Table of Contents 30 sections Installation, Operation · OCT 2008 *8196329* · NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS · CHAPTER 1: INTRODUCTION · … ShowHide
Page 1 of the Frymaster *8196329* user manual — OCT 2008 *8196329*
Page 1 · click to enlarge
Page 1
Frymaster *8196329* — Installation, Operation diagram (page 1)
Fig. 1 · Installation, Operation
Frymaster *8196329* — Installation, Operation diagram (page 1)
Fig. 2 · Installation, Operation

Installation, Operation

Frymaster *8196329* — Installation, Operation diagram (page 1)
Fig. 3 · Installation, Operation

Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.

24-Hour Service Hotline 1-800-551-8633 Price: $10.00

OCT 2008 *8196329*

Page 2 of the Frymaster *8196329* user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 2 · click to enlarge
Page 2

Please read all sections of this manual and retain for future reference.

Frymaster *8196329* — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS diagram (page 2)
Fig. 4

qualified professional should perform installation, maintenance, and repairs. Installation, maintenance, or repairs by unqualified personnel may void the manufacturer’s warranty. See

Chapter 1 of this manual for definitions of qualified personnel.

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.

the country and/or region in which the appliance is installed.

technical procedures and may not conform to onsite management operational procedures.

NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS

U.S. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept

any interference received, including interference that may cause undesired operation. While

this device is a verified Class A device, it has been shown to meet Class B limits.

Canada This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set

out by the ICES-003 standard of the Canadian Department of Communications.

Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communications du Canada.

Frymaster *8196329* — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS diagram (page 2)
Fig. 5

service instructions thoroughly before installing or servicing this equipment. Only qualified

service personnel may convert this appliance to use a gas other than that for which it was originally configured. See Chapter 1 of this manual for definition of qualified service personnel.

Page 3 of the Frymaster *8196329* user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 3 · click to enlarge
Page 3
Frymaster *8196329* — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS diagram (page 3)
Fig. 6

anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all

from slips or contact with the hot oil.

other appliance.

Frymaster *8196329* — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS diagram (page 3)
Fig. 7

must be posted in a prominent location. This information can be obtained from the local gas

company or gas supplier.

Frymaster *8196329* — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS diagram (page 3)
Fig. 8

at the end of frying operations each day. Some food particles can spontaneously combust if left

soaking in certain shortening material. Additional information can be obtained in the filtration

manual included with the system.

the fryer under a hood. Questions? Call the Dean Service Hotline at 1-800-551-8633.

Frymaster *8196329* — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS diagram (page 3)
Fig. 9

the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for

cleaning.

Page 4 of the Frymaster *8196329* user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 4 · click to enlarge
Page 4
Page 4 of the Frymaster *8196329* user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 5 of the Frymaster *8196329* user manual — CHAPTER 1: INTRODUCTION
Page 5 · click to enlarge
Page 5

CHAPTER 1: INTRODUCTION

1.1 After Purchase In order to improve service, have the following chart filled in by the Frymaster authorized service technician who installed this equipment.

Telephone/Fax Model Number Serial Number Gas Type 1.2 Ordering Parts Customers may order parts directly from their local authorized service agency (ASA). If the telephone number of your ASA is not listed above, call the Frymaster Service Hotline telephone number, 1-800-551-8633. To speed up your order, provide the model number, serial number, gas type, part needed, item part number (if known), and quantity needed.

Authorized Service · Technician/ASA Address

Page 6 of the Frymaster *8196329* user manual — CHAPTER 1: INTRODUCTION
Page 6 · click to enlarge
Page 6

CHAPTER 1: INTRODUCTION

1.3 Service Information Call the Frymaster Service Hotline, 1-800-551-8633, for the location of your nearest factory authorized service center (ASA). To assist you more efficiently, always provide the service technician with the model number, gas type, serial number, and the nature of the problem. 1.4 Computer Information This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While this device is a verified Class A device, it has been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful: "How to Identify and Resolve Radio-TV Interference Problems". This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4. 1.5 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones below.

Page 7 of the Frymaster *8196329* user manual — 1.6 Service Personnel A. Qualified and/or Authorized Operating Personnel: Qualified/authorized operating personnel
Page 7 · click to enlarge
Page 7

CHAPTER 1: INTRODUCTION

1.5 Safety Information (cont.)

1.6 Service Personnel A. Qualified and/or Authorized Operating Personnel: Qualified/authorized operating personnel

are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or have had previous experience with the operation of equipment covered in this manual. B. Qualified Installation Personnel: Qualified/authorized personnel are those who have carefully

read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual. C. Qualified Service Personnel: Qualified service personnel are those who are familiar with

Frymaster equipment and are authorized by Frymaster to perform service on Frymaster equipment. All authorized service personnel are required to be equipped with a complete set of service parts manuals and stock a minimum amount of parts for Frymaster equipment. A list of Frymaster Authorized Service Agencies (ASA’s) was included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Frymaster warranty on your equipment.

Page 8 of the Frymaster *8196329* user manual — 2.1 Receiving and Unpacking Equipment
Page 8 · click to enlarge
Page 8

CHAPTER 2: IMPORTANT INFORMATION

2.1 Receiving and Unpacking Equipment

A. Check that the container is upright. Use an outward prying motion - no hammering - to

remove the carton. Unpack the fryer carefully and remove all accessories from the carton. Do not discard or misplace these, as they will be needed.

B. After unpacking, immediately check the equipment for visible signs of shipping damage. If

damage has occurred, contact the carrier and file the appropriate freight claims. Do not contact the factory. Shipping damage responsibility is between the carrier and the dealer. If your equipment arrives damaged:

1. File claim for damages immediately, regardless of extent of damage.
2. Visible loss or damage: Be sure this is noted on the freight bill or express receipt and is signed by the person making the delivery.
3. Concealed loss or damage: If damage is unnoticed until equipment is unpacked, notify freight company or carrier immediately, and file a concealed damage claim. This should be done within fifteen (15) days of date of delivery. Be sure to retain container for inspection.

C. Frying systems with built-in filtration: Take off the filter support brace and remove the

filter pan from the cabinet.

D. Remove all plastic skin from sides, front, and doors of the fryer(s). Failure to do this prior to

initial fryer operation will make it very difficult to remove later. 2.2 General Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Receiving and Unpacking Equipment, Section 2.1.) The Frymaster YSCFH18G High Efficiency Cool Zone Series Fryers are energy-efficient, gas-fired units, design-certified by the International Approval Services (AGA/CGA), Gaz de France, and NSF International and manufactured to their basic performance and application specifications. All units are shipped completely assembled with accessories packed inside the frypots. All units are adjusted, tested, and inspected at the factory before shipment. Sizes, weights, and input rates of all models are listed in this manual.

Page 9 of the Frymaster *8196329* user manual — 2.5 Pre-Installation
Page 9 · click to enlarge
Page 9

CHAPTER 2: IMPORTANT INFORMATION

2.3 Principles of Operation The incoming gas flows through orifices and is mixed with air in the burners to create the correct ratio for proper combustion. The mixture is ignited at the front end of each heat tube by the pilot light. Internal diffusers slow the flame as it goes through the burner tube. This slow, turbulent flame increases heat transfer to the walls of the tubes to heating the oil more efficiently. 2.4 Rating Plate

This is attached to the inside of the front door panel. Information provided includes the model and serial number of the fryer, BTU/hr (kW/hr) input of the burners, outlet gas pressure in inches W.C. (mbars), and whether the unit has natural (G20/25) or propane (G31) gas orifices.

2.5 Pre-Installation

against electrical shock and must be plugged directly into a properly grounded three-prong receptacle. Do not cut, remove, or otherwise bypass the grounding

prong on this plug.

A. General: Only licensed personnel should install any gas-fired equipment.

1. A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for safety and ease of future service.
2. The Frymaster YSCFH18G gas fryers require 120 volts (AC) 60-cycle electrical service for U.S./Canada/Mexico installations. Fryers are equipped with a 16-3 SJT grounded flexible power cord for a direct connection to the power supply. Amperage draw for each unit depends on the accessories supplied with the unit. See detailed instructions packaged with the fryer line-up.

at 1-800-551-8633.

Page 10 of the Frymaster *8196329* user manual — CHAPTER 2: IMPORTANT INFORMATION
Page 10 · click to enlarge
Page 10

CHAPTER 2: IMPORTANT INFORMATION

2.5 Pre-Installation (cont.)

Frymaster *8196329* — CHAPTER 2: IMPORTANT INFORMATION diagram (page 10)
Fig. 10

of unacceptable concentrations of substances harmful to the health of personnel in

the room in which it is installed. B. Clearances: The fryer area must be free of all combustibles. This unit is design-certified for

the following installations:

1. Commercial installation only; not for household use.
2. Non-combustible floor installation equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch (13-cm) casters;
3. Combustible construction with a minimum clearance of 6-inches (15-cm) side and 6-inches (15-cm) rear, and equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch (13-cm) casters.

C. Installation Standards

1. U.S. installations must meet: 2. Canadian installations must meet: American National Standard Institute CAN 1-B149 Installation Codes ANSI Z83.11 Canadian Gas Association American Gas Association 55 Scarsdale Road 8501 E. Pleasant Valley Road Don Mills, ONT, M3B 2R3 Cleveland, OH 44131 National Electrical Code Canadian Electric Code c22.1, part 1 ANSI/NFPA #70 Canadian Standards Association American National Standard Institute 178 Rexdale Blvd. 1430 Broadway Rexdale, ONT, M9W 1R3 New York, NY 10018 NFPA Standards #96 and #211 3. Australian installations must meet: National Fire Protection Association 470 Atlantic Avenue AS5601/AG601 Installation Codes Boston, MA 02110 Standards Australia International 25 Raglan Street South Melbourne, VIC 3205

Page 11 of the Frymaster *8196329* user manual — CHAPTER 2: IMPORTANT INFORMATION
Page 11 · click to enlarge
Page 11

CHAPTER 2: IMPORTANT INFORMATION

2.6 Air Supply and Ventilation

section. A. Keep the area around the fryer clear to prevent obstruction of combustion and ventilation airflow

and to allow for service and maintenance. Always adhere to the following:

1. Do not connect this fryer to an exhaust duct.
2. Follow installation and adjustment procedure to ensure adequate airflow to the fryer system.

3. A heavy-duty, commercial fryer’s combustion wastes must vent to the outside of the building. A deep-fat fryer must be installed under a powered exhaust hood, or an exhaust fan must be provided in the wall above the unit. Exhaust gas temperatures are approximately 800-1000°F (427-538°C). Check air movement during installation. Strong exhaust fans in the exhaust hood or in the overall air conditioning system can produce slight air drafts in the room and cause erratic burner flames or improper fryer operation.

4. Do not place the fryer’s flue outlet directly into the plenum of the hood, as it will affect the gas combustion of the fryer.
5. Never use the interior of the fryer cabinet for storage or store items on shelving over or behind the fryer. Exhaust temperatures can exceed 800°F (427ºC) and may damage or melt items stored in or near the fryer.
6. Adequate distance must be maintained from the flue outlet of the fryer(s) to the lower edge of the filter bank. Per NFPA Standards No. 96, a minimum of 18-inches (45-cm) should be maintained between the flue(s) and the lower edge of the exhaust hood filter.
7. Filters and drip troughs should be part of an industrial hood, but consult local codes before constructing and installing any hood. The duct system, the exhaust hood, and the filter bank must be cleaned on a regular basis and kept free of grease. 2.7 Equipment Installed at High Altitudes

A. The fryer input rating [BTU/hr (kW/hr)] is for elevations up to 2,000 feet (610 m). For

elevations above 2,000 feet (610 m), the rating should be reduced 4% for each additional 1,000 feet (305 m) above sea level.

B. The correct orifices are installed at the factory if operating altitude is known at time of the

customer’s order.

Page 12 of the Frymaster *8196329* user manual — CHAPTER 2: IMPORTANT INFORMATION
Page 12 · click to enlarge
Page 12

CHAPTER 2: IMPORTANT INFORMATION

2.8 Restraining the Fryer

Hotline at 1-800-551-8633. 1. Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the top of the frypot to verify that the unit is level, both side-to-side and front-to-back.

  • To level fryers equipped with legs, the bottom of the legs can be screwed out up to one inch for leveling. Legs should also be adjusted so that the fryer(s) are at the proper height in the frying station.
  • For fryers equipped with casters, there are no built-in leveling devices. The floor where the fryers are installed must be level. 2. With the fryer level in its final position, install the restraints provided with the unit to limit its movement so that it does not depend on or transmit stress to the electrical conduits/connections or the gas supply line. Install the restraints in accordance with the provided instructions (see illustration below). If disconnected for service or other reasons, the restraints must be reconnected before the fryer is used.
Page 13 of the Frymaster *8196329* user manual — CHAPTER 2: IMPORTANT INFORMATION
Page 13 · click to enlarge
Page 13

CHAPTER 2: IMPORTANT INFORMATION

removed from the fryer before attempting to move it to avoid oil spills, falls and

severe burns. This fryer may tip and cause personal injury if not secured in a

stationary position.

combustible material at all times.

Page 14 of the Frymaster *8196329* user manual — CHAPTER 3: INSTALLATION INSTRUCTIONS
Page 14 · click to enlarge
Page 14

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.1 Installing the Fryer Qualified, licensed, authorized installation or service personnel only (as defined in Section 1.6) should perform the following:

1. Installation and service of Frymaster equipment; 2. Conversion of this appliance from one gas type to another. Failure to use qualified, licensed, and/or authorized installation or service personnel to install, convert to another gas type, or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel. Where conflicts exist between instructions and information in this manual and local code or national codes and regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed. A. Initial Installation: If installed with legs, do not push against any unit edges to adjust its

position. Use a pallet or lift jack to lift it slightly and place it where it is to be installed. B. Relocating the Fryer: If relocating a fryer installed with legs, remove all weight from each leg

before moving.

open flame of any type, including those of broilers and ranges. 3.2 Leg and Caster Installation

with legs must be lifted during movement to avoid damage and possible bodily injury. For a moveable or portable installation, optional equipment casters must be

used. Questions? Call 1-800-551-8633 A. General

1. Because neither legs nor rigid rear casters are secure for long transit, install them near the area of use. This unit cannot be curb mounted and must be equipped with the legs and rear rigid casters provided.
Page 15 of the Frymaster *8196329* user manual — CHAPTER 3: INSTALLATION INSTRUCTIONS
Page 15 · click to enlarge
Page 15

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.2 Leg and Caster Installation (cont.)

2. When positioning the fryer, gently lower it into position to prevent undue strain to the legs and internal mounting hardware. If possible, use a pallet or lift jack to lift and position the fryer. Tilting the fryer may damage the legs.
3. The rigid casters must be installed on the fryer rear channel assembly only. B. Installation
1. Remove unit from pallet.
2. Carefully raise unit with forklift, pallet jack, or other steady means.
3. Place one lock washer on each hex head screw.
4. Insert hex head screws with lock washers [1/4-20 threads by ¾" (19 mm) long] through bolt holes of leg mounting plates and mount to the front channel. Mount rigid casters to the rear channel following the same procedure. Locknuts have been attached to the topside of the base mounting plates at the factory to capture hex head screws as they are screwed in.
5. Tighten the bolts to 50 in-lbf (5.65 joules) minimum torque.
6. After legs and rear rigid casters are installed, proceed to Step 3.3, Leveling the Fryer , to ensure the fryer is level before use.

before installing the casters. 3.3 Leveling the Fryer A. Place a level across the top of the fryer and level the unit front-to-back. If the fryer is uneven

side-to-side, a platform or other surface adjustment is needed; there is no side-to-side level adjustments on a fryer equipped with caster/leg combinations (If a fryer is equipped with legs only, side to side level adjustments can be made. If a fryer is equipped with casters only, no level adjustments to the fryer can be made.). If the fryer is not level, the unit may not function efficiently, the oil may not drain properly for filtering, and it may not match adjacent units in a multi-fryer battery.

Page 16 of the Frymaster *8196329* user manual — CHAPTER 3: INSTALLATION INSTRUCTIONS
Page 16 · click to enlarge
Page 16

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.3 Leveling the Fryer (cont.) • Legs (Only)

1. Adjust leg height with an adjustable or 1 1 / 16 -inch (27-mm) open-end wrench by turning the hex bullet on the bottom of the leg.
2. The hex bullet is for minor leg height adjustment only. Do not adjust more than 1 inch (25 mm). 3. When leveling the unit, the leg body should be held firmly to keep the leg from bending or rotating while turning the hex bullet foot to the required height.
  • Rigid Casters (Only)
1. Install rigid casters on the fryer rear channel only. Legs must be installed on the front channel. 2. There are no level-adjustments for the rigid casters. B. If the floor is uneven or has a decided slope, place the fryer on a smooth platform.

C. If the fryer is moved, re-level the fryer following the instructions given in Steps 3.3, A-C.

D. Installing Optional Swivel Casters

1. Install non-locking casters only at the rear of the unit. 2. Locking casters must be installed at the front of the unit. Locking casters allow the fryer to be "locked" in position for safe operations. 3. Follow the same instructions for leg installations as given above in Steps 3.2, B1-B5.
Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 16)
Fig. 11
Page 17 of the Frymaster *8196329* user manual — CHAPTER 3: INSTALLATION INSTRUCTIONS
Page 17 · click to enlarge
Page 17

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.3 Leveling the Fryer (cont.) ANSI Z83.11/11a-(Latest Edition) requires a fryer be restrained to prevent tipping when installed in order to avoid the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to battery of appliances or installing the fryer in an alcove, or by separate means, such as adequate ties (chains, straps, etc.). A bracket has been provided on the fryer back panel for this purpose. NOTE: The installation must be inspected after it is complete to ensure it meets the intent of these instructions. The on-site supervisor and/or operator(s) should be informed that the appliance is installed with restraints. If restraints are removed to move fryer (e.g., to clean beneath and behind, to relocate) ensure that they are re-installed when fryer is returned to its permanently installed position. For information on fryer restraints, see Section 2.8. 3.4 Gas Connections The gas supply (service) line must be the same size or greater than the fryer inlet line. YSCFH18G gas fryers are equipped with a ¾-inch (22-mm) male inlet. The gas supply line must be sized to accommodate all gas-fired equipment connected to that gas supply. Consult local gas companies/suppliers or your local contractor for minimum supply line requirements. Supply Line Specifications The gas supply lines must be sized as indicated in the chart below, based on the total number of fryers connected to the main gas supply.

Recommended Gas Supply Line Sizes Gas Types Number of Fryers 1 2 to 3 4 or more* Natural Gas ¾" (22 mm) 1" (28 mm) 1¼ " (35 mm) Propane Gas ½" (15 mm) ¾" (22 mm) 1" (28 mm) * When exceeding 18 feet (6 meters) for a configuration of more than four fryers, it is necessary to provide a 1¼" (35 mm) rigid gas connection.

used and all connections must be tested with a solution of soapy water before

lighting any pilots.

Never use matches, candles, or any other ignition source to check for leaks. If gas

odors are detected, shut off the gas supply to the appliance at the main shut-off

valve and immediately contact the local gas company or an authorized service

agency for service.

Page 18 of the Frymaster *8196329* user manual — CHAPTER 3: INSTALLATION INSTRUCTIONS
Page 18 · click to enlarge
Page 18

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.4 Gas Connections (cont.)

Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 18)
Fig. 12

frypot.

Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 18)
Fig. 13

controls will cause improper and dangerous operation. Rigid Connections Check any installer-supplied intake pipe(s) visually and clean metal particles or other foreign matter from the threads before installing into a service line. If the intake pipes are not clear of all foreign matter, the orifices will clog when gas pressure is applied. When using thread compound on gas piping, use very small amounts and only on male threads. Use a pipe thread compound that is not affected by the chemical action of LP gases. DO NOT apply thread compound to the first two pipe threads—doing so will cause clogging of the burner orifices and control valve. Manual Shut-off Valve This gas service supplier-installed valve must be installed in the gas service line ahead of the fryers in the gas stream and in a position where it can be reached quickly in the event of an emergency. Regulating Gas Pressure The fryer and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the gas supply system, especially if the test pressures are in excess of ½ PSI (3,45 kPa/35 mbar). External gas regulators are not normally required on this fryer. A safety control valve protects the fryer against pressure fluctuations. If the incoming pressure is in excess of ½ PSI (3,45 kPa/35 mbar), a step-down regulator is required.

Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 18)
Fig. 14

line if the test pressure is 3,45 kPa (½ PSI, 14" W.C.) or greater to avoid damage to

the fryer’s gas piping and gas valve(s).

Page 19 of the Frymaster *8196329* user manual — CHAPTER 3: INSTALLATION INSTRUCTIONS
Page 19 · click to enlarge
Page 19

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.4 Gas Connections (cont.)

A. Manifold PressureYour local service technician should check the manifold pressure with

a manometer.

1. Check the rating plate for manifold gas pressures. Natural gas units normally require 4" W.C., and propane units normally require 11" W.C. gas pressure.
2. Confirm that the arrow forged into the bottom of the regulator body, which indicates gas flow direction, is pointed downstream towards the fryers. The air vent cap is also part of the regulator and should not be removed.
3. If a vent line from the gas pressure regulator is used, it should be installed in accordance with local codes or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-(Latest Edition).

new connections.

B. RegulatorsGas regulators can be adjusted in the field, but no adjustments should be made

unless the regulator is out of adjustment or serious pressure fluctuations are observed.

C. Only qualified service personnel should make adjustments to the regulators.

D. OrificesThe fryer can be ordered to operate on any available gas. The correct

combination gas valve, appropriate burner orifices, and pilot burners are installed at the factory. While the valve can be adjusted in the field, only qualified service personnel should make any adjustments with the proper test equipment.

E. Flexible Couplings, Connectors and Casters:

1. If the fryer is to be installed with flexible couplings and/or quick-disconnect fittings, the installer must use a heavy-duty AGA design-certified commercial flexible connector of at least ¾" NPT (with suitable strain-relief attachments), in compliance with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69-(Latest Edition) and Addenda Z21.69a-(Latest Edition). Quick disconnect devices must comply with the Standard for Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z21.41-(Latest Edition).
Page 20 of the Frymaster *8196329* user manual — CHAPTER 3: INSTALLATION INSTRUCTIONS
Page 20 · click to enlarge
Page 20

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.4 Gas Connections (cont.)

2. For an appliance equipped with casters, the installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69, or Connectors for Moveable Gas Appliances, CAN/CGA-6.16. A quick- disconnect device that complies with the Standard for Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z21.41, or Quick-Disconnect Devices for Use with Gas Fuel, CANI-6.9, must be used. Under no circumstances are the connector and the quick- disconnect device or its associated piping to be used to limit fryer movement.

3. The fryer must be restrained by means independent of the flexible coupling or connector in order to limit the movement of the fryer. Clips are located on the back panel of the fryer for the attachment of restraints.
4. If it is necessary to disconnect the restraint, it must be reconnected after the fryer has been returned to its originally installed position.

Personal injury may result.

F. After hook-up, bleed the gas line of air to ensure that the pilot light will ignite quickly and

evenly.

if required. Failure to use qualified personnel will void the Frymaster warranty. 3.5 Adjustments/Adaptation To Different Gases

A. Proper operation of appliances requires the operator to scrupulously inspect the following:

1. Gas inputs and pressures;
2. Voltage and polarities of electrical power supplies.

B. Frymaster gas fryers are manufactured to use the type of gas and pressure specified on the

rating plate. When changing gas, adaptation must be performed by qualified personnel. Failure to use qualified personnel will void the Frymaster warranty. Nominal "Qn" Heat Input for the YSCFH18G High Efficiency Cool Zone Gas fryer is 25 kW.

Page 21 of the Frymaster *8196329* user manual — GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Page 21 · click to enlarge
Page 21

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.6 Gas Conversion: Procedures

from one gas type to another requires the installation of specific gas-conversion

components.

Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A

GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!

Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as

defined in Section 1.6 of this manual. See below for gas valve illustration when performing the following conversions. Conversion from one gas family to another (e.g. changing from natural gas to propane) requires special components and parts. Contact a Factory Authorized Service Agent for requirements and part numbers. Conversions can only be executed by qualified, factory-authorized personnel.

Pilot pressure adjustment (remove cover screw to access)

Pressure flow adjustment (remove cover screw to access)

Frymaster *8196329* — GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED! diagram (page 21)
Fig. 15

ON/OFF Gas-Cock Knob Pilot gas supply connection.

Regulator Vent · Non-CE Gas Valve

Page 22 of the Frymaster *8196329* user manual — PRONG ON THIS PLUG!
Page 22 · click to enlarge
Page 22

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.7 Electrical Connections

receptacle. DO NOT CUT, REMOVE, OR OTHERWISE BYPASS THE GROUNDING

PRONG ON THIS PLUG!

appliance during a power outage. Refer to the rating plate and wiring diagram located inside the front door. The fryer is equipped with a 120VAC/60Hz system for USA/Canada/Mexico operations. All electrically operated appliances must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code (ANSI/NFPA 70) or the Canadian Electrical Code (CSA C22.2). Do not cut or remove the ground prong from the power cord plug. Do not attempt to use this appliance in a power outage. 3.8 Safety Switches A. Fryer with KFC-1 Computer

This fryer/filter system is equipped with a drain valve safety switch and a frypot float-switch on each of the two-batteried fryers. Drain-valve safety switches de-energize the control circuit during the filter process, thus providing an additional safety feature. Always leave the computer ON when filtering. The KFC-1 computer monitors cooking operations. The computer logs the number of cook sequences and locks out the cook cycle after a preset number is reached. The drain-valve must be opened, the oil must be filtered, and the drain-valve closed before the KFC-1 computer will allow a cook cycle. After filtering, always allow the frypot to refill with oil and heat to setpoint before engaging a cook cycle. See the accompanying KFC-1 SMS Cooking Computer User Manual for more detailed information.

Page 23 of the Frymaster *8196329* user manual — CHAPTER 3: INSTALLATION INSTRUCTIONS
Page 23 · click to enlarge
Page 23

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.8 Safety Switches (cont.) B. Other Fryer/Filter Switches

Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 23)
Fig. 16
1. Drain Valve Microswitch: The computer will display DRAIN OPEN when the drain valve is opened. The computer will lockout, preventing any cooking operation until EXIT/COOL FILTER is pressed.
Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 23)
Fig. 17
Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 23)
Fig. 18

A microswitch is located on the red handle at the drain valve.

2. Float-Switch: Located in the frypot. Designed as a safety switch, it deactivates the gas valve, preventing burner ignition until the oil level extends above the heating tubes.
Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 23)
Fig. 19
3. High-limit Reset: Located in each fryer cabinet under the control panel. This switch is used to reset the high-limit if the cooking medium has reached high temperature safety limits. The high-limit sensor bulb is mounted inside the frypot between the two left-most burner tubes.
Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 23)
Fig. 20

The hi-limit reset is accessible in the fryer cabinet under the controller.

Show 6 more labels / short text on this page
Frypot Front · High-Limit · Float Switch · Temperature · Probe · Probe
Page 24 of the Frymaster *8196329* user manual — CHAPTER 3: INSTALLATION INSTRUCTIONS
Page 24 · click to enlarge
Page 24

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.8 Safety Switches (cont.) C. Filtering: Drain Valve and Oil Return Handles

1. Drain Valve Handle: RED HANDLE. Push the red handle (located in the fryer cabinet) to the right to open the drain valve when filtering. After all oil has drained from the frypot and/or polishing is complete, push the red handle left to close the drain valve. 2. Oil Return Handles: YELLOW LABEL. The oil-return handles to the left and right in the fryer cabinet return oil at the rear of the pot, which flushes oil across the bottom of the vat, washing debris toward the drain. The oil-return handles in the center of the cabinet return oil through the over-the-top system. Ensure the faucet is positioned over the emptied vat before running oil through the over-the-top return system. See Chapter 5 for more information on filtering.

Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 24)
Fig. 21
Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 24)
Fig. 22
Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 24)
Fig. 23
Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 24)
Fig. 24
Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 24)
Fig. 25

Drain valve handles (red). Rear flush

See Chapter 7 for troubleshooting information.

Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 24)
Fig. 26

hot oil will spill and may cause burns.

Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 24)
Fig. 27

disposal unit.

Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 24)
Fig. 28

Over-the-top return handles · handle · Rear flush handle

Page 25 of the Frymaster *8196329* user manual — CHAPTER 3: INSTALLATION INSTRUCTIONS
Page 25 · click to enlarge
Page 25

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.9 Initial Cleaning Before Startup New units are wiped clean with solvents at the factory to remove any visible signs of dirt, oil, and grease remaining from the manufacturing process. Then, they are coated lightly with oil. Wash thoroughly with hot, soapy water to remove any film residue and dust or debris before food preparation. Then, rinse and wipe dry. In addition, wash any accessories shipped with the unit. Close the drain valve completely and remove the crumb screen. Ensure the screws securing the temperature probe to the bracket between heating tubes are tight.

Failure to do so will cause hot oil to splatter and injure the operator. 3.10 Final Preparation

1. The YSCFH18G frypot shortening capacity is approximately 40.5 kg (90 lb).
2. Ensure fryer power switches are OFF.
3. Cooking Oil: Fill the fryer to the bottom OIL LEVEL line scribed into the back of the frypot. Replace the basket support screen.

the heating tubes.

will damage the frypot and increase the potential for flash-point shortening

temperatures and subsequent fire.

4. Solid Shortening: Either pre-melt solid shortening on another appliance first or cut it into small pieces and pack it tightly into the cool zone at the bottom of the frypot. Take care not to disturb the temperature probe or high-limit thermostat. If solid shortening is packed into the frypot, ensure the float switch is in the "up" position. 5. FAST Controller: See the Fast manual for operation of a Fast-equipped fryer.
Page 26 of the Frymaster *8196329* user manual — CHAPTER 3: INSTALLATION INSTRUCTIONS
Page 26 · click to enlarge
Page 26

CHAPTER 3: INSTALLATION INSTRUCTIONS

3.10 Final Preparation (cont.) NOTE: If the float switch is blocked in "down position" with solid shortening, the fryer will not heat. Always ensure that the float switch is in the "up" position when packing solid shortening into frypot.

6. KFC-1 Cooking Computer: Turn computer ON (this also turns the fryer ON if equipped with electronic ignition). The computer will cycle the burners ON and OFF (melt cycle). This is indicated by heat icons located on either side of the KFC-1 product buttons, which will cycle ON and OFF with the fryer. The computer will display LOw until the shortening reaches 180°F (82°C).
Frymaster *8196329* — CHAPTER 3: INSTALLATION INSTRUCTIONS diagram (page 26)
Fig. 29

At 180° F (82°C), the fryer goes into continuous heat mode. The computer will display actual oil temperature until setpoint is reached. At setpoint temperature, the computer will display drop. NOTE: For FAST-equipped fryers, see the Fast manual for operation instructions.

7. After shortening reaches the setpoint temperature, let the burners cycle at least four times, then insert a thermometer or pyrometer near the temperature sensing probe within 1 inch of the temperature probe and approximately 3-in. (7.5-mm) deep into the shortening. When the burners cycle on after the fourth time, the thermometer should read within ± 5°F ( ± 2°C) of the computer temperature setting.
8. When the frypot is filled and the shortening melted, replace the basket-support screen over the heating tubes.

a tight fit and should only be removed for cleaning. For pilot lighting instructions, see Chapter 4. For filtration instructions, see Chapter 5.

Heat Icon Indicators · Product Buttons

Page 27 of the Frymaster *8196329* user manual — 4.1 General Use
Page 27 · click to enlarge
Page 27

CHAPTER 4: DAILY OPERATION

4.1 General Use

1. At opening, always check that the power switch and the computer are OFF. 2. For consistent quality product, convenience, and long-term savings, use a high-quality liquid shortening.
3. If using solid shortening, never melt a block of shortening by placing an entire block in the fryer vessel. Cut it into small pieces and pack it around fryer components.
4. Although 350°F (177°C) is the recommended temperature for most cooking operations, set the fryer at the lowest possible temperature which produces a high quality end product while ensuring maximum life for your oil. 4.2 Start-Up Procedures
1. If the fryer is empty, pour enough oil into the frypot to fill it to the bottom OIL LEVEL line scribed on the rear wall. If solid shortening is used, melt the shortening following procedures in Section 3.10, Final Preparation .

A. Pilot lighting procedure – Electronic Ignition

a. Turn gas "ON."

b. Turn electric power "ON" with the appropriate rocker switch or controller/computer.

c. The ignition module will energize the pilot gas supply and the ignitor. The ignitor

spark will ignite the pilot gas. The presence of the pilot flame is then proven by a flame sensor, which sends a signal to the main gas supply, opening the valve. The operating thermostat or computer/controller controls the fryer after ignition.

out the system. Turn the unit power "OFF" and then back "ON" after power has

been re-established.

d. If the pilot flame fails, the ignition module will shut down and lock out the system.

To restart, turn the electric power "OFF,” wait approximately 5 minutes for the system to recycle itself, and then turn the power "ON" again. Repeat Steps a-c.

Page 28 of the Frymaster *8196329* user manual — CHAPTER 4: DAILY OPERATION
Page 28 · click to enlarge
Page 28

CHAPTER 4: DAILY OPERATION

2. KFC-1 Cooking Computer: Turn the computer ON and ensure at least one LED is lit above a product button (1-9). Select a cooking program as described in the KFC-1 SMS Cooking Computer User Guide.
Frymaster *8196329* — CHAPTER 4: DAILY OPERATION diagram (page 28)
Fig. 30

ON/OFF Buttons

Page 29 of the Frymaster *8196329* user manual — See Chapter 5 for detailed filtration procedures. 4.4 Closing
Page 29 · click to enlarge
Page 29

CHAPTER 4: DAILY OPERATION

4.3 Filtering

Frymaster *8196329* — CHAPTER 4: DAILY OPERATION diagram (page 29)
Fig. 31

(177°C). Ensure all hoses are connected properly and drain handles are in their

proper position prior to operating any switches or valves.

spontaneously combust if left soaking in certain shortening material.

fryer only.

1. The KFC-1 Computer must remain ON during filter operations for proper filter function.
2. Filter the shortening at least once daily or more frequently if cooking is heavy. This assures the longest life possible for the shortening, a better taste to the food being prepared, and minimizes flavors being transferred from batch to batch.
3. If using solid shortening, clear return lines before turning off the filter motor by allowing the pump to run for approximately 15-30 seconds once air bubbles appear in the frypot from the oil return line. Failure to do so increases the likelihood that solid shortening will solidify and clog the lines.

See Chapter 5 for detailed filtration procedures. 4.4 Closing

1. When closing at night, filter shortening in all fryers and drain the filter lines. Cover the open tanks of oil. Turn the computer OFF. 2. When shutting down for periods longer than overnight, drain shortening and clean the frypot thoroughly. After cleaning, discard the shortening or filter it and return it to the frypot. Cover the frypot with the appropriate frypot cover. Turn both the power switch and computer OFF.
Page 30 of the Frymaster *8196329* user manual — 5.1 General
Page 30 · click to enlarge
Page 30

CHAPTER 5: FILTRATION

5.1 General

the inherent hazards of operating a hot oil filtering system, particularly the aspects

of oil filtration, draining, and cleaning procedures. To conduct filter operations with the KFC-1 Cooking Computer installed on the fryer, ALWAYS leave the computer ON when filtering. The computer must sense the drain valves opening and closing in order to allow fryer operation. For consistent product quality, convenience, and long-term savings use a high-quality liquid shortening or vegetable oil. If using solid shortening, always ensure the return lines are clear before turning off the filter pump. Hang any flexible lines up to drain. Solid shortening will solidify as it cools and clog the lines. 5.2 Filter Preparation Assemble filtering tools. These are supplied with the filter starter kit (at right):

Frymaster *8196329* — 5.1 General diagram (page 30)
Fig. 32 · 5.1 General
  • L-shaped Teflon Brush: Used to clean frypot sides, heating tubes, and to dislodge sediment during filtration or oil change.
  • Clean-out Rod: Used to dislodge heavy debris in the drain tube (when needed).
  • Filter Powder.
  • Filter Paper.

The following tools are not required, but are recommended to make the filtering task easier.

  • Measuring Cup: Used to measure filter powder.
  • Stainless Steel Crumb Scoop: Used to remove large debris from oil prior to filtering. NOTE: Always wear oil-resistant, insulated gloves and/or protective gear when working with hot oil.
Page 31 of the Frymaster *8196329* user manual — CHAPTER 5: FILTRATION
Page 31 · click to enlarge
Page 31

CHAPTER 5: FILTRATION

5.2 Filter Preparation (cont.) 1. Put on protective gear/gloves. Pull the filter pan out of the filter cabinet. Remove cover. 2. Remove crumb screen. If crumbs are present in the crumb screen, empty the screen into a fireproof container. Thoroughly wash the screen in hot, soapy water, rinse, then dry.

Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 31)
Fig. 33
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 31)
Fig. 34
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 31)
Fig. 35
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 31)
Fig. 36
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 31)
Fig. 37
3. Remove the hold-down ring.
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 31)
Fig. 38
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 31)
Fig. 39
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 31)
Fig. 40
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 31)
Fig. 41
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 31)
Fig. 42
4. Remove and discard old filter paper sheet from the filter pan.
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 31)
Fig. 43
Page 32 of the Frymaster *8196329* user manual — CHAPTER 5: FILTRATION
Page 32 · click to enlarge
Page 32

CHAPTER 5: FILTRATION

5. Remove the filter screen from the bottom of the pan.
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 44
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 45
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 46
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 47
6. Thoroughly clean the pan and all pan components as described for the crumb screen (Step 2 ).
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 48
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 49
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 50
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 51
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 52
7. Inspect the pickup tube and ensure vent hole is open and free of shortening/debris.
8. Replace filter screen and drape one sheet of filter paper across the filter pan. The filter screen must be installed prior to filter paper placement or the filter won’t operate correctly.
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 53
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 54
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 55
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 56
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 32)
Fig. 57
Page 33 of the Frymaster *8196329* user manual — CHAPTER 5: FILTRATION
Page 33 · click to enlarge
Page 33

CHAPTER 5: FILTRATION

9. Reinstall the hold-down ring. Ensure filter paper is properly aligned under the hold-down ring. Press the filter paper into place with the hold-down ring, ensuring the paper laps against the walls of the filter pan.
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 33)
Fig. 58
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 33)
Fig. 59
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 33)
Fig. 60
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 33)
Fig. 61
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 33)
Fig. 62
10. Sprinkle 1 cup (8 ounces/227 grams) of filter powder evenly over the paper. Use a measuring cup or scoop to evenly distribute filter powder over the filter sheet.
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 33)
Fig. 63
11. Replace the crumb screen . Ensure crumb screen is cleaned throughout the workday. 12. Return pan cover to the filter pan. 13. Return filter pan to fryer cabinet, ensuring that the two drainpipe extensions are directly over the opening in the filter pan cover.
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 33)
Fig. 64
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 33)
Fig. 65
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 33)
Fig. 66
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 33)
Fig. 67
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 33)
Fig. 68

5.3 Filter Operations NOTE: When left and right are indicated, refer to the operator’s left and right.

avoid a serious burn caused by careless handling. The oil to be filtered is at or near

350°F (177°C). Ensure all hoses are connected properly and drain handles are in their proper position before operating any switches or valves. Wear all appropriate

safety equipment when draining and filtering oil.

Page 34 of the Frymaster *8196329* user manual — CHAPTER 5: FILTRATION
Page 34 · click to enlarge
Page 34

CHAPTER 5: FILTRATION

Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 34)
Fig. 69

hot oil will spill and may cause burns.

Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 34)
Fig. 70

disposal unit.

Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 34)
Fig. 71

overflow and spillage of hot oil.

Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 34)
Fig. 72

maximum fill line located on the container. 1. Remove large debris floating in the oil. NOTE: Always heat oil to operating temperature before filtering.

Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 34)
Fig. 73

Remove large debris from frypot prior to filtering.

Page 35 of the Frymaster *8196329* user manual — CHAPTER 5: FILTRATION
Page 35 · click to enlarge
Page 35

CHAPTER 5: FILTRATION

5.3 Filter Operations (cont.) 2. Remove the support grid from the frypot using the clean-out rod. Stir the oil with the L-shaped Teflon brush to suspend debris prior to draining. 3. Open the fryer drain valve by pushing the red handle (under the frypot to be filtered) to the right until it is completely open. Continue stirring the oil.

Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 35)
Fig. 74

Removing support grid from frypot prior to draining.

Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 35)
Fig. 75
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 35)
Fig. 76
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 35)
Fig. 77

Push the red handle right to open drain valve. Oil will start to drain into filter pan.

Page 36 of the Frymaster *8196329* user manual — CHAPTER 5: FILTRATION
Page 36 · click to enlarge
Page 36

CHAPTER 5: FILTRATION

5.3 Filter Operations (cont.) 4. Use the L-shaped brush to scrub the frypot, and to assist in sediment removal. Brush the frypot sides and between the tubes to remove debris. Use the clean-out rod to clear the drain if necessary. 5. Open the oil return valve by pushing one of the oil return valves to the left. Oil-return handles on the far sides of the cabinet return oil to the frypot through rear ports, which flush debris from the bottom of the frypot. The two return valve handles in the center of the cabinet return oil through the top- mounted faucet. Ensure the faucet is over the drained frypot before attempting to return oil through the faucet.

Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 36)
Fig. 78
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 36)
Fig. 79

Use the L-shaped brush to loosen debris as oil drains from the frypot.

hot oil will spill and may cause burns.

Page 37 of the Frymaster *8196329* user manual — CHAPTER 5: FILTRATION
Page 37 · click to enlarge
Page 37

CHAPTER 5: FILTRATION

5.3 Filter Operations (cont.) 6. Close the red drain valve by pushing the handle to the right until it stops. The fryer will not operate unless the computer senses a closed drain microswitch circuit. Leave the oil return handle (yellow label) open to allow pump to run and frypot to fill with filtered oil. 7. When filtering is complete:

Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 37)
Fig. 80
  • Rear Flush Oil Return: Allow the filter to pump bubbles into the fryer for 15-30 seconds to ensure the oil return lines are clear of oil.
  • Over-the-top Oil Return: Allow the faucet to sputter for 15-30 seconds to ensure the oil return lines are clear of oil. 8. Turn off the filter by turning the oil return handle to the left, into the CLOSED position. This closes the oil return valve under the filtered frypot and stops the filter pump motor.
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 37)
Fig. 81
Frymaster *8196329* — CHAPTER 5: FILTRATION diagram (page 37)
Fig. 82

Empty contents of the crumb screen into a fireproof container immediately after filtering is complete.

Page 38 of the Frymaster *8196329* user manual — CHAPTER 5: FILTRATION
Page 38 · click to enlarge
Page 38

CHAPTER 5: FILTRATION

9. Repeat Steps 1 and 2 in Section 5.2. Remove crumb screen and empty debris into a fireproof container. If possible, wash all filter pan components in hot, soapy water. Rinse and dry thoroughly (Section 5.2, Step 7). If not, the filter pan should be thoroughly cleaned at the close of each day, as previously described. Filtration system troubleshooting information can be found in Chapter 7.
Page 39 of the Frymaster *8196329* user manual — CHAPTER 6: PREVENTATIVE MAINTENANCE
Page 39 · click to enlarge
Page 39

CHAPTER 6: PREVENTATIVE MAINTENANCE

Well-maintained equipment operates more efficiently and lasts longer. Keep the fryer clean during the day and thoroughly clean it at the end of each day.

Frymaster *8196329* — CHAPTER 6: PREVENTATIVE MAINTENANCE diagram (page 39)
Fig. 83

DANGER Never attempt to clean the fryer during the cooking process or when the frypot is filled with hot oil. If water comes in contact with oil heated to cooking temperature, it will cause spattering of the oil, which can result in severe burns to nearby personnel. 6.1 Daily Wash all removable parts. Clean all exterior surfaces. Do not use cleansers, steel wool, or any other abrasive material on stainless steel. Filter the oil and replace it if necessary. Filter oil more often under heavy use conditions (e.g., frying heavily breaded products).

Frymaster *8196329* — CHAPTER 6: PREVENTATIVE MAINTENANCE diagram (page 39)
Fig. 84

of time the cleaner remains on the food-contact surfaces.

damage will result if water is allowed into the system, and all applicable warranties

will be voided. 6.2 Weekly Completely drain the frypot into either the filter or a steel container. Do not use a plastic bucket or glass container.

  • Clean the frypot with a high grade cleaner or hot water and a strong detergent.
  • Close the drain valve and refill with either the cleaning solution or water and detergent.
  • Scrub frypot walls and heating tubes. Then drain frypot and rinse in clear water.
  • Once cleaning is completed, drain, rinse, and dry thoroughly.
  • Refill with shortening as directed in Section 3.10 of this manual.
Page 40 of the Frymaster *8196329* user manual — CHAPTER 6: PREVENTATIVE MAINTENANCE
Page 40 · click to enlarge
Page 40

CHAPTER 6: PREVENTATIVE MAINTENANCE

6.3 Periodic/Annual This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program. Frymaster and Dean recommend that a factory authorized service technician should inspect this appliance at least annually, as follows:

  • Inspect the cabinet inside-and-out, front-and-rear for excessive oil build-up.
  • Verify that debris or accumulations of solidified oil or shortening do not obstruct the flue opening.
  • Verify that burners and associated components (e.g., gas valves, pilot assemblies, ignitors) are in good condition and functioning properly. Inspect all gas connections for leaks and verify that all connections are properly tightened.
  • Verify that the burner manifold pressure matches the pressure specified on the fryer’s rating plate.
  • Verify that the temperature and high-limit probes are connected, tightened, and functioning properly, and that mounting hardware and probe guard are present and properly installed.
  • Verify that component box components (e.g., computer/controller, transformers, relays, interface boards) are in good condition and free of oil build-up and other debris. Inspect the component box wiring and verify that connections are tight and that wiring is in good condition.
  • Verify that all safety features (e.g., drain safety switches, reset switches) are present and functioning properly.
  • Verify that the frypot/cookpot is in good condition and free of leaks and that the frypot/cookpot insulation is in serviceable condition. Verify that the frypot tube diffusers are present and in good condition (i.e. no visible deterioration or damage).
  • Verify that wiring harnesses and connections are tight and in good condition.

Built-in Filtration:

  • Inspect all oil-return and drain lines for leaks and verify that all connections are tight.
  • Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof container and cleaned daily.
  • Verify that all O-rings and seals, including those on quick-disconnect fittings, are present and in good condition. Replace O-rings and seals if worn or damaged.
Page 41 of the Frymaster *8196329* user manual — CHAPTER 6: PREVENTATIVE MAINTENANCE
Page 41 · click to enlarge
Page 41

CHAPTER 6: PREVENTATIVE MAINTENANCE

6.3 Periodic/ Annual (cont.) Check filtration system integrity as follows:

  • With the filter pan empty, place each oil return handle in the OPEN position, one at a time. Using rear flush oil return, verify that the pump activates and that bubbles appear in the oil of the associated frypot. Using over-the-top oil return, verify that the pump activates and that the faucet sputters.
  • Close all oil return valves (i.e., place all oil return handles in the CLOSED position). Verify proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot and the over-the-top faucet should not sputter.
  • Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to 350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the OPEN position. Allow all oil to return to the frypot. The frypot should refill in no more than 2 minutes and 30 seconds. Move the oil return handle to the CLOSED position when the oil return lines are clear of oil (indicated by bubbles in the oil in the frypot or sputtering in the over-the-top faucet). To ensure good fryer health and a safe environment, the fryer should be checked and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program. 6.4 Stainless Steel All stainless steel fryer outer parts should be wiped regularly with hot, soapy water during the day and with a liquid cleaner designed for this material at the end of each day.
  • Do not use steel wool, abrasive cloths, cleansers, or powders!
  • Do not use a metal knife, spatula, or any other metal tool to scrape stainless steel! Scratches are almost impossible to remove.
  • If it is necessary to scrape the stainless steel to remove any encrusted materials, soak the area to loosen the material and use a wood or nylon scraper only.
Page 42 of the Frymaster *8196329* user manual — CHAPTER 7: TROUBLESHOOTING
Page 42 · click to enlarge
Page 42

CHAPTER 7: TROUBLESHOOTING

7.1 Introduction This section provides an easy reference guide to some of the common problems that may occur during the operation of this equipment. The troubleshooting guides that follow are intended to help correct, or at least accurately diagnose, problems with this equipment. Although this chapter covers the most common problems reported, you may encounter problems, which are not addressed. In such instances, the Frymaster/Dean Technical Service staff will make every effort to help you identify and resolve the problem. When troubleshooting a problem, always use a process of elimination starting with the simplest solution and working through to the most complex. Never overlook the obvious – anyone can forget to plug in a cord or fail to close a valve completely. Most importantly, always try to establish a clear idea of why a problem has occurred. Part of any corrective action involves taking steps to ensure that it doesn’t happen again. If a controller malfunctions because of a poor connection, check all other connections, too. If a fuse continues to blow, find out why. Always keep in mind that the failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system. Before calling a service agent or the Frymaster/Dean HOTLINE (1-800-551- 8633):

  • Verify that electrical cords are plugged in and that circuit breakers are on;
  • Verify that frypot drain valves are fully closed;
  • Verify that gas line is properly connected.
Frymaster *8196329* — CHAPTER 7: TROUBLESHOOTING diagram (page 42)
Fig. 85

qualified service personnel. The equipment should be unplugged when servicing,

system. Open flame increases the chance of fire and operator injury.

Page 43 of the Frymaster *8196329* user manual — CHAPTER 7: TROUBLESHOOTING
Page 43 · click to enlarge
Page 43

CHAPTER 7: TROUBLESHOOTING

7.2 Fryer Troubleshooting For FAST-equipped fryers, consult the FAST controller manual. These steps apply to the KFC-1 SMS computer only.

1. Check wall circuit breakers. Reset, if needed. 2. Check fryer connection to external power source. 3. Disconnect fryer from power supply. 4. A power surge or outage may have temporarily locked out computer. If the fryer still fails to turn ON when the ON/OFF button is pressed, contact an authorized service agent.

Computer fails to turn ON when ON/OFF button is pressed.

1. Ensure float-switch is not stuck in "down" position. Contact an authorized service technician for service if floatswitch is defective. 2. If the KFC-1 SMS computer displays HELP, reset high-limit thermostat (located in the fryer cabinet under the control panel). Contact an authorized service technician for service if highlimit will not reset .

7.2.2 Computer is ON, but the gas valves fail to energize.

Ensure at least one product button is lit on the computer. If not, press product buttons until one button is lit. 7.2.3 Computer is ON but fryer fails to heat.

Ensure setpoint assigned to product is accurate.

Page 44 of the Frymaster *8196329* user manual — CHAPTER 7: TROUBLESHOOTING
Page 44 · click to enlarge
Page 44

CHAPTER 7: TROUBLESHOOTING

7.2 Fryer Troubleshooting (cont.)

1. Turn fryer ON. 2. Select a product number and allow the fryer to heat for approximately 30 minutes to stabilize shortening temperature at desired setpoint. 3. Place a thermometer near the temperature sensing probe within 1 inch of the temperature probe and approximately 3- in. (75-mm) deep into the shortening. (see illustration, Page 7-3). 4. Press the KFC-1 SMS computer temperature button to check the frypot temperature. Press the computer temperature button twice to view setpoint temperature for the product number chosen. 5. The thermometer temperature should be within ±10°F (±5°C) of the KFC-1 SMS computer display temperature.

7.2.4 Frypot temperature differs from the computer setpoint temperature.

Yes: System is maintaining temperature properly.

Page 45 of the Frymaster *8196329* user manual — CHAPTER 7: TROUBLESHOOTING
Page 45 · click to enlarge
Page 45

CHAPTER 7: TROUBLESHOOTING

7.2 Fryer Troubleshooting (cont.)

No: Ensure the probe tip is ⅛" from the top of the burner tubes (see illustration). If the probe adjustment is correct, the computer probe circuit may be faulty. If probe adjustment is incorrect, it will require adjustment. 6. Contact your authorized service agent if any of the following occurs during this test:

a. Computer probe circuit is suspected

as faulty. b. Temperature probe needs adjustment.

c. KFC-1 SMS computer fails to call

for heat during the calibration test.

Show 7 more labels / short text on this page
Frypot Front · Probe Temperature · High-Limit · Probe · Temperature Probe · Probe Bracket · Burner Tube
Page 46 of the Frymaster *8196329* user manual — CHAPTER 7: TROUBLESHOOTING
Page 46 · click to enlarge
Page 46

CHAPTER 7: TROUBLESHOOTING

7.2 Fryer Troubleshooting (cont.)

1. KFC-1 SMS computer was turned OFF while draining frypot. 2. Close drain valve. Turn KFC-1 SMS computer OFF and ON again. Computer display will read ON. 3. Open drain valve. The KFC-1 SMS computer display will read DRAIN OPEN. After 30 seconds the computer display will read FILL. 4. Close drain valve. 5. Fill frypot with shortening. Press EXIT/COOL FILTER when ready to cook. 6. If the KFC-1 SMS computer message DRAIN OPEN remains after Steps 1- 4, contact an authorized service agent. Possible malfunctions are:

7.2.5 DRAIN OPEN message remains after closing drain valve.

a. Drain microswitch may be faulty.

b. Drain circuit is suspect.

c. KFC-1 SMS computer is suspect.

1. The motor thermal overload has tripped. If the thermal overload trips, wait approximately 45 minutes. Press the button on the end of the filter motor. 2. If you have to do this repeatedly, stop resetting the overload and contact an authorized service agent. NOTE: This is usually caused by allowing large particles of food to enter the pump during filtering. Ensure that the filter paper and crumb screen are properly in place.

7.2.6 Pump motor won’t start or stops during filtering.

Page 47 of the Frymaster *8196329* user manual — CHAPTER 7: TROUBLESHOOTING
Page 47 · click to enlarge
Page 47

CHAPTER 7: TROUBLESHOOTING

Fryer Troubleshooting (cont.)

A. Main burner will not ignite; no gas is

present at main burner.

1. Check that float switch is not stuck in the "down" position.
2. Check and reset the high-limit switch.
3. The combination gas valve and/or electronic ignition system may be defective; contact an authorized service technician for service. B. Main burner flames are small and

appear lazy; shortening does not come up to temperature quickly. Contact an authorized service technician for service. C. Fryer will not reach setpoint temperature and/or runs erratically.

7.2.7 Main burner malfunctions.

1. Incorrect location or adjustment of sensor probe. Contact an authorized service technician for service.
2. Defective temperature sensor. Contact an authorized service technician for service. D. Fryer shortening temperature cannot be

controlled; fryer runs at high-limit temperature. Possible causes are:

1. Defective operating thermostat. Contact an authorized service technician for service. 2. Defective temperature probe. Contact an authorized service technician for service.
Page 48 of the Frymaster *8196329* user manual — CHAPTER 7: TROUBLESHOOTING
Page 48 · click to enlarge
Page 48

CHAPTER 7: TROUBLESHOOTING

7.3 Filtration System Troubleshooting

  • Return valve not fully opened.
  • Tripped circuit breaker.
  • Incorrect or no line voltage.
  • Failed or misadjusted return microswitch.

start.

Pump stops during filtering process. Motor

  • Allow motor to cool for at least 45 minutes and then press thermal overload switch on motor.

is hot.

  • Move filter handle to OFF. Allow oil to cool then empty pan. Verify filter paper and screen are clean and properly installed. Refill pan and restart process.

Pump stops and motor is

cool.

  • Reset thermal overload.
  • Verify wiring harness is properly connected; a damaged harness should be replaced by a FASC.
  • Pump is blocked. Call FASC for service.
  • Filter pan suction tube is blocked. Use a thin, flexible wire to unclog.
  • Motor or 24 VAC transformer failed; call for service.

Pump starts and abruptly

stops.

  • Verify O-rings on pan outlet are present and in good condition.
  • Verify paper and screen have been properly installed.

erratic.

  • Solidified oil or sediment is likely clogging the return line. Clear line.

frypot.

After filtering, fryer does not

  • Verify drain valve is fully closed.

operate properly.

Show 4 more labels / short text on this page
Pump won't · Pumping is · Oil not being · returned to
Page 49 of the Frymaster *8196329* user manual — CHAPTER 7: TROUBLESHOOTING
Page 49 · click to enlarge
Page 49

CHAPTER 7: TROUBLESHOOTING

7.4 Wiring Diagrams

Page 50 of the Frymaster *8196329* user manual — CHAPTER 7: TROUBLESHOOTING
Page 50 · click to enlarge
Page 50

CHAPTER 7: TROUBLESHOOTING

Fast-Equipped Control and Filter Circuit

Frymaster *8196329* — CHAPTER 7: TROUBLESHOOTING diagram (page 50)
Fig. 86
Page 51 of the Frymaster *8196329* user manual — CHAPTER 7: TROUBLESHOOTING
Page 51 · click to enlarge
Page 51

CHAPTER 7: TROUBLESHOOTING

KFC-1 Equipped Control and Filter Circuit

Frymaster *8196329* — CHAPTER 7: TROUBLESHOOTING diagram (page 51)
Fig. 87
Page 52 of the Frymaster *8196329* user manual — 1-800-551-8633 OCT 2008
Page 52 · click to enlarge
Page 52
Frymaster *8196329* — 1-800-551-8633 OCT 2008 diagram (page 52)
Fig. 88

Frymaster, L.L.C., 8700 Line Avenue, Shreveport, Louisiana 71106

TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 FAX (Call Center) 1-318-219-7135

Price$10.00 PRINTED IN THE UNITED STATES SERVICE HOTLINE

1-800-551-8633 OCT 2008

819-6329

Ask about the Frymaster *8196329*

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster *8196329*

Be the first to ask — other owners or our team will answer.

Original document

Frymaster *8196329* manual PDF

52 pages·1.1 MB·Fryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…