STOVE HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
(Burner System For Cast Iron Stoves)
SL30NT
formed by a qualified installer, ser- vice agency, or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Save this manual for future reference.
Patent Pending

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.
Stove becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be work- ing properly. Get fresh air at once! Have heater serviced. Some people are more af- fected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influ- ence of alcohol, and those at high altitudes.
Carefully supervise young chil- dren when they are in the room with fireplace.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
Natural Gas: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
2 104463

PRODUCT FEATURES
This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.
One Piece Log Set Inside Stove Cavity
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
Stove Door (Shown in the open position)
Gas Log Heater Base Assembly
Figure 1 - Typical Stove Cabinet Model with Comfort Glow Gas Log Heater
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269

Confined and Unconfined Space
The National Fuel Gas Code ANSI Z223.1/ NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appli- ances installed in that space and an uncon- fined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in- stalled*, through openings not furnished with doors, are considered a part of the unconfined space.
The following are excerpts from Na- tional Fuel Gas Code, ANSI Z223.1/ NFPA 54, Section 5.3, Air for Combus- tion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space
The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.
Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.
The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.
If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.
If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow For Heater Location, page 5.
4 104463

Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) =2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
(volume of space) x 20 = (maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space can support) 70,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Continued · 5 104463


This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventila- tion grills or ducts.
Figure 2 - Ventilation Air from Inside Building

Figure 3 - Ventilation Air from Outdoors
Outlet Air · 6 104463

Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The mini- mum clearances are shown in Figure 4. Measure from outermost point of stove top.
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
Minimum Wall and Ceiling Clearances (see Figure 4) A. Clearances from outermost point of stove top to any combustible side wall should not be less than 12 inches. B. Clearances from outermost point of stove top to any combustible back wall should not be less than 6 inches (In- cludes Corner Installations). C. Clearances from the stove top to the ceiling should not be less than 48 inches.
Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.
Side Wall Side Wall
Side Wall Side Wall
Front of Stove Unit
Figure 4 - Minimum Clearance to Walls and Ceiling (Stove May Vary Depending on Model)

STOVE CAVITY ASSEMBLY 1. Lift off corrugated box enclosing stove body crating. 2. Remove all screws fastening the wood frame enclosure. Spread wood frame open and lift away from plastic-bagged stove body. The bottom pieces of pal- let wood will remain bolted to the stove body. 3. Remove plastic bag from stove body. 4. Remove back panel from stove (see Figure 5). Use an adjustable wrench or a 10 mm socket. Remove six (6) bolts and washers. Keep bolts and washers to reattach back panel later.
Product Identification Label Back Stove Panel
Figure 5 - Removing Back Panel
Top of Stove Unit
Front of Stove Unit Top of Stove Unit
Front of Stove Unit
Pallet Wood Bolted to Stove Body Bottom
leveler bolts) (1) - Bottom door (1) - Top grate (1) - Hardware kit bag with fasteners 6. Carefully lay stove body on back to attach bottom components to stove body (see Figure 6). Rest stove on drop cloth or blanket to avoid scratching stove edges. 7. Remove remaining pallet wood at- tached to bottom of stove body (see Figure 7). Use an adjustable wrench to remove bolts. 8. Fasten each leg to stove with four (4) bolts. Use a flat screw driver to tighten bolt to leg. Thread bolt in tapped holes on stove body (see Figure 8 and Figure 9, page 9).
Figure 6 - Laying Down Stove On Back (Stove Style May Vary Depending on Model)
Bottom Of Stove Unit
Figure 7 - Removing Pallet Wood From The Bottom of The Stove
Door Hinge Step Bolt Hole
Door Catch Bolt With Adjustable Hex Nuts Hole
Bottom Of Stove Unit
Figure 8 - Locating Threaded Holes for Stove Bottom, Legs, and Door Attachment (Appearance May Vary Depending on Model)

Bottom Of Stove Unit Bolt
10. Attach stove door by inserting step bolt through door hinge pivot holes and into threaded hole in stove body (see Fig- ure 11). Use an adjustable wrench or a 12mm socket to fasten step bolt. Tighten step bolt until snug. Make sure door moves freely. 11. Install door catch bolt (M8 x 1.25- 55mm with two M8 hex nuts) into threaded hole on stove body (see Fig- ure 8, page 8). Use an adjustable wrench or a 12mm socket. The catch bolt has two hex nuts attached to it (see Figure 12). The top nut is a bolt stop and the bottom nut is for door leveling adjustment. 12. Check general catch bolt alignment with door claw. Make final adjustment and door leveling after stove is in nor- mal standing position. 13. Carefully lift stove back up on its four attached legs. 14. If available, install gas log heater in- side stove cavity before installing the back panel (see Installing Gas Log Heater Into Stove, page 10). 15. Fasten back panel to stove with six (6) M6 x 1 - 20mm bolts and washers. Make sure product identification label is located on the outside in lower left- hand corner.
Bottom Of Stove Unit Leg
Figure 9 - Attaching Stove Legs
Figure 10 - Attaching Stove Bottom
Stove Bottom Bolt Shoulder
Figure 11 - Attaching Stove Door (Appearance May Vary Depending on Model)
Figure 12 - Catch Bolt and Door Claw Orientation


7. Fasten heater base to stove bottom with #10-24 x .50 bolts and hex nuts pro- vided with gas log heater (see Figure 14). Attachment hardware is factory packed inside plastic bag with installa- tion manual and owner’s registration card. Push bolt through heater base mounting hole and through stove bot- tom. Connect hex nut to bolt on under- side of stove bottom. The bolt hex head is for a 5/16" socket and the hex nuts are for a 3/8" socket. If sockets are not available, use adjustable wrenches. 8. Set one-piece log on heater base as shown in Figure 15. Make sure middle section at bottom of log is seated into "U" shaped cutout in center of heater base. Log will fit securely on base. IMPORTANT: Make sure log does not cover any burner ports and does not touch the stove cavity (see Figure 16). 9. Fasten back panel to stove with six (6) M6 x 1.20mm bolts and washers. Make sure product identification label is lo- cated on the outside lower left-hand corner. 10. Place freestanding stove in desired po- sition in room. Be sure to maintain clearances to combustibles as outlined on page 7.
INSTALLING GAS LOG HEATER INTO STOVE 1. Remove log and gas log heater from carton. Note: Do not pick up gas log heater by the burner itself. This could damage heater. Always handle the gas log heater by the heater base only. 2. Remove all protective packaging applied to log and gas log heater for shipment. 3. Check all items for any shipping dam- age. If damaged, promptly inform dealer where you bought heater. 4. If not already removed, remove back panel from assembled stove body (see Figure 5, page 8). Use an adjustable wrench or a 10 mm socket. Remove six (6) bolts and washers. Keep bolts and washers to reattach back panel later. 5. Set gas log heater inside stove (see Fig- ure 13). Make sure control knob exten- sions pass through bottom front opening. 6. Align outside holes on heater base with four (4) mounting holes on the stove bottom (see Figure 13).
Figure 14 - Fastening Heater Base to Stove Drop Bottom

Middle Section at Bottom of Log Set
"U" Shaped Cutout in Chassis

Figure 15 - Installing One-Piece Stove Log Set
Burner Porting Areas (double slotted rectangular openings

Figure 13 - Placing Heater Base In Stove Cavity (Appearance May Vary Depending on Model)
Safety Pilot Location One-Piece Log Set
Figure 16 - Top View of One-Piece Log Set on Gas Log Heater

Installation must include a equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 18).
Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
We recommend that you install a sediment trap in supply line as shown in Figure 18. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contami- nants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
Front of Stove Unit
Gas Inlet Connection Access
* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 19.
Figure 17 - Gas Regulator Location and Gas Line Access Into Stove Cabinet
CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap*
The gas inlet connection for the stove heater is located on the lower right-hand side of the stove when viewed from the front of the unit. The gas connection can be made either through the bottom right side or through the lower back opening as illustrated in Figure 17. Make sure gas log heater is secured to the stove cavity assembly.
From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Approved Flexible Gas Hose (if allowed by local codes)
Tee Joint Pipe Nipple Cap
Figure 18 - Gas Connection * Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 19. **Minimum inlet pressure for purpose of input adjustment.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 19). 2. Pressurize supply piping system by either using compressed air or open- ing main gas valve located on or near gas meter. 3. Check all joints from gas meter to equipment shutoff valve (see Figure 19). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 19). 2. Open main gas valve located on or near gas meter. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Fig- ure 20). Apply noncorrosive leak de- tection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, page 13). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 13).

Pressure Testing Gas Supply Piping System
O POS
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or open- ing main gas valve located on or near gas meter. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detec- tion fluid to gas joints. Bubbles form- ing show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.
Figure 19 - Equipment Shutoff Valve


LIGHTING
C-clockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.
C-clockwise to the PILOT position. Press in control knob for five (5) sec- onds (see Figure 21). Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system. 6. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press- ing ignitor button until pilot lights. Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure on page 14.
Figure 22 - Pilot
TO APPLIANCE
Shutting Off Heater Turn control knob clockwise to the OFF position. Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise to the PILOT position.
Control Knob Ignitor Button
Figure 21- Control Knob and Ignitor Button Location
Thermocouple Pilot Burner · 13 104463

INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often.
Btu (Variable) 16,000/30,000 Type Gas Natural Gas Only Ignition Piezo Pressure Manifold 3.5" W.C. Inlet Gas Pressure (in. of water)
CONTROL OPERATION
PILOT FLAME PATTERN
Figure 23 shows a correct pilot flame pat- tern. Figure 24 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.
Maximum 10.5" Minimum* 5" Shipping Weight 28 lbs. * For input adjustment
The thermostat control knob can be set to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc. Note: Selecting the HI setting with the control knob will cause the burner to remain fully on, without modulating down in most cases.
You may feel your gas pressure is too low. If so, contact your local natural gas supplier.
TECHNICAL SERVICE
PROCEDURE
You may have further questions about instal- lation, operation, or troubleshooting. If so, contact DESA International’s Technical Ser- vice Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.
Figure 23 - Correct Pilot Flame Pattern
You can also visit DESA International’s technical service web site at www.desatech.com
Figure 24 - Incorrect Pilot Flame Pattern

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 26). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Injector Holder (May Be Brass or Aluminum Depending on Model)
The primary air inlet holes allow the proper amount of air to mix with the gas. This pro- vides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater in- spected yearly by a qualified service person.
Primary Air Inlet Holes (Shape of Holes May Vary by Model)
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly. Note: Removing the rear panel and top grates of your stove will make cleaning easier. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 25). 3. Blow air through the ports/slots and holes in the burner.
Figure 25 - Injector Holder On Outlet Burner Tube
Pilot Air Inlet Hole
Figure 26 - Pilot Inlet Air Hole

TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is released
B) Clean ODS/pilot (see Cleaning and Maintenance, page 15) or replace ODS/ pilot assembly
16 104463

POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/pilot is lit
Burner backfiring during combustion
Slight smoke or odor during initial operation
Moisture/condensation noticed on windows
Heater produces a whistling noise when burner is lit
Dark residue on logs or inside of fireplace
White powder residue forming within burner box or on adjacent walls or furniture
www.desatech.com Continued
Delayed ignition burner · 17 104463

POSSIBLE CAUSE
REMEDY
Heater produces a clicking/ticking noise just after burner is lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
18 104463

These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International at 1-866-672-6040 for referral informa- tion. You can also write to the address listed on the back page of this manual.
Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department
East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep
Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-888-619-7060 sales@portableheaterparts.com techservice@portableheaterparts.com
Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404-0275 All States 937-258-3721 OH 1-800-762-3426
Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382-4500 610-430-7717 1-800-368-0803 www.halcoenterprises.com
For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.
FBD 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com
For all models. Your vent-free gas appli- ance requires regular cleaning and mainte- nance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.
Laporte’s Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 843-332-0191 Parts Department
Master Parts Dist. 1251 Mound Ave NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com
For all models. A care and maintenance video is available by calling 1-866-672-6040.
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com
19 104463


20 104463

This list contains replaceable parts used in your stove. For replacement parts see Parts Central on page 19 of this manual.
KEY PART NO. NO. DESCRIPTION QTY.
1 104459-01 Stove Log 1 2 098249-01 Nut, M5 2 3 104384-03 Painted Base Assembly 1 4 104454-01 Bracket, Regulator 1 5 098867-14 Gas Regulator 1 6 104425-01 Inlet Tube 1 7 104424-01 Outlet Burner Tube 1 8 099056-26 Burner Orifice Injector 1 9 102843-01 Burner Clip 1 10 102980-01 Burner 1 11 101329-21 Control Valve 1 12 104472-01 Bracket 1 13 099211-01 Screw 2 14 102445-01 Piezo Ignitor 1 15 099387-13 Pilot Tube 1 16 098271-10 Ignitor Cable 1 17 104285-01 ODS Pilot (NG) 1 18 M11084-38 Screw, Hex Head (#8-18 x .38) 7
100563-01 Warning Plate 1 101054-01 Lighting Instructions Plate 1 100565-01 Warning Plate Fastener 1 101137-04 Hardware Kit 1
21 104463


22 104463

This list contains replaceable parts used in your stove. For replacement parts see Parts Central on page 19 of this manual.
KEY PART NO. NO. DESCRIPTION QTY.
1L 104171-06 Top Grate with Screen - Left (Black Only) 1 1C 104171-05 Top Grate with Screen - Center (Black Only) 1 1R 104171-07 Top Grate with Screen - Right (Black Only) 1 2 104969-01 Bottom Door (Charcoal) 1 104969-02 Bottom Door (Forest Green) 1 3 104174-03 Stove Dropped Bottom 1 4 104970-01 One Leg (Charcoal) (4 Total Per Stove) 1 104970-02 One Leg (Forest Green) (4 Total Per Stove) 1 5 104971-01 Hardware Kit 1 5-1 * Door Hinge Step Bolt With Shoulder (1 Per Unit) 1 5-2 * Door Catch Bolt M8 x 1.25 - 55mm Long With Two M8 Hex Nuts (1 Per Unit) 1 5-3 * Bottom Floor Bolts M6 x 1 - 25mm Long With Flat Washer And Lock Washer (4 Per Unit) 1 5-4 * Leg Attachment Stud, Headless, Slotted, M10 x 1.5 - 40mm Long 4 6 104178-01 Back Panel Bolts M6 x 1 - 20mm Long With Flat Washer And Lock Washer (6 Per Unit) 1 7 104968-01 Stove Back Panel (Black Only) 1
104108-08 Touch-up Spray Paint 12 oz Can (Charcoal) 1 104108-05 Touch-up Spray Paint 12 oz Can (Forest Green) 1
* Included In Hardware Kit
23 104463

Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
104463-01 Rev. D 02/02
Model · Date Purchased · 104463 01
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.