GF14 and GF40 Series Gas Fryers Installation & Operation Manual

Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.

MAR 2002 24-Hour Service Hotline 1-800-551-8633 *8195887*

Page 2 of the Frymaster GF14 user manual — CANADA
Page 2 · click to enlarge
Page 2

NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS

U.S.

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.

CANADA

This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications.

Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.

Page 3 of the Frymaster GF14 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 3 · click to enlarge
Page 3

DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all times when the fryer is in use.

DANGER This product contains chemicals known to the state of California to cause cancer and/or birth defects or other reproductive harm. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.

Page 4 of the Frymaster GF14 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 4 · click to enlarge
Page 4
Page 4 of the Frymaster GF14 user manual — NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
Page 5 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 1: GENERAL INFORMATION
Page 5 · click to enlarge
Page 5

GF14 and GF40 SERIES GAS FRYERS CHAPTER 1: GENERAL INFORMATION

1.1 Parts Ordering and Service Information

In order to assist you as quickly as possible, the Frymaster Factory Authorized Service Center (FASC) or Service Department representative requires certain information about your equipment. Most of this information is printed on a data plate affixed to the inside of the fryer door. A typical data plate is illustrated below.

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 1: GENERAL INFORMATION diagram (page 5)
Fig. 1 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 1: GENERAL I…

Parts orders must be placed directly with your local FASC or distributor. Included with fryers when shipped from the factory is a list of Frymaster FASCs. If you do not have access to this list, contact the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865-1711. When ordering parts, the following information is required:

Model Number: Serial Number: Type of Gas: Item Part Number: Quantity Needed: Service information may be obtained by contacting your local FASC. Information may also be obtained by calling the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865- 1711. When requesting service, please have the following information ready:

Model Number: Serial Number: Type of Gas: In addition to the model number, serial number, and type of gas, please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your problem.

RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.

Page 6 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 1: GENERAL INFORMATION
Page 6 · click to enlarge
Page 6

1.2 Safety Information

Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones below. CAUTION boxes contain information about actions or conditions that may cause or result in a malfunction of your system.

one container to another. 1.3 Equipment Description

The GF14 and GF40 Series gas fryers are designed for all-purpose frying. Other than the capacity of the frypot, both fryers are virtually identical. The GF14 model holds up to 40 lbs. (20 liters) of cooking oil or shortening. GF40 fryers hold up to 50 lbs. (25 liters). Both models must be manually filtered or filtered with a portable filtration unit such as the Frymaster PF50 portable filter. These fryers use a millivolt temperature control circuit, which requires no external power. Both models use an open-pot design with no tubes and have a hand-sized opening into the deep cold zone, which makes cleaning the frypot quick and easy. The fryers require installation of legs or optional casters at point of use. All fryers are shipped with a package of standard accessories. Each fryer is adjusted, tested, and inspected at the factory before crating for shipment. Frypots are constructed of welded, heavy-gauge stainless steel or cold-rolled steel. Heat is supplied by a burner assembly having multiple gas jets, which are focused on deflectors (commonly referred to as “targets”) located around the lower side of the frypot. The deflectors concentrate the heat produced by the burners on the bottom of the frypot.

Page 7 of the Frymaster GF14 user manual — QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL
Page 7 · click to enlarge
Page 7

The burner assembly can be configured for natural gas, propane, or manufactured gas, as required by the customer. A drain is tapped into the center of the frypot, with a front-controlled manual ball valve. Each fryer is equipped with a thermostat for precise temperature control. The thermostat is located near the centerline of the frypot for rapid response to changes in loads and to provide the most accurate temperature measurement. A high temperature thermostat (hi-limit) shuts off gas to the burner assembly if the controlling thermostat fails.

1.4 Installation, Operating, and Service Personnel

Operating information for Frymaster equipment has been prepared for use by qualified and/or au- thorized personnel only, as defined in Section 1.5. All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and or/authorized installation or service personnel, as defined in Section 1.5. 1.5 Definitions

QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL

Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual.

QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals, or firms, corporations, or companies which, either in person or through a representative, are engaged in and are responsible for the installation of gas- fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas precautions involved, and have complied with all requirements of applicable national and local codes. QUALIFIED SERVICE PERSONNEL Qualified service personnel are those that are familiar with Frymaster equipment and who have been authorized by Frymaster to perform service on Frymaster equipment. All authorized service personnel are required to be equipped with a complete set of service and parts manuals and stock a prescribed minimum amount of Frymaster equipment parts. A list of Frymaster Factory Authorized Service Centers (FASC) is included with the fryer when it ships from the factory. Failure to use qualified service personnel will void the Frymaster Warranty on your equipment.

Page 8 of the Frymaster GF14 user manual — QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL
Page 8 · click to enlarge
Page 8

1.6 Shipping Damage Claim Procedure Your Frymaster equipment was carefully inspected and packed before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the equipment for transport. What to do if your equipment arrives damaged:

1. File a claim for damages immediately, regardless of the extent of damages. 2. Inspect for and record all visible loss or damage, and ensure that this information is noted on the freight bill or express receipt and is signed by the person making the delivery. 3. Concealed loss or damage that was unnoticed until the equipment was unpacked should be recorded and reported to the freight company or carrier immediately upon discovery. A concealed damage claim must be submitted within 15 days of the date of delivery. Ensure that the shipping container is retained for inspection.

Frymaster DOES NOT ASSUME RESPONSIBILITY FOR DAMAGE OR LOSS

INCURRED IN TRANSIT.

Page 9 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 9 · click to enlarge
Page 9

GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS

2.1 General Installation Requirements

PROPER INSTALLATION IN ACCORDANCE WITH THE INSTRUCTIONS THAT FOLLOW IS ESSENTIAL FOR EFFICIENT, TROUBLE-FREE OPERATION OF YOUR FRYER. ANY UNAUTHORIZED ALTERATIONS MADE TO THIS EQUIPMENT WILL VOID THE FRYMASTER WARRANTY. Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Shipping Damage Claim Procedure in Chapter 1.) CLEARANCE AND VENTILATION The fryer(s) must be installed with a 6” (150 mm) clearance at both sides and back when installed adjacent to combustible construction; no clearance is required when installed adjacent to noncombustible construction. A minimum of 24” (600 mm) clearance should be provided at the front of the fryer. One of the most important considerations of efficient fryer operation is ventilation. Make sure the fryer is installed to efficiently remove combustion by-products, and the kitchen ventilation system does not produce drafts that interfere with proper burner operation. The fryer flue opening must not be placed close to the intake of the exhaust fan, and the fryer must never have its flue extended in a “chimney” fashion. An extended flue will change the combustion characteristics of the fryer, causing longer recovery time. It also frequently causes delayed ignition. To provide the airflow necessary for good combustion and burner operation, the areas surrounding the fryer front, sides, and rear must be kept clear and unobstructed. Fryers must be installed in an area with an adequate air supply and adequate ventilation. Adequate distances must be maintained from the flue outlet of the fryer to the lower edge of the ventilation filter bank. Filters should be installed at an angle of 45º. Place a drip tray beneath the lowest edge of the filter. For U.S. installation, NFPA standard No. 96 states, “A minimum distance of 18 in. (450 mm) should be maintained between the flue outlet and the lower edge of the grease filter.” Frymaster recommends that the minimum distance be 24 in. (600 mm) from the flue outlet to the bottom edge of the filter.

Hotline at 1-800-551-8633. Information on construction and installation of ventilating hoods can be found in the NFPA standard cited above. A copy of the standard may be obtained from the National Fire Protection Association, Battery March Park, Quincy, MA 02269.

Page 10 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 10 · click to enlarge
Page 10

combustible material at all times. NATIONAL CODE REQUIREMENTS The type of gas for which the fryer is equipped is marked on the data plate attached to the inside of the fryer door. Connect a fryer marked “NAT” only to natural gas, those marked “PRO” only to propane gas, and those marked “MFG” only to manufactured gas. When installing this equipment in the UNITED STATES, the installation must conform to the latest edition of the National Fuel Gas Code, ANSI Z223.1. In CANADA, installation must conform to the latest edition of Standard CAN-/GCA-B149.1 or .2, “Installation Codes for Gas Burning Appliances & Equipment”. In addition to the applicable national code or standard, installation must also be in accordance with any local codes for the area in which the equipment is installed. In AUSTRALIA, this appliance must be installed by an authorized person, in accordance with the manufacture’s instructions, local gas regulations, and requirements of AA601, “Installation Requirements for Gas Burning Appliances”. Installation shall be made with a gas connector that complies with national and local codes. In the UNITED STATES, the applicable code is ANSI Z21.69 with Addenda, “Standard for Connectors for Movable Gas Appliances”. Quick-Disconnect devices, if used, shall likewise comply with national and local codes. In the UNITED STATES, the code is ANSI Z21.41, “Standard for Quick- Disconnect Devices for Use with Gas Fuel”.

2.2 Caster/Leg Installation

Depending upon the specific configuration ordered, your fryer may have been shipped without installed casters or legs. If casters or legs are installed, you may skip this section and proceed to Section 2.3, Pre-Connection Preparations. Fryers must have casters or legs. Fryers cannot be curb mounted. Install the casters/legs in accordance with the instructions included in your accessory package. 2.3 Pre-Connection Preparations

in this section.

After the fryer has been positioned under the fry station exhaust hood, ensure the following has been accomplished: 1. Adequate means must be provided to limit the movement of fryers without depending upon the gas line connections. If a flexible gas hose is used, a restraining cable must be connected at all

Page 11 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 11 · click to enlarge
Page 11

times when the fryer is in use. The restraining cable and installation instructions are packed with the flexible hose in the accessories box that was shipped with your unit. 2. These fryers must be stabilized by installing restraining chains on fryers equipped with casters or anchor straps on fryers equipped with legs. Follow the instructions shipped with the casters/legs to properly install the chains or straps. 3. Level fryers equipped with legs by extending the adjustable portion of the leg out approximately 1 inch, and then further adjust the legs, ensuring the fryer is level and at the proper height in the exhaust hood. Frymaster recommends that the minimum distance from the flue outlet to the bottom edge of the filter be 24 in. (600 mm). For fryers equipped with casters, there are no built-in leveling devices. The floor where the fryer is to be installed must be level. 4. Refer to the data plate on the inside of the fryer door to verify that the fryer is configured for the proper type of gas before connecting the fryer quick-disconnect device or piping from the gas supply line. 5. Verify that the minimum and maximum gas supply pressures for the type of gas to be used are in accordance with the table below.

Standard for Incoming Gas Pressure GasMinimumMaximum Natural6” WC 1.49 kPa 14.94 mbar14” WC 3.49 kPa 34.87 mbar LP11” WC 2.74 kPa 27.37 mbar14” WC 3.49 kPa 34.87 mbar

2.4 Connection to Gas Line

The size of the gas line used for installation is very important. If the line is too small, the gas pressure at the burner manifold will be low. This may cause pilot outage, slow recovery and delayed ignition. The incoming gas supply line should be a minimum of 1½” (38 mm) in diameter. All single GF14/GF40 fryers using natural gas require a ¾” connection. Batteries of two and three fryers require a 1” connection. For fryers using LP gas, one pipe size smaller may be used. If in doubt about the correct pipe size, consult the local gas company. NOTE: Runs of more than 20 feet and more than 4 fittings or elbows require an increase of one pipe size, i.e., ¾” to 1” or 1” to 1¼”. Before connecting new pipe to your unit, the pipe must be thoroughly blown out to remove any foreign particles. If these foreign particles get into the burner and controls, they will cause improper and sometimes dangerous operation.

Page 12 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 12 · click to enlarge
Page 12
1. Connect the quick-disconnect hose to the fryer quick-disconnect fitting at the rear of the fryer and to the building gas line.

When using thread compound, use very small amounts on male threads only. Use a pipe thread compound that is not affected by the chemical action of LP gases (Loctite™ PST56765 Sealant is one such compound). DO NOT apply compound to the first two threads. This will ensure that the burner orifices and control valve do not become clogged. 2. Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks. A soap and water solution should be used for this purpose.

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 12)
Fig. 2 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLAT…

NOTE: The fryer must be disconnected from the gas supply piping during any pressure testing of the gas supply piping a pressures equal to or greater than ½ psig (3.45kPa or 13.84 in. W.C.). 3. Close the fryer drain valve and fill the frypot with water or boil-out solution to the bottom OIL- LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures that are described in the “Start-Up Procedure” and “Boiling Out the Frypot” topics found in Chapter 3 of this manual.

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 12)
Fig. 3 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLAT…

shortening, cooking oil, or water is in the frypot before firing your unit. 4. It is suggested that the burner manifold pressure be checked at this time by the local gas company or an authorized service agent. Refer to “Check Burner Manifold Pressure” in Section 4.3 of this manual for the proper procedure. 5. Check the thermostat calibration in accordance with the instructions in Section 4.3 of this manual. 2.5 Converting to Another Gas Type

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS diagram (page 12)
Fig. 4 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLAT…

result in fire or explosion. NEVER ATTACH YOUR FRYER TO A GAS SUPPLY FOR WHICH IT IS NOT

Page 13 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS
Page 13 · click to enlarge
Page 13

Your fryer is configured at the factory for either natural gas or Propane (LP) gas. If you desire to switch from one type of gas to another, a Factory Authorized Service Center technician must install a gas conversion kit. Call Frymaster Service (1-800-551-8633) to determine the conversion kit appropriate for your configuration and altitude. Contact your local FASC to order the kit and arrange for installation.

Page 14 of the Frymaster GF14 user manual — PILOT
Page 14 · click to enlarge
Page 14

GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS

3.1 Start-Up Procedure

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 14)
Fig. 5 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING…

The cooking oil/shortening capacity of the GF40 Series fryer is 50 lbs. (25

Before lighting the fryer, make sure the fryer is OFF and the frypot drain valve

is closed. Remove the basket support rack, if installed, and fill the frypot to

To prevent scorching, if solid shortening is being used, make sure it is tightly

packed down into the bottom of the frypot. Operating the Gas Valve: The knob on the Honeywell gas valve is placed in the PILOT or ON position by rotating it counter-clockwise. To return the knob to the OFF position, the knob must be depressed slightly to disengage its stop tab, then rotated clockwise. Lighting the Pilot and Burner:

Lighting the Pilot and Burner

PILOT

PILOT

ON

OFF

ON

OFF

Figure 1 Figure 2

Page 15 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS
Page 15 · click to enlarge
Page 15
3. Push the knob in and light the pilot. Continue to hold the knob in for about 60 seconds after the flame appears on the pilot. Release the knob. The pilot should remain lit.

CAUTION If the pilot fails to remain lit, wait five minutes before attempting to re-light. 4. With the pilot lit, push down and slowly turn the knob to the ON position (see Figure 2 on Page 3-1). 5. The burner should light and burn with a strong blue flame. Once the burner has been lit, it is controlled by the thermostat.

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 15)
Fig. 6 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING…

3.2 Boiling Out the Frypot

To ensure that the frypot is free of any contamination resulting from its manufacture, shipping, and handling during installation, the frypot must be boiled out before first use. Frymaster recommends boiling out the frypot each time the oil or shortening is changed. 1. Before lighting the burner, close the frypot drain valve and fill the frypot with a mixture of cold water and boil-out solution or detergent. Fill to the lower oil-level line. 2. Light the fryer in accordance with the lighting instructions in Section 3.1. 3. Simmer the solution for one hour.

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 15)
Fig. 7 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING…

a few minutes before resuming the process. To lessen the chance of boil

over, turn the fryer’s gas valve knob to the PILOT position occasionally. 4. After the solution has simmered for one hour, turn the gas valve knob to the PILOT position and allow the solution to cool. 5. Add one gallon (3.8 liters) of cold water and stir. Drain the solution into a suitable container and clean the frypot thoroughly.

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 15)
Fig. 8 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING…

unit. These units are not intended for this purpose, and will be damaged by

Page 16 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS
Page 16 · click to enlarge
Page 16
6. Rinse the frypot at least twice by filling the frypot with clean water and draining. Dry the frypot thoroughly with a clean, dry towel.

shortening is heated to cooking temperature.

3.3 Filling With Cooking Oil or Shortening

The GF14 Series fryer holds a minimum of 30 lbs. (15 liters) and a maximum of 40 lbs. (20 liters) of cooking oil or shortening at 70°F (21°C). The GF40 Series fryer holds a minimum of 40 lbs. (20 liters) and a maximum of 50 lbs. (25 liters) of cooking oil or shortening at 70°F (21°C). 1. Ensure the fryer’s gas valve is off or in the pilot position. 2. Close the frypot drain valve; remove the basket support rack if required. 3. Fill the frypot to the lower oil-level line. When solid shortening is used, it must be thoroughly packed down into the frypot’s cold zone. 4. To melt solid shortening without scorching, the gas valve knob should be turned to the ON position for about three seconds and then to the PILOT position for about 10 seconds repeatedly until the shortening is completely melted. If any smoke is seen during this process, the oil is heating too quickly and scorching. This melting process is not necessary with liquid shortening.

3.4 Shutting the Fryer Down

For short-term shut down during the workday, rotate the gas valve knob clockwise to the PILOT position (see Figure 1 on Page 3-1) and put the frypot covers in place (if the fryer is so equipped). When shutting the fryers down at closing time, rotate the gas valve knob to the PILOT position (see Figure 1 on Page 3-1). Depress the gas valve knob and rotate slightly clockwise. Release and continue rotating clockwise to the OFF position (see Figure 2 on Page 3-1). Put the frypot covers in place (if the fryer is so equipped).

3.5 Thermostat Operation

The thermostat on GF14/GF40 fryers is connected to a graduated knob located inside the fryer door. On GF14 models, the knob is on the left side; in GF40 models, the knob is on the right side. Rotating the knob clockwise to the desired cooking temperature (setpoint) directly adjusts the thermostat to that temperature. The thermostat controls the frypot temperature by regulating the gas supply to the burner via the gas valve.

Page 17 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS
Page 17 · click to enlarge
Page 17

The thermostat is in the full OFF position when the word OFF is at the top of the knob. A “click” will be heard when the knob is rotated from the OFF position to a temperature, or when it is rotated back to the OFF position. The thermostat may require calibration from time to time. To determine if it requires calibration, refer to Check Thermostat Calibration in Section 4.2 of this manual.

3.6 Draining and Filtering

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 17)
Fig. 9 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING…

care to avoid the possibility of a serious burn caused by careless handling.

worn when draining or filtering cooking oil or shortening. Cooking oil or shortening should be filtered at least twice daily and more often if a heavy volume of breaded product is fried. Filtering will greatly increase the life of the cooking oil or shortening and will produce a higher quality product. Frymaster recommends the use of the Frymaster PF50 Portable Filter. NOTE: When using a portable filtration unit, refer to the unit manufacturer’s operating instructions for the proper filtering procedures. The following procedure is recommended to drain and filter your cooking oil or shortening when a portable filtration unit is not available.

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 17)
Fig. 10 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING…

onto the burner. Also, applying burner heat to an empty frypot will severely

1. Rotate the gas valve knob to the PILOT or OFF position. Screw the drain extension supplied with the fryer securely into the drain valve, making sure the opening is pointing down (see illustration below).
Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS diagram (page 17)
Fig. 11 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING…

Drain Extension screwed into drain valve.

Page 18 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS
Page 18 · click to enlarge
Page 18

NOTE: If draining the fryer to dispose of the cooking oil or shortening, Frymaster recommends the use of a wheeled disposal unit equipped with a pump, such as the Frymaster SDU 50. When using a disposal unit, follow the unit manufacturer’s instructions. 2. Position a metal container with a sealable cover under the drain extension. The metal container must be capable of withstanding the hot cooking oil or shortening without leaking. Frymaster recommends that a Frymaster filter cone holder and filter cone be used when a portable filtration unit is not available. If you are using a Frymaster filter cone holder and filter cone, be sure that the cone holder rests securely on the metal container. 3. Open the drain valve slowly to avoid splattering. 4. If the drain valve becomes clogged with food particles, use a cleanout rod, available from Frymaster, to clear the valve by inserting it into the drain opening from the INSIDE of the frypot.

shortening will rush out creating the potential for severe burns.

DO NOT hammer on the drain valve with the rod or other objects. Damage to

the ball inside will result in leaks and will void the Frymaster warranty. 5. The drained shortening should be allowed to cool to 100°F (38°C) or lower before transporting the container and removing the drain extension. Cooking oil or shortening at a temperature of 140°F (60°C) or higher will result in severe burns if it comes in contact with your skin. 6. After draining the cooking oil or shortening, clean all food particles and residual oil/shortening from the frypot before refilling. Be careful! The residual oil/shortening remains hot enough to cause severe burns if it comes in contact with your skin. 7. Close the drain valve and refill the frypot with clean, filtered cooking oil or shortening to the lower oil level line.

Page 19 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND
Page 19 · click to enlarge
Page 19

GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND

OPERATOR TROUBLESHOOTING

4.1 Daily Checks and Services

Inspect Fryer and Accessories for Damage Look for loose or frayed wires, leaks, foreign material in frypot or inside cabinet, and any other indications that the fryer and accessories are not ready and safe for operation. Inspect the burner deflectors or targets to verify that each is positioned directly above its orifice, and that the flame ignites approximately 2½ inches (60mm) above the orifice. The flame should strike the center of the deflector and be a rich blue color. Call your Factory Authorized Service Center (FASC) if you see any problems. Clean Fryer Cabinet Inside and Out Clean inside the fryer cabinet with dry, clean cloth. Wipe all accessible metal surfaces and components to remove accumulations of oil or shortening and dust. Clean the outside of the fryer cabinet with a clean, damp cloth soaked with dishwashing detergent, removing oil/shortening, dust, and lint from the fryer cabinet.

cooking temperature, it can cause the oil/shortening to splatter and severely burn

nearby personnel. Filter Cooking Oil/Shortening The cooking oil/shortening used in your fryer should be filtered at least twice every day (more often if the fryer is in constant use). Refer to Section 3.6, “Draining and Filtering”, for details. 4.2 Quarterly Checks and Services

Drain and Clean Frypot During normal usage of your fryer, a deposit of carbonized cooking oil or shortening will gradually form on the inside of the frypot. This deposit must be periodically removed to maintain your fryer’s efficiency. Follow the procedures for draining the frypot in Section 3.6, the follow the “Boiling Out the Frypot” procedures in Section 3.2.

Page 20 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND
Page 20 · click to enlarge
Page 20

Clean Detachable Parts and Accessories As with the frypot, a deposit of carbonized oil/shortening will accumulate on detachable parts and accessories such as baskets and sediment trays. Wipe all detachable parts and accessories with a clean cloth dampened with a detergent solution. (Frymaster recommends the use of Frymaster Fryer ‘N’ Griddle Cleaner, available through your lo- cal distributor, for best results.) Rinse and thoroughly dry each part. Check Thermostat Calibration 1. Set the temperature control knob to 375°F (191°C), i.e., fully clockwise. 2. Let the burner cycle on and off automatically three times in order for the cooking oil/shortening temperature to become uniform. If necessary, stir to get all shortening in the bottom of the fry- pot melted. 3. Insert a good-grade thermometer or pyrometer probe into the oil/shortening, with the end near the fryer temperature-sensing probe. NOTE: The temperature-sensing probe is held by clips welded to the frypot. In GF14 fryers, the probe is on the left side of the frypot; in GF40 models, it is on the right side. 4. When the burner starts for the fourth time, the thermometer/pyrometer reading should be within the range 355-385°F (185-196°C). If it is not, calibrate as follows:

a. Remove the thermostat knob by pulling straight out on the knob with a firm, steady pull.

b. Using a small-bladed flat-tipped screwdriver inserted into the slot in the thermostat adjusting

screw, turn the adjusting screw in ¼-turn increments to adjust the temperature. Turning the screw clockwise decreases the temperature; turning it counter-clockwise increases the temperature. DO NOT allow the thermostat shaft to turn while turning the adjusting screw.

c. Recheck the thermometer/pyrometer reading the next time the burner comes on.

d. Repeat steps 4.b. through 4.c. until the thermometer/pyrometer reading remains within the

range 355-385°F (185-196°C) through several cycles. If calibration cannot be obtained for any reason, call a Factory Authorized Service Center for assistance.

e. Reinstall the thermostat knob. 5. Remove the thermometer or pyrometer. Clean Gas Valve Vent Tube

1. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease in removal.
2. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any obstruction.
3. Remove the wire and blow through the tube to ensure it is clear.
Page 21 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND
Page 21 · click to enlarge
Page 21
4. Reinstall tube and bend it so that the opening is pointing downward. 4.3 Semi-Annual Checks and Service

Check Burner Manifold Pressure

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND diagram (page 21)
Fig. 12 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIV…
Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND diagram (page 21)
Fig. 13 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIV…
3. Insert the fitting for a manometer or pressure gauge into the pressure tap hole. 4. Place the gas valve in the PILOT position and light the pilot. When the pilot lights and continues to burn, increase the setting on the thermostat knob until the burner lights. Compare the manometer or gauge reading to the appropriate table below.

GF40 Standard for Burner Manifold Pressure Gas Type Pressure

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND diagram (page 21)
Fig. 14 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIV…

GF14 Standard for Burner Manifold Pressure Gas Type Pressure

Frymaster GF14 — GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND diagram (page 21)
Fig. 15 · GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIV…
Page 22 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND
Page 22 · click to enlarge
Page 22

5. If the burner manifold pressure does not meet the specifications in the tables in Step 4, unscrew the slotted cap from the top of the gas valve regulator (adjacent to the gas valve vent tube) and turn the adjusting screw to obtain the correct pressure. Turn the screw clockwise to increase pressure, counter-clockwise to decrease pressure. 6. After adjusting the manifold pressure to the correct value, reinstall the regulator cap and turn the gas valve knob to the OFF position. 7. Remove the manometer or pressure gauge fitting from the pressure tap hole and reinstall the pipe plug. 8. Place the gas valve in the PILOT position and check for gas leaks. If no leaks are found, re-light the pilot and return the unit to operation.

4.4 Operator Troubleshooting

The tables that follow provide operators with a list of possible malfunctions, the probable causes of the malfunctions, and the corrective actions to take to correct the problem. In some cases the operator may not be able to correct the problem, but will at least be able to accurately diagnose the problem, and that will assist a qualified service technician in restoring the equipment to full operation in the shortest possible time.

Page 23 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND
Page 23 · click to enlarge
Page 23

Problem Probable Cause Corrective Action

A. Pilot is not lit. A. Light pilot.

B. Loose, dirty, or corroded terminals

B. Clean and tighten terminals on gas

on gas valve.

valve.

C. Loose, dirty, or corroded terminals

C. Clean and tighten terminals on

on thermostat.

thermostat.

D. Thermostat, gas valve, or hi-limit

D. Examine wires for signs of

wires broken or shorted.

abrasions, cuts, kinks, etc. If the wiring is obviously damaged, it will probably be necessary to replace the associated component. Call FASC.

Burner does not light at all.

E. Thermostat out of calibration. E. Check calibration of thermostat in

accordance with procedures in Section 4.2 of this manual.

F. If the above causes have all been

F. Call FASC.

ruled out, the probable causes are a failed thermostat or a failed gas valve.

A. One or more burner orifices

A. Turn gas valve knob to OFF

clogged.

position. Use thin wire to clear obstruction from burner orifices.

B. Blocked flue. B. Clear blockage from flue.

C. Fryer flue connected directly to

C. Remove chimney-like duct and

vent hood with a chimney-like duct.

allow for at least 18” (45.7cm) be- tween flue outlet and vent hood filters.

Burner does not light all the way around.

D. If the above causes have all been

D. Call FASC.

ruled out, the probable causes are a broken or missing target (GF40), a bent or missing flame deflector (GF14), or incorrect burner gas pressure.

Page 24 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND
Page 24 · click to enlarge
Page 24

Problem Probable Cause Corrective Action

A. Too little make-up air in kitchen. A. Adjust kitchen ventilation system

to increase make-up air.

B. Pilot flame directed away from

B. Reposition pilot hood to direct

first orifice of burner.

flame toward first burner orifice.

obstruction from orifices. Burner experiences delayed ignition. D. If the above causes have all been

C. One or more burner orifices

C. Use a thin wire to clear

clogged.

D. Call FASC

ruled out, the probable causes are low pilot flame (less than 1” (25mm)), low incoming gas pres- sure, or a too small incoming gas line.

A. Flue obstructed. A. Remove obstruction from flue. Flame rolling out from under fryer.

B. Too little make-up air in kitchen. B. Adjust kitchen ventilation system

to increase make-up air.

A. Clogged pilot orifice. A. Use a small wire to clear

obstruction from pilot orifice.

B. Pilot flame blowing away from

B. Eliminate draft in kitchen.

pilot generator (excessive draft in kitchen).

C. Pilot generator not inserted fully

C. Reinsert pilot generator into pilot

into pilot burner.

burner until flame surrounds tip.

Pilot repeatedly goes out.

D. Corroded connection where pilot

D. Clean pilot generator connection

generator connects to gas valve.

at gas valve.

E. If all of the above causes have

E. Call FASC.

been ruled out, the probable causes are low pilot flame, pilot generator low millivolt output, high resistance in hi-limit thermostat contacts, or a defective pilot magnet in the gas valve.

Page 25 of the Frymaster GF14 user manual — GF14 and GF40 SERIES GAS FRYERS CHAPTER 4: PREVENTIVE MAINTENANCE AND
Page 25 · click to enlarge
Page 25

Problem Probable Cause Corrective Action

A. Loose, dirty or corroded hi-limit

A. Clean/tighten hi-limit wires on gas

valve. Pilot remains lit when gas valve knob is pushed in, but goes out when released.

wires.

B. If the above does not correct the

B. Call FASC.

problem, the probable causes are a weak gas valve pilot magnet, pilot generator low millivolt output, or a high-limit thermostat stuck open.

A. Thermostat out of calibration. A. Check calibration of thermostat in

accordance with procedures in Section 4.2 of this manual. Thermostat does not control at set point.

B. Failed thermostat. B. Call FASC.

Page 26 of the Frymaster GF14 user manual — 1-800-551-8633 819-5887 MAR 2002
Page 26 · click to enlarge
Page 26
Frymaster GF14 — 1-800-551-8633 819-5887 MAR 2002 diagram (page 26)
Fig. 16

Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000

Shipping Address8700 Line Avenue, Shreveport, Louisiana 71106

TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135

Price$5.00 PRINTED IN THE UNITED STATES SERVICE HOTLINE

1-800-551-8633 819-5887 MAR 2002

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
A. Light pilot. p.23
B. Clean and tighten terminals on gas valve. p.23
C. Clean and tighten terminals on thermostat. p.23
D. Examine wires for signs of abrasions, cuts, kinks, etc. If the wiring is obviously damaged, it will probably be necessary to replace the associated component. Call FASC. p.23
E. Check calibration of thermostat in accordance with procedures in Section 4.2 of this manual. p.23
F. Call FASC. p.23
A. Turn gas valve knob to OFF position. Use thin wire to clear obstruction from burner orifices. p.23
B. Clear blockage from flue. p.23
C. Remove chimney-like duct and allow for at least 18” (45.7cm) be- tween flue outlet and vent hood filters. p.23
D. Call FASC. p.23
A. Clean/tighten hi-limit wires on gas valve. p.25
B. Call FASC. p.25
A. Check calibration of thermostat in accordance with procedures in Section 4.2 of this manual. p.25

Ask about the Frymaster GF14

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Frymaster GF14

Be the first to ask — other owners or our team will answer.

Original document

Frymaster GF14 manual PDF

26 pages·831 KB·Fryer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…