EN
GarrettCom logo
Official user manual

GarrettCom 4K16

38 pages·287 KB·Switch·PDF·ENDEFRITNLJA
GarrettCom 4K16
Table of Contents 64 sections Installation and User Guide · 4K16 Switches · Magnum 4K-Series · Magnum ™ 4 K-Series · … ShowHide
Installation and User Guidep.14K16 Switchesp.1Magnum 4K-Seriesp.1Magnum ™ 4 K-Seriesp.2Phone (510) 438-9071p.3Transceivers, 10Mb series Mini-Transceivers and Coax Models Dec., 05p.6ETHERNET CONNECTIVITY PRODUCTSp.6"DESIGNED AND MANUFACTURED IN THE USA"p.6The Magnum Linep.6OVERVIEWp.61.0 SPECIFICATIONSp.7Agency Approvalsp.8Magnum 4K16 Switchesp.9MODEL DESCRIPTIONp.9ONp.12OFFp.12110-220 VACp.12F Hp.13F H F Hp.14L/A SPEEDp.14F/Hp.14= Xp.14POWERp.14ERRORp.14UPLINK 3 4 5 6 7 8 1SWp.19F H = Xp.192SWp.19GARRETTp.19Copper:p.214.0 OPERATIONp.24FKM-2ST Connectorsp.29100BASE-FX,p.29100BASE-FX, Small Form Factor FKM-2MTRJ Connectorsp.30Note: The FKM-Blankp.306.0 TROUBLESHOOTINGp.31CAUTION : Do not pack the unit in Styrofoam "popcorn" type packingp.33APPENDIX A: WARRANTY INFORMATIONp.33B1.0 SPECIFICATIONS - FOR MAGNUM 4K16 DC-POWERED SWITCHESp.34GND GND CHASSISp.34FUSE +p.34HUB POWER SWITCHp.34SUPPLYp.34DC Power Connector: 3 terminals: “ - “, “GND”, “+”p.34APPENDIX B : INTERNAL DC POWER SUPPLY OPTIONSp.34B3.0 APPLICATIONS FOR DC POWERED SWITCHESp.34A+p.34A-p.34_ + GNDp.3536-70VDCp.35B4.0 INSTALLATIONp.35C1.0 SPECIFICATIONS - FOR MAGNUM 4K-SERIES FIBER SWITCHp.36APPENDIX D: INTERNAL DC DUAL-SOURCE POWER OPTIONp.36B6.0 ORDERING INFORMATIONp.36B7.0 TROUBLESHOOTINGp.36B5.0 OPERATIONp.3636-70VDC GNDp.37C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGNp.37A+ AB- B+p.37C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATIONp.37B-p.37B+p.37C5.0 INSTALLATIONp.37C6.0 ORDERING INFORMATIONp.38C7.0 OPERATIONp.38
Page 1 of the GarrettCom 4K16 user manual — Installation and User Guide
Page 1 · click to enlarge
Page 1
GarrettCom 4K16 — Installation and User Guide diagram (page 1)
Fig. 1 · Installation and User Guide

Installation and User Guide

4K16 Switches

Magnum 4K-Series

GarrettCom 4K16 — Installation and User Guide diagram (page 1)
Fig. 2 · Installation and User Guide
Page 2 of the GarrettCom 4K16 user manual — 4K16 Switches
Page 2 · click to enlarge
Page 2

GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a

Attempted service by unauthorized personnel shall render all warranties null

and void. If problems are experienced with the Magnum 4K16 Switches,

of this publication may be reproduced without prior written permission from

Installation and User Guide

consult Section 6, Troubleshooting, of this User Guide.

Copyright © 2005 GarrettCom, Inc. All rights reserved. No part

Magnum ™ 4 K-Series

UL is a registered trademark of Underwriters Laboratories

4K16 Switches

Part #84-000081 (Rev E)

NEBS is a trademark of Telcordia Technologies

Ethernet is a trademark of Xerox Corporation

registered trademark of GarrettCom, Inc.

Printed in the United States of America.

GarrettCom, Inc.

Trademarks

Page 3 of the GarrettCom 4K16 user manual — Phone (510) 438-9071
Page 3 · click to enlarge
Page 3

instructions, may cause harmful interference to radio communications. However, there

guarantee that interference will not occur in a particular installation. If this equipment

Please use the mailing address, phone and fax numbers and email address listed below.

installation. This equipment generates, uses, and can radiate radio frequency energy

and, if not installed and used in accordance with the instructions, may cause harmful

responsible for compliance could void the user’s authority to operate the equipment.

B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to

This Class B digital apparatus meets all requirements of the Canadian Interference-

interference in a residential installation. This equipment generates, uses, and can

- Connect the equipment into n outlet on a circuit different from that to

is no guarantee that interference to radio communications. However, there is no

determined by turning the equipment off and on, the user is encouraged to try to

Cet appareil respecte toutes les exigences du Réglement sur le matériel du

radiate frequency energy and, if not installed and used in accordance with the

does cause harmful interference to radio or television reception, which can be

- Consult the dealer or an experienced radio TV technician for help.

provide reasonable protection against harmful interference in a residential

- Increase the separation between the equipment and receiver.

correct the interference by one or more of the following measures.

Websitehttp://www.GarrettCom.com

Radio Frequency Interference Statement

email support@garrettcom.com

47823 Westinghouse Dr. Fremont, CA 94539

GarrettCom, Inc.

Phone (510) 438-9071

- Reorient or relocate the receiving antenna.

Causing Equipment Regulations.

which the receiver is connected.

Canada. Cet appareil est Classe B.

Show 4 more labels / short text on this page
Federal Communications Commission · Fax (510) 438-9072 · Canadian Emission · Contacting GarrettCom, Inc
Page 4 of the GarrettCom 4K16 user manual — Phone (510) 438-9071
Page 4 · click to enlarge
Page 4
Page 4 of the GarrettCom 4K16 user manual — Phone (510) 438-9071
Page 5 of the GarrettCom 4K16 user manual — Phone (510) 438-9071
Page 5 · click to enlarge
Page 5

Garrett Communications). There are no changes to the content of the material at

Rev C 04/01Change the company name to GarrettCom, Inc. (Formerly it was
Rev E 04/02Updated Rack-mounting, Appendix B & C with 24VDC and 125VDC
Rev A 04/00This revision is the initial release of the 4K16 Switch user

Rev B 12/00 : Addition of Warnings in the French Language.

12/05 : Updated the specifications and minor updates.

Rev D 01/02 : Updated Operating Environment Spec.

10/04Edited minor change
04/03Edited minor change

this time.

manual.

Revisions · addition

Page 6 of the GarrettCom 4K16 user manual — OVERVIEW
Page 6 · click to enlarge
Page 6

6K25 Managed Fiber Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports, mix-and match. Features SFF fiber for up to 25 fiber ports in a 1U unit.

GarrettCom, Inc.offers the premium-quality Magnum™ line of Ethernet LAN

connectivity products with industry-standard functionality and built-in fiber

configurability. Magnum products are designed for use in demanding Carrier Class,

Industrial Grade and OEM applications where reliability is a primary consideration.

Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed

4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto-negotiating full switching performance.

Stackable Concentrators, SNMP optional, 13-Ports

Transceivers, 10Mb series Mini-Transceivers and Coax Models Dec., 05

“Outdoor” Ethernet Switch, for temperature uncontrolled locations

ETHERNET CONNECTIVITY PRODUCTS

Mixed-Media Fiber Hub, 16-port Stackable,10/100 auto-sensing

Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing

"DESIGNED AND MANUFACTURED IN THE USA"

6 10/100 and 2 100Mb fiber ports, can be connected in strings

8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series

10Mb series and 100Mb series, both w/ optional port modules Personal Switches, 10/100Mb

All media combinations, incl. fiber ST, SC, mm., single mode

Repeater Port Modules (RPMs), 6 types for Ethernet media

Bridge Port Modules (BPMs), 4 types, for segment isolation

The Magnum Line

The “X-line” of configurable MiXed Media products:

and mixed-media types, full switching performance.

8 port dual speed, Auto-negotiable with fiber option Personal Hubs, 100Mb or 10/100Mb

OVERVIEW

Mini-Concentrators, 7 Ports, Repeaters, 2-Ports

8-port, with two switched ports (1 fiber built in)

Stackable Hubs, SNMP Optional

Personal Hubs, 10Mb series

(12/05)

Page 7 of the GarrettCom 4K16 user manual — 1.0 SPECIFICATIONS
Page 7 · click to enlarge
Page 7

2.38M frames/sec for 16 100Mbps ports (for Magnum 4K16) 2.68M frames/sec for 16 100Mbps ports & two fiber ports

Address Table Capacity4K node addresses, self-learning w/address aging

Latency: 5 µs + packet time (100 to 100Mbps) 15 µs + packet time (10 to 10 Mbps, and 10 to 100Mbps) Network Standards

2.38M pps for all 16 ports 2.38M pps for all 18 ports (16 RJ-45 ports+ 2 Fiber ports)

Fiber Port, MTRJ-type (plug-in)Fiber optic multi-mode, 100BASE-FX
Fiber Port, SC-typeFiber optic "long-reach” single-mode, 100BASE-FX
Fiber Port, SC-type (snap-in)Fiber optic multi-mode, 100BASE-FX
Fiber Port, ST-type (twist-lock)Fiber optic multi-mode, 100BASE-FX

100BASE-TX (CAT 5 UTP) - 100 m (328 ft)

100BASE-FX, full-duplex, single-mode - 20.0 km (49,215 ft)

100BASE-FX, full-duplex, s.m(Long Reach)- 40.0 km (132,215 ft) Connectors for copper wiring

(for Magnum 4K-Series Fast Ethernet copper ports, use Cat 5 cable)

Unshielded twisted pair, Cat 3 - 100 m (328 ft)

10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)

10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)

100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft)

100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft)

100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)

Twisted Pair at 10/100Mb:RJ-45 shielded, female, front mounted

Fiber Port, SC-typeFiber optic single-mode, 100BASE-FX
Data Rate10 Mbps or 100MB, per port Aggregate Forwarding Rate: (all ports are wire speed)
Aggregate Filtering Rate(all ports are wire speed)

10BASE-FL single-mode fiber optic - 10 km (32,810 ft)

Maximum Standard Fast Ethernet Segment Lengths:

Maximum 10 Mbps Ethernet Segment Lengths

Ethernet V1.0/V2.0 IEEE 802.310BASE-T,
IEEE 802.3u100BASE-TX, 100BASE-FX

(16RJ-45 +2 Fiber ports)

Packet buffer size512K dynamic

Fiber Multi-mode connector types:

Fiber Single-mode connector types:

1.1 Technical Specifications

1.0 SPECIFICATIONS

Performance

Page 8 of the GarrettCom 4K16 user manual — Agency Approvals
Page 8 · click to enlarge
Page 8

(=) for normal port and (X) for an upstream cascaded hub or

& 125VDC supply options (Optional), see Appendices.

Copper defaultAuto-negotiation (Up-link switch for cascading at port #1,

For Dual Source and Redundant DC for –48VDC, 24VDC Power

Ambient Temperature: 25° to 140° F (-5° to 60°C) optional extended range

EnclosureRugged High strength metal. Suitable for stand-alone or

Warranty Three years, return to factory Made in USA

L/ASteady ON for L ink enabled, blinking indicates A ctivity, port
AC Power ConnectorIEC-type, male recessed at rear of chassis,
Fiber default100Mbps Full-duplex, F/H (Full/ Half duplex switch

with adjacent manual ON-OFF switch (on AC models only)

Power Consumption: 17 watts typical, 25 watts max.

Power Consumptionsame as for AC models, see above
Ambient Relative Humidity5% to 95% (non-condensing)
Storage Temperature-40 ° to 185 ° F (-40 ° to 85 ° C)
Dimensions1.75 in H x 17.0 in W x 9.0 in D

4.45cm H x 43.2cm W x 22.9cm D

Weight3.2 lb. (1.4 Kg) rack-mount models Cooling method: Fan cooled, @ 7 cfm
Input Voltage110 to 240 VAC (auto-ranging)
125VDC Power Input Voltage120 to 160VDC Std. Terminal Block : “ -, GND, + ”
-48VDC Power Input Voltage36 to 72 VDC
Input Frequency47 to 63 Hz (auto-ranging)
24VDC Power Input Voltage20 to 36VDC
Altitude-200 to 13,000 ft. (-60 to 4000m)
OptionalETSI and NEBS L3 Certified

Emissions meet FCC Part 15 Class B

Manual switch-selections and jumpers

OFF = Half-Duplex Collision

is transmitting and receiving

F/HON = Full-Duplex Mode
100/10ON = 100Mbps speed OFF = 10 Mbps

UL listed (UL1950), cUL, CE

DC Power Supply (Options)

Agency Approvals

LEDsPer Port
Show 6 more labels / short text on this page
rack-mounting · settings) · switch · Operating Environment · Power Supply (Internal) · Packaging
Page 9 of the GarrettCom 4K16 user manual — MODEL DESCRIPTION
Page 9 · click to enlarge
Page 9

Magnum 4K16 Ethernet Switch with 16 RJ-45 ports, each auto-sensing for

10Mbps/10Mbps FDX/HDX operation. Optional fiber port may be configured one or two from the family of modules

performance. Includes internal auto-ranging power supply,

120VDC power option. Magnum 4K16R “Reverse” model, Same as Model 4K16 Switch except user

below and added another two ports Maxm. User selected

cooling fan, and metal brackets for rack-mounting. LEDs

and user ports are in the front, power inputs is in the rear.

Units with -48V power supply options available RFQ for

FKM-2MTRJ Fiber module with two 100Mbps multi-mode FX “MTRJ”

FKM-1MTRJ Fiber module for 4K-Series Switches, with one 100Mbps

See appendices B and C for information on DC-powered models and options.

FKM-2SSC Fiber module with two 100Mbps 20Km single-mode FX

FKM-1SSC Fiber module with one 100Mbps 20Km single-mode FX

FKM-BLNK Blank face plate, included in 4K16 switch unit when no

provides a full-speed traffic domain with non-blocking

FKM-2SSCL Fiber module with two 100Mbps 40 Km “long-reach”

FKM-1SSCL Fiber module with one 100Mbps 40 Km “long-reach”

fiber port connector types. Each port is switched and

ports and the power input connectors are in the rear.

FKM-2SC Fiber module with two 100Mbps multi-mode FX SC

FKM-2ST Fiber module with two 100Mbps multi-mode FX ST

GarrettCom, Inc. reserves the right to change specifications, performance

Fiber port modules for Magnum 4K-Series (Models 4K16F):

Magnum 4K16 Switches

multi-mode FX “MTRJ” connectors

single-mode FX SC connectors

single-mode FX SC connectors

fiber port option is selected

characteristics and/or model offerings without notice.

LEDs are in the front.

MODEL DESCRIPTION

1.2 Ordering Information

Show 5 more labels / short text on this page
SC connectors · SC connectors · connectors · connectors · connectors
Page 10 of the GarrettCom 4K16 user manual — Magnum 4K16 Switches
Page 10 · click to enlarge
Page 10

product; notify the carrier of any damage that you believe occurred during shipment or

Remove the items from the shipping container. Be sure to keep the shipping

In the event there are items missing or damaged, contact the party from whom

delivery. Inspect the contents of this package for any signs of damage and ensure that

shipping container if possible. Refer to Section 6, Troubleshooting, for specific return

Examine the shipping container for obvious damage prior to installing this

container should you need to re-ship the unit at a later date. To validate the product

you purchased the product. If the unit needs to be returned, please use the original

warranty, please complete and return the enclosed Product Registration Card to

1 Magnum 4K16(standard) or 4K16-R(reverse-mount) Switches

1 AC Power Cord (U.S. and other 115 VAC only)

1 Installation and User Guide (this manual)

1 Set of metal “Ears” for rack mounting

2.1 Inspecting the Package and Product

1 Product Registration Card

This package should contain:

GarrettCom, Inc. as soon as possible.

the items listed below are included.

2.0 Introduction

procedures.

Page 11 of the GarrettCom 4K16 user manual — Magnum 4K16 Switches
Page 11 · click to enlarge
Page 11

number zero, one or two, may be configured from a variety of user selected popular fiber

connector as an additional port. The Magnum 4K16 provide the switching speed and the

own switched 100Mbps or 10Mbps domain, for increased network performance and with

of optional fiber connector types as two additional port as (16 RJ-45+ 2 Fiber ports). All

port modules. The optional fiber ports(two maxm.) can be configured and tested with the

packet buffers and 4K-node address table for advanced performance as well as to support

LANs, with the flexibility of both twisted-pair and fiber switched port. Fiber ports may

reliability to support multiple workgroups, small offices, and departments each with its

The Magnum 16-port 4K16 Switches offer application flexibility with a series

remote offices and in network traffic centers or multi-system power users, the Magnum

changes and expansions. Front-mounted LEDs provide status information on each port.

The Magnum 4K-Series Switches provide high performance plug-and-play operation in

The Magnum 4K16 switches are non-blocking on all ports and include 512K

applicable fiber port connector types (100Mbps FX-ST, SC, MTRJ) along with multi-

mode, single and Long-haul capability are configurable using a family of one- or two -

Designed for use in departments, small offices with multiple workgroups, in

large networks. The Magnum 4K-Series Switches, with store-and-forward switching,

mountable. The optional fiber port(zero. One or two) are user selected, and 100Mbps

fiber port can be configured from the popular fiber port connectors offered. The fiber-

Magnum 4K16 Switches boost the performance of medium sized Ethernet

Magnum 4K16 unit in the factory only. The rest sixteen RJ-45 ports are dual speed

4K16 Series Switches are easy to install and use. Addresses of attached nodes are

automatically learned and maintained, adapting the switching services to network

Magnum 4K16 Series Switches come in chassis size of an 16-port rack-

2.2 Product Description - Magnum 4K16 Switches

filter all faulty packets to minimize traffic congestion.

port modules are offered with factory installed only.

2.2.1 Magnum 4K16F Switch chassis

“future-proof” fiber up-link ports built in.

convenient rack-mount packages.

10/100 Mb auto-negotiating.

Page 12 of the GarrettCom 4K16 user manual — 110-220 VAC
Page 12 · click to enlarge
Page 12

47-63Hz 1.0-0.5A

100Mbps domain, for visual indication of the operating status of each domain. There are

ports as a base model and have two additional fiber port(s) slot 100Mbps fiber (optional

All ports, LED connector and manual switches are located on the front panel

The 4K16 19” rack-mountable Switches comes along with 16 10/100 RJ-45

GarrettCom 4K16 — ON diagram (page 12)
Fig. 3

(POWER) and (ERROR)LEDs for indicating the power up and self test at power up

failed. The IEC standard AC power connector (and a manual ON - OFF power switch)

located at the rear. Fan-driven cooling air flows left to right on standard (non-reverse)

ON

OFF

2.2.2Magnum 4K16R “Reverse” model, front LEDs and connections in rear

of Magnum 4K16 Series Switches. There are Full duplex/Half duplex (F/H) for fiber

port, Link/Activity (L/A) and 10/100(SPEED) LED indicators for each 10Mbps and

110-220 VAC

Figure 2.2.1aFront view, 16-port Magnum 4K16 Series Switches

1 2 3 4 5 6 7 8C 8F 9F 9C 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8C 8F 9F 9C 10 11 12 13 14 15 16

factory configured only). The total port capacity is 18 switched ports.

table-top & rack-mount 4K16C Switch

Figure 2.2.1bRear view - Magnum

models.

Front View · Col/FDX Col/FDX

Page 13 of the GarrettCom 4K16 user manual — F H
Page 13 · click to enlarge
Page 13
GarrettCom 4K16 — F H diagram (page 13)
Fig. 4

LEDs are monitored from the front. Typically such arrangements are found in telco rack

supply (See Appendix A). There is an additional option of a dual-source 48V input (See

port module, all of the fiber ports are of the same speed, the same multi- or single-mode,

1 2 3 4 5 6 7 8C 8F 9F 9C 10 11 12 13 14 15 16

The Magnum 4K16R is like the 4K16 except that the front panel has the LEDs, and all

mounting where cabling is accessed from the rear of the rack while the operating status

The Magnum 4K16R is dual-speed 10/100Mbps switch and has two fiber

connector port options. The switching capability provides high performance support for

Normally the 4K16R is equipped with an optional internal -48VDC power

The two fiber ports are optional for Magnum 4K16-series Switches. In a fiber

and the same connector type. Multi-mode 100Mbps models are available with ST, SC,

2.2.3 Fiber-port module (FKM) options for 4K16’s and 4K16R’s, 100Mb fiber

The DC power feed options and the high quality and versatility make the Magnum

the connecting ports and power feeds are in the back. This is convenient for rack-

4K16FR a good “carrier class” choice for internet infrastructure, ISPs, broadcast

Fig.2.2.3 Fiber-Ports, FKM-ST, FKM-SC, FKM-MTRJ

equipment, medical, brokerage firm and financial facilities.

multiple workgroups or for a power user on each port.

F H

Appendix B).

installations.

Col/FDX Col/FDX

Page 14 of the GarrettCom 4K16 user manual — L/A SPEED
Page 14 · click to enlarge
Page 14

For Magnum fiber FKMs, there are LED’s mounted on the front of the chassis

The Magnum 4K16 copper Series has 16 dual speed 10/100Mb switched RJ-45

negotiating for operation at 10 or 100Mb speed in full- or half-duplex mode (as a default

Link with no traffic and blinking indicates port is receiving and transmitting. The SPEED

cable must be connected into each RJ-45 10/100Mb port and a proper Link (LK lit) must

MTRJ connectors. Single-mode 100Mbps models are available with SC connectors and

The 100Mb fiber port modules on the Magnum 4K16-series normally are set

(factory default) to operate in full-duplex mode for best fiber distance and performance.

blinking for RX port activity, and F/H indicates steady for full duplex and OFF for half

duplex. A fiber cable must be connected to each 100Mb port and a proper link (LK lit)

must be made with the device at the other end of the cable in order for the LK LEDs to

setting). They independently move to half-duplex mode at 10 Mb or at 100Mb speed if

There are three LED’s for each port. The L/A (Link/Activity) steady ON for

when OFF (when auto-negotiation is not disabled). The F/H LED is ON to indicate full-

duplex operation and OFF to indicate half-duplex mode and collisions. A twisted pair

be made with the device at the other end of the cable in order for the LEDs to provide

On the Magnum 4K16 fiber series switches, the user may select full- or half-duplex

auto-negotiating ports. The 10/100Mb switched ports are independently N-way auto-

(10/100Mb) LED indicates operation at 100Mb speed when ON and at 10 Mb speed

mode per-port with a manual switch (F-H) located underneath the fiber ports (See

the device at the other end of the twisted pair cable is half-duplex or is not an auto-

labeled as port 8F and 9F. The Link (L/A) LED indicates ON with Link enabled,

2.2.4 4K16, 10/100 Dual-speed switched ports, RJ-45 (copper only)

Section 3.4) for the flexibility to adapt to any type of Fast Ethernet devices.

1 2 3 4 5 6 7 8C 8F 9F 9C 10 11 12 13 14 15 16

F H F H

“Long-reach” for extra (up to 40 Km) long distance.

provide valid indications of operating conditions.

valid indications of operating conditions.

L/A SPEED

F/H

= X

POWER

ERROR

negotiating device.

Page 15 of the GarrettCom 4K16 user manual — F H F H
Page 15 · click to enlarge
Page 15

with cross-over switch. (See Section 4.4 for more details about Up-link). Like all 4K16

While other switching technologies such as "cut-through" or "express" impose

minimal frame latency, they will also permit bad frames to propagate out to the Ethernet

there is no way to filter frames with a bad CRC (the entire frame must be present in order

traffic congestion, especially at peak activity. Since collisions and bad packets are more

The port#1 is equipped with a Media Dependent Interface (MDI-X)

device. When the Up-link port is used to cascade two Magnum 4K16 together, the auto-

packet) is loaded into the Switch’s memory and inspected before forwarding can occur.

which are a result of late collisions, to be forwarded to add to the network traffic. Since

for CRC to be calculated), the result of indiscriminate cut-through forwarding is greater

Magnum 4K16 Switches dynamically allocates buffer space from a 512K memory pool,

ports, resulting in a small, fixed number of packets to be stored per port. When the port

movable switch to simplify cascaded or up-link connections. It enables the first port’s

RJ-45 cable to either connect to a user station (=) or to be cascaded to another hub (X)

ports, Port # 1 is a dual-speed switch port which will sense the speed of the connected

segments connected. The "cut-through" technique permits collision fragment frames,

(Many other switches have their packet buffer storage space divided evenly across all

traffic on an operating network is constantly varying in packet density per port and in

The Magnum 4K16 Series are store-and-forward switches. Each frame (or

correct CRC, i.e., are good packets. This eliminates the propagation of bad packets,

buffer fills up, dropped packets result.) This dynamic buffer allocation provides the

capability for the maximum resources of the Magnum 4K16 unit to be applied to all

traffic loads, even when the traffic activity is unbalanced across the ports. Since the

aggregate density, the Magnum 4K16 Switches are constantly adapting internally to

This technique ensures that all forwarded frames are of a valid length and have the

likely when traffic is heavy, the result of store-and-forward operation is that more

To minimize the possibility of dropping frames on congested ports, each

ensuring that heavily used ports receive very large buffer space for packet storage.

sensing feature will cause the connecting link to operate at 100Mb speed.

enabling all of the available bandwidth to be used for valid information.

bandwidth is available for good packets when the traffic load is greatest.

2.2.5 Up-link Switch at port#1 for Cascading

2.2.6 Frame Buffering and Latency

Page 16 of the GarrettCom 4K16 user manual — F H F H
Page 16 · click to enlarge
Page 16

sending traffic, which allows a traffic catch-up to occur without dropping packets. Then,

normal packet buffering and processing resumes. This flow-control sequence occurs in a

that its free buffer queue space is low, the Switch prevents more frames from entering by

the length of the frame is a variable here as it is with all store-and-forward switches. The

4K16 Switch’s latency is 5 microseconds plus the packet time at 100Mb. See Section 1.1

Another feature implemented in Magnum 4K16 Switches is a collision-based

flow-control mechanism (when operating at half-duplex only). When the Switch detects

The latency (the time the frame spends in the Switch before it is sent along or

forwarded to its destination) of the 4K16 Switches varies with the port-speed types, and

sends industry standard (full-duplex only) PAUSE packets out to the devices sending

When the Switch detects that its free buffer queue space is low, the Switch

forcing a collision signal on all receiving half-duplex ports in order to stop incoming

packets to cause “flow control”. This tells the sending devices to temporarily stop

small fraction of a second and is transparent to an observer. See Section 4.6 for

provide maximum network performance with the least dropped packets.

additional details.

Specifications.

traffic.

Page 17 of the GarrettCom 4K16 user manual — F H F H
Page 17 · click to enlarge
Page 17

Standard AC power input is IEC plug, auto-ranging for worldwide use. For

available. Dual source DC input can also be selected and configured on the

package with LEDs in front and all Ethernet and power cables in the rear.

As a special feature of the 4K16 Reverse, LEDs are both front and rear. .

Standard 19’ rack mount brackets are included, while ETSI and 23” Telco

Magnum 4K16 Switches are self-learning for node addresses. They can be

The Magnum 4K16 has been tested for operation at temperatures of –5’C

RJ-45 ports provide twisted pair segment connections, with N-way auto-

individually selected. All RJ-45 ports support 10/100 auto-negotiation.

„ Standard AC power input, -48VDC, 24VDC, or 125VDC is available

to 55’C. NEBS-certified models have been tested to a greater range per

Magnum 4K16 Switches provide Fast Ethernet switching on all ports.

They perform high speed filter/forward operations on the traffic, giving

„ Standard (ports in front) or Reverse (ports in rear) rack mounting

The 4K16 is offered with ports and LEDs in the front, or in a “reverse”

placed into operation without complex set-up procedures, even in large

NEBS Level 3 requirements. For details, email mktg@garrettcom.com

Fiber port modules are available with one or two 100Mb mm-ST, SC,

MTRJ or single-mode SC. The configuration flexibility of fiber ports

All fiber and RJ-45 (copper) ports are capable of half- or full-duplex,

special applications, models with –48VDC, 24VDC, or 125VDC are

„ 100Mb switching services for high performance Ethernet LANs

allows 4K16 switches to adapt to mixed and changing fiber types.

„ Plug-and-Play installation for high performance switching

each port’s segment a full 100Mb (or 10 Mb) of bandwidth.

networks. They operate transparent to system software.

„ RJ-45 (copper) ports, with N-way auto-negotiation

„ Full-duplex or Half-duplex operation, auto-sensing

„ Option to configure with one or two fiber ports

–48VDC, 24VDC, and 125VDC input models.

negotiation and switching capability per port.

„ Extended Temperature Operation

2.3 Features and Benefits

are optional.

Page 18 of the GarrettCom 4K16 user manual — F H F H
Page 18 · click to enlarge
Page 18

Magnum 4K16 Switches offer high performance flexibility, and are easily used

characteristic of the 4K16 Switches enables them to inter-connect a series of subnets (one

subnet per 4K-Series Switch) in a LAN traffic center. The subnet connections may be via

either optional fiber or twisted pair cabling, and may be 100Mbps or 10 Mbps speed and

segments in the network center, the Switch needs to provide high-speed switched support

handled by the Magnum 4K16.With the optional Fiber-Port Module, a 2-port FKM, there

is a switched port for distance and high bandwidth throughput to the remote department

Since 100Mb fiber Ethernet has severe distance limitations at half-duplex, it is

negotiation and would not enable the fiber backbone lines to operate full-duplex. But the

in a variety of applications including client/server computing, performance upgrades of

full-or half-duplex mode. The 16 ports switching capability of 4K16 allow to support a

100Mbps full-duplex RJ-45 lines. In addition to interconnecting the two fiber backbone

The Magnum 4K16 equipped with two optional Fiber port and 16 RJ-45 port

necessary in high speed backbones to operate fiber links in the full-duplex mode. Many

modules provides an economical solution, configured with 16 switched ports ( 10/100

The mixed-media capability is ideal for upgrading existing Ethernet LAN

networks, where existing cabling must be accommodated. The fiber-built-in media

departmental backbone. A switch is needed to provide a Fast Ethernet departmental

This requirement for connecting local devices over twisted pair cabling is

low-end switches that only have RJ-45 N-way 10/100Mb ports would need to have a

Magnum 4K16 . . . with two optional switched fiber ports at 100Mb speed, with full-

capability is ideal for integrating future-proof fiber cabling into the LAN structure.

LAN center requiring sixteen high speed LAN segments, at least 14 operating over

media converter on each fiber line. But most media converters do not support auto-

Example1In general application, a Switch is needed to provide a Fast Ethernet

for two central servers, for a connection to a router, and a combination of 10 and

RJ-45) in a rack-mount box. The two Fiber FKM can be selected to provide any

departmental networks, and collapsed backbone applications. The Dual-Speed

100Mbps ports for a local workgroup of over a dozen users, printers, etc.

100Mbps fiber media connector type desired.

larger network with multiple workgroups.

2.4 Applications

consisting of 4 users.

Page 19 of the GarrettCom 4K16 user manual — 2SW
Page 19 · click to enlarge
Page 19

small office networks for each department along with their printer. In addition, the router

The Magnum 4K16 Switch, equipped with dual speed and switching capability

duplex mode as a default setting on fiber ports, and with some RJ-45 N-way 10/100Mb

Fig. 2.4bMagnum 4K16 Switch provides high bandwidth solution for small office
Example 2In another situation for a small office or a classroom, a central Switch is

support for 2 high speed local file servers for different departments to share, and for 5

connection for internet (WAN) and a couple of ports for future expansion are needed.

per port, fits nicely in this environment and offers future fiber backbone expansion.

GarrettCom 4K16 — UPLINK 3 4 5 6 7 8 1SW diagram (page 19)
Fig. 5

needed to provide for a 16-segment 100Mb Fast Ethernet backbone, with switched

GarrettCom 4K16 — UPLINK 3 4 5 6 7 8 1SW diagram (page 19)
Fig. 6
Figure 2.4aThe Magnum 4K16 provides a 10/100Mb backbone with high

PORTS 1SW 2S W 3 4 5 6 7 8

1 2 3 4 5 6 7 8C 8F 9F 9C 10 11 12 13 14 15 16

Magnum DS80 Dual Speed Personal Hub

or class room, offering expansion via “future-proof” fiber.

1 2 3 4 5 6 7 8C 8F 9F 9C 10 11 12 13 14 15 16

PORTS 1SW 2SW 3 4 5 6 7 8

UPLINK 3 4 5 6 7 8 1SW

1 2 3 4 5 6 7 8

F/H

F H = X

2SW

GARRETT

ports as well. . . handles this application readily.

PORTS 1SW 2SW 3 4 5 6 7 8

Magnum DS80 Dual Speed Personal Hub

UPLINK 3 4 5 6 7 8 1SW

PORTS 1SW 2SW 3 4 5 6 7 8

1 2 3 4 5 6 7 8

2SW

bandwidth facility in a department

F/H

F H = X

GARRETT

Magnum DS80 Dual Speed Personal Hub

UPLINK 3 4 5 6 7 8 1SW

PORTS 1SW 2SW 3 4 5 6 7 8

1 2 3 4 5 6 7 8

2SW

F/H

F H = X

GARRETT

UPLINK 3 4 5 6 7 8 1SW

PORTS 1SW 2SW 3 4 5 6 7 8

1 2 3 4 5 6 7 8

2SW

F H = X

Show 19 more labels / short text on this page
5VDC, 2Amps · Link/Ac t · Speed · Power · Error · Tx Rx UPLINK · 5VDC, 2Amps 10 · 5VDC, 2Amps · Li nk/Act · Sp eed · Power · Er ror · Tx Rx UPLINK · Link/Act · Speed · Power · Error · Tx Rx UPLINK · Tx Rx UPLINK
Page 20 of the GarrettCom 4K16 user manual — F H
Page 20 · click to enlarge
Page 20

1.) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment

2.) If the equipment is mounted in an enclosed or multiple rack assembly, adequate air flow must be maintained for proper and

3.) If the equipment is mounted in an enclosed or multiple rack system placement of the equipment must not overload or load

4.) If the equipment is mounted in an enclosed or multiple rack assembly, verify the equipment’s power requirements to prevent

6.) If the intra-building wiring (cabling) is involved with this product(NEBS), then it is recommended to have shielded cable and

5.) If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and

InstallationThis section describes installation of the Magnum 4K-Series Switches, as

layout of the network. Typically the Switch is placed in a central wiring location where

other. These Switches are typically rack mounted in a wiring closet see Section 3.3.2

below), but because they have rubber feet they can also be installed on a shelf or table

Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum 4K-

Series site. The rugged metal case of the Magnum 4K-Series will normally protect it

Before installing the equipment, it is necessary to take the

The location of a Magnum 4K-Series Switch is dependent on the physical

groups of network devices need to be connected in order to communicate with each

from accidental damage in a lab or workplace setting. Maintain an open view of the

front to visually monitor the status LEDs. Keep an open area around the unit so that

cooling can occur from the small fan on the top of the silicon, while the unit is in

ON

OFF

overloading of the building/s electrical circuits.

110-220 VAC

47-63Hz 1.0-0.5A

F H

the shield is grounded at both ends.

well as connection of the various Ethernet media types.

must be less than or equal to 500C.

3.1 Locating Magnum 4K16 Switches

uncompromised earthing path.

unevenly the rack system.

following precautions:

operation. See figure below.

Figure 3.1Location of

safe operation.

4K16’s cooling fan air

3.0 Installation

top.

16-port Magnum · exhaust

Page 21 of the GarrettCom 4K16 user manual — Copper:
Page 21 · click to enlarge
Page 21

The Magnum 4K16 Switches are specifically designed to support all

accomplished by complementing standard RJ-45 copper parts with a family of

Fiber-port Modules (FKMs) which can be individually selected and configured

2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue

connection has been established at both ends (and when power is ON in the unit).

The following procedure applies to installations using a FKM with ST-type fiber

1. Before connecting the fiber optic cable, remove the protective dust caps from the

dampened in alcohol. Make certain the connectors are clean before connecting.

3. Connect the Transmit (TX) port (light colored post) on the Magnum FKM to the

(TX) port of the remote device. Use the non-color coded fiber strand for this.

Receive (RX) port of the remote device. Begin with the color-coded strand of

4. Connect the Receive (RX) port (dark colored post on the PM) to the Transmit

polarity. Swap the fiber cables at the FKM connector to remedy this situation.

The various media types supported along with the corresponding IEEE

If LINK is not lit after cable connection, the normal cause is improper cable

bands at regular intervals; you must use the color-coded strand on the

100BASE-FX mm1 Fiber 2.0km (6,562 ft) FKM-MSC, -MST sgl.m2 Fiber 20.0km (95K ft) FKM-SSC sgl.m2 Fiber 40.0km (12K ft) FKM-SSCL

IEEE Standard Media Type Max. Distance Port Module

5. The LINK LED on the front of the FKM will illuminate when a proper

small form factor mm1 Fiber 2.0km (6,562 ft) FKM-MTRJ,

standard Ethernet media types within a single Switch unit. This is

1 mm = multi-mode 2 sgl.m = single-mode

802.3 and 802.3u standards and connector types are as follows:

connectors. This procedure applies to ports using a FKM-MST.

10BASE-T & 100BASE-TX twisted pair 100m (328 ft) RJ45

per-port. See Section 2.4 for a description of the FKMs.

associated ports at each end of the fiber optic segment.

3.2.1 Connecting Fiber Optic ST-type, “twist-lock”

the cable for this first TX-to-RX connection.

3.2 Connecting Ethernet Media

Copper:

Fiber:

Page 22 of the GarrettCom 4K16 user manual — Copper:
Page 22 · click to enlarge
Page 22

When connecting fiber media to SC connectors, simply snap on the two square

(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx

factor”, because of its small compact size. It looks almost like an RJ-45 port, but compact

making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3

may be used. In either case, the maximum distance for unshielded twisted pair cabling is

mixed-speed network, since dual-speed ports are auto-sensing for either 10 and

connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable

are the diameters of the core and the core plus the cladding respectively). Single-mode

When connecting fiber media to MTRJ connectors, simply snap in the square

The RJ-45 ports of the Magnum 4K-Series can be connected to the following

The following procedure describes how to connect a 10BASE-T or 100BASE-

The following procedure applies to installations using a FKM with SC-type

in size and black color. The MTRJ’s small size and ease of connection make it a good

choice for 100Mbps fiber environment. FKM-MTRJ fiber may be used to connect 100

3.2.5 Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or Shielded)

two media types100BASE-TX and 10BASE-T. CAT 5 cables should be used when

Twisted Pair (CAT 3, 4, 5) 10BASE-T RJ-45

TX twisted pair segment to the RJ-45 port. The procedure is the same for both

fiber connectors, i.e., using FKM-MSC, FKM-SSC single-mode, and FKM10-MSC.

When using single-mode fiber cable, be sure to use single-mode fiber port

fiber allows full bandwidth at longer distances, and may be used to connect 100 Mb

The same procedures as for multi-mode fiber applies to single-mode fiber

3.2.4 Connecting MTRJ Fiber Optic “Snap-In” The “MTRJ” is a multi-mode fiber connector considered as a “small form-

and 100Mb) be used whenever possible in order to provide flexibility in a

male connectors into the MTRJ female jacks of the FPM until it clicks and secures.

Twisted Pair (CAT 5) 100BASE-TX RJ-45

male connectors into the SC female jacks of the FPM until it clicks and secures.

nodes up to 10 Km 18Km with the FKM-SSC and 40 Km with the FKM-SSCL.

Media IEEE Standard Connector

Mb nodes up to 2 Km at full duplex and 412m at half-duplex.

connectors. Follow the steps listed in Section 3.2.2 above.

3.2.2 Connecting Fiber Optic SC-type, "Snap-In"

unshielded and shielded twisted pair cables.

3.2.3 Connecting Single-Mode Fiber Optic

100 meters (328 ft).

100Mb/s.

Page 23 of the GarrettCom 4K16 user manual — F H F H
Page 23 · click to enlarge
Page 23
GarrettCom 4K16 — Copper: diagram (page 23)
Fig. 7 · Copper:
1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is
2. Connect the other end of the cable to the corresponding device 3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is

The brackets attach to the front sides of the Switch, which is then fastened into a standard

LED status indicators should be in plain view and easy to read. Rack-mount installation

requires special 19” rack-mounted brackets and screws (included with each 4K16 unit).

19” rack is a simple procedure. The units are 1U (1.70”) high. When properly installed, the front-mounted

Fig 3.3 Multiple Magnum 4K16 units rack-mounted in a 23” Rack-mount frame

The 23” brackets and ETSI brackets are also available (optional) for rack-

mounting of Magnum 4K Series Switches. The 23” brackets are popular in the Telco

2X 4X 6 8 10 12 14 16 18 20 22 24

1 X 1 3 5 7 9 11 13 15 17 19 21 23

2X 4X 6 8 10 12 14 16 18 20 22 24

1 X 1 3 5 7 9 11 13 15 17 19 21 23

2X 4X 6 8 10 12 14 16 18 20 22 24

1 X 1 3 5 7 9 11 13 15 17 19 21 23

2X 4X 6 8 10 12 14 16 18 20 22 24

1 X 1 3 5 7 9 11 13 15 17 19 21 23

1 2 3 4 5 6 7 8C 8F 9F 9C 10 11 12 13 14 15 16

shielded, either unshielded or shielded cables and wiring may be used.

F H F H

L/A SPEED

F/H

= X

POWER

ERROR

sides of the Magnum Switch unit.

standard for Central Office rack

for larger equipment assemblies

in rack-mounting frames, and are

frequently accessed in operation

along with the necessary screws

brackets are mainly being used

brackets and the ETSI brackets

for attaching the brackets to the

are similar to the 19” brackets

Magnum 4K16 Switch in a

mounting purposes. The 23”

but use metric dimensions.

come as a pair in a package,

industry where they are a

3.3 Rack-mounting

established.

19” RETMA rack.

from both sides.

Show 7 more labels / short text on this page
Magnum 4K16-Series · Ethernet 10/100 Switch · Col/FDX Col/FDX · The ETSI (European · Telephone Standard) brackets · The optional 23” · Installation of a
Page 24 of the GarrettCom 4K16 user manual — 4.0 OPERATION
Page 24 · click to enlarge
Page 24

jumper settings (hardware) configuring to be done at installation or for maintenance. The

Each time a packet arrives on one of the switched ports, the decision is taken to

either filter or to forward the packet. Packets whose source and destination addresses are

on the same port segment will be filtered, constraining them to that one port and relieving

another port segment will be forwarded to the appropriate port, and will not be sent to the

A Magnum 4K-Series provides switched connectivity at Ethernet wire-speed

performance. All ports can communicate to all other ports in a Magnum 4K-Series, but

Magnum 4K-Series units are plug-and-play devices. There is no software or

the rest of the network from processing them. A packet whose destination address is on

The Magnum 4K-Series Switches operate in the store-and-forward switching

mode, which eliminates bad packets and enables peak performance to be achieved when

All 16-port Magnum 4K-Series units have address table capacity of 4K node

addresses, suitable for use in large networks. They are self-learning, so that as nodes are

An address-aging algorithm causes least-used addresses to fall out in favor of

new frequently-used addresses. To reset the address buffer, cycle power down-and-up.

other ports where it is not needed. Traffic needed for maintaining the operation of the

among all of its ports. They support 10/100Mbs for copper media and 10 or 100Mb

separate traffic domain for fiber port to maximize bandwidth utilization and network

added or removed or moved from one segment to another, the 4K16-Port Switch

local traffic on a port will not consume any of the bandwidth on any other port.

This chapter describes the functions and operation of the 4K-Series.

network (such as occasional multi-cast packets) is forwarded to all ports.

automatically keeps up with node locations.

internal functions are described below.

there is heavy traffic on the network.

4.1 Switching Functionality

4.0 OPERATION

Filtering and Forwarding · Address Learning

Page 25 of the GarrettCom 4K16 user manual — L/A SPEED
Page 25 · click to enlarge
Page 25

converters mostly do not support auto-negotiation properly, and require that the switched

F/HFull / Half duplex LED, steady ON when the port is running full

One frequently-used application for the Magnum 4K16 Switch copper ports is

backbone, or to some other remote 100Mb device. In this case, it is desirable to operate

the fiber link at 100Mb speed, and at either half- or full duplex mode depending on the

capabilities of the remote device. Standard commercially-available Fast Ethernet media

port to which they are connected be at 100Mb fixed speed. Attachment to 10/100 auto-

SpeedSpeed LED, ON when the speed is 100Mbps , OFF when the

to connect one of them using a fiber media converter to another Switch in the network

PWR : Power LED, ON when external power is applied to the unit.

device. The Up-link switch allows repeater-to-repeater connections without a special

hub or switch. Verify proper port connection by noting the port’s LINK/ACT status,

which is illuminated when a proper link is made and blinking when there is activity.

L/ASteady ON for link with no traffic, blinking indicates port is

1 2 3 4 5 6 7 8C 8F 9F 9C 10 11 12 13 14 15 16

controls, can be used while cascading with other hub switch or any communicating

cross-over or up-link segment connections from the first 4K16 port to a repeater or

When 4K16 Switch’s RJ-45 copper ports are set for auto-negotiation and

twisted pair cabling from the 4K16 switched port to a user device, or to “X” for

Magnum 4K16s each have one Up-link manual switch next to port #1 which it

Move sliding switch to “=” (or ports 2 thru 16) for straight-through

cross-over cable. It works the same for 10Mb or 100Mb connections.

duplex, blinking for half duplex collisions

4.4 Auto-negotiation, for Fast Ethernet copper ports

F H F H

transmitting and receiving.

Figure 4.3Up-link switch on RJ-45 Port#1

4.3 Up-link Switch, for RJ-45 Port#1 only

negotiation ports typically will not work properly

speed is 10 Mbps.

For Magnum 4K16 models :

L/A SPEED

F/H

= X

POWER

ERROR

4.2 Status LEDs

Magnum 4K16-Series · Ethernet 10/100 Switch · Col/FDX Col/FDX

Page 26 of the GarrettCom 4K16 user manual — 4.0 OPERATION
Page 26 · click to enlarge
Page 26

The auto-negotiation logic will attempt to operate in descending order and will normally

may be limited within that collision domain. The Path Delay Value (PDV) bit-times must

Fast Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.

mode” result can change at any time depending on network changes that may occur). If

When operating in 100Mb half-duplex mode, cable distances and hop-counts

modes selection depending on what the other device supports. These are: (1) 100Mb

full-duplex, (2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex.

arrive at the highest order mode that both devices can support at that time. (Since auto-

negotiation is potentially an externally-controlled process, the original “highest order

the device at the other end is not an auto-negotiating device, the 4K16-Switch’s RJ-45

ports will try to detect its idle signal to determine 10 or 100 speed, and will default to

  • NOTE – some NIC cards only auto-negotiate when the computer system

account for all devices and cable lengths within that domain. For Magnum 4K-Series

network topology must be a “star” type, not a “bus” type. With full-duplex mode, the

connected to an another auto-negotiating device, there are 4 different speed and F/H

Auto-negotiation per-port for 802.3u-compliant switches occurs when:

the devices at both ends of the cable are capable of operation at either 10

that they are in is powered up. These are exceptions to the “negotiate at

cable distance is only limited by the physical layer line driver and cable attenuation.

Full-duplex Ethernet provides separate Transmit and Receive data paths,

enabling simultaneous bi-directional collision-free data movements on a port. The

-- when the second of the two connected devices is powered up*, i.e.,

-- when LINK is re-established on a port after being lost temporarily.

LINK – enabled” rule above, but may be occasionally encountered.

Mb or 100Mb speed and/or in full- or half-duplex mode, and can

send/receive auto-negotiation pulses, and . . .

half-duplex at that speed per the IEEE standard.

when LINK is established for a port, or

4.5 Auto-negotiation full-duplex mode

General information -

Page 27 of the GarrettCom 4K16 user manual — 4.0 OPERATION
Page 27 · click to enlarge
Page 27

negotiation independently on all switched ports. If the device or node on the other end of

speed difference makes the 10Mb port unable to keep up. It can also occur when multiple

100Mb ports are attempting to transmit to one 100Mb port, and in other protracted heavy

blocking) on Full-Duplex ports, which provides for a “PAUSE” packet to be transmitted

frames from entering the device by forcing a collision indication on the half-duplex ports

Magnum 4K16 Switch will negotiate to run full-duplex. If the attached device or node

Magnum 4K- Series Switches incorporate a flow-control mechanism for Full-

burst of activity causes the switch to save frames until its buffer memory is full. This is

to the sender when the packet buffer is nearly filled and there is danger of lost packets.

that are receiving. This temporary “collision” delay allows the available buffer space to

a port’s attached cable supports auto-negotiation or is set to operate as full-duplex, the

doesn’t support F/H mode or fixed at Full or Half duplex (for example, if it is a 10 Mb

most likely to occur when data is moving from a 100Mb port to a 10 Mb port, and the

Magnum 4K-Series Fiber Switches implement the 802.3x flow control (non-

The transmitting device is commanded to stop transmitting into the switched port for

sufficient time to let the Switch reduce the buffer space used. When the available free-

Receiver Sensitivity and Transmitter Power are the parameters necessary to

The Magnum 4K-Series Switches perform half- or full-duplex mode auto-

repeater or a standard 10 Mb hub or older Switch with Fixed full duplex mode), the

Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long

transmitter to start sending the packets. Of course, the transmitting device must also

pressure algorithm on 10/100 Mb ports for flow control. That is, the switch prevents

support the 802.3x flow control standard in order to communicate properly during

compute the power budget. To calculate the power budget of different fiber media

buffer queue increases, the Switch will send a “RESUME" packet to indicate the

4.7 Power Budget Calculations for 4K-Series FKM’s with Fiber Media

where PT = Transmitter Output Power, and PR = Receiver Sensitivity

installations using Magnum products, the following equations should be used:

4K16-Switch’s RJ-45 ports will default to operate at half-duplex.

There are no collision-domain restrictions or limitations.

improve, as the switch catches up with the traffic flow.

4.6 Flow-control, IEEE 802.3x standard

OPB (Optical Power Budget) = PT(min) - PR(min)

traffic situations.

normal operation.

Page 28 of the GarrettCom 4K16 user manual — 4.0 OPERATION
Page 28 · click to enlarge
Page 28
GarrettCom 4K16 — 4.0 OPERATION diagram (page 28)
Fig. 8

Siemens’) web sites and catalogs to provide guidance to network designers and installers.

* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved only

-31 9.0 5.5 2.5 2.0 14 12 5 4

mode 18+ (0.4) 1300 9/125 -15 -31 14 28 17.5 35

-31 9.0 5.5 3.0 2.0 15.8 12.2 5.5 4.0

mode 40 (0.4) 1300 9/125 -5 -34 29 58 32.5 65

  • The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the
  • The worst-case OPB of the fiber link must be greater than the fiber cable’s

full-duplex (factory default) setting for 100Mbps fiber ports must be used,

(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)

where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,

The following data has been collected from component manufacturer’s (HP’s and

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

if the following factors are both applied:

passive Attenuation.

and

Page 29 of the GarrettCom 4K16 user manual — FKM-2ST Connectors
Page 29 · click to enlarge
Page 29

Port Modules (FKMs) for flexible mixed-media connectivity to RJ-45 and fiber

This chapter describes each Fiber-Port Module (FKM), including appearance,

media. Since the Magnum 4K-Series Switches have dual-speed capability for

An important feature of the Magnum 4K-Series is the use of Fiber-

copper ports, the copper port interfaces are designed to support all standard

connecting Ethernet segments with its individual connector type and media.

5.1.1 FKM-MST, 100Mbps multi-mode FX-ST-type, “twist-lock” connector

The Magnum FKM-SSC (and –SSCL) is a single-mode 100Mbps fiber optic

5.1.2 FKM-MSC 100Mbps multi-mode FX-SC-type, “snap-in” connector

5.1.3 FKM-SSC and –SSCL 100Mbps single-mode FX-SC-type, “snap-in”

Ethernet media types at 100Mps speed. Each FKM provides one port for

Each FKM is individually described in the following sections.

For a list of Fiber-Port Module types, refer to Section 1.2

The Magnum FKM-MST is a multi-mode 100Mbps fiber optic module

FKM-2ST Connectors

100BASE-FX,

100BASE-FX,

F H F H

will be added as additional two ports (16RJ-45 + 2 Fiber ports).

to the IEEE-specified switch distance limits, i.e., typically 2000 meters.

5.0 Introduction - Magnum 4K16 Fiber-Port Modules (FKM)

with an SC-type "snap-in" connector instead of an ST-type.

While the functionality of the these two

modules is the same, the FKM-MSC is equipped

The Magnum FKM-MSC is also a

multi-mode 100Mbps fiber optic transceiver

functionality, and status displays

connector. It functions as a fiber optics

network segments. When installed in a

Magnum 4K16 Full-duplex Switch, it

supports fiber optic cable distances up

transceiver to support 100BASE-FX

module, similar to the FKM-MST.

5.1 Product Description

equipped with a dual ST-type

FKM-2SC Connectors

Page 30 of the GarrettCom 4K16 user manual — Note: The FKM-Blank
Page 30 · click to enlarge
Page 30

To distinguish the single-mode FPM-SSC from the multi-mode FKM-MSC, the

The functionality of this 100BASE-FX multi-mode FKM-MTRJ is the same as

connection make it a good choice for 100Mbps Ethernet connectivity. When installed in

100BASE-FX, Small Form Factor FKM-2MTRJ Connectors

a Magnum 4K16 Full-duplex Switch, it supports fiber optic cable distances up to the

the ST and SC-types. Note that the other end of the fiber cable may have a different

module equipped with a dual SC-type connector. It functions as a full fiber optic

5.1.4 FKM-MTRJ, 100Mb multi-mode FX, MTRJ small-form-factor

proper cooling air flow, and for safety, etc.

Note: The FKM-Blank

each empty PM slot.

must be installed in

IEEE-specified switch distance limits, i.e., typically 2000 meters.

the FKM-Blank face plate in order to maintain FKM-Blank

label “Sgl. M.” is at the top of the faceplate of the FKM-SSC.

transceiver to support single-mode fiber networks.

FKM slot. When the Magnum 4K16 chassis

contains less than two front-mounted FKMs,

connector, not necessarily an MT-RJ type.

the empty front slots must be covered with

multi-mode fiber optic module equipped

The FKM-Blank is a blank face

plate that must be installed in any empty

connector. It looks almost like an RJ-45

port, but it is black plastic in color. The

Magnum FKM-MTRJ is a

with a small-form-factor MTRJ-type

MT-RJ’s small size and ease of

5.1.5 FKM-Blank

connector

Page 31 of the GarrettCom 4K16 user manual — 6.0 TROUBLESHOOTING
Page 31 · click to enlarge
Page 31

consistently high performance in all network environments. The installation of Magnum

suggestions listed below prior to contacting your supplier. However, if you are unsure of

the Installation Section of the applicable chapter of this manual. Also check to

good device. Verify whether or not the problem is corrected. If not, go to Step

of the Magnum 4K16 unit or if unknown, contact GarrettCom, Inc.by

intended to help locate, identify and correct these types of problems. Please follow the

1. If difficulty is encountered when installing or operating the unit, refer back to
3. Make sure that an AC power cord is properly attached to each Magnum 4K16

product, it is recommended that the problem device is replaced with a known

5 below. If the problem is corrected, the Magnum 4K16 Series Switches and its associated cables are functioning properly.

5. If the problem continues after completing Step 4 above, contact your supplier

4K16 Series Switches is a straightforward procedure (see INSTALLATION, Section

performing as expected, do not attempt to repair the unit; instead contact your supplier

electrical outlet. Use the PWR LEDs to verify each unit is receiving power.

4. If the problem is isolated to a network device other than the Magnum 4K16

the procedures described in this section or if the Magnum 4K16 Series Switch is not

Should problems develop during installation or operation, this section is

make sure that the various components of the network are interoperable.

2. Check the cables and connectors to ensure that they have been properly

connected and the cables/wires have not been crimped or in some way

impaired during installation. (About 90% of network downtime can be

unit. Be certain that each AC power cord is plugged into a functioning

All Magnum Ethernet products are designed to provide reliability and

2.6); the operation is also straightforward and is discussed in Section 4.

fax, phone or email (support@garrettcom.com) for assistance.

for assistance or contact GarrettCom Customer Support.

attributed to wiring and connector problems.)

6.1 Before Calling for Assistance

6.0 TROUBLESHOOTING

Page 32 of the GarrettCom 4K16 user manual — 6.0 TROUBLESHOOTING
Page 32 · click to enlarge
Page 32

All returns for repair must be accompanied by a Return Material Authorization

d. Any particular application that, when used, appears to create the problem;

3. It is useful to include other network equipment models and related hardware,

including personal computers, workstations, terminals and printers; plus, the

4. A record of changes that have been made to your network configuration prior

https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.

repaired units to the sender with shipping charges prepaid (see Warranty Information,

Appendix A, for complete details). However, if the problem or condition causing the

number(s). Include the date(s) that you purchased the products from your

to the occurrence of the problem. Any changes to system administration

units under warranty. Testing and repair of product that is not under warranty will

1. A complete description of the problem, including the following points:

repair products that are under warranty at no charge, and will return the warranty-

GarrettCom reserves the right to charge for the testing of non-defective

2. An accurate list of GarrettCom product model(s)involved, with serial

GarrettCom will carefully test and evaluate all returned products, will

Failure symptoms, including a full description of the problem.

return cannot be duplicated by GarrettCom, the unit will be returned as:

6.3 Return Material Authorization (RMA) Procedure

(RMA) number. To obtain an RMA number, please use this URL -

Please be prepared to provide the following information.

Name and phone number of your contact person.

Packing List Number (or Sales Order Number)

Please have the following information readily available:

c. The components involved in the problem;

procedures should all be noted in this record.

a. The nature and duration of the problem;

various network media types being used.

No Problem Found.

b. Situations when the problem occurs;

Name of your company / institution

Serial Number (or Invoice Number)

6.2 When Calling for Assistance

result in a customer (user) charge.

supplier.

Your shipping address · Date of installation · Product name

Page 33 of the GarrettCom 4K16 user manual — APPENDIX A: WARRANTY INFORMATION
Page 33 · click to enlarge
Page 33

sheet or bag for shipping protection. ( You may retain all connectors and this

material. This material may cause electro-static shock damage to the unit.

1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic

CAUTION : Do not pack the unit in Styrofoam "popcorn" type packing

2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.

GarrettCom, Inc. warrants its products to be free from defects in materials

Should you need to ship the unit back to GarrettCom, please follow these

replace components in the products that prove to be defective at no charge other

product has been damaged by misuse, misapplication, or as a result of service or

and workmanship for a period of three (3) years from the date of shipment by

This warranty will not be effective if, in the opinion of GarrettCom, the

Please complete the warranty card as this acts as a product registration,

During this warranty period, GarrettCom will repair or, at its option,

than shipping and handling, provided that the product is returned pre-paid to

inspecting any product returned for warranty repair which turns out not to be

3. GarrettCom is not responsible for your return shipping charges. 4. Ship the package to:

GarrettCom reserves the right to make a charge for handling and

and mail it to GarrettCom within two weeks of your purchase.

APPENDIX A: WARRANTY INFORMATION

6.4 Shipping and Packaging Information

47823 Westinghouse Dr. Fremont, CA 94539

Attn.: Customer Service

modification other than by GarrettCom.

GarrettCom, Inc.

Installation Guide.)

GarrettCom.

GarrettCom.

instructions:

faulty.

Page 34 of the GarrettCom 4K16 user manual — A+
Page 34 · click to enlarge
Page 34

B1.0 SPECIFICATIONS - FOR MAGNUM 4K16 DC-POWERED SWITCHES

Magnum 4K-Series-48VDC, 24VDC and 125VDC models are identical to those listed in

inside on each DC power input line behind the two external power connection terminals,

The manual power “On-Off” Switch (optional) is used for powering the unit on

networking solution utilizing a special power supply in hubs with a proven track record.

The –48VDC solution is particularly useful in the telecommunication industry,

B2.0-48VDC, 24VDC & 125VDC POWER OPTION, THEORY OF OPERATION

where it is common for facilities to operate on -48VDC power. Such companies include

the Switch from incorrect DC input connections. An incorrect polarity connection, for

example, will neither affect the Switch, its internal power supply , nor will it blow the

applications where -48VDC, 24VDC & 125VDC power is used as the primary power

With the exception of the power supply, all specifications and functions of

The -48VDC, 24VDC & 125VDC power option are designed using diodes

source. The- 48VDC, 24VDC & 125VDC power configuration provides an Ethernet

GND GND CHASSIS

Power Consumption: Model 4K16: 17 watt typical, 25 watts max.

Power Consumption: Model 4K16: 17 watt typical, 25 watts max.

Power Consumption: Model 4K16: 17 watt typical, 25 watts max.

FUSE +

HUB POWER SWITCH

SUPPLY

Magnum 4K-Series Fiber Switches are easily installed in a variety of

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

Power Supply (Internal 125 VDC Option) Industrial Application

DC Power Connector: 3 terminals: “ - “, “GND”, “+”

APPENDIX B : INTERNAL DC POWER SUPPLY OPTIONS

Power Supply (Internal 24 VDC Option) Industrial Application

B3.0 APPLICATIONS FOR DC POWERED SWITCHES

and off when it is placed into or taken out of service.

Input Voltage120 - 160 VDC
Input Voltage36 - 70 VDC
Input Voltage20 - 36 VDC

A+

A-

Power Supply (Internal -48VDC Option)

This allows the Switch to operate only

applied to the two inputs. It protects

so that the power from an external

source can only flow into the hub.

fuse in the internal power supply.

whenever DC power is correctly

the main manual.

Page 35 of the GarrettCom 4K16 user manual — B4.0 INSTALLATION
Page 35 · click to enlarge
Page 35
Figure B4.1-48VDC Terminal Block on Magnum Ks-48VDC

other communication companies. In addition, many high availability equipment services,

facilities often use a battery backup system to maintain operations in the event of a power

environment, where it is common for facilities to operate on 24VDC or 125VDC power.

This section describes the installation of the -48 VDC, 24VDC & 125VDC power source

leads to the -48 VDC, 24VDC & 125VDC power terminal block on the Magnum Ks. (see

to the Magnum unit, beginning with ground. Ensure that each lead is securely tightened.

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage

1. Minimum 14 AWG cable for connection to a Centralized DC power source. 2. Fastening torque of the lugs on the terminal block: 9 inch pound max. 3. Centralized DC Power Source cable securement, use at least four cable ties to

regular and wireless telephone service providers, Internet Service Providers (ISPs) and

The 125VDC solution is mainly used in Utilities Industries, such as Electric substation,

The actual connection procedure is straightforward. Simply connect the leads

An ON-OFF manual switch is optional for DC power. This can be used to cut

Electrical generating plant etc. Whereas 24VDC application is mainly in the Industrial

Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

The 24VDC and 125VDC solution are particularly useful in the Industrial

environment, such as chemical plants, paper mill, stone quarrying plant, wastewater

so the user may elect to Ground either + or = terminal to suit the customer’s use.

such as broadcasters, publishers, newspaper operations, brokerage firms and other

failure. It is also frequently used for computer system backup, management and

_ + GND

36-70VDC

lead from 48V or –48V supply must be connected to the post labeled “+”.

off power connections and as a RESET for the 4K-Series Switch.

OFF

ON

-48VDC terminal block on the Magnum

4Ks is located on the rear of the unit and is equipped with three (3) screw-down

125VDC options on Magnum 4Ks. The leads are identified as negative (-),

positive (+), and chassis ground (GND).

lead posts. It is similar for 24VDC and

operations monitoring equipment.

B4.0 INSTALLATION

B4.1 UL Requirements

In this picture, the

treatment Plant etc.

figure at the right).

Page 36 of the GarrettCom 4K16 user manual — B7.0 TROUBLESHOOTING
Page 36 · click to enlarge
Page 36

Power Consumption: Model -4K16: 17 watt typical, 25 watts max.

Power Consumption: Model -4K16: 17 watt typical, 25 watts max.

supply, all specifications and configuration options for the Magnum 4K16 -48VDC, 4K16-

C2.0 MAGNUM 4K-SERIES , with -48VDC, 24VDC & 125VDC Dual-Source option

To order the optional -48VDC power supply factory installed, add a suffix of “-

GNDTerminal for “earth” or ground wire connection to the hub chassis
GNDTerminal for “earth” or ground wire connection to the hub chassis
GNDTerminal for “earth” or ground wire connection to the hub chassis

24VDC & 125VDC with this Dual-Source option are identical to those listed in the Magnum 4K-Series Fiber Switches Installation and User Guide, including Appendix B

The 4K16-Switch models with the internal -48VDC, 24VDC & 125VDC Dual-

Operation of the Magnum Ks with the optional -48VDC, 24VDC & 125VDC

Similarly, to order the optional 24VDC or 125VDC industrial specific power

DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”
DC Power ConnectorFirst Source: “A+”, “A -“ , 2nd Source “B - “, “B+”

secure the cable to the rack at least 4 inches apart with the first one located

standard model #. Example: Magnum 4K16- 24VDC or Magnum 4K16- 125VDC.

-48VDC” after the product’s standard model #. Example: Magnum 4K16-48VDC.

supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s

C1.0 SPECIFICATIONS - FOR MAGNUM 4K-SERIES FIBER SWITCH

With the exception of the dual DC input power connections and the power

Power Consumption: Model -4K16: 17 watt typical, 25 watts max.

Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-125V)

Power Supply (Internal, -48VDC Dual-Source, model # Dual-Src-48V)

Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)

APPENDIX D: INTERNAL DC DUAL-SOURCE POWER OPTION

power supply is identical to that of the standard AC-powered models.

InputTwo separate sources, each at 120 - 160 VDC
InputTwo separate sources, each at 36 - 70 VDC
InputTwo separate sources, each at 20 - 36 VDC

Please refer to Section 6.0 for troubleshooting

within 6 inches of the terminal block.

B6.0 ORDERING INFORMATION

“Internal DC Power Supply Option”

B7.0 TROUBLESHOOTING

B5.0 OPERATION

Page 37 of the GarrettCom 4K16 user manual — C5.0 INSTALLATION
Page 37 · click to enlarge
Page 37

Dual-Source Option units are identical to the standard AC-powered models. Refer to the

a) The Switch unit can receive power from either input, “A” or “B”. The hub will normally draw

d) Reverse polarity connections, if they should accidentally occur on either input, will not damage

GarrettCom 4K16 — 36-70VDC GND diagram (page 37)
Fig. 9

c) When one correct DC input is present, the Switch will receive power if the other DC input is

125VDC dual source leads to the -48VDC, 24VDC and 125VDC power terminal block on the Magnum 4K-Series Switch (shown in Figure )

Source power supply are designed for installations where a battery plant is the power

chassis on each DC power input line. A diode is placed in each of the four input lines

b) The Switch unit will not allow power to flow from a higher voltage input to a lower voltage

the Switch or power supply internally (nor will it blow the fuse in the internal power supply)

e) The Switch will not receive power (and will not work) when both inputs are simultaneously

The -48VDC terminal block on the Magnum 4K-Series Switch is located on

FigureC5.0-48VDC Dual-Source, wiring connections to the External

The functionality of the Magnum 4K-Series -48VDC, 24VDC & 125VDC

36-70VDC

main sections of this Installation and User Guide for a detailed description of the

The Dual-Source DC power option is designed using diodes inside of the

because of the blocking action of the diodes. This is true even if one input connection is

This section describes the proper connection of the -48VDC, 24VDC &

36-70VDC GND

C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN

source, and where two separate power sources are utilized in order to increase

user may elect to Ground either + or = terminal to suit the customer’s use.

absent, or even if it is connected with reverse polarity or shorted or grounded.

A+ AB- B+

C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION

Terminal Block on a Magnum 48VDC with Dual-Source option

input, i.e. the two DC power sources are not mixed together by the hub.

its power from the DC source with the highest voltage at a given time.

reversed while the Switch is operating from the other source.

operational uptime and to simplify maintenance.

A-

B-

B+

(behind the four external power connection

power is correctly applied to either or both

terminals) so that power from an external

absent or are both incorrectly connected.

the right rear of the unit and is equipped

with five (5) screw-down lead posts (see

source can only flow into the unit. This

allows the unit to operate whenever DC

identified as positive (A+), negative (A-

), and the secondary power terminals as

Fig C5.0). The primary terminals are

chassis “earth” or ground (GND), is a

negative (B-), positive(B+). The

Magnum 4K-Series Switches.

C5.0 INSTALLATION

threaded post with a #6 nut.

of the two inputs

Page 38 of the GarrettCom 4K16 user manual — C7.0 OPERATION
Page 38 · click to enlarge
Page 38

Before connecting to Terminal block of–48VDC, 24VDC or 125VDC, always

(GND) is optional; it connects to the chassis. Ensure that each lead is securely tightened.

1. Minimum 14 AWG cable for connection to a Centralized DC power source. 2. Fastening torque of the lugs on the terminal block: 9 inch pound max. 3. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located

determine the lead which is more “+ve potential”. The more “+ve” voltage lead from

The connection procedure is straightforward. Simply connect the DC leads to

the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground

To order the optional Dual-Source -48VDC power supply factory installed,

The following must be adhered to in order to conform to UL requirements:

order “Dual-Src48V” as a separate line item following the product model.

Similarly, order “Dual-Src24V” or “Dual-Src125V” as a separate line item

Or Dual-Src48V-SWITCH for model with ON-OFF switch

Dual-Src-48V for regular model with no ON-OFF switch

Operation of the Dual-Source Magnum 4K-Series-48VDC, 24VDC &

use a digital voltmeter to measure the output voltage of the power supply and

The 24VDC & 125VDC terminal block on Magnum 4K-Series Switch also has

Dual-Src24V for regular model with no ON-OFF switch

Dual-Src24V-SWITCH for model with ON-OFF switch

125VDC Switch models are identical to that of the standard models.

ExampleMagnum 4K16-24VDC or Magnum 4K16-125VDC

48V or –48V supply must be connected to the post labeled “+”.

everything similar to –48VDC info. Described above.

within 6 inches of the terminal block.

ExampleMagnum 4K16-48VDC

C6.0 ORDERING INFORMATION

following the product model.

C7.0 OPERATION

C5.1 UL Requirements

Ask about the GarrettCom 4K16

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the GarrettCom 4K16

Be the first to ask — other owners or our team will answer.

Original document

GarrettCom 4K16 manual PDF

38 pages·287 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…