Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.
24-Hour Service Hotline 1-800-551-8633 SEPTEMBER 2005

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
U.S.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.

DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all times when the fryer is in use.
DANGER This product contains chemicals known to the state of California to cause cancer and/or birth defects or other reproductive harm. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.




1.1 Applicability and Validity The Pro H55 Series Gas Fryer has been approved by the European Union for sale and installa- tion in the following EU countries: AT, BE, DE, DK, ES, FI, FR, GB, IE, IT, LU, NL, NO, PT and SE. This manual is applicable to and valid for all Pro H55 Series Gas Fryers sold in English- speaking countries, including those in the European Union. Where conflicts exist between in- structions and information in this manual and local or national codes of the country in which the equipment is installed, installation and operation shall comply with those codes. This appliance is only for professional use and shall be used by qualified personnel only, as defined in Section 1.7.
1.2 Parts Ordering and Service Information
In order to assist you quickly, the Frymaster Factory Authorized Service Center (FASC) or Service Department representative requires certain information about your equipment. Most of this information is printed on a data plate affixed to the inside of the fryer door. Part numbers are found in the Installation, Operation, Service, and Parts Manual. Parts orders may be placed directly with your local FASC or distributor. Included with fryers when shipped from the factory is a list of Frymaster FASCs. If you do not have access to this list, contact the Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711 or by e-mail: service@frymaster.com. When ordering parts, the following information is required:
Model Number: Serial Number: Type of Gas or Voltage: Item Part Number: Quantity Needed: Service information may be obtained by contacting your local FASC/Distributor. Service may also be obtained by calling the Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711 or by e-mail: service@frymaster.com. When requesting service, please have the following information ready:
Model Number: Serial Number: Type of Gas: In addition to the model number, serial number, and type of gas, please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your problem.
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.

1.3 Safety Information
Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones that follow.

in a malfunction of your system.

in damage to your system, and which may cause your system to malfunction.
in injury to personnel, and which may cause damage to your system and/or cause your
system to malfunction. Your fryer is equipped with automatic safety features: 1. High temperature detection shuts off gas to the burner assembly should the controlling thermostat fail. 2. An optional safety switch built into the drain valve prevents burner ignition with the drain valve even partially open.
1.4 European Community (CE) Specific Information
The European Community (CE) has established certain specific standards regarding equipment of this type. Whenever a conflict exists between CE and non-CE standards, the information or instructions concerned are identified by means of shadowed boxes similar to the one below.


1.5 Equipment Description Pro H55 Series high-efficiency gas fryers employ a unique infrared burner system that uses up to 43% less energy to cook the same volume as conventional open-burner fryers. Models in this series include PH55, FMPH55, and FPPH55 variants. PH55 models have no built-in filtration system. FPPH55 models have a built-in FootPrint Pro filtration system located under the leftmost two fryers in a battery. FMPH55 models also have a built-in FootPrint Pro filtration system under the leftmost two stations of a battery. The difference between FPPH55s and FMPH55s is that FPPH55s have no holding stations (i.e., the battery consists only of fryers) while the FMPH55s have a holding station at one of the positions in the battery. For example, an FPPH355 consists of three fryers with built-in filtration; an FMH355, by comparison, consists of two fryers and one holding station with built-in filtration. A PH355 consists of three fryers without built-in filtration. All Pro H55 Series Gas fryers are of an open-frypot design with no tubes and have a hand-sized opening into the deep cold zone, which makes cleaning the stainless frypot quick and easy. Heating is supplied by a pair of infrared burner assemblies mounted on each side of the frypot. Combustion air for the burners is supplied by a dedicated blower mounted on the front of the frypot. Pro H55 Series Gas fryers can be configured for natural gas, propane (LP), or manufactured gas, as required by the customer. Each frypot is equipped with a temperature probe for precise temperature control. All Pro H55 Series Gas fryers come standard with electronic ignition, melt cycle and boil-out mode. Control options include Computer Magic III.5 computers, solid-state (analog) controllers, digital controllers, and basket lift timers. All fryers in this series require an external source of AC electrical power. Units can be configured for voltages ranging from 100 VAC to 240 VAC. FMPH55 and FPPH55 fryers are shipped completely assembled. PH55 fryers may require installation of legs or optional casters at the point of use. All fryers are shipped with a package of standard accessories. Each fryer is adjusted, tested, and inspected at the factory before crating for shipment. 1.6 Installation, Operating, and Service Personnel
Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.7. All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel, as defined in Section 1.7. 1.7 Definitions
Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual.

QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals, firms, corporations, and/or companies which, either in person or through a representative, are engaged in and are responsible for the installation of gas- fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas precautions involved, and have complied with all requirements of applicable national and local codes. QUALIFIED SERVICE PERSONNEL Qualified service personnel are those who are familiar with Frymaster equipment and who have been authorized by Frymaster, L.L.C. to perform service on the equipment. All authorized service personnel are required to be equipped with a complete set of service and parts manuals, and to stock a minimum amount of parts for Frymaster equipment. A list of Frymaster Factory Authorized Service Centers (FASC) is included with the fryer when shipped from the factory. Failure to use qualified service personnel will void the Frymaster warranty on your equipment. 1.8 Shipping Damage Claim Procedure
Your Frymaster equipment was carefully inspected and packed before leaving the factory. The transportation company assumes full responsibility for safe delivery upon its acceptance of the equipment for transport. What to do if your equipment arrives damaged:
Frymaster DOES NOT ASSUME RESPONSIBILITY FOR DAMAGE OR LOSS
INCURRED IN TRANSIT.

2.1 General Installation Requirements Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.7 of this manual, should perform all installation and service on Frymaster equipment. Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and/or authorized installation or service personnel as defined in Section 1.7 of this manual. Failure to use qualified, licensed, and/or authorized installation or service personnel (as de- fined in Section 1.7 of this manual) to install, convert to another gas type or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel. Where conflicts exist between instructions and information in this manual and local or na- tional codes or regulations, installation and operation shall comply with the codes or regula- tions in force in the country in which the equipment is installed.


DANGER Frymaster appliances equipped with legs are for stationary installations. Appliances fitted with legs must be lifted during movement to avoid damage to the appliance and bodily injury. For movable installations, optional equipment casters must be used. Questions? Call 1-800-551-8633. CLEARANCE AND VENTILATION The fryer(s) must be installed with a 6” (150 mm) clearance at both sides and back when installed adjacent to combustible construction; no clearance is required when installed adjacent to noncombustible construction. A minimum of 24” (600 mm) clearance should be provided at the front of the fryer.


One of the most important considerations of efficient fryer operation is ventilation. Make sure the fryer is installed so that products of combustion are removed efficiently, and that the kitchen ventilation system does not produce drafts that interfere with burner operation. The fryer flue opening must not be placed close to the intake of the exhaust fan, and the fryer must never have its flue extended in a “chimney” fashion. An extended flue will change the combustion characteristics of the fryer, causing longer recovery time. It also frequently causes delayed ignition. To provide the airflow necessary for good combustion and burner operation, the areas surrounding the fryer front, sides, and rear must be kept clear and unobstructed.
Fryers must be installed in an area with an adequate air supply and adequate ventilation. Adequate distances must be maintained from the flue outlet of the fryer to the lower edge of the ventilation filter bank. Filters should be installed at an angle of 45º. Place a drip tray beneath the lowest edge of the filter. For U.S. installation, NFPA standard No. 96 states, “A minimum distance of 18 in. (450 mm) should be maintained between the flue outlet and the lower edge of the grease filter.” Frymaster recommends that the minimum distance be 24 in. (600 mm) from the flue outlet to the bottom edge of the filter when the appliance consumes more than 120,000 BTU per hour. For installations in the United States, information on construction and installation of ventilating hoods can be found in the NFPA standard cited above. A copy of the standard may be obtained from the National Fire Protection Association, Battery March Park, Quincy, MA 02269. NATIONAL CODE REQUIREMENTS The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of the fryer door. Connect a fryer stamped “NAT” only to natural gas, those stamped “PRO” only to propane gas, and those stamped “MFG” only to manufactured gas. Installation shall be made with a gas connector that complies with national and local codes, and, where applicable, CE codes. Quick-disconnect devices, if used, shall likewise comply with national, local, and, if applicable, CE codes. ELECTRICAL GROUNDING REQUIREMENTS All electrically operated appliances must be grounded in accordance with all applicable national and local codes, and, where applicable, CE codes. All units (cord connected or permanently connected) should be connected to a grounded power supply system. A wiring diagram is located on the inside of the fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages.

AUSTRALIAN REQUIREMENTS To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations. FCC COMPLIANCE The user is cautioned that any changes or modifications to Frymaster computers not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Frymaster computers have been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. While these devices are verified as Class A devices, they have been shown to meet the Class B limits. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of the equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The user may find the booklet “How to Identify and Resolve Radio-TV Interference Problems” helpful. It is prepared by the Federal Communications Commission and is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4. If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions.
2.2 Caster/Leg Installation
Depending upon the specific configuration ordered, your fryer may have been shipped without installed casters or legs. DO NOT INSTALL THIS APPLIANCE WITHOUT CASTERS OR LEGS. If the appliance requires the installation of casters or legs, install them in accordance with the instructions included in your accessory package. 2.3 Pre-Connection Preparations
After the fryer has been positioned under the exhaust hood, ensure the following has been accomplished: 1. Adequate means must be provided to limit the movement of fryers without depending upon the gas line connections. If a flexible gas hose is used, a restraining cable must be connected at all times when the fryer is in use. The restraining cable and installation instructions are packed with the flexible hose in the accessories box that was shipped with your unit.


3. Level fryers equipped with legs by screwing out the legs approximately 1 inch then adjusting them so that the fryer is level and at the proper height in the exhaust hood. Frymaster recommends that the minimum distance from the flue outlet to the bottom edge of the hood be 24 in. (600 mm) when the appliance consumes more than 120,000 BTU per hour. NOTE: There are no built-in leveling devices on fryers equipped with casters. The floor where the fryer is to be installed must be level. 4. Test the fryer electrical system:
a. Plug the fryer electrical cord(s) into a grounded electrical receptacle.
b. Place the power switch in the ON position.
c. Place the fryer power switch in the OFF position. Verify that the power and heat lights are
out, or that the display is blank. 5. Refer to the data plate on the inside of the fryer door to determine if the fryer burner is configured for the proper type of gas before connecting the fryer quick-disconnect device or piping from the gas supply line. 6. Verify the minimum and maximum gas supply pressures for the type of gas to be used in accordance with the accompanying tables.

CE Standard for Incoming Gas Pressures for Fryers Manufactured After April 1999
CE Standard for Incoming Gas Pressures for Fryers Manufactured Through April 1999
G20 20 2 x 3.40 2 x 3.40 7 mbar 7 mbar
G20 20 2 x 3.40 2 x 3.40 7 mbar 7 mbar
G25 20 or 25 2 x 3.40 2 x 3.40 10 mbar 10 mbar
G25 20 or 25 2 x 3.40 2 x 3.40 10 mbar 9 mbar
G30 28/30 or 50 2 x 2.05 2 x 2.05 17 mbar 17 mbar
G30 28/30 or 50 2 x 2.05 2 x 2.05 17 mbar 16,5 mbar
G31 37 or 50 2 x 2.05 2 x 2.05 20 mbar 20 mbar
G31 37 or 50 2 x 2.05 2 x 2.05 20,2 mbar 18,5 mbar


14" W.C. 3.48 kPa 34.84 mbar 7. For fryers equipped with a FootPrint Pro system or basket lifts, plug the electrical cord(s) into a power receptacle behind the fryer.
2.4 Connection to Gas Line
Never use matches, candles, or any other ignition source to check for leaks. If gas odors are detected, shut off the gas supply to the appliance at the main shut-off valve and immediately contact the local gas company or an authorized service agency for service.
DANGER “Dry-firing” your unit will cause damage to the frypot and can cause a fire. Always ensure that melted shortening, cooking oil, or water is in the frypot before firing the unit. The size of the gas line used for installation is very important. If the line is too small, the gas pressure at the burner manifold will be low. This may cause slow recovery and delayed ignition. The incoming gas supply line should be a minimum of 1½” (38 mm) in diameter. Refer to the chart on the following page for the minimum sizes of connection piping.


Gas Connection Pipe Sizes (Minimum incoming pipe size should be 1 1/2" (41 mm))
Gas Single Unit 2 - 3 Units 4 or more units*
Natural 3/4" (22 mm) 1" (28 mm) 1 1/4" (36 mm)
Propane 1/2" (15 mm) 3/4" (22 mm) 1" (28 mm)
Manufactured 1" (28 mm) 1 1/4" (36 mm) 1 1/2" (41 mm)
* For distances of more than 20 feet (6 m) and/or more than 4 fittings or elbows, increase the connection by one pipe size. The Pro H55 Series gas fryer has received the CE mark for the countries and gas categories indicated in the table below. NOTE: The nominal heat input (QN) is 21kW except for AT, DE, LU and category 3P/B, which is 23kW.
CE Approved Gas Categories by Country
COUNTRIES CATEGORIES GAS PRESSURE (MBAR) G20 20 AUSTRIA (AT) II2H3B/P G30, G31 50 I2E(R)B G20, G25 20, 25 BELGIUM (BE) I3+ G30, G31 28-30, 37 G20 20 DENMARK (DK) II2H3B/P G30, G31 30 G20, G25 20, 25 II2Esi3+ G30, G31 28-30, 37 G20, G25 20, 25 FRANCE (FR)
II2Esi3P G31 50 G20 20 FINLAND (FI) II2H3B/P G30, G31 30 G20, G25 20 II2ELL3B/P G30, G31 50 GERMANY (DE)
I3P G31 50 G20 20 GREECE (GR) II2H3+ G30, G31 28-30, 37 G20 20 ITALY (IT) II2H3+ G30, G31 28-30, 37 G20 20 IRELAND (IE) II2H3+ G30, G31 28-30, 37 G20 20 LUXEMBOURG (LU) II2E3B/P G30, G31 50 G25 25 II2L3P G31 50 G25 25 NETHERLANDS (NL)
II2L3B/P G30, G31 30 NORWAY (NO) I3B/P G30, G31 30 G20 20 PORTUGAL (PT) II2H3+ G30, G31 28-30, 37 G20 20 II2H3+ G30, G31 28-30, 37 G20 20 SPAIN (ES)
II2H3P G31 37, 50 G20 20 SWEDEN (SE) II2H3B/P G30, G31 30 G20 20 UNITED KINGDOM (UK) II2H3+ G30, G31 28-30, 37
CE Standard Required airflow for the combustion air supply is 2m3/h per kW.

When using thread compound, use very small amounts on male threads only. Use a pipe thread compound that is not affected by the chemical action of LP gases (Loctite™ PST56765 Sealant is one such compound). DO NOT apply compound to the first two threads. Doing so may allow some of the compound to enter the gas stream, resulting in clogging of burner orifices and/or the control valve. 2. Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks. A soap solution should be used for this purpose. 3. Close the fryer drain valve and fill the frypot with water and boil-out solution to the bottom OIL LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures that are described in the “Lighting Instructions” and “Boiling Out the Frypot” topics found in Chapter 3 of this manual.


CE Standard Burner Manifold Gas Pressures for Fryers Manufactured After April 1999
CE Standard Burner Manifold Gas Pressures for Fryers Manufactured Through April 1999
Vat Natural Gas Lacq (G20) under 20 mbar 7 7
Vat Natural Gas Lacq (G20) under 20 mbar 7 6,5
Natural Gas Groningue * (G25) under 25 mbar 10 10
Natural Gas Gronigue * (G25) under 25 mbar 10 9
Natural Gas Groningue (G25) under 20 mbar 10 10
Natural Gas Gronigue (G25) under 20 mbar 10 9
Butane (G30) at 28/30 or 50 mbar 17 17
Butane (G30) at 28/30 or 50 mbar 17 16,5
Propane (G31) under 37 or 50 mbar 20 20
Propane (G31) under 37 or 50 mbar 20,2 18,5
* Belgian G25 = 7,0 mbar (single or dual)
* Belgian G25 = 7,0 mbar (single) or 6,5 (dual)



Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as defined in Section 1.7 of this manual. Pro H55 Series gas fryers manufactured for Non-CE countries use different burners for each type gas. The burners in fryers built for Propane gas have a special gray-colored coating on the burner tiles to enable them to withstand the higher caloric value of the Propane gas. Burners designed for use in Propane units may be used in natural gas applications, but not vice versa.

Non-CE Gas Conversion Kits Natural Gas to Propane (LP) Gas Propane (LP) Gas to Natural Gas Full Vat: Part Number 826-1145 Full Vat: Part Number 826-1146 Dual Vat: Part Number 826-1147 Dual Vat: Part Number 826-1148
Units manufactured for export to CE countries are equipped with “universal” burners that may be used with either Natural (G20, G25) gas or Butane (G30) and Propane (G31) gasses.

CE Gas Conversion Kits for Units with Gas Valve 810-1715 G20 or G25 (Natural) to G30 or G31 Gas: G30 or G31 to G20 or G25 (Natural) Gas: Part Number 826-1196 Part Number 826-1197

CE GAS CONVERSION INSTRUCTIONS 1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the CE Standard Burner Manifold Gas Pressure Chart.) Do not change the orifice. 2. Between a 2nd family (G20 or G25) and a 3rd family gas (G30 Butane or G31 Propane): a. Change the orifices. b. Adjust the manifold pressure. 3. Affix the new label included with the conversion kit next to the existing rating plate stating that the gas type has been converted. Remove any references to the previously used gas from the existing rating plate. Conversion rating label PN 802-2144. 4. If the destination language changes, replace the labels. Call your local service agency or KES for a label kit. The language of reference will be on the corner of the label.


3.1 Controller Operation and Programming Pro H55 Series gas fryers can be equipped with any of the following controlling devices:
Before lighting the fryer, make sure the fryer is OFF and the frypot drain valve(s) is/are closed. Remove the basket support rack(s), if installed, and fill the frypot to the bottom OIL-LEVEL line.
If solid shortening is being used, make sure it is packed down into the bottom of the frypot.


Lighting the Fryer 1. Press the computer/controller ON/OFF switch to the OFF position.

Placing the ON/OFF switch in the OFF position also turns off the gas valve. Wait five minutes before continuing with Step 2, which will also turn on the gas valve.
After placing the ON/OFF switch in the OFF position, turn the gas valve knob to the OFF position. Wait 5 minutes, then turn the knob to the ON postion and proceed with Step 2.
2. Press the computer/controller ON/OFF switch to the ON position and set the thermostat or program the computer for normal cooking temperature. 3. If the burners fail to light, press the ON/OFF switch to the OFF position and wait 60 seconds. Repeat step 2. 4. The fryer will automatically enter the melt cycle mode if the frypot temperature is below 180ºF (82ºC). (NOTE: During the melt cycle, the burners will repeatedly fire for a few seconds, then go out for a longer period.) When the frypot temperature reaches 180ºF (82ºC), the unit will automatically switch to the heating mode. The burners will remain lit until the frypot temperature reaches the programmed cooking temperature. 5. After the burners have been lit for at least 90 seconds, observe the flames through the burner viewing ports located on each side of the combustion air blower.

housings. The optimum burn is a bright orange-red glow. If a blue flame is observed, or if there are dark spots on a burner face, adjust the air gas mixture as follows: On the side of the blower housing opposite

the motor is a plate with a locking nut. Loosen the nut enough to allow the plate to be moved, then adjust the position of the plate to open or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in position and tighten the locking nut.
3.3 Boiling Out the Frypot To ensure that the frypot is free of any contamination resulting from its manufacture, shipping, and handling during installation, the frypot must be boiled out before first use. Refer to Drain and Clean Frypot (page 5-1) for this procedure. 3.4 Shutting the Fryer Down
For short-term shut down during the workday, place the controller ON/OFF switch in the OFF position and put the frypot covers in place (if the fryer is so equipped). When shutting the fryers down at closing time, place the controller ON/OFF switch in the OFF position. Then place the gas valve in the off position. See illustration below.
Placing the ON/OFF switch in the OFF position also turns off the gas valve.
After placing the ON/OFF switch in the OFF position, turn the gas valve knob to the OFF position.
ON
OFF
OFF
Put the frypot covers in place (if the fryer is so equipped).



DANGER Draining and filtering of cooking oil must be accomplished with care to avoid the possibility of a serious burn caused by careless handling. The oil to be filtered is at or near 350°F (177°C). Ensure all hoses are connected properly and drain handles are in their proper position before operating any switches or valves. Wear all appropriate safety equipment when draining and filtering cooking oil.
DANGER When draining oil into a disposal unit or portable filter unit, do not fill above the maximum fill line located on the container. If your fryer is not equipped with a built-in filtration system, the cooking oil must be drained into another suitable container. (For safe, convenient draining and disposal of used cooking oil, Frymaster recommends using the Frymaster Shortening Disposal Unit (SDU). The SDU is available through your local distributor.) 1. Turn the fryer power switch to the OFF position. Screw the drainpipe (provided with your fryer) into the drain valve. Make sure the drainpipe is firmly screwed into the drain valve and that the opening is pointing down. 2. Position a metal container with a sealable cover under the drainpipe. The metal container must be able to withstand the heat of the cooking oil and hold hot liquids. If you intend to reuse the oil, Frymaster recommends that a Frymaster filter cone holder and filter cone be used when a filter machine is not available. If you are using a Frymaster filter cone holder, be sure that the cone holder rests securely on the metal container. 3. Open the drain valve slowly to avoid splattering. If the drain valve becomes clogged with food particles, use the Fryer’s Friend (poker-like tool) to clear the blockage.

DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty. 4. After draining the oil, clean all food particles and residual oil from the frypot. BE CAREFUL, this material may still cause severe burns if it comes in contact with bare skin. 5. Close the drain valve securely and fill the frypot with clean, filtered or fresh cooking oil or solid shortening to the bottom OIL-LEVEL line.
DANGER When using solid shortening, pack the shortening down into the bottom of the frypot. DO NOT operate the fryer with a solid block of shortening sitting in the upper portion of the frypot. This will cause damage to the frypot and may cause a flash fire. 4.2 Preparing the Built-In Filtration System for Use The FootPrint Pro filtration system allows the oil in one frypot to be safely and efficiently filtered while the other frypots in a battery remain in operation. The FootPrint Pro filtration system is available in three different configurations:

4.2.1 Preparation for Use with Filter Paper or Filter Pad 1. Pull the filter pan out from the cabinet and remove the crumb tray, hold-down ring, filter paper and filter screen. (See Figure 1) Clean all components with a solution of detergent and hot water then dry thoroughly.

The filter pan is equipped with rollers in rails, much like a kitchen drawer. The pan may be removed for cleaning or to gain access to interior components by lifting the front of the pan to disengage the front rollers, then pulling it forward until the rear rollers clear the rails. The pan cover must not be removed except for cleaning, interior access, or to allow a shortening disposal unit (SDU) to be positioned under the drain. 2. Inspect the filter pan connection fitting to ensure that both O-rings are in good condition. (See Figure 2) 3. Then in reverse order, place the metal filter screen in the center of the bottom of the pan, then lay a sheet of filter paper on top of the screen, overlapping on all sides. (See Figure 1) If using a filter pad, ensure the rough side of the pad is up and lay the pad over the screen, making sure that the pad is in between the embossed ridges of the filter pan. 4. Position the hold-down ring over the filter paper and lower the ring into the pan, allowing the paper to rest on the side of the filter pan. (See Figure 3)






The filter pan is equipped with rollers in rails, much like a kitchen drawer. The pan may be removed for cleaning or to gain access to interior components by lifting the front of the pan to disengage the front rollers, then pulling it forward until the rear rollers clear the rails. The pan cover must not be removed except for cleaning, interior access, or to allow a shortening disposal unit (SDU) to be positioned under the drain. NOTE: Refer to Section 4.4 for instructions on how to disassemble and reassemble the Magnasol filter screen assembly. 2. Inspect the fitting on the bottom of the Magnasol filter assembly to ensure that the O-ring is present and in good condition. (See Figure 6) 3. Inspect the filter pan connection fitting to ensure that both O-rings are present and in good condition. (See Figure 7)


Inspect the filter screen O-ring.

Inspect the filter connection fitting O-rings.



DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty.


Snap the optional Power Shower into position.

DANGER If the fryer includes a Power Shower, DO NOT operate the filter without the Power Shower in place. Hot oil will spray out of the fryer and cause injury. 3. After the cooking oil has drained from the frypot, pull the filter handle forward (outward) to start the pump and begin the filtering process. There may be a slight delay before the pump activates.




Filter Pump Reset Switch 6. Ensure the drain valve is fully closed. (If the drain valve is not fully closed, the fryer will not operate.) Turn the fryer ON and allow the cooking oil to reach setpoint.



4.4 Disassembly and Reassembly of the Magnasol Filter Dissassembly 1. Grasp the frame with your thumbs on the handles at the corner of the assembly and pull outward in opposite directions to separate the frame at the corner. Continue to open the frame (it will pivot at the opposite corner) until the outer screens and grid can be removed from the frame.
and grid.
1. Clean the two frame pieces, outer screens, and grid using a good quality degreaser and hot water from a spray nozzle. The groove in the seal frame pieces can be cleaned with the edge of a Scotch-Brite™ or similar cleaning pad. 2. At each scheduled boil-out, disassemble the leaf filter assembly and place in the frypot being boiled out. Follow the boil-out procedure in Section 5.1.2 of this manual. 3. Allow all filter assembly components to air dry or thoroughly dry with clean towels before reassembling. Reassembly 1. Place the two outer screens together and align their edges (see illustration on following page). 2. Insert the screens into one of the frame halves (it doesn’t matter which one). Ensure that the fitting in the bottom screen is on the opposite side of the frame from the handle. 3. Slip the grid between the screens, ensuring that the grid is centered between the edges of the screens. 4. Connect the other half of the frame at the corner opposite the handles and pivot the frame onto the free edges of the screen.
the outer screens

Steps 1 and 2 - Stack outer screens and insert edges into frame.
4.5 Draining and Disposing of Waste Oil When your cooking oil has reached the end of its usable life, drain the oil into an appropriate container for transport to the disposal container. Frymaster recommends the use of the Frymaster Shortening Disposal Unit (SDU). NOTE: If using an SDU built before January 2004 the filter pan cover must be removed to allow the unit to be positioned beneath the drain. To remove the lid, lift up on the front edge and pull it straight out of the cabinet. Refer to the documentation furnished with your disposal unit for specific operating instructions. If a shortening disposal unit is not available, allow the oil to cool to 100°F (38°C), then drain the oil into a metal stockpot or similar metal container. When draining is finished, close the fryer drain valve securely.
Handle




The oil discharge valve handle is shown in the OFF position. Push it down to discharge oil from the filter pan.

5.1 Fryer Preventive Maintenance Checks and Service
DAILY CHECKS AND SERVICE Inspect Fryer and Accessories for Damage Look for loose or frayed wires and cords, leaks, foreign material in frypot or inside cabinet, and any other indications that the fryer and accessories are not ready and safe for operation. Clean Fryer Cabinet Inside and Out Clean inside the fryer cabinet with dry, clean cloth. Wipe all accessible metal surfaces and compo- nents to remove accumulations of oil or shortening and dust. Clean the outside of the fryer cabinet with a clean, damp cloth soaked with dishwashing detergent, removing oil, dust, and lint from the fryer cabinet.
DANGER Never attempt to clean fryer during the cooking process or when the frypot is filled with hot oil. If water comes in contact with oil heated to cooking temperature, it can cause the oil to splatter and severely burn nearby personnel. WEEKLY CHECKS AND SERVICE Drain and Clean Frypot During normal usage of your fryer, a deposit of carbonized cooking oil will gradually form on the inside of the frypot. This deposit must be periodically removed to maintain your fryer’s efficiency.
1. Drain the frypot in accordance with Section 4.1 (page 4-1), but do not refill with cooking oil. 2. After draining the frypot, clean all food particles and residual oil from the frypot and filter pan (if so equipped). BE CAREFUL, this material may still cause severe burns if it comes in contact with bare skin. 3. Close the drain valve securely and fill the frypot with a solution of automatic dishwasher detergent and water (or commercially available boil-out solution) to the bottom OIL-LEVEL line.


WARNING Never leave the fryer unattended during this process. If the solution overflows, press the ON/OFF switch to the OFF position immediately. 5. After the solution has simmered for 1 hour, press the ON/OFF switch to the OFF position and allow the solution to cool. 6. Drain the solution into a suitable container (NOT the built-in filtration system filter pan or the Shortening Disposal Unit) and thoroughly wipe the frypot with a clean towel. 7. Close the drain valve and fill the frypot with clean, cold water and drain into a suitable container (NOT the built-in filtration system filter pan or the Shortening Disposal Unit). Repeat the rinse process again, and then wipe frypot with a clean, dry towel.

DANGER Ensure that the frypot is completely free of water before filling with cooking oil or shortening. When the oil or shortening is heated to cooking temperature, water in the frypot will cause splattering. Clean Filter Pan, Detachable Parts and Accessories As with the frypot, a deposit of carbonized oil will accumulate on the filter pan and detachable parts and accessories such as baskets, sediment trays, or fish plates. Wipe the filter pan and all detachable parts and accessories with a clean cloth dampened with a detergent solution (or the parts can be run through a dishwasher). Rinse and thoroughly dry each part. DO NOT use steel wool or abrasive pads to clean these parts. The scratches that result from such scrubbing make subsequent cleanings more difficult.


MONTHLY CHECKS AND SERVICE Check Calibration of Analog Controller Thermostat Control Knob (This check applies only to units equipped with Analog Controllers) 1. Insert a good-grade thermometer or pyrometer probe into the oil, with the end touching the fryer temperature-sensing probe and set the thermostat knob to frying temperature. 2. After the set temperature is reached, let the burner cycle on and off automatically three times to allow the cooking oil temperature to become uniform. If necessary, stir to get all shortening in the bottom of the frypot melted. 3. When the burner starts for the fourth time, the thermometer/pyrometer reading should be within ± 5ºF (2ºC) of the thermostat knob setting. If it is not, calibrate as follows:
a. Loosen setscrew in thermostat control knob until the knob will rotate freely on its shaft.
b. Rotate the knob until the index line on the knob is aligned with the marking that corresponds
to the thermometer or pyrometer reading.
c. Hold the knob and carefully tighten the setscrew.
d. Recheck the thermometer/pyrometer reading against the thermostat knob setting the next
time the burner lights.
e. Repeat steps 3.a. through 3.d. until the thermometer/pyrometer reading and knob setting
agree within ± 5ºF (2ºC). If calibration cannot be obtained for any reason, call a Factory Authorized Service Center for assistance. 5. Remove the thermometer or pyrometer. Check Computer Magic III.5 Set Point Accuracy (This check applies only to units equipped with Computer Magic III.5 Controllers.) 1. Insert a good-grade thermometer or pyrometer probe into the oil, with the end touching the fryer temperature-sensing probe. 2. When the computer display shows a series of four dashes “ ” with no dot between the first and second dashes (indicating that the frypot contents are within the cooking range), press the switch once to display the temperature of the cooking oil as sensed by the temperature probe. 3. Press the switch twice to display the set point. 4. Note the temperature on the thermometer or pyrometer. All three readings should be within ± 5ºF (2ºC) of each other. If not, contact a Factory Authorized Service Center for assistance.

Clean Combustion Air Blower Assembly 1. Disconnect the blower wiring harness and remove the four blower mounting nuts.
Blower assembly mounting nuts

Remove these fasteners.
Wrap the motor and wires
with plastic wrap or a
plastic bag.
Wiring connection · Blower Housing · Blower Wheel

Left Viewing Port is Behind
for clarity.)
The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the applicable table on page 2-7 and the burners display a bright orange-red glow. If a blue flame is observed, or if there are dark spots on a burner face, the air/gas mixture requires adjustment. On the side of the blower housing opposite the motor is a plate with one or two locking nuts. Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in position and tighten the locking nut(s).
TYPICAL BLOWER ASSEMBLY SOME CE BLOWER ASSEMBLIES MAY BE CONFIGURED THIS WAY
Right Viewing · shield omitted · Port

Clean Gas Valve Vent Tube



There are no periodic preventive maintenance checks and services required for your FootPrint Pro Filtration System other than daily cleaning of the filter pan with a solution of hot water and detergent. If you notice that the system is pumping slowly or not at all, verify that the filter pan screen is on the bottom of the filter pan, with the paper on top of the screen. (If the unit is equipped with a Magnasol filter screen rather than with the standard screen and paper system, verify that the O-ring on the bottom fitting of the screen in present and in good condition.) Verify that the two O-ring(s) on the fitting at the right front of the filter pan are present and in good condition.

CLEAN-OUT PLUGS
If the system is equipped with a Power Shower, drain the Power Shower completely after each use. If oil is leaking at the point where the Power Shower plugs into the frypot, verify that the O-ring and gasket on the connection fitting are present and in good condition. If you suspect blockage, unscrew the clean-out plugs at each corner of the frame. Place the frame in a pan of hot water for several minutes to melt any accumulation of solidified oil/shortening. Use a long, narrow bottlebrush with hot water and detergent to clean inside the tubes. If necessary, insert a straightened paper clip or similarly sized wire into the holes in the frame to remove any solidified shortening or other blockages. Rinse with hot water, dry thoroughly, and reinstall the plugs before using.

− Verify that filter pan cover is present and properly installed.
− With the filter pan empty, place each oil return handle, one at a time, in the ON position. Verify that the pump activates and that bubbles appear in the cooking oil/shortening (or that gurgling is heard from the Power Shower port if applicable) of the associated frypot.
− Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify
proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return microswitches. No air bubbles should be visible in any frypot (or no gurgling should be heard from the Power Shower ports if applicable).
− Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to
350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the ON position. Allow all cooking oil to return to the frypot (indicated by bubbles in the cooking oil or on units with Power Showers, cessation of oil flow from the Power Shower). Return the oil return handle to the OFF position. The frypot should have refilled in no more than 2 minutes and 30 seconds.

6.1 Introduction
This chapter provides an easy reference guide to some of the common problems that may occur during the operation of your equipment. The troubleshooting guides that follow are intended to help you correct, or at least accurately diagnose, problems with your equipment. Although the chapter covers the most common problems reported, you may encounter problems that are not covered. In such instances, the Frymaster Technical Services staff will make every effort to help you identify and resolve the problem. When troubleshooting a problem, always use a process of elimination starting with the simplest solution and working through to the most complex. Most importantly, always try to establish a clear idea of why a problem has occurred. Part of your corrective action involves taking steps to ensure that it doesn’t happen again. If a controller malfunctions because of a poor connection, check all other connections while you’re at it. If a fuse continues to blow, find out why. Always keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system. Some of the troubleshooting actions that are recommended in this chapter involve removing suspect components and substituting components that are known to be good. Whenever this in indicated, refer to Sections 6.6 for specific instructions If you are in doubt as to the proper action to take, do not hesitate to call the Frymaster Technical Service Department or your local Frymaster Factory Authorized Service Center for assistance. Before calling a servicer or the Frymaster HOTLINE (1-800-551-8633):

6.2 Troubleshooting Fryers with Computer Magic III.5, Basket Lift Timer, or Digital Controller
A. Controller not turned on. A. Press the ON/OFF switch to turn
the controller on.
B. Verify that the fryer is plugged in
B. No power to fryer.
and that the circuit breaker is not tripped.
C. If available, substitute a harness
known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC.
C. Damaged computer/controller
wiring harness.
controller.
D. If available, substitute a
computer/controller known to be working for the suspect computer/controller. If the fryer functions correctly, order replacement from FASC.
D. Failed computer/controller.
If available, substitute a harness
known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC. A. Drain valve not fully closed. A. Press the ON/OFF switch off,
Damaged computer/controller wiring harness or connector.
sounding.
close the drain valve(s) completely, then press the ON/OFF switch on.
B. Gas valve is not turned on. B. Turn the gas valve knob to the
ON position.
C. Verify that any in-line manual
with alarm sounding. Heating indicator is on, but
C. Manual gas shut off valve closed.
shut off valve is open. Verify that gas main cut off valve is open.
D. Verify that the quick-disconnect
D. Improperly connected quick-
fitting on the flexible gas line is firmly connected to the fryer.
disconnect fitting on gas line.
light.
E. Verify that combustion air blower
is running. If not, call FASC for service. If combustion air blower is functional, clean and adjust per instructions in Chapter 5 of this manual.
E. Obstructed or failed combustion
air blower.

A. If available, substitute a
computer/controller known to be working for the suspect computer/controller. If the fryer functions correctly, order replacement from FASC.
A. Failed computer/controller.
cycles on and off
normally, but burners will not light and blower is
B. If available, substitute a harness
known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC. Fryer is slow coming
not running. B. Damaged computer/controller
wiring harness.
out of melt cycle.
Dirty or obstructed combustion air blower.
Clean and adjust per instructions
a short time after coming out of
in Chapter 5 of this manual.
melt cycle.
normally, but recovery is slow
Dirty or obstructed combustion air blower.
Clean and adjust per instructions
in Chapter 5 of this manual.
when cooking.
A. Dirty or obstructed combustion air
A. Clean and adjust per instructions
in Chapter 5 of this manual. B. Dirty or obstructed gas valve vent
blower.
normally, but produces a popping sound when burners
B. Clean per instructions in Chapter
tube (non-CE fryers only).
5 of this manual.
ignite. C. Malfunctioning combustion air
C. If blower is slow to come up to
blower.
speed, contact FASC for service.
If available, substitute a
computer/controller known to be working for the suspect computer/controller. If the fryer functions correctly, order replacement from FASC.
and alarm sounds, but fryer operates normally
Failed computer/controller.
(false alarm).
If available, substitute a computer/controller known to be working for the suspect computer/controller. If the fryer functions correctly, order replacement from FASC. Heat indicator is on
mode or some buttons do not
Failed computer/controller.
actuate.
and blower is running, but burner
Blown fuse on interface board or ignition module. Replace fuse.
will not ignite.

If available, substitute a
Heat indicator off upon initial startup.
computer/controller known to be working for the suspect computer/controller. If the fryer functions correctly, order replacement from FASC. 6.3 Troubleshooting Fryers with Solid State (Analog) Controller
Failed computer/controller.
sounding.
A. Verify that the fryer is plugged in
A. No power to fryer.
and that the circuit breaker is not tripped.
B. If available, substitute a harness
known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC.
B. Damaged controller wiring
Power switch ON, no
harness.
fryer does not heat.
C. If available, substitute a controller
known to be working for the suspect controller. If the fryer functions correctly, order replacement from FASC.
C. Failed controller.
If available, substitute a harness known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC.
Power light ON, trouble light ON, heating mode light
Damaged controller wiring harness.
OFF.
A. Press the ON/OFF switch off,
close the drain valve(s) completely, then press the ON/OFF switch on.
A. Drain valve not fully closed.
B. Gas valve is not turned on. B. Turn the gas valve knob to the
ON position.
Power light ON, trouble light ON, heating mode light ON. Burners do not
C. Verify that any in-line manual
C. Manual gas shut off valve closed.
shut off valve is open. Verify that gas main cut off valve is open.
D. Verify that the quick-disconnect
D. Improperly connected quick-
fitting on the flexible gas line is firmly connected to the fryer.
ignite.
disconnect fitting on gas line.
E. Verify that combustion air blower
is running. If not, call FASC for service. If combustion air blower is functional, clean and adjust per instructions in Chapter 5 of this manual.
E. Obstructed or failed combustion
air blower.

A. If available, substitute a controller
known to be working for the suspect controller. If the fryer functions correctly, order replacement from FASC.
A. Failed controller.
cycles on and off normally. Blower
B. If available, substitute a harness
known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC. Fryer is slow coming
ignite. B. Damaged controller wiring
harness.
out of melt cycle. Heating mode light is ON. Trouble light
Dirty or obstructed combustion air blower.
Clean and adjust per instructions
in Chapter 5 of this manual.
comes on a short time after coming
out of melt cycle.
normally, but recovery is slow
Dirty or obstructed combustion air blower.
Clean and adjust per instructions in Chapter 5 of this manual.
when cooking.
A. Obstructed combustion air
A. Clean and adjust per instructions
in Chapter 5 of this manual. B. Dirty or obstructed gas valve vent
blower.
normally, but produces popping sound when burners
B. Clean per instructions in Chapter
tube (non-CE fryers only).
5 of this manual.
ignite. C. Malfunctioning combustion air
C. If blower is slow to come up to
speed, contact FASC for service. Heating mode light
blower.
is on and blower is running, but burner
Blown fuse on interface board or ignition module. Replace fuse.
will not ignite.
A. If available, substitute a controller
Heating mode light is cycling on and off
known to be working for the suspect controller. If the fryer functions correctly, order replacement from FASC.
A. Failed controller.
is operating normally, but trouble light is on continuously (false
B. If available, substitute a harness
known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC.
B. Damaged controller wiring
harness.
alarm).

is ON with power
switch in OFF position. After initial startup, fryer
If available, substitute a controller known to be working for the suspect controller. If the fryer functions correctly, order replacement from FASC.
Failed controller.
continues to heat until trouble light comes on. Frypot
temperature is above 410F (210°C).
6.4 Troubleshooting the Built-in Filtration System
A. If the pump runs normally after
A. Thermal overload switch has
resetting the thermal overload switch, the pump was overheated.
tripped on an overheated motor.
Test: If the pump stopped suddenly during the filtering process, especially if after several filtering cycles, the pump motor has probably overheated. Place the filter handle in the OFF position, allow the pump to cool for at least 45 minutes, and then press the reset button on the pump motor. Attempt to activate the pump.
Always filter with the cooking oil at or near frying temperature. Allow the pump motor to cool off for about ten minutes after filtering two full frypots one after the other. Check the filter paper between filterings. Replace the paper if there is a large accumulation of sediment.
Pump won’t start.
B. Failed filter handle microswitch.
filtering.
Test: If this is a multi-pot fryer, attempt to operate the pump using a different handle. If the pump starts, the handle microswitch is either out of alignment or has failed. When the handle is placed in the ON position, the lever on the microswitch should be firmly pressed against the switch. If so, the switch has failed. If not, the switch is loose and/or misaligned.
B. If the switch is loose, tighten the
nuts and bolts holding it in place, ensuring that when the handle is placed in the ON position, the lever on the microswitch is pressed firmly against the switch.
If the switch has failed, call FASC.
Heating mode light · Pump stops during

C. Pump blockage.
C. Pump blockages are usually
caused by sediment build-up in the pump due to improperly sized or installed filter paper and failure to use the crumb screen. Call FASC to have blockage cleared.
Test: Close the drain valve. Place the filter handle in the OFF position, allow the pump to cool for at least 45 minutes, and then press the reset button on the pump motor. Pull the filter pan from the unit and then activate the pump. If the pump motor hums and then stops, the pump is blocked.
previous page.)
Ensure that filter paper is of the proper size and is installed properly, and that the crumb screen is used.
A. To properly filter, the oil should
be at or near 350°F (177°C). At temperatures lower than this, the oil becomes too thick to pass through the filter medium easily, resulting in much slower oil return and eventual overheating of the filter pump motor.
A. Cooking oil is too cold for
filtering.
B. Improperly installed or prepared
filter pan components.
Pump starts, but no
Test: Close the drain valve. Move the filter handle to the OFF position, pull the filter pan (and Power Shower, if so equipped) from the unit. Move the filter handle to the ON position. If a strong stream of air is being pumped out of the oil return port (or the Power Shower port), the problem is with the filter pan components.
B. Remove the oil from the filter pan
and replace the filter paper, ensuring that the filter screen is in place under the paper. C. If this does not correct the
or the transfer is
very slow.
problem, the filter suction tube is probably blocked. Remove the blockage using a thin, flexible wire. If unable to remove the blockage, call FASC.
A. Plugged openings or solidified
shortening in the Power Shower.
A. Clean the Power Shower per
Test: Look for oil squirting out around the Power Shower gasket but not coming out of the holes around the frame. If so, Power Shower is obstructed.
instructions in Chapter 5 of this manual. Power Shower is not
spraying properly.
B. Missing/worn o-rings and gasket
B. Verify that o-rings and gasket are
on Power Shower.
present and in good condition.
(Continued from · transfer takes place

C. Missing paper in filter pan. (This
causes too much pressure in the oil return lines, resulting in a strong flow through the Power Shower, but also squirting of oil from around the gasket.)
C. Verify that filter paper is properly
previous page.)
installed in the filter pan.
6.5 Troubleshooting the Basket Lift
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION Basket lift movement is jerky
Lubricate basket lift rods with Lubriplate™ or equivalent light white grease.
Basket lift rods need lubrication.
and/or noisy.
(Continued from



Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000
TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135
1-800-551-8633 819-5991 SEPTEMBER 2005
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No display on computer or controller. | A. Controller not turned on. | A. Press the ON/OFF switch to turn the controller on. | p.43 |
| No display on computer or controller. | B. No power to fryer. | B. Verify that the fryer is plugged in and that the circuit breaker is not tripped. | p.43 |
| No display on computer or controller. | C. Damaged computer/controller wiring harness. | C. If available, substitute a harness known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC. | p.43 |
| No display on computer or controller. | D. Failed computer/controller. | D. If available, substitute a computer/controller known to be working for the suspect computer/controller. If the fryer functions correctly, order replacement from FASC. | p.43 |
| Display shows with alarm sounding. | Damaged computer/controller wiring harness or connector. | If available, substitute a harness known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC. | p.43 |
| Display shows with alarm sounding. Heating indicator is on, but burners will not light. | A. Drain valve not fully closed. | A. Press the ON/OFF switch off, close the drain valve(s) completely, then press the ON/OFF switch on. | p.43 |
| Display shows with alarm sounding. Heating indicator is on, but burners will not light. | B. Gas valve is not turned on. | B. Turn the gas valve knob to the ON position. | p.43 |
| Display shows with alarm sounding. Heating indicator is on, but burners will not light. | C. Manual gas shut off valve closed. | C. Verify that any in-line manual shut off valve is open. Verify that gas main cut off valve is open. | p.43 |
| Display shows with alarm sounding. Heating indicator is on, but burners will not light. | D. Improperly connected quick- disconnect fitting on gas line. | D. Verify that the quick-disconnect fitting on the flexible gas line is firmly connected to the fryer. | p.43 |
| Display shows with alarm sounding. Heating indicator is on, but burners will not light. | E. Obstructed or failed combustion air blower. | E. Verify that combustion air blower is running. If not, call FASC for service. If combustion air blower is functional, clean and adjust per instructions in Chapter 5 of this manual. | p.43 |
| Display shows , heating indicator cycles on and off normally, but burners will not light and blower is not running. | A. Failed computer/controller. | A. If available, substitute a computer/controller known to be working for the suspect computer/controller. If the fryer functions correctly, order replacement from FASC. | p.44 |
| Display shows , heating indicator cycles on and off normally, but burners will not light and blower is not running. | B. Damaged computer/controller wiring harness. | B. If available, substitute a harness known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC. | p.44 |
| Fryer is slow coming out of melt cycle. Display shows a short time after coming out of melt cycle. | Dirty or obstructed combustion air blower. | Clean and adjust per instructions in Chapter 5 of this manual. | p.44 |
| Fryer is operating normally, but recovery is slow when cooking. | Dirty or obstructed combustion air blower. | Clean and adjust per instructions in Chapter 5 of this manual. | p.44 |
| Fryer is operating normally, but produces a popping sound when burners ignite. | A. Dirty or obstructed combustion air blower. | A. Clean and adjust per instructions in Chapter 5 of this manual. | p.44 |
| Fryer is operating normally, but produces a popping sound when burners ignite. | B. Dirty or obstructed gas valve vent tube (non-CE fryers only). | B. Clean per instructions in Chapter 5 of this manual. | p.44 |
| Fryer is operating normally, but produces a popping sound when burners ignite. | C. Malfunctioning combustion air blower. | C. If blower is slow to come up to speed, contact FASC for service. | p.44 |
| Display shows and alarm sounds, but fryer operates normally (false alarm). | Failed computer/controller. | If available, substitute a computer/controller known to be working for the suspect computer/controller. If the fryer functions correctly, order replacement from FASC. | p.44 |
| Computer will not go into program mode or some buttons do not actuate. | Failed computer/controller. | If available, substitute a computer/controller known to be working for the suspect computer/controller. If the fryer functions correctly, order replacement from FASC. | p.44 |
| Heat indicator is on and blower is running, but burner will not ignite. | Blown fuse on interface board or ignition module. | Replace fuse. | p.44 |
| Heat indicator off upon initial startup. Display shows or with alarm sounding. | Failed computer/controller. | If available, substitute a computer/controller known to be working for the suspect computer/controller. If the fryer functions correctly, order replacement from FASC. | p.45 |
| Power switch ON, no lights on controller, fryer does not heat. | A. No power to fryer. | A. Verify that the fryer is plugged in and that the circuit breaker is not tripped. | p.45 |
| Power switch ON, no lights on controller, fryer does not heat. | B. Damaged controller wiring harness. | B. If available, substitute a harness known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC. | p.45 |
| Power switch ON, no lights on controller, fryer does not heat. | C. Failed controller. | C. If available, substitute a controller known to be working for the suspect controller. If the fryer functions correctly, order replacement from FASC. | p.45 |
| Power light ON, trouble light ON, heating mode light OFF. | Damaged controller wiring harness. | If available, substitute a harness known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC. | p.45 |
| Power light ON, trouble light ON, heating mode light ON. Burners do not ignite. | A. Drain valve not fully closed. | A. Press the ON/OFF switch off, close the drain valve(s) completely, then press the ON/OFF switch on. | p.45 |
| Power light ON, trouble light ON, heating mode light ON. Burners do not ignite. | B. Gas valve is not turned on. | B. Turn the gas valve knob to the ON position. | p.45 |
| Power light ON, trouble light ON, heating mode light ON. Burners do not ignite. | C. Manual gas shut off valve closed. | C. Verify that any in-line manual shut off valve is open. Verify that gas main cut off valve is open. | p.45 |
| Power light ON, trouble light ON, heating mode light ON. Burners do not ignite. | D. Improperly connected quick- disconnect fitting on gas line. | D. Verify that the quick-disconnect fitting on the flexible gas line is firmly connected to the fryer. | p.45 |
| Power light ON, trouble light ON, heating mode light ON. Burners do not ignite. | E. Obstructed or failed combustion air blower. | E. Verify that combustion air blower is running. If not, call FASC for service. If combustion air blower is functional, clean and adjust per instructions in Chapter 5 of this manual. | p.45 |
| Heating mode light cycles on and off normally. Blower not running and burners will not ignite. | A. Failed controller. | A. If available, substitute a controller known to be working for the suspect controller. If the fryer functions correctly, order replacement from FASC. | p.46 |
| Heating mode light cycles on and off normally. Blower not running and burners will not ignite. | B. Damaged controller wiring harness. | B. If available, substitute a harness known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC. | p.46 |
| Fryer is operating normally, but produces popping sound when burners ignite. | A. Obstructed combustion air blower. | A. Clean and adjust per instructions in Chapter 5 of this manual. | p.46 |
| Heating mode light is on and blower is running, but burner will not ignite. | Blown fuse on interface board or ignition module. | Replace fuse. | p.46 |
| Heating mode light is cycling on and off normally and fryer is operating normally, but trouble light is on continuously (false alarm). | A. Failed controller. | A. If available, substitute a controller known to be working for the suspect controller. If the fryer functions correctly, order replacement from FASC. | p.46 |
| Heating mode light is cycling on and off normally and fryer is operating normally, but trouble light is on continuously (false alarm). | B. Damaged controller wiring harness. | B. If available, substitute a harness known to be good for the suspect harness. If the fryer functions correctly, order replacement harness from FASC. | p.46 |
| Heating mode light is ON with power switch in OFF position. After initial startup, fryer continues to heat until trouble light comes on. Frypot temperature is above 410F (210°C). | Failed controller. | If available, substitute a controller known to be working for the suspect controller. If the fryer functions correctly, order replacement from FASC. | p.47 |
| Pump won’t start. OR Pump stops during filtering. | A. Thermal overload switch has tripped on an overheated motor. Test: If the pump stopped suddenly during the filtering process, especially if after several filtering cycles, the pump motor has probably overheated. Place the filter handle in the OFF position, allow the pump to cool for at least 45 minutes, and then press the reset button on the pump motor. Attempt to activate the pump. | A. If the pump runs normally after resetting the thermal overload switch, the pump was overheated. Always filter with the cooking oil at or near frying temperature. Allow the pump motor to cool off for about ten minutes after filtering two full frypots one after the other. Check the filter paper between filterings. Replace the paper if there is a large accumulation of sediment. | p.47 |
| Pump won’t start. OR Pump stops during filtering. | B. Failed filter handle microswitch. Test: If this is a multi-pot fryer, attempt to operate the pump using a different handle. If the pump starts, the handle microswitch is either out of alignment or has failed. When the handle is placed in the ON position, the lever on the microswitch should be firmly pressed against the switch. If so, the switch has failed. If not, the switch is loose and/or misaligned. | B. If the switch is loose, tighten the nuts and bolts holding it in place, ensuring that when the handle is placed in the ON position, the lever on the microswitch is pressed firmly against the switch. If the switch has failed, call FASC. | p.47 |
| (Continued from previous page.) | C. Pump blockage. Test: Close the drain valve. Place the filter handle in the OFF position, allow the pump to cool for at least 45 minutes, and then press the reset button on the pump motor. Pull the filter pan from the unit and then activate the pump. If the pump motor hums and then stops, the pump is blocked. | C. Pump blockages are usually caused by sediment build-up in the pump due to improperly sized or installed filter paper and failure to use the crumb screen. Call FASC to have blockage cleared. Ensure that filter paper is of the proper size and is installed properly, and that the crumb screen is used. | p.48 |
| Pump starts, but no transfer takes place or the transfer is very slow. | A. Cooking oil is too cold for filtering. | A. To properly filter, the oil should be at or near 350°F (177°C). At temperatures lower than this, the oil becomes too thick to pass through the filter medium easily, resulting in much slower oil return and eventual overheating of the filter pump motor. | p.48 |
| Pump starts, but no transfer takes place or the transfer is very slow. | B. Improperly installed or prepared filter pan components. Test: Close the drain valve. Move the filter handle to the OFF position, pull the filter pan (and Power Shower, if so equipped) from the unit. Move the filter handle to the ON position. If a strong stream of air is being pumped out of the oil return port (or the Power Shower port), the problem is with the filter pan components. | B. Remove the oil from the filter pan and replace the filter paper, ensuring that the filter screen is in place under the paper. C. If this does not correct the problem, the filter suction tube is probably blocked. Remove the blockage using a thin, flexible wire. If unable to remove the blockage, call FASC. | p.48 |
| Power Shower is not spraying properly. | A. Plugged openings or solidified shortening in the Power Shower. Test: Look for oil squirting out around the Power Shower gasket but not coming out of the holes around the frame. If so, Power Shower is obstructed. | A. Clean the Power Shower per instructions in Chapter 5 of this manual. | p.48 |
| Power Shower is not spraying properly. | B. Missing/worn o-rings and gasket on Power Shower. | B. Verify that o-rings and gasket are present and in good condition. | p.48 |
| (Continued from previous page.) | C. Missing paper in filter pan. (This causes too much pressure in the oil return lines, resulting in a strong flow through the Power Shower, but also squirting of oil from around the gasket.) | C. Verify that filter paper is properly installed in the filter pan. | p.49 |
| Basket lift movement is jerky and/or noisy. | Basket lift rods need lubrication. | Lubricate basket lift rods with Lubriplate™ or equivalent light white grease. | p.49 |