


Switching Hubs
Magnum 500-Series
213 Hammond Avenue Fremont, CA 94539
Phone (510) 438-9071

may be reproduced without prior written permission from Garrett Communications, Inc.
parts. Attempted service by unauthorized personnel shall render any and all
1998 Garrett Communications, Inc. All rights reserved. No part of this publication
Switching Hub, consult Section 5, Troubleshooting, of this User Guide.
warranties null and void. If problems are experienced with a Magnum
Personal Hub is a registered trademark of Garrett Communications, Inc.
Magnum 500-Series
Switching Hubs
UL is a registered trademark of Underwriters Laboratories
UL is a registered trademark of Underwriters Laboratories
Magnum is a trademark of Garrett Communications, Inc.
Ethernet is a trademark of Xerox Corporation
Printed in the United States of America.
Trademarks

This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to take whatever
Please use the following mailing address, phone and fax numbers or Internet address.
Radio Frequency Interference Statement
measures may be required to correct the interference.



10Mb series and 100Mb series, both with optional port modules Switching Hubs, unmanaged 500-Series and managed 5000-Series
100Mb RJ-45port + 10 / 100Mb combo port, or +FDX fiber port Workgroup Hubs
10Mb series and 100Mb series, both with optional port modules Personal Hubs , 100Mb
10Mb Mini-Transceivers and Coax Models, All Types 100Mb MII-TX and MII-FX models Aug. ‘98
8- and 4-port with up-link, 6-port with one switched 10/100Mb Personal Hubs, 10Mb series
8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series
Repeater Port Modules (RPMs), 6 types for Ethernet media
Bridge Port Modules (BPMs), 4 types, for segment isolation
All media combinations, incl. fiber ST, SC, mm., single mode
Garrett Communications offers the Magnum line of Ethernet LAN
physical layer connectivity products with industry-standard
functionality. Magnum products are available worldwide through
Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing
OEMs, integrators, representatives, and international distributors.
Stackable Concentrators, SNMP optional, 13-Ports
The “X-line” of configurable Mi X ed Media products:
Mini-Concentrators, 7 Ports, Repeaters, 2-Ports
MAGNUM
Local segmentation for all media types
2, 4 and 8 Port Models Transceivers, 10Mb and 100Mb series
Workgroup Bridges, 10Mb series
Fan-Outs, 10Mb series
Two-Port Switches

Full / Half duplex manual switch: Two switches, one for each 100Mb port
100BASE-TX (twisted pair): 100 m (328 ft) 100BASE-FX Fiber half-duplex: (multi-mode) 412 m (1350 ft) 100BASE-FX Fiber full-duplex: (multi-mode) 2.0 km (6,562 ft) 100BASE-FX Fiber half-duplex: (single-mode) 412 m (1350 ft) 100BASE-FX Fiber full-duplex: (single-mode) 15 km (49,215 ft)
(for Magnum 528 Fast Ethernet copper ports, normally use Cat 5 cable)
Aggregate Filtering Rate: 119,040 frames per second, 8 ports 297,600 frames per second, 2 TX ports (for Magnum 528 Fast Ethernet ports)
148,800 frames per second, 2 TX-pair (for Magnum 528 Fast Ethernet ports)
Data Rate: 10 Mbps and 100 Mbps Address Table Capacity: 2K (1954) node addresses Buffer Size : 1 MB Latency: 5 µs + packet time (100BASE-TX to 100BASE-T) 15 µs + packet time (10BASE-T to 10BASE-T, and 10BASE-T to 100 BASE-TX/FX)
(for Magnum 528 and 528F Fast Ethernet ports only)
Unshielded twisted pair - 100 m (328 ft)
Shielded twisted pair - 150 m (492 ft)
Maximum Standard Fast Ethernet Segment Lengths:
Maximum Ethernet Segment Lengths
Fiber Multi-mode Connector types:
Fiber Single-mode Connector types:
Connectors for copper wiring
1.1 Technical Specifications
Network Standards · Manual Switches · Performance

Max. Distance 15Km full-duplex (412m HDX, PDV limit)
Max. Distance 2Km full-duplex (412m HDX, PDV limit)
full-duplex, OFF for half-duplex). No AUTO for Model 528F Fiber ports
speed), 10 (ON for 10Mb/s speed), F/H (Full- or Half-Duplex, ON for
Dimensions: 9.55 in D x 8.5 in W x 1.3 in H (24 cm x 22cm x 3.3 cm)
AUTO (Auto-negotiation operation), per-port, 100 (ON for 100Mb/s
desktop, or vertical / wall mounting (brackets included)
Three years, return to factory Made in USA
Transmitter output power -11.5dBm -15.5dBm
Transmitter output power -16.5dBm -19.5dBm
Receiver sensitivity -23.5dBm -32.5dBm
100Mb/s Single-mode Port Optical Typical Worst
100Mb/s Multi-mode Port Optical Typical Worst
Receiver sensitivity -32dBm
PWR (AC power), LK/RX (per-port Link & Receive),
FDX (per-port full / half-duplex mode for 10Mb ports)
For Model 528 Fast Ethernet copper ports only:
Fiber Optic cable type 62.5/125µm multi-mode Saturation -14dBm
Fiber Optic cable type 9/125µm single-mode Saturation -8dBm
Emissions meet FCC Part 15 Class A
UL listed (UL1950), cUL, CE
LEDs:

Magnum 528 Switching Hub, eight ports at 10Mb F/H plus two 100Mb
node-capacity address table, Store and Forward operation
forwarding among all ports. Up-link switch on 10Mb port
the desired mode, or may optionally be set for support of
Magnum 528F-SC Same as Model 528, but with a 100BASE-FX fiber port,
Magnum 528F-ST Same as Model 528, but with a 100BASE-FX fiber port,
Magnum 528F-SMSC Same as Model 528, but with a 100BASE-FX fiber port,
Magnum 528F-SMST Same as Model 528, but with a 100BASE-FX fiber port,
Fast Ethernet ports (F/H and 10/100). Self-learning 2K
10/100 and F/H IEEE 802.3u standard auto-negotiation).
Magnum 508 Same as Model 528 but without the 2 Fast Ethernet ports
to filter all errored frames, full wire-speed filtering and
(The copper Fast Ethernet ports can be manually set to
single-mode SC connector, and a 100Mb RJ-45 port.
single-mode ST connector, and a 100Mb RJ-45 port.
Garrett Communications reserves the right to change specifications, performance
multi-mode SC connector, and a 100Mb RJ-45 port.
multi-mode ST connector, and a 100Mb RJ-45 port.
. Eight 10Mb switched ports (no 100Mb ports)
# 8. Internal auto-ranging power supply.
characteristics and/or model offerings without notice.
1.2 Ordering Information

delivery. Inspect the contents of this package for any signs of damage and ensure that the
product; notify the carrier of any damage which you believe occurred during shipment or
1 Installation and User Guide (this manual), and Product Registration Card
In the event there are items missing or damaged, contact the party from whom
The Magnum 500-Series Switching Hubs provide 8-port switching services to
enhance the performance of 10Mb Ethernet networks by segmenting the network traffic.
They may be used with existing Cat 3 cabling and shared 10b Ethernet hubs. On models
100Mb switching services for high speed network connections. Full speed is maintained
mode. The copper Fast Ethernet ports on Model 528 & 528F are normally set for 100Mb
Remove the items from the shipping container. Be sure to keep the shipping
warranty, please complete and return the enclosed Product Registration Card to Garrett
shipping container if possible. Refer to Section 5, Troubleshooting, for specific return
All 10Mb ports in both units can auto-negotiate to either half- or full-duplex
Examine the shipping container for obvious damage prior to installing this
container should you need to re-ship the unit at a later date. To validate the product
with manual selection of F/H duplex, but may be optionally set for auto-negotiation.
you purchased the product. If the unit needs to be returned, please use the original
528 and 528F, there are two Fast Ethernet switched ports additionally that provide
2.2 Product Description - Magnum 500-Series Switching Hubs
across all ports, even when handling the smallest 64-byte frames.
1 AC Power Cord (U.S. and other 115 VAC only)
1 Magnum 508, 528 or 528F Switching Hub
1 Set of two wall-mounting brackets
2.1 Inspecting the Package and Product
This package should contain:
Communications as soon as possible.
items listed below are included.
procedures.


use. Addresses of attached nodes are automatically learned and maintained, adapting the
switching services to network changes and expansions. The Magnum 500s provide high
ports for shielded and unshielded 10BASE-T connections. Magnum 528 switching hubs
negotiation (copper only) is internally selected, that operating speed is 10Mb or 100Mb,
two full/half (F/H) switches for the two 100Mb ports for manual selection of the full- or
Designed for use in departments with multiple workgroups, in remote offices
and in network traffic centers, the Magnum 500-Series switches are easy to install and
Magnum 500-Series switching hubs are equipped with eight shielded RJ-45
units include a up-link switch for crossover connection located next to 10Mb Port # 8.
Each 10Mb RJ-45 connector has two LED’s, one to indicate LK/RX (LINK / Receive)
On Magnum 528 and 528F models, the 100Mb activity LEDs and the LINK
and when the operating mode is full-duplex. Magnum 528 and 528F models also have
half-duplex mode when auto-negotiation is not selected. All connectors, switches and
LED’s are located on the front panel, with the AC power connector located at the rear.
also have two shielded RJ-45 Fast Ethernet ports for 100BASE-TX connection. Both
LEDs are located in the copper Fast Ethernet ports. Other LEDs indicate when auto-
activity and the other (FDX) for indicating full-duplex mode.
performance plug-and-play operation in a compact package.
2.2.1 Magnum 500-Series chassis
-- Magnum 508, 528 and
115-230V~ 50/60 Hz · 528F Switching Hub

The two Fast Ethernet switched ports on the Magnum 528 and 528F normally
performance. In this case, each of these two ports will run at 100Mbps at all times. The
user may select full- or half-duplex mode per-port with a manual switch for flexibility to
jumpers must be set. The “AUTO” LED will then be lit to show that auto-negotiation is
On Magnum 528 units, there are three LED’s for each Fast Ethernet port. One
when lit (possible when auto-negotiation is enabled only, copper ports), and one is lit to
indicate full-duplex operation (when it is OFF, operation is half-duplex). A twisted pair
or fiber cable must be connected to each 100Mb port and a proper link (LK lit) must be
All Magnum 500-Series Switching Hubs provide eight 10Mb switched ports.
All 10Mb switched ports are independently auto-negotiating for selecting to operate in
full-duplex mode, and will independently default to half-duplex mode when the 10Mb
are set (by factory default) to operate at fixed 100Mb speed for guaranteed high-speed
adapt to any type of Fast Ethernet devices. The Full / Half-duplex manual switches are
For operation in Fast Ethernet auto-negotiating mode (copper only), internal
indicates operation at 100Mb speed when lit, one indicates operation at 10Mb speed
made with the device at the other end of the cable in order for these LEDs to provide
2.2.2 10 and 100Mb ports, full- or half-duplex and auto-negotiation modes
1 2 3 4 5 6 7 8
device at the other end is half-duplex or is not an auto-negotiating device.
located on the front panel next to their corresponding Fast Ethernet ports.
1@100Mb fiber ports (528F models), and 8@10Mb ports
in operation. See Sections 4.4 and 3.4 for additional details.
RX
F/H
valid indications of operating conditions.
TX RX 100 Mb
L K RX
PWR
F/H
F/H F/H
LK/RX FDX
10Mb AUTO PWR · 100 100

On Magnum 528F units, there are three LED’s per Fiber Optic port. One (LK)
The two Fast Ethernet switched ports on the Magnum 528F normally are set (by factory
528F’s fiber ports can be connected using a multi-mode ST, SC or single-mode ST, SC
On the Magnum 528 and 528F models, the user may select full- or half-duplex
mode when ON (when it is OFF, operation is half-duplex), and one indicates Receiving
the correct CRC, i.e., are good packets. This eliminates the propagation of bad packets,
While other switching technologies such as "cut-through" or "express" impose
minimal frame latency, they will also permit bad frames to propagate out to the Ethernet
which are a result of late collisions, to be forwarded to add to the network traffic. Since
2.2.3 100Mb/s Fiber Port, ST or SC type (Single-Mode or Multi-Mode) 100Mb1@
default) to operate at fixed 100Mb speed for guaranteed high-speed performance. The
mode per-port with a manual switch for flexibility to adapt to any type of Fast Ethernet
devices. The Full/Half-duplex manual switches are located on the front panel under the
indicates ready for operation at 100Mb when lit, one indicates operation in full-duplex
packet) is loaded into the Magnum 500’s memory and inspected before forwarding can
occur. This technique ensures that all forwarded frames are of a valid length and have
Activity (RX). A fiber cable must be connected to each 100Mb port and a proper link
(LK lit) must be made with the device at the other end of the cable in order for these
segments connected. The "cut-through" technique permits collision fragment frames,
connector. In the factory-default setting, each of the 100Mb RJ-45 ports and/or the
The Magnum 500-Series are store-and-forward switches. Each frame (or
1 @ 100Mb Fiber port, type ST or SC (Magnum 528F models only)
ST Connector (Magnum 528F-ST) SC Connector (Magnum 528F-SC)
enabling all of the available bandwidth to be used for valid information.
F/H
LK
TX RX
F H
LEDs to provide valid indications of operating conditions.
100Mb Fiber port will run at 100Mb/s speed at all times
corresponding Fast Ethernet ports for convenient access.
F/H
2.2.3 Frame Buffering and Latency
RX
F/H
TX RX
F H F H
L K RX
PWR
F/H
100 M b · 100 M b

there is no way to filter frames with a bad CRC (the entire frame must be present in order
likely when traffic is heavy, the result of the Magnum 500’s Store and Forward operation
For 10Mb-to-10Mb or 10Mb-to-100Mb or 100Mb-to-10Mb forwarding, the latency is 15
for CRC to be calculated), the result of indiscriminate cut-through forwarding is greater
traffic congestion, especially at peak activity. Since collisions and bad packets are more
(Many other switching hubs have their packet buffer storage space divided evenly across
port buffer fills up, dropped packets result.) This dynamic buffer allocation provides the
capability for the maximum resources of the Magnum 500 unit to be applied to all traffic
based flow-control mechanism. When the switch detects that its free buffer queue space
forwarded to its destination) of the 500-Series switches varies with the port-speed types,
and the length of the frame is a variable here as it is with all store-and-forward switches.
all ports, resulting in a small, fixed number of packets to be stored per port. When the
loads, even when the traffic activity is unbalanced across the ports. Since the traffic on
an operating network is constantly varying in packet density per port and in aggregate
Another feature implemented in Magnum 500-series switches is a collision-
The latency (the time the frame spends in the switch before it is sent along or
is that more bandwidth is available for good packets when the traffic load is greatest.
Magnum 500-Series dynamically allocates buffer space from a 1 MB memory pool,
microseconds plus the packet time at 10Mb. For 100Mb-to-100Mb forwarding, the
To minimize the possibility of dropping frames on congested ports, the
ensuring that heavily used ports receive very large buffer space for packet storage.
is low, the switch prevents more frames from entering by forcing a collision on all
density, the Magnum 500 Switches are constantly adapting internally to provide
receiving half-duplex ports in order to stop incoming traffic. See Section 4.6 for
maximum network performance with the least dropped packets.
latency is 5 microseconds plus the packet time at 100Mb.
additional details.

The Magnum 508 has eight 10Mb switched ports, each operating at full-or
The two 100Mb ports normally are set to operate at 100Mb speed, and are
verify wiring connections at both ends of each attached twisted-pair cable.
All 10Mb and 100Mb RJ-45 ports are capable of half- or full-duplex. The
bandwidth networks, performing high speed filter/forward operations on
the traffic, giving each port’s segment a full 10Mb or 100Mb bandwidth.
matter what types of devices are attached. (Auto-negotiation is optional).
large networks. Front-mounted LINK LEDs provide a very simple way to
Front-mounted LEDs show the operating mode and activity on each port.
The compact package of the Magnum 500-Series switches allow them to
Magnum 500’s are self-learning for up to 8000 node addresses, so they
half-duplex, for segmenting a 10Mb network to increase performance.
segments for distances up to 2Km multi-mode or 15Km single-mode.
Magnum 500-Series Switching Hubs overcome congestion on shared-
user selected for full-or half-duplex. The 100Mb speed is assured, no
performance even for unbalanced loads. And, flow control is included.
can be placed in operation without complex set-up procedures, even in
Magnum 500-Series Switching Hub to be used throughout the world.
Front panel LED’s display the status of each port for easy monitoring.
! Ideal for enhancing the performance of existing 10Mb segments
Magnum 500-Series Switching Hubs adapt to their network’s traffic
be used in office networks where a large rack-mount unit would be
undesirable. An internal auto-ranging AC power supply allows any
Magnum 528F’s 100Mb fiber port may be used in full-duplex fiber
! Small package for office networks, "Universal" Power Supply
changes, dynamically allocating internal resources to maximize
! Plug-and-Play installation for high performance switching
! Assured 100Mb performance in any network set-up
! Full-duplex or Half-duplex operation, auto-sensing
! Front-mounted LEDs display operating status
! Dynamic Buffer Space Allocation
2.3 Features and Benefits
! High Performance


In a typical 10Mb network performance upgrade, multiple cascaded 10Mb hubs
connects all 10Mb equipment, hubs and servers, in the existing network while providing
forwarded to go outside to the appropriate other segments. This provides several 10Mb
Personal Hubs with users attached, and provides dedicated 10Mb ports for commonly
flexibility, and are easily used in a variety of ways including client/server applications,
traffic domains rather than only one as before, greatly increasing performance. This is
Magnum 500-Series Switching Hubs offer a great deal of performance and
The Magnum 508 switch filters and forwards packets from one segment to
RX PW R COL 1 2 3 5 6 7
RX PWR COL
departmental networks performance upgrades and collapsed backbone applications.
Switching Hub provides eight 10Mb traffic domains for increased performance. It
another, containing the local traffic and allowing only the packets which need to be
1 2 3 5 6 7
connect all networked devices using one 10Mb traffic domain. The Magnum 508
ideal for a central departmental switch that has branches out to workgroup and/or
Ma gnum 80 0E
Work gr oup Hub
RX
full 10Mb bandwidth to the network segment on each separate port.
1 2 3 4 5 6 7 8
RX PW R COL 1 2 3 5 6 7
RX PWR COL 1 2 3 5 6 7
used servers. Figure 2.4 illustrates this example.
PWR
Ma gnum 80 0E
Work gr oup Hub
10Mbps bandwidth on each segment.
2.4 Applications

may be attached to one of the Magnum 528’s Fast Ethernet port (see illustration in Figure
Ethernet RJ-45 ports. The applications may be similar to the Magnum 508 but, but with
existing 10Mb network. The servers had installed 10/100 network interface (NIC) cards
and, as one application alternative, they may be connected to the Magnum 528’s 100Mb
To accommodate this while maintaining the rest of the network topology, a 100Mb hub
example, a Magnum Lite ML8 100Mb office hub) then provides 100Mb ports for the
In this example, the 10Mb segments on the 528’s 10Mb ports each have 10Mb
of switched bandwidth, and may be either half- or full-duplex per port. Simultaneously,
where it needed to make a decision about adding some 100Mb servers and users to the
As the network expands further, some users may need to go to 100Mb speed.
The Magnum 528 Switching Hub provides complete network connectivity so
that all 10Mb and 100Mb nodes operate in a unified manner, functioning as one plug-
Consider Figure 2.4c. In this example, a small corporation reached a point
The Magnum 528 Switching Hub is a Magnum 508 plus two 100Mb Fast
two 100Mb copper ports, it also provides switched connectivity between 10Mb and
2.4c below, showing only one server per 100Mb port). The Fast Ethernet hub (for
the two Fast Ethernet ports provide 100Mb F/H each, and have full-speed switched
ports to provide much better 100Mb server access speed for all the 10Mb users.
RX PWR COL 1 2 3 4 5 6 7 8
10 0 Mb/s GARRETT
100Mb Servers 10Mb Workgroup
1 2 3 4 5 6 7 8
to an existing 10Mb network
access to each other as well as to each of the 10Mb ports.
10Mb LINK AUTO PWR
servers and for some 100Mb users.
and-play switched network facility.
100Mb network segments.

10/100 speed auto-negotiation, it is necessary in this situation to operate both ends of the
mode. The result is similar to “stacking” the two Magnum 528s to provide a net total 16
fiber link with ports that have fixed 100Mb-speed capability. In addition, since 100Mb
fiber cable has severe distance limitations at half-duplex, it is almost always necessary to
only have auto-negotiation on their 100Mb ports cannot support this application, but the
Figure 2.4d: The Magnum 528 provides 100Mb ports for backbone connections.
In another situation similar to Example 2 above, the network may need to be
using one 100Mb switched port for local high speed servers and users, while using the
Using two Magnum 528s and linking a 100Mb switched port from each unit,
When using a Magnum 528’s 100Mb switched port as a link, it is frequently
desirable to make the connection to the upstream device using fiber cable operating at
linked to a Fast Ethernet backbone. This application is handled by the Magnum 528
one can implement a Fast Ethernet switched connection which can run in full duplex
100Mb speed. In this situation, an external 100Mb Media Converter unit (such as a
operate such a fiber link in the full-duplex mode. Many low-end switching hubs that
Because commercially-available 100Mb Media Converters do not support
Magnum 528 . . . with fixed 100Mb speed as a default setting, and with manually-
selected half- or full-duplex mode per Fast Ethernet port . . . handles this readily.
Magnum 15E) is used to change from twisted pair cable to fiber cable.
RX PWR COL 1 2 3 5 6 7
ports of switched 10Mb plus 2 ports of switched 100Mb.
UPLINK
RX
1 2 3 4 5 6 7 8
other 100Mb switched port for a link upstream.
10Mb LINK AUTO PWR
100Mb Fiber Link 100Mb Media Converter
1 2 3 4 5 6 7 8

high-speed LAN connection upstream with switched 100Mb full-duplex performance and
frequently desirable to operate the connection to the upstream device in full-duplex mode
since 100Mb fiber cable has severe distance limitations at half-duplex. In this situation, it
is necessary to operate both ends of the fiber link with ports that have fixed 100Mb-speed
auto-negotiation cannot support this application. They have no built-in fiber, and they do
linked with fiber cabling to a Fast Ethernet backbone. This application is handled by the
Magnum 528F, using one 100Mb switched copper port for local high speed servers and
converters properly, the converters are awkward extra items that add substantially to the
In another situation similar to Example 3 above, the network may need to be
Using the Magnum 528F’s 100Mb switched fiber port, one can implement a
Many low-end “commodity” switching hubs that only have RJ-45 ports with
cost. But the Magnum 528F models . . . with fixed 100Mb speed as a default setting on
the Fast Ethernet ports, and with manually-selected half- or full-duplex mode per Fast
Figure 2.4e: The Magnum 528F provides a 100Mb port for backbone connection.
users, while using the fiber 100Mb switched port for the fiber backbone connection.
Fast Ethernet switched fiber connection that runs in full-duplex mode. The result is a
maximum fiber distance – all without a 100Mb media converter. Alternatively, two
Magnum 528Fs can be connected with switched 100Mb fiber to form a larger LAN.
When using a Magnum 528F’s 100Mb switched fiber port as a link, it is
not properly support 100Mb media converters. Even if they did support media
Ethernet port . . . handle this application readily and economically.
and user-determined full-duplex capability (no auto-negotiation).
RX PWR COL
UPLINK
1 2 3 4 5 6 7 8 100Mb Fiber Link
LINK
Magnum 500-series Switching Hub
1 2 3 4 5 6 7 8
TX RX 100 Mb
F/H
1 2 3 4 5 6 7 8

compact size of the unit allows it to be conveniently placed in an office or lab area, and it
from accidental damage in a lab or workplace setting. Maintain an open view of the front
This chapter provides instructions for installing Magnum 500-Series switches.
layout of the network. Typically the switch is placed where combinations of 10Mb and
can occur from the small fan in the bottom-rear while the unit is in operation. See figure
Magnum 500 site. The rugged metal case of the Magnum 500 will normally protect it
to visually monitor the status LEDs. Keep an open area around the unit so that cooling
The Magnum 500-Series switch can be easily mounted on a table-top or any
The location of a Magnum 500-Series switch is dependent on the physical
100Mb network devices need to be connected to communicate with each other. The
Locate an AC receptacle that is within six feet (2 meters) of the intended
scratching finished surfaces. When stacked, the rubber feet also provide separation
can also be either shelf of wall-mounted (see instructions in 3.1.2 below). Wall-
suitable horizontal surface, and has four rubber feet to provide stability without
mounting brackets are included, usable for single units (but not for stacks).
between units for the exhaust of the rear cooling fan.
3.1 Locating Magnum 500-Series switches
3.1.1 Table-Top or Shelf Mounting
below.
115-230V~ 50/60 Hz

(and screws) to allow the unit to be mounted in nearly any desired orientation or position.
Each Magnum 500-Series switch is shipped with two metal mounting brackets
bracket, and attached to the Magnum 500 through the round hole of the bracket. A user-
supplied screw attaches the bracket to the mounting surface. It is recommended that the
500-Series Hubs. When horizontal placement is not possible or desirable (such as on the
The E-Stand also allows the Magnum 500-Series unit to be securely mounted
The brackets are attached to the metal hub case using one of the metal screws for each
attached, the brackets will extend slightly below the base of the unit to allow clearance
floor in carpeted areas), the E-Stand offers a unique space management option. Simply
The optional E-Stand provides a vertical mounting option for the Magnum
mounting brackets be attached to two opposite corners of the unit. When properly
TO
X 1 0 0 1 0
F/
H
align the rectangular cut-out on the E-Stand with the air vent on either side of the
R LK/RX F
D
Proper mounting
via two screws that connect through the E-Stand and into the side of the unit.
for the rubber feet and for cooling fan exhaust space.
3.1.2 Wall (or Vertical Surface) Mounting
See Figure 3.1.3, following.
3.1.3 Optional E-Stand
Magnum 500 unit.
GARRETT 100 Mb/s · Magnum 500-series · Switching Hub


environments where the AC voltage is from 90 to 260 volts with a power input frequency
supply, and have a recessed male IEC connector for the AC power cord at the right-rear.
Magnum 500-Series Switching Hubs incorporate an internal universal power
between 47 and 63 Hz. The unit will consume just under 10 watts of power typically.
When connecting the Ethernet cabling, there is no need to power down the
unit. Individual segments can be connected or disconnected without concern for AC
A six-foot 115 VAC 60 Hz standard power cord is supplied with each unit shipped
The Magnum 500’s auto-ranging power supply supports installation
3.2 Powering the Magnum 500-Series Switch
power-related problems or damage to the unit.
within the United States and Canada.
115-230V~ 50/60 Hz


ports). CAT 5 cables should be used when making 100BASE-TX connections. When the
The following procedure describes how to connect a 10BASE-T or 100BASE-TX
ports are used as 10BASE-T ports, CAT 3 may alternatively be used. In either case, the
3.3.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded)
switch. If this does not help, ensure that the cable is connected properly and that
The Magnum 500-Series Switching Hubs can be connected to the following
twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded
Port # 8, if the LINK LED is not illuminated, change the setting of the up-link
and 100Mb) be used whenever possible in order to provide flexibility in a
100BASE-TX connections (Magnum 528 only) 10BASE-T connections
Media IEEE Standard Connector
shielded, either unshielded or shielded cables and wiring may be used.
maximum distance for unshielded twisted pair cabling is 100 meters (328 ft).
Twisted Pair (CAT 3) 10BASE-T RJ-45
Twisted Pair (CAT 5) 100BASE-TX RJ-45
the device on the other end is powered and is not defective.
mixed-speed network, including both 10 and 100Mb/s.
3.3 Connecting Ethernet Media
and shielded twisted pair cables.
LK/RX FDX
F/H 1 2
PWR
100 100

The following procedure applies to 100BASE-FX applications using the Magnum
3.4 Internal jumper settings, 100Mb RJ-45 ports, auto-negotiation ON or OFF
certain, regardless of whether the attached device does or does not properly support auto-
internal switches and jumper settings that allow these choices to be made, as described in
The factory (or default) setting is for fixed 100Mb speed (no auto-negotiation)
In some applications, it may be desired to use standard auto-negotiation and/or
to configure the first 100Mb copper port for up-link. For trained technicians, there are
528F Switching Hub with ST-type (twist-lock) and SC-type (snap-in) fiber connectors.
so that the speed and mode of the Model 528’s copper Fast Ethernet ports’ operation is
negotiation. This is desirable when there are unknown devices presently or potentially
(TX) port of the remote device. Use the non-color coded fiber strand for this.
when power is ON in the unit). If LINK is not lit after cable connection, the
normal cause is improper cable polarity. Swap the fiber cables on the 528F’s
connected, which may or may not operate correctly at all times with auto-negotiation.
to the Receive (RX) port of the remote device. Begin with the color-coded
tissue dampened in alcohol. Make certain the connectors are clean before
bands at regular intervals; you must use the color-coded strand on
strand of the cable for this first “Transmit-to-Receive” connection.
RX
F/H
fiber connectors (either ST or SC type) to remedy this situation.
TX RX 100 Mb PWR
100BASE-TX connections (Magnum 528F only)
the associated ports at each end of the fiber optic segment.
3.3.2 Connecting Fiber Optic 100BASE-FX, Type ST and SC
F H
PWR
F/H
AUT O
L K
RX
F/H
T X RX 100 Mb
L K RX
F/H
connecting.


continue to operate correctly indefinitely. Attached devices can and do change while the
Therefore, the default setting of fixed 100Mb speed with F/H manual selection
converters, which do not support auto-negotiation) in the cabling between the switched
maximum-performance condition for the Model 528’s Fast Ethernet high speed ports.
See Section 4.4 for additional information on auto-negotiation functionality.
This chapter describes the functions and operation of the Magnum 508, 528
network is operating. In addition, there may be intermediate devices (such as media
port and the rest of the network, requiring the switching port to be fixed in speed and
Switch Port Function Default setting Manual setting
negotiating network running properly once is not enough to make certain that it will
Figure 3.5. Be certain that the main power is off before opening the unit or
Jumper Port Function Position 1 - 2 Position 2 - 3
(no auto-negotiation, copper ports) is generally desirable because it is a safe and a
SW7 Port 1 Uplink Uplink = Uplink X
network operation at any time, whether intended or accidental. Getting an auto-
SW2 Both 100Mb Auto-negotiation 100 Mb (Non-Auto) AUTO
JP4 Port 1 10 / 100 config 100 Mb (default) 10 Mb JP3 Port 2 10 / 100 config 100 Mb (default) 10 Mb
mode in order to achieve and maintain the desired overall network operation.
SW7 JP3
changing any internal settings.
and 528F Switching Hubs.
When Non-Auto:

The Magnum Model 508 provides switched connectivity at Ethernet wire-speed
configuration settings are user options for UP-LINK on 10Mb port #8, and the Half / Full
Each time a packet arrives on one of the switched ports, the decision is taken to
either filter or to forward the packet. Packets whose source and destination addresses are
on the same port segment will be filtered, constraining them to one port and relieving the
another port segment will be forwarded to the appropriate port, and will not be sent to the
added or removed or moved from one segment to another, the 500s automatically keep up
bandwidth utilization and network performance. All ports can talk to all other ports in a
duplex mode selection for the 100Mb ports of the Magnum 528 and 528F. The internal
All Magnum 500-Series units have large address table capacity of 1.9K node
addresses, suitable for use in large networks They are self-learning, so that as nodes are
Magnum 500-Series port is a separate traffic domain, and all ports operate to maximize
Magnum 500, but local traffic on a port will not consume any of the bandwidth on any
other ports where it is not needed. Traffic needed for maintaining the operation of the
connect eight 10Mb and two 100Mb segments for unified access at wire speed. Each
Magnum 500-Series units are plug-and-play devices. There is no software
rest of the network from processing them. A packet whose destination address is on
The Magnum 500-Series Switching Hubs operate in the store-and-forward
among all of its eight 10Mb ports. The Magnum Model 528 and 528F switch inter-
switching mode, which eliminates bad packets and enables peak performance to be
configuring to be done at installation or for maintenance. The only hardware
network (such as occasional multi-cast packets) are forwarded to all ports.
with node locations. To reset the address buffer, cycle power down-and-up.
achieved when there is heavy traffic on the network.
functions of both are described below.
4.1 Switching Functionality
other port.
Filtering and Forwarding · Address Learning

10Mb speed). 10 LED : One for each “100Mb” port, ON when the copper port speed is 10Mb/s. 100 LED : One for each “100Mb” port, ON when the port speed is 100Mb/s. F/H : Full / Half duplex LED, one for each 100Mb port, ON when the
LED status, which is illuminated when a proper link is made. (Note: for optional up-link
their speed is internally fixed at 100Mb (no auto-negotiation, no
4.3 Manual switches for 10Mb Up-link, and Fast Ethernet Full / Half Duplex
The unit has a manual Up-link switch, located on the front panel next to 10Mb
node (= position) or to be cascaded (X position) to a another 10Mb repeater or switching
The two F/H switches are located next to each Fast Ethernet port on Magnum
configured to operate in the auto-negotiation mode, OFF when
Port # 8 which it controls. It enables the port’s cable to either connect to a user station
auto-negotiated to operate Full Duplex, OFF for half duplex.
F/H Switch (Magnum 528 only)
hub in the network. Verify proper Up-link switch position by noting Port 8’s LK/RX
100Mb speed (no auto-negotiation), manual selection of half or full duplex at 100Mb
528’s. When the two Fast Ethernet ports of a Model 528 are set to operate at fixed
PWR : Power LED, ON when AC power is applied to the unit.
F/H F/H
port is running full duplex, OFF for half duplex.
setting on 100Mb copper port #1 via an internal switch, see Section 3.4)
when the port has Receive activity.
For Magnum 528 and 528F models only :
ST Connector (Magnum 528F only)

For all Magnum 500-series models :
4.2 Status LEDs
100 100 · Up-link Switch

has no effect. The adjacent F/H LED will indicate the full- or half-duplex operating status
standard. The selection is made via an internal jumper (see Section 3.4 for jumper-setting
One frequently-used application for the Magnum 528’s Fast Ethernet ports is to
backbone, or some other remote 100Mb device. In this case, it is desirable to operate the
imagined) changes in the network. The “10” and “100” LEDs will indicate the operating
may be made for each port separately. If the Magnum 528’s Fast Ethernet copper ports
are internally set for auto-negotiation (AUTO LED is ON), then the F/H switch selection
either fixed 100Mb speed or for 10/100 speed F/H auto-negotiation per the IEEE802.3u
At 100Mb-fixed speed, the user may select half- or full-duplex mode manually
capabilities of the remote device. Standard commercially-available Fast Ethernet media
When the Fast Ethernet copper ports are set in the auto-negotiation mode, the
F/H manual switches have no effect. The AUTO LED will be ON. The operating speed
and connected to an another auto-negotiating device, there are 4 different speed and F/H
The Magnum 528 Switching Hub’s Fast Ethernet copper ports can be set for
located on the front panel next to their corresponding ports. See Section 4.3 above for
converters do not support auto-negotiation, and require that the switched port to which
When Magnum 528’s Fast Ethernet copper ports are set for auto-negotiation
modes selectable depending on what the other device supports. These are: (1) 100Mb
on each Fast Ethernet port separately. The two Full/Half duplex manual switches are
they are connected be at 100Mb fixed speed. Attachment to 10/100 auto-negotiation
full-duplex, (2) 100Mb half-duplex, (3) 10Mb full-duplex and (4) 10Mb half-duplex.
fiber link at 100Mb speed, and at either half- or full duplex mode depending on the
ports will not work properly. The Magnum 528’s Fast Ethernet ports handle this
connect one of them using fiber cabling to another switching hub in the network
and F/H mode of the high speed ports can change at any time to adapt to (real or
4.4 Auto-negotiation option for Fast Ethernet copper ports
instructions ). The factory default setting is for fixed 100Mb speed.
of the port as determined by the internal auto-negotiation logic.
situation easily in the default setting..
F/H manual switch description.
speed.

must account for all devices and cable lengths within that domain. For Magnum 528 Fast
The auto-negotiation logic will attempt to operate in descending order and will normally
mode” result can change at any time depending on network changes that may occur). If
arrive at the highest order mode that both devices can support at that time. (Since auto-
they are in is powered up. These are exceptions to the “negotiate at LINK –
When operating in 100Mb half-duplex mode, cable distances and hop-counts
network topology must be a “star” type, not a “bus” type. With full-duplex mode, the
negotiation is potentially an externally-controlled process, the original “highest order
the device at the other end is not an auto-negotiating device, the Magnum 528’s Fast
Ethernet ports will try to detect its idle signal to determine 10 or 100 speed, and will
Auto-negotiation per-port for 802.3u-compliant switches occurs when:
may be limited within that collision domain. The Path Delay Values (PDV) bit-times
Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.
Full-duplex Ethernet provides separate Transmit and Receive data paths,
enabling simultaneous bi-directional collision-free data movements on a port. The
-- when the second of the two connected devices is powered up*, i.e.,
the devices at both ends of the cable are capable of operation at either
-- when LINK is re-established on a port after being lost temporarily.
10Mb or 100Mb speed and/or in full- or half-duplex mode, and can
4.5 Auto-negotiation for 10Mb ports, half- or full-duplex mode
enabled” rule above, but may be occasionally encountered.
send/receive auto-negotiation pulses, and . . .
when LINK is established for a port, or
default to half duplex.
General information -

to operate as full-duplex, the Magnum 500’s 10Mb port will negotiate to run full-duplex.
If the attached device or node doesn’t support F/H mode auto-negotiation (for example, if
difference makes the 10Mb port unable to keep up. It can also occur when multiple 10Mb
The switch is constantly monitoring the size of the internal free-buffer queue. It
on the other end of a port’s attached cable supports F/H mode auto-negotiation or is set
cabling, an external 10Mb fiber Media Converter unit can be used to convert the cable to
single-mode fiber, either half- or full-duplex. (At 100Mb speed, fiber cable can achieve
mechanism. The purpose of flow-control is to reduce the risk of data loss if a long burst
device by forcing a collision indication on all half-duplex ports (except for the ports on
which the switch is transmitting). When the switch has transmitted some of the backlog
forced collisions cease, and frames can again enter the switch. (The 256 buffer threshold
ensures that all ports can receive and complete a maximum-length frame that may be in
The Magnum 500-Series Switching Hubs perform half- or full-duplex mode
auto-negotiation independently on all eight 10Mb switched ports. If the device or node
If needed to extend to a greater distance than the 100 meters available with twisted pair
of activity causes the switch to backlog frames until its memory is fill up. This is most
likely to occur when data is moving from a 100Mb port to a 10Mb port, and the speed
ports are attempting to transmit to one 10Mb port, and in other protracted heavy traffic
detects that it is becoming congested when there are fewer than 256 buffers on the free
fiber. Fiber cable at 10Mb can run up to 2Km with multi-mode fiber and 15Km with
queue(out of 1M capacity). At that time, the switch prevents frames from entering the
from its buffer, and the available free-buffer queue increases to more than256 spaces,
cable distance is only limited by the physical layer line driver and cable attenuation.
it is a 10Mb repeater or a standard 10Mb hub), the Magnum 500’s 10Mb ports will
Magnum 500 series switches incorporate a collision-based flow-control
There are no collision-domain restrictions or limitations.
these distances only in the full-duplex mode).
4.6 Collision-based Flow-control
default to operate at half-duplex.
situations.
process.

suggestions listed below prior to contacting your supplier. However, if you are unsure of
known good device. Verify whether or not the problem is corrected. If not, go
consistently high performance in all network environments. The installation of Magnum
the procedures described in this section or if the Magnum 508 product is not performing
as expected, do not attempt to repair the unit; instead contact your supplier for assistance
Series product, it is recommended that the problem device be replaced with a
intended to help locate, identify and correct these types of problems. Please follow the
the Installation Section of the applicable chapter of this manual. Also check
508 Switching Hubs is a straightforward procedure (see Sections 3); the operation is
to make sure that the various components of the network are inter-operable.
Should problems develop during installation or operation, this section is
connected and the cables/wires have not been crimped or in some way
impaired during installation. (About 90% of network downtime can be
500-Series unit. Be certain that each AC power cord is plugged into a
functioning electrical outlet. Use the PWR LEDs to verify each unit is
All Magnum Ethernet products are designed to provide reliability and
to Step 5 below. If the problem is corrected, the Magnum 500-Series
of the Magnum 500-Series unit (or if unknown, contact Garrett
Switching Hub and its associated cables are functioning properly.
Communications) by fax, phone or email for assistance.
or contact Garrett Communications Customer Support.
attributed to wiring and connector problems.)
also straightforward and is discussed in Sections 4.
5.1 Before Calling for Assistance
receiving power.

email to support@garrettcom.com. When calling, please have the following information
Garrett Communications will carefully test and evaluate all returned product. If
including personal computers, workstations, terminals and printers; plus, the
All returns for repair must be accompanied by a Return Material Authorization
(RMA) number. To obtain an RMA number, contact Garrett Communications Customer
defective units under warranty. Testing and repair of product that is not under warranty
d. Any particular application that, when used, appears to create the problem;
serial number(s). Include the date(s) that you purchased the products from
Support at (510) 438-9071 (office hours: 8AM - 5PM Pacific Standard Time) or send
Garrett Communications reserves the right to charge for the testing of non-
to the occurrence of the problem. Any changes to system administration
Failure symptoms, including a description of the specific problem
the problem or condition cannot be duplicated, the unit will be returned as:
5.3 Return Material Authorization (RMA) Procedure
Please be prepared to provide the following information.
Name and phone number of your contact person.
Packing List Number (or Sales Order Number)
c. The components involved in the problem;
procedures should all be noted in this record.
a. The nature and duration of the problem;
b. Situations when the problem occurs;
various network media types being used.
Serial Number (or Invoice Number)
No Problem Found.
5.2 When Calling for Assistance
your supplier.
will be charged for.
readily available:

materials and workmanship for a period of three (3) years from the date of shipment by
sheet or bag for shipping protection. ( You may retain all connectors and this
Garrett Communications reserves the right to make a charge for handling and
inspecting any product returned for warranty repair which turns out not to be faulty.
container if available. Units should be wrapped in a "bubble-wrap" plastic
Do not pack the unit in Styrofoam "popcorn" type packing material. This
option, replace components in the products that prove to be defective at no charge
other than shipping and handling, provided that the product is returned pre-paid to
Communications, the product has been damaged by misuse, misapplication, or as a
Please complete the warranty card as this acts as a product registration, and
Should you need to ship the unit back to Garrett Communications, please
During this warranty period, Garrett Communications will repair or, at its
Garrett Communications warrants its products to be free from defects in
material may cause electro-static shock damage to the unit.
result of service or modification other than by Garrett Communications.
This warranty will not be effective if, in the opinion of Garrett
mail it to Garrett Communications within two weeks of your purchase.
5.4 Shipping and Packaging Information
Attn.: Customer Service
outside of the shipping container.
Installation Guide.)
Garrett Communications.
Garrett Communications.
follow these instructions:
charges.
Garrett Communications · 213 Hammond Avenue · Fremont, CA 94539

With the exception of the power supply, all specifications for the Magnum 500-
48VDC power configuration provides an Ethernet networking solution utilizing a special
computer system back up, management computers and operations monitoring equipment.
The internal 48VDC power supply models are designed for installations where
a battery plant is the power source. The operational range for the 48 VDC power supply
Magnum 508-48VDC and 528-48VDC Switching Hubs are easily installed in
a variety of applications where 48 VDC power is used as the primary power source. The
VDC power. Such companies include regular and wireless telephone service providers,
Internet service providers (ISPs) and other communications companies , as well as high-
availability equipment serving broadcasters, publishers, and some financial institutions.
In addition, many large newspaper operations, brokerage firms and other facilities often
battery-powered plant. It is frequently used to provide an Ethernet LAN connection for
power supply in hubs with a proven track record. The solution is particularly useful in
use a battery backup system to maintain operations in the event of a power failure, and
B1.0 SPECIFICATIONS - MAGNUM 508, 528 and 528F 48VDC OPTION
The functionality of the Magnum 500-series with 48VDC power options is
the telecommunication industry, where it is common for equipment to operate on -48
even long term outages. The 508/528-48VDC is ideal for utility use in this type of
is 36 - 72 VDC. Each unit is normally convection-cooled for silent operation.
series with 48VDC power options are identical to those listed in Section 1.
Power Consumption : 20 watts max.
identical to the standard 508, 528 and 528F models.
Power Supply (Internal -48 VDC)
Output Power: 40 watts, max.
B3.0 APPLICATIONS

The 48 VDC terminal block on the Magnum 500-series is located on the rear of
the unit and is equipped with three (3) screw-down lead posts. The leads are identified as
negative (-), positive (+), and chassis ground (GND). The actual connection procedure is
Terminal Block on Magnum
very straightforward. Simply connect the DC leads to the Magnum unit, beginning with
Operation of the Magnum 508, 528 and 528F with -48VDC option is identical
This section describes the installation of the 48 VDC power terminal leads to
the 48 VDC power terminal block on the Magnum 500-series switching hub.
Please refer to Section 5.0 for troubleshooting information.
ground. Ensure that each lead is securely tightened.
B6.0 TROUBLESHOOTING
B4.0 INSTALLATION
to that of the standard models.
508/528/528F-48VDC models
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.