EN
GarrettCom logo
Official user manual

GarrettCom 6K25e

69 pages·1.3 MB·Switch·PDF·ENDEFRITNLJA
GarrettCom 6K25e
Table of Contents 80 sections Gigabit Fiber Switch · Installation and User Guide · Magnum 6K25e · Hardware · … ShowHide
Gigabit Fiber Switchp.1Installation and User Guidep.1Magnum 6K25ep.1Hardwarep.1Managed Fiber Switchp.2Magnum ™ 6K25ep.2email [email protected]p.3Phone (510) 438-9071p.35.2.11 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX) .............52p.55.2.13a GBIC-LXSC & ZXSC Gigabit fiber (1000Mb), sm SC.........54p.56.3 Return Material Authorization (RMA) Procedure..............................56p.56.4 Shipping and Packaging Information.................................................57p.5APPENDIX A: WARRANTY INFORMATION .........................................57p.5APPENDIX B : INTERNAL DC POWER SUPPLY OPTIONS.................58p.5APPENDIX C: INTERNAL DC DUAL-SOURCE POWER OPTION ......60p.5Revisionsp.5Oct., 07p.6INDUSTRIAL NETWORKING PRODUCTSp.6"DESIGNED AND MANUFACTURED IN THE USA"p.6The Magnum Linep.6OVERVIEWp.61.1 Technical Specificationsp.71.0 SPECIFICATIONSp.7Alarm Contact (Optional)p.9Magnum Managed Fiber Switchp.10MODEL DESCRIPTIONp.102.2 Product Description - Magnum 6K25e Managed Fiber Switchp.132.1 Inspecting the Package and Productp.132.0 Introductionp.132.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb fiberp.152.2.1 Magnum 6K25e and 6K25eR chassisp.15ACTp.15F/Hp.15F/H LK LK LK LKp.152 4 6 8 LK LK LK LKp.15F/H ACTp.1610/100 LKp.162 4 6 8 F/ H ACTp.162.2.3 Eight-Port Copper Module, 6K8-RJ45p.1610/10 LK/AC 1p.173 F/H POEp.1710/10 LK/ACp.174 FULL/HALFp.172 4 6 F/ H POEp.176KP8-45RJp.17LINK LK / ACT 2p.17PoEp.172.2.6 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45 and 2@100Mbp.18fiber 4@RJ-45 + 2@ 100Mb ST or SCp.186KP8 -45RJp.182.2.7 Four-Port 10 Mb mm Fiber ST Modulesp.19TX RX LKp.19LKp.192 6 TX RX TX LK RX LKp.192 6 Tp.19F/ ACTp.2010/100 Lp.20F/p.202.2.8 Gigabit (1000Mbps) port modulesp.20TX LK RXp.20TX RX Lp.202.2.9 Packet Prioritization, 802.1p QOSp.212.2.10 Frame Buffering and Flow Controlp.212.2.11 Managed Network Software (MNS-6K ) for Magnum 6K25e-Seriesp.22Datap.25Internetp.25100Mbps Full duplex Fiber forp.251000Mb Data Mining Serversp.2510/100 LK 2 4 6 F/ H ACp.25UPLINKp.251 3 5 10/100 LKp.25PWRBRp.25LK/RX PORTp.25COL 10p.25COL 100p.252.4 Applicationsp.25GARRETTp.25100Mb Serversp.25LK/ACTp.26LK/ ACTp.26
Page 1 of the GarrettCom 6K25e user manual — Gigabit Fiber Switch
Page 1 · click to enlarge
Page 1
GarrettCom 6K25e — Gigabit Fiber Switch diagram (page 1)
Fig. 1 · Gigabit Fiber Switch

Gigabit Fiber Switch

Installation and User Guide

Magnum 6K25e

Hardware

Page 2 of the GarrettCom 6K25e user manual — Hardware
Page 2 · click to enlarge
Page 2

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is

shall render all warranties null and void. If problems are experienced

user serviceable parts. Attempted service by unauthorized personnel

of this publication may be reproduced without prior written permission from

Magnum Gigabit Fiber Switch Installation and User Guide (10/07)

with Magnum 6K25e Switch products, consult Section 6,

Copyright © 2007 GarrettCom, Inc. All rights reserved. No part

Installation and User Guide

Managed Fiber Switch

UL is a registered trademark of Underwriters Laboratories

Magnum ™ 6K25e

Part #84-00163Z (Rev. A)

Hardware

NEBS is a trademark of Telcordia Technologies

Troubleshooting, of this User Guide.

Ethernet is a trademark of Xerox Corporation

a registered trademark of GarrettCom, Inc.

Printed in the United States of America.

GarrettCom, Inc.

Trademarks

Page 3 of the GarrettCom 6K25e user manual — Phone (510) 438-9071
Page 3 · click to enlarge
Page 3

This equipment generates, uses and can radiate frequency energy and if

not installed and used properly, that is in strict accordance with the manufacturer's

instructions, may cause interference to radio communication. It has been tested

and found to comply with the limits for a Class A computing device in accordance

with the specifications in Subpart J of Part 15 of FCC rules, which are designed to

provide reasonable protection against such interference when operated in a

commercial environment. Operation of this equipment in a residential area is

likely to cause interference, in which case the user at his own expense will be

Cet appareil respecte toutes les exigences du Réglement sur le matériel du

Please use the mailing address, phone and fax numbers and email address listed

required to take whatever measures may be required to correct the interference.

Magnum Gigabit Fiber Switch Installation and User Guide (10/07)

This Class A digital apparatus meets all requirements of the Canadian

Websitehttp://www.GarrettCom.com

Radio Frequency Interference Statement

email [email protected]

below: GarrettCom, Inc.

47823 Westinghouse Dr. Fremont, CA 94539-7437

Phone (510) 438-9071

Interference-Causing Equipment Regulations.

Canada. Cet appareil est Classe A..

Show 4 more labels / short text on this page
Federal Communications Commission · Fax (510) 438-9072 · Canadian Emission · Contacting GarrettCom, Inc
Page 4 of the GarrettCom 6K25e user manual — email support@garrettcom.com
Page 4 · click to enlarge
Page 4
Page 4 of the GarrettCom 6K25e user manual — email support@garrettcom.com
Page 5 of the GarrettCom 6K25e user manual — Revisions
Page 5 · click to enlarge
Page 5

5.0 6K25E MANAGED FIBER SWITCH PORT MODULES 42 5.1 Inspecting the Package and Product 43

5.2 6KPM Module Description 43 5.2.1 6KP6-RJMST, multi-mode FX-ST “twist lock” Module 44 5.2.1a 6KP6-RJ10ST FX-ST “twist lock” Combo Module 44 5.2.1b 6KP4-F10ST, “twist lock” Module 44 5.2.1c 6KP4-FLSTFX, multi-mode FX-ST “twist lock” Module 45 5.2.2. 6KP6-RJMSC multi-mode FX-SC “snap-in” Fiber connector 46 5.2.3 6KP6-RJSSC single-mode FX-SC-type, “snap-in” connector 46 5.2.4 6KP6-RJSSCL single-modeFX-SC-type, “snap-in” connector 47 5.2.4a 6KP6-RJ10ST multi-modeFL-ST-type, “twist-lock” connector 47 5.2.5 6KP8-MTRJSmall-Form-factor 48 5.2.5a 6KP6-MT10ST FX , MTRJ Small-Form-Factor ST-Fiber port 48 5.2.6 6KP8-45MTmulti-mode FX MTRJ Small-Form-Factor 49 5.2.7 6KP8-MLC multi-mode LC connector Small-Form Factor 49 5.2.8 6KP8-45LC, Combo multi-mode -LC small-formfactor 50 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port 50 5.2.10 New PoE(Power Inside), model PI6KP8-45RJ (MDIX) 51

5.2.11 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX) 52

5.2.12 6KP8-45-2MT, multi-mode FX , MTRJ Small-Form-Factor 53 5.2.12a 6KP8-45-2LCsingle-mode FX , LC Small-Form-Factor 53 5.2.13 GBIC-SXSC Gigabit fiber(1000Mb), mm SC Connector 54

5.2.13a GBIC-LXSC & ZXSC Gigabit fiber (1000Mb), sm SC 54

5.2.14 6KM-BLNK ...............................................................................55 6.0 TROUBLESHOOTING.......................................................................55

6.1 Before Calling for Assistance.............................................................55

6.2 When Calling for Assistance..............................................................56

6.3 Return Material Authorization (RMA) Procedure..............................56

6.4 Shipping and Packaging Information.................................................57

APPENDIX A: WARRANTY INFORMATION .........................................57

APPENDIX B : INTERNAL DC POWER SUPPLY OPTIONS.................58

APPENDIX C: INTERNAL DC DUAL-SOURCE POWER OPTION ......60

Magnum Gigabit Fiber Switch Installation and User Guide (10/07)

Rev A 10/07 : This rev. is the initial release of the 6K25e manual.

Revisions

Page 6 of the GarrettCom 6K25e user manual — OVERVIEW
Page 6 · click to enlarge
Page 6

GarrettCom, Inc. offers the premium-quality Magnum™ line of

INDUSTRIAL conectivity products with industry-standard functionality and

built-in fiber configurability. Magnum products are designed for use in

demanding Industrial Grade, Carrier Class, POWER UTILITY and OEM

4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto-negotiating

Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed and mixed-media

mP62 and P62F “Outdoor” Ethernet SwitchES, for temperature uncontrolled locations, 6 10/100

Personal Hubs, 10Mb series 8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-

6K-Series Managed Field Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports, mix-and

Oct., 07

Media Converters, 10Mb and 100Mb series, All media combinations, incl. fiber ST, SC, mm.,

Personal Hubs, 100Mb or 10/100Mb 8-port, with 2 switched ports (1 fiber built in)

INDUSTRIAL NETWORKING PRODUCTS

"DESIGNED AND MANUFACTURED IN THE USA"

The Magnum Line

applications where reliability is a primary consideration.

Stackable Concentrators, SNMP optional, 13-Ports

OVERVIEW

Dual Speed 8-port and 16-port, 10/100 auto-sensing HUBS

Repeater Port Modules (RPMs), 6 types for Ethernet media

Mixed-Media Fiber Hub, 16-port, 10/100 auto-sensing

The “X-line” of configurable MiXed Media products:

DX-Series Serial Device Routers, Ethernet and Serial

port and 4 or 5-Port Personal Hubs, w/ man. up-link sw.

match. Features SFF fiber and DC power in 1U units.

and 2 100Mb fiber ports, can be connected in strings

8 port dual-speed, Auto-negotiable with fiber option

Mini-Concentrators, 7 Ports, Repeaters, 2-Ports

COAX Transceivers, 10Mb series

types, full switching performance.

Personal Switches, 10/100Mb

full switching performance.

single mode

Page 7 of the GarrettCom 6K25e user manual — 1.0 SPECIFICATIONS
Page 7 · click to enlarge
Page 7
Switching Processing TypeStore and Forward with IEEE 802.3x full-

100BASE-FX, full-duplex, single-mode - 20.0 km (66K25e ft)

100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft)

Unshielded twisted pair - 100 m (328 ft)

10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)

10BASE-FL single-mode fiber optic - 10 km (32,810 ft)

10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)

100BASE-TX (CAT 5 UTP) - 100 m (328 ft)

100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft)

1000BASE-T (CAT5E or higher is recommended) - 100 m (328 ft) 1000BASE-SX, full-duplex, multi-mode(62.5µm cable) - 220m 1000BASE-SX, full-duplex, multi-mode(50µm cable) - 550m 1000BASE-LX, full-duplex, single-mode(62.5µm cable) -5Km

Packet buffer size240KB for 10/100 and 120KB for 1000Mb

100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft)

100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)

Shielded twisted pair - 150 m (492 ft)

Shielded twisted pair - 150 m (492 ft)

Address Table Capacity4K node, self-learning with address aging

15 µs + packet time (10 to 10 Mbps, and 10 to 100Mbps)

IEEE 802.3z1000BASE-X Ethernet(Auto-negotiation)

Maximum Standard Gigabit Ethernet Segment Lengths:

Maximum Standard Fast Ethernet Segment Lengths:

Data Rate10Mbps,100Mbps and 1000Mbps

Network Standards and Compliance, hardware

Ethernet V1.0/V2.0 IEEE 802.310BASE-T,

Maximum 10 Mbps Ethernet Segment Lengths

duplex flow -control, non-blocking

Latency5 µ s + packet time (100 to 100Mbps)
IEEE 802.1wRapid Spanning tree protocol
IEEE 802.3u100Base-TX, 100BASE-FX
IEEE 802.3ab1000BASE-X Ethernet
Gigabit Ethernet1, 488,000 pps
IEEE 802.1dSpanning tree protocol

Filtering / Forwarding Rate:

Fast Ethernet148,800 pps
IEEE 802.1pPriority protocol
IEEE 802.1qVLAN Tagging
IEEE 802.3xFlow Control

1.1 Technical Specifications

Ethernet:14,880 pps

1.0 SPECIFICATIONS

Performance

Page 8 of the GarrettCom 6K25e user manual — 1.1 Technical Specifications
Page 8 · click to enlarge
Page 8

DB-9 for RS-232 “ null-modem “ cable (sometimes called an Xmodem cable)

Fiber Port, ST-type (twist-lock):Fiber multi-mode, 10Mb 10BASE-FL

Fiber Port, MTRJ-type (plug-in):SFF Fiber multi-mode100BASE-FX

Fiber Port, ST-type (twist-lock)Fiber optic m.-mode, 100BASE-FX

Fiber Port, SC-type (snap-in):Fiber optic multi-mode, 100BASE-FX

EnclosureRugged High strength metal. Suitable for stand-alone

with adjacent manual ON-OFF switch (on AC models only)

Fiber Port, SC-typeFiber optic single-mode, 100BASE-FX

Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX

AC Power ConnectorIEC-type, male recessed at rear of chassis,
IEC 60068 “Type Test” rating-40 ° to 185 ° F (-40 ° to 85 ° C)
Ambient Relative Humidity5% to 95% (non-condensing)
Power Consumptionsame as for AC models, see above

UL 60950 “Component Parts” temp. rating: 130° F (55°C)

-48VDC Power Input Voltage-36 to -70 VDC
125VDC Power Input Voltage88 to 300VDC Std. Terminal Block : “ -, GND, + ”

60 watts max (for a fully loaded fiber model) 35 watts for a fully-loaded copper only model

24VDC Power Input Voltage20 to 40 VDC
LKSteady ON when media link is operational
Dimensions1.70in. H x 17.0in. W x 9.0in. D

4.32cm H x 43.2cm W x 22.9cm D Cooling method: Fan cooled, @ 3@ 7 cfm ea.

Fiber Multi-mode connector types supported:

Fiber Port, 1000BASE-FX, GBIC modules

Fiber Port, 1000BASE-FX, GBIC modules

Altitude-200 to 13,000 ft. (-60 to 4000m)
Conformal Coating optionRequest quote
Input Voltage100 to 240 VAC (auto-ranging)

OFF = Half-Duplex Mode

Input Frequency47 to 63 Hz (auto-ranging)
FDX/HDXON = Full-Duplex Mode
ACTON with receiver port activity
Storage-40 ° to 185 ° F (-40 ° to 85 ° C)

Fiber Single-mode connector types:

Power Consumption55 watts typical
100/10ON = 100Mbps speed OFF = 10 Mbps

DC Power Supply (Options)

LEDsPer Port
Show 5 more labels / short text on this page
or rack-mounting · Management Console connector · Operating Environment · Power Supply (Internal) · Packaging
Page 9 of the GarrettCom 6K25e user manual — Alarm Contact (Optional)
Page 9 · click to enlarge
Page 9

are SPST NC Form-C relays, and an open condition indicates abnormal status. The

Dual Source options (for continuity of operation when either of the DC input sources

Alarm Contact option is offered as a configuration option. The two alarm contacts

For DC internal power supplies at –48VDC, 24VDC and 125VDC, including

The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45

ports., and eliminate the use of cross-over cable between the devices. Also port-

specific user settings (such as FDX or HDX, copper 10/100 speed) can be fixed

Hardware Alarm monitors internal power on the main board, and the Software

See also Note for Power Substations in Section 3.2.4, 3.6.1, and 5.2.9

IEEE 1613 Class 2 Environmental Standard for Electric Power Substations

IEC 61850 EMC and Operating Conditions Class C for Power Substations

UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class A

WarrantyThree years, return to factory Made in USA

Alarm is activated by one or more user-selected software traps.

NEBS Level 3 and ETSI Certified for Carrier Central Offices

Email sales@GarrettCom.com for details.

NEBS Testing and CertificationNEBS certified

are interrupted), see Appendices B and C.

Per-port MDI or MDIX on RJ-45

Alarm Contact (Optional)

using software commands.

Agency Approvals

Page 10 of the GarrettCom 6K25e user manual — MODEL DESCRIPTION
Page 10 · click to enlarge
Page 10

play switching services, front-mounted LEDs, internal auto-ranging AC power supply, 19"

Magnum 6K25eR“Reverse” model, same as Model 6K25e except the user ports and

the power input connectors are in the rear. Two sets of LEDs (both rear and front) provide

address table, large 240KB packet buffers for 10/100 and 120KB for 1000Mb. Plug-and-

Each Magnum 6K25e and 6K25eR base unit has four port module slots. The first

6KP8-45-2MT “6+2” module, w/six RJ-45 ports and two 2km mm MTRJ connectors

6KP8-45-2SLC “6+2” module, w/six RJ-45 ports and two 100Mb 15km sgl. mode FX LC connectors

port connector types, 25 total ports max. Wire speed filtering and forwarding across all

rack-mounting brackets. For licensed managed networks software, see MNS materials.

6KP4-FXST “2+2” 100Mb Fiber module, w/ four 100Mb 2km FX ST connectors

6KP8-45LC “4+4” module, w/four RJ-45 ports and four 2km mm LC connectors

May be configured with a selection of 10/100/1000 6K25e fiber and copper

6KP4-FLSTFX “2+2” ST Fiber module, w/ two 100Mb & two 10Mb ports, 2km 6KP8-45MT “4+4” module, w/four RJ-45 ports and four 2km mm FX MT-RJ’s

ports, 802.3x flow control, 802.1p priority packet processing, self-learning 4K-node

Magnum 6K25eR-125VDCSame as 6K25eR except the power input is 125VDC

three (A,B,C) may be one of the modules below, one (slot D) may only be a Gigabit

6KP4-F10ST “2+2” 10Mb Fiber module, w/ four 10Mb 2km FL ST connectors

6KP6-RJSSC “4+2” module, w/four RJ-45 ports and two 20km Sgl.m FX SC’s

6KP6-RJSSCL “4+2” module, w/four RJ-45 ports and two 40km Sgl.m FX SC’s

6KP6-MT10ST “4+2” module, w/four MTRJ ports and two 10Mb 2km FL ST’s 6KP6-RJ10ST “4+2” module, w/four RJ-45 ports and two 10Mb 2km FL ST ‘s

Magnum 6K25eR-48VDCSame as 6K25eR except the power input is –48VDC
Magnum 6K25e-125VDCSame as 6K25e except the power input is 125VDC
Magnum 6K25e-48VDCSame as 6K25e except the power input is –48VDC
Magnum 6K25eR-24VDCSame as 6K25eR except the power input is 24VDC

6KP8-MTRJ SFF Fiber module, w/eight 100Mb mm FX MT-RJ connectors

6KP8-SLC SFF Fiber module, w/eight 100Mbps sgl-m FX LC connectors

6KP8-RJ45 TP Module, w/eight 10/100Mbps auto-negotiating RJ-45 ports

6KP6-RJMST “4+2” module, w/four RJ-45 ports and two 2km mm FX SC’s

6KP6-RJMSC “4+2” module, w/four RJ-45 ports and two 2km mm FX ST‘s

Magnum 6K25e-24VDCSame as 6K25e except the power input is 24VDC

6KP8-MLC SFF Fiber module, w/eight 100Mbps mm FX LC connectors

Magnum Managed Fiber Switch

Magnum 6K25e Magnum 6K25e Managed Fiber Switch, base unit.

module. Select up to four port modules per base unit.

duplicate status data for viewing from either side.

MODEL DESCRIPTION

1.2 Ordering Information

Magnum 6K25e Port Modules

Configuration Options:

Page 11 of the GarrettCom 6K25e user manual — Magnum Managed Fiber Switch
Page 11 · click to enlarge
Page 11

GBIC-SXSC GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-SX

GBIC-LXSC40 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-ZX

GBIC-LXSC70 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-ZX

GBPM-COTX One slot Gigabit 6K module for 6K25e Switches, uses one 6K25e slot

New P6KP8-RJ45 8 port PoE module for 6ks with 48vdc PS, w/eight PoE power source

New P6KP8-45MLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP8-45-2MT “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

GBIC-LXSC10 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-

GBIC-LXSC25 GBIC transceiver module for use in GBPM-xOTX, one 1000BASE-

CONSOLE CBL Industry standard serial cable, DB-9 connectors for RS-232 “ null-

CONSOLE USB Console attachment cable, serial to USB, cable with one DB9 for the

New P6KP8-45MT “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP8-45SLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX MTRJ connectors

modem “ connection (sometimes called an Xmodem cable), used to connect a PC or a

10/100 auto-negotiating auto cross RJ-45 ports. New P6KP8-45RJ “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

and provides one GBIC open transceiver port for a user-selectable GBIC transceiver

6K PoE Modules with 48VDC Pass-Through Configuration options: only one A, B or C module slot of 6K-Series switch with

GBIC transceiver module for use in GBPM-COTX, one LX port with mm SC fiber

GBIC-TP GBIC transceiver module for use in GBPM-xOTX, one 802.3ab

1000BASE-T port, RJ-45 connector 6KM-BLNK Blank cover for one 6K25e (A,B,or C) module slot opening in a

managed Switch and a USB interface for the USB connector to a PC.

48VDC power input may be configured with a PoE Modules

LX/LH port with 1310nm sgl. mode SC(10km) fiber connector

LX/LH port with 1310nm sgl. mode SC(25km) fiber connector

source and four 10/100 auto-negotiating auto cross RJ-45 ports

port with 1550nm, sgl. mode SC(40km) fiber connector

port with 1550nm, sgl. mode SC(70km) fiber connector

source and four 100 Mb 2km mm FX MTRJ connectors

For Gigabit module configuration options

source and four 100 Mb 2km mm FX LC connectors

source and four 100 Mb 15km sm FX LC connectors

character terminal to the Management port.

Magnum 6K25e or 6K25eR chassis

port with mm SC fiber connector

connector · module

Page 12 of the GarrettCom 6K25e user manual — Magnum Managed Fiber Switch
Page 12 · click to enlarge
Page 12

New PI6KP6-RJSSCL “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four POE power

New P6KP8-452SLC “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJSSCL “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJ10ST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New 6K125VDC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a

New PI6KP8-45MLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-45SLC “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-45-2MT “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-452SLC “6+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP6-RJMST “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP6-RJMSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

New P6KP6-RJSSC “4+2” port PoE module for 6ks with 48vdc PS, w/four PoE power

48VDC power input may be configured with a PoE Modules New 6KAC-PoE-PS Power supply for PoE to 4 ports, 60 watts, mounts inside of a full-

New PI6KP8-45RJ “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

New PI6KP8-45MT “4+4” port PoE module for 6ks with 48vdc PS, w/four PoE power

source and two normal RJ-45 10/100 ports +two100 Mb 2km mm FX MTRJ connectors

Configuration optionsonly one A, B or C module slot of 6K-Series switch with

6K PoE Modules with 48VDC Power Inside NOTE: For configuring in 6K Switches having AC /125VDC power input

GarrettCom, Inc. reserves the right to change specifications, performance

source and four 10/100 auto-negotiating auto cross RJ-45 ports

full-width rack-mount 6K switch with 125VDC power input.

characteristics and/or model offerings without notice.

source and four 100 Mb 2km mm FX MTRJ connectors

source and four 100 Mb 15km Sm FX LC connectors

source and two 100 Mb 2km mm FX ST connectors

source and two 100 Mb 2km mm FX SC connectors

source and two 100 Mb 20km sm FX SC connectors

source and two 100 Mb 40km sm FX SC connectors

source and four 100 Mb 2km mm FX LC connectors

source and four 100 Mb 15km sm FX LC connectors

source and four 100 Mb 15km Sm FX LC connectors

source and two 100 Mb 2km mm FX ST connectors

source and two 100 Mb 2km mm FX SC connectors

source and two 100 Mb 20km sm FX SC connectors

source and two 100 Mb 40km sm FX SC connectors

width rack-mount 6K switch with AC power input.

source and two 10 Mb 2km sm FL ST connectors

source and two 10 Mb 2km sm FL ST connectors

Page 13 of the GarrettCom 6K25e user manual — 2.0 Introduction
Page 13 · click to enlarge
Page 13

In the event there are items missing or damaged, contact the party from whom

The Magnum Managed Fiber Switch boosts the performance of large Ethernet

LANs, typically serving as a “backbone” switch. It has the flexibility to handle a mix of

1U (1.70in. or 4.32cm) high. The “mixed-media” capability allows user selection of all

product; notify the carrier of any damage that you believe occurred during shipment or

delivery. Inspect the contents of this package for any signs of damage and ensure that

Remove the items from the shipping container. Be sure to keep the shipping

shipping container if possible. Refer to Section 6, Troubleshooting, for specific return

performance switching services for both “smooth” streaming and “bursty” data traffic.

configured as fiber ports, but still offers a space-saving rack-mount chassis that is only

with Gigabit ports. It also allows a mix of 10/100Mb RJ-45 (copper) ports and a fiber

Examine the shipping container for obvious damage prior to installing this

container should you need to re-ship the unit at a later date. To validate the product

both fiber and twisted-pair switched ports along with Gigabit backbone port options.

popular flavors of fiber port connectors and modes, including even 10Mb fiber along

you purchased the product. If the unit needs to be returned, please use the original

2.2 Product Description - Magnum 6K25e Managed Fiber Switch

warranty, please complete and return the enclosed Product Registration Card to

The Magnum 6K25e has up to 25 ports capacity, all of which may be

Industry-standard IEEE 802.1p QOS prioritization is included, providing high

(configured with user-selected port module options)

1 Magnum 6K25e Managed Fiber Switch, base unit

1 AC Power Cord (U.S. and other 115 VAC only)

1 Set of metal “Ears” for 19” rack mounting

1 Installation and User Guide (this manual)

2.1 Inspecting the Package and Product

1 Product Registration Card

This package should contain:

GarrettCom, Inc. as soon as possible.

the items listed below are included.

2.0 Introduction

procedures.

Page 14 of the GarrettCom 6K25e user manual — 2.2 Product Description - Magnum 6K25e Managed Fiber Switch
Page 14 · click to enlarge
Page 14

LEDs in the front and the power input and management console connector in the rear) or

accommodated include standard 19” RETMA, ETSI, and 23” Telco. Input power may be

Fiber Switches are easy to install and use. Addresses of attached nodes are automatically

performance plug-and-play hardware operation, 802.1p packet prioritization in hardware,

power –inside PoE modules and allows the users to select a wide option of combo PoE

modules to support 802.3af pd devices. See details in sec 5.2.10 and 5.2.11. The Power

wireless access points, IP phones) that comply with the IEEE 802.3af PoE standard. The

duty applications. The chassis mounting rack style may be “regular” (with the ports and

chassis unit (or may be changed in the field by trained technicians) to adapt the unit to

the user’s application and Ethernet cabling requirements. Even evolving mixed-media

The packaging and power-input options target the Magnum 6K25e at heavy-

“Reverse” (with the ports and LEDs and the power-input and the management console

learned, maintained and aged out, adapting the switching services to network changes.

and industry-standard managed networks software functionality, all in convenient 1U

Gigabit port in the same unit. This flexibility is achieved via a family of 6K25e port

modules for copper and fiber-built-in (emphasizing Small Form Factor fiber for high

module selections using GBICs. These modules can be factory configured in a base

The 6K25e managed switches also provides PoE option via Power-pass-through and

Sourcing Equipment (PSE), and are fully compatible with Powered Devices (PD)(e.g

PoE switch ports have an auto-sensing algorithm, so that they provide power only to

802.3af, PoE end devices. PoE is managed by a multi-stage handshake to protect

Designed for use in network traffic centers, the Magnum 6K25e Managed

fiber port density), 6-port modules for fiber and RJ-45 combinations, and 1Gb port

requirements for 10Mb and 100Mb fiber and copper as well as Gigabit ports can be

discontinue supplying power when the PoE powered devices are disconnected, and

LEDs provide status information on each port. The Magnum 6K25e provides high

support the 802.3af PoE PSE standard for over-current protection, under-current

equipment from damage and to manage power budgets.The PoE ports will

connector all in the rear and a duplicate set of LEDs in the front). Rack widths

AC, or –48VDC for Telco environments, or 24VDC for Industrial applications.

handled by the Magnum 6K25e product.

detection, and fault protection.

rack-mount packages.

Page 15 of the GarrettCom 6K25e user manual — F/H LK LK LK LK
Page 15 · click to enlarge
Page 15

eight-port slots (A, B, and C) and one Gb-only slot (D) for configuration flexibility. Slots

types and combinations of types, typically eight ports per module, but sometimes 6 or 4

serve a large variety of applications, especially using fiber media. The Magnum 6K25e

Status LEDs are part of each port module and are viewable when connecting

“Reverse” rack-mount models, there is a duplicate set of LEDs on the other (front) side

2.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb fiber

6K8-MTRJ (to the left) and

port modules are normally factory installed, but may be changed or added in the field.

GarrettCom 6K25e — 2.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb fiber diagram (page 15)
Fig. 2 · 2.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-ML…

A, B and C may be configured with any of a large selection of fiber and copper port

ports or even one Gb port. Slot D may be configured with a Gb module that accepts

GBICs. The port types configurable using the 4 slots allows the 6K25e to efficiently

for normal status viewing from that direction. Of course, with management, the port

The Magnum 6K25e is a 19” rack-mountable Ethernet Switch with three

6K8-MLC or -SLC (below)

the Ethernet media. A “regular” rack-mount 6K25e is shown in Figure 2.2.1a. On

Figure 2.2.1a“Regular” 6K25e front view, configured for 24 +1 Gb ports

Fig.2.2.2 :

2.2.1 Magnum 6K25e and 6K25eR chassis

ACT

F/H

ACT

F/H

ACT

F/H

ACT

F/H

status data is also available in software.

1 3 5 7

F/H LK

2 4 6 8 LK LK LK LK

ACT

ACT

F/H

ACT

F/H

ACT

F/H

SFF Fiber Port · Modules, · (See Section 5)

Page 16 of the GarrettCom 6K25e user manual — 2.2.3 Eight-Port Copper Module, 6K8-RJ45
Page 16 · click to enlarge
Page 16

speed (100Mb), mode, and connector type. Models are available with Small Form Factor

(SFF) are multi-mode MT-RJ or LC-

default) to operate in full-duplex mode for best fiber distance and performance. Using the

set-up of the software (See Magnum 6K25e MNS Software Manual) for the flexibility to

F/H ACT

(See Section 4.3 for auto-negotiation and MDIX details). The auto-crossover feature will

6K25e’s MNS software, the user may select full- or half-duplex mode per-port through

There are three LED’s per fiber port. The Link (LK) LED indicates “ready for

Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK)

10/100 LK

2 4 6 8 F/ H ACT

10/100 LK

crossover(MDIX) for operation at 10 or 100Mb speed in full- or half-duplex mode, i.e.,

each independently selects a mode and speed to match the device at the other end of the

In an eight-port SFF fiber port module, all of the fiber ports are of the same

type connectors, and single-mode

The 100Mb fiber eight-

6K25e’s normally are set (factory

operation” on that port when lit, the F/H LED indicates operation in full-duplex mode

indicator for that port must be ON (indicating there is a powered-up device at the other

port modules for the Magnum

when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving

end of the cable) in order for a LK LED to provide valid indications of operating

automatically determine the other side of connection to make the connection, and

1 3 5 7

LC-type connectors.

adapt to any FDX or HDX type of Fast Ethernet devices).

2.2.3 Eight-Port Copper Module, 6K8-RJ45

GarrettCom 6K25e — 2.2.3 Eight-Port Copper Module, 6K8-RJ45 diagram (page 16)
Fig. 3 · 2.2.3 Eight-Port Copper Module, 6K8-RJ45

ports. The 10/100Mb switched

way auto-negotiating, and auto-

Copper port module, model

ports normally (as a default

setting) are independently N-

conditions on that port.

twisted pair cable.

The 6K25e-Series’s 8-port · 6K8-RJ45, provides eight · 10/100Mb switched RJ-45

Page 17 of the GarrettCom 6K25e user manual — 6KP8-45RJ
Page 17 · click to enlarge
Page 17

port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that port

into an RJ-45 port and the Link (LK) indicator for that port must be ON (indicating there

802.3af PoE pd devices. The 4-RJ45 POE

On the model 6K8-RJ45 module, there are four LEDs for each port, two in the

connector and two separate. The LK (Link) LED indicates “ready for operation” on that

Using the 6K8-Series (MNS-6K) management software, the user may disable

auto-negotiation and fix the desired operation of each RJ-45 port. User may select 10Mb

The New PoE RJ-45 ports act similar to regular RJ-45 ports, except they have

standard. Only 4 x RJ-

mounted 6K-unit. The

option to support four

when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10 Mb

GarrettCom 6K25e — 10/10 LK/AC 1 diagram (page 17)
Fig. 4

is a powered-up device at the other end of the cable) in order for a LK LED to provide

2.2.4 New PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-port

or 100Mb speed and full- or half-duplex mode per-port as per user requirement. (See

IEEE802.3af PoE

45 (10/100) ports maxm. support

option in one rack

module are also available with mix –n-match with fiber modules. Please check the

capability of providing power on each port to power up the PD devices, per the

10/10 LK/AC 1

3 F/H POE

valid indications of operating conditions on that port.

Magnum MNS-6K Software Manual for details info.).

2 1 3 5

eliminate the need of cross-over cable.

10/10 LK/AC

4 FULL/HALF

2 4 6 F/ H POE

speed when OFF (when auto-

operation and OFF to indicate

pair cable must be connected

8 Port@ 10/100Mb Copper ports

negotiation is not disabled).

The FDX/HDX LED is ON

half-duplex mode. A twisted

6KP8-45RJ

LINK LK / ACT 2

PoE

Show 8 more labels / short text on this page
POE(Power Inside) · power inside PoE · equipped with the · necesasary power · option is factory · configured and · 10/10 · to indicate full-duplex
Page 18 of the GarrettCom 6K25e user manual — 6KP8 -45RJ
Page 18 · click to enlarge
Page 18

except they have capability of providing power on each port to power up the PD devices,

standard. The Power Pass-

totally dependent upon the

Maxm. one PoE modules

A, B or C slot of any 6K s

The PoE modules are also

The four RJ-45 ports operate just like the 8-port copper module with auto-cross

PoE LED is ON when connected properly to a 803.af compliant PD device on that port.

When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

The PoE (Power-pass-through) RJ-45 ports act similar to regular RJ-45 ports,

per the IEEE802.3af PoE

through PoE modules are

power supply to support

ports. Each port requires

atleast 15watts to power

can be configured in the

with -48vdc power input.

available with mix –n-match with fiber modules. Please check the ordering information

PoE LED is ON when connected properly to a 803.af compliant PD device on that port.

When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

2.2.6 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45 and 2@100Mb

four 10/100 switched RJ-45 copper ports and two 100Mb switched multi-mode fiber ST,

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

2.2.5 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8- port

up the PoE PD devices.

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

The combo six-port modules are combinations of copper and fiber media, available as

SC or single mode SC or Long Reach SC ports. For ports numbering, ports 1,3,5,7 are

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to

ordering information Sec.1.2. for all the various PI6K PoE modules option.

copper, ports 2 and 6 are fiber, ports 4 and 8 are not present.

10/10 LK/AC 1

3 F/H POE

that is marked as LINK/ACT, as shown in the diagram.

that is marked as LINK/ACT, as shown in the diagram.

2 1 3 5

Sec.1.2 for all the various P6K PoE modules option.

fiber 4@RJ-45 + 2@ 100Mb ST or SC

10/10 LK/AC

4 FULL/HALF

2 4 6 F/ H POE

traffic is not affected by PoE.

traffic is not affected by PoE.

8 Port@ 10/100Mb Copper ports

6KP8 -45RJ

LINK LK / ACT 2

Show 4 more labels / short text on this page
powerful -48VDC input · more RJ-45 (10/100) · 10/10 · PoE
Page 19 of the GarrettCom 6K25e user manual — ACT
Page 19 · click to enlarge
Page 19

On Magnum “4+2” Combo modules, there are four LED’s for each RJ-45 port,

which indicate status the same as described for the 6K8-RJ45 in Section 2.2.3 above. The

2@10Mb fiber mm ST ports, and with

4@ RJ45 10/100 copper and 2@10Mb

six-port modules are also available

copper and 2@10Mb fiber mm ST

and the RJ-45 half of the module is as described for those port types above. For detailed

(MDIX) feature to eliminate the use of cross-over cable, and the two fiber ports operate

at 100Mbps full-duplex (default). User mode control per port through the MNS software

fiber port’s LEDs indicate status the same way as described for the SFF fiber modules in

4@ MTRJ 100Mb mm SFF fiber and

4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber and the RJ-45 half of

with 4@ MTRJ 100Mb mm SFF

fiber and 2@10Mb fiber mm ST

ports, and with 4@ RJ45 10/100

The Magnum Combo six-

port modules are also available with

the module is as described for those port types above. For detailed information about

ports. The 4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber

information about 10Mb mm ST fiber half of the module, please check section 2.2.5.

The 4port @10Mb ST fiber modules behave the same as the 8@100Mb ST

Section 2.2.2 above. Color-coding on the panel of the module shows which LEDs

fiber mm ST ports. The

2.2.7 Four-Port 10 Mb mm Fiber ST Modules

10Mb mm ST fiber half of the module, see Section 2.2.5.

TX RX LK

R

GarrettCom 6K25e — TX RX LK diagram (page 19)
Fig. 5

LK

2 6 TX RX TX LK RX LK

GarrettCom 6K25e — LK diagram (page 19)
Fig. 6

1 3 5 7

2 6 T

ACT

F/H

ACT

F/H

TX RX LK

TX RX LK

belong to which port.

ACT

F/H

ACT

F/H

is also the same.

The Magnum Combo

Page 20 of the GarrettCom 6K25e user manual — ACT
Page 20 · click to enlarge
Page 20

1@ 1000Mb Fiber SC + 2@ 100Mb SC

G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber

The 6K25e Modules provide a GBIC opening for insertion of industry-standard

media converter or almost any other device with a 10Mb fiber Ethernet port. User mode

control per port through the MNS software is the same as the other 6K25e modules. The

The Magnum 6K25e offered a wide option Gigabit speed with multiple choice

for the modular slot. While up to two Gigabit modules (maxm.) can be configured in the

configuration. The Giga port has been offered

F/ ACT

module on the Gigabit -SX and Gigabit-LX 1@ 1000Mb Fiber SC + 4@10/ 100Mb

There are two LEDs mounted on each Gigabit port module. The Gigabit fiber

present, ports 3, 4. 7, 8 are not present. The default setup on the 10Mb fiber module is

half-duplex, which allows the Magnum 6K25e Switch to connect to any 10Mb hub or

fiber ports support fiber cabling distances according to the 10BASE-FL standard, i.e.,

modular slot. The Gigabit port option for the modular slot comes in couple of different

as single Gigabit module comes in flavor of

GBICs to provide Gigabit (Gb) media flexibility. GBIC models are available for both

multi-mode (550m) and single-mode (10, 25, 40, 70)km fiber options, and for Gigabit

10/100 L

port is by default configured at AUTO mode, and can be fix at 1000Mbps speed full-

fiber modules except for the 10Mb speed. For ports numbering, ports 1, 2, 5, 6 are

2km distance for multi-mode fiber. (Single-mode for up to 10Km distance may be

1 3 5 7

duplex mode at any times and has LEDs that indicate LK (Link status) and ACT

copper as well, with new models appearing often.

transceivers are compatible with the IEEE 802.3z Gigabit standards.

ports) as shown below .

TX RX LK

ACT

F/

2.2.8 Gigabit (1000Mbps) port modules

performance. The 1000Mbps SC fiber-optic

available as a special order configuration).

normally set (factory default) to operate at

The 1000Mb Gigabit fiber-port

(receiving activity) on that port when lit.

AUTO mode for best fiber distance and

TX LK RX

modules on the Magnum 6K25es are

ACT

F/

TX RX LK

TX RX L

ACT

ACT

F/

F/

Page 21 of the GarrettCom 6K25e user manual — 2.2.9 Packet Prioritization, 802.1p QOS
Page 21 · click to enlarge
Page 21

and fulfills its role in support of QOS, giving packet processing priority to priority tagged

CRC, i.e., are good packets. This eliminates the propagation of bad packets, enabling all

control sequence occurs in a small fraction of a second and is transparent to an observer.

users from datagram paths that go all across a network. As a LAN device, the Magnum

packets according to the 802.1p standard. In addition to hardware support for QOS, the

"express") impose minimal frame latency, they will also permit bad frames to propagate

out to the Ethernet segments connected. The "cut-through" technique permits collision

fragment frames (which are a result of late collisions) to be forwarded which add to the

network traffic. Since there is no way to filter frames with a bad CRC (the entire frame

collisions and bad packets are more likely when traffic is heavy, the result of store-and-

forward operation is that more bandwidth is available for good packets when the traffic

The Magnum 6K25e switching hardware supports the IEEE 802.1p standard

Magnum 6K25e’s are store-and-forward switches. Each frame (or packet) is

When the Magnum 6K25e Switch detects that its free buffer queue space is

control mechanism (when operating at half-duplex only). When the Switch detects that

Quality of Service means providing consistent predictable data delivery to

MNS software (R2) supports two priority queues that can be shared across the eight

levels of defined packet priorities for application-specific priority control by the user

technique ensures that all forwarded frames are of a valid length and have the correct

low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the

dropping packets. Then, normal packet buffering and processing resumes. This flow-

Another feature implemented in Magnum 6K25e Switches is a collision-based flow-

6K25e can do its part to prevent any QOS degradation while it is handling Ethernet

loaded into the Switch’s memory and inspected before forwarding can occur. This

must be present in order for CRC to be calculated), the result of indiscriminate cut-

through forwarding is greater traffic congestion, especially at peak activity. Since

While other switching technologies (such as "cut-through" or

devices sending packets to cause “flow control”. This tells the sending devices to

temporarily stop sending traffic, which allows a traffic catch-up to occur without

of the available bandwidth to be used for valid information.

2.2.9 Packet Prioritization, 802.1p QOS

2.2.10 Frame Buffering and Flow Control

through software configuration settings.

traffic through its ports and buffers.

load is greatest.

Page 22 of the GarrettCom 6K25e user manual — 2.2.11 Managed Network Software (MNS-6K ) for Magnum 6K25e-Series
Page 22 · click to enlarge
Page 22

2.2.11 Managed Network Software (MNS-6K ) for Magnum 6K25e-Series

version only, using any other MNS-6K version will not support the 6k25e hardware)

All MNS-6K software information, including new releases and upgrades related to MNS-

Magnum 6K25e’s come with Rel3.7 licensed MNS-6K software, which allows the user

to configure the Magnum 6K25e as a Managed Switch and implements security features

(NOTEMagnum 625e managed switch will work with Rel 3.7 firmware or higher

Software User guide in pdf format, a separate document normally accessible via your

For interactive training software which shows basic and advanced info about

the Magnum MNS-6K management software and for a useful tool for first time users,

its free buffer queue space is low, the Switch prevents more frames from entering by

forcing a collision signal on all receiving half-duplex ports in order to stop incoming

www.GarrettCom.com/techsupport/index.htm#software and look for the

For additional information about MNS-6K, see the Magnum MNS-6K

Alternatively, for the latest documentation and information, or needed

6K software, can be accessed and download from GarrettCom’s FTP site.

You may also email: info@GarrettCom.com for further information.

or FTP client program at ftp.GarrettCom.com using

visit Magnum MNS-6K Operator Training.

web-browser, at ftp://ftp.garrettcom.com/

GarrettCom’s MIBs for SNMP, visit

and other software enabled features.

passwordm6kuser
userm6kuser

Magnum MNS-6K info.

traffic.

Page 23 of the GarrettCom 6K25e user manual — 2.2.11 Managed Network Software (MNS-6K ) for Magnum 6K25e-Series
Page 23 · click to enlarge
Page 23

Magnum 6K25e Managed Fiber Switches are designed to naturally include fiber ports,

Release 3.7 (Fall ’07) includes SNMP Switch Management with secure access control,

The 1U Magnum 6K25e chassis has 4 slots for port configurations. Family of 4, 6 or 8

port modules allow the user to select the desired mix of port types & speeds. The port

The standard rack mounting provides Ethernet ports and status LEDs in front, service

applications, models with –48VDC or 24VDC or 125VDC are available. Dual Source

„ Heavy-duty design for Industrial Ethernet and extended temperature operation.

provides for this with heavy-duty components. The ambient temperature can be up to

RMON, CLI, Port Security; Port Mirroring; Port Settings Control; Telnet, TFTP, FTP

once) performance with standard Managed Networks Software (MNS-6K) included.

priority to priority tagged packets according to the IEEE 802.1p standard. For port-

and application-specific priorities, the QoS software may be configured by the user.

The 6K25e has been tested and certified for NEBS and ETSI. Request test reports.

support, Spanning Tree Protocol, RSTP, Web-based, multi-level QoS, Port- and tag-

They are typically used in LAN traffic centers with eight Gigabit ports or 16 to 24

100Mb ports and one or 2 Gigabit ports for backbone connections, where managed network services are desired.

„ Modular design for port flexibility, in a 1U space-saving rack-mount package

modules are normally factory installed and tested, but may be changed in the field.

Standard 19’ rack mount brackets are included, with ETSI and 23” Telco optional.

Standard AC power input is IEC plug, auto-ranging for worldwide use. For special

„ MNS-6K licensed Network Management Software included, S-Ring optional

Magnum 6K25e Switches provide non-blocking (all ports can run at full speed at

The Magnum 6K25e switching hardware supports QoS, giving packet processing

and support mixes of multi-mode and single-mode; 10 Mb, 100Mb and 1000Mb

„ Rack-mounting may be standard or “reverse”, 19 inch or ETSI or 23” Telco

„ Standard AC power input, -48VDC or 24VDC or 125VDC input is optional

based VLANs, GVRP, IGMP Snooping, SNMPc GUI support; Event Log; SNTP

connectors. RJ-45 10/100 ports can also be configured in the mix of port types.

connections (power input and management console) in the rear. “Reverse” rack

mounting provides status LEDs in front and all cabling connections in the rear.

Fiber ports take more power than copper ports, but the Magnum 6K25e design

speed; full-and half-duplex; classic Small Form Factor (SFF) and GBIC fiber

DC input can also be selected and configured on the DC power input models.

„ Switching services includes 802.1p QoS packet prioritization

„ Managed switching for high performance Ethernet LANs

55°C. „ NEBS and ETSI tested and certified

2.3 Features and Benefits

„ Features Fiber-Built-In

Page 24 of the GarrettCom 6K25e user manual — 2.2.11 Managed Network Software (MNS-6K ) for Magnum 6K25e-Series
Page 24 · click to enlarge
Page 24

cross-over cable. The Auto-MDIX capability allow the Magnum 6K25e to cascade any

Due to design constrains, Slot D will be populated With either Dual SFP Giga or Dual

The 6K25e managed switch must be loaded with Rel 3.7 or higher Firmware, in order

The RJ-45 modules are equipped with MDI/MDIX capability to eliminate the use of

The modular Gigabit fiber switch can be populated with maxm. Gigabit ports, where

client for time-of-day; BootP and DHCP client for IP configuring, and password

RJ-45 Gigabit, or combo of both. No GBIC module will be supported on Slot D.

Slot D must have either Dual SFP OR Dual copper or COMBO of the one each..

„ 6k25e hardware are compatible with Rel. 3.7 or higher MNS-6K firmware

to work efficiently. Any lower version might cause problem on hardware.

„ Maxm. 8 Gigabit ports can be populated on 6K25e managed switch

security. Supplied and updated via Internet and GCI FTP Server.

Hub, switches or media converters with normal straight cable.

„ SFP Gigabit module being supported on Slot D

„ RJ-45 ports are MDI/MDIX supported

Page 25 of the GarrettCom 6K25e user manual — UPLINK
Page 25 · click to enlarge
Page 25

Data

Internet

Data

Magnum 800E Workgroup Hub 100 GARRETT LINK RX LINK RX PWR COL 1 2 4 5 6 8

100Mbps Full duplex Fiber for

Magnum 6K25e Fiber Switches offer high performance and modularity. They

Switch port) in a LAN traffic center. The subnet connections may be via fiber or twisted

The entire network is sharing a higher bandwidth Gigabit-enabled data-mining server for

for multiple subnets inside the building. The entire spread network is managed to provide

another Bldg.

provide the flexibility of 100Mbps fiber and copper ports as well as Gigabit ports, with

industry-standard LAN management software. Magnum 6K25e Switches are easily used

6K25e Switches enables them to inter-connect a series of subnets (one subnet per 6K25e

Example 1. In a Telecommunications storage data application, a secure managed switch

Magnum 800E Workgroup Hub 100 GARRETT LINK RX LINK RX PWR COL 1 2 4 5 6 8

in a variety of applications including MANs (metropolitan area networks) client/server

computing, secure VLAN- performance upgrades to departmental networks, and LAN

subnets. The backbone consists of high speed LAN segments supported by 1000Mbps

full-duplex future-proof fiber media to provide secure long distance LAN connections.

the vital database located in a separate secured building. The copper ports are required

1000Mb Data Mining Servers

traffic centers require Gb backbone services. The performance characteristic of the

The mixed-media capability is ideal for upgrading existing Ethernet LAN

networks where existing cabling must be accommodated. The fiber-built-in media

capability is ideal for integrating future-proof fiber cabling into the LAN structure.

is required to provide an Ethernet backbone for a diversified network with multiple

easy, detectable, uninterrupted support through a viewable SNMP monitor.

pair cabling, 100Mbps or 10 Mbps speed, and full-or half-duplex mode.

10Mb Workgroup 100Mb Servers

1 2 3 4 5 6 7 8 9 10 11

12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11

Magnum DS8016 Stackable Hub

10/100 LK 2 4 6 F/ H AC

10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

UPLINK

1 3 5 10/100 LK

F/H ACT

12 13 14 15 16

Magnum DS8016 Stackable Hub

10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

UPLINK

PWRBR

LK/RX PORT

COL 10

COL 100

LK/RX PORT

10/100 LK 2 4 6 F/ H AC

Magnum 800E Workgroup Hub 100 GARRETT LINK RX LINK RX PWR COL 1 2 4 5 6 8

PWRBR

COL 10

COL 100

Magnum 800E Workgroup Hub 100 GARRETT LINK RX LINK RX PWR COL 1 2 4 5 6 8

1 3 5 10/100 LK

F/H ACT

Magnum 800E Workgroup Hub 100 GARRETT LINK RX LINK RX PWR COL 1 2 4 5 6 8

1 2 3 4 5 6 7 8 9 10 11

Magnum 6K32 1 3 5 10/100 LK

10/100 LK 2 4 6 F/ H AC

F/H ACT

12 13 14 15 16

Magnum DS8016 Stackable Hub

10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

UPLINK

1 2 3 4 5 6 7 8 9 10 11

LK/RX PORT

2.4 Applications

PWRBR

COL 10

COL 100

1 2 3 4 5 6 7 8 9 10 11

12 13 14 15 16

GARRETT

Magnum DS8016 Stackable Hub

10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

UPLINK

12 13 14 15 16

Magnum 800E Workgroup Hub 100 GARRETT LINK RX LINK RX PWR COL 1 2 4 5 6 8

Magnum DS8016 Stackable Hub

10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

UPLINK

100Mb Servers

COL 10

COL 100

LK/RX PORT

LK/RX PORT

PWRBR

COL 10

COL 100

Data

PWRBR

Data

Data

Show 19 more labels / short text on this page
Router · Data · Data · and Workstations · 100Mb Servers · Data · Data · Data · Data · and Workstations · Magnum QS5116 · Magnum QS5116 PW · Fiber Switch · Managed Fiber · Switch · Data · and Workstations · 100Mb Servers · and Workstations
Page 26 of the GarrettCom 6K25e user manual — F/H
Page 26 · click to enlarge
Page 26

choices of modules to support future expansion as the network evolves. The dual Gigabit

network requirements by providing copper/fiber media along with the higher bandwidth

GarrettCom 6K25e — LK/ACT diagram (page 26)
Fig. 7

VLAN, Port security, 802.1X, and other security features to provide a secure and stable

The 6K25e Managed Switch with NEBS Level 3 compliance and management

advantage by fulfilling the present requirements as well as benefiting from the multiple

Example 2In a “ (video+data)” application where a network being designed to catered
GarrettCom 6K25e — LK/ACT diagram (page 26)
Fig. 8

support of 10/100 and 1000Mb. The user can utilize the SNMP feature equipped with

port option in the modular slot boosts the bandwidth for high speed to support the peak

the need of multicast streaming and broadcast traffic of higher bandwidth to provide a

The Magnum 625e Managed Switch equipped with copper and optional dual Gigabit

The Magnum 6K25e with four slots might filled with 8

requirements. The user-configurable Magnum 6K25e provides an extra boost to the

flexibility allows the user more than one configuration alternative. The user has an

requirement efficiently. The New IGMP L2-Mode feature on Magnum 6K25e and

loaded with management capability and secure web feature fulill this requirement

fiber ports on modular slots provide an economical and seamless solution to the

Gigaport module and a robust management firmware with MNS-6K qualify this

LK/ACT

LK/ACT

video conferencing and video in demand channel option to the user.

LK/ACT

LK/ACT

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

16 14 12 10 8 6 4 2

6K32TRC with IGMP-L2 mode

1 8 6 4 2

1 8 6 4 2

1 8 6 4 2

1 8 6 4 2

1 8 6 4 2

F/H

F/H

F/H 1

F/H

F/H

F/H

F/H

F/H

F/H

F/H

F/H

F/H

6K25 e e with IGMP-L2 mode -

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

LK/ACT

1 8 6 4 2

F/H

16 14 12 10 8 6 4 2 F/H

F/H 1

1 8 6 4 2 F/H

traffic and minimize congestion.

network as per the requirement

LK /ACT

LK /ACT

LK/ACT

LK/ ACT

LK/ ACT

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

LK/ ACT

LK/ ACT

16 14 12 10 8 6 4 2

16 14 12 10 8 6 4 2

1 8 6 4 2

1 8 6 4 2

1 8 6 4 2

1 8 6 4 2

F/H

F/H

F/H 10/10

F/H

16 14 12 10 8 6 4 2 F/H

F/H

F/H

F/H

F/H

F/H

F/H

F/H 1

1 8 6 4 2 F/H

F/H

F/H

effectively.

LK/ACT

LK/ACT

LK/ACT

16 14 12 10 8 6 4 2

1 8 6 4 2

F/H

F/H

F/H 1

F/H

F/H

F/H

Show 29 more labels / short text on this page
10/ 100 · 10/ 100 · 10/10 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/ 100 · 10/ 100 · 10/ 100 · 10/ 100 · 10/10 · 10/10 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/100 · 10/ 100 · 10/100 · 10/100
Page 27 of the GarrettCom 6K25e user manual — 3.0 Installation
Page 27 · click to enlarge
Page 27

requirement and 16 10/100 RJ-45 ports to feed the other needs of equipment connected to

1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment

2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate airflow must be maintained for proper and

3.) If the equipment is mounted in an enclosed or multiple rack system, placement of the equipment must not overload or load

4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent

because they have rubber feet they can also be installed on a shelf or table top unit. The

compact size allows it to be easily placed in an office or lab area, and it can also be either

shelf of wall-mounted (see Section 3.3.1 below). Figure 3.1: Location of the Magnum

belong to one group and provide an effective solution for bandwidth. The SNMP option

Equipped with IGMP-L2 mode enhanced features allow the Magnum 6K25e to

meet the fastest growing application of video monitoring or video surveillance

5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and

7.) CB-Circuit breakers of 10Amps should be shown on top of the Rack.

The Dual Giga option on each of the two slot add 4 Gigaport to handle the bandwidth

option will be an additional feature to take care of temperature and power option issue.

demand of industry and provide an economical and effective solution to meet

securely. The versatile mechanical design with rack mounting capability and AC/DC

Before installing the equipment, it is necessary to take the

6.) 24vdc, -48vdc, and 125vdc must be installed in restricted access locations.

GarrettCom 6K25e — LK/ACT diagram (page 27)
Fig. 9

the 6K25e. The robust Tag based vlan feature will able to segregates different ports

and secure web based will allow the remote capability and monitoring the network

overloading of the building/s electrical circuits.

is dependent on the physical layout of the network.

other. These Switches are typically rack mounted in

Magnum 6K25e Switches, as well as connection of

3.1 Locating Magnum 6K25e Switches

The location of a Magnum 6K25e Switch

Typically the Switch is placed in a central wiring

location where groups of network devices need to

must be less than or equal to 500C.

This section describes installation of the

be connected in order to communicate with each

a wiring closet see Section 3.3.2 below), but

uncompromised earthing path.

unevenly the rack system.

following precautions:

the various Ethernet media types.

3.0 Installation

safe operation.

that expectation.

6K25e’s cooling fans

Page 28 of the GarrettCom 6K25e user manual — Copper:
Page 28 · click to enlarge
Page 28

The Magnum 6K25e Switches are specifically designed to support all

individually selected and configured per-port. See Section 2.4 for a description

10BASE-T and 100BASE-TX twisted pair 100m (328 ft) 6K8-RJ45

2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue

protect it from accidental damage in a lab or workplace setting. Maintain an open view

that cooling can occur from the small fan on the left side, while the unit is in operation.

1. Before connecting the fiber optic cable, remove the protective dust caps from the

dampened in alcohol. Make certain the connectors are clean before connecting.

of the front to visually monitor the status LEDs. Keep an open area around the unit so

The following procedure applies to installations using a PM with ST-type fiber

The various media types supported along with the corresponding IEEE

connectors. This procedure applies to ports using a 6K25e module, MST-type

Locate an AC receptacle that is within six feet (2 meters) of the intended

Magnum 6K25e site. The rugged metal case of the Magnum 6K25e will normally

accomplished by using a family of different port Modules which can be

small form factor mm1 Fiber 2.0km (6,562 ft) 6K8-MTRJ, -MLC small form factor sgl.m1 Fiber 15 km 6KP8- SLC

bands at regular intervals; you must use the color-coded strand on the

IEEE Standard Media Type Max. Distance Port Module

100BASE-FX mm1 Fiber 2.0km (6,562 ft) 6K6-MSC, -MST

standard Ethernet media types within a single Switch unit. This is

sgl.m2 Fiber 5Km GBIC-LXSC

1 mm = multi-mode 2 sgl.m = single-mode 3.2.1 Connecting Fiber Optic ST-type, “twist-lock”

sgl.m2 Fiber 18.0km (95K ft) SSC, SSCL

802.3 and 802.3u standards and connector types are as follows:

100BASE-FX mm1 Fiber 220m ( ft) GBIC-SXSC

associated ports at each end of the fiber optic segment.

3.2 Connecting Ethernet Media

of the PMs.

See figure below.

Copper:

port.

Fiber:

Page 29 of the GarrettCom 6K25e user manual — 3.2.3 Connecting Single-Mode Fiber Optic
Page 29 · click to enlarge
Page 29

The following procedure applies to installations using a PM with SC-type fiber

(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx

fiber allows full bandwidth at longer distances, and may be used to connect 10 Mb nodes

media types100BASE-TX and 10BASE-T. CAT 5 cables should be used when making

mixed-speed network, since dual-speed ports are auto-sensing for either 10 and

connection has been established at both ends (and when power is ON in

connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable

The RJ-45 ports of the Magnum 6K25e can be connected to the following two

100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100

3. Connect the Transmit (TX) port (light colored post) on the Magnum PM to the

Receive (RX) port of the remote device. Begin with the color-coded strand of

(TX) port of the remote device. Use the non-color coded fiber strand for this.

5. The LINK LED on the front of the PM will illuminate when a proper

improper cable polarity. Swap the fiber cables at the PM connector to

are the diameters of the core and the core plus the cladding respectively). Single-mode

3.2.4 Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or Shielded)

Twisted Pair (CAT 3, 4, 5) 10BASE-T RJ-45

4. Connect the Receive (RX) port (dark colored post on the PM) to the Transmit

the unit). If LINK is not lit after cable connection, the normal cause is

When connecting fiber media to SC connectors, simply snap on the two square male

When using single-mode fiber cable, be sure to use single-mode fiber port

The same procedures as for multi-mode fiber applies to single-mode fiber

Twisted Pair (CAT 5) 100BASE-TX RJ-45

and 100Mb) be used whenever possible in order to provide flexibility in a

Media IEEE Standard Connector

connectors into the SC female jacks of the 6KPM until it clicks and secures.

3.2.2 Connecting Fiber Optic SC-type, "Snap-In"

connectors. Follow the steps listed in Section 3.2.2 above.

connectors, i.e., using 6K-MSC, 6K-SSC single-mode.

3.2.3 Connecting Single-Mode Fiber Optic

the cable for this first TX-to-RX connection.

up to 10 Km apart, or 18Km with the 6K-SSC.

remedy this situation.

100Mb/s.

meters (328 ft).

Page 30 of the GarrettCom 6K25e user manual — LK/ACT
Page 30 · click to enlarge
Page 30
1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is
2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is

could produce kigh (greater than 2500V ) levels of ground potential rise (GPR)

1613specifications for zero packet loss with fiber ports & with RJ45 ports used as indicated here.

either case, the maximum distance for unshielded twisted pair cabling is 100 meters (328

Mb and 1000Mb) be used whenever possible in order to provide flexibility in a

The following procedure describes how to connect a 10BASE-T or 100BASE-

The RJ-45 Gigabit ports of the Magnum 6K25e can be connected to the media

The following procedure describes how to connect a 1000BASE-T twisted pair segment

1. 1000Base-T connections require that all four pairs or wires be connected. Insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port.
2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be

TX twisted pair segment to the RJ-45 port. The procedure is the same for both

telecommunication multiplexers installed in close proximity (i.e., less than 2

types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)

balanced cable is recommended to use when making 1000BASE-TX connections. In

to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted

substation applications to interface to field devices across distances which

balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)

advises that, for substation applications, the RJ-45 ports are intended for

meters or 6.5ft) to the 6K25e. It is not recommended to use these ports in

3.2.5 Connecting Twisted Pair (CAT5E or better, Unshielded or Shielded)

ft). See Section 4.3 for manual Up-Link switch on port 1 of copper port modules.

Media IEEE Standard Connector

shielded, either unshielded or shielded cables and wiring may be used.

connectivity to other communication equipment such as routers or

Twisted Pair (CAT 5E) 1000BASE-T RJ-45

during line-to-ground fault conditions. The 6K25e passes the

unshielded and shielded twisted pair cables.

cables and wiring may be used.

mixed-speed network.

pair cables.

established

Page 31 of the GarrettCom 6K25e user manual — 3.2.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceivers
Page 31 · click to enlarge
Page 31
GarrettCom 6K25e — LK/ACT diagram (page 31)
Fig. 10

TX RX Bail clasp

communications for both telecommunication and data communications applications. Due

3.2.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceivers

to its compact, hot pluggable characteristics, SFPs are becoming a very popular choice

All SFPs used in Magnum 6KQs are compliant with the industry standard Multi-Source

Side View ---Duplex LC connector -- Front view

damage the fiber cable, cable connector or optical interfaces. It is advised not to remove

higher cabling. The maximum length supported on copper 1000BASE-T is 100mts (328

The small form-factor pluggable (SFP) is a compact optical transceiver used in optical

standard Gb-SFPs and Gb-SFPCU (copper) for user selection of the SFP gigabit media

other device, it is recommended to use Crossover RJ-45 (4-twisted pair) category 5 or

connecting to any Server/workstation. While connecting with any Switch/repeater or

for various applications. The small-chassis Magnum 6KQ is designed for industry-

removing the SFP transceiver for any reason. Not removing the fiber cable first can

illuminated when the unit is powered and proper connection is established

Agreement (MSA) ensuring compatibility with a wide range of networking kit.

recommended to use a straight-through RJ-45(4-twisted pair) connection while

and insert a SFP transceiver frequently as this may shorten its useful life.

since the SFP modules are static sensitive devices.

GarrettCom 6K25e — 3.2.6 Gigabit SFP (Small Form-factor Pluggable) Optical Transceivers diagram (page 31)
Fig. 11 · 3.2.6 Gigabit SFP (Small Form-factor Pluggable) Opti…

type as desired.

ft.).

Page 32 of the GarrettCom 6K25e user manual — F/H ACT
Page 32 · click to enlarge
Page 32

The Magnum 6K25e Manageable Switches can be easily mounted on a table-

top or any suitable horizontal surface, and has four rubber feet to provide stability

The various SFPs transceivers supported by GarrettCom 6K25e, D slot are-

1 3 5 7 10/100 LK

10/100 LK 2 4 6 8 F/ H ACT

F/H ACT

GarrettCom 6K25e — F/H ACT diagram (page 32)
Fig. 12

SFP-ZX70 Gb ZX, 1550nm wavelength, 70km

1 3 5 7

10/100 LK

F/H ACT

2 6 TX RX TX LK RX LK

F/H ACT

F/H

ACT

Magnum 6K25 1 3 5 7 10/100 LK

10/100 LK 2 4 6 8 F/ H ACT

F/H ACT

3.3 Table-Top or Shelf Mounting

GARRETT

finished surfaces.

Show 7 more labels / short text on this page
distance · Magnum QS5116 · Magnum QS5116 PWR · Fiber Switch · Managed Fiber · Switch · without scratching
Page 33 of the GarrettCom 6K25e user manual — 10/100 L 2 4 6 8 F/ H AC
Page 33 · click to enlarge
Page 33

3.3.1 Rack-mounting (for 19” RETMA racks), regular Magnum 6K25es Installation of a Magnum 6K25e Fiber Switch in a 19” rack is a simple

6K25e unit). These brackets attach to the front sides of the Switch (regular package, i.e., not the Reverse version), which is then typically fastened into a standard 19” RETMA

mounting purposes. The 23” and the ETSI brackets are mainly used for larger equipment

The bracket mounting holes in the sides of the Magnum 6K25e permits it to be

mounted in various ways. The same holes fit all three types (19”, ETSI, 23”) of brackets.

attached flush with the front, or attached in the center for a set-back mounting which may

The optional 23” brackets and the ETSI (21”) brackets each come as a pair in a

LED status indicators should be in plain view and easy to read. Rack-mount installation

also available (optional) for rack-mounting of Magnum 6K25e Switches. These brackets

procedure. The units are 1U (1.70”) high. When properly installed, the front-mounted

The 23” brackets and the ETSI (European metric, approx. 21”) brackets are

requires special 19” rack-mounted brackets and screws (included with each Magnum

are popular in the Telco industry where they are a standard for Central Office rack-

The mounting for the 23” is illustrated in Figure 3.3.1 below. The brackets may be

assemblies in rack-mounting frames where the rack-mount equipment is typically

Fig 3.3.1 Mountings for Magnum 6K25e units rack-mounted in a frame

GarrettCom 6K25e — LK/ACT diagram (page 33)
Fig. 13

10/100 L 2 4 6 8 F/ H AC

10/100 L 2 4 6 8 F/ H AC

10/100 L 2 4 6 8 F/ H AC

10/100 L 2 4 6 8 F/ H AC

accessed in operation from both sides.

10/100 L 2 4 6 8 F/ H AC

10/100 L 2 4 6 8 F/ H AC

10/100 L 2 4 6 8 F/ H AC

10/100 L 2 4 6 8 F/ H AC

reduce cabling torque.

rack as shown here.

Show 4 more labels / short text on this page
Mid-Range Mount or · 23” Mount Bracket · 5” Set-Back Bracket · Standard Flush
Page 34 of the GarrettCom 6K25e user manual — D D C C B B A A
Page 34 · click to enlarge
Page 34

AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz.

With each bracket type, there are three different mounting options is shown in

Fig. 3.3.2. The case of the Magnum 6K25e has mounting holes prepared for each of the

mounting arrangements. Users may choose the mounting arrangement most suitable for

The Magnum 6K25e Switches incorporate an internal universal power supply

The 25-port units will consume over 20 watts of power typically. When connecting the

package, along with the necessary screws for attaching the brackets to the sides of the

3.3.2 Rack-mounting, Reverse version of the Magnum 6K25es The optional Reverse Magnum 6K25e Model has all of the cabling (Ethernet

cabling, power cabling and console port cabling) connectors in the rear, and the status

LEDs in the front. The status LEDs that are co-incident with the ports are still present

there, and a second or dual set of LEDs are used for status visibility in the front of the

frame or the 23” frame or ETSI (21”) frame. The 19” brackets are included with each

3.3.2 Reverse

manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard power

The auto-ranging power supply supports installation environments where the

There are three options of brackets available to mount in the standard 19”

and have a recessed male IEC connector for the AC power cord at the left-rear. A

3.4 Powering the Magnum Managed Fiber Switch

cord is supplied with each unit shipped within the United States and Canada.

Magnum Switch unit. They must be ordered as line items.

GarrettCom 6K25e — LK/ACT diagram (page 34)
Fig. 14

unit, the other two may be purchased if desired.

unit, showing the same data.

D D C C B B A A

Show 13 more labels / short text on this page
installation · in a frame · Magnum · mounted · Fig · 6K25e units, · their · rack- · Mid-Range Mount or · 5” Set-Back Bracket · Rear Mount Bracket · Standard Flush · Mount Bracket
Page 35 of the GarrettCom 6K25e user manual — LK/ACT
Page 35 · click to enlarge
Page 35

connected or disconnected without concern for AC power-related problems or damage to

3.4.1 Alarm Contacts for monitoring internal power, and Software Traps The Alarm Contacts feature, optional on Magnum 6K25e’s, provides two

The AC or DC power input connection is in the same panel. A manual On-Off Switch for

enabled, the Form C Normally Closed (NC) contact is held close during normal software

The second (bottom position) NC Alarm Contact is held close when there is

power down condition or by the failure of the power supply inside of the Magnum 6K25e

1. There is four terminal block (1,2,3,4)provided next to AC/DC power supply 2. The top two pins (1,2) are software operated 3. The bottom two pins (3,4) are hardware operated 4. By default it is NC (normally closed) 5. The software operation need to be enable and set to get the Alarm traps. For detail information about the Software Alarm and software control of SNMP alarm traps, please

Power supply options are available to suit the 6K25e Switches to special high-

The first NC Alarm Contact (top position) is a “Software Alarm”, operated

feature with a software configuration command if desired. When the Software Alarm is

Ethernet cabling, there is no need to power down the unit. Individual segments can be

See the Appendices of this manual for more details. Use an RFQ for other variations.

Form C Normally Closed (NC) contacts to which the user can attach two sets of status

monitoring wires at the green terminal block. When this option is present, the terminal

block for Alarm Contacts is part of the Power Input panel in the Magnum 6K25e case.

operation. A user-defined software malfunction, such as an SNMP Trap or a Software

because the NC contacts will open when internal power is lost, either from an external

power to the unit is not available on 6K25e units with the Alarm Contacts option, as

Security violation or an S-Ring Fault, causes the contact to open and thus trigger an

availability communications and/or heavy industrial-grade applications, including:

by user settings in the MNS-6K software. The user can disable the Software Alarm

power on the main board inside of the 6K25e. This provides a “Hardware Alarm”

reference the Magnum MNS-6K Software User Manual. (Chapter 19th).

* -48VDC, 24VDC and 125VDC with dual-source DC input,

* -48VDC, 24VDC and 125VDC with single DC input,

these two features occupy the same space in the case.

Switch. Useful info. about Alarm contacts:

alarm in the user’s monitoring system

the unit.

Page 36 of the GarrettCom 6K25e user manual — STOP!!!
Page 36 · click to enlarge
Page 36

contains (Daughterboard (Bigger) and Granddaughter board (smaller), three 5/8

for an available front-mounted slot must be removed. The following procedure describes

The Magnum 6K25e Switches are normally received from the factory with all

Front panel face plate package. The Front panel faceplate package includes 3

mixed with other Fiber combo 6KPM card packages. Always install the PM

required 6KPM modules installed. There may be situations where 6KPM cards need to

be added or replaced. In cases where additional 6KPM cards are needed, the faceplate

1. Make sure the 6KPM Card package has all necessary accessories to install it

properly. Each 6KPM Card package except the Gigabit, for field installation

stand offs for Granddaughter board, six #4-40 Pan-Head screws along with

Granddaughter board. The copper 6KPM card should not work properly if

The Magnum 6K25e chassis are combined with top and bottom parts and

equipment) are sensitive to static discharge. Use proper ESD measures when

Failure to do so may result in damage to the unit

from the chassis before attempting to remove

for all powers single or dual, is unplugged

Be sure the power cord and connections

3.5.1 Preparation for Installing and Removing 6KPMs

and/or replace any PM cards.

module separately one by one to avoid the mixing.

and will void the warranty.

3.5 6K25e Port Module (6KPM) Installation

retainer brackets and six #2-56 flat head screws.

STOP!!!

2. Remove Chassis Cover

handling port modules.

this operation.

Page 37 of the GarrettCom 6K25e user manual — LK/ACT
Page 37 · click to enlarge
Page 37

assembled together with the help of 22 Philips-head screws. There are 7 screws located

on the front-bottom and rear-top of the unit and four screws each on the sides. Remove

these screws. Once these are removed, the top cover is easily lifted off the chassis base.

position, but unscrew only four of the screws as shown in Fig. below. These screws are

Looking down into the Magnum 6K25e unit, notice that there are individual

PM installation spaces and female latch(white) connectors provided on the main board

Looking into the vertical placed Chassis cover of the unit, there are three brackets with

also used to secure the individual 6KPM cards screen plate which can be subjected to

retaining screws (#256 flat head ) which hold each PM Face plate card slot securely.

When the chassis top cover has been removed, the interior of the unit is exposed.

There are four PM slots (A, B, C and D) located on the front of the chassis cover.

These six screws shown in the picture below are used to secure a PM face plate in

GarrettCom 6K25e — LK/ACT diagram (page 37)
Fig. 15

along with four stand-off’s for each 6KPM card position. (See Figure 3.5.1b).

GarrettCom 6K25e — LK/ACT diagram (page 37)
Fig. 16
Figure 3.5.1bMagnum 6K25e, Top view without chassis cover
Figure 3.5.1cTop View – 6KPM retaining screws hold Face Plate

significant forces from the attached cables. (See Figure 3.5.1c)

3. Remove front panel face plate retaining screws
Figure 3.5.1aRemoving Chassis Cover
Page 38 of the GarrettCom 6K25e user manual — 3.5.2 Installing 6KPM Cards in the Magnum 6K25e
Page 38 · click to enlarge
Page 38
GarrettCom 6K25e — LK/ACT diagram (page 38)
Fig. 17

Up to four front-mounted 6KPM cards may be installed in one Magnum 6K25e

2. Placed Granddaughter board (as shown in fig. 3.5.2a and 3.5.2b) on the chassis

Fig 3.5.2b Granddaughter Board placed in slot

built in stand off (female) provided at the front of the 6K25e Main Board and

Granddaughter board The 5/16 stand off has been used to place the daughter

A and secured with three 7/16 stand-off’s

3. The figure here illustrates the basic layout of an individual PM card. Each

screw down tightly with the three 5/16 stand-off (male) on the top of the

board on the top of the granddaughter board and latch it securely.

Managed Fiber Switch unit. Follow these steps to install a 6KPM.

1. Remove top chassis cover. See procedure in Section 3.5.1 above.

3.5.2 Installing 6KPM Cards in the Magnum 6K25e

6KPM card fits into the space provided on the main board.

GarrettCom 6K25e — 3.5.2 Installing 6KPM Cards in the Magnum 6K25e diagram (page 38)
Fig. 18 · 3.5.2 Installing 6KPM Cards in the Magnum 6K25e

Fig 3.5.2a Granddaughter Board

shown separately

Page 39 of the GarrettCom 6K25e user manual — LK/ACT
Page 39 · click to enlarge
Page 39

copper 10/100 ports. Port# 1

Can be configured as uplink

(x) crossed ports for

GarrettCom 6K25e — LK/ACT diagram (page 39)
Fig. 19

Fig. 3.5.2c Daughter Board,

4. Hold the daughter board with both hands at the end and align the two cream

Fig 3.5.2d Daughter

Fig. 3.5.2e Magnum 6KPM daughter board aligned with the bottom

top view of version for 4

as shown in the Fig.

Board shown upside down with two male latch connectors

GarrettCom 6K25e — LK/ACT diagram (page 39)
Fig. 20
GarrettCom 6K25e — LK/ACT diagram (page 39)
Fig. 21

female connector for the installation

placed at the bottom of

the daughter board with

connector placed on the

main board. As shown

below in Fig. 3.5.2e

Show 6 more labels / short text on this page
cascading · Granddaughter and · connectors (male) · the other female · color latching · Uplink
Page 40 of the GarrettCom 6K25e user manual — LK/ACT
Page 40 · click to enlarge
Page 40
GarrettCom 6K25e — LK/ACT diagram (page 40)
Fig. 22

operational. When leaving 6KPM slots empty, always use a face plate (Magnum 6K8-

BLNK) to cover the slot opening in the front panel. This will maintain proper cooling

GarrettCom 6K25e — LK/ACT diagram (page 40)
Fig. 23
7. Once the installation of granddaughter and daughter modules is done, the front

complete the installation process for that port module. The front panel screen

Figure 3.5.2fSecurely latching up 6KPM Cards into a Magnum 6K25e
Fig. 3.5.2g Top View6KPM Module installed inside a

panel screen plates need to be placed on the front of the chassis cover to

plate comes along with the package of port module separately along with

air flow, safety, and operation as required by FCC, CE, and other regulations.

slowly and firmly with two

properly and the mounting

fingers (as shown below in

Fig. 3.5.2f) on the top of

below shows the top view

holds the daughter board

holes are aligned with

daughter board with 6

#440 screws, so that it

6KPM cards inside the

stand offs then press

latched up securely.

6. Now screw down the
5. Once the latching

securely. The figure

of 6KPM card after

Magnum 6K25e.

Show 5 more labels / short text on this page
successfully installing the · connectors are aligned · the latching connectors · until the connectors · 6K25e
Page 41 of the GarrettCom 6K25e user manual — screen plates installed inside the chassis cover using brackets and screws
Page 41 · click to enlarge
Page 41
GarrettCom 6K25e — LK/ACT diagram (page 41)
Fig. 24

COTX require four bracket extender for each(slot A, B, or C COTX). Attach the bracket

GarrettCom 6K25e — LK/ACT diagram (page 41)
Fig. 25

from the PCA to the center standoff on the main mother board. The bracket provide

the stability to the Gigabit module. The slot D can be configured with dual Gigabit

Fig. 3.5.2h Inside view of chassis cover (from the rear), showing the front panel

To properly remove a 6KPM card from the 6K25e Managed Fiber Switch,

brackets and 6 #256 flat head screws. The brackets and screws have been

8. Once all 6KPM cards have been installed (including faceplates for empty

slots), the chassis cover should be replaced. Make sure the chassis cover is

2. Remove retaining screws placed on top for the 6KPM and Face Plate

screen plates installed inside the chassis cover using brackets and screws

1. Remove chassis cover See procedures in Section 3.5.1 above.

SFP ordualRj-45 or dual combo of SFP & RJ-45 modules only.

installed inside of the top cover as shown in Fig. 3.5.2h.

aligned properly before securing the enclosure.

checking the speed, F/H, and activity status)

the chassis. The screen faceplate screws out from

the inside front of the chassis cover by loosening

On the top of the daughter module there are six

standoffs holding the Granddaughter board with

position (see Figure 3.5.3a). Remove the three

retaining screws for each 6KPM card. These

screws are used to secure a 6KPM card in

3.5.3 Removing 6KPM Cards

follow the 3 steps below.

Page 42 of the GarrettCom 6K25e user manual — Console (DB-9) Por t
Page 42 · click to enlarge
Page 42
GarrettCom 6K25e — LK/ACT diagram (page 42)
Fig. 26

6K25e Switch configuration for Network Management, please refer to Magnum 6K25e

the 4 screws and bracket while holding it down firmly. Figure 3.5.3a: Top View - 6

Use a DB-9 “null modem” cable to connect the Magnum6K25e Console Port

Software Manual available on GarrettCom‘s FTP site. Detail info. about the MNS is

Rear View of Magnum 6K25e, (Typical Console Port is on the Rear of Reverse

(the RS-232 port on the 6K25e Switch) to the your PC, so that your PC

that has been removed, follow the steps as described for installing a 6KPM card

3.6 Connecting the Console Terminal to Magnum 6K25e

O

OF

available on 2.2.9 ( see page no. 13) of this manual.

becomes the 6K25e’s Console Terminal.

a 6KPM-BLNK face plate cover.

the board near the latch-up connectors as

slot is to remain unused, be sure to install

If another 6KPM card is replacing the one

out the daughter board from the latching

connectors, using both hands, gripping

shown in Fig. 3.5.3b . If the now empty

retaining s crews shown by arrows

Carefully and gently pull

Figure 3.5.3bRemoving a 6KPM
3. Remove 6KPM Card

discussed in Section 3.5.1.

package.

Console (DB-9) Por t

(Management)

CONSOLE

PORT

6K25e Models) · Card

Page 43 of the GarrettCom 6K25e user manual — 4.1 Switching Functionality
Page 43 · click to enlarge
Page 43

intended for temporary connectivity to other equipment such as PCs. Since the

among all of its ports. The Magnum 6K25e supports10/100Mbs for copper media and 10

network performance. All ports can communicate to all other ports in a Magnum 6K25e,

terminal) to connect directly to the switch using a straight through cable.(Note:

or 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and

3.6.1 RS-232 (DB-9) Console Com port (Serial port) pin assignments.

The above provided information enables a managed station( a PC or Console

The Null-Modem (DB-9) cable is optional and can be order from the factory,

console port connection is temporary, it is excluded from IEEE 1613 packet-

advises that, for substation applications, the serial RJ-45console ports are

This chapter describes the functions and operation of the Magnum 6K25e

A Magnum 6K25e provides switched connectivity at Ethernet wire-speed

but local traffic on a port will not consume any of the bandwidth on any other port.

1 CD Carrier detect (not used)

3 TXD Transmit Data (output)

Pin Signal Description

2 RXD Receive Data (input)

loss testing per the 1613 standard-defined test procedure.

5 GND Signal Ground

4 open not used

6-9 open not used

Pin 5 Pin 1

DB-9 (Console port connector)

4.1 Switching Functionality

4.0 OPERATION

along with the unit

Switch.

Page 44 of the GarrettCom 6K25e user manual — 4.2 Status LEDs
Page 44 · click to enlarge
Page 44

Each time a packet arrives on one of the switched ports, the decision is taken to

either filter or to forward the packet. Packets whose source and destination addresses are

on the same port segment will be filtered, constraining them to that one port and relieving

is on another port segment will be forwarded to the appropriate port, and will not be sent

PWR : Power LED, ON when external power is applied to the unit.

ACT : ON with port activity for 10 Mbps and 100Mbps operation.

The upper part of the copper port module has a manual Up-link switch, located

100Mbps selection for the switched ports must be configured through MNS software per

the rest of the network from having to process them. A packet whose destination address

to the other ports where it is not needed. Traffic needed for maintaining the operation of

mode, which eliminates bad packets and enables peak performance to be achieved when

All Magnum 6K25e units have address table capacities of 4K node addresses

removed or moved from one segment to another, the 6K25e Switch automatically keeps

An address-aging algorithm causes least-used addresses to fall out in favor of

LK : Steady ON, Link status for 10 Mbps and 100Mbps operation.

configuring necessary to be done for basic operation at installation or for maintenance.

(resides inside the unit) on the 6K8-RJ45. Optional Half / Full duplex mode and 10 or

100/10 : Speed LED, ON when the speed is 100Mbps , OFF when the speed is 10 Mbps

The only hardware configuration settings are user options for an UP-LINK Switch

The Magnum 6K25e Switches operate in the store-and-forward switching

frequently-used addresses. To reset the address buffer, cycle power down-and-up.

Magnum 6K25e units are plug-and-play devices. There is no software

suitable for use in larger networks. They are self-learning, so as nodes are added,

F/HFull / Half duplex LED, ON when the port is running full

4.3 Up-link MDI-MDIX on RJ-45 port modules, for port 1 only

unit as per the requirement. The internal functions of both are described below.

the network (such as occasional multi-cast packets) are forwarded to all ports.

duplex, OFF for half duplex.

For all Magnum 6K25e models :

there is heavy traffic on the network.

up with node locations.

4.2 Status LEDs

Filtering and Forwarding · Address Learning

Page 45 of the GarrettCom 6K25e user manual — LK/ACT
Page 45 · click to enlarge
Page 45

The Managed 6K25e-Series Fast Ethernet copper ports, can be set for either fixed 100Mb

copper ports is to connect one of them using a fiber media converter to another Switch in

desirable to operate the fiber link at 100Mb speed, and at either half- or full duplex mode

possible depending on what the other device supports. These are: (1) 100Mb full-duplex,

position as default factory setting, where used for all-copper module or combo modules.

selection is made via MNS software. The factory default setting is for auto-negotiation.

At 10Mb or 100Mb-fixed speed, the user may select half- or full-duplex mode by MNS

When Magnum 6K25e RJ-45 copper ports are set for auto-negotiation and are

connected to another auto-negotiating device, there are 4 different speed and F/H modes

The auto-negotiation logic will attempt to operate in descending order and will normally

switching hub in the network. The manual Up-link switch position is configured as (=)

page no.52) of this manual to access the “6K-MNS(Rel 3.7) Software user guide”

6K25e Switch’s RJ-45 ports handle this situation by configuring the ports as per desire

through MNS software port settings and can check the port status of each port after the

on the inside of the unit on the port module board next to the RJ45 port # 1 which it

The RJ-45 ports independently support auto-cross (MDI or MDIX) in

converter) or fixed mode at 10Mb or 100Mb Half/Full Duplex(managed switch). No

Software for each RJ-45 port separately. For detail information See Section (10.1 at

One frequently-used application for the Managed Magnum 6K25e Switch

depending on the capabilities of the remote device. Standard commercially available

Fast Ethernet media converters mostly do not support auto-negotiation properly, and

require that the switched port to which they are connected be at 100Mb fixed speed.

auto-negotiation mode and will work properly with all the other connected devices

with RJ-45 port whether it supports Auto-negotiation or not (e.g 10Mb Hub, media

speed or for 10/100 F/H N-way auto-negotiation per the IEEE802.3u standard. The

Attachment to 10/100 auto-negotiation ports typically will not work properly. The

controls. It enables the port’s cable to be cascaded (X) to a 10/100Mb repeater or

4.4 Auto-Cross(MDIX) and Auto-negotiation, for RJ-45 ports

cross-over cable is required while using the 6K8’s copper port to other devices.

the network backbone, or to some other remote 100Mb device. In this case, it is

(2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex.

Operation is according to the IEEE 802.3u standard.

change.

Page 46 of the GarrettCom 6K25e user manual — 4.5 Flow-control, IEEE 802.3x standard
Page 46 · click to enlarge
Page 46

may be limited within that collision domain. The Path Delay Value (PDV) bit-times must

attempting to transmit to one 100Mb port, and in other protracted heavy traffic situations.

mode” result can change at any time depending on network changes that may occur). If

burst of activity causes the switch to save frames until its buffer memory is full. This is

arrive at the highest order mode that both devices can support at that time. (Since auto-

-- the devices at both ends of the cable are capable of operation at either 10

  • NOTE – Some NIC cards only auto-negotiate when the computer system

When operating in 100Mb half-duplex mode, cable distances and hop-counts

account for all devices and cable lengths within that domain. For Magnum 6K25e Fast

negotiation is potentially an externally controlled process, the original “highest order

the device at the other end is not an auto-negotiating device, the 6K25e’s RJ-45 ports

will try to detect its idle signal to determine 10 or 100 speed, and will default to half-

Auto-negotiation per-port for 802.3u-compliant switches occurs when:

that they are in is powered up. These are exceptions to the “negotiate at

Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.

Magnum 6K25e Switches incorporate a flow-control mechanism for Full-

Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long

most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the

-- the second of the two connected devices is powered up*, i.e., when

10Mb port is unable to keep up. It can also occur when multiple 100Mb ports are

LINK – enabled” rule above, but may be occasionally encountered.

-- the LINK is re-established on a port after being lost temporarily.

Mb or 100Mb speed and/or in full- or half-duplex mode, and can

send/receive auto-negotiation pulses, and . . .

4.5 Flow-control, IEEE 802.3x standard

duplex at that speed per the IEEE standard.

LINK is established for a port, or

General information -

Page 47 of the GarrettCom 6K25e user manual — (LXSC40)
Page 47 · click to enlarge
Page 47

switch prevents frames from entering the device by forcing a collision indication

and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LXSC25)

and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (LXSC70)

buffer queue increases, the Switch will send a “RESUME" packet to tell the transmitter

802.3x flow control standard in order to communicate properly during normal operation. Note: When in Half-Duplex mode, the 6K25e Switch implements a

Lucent’) web sites and catalogs to provide guidance to network designers and installers.

6 7 4.8

Magnum 6K25e Switches implement the 802.3x flow control (non-blocking)

transmitting device is commanded to stop transmitting into the 6K25e Switch port for

sufficient time to let the Switch reduce the buffer space used. When the available free-

allows the available buffer space to improve as the switch catches up with the

4.6 Power Budget Calculations for Magnum 6K25e PM’s with Fiber Media

Receiver Sensitivity and Transmitter Power are the parameters necessary to

The following data has been collected from component manufacturer’s (Agilent’s and

on Full-Duplex ports, which provides for a “PAUSE” packet to be transmitted to the

sender when the packet buffer is nearly filled and there is danger of lost packets. The

to start sending the packets. Of course, the transmitting device must also support the

on the half-duplex ports that are receiving. This temporary “collision” delay

compute the power budget. To calculate the power budget of different fiber media

where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,

back-pressure algorithm on 10/100 Mb ports for flow control. That is, the

OPB,

17 23.5 13.5

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

installations using Magnum products, the following equations should be used:

and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

5 5.9 3.4

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

OPB,

14 19.5 19.5

Sens.

PR ,dB

PT , dB

OPB (Optical Power Budget) = PT(min) - PR(min)

traffic flow.

Mode 2 (2) 850 62.5/125 100/140 50/125

Mode Std.

6KP4- F10ST 10Mb FL Multi-

Std.

(LXSC40)

Show 26 more labels / short text on this page
typical* · distance · Km, fdx · typical · dB · distance · Worst* · Km, fdx · Worst · dB · R’cvr · X’mitr · Output · Cable · Size · µm · Wave · length · nm · km · fdx · (hdx) · Speed, · Fiber · Module · Port
Page 48 of the GarrettCom 6K25e user manual — Modules
Page 48 · click to enlarge
Page 48
GarrettCom 6K25e — LK/ACT diagram (page 48)
Fig. 27

mode 18+ (0.4) 1300 9/125 -15 -31 14 28 17.5 35

mode 40 (0.4) 1300 9/125 -5 -34 29 58 32.5 65

mode 2 (0.4) 1300 62.5/125 -19 -31 12 4 16 5.7

Mode 15+ (0.4) 1310 9/125 -15 -28 11 22 - -

1000Mb Multi- mode 0.55 1300 62.5/125 50/125 -9.5 -17 5.5 2 12.5 4

1000Mb Single- mode 10 1300 9/125 -9.5 -20 8.5 17 10.5 21

1000Mb Single- mode 25 1550 9/125 -4.0 -21 15 37.5 17.5 43

1000Mb Single- mode 40 1550 9/125 -4.0 -21 15 60 17.5 70

1000Mb Single- mode 70 1550 9/125 -3.0 -23 18 90 20.5 102

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only

  • The worst-case OPB of the fiber link must be greater than the fiber cable’s
  • The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the

full-duplex (factory default) setting for 100Mbps fiber ports must be used,

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

5.0 Introduction - Magnum 6K25e Managed Fiber Switch Port

This chapter describes each Port Module (PM), including appearance,

if the following factors are both applied:

functionality, and status displays.

passive Attenuation.

Modules

and

Page 49 of the GarrettCom 6K25e user manual — 5.2 6KPM Module Description
Page 49 · click to enlarge
Page 49

during shipment or delivery. Inspect the contents of this package for any signs

Modules for flexible mixed-media connectivity to RJ-45 and fiber media. Since

the Magnum 6K25e Switches have dual-speed capability for copper ports, the 6

or 8-port interfaces are designed to support all standard Ethernet media types at

RJ-45 ports or used for COMBO module is set as (=) other user ports.

installing a 6K25e PM; notify the carrier of any damage you believe occurred

keep the shipping container should you need to ship any of the PMs separately

Each 6K25e PM is individually described in the following sections.

This section applies only to PMs shipped as separate items, i.e., 6K25e PMs

Remove the 6K25e PM(s) from the shipping container. Be sure to

connecting Ethernet segments with its individual connector type and media.

at a later date. In the event there are items missing or damaged, contact your

supplier. If you need to return the unit, use the original shipping container if

An important feature of the Magnum 6K25e is the use of Port

For a list of 6K25e Port Module types, refer to Section 1.2

Examine the shipping container for obvious damage prior to

10 or 100Mps speed. Each 6K25e PM provides six or eight ports for

of damage and ensure that the items listed below are included.

Installation instructions, with illustrations

possible. Refer to Chapter 5 for specific return procedures.

not factory installed in a Magnum 6K25e PM slot.

5.1 Inspecting the Package and Product

1 or more 6K25e PMs

5.2 6KPM Module Description

This package should contain:

Page 50 of the GarrettCom 6K25e user manual — ACTIVITY
Page 50 · click to enlarge
Page 50

5.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist lock” Combo Module

10/100Mbps and fiber optic ports at 100MB. The Combo module is equipped with dual-

port supports fiber optic cable distances up the IEEE-standard 100Mbps distance limits,

Link (LK) LED that indicates proper connectivity with the remote device when lit, and

The 6KP6-RJ10ST is a six port combo module that looks similar to

The ST-connector functions as a fiber optic transceiver to support 10BASE-FX network

supports the standard distance 100m on each port and the fiber port supports fiber optic

cable distances up the IEEE-standard 10Mbps distance limits, i.e., typically 2km at full-

Link (LK) LED that indicates proper connectivity with the remote device when lit, and

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The

5.2.1a 6KP6-RJ10ST, 4@10/100Mbps RJ-45 and 2@10Mb multi-mode FX-ST “twist lock” Combo Module

the 100Mb combo module with the exception of 10Mb speed at the ST fiber module.

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The

5.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module

Each port has an Activity (ACT) LED indicating packets being received, a

Each port has an Activity (ACT) LED indicating packets being received, a

10/100 LED indicates the speed, if the LED is ON, 100Mbps if it is OFF, 10Mbps.

10/100 LED indicates the speed, if the LED is ON 100Mbps if it is OFF 10Mbps.

segments. When installed in a Magnum 6K25e Managed Switch, the copper port

4 Port@ 10/100Mbps and 2 @100 Mb ST Fiber Port

The Magnum 6KP6-RJMST is a combo 6 port module of RJ-45’s at

10/100 LK

F/H ACT

4 FULL/HALF

2 6 TX RX TX LK RX LK

1 3 5 7

6KP6-RJMST,

ACT

F/H

LINK 2

i.e., typically 2km at full-duplex and 412m at half-duplex.

ACTIVITY

ACT

F/H

100m on each port and the fiber

mode ST-type connectors and

segments. When installed in a

supports the standard distance

dual speed copper ports. The

ST-connector functions as a

fiber optic transceiver to

Switch, the copper port

duplex and half-duplex.

10/100 · support 100BASE-FX network · Magnum 6K25e Managed

Page 51 of the GarrettCom 6K25e user manual — 5.2.1c 6KP4FLSTFX,
Page 51 · click to enlarge
Page 51
GarrettCom 6K25e — LK/ACT diagram (page 51)
Fig. 28

hub to connect to the switch through 10Mb fiber ports. It supports distances according to

All four fiber ports are ST connectors and configured as 10Mb Half-duplex by default for

provide a convenient way for the half duplex hub to connect to the switch through 10Mb

the 10Base-FL standard i.e, 2Km distance for multi-mode fiber. (Single-mode for 10Km

received, a Link (LK) LED indicating proper connectivity with the remote device when

10Mb fiber and 100Mb Full duplex for the 100Mb fiber. The 10Mb ST-fiber ports allow

the user to connect their legacy 10Mb network to the Magnum 6K25e switch. They also

lit, and FDX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).

Each port has an Activity (ACT) LED indicating packets being

1 ACTIVITY LINK 2

RX

TX RX LK

4 Port@ 10Mb ST Fiber Port

4 Port@ 10Mb ST Fiber Port

LK

6KP4-RJ10MST,

6KP4-RJ10MST,

2 6 T

switch. They also provide a convenient way for the half duplex

ACT

F/H

ACT

F/H

FULL/HALF

TX RX LK

TX RX LK

ACT

ACT

distance may be available as a special order).

F/H

F/H

their legacy 10Mb network

FX-ST “twist

lock” Module

FLSTFX is a combo fiber

module with two 10Mb +

combine 4 ST-Fiber ports.

Fiber ports. All four fiber

and configured as 10Mb

The 10Mb ST-fiber ports

allow the user to connect

2@10Mb & 2@100Mb multi-mode

is a 10Mb multi-mode

fiber module with 4 ST-

ports are ST connectors

Half-duplex by default.

to the Magnum 6K25e

5.2.1c 6KP4FLSTFX,

fiber module and in

The Magnum 6KP4-F10ST · two 100Mb multi-mode · The Magnum 6KP4-

Page 52 of the GarrettCom 6K25e user manual — 6KP6-RJMSSC,
Page 52 · click to enlarge
Page 52

While the functionality of these two modules is essentially the same, the 6KP6-

received, a Link (LK) LED indicating proper connectivity with the remote device when

5.2.3 6KP6-RJSSC 4@ 10/100Mbps RJ-45 Ports and 2@100Mbps single-mode FX-SC-type, “snap-in” connector

distance for multi-mode fiber. (Single-mode for 10Km distance may be available as a

fiber ports. Whereas the 100Mb ST module allow to connect the 100Mb demand of

lit, and FDX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).

4 Port@ 10/100Mbps and 2 @100 Mb SC Fiber Port

GarrettCom 6K25e — 4 Port@ 10/100Mbps and 2 @100 Mb SC Fiber Port diagram (page 52)
Fig. 29 · 4 Port@ 10/100Mbps and 2 @100 Mb SC Fiber Port

Switch devices. It supports distances according to the 10Base-FL standard i.e, 2Km

Each port has an Activity (ACT) LED indicating packets being

5.2.2. 6KP6-RJMSC 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-SC “snap-in” Fiber connector

RJMSC is equipped with an SC-type "snap-in" connector instead of an ST-type.

4 Port@ 10/100Mbps and 2 @100 Mb SSC Fiber Port

4 FULL/HALF

10/100 LK

F/H ACT

FDX / HDX and 10/100 operation, and the same face-plate lettering.

2 6 TX RX TX LK RX LK

supporting four Copper and two single-mode fiber network segments.

6KP6-RJMSC,

1 3 5 7

6KP6-RJMSSC,

ACT

F/H

LINK 2

ACTIVITY

ACT

F/H

transceivers all in one module. This

is similar to the 6K6-RJMST. It has

module equipped with 4 10/100Mb

RJMSC is also a Combo 6 Port

RJ-45 ports along with 2 multi-

the same LEDs indicating port

activity (ACT), Link (LK), and

equipped with 4 dual speed

mode SC-type connectors. It

module of the 6K25e Switch

mode 100Mbps fiber optic

copper ports and 2 Single-

and Fiber functions in one

is also a Combo module

special order).

Show 5 more labels / short text on this page
10/100 · The Magnum 6KP6- · The Magnum 6KP6-RJSSC · through combining copper · provides an advantage
Page 53 of the GarrettCom 6K25e user manual — LK/ACT
Page 53 · click to enlarge
Page 53

copper at the 100m distance. The Fiber is single-mode and cable lengths can be as much

Link (LK) LED that indicates proper connectivity with the remote device when lit, and a

ports and 2 Single-mode (Long Reach) SC-type connectors. It provides a combination of

copper and Fiber functions in one module to the 6K25e Switches, supporting four Copper

The Magnum 6KP6-RJ10ST is also a Combo module equipped with 4 dual speed copper

copper and Fiber functions in one module to the 6K25e Switches, supporting four Copper

5.2.4 6KP6-RJSSCL 4 @ 10/100 Mb copper port and 2@100Mbps single-mode FX-SC-type, “snap-in” connector

The Magnum 6KP6-RJSSC is also a Combo module equipped with 4 dual speed copper

supporting the 100m distance and Fiber supporting single-mode fiber cable lengths of as

10/100 LED indicates the speed for the copper port, which is 100Mbps when the LED is

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The

distinguish the single-mode 6 K6-RJSSC from the multi-mode 6K6-RJMSC, the label

Link (LK) LED indicating proper connectivity with the remote device when lit, and a

5.2.4a 6KP6-RJ10ST 4 @ 10/100 Mb copper port and 2@10Mbps multi-mode FL-ST-type, “twist-lock” connector

ports and 2 multi-mode 10 Mb fiber ST-type connectors. It provides a combination of

The 6KP6-RJSSC, when installed in a Magnum 6K25e Switch operates on

Each port has an Activity (ACT) LED indicating packets being received, a

The 6KP6-RJSSC, when installed in a Magnum 6K25e Switch has copper

Each port has an Activity (ACT) LED indicating packets being received, a

FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). The

The 6KP6-RJ10ST, when installed in a Magnum 6K25e Switch has copper

Activity (ACT) LED indicating packets being received, a Link (LK) LED indicating

supporting the 100m distance and Fiber supporting multi-mode fiber cable allow to

connect the legacy network of 10Mb requirement in the network. Each port has an

10/100 LED indicates 100Mbps speed when lit and 10Mbps speed when off. To

and two single-mode (Long-Reach) fiber network segments.

“Sgl. M.” is at the top of the faceplate of the 6K6-RJSSC.

much as 40+ Km (see Power Budget, Section 4.5)

and two 10Mb of ST fiber network segments.

as 25+ Km (see Power Budget, Section 4.5)

ON and 10 Mb when the LED is OFF.

Page 54 of the GarrettCom 6K25e user manual — LINK
Page 54 · click to enlarge
Page 54

5.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factor

Magnum 6KP8-MTRJ is a multi-mode fiber optic 8-port module equipped with

The functionality of this 100BASE-FX multi-mode 8 Port module is essentially

with two different speeds. The top four ports of MTRJ Small form factor fiber support at

the same as the ST and SC-types. It has the same LEDs per port indicating port activity

The 6KP6-RJ10ST is a combo module with two different kinds of fiber flavor

proper connectivity with the remote device when lit, and a FDX/HDX LED indicating

speed for the copper port, which is 10Mbps when the LED is ON and 10 Mb when the

8 Port@ 100Mbps Multi-Mode Fiber port

5.2.5a 6KP6-MT10ST, 4 @100Mb multi-mode FX , MTRJ Small-Form- Factor and 2@ 10Mb Multi-mode ST-Fiber port

100Mb full-duplex, whereas the bottom two ports multi-mode ST-Fiber support 10Mb

half-duplex. This combo module provides more flexibility to the user to connect their

supports fiber optic cable distances up to the IEEE-standard 100Mbps distance limits,

i.e., typically 2km at full-duplex and 412m at half-duplex. The 10Mb Multi-mode ST-

full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the

FULL/HALF 1 ACTIVITY

When installed in a Magnum 6K25e Switch, the 100Mb MTRJ connector

“small-form-factor”

ACT

F/H

ACT

F/H

ACT

F/H

ACT

F/H

F/H LK LK LK LK

1 3 5 7

2 4 6 8 LK

legacy 10Mb fiber as well as 100Mb to the Magnum 6K25e Switch.

6KP8-MTRJ,

typically 2km at full-duplex and 412m at half-duplex.

LINK

ACT

F/H

ACT

ACT

ACT

F/H

F/H

(ACT), Link (LK), and FDX or HDX operation.

an RJ-45 port, but it is black in

and ease of connection make it

connectivity. When installed in

distances up the IEEE-standard

connector. It looks almost like

color. The MT-RJ’s small size

100Mbps distance limits, i.e.,

a good choice for 100Mbps

a Magnum 6K25e Switch, it

supports fiber optic cable

LED is OFF.

a small-form-factor MTRJ-type · “fiber-to-the-desktop” Ethernet

Page 55 of the GarrettCom 6K25e user manual — F/
Page 55 · click to enlarge
Page 55
GarrettCom 6K25e — LK/ACT diagram (page 55)
Fig. 30

distances as mentioned on 5.2.3. and the

at half-duplex.The compact size of the LC Connector reduces the size of wiring panels in

Fiber connector supports the standard fiber optic distance limit of 2Km at Full and Half-

3 2 4 6 8 LK

When installed in a Magnum 6K25e Switch, it supports fiber optic cable distances up to

the IEEE-standard 100Mbps distance limits, i.e., typically 2km at full-duplex and 412m

technology.The cable end is a “plug-in” connector with both fiber strands terminated in

The functionality of this 100BASE-FX multi-mode 4 port module is

5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX ,

4 Port@ 10/100Mbps & 4 port @ 100Mbps

5.2.7 6KP8-MLC, 8 ports @ 100Mbps multi-mode LC connector Small-

Magnum 6KP8-MLC is a

essentially the same as the ST and SC-types. It has the same LEDs per port

indicating port activity (ACT), Link (LK), and FDX or HDX operation

Switch, it supports the standard

eight-port multi-mode fiber LC

Form Factor

LEDs also act similarly.

wiring closets while providing the advantage of “future-proof” fiber optic

6KP8-45MT

primarily in 100Mbps fiber-to-the-desktop links.

8Port@ 100Mbps multi-mode LC fiber port

MTRJ Small-Form-Factor

FULL/HALF 1 ACTIVITY

copper and fiber (Small Form Factor)

of placing more ports on one module.

10/100 RJ-45 ports and 4 MTRJ fiber

ACT

F/H

ACT

F/H

ACT

F/H

ACT

MTRJ connectors give an advantage

The 6KP8-45MT is equipped with 4

When installed in a Magnum 6K25e

F/H

MTRJ type ports. The small size of

Module is a combo module with

2 4 6 LK LK LK

2 4 6 LK LK LK

LINK

ACT

ACT

ACT

ACT

duplex both.

F/

F/

F/

F/

ports.

connector “small-form-factor” used · Multi-Mode Fiber port · The Magnum 6KP8-45MT

Page 56 of the GarrettCom 6K25e user manual — 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port
Page 56 · click to enlarge
Page 56

more ports on one module. The

6KP8-45LC is equipped with 4

3 F/H ACT

indicating packets being received, a Link (LK) LED indicating proper connectivity with

the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit

copper and Fiber (Small Form

10/100 RJ-45 ports and 4 LC(

Small form factor) multi-mode

6K25e Switch, it supports the

and will allow both unshielded twisted pair (UTP) and shielded twisted pair (STP) cable

one housing that cannot be improperly inserted. Each port has an Activity (ACT) LED

The Magnum 6KP8-45LC Module is a combo module with a combination of

small size of LC connectors

give an advantage of having

When installed in a Magnum

10/100 LK 1

5.2.8 6KP8-45LC, Combo 4@ 100Mbps multi-mode -LC small-form factor and 4@ 10/100 Mbps RJ-45 Connector

Factor) LC type ports. The

standard distances as per mentioned on 5.2.8. and the LEDs also acts similarly as

connections. The 6KP8-RJ45 module is equipped with a Media Dependent Auto-

4 FULL/HALF

2 4 6 8 F/ H ACT

10/100 LK

8 Port@ 10/100Mb Copper ports

1 3 5 7

fiber ports.

5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port

6KP8-RJ45,

LINK 2

ACTIVITY

GarrettCom 6K25e — 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port diagram (page 56)
Fig. 31 · 5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port

4 Port@ 10/100Mbps & 4 port @ 100Mbps

shielded to minimize emissions

standard length. It is equipped

negotiating capability on each

twisted pair segments of any

connector, and offers 10/100

port. The RJ-45 connector is

(or half-duplex when off).

Multi-Mod LC Fiber port

with an eight-port RJ-45

full / half-duplex auto-

mentioned above.

10/100 · The 6KP8-RJ45 · module supports Ethernet

Page 57 of the GarrettCom 6K25e user manual — 6KP8-45RJ
Page 57 · click to enlarge
Page 57

Auto-crossover (MDIX), which allow the RJ-45 ports to automatically Link with any RJ-

GarrettCom 6K25e — LK/ACT diagram (page 57)
Fig. 32

could produce kigh (greater than 2500V ) levels of ground potential rise (GPR)

1613specifications for zero packet loss with fiber ports & with RJ45 ports used as indicated here.

feature eliminates the need for a special twisted pair crossover cable when connecting to

FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off), and a

standard. Only 4 x RJ-

option in one 6K-unit.

available with mix –n-

telecommunication multiplexers installed in close proximity (i.e., less than 2

5.2.10 New PoE(Power Inside), model PI6KP8-45RJ (MDIX), 10/100Mb 8-port

In this Fig. the top 4-

normal MDIX ports.

Each port has an Activity (ACT) LED indicating packets being received, a

Link (LK) LED that indicates proper connectivity with the remote device when lit, a

substation applications to interface to field devices across distances which

match with fiber modules. Please check the ordering information Sec.1.2. for all the

Crossover (MDI-X) switch, which controls all ports for cascaded connection. This

advises that, for substation applications, the RJ-45 ports are intended for

meters or 6.5ft) to the 6K25e. It is not recommended to use these ports in

The PoE RJ-45 ports act similar to regular RJ-45 ports, except they have

IEEE802.3af PoE

45 (10/100) ports maxm. support

capability of providing power on each port to power up the PD devices, per the

connectivity to other communication equipment such as routers or

“10/100” LED indicating 100Mb when lit (or 10 Mbps when off).

10/10 LK/AC 1

3 F/H POE

2 1 3 5

45 device and eliminate the use of cross-over cable.

10/10 LK/AC

4 FULL/HALF

various PI6K PoE modules option.

2 4 6 F/ H POE

8 Port@ 10/100Mb Copper ports

a hub or another switch.

6KP8-45RJ

LINK LK / ACT 2

PoE

Show 8 more labels / short text on this page
bottom 4- RJ-45 are · POE(Power Inside) · enhanced with POE · option whereas as · The 4-RJ45 POE · module are also · RJ45 ports are · 10/10
Page 58 of the GarrettCom 6K25e user manual — PoE
Page 58 · click to enlarge
Page 58

devices. The PoE LED is ON when the attached PD is drawing power from the

15watts to power up the PoE PD devices. In this

ports are enhanced with

POE option The 8-RJ45

PoE LED is ON when connected properly to a 803.af compliant PD device on that port.

When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

through, so the 48VDC power source must be strong enough to provide power

to the 6K switch and to all the 8 RJ-45 ports with PD devices connected (up to

15 watts per PoE port). • In the case where the 48VDC power in not internally connected and no power

5.2.11 New PoE(Power Pass-through), model P6KP8-RJ45 (MDIX), 10/100Mb 8-

input power supply to

POE module are also available with mix –n-match with fiber modules. Please check the

PoE LED is ON when connected properly to a 803.af compliant PD device on that port.

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

  • For non-PoE devices connected, the PoE port will act as a normal RJ-45 port

standard. The Power

(10/100) ports. Each

regular (non-PoE) RJ-45 modules as shown in Fig 2. When the PoE port is in use, the

is coming to the PoE ports for some reason, all the PoE port LEDs are ON

Fig. the top 8-RJ45

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to

simultaneously to indicate a trouble condition. The ports will still operate

The PoE RJ-45 ports act similar to regular RJ-45 ports, except they have

IEEE802.3af PoE

The LEDs on 6KP8-RJ45- PoE module are slightly different compared to

  • For PoE devices, each RJ-45 PoE port supports only 802.3af complaint
  • The PoE ports in Magnum 6K’s with 48VDC power input act as a pass-

capability of providing power on each port to power up the PD devices, per the

and the PoE LED is OFF. No power is being sent out from the port.

ordering information Sec.1.2 for all the various P6K PoE modules option.

10/10 LK/AC 1

3 F/H POE

that is marked as LINK/ACT, as shown in the diagram.

2 1 3 5

properly for data traffic.

10/10 LK/AC

4 FULL/HALF

2 4 6 F/ H POE

traffic is not affected by PoE.

8 Port@ 10/100Mb Copper ports

6KP8-45RJ

LINK LK / ACT 2

port.

PoE

Show 9 more labels / short text on this page
support more RJ-45 · modules are totally · dependent upon the · powerful -48VDC · port require atleast · Pass-through PoE · 10/10 · PoE LEDs Summary · port
Page 59 of the GarrettCom 6K25e user manual — F/H
Page 59 · click to enlarge
Page 59

devices. The PoE LED is ON when the attached PD is drawing power from the

When non-PoE devices are connected, the PoE LED is OFF. Operation of Ethernet data

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED

through, so the 48VDC power source must be strong enough to provide power

to the 6K switch and to all the 8 RJ-45 ports with PD devices connected (up to

15 watts per PoE port). • In the case where the 48VDC power in not internally connected and no power

5.2.12 6KP8-45-2MT, 6@ 10/100Mbps RJ-45 and 2@100Mb multi-mode FX , MTRJ Small-Form-Factor

5.2.12a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor

  • For non-PoE devices connected, the PoE port will act as a normal RJ-45 port

100Mb MTRJ fiber ports. When installed in a Magnum 6K25e Switch, it supports the

is coming to the PoE ports for some reason, all the PoE port LEDs are ON

10/10 L 1

simultaneously to indicate a trouble condition. The ports will still operate

  • For PoE devices, each RJ-45 PoE port supports only 802.3af complaint
  • The PoE ports in Magnum 6K’s with 48VDC power input act as a pass-

3 2 4 6 LK

and the PoE LED is OFF. No power is being sent out from the port.

6 Port@10/10Mbps & 2 port @100Mb Multi-Mode Fiber port

4 FULL/HALF

F/H AC

standard distances as mentioned on 5.2.3. and the LEDs also act similarly.

ACT

F/H

ACT

F/H

LINK 2

6KP8V6KP8-45-2MT

ACTIVITY

that is marked as LINK/ACT, as shown in the diagram.

F/H

properly for data traffic.

45-2MT eight port Module is a

combo module with copper and

sizes of MTRJ connectors give

fiber ports on one module. The

6KP8-45-2MT is equipped with

six 10/100 RJ-45 ports and two

traffic is not affected by PoE.

an advantage of placing more

MTRJ type ports. The small

fiber (Small Form Factor)

port.

Show 4 more labels / short text on this page
10/100 · 10/100 · The Magnum 6KP8- · PoE LEDs Summary
Page 60 of the GarrettCom 6K25e user manual — F/H
Page 60 · click to enlarge
Page 60

550m at full duplex.

removing the transceiver, press the clips on either side of the transceiver at the same time

10/10 L 1

The Magnum GBIC-SXSC is a multi-mode Gigabit fiber connector

supports cable distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e.,

Each port has an Activity (ACT) LED indicating packets being received and a

supports cable distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e.,

6KP8V6 Port@ 10/100Mbps & 2 port @ 100Mbps

5.2.13 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector

10,25, 40 or 70Km at full duplex, and depend upon the Gigabit modules used.

3 2 4 6 LK

equipped with SC type connectors and can be easily snapped in and out. The Gigabit

fiber ports are most popular as server-to-switch and switch-to-switch applications. It

The GBIC transceiver is fastened using snap-in clips. Insert the transceiver

5.2.13a GBIC-LXSC & ZXSC Gigabit fiber (1000Mb), single-mode SC Connector

The Magnum GBIC-LXSC/ZXSC is a single-mode Gigabit fiber connector

equipped with SC type connectors and can be easily snapped in and out. The Gigabit

fiber ports are most popular as server-to-switch and switch-to-switch applications. It

(take care to insert it the right way up, arrows on top) until it clicks in space. While

4 FULL/HALF

When installed in a Magnum 6K25e Switch, it supports the standard distances as

Link (LK) LED indicating proper connectivity with the remote device when lit.

6KP8-45-2SLC

F/H AC

ACT

F/H

ACT

F/H

Single-Mode Fiber port (LC)

LINK 2

ACTIVITY

mentioned on 5.2.4. and the LEDs also act similarly.

F/H

fiber (Small Form Factor) LC type

give an advantage of placing more

The small size of LC connectors

10/100 RJ-45 ports and 2 Single-

combo module with copper and

ports on one module. The 6KP8-

45SLC eight port Module is a

45-2SLC is equipped with 6

and pull the transceiver out.

mode fiber ports.

fiber ports.

10/100 · 10/100 · The Magnum 6KP8-

Page 61 of the GarrettCom 6K25e user manual — 5.2.14 6KM-BLNK
Page 61 · click to enlarge
Page 61

suggestions listed below prior to contacting your supplier. However, if you are unsure of

3. Make sure that an AC power cord is properly attached to each Magnum 6K25e

Each port has an Activity (ACT) LED indicating packets being received and a link (LK)

Magnum 6K25e Switch is a straightforward procedure (see INSTALLATION, Section

intended to help locate, identify and correct these types of problems. Please follow the

1. If difficulty is encountered when installing or operating the unit, refer back to

Switch unit. Be certain that each AC power cord is plugged into a functioning

The 6KM-BLNK is a blank face plate or cover plate that must be installed in

performing as expected, do not attempt to repair the unit; instead contact your supplier

the Installation Section of the applicable chapter of this manual. Also check

electrical outlet. Use the PWR LEDs to verify each unit is receiving power.

to make sure that the various components of the network are interoperable.

consistently high performance in all network environments. The installation of a

Should problems develop during installation or operation, this section is

2. Check the cables and connectors to ensure that they have been properly

impaired during installation. (About 90% of network downtime can be

All Magnum Ethernet products are designed to provide reliability and

connected and the cables/wires have not been crimped or in some way

the procedures described in this section or if the Magnum 6K25e Switch is not

2.6); the operation is also straightforward and is discussed in Section 4.

LED indicating proper connectivity with the remote device when lit.

for assistance or contact GarrettCom Customer Support.

attributed to wiring and connector problems.)

6.1 Before Calling for Assistance

6.0 TROUBLESHOOTING

underneath the front panel hold

any empty 6K25e PM slot to

the 6KM-BLNK in place.

maintain proper cooling air

5.2.14 6KM-BLNK

flow, safety, etc.

Two screws

Page 62 of the GarrettCom 6K25e user manual — 6.2 When Calling for Assistance
Page 62 · click to enlarge
Page 62

known good device. Verify whether or not the problem is corrected. If not, go

All returns for repair must be accompanied by a Return Material Authorization

Switch product, it is recommended that the problem device be replaced with a

to Step 5 below. If the problem is corrected, the Magnum 6K25e Switch and

5. If the problem continues after completing Step 4 above, contact your supplier

of the Magnum 6K25e Switch unit or if unknown, contact GarrettCom, Inc.by

d. Any particular application that, when used, appears to create the problem;

4. A record of changes that have been made to your network configuration prior
4. If the problem is isolated to a network device other than the Magnum 6K25e
3. It is useful to include other network equipment models and related hardware,

including personal computers, workstations, terminals and printers; plus, the

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

number(s). Include the date(s) that you purchased the products from your

to the occurrence of the problem. Any changes to system administration

1. A complete description of the problem, including the following points:
2. An accurate list of GarrettCom product model(s) involved, with serial

fax, phone or email (support@garrettcom.com) for assistance.

Failure symptoms, including a full description of the problem.

6.3 Return Material Authorization (RMA) Procedure

(RMA) number. To obtain an RMA number, please use this URL -

Please be prepared to provide the following information.

Name and phone number of your contact person.

its associated cables are functioning properly.

Please have the following information readily available:

Packing List Number (or Sales Order Number)

c. The components involved in the problem;

procedures should all be noted in this record.

a. The nature and duration of the problem;

various network media types being used.

b. Situations when the problem occurs;

Name of your company / institution

Serial Number (or Invoice Number)

6.2 When Calling for Assistance

supplier.

Your shipping address · Date of installation · Product name

Page 63 of the GarrettCom 6K25e user manual — Attn.: Customer Service
Page 63 · click to enlarge
Page 63

sheet or bag for shipping protection. ( You may retain all connectors and this

1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic

material. This material may cause electro-static shock damage to the unit.

CAUTION : Do not pack the unit in Styrofoam "popcorn" type packing

GarrettCom will carefully test and evaluate all returned products, will repair products

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

GarrettCom, Inc. warrants its products to be free from defects in materials

that are under warranty at no charge, and will return the warranty-repaired units to

the sender with shipping charges prepaid (see Warranty Information, Appendix A,

units under warranty. Testing and repair of product that is not under warranty will

Should you need to ship the unit back to GarrettCom, please follow these

replace components in the products that prove to be defective at no charge other

product has been damaged by misuse, misapplication, or as a result of service or

GarrettCom reserves the right to charge for the testing of non-defective

This warranty will not be effective if, in the opinion of GarrettCom, the

Please complete the warranty card as this acts as a product registration,

and workmanship for a period of three (3) years from the date of shipment by

than shipping and handling, provided that the product is returned pre-paid to

inspecting any product returned for warranty repair which turns out not to be

for complete details). However, if the problem or condition causing the return

During this warranty period, GarrettCom will repair or, at its option,

3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to:

GarrettCom reserves the right to make a charge for handling and

cannot be duplicated by GarrettCom, the unit will be returned as:

and mail it to GarrettCom within two weeks of your purchase.

APPENDIX A: WARRANTY INFORMATION

6.4 Shipping and Packaging Information

No Problem Found.

47823 Westinghouse Dr.

Attn.: Customer Service

modification other than by GarrettCom.

GarrettCom, Inc.

result in a customer (user) charge.

Installation Guide.)

GarrettCom.

GarrettCom.

instructions:

faulty.

Fremont, CA 94539-7437

Page 64 of the GarrettCom 6K25e user manual — A+
Page 64 · click to enlarge
Page 64

connection, for example, will neither affect the Switch, its internal power supply, nor will

The manual power “On-Off” Switch (optional) is used for powering the unit on

The –48VDC solution is particularly useful in the telecommunication industry,

The -48VDC, 24VDC and 125VDC power options are designed using diodes

inside on each DC power input line behind the two external power connection terminals,

Magnum 6K25e Fiber Switches are easily installed in a variety of applications

where -48VDC, 24VDC and 125VDC power is used as the primary power source. The-

where it is common for facilities to operate on -48VDC power. Such companies include

B1.0 SPECIFICATIONS FOR MAGNUM 6K25E SWITCHES, DC POWER

regular and wireless telephone service providers, Internet Service Providers (ISPs) and

B2.0 -48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION

48VDC, 24VDC and 125VDC power configuration provides an Ethernet networking solution utilizing a special power supply in a managed Fiber Switch.

functions of Magnum 6K25e Switch -48VDC, 24VDC and 125VDC models are

GND GND CHASSIS

It protects the Switch from incorrect DC input connections. An incorrect polarity

With the exception of the power supply, all specifications and

FUSE +

Power ConsumptionSame as for AC models (see Section 1.1)
Power ConsumptionSame as for AC models (see Section 1.1)
Power ConsumptionSame as for AC models (see Section 1.1)

HUB POWER SWITCH

SUPPLY

Power Supply (Internal 125 VDC Option) Industrial Applications

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

Power Supply (Internal 24 VDC Option) Industrial Applications

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

B3.0 APPLICATIONS FOR DC POWERED SWITCHES

APPENDIX B : Internal DC Power Supply Options

and off when it is placed into or taken out of service.

Input Voltage88 - 150 VDC
Input Voltage36 - 70 VDC
Input Voltage20 - 36 VDC

identical to those listed in the main manual.

A+

A-

it blow the fuse in the internal power supply.

Power Supply (Internal -48VDC Option)

correctly applied to the two inputs.

so that the power from an external

source can only flow into the hub.

This allows the Switch to operate

only whenever DC power is

Page 65 of the GarrettCom 6K25e user manual — B4.0 INSTALLATION
Page 65 · click to enlarge
Page 65

other communication companies. In addition, many high availability equipment services,

facilities often use a battery backup system to maintain operations in the event of a power

environment, where it is common facilities to operate on 24VDC or 125VDC power. The

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage

The actual connection procedure is very straightforward. Simply connect the

An ON-OFF manual switch is optional for DC power. This can be used to cut

This section describes the installation of the -48 VDC, 24VDC and 125VDC

power source leads to the -48 VDC, 24VDC and 125VDC power terminal block on the

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

The 24VDC and 125VDC solution are particularly useful in the Industrial

125VDC solution is mainly used in power utilities, such as electrical substations, electrical generating plants, etc. The 24VDC applications are mainly in the Industrial

leads to the Magnum unit, beginning with ground. Ensure that each lead is securely

such as broadcasters, publishers, newspaper operations, brokerage firms and other

positive (+), Figure B4.0-48VDC Terminal Block on Magnum 6K25e-

failure. It is also frequently used for computer system backup, management and

environment, such as factory floor, HVAC equipment, military equipment, etc.

the user may elect to Ground either + or = terminal to suit the customer’s use.

_ + GND

36-70VDC

lead from 48V or –48V supply must be connected to the post labeled “+”.

off power connections and as a RESET for the Magnum 6K25e Switch.

OFF

ON

The leads are identified as negative (-),

Magnum 6K25es. (see figure at right).

In this picture, the -48VDC

terminal block on the Magnum 6K25e

is located on the rear of the unit and is

lead posts. It is similar for 24VDC and

125VDC options on Magnum 6K25e.

equipped with three (3) screw-down

48VDC and chassis ground (GND).

operations monitoring equipment.

B4.0 INSTALLATION

tightened.

Page 66 of the GarrettCom 6K25e user manual — B6.0 ORDERING INFORMATION
Page 66 · click to enlarge
Page 66
1. Minimum 18AWG cable for connection to a Centralized DC power source. 2. Minimum 14AWG cable for connection to a earthing wiring. 3. Use only with Listed 10 A circuit breaker provided in building installation. 4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.

To order the optional -48VDC power supply factory installed, add a suffix of “-

5. Fastening torque of the lugs on the terminal block: 9 inch-pound max. 6. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rac,k at least 4 inches apart, with the first one located
GNDTerminal for “earth” or ground wire connection to the hub chassis
GNDTerminal for “earth” or ground wire connection to the hub chassis
GNDTerminal for “earth” or ground wire connection to the hub chassis

Operation of Magnum 6K25e Switches with the optional -48VDC, 24VDC

-48VDC” after the product’s standard model # Example: Magnum 6K25eR-48VDC.

Similarly to order the optional 24VDC or 125VDC industrial specific power

DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”

supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s

and 125VDC power supply is identical to that of the standard AC-powered models.

standard model #. Example: Magnum 6K25e- 24VDC, Magnum 6K25e-125VDC.

Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-24V)

Power Supply (Internal, -48VDC Dual-Source, model # Dual-Src-48V)

Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)

C1.0 SPECIFICATIONS - FOR MAGNUM 6K25E FIBER SWITCH

InputTwo separate sources, each at 88 - 150 VDC

APPENDIX C: Internal DC Dual-Source Power Option

InputTwo separate sources, each at 36 - 70 VDC
InputTwo separate sources, each at 20 - 36 VDC

Please refer to Section 6.0 for troubleshooting

B4.1 UL Requirements for DC-powered units

within 6 inches of the terminal block.

B6.0 ORDERING INFORMATION

B7.0 TROUBLESHOOTING

B5.0 OPERATION

Page 67 of the GarrettCom 6K25e user manual — C5.0 INSTALLATION
Page 67 · click to enlarge
Page 67

24VDC and 125VDC models with this Dual-Source option are identical to those listed in the Magnum 6K25e Fiber Switches Installation and User Guide, including Appendix B

C2.0 MAGNUM 6K25E, with -48VDC, 24VDC and 125VDC Dual-Source option

d) Reverse polarity connections, if they should accidentally occur on either input, will not damage

125VDC Dual-Source Option units is identical to the standard AC-powered models. Refer to the main sections of this Installation and User Guide for a detailed description

a) The Switch unit can receive power from either input, “A” or “B”. The hub will normally draw

125VDC dual source leads to the -48VDC, 24VDC 7 125VDC power terminal block on the Magnum 6Ks Switch (shown in Figure )

The 6K25e-Switch models with the internal -48VDC, 24VDC and 125VDC

FUSE +

GND CHASSIS

b) The Switch unit will not allow power to flow from a higher voltage input to a lower voltage

c) When one correct DC input is present, the Switch will receive power if the other DC input is

the Switch or power supply internally (nor will it blow the fuse in the internal power supply)

e) The Switch will not receive power (and will not work) when both inputs are simultaneously

With the exception of the dual DC input power connections and the power

supply, all specifications and configuration options for the Magnum 6K25e -48VDC,

Dual-Source power supply are designed for installations where a battery plant is the

power source, and where two separate power sources are utilized in order to increase

SUPPLY A+

HUB

GND

can only flow into the unit. This allows the unit to operate whenever DC power is

because of the blocking action of the diodes. This is true even if one input connection is

This section describes the proper connection of the -48VDC, 24VDC and

The functionality of the Magnum 6K25e Switch -48VDC, 24VDC and

C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN

absent, or even if it is connected with reverse polarity or shorted or grounded.

C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION

its power from the DC source with the highest voltage at a given time.

input, i.e. the two DC power sources are not mixed together by the hub.

reversed while the Switch is operating from the other source.

correctly applied to either or both of the two inputs

operational uptime and to simplify maintenance.

B+

A-

B-

absent or are both incorrectly connected.

The Dual-Source DC power

option is designed using diodes inside

of the chassis on each DC power input

external power connection terminals)

so that power from an external source

“Internal DC Power Supply Option”

line. A diode is placed in each of the

of the Magnum 6K25e Switches.

four input lines (behind the four

C5.0 INSTALLATION

Page 68 of the GarrettCom 6K25e user manual — C6.0 ORDERING INFORMATION
Page 68 · click to enlarge
Page 68

positive(B+). The chassis “earth” or ground (GND) is a threaded post with a #6 nut. The

Terminal Block on a Magnum 48VDC with Dual-Source option

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage

1. Minimum 18 AWG cable for connection to a Centralized DC power source. 2. Minimum 14 AWG cable for connection to earthing wiring. 3. Use only with Listed 10 A circuit breaker provided in building installation. 4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.

Dual-Src-48V for the regular DS model with no ON-OFF switch

Figure C5.0-48VDC Dual-Source, wiring connections to the External

The connection procedure is straightforward. Simply connect the DC leads to

The 24VDC & 125VDC terminal block on Magnum 6K25e’s is similar to that

5. Fastening torque of the lugs on the terminal block: 9 inch pound max. 6. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground

(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely

Similarly, order the “Dual –source 24VDC” or “Dual-source 125VDC” as a

The -48VDC terminal block on the Magnum 6K25e Switch, as shown in Fig C5.0 is

The following must be adhered to in order to conform to UL requirements:

To order the optional Dual-Source -48VDC power supply factory installed,

order “Dual-Src48V” as a separate line item following the product model.

36-70VDC

or Dual-Src48V-SWITCH with the ON-OFF manual switch.

ExampleMagnum 6K25eR-24VDC or Magnum 6K25eR-125VDC

36-70VDC GND

the user may elect to Ground either + or = terminal to suit the customer’s use.

lead from 48V or –48V supply must be connected to the post labeled “+”.

A+ AB- B+

Dual Source terminal block for the 24VDC and 125VDC are similar.

separate line item following the product model.

ExampleMagnum 6K25eR-48VDC

within 6 inches of the terminal block.

described in the –48VDC information above.

C6.0 ORDERING INFORMATION

located on the right rear of the unit and

is located on the left rear. The primary

(A+), negative (A-), and the secondary

is equipped with five (5) screw-down

lead posts. If it is the reverse model it

terminals are identified as positive

power terminals as negative (B-),

C5.1 UL Requirements

tightened.

Page 69 of the GarrettCom 6K25e user manual — C7.0 OPERATION
Page 69 · click to enlarge
Page 69

Or Dual-Src125V-Switch for models with the ON-OFF switch

Operation of the Dual-Source Magnum 6Ks-48VDC, 24VDC and 125VDC

Dual-Src24V for regular models with no ON-OFF switch

Switch models are identical to that of the standard models.

C7.0 OPERATION

Ask about the GarrettCom 6K25e

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom 6K25e

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom 6K25e manual PDF

69 pages·1.3 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…