Magnum 6K32T & 6K32TRCp.1Hardware User Manualp.1Installation and User Guidep.1Managed Switchp.16K32TRCp.16K32Tp.1Magnum ™ 6K32T & 6K32TRCp.2Managed Switch Hardwarep.2Phone (510) 438-9071p.34.4 Flow-control, IEEE 802.3x standard..................................................49p.55.2.10b. New PoE(Power Inside), model PI6KP8-45RJ (MDIX) .................60p.55.2.12a GBPM-2OTX (Two Gigabit option)......................................63p.55.2.12b GBIC-LXSC Gigabit fiber (1000Mb), multi-mode SC .........64p.56.3 Return Material Authorization (RMA) Procedure..............................66p.56.4 Shipping and Packaging Information.................................................67p.5APPENDIX A: WARRANTY INFORMATION .........................................67p.5APPENDIX B : INTERNAL DC POWER SUPPLY OPTIONS.................68p.5APPENDIX C: INTERNAL DC DUAL-SOURCE POWER OPTION ......71p.5APR, 07p.6INDUSTRIAL NETWORKING PRODUCTSp.6"DESIGNED AND MANUFACTURED IN THE USA"p.6The Magnum Linep.6OVERVIEWp.61.1 Technical Specificationsp.71.0 SPECIFICATIONSp.7Relay Alarm Contact (Optional)p.9Cooling Method-p.9(6K32TRC)p.9Magnum Managed Switchp.10MODEL DESCRIPTIONp.106K32T/6K32TRC PoE Modules with 48VDC Power Insidep.122.1 Inspecting the Package and Productp.142.0 Introductionp.142.2 Product Description - Magnum 6K32TRC Managed Switchp.15(CLI)p.162.2.1a Magnum 6K32T Managed Switch Chassisp.17ACTp.18F/Hp.182.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb fiberp.182 4 6 8 LK LK LK Lp.18ACp.18F/H LK LK LK LKp.182 4 6 8 LK LK LK LKp.1810/100 LKp.192 4 6 8 F/ H ACTp.19F/H ACTp.192.2.3 Eight-Port Copper Module, 6K8-RJ45 (MDIX)p.194 FULL/HALFp.20PI6KP8V-45RJp.20LK/ACT 2p.202.2.4 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45 and 2@100Mbp.212 6 TX RX TX LK RX LKp.21fiberp.214@RJ-45 + 2@ 100Mb ST or SCp.212.2.5 Four-Port 10 Mb mm Fiber ST Modulesp.22TX RX LKp.22LKp.222 6 Tp.22F/ ACTp.2310/100 Lp.23TX RX ACp.23F/p.232.2.6 Gigabit (1000Mbps) port modulesp.23TX LK RXp.23TX RX Lp.232.2.7 Packet Prioritization, 802.1p QOSp.242.2.8 Frame Buffering and Flow Controlp.242.2.9 Managed Network Software (MNS-6K) for Magnum 6K32T &p.252.3 Features and Benefitsp.262.4 Applicationsp.27Datap.28100Mbps Full duplex Fiber forp.28UPLINKp.28LK/RX PORTp.28COL 10p.28COL 100p.28PWRBRp.28100Mb Serversp.28Example 3 Redundant Application (6K32TRC)p.29Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2p.31
Page 1 of the GarrettCom 6K32T user manual — 6K32TRC
Page 1 · click to enlarge
Page 1
GarrettCom 6K32T — Magnum 6K32T & 6K32TRC diagram (page 1)
Fig. 1 · Magnum 6K32T & 6K32TRC
GarrettCom 6K32T — Magnum 6K32T & 6K32TRC diagram (page 1)
Fig. 2 · Magnum 6K32T & 6K32TRC

Magnum 6K32T & 6K32TRC

Hardware User Manual

Installation and User Guide

Managed Switch

6K32TRC

6K32T

Page 2 of the GarrettCom 6K32T user manual — Managed Switch Hardware
Page 2 · click to enlarge
Page 2

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide(05/07)

GarrettCom, Magnum, Personal Switch, S-Ring, Link-Loss-Learn, Converter

Switch and Convenient Switch are trademarks and Personal Hub is a registered

experienced with Magnum 6K32T & 6K32TRC Switch products, consult

contains no user serviceable parts. Attempted service by unauthorized

personnel shall render all warranties null and void. If problems are

GarrettCom, Inc. reserves the right to change specifications, performance

Copyright © 2007 GarrettCom, Inc. All rights reserved. No part of this

Magnum ™ 6K32T & 6K32TRC

publication may be reproduced without prior written permission from

Managed Switch Hardware

Installation and User Guide

UL is a registered trademark of Underwriters Laboratories

Section 6, Troubleshooting, of this User Guide.

Part #84-00138 (Rev. B)

characteristics and/or model offerings without notice.

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

Printed in the United States of America.

trademark of GarrettCom, Inc.

GarrettCom, Inc.

Trademarks

Page 3 of the GarrettCom 6K32T user manual — Phone (510) 438-9071
Page 3 · click to enlarge
Page 3

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide(05/07)

This equipment generates, uses and can radiate frequency energy and if

not installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested

and found to comply with the limits for a Class A computing device in accordance

with the specifications in Subpart J of Part 15 of FCC rules, which are designed to

provide reasonable protection against such interference when operated in a

commercial environment. Operation of this equipment in a residential area is

likely to cause interference, in which case the user at his own expense will be

Cet appareil respecte toutes les exigences du Réglement sur le matériel du

Please use the mailing address, phone and fax numbers and email address listed

required to take whatever measures may be required to correct the interference.

This Class A digital apparatus meets all requirements of the Canadian

Websitehttp://www.GarrettCom.com

Radio Frequency Interference Statement

email support@garrettcom.com

below: GarrettCom, Inc.

47823Westinghouse Dr. Fremont, CA 94539-7437

Phone (510) 438-9071

Interference-Causing Equipment Regulations.

RegulatoryUL60950 Voltage Range:

Canada. Cet appareil est Classe A.

18-36VDC24vdc option 38-60VDC:60vdc option 100-150VDC:125vdc option 100-240VacAC option Test Temp.: 40˚C
Show 4 more labels / short text on this page
Federal Communications Commission · Fax (510) 438-9072 · Canadian Emission · Contacting GarrettCom, Inc
Page 4 of the GarrettCom 6K32T user manual — Phone (510) 438-9071
Page 4 · click to enlarge
Page 4
Page 4 of the GarrettCom 6K32T user manual — Phone (510) 438-9071
Page 5 of the GarrettCom 6K32T user manual — 5.2.12a GBPM-2OTX (Two Gigabit option)......................................63
Page 5 · click to enlarge
Page 5

4.4 Flow-control, IEEE 802.3x standard 49

5.0 6K32T & 6K32TRC MANAGED SWITCH PORT MODULES 49 5.1 Inspecting the Package and Product 50

5.2 6KPM Module Description 50 5.2.1 6KP6-RJMST multi-mode FX-ST “twist lock” Module 51 5.2.1a 6KP6-RJ10ST multi-mode FX-ST “twist lock” Combo 51 5.2.1b 6KP4-F10ST multi-mode FX-ST “twist lock” Module 52 5.2.1c 6KP4-FLSTFX multi-mode FX-ST “twist lock” Module 52 5.2.2. 6KP6-RJMSC multi-mode FX-SC “snap-in” Fiber connector 53 5.2.3 6KP6-RJSSC Mbps single-mode FX-SC-type, “snap-in” 54 5.2.4 6KP6-RJSSCL FX-SC-type, “snap-in” connector 54 5.2.4a 6KP6-RJ10ST FL-ST-type, “twist-lock” connector 55 5.2.5 6KP8-MTRJJ Small-Form-factor 55 5.2.5a 6KP6-MT10STmode FX Factor 56 5.2.6 6KP8-45MT MTRJ Small-Form-Factor 57 5.2.7 6KP8-MLC LC connector Small- 57 5.2.8 6KP8-45LC 10/100 Mbps RJ-45 Connector 58 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port 58 5.2.10a. New PoE (Power Pass-through)P6KP8V-RJ45 (MDIX) 59

5.2.10b. New PoE(Power Inside), model PI6KP8-45RJ (MDIX) 60

5.2.11 6KP8-45-2MT MTRJ Small-Form-Factor 62 5.2.11a 6KP8-45-2LC single-mode FX , LC Small-Form-Factor 62 5.2.12 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC 62

5.2.12a GBPM-2OTX (Two Gigabit option) 63

5.2.12b GBIC-LXSC Gigabit fiber (1000Mb), multi-mode SC .........64

5.2.13 6KM-BLNK ...............................................................................64 6.0 TROUBLESHOOTING.......................................................................65

6.1 Before Calling for Assistance.............................................................65

6.2 When Calling for Assistance..............................................................66

6.3 Return Material Authorization (RMA) Procedure..............................66

6.4 Shipping and Packaging Information.................................................67

APPENDIX A: WARRANTY INFORMATION .........................................67

APPENDIX B : INTERNAL DC POWER SUPPLY OPTIONS.................68

APPENDIX C: INTERNAL DC DUAL-SOURCE POWER OPTION ......71

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide(05/07)

Rev C 05/07: SFP fiber info added and Typo error updated on Temp.

Rev A 08/04 : This revision is the initial release of the 6K32T manual.

Rev A 02/05Minor updates and tweak on LC connector diagram
Rev C 10/06Included 6K32TRC and PoE Modules
Rev A 05/05Minor updates, Auto-Cross(MDIX)
Rev B 12/05Updated Gigabit options

Revisions

Page 6 of the GarrettCom 6K32T user manual — OVERVIEW
Page 6 · click to enlarge
Page 6

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide(05/07)

GarrettCom, Inc. offers the premium-quality Magnum™ line of

INDUSTRIAL conectivity products with industry-standard functionality and

built-in fiber configurability. Magnum products are designed for use in

demanding Industrial Grade, Carrier Class, POWER UTILITY and OEM

4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto-negotiating

Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed and mixed-media

mP62 and P62F “Outdoor” Ethernet SwitchES, for temperature uncontrolled locations, 6 10/100

Personal Hubs, 10Mb series 8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-

6K-Series Managed Field Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports, mix-and

APR, 07

Media Converters, 10Mb and 100Mb series, All media combinations, incl. fiber ST, SC, mm.,

Personal Hubs, 100Mb or 10/100Mb 8-port, with 2 switched ports (1 fiber built in)

INDUSTRIAL NETWORKING PRODUCTS

"DESIGNED AND MANUFACTURED IN THE USA"

The Magnum Line

applications where reliability is a primary consideration.

Stackable Concentrators, SNMP optional, 13-Ports

OVERVIEW

Dual Speed 8-port and 16-port, 10/100 auto-sensing HUBS

Repeater Port Modules (RPMs), 6 types for Ethernet media

Mixed-Media Fiber Hub, 16-port, 10/100 auto-sensing

The “X-line” of configurable MiXed Media products:

DX-Series Serial Device Routers, Ethernet and Serial

port and 4 or 5-Port Personal Hubs, w/ man. up-link sw.

match. Features SFF fiber and DC power in 1U units.

and 2 100Mb fiber ports, can be connected in strings

8 port dual-speed, Auto-negotiable with fiber option

Mini-Concentrators, 7 Ports, Repeaters, 2-Ports

COAX Transceivers, 10Mb series

types, full switching performance.

Personal Switches, 10/100Mb

full switching performance.

single mode

Page 7 of the GarrettCom 6K32T user manual — 1.0 SPECIFICATIONS
Page 7 · click to enlarge
Page 7

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

Switching Processing TypeStore and Forward with IEEE 802.3x full-

100BASE-FX, full-duplex, single-mode - 20.0 km (6K32T ft) 100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft)

Unshielded twisted pair - 100 m (328 ft)

10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)

10BASE-FL single-mode fiber optic - 10 km (32,810 ft)

10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)

100BASE-TX (CAT 5 UTP) - 100 m (328 ft)

100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft)

Packet buffer size240KB for 10/100 and 120KB for 1000Mb

100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft)

100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)

Shielded twisted pair - 150 m (492 ft)

Shielded twisted pair - 150 m (492 ft)

Address Table Capacity4K node, self-learning with address aging

Throughput with 16 10/100 and 4 Glink max- 8.33M pps (Transmit)

15 µs + packet time (10 to 10 Mbps, and 10 to 100Mbps)

IEEE 802.3z1000BASE-X Ethernet(Auto-negotiation)

Maximum Standard Fast Ethernet Segment Lengths:

IEEE 802.1xPort based Network access control
Ethernet V1.0/V2.0 IEEE 802.310BASE-T,
IEEE 802.3adLink Aggregation (Trunking)

Maximum 10 Mbps Ethernet Segment Lengths

duplex flow -control, non-blocking

Latency5 µ s + packet time (100 to 100Mbps)
IEEE 802.1wRapid Spanning tree protocol
Data Rate10Mbps,100Mbps and 1000Mbps
IEEE 802.3u100Base-TX, 100BASE-FX

Back plane- 2.66Gb/s per slot

IEEE 802.3ab1000BASE-X Ethernet
IEEE 802.1dSpanning tree protocol
Gigabit Ethernet1,488,000 pps

Filtering / Forwarding Rate:

Network Standards and Compliance

Fast Ethernet148,800 pps
IEEE 802.1pPriority protocol
IEEE 802.1qVLAN Tagging

1.1 Technical Specifications

IEEE 802.3xFlow Control

Ethernet:14,880 pps

1.0 SPECIFICATIONS

Performance

Page 8 of the GarrettCom 6K32T user manual — 1.1 Technical Specifications
Page 8 · click to enlarge
Page 8

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

with adjacent manual ON-OFF switch (optional if no Alarms Cont.)

DB-9 for RS-232 “ null-modem “ cable (sometimes called an X-modem cable)

UL 60950 “Component Parts” temp. ratings: 140° F (60°C) (6K32TRC)

UL 60950 “Component Parts” temp. ratings: 130° F (55°C) (6K32T)

EnclosureRugged High strength metal. Suitable for stand-alone

1000BASE-T (CAT5E or higher is recommended) - 100 m 1000BASE-SX, full-duplex, multi-mode(62.5µm cable) - 220m 1000BASE-SX, full-duplex, multi-mode(50µm cable) - 550m 1000BASE-LX, full-duplex, single-mode(62.5µm cable) -5Km Fiber connector types supported:

Conformal Coating (Humidity Protection) option: Request quote

30 watts for a fully-loaded copper only model

AC Power ConnectorIEC-type, male recessed at rear of chassis,

IEC 60068 “Type Test” ratings:- -40°to 185°F (-40°to 85°C)

Ambient Relative Humidity5% to 95% (non-condensing)

Maximum Standard Gigabit Ethernet Segment Lengths:

-48VDC Power Input Voltage-36 to -70 VDC
Power Consumption45 watts max (with fiber module)
LKSteady ON when media link is operational
Dimensions1.70in. H x 17.0in. W x 9.0in. D

4.32cm H x 43.2cm W x 22.9cm D Cooling method: Fan cooled, @ 3@ 7 cfm ea.

Altitude-200 to 13,000 ft. (-60 to 4000m)
Input Voltage100 to 240 VAC (auto-ranging)

LC-type Small Form Factor (SFF)

OFF = Half-Duplex Mode

Input Frequency47 to 63 Hz (auto-ranging)
FDX/HDXON = Full-Duplex Mode

MTRJ-type Small Form Factor (SFF)

ACTON with receiver port activity

Fuse required for replacement- 1 Amps

100/10ON = 100Mbps speed OFF = 10 Mbps

DC Power Supply (Options)

LEDsPer Port
Show 8 more labels / short text on this page
or rack-mounting · Management Console connector · ST-type (twist-lock) · Operating Environment · Power Supply (Internal) · SC-type (snap-in) · GBIC modules · Packaging
Page 9 of the GarrettCom 6K32T user manual — Cooling Method-
Page 9 · click to enlarge
Page 9

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

For (Optional) DC internal power supplies at –48VDC, 24VDC and 125VDC,

The Alarm Contact option is offered as a configuration option. The alarms can be

The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45

initiated through two normally closed Form-C contacts, one loss of power alarm

ports., and eliminate the use of cross-over cable between the devices. Also

port-specific user settings (such as FDX or HDX, copper 10/100 speed) can

http://www.garrettcom.com/techsupport/insertion_guides/6k32trcg.pdf (6K32)

including Dual Source options (for continuity of operation when either of the DC

See also Note for Power Substations in Section 3.2.4, 3.6.1, and 5.2.9

IEC61850 EMC and Operating Conditions Class C for Power Substations

6K32TRC- Convection cooled (No fans) Static Thermal design techniques

UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15, Class A

IEEE 1613 Environmental Standard for Electric Power Substations.

http://www.garrettcom.com/techsupport/insertion_guides/6k32trccg.pdf

125VDC Power and 100VDC Input Voltage : 88 to 300VDC Fuse Required – 1Amps

NEBS L3 and ETSI Compliant, NEMA TS-2 for traffic control

WarrantyThree years, return to factory Made in USA
Power Consumptionsame as for AC models, see above

and one software alarm through user selectable software traps.

For a Configuration Guide, see the GarrettCom web site at

24VDC Power Input Voltage20 to 40VDC

6K32T/ 6K32TR(Reverse)- Fan cooled (3 fans inside)

Email mktg@GarrettCom.com for additional details.

input sources are interrupted), see Appendices B and C.

Std. Terminal Block“ -, GND, + ”

be fixed using software commands.

Relay Alarm Contact (Optional)

Per-port MDI or MDIX on RJ-45

Fuse Required – 2Amps

Fuse Required – 3Amps

Cooling Method-

(6K32TRC)

Agency Approvals

Page 10 of the GarrettCom 6K32T user manual — MODEL DESCRIPTION
Page 10 · click to enlarge
Page 10

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

Magnum 6K32T 16 10/100 RJ-45 ports managed switch with two optional port modules

Each Magnum 6K32T & 6K32TRC base unit has two configurable port modules

6KP8-45-2MT “6+2” module, w/six RJ-45 ports and two 2km mm MTRJ connectors

(6K32T) which may be configured with a selection of 10/100/1000Mb fiber and copper

6KP4-FXSC “2+2” 100Mb Fiber module, w/ four 100Mb 2km FX SC connectors

6KP8-45MLC “4+4” module, w/four RJ-45 ports and four 2km mm LC connectors

6KP8-45SLC “4+4” module, w/four RJ-45 ports and four 15km Sm LC connectors

6KP4-FLSTFX “2+2” ST Fiber module, w/ two 100Mb and two 10Mb ports, 2km 6KP6-RJMST “4+2” module, w/four RJ-45 ports and two 2km mm FX SC’s

6KP8-45MT “4+4” module, w/four RJ-45 ports and four 2km mm FX MT-RJ’s

Magnum 6K32TRC- Reverse convection cooled(no fans) managed switch, with 16

6KP4-F10ST “2+2” 10Mb Fiber module, w/ four 10Mb 2km FL ST connectors

6KP4-FXST “2+2” ST Fiber module, w/ s, four 100Mb 2km FX ST connectors

6KP6-RJSSC “4+2” module, w/four RJ-45 ports and two 20km Sgl.m FX SC’s

6KP6-RJSSCL “4+2” module, w/four RJ-45 ports and two 40km Sgl.m FX SC’s

6KP6-MT10ST “4+2” module, w/four MTRJ ports and two 10Mb 2km FL ST’s 6KP6-RJ10ST “4+2” module, w/four RJ-45 ports and two 10Mb 2km FL ST ‘s

10/100 RJ-45 ports and two optional port modules which may be configured with a selection of 10/100/1000Mb fiber and copper connector types,32 ports max.

6KP8-RJ45 TP Module, w/eight 10/100Mbps auto-negotiating RJ-45 ports

6KP6-RJMSC “4+2” module, w/four RJ-45 ports and two 2km mm FX ST‘s

6KP8-MTRJ SFF Fiber module, w/eight 100Mb mm FX MT-RJ connectors

6KP8-SLC SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors

Magnum 6K32TRC-125VDC:Same as 6K32T except power input is 125VDC

6KP8-MLC SFF Fiber module, w/eight 100Mbps mm FX LC connectors

Magnum 6K32TRC-48VDC:Same as 6K32T except power input is –48VDC

Magnum 6K32TRC-24VDC:Same as 6K32T except power input is 24VDC

Magnum 6K32T-125VDC:Same as 6K32T except power input is 125VDC

Magnum 6K32T-48VDC:Same as 6K32T except power input is –48VDC

Magnum 6K32T-24VDC:Same as 6K32T except power input is 24VDC

Magnum Managed Switch

slot to be configured with any one of the port modules listed below:

Magnum 6K32T & 6K32TRC Port Modules

MODEL DESCRIPTION

1.2 Ordering Information

connector types, max. 32 ports

Configuration Options:

Page 11 of the GarrettCom 6K32T user manual — Magnum Managed Switch
Page 11 · click to enlarge
Page 11

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

6KP5-G4RJ “G+4” module, with one GBIC open transceiver and four 10/100 RJ-45

6KP3-G2SC “G+2” module, with one GBIC transceiver and two 100Mb 2km FX SC

GBPM-2OTX Two port Gigabit module provides two GBIC open transceiver ports for

GBIC-SXSC GBIC transceiver module for use in GBPM-xOTX. One 1000BASE-SX

GBIC-LXSC40 GBIC transceiver module for use in GBPM-xOTX. One 1000BASE-ZX

GBIC-LXSC70 GBIC transceiver module for use in GBPM-xOTX. One 1000BASE-ZX

6KP2-2GSX two-port in one slot Gigabit 6K module, uses one 6K slot and provides two Gb Fiber SXSC (1000BASE-SX Multi-mode) ports. (includes front–panel metal sheet).

6KP2-2GCU two-port in one slot Gigabit 6K module, uses one 6K slot and provides two Gb Copper (1000BASE-RJ45 Auto-negotiating) ports. (includes front–panel metal sheet).

6KP8-45-2SLC “6+2” module, w/six RJ-45 ports and two 100Mb 15km sgl. mode FX LC connectors

GBPM-COTX One slot Gigabit 6K module provides one GBIC open transceiver port

GBIC-LXSC10 GBIC transceiver module for use in GBPM-xOTX. One 1000BASE-

GBIC-LXSC25 GBIC transceiver module for use in GBPM-xOTX. One 1000BASE-

6KP5-1CU4RJ “G+4” module, with one GBIC copper(Auto-negotiating) transceiver

6KP5-1CU4MT “G+4” module, with one GBIC copper(Auto-negotiating) transceiver and four 100Mb MTRJ Fx-Multi-mode connectors (includes front–panel metal sheet)

6KP3-1CU2FXT “G+2” module, with one GBIC copper(Auto-negotiating) transceiver and four 100Mb ST Fx-Multi-mode connectors (includes front–panel metal sheet)

CONSOLE CBL Industry standard serial cable, DB-9 connectors for RS-232 “ null-

CONSOLE USB Console attachment cable, serial to USB, cable with one DB9 for the

MNS-6K License(Management software)- Preloaded with the latest firmware, license

6KM-BLNK Blank cover for one 6K32T & 6K32TRC module slot opening in a

modem “ connection (sometimes called an Xmodem cable), used to connect a PC or a

GBIC-TP GBIC transceiver module for use in GBPM-xOTX. One 802.3ab

and four 10/100 RJ-45 connectors (includes front–panel metal sheet)

managed Switch and a USB interface for the USB connector to a PC.

LX/LH port with 1310nm single mode SC(10km) fiber connector

LX/LH port with 1310nm single mode SC(25km) fiber connector

port with 1550nm, single. mode SC(70km) fiber connector.

port with 1550nm, single mode SC(40km) fiber connector

fiber ports connectors (includes front–panel metal sheet)

connectors (includes front–panel metal sheet)

for a user-selectable GBIC transceiver module

Gigabit Options (Modules using GBIC)

a user-selectable GBIC transceiver module

character terminal to the Management port.

1000BASE-T port with RJ-45 connector

port with multimode SC fiber connector

Magnum 6K32T & 6K32TRC chassis

Modules with Gb, not using GBICs

costs included with each 6K base unit.

Page 12 of the GarrettCom 6K32T user manual — 6K32T/6K32TRC PoE Modules with 48VDC Power Inside
Page 12 · click to enlarge
Page 12

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

6K32T/6K32TRC PoE Modules with 48VDC Pass-Through Configuration options: only one A or B module slot of 6K-Series switch with 48VDC

New P6KP8-RJ45 8 port PoE module for 6ks with 48vdc PS, w/eight PoE power source

New P6KP8-45MLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP8-45-2MT “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP8-452SLC “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJSSCL “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New 6K125VDC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a

New P6KP8-45MT “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP8-45SLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX MTRJ connectors

New P6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New 6KAC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a full-

10/100 auto-negotiating auto cross RJ-45 ports. New P6KP8-45RJ “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

Configuration optionsonly one A or B module slot of 6K32-Series switch with

6K32T/6K32TRC PoE Modules with 48VDC Power Inside

48VDC power input may be configured with a PoE Modules

source and four 10/100 auto-negotiating auto cross RJ-45 ports

full-width rack-mount 6K switch with 125VDC power input.

power input may be configured with a PoE Modules

source and four 100 Mb 2km mm FX MTRJ connectors

source and four 100 Mb 2km mm FX LC connectors

source and four 100 Mb 15km sm FX LC connectors

source and four 100 Mb 15km Sm FX LC connectors

source and two 100 Mb 2km mm FX ST connectors

source and two 100 Mb 2km mm FX SC connectors

source and two 100 Mb 20km sm FX SC connectors

source and two 100 Mb 40km sm FX SC connectors

width rack-mount 6K switch with AC power input.

source and two 10 Mb 2km sm FL ST connectors

Page 13 of the GarrettCom 6K32T user manual — 6K32T/6K32TRC PoE Modules with 48VDC Power Inside
Page 13 · click to enlarge
Page 13

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

New PI6KP6-RJSSCL “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four POE power

New PI6KP8-45MLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-45SLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-45-2MT “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-452SLC “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-45RJ “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-45MT “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX MTRJ connectors

GarrettCom, Inc. reserves the right to change specifications, performance

source and four 10/100 auto-negotiating auto cross RJ-45 ports

characteristics and/or model offerings without notice.

source and four 100 Mb 2km mm FX MTRJ connectors

source and four 100 Mb 2km mm FX LC connectors

source and four 100 Mb 15km sm FX LC connectors

source and four 100 Mb 15km Sm FX LC connectors

source and two 100 Mb 2km mm FX ST connectors

source and two 100 Mb 2km mm FX SC connectors

source and two 100 Mb 20km sm FX SC connectors

source and two 100 Mb 40km sm FX SC connectors

source and two 10 Mb 2km sm FL ST connectors

Page 14 of the GarrettCom 6K32T user manual — 2.0 Introduction
Page 14 · click to enlarge
Page 14

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

In the event there are items missing or damaged, contact the party from whom

product; notify the carrier of any damage that you believe occurred during shipment or

delivery. Inspect the contents of this package for any signs of damage and ensure that

Remove the items from the shipping container. Be sure to keep the shipping

shipping container if possible. Refer to Section 6, Troubleshooting, for specific return

Examine the shipping container for obvious damage prior to installing this

1 Magnum 6K32T, 6K32TR or 6K32TRC Managed Switch, base unit

container should you need to re-ship the unit at a later date. To validate the product

(configured with user-selected port module option in modular slot)

you purchased the product. If the unit needs to be returned, please use the original

warranty, please complete and return the enclosed Product Registration Card to

1 AC Power Cord (U.S. and other 115 VAC only)

1 Set of metal “Ears” for 19” rack mounting

1 Installation and User Guide (this manual)

2.1 Inspecting the Package and Product

1 Product Registration Card

This package should contain:

GarrettCom, Inc. as soon as possible.

the items listed below are included.

2.0 Introduction

procedures.

Page 15 of the GarrettCom 6K32T user manual — 2.2 Product Description - Magnum 6K32TRC Managed Switch
Page 15 · click to enlarge
Page 15

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

stations and temp-uncontrolled outdoor applications. Specially designed and enclosed

Ethernet solutions with 16 10/100 RJ-45 ports fixed and two modular configuration slots.

multiple secured managed features is able to handle industry-standard IEEE 802.1p QOS

friendly, Magnum 6K32TRC Managed Switch is specially designed with a convection

cooled thermal design techniques to minimize heat generation to provide an efficient,

6K32TRC supports modularity in the last two slots to configure with any of the various

modular slots are boosted with 10Mb/10/100Mb/ 100Mb/1000Mb and can be configure

The preloaded robust and intuitive MNS-6K Managed Network firmware with

switching services for both “smooth” streaming and “bursty” data traffic. For redundant

Figure 2.2.1aA typical 6K32TRC front view, 16 RJ-45 ports (Fixed) +2 Modular

prioritization and non-blocking wire speed on all ports. It provides high performance

highly reliable and secured Ethernet solution for heavy duty Industry, Power sub-

in a “Reverse” aluminum case, the 6K32TRC proudly offered with modularity, port

Being a sibling of the successful 6K managed switch family, the Magnum

Gigabit(1000Mb) options to handle high bandwidth application efficiently. The two

with any of modules offered with copper or Fiber media or combo. The various PoE

modules option is an additional advantage for Magnum 6K32TRC users to provide a

6KP modules offered. The Magnum 6K32TRC provides effective and economical

2.2 Product Description - Magnum 6K32TRC Managed Switch

The IEC61850 complied and attributed with “green” environmentally

The two modular configurable slots of the Magnum 6K32T offer the flexibility to

configure up to sixteen 100Mb, (RJ-45 and 16 fiber ports) or a maximum of four

density (up to 32 ports max.) and security in a 1U rack-mount package.

slot with 8 Port fiber on C and Dual Giga module on D slot.

secure and economical solution to critical remote applications.

Page 16 of the GarrettCom 6K32T user manual — (CLI)
Page 16 · click to enlarge
Page 16

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

port modules (6KPM). These modules come with copper and fiber-built-in (emphasizing

combinations, and 1Gb or (1+1) Dual Gb port module selections using GBIC transceivers

environments, or 24VDC for Industrial and 125VDC for power sub stations applications.

play hardware operation, 802.1p packet prioritization in hardware, and industry-standard

include SNMPv3, SSL/SSH, 802.1X, TACACS+, Port Security, and Tagged VLANs

and a secured user friendly web based option. The IGMP feature for multicast traffic

http://www.garrettcom.com/techsupport/software/userguides/mns6k_webmanual.p

The Magnum 6K32TRC‘s port flexibility can be achieved via a family of 6K

Small Form Factor fiber for high fiber port density), 6-port modules for fiber and RJ-45

10Mb and 100Mb fiber, copper, and 1000Mb Gigabit ports can be easily handled by the

and Industrial applications, the Magnum 6K32TRC provides high performance plug-and-

LANs, it offers S-ring, RS-Ring, Link-Loss-Learn, STP and RSTP. Security features

and streaming video application and IGMP-L2 mode feature is an attempt to provide a

in copper or fiber. These modules can be factory configured in a base chassis unit (or

application and Ethernet media requirements. Evolving mixed-media requirements for

The packaging and wide selection of AC and DC power-input options with (-

applications. The chassis rack mounting style as “Reverse” (with the ports and LEDs

duplicate set of LEDs in the front). Rack widths accommodated include standard 19”

Designed for primarily use in power sub- stations, un-controlled temperature

may be changed in the field by trained technicians) to adapt the unit as per the user’s

http://www.garrettcom.com/techsupport/software/userguides/mns6k_CLI.pdf

See MNS-6K materials for further details about Management software.

48VDC, 24VDC, 125/110 VDC, target the Magnum 6K32TRC for heavy-duty

and the power-input and the management console connector all in the rear and a

RETMA, ETSI, and 23” Telco. Input power may be AC, or –48VDC for Telco

Layer 3 solution with 6K-Switches effectively and economically.

Magnum 6K32TRC product reliably

(CLI)

df (web)

Page 17 of the GarrettCom 6K32T user manual — 2.2.1a Magnum 6K32T Managed Switch Chassis
Page 17 · click to enlarge
Page 17

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

2 modular slots available to configure with numerous 6KPM options. The options can be

of ease of use through “Secure Web based management and scripts feature to manage the

6K32T switch remotely”. The 6K32T loaded with robust MNS-6K firmware is specially designed to meet the future demand of Ethernet requirement with cost-effective secure

The high port density and fan cooled Magnum 6K32T was designed for heavy

The 6K32T Switches have 16port fixed RJ-45(10/100Mb) ports and

through port security, Radius X, Tacacs+ and Snmpv3 and provide an effective solution

LEDs are on the front and the available ports along with the power supply area found on

managed networks software functionality with plenty of secure and remote monitoring

duty Carrier class and Industrial applications that require high port density and secure

This rack mountable managed switch comes with a wide variety of AC/DC options to

data-video” over Ethernet will be handled efficiently by this managed switch and will

solutions. The Magnum 6K32T is also available in a Reverse model option, where the

devices which save in cost, rack space and running cool to provide reliable solutions.

Figure 2.2.1b6K32T front view, configured for16 RJ-45 ports +2 Modular slot

demand for complex Ethernet. The Triple Play demand of bandwidth to meet “voice-

features of this managed switch. The switch allows the users to secure their network

The modules which may be configured and used in the modular slots of the

RJ-45 or fiber media, 10 or 100 or 1000Mb copper or Fiber, or Small Form Factor

options to provide more fiber ports. The two modular slots can be configure with

The modular option with two slots explores this managed switch’s extra

capability to meet any 10 or 100 or Gigabit requirement effectively satisfying any

The growing demand of security and “Ease of use” are the other adding

deliver an effective and efficient solutions for the required application needs.

the rear side. This configuration is mostly used for carrier-class market.

2.2.1a Magnum 6K32T Managed Switch Chassis

maximum of four Gigabit modules as shown in Fig. 2.2.1.b..

play an effective role in providing modularity to the solution.

features, all in convenient 1U rack-mount packages.

Magnum 6K32T are described here.

with Dual Giga module.

Page 18 of the GarrettCom 6K32T user manual — ACT
Page 18 · click to enlarge
Page 18

ACT

F/H

ACT

F/H

ACT

F/H

ACT

F/H

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The Magnum 6K32T is preloaded with robust and intuitive MNS-6K Managed

combinations, and 1Gb or 2Gb port module selections using GBIC transceivers in copper

changed in the field by trained technicians) to adapt the unit to the user’s application and

Ethernet media requirements. Evolving mixed-media requirements for 10Mb and 100Mb

Network Software to handle industry-standard IEEE 802.1p QOS prioritization and non-

both “smooth” streaming and “bursty” data traffic. For redundant LANs, it offers S-ring,

Small Form Factor fiber for high fiber port density), 6-port modules for fiber and RJ-45

input and the management console connector all in the rear and a duplicate set of LEDs

in the front). Rack widths accommodated include standard 19” RETMA, ETSI, and 23”

2.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb fiber

blocking wire speed on all ports. It provides high performance switching services for

modules (6KPM). These modules come with copper and fiber-built-in (emphasizing

or fiber. These modules can be factory configured in a base chassis unit (or may be

6K32TRC for heavy-duty applications. The chassis mounting rack style may be “regular” (with the ports and LEDs in the front and the power input and management

console connector in the rear) or “Reverse” (with the ports and LEDs and the power-

Telco. Input power may be AC, or –48VDC for Telco environments, or 24VDC for

The Magnum 6K32T’s port flexibility is achieved via a family of 6K port

SSL/SSH, 802.1X, TACACS+, Port Security, and Tagged VLANs. See MNS-6K

2 4 6 8 LK LK LK L

2 4 6 8 LK LK LK L

RS-Ring, Link-Loss-Learn, STP and RSTP. Security features include SNMPv3,

fiber, copper, and Gigabit ports can be easily handled by the Magnum 6K32T &

The packaging and power-input options target the Magnum 6K32T &

1 3 5 7

Fig.2.2.2SFF Fiber Port Modules, 6K8-MTRJ (to the left) and

AC

F/H

F/H

AC

AC

F/H

AC

F/H

materials for further details about software.

ACT

F/H

ACT

F/H

ACT

F/H

ACT

6K8-MLC or -SLC (below)

F/H

F/H LK LK LK LK

1 3 5 7

2 4 6 8 LK

Industrial applications.

ACT

F/H

ACT

ACT

F/H

ACT

F/H

6K32TRC product reliably

Page 19 of the GarrettCom 6K32T user manual — 2.2.3 Eight-Port Copper Module, 6K8-RJ45 (MDIX)
Page 19 · click to enlarge
Page 19

10/100 LK

2 4 6 8 F/ H ACT

10/100 LK

F/H ACT

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

for operation at 10 or 100Mb speed in full- or half-duplex mode, i.e., each independently

selects a mode and speed to match the device at the other end of the twisted pair cable.

(See Section 4.3 for auto-negotiation and MDIX details). The auto-crossover feature will

and performance. Using the 6K32T & 6K32TRC’s MNS software, the user may select

There are three LED’s per fiber port. The Link (LK) LED indicates “ready for

Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK)

speed (100Mb), mode, and connector type. Models that are available with Small Form

Factor (SFF) are multi-mode MT-RJ or LC-type connectors, and single-mode LC-type

normally are set (factory default) to operate in full-duplex mode for best fiber distance

full- or half-duplex mode per-port through the set-up of the software (See the Magnum

6K32T & 6K32TRC MNS Software Manual for the flexibility to adapt to any FDX or

operation” on that port when lit, the F/H LED indicates operation in full-duplex mode

indicator for that port must be ON (indicating there is a powered-up device at the other

default setting) are independently N-way auto-negotiating, and auto-crossover(MDIX)

In an eight-port SFF fiber port module, all of the fiber ports are of the same

The 100Mb fiber eight-port modules for the Magnum 6K32T & 6K32TRC

when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving

1 3 5 7

end of the cable) in order for a LK LED to provide valid indications of operating

automatically determine the other side of connection to make the connection, and

eliminate the need of cross-over cable.

HDX type of Fast Ethernet devices).

provides eight 10/100Mb switched

2.2.3 Eight-Port Copper Module, 6K8-RJ45 (MDIX)

The 6K-Series’s 8-port Copper

port module, model 6K8-RJ45,

switched ports normally (as a

RJ-45 ports. The 10/100Mb

conditions on that port.

connectors.

Page 20 of the GarrettCom 6K32T user manual — LK/ACT 2
Page 20 · click to enlarge
Page 20
GarrettCom 6K32T — 4 FULL/HALF diagram (page 20)
Fig. 3

2 1 3 5 7 10/10 0 LK/ACT 1

2 1 3 5 7 10/10 0 LK/ACT 1

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that port

On the model 6K8-RJ45 module, there are four LEDs for each port, two in the

connector and two separate. The LK (Link) LED indicates “ready for operation” on that

an RJ-45 port and the Link (LK) indicator for that port must be ON (indicating there is a

powered-up device at the other end of the cable) in order for a LK LED to provide valid

Using the 6K8-Series (MNS-6K) management software, the user may disable

auto-negotiation and fix the desired operation of each RJ-45 port. User may select 10Mb

inside PoE option is factory configured and equipped with the necesasary power option

to support four 802.3af PoE pd devices. The 4-RJ45 POE module are also available with

mix –n-match with fiber modules. Please check the ordering information Sec.1.2. for all

when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10 Mb

GarrettCom 6K32T — 4 FULL/HALF diagram (page 20)
Fig. 4

2.2.3a New PoE(Power Inside), model PI6KP8-45RJ (MDIX), 8-port 10/100Mb

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

or 100Mb speed and full- or half-duplex mode per-port as per user requirement. (See

45 (10/100) ports maxm. support POE(Power Inside) option in one rack mounted 6K-unit. The power

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to

8 Port@ 10/100Mb POE Copper ports

8 Port@ 10/100Mb POE Copper ports

4 FULL/HALF

4 FULL/HALF

E

E

PI6KP8V-45RJ

PI6KP8V-45RJ

Magnum MNS-6K Software Manual for details info.).

LK/ACT 2

LK/ACT 2

indications of operating conditions on that port.

the various PI6K PoE modules option.

The FDX/HDX LED is ON to

cable must be connected into

speed when OFF (when auto-

negotiation is not disabled).

duplex mode. A twisted pair

and OFF to indicate half-

standard. Only 4 x RJ-

power on each port to

The New PoE RJ-45

ports act similar to

IEEE802.3af PoE

power up the PD

Show 9 more labels / short text on this page
10/100 · 10/100 · PoE · PoE · indicate full-duplex operation · capability of providing · regular RJ-45 ports, · except they have · devices, per the
Page 21 of the GarrettCom 6K32T user manual — ACT
Page 21 · click to enlarge
Page 21

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

except they have capability of providing power on each port to power up the PD devices,

connected properly to a 803.af compliant PD device on that port. When non-PoE devices

PoE LED is ON when connected properly to a 803.af compliant PD device on that port.

When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

2.2.3b New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8- port

The PoE (Power-pass-through) RJ-45 ports act similar to regular RJ-45 ports,

are connected, the PoE LED is OFF. Operation of Ethernet data traffic is not affected by

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

2.2.4 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45 and 2@100Mb

four 10/100 switched RJ-45 copper ports and two 100Mb switched multi-mode fiber ST,

48vdc power input. The PoE modules are also available with mix –n-match with fiber modules. Please check the ordering information Sec.1.2 for all the various P6K PoE

The combo six-port modules are combinations of copper and fiber media, available as

per the IEEE802.3af PoE standard. The Power Pass-through PoE modules are totally

F/H ACT

dependent upon the powerful -48VDC input power supply to support more RJ-45

(10/100) ports. Each port requires atleast 15watts to power up the PoE PD devices.

Maxm. one PoE modules can be configured in the A, B or C slot of any 6K s with -

10/100 LK

2 6 TX RX TX LK RX LK

1 3 5 7

ACT

fiber

F/H

that is marked as LINK/ACT, as shown in the diagram.

that is marked as LINK/ACT, as shown in the diagram.

ACT

F/H

10/100 LK

F/H ACT

2 6 TX RX TX LK RX LK

4@RJ-45 + 2@ 100Mb ST or SC

1 3 5 7

traffic is not affected by PoE.

ACT

F/H

When the PoE port

is in use, the PoE

LED is ON when

modules option.

shown in Fig 2.

ACT

F/H

PoE.

Show 6 more labels / short text on this page
to regular (non-PoE) · The LEDs · on 6KP8-RJ45- PoE · module are slightly · different compared · RJ-45 modules as
Page 22 of the GarrettCom 6K32T user manual — ACT
Page 22 · click to enlarge
Page 22

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The four RJ-45 ports operate just like the 8-port copper module with auto-cross

On Magnum “4+2” Combo modules, there are four LED’s for each RJ-45 port,

which indicate status the same as described for the 6K8-RJ45 in Section 2.2.3 above. The

fiber modules except for the 10Mb speed. For port numbering, ports 1, 2, 5, 6 are present,

hub or media converter or almost any other device with a 10Mb fiber Ethernet port. User

(MDIX) feature to eliminate the use of cross-over cable, and the two fiber ports operate

at 100Mbps full-duplex (default). User mode control per port through the MNS software

fiber port’s LEDs indicate status the same way as described for the SFF fiber modules in

duplex, which allows the Magnum 6K32T & 6K32TRC Switch to connect to any 10Mb

SC or single mode SC or Long Reach SC ports. For ports numbering, ports 1,3,5,7 are

The 4port @10Mb ST fiber modules behave the same as the 8@100Mb ST

Section 2.2.2 above. Color-coding on the panel of the module shows which LEDs

The Magnum Combo six-port modules are also available with 4@ MTRJ

100Mb mm SFF fiber and 2@10Mb fiber mm ST ports, and with 4@ RJ45 10/100

GarrettCom 6K32T — 2.2.5 Four-Port 10 Mb mm Fiber ST Modules diagram (page 22)
Fig. 5 · 2.2.5 Four-Port 10 Mb mm Fiber ST Modules

ports 3, 4. 7, 8 are not present. The default setup on the 10Mb fiber module is half-

mode control per port through the MNS software is the same as the other 6K32T &

above. For detailed information about 10Mb mm ST fiber half of the module, see

copper, ports 2 and 6 are fiber, ports 4 and 8 are not present.

2.2.5 Four-Port 10 Mb mm Fiber ST Modules

TX RX LK

R

LK

2 6 T

ACT

F/H

ACT

F/H

operation of the SFF fiber

copper and 2@10Mb fiber mm ST

and the RJ-45 half of the module is

as described for those port types

TX RX LK

TX RX LK

belong to which port.

4@ RJ-45 + 2@ 10 Mb ST

ACT

F/H

ACT

F/H

is also the same.

Section 2.2.5.

ports. The

Page 23 of the GarrettCom 6K32T user manual — ACT
Page 23 · click to enlarge
Page 23

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

speed with multiple choices for the modular slot. The new Magnum 6K32T & 6K32TRC

can be configured with four Gigabit ports (copper or Fiber) maximum. The Gigabit port

single Gigabit module comes in flavors of G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber

F/ ACT

standard GBICs to provide Gigabit (Gb) media flexibility. GBIC models are available for

duplex mode at any time. The Gigabit fiber port has LEDs that indicate LK (Link status)

1@ 1000Mb Fiber SC + 2@ 100Mb SC 1@ 1000Mb Fiber SC + 4@10/ 100Mb

The 1000Mb Gigabit fiber-port modules on the Magnum 6K32T & 6K32TRC

performance. The 1000Mbps SC fiber-optic module on the Gigabit -SX and Gigabit-LX

There are two LEDs mounted on each Gigabit port module. The Gigabit fiber

10BASE-FL standard, i.e., 2km distance for multi-mode fiber. (Single-mode for up to

The Magnum 6K32T & 6K32TRC & 6K32’s offer wide options for Gigabit

Gigabit port modules have been offered as GBPM-2OTX (fiber or RJ-45), whereas the

10/100 L

are normally set (factory default) to operate at AUTO mode for best fiber distance and

port is by default configured to AUTO mode, and can be fixed at 1000Mbps speed full-

The 6K32T & 6K32TRC modules provide a GBIC opening for insertion of industry-

6K32TRC modules. The fiber ports support fiber cabling distances according to the

1 3 5 7

both multi-mode (550m) and single-mode (10, 25, 40, 70)km fiber options, and for

For Dual Gigabit modules option, please check page#60 for details info.

option for the modular slot comes in a couple of different configurations. The two

transceivers are compatible with the IEEE 802.3z Gigabit standards.

10Km distance may be available as a special order configuration).

TX RX AC

Gigabit copper as well with new models appearing often.

ACT

F/

and ACT (receiving activity) on that port when lit.

2.2.6 Gigabit (1000Mbps) port modules

TX LK RX

ports) as shown below in the figure.

ACT

F/

TX RX L

TX RX LK

ACT

ACT

F/

F/

Page 24 of the GarrettCom 6K32T user manual — 2.2.8 Frame Buffering and Flow Control
Page 24 · click to enlarge
Page 24

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

support for QOS, the MNS software (R3) supports two priority queues that can be shared

across the eight levels of defined packet priorities for application-specific priority control

users from datagram paths that go all across a network. As a LAN device, the Magnum

6K32T & 6K32TRC can do its part to prevent any QOS degradation while it is handling

802.1p standard and fulfills its role in support of QOS, giving packet processing priority

the correct CRC, i.e., are good packets. This eliminates the propagation of bad packets,

"express") impose minimal frame latency, they will also permit bad frames to propagate

fragment frames (which are a result of late collisions) to be forwarded which add to the

network traffic. Since there is no way to filter frames with a bad CRC (the entire frame

forward operation is that more bandwidth is available for good packets when the traffic

packets out to the devices sending packets to cause “flow control”. This tells the sending

Magnum 6K32T & 6K32TRC’s are store-and-forward switches. Each frame

occur. This technique ensures that all forwarded frames are of a valid length and have

out to the Ethernet segments connected. The "cut-through" technique permits collision

collisions and bad packets are more likely when traffic is heavy, the result of store-and-

Quality of Service means providing consistent predictable data delivery to

The Magnum 6K32T & 6K32TRC switching hardware supports the IEEE

to priority tagged packets according to the 802.1p standard. In addition to hardware

(or packet) is loaded into the Switch’s memory and inspected before forwarding can

When the Magnum 6K32T & 6K32TRC Switch detects that its free buffer

must be present in order for CRC to be calculated), the result of indiscriminate cut-

through forwarding is greater traffic congestion, especially at peak activity. Since

devices to temporarily stop sending traffic, which allows a traffic catch-up to occur

without dropping packets. Then, normal packet buffering and processing resumes.

While other switching technologies (such as "cut-through" or

queue space is low, the Switch sends industry standard (full-duplex only) PAUSE

enabling all of the available bandwidth to be used for valid information.

2.2.7 Packet Prioritization, 802.1p QOS

by the user through software configuration settings.

2.2.8 Frame Buffering and Flow Control

Ethernet traffic through its ports and buffers.

load is greatest.

Page 25 of the GarrettCom 6K32T user manual — 6K32TRC
Page 25 · click to enlarge
Page 25

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

3.2), which allows the configuration of the Magnum 6Ks as a Managed Switch and other

All MNS-6K software information, including new releases and upgrades related to MNS-

www.GarrettCom.com/techsupport/index.htm#software and look for Magnum

Software enabled features. For additional information about MNS-6K, see the Magnum

Another feature implemented in Magnum 6K32T & 6K32TRC Switches is a

collision-based flow-control mechanism (when operating half-duplex only). When the

Switch detects that its free buffer queue space is low, the Switch prevents more frames

Alternatively, for documentation and latest information on GarrettCom proprietary

For upgrading the Magnum 6K32T & 6K32TRC Switch to its latest

2.2.9 Managed Network Software (MNS-6K) for Magnum 6K32T &

Magnum 6K32T & 6K32TRC come with licensed MNS-6K Firmware (Rel

Magnum MNS-6K Operator Training – This interactive training software

gives the basic and advanced information about the Magnum MNS-6K management

from entering by forcing a collision signal on all receiving half-duplex ports to stop

6K-Series MNS Software User guide in pdf format, a separate document normally

http://www.garrettcom.com/techsupport/software/upgrade_mns6k.pdf

Magnum 6K-Firmware, follow the steps and instruction provided on -

6K software, can be accessed and download from GarrettCom’s FTP site.

For further information, please email: support@GarrettCom.com.

accessed via your web-browser, at ftp://ftp.garrettcom.com/

or FTP client program by ftp.GarrettCom.com using

software and is a useful tool for a first time user.

passwordm6kuser
userm6kuser

MIBs for SNMP visit

incoming traffic.

MNS-6K info..

6K32TRC

Page 26 of the GarrettCom 6K32T user manual — 2.3 Features and Benefits
Page 26 · click to enlarge
Page 26

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

Magnum 6K32T & 6K32TRC & 6K32TRC Switches provide non-blocking (all ports

can run at full speed at once) performance with standard Managed Networks Software

10/100Mb ports or one or two Gigabit ports for backbone connections where managed network services are desired.

processing priority to priority tagged packets according to the IEEE 802.1p standard.

Small Form Factor (SFF) and GBIC fiber connectors. RJ-45 10/100 ports can also be

The port modules are normally factory installed and tested, but may be changed in the

The standard rack mounting provides Ethernet ports and status LEDs in front, service

Standard AC power input has an IEC plug and is auto-ranging for worldwide use. For

special applications, models with –48VDC or 24VDC or 125VDC are available. Dual

Fiber ports take more power than copper ports, but the Magnum 6K32T & 6K32TRC

The Magnum 6K32T & 6K32TRC switching hardware supports QoS, giving packet

For port- and application-specific priorities, the QoS software may be configured by

Magnum 6K32T & 6K32TRC Managed Switches are designed with modular slots to

types and speeds. There are over 20 different modules in the family to choose from.

Source DC input can also be selected and configured on the DC power input models.

design provides for this with heavy-duty components. The ambient temperature can

single-mode; 10 Mb, 100Mb and 1000Mb speed; full-and half-duplex; and classic

„ Modular design for port flexibility, in a 1U space-saving rack-mount package

The 1U Magnum 6K32T & 6K32TRC chassis has 1 slot for port configurations. A

family of 2, 4, 6 or 8 port modules allows the user to select the desired mix of port

Standard 19’ rack mount brackets are included, with ETSI and 23” Telco optional.

„ Heavy-duty design for Telco (NEBS tested) and other industrial environments

naturally include fiber ports and support mixes of the following; multi-mode and

„ Rack-mounting may be standard or “reverse”, 19 inch or ETSI or 23” Telco

connections (power input and management console) in the rear. “Reverse” rack

mounting provides status LEDs in front and all cabling connections in the rear.

„ Standard AC power input, -48VDC or 24VDC or 125VDC input is optional

(MNS-6K) included. They are typically used in LAN traffic centers with 24

„ Switching services includes 802.1p QoS packet prioritization

„ Managed switching for high performance Ethernet LANs

configured in the mix of port types.

2.3 Features and Benefits

be up to 55°C.

the user.

field.

„ Features Fiber-Built-In

Page 27 of the GarrettCom 6K32T user manual — 2.4 Applications
Page 27 · click to enlarge
Page 27

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

Spanning Tree Protocol, RSTP, LLL, S-Ring Redundancy Mgr, (optional) multi-level

an administratively-configured broadcast domain. The network administrator determines

Release 3.5 (summer ’06) includes SNMP, Secure Web Management, RMON, CLI,

departmental networks, and LAN traffic centers that require Gigabit backbone services.

center. The subnet connections may be via fiber or twisted pair cabling, 100Mbps or 10

The mixed-media capability in the modular slot is ideal for upgrading existing

Ethernet LAN networks where existing cabling must be accommodated. The fiber-built-

performance in an Ethernet network center. A secure VLAN-enabled network is simply

QoS, Port and Tag-based VLANs, GVRP, IGMP Snooping, SNMPc GUI support;

Magnum 6K32T & 6K32TRC Fiber Switches offer high performance along

6K32TRC Switches are used in a variety of Power sub-stations applications including,

inter-connect a series of subnets (one subnet per 6K32T Switch port) in a LAN traffic

which ports and nodes are in which broadcast domains by setting membership profiles

„ MNS-6K licensed Network Management Software included, S-Ring/RS-Ring

Port Security; Port Mirroring; Port Settings Control; Telnet, TFTP, FTP support,

„ MDI-MDIX Auto-negotiating on RJ-45 ports for convenient cascading using

„ Support PoE module to provide power via RJ-45 cable on the modular slot.

The performance characteristic of the 6K32T & 6K32TRC Switches enables them to

Equipped with lots of advanced management features, the Magnum 6K32T

with one or two modular slot options to fulfill the choice of copper/Fiber, 10,100 or

1000Mb requirements. The 6K32T & 6K32TRC also offers MNS-6K management

software loaded with multiple useful features. The Magnum IEC61850 6K32T &

in media capability provides future-proof fiber cabling for the LAN structure. The

secured management features offer a multiple options to provide a secure Network

Managed switch is able to handle a VLAN application and provide security and

Industrials and temp. un-controlled, secure VLAN- performance upgrades to

BootP and DHCP client for IP configuring, Radius X, TACACS+ etc.

Example 1Magnum 6K32T Switch for a VLAN application

Mbps speed, and full-or half-duplex mode.

straight RJ-45 cable.

2.4 Applications

solution.

optional

Page 28 of the GarrettCom 6K32T user manual — Data
Page 28 · click to enlarge
Page 28

Data

GarrettCom 6K32T — Data diagram (page 28)
Fig. 6 · Data

Data

Magnum 800E Workgroup Hub 100 GARRETT LINK RX LINK RX PWR COL 1 2 4 5 6 8

100Mbps Full duplex Fiber for

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The modularity of the 6K32T Managed Switch makes it an attractive choice for

Magnum 6K32T Switch. A main NT-server in a secure area protected from earthquake or

another Bldg.

R&D, and Marketing need to each keep a secure LAN, the 6K32T’s VLAN feature will

information controlled. The Managed Magnum 6K32T equipped with VLAN capability

use in applications with LAN connections to an organization’s multiple site offices. The

Full-duplex future proof fiber media can easily connect long distance subnets

Example 2. In another Telecommunications storage data application, a secure managed

multiple subnets. The backbone consists of high speed LAN segments supported by

ports are required for multiple subnets inside the building. The entire spread network is

Magnum 800E Workgroup Hub 100 GARRETT LINK RX LINK RX PWR COL 1 2 4 5 6 8

different offices can be easily connected together with the Fiber ports supported by the

subnets to easily manage the network. Secure web-based management is also included,

mining server for the vital database located in a separate secured building. The copper

managed to provide easy, detectable, uninterrupted support through a viewable SNMP

for each of them. The Magnum 6K32T’s VLAN capability can be configured in two

In an office environment where departments such as Finance, Engineering,

is ideal for any application where a secure VLAN to multiple departments is needed.

switch is required to provide an Ethernet backbone for a diversified network with

1000Mbps full-duplex future-proof fiber media to provide secure long distance LAN connections. The entire network is sharing a higher bandwidth Gigabit-enabled data-

capability of the Magnum 6K32T Switch helps create a database of all the network

prevent traffic cross-over among traffic domains and thus keep sensitive data and

and provide a stable secure network to all applications. The SNMP management

with authentication and encryption to keep out even determined trouble-makers.

fire hazards can be connected to one or two full duplex Gigabit Fiber ports.

10Mb Workgroup 100Mb Servers

1 2 3 4 5 6 7 8 9 10 11

types of virtual LANs; Port-based VLANs and Tag-based VLANs.

12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11

Magnum DS8016 Stackable Hub

10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

UPLINK

12 13 14 15 16

Magnum DS8016 Stackable Hub

10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

LK/RX PORT

COL 10

COL 100

UPLINK

PWRBR

LK/RX PORT

Magnum 800E Workgroup Hub 100 GARRETT LINK RX LINK RX PWR COL 1 2 4 5 6 8

PWRBR

COL 10

COL 100

Magnum 800E Workgroup Hub 100 GARRETT LINK RX LINK RX PWR COL 1 2 4 5 6 8

Magnum 800E Workgroup Hub 100 GARRETT LINK RX LINK RX PWR COL 1 2 4 5 6 8

1 2 3 4 5 6 7 8 9 10 11

12 13 14 15 16

Magnum DS8016 Stackable Hub

10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

UPLINK

1 2 3 4 5 6 7 8 9 10 11

LK/RX PORT

PWRBR

COL 10

COL 100

1 2 3 4 5 6 7 8 9 10 11

12 13 14 15 16

Magnum DS8016 Stackable Hub

10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

UPLINK

Magnum 800E Workgroup Hub 100 GARRETT LINK RX LINK RX PWR COL 1 2 4 5 6 8

10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

100Mb Servers

COL 10

LK/RX PORT

PWRBR

COL 100

Data

monitor.

Data

Show 12 more labels / short text on this page
Data · and Workstations · 100Mb Servers · Data · Data · Data · Data · and Workstations · Data · and Workstations · 100Mb Servers · and Workstations
Page 29 of the GarrettCom 6K32T user manual — Example 3 Redundant Application (6K32TRC)
Page 29 · click to enlarge
Page 29

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The 6K32T Managed Switch with NEBS Level 3 compliance and management

choices of modules to support future expansion as the network evolves. The dual Gigabit

no-single-point-of-failure self-healing LAN topology along with a ring of multiple 6K25s

The Magnum 6K32T Managed Switch equipped with copper and optional dual Gigabit

network requirements by providing copper/fiber media along with the higher bandwidth

VLAN, Port security, 802.1X, and other security features to provide a secure and stable

advantage by fulfilling the present requirements as well as benefiting from the multiple

industry standard Rapid Spanning Tree Protocol 802.1d is used in the top eight switches

(see diagram below) to perform GB mesh fault recovery, whereas the bottom ring setup

has been configured with S-Ring and Link-Loss-Learn for faster recovery in a big ring.

support of 10/100 and 1000Mb. The user can utilize the SNMP feature equipped with

port option in the modular slot boosts the bandwidth for high speed to support the peak

The Magnum 6K32T with two Gigabit ports in the modular slot allows it to

connect into a Gigabit mesh structure with an RSTP and S-Ring combination used in a

A redundant LAN setup not only provides a reliable recovery solution from

money and recover valuable time. In a critical application where secure data has been

The figure below has Magnum 6K32T’s and 6K25’s connected over the gigabit mesh

requirements. The user-configurable Magnum 6K32T provides an extra boost to the

Loss-Learn and various security features are easily qualified for the application. The -

48VDC input power option with Dual Source is especially useful in telecom central offices.

at the edge to allow the system to efficiently recover from a fault in the network. The

stored in a data mining storage facility, a redundant network provides a more secure

flexibility allows the user more than one configuration alternative. The user has an

mountable managed switch with over 24 ports is required with dense port features,

Magnum 6K32T’s equipped with redundant LAN features like S-Ring, RSTP, Link-

network faults, but also improves operating up-time to simplify maintenance, save

fiber ports on modular slots provide an economical and seamless solution to the

In a redundant application for high network availability where a rack-

structure for a high bandwidth secure redundant LAN setup.

Example 3 Redundant Application (6K32TRC)

traffic and minimize congestion.

network as per the requirement

solution.

Page 30 of the GarrettCom 6K32T user manual — Example 3 Redundant Application (6K32TRC)
Page 30 · click to enlarge
Page 30

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The Magnum 6K32TRC with two slots filled with Gigaport

bandwidth. The SNMP option and secure web based will allow the remote capability and

Example 4In a “ (video+data)” application where a network being designed to catered

handle the bandwidth requirement and 16 10/100 RJ-45 ports to feed the other needs of

GarrettCom 6K32T — Example 3 Redundant Application (6K32TRC) diagram (page 30)
Fig. 7 · Example 3 Redundant Application (6K32TRC)

the need of multicast streaming and broadcast traffic of higher bandwidth to provide a

efficiently. The New IGMP L2-Mode feature on Magnum 6K32TRC and loaded with

equipment connected to the 6K32TRC. The robust Tag based vlan feature will able to

monitoring the network securely. The versatile mechanical design with rack mounting

capability and AC/DC option will be an additional feature to take care of temperature

module and a robust management firmware with MNS-6K qualify this requirement

The Dual Giga option on each of the two slot add 4 Gigaport to

segregates different ports belong to one group and provide an effective solution for

management capability and secure web feature fulill this requirement effectively.

6K32TRC in a Redundant application

video conferencing and video in demand channel option to the user.

and power option issue.

Page 31 of the GarrettCom 6K32T user manual — F/H
Page 31 · click to enlarge
Page 31

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2

GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 31)
Fig. 8 · Figure 4: A multicast traffic through a 6K32TRC Swit…

6K32TRC to meet the fastest growing application of video monitoring or video surveillance demand of industry and provide an economical and effective solution to

Equipped with IGMP-L2 mode enhanced features allow the Magnum

LK/ACT

LK/ACT

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

16 14 12 10 8 6 4 2

6K32TRC with IGMP-L2 mode

F/H

F/H

F/H

F/H

F/H

F/H

F/H

F/H

F/H

F/H

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

mode feature with Gigabit redundancy

F/H

16 14 12 10 8 6 4 2 F/H

LK/ ACT

LK/ ACT

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

LK /ACT

LK /ACT

16 14 12 10 8 6 4 2

F/H

F/H

meet that expectation.

F/H

16 14 12 10 8 6 4 2 F/H

F/H

F/H

F/H

F/H

F/H

F/H

LK/ACT

LK/ACT

16 14 12 10 8 6 4 2

F/H

F/H

F/H

F/H

Show 26 more labels / short text on this page
10/ 100 · 10/ 100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/ 100 · 10/ 100 · 10/ 100 · 10/ 100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/ 100 · 10/100 · 10/100
Page 32 of the GarrettCom 6K32T user manual — 3.0 Installation
Page 32 · click to enlarge
Page 32

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment

must be less than or equal to 55C FOR 6K32T and 60C for 6K32TRC.

2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate airflow must be maintained for proper and

3.) If the equipment is mounted in an enclosed or multiple rack system, placement of the equipment must not load unevenly or

4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent

of network devices need to be connected in order to communicate with each other. These

compact size allows it to be easily placed in an office or lab area, and it can also be either

GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 32)
Fig. 9 · Figure 4: A multicast traffic through a 6K32TRC Swit…

5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and

This section describes installation of the Magnum 6K32T Switches, as well as

The location of a Magnum 6K32T Switch is dependent on the physical layout

of the network. Typically the Switch is placed in a central wiring location where groups

because they have rubber feet they can also be installed on a shelf or table top unit. The

Before installing the equipment, it is necessary to take the

6.) 24vdc, -48vdc, and 125vdc must be installed in restricted access locations.

7.) CB-Circuit breaker of 10Amps should shown on top of Rack.

Switches are typically rack mounted in a wiring closet see Section 3.3.2 below), but

overloading of the building/s electrical circuits.

Locate an AC receptacle that is within six feet

rugged metal case of the Magnum 6K32T will normally

monitor the status LEDs. Keep an open area around the

left side while the unit is in operation. See figure below.

protect it from accidental damage in a lab or workplace

setting. Maintain an open view of the front to visually

unit so that cooling can occur from the small fan on the

(2 meters) of the intended Magnum 6K32T site. The

3.1 Locating Magnum 6K32T Switches

shelf of wall-mounted (see Section 3.3.1 below).

Figure 3.1Location of the Magnum

connection of the various Ethernet media types.

uncompromised earthing path.

overload the rack system.

following precautions:

3.0 Installation

safe operation.

6K32T’s cooling fans

Page 33 of the GarrettCom 6K32T user manual — 3.2 Connecting Ethernet Media
Page 33 · click to enlarge
Page 33

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

1 mm = multi-mode 2 sgl.m = single-mode 3.2.1 Connecting Fiber Optic ST-type, “twist-lock”

2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue

unit. This is accomplished by using a family of different port Modules which

connectors. This procedure applies to ports using a 6K32T & 6K32TRC module,

1. Before connecting the fiber optic cable, remove the protective dust caps from the

dampened in alcohol. Make certain the connectors are clean before connecting.

5. The LINK LED on the front of the PM will illuminate when a proper connection

has been established at both ends (and when power is ON in the unit). If LINK is

not lit after the cable is connected, the normal cause is improper cable polarity.

designed to support all standard Ethernet media types within a single Switch

The following procedure applies to installations using a PM with ST-type fiber

3. Connect the Transmit (TX) port (light colored post) on the Magnum PM to the

Receive (RX) port of the remote device. Begin with the color-coded strand of

can be individually selected and configured per-port. See Section 2.4 for a

The various media types supported along with the corresponding IEEE

4. Connect the Receive (RX) port (dark colored post on the PM) to the Transmit

(TX) port of the remote device. Use the non-color coded fiber strand for this.

small form factor mm1 Fiber 2.0km (6,562 ft) 6K8-MTRJ, -MLC small form factor sgl.m1 Fiber 15 km 6KP8- SLC

bands at regular intervals; you must use the color-coded strand on the

Swap the fiber cables at the PM connector to try to remedy this situation.

The Magnum 6K32T & 6K32TRC Switches are specifically

IEEE Standard Media Type Max. Distance Port Module

100BASE-FX mm1 Fiber 2.0km (6,562 ft) 6K6-MSC, -MST

sgl.m2 Fiber 18.0km (95K ft) SSC, SSCL

10BASE-T, 100BASE-TX twisted pair 100m (328 ft) 6K8-RJ45

1000BASE-TX twisted pair 100m (328 ft) GBIC-TP

802.3 and 802.3u standards and connector types are as follows:

1000BASE-FX mm1 Fiber 220m ( ft) GBIC-SXSC

sgl.m2 Fiber 70km GBIC-LXSC

associated ports at each end of the fiber optic segment.

the cable for this first TX-to-RX connection.

3.2 Connecting Ethernet Media

description of the PMs.

MST-type port.

Copper:

Fiber:

Page 34 of the GarrettCom 6K32T user manual — 3.2.3 Connecting Single-Mode Fiber Optic
Page 34 · click to enlarge
Page 34

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The following procedure applies to installations using a PM with SC-type fiber

(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx

fiber allows full bandwidth at longer distances, and may be used to connect 10 Mb nodes

following two media types100BASE-TX and 10BASE-T. CAT 5 cables should be used

mixed-speed network, since dual-speed ports are auto-sensing for either 10 and

1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is
2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is

connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable

The RJ-45 ports of the Magnum 6K32T & 6K32TRC can be connected to the

when making 100BASE-TX connections. When the ports are used as 10BASE-T ports,

The following procedure describes how to connect a 10BASE-T or 100BASE-

are the diameters of the core and the core plus the cladding respectively). Single-mode

3.2.4 Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or Shielded)

CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair

Twisted Pair (CAT 3, 4, 5) 10BASE-T RJ-45

TX twisted pair segment to the RJ-45 port. The procedure is the same for both

When using single-mode fiber cable, be sure to use single-mode fiber port

Twisted Pair (CAT 5) 100BASE-TX RJ-45

and 100Mb) be used whenever possible in order to provide flexibility in a

When connecting fiber media to SC connectors, simply snap the two square male

connectors into the SC female jacks of the 6KPM until they click and are secure.

The same procedure for multi-mode fiber applies to single-mode fiber

Media IEEE Standard Connector

shielded, either unshielded or shielded cables and wiring may be used.

3.2.2 Connecting Fiber Optic SC-type, "Snap-In"

connectors, i.e., using 6K-MSC or 6K-SSC (single mode) etc.

connectors. Follow the steps listed in Section 3.2.2 above.

3.2.3 Connecting Single-Mode Fiber Optic

unshielded and shielded twisted pair cables.

up to 10 Km apart, or 18Km with the 6K-SSC.

cabling is 100 meters (328 ft).

100Mb/s.

established

Page 35 of the GarrettCom 6K32T user manual — 3.2.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceivers
Page 35 · click to enlarge
Page 35

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

could produce kigh (greater than 2500V ) levels of ground potential rise (GPR)

during line-to-ground fault conditions. The 6K32 passes the 1613specifications

either case, the maximum distance for unshielded twisted pair cabling is 100 meters (328

Mb and 1000Mb) be used whenever possible in order to provide flexibility in a

1. 1000BASE-T connections require that all four pairs or wires be connected. Insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port.

communications for both telecommunication and data communications applications. Due

for zero packet loss with fiber ports & with RJ45 ports used as indicated here.

The RJ-45 1000BASE-TX Gigabit ports of the Magnum 6K32T & 6K32TRC

1000BASE-T, CAT-5e, or for better results, 100-ohm UTP shielded twisted pair (STP) balanced cable. The CAT-5e or the more effective 100-ohm UTP shielded twisted pair

The following procedure describes how to connect a 1000BASE-T twisted pair segment

2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established

3.2.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceivers

telecommunication multiplexers installed in close proximity (i.e., less than 2

to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted

The small form-factor pluggable (SFP) is a compact optical transceiver used in optical

substation applications to interface to field devices across distances which

(STP) balanced cable is recommended when making 1000BASE-TX connections. In

advises that, for substation applications, the RJ-45 ports are intended for

3.2.5 Connecting Twisted Pair (CAT-5e or better, Unshielded or Shielded)

meters or 6.5ft) to the 6K32. It is not recommended to use these ports in

can be connected via copper media with the following minimum specifications;

Media IEEE Standard Connector

connectivity to other communication equipment such as routers or

Twisted Pair (CAT-5e) 1000BASE-T RJ-45

cables and wiring may be used.

mixed-speed network.

pair cables.

ft).

Page 36 of the GarrettCom 6K32T user manual — TX RX
Page 36 · click to enlarge
Page 36

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

for various applications. The small-chassis Magnum 6K is designed for industry-standard

transceiver for any reason. Not removing the fiber cable first can damage the fiber cable,

to its compact, hot pluggable characteristics, SFPs are becoming a very popular choice

higher cabling. The maximum length supported on copper 1000BASE-T is 100mts (328

All SFPs used in Magnum 6Ks are compliant with the industry standard Multi-Source

other device, it is recommended to use Crossover RJ-45 (4-twisted pair) category 5 or

Gb-SFPs and Gb-SFPCU (copper) for user selection of the SFP gigabit media type as

recommended to use a straight-through RJ-45(4-twisted pair) connection while

connecting to any Server/workstation. While connecting with any Switch/repeater or

GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 36)
Fig. 10 · Figure 4: A multicast traffic through a 6K32TRC Swit…

cable connector or optical interfaces. It is advised not to remove and insert a SFP

Agreement (MSA) ensuring compatibility with a wide range of networking kit.

TX RX

TX RX

Side View ---Duplex LC connector -- Front view

transceiver frequently as this may shorten its useful life.

SFP modules are static sensitive devices.

GarrettCom 6K32T — TX RX diagram (page 36)
Fig. 11

desired.

ft.).

Bail clasp · Bail clasp

Page 37 of the GarrettCom 6K32T user manual — 6KP2-2GSFP 2 SFP
Page 37 · click to enlarge
Page 37

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

3.2.7 Power Budget Calculations for Magnum 6K32T & 6K32TRC PM’s with

Receiver Sensitivity and Transmitter Power are the parameters necessary to

compute the power budget. To calculate the power budget of different fiber media

where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

installations using Magnum products, the following equations should be used:

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

The various SFPs transceivers supported by GarrettCom 6KQs D slot are-

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

SFP-SX Gb SX, 850nm wavelength, 500 m distance

SFP-LX10 Gb LX, 1310nm wavelength, 10km dist

SFP-LX25 Gb LX, 1310nm wavelength, 25km

SFP-ZX40 Gb ZX, 1550nm wavelength, 40km

SFP-ZX70 Gb ZX, 1550nm wavelength, 70km

Gb Modules, fixed ports--SFP (Small Form Factor)

OPB (Optical Power Budget) = PT(min) - PR(min)

Gb SFP fiber optic transceivers

6KP2-2GSFP 2 SFP

1 CU

6KP2-1GSFP1CU 1SFP

6KP1-1SFP 1SFP

6KP1-1GCU 1 CU

Show 5 more labels / short text on this page
Module Model# Gigabit · distance · distance · distance · Fiber Media
Page 38 of the GarrettCom 6K32T user manual — ZXSC40
Page 38 · click to enlarge
Page 38
GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 38)
Fig. 12 · Figure 4: A multicast traffic through a 6K32TRC Swit…

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LXSC25)

and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km(LXSC40)

and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (LXSC70)

Lucent’) web sites and catalogs to provide guidance to network designers and installers.

mode 18+ (0.4) 1300 9/125 -15 -31 14 28 17.5 35

mode 40 (0.4) 1300 9/125 -5 -34 29 58 32.5 65

mode 2 (0.4) 1300 62.5/125 -19 -31 12 4 16 5.7

1000Mb Multi- mode 0.55 850 62.5/125 50/125 -9.5 -17 5.5 2 12.5 4

1000Mb Single- mode 10 1300 9/125 -9.5 -20 8.5 17 10.5 21

1000Mb Single- mode 25 1550 9/125 -4.0 -21 15 37.5 17.5 43

1000Mb Single- mode 40 1550 9/125 -4.0 -21 15 60 17.5 70

1000Mb Single- mode 70 1550 9/125 -3.0 -23 18 90 20.5 102

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only

The following data has been collected from component manufacturer’s (Agilent’s and

Mode 15+ (0.4) 1310 9/125 -15 -28 11 22 - -

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

if the following factors are both applied:

ZXSC40

ZXSC70

GBIC-

GBIC-

Page 39 of the GarrettCom 6K32T user manual — 10/100 LK 2 4 6 F/ AC
Page 39 · click to enlarge
Page 39

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

  • The worst-case OPB of the fiber link must be greater than the fiber cable’s

The Magnum 6K32T & 6K32TRC Managed Switches can be easily mounted

on a table-top or any suitable horizontal surface. They have four rubber feet to provide

3.3.1 Rack-mounting (for 19” RETMA racks), Magnum 6K32T & 6K32TRC’s Installation of a Magnum 6K32T & 6K32TRC Fiber Switch in a 19” rack is a

GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 39)
Fig. 13 · Figure 4: A multicast traffic through a 6K32TRC Swit…

Switch (regular package, not the

Reverse version), which is then

The 23” brackets and the ETSI

(European metric, approx. 21”) brackets are also available (optional) for rack-mounting

  • The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the

full-duplex (factory default) setting for 100Mbps fiber ports must be used,

typically fastened into a standard

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

simple procedure. The units are 1U (1.70”) high. When properly installed, the front-

19” RETMA rack as shown here

mounted LED status indicators should be in plain view and easy to read.

stability without scratching finished surfaces.

3.3 Table-Top or Shelf Mounting

10/100 LK 2 4 6 F/ AC

1 3 5 10/100 LK

F/H AC

passive Attenuation.

6K32TRC unit). These brackets attach to the front sides of the

10/100 LK 2 4 6 F/ AC

1 3 5 10/100 LK

F/H AC

10/100 LK 2 4 6 F/ AC

Magnum 1 3 5 10/100 LK

F/H AC

Fiber Switch

GARRET

Show 5 more labels / short text on this page
and · Magnum PW · Magnum · Managed · Switch
Page 40 of the GarrettCom 6K32T user manual — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2
Page 40 · click to enlarge
Page 40

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The optional 23” brackets and the ETSI (21”) brackets each come as a pair in a

industry where they are a standard for Central Office rack-mounting purposes. The 23”

The bracket mounting holes in the sides of the Magnum 6K32T & 6K32TRC

permits it to be mounted in various ways. The same holes fit all three types (19”, ETSI,

and 23”) of brackets. The mounting for the 23” is illustrated in Figure 3.3.1 below. The

Model has all of the cabling (Ethernet cabling, power cabling and console port cabling)

incident with the ports are still present there, and a second or dual set of LEDs are used

These brackets are rack-mounted in a frame typically accessed in operation from both

package, along with the necessary screws for attaching the brackets to the sides of the

the Magnum 6K32T & 6K32TRC Switches. These brackets are popular in the Telco

brackets may be attached flush with the front, or attached in the center for a set-back

3.3.2 Rack-mounting, Reverse version of the Magnum 6K32T’s (Not available as of October 2005) The optional Reverse Magnum 6K32T

connectors in the rear, and the status LEDs in the front. The status LEDs that are co-

Fig 3.3.2 Reverse Magnum 6K32TRC units, rack-mounted in a frame

Magnum Switch unit. They must be ordered as separate line items.

for status visibility in the front of the unit, showing the same data.

and the ETSI brackets are mainly used for larger equipment

GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 40)
Fig. 14 · Figure 4: A multicast traffic through a 6K32TRC Swit…

mounting which may reduce cabling torque.

sides.

Show 5 more labels / short text on this page
Mid-Range Mount · Standard Flush · Mount Bracket · Rear Mount · or
Page 41 of the GarrettCom 6K32T user manual — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2
Page 41 · click to enlarge
Page 41

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

frame, 23” frame, or ETSI (21”) frame. The 19” brackets are included with each unit, the

With each bracket type, there are three different mounting options as shown in Fig. 3.3.2.

AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz.

connected or disconnected without concern for AC power-related problems or damage to

Power supply options are available to suit the 6K32T & 6K32TRC Switches to

3.4.1 Alarm Contacts for monitoring internal power, and Software Traps The Alarm Contacts feature, optional on Magnum 6K32T & 6K32TRC’s,

6K32T & 6K32TRC case. The AC or DC power input connection is in the same panel. A manual On-Off Switch for power to the unit is not available on 6K32T & 6K32TRC units

with the Alarm Contacts option, as these two features occupy the same space in the case.

enabled, the Form C Normally Closed (NC) contact is held close during normal software

The case of the Magnum 6K32T has mounting holes prepared for each of the mounting

The Magnum 6K32T & 6K32TRC Switches incorporate an internal universal

power supply and have a recessed male IEC connector for the AC power cord at the left-

rear. A manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard

power cord is supplied with each unit shipped within the United States and Canada.

The 32-port units will consume over 30 watts of power typically. When connecting the

sets of status monitoring wires at the green terminal block. When this option is present,

The first NC Alarm Contact (top position) is a “Software Alarm”, operated

feature with a software configuration command if desired. When the Software Alarm is

The auto-ranging power supply supports installation environments where the

Ethernet cabling, there is no need to power down the unit. Individual segments can be

See the Appendices of this manual for more details. Use an RFQ for other variations.

provides two Form C Normally Closed (NC) contacts to which the user can attach two

the terminal block for Alarm Contacts is part of the Power Input panel in the Magnum

operation. A user-defined software malfunction, such as an SNMP Trap or a Software

special high-availability communications and/or heavy industrial-grade applications,

There are three options of brackets available to mount in the standard 19”

arrangements. Users may choose the mounting arrangement most suitable for their

3.4 Powering the Magnum 6K32T & 6K32TRC Managed Switch

by user settings in the MNS-6K software. The user can disable the Software Alarm

* -48VDC, 24VDC and 125VDC with dual-source DC input,

* -48VDC, 24VDC and 125VDC with single DC input,

other two may be purchased as separate options.

installation.

including:

the unit.

Page 42 of the GarrettCom 6K32T user manual — STOP!!!
Page 42 · click to enlarge
Page 42

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The second (bottom position) NC Alarm Contact is held close when there is

1. There is four terminal block (1,2,3,4)provided next to AC/DC power supply 2. The top two pins (1,2) are software operated 3. The bottom two pins (3,4) are hardware operated 4. By default it is NC (normally closed) 5. The software operation needs to be enabled and set to get the Alarm traps. For detailed information about the Software Alarm and software control of SNMP alarm traps, please

power on the main board inside of the 6K32T & 6K32TRC. This provides a “Hardware

Alarm” because the NC contacts will open when internal power is lost, either from an

3.5 6K32T & 6K32TRC Port Module (6KPM) Installation The Magnum 6K32T & 6K32TRC Switches are normally received from the

electronic equipment) are sensitive to static discharge. Use proper ESD

1. Make sure the 6KPM Card package has all necessary accessories to install it

(Daughterboard (Bigger) and Granddaughter board (smaller), three 5/8 stand

situations where 6KPM cards need to be added or replaced. In cases where a 6KPM

offs for the Granddaughter board, six #4-40 Pan-Head screws along with a

Security violation or an S-Ring Fault, causes the contact to open and thus trigger an

factory with 24 ports fixed and one required 6KPM module installed. There may be

external power down condition or by the failure of the power supply inside of the

module needs to be added in the modular slot, the faceplate for an available front-

mounted slot must be removed. The following procedure describes this operation.

performed by trained service persons. The port modules (like most

properly. Each 6KPM Card package for field installation contains

Magnum 6K32T & 6K32TRC Switch. Useful info. about Alarm contacts:

reference the Magnum MNS-6K Software User Manual. (Chapter 19th).

Failure to do so may result in damage to the unit

from the chassis before attempting to remove

for all powers single or dual, is unplugged

Be sure the power cord and connections

3.5.1 Preparation for Installing and Removing 6KPMs

and/or replace any PM cards.

and will void the warranty.

STOP!!!

measures when handling port modules.

alarm in the user’s monitoring system

Page 43 of the GarrettCom 6K32T user manual — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2
Page 43 · click to enlarge
Page 43

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

intended for temporary connectivity to other equipment such as PCs. Since the

Front panel face plate package. The Front panel faceplate package includes 3

mixed with other Fiber combo 6KPM card packages. Always install the PM

The Magnum 6K32T & 6K32TRC chassis are combined with top, bottom and

screws. There are 5 screws located on the front-bottom and 3 at rear-top of the

screws (total 12) as shown in the fig 3.5.1a. Once these are removed, the front

panel can be easily pulled out to the front. The top cover can be easily pulled

Granddaughter board. The copper 6KPM card should not work properly if

console port connection is temporary, it is excluded from IEEE 1613 packet-

off to the front from the chassis base, as shown in the Fig. 3.4.1b. When the

advises that, for substation applications, the serial RJ-45console ports are

unit and one each on the front and rear sides. First Remove the front panel

front panel parts and assembled together with the help of 17 Philips-head

chassis top cover has been removed, the interior of the unit is exposed.

Figure 3.5.1aRemoving front panel after the screws being removed

loss testing per the 1613 standard-defined test procedure.

module separately one by one to avoid the mixing.

GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 43)
Fig. 15 · Figure 4: A multicast traffic through a 6K32TRC Swit…

retainer brackets and six #2-56 flat head screws.

2. Remove Chassis Cover
Page 44 of the GarrettCom 6K32T user manual — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2
Page 44 · click to enlarge
Page 44

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

individual PM installation spaces and female latch (white) connectors provided on the far

right side of main board along with four stand-off’s for 6KPM card position. (See Figure

3. Remove front panel

chassis cover. Looking into the

face plate retaining screws

There are one PM slot located

vertical placed Chassis cover

bracket with retaining screws

Figure 3.5.1cMagnum 6K32T & 6K32TRC modular slot side (front-right side),

on the front-right side of the

(#256 flat head ) which hold

of the unit, there are one

Looking down into the Magnum 6K32T & 6K32TRC unit, notice that there are

GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 44)
Fig. 16 · Figure 4: A multicast traffic through a 6K32TRC Swit…
Fig 3.5.1bPulling out the top coved from the chassis base
GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 44)
Fig. 17 · Figure 4: A multicast traffic through a 6K32TRC Swit…

3.5.1c).

without chassis cover

Page 45 of the GarrettCom 6K32T user manual — 3.5.2 Installing 6KPM Cards in the Magnum 6K32T & 6K32TRC
Page 45 · click to enlarge
Page 45

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

2. Placed Granddaughter board (as shown in fig. 3.5.2a and 3.5.2b) on the chassis

Granddaughter board The 5/16 stand off has been used to place the daughter board on the

Fig 3.5.2b Granddaughter Board placed in modular slot and secured with three 7/16

used to secure a PM face plate in position, but unscrew only four of the screws as shown

plate which can be subjected to significant forces from the attached cables. (See Figure

built in stand off (female) provided at the front of the 6K32T & 6K32TRC Main Board

the PM Face plate card slot securely. These six screws shown in the picture below are

in Fig. below. These screws are also used to secure the individual 6KPM cards screen

3.5.2 Installing 6KPM Cards in the Magnum 6K32T & 6K32TRC

6K32T & 6K32TRC Managed Switch unit. Follow these steps to install a 6KPM.

Figure 3.5.1dTop View – 6KPM retaining screws hold Face Plate

Up to four front-mounted 6KPM cards may be installed in one Magnum

GarrettCom 6K32T — 3.5.2 Installing 6KPM Cards in the Magnum 6K32T & 6K32TRC diagram (page 45)
Fig. 18 · 3.5.2 Installing 6KPM Cards in the Magnum 6K32T & 6K…
GarrettCom 6K32T — 3.5.2 Installing 6KPM Cards in the Magnum 6K32T & 6K32TRC diagram (page 45)
Fig. 19 · 3.5.2 Installing 6KPM Cards in the Magnum 6K32T & 6K…
1. Remove top chassis cover. See procedure in Section 3.5.1 above.

and screw down tightly with the three 5/16 stand-off (male) on the top of the

top of the granddaughter board and latch it securely.

stand-off’s as shown with arrow mark

3.5.1d)

Page 46 of the GarrettCom 6K32T user manual — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2
Page 46 · click to enlarge
Page 46

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

(male) placed at the

aligned with stand offs then press slowly and firmly with two fingers (as shown

card fits into the space provided on the main board over the grand-daughter Bd. and the

4. Hold the daughter

Fig 3.5.2e Daughter Bd. Being placed over the Grand daughter Bd. and the mating

5. Once the latching connectors are aligned properly and the mounting holes are

below in Fig. 3.5.2f) on the top of the latching connectors until the connectors

3. The figure here illustrates the basic layout of an individual PM card. 6KPM

hands at the end

and align the two

Fig 3.5.2dDaughter Board shown upside down with two male latch connectors

the other female connector placed on the Granddaughter and main board. As shown

male latched cream color connector( as shown in above fig. with arrow mark).

GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 46)
Fig. 20 · Figure 4: A multicast traffic through a 6K32TRC Swit…
GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 46)
Fig. 21 · Figure 4: A multicast traffic through a 6K32TRC Swit…

connector being matched to lockup properly

above in Fig. 3.5.2e

Show 6 more labels / short text on this page
latching connectors · board with both · bottom of the · cream color · daughter board with · latched
Page 47 of the GarrettCom 6K32T user manual — 6K32TRC & 6K32
Page 47 · click to enlarge
Page 47

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

6K32TRC & 6K32

6KPM slots empty, always

use a face plate (Magnum

the end, so that it holds the daughter board securely. The figure below shows the

the front panel screen plates(come along with the 6K-module) need to be properly placed

cooling air flow, safety, and operation as required by FCC, CE, and other regulations.

6. Now screw down the daughter board with 7 #440 screws except the last two at

top view of 6KPM card after successfully installing the 6KPM cards inside the

7. Once the installation of granddaughter and daughter modules is done properly,
Fig.3.5.2fSecurely

Fig. 3.5.2g Top View :

6K8-BLNK) to cover the slot opening in the front panel. This will maintain proper

inside a 6K32T &

6K32TRC.

on the front of the chassis cover to complete the installation process.

GarrettCom 6K32T — 6K32TRC & 6K32 diagram (page 47)
Fig. 22
GarrettCom 6K32T — 6K32TRC & 6K32 diagram (page 47)
Fig. 23
Show 6 more labels / short text on this page
Magnum 6K32T & · latching up 6KPM · 6KPM Module installed · Cards into a · Magnum 6K32T & · 6K32TRC Switch
Page 48 of the GarrettCom 6K32T user manual — 3.5.3 Removing 6KPM Cards
Page 48 · click to enlarge
Page 48
GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 48)
Fig. 24 · Figure 4: A multicast traffic through a 6K32TRC Swit…

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

gently pull out the

reaches the rear end and fit properly to match the holes. Make sure the chassis

cover is aligned properly before securing the enclosure. Place the front panel

8. Once the 6KPM cards have been installed, the chassis top cover should be

part at the end by sliding in to the front side and secure it with 12 screws as

To properly remove a 6KPM card from the 6K32T & 6K32TRC Managed

replaced by matching at the two front corners properly and slide in until it

2. Remove retaining screws placed on top for the 6KPM and Face Plate
1. Remove chassis cover See procedures in Section 3.5.1 above.
GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 48)
Fig. 25 · Figure 4: A multicast traffic through a 6K32TRC Swit…

the chassis. The screen faceplate screws out from

the inside front of the chassis cover by loosening

firmly. Figure 3.5.3aTop View

On the top of the daughter module there are six

standoffs holding the Granddaughter board with

the 4 screws and bracket while holding it down

position (see Figure 3.5.3a). Remove the three

retaining screws for each 6KPM card. These

Switch, follow the 3 steps below.

screws are used to secure a 6KPM card in

- 6 retaining screws shown by arrows

3.5.3 Removing 6KPM Cards

being mentioned earlier.

3. Remove 6KPM Card
Show 7 more labels / short text on this page
connectors, using · gripping the board · from the latching · near the latch-up · daughter board · Carefully and · both hands,
Page 49 of the GarrettCom 6K32T user manual — CONSOLE
Page 49 · click to enlarge
Page 49

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

and keep off from dust and other unavoidable substance, otherwise can cause a failure

3.6 Connecting the Console Terminal to Magnum 6K32T & 6K32TRC

connectors as shown in Fig. 3.5.3b . If the now empty slot is to remain unused, be sure

2. If the PM module in the modular slot is not being installed properly or loose in connection, the MNS-6K management software will not boot-up properly and a error

will generate as –{ failed to read register device type (offset 0x1600) on slot “A or B or

Use a DB-9 “null modem” cable to connect the Magnum 6K32T & 6K32TRC

Console Port (the RS-232 port on the 6K32T & 6K32TRC Switch) to the your

slot must be covered with Blank cover, to maintain proper air-inflow inside the unit

PC, so that your PC becomes the 6K32T & 6K32TRC’s Console Terminal.

6K32T & 6K32TRC Switch configuration for Network Management, please refer to Magnum 6K32T & 6K32TRC Software Manual available on GarrettCom‘s FTP site.

3. Always boot-up the Switch after any new module installation on modular slot to confirm the successful installation, before placing the chassis cover.

Detail info. about the MNS is available on 2.2.9 ( see page no. 13) of this manual.

O

OF

to install a 6KPM-BLNK face plate cover.

Follow the step 8 to complete the process successfully.

Figure 3.5.3bRemoving a 6KPM Card

C or D”}, whichever the slot has been used.

Rear View of Magnum 6K32T

unit package.

Console (DB-9) Por t

(Management)

in the Switch.

CONSOLE

PORT

Page 50 of the GarrettCom 6K32T user manual — Pin Signal Description
Page 50 · click to enlarge
Page 50

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The above provided information enables a managed station( a PC or Console terminal) to

intended for temporary connectivity to other equipment such as PCs. Since the

female to female cable is required to communicate properly. The Null-Modem (DB-9)

console port connection is temporary, it is excluded from IEEE 1613 packet-

3.6.1 RS-232 (DB-9) Console Com port (Serial port) pin assignments.

advises that, for substation applications, the serial RJ-45console ports are

1 CD Carrier detect (not used)

3 TXD Transmit Data (output)

cable is optional and can be order from the factory, along with the unit as-

Pin Signal Description

2 RXD Receive Data (input)

loss testing per the 1613 standard-defined test procedure.

5 GND Signal Ground

4 open not used

6-9 open not used

connect directly to the switch using a straight through cable.

DB-9 (Console port connector)

Pin 5 Pin 1

CONSOLE CBL for serial port

CONSOLE USB for USB port

Page 51 of the GarrettCom 6K32T user manual — 4.0 OPERATION
Page 51 · click to enlarge
Page 51

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

wire-speed among all of its ports. The Magnum 6K32T & 6K32TRC support 10/100Mbs

maintenance. The only hardware configuration settings are user options for an UP-LINK

through MNS-6K software per unit as per the requirement. The internal functions of both

Each time a packet arrives on one of the switched ports, the decision is taken to

either filter or to forward the packet. Packets whose source and destination addresses are

on the same port segment will be filtered, constraining them to that one port and relieving

node addresses suitable for use in larger networks. They are self-learning, so as nodes are

This chapter describes the functions and operation of the Magnum 6K32T &

for copper media and 10 or 100Mb separate traffic domains for fiber ports to maximize

bandwidth utilization and network performance. All ports can communicate to all other

ports in a Magnum 6K32T & 6K32TRC, but local traffic on a port will not consume any

the rest of the network from having to process them. A packet whose destination address

is on another port segment will be forwarded to the appropriate port, and will not be sent

to the other ports where it is not needed. Traffic needed for maintaining the operation of

The Magnum 6K32T & 6K32TRC Switches operate in the store-and-forward

added, removed or moved from one segment to another, the 6K32T & 6K32TRC Switch

A Magnum 6K32T & 6K32TRC provides switched connectivity at Ethernet

Magnum 6K32T & 6K32TRC units are plug-and-play devices. There is no

Switch (resides inside the unit) on the 6K8-RJ45 (modular port). Optional Half / Full

duplex mode and 10 or 100Mbps selection for the switched ports must be configured

the network (such as occasional multi-cast packets) are being forwarded to all ports.

All Magnum 6K32T & 6K32TRC units have address table capacities of 4K

software configuring necessary to be done for basic operation at installation or for

switching mode, which eliminates bad packets and enables peak performance to be

achieved when there is heavy traffic on the network.

automatically keeps up with node locations.

4.1 Switching Functionality

of the bandwidth on any other port.

6K32TRC Switch.

4.0 OPERATION

are described below.

Filtering and Forwarding · Address Learning

Page 52 of the GarrettCom 6K32T user manual — 4.2 Status LEDs
Page 52 · click to enlarge
Page 52

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

PWR : Power LED, ON when external power is applied to the unit.

ACT : ON with port activity for 10 Mbps and 100Mbps operation.

4.3 Auto-Cross (MDIX)Auto-negotiation, for 10/100Mbps RJ-45 ports

such cases, the 10/100 speed or the F/H mode may be affected, but auto-cross in the

The Managed Magnum 6K32T & 6K32TRC Fast Ethernet copper ports can be

Software user guide (MNS-6K). One frequently-used application for the Managed

remote 100Mb device. In this case, it is desirable to operate the fiber link at 100Mb

An address-aging algorithm causes least-used addresses to fall out in favor of

copper ports to other unmanaged switches, legacy hubs, managed switches, media-

where the switch manager fixes the port settings via software, and the result of the

standard. The selection is made via 6K-MNS software. The factory default setting

LK : Steady ON, Link status for 10 Mbps and 100Mbps operation.

100/10 : Speed LED, ON when the speed is 100Mbps , OFF when the speed is 10 Mbps

The 24 RJ-45 ports on Magnum 6K32T & 6K32TRC support auto-cross (MDI or

MDIX) in the auto-negotiation mode according to the IEEE 802.3u standard. No

auto-negotiation is changed in the managed switch by the manager commands. In

speed, and at either half- or full duplex mode depending on the capabilities of the

crossover cables are needed when connecting the 6K32T & 6K32TRC’s 10/100

converters etc. Please note that there can be conditions with managed switches

set for either fixed 100Mb speed or N-way auto-negotiation per the IEEE802.3u

is for auto-negotiation. At 100Mb-fixed speed, the user may select half- or full-

6K32T & 6K32TRC Switch copper ports is to connect one of them using a fiber

frequently-used addresses. To reset the address buffer, cycle power down-and-up.

duplex mode by 6K-MNS Software for each RJ-45 port separately. For detail

media converter to another Switch in the network backbone, or to some other

F/HFull / Half duplex LED, ON when the port is running full

6K32T & 6K32TRC Switches will still work. The auto-cross function can be

information see Section 7 (Port Setup) of Magnum 6K32T & 6K32TRC

disabled, if fixed the port at 10 or 100Mb through software..

For all Magnum 6K32T & 6K32TRC models :

duplex, OFF for half duplex.

4.2 Status LEDs

Page 53 of the GarrettCom 6K32T user manual — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2
Page 53 · click to enlarge
Page 53

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

mostly do not support auto-negotiation properly, and require that the switched port

to which they are connected be at 100Mb fixed speed. Attachment to 10/100 auto-

through MNS software port settings and can check the port status of each port after

speed and F/H modes possible depending on what the other device supports. These are:

The auto-negotiation logic will attempt to operate in descending order and will normally

mode” result can change at any time depending on network changes that may occur). If

remote device. Standard commercially available Fast Ethernet media converters

negotiation and are connected to another auto-negotiating device, there are 4 different

-- the devices at both ends of the cable are capable of operation at either 10

  • NOTE – Some NIC cards only auto-negotiate when the computer system

arrive at the highest order mode that both devices can support at that time. (Since auto-

the device at the other end is not an auto-negotiating device, the 6K32T & 6K32TRC’s

Switch’s RJ-45 ports handle this situation by configuring the ports as per desire

(1) 100Mb full-duplex, (2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb

Auto-negotiation per-port for 802.3u-compliant switches occurs when:

that they are in is powered up. These are exceptions to the “negotiate at

negotiation is potentially an externally controlled process, the original “highest order

When Magnum 6K32T & 6K32TRC RJ-45 copper ports are set for auto-

negotiation ports typically will not work properly. The 6K32T & 6K32TRC

-- the second of the two connected devices is powered up*, i.e., when

LINK – enabled” rule above, but may be occasionally encountered.

-- the LINK is re-established on a port after being lost temporarily.

Mb or 100Mb speed and/or in full- or half-duplex mode, and can

send/receive auto-negotiation pulses, and . . .

LINK is established for a port, or

the change.

half-duplex.

General information -

Page 54 of the GarrettCom 6K32T user manual — 4.4 Flow-control, IEEE 802.3x standard
Page 54 · click to enlarge
Page 54

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

RJ-45 ports will try to detect its idle signal to determine 10 or 100 speed, and will default

may be limited within that collision domain. The Path Delay Value (PDV) bit-times must

Magnum 6K32T & 6K32TRC Switches incorporate a flow-control mechanism

This is most likely to occur when data is moving from a 100Mb port to a 10 Mb port and

attempting to transmit to one 100Mb port, and in other protracted heavy traffic situations.

used. When the available free-buffer queue increases, the Switch will send a “RESUME"

frames from entering the device by forcing a collision indication on the half-duplex ports

for Full-Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a

lost packets. The transmitting device is commanded to stop transmitting into the 6K32T

that are receiving. This temporary “collision” delay allows the available buffer space to

When operating in 100Mb half-duplex mode, cable distances and hop-counts

transmitted to the sender when the packet buffer is nearly filled and there is danger of

account for all devices and cable lengths within that domain. For Magnum 6K32T &

6K32TRC Fast Ethernet switched ports operating at 100Mb half-duplex, the bit time

long burst of activity causes the switch to save frames until its buffer memory is full.

the 10Mb port is unable to keep up. It can also occur when multiple 100Mb ports are

Magnum 6K32T & 6K32TRC Switches implement the 802.3x flow control

& 6K32TRC Switch port for sufficient time to let the Switch reduce the buffer space

packet to tell the transmitter to start sending the packets. Of course, the transmitting

pressure algorithm on 10/100 Mb ports for flow control. That is, the switch prevents

device must also support the 802.3x flow control standard in order to communicate

5.0 Magnum 6K32T & 6K32TRC Managed Switch Port Modules

(non-blocking) on Full-Duplex ports, which provides for a “PAUSE” packet to be

This chapter describes each Port Module (PM), including appearance,

improve as the switch catches up with the traffic flow.

4.4 Flow-control, IEEE 802.3x standard

to half-duplex at that speed per the IEEE standard.

functionality, and status displays.

properly during normal operation.

delay is 50BT.

Page 55 of the GarrettCom 6K32T user manual — 5.1 Inspecting the Package and Product
Page 55 · click to enlarge
Page 55

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

Remove the 6K32T & 6K32TRC PM(s) from the shipping container.

For a list of 6K32T & 6K32TRC Port Module types, refer to Section 1.2

Be sure to keep the shipping container should you need to ship any of the PMs

An important feature of the Magnum 6K32T & 6K32TRC is the use

of one Port Modules for flexible mixed-media connectivity to RJ-45 and fiber

designed to support all standard Ethernet media types at 10 or 100Mps speed.

RJ-45 ports or used for COMBO module is set as (=) as other ports.

contact your supplier. If you need to return the unit, use the original shipping

media in the modular slot. Since the Magnum 6K32T & 6K32TRC Switches

connecting Ethernet segments with its individual connector type and media.

This section applies only to PMs shipped as separate items, i.e., 6K32T &

installing a 6K32T & 6K32TRC PM; notify the carrier of any damage you

believe occurred during shipment or delivery. Inspect the contents of this

package for any signs of damage and ensure that the items listed below are

Each 6K32T & 6K32TRC PM can provide two, four, six or eight ports for

Each 6K PM is individually described in the following sections.

separately at a later date. In the event there are items missing or damaged,

have dual-speed capability for copper ports, the 6 or 8-port interfaces are

6K32TRC PMs not factory installed in a Magnum 6K32T & 6K32TRC

Examine the shipping container for obvious damage prior to

container if possible. Refer to Chapter 5 for specific return procedures.

Installation instructions, with illustrations

6K32T & 6K32TRC PMs

5.1 Inspecting the Package and Product

5.2 6KPM Module Description

This package should contain:

modular slot.

included.

Page 56 of the GarrettCom 6K32T user manual — Module
Page 56 · click to enlarge
Page 56

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

6K32TRC Managed Switch, the copper port supports the standard distance 100m on each

5.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist

Link (LK) LED that indicates proper connectivity with the remote device when lit, and

The 6KP6-RJ10ST is a six port combo module that looks similar to

The ST-connector functions as a fiber optic transceiver to support 10BASE-FX network

copper port supports the standard distance 100m on each port and the fiber port supports

Link (LK) LED that indicates proper connectivity with the remote device when lit, and

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The

5.2.1a 6KP6-RJ10ST, 4@10/100Mbps RJ-45 and 2@10Mb multi-mode FX-ST “twist lock” Combo Module

the 100Mb combo module with the exception of 10Mb speed at the ST fiber module.

fiber optic cable distances up the IEEE-standard 10Mbps distance limits, i.e., typically

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The

100Mbps distance limits, i.e., typically 2km at full-duplex and 412m at half-duplex.

Each port has an Activity (ACT) LED indicating packets being received, a

Each port has an Activity (ACT) LED indicating packets being received, a

dual speed copper ports. The ST-connector functions as a fiber optic transceiver to

segments. When installed in a Magnum 6K32T & 6K32TRC Managed Switch, the

10/100 LED indicates the speed, if the LED is ON, 100Mbps if it is OFF, 10Mbps.

support 100BASE-FX network segments. When installed in a Magnum 6K32T &

10/100 LED indicates the speed, if the LED is ON 100Mbps if it is OFF 10Mbps.

4 Port@ 10/100Mbps and 2 @100 Mb ST Fiber Port

port and the fiber port supports fiber optic cable distances up the IEEE-standard

4 FULL/HALF

10/100 LK

F/H ACT

2 6 TX RX TX LK RX LK

1 3 5 7

6KP6-RJMST,

ACT

F/H

LINK 2

ACTIVITY

ACT

F/H

2km at full-duplex and half-duplex.

module is equipped with dual-

mode ST-type connectors and

10/100Mbps and fiber optic

ports at 100MB. The Combo

lock” Combo

RJMST is a combo 6 port

module of RJ-45’s at

Module

10/100 · The Magnum 6KP6-

Page 57 of the GarrettCom 6K32T user manual — 6KP4-RJ10MST,
Page 57 · click to enlarge
Page 57
GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 57)
Fig. 26 · Figure 4: A multicast traffic through a 6K32TRC Swit…

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 57)
Fig. 27 · Figure 4: A multicast traffic through a 6K32TRC Swit…

hub to connect to the switch through 10Mb fiber ports. It supports distances according to

5.2.1c 6KP4-FLSTFX, 2@10Mb and 2@100Mb multi-mode FX-ST “twist lock” Module

the 10Base-FL standard i.e, 2Km distance for multi-mode fiber. (Single-mode for 10Km

5.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module

multi-mode fiber module and in combine 4 ST-Fiber ports. All four fiber ports are ST

The Magnum 6KP4-FLSTFX is a combo fiber module with two 10Mb + two 100Mb

6K32TRC switch. They also provide a convenient way for the half duplex

4 Port@ 10Mb ST Fiber Port

4 Port@ 10Mb ST Fiber Port

6KP4-RJ10MST,

6KP4-RJ10MST,

FULL/HALF

distance may be available as a special order).

full-duplex mode when lit (or

has an Activity (ACT) LED

received, a Link (LK) LED

connectivity with the remote

their legacy 10Mb network

Fiber ports. All four fiber

and configured as 10Mb

The 10Mb ST-fiber ports

allow the user to connect

to the Magnum 6K32T &

fiber module with 4 ST-

ports are ST connectors

Half-duplex by default.

is a 10Mb multi-mode

device when lit, and

half-duplex if off).

Show 5 more labels / short text on this page
Each port · The Magnum 6KP4-F10ST · FDX/HDX LED indicating · indicating packets being · indicating proper
Page 58 of the GarrettCom 6K32T user manual — 6KP6-RJMSC,
Page 58 · click to enlarge
Page 58

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

Full duplex for the 100Mb fiber. The 10Mb ST-fiber ports allow the user to connect their

While the functionality of these two modules is essentially the same, the 6KP6-

legacy 10Mb network to the Magnum 6K32T & 6K32TRC switch. They also provide a

devices. It supports distances according to the 10Base-FL standard i.e, 2Km distance for

multi-mode fiber. (Single-mode for 10Km distance may be available as a special order).

received, a Link (LK) LED indicating proper connectivity with the remote device when

connectors and configured as 10Mb Half-duplex by default for 10Mb fiber and 100Mb

ports. Whereas the 100Mb ST module allow to connect the 100Mb demand of Switch

convenient way for the half duplex hub to connect to the switch through 10Mb fiber

lit, and FDX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).

4 Port@ 10/100Mbps and 2 @100 Mb SC Fiber Port

Each port has an Activity (ACT) LED indicating packets being

5.2.2. 6KP6-RJMSC 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-SC “snap-in” Fiber connector

RJMSC is equipped with an SC-type "snap-in" connector instead of an ST-type.

F/H ACT

4 FULL/HALF

10/100 LK

2 6 TX RX TX LK RX LK

1 3 5 7

FDX / HDX and 10/100 operation, and the same face-plate lettering.

6KP6-RJMSC,

F/H ACT

F/H

LINK 2

ACTIVITY

ACT

transceivers all in one module. This

is similar to the 6K6-RJMST. It has

module equipped with 4 10/100Mb

RJMSC is also a Combo 6 Port

RJ-45 ports along with 2 multi-

activity (ACT), Link (LK), and

the same LEDs indicating port

mode 100Mbps fiber optic

10/100 · The Magnum 6KP6-

Page 59 of the GarrettCom 6K32T user manual — ACTIVITY
Page 59 · click to enlarge
Page 59

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

operates on copper at the 100m distance. The Fiber is single-mode and cable lengths can

Link (LK) LED that indicates proper connectivity with the remote device when lit, and a

ports and 2 Single-mode (Long Reach) SC-type connectors. It provides a combination of

5.2.3 6KP6-RJSSC 4@ 10/100Mbps RJ-45 Ports and 2@100Mbps single-mode FX-SC-type,

5.2.4 6KP6-RJSSCL 4 @ 10/100 Mb copper port and 2@100Mbps single-mode FX-SC-type, “snap-in” connector

The Magnum 6KP6-RJSSC is also a Combo module equipped with 4 dual speed copper

and Fiber functions in one module of the 6K32T & 6K32TRC Switch supporting four

The 6KP6-RJSSC, when installed in a Magnum 6K32T & 6K32TRC Switch

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The

distinguish the single-mode 6 K6-RJSSC from the multi-mode 6K6-RJMSC, the label

The 6KP6-RJSSC, when installed in a Magnum 6K32T & 6K32TRC Switch

has copper supporting the 100m distance and Fiber supporting single-mode fiber cable

Each port has an Activity (ACT) LED indicating packets being received, a

supporting four Copper and two single-mode (Long-Reach) fiber network segments.

10/100 LED indicates 100Mbps speed when lit and 10Mbps speed when off. To

copper and Fiber functions in one module to the 6K32T & 6K32TRC Switches,

4 Port@ 10/100Mbps and 2 @100 Mb SSC Fiber Port

4 FULL/HALF

10/100 LK

F/H ACT

2 6 TX RX TX LK RX LK

1 3 5 7

6KP6-RJMSSC,

lengths of as much as 40+ Km (see Power Budget, Section 4.5)

ACT

F/H

“Sgl. M.” is at the top of the faceplate of the 6K6-RJSSC.

LINK 2

be as much as 25+ Km (see Power Budget, Section 4.5)

Copper and two single-mode fiber network segments.

ACTIVITY

ACT

F/H

equipped with 4 dual speed

mode SC-type connectors. It

copper ports and 2 Single-

is also a Combo module

Show 6 more labels / short text on this page
10/100 · The Magnum 6KP6-RJSSC · through combining copper · provides an advantage · “snap-in” · connector
Page 60 of the GarrettCom 6K32T user manual — 6KP8-MTRJ,
Page 60 · click to enlarge
Page 60

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The Magnum 6KP6-RJ10ST is also a Combo module equipped with 4 dual speed copper

5.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factor

10/100 LED indicates the speed for the copper port, which is 100Mbps when the LED is

The 6KP6-RJ10ST, when installed in a Magnum 6K32T & 6K32TRC Switch

allow to connect the legacy network of 10Mb requirement in the network. Each port has

an Activity (ACT) LED indicating packets being received, a Link (LK) LED indicating

Link (LK) LED indicating proper connectivity with the remote device when lit, and a

5.2.4a 6KP6-RJ10ST 4 @ 10/100 Mb copper port and 2@10Mbps multi-mode FL-ST-type, “twist-lock” connector

ports and 2 multi-mode 10 Mb fiber ST-type connectors. It provides a combination of

has copper supporting the 100m distance and Fiber supporting multi-mode fiber cable

proper connectivity with the remote device when lit, and a FDX/HDX LED indicating

speed for the copper port, which is 10Mbps when the LED is ON and 10 Mb when the

8 Port@ 100Mbps Multi-Mode Fiber port

Each port has an Activity (ACT) LED indicating packets being received, a

FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). The

full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the

FULL/HALF 1 ACTIVITY

“small-form-factor”

copper and Fiber functions in one module to the 6K32T & 6K32TRC Switches,

ACT

F/H

ACT

F/H

ACT

F/H

ACT

F/H

F/H LK LK LK LK

1 3 5 7

2 4 6 8 LK

supporting four Copper and two 10Mb of ST fiber network segments.

6KP8-MTRJ,

LINK

ACT

F/H

ACT

ACT

ACT

F/H

F/H

ON and 10 Mb when the LED is OFF.

MTRJ-type connector. It looks

almost like an RJ-45 port, but it

is black in color. The MT-RJ’s

optic 8-port module equipped

choice for 100Mbps “fiber-to-

MTRJ is a multi-mode fiber

connection make it a good

small size and ease of

LED is OFF.

Magnum 6KP8- · with a small-form-factor · the-desktop” Ethernet

Page 61 of the GarrettCom 6K32T user manual — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2
Page 61 · click to enlarge
Page 61

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The functionality of this 100BASE-FX multi-mode 8 Port module is essentially

connector supports fiber optic cable distances up to the IEEE-standard 100Mbps distance

limits, i.e., typically 2km at full-duplex and 412m at half-duplex. The 10Mb Multi-mode

connectivity. When installed in a Magnum 6K32T & 6K32TRC Switch, it supports fiber

optic cable distances up the IEEE-standard 100Mbps distance limits, i.e., typically 2km

the same as the ST and SC-types. It has the same LEDs per port indicating port activity

The 6KP6-RJ10ST is a combo module with two different kinds of fiber flavor

with two different speeds. The top four ports of MTRJ Small form factor fiber support at

5.2.5a 6KP6-MT10ST, 4 @100Mb multi-mode FX , MTRJ Small-Form- Factor and 2@ 10Mb Multi-mode ST-Fiber port

100Mb full-duplex, whereas the bottom two ports multi-mode ST-Fiber support 10Mb

half-duplex. This combo module provides more flexibility to the user to connect their

When installed in a Magnum 6K32T & 6K32TRC Switch, the 100Mb MTRJ

ST-Fiber connector supports the standard fiber optic distance limit of 2Km at Full and

The functionality of this 100BASE-FX multi-mode 4 port module is

legacy 10Mb fiber as well as 100Mb to the Magnum 6K32T & 6K32TRC Switch.

essentially the same as the ST and SC-types. It has the same LEDs per port

indicating port activity (ACT), Link (LK), and FDX or HDX operation

(ACT), Link (LK), and FDX or HDX operation.

at full-duplex and 412m at half-duplex.

Half-duplex both.

Page 62 of the GarrettCom 6K32T user manual — MTRJ Small-Form-Factor
Page 62 · click to enlarge
Page 62
GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 62)
Fig. 28 · Figure 4: A multicast traffic through a 6K32TRC Swit…
GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 62)
Fig. 29 · Figure 4: A multicast traffic through a 6K32TRC Swit…

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

3 2 4 6 8 LK

5.2.7 6KP8-MLC, 8 ports @ 100Mbps multi-mode LC connector SmallForm Factor

indicating packets being received, a Link (LK) LED indicating proper connectivity with

the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit

5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX ,

4 Port@ 10/100Mbps & 4 port @ 100Mbps

8Port@ 100Mbps MLC Ports -

8Port@ 100Mbps MLC Ports -

wiring closets while providing the advantage of “future-proof” fiber optic technology.

The cable end is a “plug-in” connector with both fiber strands terminated in

one housing that cannot be improperly inserted. Each port has an Activity (ACT) LED

The compact size of the LC Connector reduces the size of wiring panels in

412m at half-duplex.

standard distances as mentioned on 5.2.3. and the LEDs also act similarly.

6KP8-45MT

distance limits, i.e., typically 2km at full-duplex and

Magnum 6KP8-MLC is a eight-port multi-

6K32T & 6K32TRC Switch, it supports fiber optic

cable distances up to the IEEE-standard 100Mbps

mode fiber LC connector “small-form-factor”

desktop links. When installed in a Magnum

MTRJ Small-Form-Factor

used primarily in 100Mbps fiber-to-the-

copper and fiber (Small Form Factor)

of placing more ports on one module.

10/100 RJ-45 ports and 4 MTRJ fiber

MTRJ connectors give an advantage

The 6KP8-45MT is equipped with 4

When installed in a Magnum 6K32T

& 6K32TRC Switch, it supports the

MTRJ type ports. The small size of

Module is a combo module with

(or half-duplex when off).

ports.

Multi-Mode Fiber port · The Magnum 6KP8-45MT

Page 63 of the GarrettCom 6K32T user manual — 5.2.9 6KP8-RJ45 (Twisted Pair),
Page 63 · click to enlarge
Page 63
GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 63)
Fig. 30 · Figure 4: A multicast traffic through a 6K32TRC Swit…

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 63)
Fig. 31 · Figure 4: A multicast traffic through a 6K32TRC Swit…

connector is shielded to minimize emissions and will allow both unshielded twisted pair

equipped with a Media Dependent Auto-Crossover (MDI-X) switch, which controls all

5.2.8 6KP8-45LC, Combo 4@ 100Mbps multi-mode -LC small-form factor and 4@ 10/100 Mbps RJ-45 Connector

(UTP) and shielded twisted pair (STP) cable connections. The 6KP8-RJ45 module is

4 Port@ 10/100Mbps & 4 port @ 100Mbps

When installed in a Magnum 6K32T & 6K32TRC Switch, it supports the standard

distances as per mentioned on 5.2.8. and the LEDs also acts similarly as mentioned

4 FULL/HALF

8 Port@ 10/100Mb Copper ports

Multi-Mod LC Fiber port

6KP8-RJ45,

ACTIVITY

connectors allows an advantage of

having more ports on one module.

45LC Module is a combo module

with a combination of copper and

The 6KP8-45LC is equipped with

type ports. The small size of LC

4 10/100 RJ-45 ports and 4 LC(

Small form factor) multi-mode

Fiber (Small Form Factor) LC

twisted pair segments of any

equipped with an eight-port

RJ-45 connector, and offers

10/100 full / half-duplex

on each port. The RJ-45

5.2.9 6KP8-RJ45 (Twisted Pair),

10/100Mb 8-Port

standard length. It is

fiber ports.

above.

Show 4 more labels / short text on this page
The Magnum 6KP8- · The 6KP8-RJ45 · module supports Ethernet · auto-negotiating capability
Page 64 of the GarrettCom 6K32T user manual — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2
Page 64 · click to enlarge
Page 64

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

Auto-crossover (MDIX), which allow the RJ-45 ports to automatically Link with any RJ-

could produce kigh (greater than 2500V ) levels of ground potential rise (GPR)

during line-to-ground fault conditions. The 6K32 passes the 1613specifications

Each port requires at least 15watts to power up the PoE PD devices. In this Fig. the top 8-

with mix –n-match with fiber modules. Please check the ordering information Sec.1.2 for

ports for cascaded connection. This feature eliminates the need for a special twisted pair

45 port are per the standard for up-links using twisted pair wiring, i.e., the transmit and the receive pairs are exchanged: 1 = transmit+, 2 = transmit-, 3 = receive+, 6 =

for zero packet loss with fiber ports & with RJ45 ports used as indicated here.

5.2.10a. New PoE (Power Pass-through), model P6KP8V-RJ45 (MDIX), 10/100Mb 8-port The PoE RJ-45 ports act similar to regular RJ-45 ports, except they have

IEEE802.3af PoE standard. The Power Pass-through PoE modules are totally dependent

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off), and a

users twisted pair wiring1 = receive+, 2 = receive-, 3 = transmit+, 6 = transmit-,

other pins not used. When the TP crossover push-button is UP, the pins of the RJ-

telecommunication multiplexers installed in close proximity (i.e., less than 2

upon the powerful -48VDC input power supply to support more RJ-45 (10/100) ports.

RJ45 ports are enhanced with POE option The 8-RJ45 POE modules are also available

Each port has an Activity (ACT) LED indicating packets being received, a

Link (LK) LED that indicates proper connectivity with the remote device when lit, a

45 device and eliminate the use of cross-over cable. The RJ-45 pins normally (TP crossover switch) are per the standard for hubs-to-

substation applications to interface to field devices across distances which

advises that, for substation applications, the RJ-45 ports are intended for

meters or 6.5ft) to the 6K32. It is not recommended to use these ports in

capability of providing power on each port to power up the PD devices, per the

connectivity to other communication equipment such as routers or

“10/100” LED indicating 100Mb when lit (or 10 Mbps when off).

crossover cable when connecting to a hub or another switch.

all the various P6K PoE modules option.

receive-, other pins not used.

Page 65 of the GarrettCom 6K32T user manual — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2
Page 65 · click to enlarge
Page 65

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

PoE LED is ON when connected properly to an 803.af compliant PD device on that port.

devices. The PoE LED is ON when the attached PD is drawing power from the

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

through, so the 48VDC power source must be strong enough to provide power

to the 6K switch and to all the 8 RJ-45 ports with PD devices connected (up to

  • In the case where the 48VDC power in not internally connected and no power

IEEE802.3af PoE standard. Only 4 x RJ-45 (10/100) ports maxm. support POE(Power

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

  • For non-PoE devices connected, the PoE port will act as a normal RJ-45 port

5.2.10b. New PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-port

The LEDs on 6KP8-RJ45- PoE modules are slightly different compared to

is coming to the PoE ports for some reason, all the PoE port LEDs are ON

simultaneously to indicate a trouble condition. The ports will still operate

The PoE RJ-45 ports act similar to regular RJ-45 ports, except they have

When non-PoE devices are connected, the PoE LED is OFF. PoE does not affect

  • For PoE devices, each RJ-45 PoE port supports only 802.3af complaint
  • The PoE ports in Magnum 6K’s with 48VDC power input act as a pass-

capability of providing power on each port to power up the PD devices, per the

and the PoE LED is OFF. No power is being sent out from the port.

that is marked as LINK/ACT, as shown in the diagram.

properly for data traffic.

operation of Ethernet data traffic.

15 watts per PoE port).

port.

PoE LEDs Summary

Page 66 of the GarrettCom 6K32T user manual — F/H
Page 66 · click to enlarge
Page 66

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

option whereas as bottom 4- RJ-45 are normal MDIX ports. The 4-RJ45 POE module are

devices. The PoE LED is ON when the attached PD is drawing power from the

PoE LED is ON when connected properly to a 803.af compliant PD device on that port.

When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

through, so the 48VDC power source must be strong enough to provide power

to the 6K switch and to all the 8 RJ-45 ports with PD devices connected (up to

Inside) option in one 6K-unit. In this Fig. the top 4-RJ45 ports are enhanced with POE

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

  • For non-PoE devices connected, the PoE port will act as a normal RJ-45 port

10/10 L 1

3 2 4 6 LK

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to

GarrettCom 6K32T — 10/10 L 1 diagram (page 66)
Fig. 32
  • For PoE devices, each RJ-45 PoE port supports only 802.3af complaint
  • The PoE ports in Magnum 6K’s with 48VDC power input act as a pass-

6 Port@10/10Mbps and 2 port @100Mb Multi-Mode Fiber port

4 FULL/HALF

also available with mix –n-match with fiber modules. Please check the ordering

2 1 3 5 7 10/10 0 LK/ACT 1

2 1 3 5 7 10/10 0 LK/ACT 1

and the PoE LED is OFF. No power is being sent out from the port.

F/H AC

ACT

ACT

F/H

F/H

6KP8V6KP8 -45-2MT

information Sec.1.2. for all the various PI6K PoE modules option.

LINK 2

8 Port@ 10/100Mb POE Copper ports

8 Port@ 10/100Mb POE Copper ports

ACTIVITY

that is marked as LINK/ACT, as shown in the diagram.

F/H

PI6KP8V-45RJ

PI6KP8V-45RJ

48VDC power in not internally connected and

condition. The ports will

still operate properly for

15 watts per PoE port). • In the case where the

no power is coming to

the PoE ports for some

reason, all the PoE port

traffic is not affected by PoE.

data traffic.

port.

Show 5 more labels / short text on this page
10/100 · 10/100 · simultaneously to · indicate a trouble · LEDs are ON
Page 67 of the GarrettCom 6K32T user manual — ACT
Page 67 · click to enlarge
Page 67

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The Magnum 6KP8-45-2MT eight port Module is a combo module with copper

- 6 Port@ 10/100Mbps & 2 port @ 100Mbps

GarrettCom 6K32T — - 6 Port@ 10/100Mbps & 2 port @ 100Mbps diagram (page 67)
Fig. 33 · - 6 Port@ 10/100Mbps & 2 port @ 100Mbps

to-switch and switch-to- switch applications.

IEEE 802.3z standard 1000Mbps distance

5.2.11 6KP8-45-2MT, 6@ 10/100Mbps RJ-45 and 2@100Mb multi-mode FX , MTRJ Small-Form-Factor

equipped with six 10/100 RJ-45 ports and two 100Mb MTRJ fiber ports. When installed

The Magnum GBIC-SXSC is a multi-mode Gigabit fiber connector

fiber ports are most popular as server-

It supports cable distances up to the

and fiber (Small Form Factor) MTRJ type ports. The small sizes of MTRJ connectors

5.2.12 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector

give an advantage of placing more fiber ports on one module. The 6KP8-45-2MT is

equipped with SC type connectors and can be easily snapped in and out. The Gigabit

When installed in a Magnum 6K32T & 6K32TRC Switch, it supports the standard

in a Magnum 6K32T & 6K32TRC Switch, it supports the standard distances as

limits, i.e., 550m at full duplex.

2SLC is equipped with 6 10/100 RJ-45 ports and 2 Single-mode fiber ports.

1@ 1000Mb Fiber SC + 4@10/ 100Mb

F/ ACT

distances as mentioned on 5.2.4. and the LEDs also act similarly.

10/100 L

1 3 5 7

mentioned on 5.2.3. and the LEDs also act similarly.

TX RX LK

45SLC eight port Module is a combo

module with copper and fiber (Small

Form Factor) LC type fiber ports.

give an advantage of placing more

ports on one module. The 6KP8-45-

5.2.11a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor

The small size of LC connectors

ACT

F/

Single-Mode Fiber port · The Magnum 6KP8-

Page 68 of the GarrettCom 6K32T user manual — 5.2.12a GBPM-2OTX (Two Gigabit option)
Page 68 · click to enlarge
Page 68
GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 68)
Fig. 34 · Figure 4: A multicast traffic through a 6K32TRC Swit…

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

removing the transceiver, press the clips on either side of the transceiver at the same time

provide a wide option of choice for various Gigabit transceivers covering a long range of

standard GBICs to provide Gigabit (Gb) transceivers media flexibility. GBIC models are

available for both multi-mode (550m) and single-mode (10, 25, 40, 70) km fiber options,

The GBIC transceiver has been offered in the modular slot with multiple options as per

the user requirement. The two Giga port has been offered as GBPM-2OTX (fiber or RJ-

45), whereas the single Gigabit module comes in flavor of G+2 (100Mb fiber ports) or G+4(10/100 RJ-45 ports) as shown in the above figure.

Each port has an Activity (ACT) LED indicating packets being received and a

GarrettCom 6K32T — Figure 4: A multicast traffic through a 6K32TRC Switches using IGMP-L2 diagram (page 68)
Fig. 35 · Figure 4: A multicast traffic through a 6K32TRC Swit…

distance. The GBPM-2OTX also meets the requirement for those applications where a

The 6K16-Series Modules provide a GBIC opening for insertion of industry-

The GBIC transceiver is fastened using snap-in clips. Insert the transceiver

managed Gigabit media converter is required. The two Gigabit slot can be filled with

(take care to insert it the right way up, arrows on top) until it clicks in space. While

Link (LK) LED indicating proper connectivity with the remote device when lit.

and Gigabit copper as well, with new models appearing often.

5.2.12a GBPM-2OTX (Two Gigabit option)

module). While up to two Gigabit modules

(maxm.) can be configured in the modular

copper/Fiber or mix as per the application.

The Magnum 6K16-Series offered a wide

modular slot via GBPM-2OTX (2 x Giga

slot for GBPM-2OTX. The Dual Gigabit

selection of Gigabit speed with multiple

choice of copper or Fiber or mix for the

port option for the modular slot

and pull the transceiver out.

Page 69 of the GarrettCom 6K32T user manual — F/
Page 69 · click to enlarge
Page 69

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

with SC type connectors and can be easily snapped in and out. The Gigabit fiber ports are

The two Giga port has been offered as GBPM-2OTX (fiber or RJ-45), whereas the single

Two screws underneath the front panel hold the 6KM-BLNK in place.

Each port has an Full and Half Duplex (F/H) Activity, (ACT) LED indicating

The Magnum GBIC-LXSC is a single-mode Gigabit fiber connector equipped

Gigabit module comes in flavor of G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber ports)

Each port has an Activity (ACT) LED indicating packets being received and a link (LK)

5.2.12b GBIC-LXSC Gigabit fiber (1000Mb), multi-mode SC Connector

packets being received and a Link (LK) LED indicating proper connectivity with the

most popular as server-to-switch and switch-to-switch applications. It supports cable

distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e., 10,25, 40 or

LED indicating proper connectivity with the remote device when lit.

70Km at full duplex, and depend upon the Gigabit modules used.

1@ 1000Mb Fiber SC + 2@ 100Mb SC

TX LK RX

ACT

F/

TX RX L

as shown below in the above figure.

TX RX LK

blank face plate or cover plate that

maintain proper cooling air flow,

must be installed in any empty

6K32T & 6K32TRC PM slot to

The 6K8-BLNK is a

ACT

ACT

5.2.13 6KM-BLNK

remote device when lit

F/

F/

safety, etc.

Page 70 of the GarrettCom 6K32T user manual — 6.1 Before Calling for Assistance
Page 70 · click to enlarge
Page 70

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

INSTALLATION, Section 3.0); the operation is also straightforward and is discussed in

suggestions listed below prior to contacting your supplier. However, if you are unsure of

3. Make sure that an AC power cord is properly attached to each Magnum 6K32T
4. If the problem is isolated to a network device other than the Magnum 6K32T &

corrected. If not, go to Step 5 below. If the problem is corrected, the Magnum

6K32T & 6K32TRC Switch and its associated cables are functioning properly.

the procedures described in this section or if the Magnum 6K32T & 6K32TRC Switch is

1. If difficulty is encountered when installing or operating the unit, refer back to

& 6K32TRC Switch unit. Be certain that each AC power cord is plugged into

5. Always check your Switch configuration, specially Auto-negotiation behavior

intended to help locate, identify and correct these types of problems. Please follow the

the Installation Section of the applicable chapter of this manual. Also check

to make sure that the various components of the network are interoperable.

replaced with a known good device. Verify whether or not the problem is

a functioning electrical outlet. Use the PWR LEDs to verify each unit is

6K32TRC Switch product, it is recommended that the problem device be

consistently high performance in all network environments. The installation of a

Should problems develop during installation or operation, this section is

not performing as expected, do not attempt to repair the unit; instead contact your

2. Check the cables and connectors to ensure that they have been properly

impaired during installation. (About 90% of network downtime can be

All Magnum Ethernet products are designed to provide reliability and

connected and the cables/wires have not been crimped or in some way

Magnum 6K32T & 6K32TRC Switch is a straightforward procedure (see

with other connected device to have proper setup tested.

supplier for assistance or contact GarrettCom Customer Support.

attributed to wiring and connector problems.)

6.1 Before Calling for Assistance

6.0 TROUBLESHOOTING

receiving power.

Section 4.

Page 71 of the GarrettCom 6K32T user manual — 6.2 When Calling for Assistance
Page 71 · click to enlarge
Page 71

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

All returns for repair must be accompanied by a Return Material Authorization

5. If the problem continues after completing Step 4 above, contact your supplier
4. A record of changes that have been made to your network configuration prior
3. It is useful to include other network equipment models and related hardware,

including personal computers, workstations, terminals and printers; plus, the

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

number(s). Include the date(s) that you purchased the products from your

c. The components involved in the problem; (complete Network diagram

d. Any particular application, environment, power spike that, when used,

to the occurrence of the problem. Any changes to system administration

of the Magnum 6K32T & 6K32TRC Switch unit or if unknown, contact

GarrettCom, Inc.by fax, phone or email (support@garrettcom.com) for

1. A complete description of the problem, including the following points:
2. An accurate list of GarrettCom product model(s) involved, with serial

6.3 Return Material Authorization (RMA) Procedure

(RMA) number. To obtain an RMA number, please use this URL -

Please be prepared to provide the following information.

Name and phone number of your contact person.

Please have the following information readily available:

procedures should all be noted in this record.

a. The nature and duration of the problem;

various network media types being used.

b. Situations when the problem occurs;

Name of your company / institution

6.2 When Calling for Assistance

appears to create the problem;

assistance.

supplier.

Your shipping address · preferred)

Page 72 of the GarrettCom 6K32T user manual — Attn.: Customer Service
Page 72 · click to enlarge
Page 72

sheet or bag for shipping protection. ( You may retain all connectors and this

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic

material. This material may cause electro-static shock damage to the unit.

CAUTION : Do not pack the unit in Styrofoam "popcorn" type packing

GarrettCom will carefully test and evaluate all returned products, will repair products

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

GarrettCom, Inc. warrants its products to be free from defects in materials

that are under warranty at no charge, and will return the warranty-repaired units to

the sender with shipping charges prepaid (see Warranty Information, Appendix A,

units under warranty. Testing and repair of product that is not under warranty will

Should you need to ship the unit back to GarrettCom, please follow these

GarrettCom reserves the right to charge for the testing of non-defective

and workmanship for a period of three (3) years from the date of shipment by

for complete details). However, if the problem or condition causing the return

3. GarrettCom is not responsible for your return shipping charges.

Failure symptoms, including a full description of the problem.

cannot be duplicated by GarrettCom, the unit will be returned as:

APPENDIX A: WARRANTY INFORMATION

Packing List Number (or Sales Order Number)

6.4 Shipping and Packaging Information

No Problem Found.

Serial Number (or Invoice Number)

47823 Westinghouse Dr.

Attn.: Customer Service

GarrettCom, Inc.

result in a customer (user) charge.

Installation Guide.)

4. Ship the package to:

GarrettCom.

instructions:

Fremont, CA 94539-7437 · Date of installation · Product name

Page 73 of the GarrettCom 6K32T user manual — POWER
Page 73 · click to enlarge
Page 73

B1.0 SPECIFICATIONS FOR MAGNUM 6K32T & 6K32TRC SWITCHES, DC

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The -48VDC, 24VDC and 125VDC power options are designed using diodes

inside on each DC power input line behind the two external power connection terminals,

functions of Magnum 6K32T & 6K32TRC Switch -48VDC, 24VDC and 125VDC

B2.0 -48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION

replace components in the products that prove to be defective at no charge other

product has been damaged by misuse, misapplication, or as a result of service or

This warranty will not be effective if, in the opinion of GarrettCom, the

Please complete the warranty card as this acts as a product registration,

GND GND CHASSIS

than shipping and handling, provided that the product is returned pre-paid to

inspecting any product returned for warranty repair which turns out not to be

With the exception of the power supply, all specifications and

FUSE +

During this warranty period, GarrettCom will repair or, at its option,

Power ConsumptionSame as for AC models (see Section 1.1)
Power ConsumptionSame as for AC models (see Section 1.1)
Power ConsumptionSame as for AC models (see Section 1.1)

HUB POWER SWITCH

SUPPLY

GarrettCom reserves the right to make a charge for handling and

Power Supply (Internal 125 VDC Option) Industrial Applications

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

Power Supply (Internal 24 VDC Option) Industrial Applications

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

and mail it to GarrettCom within two weeks of your purchase.

APPENDIX B : Internal DC Power Supply Options

models are identical to those listed in the main manual.

Input Voltage88 - 150 VDC
Input Voltage36 - 70 VDC
Input Voltage20 - 36 VDC

A+

A-

modification other than by GarrettCom.

Power Supply (Internal -48VDC Option)

so that the power from an external

source can only flow into the hub.

This allows the Switch to operate

only whenever DC power is

GarrettCom.

faulty.

POWER

Page 74 of the GarrettCom 6K32T user manual — B4.0 INSTALLATION
Page 74 · click to enlarge
Page 74

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The manual power “On-Off” Switch (optional) is used for powering the unit on

Magnum 6K32T & 6K32TRC Fiber Switches are easily installed in a variety of

The –48VDC solution is particularly useful in the telecommunication industry,

other communication companies. In addition, many high availability equipment services,

facilities often use a battery backup system to maintain operations in the event of a power

environment, where it is common facilities to operate on 24VDC or 125VDC power. The

Switch, its internal power supply, nor will it blow the fuse in the internal power supply.

applications where -48VDC, 24VDC and 125VDC power is used as the primary power

where it is common for facilities to operate on -48VDC power. Such companies include

source. The- 48VDC, 24VDC and 125VDC power configuration provides an Ethernet

regular and wireless telephone service providers, Internet Service Providers (ISPs) and

This section describes the installation of the -48 VDC, 24VDC and 125VDC

power source leads to the -48 VDC, 24VDC and 125VDC power terminal block on the

6K32TRC is located on the rear of the unit and is equipped with three (3) screw-down

The 24VDC and 125VDC solution are particularly useful in the Industrial

125VDC solution is mainly used in power utilities, such as electrical substations, electrical generating plants, etc. The 24VDC applications are mainly in the Industrial

correctly applied to the two inputs. It protects the Switch from incorrect DC input

Figure B4.0-48VDC Terminal Block on Magnum 6K32T & 6K32TRC-

connections. An incorrect polarity connection, for example, will neither affect the

such as broadcasters, publishers, newspaper operations, brokerage firms and other

failure. It is also frequently used for computer system backup, management and

environment, such as factory floor, HVAC equipment, military equipment, etc.

In this picture, the -48VDC terminal block on the Magnum 6K32T &

lead posts. It is similar for 24VDC and 125VDC options on Magnum 6K32T &

networking solution utilizing a special power supply in a Managed Switch.

B3.0 APPLICATIONS FOR DC POWERED SWITCHES

6K32TRC. The leads are identified as negative (-),

and off when it is placed into or taken out of service.

Magnum 6K32T & 6K32TRC’s. (see figure at right).

positive (+), and chassis ground (GND).

operations monitoring equipment.

B4.0 INSTALLATION

48VDC

Page 75 of the GarrettCom 6K32T user manual — B6.0 ORDERING INFORMATION
Page 75 · click to enlarge
Page 75

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage

1. Minimum 18AWG cable for connection to a Centralized DC power source. 2. Minimum 14AWG cable for connection to a earthing wiring. 3. Use only with Listed 10 A circuit breaker provided in building installation. 4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.
5. Fastening torque of the lugs on the terminal block: 9 inch-pound max. 6. Centralized DC Power Source cable securement, use at least Minimum 14AWG four cable ties to secure the cable to the rac,k at least 4 inches apart, with the

To order the optional -48VDC power supply factory installed, add a suffix of “-

The actual connection procedure is very straightforward. Simply connect the

An ON-OFF manual switch is optional for DC power. This can be used to cut

-48VDC” after the product’s standard model # Example: Magnum 6K32R & 6K32T &

standard model #. ExampleMagnum 6K32T & 6K32TRC24VDC, Magnum 6K32T

ground, so the user may elect to Ground either + or - terminal to suit the customer’s

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

off power connections and as a RESET for the Magnum 6K32T & 6K32TRC Switch.

Similarly to order the optional 24VDC or 125VDC industrial specific power

leads to the Magnum unit, beginning with ground. Ensure that each lead is securely

supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s

Operation of Magnum 6K32T & 6K32TRC Switches with the optional -

48VDC, 24VDC and 125VDC power supply is identical to that of the standard AC-

lead from 48V or –48V supply must be connected to the post labeled “+”.

first one located within 6 inches of the terminal block.

B4.1 UL Requirements for DC-powered units

B6.0 ORDERING INFORMATION

B5.0 OPERATION

& 6K32TRC-125VDC.

6K32TRC -48VDC.

powered models.

tightened.

use.

Page 76 of the GarrettCom 6K32T user manual — SWITCH
Page 76 · click to enlarge
Page 76

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

supply, all specifications and configuration options for the Magnum 6K32T & 6K32TRC -

48VDC, 24VDC and 125VDC models with this Dual-Source option are identical to those listed in the Magnum 6K32T & 6K32TRC Fiber Switches Installation and User Guide,

GNDTerminal for “earth” or ground wire connection to the hub chassis
GNDTerminal for “earth” or ground wire connection to the hub chassis
GNDTerminal for “earth” or ground wire connection to the hub chassis

24VDC and 125VDC Dual-Source Option units is identical to the standard AC-powered models. Refer to the main sections of

DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”

125VDC Dual-Source option The 6K32T & 6K32TRC & 6K32-Switch models with the internal -48VDC,

24VDC and 125VDC Dual-Source power supply are designed for installations where a battery plant is the power source, and where two separate power sources are utilized in

FUSE +

GND CHASSIS

With the exception of the dual DC input power connections and the power

SUPPLY A+

HUB

GND

C2.0 MAGNUM 6K32T & 6K32TRC & 6K32, with -48VDC, 24VDC and

C1.0 SPECIFICATIONS - FOR MAGNUM 6K32T & 6K32TRC FIBER

Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-24V)

The functionality of the Magnum 6K32T & 6K32TRC Switch -48VDC,

Power Supply (Internal, -48VDC Dual-Source, model # Dual-Src-48V)

Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)

InputTwo separate sources, each at 88 - 150 VDC

APPENDIX C: Internal DC Dual-Source Power Option

InputTwo separate sources, each at 36 - 70 VDC
InputTwo separate sources, each at 20 - 36 VDC

order to increase operational uptime and to simplify maintenance.

including Appendix B “Internal DC Power Supply Option”

Please refer to Section 6.0 for troubleshooting

B+

A-

B-

this Installation and User Guide for a

B7.0 TROUBLESHOOTING

detailed description of the Magnum

6K32T & 6K32TRC Switches.

SWITCH

Page 77 of the GarrettCom 6K32T user manual — C5.0 INSTALLATION
Page 77 · click to enlarge
Page 77

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

source can only flow into the unit. This allows the unit to operate whenever DC power is

d) Reverse polarity connections, if they should accidentally occur on either input, will not damage

Terminal Block on a Magnum 48VDC with Dual-Source option

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage

a) The Switch unit can receive power from either input, “A” or “B”. The hub will normally draw

125VDC dual source leads to the -48VDC, 24VDC 7 125VDC power terminal block on the Magnum 6Ks Switch (shown in Figure )

125VDC are similar. Figure C5.0-48VDC Dual-Source, wiring connections to the External

b) The Switch unit will not allow power to flow from a higher voltage input to a lower voltage

c) When one correct DC input is present, the Switch will receive power if the other DC input is

the Switch or power supply internally (nor will it blow the fuse in the internal power supply)

e) The Switch will not receive power (and will not work) when both inputs are simultaneously

The -48VDC terminal block on the Magnum 6K32T & 6K32TRC Switch, as shown in

ground, so the user may elect to Ground either + or - terminal to suit the customer’s

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

chassis on each DC power input line. A diode is placed in each of the four input lines

(behind the four external power connection terminals) so that power from an external

The Dual-Source DC power option is designed using diodes inside of the

because of the blocking action of the diodes. This is true even if one input connection is

This section describes the proper connection of the -48VDC, 24VDC and

36-70VDC

terminals as negative (B-), positive(B+). The chassis “earth” or ground (GND) is a

C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN

36-70VDC GND

threaded post with a #6 nut. The Dual Source terminal block for the 24VDC and

absent, or even if it is connected with reverse polarity or shorted or grounded.

C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION

A+ AB- B+

its power from the DC source with the highest voltage at a given time.

input, i.e. the two DC power sources are not mixed together by the hub.

reversed while the Switch is operating from the other source.

correctly applied to either or both of the two inputs

absent or are both incorrectly connected.

Fig C5.0 is located on the right rear of

the unit and is equipped with five (5)

reverse model it is located on the left

identified as positive (A+), negative

screw-down lead posts. If it is the

rear. The primary terminals are

C5.0 INSTALLATION

(A-), and the secondary power

use.

Page 78 of the GarrettCom 6K32T user manual — C6.0 ORDERING INFORMATION
Page 78 · click to enlarge
Page 78

Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)

The 24VDC and 125VDC terminal block on Magnum 6K32T & 6K32TRC’s is

1. Minimum 18 AWG cable for connection to a Centralized DC power source. 2. Minimum 14 AWG cable for connection to earthing wiring. 3. Use only with Listed 10 A circuit breaker provided in building installation. 4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.
5. Fastening torque of the lugs on the terminal block: 9 inch pound max. 6. Centralized DC Power Source cable securement, use at least four Minimum 14 AWG cable ties to secure the cable to the rack at least 4 inches apart with the

Dual-Src-48V for the regular DS model with no ON-OFF switch

The connection procedure is straightforward. Simply connect the DC leads to

the Switch’s power terminals, positive (+) and negative (-) screws. Ensure that each lead

ExampleMagnum 6K32T & 6K32TRC-24VDC or Magnum 6K32T &

Similarly, order the “Dual –source 24VDC” or “Dual-source 125VDC” as a

Or Dual-Src125V-Switch for models with the ON-OFF switch

Operation of the Dual-Source Magnum 6Ks-48VDC, 24VDC and 125VDC

The following must be adhered to in order to conform to UL requirements:

To order the optional Dual-Source -48VDC power supply factory installed,

order “Dual-Src48V” as a separate line item following the product model.

or Dual-Src48V-SWITCH with the ON-OFF manual switch.

6K32TRC-125VDC Dual-Src24V for regular models with no ON-OFF switch

lead from 48V or –48V supply must be connected to the post labeled “+”.

Switch models are identical to that of the standard models.

first one located within 6 inches of the terminal block.

ExampleMagnum 6K32T & 6K32TRC-48VDC

similar to that described in the –48VDC information above.

separate line item following the product model.

C6.0 ORDERING INFORMATION

C7.0 OPERATION

C5.1 UL Requirements

is securely tightened.

Ask about the GarrettCom 6K32T

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom 6K32T

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom 6K32T manual PDF

78 pages·1.3 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…