Installation Manual

Part No. 300381000 July 13, 1988 Revised: April 12, 1993
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before installing or operating this equipment


TROUBLESHOOTING 39
WATER-TO-SYRUP ‘‘RATIO’’OF DISPENSED DRINK TOO LOW OR TOO HIGH. 39 ADJUSTMENT OF DISPENSING VALVE SYRUP FLOW REGULATOR DOES NOT INCREASE TO DESIRED WATER-TO-SYRUP ‘‘RATIO” 39 ADJUSTMENT OF DISPENSING VALVE SYRUP FLOW REGULATOR DOES NOT DECREASE TO DESIRED WATER-TO-SYRUP ‘‘RATIO’’. 40 DISPENSED PRODUCT CARBONATION TOO LOW. 40 DISPENSED PRODUCT COMES OUT OF DISPENSING VALVE CLEAR BUT FOAMS IN CUP. 40 DISPENSED PRODUCT PRODUCES FOAM AS IT LEAVES DISPENSING VALVE. 40 ONLY CARBONATED WATER DISPENSED. 40 ONLY SYRUP DISPENSED. 41 WARM PRODUCT BEING DISPENSED. 41
WATER PUMP MOTOR WILL NOT OPERATE. 41 WATER PUMP MOTOR WILL NOT SHUT OFF. 41 ERRATIC CYCLING OF CARBONATOR. 42 WATER PUMP MOTOR OPERATES BUT WATER PUMP DOES NOT PUMP WATER 42 WATER PUMP CAPACITY TOO LOW. 42 COMPRESSOR DOES NOT OPERATE. 42
COMPRESSOR OPERATES CONTINUOUSLY BUT DOES NOT FORM SUFFICIENT ICE BANK. 43 CONDENSER FAN MOTOR NOT OPERATING. 44 AGITATOR MOTOR NOT OPERATING. 44 WARRANTY 45
FIGURE 1. AURORAR10,000 COOLING UNIT 1 FIGURE 2. FLOW DIAGRAM (TYPICAL INSTALLATION) 4 FIGURE 3. 240/24VAC POWER TRANSFORMER 7 FIGURE 4. COOLING UNIT SPACE REQUIRED 10 FIGURE 5. PARTS IDENTIFICATION (STANDARD COOLING UNIT W/INTERNAL CONDENSER COIL AND FAN ASSEMBLY) 22 FIGURE 6. PARTS IDENTIFICATION (COOLING UNIT REQUIRING CONNECTION TO REMOTE CONDENSER COIL AND FAN ASSEMBLY) 23 FIGURE 7. CARBONATOR LIQUID LEVEL CONTROL SWITCHES 25 FIGURE 8. WATER STRAINER SCREEN AND LIQUID DOUBLE CHECK VALVE 26 FIGURE 9. LIQUID CHECK VALVE ASSEMBLY 27 FIGURE 10. CO2 GAS CHECK VALVE 32 FIGURE 11. REFRIGERATION FLOW DIAGRAM (STANDARD COOLING UNIT W/INTERNAL CONDENSER COIL AND FAN ASS’Y) 33 FIGURE 12. REFRIGERATION FLOW DIAGRAM (COOLING UNIT REQUIRING CONNECTION TO REMOTE CONDENSER COIL AND FAN ASS’Y) 34 FIGURE 13. WIRING DIAGRAM (LOW-VOLTAGE SYSTEM) 35
Page · iii 300381000

FIGURE 14. WIRING DIAGRAM (LOW-VOLTAGE SYSTEM) 36
FIGURE 15. WIRING DIAGRAM (HIGH-VOLTAGE SYSTEM) 37
TABLE 1. DESIGN DATA 2 TABLE 2. LOOSE-SHIPPED PARTS 5
Page · iv 300381000

This section gives the description, theory of operation, and design data for the AuroraR10,000 Cooling Unit, (hereafter referred to as a ‘‘Cooling Unit’’).
The Cooling Unit is designed to provide cooled soft drink syrup, carbonated water, and plain water to dispensing station through an insulated python (length as ordered). On the standard Cooling Unit, refrigeration system is cooled by condenser coil and fan assembly located inside the Cooling Unit. Cooling Unit not provided with internal condenser coil and fan assembly is cooled by Remote Condenser Coil and Fan Assembly which is connected to Cooling Unit. The Cooling Unit consists basically of two carbonator tanks each having its own water pump to pump plain water into tanks, one carbonated water circulating pump, a Hydro Boostâ (carbonated water pre-cooler) which pre-cools carbonated water on its way to carbonated water circulating pump and a two horsepower refrigeration compressor. The cabinet panels are easily removed to facilitate installation and service and maintenance.
An optional Cooling Unit Stand (P/N 309309000) is available to elevate Cooling Unit up off floor. A System Status Display Kit (P/N 0913) is available and when installed on the Cooling Unit, allows operator or technician to monitor operation of Cooling Unit and to be aware when service is required. Also available is an Aurora Service System Analyzer (P/N 309197000) that may be used to analyze and troubleshoot the Aurora 10,000 Cooling Unit refrigeration system.

1 300381000



300381000 2

A CO2 cylinder delivers carbon dioxide gas (CO2) to primary CO2 regulator assembly which delivers regulated CO2 gas to adjustable secondary CO2 regulators. Secondary CO2 regulators deliver regulated CO2 gas to both carbonated water tanks inside Cooling Unit and also to soft drink tanks. Plain water is pumped into carbonated water tanks by water pumps and is carbonated by regulated CO2 gas pressure also entering tanks. Carbonated
water leaves carbonated water tanks and passes through the Hydro BoostR(carbonated water pre-cooler) which pre-cools carbonated water on its way to carbonated water circulating pump. Pre-cooled carbonated water enters carbonated water circulating system through inlet side of carbonated water circulating pump. Carbonated water passes from outlet side of carbonated water circulating pump, through cooling coils inside water tank, and out through insulated line to turnaround inside dispensing station. Carbonated water returns to Cooling Unit by passing through insulated line, through cooling coils, and on to carbonated water circulating pump inlet which makes up the carbonated water circulating system. As carbonated water is being dispensed from dispensing station, carbonated water circulating system is continuously being replenished from both carbonated water tanks. Regulated CO2 gas pressure, exerted upon soft drink tanks contents, forces syrup from tanks, through Cooling Unit cooling coils, and on to dispensing station through insulated lines.
Standard Cooling Unit.
The standard Cooling Unit refrigeration system is cooled by a condenser coil and fan assembly located inside Cooling Unit.
Cooling Unit Requiring Connection to Remote Condenser Coil and Fan Assembly.
The Cooling Unit refrigeration system is cooled by a Remote Condenser Coil and Fan Assembly (P/N 309602000) that is authorized by IMI Cornelius Inc. Use of any other Remote Condenser Coil and Fan Assembly must be authorized by IMI Cornelius Inc. Use of an unauthorized Remote Condenser Coil and Fan Assembly will automatically void the Cooling Unit factory warranty.
(see Figure 2) · 3 300381000

BYPASS VALVE
CARBONATOR
CARBONATED
EXTERNAL
SHUTOFF
WATER
VALVE(2)

FIGURE 2. FLOW DIAGRAM (TYPICAL INSTALLATION)
CO 2 CYLINDER SOFT DRINK TANKS
4 300381000

This section covers unpacking and inspection, selecting location, installing Cooling Unit, preparing for operation, and operation.
NOTE: The Cooling Unit was thoroughly inspected before leaving the factory and the carrier has accepted and signed for it. Any damage or irregularities should be noted at time of delivery (or not later than 15 days from date of delivery) and immediately reported to the delivering carrier. Request a written inspection report from Claims Inspector to substantiate any necessary claim. File claim with the delivering carrier, not with IMI Cornelius Inc.
Select location for Cooling Unit installation that will (1) Allow the shortest possible insulated python route from the Cooling Unit to the Dispensing Station location; (2) Allow the shortest possible refrigeration lines (not to exceed 50-ft in length) route from Remote Condenser Coil and Fan Assembly to the Cooling Unit; (3) REFER TO THE COOLING UNIT NAMEPLATE FOR THE REQUIRED POWER CIRCUIT OPERATING VOLTAGE, HZ, AND THE MINIMUM CIRCUIT AMPACITY OF THE COOLING UNIT. The power circuit for the Cooling Unit must be wired through a 40-amp minimum rated disconnect switch (not provided) and the power circuit must be
5 300381000

fused as indicated on the Unit nameplate. The power circuit may also be wired through an equivalent HACR type circuit breaker rather then the disconnect switch. THE POWER CIRCUIT MUST BE MADE UP OF COPPER CONDUCTORS AND ALL WIRING MUST CONFORM TO NATIONAL AND LOCAL ELECTRICAL CODES; (4) Close to a plain water source supply line with proper requirements; (5) Allow sufficient space around Cooling Unit (see Figure 4) for proper air circulation (18-inches on sides and back, front side open to room, and top open to ceiling); (6) Be close to permanent floor drain to route Cooling Unit water tank drain and overflow hoses to the floor drain.
1. An extreme warm climate installation may require extra caution in Remote Rooftop Condenser Coil and Fan Assembly location. Avoid hot sunny locations and seek shaded area if possible. The use of structure to shade unit from direct sun exposure and/or a platform extending unit an additional 18-inches above rooftop is highly recommended and will improve performance. Ample space must be provided on all sides and above unit for proper air circulation through unit and also access for service and maintenance. DO NOT BLOCK AIR CIRCULATION THROUGH UNIT.
NOTE: Cooling Unit outlet lines, plain water, CO2, and syrup inlet lines, Remote Condenser Coil and Fan Assembly refrigeration lines and power circuit cable (if applicable), and Cooling Unit power circuit cable each must be long enough when connected to Cooling Unit to allow pulling unit out approximately 36-inches from operating position for service and maintenance. When Cooling Unit is in operating position, excess power circuit cable, Remote Condenser Coil and Fan Assembly refrigeration lines and power circuit cable (if applicable) and plain water source and CO2 inlet lines may be coiled up behind unit.
see Figure 6 · 300381000 6

CONNECTING REMOTE CONDENSER COIL AND FAN ASS’Y (IF APPLICABLE) REFRIGERATION LINES TO COOLING UNIT
(see Figure 6 )
Connect refrigeration lines, from Remote Condenser Coil and Fan Assembly, to refrigeration connectors on back of Cooling Unit.
(see Figures 5 or 6 and 15)
IMPORTANT: Before applicable single-phase 60HZ or 50HZ electrical power circuit is connected to the Cooling Unit, service power voltage entering the building must be identified. Service power voltage entering the building will either be 208 or 230VAC and may be posted on the main service box. If not, the installer must contact the local electrical power company for information. If these two voltage identification attempts should fail, a voltage reading must be performed. If service power voltage is below 218VAC, the red electrical wire connected to the 240VAC terminal on LINE (primary) side of the 240/24VAC power transformer inside the Cooling Unit switches electrical control box (see Figure 3 and 15) must be disconnected from the 240VAC terminal and be connected to the 208VAC terminal. If voltage is above 218VAC, power transformer red electrical wire will remain connected to the 240VAC terminal. If installer is not sure of the service power voltage entering the building, leave the red electrical wire connected to the 240VAC terminal on the power transformer. If service power voltage is below 218VAC, proceed as follows:

FIGURE 3. 240/24VAC POWER TRANSFORMER

7 300381000

Connect 208/230VAC Single Phase 60Hz electrical power circuit with a 40-amp minimum rated disconnect switch (not provided) fused at 40-amps (maximum) or circuit connected through an equivalent HACR circuit breaker to electrical wires inside electrical handy box on back of cooling unit. DO NOT CONNECT ELECTRICAL POWER TO COOLING UNIT AT THIS TIME.
COOLING UNIT MUST BE PROPERLY GROUNDED, POWER CIRCUIT MUST BE MADE UP OF COPPER CONDUCTORS, AND ALL WIRING MUST CONFORM TO NATIONAL AND LOCAL ELECTRICAL CODES.
Connect 208/230VAC Single Phase 50Hz electrical power circuit with a 40-amp minimum rated disconnect switch (not provided) fused at 40-amps (maximum) or circuit connected through an equivalent HACR circuit breaker to electrical wires inside electrical handy box on back of cooling unit. DO NOT CONNECT ELECTRICAL POWER TO COOLING UNIT AT THIS TIME.
COOLING UNIT MUST BE PROPERLY GROUNDED, POWER CIRCUIT MUST BE MADE UP OF COPPER CONDUCTORS, AND WIRING MUST CONFORM TO APPLICABLE ELECTRICAL CODES.
CONNECTING ELECTRICAL POWER CIRCUIT TO REMOTE CONDENSER COIL AND FAN ASS’Y (IF APPLICABLE) see Figures 6 and 15)
Remote Condenser Coil and Fan Assembly (P/N 309602000)
NOTE: Electrical power circuit may be connected to the Remote Condenser Coil and Fan Assembly (P/N 309602000) in two ways. The preferred way is to draw electrical power from the Cooling Unit contactor which allows the Remote Condenser Coil and Fan assembly to operate only when the Cooling Unit refrigeration system is operating. The optional way is to connect a separate electrical power circuit (independent of the cooling unit) through an appropriately rated and fused disconnect switch or an equivalent HACR circuit breaker which allows the Remote Condenser Coil and Fan Assembly to operate at all times (independent of Cooling Unit operation).
Connect and route electrical power circuit cable from Remote Condenser Coil and Fan Assembly through fuse box (not provided), fused at 15-amps (maximum) down to Cooling Unit location. REMOTE CONDENSER COIL AND FAN ASSEMBLY MUST BE PROPERLY GROUNDED, POWER CIRCUIT MUST BE MADE UP OF COPPER CONDUCTORS, AND ALL WIRING MUST CONFORM TO NATIONAL AND LOCAL ELECTRICAL CODES.
A. Remove four screws securing electrical control box to Cooling Unit back panel, (see Figure 6) then pull control box out for access to contactor inside box.
B. Route Remote Condenser Coil and Fan Assembly power cable electrical wires through electrical handy box on back of Cooling Unit to inside of electrical control box.
C. Connect Remote Condenser Coil and Fan Assembly power cable electrical wires to T1 and T2 terminals on contactor inside Cooling Unit electrical control box.
50HZ Cooling Unit · 300381000 8

D. Reinstall Cooling Unit electrical control box and secure with four screws.
E. Install cover on electrical handy box on back of Cooling Unit.
CAUTION: Plain water inlet supply line to Cooling Unit must be 1/2-inch I.D. minimum. Check water flow rate of water inlet supply line. MINIMUM FLOW RATE MUST BE AT LEAST 250-GALLONS PER HOUR. If flow rate is less than 250-gallons per hour, ‘‘starving’’of carbonator water pump will occur. Starving will allow water pump to overheat causing safety thermostat on pump outlet to disrupt electrical power to and stop water pump motor. Carbonated water circulating pump overheating could occur if water inlet supply line flow rate drops below 250-gallons per hour. INCOMING PLAIN WATER INLET SUPPLY LINE WATER PRESSURE MUST REMAIN A MINIMUM OF 10-PSI BELOW THE CARBONATOR CO2 OPERATING PRESSURE (Example: operating CO2 pressure is 90-psi and maximum water pressure can be no more than 80-psi, etc.)
WARNING: CO2 displaces oxygen. Strict attention must be observed in the prevention of CO2 (carbon dioxide) gas leaks in the entire CO2 and soft drink system. If a CO2 gas leak is suspected, particularly in a small area, immediately ventilate the contaminated area before attempting to repair the leak. Personnel exposed to high concentration of CO2 gas will experience tremors which are followed rapidly by loss of consciousness and suffocation.
Connect flexible CO2 inlet supply line to Cooling Unit 1/4-in. flare (7/16-20) bulkhead fitting of back of unit labeled ‘‘CO2 INLET’’. DO NOT TURN ON CO2 SUPPLY TO COOLING UNIT AT THIS TIME.
(see Figure 2 )
Connect syrup source lines, from No. 1 through No. 6 soft drink tanks location, to Cooling Unit syrup inlet lines labeled No. 1 through No. 6. DO NOT CONNECT SOFT DRINK TANKS INTO SYRUP SYSTEMS AT THIS TIME.
(see Figure 2) · (see Figure 2) · 9 300381000

Connect Cooling Unit syrup outlet lines labeled No. 1 through No. 6, with barbed fittings on their ends, to insulated python lines labeled No. 1 through No. 6. Secure connections with TUBING CLAMPS (item 2).
CONNECTING COOLING UNIT PLAIN WATER OUTLET LINE TO INSULATED PYTHON PLAIN WATER LINE
Connect Cooling Unit plain water outlet line, with barbed fitting on its end, to insulated python plain water line. Secure connection with TUBING CLAMP (item 2).
CONNECTING COOLING UNIT CARBONATED WATER OUTLET LINES TO INSULATED PYTHON CARBONATED WATER LINES
Connect Cooling Unit carbonated water outlet lines, with barbed connectors on their ends, to insulated python carbonated water lines. secure Connections with TUBING CLAMPS (item 1).
18-IN.
18-IN. 18-IN.
FIGURE 4. COOLING UNIT SPACE REQUIRED

11 300381000

Cooling Unit Connected To Remote Condenser Coil and Fan Assembly. (P/N 309602000).
Place Cooling Unit REFRIGERATION POWER switch in ‘‘ON’’(up) position. Refrigeration compressor, compressor cooling fan, agitator motor, and Remote Condenser Coil and Fan Assembly will start. Cooling Unit will begin forming an ice bank and refrigerated Hydro Boostâ coil will also be chilling water. When full ice bank has been formed, Remote Condenser oil and Fan Assembly, Cooling Unit compressor, and compressor cooling fan will stop but agitator motor will continue to operate circulating ice water bath in water tank.
Standard Cooling Unit Utilizing Condenser Coil and Fan Assembly.
Place Cooling Unit REFRIGERATION POWER switch in ‘‘ON’’(up) position. Refrigeration compressor, condenser fan motor, and agitator motor will start and begin forming an ice bank. When full ice bank has been formed, compressor and condenser fan motor will stop but, agitator motor will continue to operate circulating ice water bath in water tank.
Sugar Syrup Soft Drink Tanks CO2 Regulator.
Adjust sugar syrup soft drink tanks secondary CO2 regulator at 40-psig for syrup lines up to 10-feet in length plus one pound for each additional length of 10-feet, plus one pound for each 2-feet of vertical lift. For example: if syrup line total length is 30-feet and total vertical lift is 6-feet, then 40-psig + 2-psig (1-pound for every 10-feet of length over 10-feet which is 20-feet) + 3-psig (1-pound for every 2-feet of vertical lift which is 6-feet); total equals 40 + 2 + 3 = 45-psig CO2 regulator setting.
Low-Calorie (diet) Syrup Soft Drink Tank CO2 Regulator.
Adjust low-calorie (diet) soft drink tank secondary CO2 regulator for low-calorie drink at 10-psig for syrup lines up to 30-feet in length. Syrup lines longer than 30-feet in length may require a slightly higher CO2 regulator setting to 12-psig maximum. Excessive CO2 pressure may cause low-calorie syrup carbonation resulting in foam.
300381000 12

ADJUSTING WATER FLOW RATE
Refer to Installation Instructions provided with dispensing station for dispensing valve water flow rate adjustment instructions.
Adjust dispensing station dispensing valves for Water- to-Syrup ‘‘Ratio’’of dispensed product as instructed in dispensing station Installation Instructions.
Install LABEL, LINE IDENTIFICATION (item 3) on Cooling Unit and record syrup flavors in proper spaces.
13 300381000

300381000 14

This section covers operating controls, daily pre-operation check, adjustments, replenishing CO2 and syrup supplies, cleaning and sanitizing, Cooling Unit maintenance, Remote Condenser Coil and Fan Assembly (if applicable) maintenance, lubrication, and servicing CO2 gas check valves.
(see Figure 5 or 6)
REFRIGERATION POWER switch, located on front of Cooling Unit, placed in ‘‘OFF’’position will interrupt electrical power to refrigeration compressor, agitator motor, condenser fan motor (if applicable), and carbonated water circulating pump. Switch must be in ‘‘ON’’(up) position for operation. REFRIGERATION POWER SWITCH DOES NOT DISRUPT ELECTRICAL POWER TO CARBONATORS PUMPS MOTORS.
(see Figure 5 or 6)
CARBONATOR MOTORS power switch, located on front of Cooling Unit, placed in ‘‘OFF’’(down) position will interrupt electrical power to both carbonators pumps motors. Switch must be placed in ‘‘ON’’(up) position before carbonators will operate.
(see Figure 5 or 6)
CIRCULATING MOTOR power switch, located on front of Cooling Unit, placed in ‘‘OFF’’(down) position will interrupt electrical power to carbonated water circulating pump. Switch must be placed in ‘‘ON’’(up) position before circulating pump will operate.
Cooling Unit with Internal Condenser Coil and Fan Assembly.
The Cooling Unit is equipped with a refrigeration system temperature sensor which will automatically initiate shutdown if the temperature of the liquid return line from the condenser exceeds 155°F. Temperature rise may be caused by a clogged condenser coil air intake filter, or refrigeration components problem. After cool down, the refrigeration system will restart as required.
(see Figure 5) · 300381000 15

Cooling Unit Connected to Remote Condenser Coil and Fan Assembly.
This Cooling Unit is equipped with a refrigeration system temperature sensing device and a high-pressure sensing cutout switch that will shut refrigeration system down should the system overheat due to a clogged condenser coil in the Remote Condenser Coil and Fan Assembly. If refrigeration system does not automatically restart itself after system has cooled down, high-pressure sensing cutout switch reset button (see Figure 6) will have to be pressed to reset switch. MAKE SURE REFRIGERATION SYSTEM PROBLEM IS CORRECTED. OPERATING REFRIGERATION SYSTEM IN THIS MANNER FOR PROLONGED PERIOD OF TIME COULD RESULT IN COMPRESSOR FAILURE.
CO2 regulators should be periodically checked for proper pressure settings and if necessary, adjusted as instructed.
If adjustment of dispensing valves water flow rate should be necessary, adjust as instructed in dispensing station Installation Instructions.
Water-To-Syrup ‘‘Ratio’’of dispensed product should be checked and if necessary, adjusted as instructed in dispensing station Installation Instructions.
Adjust drink size of dispensed product as instructed in dispensing station Installation Instructions.
The carbonator tank liquid level (40 to 60-ounces) pump cut-in and cut-out were adjusted at the factory and should require no further adjustment. If incorrect adjustment is suspected, adjust as instructed.
WARNING: CO2 displaces oxygen. Strict attention must be observed in the prevention of CO2 (carbon dioxide) gas leaks in the entire CO2 and soft drink system. If a CO2 gas leak is suspected, particularly in a small area, immediately ventilate the contaminated area before attempting to repair the leak. Personnel exposed to high concentration of CO2 gas will experience tremors which are followed rapidly by loss of consciousness and suffocation.
(see Figure 6) · 300381000 16

Syrup supply should be checked daily and if necessary, replenished as instructed.
Perform daily cleaning of dispensing station as instructed in dispensing station Installation Instructions. Outside of Cooling Unit must be cleaned periodically.
Syrup systems should be sanitized every 90 days as instructed following Sanitizer Manufacturer’s recommendations.
CAUTION: Cooling Unit equipped with condenser coil is equipped with an air filter that must be cleaned every 30 days as instructed. Circulating air, required to cool the coil, is drawn in through air filter on back, and is exhausted out through coil on front of Unit. Failure to clean and allowing air filter to become clogged, will cause refrigeration system to overheat which will automatically shut refrigeration system down. After refrigeration system has cooled down, system will automatically restart and operate until overheated and shut down again. OPERATING COOLING UNIT IN THIS MANNER FOR PROLONGED PERIOD OF TIME COULD RESULT IN COMPRESSOR FAILURE.
Area around Cooling Unit must be kept free of obstructions at all times for proper air circulation through the Unit. Air filter must be cleaned every 30 days as instructed.
Carbonator water pump motor bearings must be oiled periodically as instructed.
Water Pump Yearly Maintenance (or After Water System Disruptions).
Carbonator water pump water strainer screen and liquid double check valve must be inspected and cleaned at least once a year under normal circumstances and after any water system disruption (plumbing work, earthquake, etc.). Inspect and clean water strainer screen and liquid double check valve as instructed.
Lubrication · 300381000 17

Carbonated water circulating pump motor bearings must be oiled periodically as instructed.
CAUTION: Remote Condenser Coil and Fan Assembly connected to this Cooling Unit is equipped with a condenser coil that must be cleaned every 30-days. Allowing condenser coil to become clogged will cause refrigeration system to overheat which will automatically shut refrigeration system down. After condenser coil has been cleaned, high-pressure cutout switch reset button on top of switches electrical control box under Cooling Unit top cover will have to be pressed to restart refrigeration system. OPERATING COOLING UNIT IN THIS MANNER FOR PROLONGED PERIOD OF TIME COULD RESULT IN COMPRESSOR FAILURE.
Area on top of and around Remote Condenser Coil and Fan Assembly must be kept free of obstructions at all times. Condenser coil must be cleaned as instructed to maintain proper cooling of coil.
(see Figure 2 )
The CO2 gas check valves must be inspected and serviced at least once a year under normal conditions and after any CO2 system servicing or disruption as instructed.
(see Figure 6) · 300381000 18

This section describes Service and Maintenance procedures to be performed on the Cooling Unit and the Remote Condenser Coil and Fan Assembly.
CAUTION: Before shipping, storing, or relocating Cooling Unit, syrup systems must be sanitized and all sanitizing solution must be purged from syrup systems. All water must be purged from plain and carbonated water systems and ice bank must be melted and all water drained from water tank. A freezing ambient environment will cause residual water remaining inside unit to freeze resulting in damage to internal components.
Cooling Unit Equipped With Condenser Coil and Air Intake Filter.( see Figure 5 )
CAUTION: Cooling Unit equipped with condenser coil is equipped with an air filter that must be cleaned every 30 days as instructed. Circulating air, required to cool the coil, is drawn in through air filter on back, and is exhausted out through coil on front of Unit. Failure to clean and allowing the air filter to become clogged, will cause refrigeration system to overheat which will automatically shut refrigeration system down. After refrigeration system has cooled down, system will automatically restart and operate until overheated and shut down again. OPERATING COOLING UNIT IN THIS MANNER FOR PROLONGED PERIOD OF TIME COULD RESULT IN COMPRESSOR FAILURE.
Clean air filter every 30 days as instructed. Area around Cooling Unit must be kept free of obstructions at all times for proper air circulation through the unit.
Cooling Unit Utilizing a Remote Condenser Coil and Fan Assembly.
CAUTION: Remote Condenser Coil and Fan assembly connected to this Cooling Unit is equipped with a condenser coil that must be cleaned every 30-days. Allowing condenser coil to become clogged will cause refrigeration system to overheat which will automatically shut refrigeration system down. After condenser coil has been cleaned, high-pressure cutout switch reset button on top of switches electrical control box under Cooling Unit top cover will have to be pressed to restart refrigeration system. OPERATING COOLING UNIT IN THIS MANNER FOR PROLONGED PERIOD OF TIME COULD RESULT IN COMPRESSOR FAILURE.
Clean Remote Condenser Coil and Fan Assembly condenser coil every 30 days, as instructed. Make sure area on top and around unit are kept free of obstructions at all times. Air must be allowed to enter and leave unit to remove heat from condenser coil. Restricting air through condenser coil will cause Cooling Unit refrigeration system to overheat.
19 300381000

Periodically wash all external surfaces of Cooling Unit, rinse with clean water, then wipe dry with a clean soft cloth. DO NOT USE ABRASIVE TYPE CLEANERS.
Cooling Unit Equipped With Condenser Coil and Air Filter.
Condenser coil air intake filter on back of Cooling Unit may either be removed and washed out with detergent solution or may be vacuumed in place on Unit.
Remote Condenser Coil and Fan Assembly (If applicable).
(see applicable Figure 5 or 6)
A gurgle heard from Cooling Unit indicates water level in water tank is low. This indicates the water tank water level float control is not operating properly and must be repaired or replaced. If a continuous trickle of water is coming out of the water tank overflow tube, this indicates the water level float control is not shutting off properly and must be repaired or replaced. Ice water bath and ice bank should be checked for cleanliness and water tank coils and the water level float control should be checked for excessive mineral deposit build-up as follows:
(see Figure 5) · see Figure 6 · 300381000 20

(see Figures 5 or 6)
WARNING: The carbonators water inlet strainer screens, double liquid check valves, and carbonated water tanks water outlet lines single check valves, must be inspected and serviced at least once a year under normal circumstances, and after any disruptions (plumbing work, earthquake, etc.) to the water supply system that might cause turbulent (erratic) flow of water through system. Water pump with no screen or defective screen in the strainer would allow foreign particles to foul the liquid double check valve. CO2 gas could then back flow into water system and create a health hazard in water system.
21 300381000


AIR FILTER RETAINING SCREW(4)
CIRCULATING PUMP MOTOR
FILTER BRACKET
CO 2 INLET
CO 2 INLET CHECK VALVE
LIQUID DOUBLE CHECK VALVE(2)
CARBONATOR WATER PUMP(2)
CONDENSER COIL
FIGURE 5. PARTS IDENTIFICATION (STANDARD COOLING UNIT W/INTERNAL CONDENSER COIL AND
300381000 22


COIL AND FAN ASS’Y
REFRIGERATION LINES
(ITEM 4 AND 5)
TOP COVER
TOP COVER RETAINING SCREW(2)
HYDRO BOOST R

CIRCULATING PUMP
CIRCULATING PUMP MOTOR
AGITATOR MOTOR
CO 2 INLET
LIQUID DOUBLE CHECK VALVE(2)
CARBONATOR WATER PUMP(2)
REFRIGERATION
LINES CONNECTORS(2)
WATER PUMP
MOTOR(2)
CARBONATOR
TANKS(2)
COMPRESSOR COOLING FAN
FIGURE 6. PARTS IDENTIFICATION (COOLING UNIT REQUIRING CONNECTION TO REMOTE
23 300381000

Servicing Carbonator Water Pump Water Strainer Screen. (see applicable Figure 5 or 6 and 8)
Servicing Carbonator Plain Water Inlet Liquid Double Check Valve and Carbonated Water Tank Carbonated Water Outlet Line Single Liquid Check Valve. (see Figures 2, 8, and 9)
300381000 24

SWITCH ADJUSTMENT
BRACKET
LEVEL CONTROL
SWITCH(2)
SWITCH ACTUATOR(2)
FIGURE 7. CARBONATOR LIQUID LEVEL CONTROL SWITCHES
25 300381000

(see applicable Figure 5 or 6)
Carbonated water circulating pump motor bearings must be oiled periodically. Refer to oiling instructions on motor. DO NOT OVER OIL.
Adjust primary CO2 regulator on CO2 cylinder to a minimum nominal setting of 120-psi or 24-psi higher than highest setting required by the secondary CO2 regulators. Loosen CO2 regulator adjusting screw locknut. Turn adjusting screw to the right (clockwise) until regulator gage registers nominal 120-psi, then tighten adjusting screw locknut.


CHECK VALVE
WHITE TAPERED GASKET
(P/N 318040000) ELBOW
SAFETY THERMOSTAT
PUMP TO MOTOR COUPLING
WATER PUMP
WATER STRAINER SCREEN
(P/N 315348000)
O-RING (P/N 315349000)
SCREEN RETAINER
FIGURE 8. WATER STRAINER SCREEN AND LIQUID DOUBLE CHECK VALVE
(see Figure 2) · 300381000 26


No.
No.
1 317963000 Housing 2 312415000 Flat Washer, Stainless Steel 3 *312418000 Ball Seat (quad ring) 4 312419000 Ball 5 312196000 Spring 6 317965000 Retainer
* Install new ball seat at each servicing.
SECONDARY CO 2 REGULATORS
Carbonator Secondary CO2 Regulator.
Adjust carbonators secondary CO2 regulator to a nominal 90-psi. Loosen CO2 regulator adjusting screw locknut. Turn adjusting screw to the right (clockwise) until regulator gage registers nominal 90-psi, then tighten adjusting screw locknut. CO2 PRESSURE TO CARBONATORS MUST NOT EXCEED 125-PSIG.
Sugar Syrup Soft Drink Tanks CO2 Regulator.
Adjust sugar syrup soft drink tanks secondary CO2 regulator at 40-psig for syrup lines up to10-feet in length plus one pound for each additional length of 10-feet, plus one pound for each 2-feet of vertical lift. For example: if syrup line total length is 30-feet and total vertical lift is 6-feet, then 40-psig+ 2-psig (1-pound for every10-feet of length over10-feet which is 20-feet)+3-psig (1-pound for every 2-feet of vertical lift which is 6-feet); total equals 40+2+3=45-psig CO2 regulator setting.
Low-Calorie (diet) Syrup Soft Drink Tank CO2 Regulator.
Adjust low-calorie (diet) soft drink tank secondary CO2 regulator for low-calorie drink at 10-psig for syrup lines up to 30-feet in length. Syrup lines longer than 30-feet in length may require a slightly higher CO2 regulator setting to 12-psig maximum. Excessive CO2 pressure may cause low-calorie syrup carbonation resulting in foam.

Refer to Installation Instructions provided with dispensing station for dispensing valve water flow rate adjustment instructions.
Adjust dispensing station dispensing valves for Water-to-Syrup ‘‘Ratio’’of dispensed product as instructed in dispensing station Installation Instructions.
Under 40-ounces of carbonated water dispensed.
If total amount of carbonated water dispensed is under 40-ounces, loosen screw securing switch adjustment bracket and move bracket up slightly. Moving bracket up allows weight of more water in tank to push tank further down before activating liquid level control switches which shuts off water pump. Tighten screw after adjustment.
Over 60-ounces of carbonated water dispensed.
If total measurement of carbonated water dispensed is over 60-ounces, loosen screw securing switch adjustment bracket and move bracket down slightly. Moving bracket down allows weight of less water in tank o activate liquid level control switches which shuts off water pump motor. Tighten screw after adjustment.
(see Figure 7) · 300381000 28

The post-mix syrup systems should be sanitized every 90-days using a non-scented household liquid bleach containing a 5.25 % sodium hypochlorite concentration. Proceed as follows to sanitize the post-mix syrup systems.
A. Observe and note CO2 pressure setting on the syrup tanks CO2 regulator, then re-adjust CO2 regulator to 60 to 80-psi. Pressurize syrup tank containing detergent solution to 60 to 80-psi.
B. Connect detergent solution tank, pressurized at 60 to 80-psi, into one of the syrup systems.
Bag-in Box Syrup Systems.
C. Install bag valves, cut from empty bag-in-box syrup containers, on ends of syrup containers syrup outlet tubes connectors.
D. Place all syrup outlet tubes, with bag valves on their ends, in container containing detergent solution.
A. Place waste container under applicable dispensing valve.
B. Activate the dispensing valve for one minute to purge all syrup and flush out the syrup system.
C. Continue to activate the dispensing valve in cycles (“ON”for 15-seconds, “OFF”, then “ON”for 15-seconds). Repeat “ON”and “OFF”cycles for 15-cycles.
Connect syrup tank containing potable water, pressurized at 60 to 80-psi, into one of the syrup systems.
Bag-in-Box Syrup System.
Fill five-gallon container with potable water, then place all bag-in-box syrup containers syrup outlet tubes in container containing potable water.
A. Place waste container under applicable dispensing valve.
B. Activate the dispensing valve for one minute to purge all detergent solution and flush out the syrup system.
29 300381000

C. Continue to activate the dispensing valve in cycles (“ON”for 15-seconds, “OFF”, then “ON”for 15-seconds). Repeat “ON”and “OFF”cycles for 15-cycles.
Connect sanitizing solution tank, pressurized at 60 to 80-psi, into one of the syrup systems.
Bag-in-Box Syrup System.
Place all bag-in-box syrup containers syrup outlet tubes in container containing sanitizing solution.
A. Place waste container under applicable dispensing valve.
B. Activate the dispensing valve for one minute to purge all water from and install sanitizing solution in the syrup system and dispensing valve.
C. Continue to activate the dispensing valve in cycles (“ON”for 15-seconds, “OFF”, then “ON”for 15-seconds). Repeat “ON”and “OFF”cycles for 15-cycles.
Connect syrup tank containing potable water, pressurized at 60 to 80-psi, into one of the syrup systems.
Bag-in-Box Syrup System.
Place all bag-in-box syrup containers syrup outlet tubes in container containing potable water.
A. Place waste container under applicable dispensing valve.
B. Activate the dispensing valve for one minute to purge all sanitizing solution out of the syrup system and the dispensing valve.
C. Continue to activate the dispensing valve in cycles (“ON”for 15-seconds, “OFF”, then “ON”for 15-seconds). Repeat “ON”and “OFF”cycles for 15-cycles.
300381000 30

A. Noting syrup tanks CO2 regulator pressure setting observed in step 4 preceding, readjust CO2 regulator to the observed pressure setting,
B. Connect tanks containing syrup into syrup systems.
Bag-in-Box Syrup System.
C. Remove all bag valves from bag-in-box syrup containers outlet tubes connectors.
D. Connect bag-in-box syrup containers into the syrup systems.
WARNING: CO2 displaces oxygen. Strict attention must be observed in the prevention of CO2 (carbon dioxide) gas leaks in the entire CO2 and soft drink system. If a CO2 gas leak is suspected, particularly in a small area, immediately ventilate the contaminated area before attempting to repair the leak. Personnel exposed to high concentration of CO2 gas will experience tremors which are followed rapidly by loss of consciousness and suffocation.
31 300381000


CLEANING CO 2 SYSTEM GAS CHECK VALVES
SECONDARY CO2 REGULATORS AND CO2 MANIFOLD CO2 GAS CHECK VALVES
(see Figures 2 and 10)
The secondary CO2 regulators and CO2 manifold CO2 gas check valves must be inspected and serviced at least once a year under normal conditions and after any servicing or disruption of the CO2 system. ALWAYS REPLACE QUAD RING SEAL EACH TIME GAS CHECK VALVES ARE SERVICED.
(see Figures 2 and 10)
Carbonators CO2 inlet lines CO2 gas check valve, located inside Cooling Unit, must be inspected and serviced at least once a year under normal conditions and after any servicing or disruption of the CO2 system. ALWAYS INSTALL NEW BALL SEAT (QUAD RING) P/N 312418000 EACH TIME CHECK VALVE IS SERVICED.
An external carbonator may be connected to the Cooling Unit (see Figure 2) for a larger supply of carbonated water.
300381000 32


FIGURE 11. REFRIGERATION FLOW DIAGRAM (STANDARD COOLING UNIT W/INTERNAL CONDENSER
33 300381000


FIGURE 12. REFRIGERATION FLOW DIAGRAM (COOLING UNIT REQUIRING CONNECTION TO
300381000 34


30-9340-001 REVISION B
FIGURE 13. WIRING DIAGRAM (LOW-VOLTAGE SYSTEM)
416593 496593 · 35 300381000


MODEL NUMBER
FIGURE 14. WIRING DIAGRAM (LOW-VOLTAGE SYSTEM)
36 300381000


MODEL NUMBERS:
FIGURE 15. WIRING DIAGRAM (HIGH-VOLTAGE SYSTEM)
416593 416594 496593 · 37 300381000

38 300381000

WARNING: If repairs are to be made to a product system, remove quick disconnects from the applicable product tank, then relieve the system pressure before proceeding. If repairs are to be made to the CO2 system, stop dispensing, shut off the CO2 supply, then relieve the system pressure before proceeding. If repairs are to be made to the refrigeration system, make sure electrical power is disconnected from the unit.
Trouble Probable Cause Remedy
WATER-TO-SYRUP ‘‘RATIO’’ OF DISPENSED DRINK TOO LOW OR TOO HIGH.
A. Dispensing valve syrup flow regulator not properly adjusted.
A. Adjust Water-To-Syrup ‘’Ratio’’ (refer to dispensing station installation Instructions).
B. CO2 gas pressure to soft drink tanks insufficient to push syrup out of tanks.
B. Adjust soft drink tanks secondary CO2 regulator as instructed.
ADJUSTMENT OF DISPENSING VALVE SYRUP FLOW REGULATOR DOES NOT INCREASE TO DESIRED WATER-TO-SYRUP ‘‘RATIO”
A. No syrup supply.
A. Replenish syrup supply as instructed.
B. Soft drink tank quick disconnects not secure.
B. Secure quick disconnects.
C. Soft drink tanks secondary CO2 regulator out of
C. Adjust soft drink tanks secondary CO2 regulator as instructed. CO2 regulator out of adjustment.
CO2 regulator as instructed.
D. Sanitize syrup system as instructed. D. Dispensing valve syrup flow regulator, soft drink tank quick disconnect, or syrup line restricted.
D. Dispensing valve syrup flow
instructed.
restricted.
E. Tapered nylon washer inside tube swivel nut connection
E. Replace nylon washer. Make sure washer seats properly in swivel tube s e ut co ect o distorted from being overtightened restricting syrup flow.
as e seats p ope y s e nut.
F. Dirty or inoperative piston or cylinder in dispensing valve syrup flow regulator.
F. Disassemble and clean dispensing valve syrup flow regulator.
39 300381000

Trouble Remedy Probable Cause
ADJUSTMENT OF DISPENSING VALVE SYRUP FLOW REGULATOR DOES NOT DECREASE TO DESIRED WATER-TO-SYRUP ‘‘RATIO’’.
A. Dirty or inoperative piston or cylinder in dispensing valve syrup flow regulator.
A. Disassemble and clean dispensing valve syrup flow regulator.
DISPENSED PRODUCT CARBONATION TOO LOW.
A. Carbonator CO2 regulator out of adjustment for existing water conditions or temperature.
A. Adjust carbonator CO2 regulator as instructed.
B. Water, oil, or dirt in CO2 supply.
B. Remove contaminated CO2 supply. Clean CO2 system (lines, regulators,etc.) using a mild detergent. Replenish with a clean CO2 supply.
DISPENSED PRODUCT COMES OUT OF DISPENSING VALVE CLEAR BUT FOAMS IN CUP.
A. Oil film or soap scum in cups. A. Use clean cups.
B. Ice used for finished drink is sub-cooled.
B. Do not use ice directly from freezer. Allow ice to become ‘‘wet’’ before using. (Refer to following NOTE)
DISPENSED PRODUCT PRODUCES FOAM AS IT LEAVES DISPENSING VALVE.
A. Carbonator CO2 regulator pressure set too high for existing water conditions or temperature.
A. Reduce carbonator CO2 regulator pressure setting as instructed.
B. Syrup over-carbonated with CO2.
B. Remove soft drink tank quick disconnects. Relieve tank CO2 pressure, shake tank vigorously, then relieve tank CO2 pressure as many times as necessary to remove over-carbonation.
C. Tapered nylon washer inside tube swivel nut connection distorted from being overtightened restricting syrup flow.
C. Replace nylon washer. Make sure washer is properly seated in swivel nut.
ONLY CARBONATED WATER DISPENSED.
A. Quick disconnect not secure on soft drink tank.
A. Secure quick disconnect on soft drink tank.
B. Out of syrup. B. Replenish syrup supply as instructed.
C. Inoperable dispensing station. C. Repair dispensing station.
D. Dispensing valve syrup flow regulator not properly adjusted.
D. Adjust dispensing valve syrup flow regulator (refer to Installation Instructions provided with dispensing station).
40 300381000

Trouble Remedy Probable Cause
E. Dispensing valve syrup flow regulator, soft drink tank quick disconnect, or syrup lines restricted.
E. Sanitize syrup system as instructed.
ONLY SYRUP DISPENSED. A. Plain water inlet supply line shutoff valve closed.
A. Open plain water inlet supply line shutoff valve.
B. CARBONATOR MOTORS power switch in ‘‘OFF’’ position.
B. Place switch in ‘‘ON’’position.
C. Water filter clogged. C. Replace water filter.
D. Frozen Hydro BoostÒ Coil. D. Allow Hydro BoostÒ Coil to thaw, then check for refrigeration problem.
WARM PRODUCT BEING DISPENSED.
A. Carbonated water circulating pump CIRCULATING MOTOR power switch in ‘‘OFF’’ position.
A. Place circulating pump CIRCULATING MOTOR power switch in ‘‘ON’’position.
B. Inoperable carbonated water circulating pump or motor.
B. Replace pump or motor.
Trouble Probable Cause Remedy
WATER PUMP MOTOR WILL NOT OPERATE.
A. Inoperative water pump motor. A. Replace water pump motor.
B. Dirty balance mechanism. B. Clean balance mechanism.
C. Loose connections and/or open electrical circuit.
C. Tighten connections and/or repair open circuit.
D. Overheated motor cut off by thermal overload protector.
D. Check for proper line voltage. Check for restricted pump discharge.
E. Inoperative level control switches.
E. Replace level control switches.
F. Binding or damaged balance mechanism.
F. Repair or replace balance mechanism.
G. Water pump binding (new or replacement pumps only).
G. Remove water pump from motor, rotate pump or motor shaft 180 degrees, then recouple pump to motor.
H. Water pump damaged. H. Replace water pump as instructed.
I. Safety thermostat inoperative. I. Replace safety thermostat.
WATER PUMP MOTOR WILL NOT SHUT OFF.
A. Foreign object restricting tank movement.
A. Remove foreign object.
B. Dirty balance mechanism. B. Clean balance mechanism.
C. Leak in carbonated water line. C. Tighten or replace line.
D. Inoperative level control switches.
D. Replace level control switches.
41 300381000

Trouble Remedy Probable Cause
E. Binding or damaged balance mechanism.
E. Repair or replace balance mechanism.
ERRATIC CYCLING OF CARBONATOR.
A. Balance mechanism spring obstructed or ‘‘cocked’’.
A. Remove obstruction. Make sure spring is perpendicular to spring release and is not twisted.
B. Dirty balance mechanism. B. Clean balance mechanism.
WATER PUMP MOTOR OPERATES BUT WATER PUMP DOES NOT PUMP
A. Clean or replace water strainer screen as instructed. PUMP DOES NOT PUMP WATER B. Kinked water supply line. B. Straighten water supply line.
A. Water pump inlet water strain screen dirty.
C. Restriction between water pump outlet and carbonator tank inlet.
C. Remove restriction.
D. Foreign object in water pump bypass.
D. Clean bypass. (Note: Count number of turns bypass screw makes when removing and install same number of turns.)
E. Water pump worn out. E. Replace water pump.
WATER PUMP CAPACITY TOO LOW.
A. Water pump inlet water strainer screen dirty.
A. Clean or replace water strainer screen as instructed.
B. Water supply capacity too low. B. Inlet water supply must be at a minimum of 250-gallons per hour with a maximum water pressure of 80-psi
C. Water filter clogged. C. Replace water filter cartridge as instructed.
D. Inoperative water pump. D. Replace water pump.
COMPRESSOR DOES NOT OPERATE.
A. Ice bank sufficient. A. Refrigeration not called for.
B. REFRIGERATION POWER switch in ‘‘OFF’’position.
B. Place REFRIGERATION POWER switch in ‘‘ON’’position.
C. Electrical power to Cooling Unit turned off.
C. Turn on electrical power to Cooling Unit.
D. No Cooling Unit power source. Blown fuse or tripped circuit breaker.
D. Replace fuse or reset circuit breaker.
E. Low voltage. E. Voltage must be at least 208 volts at compressor terminals when compressor is trying to start.
F. Loose, disconnected, or broken wiring.
F. Tighten connections or replace broken wiring.
G. Inoperable contactor. G. Replace contactor.
H. Inoperable control board. H. Replace control board.
42 300381000

Trouble Remedy Probable Cause
I. Hi-pressure cutout tripped (remote Cooling Unit only).
I. Reset pressure switch (see REFRIGERATION SYSTEM TEMPERATURE SENSING DEVICE AND HIGH-PRESSURE CUTOUT SWITCH in OPERATORS INSTRUCTIONS SECTION.
J. No voltage to control board. J. Check for loose or broken wiring. Check 240/24 VAC power transformer for 24 VAC output. (see NOTE below)
K. Inoperative compressor. K. Replace compressor.
L. Temperature sensor is shorted or open circuit.
L. Check for loose, broken, or disconnected wire or plug at pre-cool coil. Repair or replace wire. Confirm which temperature sensor has failed by using the Aurora Series System Analyzer (P/N 309197-000).
M. Loose or broken wire to satellite board from ice sensor probe on main control board (see low-voltage system wiring diagram).
M. Repair or replace wire.
COMPRESSOR OPERATES CONTINUOUSLY BUT DOES NOT FORM SUFFICIENT ICE BANK.
A. Cooling capacity is exceeded by overdrawing.
A. Reduce amount of drinks drawn per given time.
B. Standard Cooling Unit with condenser coil and fan assembly-- Cooling Unit located in excessively hot area or air circulation through condenser coil is restricted.
B. Relocate unit or check and if necessary, clean air filter as instructed.
C. Remote Rooftop Condenser Coil and Fan Assembly-- Air circulation through condenser coil is restricted.
C. Check and if necessary, clean condenser coil as instructed.
D. Insufficient refrigerant charge. D. Check refrigeration system with gage set and Aurora Series System Analyzer (P/N 309197000). Find and repair refrigeration leak, then replenish refrigerant charge.
43 300381000

Trouble Remedy Probable Cause
COMMPRESSOR OPERATES CONTINUOUSLS BUT DOES NOT FORM SUFFICIENT ICE BANK (CONT’D)
E. Inoperative or disconnected pulse-modulating expansion valve (see applicable REFRIGERATION FLOW DIAGRAM).
E. Check that expansion valve is operating by touch (should be able to feel valve pulse).Check for loose or disconnected wire to solenoid coil. If necessary, troubleshoot expansion valve with a gage set to see if it is opening. If expansion valve is not opening, suction pressure will be in a vacuum.
F. Inoperative control board. No output from board to solenoids.
F. Check LED’s on control board to see if they are modulating. Check for 24V output to pulse modulating expansion valve (see WIRING DIAGRAM). If control board green LED is on and yellow LED Is flashing; but no 24V output, replace board.
CONDENSER FAN MOTOR NOT OPERATING.
Standard Cooling Unit with Condenser Coil and Fan Assembly
A. Jumper cord loose or disconnected from condenser fan motor or terminals inside control box. Broken wire in cord.
A. Tighten connections or replace cord.
B. Fan blade obstructed. B. Remove obstruction.
C. Inoperative condenser fan motor.
C. Replace condenser fan motor.
Remote Condenser Coil and Fan assembly.
A. Blown power circuit fuse. A. Replace power circuit fuse.
B. Fan blade obstructed. B. Remove obstruction.
C. Inoperative condenser fan motor.
C. Replace condenser fan motor.
D. Cooling unit contactor inoperable.
D. Replace Cooling Unit contactor.
AGITATOR MOTOR NOT OPERATING.
A. Agitator motor propeller obstructed.
A. Remove obstruction.
B. Low voltage. B. Voltage must be at least 208 volts at compressor terminals when compressor is trying to start
C. Loose, disconnected, or broken wiring.
C. Tighten connections or replace broken wiring.
D. Inoperative agitator motor. D. Replace agitator motor.
44 300381000

IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship un- der normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or Wilshire prod- uct, in your country, please write, fax or telephone the IMI Cornelius office nearest you. Please provide the equipment model number, serial number and the date of purchase.
AUSTRALIA D P.O. 210, D RIVERWOOD, D NSW 2210, AUSTRALIA D (61) 2 533 3122 D FAX (61) 2 534 2166 AUSTRIA D AM LANGEN FELDE 32 D A-1222 D VIENNA, AUSTRIA D (43) 1 233 520 D FAX (43) 1-2335-2930 BELGIUM D BOSKAPELLEI 122 D B-2930 BRAASCHAAT, BELGIUM D (32) 3 664 0552 D FAX (32) 3 665 2307 BRAZIL D RUA ITAOCARA 97 D TOMAS COELHO D RIO DE JANEIRO, BRAZIL D (55) 21 591 7150 D FAX (55) 21 593 1829 ENGLAND D TYTHING ROAD ALCESTER D WARWICKSHIRE, B49 6 EU, ENGLAND D (44) 789 763 101 D FAX (44) 789 763 644 FRANCE D 71 ROUTE DE ST. DENIS D F-95170 DEUIL LA BARRE D PARIS, FRANCE D (33) 1 34 28 6200 D FAX (33) 1 34 28 6201 GERMANY D CARL LEVERKUS STRASSE 15 D D-4018 LANGENFELD, GERMANY D (49) 2173 7930 D FAX (49) 2173 77 438 GREECE D 488 MESSOGION AVENUE D AGIA PARASKEVI D 153 42 D ATHENS, GREECE D (30) 1 600 1073 D FAX (30) 1 601 2491 HONG KONG D 1104 TAIKOTSUI CENTRE D 11-15 KOK CHEUNG ST D TAIKOKTSUE, HONG KONG D (852) 789 9882 D FAX (852) 391 6222 ITALY D VIA PELLIZZARI 11 D 1-20059 D VIMARCATE, ITALY D (39) 39 608 0817 D FAX (39) 39 608 0814 NEW ZEALAND D 20 LANSFORD CRES. D P.O. BOX 19-044 AVONDALE D AUCKLAND 7, NEW ZEALAND D (64) 9 8200 357 D FAX (64) 9 8200 361 SINGAPORE D 16 TUAS STREET D SINGAPORE 2263 D (65) 862 5542 D FAX (65) 862 5604 SPAIN D POLIGONO INDUSTRAIL D RIERA DEL FONOLLAR D E-08830 SANT BOI DE LLOBREGAT D BARCELONA, SPAIN D (34) 3 640 2839 D FAX (34) 3 654 3379 USA D ONE CORNELIUS PLACE D ANOKA, MINNESOTA D (612) 421-6120 D FAX (612) 422-3255