Instruction/ maintenance manual of the product YSCF14G Frymaster
Go to page of 26
Frymaster and Dean, members of the Commercial Food Equipment Service Associatio n, recommend usi ng CFESA Ce rtified Technici ans. www.frymaster.com 24-Hour Service Hotline 1-800-551-8633 YSCF14G Seri.
Please read all sections of this manual and retain for future reference. NOTICE This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster/Dean Authorized Service Agency (ASA) or other qualified professional should perform installation, maintenance, and repairs.
DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains.
YSCF14G INSTALLATION & OPERATION MANUAL TABLE OF CONTENTS Page # 1. Installation …………………………………………………………………………………1-1 2. Fryer Operations …………………………………………………………………….
YSCF14G SERIES GAS FRYERS CHAPTER 1: INSTALLATION 1-1 1.1 Gas Connections DANGER Before connecting new pipe to this appliance the pipe must be blown out thoroughly to remove all foreign material. Foreign mate rial in the burner a nd gas controls will cause improper and dangerous operation.
YSCF14G SERIES GAS FRYERS CHAPTER 1: INSTALLATION 1-2 1.1 Gas Connections (cont.) DANGER All connections must be sealed with a joint compound suitable for the gas being used and all connections must be tested with a solution of soapy water before lighting any pilots.
YSCF14G SERIES GAS FRYERS CHAPTER 1: INSTALLATION 1-3 1.1 Gas Connections (cont.) E. Manifold Pressure : Only qualified personnel should check the manifo ld pressure with a manometer . 1. Check the rating plate for manifold gas pressu res. Natural gas units norm ally require 4" W.
YSCF14G SERIES GAS FRYERS CHAPTER 1: INSTALLATION 1-4 1.1 Gas Connections (cont.) 3. If disconnection of the restrain t is necessary, this restraint must be reconnected after the fryer has been returned to its originally installed position. J. After hook-up, bleed the gas line of air to ensure that the pilot light will ignite quickly.
YSCF14G SERIES GAS FRYERS CHAPTER 2: FRYER OPERATIONS 2-1 2.1 Initial Start-up WARNING The on-site supervisor is responsible for ensuring that operators are made a ware of the inherent hazards of operating a hot oil fry ing system, particularly the aspects of system operation, oil filtration, draining and cleaning procedures.
YSCF14G SERIES GAS FRYERS CHAPTER 2: FRYER OPERATIONS 2-2 2.2 Final Preparation WARNING Do not go near the area directly over the flue outlet while the fryer is operating. Always wear oil-proof, insu lated gloves when w orking with the fryer filled with hot oil.
YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-1 WARNING Drawings and photos used in this manual are intended to illu strate operational, cleaning and technical procedures and ma y not conform to on-site management operational procedures.
YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-2 3.1 General Frymaster YSCF14G Series gas fryers come equipped with a built-in filtrat ion system. Photos used in the procedural illustrations may dif fer slightly from the filter unit that came with the f rying system.
YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-3 Assemble the filter as f ollows: 1. Place the support grid in th e bottom of filter pan. 2. Center the filter pad in th e filter pan with the notch toward the pick-up tube. 3. Position the hold-down ring on the filter pan with the notch toward the pick-up tube.
YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-4 3.2.2 Installing the Filter Slide the filter inside the fryer cabinet. Ensure the male-fem ale slip-fitting coupling is fully engaged. 3.3 Daily Filtration Operation DANGER Use caution and wear proper protect ive clothing.
YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-5 3.3.2 Filtering Tools Assemble tools to be used for filtering. These ar e supplied with the filter starter kit included with the fryer/filt.
YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-6 3.4 Operating the Filter (cont.) DANGER Do not drain more than one frypot at a ti me into th e built-in fi ltration unit to avoid overflow and spillage of hot oil/shortening.
YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-7 2. Remove fry baskets from frypot. Prior to filtering, skim any large debris from the shortening/oil. Use extreme caution, as shortening/oil is at or near operating temperature [~350°F (~177°C)].
YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-8 Push a blue-handled drain lever left to right to drain a frypot. Drain only one frypot at a time. Twis t a red- handled filter lever left to right to start the filter pump. 3.4.2 Filter Operation (cont.
YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-9 3.4.2 Filter Operation (cont.) 6. Oil will begin to pump from the f ilter pan into the frypot. If the frypot tubes, sides and bottom have sediment deposits, clean the frypot with the cleaning brush included with the fryer.
YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-10 3.4.2 Filter Operation (cont.) 9. After all oil is pumped back into the frypot, bubbles form, indicating ai r in the oil return lines. Allow the oil to bubble for 10-15 seconds to ensure all oil is evacuated from the return lines.
YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-11 3.4.2 Filter Operation (cont.) 12. Do not allow crumbs to accumulate in the crumb tray. The crumb tray MUST be emptied into a fireproof container at the end of frying operations EACH day (see DANGER statement below).
YSCF14G SERIES GAS FRYERS CHAPTER 4: COMPUTER OPERATION 4–1 NOTE: See the related YUM computer manual (819-61 33) for programming instructions. Launch Cook Cycle 1: Press a lane key. 2 :SELP (Select Product) appears in the window above the pressed button.
YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-1 5.1 General DANGER Never attempt to clean the fryer during th e cooking process or when the frypot is filled with hot oil/shortening.
YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-2 5.4 Periodic/Annual This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program.
YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-3 5.4 Periodic/Annual (cont.) Built-in Filtration (cont.): • Check filtration system integr ity as follows: − With the filter pan empty, place each oil return handle, one at a time, in the ON position.
Shipping Address: 8700 Line Av enue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-31 8-219 -7140 FAX (Tech Support) 1-318-219-7135 JULY 09 PRINTED IN THE UNITED STATES SERVICE HOTLINE .
An important point after buying a device Frymaster YSCF14G (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Frymaster YSCF14G yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Frymaster YSCF14G - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Frymaster YSCF14G you will learn all the available features of the product, as well as information on its operation. The information that you get Frymaster YSCF14G will certainly help you make a decision on the purchase.
If you already are a holder of Frymaster YSCF14G, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Frymaster YSCF14G.
However, one of the most important roles played by the user manual is to help in solving problems with Frymaster YSCF14G. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Frymaster YSCF14G along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center