
OWNER’S OPERATION AND INSTALLATION MANUAL

S26PTA AND S26NTA 20,000 TO 26,000 BTU/HR
fied installer, service agency, or the gas supplier.
Save this manual for future reference. For more information, visit www.desatech.com


Due to high temperatures, the appliance should be located out of traffic and away from furni- ture and draperies.
Do not place clothing or other flammable material on or near the appliance. Never place any objects in the fireplace.
Heater becomes very hot when running fireplace. Keep children and adults away from hot sur- faces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.
Carbon Monoxide Poisoning: Early signs of car- bon monoxide poisoning resemble the flu, with head- aches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Carefully supervise young chil- dren when they are in the room with fireplace.
Natural and Propane/LP Gas: Natural and Propane/LP gases are odorless. An odor-making agent is added to these gases. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warn- ings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.
You must operate this heater with the heater screen in place. Make sure heater screen is in place before running heater.
Keep the appliance area clear and free from combustible ma- terials, gasoline, and other flam- mable vapors and liquids.

Heater Controls (Inside Door)
Figure 1 - Vent-Free Freestanding

AIR FOR COMBUSTION
AND VENTILATION
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc.
1430 Broadway New York, NY 10018 National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy effi- cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation. Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/ pilot is a required feature for vent-free room heat- ers. The ODS/pilot shuts off the heater if there is not enough fresh air.
PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three fol- lowing ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 5 through 7 will help you classify your space and provide adequate ven- tilation.
PIEZO IGNITION SYSTEM This heater has a piezo ignitor. This system re- quires no matches, batteries, or other sources to light heater.
Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ven- tilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (vol- ume of space) If additional ventilation to adjoining room is sup- plied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the out- side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to ar- eas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, be- tween wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of these three crite- ria, you must provide additional fresh air. See Ventilation Air From Outdoors, page 7. If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Fireplace Location.
(volume of space) x 20 = (Maxi- mum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free fireplace Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Di- rect-vent draws combustion air from the outdoors and vents to the outdoors. Example: Gas water heater Btu/Hr Vent-free fireplace Btu/Hr Total Btu/Hr 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
Confined and Unconfined Space The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose vol- ume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an un- confined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3
30,000 + 26,000 = 56,000
Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space
per kw) of the aggregate input rating of all appli- ances installed in that space. Rooms communicat- ing directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space. * Adjoining rooms are communicating only if there are doorless passageways or ventilation grills be- tween them.
can support) 56,000 Btu/Hr (actual amount of Btu/Hr used) The space in the above example is a confined space because the actual Btu/Hr used is more than the maxi- mum Btu/Hr the space can support. You must pro- vide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoin- ing room. If the extra space provides an uncon- fined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7. B. Vent room directly to the outdoors. See Ventila- tion Air From Outdoors, page 7. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless pas- sageways or ventilation grills between the rooms.

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent open- ings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANS Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-con- trolled power vent. Heated air entering the attic will activate the power vent.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an uncon- fined space. You will need no additional fresh air ven- tilation.
Ventilation Air From Inside Building This fresh air would come from an adjoining un- confined space. When ventilating to an adjoining unconfined space, you must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANS Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Inlet Air Ventilated Crawl Space
Figure 3 - Ventilation Air from Outdoors
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
Ventilation Grills Into Adjoining Room,
Or Remove Door into Adjoining
Figure 2 - Ventilation Air from Inside

the floor. IMPORTANT: You must maintain mini- mum wall and ceiling clearances during installa- tion. The minimum clearances are shown in Fig- ure 4. Measure from outermost point of stove top. Minimum Wall and Ceiling Clearances (see Figure 4) A. Clearances from outermost point of stove top
to any combustible side wall should not be less than 12 inches. B. Clearances from outermost point of stove top
to any combustible back wall should not be less than 6 inches (Includes corner installations). C. Clearances from the stove top to the ceiling
should not be less than 48 inches.
Side Wall Side Wall
IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7. CHECK GAS TYPE Use correct gas type (natural or propane/LP). If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.
Side Wall Side Wall
Front of Stove Unit
Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on
Figure 4 - Minimum Clearance to Walls

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7, page 10). IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Check building codes for any special requirements for locating equipment shutoff valve to fireplaces. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from go- ing into pipe. Excess sealant in pipe could result in clogged heater valves.
Front of Stove Unit
Gas Regulator Inlet Connection
Figure 5 - Gas Regulator Location and
Gas Line Access Into Stove Cabinet
Figure 6 - External Regulator With Vent

We recommend that you install a sediment trap in supply line as shown in Figure 7. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
Propane/LP From External Regulator (11" W.C.** to 14" W.C. Pressure) Natural From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pres- sures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equip- ment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas, opening main gas valve lo- cated on or near gas meter for natural gas, or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fit- tings for leaks. Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 8, page 11).
CSA Design- Certified Equipment Shutoff Valve With 1/8" NPT Tap*
Tee Joint Pipe Nipple
Approved Flexible Gas Hose (if allowed by local codes)
Gas Regulator of Heater
Figure 7 - Gas Connection
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 26. ** Minimum inlet pressure for purpose of input adjustment.
Sediment Trap · 3" Min · Cap

Continued 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas, opening main gas valve lo- cated on or near gas meter for natural gas, or using compressed air. 3. Check all joints from gas meter to equipment shutoff valve (see Figures 9 and 10). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
Figure 10 - Checking Gas Joints
Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 8). 2. Open main gas valve located on or near gas meter for natural gas or open propane/LP sup- ply tank valve for propane/LP gas. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figures 9 and 10). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 14 and 15). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appli- ance, page 15).
Equipment Shutoff Valve Open
It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs sup- plied with heater. Place one-piece log set on grate to fit as illustrated in Figure 11. Make sure log sits flat on firebox floor (see Figure 11).
Figure 8- Equipment Shutoff Valve
One Piece Log Set
H
O
N
O
F
F
P
O
T
Figure 9 - Checking Gas Joints
Figure 11 - Installing One-Piece Log Set

Continued IMPORTANT: Make sure log does not cover any burner ports (see Figure 12).
One Piece Log Set Burner Ports
Figure 12 - Installing One-Piece Log set
INSTALLING BLOWER ACCESSORY GA3750 Tools required: Phillips screwdriver
Figure 13 - Removing Stove Top Panel
1. Remove top panel of stove by removing three screws from under top lip on each side of stove (see Figure 13). 2. Facing front of stove, carefully slide top panel forward until it is completely removed from stove (see Figure 13). 3. Disconnect power cord wires from blower motor (if connected) (see Figure 14). 4. Disconnect green ground wire from blower housing (if connected) by removing screw holding wire terminal (see Figure 14). 5. Install one plastic bushing provided in blower kit into the 1 1/2" hole in the left rear of fire- box floor. Access hole through the rectangu- lar opening in the rear panel (see Figure 15). 6. Remove the two blower mounting brackets from the rear panel by removing two screws each (see Figure 16, page 13). 7. Attach the two mounting brackets to blower housing using four screws provided in blower kit (2 for each bracket) (see Figure 16, page 13). Tighten screws securely. Place blower assem- bly temporarily on top of firebox. 8. Working from the rear of the stove, place en- tire power cord, including speed control hous- ing, in lower control compartment.
Figure 14 - Removing Wires from Blower
Figure 15 - Installing Bushing

12. Using the four screws previously removed, mount blower assembly to stove by reattach- ing blower brackets to rear panel (see Fig- ure 16). Tighten screws securely. 13. Install plastic control knob onto output shaft of speed control housing (see Figure 17). Place speed control housing just inside control com- partment door in front of stove (see Figure 17). 14. Using two screws provided in blower kit, mount blower speed control housing to mount- ing tab in left side of lower control compart- ment (see Figure 18). 15. Check to make sure that the power cord is completely clear of blower wheel and there are no foreign objects in blower wheel. 16. Carefully replace stove top panel. Align holes and replace six screws removed in step 1, page 12. 17. Peel off the backing paper and stick the sup- plied wiring diagram decal on the stove floor as shown in Figure 18. 18. Plug power cord into a convenient 3-prong grounded wall receptacle near the stove.
Figure 16 - Removing Blower Brackets
from Stove and Attaching to Blower
Blower Speed Control Housing
Figure 17 - Installing Blower Control
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105°C wire or it’s equivalent.
120 Vac. 60 Hz. . 78 Amps
On 110/115 V.A.C.
DESA Heating Products, Bowling Green, KY
Figure 18 - Routing Power Cord

5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 19). Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. 6. With control knob pressed in, press and re- lease ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 15. 7. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when re- leased, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety inter- lock system. Wait one (1) minute for sys- tem to reset before lighting pilot again. 8. Turn control knob counterclockwise
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the
gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has
been under water. Immediately call a quali- fied service technician to inspect the appli- ance and to replace any part of the control system and any gas control which has been under water.
to desired heating level. The burn- ers should light. Set control knob to any heat level between HI and LO.
Control Knob Ignitor Button
Figure 19 - Control Knob and Ignitor
Button Location

Figure 20 - Pilot
TO APPLIANCE
Shutting Off Heater Turn control knob clockwise to the OFF position.
Figure 21 - Correct Pilot Flame Pattern
Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise to the PI- LOT position.
OPERATION The thermostat control knob can be set to any comfort level between HI and LO. The ther- mostat will gradually modulate the heat out- put and flame height from higher to lower set- tings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc. Note: Selecting the HI setting with the control knob will cause the burners to remain fully on, without modulating down in most cases.
Figure 22 - Incorrect Pilot Flame Pattern
Approx. 3-6" Above Top of Logs
PROCEDURE 1. Follow steps 1 through 5 under Lighting In- structions, page 14. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 Lighting Instructions, page 14
Figure 23 - Correct Flame Pattern with
Control Knob Set to High Flame
More Than 8" Above Top of Logs
Check pilot flame pattern and burner flame pat- terns often.
PILOT FLAME PATTERN Figure 21 shows a correct pilot flame pattern. Figure 22 shows an incorrect pilot flame pattern. The incor-
Figure 24 - Incorrect Flame Pattern with
Control Knob Set to High Flame

3. Blow air through the ports/slots and holes in the burner. 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the in- jector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4. Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 26). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if com- pressed air is not available.
Injector Holder (May Be Brass or Aluminum Depending on Model)
BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater in- spected yearly by a qualified service person. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using com- pressed air no greater than 30 PSI. Your local com- puter store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 25).
Primary Air Inlet Holes (Shape of Holes May Vary by Model)
Figure 25 - Injector Holder On Outlet
Pilot Air Inlet Hole
Figure 26 - Pilot Inlet Air Hole

SERVICE HINTS
MAINTENANCE
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready. You can also visit DESA Heating Products’ tech- nical services web site at www.desatech.com
MAIN BURNER Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.
S26PTA S26NTA Btu (Variable) 20,000/26,000 20,000/26,000 Type Gas Propane/LP Only Natural Only Ignition Piezo Piezo Manifold Pressure 8" W.C. 3.0" W.C. Inlet Gas Pressure (in. of water) *
Maximum 14" 10.5" Minimum 11" 5" Dimensions, Inches (H x W x D)
Stove 24 x 27 1/4 x 17 1/4 24 x 27 1/4 x 17 1/4 Carton 22 x 31 x 31 1/2 22 x 31 x 31 1/2 Weight, pounds
Stove 66 lbs. 66 lbs. Shipping 80 lbs. 80 lbs. * For purposes of input adjustment

TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition

OBSERVED PROBLEM
REMEDY
ODS/pilot lights but flame goes out when control knob is re- leased
B) Clean ODS/pilot (see Cleaning and Maintenance, pages 16 and 17) or replace ODS/pilot assembly
Burner does not light after ODS/ pilot is lit
Burner backfiring during com- bustion
Slight smoke or odor during ini- tial operation
Moisture/condensation noticed on windows
Delayed ignition burner

OBSERVED PROBLEM
REMEDY
Heater produces a whistling noise when burner is lit
Dark residue on logs or inside of fireplace
White powder residue forming within burner box or on adja- cent walls or furniture
Heater produces a clicking/tick- ing noise just after burner is lit or shut off

POSSIBLE CAUSE
REMEDY
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
Burner flame is excessively large and is very near or touches the top of firebox



This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
KEY PART NUMBER NO. S26PTA S26NTA DESCRIPTION QTY. 1 105441-01 105441-01 Log Set 1 2 104286-01 104285-01 ODS Pilot 1 3 098249-01 098249-01 ODS Nut 2 4 109053-01 109053-01 Burner Outlet Tube 1 5 111124-01 111124-01 Burner Retainer Spring 1 6 099056-29 099056-27 Burner Orifice Injector 1 7 101329-26 101329-20 Gas Control Valve Kit 1 8 102980-01 102980-01 Burner 1 9 099387-09 099387-09 Pilot Tube 1 10 098271-10 098271-10 Ignitor Cable 1 11 101381-01 101381-01 Piezo Ignitor and Cover 1 12 098867-10 098867-14 Regulator 1 13 109052-01 109052-01 Inlet Tube 1 14 — 105990-01 Pilot Shield 1
100563-01 100563-01 Warning Plate 1 101054-01 101054-01 Lighting Instructions Plate 1



PARTS LIST MODELS S26PTA AND S26NTA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
KEY NO. PART NO. DESCRIPTION QTY. 1 108942-01CK Top Panel, Stove 1 2 ** Pedestal Stove 1 3 108934-01CK Stove Base 1 4 ** Stove Back Panel 1 5 108932-01CK Louver Panel 1 6 105657-01 Blower Bracket 2 7 107363-01 Door 1 8 ** Firebox Back Panel 1 9 ** Firebox Floor 1 10 108939-01CK Firebox Top Assembly 1 11 110419-01CK Screen Assembly 1 12 101382-01 Valve Bracket 1 13 108978-01CK Stove Top Trim 1 14 108944-01 Brass Trim, Firebox 2 15 105576-01 Knob 1 16 101386-02 Door Hinge 2 17 099230-02 Shoulder Screw 4 18 108945-01CK Heat Deflector 1
101054-01 Lighting Instructions Plate 1 100563-01 Warning Plate 1 104108-06 Metallic BlackTouch-Up Paint Kit 1
** Not a field replaceable part.

ACCESSORIES
Purchase these heater accessories from your local dealer or Parts Central (see page 27). If they can- not supply these accessories call DESA Heating Products’ Sales Department at 1-866-672-6040 for referral information. You can also write to the ad- dress listed on the back page of this manual.
EQUIPMENT SHUTOFF VALVE GA5010 For all models. Equipment shutoff valve with 1/8" NPT tap.
MANUALLY-CONTROLLED BLOWER KIT GA3750 For all models. Provides better heat distribution. Features variable speed control knob.
CLEANING KIT - CCK (Not Shown) For all models. Your vent-free gas appliance re- quires regular cleaning and maintenance to pre- vent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.
INFORMATION VIDEO - 108917-01 For all models. A care and maintenance video is available by calling 1-866-672-6040.

These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-888-619-7060 sales@portableheaterparts.com techservice@portableheaterparts.com FBD 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com Master Parts Dist. 1251 Mound Ave NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep Laporte’s Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 843-332-0191 Parts Department Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com

Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
VENT-FREE GAS PEDESTAL STOVE
DESA Heating Products warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and main- tained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Heating Products Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA Heating Products who will provide original factory replacement parts. Failure to use origi- nal factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accor- dance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUD- ING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING PRODUCTS’ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
Model · Date Purchased · 110361 01
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.