15 watts Max. (for 8 port copper and 100Mb fiber model)
Email info@GarrettCom.com for additional information.
100-240VAC Power Input, 47 to 63 Hz (auto-ranging)
DC input sources is interrupted. See Appendices B and C.
See the Configuration Guide on the GCI web site at
Agency Approvals and Standards Compliance:
NEBS Level 3 and ETSI Compliant
Dual DC Power Input (Optional)
for configurations and options..
AC Power Supply (Internal)
Power Consumption:
6KQE Mounting:
equipment

10/100 copper ports. Up to 3 100Mb fiber ports or up to four more 10/100 copper ports (or combinations) may also be configured, and up to 2 Gb ports are optional.
Please use this URL: for the complete Configuration Guide for the Magnum 6KQE.
(Slot C is 10/100 RJ-45 or 100Mb Fiber only)
For licensed managed networks software (MNS-6K, RS-Ring and S-Ring) including
6KQE4-1SLC adds three 10/100 copper and one SM 20Km 100Mb LC fiber ports
6KQE4-3SLC adds one 10/100 copper and three SM 20Km 100Mb LC fiber ports
6KQF-1SLCL adds three 10/100 copper and one SM 40Km 100Mb LC fiber ports
6KQF-3SLCL adds one 10/100 copper and three SM 40Km 100Mb LC fiber ports
GUIs for ease-of-use and industry-leading security features, see separate data sheets.
Each Magnum 6KQE base unit may be configured with a choice of 2 modular slots.
6KQE4-2SLC adds two 10/100 copper and two SM 20Km 100Mb LC fiber ports
6KQF-2SLCL adds two 10/100 copper and two SM 40Km 100Mb LC fiber ports
6KQE4-1MMRJ adds three 10/100 copper and one MM 100Mb MTRJ fiber ports
6KQE4-2MMRJ adds two 10/100 copper and two MM 100Mb MTRJ fiber ports
6KQE4-3MMRJ adds one 10/100 copper and three MM 100Mb MTRJ fiber ports
6KQE4-1MLC adds three 10/100 copper and one MM 100Mb LC fiber ports
6KQE4-3MLC adds one 10/100 copper and three MM 100Mb LC fiber ports
6KQE4-2MLC adds two 10/100 copper and two MM 100Mb LC fiber ports
Heavy duty metal case, IP53 for environmental protection, no fans.
http://www.garrettcom.com/techsupport/insertion_guides/6kqecg.pdf
MM= Multi-mode fiber SM= Single-mode fiber
AC 100 to 240VAC, 47 to 63 Hz
Following modules can be configured in Slot C only
6KQE4-RJ45 adds four 10/100 copper ports
Magnum 6KQE (Slot C) Port Modules:
Configuration Options:
PoE-enabled, data pairs

Gigabit (1000Mb) SFP (Small Form Pluggable) Transceiver option (6KQE)
6KQE-2GSFP adds two SFP pluggable open transceiver ports for user selectable SFP

6KQE-1GSFP adds one SFP pluggable open transceiver port for user selectable SFP
ring management. One S-Ring or RS-Ring key is for licensed use one 6K-managed self
Following modules can be configured in Slot D only (Slot D is Gigabit Fiber only)
MNS-6K License- MNS-6K managed software is pre-loaded from the factory.
SFP-LX10 Gb SFP transceiver, 1000Mb-LX, 1310nm wavelength, 10Km
SFP-LX25 Gb SFP transceiver, 1000Mb-LX, 1310nm wavelength, 25Km
SFP-ZX40 Gb SFP transceiver, 1000Mb-ZX, 1550nm wavelength, 40Km
SFP-ZX70 Gb SFP transceiver, 1000Mb-ZX, 1550nm wavelength, 70Km
SFP-SX Gb SFP transceiver, 1000Mb-SX, 850nm wavelength, 550m
SFP-ESX Gb SFP transceiver, 1000Mb, 1310nm wavelength, 2Km
6KQE-2GCU adds two auto-negotiating 10/100/1000Mb copper ports
6KQE-1GCU adds one auto-negotiating 10/100/1000Mb copper port
interior PCBs, PS and modules (for moisture protection)
interior PCBs, PS and modules (for oil and gas industry)
Magnum 6KQE (Slot D) Port Modules:
Gb transceivers in each
with DB-9 connectors.
healing Ring.
Gb transceiver · mount

In the event there are items missing or damaged, contact the party from whom
product; notify the carrier of any damage that you believe occurred during shipment or
delivery. Inspect the contents of this package for any signs of damage and ensure that
Remove the items from the shipping container. Be sure to keep the shipping
shipping container if possible. Refer to Section 6, Troubleshooting, for specific return
Examine the shipping container for obvious damage prior to installing this
2 Set of two metal vertical mounting brackets, with screws to the case
you purchased the product. If the unit needs to be returned, please use the original
(configured with user-selected port module options installed)
1 Magnum 6KQE Managed Edge Switch, base unit
1 6KQE Installation and User Guide (this manual)
container should you need to re-ship the unit at a later date.
This package should contain:
the items listed below are included.
procedures.

Magnum™ 6KQE Managed Edge Switches provide configurability in an entry-
10/100 copper ports (which may be either regular or PoE). Up to 3 100Mb fiber ports or up to four more 10/100 copper ports or combinations, may also be configured. In
software. (MNS-6K-SECURE optional) See the Managed Networks Software (MNS-6K)
level industrial-grade package. The high performance 6KQE base unit comes with four
addition, one or two Gb ports may be configured as 10/100/1000 copper or SFP fiber in
Magnum 6KQEs are ideal for building a switched, hardened Ethernet network
infrastructure, connecting edge devices such as PLCs and IEDs with upstream switches
or routers. Designed for use in industrial applications such as factory floors and control
Advanced thermal design techniques with ribbed–surface Aluminum cases for
mounting, the hardened Magnum 6KQE is a “multi-purpose” Industrial Ethernet Switch.
6KQE handles stressful workloads (mixes of bursty data traffic and priority streaming traffic) as well as harsh environmental conditions.
maximum heat dissipation and a sealed case design enables the unit to operate in harsh
Industrial grade environments efficiently. Heavy duty Ethernet Switch jobs are readily
Component Parts method, or -40˚C to 85˚C by the IEC 60068 Type-Test method. With
Magnum 6KQE comes with the best-of-breed MNS-6K managed networks
tariffed carrier field facilities, or transportation and oil and gas, the rugged Magnum
cabinets, industrial video surveillance systems with PoE, power utility substations,
accommodated with an extended temperature rating of -40˚C to 60˚C by the UL
options such as several popular DC power input types, AC power and DIN-Rail

http://www.garrettcom.com/techsupport/software/datasheets/mns6kds.pdf
datasheet for more information at
any 6KQE base unit.

PoE base unit (6KQEP-48VDC) on Slot A and allows the users to utilize up to 4-ports of
feature supports the 802.3af PoE PSE standard for over-current protection, under-current
Magnum 6KQE Managed Edge Switches have heavy-duty aluminum cases and
and fulfills its role in support of QOS, giving packet processing priority to priority tagged
wireless access points, IP phones) that comply with the IEEE 802.3af PoE standard. The
play” and are designed for use in connecting edge devices such as PLCs, IEDs and PoE
video cameras with upstream switches and routers where a mix of bursty data traffic and
priority streaming traffic for video surveillance and cell-tower applications are present.
DC power options are available. Internal AC power and DC power input types may be
hardware and software through traps, providing a record of any losses of power signals
users from datagram paths that go all across a network. As a LAN device, the Magnum
packets according to the 802.1p standard. In addition to hardware support for QOS, the
The 6KQE managed switches also provides a PoE option via power –inside
PoE to support 802.3af Powered devices. See details for PoE base unit in sec 5.2. The
Power Sourcing Equipment (PSE) is fully compatible with Powered Devices (PD)(e.g
High performance features include non-blocking unicast traffic speed on all
are readily available with standard Industrial grade 24VDC power. Alternative internal
12V, 24V, 48V, 125V, 250V and dual source DC input is optional on the 6KQE. Alarm Relay contacts provided on each Magnum 6KQE Switch monitor the
The Magnum 6KQE switching hardware supports the IEEE 802.1p standard
PoE switch ports have an auto-sensing algorithm, so that they provide power only to
802.3af, PoE end devices. PoE is managed by a multi-stage handshake to protect equipment from damage and to manage power budgets.The PoE ports will
discontinue supplying power when the PoE powered devices are disconnected. This
ports and 802.1p QoS Traffic Prioritization. Magnum 6KQE switches are “plug-and-
Quality of Service means providing consistent predictable data delivery to
MNS software (R2) supports two priority queues that can be shared across the eight
levels of defined packet priorities for application-specific priority control by the user
6KQE can do its part to prevent any QOS degradation while it is handling Ethernet traffic through its ports and buffers.
and other user- defined software events. See Section 3.5 for details.
through software configuration settings.
detection, and fault protection.

CRC, i.e., are good packets. This eliminates the propagation of bad packets, enabling all
impose minimal frame latency, they will also permit bad frames to propagate out to the
traffic. Since there is no way to filter frames with a bad CRC (the entire frame must be
forwarding is greater traffic congestion, especially at peak activity. Since collisions and
Magnum 6KQE’s are store-and-forward switches. Each frame (or packet) is
Ethernet segments connected. The "cut-through" technique permits collision fragment
frames (which are a result of late collisions) to be forwarded which add to the network
operation is that more bandwidth is available for good packets when the traffic load is
temporarily stop sending traffic, which allows the traffic to catch-up without dropping
Another feature implemented in the Magnum 6KQE Switches is a collision-
based flow-control mechanism (when operating at half-duplex only). When the Switch
entering by forcing a collision signal on all receiving half-duplex ports in order to stop
technique ensures that all forwarded frames are of a valid length and have the correct
When the Magnum 6KQE Switch detects that its free buffer queue space is
low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the
detects that its free buffer queue space is low, the Switch prevents more frames from
loaded into the Switch’s memory and inspected before forwarding can occur. This
While other switching technologies (such as "cut-through" or "express")
present in order for CRC to be calculated), the result of indiscriminate cut-through
devices sending it packets to cause “flow control”. This tells the sending devices to
packets. Then, normal packet buffering and processing resumes. This flow-control
bad packets are more likely when traffic is heavy, the result of store-and-forward
sequence occurs in a small fraction of a second and is transparent to an observer.
of the available bandwidth to be used for valid information.
incoming traffic.
greatest.

All MNS-6K software information, and the documentation related to MNS-6K and MNS-
Managed Switch and implements security features and other software enabled features.
v4.1.4 firmware or higher version only, or MNS-6K-SECURE v14.1.4 firmware or
higher version only. Using any earlier MNS-6K versions will not support the 6KQE
Software User guide in pdf format, a separate document normally accessible via your
For interactive training software which shows basic and advanced info about
the Magnum MNS-6K management software and for a useful tool for first time users,
www.GarrettCom.com/techsupport/index.htm#software and look for the
SECURE Rel v14.1.4, which allow the user to configure the Magnum 6KQE as a
For additional information about MNS-6K, see the Magnum MNS-6K
Magnum 6KQE comes with licensed MNS-6K Rel v4.1.4 software or MNS-6K-
Alternatively, for the latest documentation and information, or needed
You may also email: info@GarrettCom.com for further information.
6K-SECURE software, can be accessed at GarrettCom’s FTP site.
or FTP client program at ftp.GarrettCom.com using
visit Magnum MNS-6K Operator Training.
web-browser, at ftp://ftp.garrettcom.com/
GarrettCom’s MIBs for SNMP, visit
Magnum MNS-6K info.
hardware)

provides for this with heavy-duty components. The ambient temperature dual-rating is
Magnum 6KQE Switches provide unicast non-blocking (all ports can run at full speed
Magnum 6KQE Managed Edge Switches are designed to naturally include fiber ports,
Vertical mounting for efficient convection cooling, no fans, extended temperature
Mounting brackets for vertical mounting are included. DIN-Rail mounting hardware
is optional. Ethernet signal and power cables attach at the bottom. Two sets of status
LEDs are included, one set viewable at the port connector and one set viewable from
extra security in their networks. MNS-6K-SECURE is an optional item--licensed per
at once) performance with standard Managed Network Software. They are typically
priority to priority tagged packets according to the IEEE 802.1p standard. For port-
and support mixes of multi-mode, single-mode, 100Mb and 1000Mb speed; full-and
half-duplex; classic Small Form Factor (SFF) and Small Form Pluggable (SFP) fiber
Relay Contacts for monitoring internal power and user-defined software events
signal loss of power internally. The other is software controlled and will signal user-
The 6KQE can be configured with the user’s choice of DC power supplies: 12V and
Heavy-duty design for Industrial Ethernet and extended temperature operation
Two Alarm Relay contacts monitor basic operations. One is for hardware, and will
24V for factory floor, 48V for tariffed carrier field facilities and for PoE-powered applications such as IP video surveillance, and 125V or 250V for substations. An
Magnum 6K-Series Switch, provides power and efficiency in a managed Ethernet
software product enables the versatile Magnum 6K Switches to perform efficiently
Magnum MNS-6K-SECURE software is designed for those customers demanding
The Magnum 6KQE switching hardware supports QoS, giving packet processing
defined software events such as a security violation or an S-Ring fault condition.
internal AC power supply may also be chosen, universal AC for use worldwide.
used in LAN traffic centers with up to 8 100Mb +2 Gigabit ports for backbone
and application-specific priorities of data, the QoS software may be configured.
connectors. RJ-45 10/100 ports can also be configured in the mix of port types.
in a wide range of managed LAN applications, including redundant topologies.
switch. All of the features in regular MNS-6K are included, plus extra security.
Fiber ports take more power than copper ports, but the Magnum 6KQE design
platform. A full range of industry-standard software functions in the MNS-6K
Managed Networks Software (MNS) basic version, combined with a
Switching services includes 802.1p QoS packet prioritization
Managed switching for high performance Ethernet LANs
All types of power input, 12, 24, 48, 125, 250VDC and AC
connections, where managed network services are desired.
60`C per UL methods, and 95°C per IEC type test methods.
MNS-6K-SECURE (optional, for extra security)
MNS-6K licensed Management Software
Fiber Ports Built-In
the front.

S-Ring and Link Loss Learn for economical high availability using ring topology
S-Ring combined with the Link-Loss-Learn feature provides reliable fast recovery of a
may include Magnum switches and routers as well as other vendors industry-standard-
client/server computing, secure VLAN- performance upgrades to departmental networks,
media capability is ideal for integrating future-proof fiber cabling into the LAN structure.
fault in an economical ring topology combining unmanaged and managed switches.
RSTP-2004 provides reliable fast recovery from a fault in a redundant LAN, which
software. Magnum 6KQE Switches are easily used in a variety of applications including
performance characteristics of the 6KQE Switches enable them to inter-connect a series
The mixed-media modular capability is ideal for industrial applications where
RSTP products. Redundant topologies may include rings, dual-rings, and complex
availability. They provide the flexibility of 100Mbps fiber and copper ports as well as
connections may be via fiber or twisted pair cabling, 100Mbps or 10 Mbps speed, and
and stream traffic for VOIP and audio/video applications. They can also be used in a
much diversified combination of mixed media in Industrial floor applications. The
of subnets (one subnet per 6KQE Switch port) in a LAN traffic center. The subnet
existing Ethernet LAN network cabling must be accommodated. The fiber-built-in
Magnum 6KQE Edge Switches offer high performance, modularity and
single or dual Gigabit (1000Mb) ports, with industry-standard LAN management
RSTP-2004 for rings and meshes, fastest fault recovery, interoperability

full-or half-duplex.
meshes.

computers for taking readings and data from Machines, Client/ Server databases, etc. and
reliably. The DIN-Rail Mounting options on the Magnum 6KQE allow the factory floor’s

The option of setting the ports at 10 or 100Mb on copper and 100Mb on fiber
easily connected together with the Fiber ports supported by the Magnum 6KQE Switch.
Equipped with lots of useful features including hardened enclosures, a wide
software features allow this Managed switch to provide a very secure highly available
operated features qualifies this managed switch to operate and perform securely and
sending these important data to the central office data warehouses) very securely and
advance network needs. The modularity of the 6KQE Managed Edge Switches make
organization’s multiple site offices and factory- floors. The different locations can be
spread of DC power supply options, and extended temperature ratings qualifies the
transportation system, or power utility application. The several MNS-6K software
reliably in all critical applications. The addition of S-Ring and the Link-Loss-Learn
The Managed 6KQE’s modularity along with the MNS-6K management
software features remarkably handle industrial environments (i.e. where the factory
floors are networked with Ethernet based mixed-media LANs equipped with PLCs,
A main NT-server in a secure area protected from earthquake or fire hazards can be
Fig 2.5a The industrial factory floor application with Magnum 6KQE
media provide widespread options to the users to mix and match their legacy and
Magnum 6KQE Managed switch for any Industrial factory-floor, traffic control,
industrial user to mount the 6KQE securely anywhere on their Network setup.
them an attractive choice for use in applications with LAN connections to an
redundant network capability in any ring topology network.
connected to the full duplex Gigabit Fiber port.

check the status of other Ethernet units. The entire spread network will be manageable to

The Magnum 6KQE Managed Edge Switch equipped with a mix of copper and
1000Mb. The user can utilize the SNMP feature equipped with VLAN, RMON, STP and
power failure can bring the whole thing down, a ring switch can be reconfigured and up
LAN segments supported by 100Mbps full-duplex future-proof fiber media to provide a
secure long distance LAN connection. The entire network is sharing a higher bandwidth
by providing copper/fiber media along with the higher bandwidth support of 10/100 and
above normal room temperatures occur while the network is in operation. Full-duplex
future proof fiber media can easily connect long distance subnets and provide a stable
secure network to all applications. The SNMP management capability of the Magnum
Gigabit-enabled data-mining server for the vital database located in a separate secured
user-configurable Magnum 6KQE provides an extra boost to the network requirements
networks and many other temperature sensitive critical Industrial applications where
6KQE Switch helps create a database of all the network subnets to easily manage the network.
maximum redundancy. In a network where any faulty cable, cable disconnection or
and running in milliseconds. The ring topology of the network consists of high speed
building. The copper ports are required for multiple subnets inside the power plant to
Fig 2.5b Magnum 6KQE equipped with S-Ring in redundant ring solution
fiber ports provides an economical and seamless solution to many requirements. The
Extended temperature ratings and a variety of options for AC/DC power
provide easy, detectable, uninterrupted support through a viewable SNMP monitor.
supplies qualify this managed 6KQE switch for use in non-temperature controlled

breakup when set up in a ring topology. The Gigabit port option boosts the bandwidth for
to cover the wider area of video CCTV. The switch must be SNMP enabled and managed
the edge switch provides a very effective and economical solution for the video -vignette
compliant, 24VDC managed switch is required to meet the fiber and copper connections
the various features and modularity it has. Loaded with MNS-6K management software,
The security features (e.g. port-security, VLANs, SNMPv3, secure telnet, etc.)
10/100/1000Mb speeds easily meets the various speeds of legacy and future broadband requirements.
In a fast growing secure video environment, the 6KQE is a reliable and secure
copper/fiber options to meet requirements. The Gigabit uplink for storage or broadband
The 6KQE Managed Fiber with S-ring and Link-Loss-Learn features easily
fulfill the redundant requirement with a secure and fast reconfiguration time for cable
The Magnum managed edge switch easily qualifies for this requirement with

uplink allows the telecom user a very effective solution to store their sensitive data
also boost the Magnum managed switches to provide a very effective and reliable
Fig 2.5c Magnum 6KQE deployed in a video security CCTV application for
other standard managed LAN features to provide a secure and stable network.
solution. The modular design of the Magnum 6KQE, provides a wide range of
solution. The modularity feature to support both copper and fiber at either
high speed to support the peak traffic and minimize congestion.
monitoring and securing the premises
to easily monitor the whole setup.
environment.
securely.

3.0 INSTALLATION Before installing the equipment, it is necessary to take the
1.) If the equipment is mounted in an enclosed or multiple rack assembly, the steady-state long-term environmental temperature
2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate airflow must be maintained for proper and
3.) If the equipment is mounted in an enclosed or multiple rack system, placement of the equipment must not overload or load
4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent
This section describes installation of the Magnum 6KQE Switches, as well as connection
5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and
visually monitor the status LEDs. Keep an open area around the unit so that cooling can
silent when in operation. Internal electronics use the case as a heat sink, so the unit may
The rugged metal case of the Magnum 6KQE will normally protect it from
accidental damage in a lab or workplace setting. Maintain an open view of the front to
occur from convection while the unit is in operation. The 6KQE has no fans, so it is
around the equipment must be less than or equal to 600C.
For DC power input data, see Appendix B. For Dual Source, see Appendix C
overloading of the building/s electrical circuits.
For vertical panel mounting and wall mounting, see Section 3.3
For vertical DIN-Rail mounting, see Section 3.3.1
uncompromised earthing path.
following precautions:
unevenly the rack system.
of the various Ethernet media types.
normally be quite warm to the touch.
safe operation.

See http://www.garrettcom.com/techsupport/power_budget.pdf for Power budget
The following procedure describes how to connect a 10BASE-T or 100BASE-TX
The various media types supported along with the corresponding IEEE 802.3,
The RJ-45 ports of the Magnum 6KQE can be connected to the following two
100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100
Ethernet media types within a single Switch unit. This is accomplished by using a two
Twisted Pair (CAT 3 or 5) 10BASE-T RJ-45
in order to provide flexibility in a mixed-speed network, since 10/100 copper
The Magnum 6KQE Switches are specifically designed to support standard
802.3D, 802.3u, 802.3AB and 802.3z standards and connector types are as follows:
Twisted Pair (CAT 5) 100BASE-TX RJ-45
Fiber (Multi-mode) 100BASE-FX MTRJ, LC
twisted pair segment to the RJ-45 port. The procedure is the same for both
Media IEEE Standard Connector
Fiber (Multi-mode) 1000BASE-SX LC (SFP)
Fiber (Multi-mode, Single-mode) 1000BASE-LX LC (SFP)
Fiber (Single-mode) 1000BASE-ZX LC (SFP)
popular Fiber Connectors which can be individually selected and configured.
shielded, either unshielded or shielded cables and wiring may be used.
Twisted pair (CAT5E or CAT6) 1000BASE-T RJ-45
Fiber (Single-mode) 100BASE-FX LC
switched ports are auto-sensing for either 10 and 100Mb/s.
calculations, to find fiber cable distance information.
unshielded and shielded twisted pair cables.
(See Section 5.1 for a description of the Modules)
meters (328 ft).

(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx
advises that, for substation applications, the RJ-45 ports are intended for connectivity to
The RJ-45 Gigabit ports of the Magnum 6KQE can be connected to the media
The following procedure describes how to connect a 1000BASE-T twisted pair segment
connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable
recommended to use these ports in substation applications to interface to field devices
types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)
balanced cable is recommended to use when making 1000BASE-TX connections. In
either case, the max distance for unshielded twisted pair cabling is 100 meters (328 ft).
to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted
are the diameters of the core and the core plus the cladding respectively). Single-mode
fiber allows full bandwidth at longer distances, about 70km with the single-mode LC.
balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)
When using single-mode fiber cable, be sure to use single-mode fiber port
other communication equipment such as routers or telecommunication multiplexers
1613specifications for zero packet loss with fiber ports & with RJ-45 ports used as indicated here.
installed in close proximity (i.e., less than 2 meters or 6.5ft) to the 6KQE. It is not
across distances which could produce high (greater than 2500V ) levels of ground
potential rise (GPR) during line-to-ground fault conditions. The 6KQE passes the
3.2.3 Connecting Single-Mode Fiber Optic
cables and wiring may be used.
pair cables.

The small form-factor pluggable (SFP) is a compact optical transceiver used in
applications. Due to its compact, hot pluggable characteristics, SFPs are becoming a very
All SFPs used in Magnum 6KQEs are compliant with the industry standard Multi-Source
removing the SFP transceiver for any reason. Not removing the fiber cable
first can damage the fiber cable, cable connector or optical interfaces. It is
intervals; you must use the color-coded strand on the associated ports at each end of the
popular choice for various applications. The small-chassis Magnum 6KQE is designed
other device, it is recommended to use Crossover RJ-45 (4-twisted pair) category 5 or
advised not to remove and insert a SFP transceiver frequently as this may shorten its
connecting to any Server/workstation. While connecting with any Switch/repeater or
tissue dampened in alcohol. Make certain the connectors are clean before
the tips of the connectors on the PM. Save these dust caps for future use.
for industry-standard Gb-SFPs for user selection of the SFP gigabit media type as
Agreement (MSA) ensuring compatibility with a wide range of networking kit.
recommended to use a straight-through RJ-45(4-twisted pair) connection while
optical communications for both telecommunication and data communications
higher cabling. The maximum length supported on copper 1000BASE-T is
(see Section 1.2 for the SFP’s available for the 6KQE)
since the SFP modules are static sensitive devices.
connecting.
fiber optic segment.
100m (328 ft.).
useful life.
desired.

If connected properly, you can check via (MNS-6K) software for verifying the validity of
For best cooling of the 6KQE, attach the metal brackets to metal (rather than wood
or plastic). Attaching to metal helps conduct heat away from the 6KQE through the
transceiver carefully, until the transceiver connector snap into the place in the
polarity. Swap the fiber cables at the PM connector and also check the connectivity on
Each Mangum 6KQE is supplied with metal mounting brackets and screws to
vertically, as shown on following page, for proper cooling and long-life reliability. It is
panel or wall behind it, creating a rear space of about ¼ inch or 1cm. This allows
Since the 6KQE has special internal thermal techniques (patent pending) to move
the heat generated by the electronic components inside into the case, the case may
The LINK LED on the front of the PM will illuminate and turn Green, when a proper
connection has been established at both ends (and when power is ON in the unit). If
also advisable to mount the unit with space for air movement around the top and the
verify the top side of it. Some of the transceiver marks arrow sign for up.
mount the unit securely on a panel or wall. It is recommended to mount the 6KQE
LINK is not lit or OFF after cable connection, the normal cause is improper cable
of the remote device. Connect the Receive (RX) port on the PM to the
air circulation and cooling of the rear part of the case.
be quite warm to the touch during normal operation.
metal brackets and into the metal support structure.
Reconfigure or reboot both of the devices if required.
Transmit (TX) port of the remote device.
the target device to remedy this situation.
sides, typically a minimum of 1 inch.
socket connector.
SFP Gigabit ports.


for the mounting screws into the supporting wall or panel is a rectangle 21.74 x 11.91 cm
vertically for proper convection cooling of the
be ordered as Model # DIN-RAIL-6KQ. See a
The DIN Rail bracket is mounted on
To install the 6KQE with the DIN-Rail
environment. It is available with an optional DIN-Rail bracket to mount it securely in a
6KQE viewed from the side, at the rear, with model DIN-RAIL-6KQ in place on the unit.
one of three available positions at the rear of
mounting purposes. The required four screws
The unit is mounted using the brackets as shown in the illustration above. The spacing
unit. The Magnum 6KQE requires one DIN-
Rail bracket for secure mounting. This may
provided on the rear of 6KQE for DIN-Rail
are included with the DIN-Rail bracket, and
bracket installed, hold the 6KQE in the side
metal factory floor enclosure, maintained
the 6KQE unit. Eight threaded holes are
The Magnum 6KQE is designed for use in a “factory floor” industrial
are no.4-40 X 5/16 PHIL. PAN Head.

(8.56 x 4.69 inches) center-to-center.

The DIN-Rail mounting bracket is optional and needs to be ordered as separate
consumption will range from about 15 up to 20 watts, depending on the port quantity and
holding position by moving the bottom of the 6KQE inwards to a vertical position. The
DIN-Rail bracket is heavy duty, and will hold the 6KQE securely in position, even with
To release the 6KQE from the DIN-Rail mounting, press the top of the DIN-Rail
vertical position with the bottom out, and with the top moved in toward the DIN-Rail.
The DC internal power supply supports installation environments where the
types in the configuration.. When connecting the Ethernet cabling, there is no need to
Power input options are available to suit the 6KQE Switches to special high-
bracket slide DOWN to release the 6KQE so that it can be dismounted by pulling the
bottom out. Once the bottom of the 6KQE is rotated out, the DIN-Rail bracket is not
Position the DIN bracket over the top of the DIN-Rail. Then, snap the bracket into
power down the unit. Individual cable segments can be connected or disconnected
availability communications and/or heavy industrial-grade applications, including:
engaged and the 6KQE can be moved up and out, free of the DIN-Rail mounting.
DC voltage is from 10 to 300 volts depending on the model selected. The power
* 12VDC, -48VDC, 24VDC, 125VDC and 250VDC with dual-source DC input * AC input with internal power supply (see Section 1.2, for Ordering Information)
* 12VDC, -48VDC, 24VDC, 125VDC and 250VDC with single DC input,
without concern for power-related problems or damage to the unit.
items, e.g Model # DIN-RAIL-6KQ
cabling attached to the unit.

The Alarm Contacts feature, standard on Magnum 6KQE’s, provides two Form
close during normal software operation. A user-defined software malfunction, such as an
When the Software Alarm is enabled, the Form C Normally Closed (NC) contact is held
The second NC Alarm Contact is held closed when there is power on the main
board inside of the Switch. This provides a “Hardware Alarm” because the NC contacts
The Alarm Contacts are on the front left area (next to the DC power source) of
monitoring wires at the green terminal block. When this option is present, the terminal
disable the Software Alarm feature with a software configuration command if desired.
SNMP Trap or a Software Security violation or an S-Ring Fault, causes the contact to
will open when internal power is lost, either from an external power down condition or
block for Alarm Contacts is part of the Power Input panel in the 6KQE case. The DC
“Software Alarm”, operated by user settings in the MNS-6K software. The user can
The first NC Alarm Contact (top position, switch vertically mounted) is a
C Normally Closed (NC) contacts to which the user can attach two sets of status
Fig 3.5a Alarm Contacts:
(1,2) are hardware operated
(3,4) are software operated
the Magnum 6KQE unit and are green in color as shown in the picture.
traps, please reference the Magnum MNS-6K Software User Manual.
by the failure of the power supply inside of the Magnum Switch.
open and thus triggers an alarm in the user’s monitoring system
power input connection is in the same panel.

Useful info. about Alarm contacts:

Use a (DB-9) “null modem” cable to connect the Magnum 6KQE Console Port
The above provided information enables a managed station (a PC or Console terminal) to
(the RS-232 port on the 6KQE Switch) to your PC, so that your PC becomes
female to female cable is required to communicate properly. The Null-Modem (DB-9)
1 DCD Data Carrier detect (not used)
Magnum 6KQE Switch configuration for Network Management, please refer to
3 TXD Transmit Data (output)
cable is optional and can be ordered from the factory, along with the unit as-
2 RXD Receive Data (input)
Magnum 6K Software Manual available on GarrettCom‘s FTP site.
7 RTS Request to Send
5 GND Signal Ground
http://www.garrettcom.com/techsupport/sw_downloads.htm
8 CTS Clear to Send
DB-9 (Console port connector)
4 open not used
6 open not used
9 open not used
connect directly to the switch using a straight through cable.
the 6KQE Console Terminal.
Also available on GCI website at:
CONSOLE CBL for serial port
CONSOLE USB for USB port

intended for temporary connectivity to other equipment such as PCs. Since the
100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance. All ports can communicate to all other ports in a Magnum 6KQE,
configured through MNS software per unit as per the requirement. The internal functions
Each time a packet arrives on one of the switched ports, the decision is taken to
either filter or to forward the packet. Packets whose source and destination addresses are
on the same port segment will be filtered, constraining them to that one port and relieving
is on another port segment will be forwarded to the appropriate port, and will not be sent
interrupted operation of the network (such as occasional multi-cast packets) is forwarded
the rest of the network from having to process them. A packet whose destination address
mode, which eliminates bad packets and enables peak performance to be achieved when
removed or moved from one segment to another, the 6KQE Switch automatically keeps
An address-aging algorithm causes least-used addresses to fall out in favor for
advises that, for substation applications, the serial (DB-9) console ports are
console port connection is temporary, it is excluded from IEEE 1613 packet-
among all of its ports. The Magnum 6KQE supports10/100Mbs for copper media and
configuring necessary to be done for basic operation at installation or for maintenance.
All Magnum 6KQE units have address table capacities of 4K node addresses
The Magnum 6KQE units are plug-and-play devices. There is no software
(resides inside the unit) on the 6KQE4-RJ-45. There is an optional Half / Full duplex
A Magnum 6KQE provides switched connectivity at Ethernet wire-speed
but local traffic on a port will not consume any of the bandwidth on any other port.
The only hardware configuration settings are user options for an UP-LINK Switch
The Magnum 6KQE Switches operate in the store-and-forward switching
frequently-used addresses. To reset the address buffer, cycle power down-and-up.
This chapter describes the functions and operation of the Magnum 6KQE Switch.
suitable for use in larger networks. They are self-learning, so as nodes are added,
mode and 10Mbps or 100Mbps selection for the switched ports which must be
to the other ports where it is not needed. Traffic needed for maintaining the un-
loss testing per the 1613 standard-defined test procedure.
there is heavy traffic on the network.
of both are described below.
up with node locations.
to all ports.
Filtering and Forwarding · Address Learning

copper ports is to connect one of them using a fiber media converter to another Switch in
desirable to operate the fiber link at 100Mb speed, and at either half- or full duplex mode
possible depending on what the other device supports. These are: (1) 100Mb full-duplex,
the device at the other end is not an auto-negotiating device, the 6KQE’s RJ-45 ports will
selection is made via MNS software. The factory default setting is for auto-negotiation.
At 10Mb or 100Mb-fixed speed, the user may select half- or full-duplex mode by MNS
require that the switched port to which they are connected be at the 100Mb fixed speed.
6KQE Switch’s RJ-45 ports handle this situation by configuring the ports as per desired through MNS software port settings and can check the port status of each port after the
When Magnum 6KQE RJ-45 copper ports are set for auto-negotiation and are
connected to another auto-negotiating device, there are 4 different speed and F/H modes
The auto-negotiation logic will attempt to operate in descending order and will normally
mode” result can change at any time depending on network changes that may occur). If
try to detect its idle signal to determine 10 or 100 speed, and will default to half-duplex
Software for each RJ-45 port separately. For detail information See Section 2.3 of this
arrive at the highest order mode that both devices can support at that time. (Since auto-
The RJ-45 ports independently support auto-cross (MDI or MDIX) in auto-
RJ-45 ports whether they support Auto-negotiation (e.g 10Mb Hub, media converter)
depending on the capabilities of the remote device. Standard commercially available
Fast Ethernet media converters mostly do not support auto-negotiation properly, and
Attachments to a 10/100 auto-negotiation port typically will not work properly. The
negotiation is potentially an externally controlled process, the original “highest order
Auto-negotiation per-port for 802.3u-compliant switches occurs when:
negotiation mode and will work properly with all the other connected devices with
The Managed 6KQE’s Fast Ethernet copper ports can be set for either fixed 100Mb
speed or for 10/100 F/H N-way auto-negotiation per the IEEE802.3u standard. The
One frequently-used application for the Managed Magnum 6KQE Switch
-- the devices at both ends of the cable are capable of operation at either
cross-over cable is required while using the 6KQE’s copper port to other devices.
4.2 Auto-Cross(MDIX) and Auto-negotiation, for RJ-45 ports
or fixed mode at 10Mb or 100Mb Half/Full Duplex(managed switch) or not. No
the network backbone, or to some other remote 100Mb device. In this case, it is
10Mb or 100Mb speed and/or in full- or half-duplex mode, and can
(2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex.
manual for information to access the “6K-MNS Software user guide”
send/receive auto-negotiation pulses, and . . .
Operation is according to the IEEE 802.3u standard.
at that speed per the IEEE standard.
change.
General information -

that they are in is powered. These are exceptions to the “negotiate at LINK –
may be limited within that collision domain. The Path Delay Value (PDV) bit-times must
10Mb port is unable to keep up. It can also occur when multiple 100Mb ports are attempting to transmit to one 100Mb port, and in other protracted heavy traffic situations.
Magnum 6KQE Switches implement the 802.3x flow control (non-blocking) on
burst of activity causes the switch to save frames until its buffer memory is full. This is
Full-Duplex ports, which provides for a “PAUSE” packet to be transmitted to the sender
buffer queue increases, the Switch will send a “RESUME" packet to tell the transmitter
802.3x flow control standard in order to communicate properly during normal operation.
algorithm on 10/100 Mb ports for flow control. That is, the switch prevents frames from
receiving. This temporary “collision” delay allows the available buffer space to improve
When operating in 100Mb half-duplex mode, cable distances and hop-counts
account for all devices and cable lengths within that domain. For Magnum 6KQE Fast
sufficient time to let the Switch reduce the buffer space used. When the available free-
Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.
Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long
most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the
transmitting device is commanded to stop transmitting into the 6KQE Switch port for
to start sending the packets. Of course, the transmitting device must also support the
entering the device by forcing a collision indication on the half-duplex ports that are
Magnum 6KQE Switches incorporate a flow-control mechanism for Full-
-- the second of the two connected devices is powered up*, i.e., when
-- the LINK is re-established on a port after being lost temporarily.
when the packet buffer is nearly filled and there is danger of lost packets. The
enabled” rule above, but may be occasionally encountered.
as the switch catches up with the traffic flow.
LINK is established for a port, or

See http://www.garrettcom.com/techsupport/power_budget.pdf for more information on
four ports (1,2,3 & 4) of the Magnum 6KQE Switches are fixed RJ-45 copper ports with
dual-speed 10/100Mbps auto-negotiating capability. Additionally the switch can accept
providing a wide selection of Ethernet copper and fiber media connections with 10, 100
6K products such as the 6K25e and 6K16V. For information about other
Receiver Sensitivity and Transmitter Power are the parameters necessary to
5.1 6KQE Modules An important feature of the Magnum 6KQE is the use of Port Modules for
flexible mixed-media connectivity to RJ-45 copper and various fiber media. The first
6K products, please see the applicable manual. For a list of 6KQE Port
compute the power budget. To calculate the power budget of different fiber media
where the “Cable Loss” for 62.5/125 and 50/125μm (M.m) is 2.8 dB/km,
Each 6KQE Port Module (PM) is individually described in the following sections.
up to two Port Modules to provide the user with up to 6 additional ports (10 total)
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km (ZX40)
This chapter describes each Port Module (PM), including appearance,
installations using Magnum products, the following equations should be used:
and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LX25)
and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (ZX70)
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
OPB (Optical Power Budget) = PT(min) - PR(min)
functionality, and status displays.
and 1000Mbps capability and up to 70km.
Modules, refer to Section 1.2
Power budget calculations

1= ON (Full Dx), OFF (Half Dx) 2= ON (Link) 3= BLINKING (Activity) 4= ON (1000Mb) Not used for Fiber 5= ON (100Mb) Not used for Fiber 6= ON (10Mb) Not used for Fiber
Gigabit (Copper / Fiber)
2= ON (Link), BLINKING (Link/Activity)
3= ON (Full Duplex), OFF (Half Duplex)
3= ON (Full Duplex), OFF (Half Duplex)
1= ON (100Mb), OFF (10Mb)
4= ON (PoE device detected)



2= BLINKING (Activity) · 1= ON (Link) · LC (Fiber)

independently N-way auto-negotiating and auto-crossover (MDIX) for operation at 10 or
100Mb speed in full- or half-duplex mode. (i.e., each independently selects a mode and speed to match the device at the other end of the twisted pair cable).
The 6KQE4-RJ45 4-port Copper module provides four 10/100Mb switched
RJ-45 ports. The 10/100Mb switched ports normally (as a default setting) are
5.1.2 6KQE Base Unit LED designations

6KQE Base Unit – Top label

indicates receiving Activity on that port when lit. The 10/100 LED indicates operation at
indicate the half-duplex mode. A twisted pair cable must be connected into an RJ-45 port
user may select 10Mb or 100Mb speed and full- or half-duplex mode per-port as per user

could produce high (greater than 2500V ) levels of ground potential rise (GPR)
indicates “ready for operation” on that port when lit. The blinking ACT (Activity) LED
device at the other end of the cable) in order for a LK LED to provide valid indications
user may disable auto-negotiation and fix the desired operation of each RJ-45 port. The
On the model 6KQE4-RJ45 module, there are four LEDs for each port, two
and the Link (LK) indicator for that port must be ON (indicating there is a powered-up
Using the 6K (MNS-6K or MNS-6K-SECURE) management software, the
telecommunication multiplexers installed in close proximity (i.e., less than 2
1613specifications for zero packet loss with fiber ports and with RJ-45 ports used as indicated here.
choice for 100Mbps “fiber-to-the-desktop” Ethernet connectivity. When installed in a
(for auto-negotiation and MDIX details, see Section 4.2 in the 6KQE User Guide).
100Mb speed when ON and at 10 Mb speed when OFF (when auto-negotiation is not disabled). The FDX/HDX LED is ON to indicate full-duplex operation and OFF to
substation applications to interface to field devices across distances which
Multimode connector. The MTRJ’s small size and ease of connection make it a good
Magnum 6KQE Series Switch, it supports fiber optic cable distances up to the IEEE-
advises that, for substation applications, the RJ-45 ports are intended for
meters or 6.5ft) to the 6KQE. It is not recommended to use these ports in
The 6KQE4-1MMRJ 4-port Fiber / Copper module provides one 100Mb
integrated into the connector, and two below the connector. The LK (Link) LED
The 6KQE4-1MMRJ fiber port is a Small Form Factor (SFF) MTRJ
requirements. (See Magnum MNS-6K Software Manual for additional info)
connectivity to other communication equipment such as routers or
Multimode MTRJ Fiber port and three 10/100Mb switched RJ-45 ports.
of operating conditions on that port.

shielded twisted pair (STP) cable connections. When installed in a Magnum 6KQE Series

Multimode MTRJ Fiber ports and two 10/100Mb switched RJ-45 ports. (see also Section

Each port has an Activity (ACT) LED indicating packets being received and a
any standard length. It is equipped with a three-port RJ-45 connector, and offers 10/100
option occupies parts of Slot “A” and Slot “C”. (see also Section 5.1.4 for information)
The 6KQE4-1MMRJ copper ports support Ethernet twisted pair segments of
shielded to minimize emissions and will allow both unshielded twisted pair (UTP) and
Managed Switch, the copper ports support the standard distance of 100m on each port.
standard 100Mbps distance limits, i.e., typically 2km at full-duplex and 412m at half-
The 6KQE4-3MMRJ 4-port Fiber / Copper module provides three 100Mb
Link (LK) LED that indicates proper connectivity with the remote device when lit.
The 6KQE4-2MMRJ 4-port Fiber / Copper module provides two 100Mb
Multimode MTRJ Fiber ports and one 10/100Mb switched RJ-45 port. This module
full / half-duplex auto-negotiating capability on each port. The RJ-45 connector is
5.1.6 6KQE4-3MMRJ, 3 x MTRJ / 1 x RJ45 (Slot A, Slot C)
5.1.4 for additional information)
duplex.


The 6KQE4-1MLC copper ports support Ethernet twisted pair segments of any
standard length. It is equipped with a three-port RJ-45 connector, and offers 10/100 full /
half-duplex auto-negotiating capability on each port. The RJ-45 connector is shielded to
wiring closets while providing the advantage of “future-proof” fiber optic technology.
The cable end is a “plug-in” connector with both fiber strands terminated in
one housing that cannot be improperly inserted. Each port has an Activity (ACT) LED
indicating packets being received and a Link (LK) LED indicating proper connectivity
Managed Switch, the copper ports support the standard distance of 100m on each port.
The 6KQE4-1MLC fiber port is a Small Form Factor (SFF) LC Multimode
connector used primarily in 100Mbps fiber-to-the-desktop links. When installed in a
Magnum 6KQE Series Switch, it supports fiber optic cable distances up to the IEEE-
standard 100Mbps distance limits, i.e., typically 2km at full-duplex and 412m at half-
The compact size of the LC Connector reduces the size of wiring panels in
minimize emissions and will allow both unshielded twisted pair (UTP) and shielded
The 6KQE4-1MLC 4-port Fiber / Copper module provides one 100Mb
twisted pair (STP) cable connections. When installed in a Magnum 6KQE Series
Multimode LC Fiber port and three 10/100Mb switched RJ-45 ports.
with the remote device when lit.
duplex.



These modules provide the same functions as the Multimode versions (see Sections 5.1.7
These modules provide the same functions as the Multimode versions (see Sections 5.1.7
Multimode LC Fiber ports and one 10/100Mb switched RJ-45 ports. This module option
The 6KQE4-xSLC 4-port Fiber / Copper modules provide 100Mb Singlemode
The 6KQF-xSLCL 4-port Fiber / Copper modules provide 100Mb Singlemode
LC Fiber ports, supporting distances up to 20km , and 10/100Mb switched RJ45 ports.
LC Fiber ports, supporting distances up to 40km , and 10/100Mb switched RJ45 ports.
The 6KQE4-3MLC 4-port Fiber / Copper module provides three 100Mb
The 6KQE4-2MLC 4-port Fiber / Copper module provides two 100Mb
occupies parts of Slot “A” and Slot “C”. (see Section 5.1.7 for more information)
5.1.11 6KQF-xSLCL, LC Singlemode (40km) / RJ45 Module
Multimode LC Fiber ports and two 10/100Mb switched RJ-45 ports.
5.1.9 6KQE4-3MLC, 3 x LC / 1 x RJ45 (Slot A, Slot C)
thru 5.1.9 for more detail and panel configurations).
thru 5.1.9 for more detail and panel configurations).
(see Section 5.1.7 for more information)



There are six LEDs provided for each Gigabit port. Each Copper Gigabit port
10/100/1000Mb RJ-45 ports. The Magnum 6KQE offers a Gigabit option with multiple choices of Copper
10/100/1000Mbps or Gigabit SFP Fiber transceivers for the modular slot. Up to two Gigabit ports (maximum) can be configured in Slot D only.
transceiver locations that can operate at 10/100/1000Mbps speeds. Transceivers are
The 6KQE-2GSFP 2-port Fiber Gigabit module provides two SFP open
has LEDs that indicate FH (Full or Half Duplex), LK (Link), ACT (Activity) and
The 6KQE-2GCU 2-port Copper Gigabit module provides two fixed
The 6KQE-1GCU 1-port Copper Gigabit module provides one fixed
10/100/1000Mbps speed (set to AUTO by default).
10/100/1000Mb RJ-45 port.

LEDs are configured the same as the copper gigabit option. (see Section 5.1.12

except they have the capability of providing power on each port to power up attached PD
properly to an IEEE 803.af compliant PD device on that port. When non-PoE devices are
devices. The PoE LED is ON when the attached PD is drawing power from the
The 6KQE is available with the option of having PoE capabilities on the four
The PoE (Power-over-Ethernet) RJ-45 ports are similar to regular RJ-45 ports,
PoE. LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that
port. The power is supplied on the data pairs, per IEEE802.3af PoE standard.
strong enough to provide power to the 6K switch and to all 4-RJ-45 ports with
available with both multi-mode 850nm (550m), 1310nm (3km), single-mode 1310nm
(10/100) ports. Each port supplies up to 15watts to power attached PoE PD devices.
The LEDs on the PoE ports are slightly different compared to regular (non-
PoE) RJ-45 ports. When the PoE port is in use, the PoE LED is ON when connected
connected, the PoE LED is OFF. Operation of Ethernet data traffic is not affected by
through, so the 48VDC power input source to the Magnum 6KQE must be
The 1000Mb Gigabit SFP fiber-port modules on the Magnum 6KQE are
normally set (factory default) to operate at AUTO mode for best fiber distance and
The 6KQE-1GSFP 1-port Fiber Gigabit module provides one SFP open
devices, per the IEEE802.3af PoE standard. The power-pass-through PoE ports are
dependent upon the -48VDC input power to supply the PD power for these RJ-45
(10km and 25km) and single-mode 1550nm (40km and 70km) fiber options.
and the PoE LED is OFF. No power is sent out from the port.
transceiver location that can operate at 10/100/1000Mbps speeds.
PD devices connected (up to 15 watts per PoE port).
fixed RJ45 ports in the base unit (ports 1, 2, 3 and 4).
(see page 5 of this manual for part numbers)
is marked as LINK/ACT.
performance.
PoE LEDs Summary · above)

port pins and no power is coming to the PoE ports for some reason, all the PoE
suggestions listed below prior to contacting your supplier. However, if you are unsure of
known good device. Verify whether or not the problem is corrected. If not, go
to Step 5 below. If the problem is corrected, the Magnum 6KQE Switch and its
intended to help locate, identify and correct these types of problems. Please follow the
Switch product, it is recommended that the problem device be replaced with a
of the Magnum 6KQE Switch unit or if unknown, contact GarrettCom, Inc. by
port LEDs are ON simultaneously to indicate a trouble condition. The ports
performing as expected, do not attempt to repair the unit; instead contact your supplier
the Installation Section of the applicable chapter of this manual. Also check
d. Any particular application that, when used, appears to create the problem;
to make sure that the various components of the network are interoperable.
consistently high performance in all network environments. The installation of a
Should problems develop during installation or operation, this section is
impaired during installation. (About 90% of network downtime can be
All Magnum Ethernet products are designed to provide reliability and
connected and the cables/wires have not been crimped or in some way
Magnum 6KQE Switch is a straight forward procedure. The operation is also
the procedures described in this section or if the Magnum 6KQE Switch is not
unit. Use the PWR LEDs to verify each unit is receiving power.
straightforward and is discussed in Section 4.0 of this 6KQE User Guide.
fax, phone or email (support@garrettcom.com) for assistance.
will still operate properly for data traffic to non-PoE devices.
Please be prepared to provide the following information.
for assistance or contact GarrettCom Customer Support.
attributed to wiring and connector problems.)
c. The components involved in the problem;
associated cables are functioning properly.
a. The nature and duration of the problem;
b. Situations when the problem occurs;
6.2 When Calling for Assistance
6.0 TROUBLESHOOTING

All returns for repair must be accompanied by a Return Material Authorization
including personal computers, workstations, terminals and printers; plus, the
https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.
GarrettCom will carefully test and evaluate all returned products, will repair products
number(s). Include the date(s) that you purchased the products from your
to the occurrence of the problem. Any changes to system administration
that are under warranty at no charge, and will return the warranty-repaired units to
the sender with shipping charges prepaid (see Warranty Information, Appendix A,
units under warranty. Testing and repair of product that is not under warranty will
GarrettCom reserves the right to charge for the testing of non-defective
for complete details). However, if the problem or condition causing the return
Failure symptoms, including a full description of the problem.
6.3 Return Material Authorization (RMA) Procedure
(RMA) number. To obtain an RMA number, please use this URL -
cannot be duplicated by GarrettCom, the unit will be returned as:
Name and phone number of your contact person.
Please have the following information readily available:
Packing List Number (or Sales Order Number)
procedures should all be noted in this record.
various network media types being used.
No Problem Found.
Name of your company / institution
Serial Number (or Invoice Number)
result in a customer (user) charge.
supplier.
Your shipping address · Date of installation · Product name

sheet or bag for shipping protection. ( You may retain all connectors and this
material. This material may cause electro-static shock damage to the unit.
GarrettCom, Inc. warrants its products to be free from defects in materials
replace components in the products that prove to be defective at no charge other
product has been damaged by misuse, misapplication, or as a result of service or
This warranty will not be effective if, in the opinion of GarrettCom, the
and workmanship for a period of three (3) years from the date of shipment by
than shipping and handling, provided that the product is returned pre-paid to
inspecting any product returned for warranty repair which turns out not to be
During this warranty period, GarrettCom will repair or, at its option,
GarrettCom reserves the right to make a charge for handling and
Should you need to ship the unit back to GarrettCom,
6.4 Shipping and Packaging Information
47823 Westinghouse Dr.
Attn.: Customer Service
modification other than by GarrettCom.
please follow these instructions:
GarrettCom, Inc.
Installation Guide.)
GarrettCom.
GarrettCom.
faulty.
Fremont, CA 94539

24, 48, 125 and 250VDC nominal. The wide range of DC power input types qualifies this product for use in 12, 24, 48, 125 and 250VDC applications in different industries.
inputs. It protects the Switch from incorrect DC input connections. An incorrect polarity
Each Magnum Model 6KQE Managed Switch requires DC power input, at 12,
allows the Switch to operate only whenever DC power is correctly applied to the two
B2.0 12, 24, –48, 125 and 250VDC POWER, THEORY OF OPERATION

See also Section 1.0, Technical Specifications, for the 6KQE base unit
12VDC Power Input nominal (range 8 to 18VDC)
B1.0 Specifications for Magnum 6KQE Switches, DC Power at 12, 24,
20 watts typical (for a fully loaded fiber model with 2Gb) 15 watts typical (for 8 ports, copper and 100Mb fiber)
Standard 6KQE DC Power Input Terminal Block: “ -, GND, + ”
125VDC Power Input nominal (range 88 to 150VDC) 250VDC Power Input nominal (range 160 to 300VDC)
24VDC Power Input nominal (range 18 to 36VDC) -48VDC Power Input nominal (range 36 to 60VDC)
–48, 125 and 250VDC Power input
Fig B1.0 Location of chassis ground
power from an external source can
125 and 250VDC power options are designed using diodes inside
connection terminals, so that the
The 12, 24, -48VDC,
behind the two external power
on each DC power input line
only flow into the hub. This
Power Consumption:

connection, for example, will neither affect the Switch, its internal power supply, nor will
Magnum 6KQE Switches are easily installed in a variety of applications where
The –48VDC solution is particularly useful in the telecommunication industry,
other communication companies. In addition, many high availability equipment services,
facilities often use a battery backup system to maintain operations in the event of a power
identified as positive (+) and negative (-), and they are electrically floating inside the unit
The connection procedure is straightforward. Simply insert the DC leads to the
(GND) connects to the Switch chassis screw provided under the DC terminal. Ensure that
12, 24, -48VDC, 125 and 250VDC power is used as the primary power source. The DC power configuration capability provides an Ethernet networking solution utilizing a
where it is common for facilities to operate on -48VDC power. Such companies include
environment, where it is common for facilities to operate on 24VDC or 125VDC power.
industrial automation such as factory floor, process plants, HVAC, military equipment,
250VDC leads to the DC power terminal block on the Magnum 6KQE Switch. The DC terminal block on the Magnum 6KQE Managed Switch is located on the left front of the
and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead
regular and wireless telephone service providers, Internet Service Providers (ISPs) and
The 125VDC options are mainly used in power utilities, such as electrical substations,
so that either may be grounded by the user if desired. The chassis is “earth” or ground
electrical generating plants, etc. The 24VDC applications are mainly in heavy duty
unit and is equipped with four (4) screw-down lead posts. The power terminals are
Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground
will connect to the post labeled “+ve” and the rest to the “-ve”. The GND can be
such as broadcasters, publishers, newspaper operations, brokerage firms and other
This section describes the proper connection of the 12, 24, –48, 125 and
failure. It is also frequently used for computer system backup, management and
The 24V and 125VDC options are particularly useful in the industrial
B4.0 6KQE, 12, 24, –48, 125 and 250VDC INSTALLATION
special power supply in switches with a proven track record.
it blow the fuse in the internal power supply.
operations monitoring equipment.
each lead is securely tightened.
hooked up at the last
(GND).
etc.

12VDC, 24VDC, 125VD or 250VDC products, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more
24VDC, 125VDC or 250VDC dual-source power input is identical to that of the standard single-source DC-powered models.
disconnect device in the building installation supply circuit to the product.
secure the cable to the rack at least 4 inches apart, with the first one located
Operation of Magnum 6KQE Switches with the optional -48VDC, 12VDC,
Before connecting live power lines to the Terminal Block of –48VDC,
“+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be
the user may elect to Ground either + or - terminal to suit the customer’s use.
Minimum 18AWG cable for connection to a Centralized DC power source.
When power is applied, the green PWR LED will illuminate.
Please refer to Section 6.0 for troubleshooting
B4.1 UL Requirements for DC-powered units
within 6 inches of the terminal block.
connected to the post labeled “+”.

12VDC, 24VDC, 125VDC and 250VDC models with this Dual-Source option are identical to those listed in the Magnum 6KQE Edge Switches Installation and User Guide,
125VDC and 250VDC Dual-Source power supply are designed for installations where a battery plant is the power source, and where two separate power sources are utilized in
The functionality of the Magnum 6KQE Switch -48VDC, 12VDC, 24VDC,
With the exception of the dual DC input power connections and the power
supply, all specifications and configuration options for the Magnum 6KQE -48VDC,
125VDC and 250VDC Dual-Source Option units are identical to the AC-powered models. Refer to the main sections of this Installation and User Guide for a detailed
Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-125V)
Power Supply (Internal, 250VDC Dual-Source, model # Dual-Src-250V)
The 6KQE-Switch models with the internal -48VDC, 12VDC, 24VDC,
Power Supply (Internal, 12VDC Dual-Source, model # Dual-Src-12V)
Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)
APPENDIX C: Internal DC Dual-Source Power Input Option
order to increase operational uptime and to simplify maintenance.
C2.0 MAGNUM 6KQE, with DC Dual-Source option
including Appendix B “Internal DC Power Supply Option”
Power Supply (Internal, -48VDC Dual-Source)
description of the Magnum 6KQE Switches.

b) The Switch unit will not allow power to flow from a higher voltage input to a lower
c) When one correct DC input is present, the Switch will receive power if the other DC
even if one input connection is reversed while the Switch is operating from the other
This section describes the proper connection of the -48VDC, 12VDC, 24VDC,
d) Reverse polarity connections, if they should accidentally occur on either input, will
not damage the Switch or power supply internally (nor will it blow the fuse in the
internal power supply) because of the blocking action of the diodes. This is true
125VDC and 250VDC dual source leads to the power terminal block on the Magnum 6KQE Switch (shown in Figure above)
chassis on each DC power input line. A diode is placed in each of the four input lines
a) The Switch unit can receive power from either input, “A” or “B”. The hub will
normally draw its power from the DC source with the highest voltage at a given
voltage input, i.e. the two DC power sources are not mixed together by the hub.
The Dual-Source DC power option is designed using diodes inside of the
connections with Dual-Source option.
e) The Switch will not receive power (and will not work) when both inputs are
Dual Source Terminal block
input is absent, or even if it is connected with reverse polarity or shorted or
simultaneously absent or are both incorrectly connected.

power from an external source can
applied to either or both of the two
whenever DC power is correctly
(behind the four external power
connection terminals) so that
only flow into the unit. This
allows the unit to operate
grounded.
source.
time.
inputs.

chassis is earth/ground (GND). The Dual Source terminal block for the 12, 24, 48, 125
“+ve” voltage lead from a +ve or –ve power supply must be connected to the
The connection procedure is straightforward. Simply connect the DC leads to
To order the optional Dual-Source power supply factory installed, add “Dual-
negative (A-), and the secondary power terminals as negative (B-), positive (B+). The
customer’s use. Before connecting live power lines to the terminal block,
the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground
(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely
The terminal block is located on the left front of the unit next to the Alarm
ground, so the user may elect to Ground either + or - terminal to suit the
always use a digital voltmeter to measure the output voltage of the power
supply and determine the lead which is more “+ve potential”. The more
terminal block and is equipped with four (4) screw-down lead posts. The primary
Src-xxxV” as a separate line item following the product model.
http://www.garrettcom.com/techsupport/insertion_guides/6kqecg.pdf
See the Configuration Guide on the GCI web site at
terminals are identified as positive (A+),
for additional information.
post labeled “+”.
and 250VDC are the same.
tightened.
Dual-Src-48V
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.