YFPRE1817E



Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.
24-Hour Service Hotline 1-800-551-8633 JULY 09

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
U.S.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.




CHAPTER 1: INTRODUCTION
1.1 General Read the instructions in this manual thoroughly before attempting to operate this equipment. This manual covers current configurations of YFPRE18E. 1.2 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the one below.
DANGER boxes contain information about actions or conditions that may cause or result in injury to personnel, and which may cause damage to your system and/or cause your system to malfunction. Fryers in this series are equipped with the following automatic safety features: 1. Two high-temperature detection features shut off power to the elements should the temperature controls fail. 2. A safety switch built into the drain valve prevents the elements from heating with the drain valve even partially open. 1.3 Computer Information
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of

the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense. The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
1.4 Installation, Operating, and Service Personnel Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.6. All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6. 1.5 Definitions QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual. QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals, firms, corporations, and/or companies which, either in person or through a representative, are engaged in and are responsible for the installation of electrical appliances. Qualified personnel must be experienced in such work, be familiar with all electrical precautions involved, and have complied with all requirements of applicable national and local codes. QUALIFIED SERVICE PERSONNEL Qualified service personnel are those who are familiar with Frymaster equipment and who have been authorized by Frymaster, L.L.C. to perform service on the equipment. All authorized service personnel are required to be equipped with a complete set of service and parts manuals, and to stock a minimum amount of parts for Frymaster equipment. A list of Frymaster Factory Authorized Service Centers (FASC) is included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Frymaster warranty on your equipment.

1.6 Shipping Damage Claim Procedure What to do if your equipment arrives damaged: Please note that this equipment was carefully inspected and packed by skilled personnel before leaving the factory. Frymaster does not assume responsibility for damage or loss incurred in transit. The freight company assumes full responsibility for safe delivery upon acceptance of the equipment. 1. File Claim for Damages Immediately—Regardless of extent of damage. 2. Visible Loss or Damage—Be sure this is noted on the freight bill or express receipt and is signed by the person making the delivery. 3. Concealed Loss or Damage—If damage is unnoticed until equipment is unpacked, notify the freight company or carrier immediately and file a concealed damage claim. This should be done within 15 days of date of delivery. Be sure to retain container for inspection. 1.7 Service Information For non-routine maintenance or repairs, or for service information, contact your local Frymaster Authorized Service Center (FASC). Service information may also be obtained by calling the Frymaster Technical Services Department (1-800-24FRYER) or by e-mail at service@frymaster.com. The following information will be needed in order to assist you efficiently:
Model Number Serial Number Voltage Nature of the Problem
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.

2.1 General Proper installation is essential for the safe, efficient, trouble-free operation of this appliance. Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6 of this manual, should perform all installation and service on Frymaster equipment. Failure to use qualified, licensed, and/or authorized installation or service personnel (as defined in Section 1.6 of this manual) to install or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel. Where conflicts exist between instructions and information in this manual and local or national codes or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed. Service may be obtained by contacting your local Factory Authorized Service Center.

DANGER Do not attach an apron drainboard to a single fryer. The fryer may become unstable, tip over and cause injury. The appliance area must be kept free and clear of combustible material at all times. In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the power switch OFF. Do not attempt to start the fryer(s) until power is restored. This appliance must be kept free and clear of combustible material, except that it may be installed on combustible floors. A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible construction. A minimum of 24 inches (61cm) should be provided at the front of the equipment for servicing and proper operation.

DANGER Prior to movement, testing, maintenance and any repair on your Frymaster fryer, disconnect all electrical power from the fryer. 2.1.2 Electrical Grounding Requirements All electrically operated appliances must be grounded in accordance with all applicable national and local codes, and, where applicable, CE codes. A wiring diagram is located on the inside of the fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages. 2.1.3 Australian Requirements To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.

2.2 Power Requirements


DANGER No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633. 1. Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the top of the frypot to verify that the unit is level, both side-to-side and front-to-back.
To level fryers equipped with legs, the bottom of the legs can be screwed out up to one inch for leveling. Legs should also be adjusted so that the fryer(s) are at the proper height in the frying station.
For fryers equipped with casters, there are no built-in leveling devices. The floor where the fryers are installed must be level. When the fryer is leveled in its final position, install the restraints provided with the unit to limit its movement so that it does not depend on or transmit stress to the electrical conduit or connection. Install the restraints in accordance with the provided instructions (see illustration below). If the restraints are disconnected for service or other reasons, they must be reconnected before the fryer is used.




Control Panel YUM Wingstreet controller shown.

Drain and Filter Handles

TYPICAL CONFIGURATION (YFPRE1817E SHOWN) NOTE: The appearance of your fryer may differ slightly from that shown depending upon the configuration and date of manufacture.

3.1 Equipment Setup and Shutdown Procedures


When using solid shortening, always pre-melt the shortening before adding it to the frypot. If the shortening is not pre-melted, it must be packed down into the bottom of the frypot and between the elements, and the fryer must be started in the melt-cycle mode.
Never cancel the melt-cycle mode when using solid shortening. Doing so will result in damage to the elements and increase the potential for a flash fire.
Shutdown 1. Turn the fryer off. 2. Filter the cooking oil and clean the fryers (See Chapters 4 and 5). 3. Place the frypot covers on the frypots.
Setup

3.2 Controllers This fryer will be equipped the following YUM Wingstreet controller:

Refer to the separate Frymaster Wingstreet Controller User’s Manual furnished with your fryer for the specific controller operating instructions. An overview for the controller is provided below.




operational procedures.

the inherent hazards of operating a hot oil filtration system, particularly the aspects
of oil filtration, draining and cleaning procedures.

the oil moving through the hose lines could jolt a flexible return hose (where
applicable) out of the filter pan, spraying hot oil and causing severe burns.

can spontaneously combust if left soaking in certain shortening material.
This assures the longest life possible for the oil and minimizes flavor transfer.

4. 1 General Frymaster YFPRE18E fryers come equipped with a built-in filtration system. Photos used in the procedure illustrations may differ slightly from the filter unit that came with the frying system. The following procedures apply to all YFPRE18E fryers equipped with built-in filter systems. 4.2 Filtration Preparation On initial installation and before each use, remove all loose parts from the filter, wash the filter pan and all accessories in hot, soapy water and dry thoroughly. 4.2.1 Assembling the Filter The YFPRE18E filter system uses a filter pad held in place by a hold-down ring to filter impurities and debris from the cooking oil. The filter pan is assembled with the following components (see illustration): 1. Filter pan.

4.2.1 Assembling the Filter (cont.) Assemble the filter as follows: 1. Place the support grid in the bottom of filter pan. 2. Place the filter pad on top of the grid, encircling the pick-up tube with the notch in the filter pad. 3. Position the hold-down ring on top of the filter pad. The notch goes around the pick-up tube. 4. Place the crumb screen in the filter pan. Allow the crumb screen to rest on the top edges of the hold-down ring. 5. Place filter pan cover onto the filter pan assembly. Ensure the front cover is correctly positioned over the slip fitting.





Support grid properly placed in filter pan.





The hold-down ring is shown resting on the filter pad. The notches in both are turned toward the pick-up tube.





The filter pan is shown with the pad, hold-down ring and crumb tray in place.

4.2.2 Installing the Filter Slide the filter inside the fryer cabinet. Ensure the male-female slip-fitting coupling is fully engaged. 4.3 Daily Filtration Operation





The filter pan is shown partially inserted under the fryer.
350°F (177°C). Ensure all hoses are connected properly and drain handles are in their proper position prior to operating any switches or valves. Failure to do this can
result in severe burns.
operational procedures. 4.3.1 General Overview The filter pump is turned on only after the oil is brought to operating temperature and drained into the prepared filter pan. The filter motor is then engaged and oil is drawn through the filter pad and pumped back into the frypot. The frypot’s drain remains open during the filtering process. Allow the oil to cycle through the filter pad for approximately 30 minutes. At the end of 30 minutes, close the drain valve and allow the pump to fill the frypot to the top OIL LEVEL line. Leave the pump running for 15-30 seconds after bubbles appear in the frypot to ensure all oil is pumped from the drain pan and the lines.

4.3.2 Filtering Tools Assemble tools to be used for filtering. These are supplied with the filter starter kit included with the fryer/filter system:

or near 350°F (177°C). Ensure all hoses are connected properly and drain handles
are in their proper position before operating any switches or valves. Wear all appropriate safety equipment when draining and filtering cooking oil or shortening.

disposal.

overflow and spillage of hot oil/shortening.


maximum fill line located on the container.

an empty frypot will severely damage the frypot and void all applicable warranties

shortening will rush out creating the potential for severe burns.
DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage
to the ball inside will result in leaks and will void all applicable warranties. 4.4.1 Pan Preparation See Section 4.2.1– Assembling the Filter, and Section 4.2.2– Installing the Filter 4.4.2 Filter Operation

temperature [~350°F (~177°C)]. 1. Turn the fryer off. Ensure the filter pan assembly is prepared as described in Section 4 2. .2.1– Assembling the Filter. 3. Remove fry baskets from frypot. Prior to filtering, skim large debris from the oil. Use extreme caution, as oil is at or near operating temperature, 350°F /177°C). 4. Remove the support grid from the frypot using the clean-out rod or tongs. Stir the oil with the L-shaped Teflon brush to suspend debris prior to draining.


Prior to filtering, skim any large debris from oil in frypot.

4.4.2 Filter Operation (cont.)





5. After ensuring the filter pan is correctly positioned under the drain tube and the pan is properly connected, open the drain valve by pulling the blue handle to the left. Drain only one frypot at a time. 6. After all oil has drained from the frypot into the filter pan, twist the red handle to open the oil return line and activate the filter pump. 7. Oil will begin to pump from the filter pan into the frypot. If the frypot has sediment deposits, clean with the cleaning brush included with the fryer. 8. Allow the oil to circulate for approximately 30 minutes (process known as "polishing") to remove suspended particles. 9. After the filter cycle is complete, close the drain valve (push the blue handle to the left until it stops) and allow the fryer to refill. 10. After all oil is pumped back into the frypot, bubbles will form, indicating air in the oil return lines. Allow the oil to bubble for 10-15 seconds to ensure all oil is evacuated from the return lines. Twist the red handle to close the oil return valve and deactivate the filter pump. 11. If the oil level is low, add oil until the level is at the top OIL LEVEL line. Remember, the oil is at operating temperature. 12. Replace the frypot grid, using care not to splash hot oil. Turn the fryer on.
The blue handle drains the frypot. The red handle operates the filter pump.

4.4.2 Filter Operation (cont.)

Empty the filter pan crumb tray into a fire- proof container at the end of frying operations each day. DO NOT ALLOW CRUMBS TO ACCUMULATE IN TRAY.


can spontaneously combust if left soaking in certain shortening material.
a tight fit and should only be removed for cleaning.



WARNING Use a commercial-grade cleaner formulated to effectively clean and sanitize food-contact surfaces. Read the directions for use and precautionary statements before use. Particular attention must be paid to the concentration of cleaner and the length of time the cleaner remains on the food-contact surfaces. 5.1.1 Clean Inside and Outside of the Fryer Cabinet – Daily Clean inside the fryer cabinet with a dry, clean cloth. Wipe all accessible metal surfaces and components to remove accumulated oil and dust. Clean outside the fryer cabinet with a clean, damp cloth soaked with detergent. Wipe with a clean, damp cloth. 5.1.2 Clean the Built-in Filtration System – Daily

5.1.3 Clean the Frypot and Heating Elements- Weekly

5.2.2 Built-In Filtration System

6.1 Introduction This section provides an easy reference guide to some of the common problems that may occur during the operation of this equipment. The troubleshooting guides that follow are intended to help correct, or at least accurately diagnose, problems with this equipment. Although the chapter covers the most common problems reported, you may encounter problems that are not covered. In such instances, the Frymaster Technical Services staff will make every effort to help you identify and resolve the problem. When troubleshooting a problem, always use a process of elimination starting with the simplest solution and working through to the most complex. Never overlook the obvious – anyone can forget to plug in a cord or fail to close a valve completely. Most importantly, always try to establish a clear idea of why a problem has occurred. Part of any corrective action involves taking steps to ensure that it doesn’t happen again. If a controller malfunctions because of a poor connection, check all other connections, too. If a fuse continues to blow, find out why. Always keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system. Before calling a service agent or the Frymaster HOTLINE (1-800-551-8633):

6.2 Troubleshooting 6.2.1 Controller and Heating Problems
A. Plug power cord in and verify
A. Power cord is not plugged in or
that circuit breaker is not tripped.
circuit breaker is tripped.
B. If any of the components in the
power supply system (including the transformer and interface board) fail, power will not be supplied to the controller and it will not function. Call FASC.
activate. B. Controller or power supply
component or interface board has failed.
A. A drain safety switch prevents
the heating element from being energized if the drain valve is not fully closed. Verify that the drain valve is fully closed.
A. Drain valve is open.
B. If the circuitry in the fryer
Fryer does not heat.
control system cannot determine the frypot temperature, the system will not allow the element to be energized or will de-energize the element. Call FASC.
B. One or more other components
have failed.
Controller won't

This is normal behavior. Refer to the separate YUM! Wingstreet Controller Manual.
cycles on and off when first started.
Fryer is in melt-cycle mode.
Fryer heats until high limit trips with
Temperature probe or controller has failed.
Turn fryer off and call FASC.
heat indicator ON.
Contactor or controller has failed. Call FASC.
without heat indicator ON.
Call FASC.
The high limit thermostat or contactor has failed.
ON.
6.2.2 Filtration Problems
A. Verify that the power cord is
A. Power cord is not plugged in or
fully plugged in. If so, verify that circuit breaker is not tripped.
circuit breaker is tripped.
B. If the motor is too hot to touch
for more than a few seconds, the thermal overload switch has probably tripped. Allow the motor to cool at least 45 minutes then press the Pump Reset Switch.
B. Pump motor has overheated
causing the thermal overload switch to trip.
start.
C. Blockage in filter pump.
C. Pump blockages are usually
caused by sediment buildup in the pump due to improperly sized or installed filter paper and failure to use the crumb screen. Call FASC.
Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If the pump motor hums for a short time and then stops, the probable cause is blockage of the pump itself.

Blockage in filter pan suction tube.
The blockage may be caused by sediment buildup or, if solid shortening is used, solidified shortening in the tube. Use a thin, flexible wire to remove the blockage. If the blockage cannot be removed, call FASC.
but oil does not return to frypot and
Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If bubbling oil occurs, there is a blockage in the filter pan suction tube.
there is no bubbling
oil.
A. If using filter paper or pad
configuration, verify that filter screen is in bottom of pan with paper or pad on top of screen.
Verify that O-rings are present and in good condition on filter pan connection fitting.
A. Improperly installed filter pan
Filter pump runs, but oil return is very
components.
oil occurs.
If using Magnasol filter assembly, verify that O-ring is present and in good condition on filter screen fitting.
B. In order to properly filter, the
B. Attempting to filter with oil that
oil or shortening should be at or near 350ºF (177ºC).
is not hot enough.
Filter pump runs · slow and bubbling




Frymaster, L.L.C., 8700 Line Avenue, Shreveport, Louisiana 71106
TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 (Tech Support) 1-318-219-7135
1-800-551-8633 JULY 2009
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Controller won't activate. | A. Power cord is not plugged in or circuit breaker is tripped. | A. Plug power cord in and verify that circuit breaker is not tripped. | p.28 |
| Controller won't activate. | B. Controller or power supply component or interface board has failed. | B. If any of the components in the power supply system (including the transformer and interface board) fail, power will not be supplied to the controller and it will not function. Call FASC. | p.28 |
| Fryer does not heat. | A. Drain valve is open. | A. A drain safety switch prevents the heating element from being energized if the drain valve is not fully closed. Verify that the drain valve is fully closed. | p.28 |
| Fryer does not heat. | B. One or more other components have failed. | B. If the circuitry in the fryer control system cannot determine the frypot temperature, the system will not allow the element to be energized or will de-energize the element. Call FASC. | p.28 |
| Fryer repeatedly cycles on and off when first started. | Fryer is in melt-cycle mode. | This is normal behavior. Refer to the separate YUM! Wingstreet Controller Manual. | p.29 |
| Fryer heats until high limit trips with heat indicator ON. | Temperature probe or controller has failed. | Turn fryer off and call FASC. | p.29 |
| Fryer heats until high limit trips without heat indicator ON. | Contactor or controller has failed. | Call FASC. | p.29 |
| Fryer stops heating with heat indicator ON. | The high limit thermostat or contactor has failed. | Call FASC. | p.29 |
| Filter pump won't start. | A. Power cord is not plugged in or circuit breaker is tripped. | A. Verify that the power cord is fully plugged in. If so, verify that circuit breaker is not tripped. | p.29 |
| Filter pump won't start. | B. Pump motor has overheated causing the thermal overload switch to trip. | B. If the motor is too hot to touch for more than a few seconds, the thermal overload switch has probably tripped. Allow the motor to cool at least 45 minutes then press the Pump Reset Switch. | p.29 |
| Filter pump won't start. | C. Blockage in filter pump. Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If the pump motor hums for a short time and then stops, the probable cause is blockage of the pump itself. | C. Pump blockages are usually caused by sediment buildup in the pump due to improperly sized or installed filter paper and failure to use the crumb screen. Call FASC. | p.29 |
| Filter pump runs but oil does not return to frypot and there is no bubbling oil. | Blockage in filter pan suction tube. Test: Close the drain valve and pull the filter pan out from the fryer. Activate the pump. If bubbling oil occurs, there is a blockage in the filter pan suction tube. | The blockage may be caused by sediment buildup or, if solid shortening is used, solidified shortening in the tube. Use a thin, flexible wire to remove the blockage. If the blockage cannot be removed, call FASC. | p.30 |
| Filter pump runs, but oil return is very slow and bubbling oil occurs. | A. Improperly installed filter pan components. | A. If using filter paper or pad configuration, verify that filter screen is in bottom of pan with paper or pad on top of screen. Verify that O-rings are present and in good condition on filter pan connection fitting. If using Magnasol filter assembly, verify that O-ring is present and in good condition on filter screen fitting. | p.30 |
| Filter pump runs, but oil return is very slow and bubbling oil occurs. | B. Attempting to filter with oil that is not hot enough. | B. In order to properly filter, the oil or shortening should be at or near 350ºF (177ºC). | p.30 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.