Industrial Field Switchp.1Hardware Installationp.1Magnum 6K8-Seriesp.1User Guidep.1andp.1Installation and User Guidep.2Magnum ™ 6K8-Seriesp.2Hardwarep.2Phone (510) 438-9071p.34.4 Flow-control, IEEE 802.3x Standard................................................. 43p.54.5 Power Budget Calculations for Magnum 6K8-with Fiber Media...... 43p.55.0 Introduction - Magnum 6K8 Industrial Field Switch Port Modules45p.55.2.11a GBIC-LXSC Gigabit fiber multi-mode SC Connector.......... 55p.56.3 Return Material Authorization (RMA) Procedure............................. 57p.56.4 Shipping and Packaging Information................................................. 58p.5APPENDIX A: WARRANTY INFORMATION......................................... 58p.5APPENDIX B : Internal DC Power Supply Options.................................... 58p.5APPENDIX C: Internal DC Dual-Source Power Option............................. 61p.509/05 : Draft of Initial Release, Rev Ap.503/06: Minor update on 10/05 : Initial Release, Rev Ap.5Revisionsp.5THE MAGNUM LINEp.6Overviewp.61.1 Technical Specificationsp.71.0 SPECIFICATIONSp.7Magnum Industrial Field Switch (8 ports max)p.10MODEL DESCRIPTIONp.10wiring, and other hardware features. Refer to our Software user Manual forp.122.1 Inspecting the Package and Productp.122.0 Introductionp.122.2 Product Description - Magnum 6K8-Series (6K8)p.132.2.1a Magnum 6K8-Series, Industrial Field Switchp.14ACTp.16F/Hp.162.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mbp.162 4 6 8 LK LK LK Lp.16ACp.16F/H LK LK LK LKp.162 4 6 8 LK LK LK LKp.16fiberp.162.2.4 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45 and 2@100Mbp.17F/H ACTp.1710/100 LKp.172 6 TX RX TX LK RX LKp.172.2.3 Eight-Port Copper Module, 6K8-RJ45p.17fiber 4@RJ-45 + 2@ 100Mbp.172.2.5 Four-Port 10 Mb and 100Mb mm Fiber ST Modulesp.18F/ ACTp.1910/100 Lp.19TX RX LKp.19F/p.192.2.7 Packet Prioritization, 802.1p QOSp.192.2.6 Gigabit (1000Mbps) port modulesp.19TX LK RXp.19TX RX Lp.192.2.8 Frame Buffering and Flow Controlp.202.2.9 Managed Network Software ( MNS-6K ) for Magnum 6K8-Seriesp.212.3 Features and Benefitsp.222.4 Applicationsp.23PLp.24PL PL PLp.24F/ ACp.2410/1 Lp.242 4 F/ ACp.241 3 10/1 Lp.242 TX T LK R Lp.24GARREp.24Fig. 2.4b-Magnum 6K8 equipped with S-Ring in redundant ring in ap.25CCTVp.25F/ Ap.2510/ Lp.252 4 F/ Ap.251 3 10/ Lp.25AF/ Ap.25AF/ AF/p.25outdoor Traffic applicationp.25GARRp.25Magnum 6K8 Industrial Field switch in a Power Substations applicationsp.263.1 Locating Magnum 6K8-Series Switchesp.273.0 Installationp.27
Page 1 of the GarrettCom 6K8 user manual — and
Page 1 · click to enlarge
Page 1
GarrettCom 6K8 — Industrial Field Switch diagram (page 1)
Fig. 1 · Industrial Field Switch

Industrial Field Switch

Hardware Installation

Magnum 6K8-Series

User Guide

GarrettCom 6K8 — Industrial Field Switch diagram (page 1)
Fig. 2 · Industrial Field Switch

and

GarrettCom 6K8 — and diagram (page 1)
Fig. 3 · and
Page 2 of the GarrettCom 6K8 user manual — Hardware
Page 2 · click to enlarge
Page 2

serviceable parts. Attempted service by unauthorized personnel shall render all

Copyright © 2006 GarrettCom, Inc. All rights reserved. No part of this publication may

Magnum 6K8-Series Industrial Field Switch Installation & User Guide (03/06)

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a

warranties null and void. If problems are experienced with Magnum 6K8-

Series Switch products, consult Section 6, Troubleshootings, of this User

be reproduced without prior written permission from GarrettCom, Inc.

Installation and User Guide

Magnum ™ 6K8-Series

Industrial Field Switch

UL is a registered trademark of Underwriters Laboratories

Part #84-00160 (Rev. A)

Hardware

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

registered trademark of GarrettCom, Inc.

Printed in the United States of America.

Guide.

Trademarks

Page 3 of the GarrettCom 6K8 user manual — Phone (510) 438-9071
Page 3 · click to enlarge
Page 3

This equipment generates, uses and can radiate frequency energy and if not

installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested and

found to comply with the limits for a Class A computing device in accordance with the

specifications in Subpart J of Part 15 of FCC rules, which are designed to provide

reasonable protection against such interference when operated in a commercial

environment. Operation of this equipment in a residential area is likely to cause

interference, in which case the user, at his own expense, will be required to take

Magnum 6K8-Series Industrial Field Switch Installation & User Guide (03/06)

Please use the mailing address, phone and fax numbers and email address listed below:

Cet appareil respecte toutes les exigences du Réglement sur le matériel du

This Class A digital apparatus meets all requirements of the Canadian

Radio Frequency Interference Statement

Websitehttp://www.GarrettCom.com

Radio Frequency Interference Statement

email support@garrettcom.com

whatever measures may be required to correct the interference.

47823 Westinghouse Dr. Fremont, CA 94539-7437

GarrettCom, Inc.

Phone (510) 438-9071

Interference-Causing Equipment Regulations.

Canada. Cet appareil est Classe A..

Show 4 more labels / short text on this page
Federal Communications Commission · Fax (510) 438-9072 · Canadian Emission · Contacting GarrettCom, Inc
Page 4 of the GarrettCom 6K8 user manual — Phone (510) 438-9071
Page 4 · click to enlarge
Page 4
Page 4 of the GarrettCom 6K8 user manual — Phone (510) 438-9071
Page 5 of the GarrettCom 6K8 user manual — 09/05 : Draft of Initial Release, Rev A
Page 5 · click to enlarge
Page 5

4.4 Flow-control, IEEE 802.3x Standard 43

4.5 Power Budget Calculations for Magnum 6K8-with Fiber Media...... 43

5.0 Introduction - Magnum 6K8 Industrial Field Switch Port Modules45

5.1 Inspecting the Package and Product .................................................. 45

5.2 6KPMV Module Description 45 5.2.1 6KP6-RJMST, FX-ST “twist lock” Combo Module 46 5.2.1a 6KP6-RJ10ST, mm FX-ST “twist lock” Combo Module 46 5.2.1b 6KP4-F10ST, multi-mode FX-ST “twist lock” Module 47 5.2.1c 6KP4-FLSTFX,multi-mode FX-ST “twist lock” Module 47 5.2.2. 6KP6-RJMSC multi-mode FX-SC “snap-in” Fiber connector 48 5.2.3 6KP6-RJSSC single-mode FX-SC-type, “snap-in” connector... 48 5.2.4 6KP6-RJSSCL single-mode FX-SC-type, “snap-in” connector 49 5.2.4a 6KP6-RJ10ST multi-mode FL-ST-type, “twist-lock” connector49 5.2.5 6KP8-MTRJ, small-Form-factor 50 5.2.5a 6KP6-MT10ST, MTRJ Small-Form-Factor ST-Fiber port 50 5.2.6 6KP8-45MT, MTRJ Small-Form-Factor 51 5.2.7 6KP8-MLC, Small-Form Factor 51 5.2.8 6KP8-45LC, LC small-form factor 52 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port 52 5.2.10 6KP8-45-2MT, multi-mode FX , MTRJ Small-Form-Factor 53 5.2.10a 6KP8-45-2LC, single-mode FX , LC Small-Form-Factor 53 5.2.11 GBIC-SXSC Gigabit fiber(1000Mb)multi-mode SC Connector54

5.2.11a GBIC-LXSC Gigabit fiber multi-mode SC Connector 55

6.0 TROUBLESHOOTING ...................................................................... 56

6.1 Before Calling for Assistance ............................................................ 56

6.2 When Calling for Assistance ............................................................. 57

6.3 Return Material Authorization (RMA) Procedure............................. 57

6.4 Shipping and Packaging Information................................................. 58

APPENDIX A: WARRANTY INFORMATION......................................... 58

APPENDIX B : Internal DC Power Supply Options.................................... 58

APPENDIX C: Internal DC Dual-Source Power Option............................. 61

Magnum 6K8-Series Industrial Field Switch Installation & User Guide (03/06)

09/05 : Draft of Initial Release, Rev A

03/06: Minor update on 10/05 : Initial Release, Rev A

Revisions

Page 6 of the GarrettCom 6K8 user manual — Overview
Page 6 · click to enlarge
Page 6

GarrettCom, Inc. offers the premium-quality Magnum™ line of Ethernet LAN

configurability. Magnum products are designed for use in demanding Carrier

connectivity products with industry-standard functionality and built-in fiber

Class, Industrial Grade and OEM applications where reliability is a primary

6K-Series Managed Fiber Switches, MODULAR- Gigabit, 100 and 10 Mbps, fiber and copper ports, mix-and match. Features SFF fiber and DC power in 1U units.

Converter and convenient switches, 4 port 10/100 compact & economical switcehs and

4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto- negotiating full switching performance.

Transceivers, 10Mb series Mini-Transceivers and Coax Models Mar., 06

POE POWER SOURCE SWITCH, 4 10/100 Power source switch to provide power,

Edge SwitcHEs, Economical 6 port 10/100 and a combo of fiber+copper, provide an

Quad-Series Fiber Switches, MODULAR- 100 & 10Mbps, fiber and copper ports,

3-port (2 10/100 and one fiber 10 or 100Mbps) converter switches for temperature uncontrolled locations.

“Outdoor” Ethernet Switch, for temperature uncontrolled locations

"Designed and Manufactured in the USA"

Repeater Port Modules (RPMs), 6 types for Ethernet media

Bridge Port Modules (BPMs), 4 types, for segment isolation

THE MAGNUM LINE

6 10/100 and 2 100Mb fiber ports, can be connected in strings Mixed-Media Fiber Hub, 16-port Stackable,10/100 auto-sensing

Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing

mixed-speed and mixed-media types, full switching performance.

8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series

All media combinations, incl. fiber ST, SC, mm., single mode

Stackable Concentrators, SNMP optional, 13-Ports

effective solution for Industrial and outdoor environment.

10Mb series(12/24 ports RJ-45), w/ optional port modules Personal Switches, 10/100Mb

The “X-line” of configurable MiXed Media products:

Overview

8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb

Mini-Concentrators, 7 Ports, Repeaters, 2-Ports

8-port, with two switched ports (1 fiber built in) Personal Hubs, 10Mb series

Stackable Hubs, SNMP Optional

data, and voice through RJ-45 ports.

consideration.

Ethernet connectivity products

Page 7 of the GarrettCom 6K8 user manual — 1.1 Technical Specifications
Page 7 · click to enlarge
Page 7
Switching Processing TypeStore and Forward with IEEE 802.3x full-

100BASE-FX, full-duplex, single-mode - 20.0 km (66K8-Series ft)

Fiber Port, ST-type (twist-lock):Fiber multi-mode, 10Mb 10BASE-FL

100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft)

Fiber Port, MTRJ-type (plug-in):SFF Fiber multi-mode100BASE-FX

Fiber Port, ST-type (twist-lock)Fiber optic m.-mode, 100BASE-FX

Unshielded twisted pair - 100 m (328 ft)

10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)

10BASE-FL single-mode fiber optic - 10 km (32,810 ft)

10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)

100BASE-TX (CAT 5 UTP) - 100 m (328 ft)

100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft)

Fiber Port, SC-type (snap-in):Fiber optic multi-mode, 100BASE-FX

Packet buffer size240KB for 10/100 and 120KB for 1000Mb

100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft)

100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)

1000BASE-T (CAT5e or higher is recommended) - 100 m (328 ft) 1000BASE-SX, full-duplex, multi-mode(62.5µm cable) - 220m 1000BASE-SX, full-duplex, multi-mode(50µm cable) - 550m 1000BASE-LX, full-duplex, single-mode(62.5µm cable) -5Km Fiber Multi-mode connector types supported:

Shielded twisted pair - 150 m (492 ft)

Shielded twisted pair - 150 m (492 ft)

Address Table Capacity4K node, self-learning with address aging

15 µs + packet time (10 to 10 Mbps, and 10 to 100Mbps)

IEEE 802.3z1000BASE-TX Ethernet (Auto-Negotiation)

Maximum Standard Gigabit Ethernet Segment Lengths:

Maximum Standard Fast Ethernet Segment Lengths:

Data Rate10Mbps,100Mbps and 1000Mbps

Fiber Port, 1000BASE-FX, GBIC modules

Gigabit Ethernet(1000Mb)1, 488,000 pps

Network Standards and Compliance, hardware

Ethernet V1.0/V2.0 IEEE 802.310BASE-T,

Maximum 10 Mbps Ethernet Segment Lengths

duplex flow -control, non-blocking

Latency5 µ s + packet time (100 to 100Mbps)
IEEE 802.3u100Base-TX, 100BASE-FX
Fast Ethernet(100Mb)148,800 pps
IEEE 802.3ab1000BASE-TX Ethernet
IEEE 802.1dSpanning tree protocol

Filtering / Forwarding Rate:

Ethernet(10Mb):14,880 pps

IEEE 802.1pPriority protocol
IEEE 802.1qVLAN Tagging
IEEE 802.3xFlow Control

1.1 Technical Specifications

1.0 SPECIFICATIONS

Performance

Page 8 of the GarrettCom 6K8 user manual — 1.1 Technical Specifications
Page 8 · click to enlarge
Page 8

used as heat-sink. designed for vertical mounting, no fans

-40° to 140° F (-40° to 60°C) for UL60950 and Component Parts rating

-60° to 205° F (-50° to 95°C) for IEC 60068 Type Test short term rating

Cooling methodConvection, fully –enclosed elongated dual-cavity case

DB-9 for RS-232 “null-modem” cable (sometimes called an X-modem cable)

Fiber Port, LC-type Fiber optic SFF single-mode, 100BASE-FX

One NC indicating internal power, one NC software controllable

Conformal Coating (humidity protection) option: Request quote

Fiber Port, SC-typeFiber optic single-mode, 100BASE-FX
AC Power ConnectorIEC-type, male recessed at rear of chassis,
Ambient Relative Humidity5% to 95% (non-condensing)

25 watts typical (for a fully loaded fiber model) 15 watts typical (for a 8-port copper only model)

LEDsPer Port (one set at the port, one set on rear top)
Storage Temperature-60 ° to 210 ° F (-50 ° to 100 ° C)
Dimensions9.8 in. H x 5.90 in. W x 3.70 in. D

24.9 cm H x 15.0 cm W x 9.4 cm D

LKSteady ON when media link is operational

Enclosure: Rugged High strength sheet metal.

Fiber Port, 1000BASE-FX, GBIC modules

Altitude-200 to 13,000 ft. (-60 to 4000m)
Input Voltage100 to 240 VAC (auto-ranging)

OFF = Half-Duplex Mode

Input Frequency47 to 63 Hz (auto-ranging)
FDX/HDXON = Full-Duplex Mode
ACTON with receiver port activity

Fiber Single-mode connector types:

100/10ON = 100Mbps speed OFF = 10 Mbps
Weight2.1 lbs. (0.95 kg)

Ambient Temperature:

Power Consumption:

Show 5 more labels / short text on this page
Management Console connector · Operating Environment · Power Supply (Internal) · Alarm Relay Contacts · Packaging
Page 9 of the GarrettCom 6K8 user manual — 1.1 Technical Specifications
Page 9 · click to enlarge
Page 9

including Dual Source options (for continuity of operation when either of the

The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45

ports., and eliminate the use of cross-over cable between the devices. Also

port-specific user settings (such as FDX or HDX, copper 10/100 speed) can

C sheltered locations where neither temperature nor humidity are controlled.

IEEE 61850 EMC and Operating Conditions, class C for Electric Power

The equipment needs to be protected against solar radiation, rainfall, other

precipitations and wind. UL has not approved these products for Annex-T

WarrantyThree years, per UL 60950 temperature rating Made in USA

For DC internal power supplies at –48VDC, 24VDC and 125VDC,

IEEE P1613 Environmental Standard for Electric Power Substations

Vertical mounting only Suitable for wall or DIN-Rail mounting

Power Consumptionsame as for AC models, see above

DC input sources are interrupted), see Appendices B and C.

-48VDC Power Input Voltage-36 to -70 VDC

NEMA TS-2 and TEES for traffic control equipment

125VDC Power Input Voltage : 88 to 300VDC 5VDC Power Input Voltage : (+) or (-) 5% Std. Terminal Block : “ -, GND, + ”

24VDC Power Input Voltage18 to 36VDC

Email sales@GarrettCom.com for details.

Emissions meet FCC Part 15 Class A

be fixed using software commands.

Per-port MDI or MDIX on RJ-45

UL listed (UL60950), cU, CE

DC Power Supply (Options)

outdoor use.

Mountings:

Agency Approvals · Magnum 6K8 · Substations

Page 10 of the GarrettCom 6K8 user manual — MODEL DESCRIPTION
Page 10 · click to enlarge
Page 10
Magnum 6K8 -5VDCSame as 6K8 except the power input is regulated 5VDC & fused

Each Magnum 6K8 base unit has one port module slot which can be equipped with

and 120KB for 1000Mb. For licensed managed networks software (MNS-6K and S-ring),

processing, self-learning 4K-node address table, large 240KB packet buffers for 10/100

one of the following single or multi-mode fiber, copper, 1000, 100 or 10Mbps modules.

6KP8V-SLC SFF Fiber module, with 8x100Mbps single-mode FX LC connectors

6KP4V-FXSC “2+2” 100Mb Fiber module, with 4x100Mb 2km FX SC connectors

Worldwide AC power. May be configured with a selection of 10/100/1000 fiber and

6KP4V-FXST “2+2” 100Mb Fiber module, with 4x100Mb 2km FX ST connectors

6KP4V-FLSTFX “2+2” ST Fiber module, with 2x100Mb & 2x10Mb ports, 2km 6KP8V-45-2MT “6+2” module, with 6xRJ-45 ports and 2x100Mb 2km FX MTRJ 6KP8V-45-2SLC “6+2” module, with 6xRJ-45 ports and 2x100Mb s.m 15km FX LC 6KP8V-45MT “4+4” module, with 4xRJ-45 ports and 4x2km mm FX MTRJ

6KP6V-RJMST “4+2” module, with 4xRJ-45 ports and 2x2km mm FX SC 6KP6V-RJMSC “4+2” module, with 4xRJ-45 ports and 2x2km mm FX ST 6KP6V-RJSSC “4+2” module, with 4xRJ-45 ports and 2x20km single.mode FX SC 6KP6V-RJSSCL “4+2” module, with 4xRJ-45 ports and 2x40km single mode FX SC 6KP6V-MT10ST “4+2” module, with 4xMTRJports and 2x10Mb 2km FL ST 6KP6V-RJ10ST “4+2” module, with 4xRJ-45 ports and 2x10Mb 2km FL ST

Magnum Industrial Field Switch (8 ports max)

copper port connector types, 8 total ports max. for 10/100Mbps or 2 ports maxm for

filtering and forwarding across all ports, 802.3x flow control, 802.1p priority packet

6KP4V-F10ST “2+2” 10Mb Fiber module, with 4x10Mb 2km FL ST connectors

6KP8V-45MLC “4+4” module, with 4xRJ-45 ports and 4x2km mm LC connectors 6KP8V-45SLC “4+4” module, with 4xRJ-45 ports and 4x2km single mode LC

Magnum 6K8 -Managed Industrial Field Switch, base unit for vertical mounting.

Gigabit ports. Two metal brackets for vertical wall or panel mounting. Wire speed

6KP8V-RJ45 TP Module, with 8x10/100Mbps auto-negotiating RJ-45 ports

6KP8V-MTRJ SFF Fiber module, with 8x100Mb mm FX MT-RJ connectors

6KP8V-MLC SFF Fiber module, with 8x100Mbps mm FX LC connectors

Magnum 6K8-48VDCSame as 6K8 except the power input is –48VDC
Magnum 6K8-125VDCSame as 6K8 except the power input is 125VDC
Magnum 6K8 -24VDCSame as 6K8 except the power input is 24VDC

MODEL DESCRIPTION

1.2 Ordering Information

Magnum 6K8 Port Modules

See separate data sheets.

Configuration Options:

Page 11 of the GarrettCom 6K8 user manual — Magnum Industrial Field Switch (8 ports max)
Page 11 · click to enlarge
Page 11

6KP5V-G4RJ “G+4” module, with one GBIC receptacle for one user selectable GBIC

6KP3V-G2SC “G+2” module, with one GBIC receptacle for one user selectable GBIC

receptacle for a user selectable GBIC transceiver module (see below).

GBIC-SXSC One 1000BASE-SX port with 850nm multi mode SC fiber connector

GBIC-ZXSC40 One 1000BASE-ZX port with 1550nm, single mode SC(40km) fiber

GBIC-ZXSC70 One 1000BASE-ZX port with 1550nm, single mode SC(70km) fiber

CONSOLE CBL Industry standard serial cable, DB-9 connectors for RS-232 “ null-

modem “ connection (sometimes called an X-modem cable), used to connect a PC or a

CONSOLE USB Industry standard serial cable, DB-9 connectors for RS-232 “ null-

DIN-RAIL-VRM DIN-Rail holder for a secure vertical mount of a 6K8-Series unit,

GBPMV-2OTX Two-port Gigabit module for 6K8-Series Switches, with two GBIC

GBIC-LXSC10 One 1000BASE- LX/LH port with 1310nm single mode SC(10km)

GBIC-LXSC25 One 1000BASE- LX/LH port with 1310nm single mode SC(25km)

GBPMV-COTX One slot Gigabit module for 6K8-Series Switches, with one GBIC

modem “ connection (sometimes called an X-modem cable) to connect to a managed

transceiver (see below) and 2 100Mb 2km FX SC fiber ports.

receptacles for user selectable GBIC transceivers (see below).

transceiver (see below) with 4 fixed 10/100 RJ-45 ports.

GarrettCom, Inc. reserves the right to change specifications, performance

GBIC-TP One 802.3ab 1000BASE-T port, RJ-45 connector

GBIC(1000Mb) Transceiver options for Mangum 6K8-Series

with screws to attach to metal mounting brackets of the 6K8 case.

characteristics and/or model offerings without notice.

character terminal to the Management port.

switch, and a USB port to connect to a PC

Show 4 more labels / short text on this page
fiber connector · fiber connector · connector · connector
Page 12 of the GarrettCom 6K8 user manual — 2.0 Introduction
Page 12 · click to enlarge
Page 12

In the event there are items missing or damaged, contact the party from whom

product; notify the carrier of any damage that you believe occurred during shipment or

delivery. Inspect the contents of this package for any signs of damage and ensure that

Remove the items from the shipping container. Be sure to keep the shipping

shipping container if possible. Refer to Section 6, Troubleshooting, for specific return

wiring, and other hardware features. Refer to our Software user Manual for

Examine the shipping container for obvious damage prior to installing this

container should you need to re-ship the unit at a later date. To validate the product

information about the Magnum 6K8 and provides help for Network installation,

management software features and configurations (e.g. VLANS, RSTP, SNMP,

www.garrettcom.com/techsupport/software/userguides/6kseries_softugrel3.pdf

1 Set of two metal vertical mounting brackets, with screws to the case

you purchased the product. If the unit needs to be returned, please use the original

warranty, please complete and return the enclosed Product Registration Card to

(configured with user-selected port module options installed)

1 AC Power Cord (U.S. and other 115 VAC only) if AC version

1 Magnum 6K8-Series Industrial Field Switch, base unit

1 Installation and User Guide (this manual)

2.1 Inspecting the Package and Product

RADIUS, TACACS etc.) using this URL-

1 Product Registration Card

This package should contain:

GarrettCom, Inc. as soon as possible.

the items listed below are included.

2.0 Introduction

procedures.

Page 13 of the GarrettCom 6K8 user manual — 2.2 Product Description - Magnum 6K8-Series (6K8)
Page 13 · click to enlarge
Page 13

combination of 10Mb, 100Mb and 1000Mb speed ports with comprehensive management

and 10/100 Mb auto-negotiating RJ-45 ports. Standard GBIC ports can be configured for

a variety of Gigabit cabling types and distances. For details about module configurations

metal case into a heat sink as well as a shield for reducing electrical noise and providing

The Magnum 6K8-Series, Industrial Field Switch is the smallest member of

ports. It is specially designed to meet industrial, power substation, and outdoor Ethernet

temperature rating of -40˚C to 60˚C calculated by the UL Component Parts method, or -

50˚C to 95˚C by the IEC 60068 calculated by the Type Test method. With various Power

The extremely versatile options of various port modules offer all fiber media

the Managed 6K-Switch family. It is equipped with one module slot configurable to 8-

specifications while fulfilling the needs of hardened applications. 6K8-Series managed

software in a compact industrial-grade package. The combination of multiple possible

DIN-Rail mounting, the hardened Magnum 6K8-Series is a “multi-purpose” Industrial

possibilities including small form factor (all connector types, multi- and single-mode)

Supply options, such as all popular DC power input types, worldwide AC power and

please go to http://www.garrettcom.com/techsupport/insertion_guides/6k8cg.pdf

Advanced thermal design techniques (patent pending) transform the tough

physical protection. The unique design features an elongated dual-cavity shape for

field switches provide modularity of fiber and copper ports. They come with a

2.2 Product Description - Magnum 6K8-Series (6K8)

Setting a new standard for Industrial

options, a hardened enclosure, and

managed Field Switch providing a

accommodated with an extended

makes the Magnum 6K8 a very

powerful, effective and reliable

secure solution for many needs.

and Carrier Class applications,

heavy duty Ethernet Switch

Ethernet Switch.

configurations, multiple power · MNS-6K management software · requirements are readily

Page 14 of the GarrettCom 6K8 user manual — 2.2.1a Magnum 6K8-Series, Industrial Field Switch
Page 14 · click to enlarge
Page 14

use as backbone switches where a mix of bursty data traffic and priority streaming traffic

topologies, Spanning Tree Protocol, Rapid Spanning Tree Protocol, Link-Loss-Learn and

Ring datasheets for additional details on the comprehensive set of software programs and

achieve high EMI noise immunity and provide an un-matched IP53 physical protection

High performance features include non-blocking speed on all ports and 802.1p

QoS Traffic Prioritization. Magnum 6K8-Series switches are “plug-and-play” ready for

allow this Industrial Field Switch to qualify for a sub-standard managed switch to meet

S-Ring (ring only) are available. See the Managed Networks Software (MNS-6K) and S-

The wide selections of port modules are key to the flexibility and adaptability.

convection cooling (no fans), the Magnum 6K8 easily qualifies for use in transportation

optimal cooling of internal components without any ventilation openings. This sealed-

Security with control via secure Web and command line interface (CLI). Loaded with

worldwide. Internal DC power supplies are optional. All DC power input types (24V,

The Magnum 6K8-Series is primarily designed for use in vertical mount applications.

Magnum 6K8-Series Fiber Switches are provided with LAN management

secure features like- Radius server (802.1x), TACACS+, SNMPV3 and Port Security

Magnum 6K8-Series, Industrial Field Switches have heavy duty

case design enables the unit to operate in temperature un-controlled environments,

the Industrial expectation. For high availability, Redundant LANs using ring/mesh

metal cases and auto-ranging power supplies for operation with standard AC power

Alarm Relay contacts provided on each Magnum 6K8-Series Switch are

monitored via the hardware and software providing a loss of power signal and user-

Equipped with multi-media fiber/copper solutions, multiple speed 10/100/1000Mb

software including SNMP, Tag and Port-based VLANs, IGMP Snooping and Port

support, rich MNS-6K management features, hardware and software alarms and

defined software events through traps. See Section 3.5 for details.

for VoIP and audio/video “Triple Play” applications are present.

2.2.1a Magnum 6K8-Series, Industrial Field Switch

48V, 125V) are supported, and dual source input is optional.

http://www.garrettcom.com/Pictorial/6k8_pictorial.pdf

rating against dust, dirt, insects, and liquid spills.

options.

Page 15 of the GarrettCom 6K8 user manual — 2.2.1a Magnum 6K8-Series, Industrial Field Switch
Page 15 · click to enlarge
Page 15
GarrettCom 6K8 — 2.2.1a Magnum 6K8-Series, Industrial Field Switch diagram (page 15)
Fig. 4 · 2.2.1a Magnum 6K8-Series, Industrial Field Switch
GarrettCom 6K8 — 2.2.1a Magnum 6K8-Series, Industrial Field Switch diagram (page 15)
Fig. 5 · 2.2.1a Magnum 6K8-Series, Industrial Field Switch

The advanced generation of industrial applications requires advanced managed network

one slot defines the Magnum 6K8 Field switches role as an effective Managed Gigabit

through its rich modular structure. The Relay contact for external “ALARM” is another

backbone interconnections, the Magnum 6K8 managed switches are easy to install and

Dual LEDs on the front and Top side help the vertically mounted 6K8 to be monitored

maximum of two Gigabit modules (fiber or copper) to meet any demand of bandwidth

applications, the Magnum 6K8 is a fine solution to meet and satisfy any requirements

additional feature which allows the Magnum 6K8 to monitor the internal power failure

and traffic control systems, power utilities and industrial factory-floors. For the fast

growing demands of video surveillance systems with segments requiring Gigabit

easily. The modular designed Magnum 6K8 Industrial Field switch can support a

media converter Switch that meets any secured Gigabit media requirements.

required applications. In an on-going demand of diversified designed Ethernet

managed and monitored via SNMP or secured Web.

Field switches, should be mounted vertically using

operate with Magnum 6K management firmware.

the vertical mounting brackets which come along

software (MNS-6K), the 6K8 switch can be easily

Supporting dual Gigabit ports (copper or fiber) in

Loaded with versatile and secured management

with the unit or by using the DIN-RAIL-KIT

redundancy, security and gigabit backbone

configurability. The Magnum 6K8 has all

of these, in a very tough and robust metal

The plug-n-play Magnum 6K8 Industrial

support for self-healing ring structures,

case with a wide choice of popular DC

options or industry standard AC internal

temperatures, fiber ports modularity,

(optional) for Din rail mounting.

software, operation at extended

input.

Page 16 of the GarrettCom 6K8 user manual — ACT
Page 16 · click to enlarge
Page 16

ACT

F/H

ACT

F/H

ACT

F/H

ACT

F/H

and controlled via hardware or software trap controls. The options for universal AC and

6K8-MTRJ (to the left) and

6K-MNS Software Manual) for the flexibility to adapt to any FDX or HDX type of Fast

operation” on that port when lit, the F/H LED indicates operation in full-duplex

mode when ON (half-duplex when OFF), and the blinking ACT LED indicates

receiving Activity on the port. A fiber cable must be connected into a SFF port

24V/-48V/125VDC power options offer a widely accepted managed switch with high

In an eight-port SFF fiber port module, all of the fiber ports are of the same

select full- or half-duplex mode per-port through set-up of the software (See Magnum

There are three LED’s per fiber port. The Link (LK) LED indicates “ready for

2.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb

speed (100Mb), mode, and connector type. Models available with Small Form Factor

6K8-MLC or -SLC (below)

and the Link (LK) indicator for that port must be ON (indicating there is a

powered-up device at the other end of the cable) in order for a LK LED to

(SFF) are multi-mode MT-RJ or LC-type connectors, and single-mode LC-type

2 4 6 8 LK LK LK L

2 4 6 8 LK LK LK L

1 3 5 7

Fig.2.2.2 :

provide valid indications of operating conditions on that port.

AC

F/H

AC

F/H

AC

F/H

AC

F/H

ACT

F/H

ACT

F/H

ACT

F/H

ACT

F/H

1 3 5 7

F/H LK

2 4 6 8 LK LK LK LK

The 100Mb fiber eight-port

fiber distance and performance. Using

modules for the Magnum 6K8-Series

normally are set (factory default) to

operate in full-duplex mode for best

the 6K-MNS software, the user may

Ethernet devices).

connectors.

reliability.

ACT

ACT

fiber

F/H

ACT

F/H

ACT

F/H

SFF Fiber Port · Modules,

Page 17 of the GarrettCom 6K8 user manual — ACT
Page 17 · click to enlarge
Page 17

selects a mode and speed to match the device at the other end of the twisted pair cable.

(See Section 4.3 for auto-negotiation and MDIX details). The auto-crossover feature will

port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that port

The four RJ-45 ports operate just like the 8-port copper module with auto-cross

On the model 6K8-RJ45 module, there are four LEDs for each port, two in the

connector and two separate. The LK (Link) LED indicates “ready for operation” on that

speed when OFF (when auto-negotiation is not disabled). The FDX/HDX LED is ON to

Using the 6K8-Series (MNS-6K) management software, the user may disable

auto-negotiation and fix the desired operation of each RJ-45 port. User may select 10Mb

2.2.4 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45 and 2@100Mb

10/100Mb switched RJ-45 ports. The 10/100Mb switched ports normally (as a default setting) are independently N-way auto-negotiating, and auto-crossover(MDIX) for

operation at 10 or 100Mb speed in full- or half-duplex mode, i.e., each independently

when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10 Mb

GarrettCom 6K8 — 2.2.4 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45 and 2@100Mb diagram (page 17)
Fig. 6 · 2.2.4 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45…

F/H ACT

The combo six-port modules are combinations of copper and fiber media, available as

four 10/100 switched RJ-45 copper ports and two 100Mb switched multi-mode fiber in

order for a LK LED to provide valid indications of operating conditions on that port.

or 100Mb speed and full- or half-duplex mode per-port as per user requirement. (See

10/100 LK

2 6 TX RX TX LK RX LK

either ST, SC, single mode SC or Long Reach SC ports. For port numbering, ports

automatically determine the other side of connection to make the connection, and

The 6K8-Series’s 8-port Copper port module, model 6K8-RJ45, provides eight

1 3 5 7

1,3,5,7 are copper, ports 2 and 6 are fiber, and ports 4 and 8 are not present.

ACT

F/H

2.2.3 Eight-Port Copper Module, 6K8-RJ45

Magnum MNS-6K Software Manual for details info.).

ACT

F/H

fiber 4@RJ-45 + 2@ 100Mb

eliminate the need of cross-over cable.

10/100 LK

F/H ACT

2 6 TX RX TX LK RX LK

1 3 5 7

cable must be connected into

must be ON (indicating there

is a powered-up device at the

duplex mode. A twisted pair

an RJ-45 port and the Link

(LK) indicator for that port

and OFF to indicate half-

other end of the cable) in

ACT

F/H

ACT

F/H

ST or SC · indicate full-duplex operation

Page 18 of the GarrettCom 6K8 user manual — 2.2.5 Four-Port 10 Mb and 100Mb mm Fiber ST Modules
Page 18 · click to enlarge
Page 18

(MDIX) features to eliminate the use of cross-over cables. The two fiber ports operate at

On Magnum “4+2” Combo modules, there are four LED’s for each RJ-45 port,

port LEDs indicate status the same way as described for the SFF fiber modules in Section

fiber modules except for the 10Mb speed. For port numbering, ports 1, 2, 5, 6 are present,

100Mbps full-duplex (default). User mode control per port through the MNS software is

4@ MTRJ 100Mb mm SFF fiber and

4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber and the RJ-45 half of

any other device with a 10Mb fiber Ethernet port. The default setting of the 100Mb fiber

which indicate status as described for the 6K8-RJ45 in Section 2.2.3 above. The fiber

The Magnum Combo six-

port modules are also available with

2@10Mb fiber mm ST ports, or 4@

the module is as described for those port types above. For detailed information about

The 4-port @10Mb ST fiber modules behave the same as the 4@100Mb ST

The default setup on the 10Mb fiber module is half-duplex, which allows the

Magnum 6K8-Series Switch to connect to any 10Mb hub or media converter or almost

The fiber ports support fiber-cabling distances according to the 10BASE-FL

and 100BASE-FX standards, i.e., 2km distance for multi-mode fiber. (Single-mode for

2.2.2 above. Color-coding on the panel of the module shows which LEDs belong to

RJ45 10/100 copper and 2@10Mb

module is full duplex. User mode-control per port through the MNS “port settings”

ports 3, 4. 7, 8 are not present. There is also a similar 100Mb fiber SC module.

fiber mm ST ports. The

2.2.5 Four-Port 10 Mb and 100Mb mm Fiber ST Modules

up to greater distance may be available as a special order, request quote).

GarrettCom 6K8 — 2.2.5 Four-Port 10 Mb and 100Mb mm Fiber ST Modules diagram (page 18)
Fig. 7 · 2.2.5 Four-Port 10 Mb and 100Mb mm Fiber ST Modules

10Mb mm ST fiber half of the module, see Section 2.2.5.

software is the same as the other 6K8-Series modules.

GarrettCom 6K8 — 2.2.5 Four-Port 10 Mb and 100Mb mm Fiber ST Modules diagram (page 18)
Fig. 8 · 2.2.5 Four-Port 10 Mb and 100Mb mm Fiber ST Modules

which port.

also the same.

Page 19 of the GarrettCom 6K8 user manual — ACT
Page 19 · click to enlarge
Page 19

one or two Gigabit ports can be configured in one modular slot. The Gigabit modules are

or the 6KP3V-G2SC (single Gigabit+2 100Mb fiber ports) as shown below in the figure.

F/ ACT

duplex mode at any time. The Gigabit fiber port has LEDs that indicate LK (Link status)

The Magnum 6K8-Series offers a wide range of optional Gigabit modules and

the two port GBPMV-2OTX , the 6KP5V-G4RJ (single Gigabit+4 10/100 RJ-45 ports)

1@ 1000Mb Fiber SC + 2@ 100Mb SC 1@ 1000Mb Fiber SC + 4@10/ 100Mb

mode (550m) and single-mode (10, 25, 40, 70) km fiber options. Gigabit copper is also

performance. The 1000Mbps SC fiber-optic module on the Gigabit -SX and Gigabit-LX

There are two LEDs mounted on each Gigabit port module. The Gigabit fiber

users from datagram paths that go all across a network. As a LAN device, the Magnum

6K8-Series can do its part to prevent any QOS degradation while it is handling Ethernet

10/100 L

GBICs to provide Gigabit media flexibility. GBIC models are available for both multi-

port is by default configured to AUTO mode, and can be fixed at 1000Mbps speed full-

The 6K8-Series Modules provide a GBIC opening for insertion of industry-standard

Quality of Service means providing consistent predictable data delivery to

1 3 5 7

The 1000Mb Gigabit fiber-port modules on the Magnum 6K8-Series are

normally set (factory default) to operate at AUTO mode for best fiber distance and

used for Magnum 6K8, please check section5.2, 6KPM Module Description.

transceivers are compatible with the IEEE 802.3z Gigabit standards.

TX RX LK

ACT

F/

and ACT (receiving activity) on that port when lit.

2.2.7 Packet Prioritization, 802.1p QOS

2.2.6 Gigabit (1000Mbps) port modules

available with new models appearing often.

TX LK RX

traffic through its ports and buffers.

ACT

F/

TX RX L

TX RX LK

ACT

ACT

F/

F/

Page 20 of the GarrettCom 6K8 user manual — 2.2.8 Frame Buffering and Flow Control
Page 20 · click to enlarge
Page 20

priority tagged packets according to the 802.1p standard. In addition to hardware support

for QOS, the MNS software (Rel3) supports two priority queues that can be shared across

the eight levels of defined packet priorities for application-specific priority control by the

Magnum 6K8-Series’s are store-and-forward switches. Each frame (or packet)

CRC, i.e., are good packets. This eliminates the propagation of bad packets, enabling all

"express") impose minimal frame latency, they will also permit bad frames to propagate

out to the Ethernet segments connected. The "cut-through" technique permits collision

fragment frames (which are a result of late collisions) to be forwarded which add to the

network traffic. Since there is no way to filter frames with a bad CRC (the entire frame

collisions and bad packets are more likely when traffic is heavy, the result of store-and-

forward operation is that more bandwidth is available for good packets when the traffic

When the Magnum 6K8-Series Switch detects that its free buffer queue space

is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the

Another feature implemented in Magnum 6K8-Series Switches is a collision-based flow-

traffic. The flow control option is user configurable (enable/disable) through the setport

control mechanism (when operating at half-duplex only). When the Switch detects that

is loaded into the Switch’s memory and inspected before forwarding can occur. This

technique ensures that all forwarded frames are of a valid length and have the correct

dropping packets. Then, normal packet buffering and processing resumes. This flow-

its free buffer queue space is low, the Switch prevents more frames from entering by

forcing a collision signal on all receiving half-duplex ports in order to stop incoming

standard and fulfills its role in support of QOS, giving packet processing priority to

must be present in order for CRC to be calculated), the result of indiscriminate cut-

through forwarding is greater traffic congestion, especially at peak activity. Since

control sequence occurs in a fraction of a second and is transparent to an observer.

The Magnum 6K8-Series switching hardware supports the IEEE 802.1p

While other switching technologies (such as "cut-through" or

devices sending packets to cause “flow control”. This tells the sending devices to

temporarily stop sending traffic, which allows a traffic catch-up to occur without

command of MSN-6K software as per the requirement of a network.

of the available bandwidth to be used for valid information.

2.2.8 Frame Buffering and Flow Control

user through software configuration settings.

load is greatest.

Page 21 of the GarrettCom 6K8 user manual — 2.2.9 Managed Network Software ( MNS-6K ) for Magnum 6K8-Series
Page 21 · click to enlarge
Page 21

Magnum 6K8-Series comes with licensed MNS-6K Firmware (Rel 3.2), which

allows the configuration of the Magnum 6Ks as a Managed Switch and also allows other

All MNS-6K software information, including new releases and upgrades related to MNS-

www.GarrettCom.com/techsupport/index.htm#software and look for Magnum

2.2.9 Managed Network Software ( MNS-6K ) for Magnum 6K8-Series

Software enabled features. For additional information about MNS-6K, see the Magnum

6K8-Series MNS Software User guide in pdf format, a separate document normally

Magnum MNS-6K Operator Training – This interactive training software

For upgrading the Magnum 6K8 Switch to its latest Magnum 6K-

http://www.garrettcom.com/techsupport/software/upgrade_mns6k.pdf

instructs on all the basic and advanced information about the Magnum MNS-6K

or FTP client program at ftp.GarrettCom.com. Use the following to log in.

Alternatively, for documentation and latest information, or needed

Finally, please email: support@GarrettCom.com for further information.

6K software can be accessed and download from GarrettCom’s FTP site.

Firmware, follow through the steps and instruction provided on -

accessed via your web-browser, at ftp://ftp.garrettcom.com/

management software and is a useful tool for the first time user.

GarrettCom proprietary MIBs for SNMP- please go to

passwordm6kuser
userm6kuser

MNS-6K info.

Page 22 of the GarrettCom 6K8 user manual — 2.3 Features and Benefits
Page 22 · click to enlarge
Page 22

They are typically used in LAN traffic centers with 16 100Mb or 8+2 Gigabit ports for

S-Ring and Link-Loss-Learn provide reliable fast recovery of a fault in ring topology.

provides for this with heavy-duty components. The ambient temperature dual-rating is

TACACS+. MNS-6K software is factory installed, supported and updated via Internet

Magnum 6K8-Series Switches provide non-blocking (all ports can run at full speed at

The Magnum 6K8-Series switching hardware supports QoS, giving packet processing

Magnum 6K8-Series Industrial Field Switches are designed to naturally include fiber

ports, and support mixes of multi-mode and single-mode; 10 Mb, 100Mb and 1000Mb

„ Relay Contacts for monitoring internal power and user-defined software events

signal loss of power internally. The other is software controllable and will signal user-

defined software event traps such as a security violation or an S-Ring fault condition.

Ethernet signal and power cables attach in the bottom. Two sets of status LEDs are on

the switch, one set viewable at the port connector and one set viewable from the front.

applications, models with –48VDC or 24VDC or 125VDC are available. Dual Source

key) multi-level QoS, Port- and tag-based VLANs, GVRP, IGMP Snooping, SNMPc

GUI support; Event Log; SNTP client for time-of-day; BootP and DHCP client for IP

once) performance with standard Managed Networks Software (MNS-6K) included.

priority to priority tagged packets according to the IEEE 802.1p standard. For port-

Vertical mounting brackets are included. DIN-Rail mounting hardware is optional.

TFTP, FTP support, Spanning Tree Protocol, Link-Loss-Learn, S-Ring (with license

„ S-Ring and Link Loss Learn for reliable high availability using ring topology

Two Alarm Relay contacts monitor basic operations. One is for hardware, and will

Standard AC power input is IEC plug, auto-ranging for worldwide use. For special

„ Heavy-duty design, for Industrial Ethernet and un-controlled temp. operation

Fiber ports take more power than copper ports, but the Magnum 6K8-Series design

„ MNS-6K licensed Network Management Software included, S-Ring optional

control, RMON, CLI, Port Security; Port Mirroring; Port Settings Control; Telnet,

„ Standard AC power input, -48VDC or 24VDC or 125VDC input is optional

configuring, and password security. Secured Web Management, RADIUS X and

and application-specific priorities of data, the QoS software may be configured.

connectors. RJ-45 10/100 ports can also be configured in the mix of port types.

„ Vertical mounting for efficient convection cooling, no fans, extended temp.

Release 3.1.2 (fall ’05) includes SNMP Switch Management with secure access

speed; full-and half-duplex; classic Small Form Factor (SFF) and GBIC fiber

DC input can also be selected and configured on the DC power input models.

backbone connections, where managed network services are desired.

„ Switching services includes 802.1p QoS packet prioritization

„ Large selection of built-in fiber options at 10/100/1000Mb

„ Managed switching for high performance Ethernet LANs

60`C per UL methods, and 95°C per type test methods.

2.3 Features and Benefits

and GCI FTP Server.

Page 23 of the GarrettCom 6K8 user manual — 2.4 Applications
Page 23 · click to enlarge
Page 23

media capability is ideal for integrating future-proof fiber cabling into the LAN structure.

Equipped with lots of useful features such as a hardened Industrial enclosure, a

all critical applications. The addition of the S-Ring and Link-Loss-Learn software feature

Gigabit(1000Mb) ports, with industry-standard MNS-6K software. Magnum 6K8-Series

monitoring and signaling in Industrial floor applications. The performance characteristic

of the 6K8-Series Switches enable them to inter-connect a series of subnets (one subnet

per 6K8-Series Switch port) in a LAN traffic center. The subnet connections may be via

The mixed-media modular capability is ideal for Industrial applications where

features diversifies this managed switch to operate and perform securely and reliably in

Ethernet based mixed-media LANs and equipped with PLC computers to take readings

Magnum 6K8-Series Fiber Switches offer high performance, modularity and

higher availability to provide an effective solution for Industrial Ethernet needs. They

Switches are easily used in a variety of applications including client/server computing,

secure VLAN- performance upgrades to departmental networks, and stream traffic for

fiber or twisted pair cabling, 1000Mbps, 100Mbps or 10 Mbps speed, and full-or half-

wide spread of AC/DC power supply options, extended temperature rating and secured

kinds of networks very securely and reliably through out the Factory-floors. The DIN-

Rail Mounting options on the Magnum 6K8-, allow the Industrial Factory floor user to

VOIP and audio/video applications for a diversified combination of mixed media for

signaling and power utilities applications. The bundle of MNS-6K software operated

Series’s modularity along with MNS-6K management software features handle these

existing Ethernet LAN network cabling must be accommodated. The fiber-built-in

In an Industrial environment where the factory floors are networked with

and data from M/C Client/ Server databases and transport this important data to the

central office data warehouses the Managed 6K8-Series shines. The Managed 6K8-

provide the flexibility of 100Mbps fiber and copper ports as well as single or dual

management features qualifies the Magnum 6K8-Series Managed switch for any

allows this Managed switch to provide a very reliable highly available redundant

Industrial factory-floors, traffic control, transportations systems, monitoring and

Example 1Magnum 6K8-Series Switch for a Industrial application

network capability in any ring topology network.

2.4 Applications

duplex.

Page 24 of the GarrettCom 6K8 user manual — AC
Page 24 · click to enlarge
Page 24

10 or 100Mb fiber media, provide widespread options to the users to mix and match their

Switch. A main NT-server in a secure area protected from earthquake or fire hazards can

above normal room temp. is present in the room the network operates. Full-duplex future

the network and prioritize the sensitive and useful data. The Relay contact for the Alarms

The option for setting the ports at 10 or 100Mb on copper, and supporting the

Switch makes it an attractive choice for use in applications with LAN connections to an

feature operated through software and hardware provides extra reliability to monitor the

PL

Magnum 6K8 in a Industrial floor application to monitor and signaling PLC units

legacy and advance network needs. The modularity of the 6K8-Series Industrial Field

proof fiber media can easily connect long distance subnets and provide a stable secure

6K8-Series Switch helps create a database of all the network subnets to easily manage

organization’s multiple site offices and factory- floors. The different locations can be

easily connected together with the Fiber ports supported by the Magnum 6K8-Series

network floors and many others temp sensitive critical Industrial applications where

network to all applications. The SNMP, QOS management capability of the Magnum

Extended temp.ratings, 24V/125VDC power supply options, and IP53

approval qualifies this managed 6K8-Series switch for use in temp. un-controlled

PL PL PL

mount the 6K8 securely anywhere on their Network setup.

PL

be connected to the full duplex Gigabit Fiber port.

F/ AC

10/1 L

2 4 F/ AC

1 3 10/1 L

10/1 L

F/ AC

2 TX T LK R L

F/ AC

F/

switch operation or any power failure.

AC

10/1 L

F/ AC

2 TX T LK R L

PL

F/ AC

F/

AC

GARRE

PL

PL

Show 9 more labels / short text on this page
Interne · Route · Magnum 6K25 · Magnum 1 3 · Magnum PW · Magnum · Fiber · Managed · Swit
Page 25 of the GarrettCom 6K8 user manual — AF/ A
Page 25 · click to enlarge
Page 25

a ring switch needs to be reconfigured in milliseconds . The ring topology of the network

equipped with 802.1Q VLAN, RMON, RSTP and other standard managed LAN features

The 6K8-Series Industrial Field with S-ring and Link-Loss-Learn feature easily

network. This is needed where any faulty cable, cable disconnection or power failure in

sharing a higher bandwidth of multicast packets used for secure camera monitoring and

The NEMA TS-2 and TEES along with IP53 approval with the mix of copper

seamless solution to the requirements. The user-configurable Magnum 6K8 provides an

extra boost to the network requirements by providing copper/fiber media along with the

fulfilled the redundancy requirement in a secure and fast reconfiguration time for cable

consists of high speed LAN segments supported by 100Mbps full-duplex future-proof

data-mining for the vital database located in a controlled center secured building. The

fiber media to provide secure long distance LAN connections. The entire network is

entire spread network will be manageable to provide easy, detectable, uninterrupted

and fiber ports on the 6K8-Series Industrial Field Switch provides an economical and

Example 2. In another outdoor Ethernet Traffic monitoring application, a managed

network is needed to provide a Redundant ring topology for a maximum redundant

higher bandwidth support of 10/100Mbps. The user can utilize the SNMP feature

Fig. 2.4b-Magnum 6K8 equipped with S-Ring in redundant ring in a

CCTV

CCTV

F/ A

10/ L

2 4 F/ A

1 3 10/ L

support through a viewable SNMP monitor.

10/ L

F/ A

CCTV

to provide a secure and stable network.

2 TX T LK R L

breakup by setting up a ring topology.

AF/ A

F/

10/ L

F/ A

2 TX T LK R L

AF/ AF/

outdoor Traffic application

GARR

CCTV

CCTV

Show 11 more labels / short text on this page
Control Center SNMP · Interne · Route · Magnum 6K25 · Magnum 1 3 · Magnum · Magnum P · Managed · Fiber · Swi · Monitor
Page 26 of the GarrettCom 6K8 user manual — Magnum 6K8 Industrial Field switch in a Power Substations applications
Page 26 · click to enlarge
Page 26

communications backbone for local and remote control of real-time operational and fault

environments. The combination of 6K25 as the back bone and 6K8 at the edge provides a

Fiber and copper options make this switch ready to provide this solution and also control

The Hardened enclosed 6K8-125VDC Industrial field switch with IEEE 1613

Example 3In another example, a large Power Substation (Electric and Gas) needs a

stations also adds another example of success for this product to deploy in sub-station

seamless secure solution which can easily monitor real-time operations. Enriched with

Magnum 6K8 Industrial Field switch in a Power Substations applications

and IEC61850 approved for power stations is equipped with its modularity, secured

GarrettCom 6K8 — Magnum 6K8 Industrial Field switch in a Power Substations applications diagram (page 26)
Fig. 9 · Magnum 6K8 Industrial Field switch in a Power Substa…

analysis data. The Ethernet backbone should pass the information of SCADA local

monitoring and control via a HMI. The heart of the system evolves around several

controlled Alarm Relay which easily qualifies it to provide all the requirements of

The successful track record of previous members of the 6K-family in sub-

management features, un-controlled temp ratings along with a hardware/software

Comm.

Secure Ethernet LAN network to collect, monitor and provide a simplified

Comm.

processor Comm.

any emission noises via a fiber approach.

Comm.

communications processors.

substations.

Comm.

Show 4 more labels / short text on this page
processor · processor · processor · processor
Page 27 of the GarrettCom 6K8 user manual — 3.0 Installation
Page 27 · click to enlarge
Page 27

A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the

H) When connected to a 48 V centralized dc source, this product is to be installed only in

This section describes installation of the Magnum 6K8-Series Switches, as well

environment compatible with the maximum ambient temperature (Tma) specified by the

equipment to the supply circuit and the effect that overloading of the circuits might have

and shall be provided with a Listed 5 A DC fuse or circuit breaker in the supply circuit.

Before installing the equipment, please note the following UL/CSA60950 product

1)The external power supply for 24VDC units shall be a Listed, Direct Plug In power unit, marked Class 2, or a Listed ITE Power Supply, which has a suitably rated output

C) Mechanical Loading - Mounting of the equipment in the rack should be such that a

on over current protection and supply wiring. Appropriate consideration of equipment

Restricted Access Areas (Dedicated Equipment Rooms, Electrical Closets, or the like)

For DC power options, see Appendix B. For Dual Source, see Appendix C.

B) Reduced Air Flow - Installation of the equipment in a rack should be such that the

amount of airflow required for safe operation of the equipment is not compromised.

ambient. Therefore, consideration should be given to installing the equipment in an

operating ambient temperature of the rack environment may be greater than room

E) Reliable earthing of rack-mounted equipment should be maintained. Particular

D) Circuit Overloading - Consideration should be given to the connection of the

G) A readily accessible disconnect device shall be incorporated in the building

For vertical panel mounting and wall mounting, see Section 3.4.

hazardous condition is not achieved due to uneven mechanical loading.

F) Replacement of fuses should be only by qualified service personnel.

nameplate ratings should be used when addressing this concern.

For vertical DIN-Rail mounting, see Section 3.3.

voltage (i.e. 24VDC), and suitably rated output current.

3.1 Locating Magnum 6K8-Series Switches

as connection of the various Ethernet media types.

branch circuit (e.g. use of power strips).

safety listing requirements.

3.0 Installation

installation wiring.

manufacturer.

Mounting Instructions -

Page 28 of the GarrettCom 6K8 user manual — Copper:
Page 28 · click to enlarge
Page 28

individually selected and configured per-port. See Section 2.4 for a description

802.3, 802.3D, 802.3u, 802.3AB and 802.3z standards and connector types are as follows:

2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue

For AC power input, locate an AC receptacle that is within six feet (2 meters)

support all standard Ethernet media types within a single Switch unit. This is

1. Before connecting the fiber optic cable, remove the protective dust caps from the

dampened in alcohol. Make certain the connectors are clean before connecting.

of the intended Magnum 6K8-Series site. The rugged metal case of the Magnum 6K8-

Maintain an open view of the front to visually monitor the status LEDs. Keep an open

The following procedure applies to installations using a PM with ST-type fiber

Series will normally protect it from accidental damage in a lab or workplace setting.

electronics use the case as a heat sink, so the unit may normally be quite warm to the

The various media types supported along with the corresponding IEEE

connectors. This procedure applies to ports using a 6K8-Series module, MST-

The Magnum 6K8-Series Switches are specifically designed to

area around the unit so that cooling can occur from convection while the unit is in

operation. The 6K8-Series has no fans, so it is silent when in operation. Internal

accomplished by using a family of different port Modules which can be

small form factor mm1 Fiber 2.0km (6,562 ft) 6K8-MTRJ, -MLC small form factor sgl.m1 Fiber 15 km 6KP8V- SLC

bands at regular intervals; you must use the color-coded strand on the

IEEE Standard Media Type Max. Distance Port Module

100BASE-FX mm1 Fiber 2.0km (6,562 ft) 6K6-MSC, -MST

1000BASE-TX GBPM-RJ45

sgl.m2 Fiber 5,10,25,70Km GBIC-LXSC

1000BASE-FX mm1 Fiber 220m ( ft) GBIC-SXSC

sgl.m2 Fiber 18.0km (95K ft) SSC, SSCL

10BASE-T,100BASE-TX twisted pair 100m (328 ft) 6K8-RJ45

3.2.1 Connecting Fiber Optic ST-type, “twist-lock”

associated ports at each end of the fiber optic segment.

1 mm = multi-mode 2 sgl.m = single-mode

3.2 Connecting Ethernet Media

touch.

of the PMs.

type port.

Copper:

Fiber:

Page 29 of the GarrettCom 6K8 user manual — Shielded)
Page 29 · click to enlarge
Page 29

The following procedure applies to installations using a PM with SC-type fiber

(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx

fiber allows full bandwidth at longer distances, and may be used to connect 10 Mb nodes

may be used. In either case, the maximum distance for unshielded twisted pair cabling is

mixed-speed network, since dual-speed ports are auto-sensing for either 10 and

connection has been established at both ends (and when power is ON in

connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable

The RJ-45 ports of the Magnum 6K8-Series can be connected to the following

making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3

The following procedure describes how to connect a 10BASE-T or 100BASE-

3. Connect the Transmit (TX) port (light colored post) on the Magnum PM to the

Receive (RX) port of the remote device. Begin with the color-coded strand of

(TX) port of the remote device. Use the non-color coded fiber strand for this.

5. The LINK LED on the front of the PM will illuminate when a proper

improper cable polarity. Swap the fiber cables at the PM connector to

are the diameters of the core and the core plus the cladding respectively). Single-mode

Twisted Pair (CAT 3, 4, 5) 10BASE-T RJ-45

TX twisted pair segment to the RJ-45 port. The procedure is the same for both

4. Connect the Receive (RX) port (dark colored post on the PM) to the Transmit

the unit). If LINK is not lit after cable connection, the normal cause is

connectors into the SC female jacks of the 6KPM module until it clicks and secures.

When using single-mode fiber cable, be sure to use single-mode fiber port

The same procedures as for multi-mode fiber, applies to single-mode fiber

two media types100BASE-TX and 10BASE-T. CAT 5 cables should be used when

3.2.4 Connecting Twisted Pair (RJ-45, CAT3, CAT5, Unshielded or

Twisted Pair (CAT 5) 100BASE-TX RJ-45

and 100Mb) be used whenever possible in order to provide flexibility in a

While connecting fiber media to SC connectors, simply snap the two square male

Media IEEE Standard Connector

3.2.2 Connecting Fiber Optic SC-type, "Snap-In"

connectors. Follow the steps listed in Section 3.2.2 above.

connectors, i.e., using 6K-MSC, 6K-SSC single-mode.

3.2.3 Connecting Single-Mode Fiber Optic

the cable for this first TX-to-RX connection.

up to 10 Km apart, or 18Km with the 6K-SSC.

remedy this situation.

100 meters (328 ft).

100Mb/s.

Shielded)

Page 30 of the GarrettCom 6K8 user manual — Shielded)
Page 30 · click to enlarge
Page 30
1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is
4. The auto-cross(Auto-MDIX) feature will eliminate the use of crossover cable, while connecting the RJ-45 ports to any other RJ-45 device.

(STP) balanced cable is recommended to use when making 1000BASE-TX connections.

In either case, the max distance for unshielded twisted pair cabling is 100 meters (328 ft).

Mb and 1000Mb) be used whenever possible in order to provide flexibility in a

2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established.

The following procedure describes how to connect a 1000BASE-T twisted pair segment

1. 1000Base-T connections require that all four pairs or wires be connected. Insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port.
2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established
GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 30)
Fig. 10 · 3.1 Locating Magnum 6K8-Series Switches

The RJ-45 Gigabit ports of the Magnum 6K8-Series can be connected to the

media types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair

to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted

(STP) balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair

3.2.5 Connecting Twisted Pair (CAT5E or better, Unshielded or

Media IEEE Standard Connector

shielded, either unshielded or shielded cables and wiring may be used.

Twisted Pair (CAT 5E) 1000BASE-T RJ-45

The Magnum 6K8 is designed for use in a “factory

The Gigabit ports accept industry-standard GBICs for

3.2.6 Connecting Gigabit Media Using GBICs

floor” industrial environment. It is available with optional

DIN-Rail brackets to mount it securely in a metal factory

user selection of the gigabit media type desired. A

selection of fiber and copper GBICs are available.

unshielded and shielded twisted pair cables.

cables and wiring may be used.

3.3 DIN-Rail Mounting

mixed-speed network.

Shielded)

pair cables.

Page 31 of the GarrettCom 6K8 user manual — 3.1 Locating Magnum 6K8-Series Switches
Page 31 · click to enlarge
Page 31

upper rear corners of the 6K8 unit. Two threaded

Rail mounting purposes. See side view at the left,

Rail brackets, and are no.10-32 X 3/8 PHIL. PAN

DIN-Rail latches and brackets are heavy duty, and will hold the 6K8 securely in position,

Magnum 6K8 requires two DIN-Rail mounting clips or latches for secure mounting, and

The Din Rail Latching clips are mounted on the

with the top of the unit pointed to the right. The

latches are designed as if that they can be manually accessed from the top when the 6K8

To install the 6K8 with the DIN-Rail brackets and latches attached to it, hold the

DIN-Rail. Position the latches over the top of the DIN-Rail. Then, snap the latches into

pulling the bottom out. Once the bottom of the 6K8 is rotated out, the DIN-Rail latch is

these may be ordered as Model # DIN-RAIL-6K8. See a 6K8 viewed from the rear, at

holes are provided on the sides of 6K8 for DIN-

required two screws are included with the DIN-

6K8 in the vertical position with the bottom out, and with the top moved in toward the

To release the 6K8 from the DIN-Rail mounting, press the top of the two DIN-

from the rear of the panel by the mounting brackets. The 6K8 design uses the case for

cooling (patent pending), and needs to be mounted vertically with air flow space in the

floor enclosure, maintained vertically for proper convection cooling of the unit. The

w/star washer. The two heavy duty Din-Rail

holding position by moving the bottom of the 6K8 inwards to a vertical position. The

Rail latches down simultaneously to release the 6K8 so that it can be dismounted by

not engaged and the 6K8 can be moved up and out, free of the DIN-Rail mounting..

The picture below is a front / right-side view of a DIN-Rail mounted 6K8. It

shows vertical mounting of Magnum 6K8 on a DIN-Rail track for proper convection

cooling of the unit. Note that there is air space in the rear, as the 6K8 unit is held out

right, with model DIN-RAIL-6K8 in place on the unit.

even with cabling attached to the unit.

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 31)
Fig. 11 · 3.1 Locating Magnum 6K8-Series Switches

is installed on a DIN Rail.

front, rear, and sides.

Page 32 of the GarrettCom 6K8 user manual — Magnum 6K8
Page 32 · click to enlarge
Page 32

the plate. Place two of the screws,

have the 5lbs/in torque minimum.

3. Select the height position via indented side marking .
4. Place the DIN Rail Clip assembly under indented side of

came along the kit (#10-32 x ¼

undercut) onto the indented side

and screw tight the assembly as

2 2 #10-32 x ¼ Phillip Flat head screws with

Phillip Flat head screws with

b. “1” indentation signify center of the mounted Din-Rail clip location.

c. Each indented locations (1-11-111…) are ½ inches apart from the center.

shown in Fig 2a.

1. Remove the back plate from Magnum 6K8 UNIT a. There are eight screws along the edge of the unit to remove.

Fig 1.

3 8 #4-40 x 3/8 Phillip Flat head screw

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 32)
Fig. 12 · 3.1 Locating Magnum 6K8-Series Switches
2. On the back-plate a. Locate the indented side with 1, 11……

Magnum 6K8 Din-Rail kit comes along

ordered as separate items, e.g Model # DIN-

Din-Rail kit Installation procedures:

The DIN-Rail mounting brackets

1 1 DIN Rail Clip assy

vertically with DIN-Rail brackets and

and latches are optional and need to be

b.. Do not re-use the old screws.

Fig 3.3 - Magnum 6K8 mounted

3.3.1 Installing DIN-RAIL

variable brackets on

with the following-BOM:

Magnum 6K8

RAIL-6K8

Item Quantity Description · latches · undercut

Page 33 of the GarrettCom 6K8 user manual — side Fig. 2b: Din-Rail assembly w/plate
Page 33 · click to enlarge
Page 33
GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 33)
Fig. 13 · 3.1 Locating Magnum 6K8-Series Switches

The final Din-Rail assembly mounted on the Magnum 6K8 is shown below

a. The Din-Rail clip must be on top, while positioning the clip as shown in Fig. 2b with

5. Remount the Din-Rail assembled plate onto the Magnum 6K8, using the 4-40

side Fig. 2b: Din-Rail assembly w/plate

applied to mount the Din-Rail assembly

Fig. 2a: 10-32 Screws on indented

GarrettCom 6K8 — side Fig. 2b: Din-Rail assembly w/plate diagram (page 33)
Fig. 14 · side Fig. 2b: Din-Rail assembly w/plate

screws.

on Fig. 3

underneath.

arrow mark.

Page 34 of the GarrettCom 6K8 user manual — Fig . 3
Page 34 · click to enlarge
Page 34

mount the unit securely. It is recommended to mount the 6K8 vertically, as shown below,

creating a rear space of about ¼ inch or 1cm. This allows air circulation and cooling of

the rear part of the case. Since the 6K8 uses special internal thermal techniques (patent

Each Mangum 6K8 is supplied with metal mounting brackets and screws to

pending) to move the heat generated by the electronic components inside into the case,

for proper cooling and long-life reliability. It is also advisable to mount the unit with

space for air movement around the top and the sides, typically a minimum of 1 inch..

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 34)
Fig. 15 · 3.1 Locating Magnum 6K8-Series Switches

3.3.2 Mounting Dimensions for 6K8 with metal brackets

the case may be quite warm to the touch during normal operation.

Fig . 3

Page 35 of the GarrettCom 6K8 user manual — 3.1 Locating Magnum 6K8-Series Switches
Page 35 · click to enlarge
Page 35

supply and have a recessed male IEC connector for the AC power cord at the left-rear. A

AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz.

Ethernet cabling, there is no need to power down the unit. Individual cable segments can

be connected or disconnected without concern for AC power-related problems or damage

The unit can be mounted using the brackets turned outside (normal) or inside (if space is

above (dotted line shown for the brackets inside). The spacing for the mounting screws

The 16-port units will consume over 20 watts of power typically. When connecting the

Power supply options are available to suit the 6K8-Series Switches to special

tight). Attach the mounting bracket either outside or inside as shown in the illustration

manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard power

The auto-ranging power supply supports installation environments where the

The Magnum 6K8-Series Switches incorporate an internal universal power

cord is supplied with each unit shipped within the United States and Canada.

into the supporting wall or panel is a rectangle 11.89” x 7.85” center-to-center.

3.4 Powering the Magnum 6K8-Series Industrial Field Switch

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 35)
Fig. 16 · 3.1 Locating Magnum 6K8-Series Switches

to the unit.

Page 36 of the GarrettCom 6K8 user manual — 3.6 6K8-Series Port Module (6KPMV) Installation
Page 36 · click to enlarge
Page 36
GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 36)
Fig. 17 · 3.1 Locating Magnum 6K8-Series Switches
1. There is four terminal block (1,2,3,4) provided next to AC/DC power supply 2. The top two pins (1,2) are software operated 3. The bottom two pins (3,4) are hardware operated 4. By default it is NC (normally closed) 5. The software operation needs to be enabled and set to get the Alarm traps. For detail information about the Software Alarm and software control of SNMP alarm traps, please

The Alarm Contact is on the front left area (next to the DC power source) of

high-availability communications and/or heavy industrial-grade applications, including:

3.5 Alarm Contacts for monitoring internal power, and Software Traps The Alarm Contacts feature, standard on Magnum 6K8-Series’s, provides

terminal block for Alarm Contacts is part of the Power Input panel in the Magnum 6K8-

The first NC Alarm Contact (top position) is a “Software Alarm”, operated

order the right module for this unit. In the Port Module materials below, all modules are

’s case. The AC or DC power input connection is in the same panel. A manual On-Off

those used in 6K16V units. The modules have the letter “V” in the model numbers, to

two Form C Normally Closed (NC) contacts to which the user can attach two sets of

status monitoring wires at the green terminal block. When this option is present, the

Switch for power to the unit is not available on 6K8- units with the Alarm Contacts

by user settings in the MNS-6K software. The user can disable the Software Alarm

See the Appendices B & C of this manual for more details. Use an RFQ for other

supply inside of the Magnum 6K8- Switch. Useful info. about Alarm contacts:

the Magnum 6K8-Series unit and is green in color as shown in the picture.

reference the Magnum MNS-6K Software User Manual. (Chapter 19th).

Software Security violation or an S-Ring Fault, causes the contact

3.6 6K8-Series Port Module (6KPMV) Installation

* -48VDC, 24VDC and 125VDC with dual-source DC input,

feature with a software configuration command if desired. When

to open and thus trigger an alarm in the user’s monitoring system

The second (bottom position) NC Alarm Contact is

option, as these two features occupy the same space in the case.

(NC) contact is held close during normal software operation. A

user-defined software malfunction, such as an SNMP Trap or a

held close when there is power on the main board inside of the

the Software Alarm is enabled, the Form C Normally Closed

6K8-. This provides a “Hardware Alarm” because the NC contacts will open when internal power is lost, either from an

external power down condition or by the failure of the power

* -48VDC, 24VDC and 125VDC with single DC input,

variations.

Relay Contacts

Page 37 of the GarrettCom 6K8 user manual — STOP!!!
Page 37 · click to enlarge
Page 37
1. Make sure the 6KPMV Card package has all necessary accessories and use the

(smaller), three 5/8 stand offs for Granddaughter board, 6 standoff for daughter

Magnum 6K8-Series Switches are normally received from the factory with all

required 6KPMV modules installed. There may be situations where 6KPMV cards need

faceplate for an available front-mounted slot must be removed. The following procedure

describes this operation. The pictorial view of the hardware assembly can be seen here-

Do not change the Blue color DIP Switch setting ever! Leave it at factory default.

Board, nine #4-40x3/8 Pan-Head screws along with Front panel face plate

Granddaughter board. The copper 6KPMV card should not work properly if mixed

to be added or replaced. In cases where additional 6KPMV cards are needed, the

3.6.1 Preparation for Installing and Removing 6KPMVs from 6K8’s

equipment) are sensitive to static discharge. Use proper ESD measures when

proper tool to install it properly. Each 6KPMV Card package, for field

installation contains (Daughterboard (Bigger) and Granddaughter board

with other Fiber combo 6KPMV card packages. Always install the PM module

referred to as “6KPMV” for convenience in describing port module installation.

Failure to do so may result in damage to the unit

from the chassis before attempting to remove

http://www.garrettcom.com/Pictorial/6k8_pictorial.pdf

Be sure the power cord is unplugged

and/or replace any PM cards.

and will void the warranty.

STOP!!!

separately one by one to avoid the mixing.

2. Remove Chassis Cover

handling port modules.

package.

Page 38 of the GarrettCom 6K8 user manual — 3.1 Locating Magnum 6K8-Series Switches
Page 38 · click to enlarge
Page 38

Daughter board Power LED, Pin J5 Power Supply, Pin DSSV

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 38)
Fig. 18 · 3.1 Locating Magnum 6K8-Series Switches

daughter module on the

chassis assembled together with the help of 12 Philips-head screws. There are 4 screws

module installed and daughter module would be facing your eyes on the top installed on

The Magnum 6K8-Series chassis consists of top cover and bottom

exposed. Looking down into the Magnum 6K8-Series unit, notice that there are PM

Figure 3.6.1b:

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 38)
Fig. 19 · 3.1 Locating Magnum 6K8-Series Switches

the main board with J5 and DSSV pins connected on the right. (See Figure 3.6.1b)

When the chassis top cover has been removed, the interior of the unit is

top.

Figure 3.6.1cTop View – 6KPM retaining screws hold Face Plate
GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 38)
Fig. 20 · 3.1 Locating Magnum 6K8-Series Switches

arrow mark in Fig 3.6.1c holding the face plate of

There are four retaining screws as shown with

3. Remove front panel face plate

located on the top-side panel of the unit

screws. Once these screws are removed,

chassis base of the unit. Remove these

the top-cover is easily slide out to the

front, off the chassis base, as shown in

Figure 3.6.1aRemoving the Top

panel from the Chassis base of the

(2 each on both side), 8 for bottom

retaining screws and screen plate

the picture above in Fig. 3.6.1a.

with arrow mark.

the chassis.

below.

Show 4 more labels / short text on this page
Magnum 6K8-Series, · Top view without · chassis cover w/ · unit
Page 39 of the GarrettCom 6K8 user manual — 3.6.2 Installing 6KPM Cards in the Magnum 6K8-Series
Page 39 · click to enlarge
Page 39

front cover can be removed easily as shown in Fig

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 39)
Fig. 21 · 3.1 Locating Magnum 6K8-Series Switches

(female) provided at the front of

the 6K8-Series Main Board. To

2. Place Granddaughter

board (as shown in fig. 3.6.2b)

on the chassis built in stand off

place the Granddaughter board

Figure 3.6.1dRemoving

Once opened all the four retaining screws the

Only one front-mounted 6KPMV Module may be installed in one Magnum

on the chassis, as shown in

6K8-Series Field Switch unit. Follow these steps to install a 6KPMV.

PM screen Plate

1. Remove top chassis cover. See procedure in Section 3.6.1 above.

Fig 3.6.2a A Magnum 6K8 unit with main board(motherboard) only

3.6.2 Installing 6KPM Cards in the Magnum 6K8-Series

3.6.1d. on the left.

GarrettCom 6K8 — 3.6.2 Installing 6KPM Cards in the Magnum 6K8-Series diagram (page 39)
Fig. 22 · 3.6.2 Installing 6KPM Cards in the Magnum 6K8-Series
Figure 3.6.1dRemoving Face Plate

Carefully remove the PM screen plate

3.6.1d on the right. Just be careful on the LEDs placed both side and hold

GarrettCom 6K8 — 3.6.2 Installing 6KPM Cards in the Magnum 6K8-Series diagram (page 39)
Fig. 23 · 3.6.2 Installing 6KPM Cards in the Magnum 6K8-Series

using finger or small screw driver to

the face plate tightly. There are no

screws used on holding the screen

come out easily as shown in Fig

face plate.

Page 40 of the GarrettCom 6K8 user manual — 3.1 Locating Magnum 6K8-Series Switches
Page 40 · click to enlarge
Page 40

of the Granddaughter board. The three 5/16 stand off has been used to place the daughter

board on the top of the granddaughter board and a latch connector to hold it securely.

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 40)
Fig. 24 · 3.1 Locating Magnum 6K8-Series Switches

Fig 3.6.2c Granddaughter Board placed in slot & secured with three 5/16 standoff’s

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 40)
Fig. 25 · 3.1 Locating Magnum 6K8-Series Switches

Figure below 3.6.2c, screw down tightly with the three 5/16 stand-off (male) on the top

Fig 3.6.2e Daughter Board shown upside down with two

end and insert the 6KPMV module inside the front face plate slot carefully. Then align

board with the other female connector placed on the Granddaughter and main board. As

Fig. 3.6.2f Magnum 6KPM

properly in front plate slot

4. Hold the daughter board with both hands at the
3. The figure here illustrates the basic layout of an individual PM card. Each

the two cream color latching connectors (male) placed at the bottom of the daughter

with the bottom latch

Fig. 3.6.2d Daughter Board, top view of

6KPM card fits into the space provided on the main board.

4 copper 10/100 ports

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 40)
Fig. 26 · 3.1 Locating Magnum 6K8-Series Switches

Fig 3.6.2b Granddaughter

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 40)
Fig. 27 · 3.1 Locating Magnum 6K8-Series Switches

shown below in Fig. 3.6.2f.

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 40)
Fig. 28 · 3.1 Locating Magnum 6K8-Series Switches
Show 5 more labels / short text on this page
Female latch connector · daughter board aligned · connector after inserted · male latch connectors · Board shown separately
Page 41 of the GarrettCom 6K8 user manual — DSSV
Page 41 · click to enlarge
Page 41
GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 41)
Fig. 29 · 3.1 Locating Magnum 6K8-Series Switches

aligned with stand offs then press slowly and firmly with two fingers (as shown

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 41)
Fig. 30 · 3.1 Locating Magnum 6K8-Series Switches
5. Once the latching connectors are aligned properly and the mounting holes are

below in Fig. 3.6.2f)

on the face of the module securely and carefully. Now screw down properly the

latched up securely.

Figure 3.6.2f:

on the top of the

J5

6. Now screw down the daughter board with 6 #440 screws,

so that it holds the daughter board securely. The figure on

Power supply cable(pin DSSV) connected to the board

GarrettCom 6K8 — J5 diagram (page 41)
Fig. 31

6KPMV cards inside and the Power Led(pin J5) and

the left shows the top view of successfully installed

6KPMV Cards into a Magnum 6K8-Series

7. Once the installation of granddaughter and

screen plates of 6KPMV need to be placed

pins as shown in Fig 3.6.2g with arrows.

daughter modules is done, the front panel

Fig. 3.6.2g Top View6KPM Module

installed and insight for connecting two

wires to the right pins

DSSV

Show 4 more labels / short text on this page
latching up · latching connectors · until the connectors · Securely
Page 42 of the GarrettCom 6K8 user manual — track
Page 42 · click to enlarge
Page 42
GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 42)
Fig. 32 · 3.1 Locating Magnum 6K8-Series Switches

To properly remove a 6KPM card from the 6K8-Series Industrial Field Switch,

8. Once 6KPMV card have been installed (including faceplate and screen plate),

the chassis cover should be replaced. Make sure the chassis top cover is aligned

properly to the base before securely sliding the chassis base track inside the top

cover properly as shown in

sliding in the top cover

face plate with 4 screws to complete the installation process for port module.

The front panel screen plate does not need any screws to hold on port module,

onto the chassis base

2. Remove retaining screws placed on top of the 6KPMV and Face Plate

Fig. 3.6.2h

1. Remove chassis cover See procedures in Section 3.6.1 above.

but need to place tightly and carefully while placing on LEDs.

Fig 3.6.2h

track

3.6.3 Removing 6KPM Cards

follow the 3 steps below.

screws #440x3/8. These screws

to take off the daughter module

3.6.3a). Remove the 9 screws

and thereafter three standoffs

card in position (see Figure

secured with nine retaining

are used to secure a 6KPM

Each 6KPMV module is

Page 43 of the GarrettCom 6K8 user manual — 3.7 Connecting a Management Console Terminal to Magnum 6K8
Page 43 · click to enlarge
Page 43

Carefully and gently pull out the daughter board from the latching connectors,

using both hands, gripping the board near the latch-up connectors as shown in Fig. 3.6.3b

underneath holding the Granddaughter board with the chassis. Figure 3.6.3a: 8

Use a DB-9 “null modem” cable (use on any serial port)or “one DB-9 and one USB” (

USB port on the laptop) null modem cable to connect the Magnum6K8-Series Console

Magnum 6K8-Series Switch configuration for Network Management, please refer to

3.7 Connecting a Management Console Terminal to Magnum 6K8

communicate with 6K-Series Switches, please follow the “Quick Step Guide” come

Port (the RS-232 port on the 6K8-Series Switch) to the your PC, so that your PC

becomes the 6K8-Series’s Console Terminal. For Hyper terminal configuration to

http://www.garrettcom.com/techsupport/software/upgrade_mns6k.pdf

with the 6K8-Series unit. They are not “bundled” with the unit.

Fig 3.7 Enlarged view of Magnum 6K8-Series Console Port area

GarrettCom 6K8 — 3.7 Connecting a Management Console Terminal to Magnum 6K8 diagram (page 43)
Fig. 33 · 3.7 Connecting a Management Console Terminal to Magn…

retaining screws shown by arrows

3. Remove 6KPM Card

Follow the steps as described

All the same procedures will

for installing a 6KPMV card

Removing a 6KPM Card

6KPMV module from 6K8-

Series managed switches.

apply for replacing any

discussed in step 3.7.1.

along with the Switch.

Figure 3.6.3b:

Consoleor Serial.

(DB-9) Port

Page 44 of the GarrettCom 6K8 user manual — 3.1 Locating Magnum 6K8-Series Switches
Page 44 · click to enlarge
Page 44

The above information enables a management station ( a PC or Console terminal) to

3.7.1 RS-232 (DB-9) Console Com port (Serial port) pin assignments.

Magnum 6K8-Series Software Manual available on GarrettCom‘s FTP site. Please

connect directly to the Switch Console using a straight-through serial cable.

1 CD Carrier detect (not used)

3 TXD Transmit Data (output)

2 RXD Receive Data (input)

5 GND Signal Ground

refer Section 2.2.9 of this manual for download information.

4 open not used

6-9 open not used

Pin 1 Pin 5

DB-9 (Console port connector)

Pin Signal Description

Page 45 of the GarrettCom 6K8 user manual — 4.0 OPERATION
Page 45 · click to enlarge
Page 45

Each time a packet arrives on one of the switched ports, the decision is taken to

either filter or to forward the packet. Packets whose source and destination addresses are

on the same port segment will be filtered, constraining them to that one port and relieving

is on another port segment will be forwarded to the appropriate port, and will not be sent

This chapter describes the functions and operation of the Magnum 6K8-Series

A Magnum 6K8-Series provides switched connectivity at Ethernet wire-speed

100Mbps selection for the switched ports must be configured through MNS software per

the rest of the network from having to process them. A packet whose destination address

The Magnum 6K8-Series Switches operate in the store-and-forward switching

mode, which eliminates bad packets and enables peak performance to be achieved when

An address-aging algorithm causes least-used addresses to fall out in favor of

among all of its ports. The Magnum 6K8-Series supports10/100Mbs for copper media

utilization and network performance. All ports can communicate to all other ports in a

Magnum 6K8-Series, but local traffic on a port will not consume any of the bandwidth

configuring necessary to be done for basic operation at installation or for maintenance.

(resides inside the unit) on the 6K8-RJ45. Optional Half / Full duplex mode and 10 or

Magnum 6K8-Series units are plug-and-play devices. There is no software

addresses suitable for use in larger networks. They are self-learning, so as nodes are

The only hardware configuration settings are user options for an UP-LINK Switch

frequently-used addresses. To reset the address buffer, cycle power down-and-up.

and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth

All Magnum 6K8-Series units have address table capacities of 4K node

unit as per the requirement. The internal functions of both are described below.

interrupted operation of the network (such as occasional multi-cast packets) are

added, removed or moved from one segment to another, the 6K8-Series Switch

to the other ports where it is not needed. Traffic needed for maintaining the un-

automatically keeps up with node locations.

4.1 Switching Functionality

there is heavy traffic on the network.

4.0 OPERATION

forwarded to all ports.

Switch.

on any other port.

Filtering and Forwarding · Address Learning

Page 46 of the GarrettCom 6K8 user manual — 4.2 Dual LEDs Status on TOP and Front of the 6K8-Series unit
Page 46 · click to enlarge
Page 46

PWR/POWER : Power LED, ON when external power is applied to the unit.

ACT : ON with port activity for 10 Mbps and 100Mbps operation.

F/HFull / Half duplex LED, ON when the port is running full duplex,

copper ports is to connect one of them using a fiber media converter to another Switch in

desirable to operate the fiber link at 100Mb speed, and at either half- or full duplex mode

LK/LINK : Steady ON, Link status for 10 Mbps and 100Mbps operation.

The Managed 6K8-Series Fast Ethernet copper ports, can be set for either fixed 100Mb

selection is made via MNS software. The factory default setting is for auto-negotiation.

At 10Mb or 100Mb-fixed speed, the user may select half- or full-duplex mode by MNS

One frequently-used application for the Managed Magnum 6K8-Series Switch

10/100 : Speed LED, ON when the speed is 100Mbps, OFF when the speed is 10 Mbps

The RJ-45 ports independently support auto-cross (MDI or MDIX) in

converter) or fixed mode at 10Mb or 100Mb Half/Full Duplex(managed switch). No

Software for each RJ-45 port separately. For detail information See Section (10.1 at

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 46)
Fig. 34 · 3.1 Locating Magnum 6K8-Series Switches

auto-negotiation mode and will work properly with all the other connected devices

with RJ-45 port whether it supports Auto-negotiation or not (e.g 10Mb Hub, media

speed or for 10/100 F/H N-way auto-negotiation per the IEEE802.3u standard. The

page no.52) of this manual to access the “6K-MNS(Rel 3) Software user guide”

4.2 Dual LEDs Status on TOP and Front of the 6K8-Series unit

4.3 Auto-Cross(MDIX) and Auto-negotiation, for RJ-45 ports

cross-over cable is required while using the 6K8’s copper port to other devices.

the network backbone, or to some other remote 100Mb device. In this case, it is

Operation is according to the IEEE 802.3u standard.

OFF for half duplex.

Page 47 of the GarrettCom 6K8 user manual — 3.1 Locating Magnum 6K8-Series Switches
Page 47 · click to enlarge
Page 47

When Magnum 6K8-Series RJ-45 copper ports are set for auto-negotiation and

may be limited within that collision domain. The Path Delay Value (PDV) bit-times must

Fast Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.

Attachment to 10/100 auto-negotiation ports typically will not work properly. The 6K8-

modes possible depending on what the other device supports. These are: (1) 100Mb full-

The auto-negotiation logic will attempt to operate in descending order and will normally

mode” result can change at any time depending on network changes that may occur). If

Series Switch’s RJ-45 ports handle this situation by configuring the ports as per desire

through MNS software port settings and can check the port status of each port after the

arrive at the highest order mode that both devices can support at that time. (Since auto-

ports will try to detect its idle signal to determine 10 or 100 speed, and will default to

-- the devices at both ends of the cable are capable of operation at either 10

  • NOTE – Some NIC cards only auto-negotiate when the computer system

When operating in 100Mb half-duplex mode, cable distances and hop-counts

account for all devices and cable lengths within that domain. For Magnum 6K8-Series

depending on the capabilities of the remote device. Standard commercially available

Fast Ethernet media converters mostly do not support auto-negotiation properly, and

require that the switched port to which they are connected be at 100Mb fixed speed.

are connected to another auto-negotiating device, there are 4 different speed and F/H

negotiation is potentially an externally controlled process, the original “highest order

the device at the other end is not an auto-negotiating device, the 6K8-Series’s RJ-45

Auto-negotiation per-port for 802.3u-compliant switches occurs when:

that they are in is powered up. These are exceptions to the “negotiate at

duplex, (2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex.

-- the second of the two connected devices is powered up*, i.e., when

LINK – enabled” rule above, but may be occasionally encountered.

-- the LINK is re-established on a port after being lost temporarily.

Mb or 100Mb speed and/or in full- or half-duplex mode, and can

send/receive auto-negotiation pulses, and . . .

half-duplex at that speed per the IEEE standard.

LINK is established for a port, or

change.

General information -

Page 48 of the GarrettCom 6K8 user manual — Fiber Media
Page 48 · click to enlarge
Page 48

attempting to transmit to one 100Mb port, and in other protracted heavy traffic situations.

port for sufficient time to let the Switch reduce the buffer space used. When the available

(enable/disable) through setport command of MSN-6K software as per the requirement of

and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LXSC25)

and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km(LXSC40)

and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (LXSC70)

Magnum 6K8-Series Switches incorporate a flow-control mechanism for Full-

burst of activity causes the switch to save frames until its buffer memory is full. This is

blocking) on Full-Duplex ports, which provides for a “PAUSE” packet to be transmitted

algorithm on 10/100 Mb ports for flow control. That is, the switch prevents frames from

receiving. This temporary “collision” delay allows the available buffer space to improve

to the sender when the packet buffer is nearly filled and there is danger of lost packets.

The transmitting device is commanded to stop transmitting into the 6K8-Series Switch

Receiver Sensitivity and Transmitter Power are the parameters necessary to

Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long

most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the

transmitter to start sending the packets. Of course, the transmitting device must also

entering the device by forcing a collision indication on the half-duplex ports that are

4.5 Power Budget Calculations for Magnum 6K8-Series PM’s with

support the 802.3x flow control standard in order to communicate properly during

compute the power budget. To calculate the power budget of different fiber media

where the “Cable Loss” for 62.5/125 and 50/125µm (Mm) is 2.8 dB/km,

10Mb port is unable to keep up. It can also occur when multiple 100Mb ports are

Magnum 6K8-Series Switches implement the 802.3x flow control (non-

free-buffer queue increases, the Switch will send a “RESUME" packet to tell the

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

installations using Magnum products, the following equations should be used:

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

as the switch catches up with the traffic flow. The flow control option may

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

4.4 Flow-control, IEEE 802.3x Standard

network. By default the Flow control is disabled.

OPB (Optical Power Budget) = PT(min) - PR(min)

normal operation.

Fiber Media

Page 49 of the GarrettCom 6K8 user manual — ZXSC40
Page 49 · click to enlarge
Page 49
GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 49)
Fig. 35 · 3.1 Locating Magnum 6K8-Series Switches

Lucent’s) web sites and catalogs to provide guidance to network designers and installers.

mode 18+ (0.4) 1300 9/125 -15 -31 14 28 17.5 35

mode 40 (0.4) 1300 9/125 -5 -34 29 58 32.5 65

mode 2 (0.4) 1300 62.5/125 -19 -31 12 4 16 5.7

Mode 15+ (0.4) 1310 9/125 -15 -28 11 22 - -

1000Mb Multi- mode 0.55 850 62.5/125 50/125 -9.5 -17 5.5 2 12.5 4

1000Mb Single- mode 10 1300 9/125 -9.5 -20 8.5 17 10.5 21

1000Mb Single- mode 25 1550 9/125 -4.0 -21 15 37.5 17.5 43

1000Mb Single- mode 40 1550 9/125 -4.0 -21 15 60 17.5 70

1000Mb Single- mode 70 1550 9/125 -3.0 -23 18 90 20.5 102

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only if the

  • The worst-case OPB of the fiber link must be greater than the fiber cable’s

The following data has been collected from component manufacturer’s (Agilent’s and

  • The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the

full-duplex (factory default) setting for 100Mbps fiber ports must be used,

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

following factors are both applied:

passive Attenuation.

ZXSC40

ZXSC70

GBIC-

GBIC-

and

Page 50 of the GarrettCom 6K8 user manual — 5.1 Inspecting the Package and Product
Page 50 · click to enlarge
Page 50

5.0 Introduction - Magnum 6K8 Industrial Field Switch Port Modules

This section applies only to PMs shipped as separate items, i.e., if 6K8 PMs not

during shipment or delivery. Inspect the contents of this package for any signs

flexible mixed-media connectivity to RJ-45 and fiber media. Since the Magnum

Remove the 6K8-Series PM(s) from the shipping container. Be sure

An important feature of the Magnum 6K8-Series is the use of Port Modules for

6K8-Series Switches have dual-speed capability for copper ports, the 2, 4, 6 or

8-port interfaces are designed to support all standard Ethernet media types at 10

connecting Ethernet media segments with all similar or combo connector type.

compared to 6K8- but addressed as e.g 6KP8V-RJ45 . For a correct list of

installing a 6K8 PM; notify the carrier of any damage you believe occurred

contact your supplier. If you need to return the unit, use the original shipping

or 100 or 1000Mps speed. Each 6K8-Series PM provides a wide selection of

used for COMBO module are featured with Auto-negotiation and Auto-Cross

separately at a later date. In the event there are items missing or damaged,

Each 6K8-Series PM is individually described in the following sections.

This chapter describes each Port Module (PM), including appearance,

Examine the shipping container for obvious damage prior to

to keep the shipping container should you need to ship any of the PMs

container if possible. Refer to Chapter 5 for specific return procedures.

of damage and ensure that the items listed below are included.

Installation instructions, with illustrations

1 6K8-Series (6K8- series KPMVs)

6K8 Port Module types, refer to Section 1.2

factory installed in a Magnum 6K8 PM slot.

5.1 Inspecting the Package and Product

5.2 6KPMV Module Description

functionality, and status displays.

This package should contain:

(MDIX).

Page 51 of the GarrettCom 6K8 user manual — ACTIVITY
Page 51 · click to enlarge
Page 51

5.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist lock” Combo Module

port supports fiber optic cable distances up the IEEE-standard 100Mbps distance limits,

Link (LK) LED that indicates proper connectivity with the remote device when lit, and

The 6KP6-RJ10ST is a six port combo module that looks similar to

The ST-connector functions as a fiber optic transceiver to support 10BASE-FX network

supports the standard distance 100m on each port and the fiber port supports fiber optic

cable distances up the IEEE-standard 10Mbps distance limits, i.e., typically 2km at full-

Link (LK) LED that indicates proper connectivity with the remote device when lit, and

10/100Mbps and two fiber optic ports at 100MB. The Combo module is equipped with

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The

5.2.1a 6KP6-RJ10ST, 4@10/100Mbps RJ-45 and 2@10Mb multi-mode FX-ST “twist lock” Combo Module

the 100Mb combo module with the exception of 10Mb speed at the ST fiber module.

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The

Each port has an Activity (ACT) LED indicating packets being received, a

segments. When installed in a Magnum 6K8-Series Managed Switch, the copper port

Each port has an Activity (ACT) LED indicating packets being received, a

The Magnum 6KP6-RJMST is a combo 6 port module of four RJ-45’s at

10/100 LED indicates the speed, if the LED is ON, 100Mbps if it is OFF, 10Mbps.

10/100 LED indicates the speed, if the LED is ON 100Mbps if it is OFF 10Mbps.

4 Port@ 10/100Mbps and 2 @100 Mb ST Fiber Port

10/100 LK

F/H ACT

4 FULL/HALF

2 6 TX RX TX LK RX LK

1 3 5 7

6KP6-RJMST,

ACT

F/H

LINK 2

i.e., typically 2km at full-duplex and 412m at half-duplex.

ACTIVITY

ACT

F/H

The ST-connector functions as

100m on each port and the fiber

segments. When installed in a

supports the standard distance

and dual speed copper ports.

a fiber optic transceiver to

Switch, the copper port

duplex and half-duplex.

Show 4 more labels / short text on this page
10/100 · dual-mode ST-type connectors · support 100BASE-FX network · Magnum 6K8-Series Managed
Page 52 of the GarrettCom 6K8 user manual — F/H
Page 52 · click to enlarge
Page 52
GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 52)
Fig. 36 · 3.1 Locating Magnum 6K8-Series Switches

hub to connect to the switch through 10Mb fiber ports. It supports distances according to

the 10Base-FL standard i.e, 2Km distance for multi-mode fiber. (Single-mode for 10Km

received, a Link (LK) LED indicating proper connectivity with the remote device when

5.2.1c 6KP4-FLSTFX, 2@10Mb & 2@100Mb multi-mode FX-ST “twist lock” Module

network to the Magnum 6K8-Series switch. They also provide a convenient way for the

5.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module

lit, and FDX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).

Each port has an Activity (ACT) LED indicating packets being

100Mb fiber. The 10Mb ST-fiber ports allow the user to connect their legacy 10Mb

1 ACTIVITY LINK 2

RX

TX RX LK

4 Port@ 10Mb ST Fiber Port

4 Port@ 10Mb ST Fiber Port

LK

6KP4-RJ10MST,

6KP4-RJ10MST,

2 6 T

switch. They also provide a convenient way for the half duplex

ACT

F/H

ACT

F/H

FULL/HALF

TX RX LK

TX RX LK

ACT

ACT

distance may be available as a special order).

F/H

F/H

their legacy 10Mb network

to the Magnum 6K8-Series

FLSTFX is a combo fiber

module with two 10Mb +

combine 4 ST-Fiber ports.

All four fiber ports are ST

default for 10Mb fiber and

100Mb Full duplex for the

Fiber ports. All four fiber

and configured as 10Mb

The 10Mb ST-fiber ports

allow the user to connect

as 10Mb Half-duplex by

is a 10Mb multi-mode

fiber module with 4 ST-

ports are ST connectors

Half-duplex by default.

fiber module and in

Show 4 more labels / short text on this page
The Magnum 6KP4-F10ST · connectors and configured · two 100Mb multi-mode · The Magnum 6KP4-
Page 53 of the GarrettCom 6K8 user manual — type, “snap-in”
Page 53 · click to enlarge
Page 53

While the functionality of these two modules is essentially the same, the 6KP6-

half duplex hub to connect to the switch through 10Mb fiber ports. Whereas the 100Mb

received, a Link (LK) LED indicating proper connectivity with the remote device when

5.2.2. 6KP6-RJMSC 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FXSC “snap-in” Fiber connector

distances according to the 10Base-FL standard i.e, 2Km distance for multi-mode fiber.

ST fiber module, allow to connect the 100Mb demand of Switch devices. It supports

lit, and FDX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).

4 Port@ 10/100Mbps and 2 @100 Mb SC Fiber Port

GarrettCom 6K8 — 4 Port@ 10/100Mbps and 2 @100 Mb SC Fiber Port diagram (page 53)
Fig. 37 · 4 Port@ 10/100Mbps and 2 @100 Mb SC Fiber Port

module of the 6K8-Series Switch supporting four Copper and two single-mode fiber

Each port has an Activity (ACT) LED indicating packets being

5.2.3 6KP6-RJSSC 4@ 10/100Mbps RJ-45 Ports and 2@100Mbps single-mode FX-SC-

RJMSC is equipped with an SC-type "snap-in" connector instead of an ST-type.

4 Port@ 10/100Mbps and 2 @100 Mb SSC Fiber Port

4 FULL/HALF

10/100 LK

F/H ACT

(Single-mode for 10Km distance may be available as a special order).

FDX / HDX and 10/100 operation, and the same face-plate lettering.

2 6 TX RX TX LK RX LK

6KP6-RJMSC,

1 3 5 7

6KP6-RJMSSC,

ACT

F/H

LINK 2

ACTIVITY

ACT

F/H

transceivers all in one module. This

is similar to the 6K6-RJMST. It has

module equipped with 4 10/100Mb

RJMSC is also a Combo 6 Port

RJ-45 ports along with 2 multi-

the same LEDs indicating port

activity (ACT), Link (LK), and

equipped with 4 dual speed

mode SC-type connectors. It

mode 100Mbps fiber optic

copper ports and 2 Single-

and Fiber functions in one

is also a Combo module

type, “snap-in”

connector

Show 5 more labels / short text on this page
10/100 · The Magnum 6KP6- · The Magnum 6KP6-RJSSC · through combining copper · provides an advantage
Page 54 of the GarrettCom 6K8 user manual — 3.1 Locating Magnum 6K8-Series Switches
Page 54 · click to enlarge
Page 54

The 6KP6-RJSSC, when installed in a Magnum 6K8-Series Switch operates on

copper at the 100m distance. The Fiber is single-mode and cable lengths can be as much

Link (LK) LED that indicates proper connectivity with the remote device when lit, and a

ports and 2 Single-mode (Long Reach) SC-type connectors. It provides a combination of

The Magnum 6KP6-RJ10ST is also a Combo module equipped with 4 dual speed copper

The 6KP6-RJ10ST, when installed in a Magnum 6K8-Series Switch has copper

The Magnum 6KP6-RJSSC is also a Combo module equipped with 4 dual speed copper

The 6KP6-RJSSC, when installed in a Magnum 6K8-Series Switch has copper

supporting the 100m distance and Fiber supporting single-mode fiber cable lengths of as

10/100 LED indicates the speed for the copper port, which is 100Mbps when the LED is

5.2.4a 6KP6-RJ10ST 4 @ 10/100 Mb copper port and 2@10Mbps multi- mode FL-ST-type, “twist-lock” connector

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The

distinguish the single-mode 6 K6-RJSSC from the multi-mode 6K6-RJMSC, the label

copper and Fiber functions in one module to the 6K8-Series Switches, supporting four

Link (LK) LED indicating proper connectivity with the remote device when lit, and a

ports and 2 multi-mode 10 Mb fiber ST-type connectors. It provides a combination of

copper and Fiber functions in one module to the 6K8-Series Switches, supporting four

Each port has an Activity (ACT) LED indicating packets being received, a

Each port has an Activity (ACT) LED indicating packets being received, a

FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). The

10/100 LED indicates 100Mbps speed when lit and at 10Mbps speed when off. To

5.2.4 6KP6-RJSSCL 4 @ 10/100 Mb copper port and 2@100Mbps single-mode FX-SC-type, “snap-in” connector

supporting the 100m distance and Fiber supporting multi-mode fiber cable allow to

connect the legacy network of 10Mb requirement in the network. Each port has an

Copper and two single-mode (Long-Reach) fiber network segments.

“Sgl. M.” is at the top of the faceplate of the 6K6-RJSSC.

Copper and two 10Mb of ST fiber network segments.

much as 40+ Km (see Power Budget, Section 4.5)

as 25+ Km (see Power Budget, Section 4.5)

ON and 10 Mb, when the LED is OFF.

network segments.

Page 55 of the GarrettCom 6K8 user manual — LINK
Page 55 · click to enlarge
Page 55

5.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factor

Magnum 6KP8-MTRJ is a multi-mode fiber optic 8-port module equipped with

The functionality of this 100BASE-FX multi-mode 8 Port module is essentially

with two different speeds. The top four ports of MTRJ Small form factor fiber support at

the same as the ST and SC-types. It has the same LEDs per port indicating port activity

The 6KP6-RJ10ST is a combo module with two different kinds of fiber flavor

When installed in a Magnum 6K8-Series Switch, the 100Mb MTRJ connector

proper connectivity with the remote device when lit, and a FDX/HDX LED indicating

speed for the copper port, which is 10Mbps when the LED is ON and 10 Mb when the

8 Port@ 100Mbps Multi-Mode Fiber port

5.2.5a 6KP6-MT10ST, 4 @100Mb multi-mode FX , MTRJ Small-Form- Factor and 2@ 10Mb Multi-mode ST-Fiber port

100Mb full-duplex, whereas the bottom two ports multi-mode ST-Fiber support 10Mb

half-duplex. This combo module provides more flexibility to the user to connect their

supports fiber optic cable distances up to the IEEE-standard 100Mbps distance limits,

Activity (ACT) LED indicating packets being received, a Link (LK) LED indicating

i.e., typically 2km at full-duplex and 412m at half-duplex. The10Mb Multi-mode ST-

full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the

FULL/HALF 1 ACTIVITY

“small-form-factor”

ACT

F/H

ACT

F/H

ACT

F/H

ACT

F/H

F/H LK LK LK LK

1 3 5 7

2 4 6 8 LK

legacy 10Mbfiber as well as 100Mb to the Magnum 6K8-Series Switch.

6KP8-MTRJ,

typically 2km at full-duplex and 412m at half-duplex.

LINK

ACT

F/H

ACT

ACT

ACT

F/H

F/H

(ACT), Link (LK), and FDX or HDX operation.

an RJ-45 port, but it is black in

and ease of connection make it

connectivity. When installed in

a Magnum 6K8-Series Switch,

distances up the IEEE-standard

connector. It looks almost like

color. The MT-RJ’s small size

100Mbps distance limits, i.e.,

a good choice for 100Mbps

it supports fiber optic cable

LED is OFF.

a small-form-factor MTRJ-type · “fiber-to-the-desktop” Ethernet

Page 56 of the GarrettCom 6K8 user manual — F/
Page 56 · click to enlarge
Page 56
GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 56)
Fig. 38 · 3.1 Locating Magnum 6K8-Series Switches

Fiber connector supports the standard fiber optic distance limit of 2Km at Full and Half-

3 2 4 6 8 LK

5.2.7 6KP8-MLC, 8 ports @ 100Mbps multi-mode LC connector SmallForm Factor

Magnum 6KP8-MLC is a eight-

When installed in a Magnum 6K8-Series

The functionality of this 100BASE-FX multi-mode 4 port module is

5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX , MTRJ Small-Form-Factor

4 Port@ 10/100Mbps & 4 port @ 100Mbps

100Mbps distance limits, i.e., typically

wiring closets while providing the advantage of “future-proof” fiber optic technology.

The cable end is a “plug-in” connector with both fiber strands terminated in

one housing that cannot be improperly inserted. Each port has an Activity (ACT) LED

“small-form-factor” used primarily in

100Mbps fiber-to-the-desktop links.

The compact size of the LC Connector reduces the size of wiring panels in

essentially the same as the ST and SC-types. It has the same LEDs per port

port multi-mode fiber LC connector

Switch, it supports fiber optic cable

2km at full-duplex and 412m at half-

distances up to the IEEE-standard

indicating port activity (ACT), Link (LK), and FDX or HDX operation

standard distances as mentioned on 5.2.3. and the LEDs also act similarly.

6KP8-45MT

duplex.

8-Port@ 100Mbps multi-mode LC fiber port

FULL/HAL 1 ACTIVIT

copper and fiber (Small Form Factor)

equipped with 4 10/100 RJ-45 ports

ACT

F/H

ACT

F/H

ACT

F/H

ACT

F/H

MTRJ type ports. The small size of

advantage of placing more ports on

When installed in a Magnum 6K8-

Module is a combo module with

one module. The 6KP8-45MT is

2 4 6 LK LK LK

2 4 6 LK LK LK

MTRJ connectors provides an

Series Switch, it supports the

and 4 MTRJ fiber ports.

LINK

ACT

ACT

ACT

duplex both.

ACT

F/

F/

F/

F/

Multi-Mode Fiber port · The Magnum 6KP8-45MT

Page 57 of the GarrettCom 6K8 user manual — Multi -Mod LC Fiber port
Page 57 · click to enlarge
Page 57

allows an advantage of having

with 4 10/100 RJ-45 ports and

When installed in a Magnum 6K8-Series Switch, it supports the standard distances as per

indicating packets being received, a Link (LK) LED indicating proper connectivity with

the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit

module with a combination of

copper and Fiber (Small Form

The 6KP8-45LC is equipped

small size of LC connectors

3 F/H ACT

cable connections. The 6KP8-RJ45 module is equipped with a Media Dependent Auto-

5.2.8 6KP8-45LC, Combo 4@ 100Mbps multi-mode -LC small-form factor and 4@ 10/100 Mbps RJ-45 Connector

45LC Module is a combo

Factor) LC type ports. The

more ports on one module.

4 LC ( Small form factor)

10/100 LK 1

Crossover (MDI-X) switch, which controls all ports for cascaded connection. This

multi-mode fiber ports.

The 6KP8-RJ45 module supports Ethernet twisted pair segments of any

4 FULL/HALF

mentioned on 5.2.8. and the LEDs also acts similarly as mentioned above.

2 4 6 8 F/ H ACT

10/100 LK

8 Port@ 10/100Mb Copper ports

1 3 5 7

5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port

6KP8-RJ45,

LINK 2

ACTIVITY

GarrettCom 6K8 — 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port diagram (page 57)
Fig. 39 · 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port

4 Port@ 10/100Mbps & 4 port @ 100Mbps

Multi -Mod LC Fiber port

equipped with an eight-port

RJ-45 connector, and offers

minimize emissions and will

shielded twisted pair (STP)

(or half-duplex when off).

10/100 full / half-duplex

on each port. The RJ-45

connector is shielded to

twisted pair (UTP) and

standard length. It is

Show 4 more labels / short text on this page
The Magnum 6KP8- · 10/100 · auto-negotiating capability · allow both unshielded
Page 58 of the GarrettCom 6K8 user manual — F/H
Page 58 · click to enlarge
Page 58

Auto-crossover (MDIX), which allow the RJ-45 ports to automatically Link with any RJ-

feature eliminates the need for a special twisted pair crossover cable when connecting to

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off), and a

5.2.10 6KP8-45-2MT, 6@ 10/100Mbps RJ-45 and 2@100Mb multi-mode FX , MTRJ Small-Form-Factor

5.2.10a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor

The Magnum 6KP8-45SLC eight port Module is a combo module with copper

100Mb MTRJ fiber ports. When installed in a Magnum 6K8-Series Switch, it supports

Each port has an Activity (ACT) LED indicating packets being received, a

Link (LK) LED that indicates proper connectivity with the remote device when lit, a

10/10 L 1

3 2 4 6 LK

6 Port@10/10Mbps & 2 port @100Mb Multi-Mode Fiber port

4 FULL/HALF

the standard distances as mentioned on 5.2.3. and the LEDs also act similarly.

F/H AC

ACT

F/H

ACT

F/H

“10/100” LED indicating 100Mb when lit (or 10 Mbps when off).

LINK 2

6KP8V6KP8-45-2MT

ACTIVITY

45 device and eliminate the use of cross-over cable.

and fiber (Small Form Factor) LC type fiber ports.

F/H

45-2MT eight port Module is a

combo module with copper and

sizes of MTRJ connectors give

fiber ports on one module. The

6KP8-45-2MT is equipped with

six 10/100 RJ-45 ports and two

an advantage of placing more

MTRJ type ports. The small

fiber (Small Form Factor)

a hub or another switch.

10/100 · 10/100 · The Magnum 6KP8-

Page 59 of the GarrettCom 6K8 user manual — 6KP8-45-2SLC
Page 59 · click to enlarge
Page 59

removing the transceiver, press the clips on either side of the transceiver at the same time

GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 59)
Fig. 40 · 3.1 Locating Magnum 6K8-Series Switches

The Magnum GBIC-SXSC is a multi-mode Gigabit fiber connector

supports cable distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e.,

The GBIC transceiver has been offered in the modular slot with multiple options as per

the user requirement. The two Giga port has been offered as GBPM-2OTX (fiber or RJ-

Each port has an Activity (ACT) LED indicating packets being received and a

6KP8V6 Port@ 10/100Mbps & 2 port @ 100Mbps

5.2.11 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector

45), whereas the single Gigabit module comes in two different flavor of G+2 (100Mb

equipped with SC type connectors and can be easily snapped in and out. The Gigabit

fiber ports are most popular as server-to-switch and switch-to-switch applications. It

The GBIC transceiver is fastened using snap-in clips. Insert the transceiver

(take care to insert it the right way up, arrows on top) until it clicks in space. While

Link (LK) LED indicating proper connectivity with the remote device when lit.

fiber ports) or G+4(10/100 RJ-45 ports) as shown in the above figure.

Single-Mode Fiber port (LC)

1@ 1000Mb Fiber SC + 4@10/ 100Mb

6KP8-45-2SLC

GarrettCom 6K8 — 6KP8-45-2SLC diagram (page 59)
Fig. 41

6KP8-45-2SLC is equipped with 6

When installed in a Magnum 6K8-

standard distances as mentioned on

The small sizes of LC connectors

10/100 RJ-45 ports and 2 Single-

provide an advantage of placing

more ports on one module. The

Series Switch, it supports the

5.2.4. and the LEDs also act

and pull the transceiver out.

550m at full duplex.

mode fiber ports.

similarly.

Page 60 of the GarrettCom 6K8 user manual — TX RX LK
Page 60 · click to enlarge
Page 60

with SC type connectors and can be easily snapped in and out. The Gigabit fiber ports are

The two Giga port has been offered as GBPM-2OTX (fiber or RJ-45), whereas the single

The Magnum GBIC-LXSC is a single-mode Gigabit fiber connector equipped

Gigabit module comes in flavor of G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber ports)

Each port has an Activity (ACT) LED indicating packets being received and a link (LK)

5.2.11a GBIC-LXSC Gigabit fiber (1000Mb), multi-mode SC Connector

most popular as server-to-switch and switch-to-switch applications. It supports cable

distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e., 10,25, 40 or

LED indicating proper connectivity with the remote device when lit.

70Km at full duplex, and depend upon the Gigabit modules used.

1@ 1000Mb Fiber SC + 2@ 100Mb SC

TX LK RX

ACT

F/

TX RX L

as shown below in the above figure.

TX RX LK

ACT

ACT

F/

F/

Page 61 of the GarrettCom 6K8 user manual — 6.1 Before Calling for Assistance
Page 61 · click to enlarge
Page 61

suggestions listed below prior to contacting your supplier. However, if you are unsure of

intended to help locate, identify and correct these types of problems. Please follow the

1. If difficulty is encountered when installing or operating the unit, refer back to

Series Switch product, it is recommended that the problem device be replaced

with a known good device. Verify whether or not the problem is corrected. If

not, go to Step 5 below. If the problem is corrected, the Magnum 6K8-Series

5. If the problem continues after completing Step 4 above, contact your supplier

performing as expected, do not attempt to repair the unit; instead contact your supplier

the Installation Section of the applicable chapter of this manual. Also check

3. Make sure that an AC power cord is properly attached to each Magnum 6K8-

of the Magnum 6K8-Series Switch unit or if unknown, contact GarrettCom,

to make sure that the various components of the network are interoperable.

4. If the problem is isolated to a network device other than the Magnum 6K8-

Magnum 6K8-Series Switch is a straightforward procedure (see INSTALLATION,

the procedures described in this section or if the Magnum 6K8-Series Switch is not

Series Switch unit. Be certain that each AC power cord is plugged into a

consistently high performance in all network environments. The installation of a

Should problems develop during installation or operation, this section is

2. Check the cables and connectors to ensure that they have been properly

impaired during installation. (About 90% of network downtime can be

functioning electrical outlet. Use the PWR LEDs to verify each unit is

All Magnum Ethernet products are designed to provide reliability and

Section 2.6); the operation is also straightforward and is discussed in Section 4.

connected and the cables/wires have not been crimped or in some way

Inc. by fax, phone or email (support@garrettcom.com) for assistance.

Switch and its associated cables are functioning properly.

for assistance or contact GarrettCom Customer Support.

attributed to wiring and connector problems.)

6.1 Before Calling for Assistance

6.0 TROUBLESHOOTING

receiving power.

Page 62 of the GarrettCom 6K8 user manual — 6.2 When Calling for Assistance
Page 62 · click to enlarge
Page 62

All returns for repair must be accompanied by a Return Material Authorization

4. A record of changes that have been made to your network configuration prior

d. Any particular application that, when used, appears to create the problem;

3. It is useful to include other network equipment models and related hardware,

including personal computers, workstations, terminals and printers; plus, the

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

GarrettCom will carefully test and evaluate all returned products, will repair products

number(s). Include the date(s) that you purchased the products from your

that are under warranty at no charge, and will return the warranty-repaired units to

the sender with shipping charges prepaid (see Warranty Information, Appendix A,

1. A complete description of the problem, including the following points:
2. An accurate list of GarrettCom product model(s) involved, with serial

to occurrence of the problem. Any changes to system administration

for complete details). However, if the problem or condition causing the return

Failure symptoms, including a full description of the problem.

6.3 Return Material Authorization (RMA) Procedure

(RMA) number. To obtain an RMA number, please use this URL -

Please be prepared to provide the following information.

cannot be duplicated by GarrettCom, the unit will be returned as:

Name and phone number of your contact person.

Please have the following information readily available:

Packing List Number (or Sales Order Number)

c. The components involved in the problem;

procedures should all be noted in this record.

a. The nature and duration of the problem;

various network media types being used.

No Problem Found.

b. Situations when the problem occurs;

Name of your company / institution

Serial Number (or Invoice Number)

6.2 When Calling for Assistance

supplier.

Your shipping address · Date of installation · Product name

Page 63 of the GarrettCom 6K8 user manual — POWER
Page 63 · click to enlarge
Page 63

sheet or bag for shipping protection. ( You may retain all connectors and this

1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic

material. This material may cause electro-static shock damage to the unit.

power source, for 24VDC, -48VDC and 125VDC option power input. The wide range of

CAUTION : Do not pack the unit in Styrofoam "popcorn" type packing

Each Magnum Model 6K8-Series Managed Switch (DC option) requires a DC

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

GarrettCom, Inc. warrants its products to be free from defects in materials

units under warranty. Testing and repair of product that is not under warranty will

Should you need to ship the unit back to GarrettCom, please follow these

replace components in the products that prove to be defective at no charge other

product has been damaged by misuse, misapplication, or as a result of service or

B1.0 SPECIFICATIONS FOR MAGNUM 6K8-SERIES SWITCHES, DC

GarrettCom reserves the right to charge for the testing of non-defective

This warranty will not be effective if, in the opinion of GarrettCom, the

Please complete the warranty card as this acts as a product registration,

Magnum 6K8-Series models, for –48V and 24V DC & 125VDC Power input

and workmanship for a period of three (3) years from the date of shipment by

than shipping and handling, provided that the product is returned pre-paid to

inspecting any product returned for warranty repair which turns out not to be

During this warranty period, GarrettCom will repair or, at its option,

3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to:

GarrettCom reserves the right to make a charge for handling and

and mail it to GarrettCom within two weeks of your purchase.

APPENDIX B : Internal DC Power Supply Options

APPENDIX A: WARRANTY INFORMATION

6.4 Shipping and Packaging Information

47823 Westinghouse Dr.

Attn.: Customer Service

modification other than by GarrettCom.

GarrettCom, Inc.

result in a customer (user) charge.

Installation Guide.)

GarrettCom.

GarrettCom.

instructions:

faulty.

POWER

Fremont, CA 94539-7437

Page 64 of the GarrettCom 6K8 user manual — B3.0 APPLICATIONS FOR DC
Page 64 · click to enlarge
Page 64
GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 64)
Fig. 42 · 3.1 Locating Magnum 6K8-Series Switches

applied to the two inputs. It protects the Switch from incorrect DC input connections. An

The manual power “On-Off” Switch (optional) is used for powering the unit on

into the switch. This allows the Switch to operate only whenever DC power is correctly

GND GND CHASSIS

B2.0 -48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION

incorrect polarity connection, for example, will neither affect the Switch, its internal

environments. The 24VDC, -48VDC or 125VDC power input provides an Ethernet

HUB POWER SWITCH

SUPPLY

FUSE +

power input qualifies this product for use in 24VDC, -48VDC as well as 125VDC

GNDTerminal for “earth” or ground wire connection to the 6K8-Series chassis

networking product utilizing a special type of power supply with a proven high-

power supply, nor will it blow the fuse in the internal power supply.

Power Consumption25 watts max., for fully loaded (fiber ports)

(24V, -48V, 125V)DC 8 watts typical for all (RJ-45 Ports)

Input current0.125Amps max.(for all Fiber ports)

and off when it is placed into or taken out of service.

DC Power Terminals : “+”, “ - ” , internally floating

Input current0.6Amps max.(for all RJ-45 ports)
Input current1.2Amps max.(for all Fiber ports)
Input current0.4Amps max.(for all RJ-45 ports)
Input current0.7Amps max.(for all Fiber ports)
Input current0.1Amps max.(for all RJ-45 ports)

A+

A-

reliability record to fulfill the DC requirement.

POWERED ETHERNET SWITCHES

Magnum 6K8-Series Switches are

Input Voltage-36 to -70 VDC (-48VDC)
Input Voltage88 to 300 VDC (125VDC)

easily installed in a variety of applications

power is used as the primary power source.

input line behind the two external power

where -48VDC, 24, or 125VDC or 5VDC

Input Voltage18 to 36 VDC (24VDC)

connection terminals, so that the power

B3.0 APPLICATIONS FOR DC

The DC power configuration capability

using diodes inside on each DC power

from an external source can only flow

The -48VDC, 24VDC and

125VDC power options are designed

DC terminal · block

Page 65 of the GarrettCom 6K8 user manual — B4.0 6K8-SERIES, -48V, 24, 125 OR 5VDC INSTALLATION
Page 65 · click to enlarge
Page 65

The –48VDC solution is particularly useful inthe telecommunication industry, where it is

common for facilities to operate on -48VDC power. Such companies include regular and

facilities often use a battery backup system to maintain operations in the event of a power

generating plants, etc. The 24VDC applications are mainly in the Industrial environment,

located on the left front of the unit and is equipped with three (3) screw-down lead posts.

The connection procedure is straightforward. Simply insert the DC leads to the

where it is common for facilities to operate on 24VDC or 125VDC power. The 125VDC

such as factory floor, HVAC equipment, military equipment, etc. The 5VDC options are

The power terminals are identified as positive (+) and negative (-), and they are floating

and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead

communication companies. In addition, many high availability equipment services,

The 24V and 125VDC options are particularly useful in the Industrial environment,

Series Switch. The DC terminal block on the Magnum 6K8-Series Managed Switch is

(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely

Figure C5.0-48VDC, wiring connections to the External Terminal Block on a

24VDC/125VDC/5VDC leads) to the DC power terminal block on the Magnum 6K8-

inside the unit so that either may be grounded by the user if desired. The chassis is

Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground

will connect to the post labeled “+ve” and the rest to the “-ve”. The GND can be

wireless telephone service providers, Internet Service Providers (ISPs) and other

such as broadcasters, publishers, newspaper operations, brokerage firms and other

options are mainly used in power utilities, such as electrical substations, electrical

failure. It is also frequently used for computer system backup, management and

This section describes the proper connection of the -48VDC leads (or

B4.0 6K8-SERIES, -48V, 24, 125 OR 5VDC INSTALLATION

When power is applied, the green PWR LED will illuminate.

mainly used for military or Industrial factory floor applications.

power supply in switches with a proven track record.

an Ethernet networking solution utilizing a special

operations monitoring equipment.

“earth” or ground (GND).

hooked up at the last.

tightened.

Magnum 6K8 -48VDC · provides

Page 66 of the GarrettCom 6K8 user manual — B7.0 TROUBLESHOOTING
Page 66 · click to enlarge
Page 66

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage

1. Minimum 18AWG cable for connection to a Centralized DC power source. 2. Minimum 14AWG cable for connection to a earthing wiring. 3. Use only with Listed 10 A circuit breaker provided in building installation. 4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.
5. Fastening torque of the lugs on the terminal block: 9 inch-pound max. 6. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rac,k at least 4 inches apart, with the first one located
GNDTerminal for “earth” or ground wire connection to the hub chassis
GNDTerminal for “earth” or ground wire connection to the hub chassis

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

Similarly to order the optional 24VDC or 125VDC industrial specific power

DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”

supply factory installed, add a suffix of “24VDC” or “125VDC” after the product ‘s

C1.0 SPECIFICATIONS - FOR MAGNUM 6K8-SERIES FIBER SWITCH

so the user may elect to Ground either + or = terminal to suit the customer’s use.

24VDC and 125VDC power supply is identical to that of the standard AC-powered

standard model #. ExampleMagnum 6K8-Series24VDC, Magnum 6K8-Series-

Operation of Magnum 6K8-Series Switches with the optional -48VDC,

Power Supply (Internal, -48VDC Dual-Source, model # Dual-Src-48V)

Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)

lead from 48V or –48V supply must be connected to the post labeled “+”.

APPENDIX C: Internal DC Dual-Source Power Option

InputTwo separate sources, each at 36 - 70 VDC
InputTwo separate sources, each at 18 - 36 VDC

Please refer to Section 6.0 for troubleshooting

B4.1 UL Requirements for DC-powered units

within 6 inches of the terminal block.

B7.0 TROUBLESHOOTING

B5.0 OPERATION

125VDC.

models.

Page 67 of the GarrettCom 6K8 user manual — B+
Page 67 · click to enlarge
Page 67

the Magnum 6K8-Series Fiber Switches Installation and User Guide, including Appendix

supply, all specifications and configuration options for the Magnum 6K8-Series -48VDC,

24VDC and 125VDC models with this Dual-Source option are identical to those listed in

C2.0 MAGNUM 6K8-SERIES, with -48VDC, 24VDC and 125VDC Dual-Source

d) Reverse polarity connections, if they should accidentally occur on either input, will not damage

GNDTerminal for “earth” or ground wire connection to the hub chassis

125VDC Dual-Source power supply are designed for installations where a battery plant

Refer to the main sections of this Installation and User Guide for a detailed description

a) The Switch unit can receive power from either input, “A” or “B”. The hub will normally draw

DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”

FUSE +

GND CHASSIS

b) The Switch unit will not allow power to flow from a higher voltage input to a lower voltage

c) When one correct DC input is present, the Switch will receive power if the other DC input is

the Switch or power supply internally (nor will it blow the fuse in the internal power supply)

With the exception of the dual DC input power connections and the power

The functionality of the Magnum 6K8-Series Switch -48VDC, 24VDC and

125VDC Dual-Source Option units is identical to the standard AC-powered models.

SUPPLY A+

HUB

GND

can only flow into the unit. This allows the unit to operate whenever DC power is

Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-125V)

The 6K8-Series-Switch models with the internal -48VDC, 24VDC and

is the power source, and where two separate power sources are utilized in order to

C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN

absent, or even if it is connected with reverse polarity or shorted or grounded.

C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION

InputTwo separate sources, each at 88 - 300 VDC

its power from the DC source with the highest voltage at a given time.

input, i.e. the two DC power sources are not mixed together by the hub.

increase operational uptime and to simplify maintenance.

correctly applied to either or both of the two inputs

B+

A-

B-

B “Internal DC Power Supply Option”

of the Magnum 6K8-Series Switches.

The Dual-Source DC power

option is designed using diodes inside

of the chassis on each DC power input

external power connection terminals)

so that power from an external source

line. A diode is placed in each of the

four input lines (behind the four

option (OPTIONAL)

Page 68 of the GarrettCom 6K8 user manual — C5.0 INSTALLATION
Page 68 · click to enlarge
Page 68
GarrettCom 6K8 — 3.1 Locating Magnum 6K8-Series Switches diagram (page 68)
Fig. 43 · 3.1 Locating Magnum 6K8-Series Switches

Src, wiring connections to the External Terminal Block on a Magnum 6K8 -48VDC

1. Minimum 18 AWG cable for connection to a Centralized DC power source. 2. Minimum 14 AWG cable for connection to earthing wiring. 3. Use only with Listed 10 A circuit breaker provided in building installation. 4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.

determine the lead which is more “+ve potential”. The more “+ve” voltage lead from

The connection procedure is straightforward. Simply connect the DC leads to

The 24VDC & 125VDC terminal block on Magnum 6K8-Series’s is similar to

e) The Switch will not receive power (and will not work) when both inputs are simultaneously

negative (A-), and the secondary power terminals as negative (B-), positive(B+). The

terminal block for the 24VDC and 125VDC are similar. Figure C5.0: -48VDC-Dual-

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 125VDC,

always use a digital voltmeter to measure the output voltage of the power supply and

the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground

(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely

The following must be adhered to in order to conform to UL requirements:

because of the blocking action of the diodes. This is true even if one input connection is

This section describes the proper connection of the -48VDC, 24VDC and

chassis “earth” or ground (GND) is a threaded post with a #6 nut. The Dual Source

so the user may elect to Ground either + or = terminal to suit the customer’s use.

5. Fastening torque of the lugs on the terminal block: 9 inch pound max.

48V or –48V supply must be connected to the post labeled “+”.

125VDC power terminal block on the Magnum 6Ks Switch

reversed while the Switch is operating from the other source.

The -48VDC terminal block on the Magnum 6K8-Series

125VDC dual source leads to the -48VDC, 24VDC &

The primary terminals are identified as positive (A+),

that described in the –48VDC information above.

absent or are both incorrectly connected.

located on the left front of the unit

Switch, as shown in Fig C5.0 is

C5.0 INSTALLATION

and is equipped with five (5)

screw-down lead posts.

C5.1 UL Requirements

as shown in Fig.

tightened.

Block (Dual-Source) · DC Terminal

Page 69 of the GarrettCom 6K8 user manual — C7.0 OPERATION
Page 69 · click to enlarge
Page 69
6. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located

Similarly, order the “Dual –source 24VDC” or “Dual-source 125VDC” as a

Operation of the Dual-Source Magnum 6Ks-48VDC, 24VDC and 125VDC

To order the optional Dual-Source -48VDC power supply factory installed,

order “Dual-Src48V” as a separate line item following the product model.

Dual-Src-48V for the regular DS model

ExampleMagnum 6K8 -24VDC

Switch models are identical to that of the standard models.

separate line item following the product model.

C6.0 ORDERING INFORMATION (Optional)

ExampleMagnum 6K8 -48VDC

within 6 inches of the terminal block.

C7.0 OPERATION

Ask about the GarrettCom 6K8

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom 6K8

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom 6K8 manual PDF

69 pages·993 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…