Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.
24-Hour Service Hotline 1-800-551-8633

Please read all sections of this manual and retain for future reference.
Installation, maintenance, and repairs should be performed by your Frymaster/Dean
Factory Authorized Service Agency.

Installation MUST conform to local codes, or in the absence of local codes, with the
latest edition of the National Electric Code, N.F.P.A. 70.

This filter is equipped with a three-prong, grounded plug for your protection against
shock hazard and should be plugged directly into a properly grounded, three-hole receptacle. Do not cut off, remove or otherwise bypass the grounding prong on this
If it is necessary to use an extension cord, it MUST be a three-conductor, grounded

Hot fluid – Do not fill above a point 1-½ inch below the OIL CONTAINER RIM.


and this appliance MUST NOT be cleaned with a water jet.


cleaning and thoroughly dry the filter unit before reconnecting to electrical power

fireproof container at the end of frying operations each day. Some food particles can
spontaneously combust if left soaking in certain shortening material.

and technical procedures and may not conform to on-site management operational

SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS
ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY
OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE



1.1 Parts Ordering/Service Information Place parts orders directly with your local Frymaster/Dean Factory Authorized Service Center. A list of FASCs was included with the filter when shipped from the factory. If you do not have access to this list, please contact the Frymaster/Dean service department at 1-800-551-8633 or 1-318-865- 1711, or go to Frymaster/Dean’s website at: www.frymaster.com To help speed your order, the following information is required:
To assist you more efficiently, the following information will be needed:
Model Number Type Serial Number Optional Features
Nature of Problem:
Additional information (i.e. oil temperature at filter time, time of day and other pertinent information) may be helpful in solving your service problem.

1.3 After Purchase In order to improve service, have the following chart filled in by the Dean Authorized Service Technician who installed this equipment.





1.5 Service Personnel Definitions A. Qualified and/or Authorized Operating Personnel
Qualified/authorized operating personnel are those who have carefully read the information
in this manual and have familiarized themselves with the equipment functions, or have had previous experience with the operation of equipment covered in this manual. B. Qualified Installation Personnel
Qualified installation personnel are individuals, firms, corporations, or companies that are
responsible for the installation of electrical appliances, either in person or through a representative. Qualified personnel must be experienced in such work, be familiar with all electrical precautions involved, and have complied with all requirements of applicable national and local codes. C. Qualified Service Personnel
Qualified service personnel are those who are familiar with Frymaster/Dean equipment and
have been authorized by Frymaster/Dean to perform service on Frymaster/Dean equipment. All authorized service personnel are required to be equipped with a complete set of service parts manuals and stock a minimum amount of parts for Frymaster/Dean equipment. A list of Frymaster/Dean Factory Authorized Service Centers (FASCs) was included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Frymaster/Dean warranty on your equipment.

2.1 General YPF95 portable filters can be used with a variety of Frymaster fryers, as well as other manufacturers’ equipment. Oil capacity is approximately 105 pounds. Unit specifications are listed below.


YPF95 Series filter unit dimensions (unit and tank heights are measured from bottom of casters to top of unit and tank, respectively).

2.1 General (cont.) Oil or shortening is gravity-drained from the fryer into the filter, and then filtered through filter paper. Filter powder, which enhances the filtering process, is distributed over the paper prior to filtering. All units are shipped completely assembled with accessories packed inside the filter pan. All units are adjusted, tested and inspected at the factory before shipment.
the inherent dangers of operating a hot oil filter system, particularly the aspects of
oil filtration, and draining/cleaning procedures. An ON/OFF switch activates/deactivates the filter pump, and a 7-amp (120V), or 5-amp (230V) circuit breaker switches the power OFF if an overload occurs. An internal backup thermal- overload switch on the pump-motor provides additional protection. NOTE: If the circuit breaker is triggered,
depress the reset button to activate the circuit after the failure has been detected and repaired.
2.2 Rating Plate Information on the rating plate includes model and serial numbers, as well as electrical requirements. The rating plate is located on the back housing, near the electrical receptacle. Have the rating plate information handy when communicating with the factory about a unit or requesting special parts or information. Without rating plate information, proper identification of the unit cannot be confirmed.

2.3 Pre-Installation NOTE: Failure to use qualified service personnel will void the Frymaster/Dean warranty.
A. Standards: Use of this filter unit must be in accordance with all applicable state and local
codes.
electrical supply. International/CE units require 230V 50 Hz., 7 amp electrical supply. Units are equipped with a grounded male receptacle for use with a 16-3 SJT power cord set. If an extension cord is required, it must be a three-conductor, grounded power cord of at least 16 gauge. 2.4 Unpacking the Filter System Ensure the container is upright. Unpack the filter carefully and remove all accessories from the carton. Do not discard or misplace parts and/or accessories; they will be needed for filter setup and operation. Any accessories or starter kits included with the unit will be packaged inside the filter tank. After unpacking, immediately check the equipment for visible signs of shipping damage. If such damage has occurred, contact the carrier and file the appropriate freight claims. Do not contact the factory, as the responsibility of shipping damage is between the carrier and dealer or end-user. If your equipment arrives damaged: a. File claim for damages immediately – Regardless of extent of damage. b. Visible loss or damage – Be sure this is noted on the freight bill or express receipt and is
signed by the person making the delivery.
c. Concealed loss or damage – If damage is unnoticed until equipment is unpacked, notify
freight company or carrier immediately, and file a concealed damage claim. This should be done within 15 days of date of delivery. Retain the shipping container for inspection. NOTE: Frymaster does not assume responsibility for damage or loss incurred in transit.

CHAPTER 3: FILTER PREPARATION
3.1 Assembling The Filter System On initial installation and before each use, remove all loose parts from the filter, wash the filter pan and all accessories in hot, soapy water and dry thoroughly.
warranty will be voided. YPF95 Series portable filtration systems use a filter support grid, one sheet of filter paper and a hold-down ring to secure the filter paper in place. See illustration for proper assembly. 1. Filter Pan Cover Front 2. Filter Pan Cover Rear 3. Hold-Down Ring 4. Filter Paper (one sheet) 5. Screen/Sana Grid 6. Filter Pan Assembly A. First, place the Sana Grid in the bottom of filter pan.
B. Place one sheet of filter paper on top of the Sana Grid. Ensure the paper evenly covers the filter
pan bottom. C. Position the hold-down ring on top of the filter paper securely against the filter pan bottom,
forming a tight seal. D. Sprinkle 8 ounces of filter powder over the filter paper, distributing the powder as evenly as
possible. If filtering a second frypot immediately after the first, add only 4 ounces of filter powder for the second filtering. E. Place filter pan covers onto the filter pan assembly. F. Position filter in the space between the two fryers. Lock the rear casters to prevent filter from
moving out of position during the filtering process.


YPF95 portable filter positioned correctly between two fryers with rear casters locked in place.
G. Align the drain pipes over the front filter pan cover. Remove the front cover and replace it with
the oil baffle (as shown below). The baffle should sit on the hold-down ring inside the filter pan and will prevent splashing during filtration.

3 4 1. Oil Baffle (remove front lid) 2. Filter Pan Cover, Rear 3. Filter Pan 4. Drain Tube (fryer to filter)
Remove the front filter pan cover and insert the oil baffle to prevent splashing and movement during filtering. The oil baffle fits straight down over the two drain tubes and rests on the hold-down ring frame.

4.1 General YPF95 Series portable filters are designed to operate primarily as an independent filter unit. Operations always start by ensuring the unit is properly plugged in and situated in the filter space between the fryers. The general layout of a YPF95 Series portable filter with major components identified is illustrated below.
Arrows indicate direction of oil flow during the filtration process.

4.2 Filtering Tools These tools are not required, but are recommended to make the filtering task easier. A. Measuring Cup: Used to measure eight ounces by volume of filter powder.
B. Scrub Brush: To clean sediment and residue from the filter pan and frypot.
C. Appropriate Clothing.
4.3 Filter Preparation 1. Ensure the YPF95 portable filter is positioned between fryer(s) it is being used to filter. The casters must be locked in place and the faucet must be over an appropriate frypot. Remove the front filter pan lid and place the oil baffle over the drain pipes and into the uncovered portion of the filter.
can spontaneously combust if left soaking in certain shortening material. 4.4 Changing Filter Paper Filter paper should be replaced after each filter session, and most certainly at the beginning of each workday. If filter paper is replaced once per day, excess sediment should be scraped from the filter paper after each frypot is filtered (see photo). Use care not to tear the paper when scraping off sediment. Filter at closing if possible. This ensures the oil is at proper filtering temperature. Note: If filtering at closing, remove and discard the used filter paper in a fireproof container when filter operations are complete. Wash all components in soapy water and dry completely. Remove and replace the paper as follows:

4. Remove and check the Sana Grid for cleanliness and clean if necessary. 5. Check the filter-pan for cleanliness and clean if necessary; check the drain ports at the bottom rear of the filter pan and clear any solidified shortening from the opening (black arrow). 6. Replace the Sana Grid and place a new sheet of filter paper on top of the screen. 7. Replace the hold-down ring in the filter pan on top of the filter paper. 8. Measure 8 ounces of filter powder and distribute evenly over the surface of the paper. 9. Replace the filter pan covers and slide it back into place between the appropriate fryers. Plug in the filter. It is now ready for operation.
Filter assembly. 4.5 Unit Operation When filtering, follow these steps:

4.5 Unit Operation (cont.)

Avoid spilling hot oil onto floor surfaces. When draining fryer into filter, never
Position drain handles properly prior to operating the filter unit. Failure to do this
can result in burn injury to the user. 4. Open the drain valve and allow the frypot oil to drain into the filter pan. 5. Ensure that the YPF95 filter faucet is located over the correct frypot. Turn the filter switch "ON" to begin pumping filtered oil back into the fryer. Allow the oil to recycle through the fryer for a few seconds to wash out sediment on the bottom of the frypot before closing the drain valve.
NOTE: The oil return wand can also be mounted in the wand holster inside the pan, for extended filtering periods (polishing) prior to refilling frypot. NEVER LEAVE THE FILTER SYSTEM UNATTENDED WHILE FILTERING! 6. When filtering is complete, close the drain valve handle. It takes approximately 5 to 7 minutes for the filter to pump all the oil back into the fryer. 7. Before shutting off the filter, allow the pump to run for 10-15 seconds after air starts to sputter through the faucet. Clearing residual shortening or oil from the return lines reduces the likelihood of clogged lines.

or the shortening will solidify and plug the hose or oil return lines as it cools.

5.1 General Cleaning operations fall into three general categories:
the warranty.
Each time the portable filter is used:
irreparable damage to the pump, and void the warranty.

5.3 Daily: Close Of Business At the close of a working day, filter the oil in all fryers. When the last fryer is finished, follow these steps:
Follow the same procedure as for "Daily", with these additional steps:

6.1 Operating Problems Plugged lines and plugged filter paper account for over 90 percent of filtration system malfunctions. A general troubleshooting chart included in this chapter provides systematic instructions to assist the operator in diagnosing common malfunctions. Contact a factory-authorized service technician for troubleshooting beyond the scope of the operator. A. Plugged Lines To guard against plugged lines when using solid shortening, let the faucet sputter for about 10-15 seconds at the end of each filter cycle. This will allow air to move through the lines and keep them from becoming to be plugged.
B. Filter Powder and Plugged Paper Improper use of the filter powder will cause filter paper to become plugged, sealed by a layer of filter powder and debris. The first indication of paper plugging is a slow oil flow return rate and a surging, jerking in the filter unit. To correct this, review the instructions for the correct use of filter powder, and change the filter paper more frequently. When filtering several fryers prior to changing paper, ensure that excess sediment is scraped off the filter paper after filtering each frypot. If plugged paper remains a problem, review the chart in section 6.2 for proper diagnosis. 6.2 General Troubleshooting The following chart contains information to assist the user in diagnosing the most common malfunctions with portable filtration systems. Possible solutions and/or corrective actions are given for each scenario. If the malfunction cannot be diagnosed using the information in this section, contact your Factory Authorized Service Agent for repairs.
qualified personnel.

6.2 General Troubleshooting (cont.)
- Tripped circuit breaker. - Incorrect or no line voltage.
start.
- Allow filter unit to cool for at least 45 minutes and then press the pump reset button on the side of the filter. - Turn filter pump "OFF". Allow oil to cool then empty pan. Verify filter paper is clean and properly installed. Refill pan and restart process.
Pump stops during filtering
process.
- Reset circuit breaker. - Pump is blocked or wiring is loose. Call FASC for service. - Filter pan suction tube is blocked. Use a thin, flexible wire to unclog. - Motor failed; call FASC for service.
Pump starts and abruptly
stops.
- Verify that filter paper is properly installed under hold-down ring.
erratic.
- Solidified oil or sediment is likely clogging the filter hose. Clear hose. - Clogged filter paper. Scrape off excess sediment or replace filter paper.
frypot.

6.3 Wiring Diagrams 6.3.1 YPF95 120V Wiring

6.3.2 YPF95 230V Wiring




7 Main Components


7 Main Components Item Part # Description

26 809-0449 Screw, #10 x ½", Phillip's Truss Head
33 813-0006 Bushing, Hex ½" to 3/8" NPT, Black Metal
34 813-0022 Nipple, ½" x Close NPT, Black Metal
36 813-0093 Nipple, ½" x 4" NPT, Black Metal
* 813-0165 Elbow, Street, ½" x ½" NPT, 90°, Black Metal
* 813-0247 Nipple,1/2" x 3.50 NPT, Black Metal Pipe
* 813-0265 Nipple, ½" x 2.50 NPT, Black Metal
* Not Illustrated




Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000
TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135
1-800-551-8633 819-6325 JUNE 2007
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.