Frymaster, a member of the Commercial Foo d Equipment Ser vice Association, recommends using CFESA Certified Tec hnicians. 24-Hour Service Hotline 1-800-551-8633 JUNE 2007 `8196325~ YPF95 Series Porta.
Please read all sections of this manual and retain for future reference. Installation, maintenance, and repairs s hould be performed by your Frymaster/Dean Factory Authorized Service Agency. WARNING Safe and satisfactory operation of y our equipment depends on its proper installation.
NOTICE: If this filter unit is cleaned with water, disconnect the unit from power source before cleaning and thoroughly dry the filter unit be fore reconnecting to electrical power source. DANGER The optional crumb tray (if equipped) in portab le filter systems must be emptied into a fireproof container at the end of frying ope rations each day .
YPF95 Series Portable Filtration Systems Installation & Operation Manual TABLE OF CONTENTS Page # 1. INTRODUCTION 1-1 2. IMPORTANT INFORMATION 2-1 3. INSTALLATION INSTRUCTIONS 3-1 4. FILTER OPERATION 4-1 5. CLEANING AND MAINTENANCE 5-1 6. TROUBLESHOOTING 6-1 7.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 1: INTRODUCTION 1-1 1.1 Parts Ordering/Service Information Place parts orders directly with your local Frym as ter/Dean Factory Authorized Service Center. A list of FASCs was included with th e filter when shipped from the factory.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 1: INTRODUCTION 1-2 1.3 After Purchase In order to improve service, ha ve the following chart filled in by the Dean Authorized Service Technician who instal led this equipm ent. Authorized Service Technician/FASC Address Telephone/Fax Model Number Serial Number 1.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 1: INTRODUCTION 1-3 1.5 Service Personnel Definitions A. Qualified and/or Authorized Operating Pers onnel Qualified/authorized operating pe rsonnel.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 2: IMPORTANT INFORMATION 2-1 2.1 General YPF95 portable filters can be us ed with a variety of Frymas ter fryers, as well as other manufacturers’ equipment. Oil capacity is appr oximately 105 pounds. Unit specifications are listed below.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 2: IMPORTANT INFORMATION 2-2 2.1 General (cont.) Oil or shortening is gravity-drai ned from the fryer into the filter , and then filtered thro ugh filter paper. Filter powder, which enhances the filteri ng process, is distributed over the paper prior to filtering.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 2: IMPORTANT INFORMATION 2-3 2.3 Pre-Installation NOTE: Failure to use qualified service personnel will void the Fry master/Dean warranty. A. Standards : Use of this filter unit must be in acco rdance with all applicable state and local codes.
YPF95LP SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 3: FILTER PREPARATION 3-1 3.1 Assembling The Filter System On initial installation and before each use, rem ove a ll loose parts from the filte r, wash the f ilter pan and all accessories in hot, so apy water and dry thoroughly.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 3: FILTER PREPARATION 3-2 -A- G. Align the drain pipes over the fr ont filter pan cover. Remove th e front cover and replace it with the oil baffle (as shown below). The baffle should sit on th e hold-down ring inside the filter p an and will prevent splashing during filtration.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 4: FILTER OPERATION 4-1 4.1 General YPF95 Series portable filters are designed to operate primarily as an independent filter unit. Operations always start by ensuring the unit is pr operly p lugged in and situated in the filter space between the fryers.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 4: FILTER OPERATION 4-2 4.2 Filtering Tools These tools are not required, but are recomm ended to m ake the filtering task easier. A. Measuring Cup : Used to measure eight ounces by volum e of filter powder.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 4: FILTER OPERATION 4-3 4.4 Changing Filter Paper (cont.) 4. Remove and check the Sana Grid for cleanliness and clean if necessary.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 4: FILTER OPERATION 4-4 4.5 Unit Operation (cont.) DANGER Do not leave filter unit unattended during the filtering operation. Avoid spilling hot oil onto fl oor surfaces. When draining fryer into filter, never exceed the maximum capacity of the filter pan.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-1 5.1 General Cleaning operations fall into three general categories : • Wiping unit clean, interior and exte rior, after each filter session. • Cleaning, changing filter paper and prepari ng the unit for the next day’s business.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-2 5.3 Daily: Close Of Business At the close of a working day, filter the oil in all f r yers.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 6: TROUBLESHOOTING 6-1 6.1 Operating Problems Plugged lines and plugged filter paper account for ove r 90 percent of filtrati on system malfunctions. A general troubleshooting chart included in this chapter provides systema tic instructions to assist the operator in diagnosing common malfunctions.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 6: TROUBLESHOOTING 6-2 6.2 General Troubleshooting (cont.) Pump won't start. - Tripped circuit breaker. - Incorrect or no line volt age . Pump stops during filtering process. - Allow filter uni t to cool for at least 45 minutes and then press the pump reset button on the side of the filter.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 6: TROUBLESHOOTING 6-3 6.3 Wiring Diagrams 6.3.1 YPF95 120V Wiring Receptacle ON/OFF S wi tc h 7 Amp Cir cuit Brea ker BLK 120 VAC BLK BLK WH T BLK BLK.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 7: PARTS LIST 7-1 7 Main Components.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 7: PARTS LIST 7-2 7 Main Components Item Part # Description 1 106-4589 Filter Pan Assembly 200-8685 Sana Grid Screen 211-8703 Stiffener, Pan Frame, Lef.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS CHAPTER 7: PARTS LIST 7-3 7 Main Components Item Part # Description 25 809-0417 Nut, Flange, ¼"-20 Serrated 26 809-0449 Screw, #10 x ½", Phillip&ap.
THIS PAGE INTENTIONALLY LEFT BLANK.
Frymaster, L.L.C., 8700 Line Av enue, PO Box 51 000, Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Av enue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318- 219-71 40 F.
An important point after buying a device Frymaster YPF95 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Frymaster YPF95 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Frymaster YPF95 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Frymaster YPF95 you will learn all the available features of the product, as well as information on its operation. The information that you get Frymaster YPF95 will certainly help you make a decision on the purchase.
If you already are a holder of Frymaster YPF95, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Frymaster YPF95.
However, one of the most important roles played by the user manual is to help in solving problems with Frymaster YPF95. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Frymaster YPF95 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center