(VENT-FREE) PROPANE/LP GASp.1STOVE HEATERp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1Model SL30PT Series Thermostat Control Gas Log Heaterp.1(Burner System For Cast Iron Stoves)p.1SL30PTp.1— Do not store or use gasoline or otherp.1SAFETY INFORMATIONp.2WARNING ICON G 001 WARNINGSp.2PRODUCT IDENTIFICATIONp.3PRODUCT FEATURESp.3OPERATIONp.3SAFETY PILOTp.3PIEZO IGNITION SYSTEMp.3LOCAL CODESp.3AIR FOR COMBUSTION AND VENTILATIONp.4PROVIDING ADEQUATE VENTILATIONp.4Confined and Unconfined Spacep.4Unusually Tight Constructionp.4AIR FOR COMBUSTION AND VENTILATION Continuedp.5DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONp.5Determining if You Have a Confined or Unconfined Spacep.5VENTILATION AIRp.6Ventilation Air From Inside Buildingp.6Ventilation Air From Outdoorsp.6INSTALLATIONp.7CHECK GAS TYPEp.7CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)p.7INSTALLATION Continuedp.8CONNECTING TO GAS SUPPLYp.11Installation Items Neededp.11CHECKING GAS CONNECTIONSp.12ON POSITp.12O POSp.12Pressure Testing Gas Supply Piping Systemp.12OPERATING HEATERp.13LIGHTING INSTRUCTIONSp.13FOR YOUR SAFETYp.13READ BEFOREp.13LIGHTINGp.13TO TURN OFF GASp.13TO APPLIANCEp.13OPERATING HEATER Continuedp.14THERMOSTATp.14CONTROL OPERATIONp.14PILOT FLAME PATTERNp.14SERVICE HINTSp.14MANUAL LIGHTINGp.14PROCEDUREp.14TECHNICAL SERVICEp.14CLEANING AND MAINTENANCEp.15MAIN BURNERp.15CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLEp.15OBSERVED PROBLEMp.16POSSIBLE CAUSEp.16REMEDYp.16TROUBLESHOOTING Continuedp.17ACCESSORIESp.19CLEANING KIT - CCK (Not Shown)p.19EQUIPMENT SHUTOFF VALVE GA5010p.19PARTS LISTp.21PARTS AVAILABLE — NOT SHOWNp.21CISC CISGp.22KEEP THIS WARRANTY WARRANTY INFORMATIONp.24LIMITED WARRANTY VENT-FREE PROPANE/LP GAS LOG HEATERS AND EMPIRE STOVE CHASSISp.24INTERNATIONALp.24NOT A UPCp.24
Page 1 of the Desa Tech SL30PT user manual — — Do not store or use gasoline or other
Page 1 · click to enlarge
Page 1

(VENT-FREE) PROPANE/LP GAS

STOVE HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

Model SL30PT Series Thermostat Control Gas Log Heater

(Burner System For Cast Iron Stoves)

SL30PT

— Do not store or use gasoline or other

  • flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. — Installation and service must be per-

formed by a qualified installer, ser- vice agency, or the gas supplier.

This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* AftermarketCompletion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Patent Pending

Page 2 of the Desa Tech SL30PT user manual — WARNING ICON G 001 WARNINGS
Page 2 · click to enlarge
Page 2

SAFETY INFORMATION

  • 7. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. 8. This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues. 9. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 15. 10. Before using furniture polish, wax, carpet cleaners, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. 11. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Troubleshooting, pages 16 through 18. 12. Do not run heater
  • where flammable liquids or vapors are used or stored
  • under dusty conditions 13. Do not use this stove to cook food or burn paper or other objects. 14. Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 15. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger). 16. Turn heater off and let cool before servicing. Only a qualified service person should service and repair heater. 17. Operating heater above elevations of 4,500 feet could cause pilot outage. 18. To prevent performance problems, the use of a propane/LP tank of less than 100 lb. capacity is not recommended.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

WARNING ICON G 001 WARNINGS

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Stove becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influ- ence of alcohol, and those at high altitudes.

Carefully supervise young chil- dren when they are in the room with fireplace.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

  • 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors. 3. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 4. This heater shall not be installed in a bedroom or bathroom. 5. Do not place stove directly on carpeting, vinyl tile, or any combustible material other than wood. The stove must set on a metal or wood panel extending the full width and depth of the appliance. 6. Do not use this stove as a wood burning fireplace. Use only model SL30PT vent-free gas log heater.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to the gas. The odor helps you detect a gas leak. How- ever, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

2 104464

Page 3 of the Desa Tech SL30PT user manual — LOCAL CODES
Page 3 · click to enlarge
Page 3

PRODUCT IDENTIFICATION

PRODUCT FEATURES

OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.

One Piece Log Set Inside Stove Cavity

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sening (ODS)safety shutoff sys- tem. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

Stove Door (Shown in the open position)

Gas Log Heater Base Assembly

Figure 1 - Typical Stove Cabinet Model with Comfort Glow Gas Log Heater

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park Quincy, MA 02269

Show 4 more labels / short text on this page
Stove Body · Piezo Ignitor · Control Knob · 3 104464
Page 4 of the Desa Tech SL30PT user manual — Unusually Tight Construction
Page 4 · click to enlarge
Page 4

AIR FOR COMBUSTION AND VENTILATION

PROVIDING ADEQUATE VENTILATION

Confined and Unconfined Space

The National Fuel Gas Code ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are con- sidered a part of the unconfined space.

The following are excerpts from Na- tional Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

This heater shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

Unusually Tight Construction

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow For Heater Location, page 5.

4 104464

Page 5 of the Desa Tech SL30PT user manual — DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Page 5 · click to enlarge
Page 5

AIR FOR COMBUSTION AND VENTILATION Continued

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this work sheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) =2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

(volume of space) ÷ 50 cu. ft. = (maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

ExampleGas water heater 40,000 Btu/Hr Vent-free heater + 30,000 Btu/Hr Total = 70,000 Btu/Hr

Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space can support) 70,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Continued · 5 104464

Page 6 of the Desa Tech SL30PT user manual — Ventilation Air From Outdoors
Page 6 · click to enlarge
Page 6

AIR FOR COMBUSTION AND VENTILATION Continued

Ventilation Grills Into Adjoining Room,

VENTILATION AIR

Or Remove Door into Adjoining

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Inlet Air Ventilated Crawl Space

Figure 3 - Ventilation Air from Outdoors

Show 14 more labels / short text on this page
12" · Ventilation · Grills Into Adjoining · Room, Option 1 · Option 2 · Room, Option · 12" · Ventilated Attic · Outlet Air · Outlet Air · To Attic · To Crawl Space · Inlet Air · 6 104464
Page 7 of the Desa Tech SL30PT user manual — CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)
Page 7 · click to enlarge
Page 7

INSTALLATION

Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The mini- mum clearances are shown in Figure 4. Measure from outermost point of stove top.

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

CHECK GAS TYPE

Minimum Wall and Ceiling Clearances (see Figure 4) A. Clearances from outermost point of stove top to any combustible side wall should not be less than 12 inches. B. Clearances from outermost point of stove top to any combustible back wall should not be less than 6 inches (In- cludes Corner Installations). C. Clearances from the stove top to the ceiling should not be less than 48 inches.

Use only propane/LP gas. If your gas supply is not propane/LP gas, do not install heater. Call dealer where you bought heater for proper type heater.

CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)

  • WARNING: Never install the heater
  • in a bedroom or bathroom
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater
  • in high traffic areas
  • in windy or drafty areas

Side Wall Side Wall

Side Wall Side Wall

Front of Stove Unit

Figure 4 - Minimum Clearance to Walls and Ceiling (Stove May Vary Depending on Model)

Show 22 more labels / short text on this page
Ceiling · Front View · 48" Minimum · 12" Minimum · 12" Minimum · Top View · Back Wall · 6 " Minimum · Side View · 12 " Minimum · 12 " Minimum · Ceiling · 48" Minimum · Back Wall Corner · Wall · 6" Minimum · 6 " Minimum · Wall · 6 " Minimum · Floor · Continued · 7 104464
Page 8 of the Desa Tech SL30PT user manual — INSTALLATION Continued
Page 8 · click to enlarge
Page 8

INSTALLATION Continued

STOVE CAVITY ASSEMBLY 1. Lift off corrugated box enclosing stove body crating. 2. Remove all screws fastening the wood frame enclosure. Spread wood frame open and lift away from plastic-bagged stove body. The bottom pieces of pal- let wood will remain bolted to the stove body. 3. Remove plastic bag from stove body. 4. Remove back panel from stove (see Figure 5). Use an adjustable wrench or a 10 mm socket. Remove six (6) bolts and washers. Keep bolts and washers to reattach back panel later.

Product Identification Label Back Stove Panel

Figure 5 - Removing Back Panel

Top of Stove Unit

Front of Stove Unit Top of Stove Unit

Front of Stove Unit

5. Remove all contents from inside stove cavity. Contents include: (1) - Stove bottom (4) - Legs (Amity models include leg

Pallet Wood Bolted to Stove Body Bottom

leveler bolts) (1) - Bottom door (1) - Top grate (1) - Hardware kit bag with fasteners 6. Carefully lay stove body on back to attach bottom components to stove body (see Figure 6). Rest stove on drop cloth or blanket to avoid scratching stove edges. 7. Remove remaining pallet wood at- tached to bottom of stove body (see Figure 7). Use an adjustable wrench to remove bolts. 8. Fasten each leg to stove with four (4) bolts. Use a flat screw driver to tighten bolt to leg. Thread bolt in tapped holes on stove body (see Figure 8 and Figure 9, page 9).

Figure 6 - Laying Down Stove On Side (Stove Style May Vary Depending on Model)

Bottom Of Stove Unit

Figure 7 - Removing Pallet Wood From The Bottom of The Stove

Door Hinge Step Bolt Hole

Door Catch Bolt With Adjustable Hex Nuts Hole

Bottom Of Stove Unit

Figure 8 - Locating Threaded Holes for Stove Bottom, Legs, and Door Attachment (Appearance May Vary Depending on Model)

Show 12 more labels / short text on this page
Bolt · Drop Cloth/ Blanket · Front · Bolt Pallet Wood · Pallet Wood · Front · Leg Hole · Leg Hole · Stove Bottom Holes · Leg Hole · Leg Hole · 8 104464
Page 9 of the Desa Tech SL30PT user manual — INSTALLATION Continued
Page 9 · click to enlarge
Page 9

INSTALLATION Continued

9. Fasten stove bottom to stove with four (4) M6 x 1 - 25mm bolts. Use a flat washer and lock washer with each bolt. Tighten bolts into threaded holes on stove body (see Figure 8, page 8 and 10). Use an adjustable wrench or a 10mm socket.

10. Attach stove door by inserting step bolt through door hinge pivot holes and into threaded hole in stove body (see Fig- ure 11). Use an adjustable wrench or a 12mm socket to fasten step bolt. Tighten step bolt until snug. Make sure door moves freely. 11. Install door catch bolt (M8 x 1.25- 55mm with two M8 hex nuts) into threaded hole on stove body (see Fig- ure 8, page 8). Use an adjustable wrench or a 12mm socket. The catch bolt has two hex nuts attached to it (see Figure 12). The top nut is a bolt stop and the bottom nut is for door leveling adjustment. 12. Check general catch bolt alignment with door claw. Make final adjustment and door leveling after stove is in nor- mal standing position. 13. Carefully lift stove back up on its four attached legs. 14. If available, install gas log heater in- side stove cavity before installing the back panel (see Installing Gas Log Heater Into Stove, page 10). 15. Fasten back panel to stove with six (6) M6 x 1 - 20mm bolts and washers. Make sure product identification label is located on the outside in lower left- hand corner.

Bottom Of Stove Unit Bolt

Bottom Of Stove Unit Leg

Figure 9 - Attaching Stove Legs

Figure 10 - Attaching Stove Bottom

Stove Bottom Bolt Shoulder

Figure 11 - Attaching Stove Door (Appearance May Vary Depending on Model)

Figure 12 - Catch Bolt and Door Claw Orientation

Show 17 more labels / short text on this page
Washers · Bolt · Stove Bottom · Stove Door · Stove Door · Bolt Shoulder · Threaded Hole · Door Hinge · Door Hinge · Step Bolt · Step Bolt · Bolt Stop · Adjusting Nut · Door Claw Door · Catch Bolt · Continued · 9 104464
Page 10 of the Desa Tech SL30PT user manual — INSTALLATION Continued
Page 10 · click to enlarge
Page 10
Desa Tech SL30PT — INSTALLATION Continued diagram (page 10)
Fig. 1 · INSTALLATION Continued

7. Fasten heater base to stove bottom with #10-24 x .50 bolts and hex nuts pro- vided with gas log heater (see Figure 14). Attachment hardware is factory packed inside plastic bag with installa- tion manual and owner’s registration card. Push bolt through heater base mounting hole and through stove bot- tom. Connect hex nut to bolt on under- side of stove bottom. The bolt hex head is for a 5/16" socket and the hex nuts are for a 3/8" socket. If sockets are not available, use adjustable wrenches. 8. Set one-piece log on heater base as shown in Figure 15. Make sure middle section at bottom of log is seated into "U" shaped cutout in center of heater base. Log will fit securely on base. IMPORTANT: Make sure log does not cover any burner ports and does not touch the stove cavity (see Figure 16). 9. Fasten back panel to stove with six (6) M6 x 1.20mm bolts and washers. Make sure product identification label is located on the outside lower left-hand corner. 10. Place freestanding stove in desired po- sition in room. Be sure to maintain clearances to combustibles as outlined on page 7.

INSTALLING GAS LOG HEATER INTO STOVE 1. Remove log and gas log heater from carton. Note: Do not pick up gas log heater by the burner itself. This could damage heater. Always handle the gas log heater by the heater base only. 2. Remove all protective packaging applied to log and gas log heater for shipment. 3. Check all items for any shipping dam- age. If damaged, promptly inform dealer where you bought heater. 4. If not already removed, remove back panel from assembled stove body (see Figure 5, page 8). Use an adjustable wrench or a 10 mm socket. Remove six (6) bolts and washers. Keep bolts and washers to reattach back panel later. 5. Set gas log heater inside stove (see Fig- ure 13). Make sure control knob exten- sions pass through bottom front opening. 6. Align outside holes on heater base with four (4) mounting holes on the stove bottom (see Figure 13).

Figure 14 - Fastening Heater Base to Stove Drop Bottom

Desa Tech SL30PT — INSTALLATION Continued diagram (page 10)
Fig. 2 · INSTALLATION Continued

Middle Section at Bottom of Log Set

Desa Tech SL30PT — INSTALLATION Continued diagram (page 10)
Fig. 3 · INSTALLATION Continued

"U" Shaped Cutout in Chassis

Figure 15 - Installing One-Piece Stove Log Set

Burner Porting Areas (double slotted rectangular openings

Desa Tech SL30PT — INSTALLATION Continued diagram (page 10)
Fig. 4 · INSTALLATION Continued

Figure 13 - Placing Heater Base In Stove Cavity (Appearance May Vary Depending on Model)

Safety Pilot Location One-Piece Log Set

Figure 16 - Top View of One-Piece Log Set on Gas Log Heater

Show 5 more labels / short text on this page
Burner · Burner · Bottom Front Opening · Stove Bottom · 10 104464
Page 11 of the Desa Tech SL30PT user manual — Installation Items Needed
Page 11 · click to enlarge
Page 11

INSTALLATION Continued

The gas inlet connection for the stove heater is located on the lower right-hand side of the stove when viewed from the front of the unit. The gas connection can be made either through the bottom right side or through the lower back opening as illustrated in Figure 17. Make sure gas log heater is secured to the stove cavity assembly.

CONNECTING TO GAS SUPPLY

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 18. Pointing the vent down protects it from freezing rain or sleet.

Installation must include a equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 19).

Installation Items Needed

  • Before installing heater, make sure you have the items listed below.
  • piping (check local codes)
  • sealant (resistant to propane/LP gas)
  • equipment shutoff valve *
  • test gauge connection *
  • sediment trap
  • tee joint
  • pipe wrench * An CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessories , page 19.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Front of Stove Unit

Gas Inlet Connection Access

Figure 17 - Gas Regulator Location and Gas Line Access Into Stove Cabinet

From External Regulator (11" W.C.** to 14" W.C. Pressure)

CSA/AGA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap* Approved Flexible Gas Hose (if allowed by local codes)

Tee Joint Pipe Nipple Cap

Figure 19 - Gas Connection

* Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessories, page 19. **Minimum inlet pressure for purpose of input adjustment.

Figure 18 - External Regulator With Vent Pointing Down

Show 13 more labels / short text on this page
Back Stove Panel · Product Identification Label · Back View · Gas Log Heater · Side View · External Regulator · Propane/LP Supply Tank · Sediment Trap · 3" Minimum · Gas Regulator · Vent Pointing Down · Continued · 11 104464
Page 12 of the Desa Tech SL30PT user manual — Pressure Testing Gas Supply Piping System
Page 12 · click to enlarge
Page 12

INSTALLATION Continued

3. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Fig- ure 20). 2. Open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figure 21). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, page 13). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 13).

We recommend that you install a sediment trap in supply line as shown in Figure 19, page 11. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Lo- cate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 20). 2. Pressurize supply piping system by either using compressed air or opening propane/ LP supply tank valve. 3. Check all joints from gas meter to equip- ment shutoff valve (see Figure 21). Ap- ply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

CHECKING GAS CONNECTIONS

ON POSIT

O POS

Figure 20- Equipment Shutoff Valve

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas sup- ply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected.

Figure 21 - Checking Gas Joints

Show 7 more labels / short text on this page
Open · Equipment Shutoff Valve · Closed · Equipment Shutoff Valve · Propane/LP Supply Tank · Control Valve Location · 12 104464
Page 13 of the Desa Tech SL30PT user manual — TO TURN OFF GAS
Page 13 · click to enlarge
Page 13

OPERATING HEATER

LIGHTING INSTRUCTIONS

7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again. 8. Turn control knob counterclockwise

FOR YOUR SAFETY

READ BEFORE

LIGHTING

1. STOP! Read the safety information, column 1. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise Clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise

C-clockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

  • A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

Figure 23 - Pilot

C-clockwise to the PILOT position. Press in control knob for five (5) sec- onds (see Figure 22). Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds or less. This will allow air to bleed from the gas system. 6. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press- ing ignitor button until pilot lights. Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure, page 14.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater Turn control knob clockwise Clockwise to the OFF position. Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise Clockwise to the PILOT position.

Control Knob Ignitor Button

Figure 22- Control Knob and Ignitor Button Location

Thermocouple Pilot Burner · Continued · 13 104464

Page 14 of the Desa Tech SL30PT user manual — TECHNICAL SERVICE
Page 14 · click to enlarge
Page 14

OPERATING HEATER Continued

INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often.

SPECIFICATIONS Btu (Variable) 16,000/30,000 Type Gas Propane/LP Only Ignition Piezo Pressure Manifold 8" W.C. Inlet Gas Pressure (in. of water)

THERMOSTAT

CONTROL OPERATION

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pat- tern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.

Maximum 14" Minimum* 11" Shipping Weight 28 lbs. * For input adjustment

The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal com- fort setting will vary by household depend- ing upon the amount of space to be heated, the output of the central heating system, etc.

SERVICE HINTS

  • If pilot flame pattern is incorrect, as shown in Figure 25
  • turn heater off (see To Turn Off Gas to Appliance , page 13)
  • see Troubleshooting , pages 16 through 18
  • When Gas Pressure Is Too Low
  • pilot will not stay lit
  • burners will have delayed ignition
  • heater will not produce specified heat
  • When Gas Quality Is Bad
  • pilot will not stay lit
  • burners will produce flames and soot
  • heater will backfire when lit

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting Instructions, page 13. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 in Lighting Instructions, page 13.

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

Figure 24 - Correct Pilot Flame Pattern

TECHNICAL SERVICE

You may have further questions about in- stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).

Figure 25 - Incorrect Pilot Flame Pattern

You can also visit DESA International’s technical service web site at www.desatech.com

Show 4 more labels / short text on this page
Thermocouple Pilot Burner · Pilot Burner · Thermocouple · 14 104464
Page 15 of the Desa Tech SL30PT user manual — CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE
Page 15 · click to enlarge
Page 15

CLEANING AND MAINTENANCE

4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.
  • LOGS
  • If you remove logs for cleaning, refer to Installing Gas Log Heater into Stove, page 10, to properly replace logs.
  • Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 27). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

Injector Holder (May Be Brass or Aluminum Depending on Model)

Review your video included with your heater for additional cleaning instructions.

The primary air inlet holes allow the proper amount of air to mix with the gas. This pro- vides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

Primary Air Inlet Holes (Shape of Holes May Vary by Model)

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly. Note: Removing the rear panel and top grates of your stove will make cleaning easier. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 26). 3. Blow air through the ports/slots and holes in the burner.

Figure 26 - Injector Holder On Outlet Burner Tube

Pilot Air Inlet Hole

Figure 27 - Pilot Inlet Air Hole

Show 5 more labels / short text on this page
Burner Tube · Ports/Slots · Burner Tube · Pilot Assembly · 15 104464
Page 16 of the Desa Tech SL30PT user manual — OBSERVED PROBLEM
Page 16 · click to enlarge
Page 16

TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1. Ignitor electrode not connected to ignitor cable 2. Ignitor cable pinched or wet
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Replace ignitor cable 4. Replace piezo ignitor 5. Replace piezo ignitor 6. Replace piezo ignitor
3. Broken ignitor cable 4. Bad piezo ignitor 5. Ignitor electrode broken 6. Ignitor electrode positioned wrong

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or equipment shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open equipment shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Clean ODS/pilot (see Cleaning and Maintenance, page 15) or replace ODS/ pilot assembly 6. Replace gas control 7. Contact local propane/LP gas company
5. ODS/pilot is clogged
6. Gas regulator setting is not correct 7. Depleted gas supply

ODS/pilot lights but flame goes out when control knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 30 seconds 3. Fully open equipment shutoff valve 4. A) Contact local propane/LP gas company
3. Equipment shutoff valve not fully open 4. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot 5. Thermocouple connection loose at control valve 6. Thermocouple damaged 7. Control valve damaged

B) Clean ODS/pilot (see Cleaning and Maintenance, page 15) or replace ODS/ pilot assembly

5. Hand tighten until snug, then tighten 1/4 turn more 6. Replace thermocouple 7. Replace control valve

www.desatech.com

16 104464

Page 17 of the Desa Tech SL30PT user manual — OBSERVED PROBLEM
Page 17 · click to enlarge
Page 17

TROUBLESHOOTING Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1. Burner orifice clogged
1. Clean burner (see Cleaning and Maintenance, pa ge 15) or replace burner orifice 2. Contact local propane/LP gas company 3. Replace burner orifice
2. Inlet gas pressure is too low 3. Burner orifice diameter is too small
1. Manifold pressure is too low 2. Burner orifice clogged
1. Contact local propane/LP gas company 2. Clean burner (see Cleaning and Maintenance, pa ge 15) or replace burner orifice

Burner backfiring during combustion

1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Maintenance, pa ge 15) or replace burner orifice 2. Replace damaged burner 3. Replace gas control
2. Damaged burner 3. Gas regulator defective

Slight smoke or odor during initial operation

1. Not enough air
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance, page 15) 2. Replace gas control 3. Problem will stop after a few hours of operation
2. Gas regulator defective 3. Residues from manufacturing processes and logs curing

Moisture/condensation noticed on windows

1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and Ventilation requirements (page 4)

Heater produces a whistling noise when burner is lit

1. Turning control knob to HI position when burner is cold 2. Air in gas line
1. Turn control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local propane/LP gas company 3. Observe minimum installation clearances (see page 7) 4. Clean burner (see Cleaning and Maintenance, pa ge 15) or replace burner orifice
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice

Dark residue on logs or inside of fireplace

1. Improper log placement
1. Properly locate logs (see Installing Gas Log Heater Into Stove, page 10) 2. Eliminate source of drafts around heater
2. Drafts or other air currents affecting flame pattern 3. Air holes at burner inlet blocked
3. Clean out air holes at burner inlet. Periodically repeat as needed 4. Remove blockage or replace burner
4. Burner flame holes blocked

White powder residue forming within burner box or on adjacent walls or furniture

1. When heated, vapors from furniture polish, wax, carpet cleaners, etc. turn into white powder residue
1. Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

www.desatech.com

Delayed ignition burner · Continued · 17 104464

Page 18 of the Desa Tech SL30PT user manual — OBSERVED PROBLEM
Page 18 · click to enlarge
Page 18

TROUBLESHOOTING Continued

  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person

Heater produces unwanted odors

1. Heater burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See IMPORTANT statement above) 2. Gas leak. See Warning statement at top of page
1. Open window and ventilate room. Stop using odor causing products while heater is running
2. Locate and correct all leaks (see Checking Gas Connections , page 12)

Heater shuts off in use (ODS operates)

1. Not enough fresh air is available 2. Low line pressure 3. ODS/pilot is partially clogged
1. Open window and/or door for ventilation 2. Contact local propane/LP gas company 3. Clean ODS/pilot (see Cleaning and Maintenance, page 15)

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at top of page 2. Control valve defective
1. Locate and correct all leaks (see Checking Gas Connections , page 12) 2. Replace control valve

Gas odor during combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections , page 12)

www.desatech.com

18 104464

Page 19 of the Desa Tech SL30PT user manual — EQUIPMENT SHUTOFF VALVE GA5010
Page 19 · click to enlarge
Page 19

These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. PARTS CENTRALS

Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department

Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com

Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404-0275 All States 937-258-3721 OH 1-800-762-3426

Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-800-362-6951 sales@portableheaterparts.com techservice@portableheaterparts.com

East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep

Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382-4500 610-430-7717 1-800-368-0803 www.halcoenterprises.com

Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728-6129 908-780-9340 1-800-922-0724 www.tarantin.com

LA Porte’s Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 803-332-0191 Parts Department

FBD 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com

Heater & Fireplace Store 58 Halbe Lane Cape May Court, NJ 08210-1110 609-390-1100 Parts Department

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com

Master Parts Dist. 1251 Mound Ave NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com

ACCESSORIES

Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the ad- dress listed on the back page of this manual.

CLEANING KIT - CCK (Not Shown)

Your vent-free gas appliance requires regu- lar cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.

EQUIPMENT SHUTOFF VALVE GA5010

For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.

19 104464

Page 20 of the Desa Tech SL30PT user manual — ACCESSORIES
Page 20 · click to enlarge
Page 20
Desa Tech SL30PT — ACCESSORIES diagram (page 20)
Fig. 5

20 104464

Page 21 of the Desa Tech SL30PT user manual — PARTS AVAILABLE — NOT SHOWN
Page 21 · click to enlarge
Page 21

PARTS LIST

This list contains replaceable parts used in your stove. For replacement parts see Parts Central on page 19 of this manual.

SL30PT

KEY PART NO. NO. DESCRIPTION QTY.

1 104459-01 Stove Log 1 2 098249-01 Nut, M5 2 3 104384-03 Painted Base Assembly 1 4 104454-01 Bracket, Regulator 1 5 098867-10 Gas Regulator 1 6 104425-01 Inlet Tube 1 7 104422-02 Outlet Burner Tube 1 8 099056-19 Burner Orifice Injector 1 9 102843-01 Burner Clip 1 10 102980-01 Burner 1 11 101329-22 Control Valve 1 12 104472-01 Bracket 1 13 099211-01 Screw 2 14 102445-01 Piezo Ignitor 1 15 099387-13 Pilot Tube 1 16 098271-07 Ignitor Cable 1 17 104286-01 ODS Pilot (LP) 1 18 M11084-38 Screw, Hex Head (#8-18 x .38) 7

PARTS AVAILABLE — NOT SHOWN

100563-01 Warning Plate 1 101054-01 Lighting Instructions Plate 1 100565-01 Warning Plate Fastener 1 101137-04 Hardware Kit 1 104310-04 Information Video 1

21 104464

Page 22 of the Desa Tech SL30PT user manual — CISC CISG
Page 22 · click to enlarge
Page 22
Desa Tech SL30PT — CISC CISG diagram (page 22)
Fig. 6

CISC CISG

22 104464

Page 23 of the Desa Tech SL30PT user manual — PARTS AVAILABLE — NOT SHOWN
Page 23 · click to enlarge
Page 23

PARTS LIST

This list contains replaceable parts used in your stove. For replacement parts see Parts Central on page 19 of this manual.

CISC CISG

KEY PART NO. NO. DESCRIPTION QTY.

1L 104171-06 Top Grate with Screen - Left (Black Only) 1 1C 104171-05 Top Grate with Screen - Center (Black Only) 1 1R 104171-07 Top Grate with Screen - Right (Black Only) 1 2 104969-01 Bottom Door (Charcoal) 1 104969-02 Bottom Door (Forest Green) 1 3 104174-03 Stove Dropped Bottom 1 4 104970-01 One Leg (Charcoal) (4 Total Per Stove) 1 104970-02 One Leg (Forest Green) (4 Total Per Stove) 1 5 104971-01 Hardware Kit 1 5-1 * Door Hinge Step Bolt With Shoulder (1 Per Unit) 1 5-2 * Door Catch Bolt M8 x 1.25 - 55mm Long With Two M8 Hex Nuts (1 Per Unit) 1 5-3 * Bottom Floor Bolts M6 x 1 - 25mm Long With Flat Washer And Lock Washer (4 Per Unit) 1 5-4 * Leg Attachment Stud, Headless, Slotted, M10 x 1.5 - 40mm Long 4 6 104178-01 Back Panel Bolts M6 x 1 - 20mm Long With Flat Washer And Lock Washer (6 Per Unit) 1 7 104968-01 Stove Back Panel (Black Only) 1

PARTS AVAILABLE — NOT SHOWN

104108-08 Touch-up Spray Paint 12 oz Can (Charcoal) 1 104108-05 Touch-up Spray Paint 12 oz Can (Forest Green) 1

* Included In Hardware Kit

23 104464

Page 24 of the Desa Tech SL30PT user manual — NOT A UPC
Page 24 · click to enlarge
Page 24

KEEP THIS WARRANTY WARRANTY INFORMATION

Serial No.

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY VENT-FREE PROPANE/LP GAS LOG HEATERS AND EMPIRE STOVE CHASSIS

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA- TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

INTERNATIONAL

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com

104464-01 Rev. C 02/00

NOT A UPC

Model · Date Purchased · 104464 01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Desa Tech SL30PT

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa Tech SL30PT

Be the first to ask — other owners or our team will answer.

Original document

Desa Tech SL30PT manual PDF

24 pages·604 KB·Gas Heater·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…