EN
Frymaster logo
Official user manual

Frymaster YSCF14G

26 pages·680 KB·Fryer·PDF·ENDEFRITNLJA
Frymaster YSCF14G
Table of Contents 28 sections YSCF14G Series Gas Fryers Installation & Operation Manual · JULY 09 · *8196132* · NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS · … ShowHide
Page 1 of the Frymaster YSCF14G user manual — *8196132*
Page 1 · click to enlarge
Page 1
Frymaster YSCF14G — YSCF14G Series Gas Fryers Installation & Operation Manual diagram (page 1)
Fig. 1 · YSCF14G Series Gas Fryers Installation & Operation M…

YSCF14G Series Gas Fryers Installation & Operation Manual

Frymaster YSCF14G — YSCF14G Series Gas Fryers Installation & Operation Manual diagram (page 1)
Fig. 2 · YSCF14G Series Gas Fryers Installation & Operation M…
Frymaster YSCF14G — YSCF14G Series Gas Fryers Installation & Operation Manual diagram (page 1)
Fig. 3 · YSCF14G Series Gas Fryers Installation & Operation M…
Frymaster YSCF14G — YSCF14G Series Gas Fryers Installation & Operation Manual diagram (page 1)
Fig. 4 · YSCF14G Series Gas Fryers Installation & Operation M…

YSCF14G Series with Built-In Filtration

Frymaster YSCF14G — YSCF14G Series Gas Fryers Installation & Operation Manual diagram (page 1)
Fig. 5 · YSCF14G Series Gas Fryers Installation & Operation M…

Frymaster and Dean, members of the Commercial Food Equipment Service Association, recommend using CFESA Certified Technicians.

JULY 09

www.frymaster.com 24-Hour Service Hotline 1-800-551-8633

*8196132*

Page 2 of the Frymaster YSCF14G user manual — CANADA
Page 2 · click to enlarge
Page 2

Please read all sections of this manual and retain for future reference.

Frymaster YSCF14G — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS diagram (page 2)
Fig. 6

or repairs by unqualified personnel may void the manufacturer’s warranty.

the country and/or region in which the appliance is installed.

technical procedures and may not conform to onsite management operational procedures.

NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS

U.S.

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept

any interference received, including interference that may cause undesired operation. While

this device is a verified Class A device, it has been shown to meet Class B limits.

CANADA

This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set

out by the ICES-003 standard of the Canadian Department of Communications.

Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communications du Canada.

Frymaster YSCF14G — CANADA diagram (page 2)
Fig. 7

service instructions thoroughly before installing or servicing this equipment. Only qualified

service personnel may convert this appliance to use a gas other than that for which it was

Page 3 of the Frymaster YSCF14G user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 3 · click to enlarge
Page 3
Frymaster YSCF14G — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS diagram (page 3)
Fig. 8

anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all

from slips or contact with the hot oil.

other appliance.

Frymaster YSCF14G — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS diagram (page 3)
Fig. 9

must be posted in a prominent location. This information can be obtained from the local gas

company or gas supplier.

EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE

LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH

ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.

at the end of frying operations each day. Some food particles can spontaneously combust if left

soaking in certain shortening material.

the strip, adversely affecting its fit. It is designed for a tight fit and should only be removed for

cleaning.

Page 5 of the Frymaster YSCF14G user manual — 1.1 Gas Connections
Page 5 · click to enlarge
Page 5

YSCF14G SERIES GAS FRYERS

CHAPTER 1: INSTALLATION

1.1 Gas Connections

Frymaster YSCF14G — 1.1 Gas Connections diagram (page 5)
Fig. 10 · 1.1 Gas Connections

to remove all foreign material. Foreign material in the burner and gas controls will

cause improper and dangerous operation. NATIONAL CODE REQUIREMENTS This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug Administration. This equipment is manufactured to use the type of gas specified on the rating plate attached to the door. Connect equipment stamped "NAT" only to natural gas and that stamped "PRO" only to LP (Propane) gas.

Frymaster YSCF14G — 1.1 Gas Connections diagram (page 5)
Fig. 11 · 1.1 Gas Connections

Installation shall be made with a gas connector that complies with national and local codes.

Quick disconnect devices, if used, shall likewise comply with national and local codes.

plate located on the back of the fryer door.

Frymaster YSCF14G — 1.1 Gas Connections diagram (page 5)
Fig. 12 · 1.1 Gas Connections

local gas company or FASC should be contacted immediately to rectify the problem.

A. The gas supply (service) line must be the same size or greater than the fryer inlet line. This

fryer is equipped with a 3/4" (22 mm) male inlet. The gas supply line must be sized to accommodate all the gas-fired equipment that may be connected to that gas supply. Consult your contractor, gas company, supplier, or other knowledgeable authorities.

Recommended Gas Supply Line Sizes Gas TypesNumber of Fryers 12 to 34 or more (*) Natural Gas3/4" (22 mm)1" (28 mm)1-1/4" (35 mm) Propane Gas1/2" (15 mm)3/4" (22 mm)1" (28 mm) (*) When exceeding 18 feet (6 meters) for a configuration of more than four fryers, it is necessary to provide a 1 1/4" (33 mm) rigid gas connection.
Frymaster YSCF14G — 1.1 Gas Connections diagram (page 5)
Fig. 13 · 1.1 Gas Connections
Page 6 of the Frymaster YSCF14G user manual — YSCF14G SERIES GAS FRYERS
Page 6 · click to enlarge
Page 6

YSCF14G SERIES GAS FRYERS

CHAPTER 1: INSTALLATION

1.1 Gas Connections (cont.)

Frymaster YSCF14G — YSCF14G SERIES GAS FRYERS diagram (page 6)
Fig. 14

used and all connections must be tested with a solution of soapy water before

Never use matches, candles, or any other ignition source to check for leaks. If gas

odors are detected, shut off the gas supply to the appliance at the main shut-off

valve and immediately contact the local gas company or an authorized service

agency for service.

Frymaster YSCF14G — YSCF14G SERIES GAS FRYERS diagram (page 6)
Fig. 15
B. Rigid ConnectionsCheck any installer-supplied intake pipe(s) and clean threading chips, or

any other foreign matter before installing into a service line. If the intake pipes are not clear of all foreign matter, the orifices will clog when gas pressure is applied. Seal pipe joints with a sealant resistive to LP gas. When using thread compound on gas piping, use very small amounts and only on male threads. Use a pipe thread compound that is not affected by the chemical action of LP gases. DO NOT apply thread compound to the first two pipe threads—doing so will cause clogging of the burner orifices and control valve. C. Manual shut-off valve: This gas service supplier-installed valve must be installed in the gas

service line ahead of the fryers in the gas stream and in a position where it can be reached quickly in the event of an emergency.

D. Regulating Gas PressureThe fryer and shut-off valve must be disconnected from the gas

supply during any pressure testing of the system.

1. External gas regulators are not normally required on this fryer. A safety control valve protects the fryer against pressure fluctuations. If the incoming pressure is in excess of ½ PSI (3.45 kPa/35 mbar), a step-down regulator will be required .
Frymaster YSCF14G — YSCF14G SERIES GAS FRYERS diagram (page 6)
Fig. 16

line if the test pressure is ½ PSI [3.45 kPa (14 inches W.C.)] or greater to avoid

damage to the fryer’s gas piping and gas valve(s).

Page 7 of the Frymaster YSCF14G user manual — YSCF14G SERIES GAS FRYERS
Page 7 · click to enlarge
Page 7

YSCF14G SERIES GAS FRYERS

CHAPTER 1: INSTALLATION

1.1 Gas Connections (cont.)

E. Manifold PressureOnly qualified personnel should check the manifold pressure with a

manometer.

1. Check the rating plate for manifold gas pressures. Natural gas units normally require 4" W.C., and propane units normally require 11" W.C. gas pressure.
2. Double check the arrow forged into the bottom of the regulator body, which indicates gas flow direction. It should point downstream towards the fryers. The air vent cap is also part of the regulator and should not be removed.
3. If a vent line from the gas pressure regulator is used, it should be installed in accordance with local codes or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-(latest edition).

new connections.

F. Regulators can be adjusted in the field, but it is recommended that they not be tampered with

unless the part is known to be out of adjustment or serious pressure fluctuations are found to exist and can be solved no other way.

G. Only qualified service personnel should make adjustments to the regulators.

H. OrificesThe fryer can be configured to operate on any available gas. The correct safety

control valve, appropriate gas orifices, and pilot burner are installed at the factory. While the valve can be adjusted in the field, only qualified service personnel should make any adjustments with the proper test equipment.

I. Flexible Couplings, Connectors and Casters:

1. If the fryer is to be installed with flexible couplings and/or quick-disconnect fittings, the installer must use a heavy-duty AGA design-certified commercial flexible connector of at least 3/4" NPT (with suitable strain reliefs), in compliance with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69-(latest edition) and Addenda Z21.69a-(latest edition). Quick disconnect devices must comply with the Standard for Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z21.41-(latest edition).

injury may result. 2. The fryer must be restrained by means independent of the flexible coupling or connector in order to limit the movement of the fryer. Clips are located on the back panel of the fryer for the attachment of restraints.

Page 8 of the Frymaster YSCF14G user manual — YSCF14G SERIES GAS FRYERS
Page 8 · click to enlarge
Page 8

YSCF14G SERIES GAS FRYERS

CHAPTER 1: INSTALLATION

1.1 Gas Connections (cont.)

3. If disconnection of the restraint is necessary, this restraint must be reconnected after the fryer has been returned to its originally installed position. J. After hook-up, bleed the gas line of air to ensure that the pilot light will ignite quickly.
K. CE StandardsIf the unit is to be installed with flexible coupling, use a commercial flexible

coupling certified as NF D 36123 (or other national standard) or a quick disconnect device certified NF D 36124 (or other national standard).

1.2 Electrical Connections The fryer when installed must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70-(latest edition).

receptacle. DO NOT CUT, REMOVE, OR OTHERWISE BYPASS THE GROUNDING

PRONG ON THIS PLUG! The rating plate and wiring diagram are located inside the front door. The fryer is equipped with a 120VAC single-phase 60-hertz system (Domestic), or 230VAC single-phase 50-hertz system (International/CE). Do not cut or remove the ground prong from the power cord plug. Do not attempt to use the fryer during a power outage.

the OFF position in case of a prolonged power outage. Do not attempt to operate

this appliance during a power outage.

Page 9 of the Frymaster YSCF14G user manual — 2.1 Initial Start-up
Page 9 · click to enlarge
Page 9

YSCF14G SERIES GAS FRYERS CHAPTER 2: FRYER OPERATIONS

2.1 Initial Start-up

Frymaster YSCF14G — 2.1 Initial Start-up diagram (page 9)
Fig. 17 · 2.1 Initial Start-up

the inherent hazards of operating a hot oil frying system, particularly the aspects of

A. Cleaning: New units are wiped clean with solvents at the factory to remove any visible signs

of dirt, oil, grease, etc. remaining from the manufacturing process, then coated lightly with oil. Before any food preparation, wash thoroughly with hot, soapy water to remove any film residue and dust or debris then rinse out and wipe dry. Also wash any accessories shipped with the unit. Close the drain valve completely and remove the crumb screen covering the heating tubes. Ensure the screws holding the thermostat and high-limit control sensing bulbs into the frypot are tight.

Frymaster YSCF14G — 2.1 Initial Start-up diagram (page 9)
Fig. 18 · 2.1 Initial Start-up

a tight fit and should only be removed for cleaning.

water or cooking oil/shortening before lighting the burners. Failure to do so will

damage the frypot and may cause a fire.

Frymaster YSCF14G — 2.1 Initial Start-up diagram (page 9)
Fig. 19 · 2.1 Initial Start-up

facial and body burns.

Page 10 of the Frymaster YSCF14G user manual — YSCF14G SERIES GAS FRYERS CHAPTER 2: FRYER OPERATIONS
Page 10 · click to enlarge
Page 10

YSCF14G SERIES GAS FRYERS CHAPTER 2: FRYER OPERATIONS

2.2 Final Preparation

Always wear oil-proof, insulated gloves when working with the fryer filled with hot

oil.

Always drain hot oil into a metal container. Hot oil can melt plastic buckets and

crack glass containers.

so will damage the heating tubes and frypot, and void the warranty.

A. When using a liquid shortening (cooking oil), fill the fryer to ¼" below the top OIL LEVEL

line scribed into the back of the frypot. B. When using a solid shortening, first melt it in a suitable container, or cut it into small pieces

and pack it below the heat tubes, between the tubes and on top of the tubes, leaving no air spaces around the tubes. Do not disturb or bend the sensing bulbs. Never set a complete block of solid shortening on top of the heating tubes. To do so will damage the heating tubes and frypot, and void the warranty.

C. Press the

switch to turn fryer on. The burners will initially operate in the MELT CYCLE mode until the shortening reaches 180°F (82°C). It will then automatically switch to normal operation. D. When the frypot is filled and the shortening is melted, carefully replace the frypot crumb

screen over the heat tubes. Wear oil-proof insulated gloves to avoid the potential for burn injury when replacing crumb screen.

E. Before starting operation, program the computer to the probable working temperature and

wait for the temperature to stabilize.

Page 11 of the Frymaster YSCF14G user manual — 2.2 Final Preparation
Page 11 · click to enlarge
Page 11
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 11)
Fig. 20 · 2.2 Final Preparation

operational procedures.

Frymaster YSCF14G — 2.2 Final Preparation diagram (page 11)
Fig. 21 · 2.2 Final Preparation

the inherent hazards of operating a hot oil filtration system, particularly the aspects

of oil filtration, draining and cleaning procedures.

Frymaster YSCF14G — 2.2 Final Preparation diagram (page 11)
Fig. 22 · 2.2 Final Preparation

the oil moving through the hose lines could jolt a flexible return hose (where

applicable) out of the filter pan, spraying hot oil and causing severe burns.

Frymaster YSCF14G — 2.2 Final Preparation diagram (page 11)
Fig. 23 · 2.2 Final Preparation

can spontaneously combust if left soaking in certain shortening material.

Frymaster YSCF14G — 2.2 Final Preparation diagram (page 11)
Fig. 24 · 2.2 Final Preparation

is heavy. This assures the longest life possible for the oil and minimizes flavor

transfer.

Page 12 of the Frymaster YSCF14G user manual — 2.2 Final Preparation
Page 12 · click to enlarge
Page 12

3.1 General Frymaster YSCF14G Series gas fryers come equipped with a built-in filtration system. Photos used in the procedural illustrations may differ slightly from the filter unit that came with the frying system. The following procedures apply to all YSCF14G Series gas fryers equipped with built-in filter systems. 3.2 Filtration Preparation On initial installation and before each use, remove all loose parts from the filter, wash the filter pan and all accessories in hot, soapy water and dry thoroughly. 3.2.1 Assembling the Filter The YSCF14G Series UFF filter system uses a filter pad held in place by a hold-down ring to filter impurities and debris from the cooking oil. The filter pan is assembled with the following components (see illustration): 1. Filter pan.

2. Filter support grid.
3. Filter pad.
4. Hold-down ring.
5. Crumb screen.
6. Pan cover.

3.2.1 Assembling the Filter (cont.)

Page 13 of the Frymaster YSCF14G user manual — 2.2 Final Preparation
Page 13 · click to enlarge
Page 13

Assemble the filter as follows: 1. Place the support grid in the bottom of filter pan. 2. Center the filter pad in the filter pan with the notch toward the pick-up tube. 3. Position the hold-down ring on the filter pan with the notch toward the pick-up tube. 4. Place the crumb screen in the filter pan. Allow the crumb screen to rest on the top edges of the hold-down ring.

Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 25 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 26 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 27 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 28 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 29 · 2.2 Final Preparation

Support grid properly placed in filter pan.

5. Place filter pan cover onto the filter pan assembly. Ensure the front cover is correctly positioned over the slip fitting.
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 30 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 31 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 32 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 33 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 34 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 35 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 36 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 37 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 38 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 39 · 2.2 Final Preparation

Hold-down ring shown over filter pad.

Filter pan shown with pad, hold- down ring and crumb tray in place.

Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 40 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 13)
Fig. 41 · 2.2 Final Preparation

The filter pan is shown partially inserted under the fryer.

Page 14 of the Frymaster YSCF14G user manual — 2.2 Final Preparation
Page 14 · click to enlarge
Page 14

3.2.2 Installing the Filter Slide the filter inside the fryer cabinet. Ensure the male-female slip-fitting coupling is fully engaged. 3.3 Daily Filtration Operation

Frymaster YSCF14G — 2.2 Final Preparation diagram (page 14)
Fig. 42 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 14)
Fig. 43 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 14)
Fig. 44 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 14)
Fig. 45 · 2.2 Final Preparation
Frymaster YSCF14G — 2.2 Final Preparation diagram (page 14)
Fig. 46 · 2.2 Final Preparation

Ensure the filter pan is fully seated on the male connection (left, above) when it slides into place.

350°F (177°C). Ensure all hoses are connected properly and drain handles are in their proper position prior to operating any switches or valves. Failure to do this can

result in severe burns.

operational procedures. 3.3.1 General Overview The filter pump is turned on only after the oil is brought to operating temperature and drained into the prepared filter pan. The filter motor is then engaged and oil is drawn through filter paper and pumped back into the frypot. The frypot’s drain remains open during the filtering process. Allow the oil to cycle through the filter paper for approximately 30 minutes. At the end of 30 minutes, close the drain valve and allow the pump to fill the frypot to the top OIL LEVEL line. Leave the pump running for 10-15 seconds after bubbles appear in the frypot to ensure all oil is pumped from the drain pan and the lines.

Page 15 of the Frymaster YSCF14G user manual — 2.2 Final Preparation
Page 15 · click to enlarge
Page 15

3.3.2 Filtering Tools Assemble tools to be used for filtering. These are supplied with the filter starter kit included with the fryer/filter system:

  • Frypot/Filter Brush - used to clean frypot and filter pan sides and bottom and to dislodge sediment during filtration or shortening/oil change.
  • Clean-Out Rod (design may vary)- used to dislodge heavy debris in the drain tube (when needed).
  • Filter Pad. The following tools are not required, but are recommended to make the filtering task easier.
  • Stainless Steel Crumb Scoop – for removing large debris from shortening/oil prior to filtering.

avoid the possibility of a serious burn caused by careless handling. The oil to be

filtered is at or near 350°C (177°C). Ensure all hoses are connected properly and drain handles are in their proper position before operating any switches or valves.

Wear all appropriate safety equipment when draining and filtering cooking oil or

shortening.

container for disposal.

Page 16 of the Frymaster YSCF14G user manual — 3.4 Operating the Filter (cont.)
Page 16 · click to enlarge
Page 16

3.4 Operating the Filter (cont.)

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 16)
Fig. 47 · 3.4 Operating the Filter (cont.)

overflow and spillage of hot oil/shortening.

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 16)
Fig. 48 · 3.4 Operating the Filter (cont.)

above the maximum fill line located on the container.

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 16)
Fig. 49 · 3.4 Operating the Filter (cont.)

Doing so will result in a flash fire if the oil or shortening splashes onto the burner.

Also, applying burner heat to an empty frypot will severely damage the frypot and

void all applicable warranties

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 16)
Fig. 50 · 3.4 Operating the Filter (cont.)

shortening will rush out creating the potential for severe burns.

DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage

to the ball inside will result in leaks and will void all applicable warranties. 3.4.1 Pan Preparation See Section 3.2.1– Assembling the Filter, and Section 3.2.2– Installing the Filter 3.4.2 Filter Operation

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 16)
Fig. 51 · 3.4 Operating the Filter (cont.)

temperature [~350°F (~177°C)]. 1. Turn the fryer off. Ensure the filter pan assembly is prepared as described in Section 3.2.1– Assembling the Filter.

Page 17 of the Frymaster YSCF14G user manual — 3.4 Operating the Filter (cont.)
Page 17 · click to enlarge
Page 17
2. Remove fry baskets from frypot. Prior to filtering, skim any large debris from the shortening/oil. Use extreme caution, as shortening/oil is at or near operating temperature [~350°F (~177°C)]. 3. Remove the support grid from the frypot using the clean-out rod or tongs. Stir the oil with the L-shaped Teflon brush to suspend debris prior to draining.
Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 17)
Fig. 52 · 3.4 Operating the Filter (cont.)

Prior to filtering, skim any large debris from oil in frypot.

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 17)
Fig. 53 · 3.4 Operating the Filter (cont.)

Removing support grid from frypot prior to filtering.

Page 18 of the Frymaster YSCF14G user manual — 3.4 Operating the Filter (cont.)
Page 18 · click to enlarge
Page 18

3.4.2 Filter Operation (cont.)

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 18)
Fig. 54 · 3.4 Operating the Filter (cont.)
Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 18)
Fig. 55 · 3.4 Operating the Filter (cont.)
Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 18)
Fig. 56 · 3.4 Operating the Filter (cont.)

Twist a red- handled filter lever left to right to start the filter pump.

Push a blue-handled drain lever left to right to drain a frypot. Drain only one frypot at a time.

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 18)
Fig. 57 · 3.4 Operating the Filter (cont.)
Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 18)
Fig. 58 · 3.4 Operating the Filter (cont.)
4. After ensuring the filter pan is correctly positioned under the drain tube and the pan are properly connected, drain the frypot into the filter pan. Drain only one frypot at a time. 5. After all oil has drained from the frypot into the filter pan, twist the red handle to open the oil return line and activate the filter pump.
Page 19 of the Frymaster YSCF14G user manual — 3.4 Operating the Filter (cont.)
Page 19 · click to enlarge
Page 19

3.4.2 Filter Operation (cont.) 6. Oil will begin to pump from the filter pan into the frypot. If the frypot tubes, sides and bottom have sediment deposits, clean the frypot with the cleaning brush included with the fryer. Clean beneath and under the burner tubes, using care not to disturb the probes (arrow). Probe location will vary according to fryer system. 7. Allow the oil to circulate for approximately 30 minutes (process known as "polishing") to remove suspended particles. 8. After the filter cycle is complete, close the drain valve (push the blue handle fully to the left) and allow the fryer to refill.

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 19)
Fig. 59 · 3.4 Operating the Filter (cont.)

Clean all sediment and suspended particles from the burner tubes and frypot as the oil begins to circulate. Use care not to disturb the probes (arrow) on the burner tube.

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 19)
Fig. 60 · 3.4 Operating the Filter (cont.)

Polishing the oil removes suspended particles, which increases the life of the oil.

Page 20 of the Frymaster YSCF14G user manual — 3.4 Operating the Filter (cont.)
Page 20 · click to enlarge
Page 20

3.4.2 Filter Operation (cont.) 9. After all oil is pumped back into the frypot, bubbles form, indicating air in the oil return lines. Allow the oil to bubble for 10-15 seconds to ensure all oil is evacuated from the return lines. Twist the red handle to close the oil return valve and deactivate the filter pump. 10. If the oil level is low, add oil until the level is at the top OIL LEVEL line. Remember, the oil is at operating temperature. 11. Replace the frypot grid, using care not to splash hot oil. Turn the fryer on.

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 20)
Fig. 61 · 3.4 Operating the Filter (cont.)

Allow the oil to bubble for 10-15 seconds to ensure evacuation of all shortening/oil in the return lines.

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 20)
Fig. 62 · 3.4 Operating the Filter (cont.)

Add oil until the oil level is at the top OIL LEVEL line. DO NOT OVERFILL THE FRYPOT.

Replace the frypot grid, using care not to splash hot oil.

Page 21 of the Frymaster YSCF14G user manual — 3.4 Operating the Filter (cont.)
Page 21 · click to enlarge
Page 21

3.4.2 Filter Operation (cont.) 12. Do not allow crumbs to accumulate in the crumb tray. The crumb tray MUST be emptied into a fireproof container at the end of frying operations EACH day (see DANGER statement below).

Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 21)
Fig. 63 · 3.4 Operating the Filter (cont.)
Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 21)
Fig. 64 · 3.4 Operating the Filter (cont.)
Frymaster YSCF14G — 3.4 Operating the Filter (cont.) diagram (page 21)
Fig. 65 · 3.4 Operating the Filter (cont.)

Empty the filter pan crumb tray into a fire-proof container at the end of frying operations each day. DO NOT ALLOW CRUMBS TO ACCUMULATE IN TRAY.

can spontaneously combust if left soaking in certain shortening material.

a tight fit and should only be removed for cleaning.

Page 22 of the Frymaster YSCF14G user manual — SELP
Page 22 · click to enlarge
Page 22

YSCF14G SERIES GAS FRYERS CHAPTER 4: COMPUTER OPERATION

Overview

Temperature Key Press once for current temperature, twice for setpoint.

Status Indicator Displays OFF when fryer is off, dashed lines when fryer is at setpoint. Displays HI, LO and HOT when the fryer is out of temperature range.

Lane Keys Press to initiate cook cycle. SELP appears in left display; press a menu key immediately after pressing the cook key to launch a cook cycle for the chosen product. Also used to move through programming steps. Press blue key to advance, yellow key to go back.

Key Used to enter programming modes.

1 2 3 4 5 6 7 8 9 0 ON/OFF

Tatr Pies Cstk B-in B-out New Trad

Menu Keys Press a menu key immediately after pressing a lane key to launch a cook cycle for the desired product. The keys are also used to enter names of products. Each button, when repeatedly pressed, accesses multiple letters or symbols. See example below.

1 2 DEF

3 GHI JKL MNO PQR STU VWX YZ 4 5 6 7 8 9

0 * blank space + 0

ABC

OFF 1

Turn Fryer ON 1: OFF appears in satus display when controller is off. 2: Press ON/OFF button. 3:LO-- appears in status display. 4: Dashed lines appear in the status display when the fryer is at setpoint.

--LO--

Launch Cook Cycle 1: Press a lane key. 2:SELP (Select Product) appears in the window above the pressed button. The display changes to SEL PROD in about five seconds. 3: Press the menu key for the desired product. 4: The display changes to the cooktime for the product and then alternates between remaining cooktime and the product name. 5: OUT appears at the end of the cook cycle. 6. Press Lane key to eliminate OUT display.

9:36

SELP

B-IN

OUT

Show 5 more labels / short text on this page
Checkmark · Basic Operation · --------- · B-in · B-in
Page 23 of the Frymaster YSCF14G user manual — 5.2 Daily
Page 23 · click to enlarge
Page 23

YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE

5.1 General

cooking temperature, it will cause spattering of the oil/shortening, which can result

in severe burns to nearby personnel. Any equipment works better and lasts longer when maintained properly and kept clean. Cooking equipment is no exception. The YSCF14G Series gas fryer should be kept clean during the working day and thoroughly cleaned at the end of each day. Below are recommendations for daily, weekly and periodic preventative maintenance.

5.2 Daily

contact surfaces. Read the directions and precautionary statements for use. Particular attention must be paid to the concentration of cleaner and the length of

time the cleaner remains on the food-contact surfaces.

A. Remove and wash all removable parts.

B. Clean all exterior surfaces of the cabinet. Do not use abrasive cleaners, steel wool, or any

other abrasive material on stainless steel.

C. Filter the cooking oil (See Chapter 3) and replace if necessary. The oil should be filtered

more frequently when under heavy use. 5.3 Weekly

A. Completely drain the oil from the fryer into a metal stockpot of sufficient size to safely hold

the entire contents of the frypot for disposal. Do not use a glass or plastic container.

B. Clean the frypot by following recommended store operational procedures.

Page 24 of the Frymaster YSCF14G user manual — YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE
Page 24 · click to enlarge
Page 24

YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE

5.4 Periodic/Annual This appliance should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program. Frymaster recommends that this appliance be inspected at least annually by a Factory Authorized Service Technician as follows: • Inspect the cabinet inside and out, front and rear for excessive oil build-up and/or oil migration.

  • Verify that the flue opening is not obstructed by debris or accumulations of solidified oil or shortening.
  • Verify that burners and associated components (i.e. gas valves, pilot assemblies, ignitors, etc.) are in good condition and functioning properly. Inspect all gas connections for leaks and verify that all connections are properly tightened.
  • Verify that the burner manifold pressure is in accordance with that specified on the appliance’s rating plate.
  • Verify that the temperature and high-limit probes are properly connected, tightened and functioning properly, and that mounting hardware and probe guard are present and properly installed.
  • Verify that component box components (i.e. computer/controller, transformers, relays, interface boards, etc.) are in good condition and free from oil migration build-up and other debris. Inspect the component box wiring and verify that connections are tight and that wiring is in good condition.
  • Verify that all safety features (i.e. drain safety switches, reset switches, etc.) are present and functioning properly.
  • Verify that the frypot/cookpot is in good condition and free of leaks and that the frypot/cookpot insulation is in serviceable condition. Verify that the frypot tube diffusers are present and in good condition (i.e. no visible deterioration or damage).
  • Verify that wiring harnesses and connections are tight and in good condition.
  • Built-in Filtration:
  • Inspect all oil-return and drain lines for leaks and verify that all connections are tight.
  • Inspect the filter pan for leaks and cleanliness. Empty crumbs in the crumb basket into a fireproof container. Clean basket daily. Advice owner/operator not to allow crumbs to accumulate in basket. Insist they clean the basket daily.
  • Verify that all O-rings and seals (including those on quick-disconnect fittings) are present and in good condition. Replace O-rings and seals if worn or damaged.
Page 25 of the Frymaster YSCF14G user manual — YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE
Page 25 · click to enlarge
Page 25

YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE

5.4 Periodic/Annual (cont.) Built-in Filtration (cont.): • Check filtration system integrity as follows: − With the filter pan empty, place each oil return handle, one at a time, in the ON position. Verify

that the pump activates and that bubbles appear in the cooking oil/shortening of the associated frypot. − Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify proper

functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot. − Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to

350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the ON position. Allow all cooking oil/shortening to return to the frypot (indicated by bubbles in the cooking oil/shortening). Return the oil return handle to the OFF position. The frypot should refill in no more than 2 minutes and 30 seconds. To ensure good fryer health and a safe environment, the fryer should be checked and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program. 5.5 Stainless Steel Care

burns. All stainless steel fryer cabinet parts should be wiped regularly with hot, soapy water during the day, and with a liquid cleanser designed for stainless steel at the end of each day.

A. Do not use steel wool, abrasive cloths, cleansers or powders.

B. Do not use a metal knife, spatula or any other metal tool to scrape stainless steel! Scratches

are almost impossible to remove.

C. If it is necessary to scrape the stainless steel to remove any encrusted materials, soak the area

first to soften the deposit, then use a wood or nylon scraper only.

Page 26 of the Frymaster YSCF14G user manual — YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE
Page 26 · click to enlarge
Page 26
Frymaster YSCF14G — YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE diagram (page 26)
Fig. 66
Frymaster YSCF14G — YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE diagram (page 26)
Fig. 67
Shipping Address8700 Line Avenue, Shreveport, Louisiana 71106

TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135

JULY 09 PRINTED IN THE UNITED STATES SERVICE HOTLINE

1-800-551-8633 819-6132

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Frymaster YSCF14G

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster YSCF14G

Be the first to ask — other owners or our team will answer.

Original document

Frymaster YSCF14G manual PDF

26 pages·680 KB·Fryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…