OWNER’S OPERATION AND INSTALLATION MANUAL
Controlled
O
O
O
T
O
N
F
F
P
vapors and liquids in the vicinity of this or any other appliance.
by a qualified installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manu- factured (mobile) home, where not prohibited by local codes.
Save this manual for future reference.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Do not place clothing or other flammable material on or near the appliance. Never place any objects in the fireplace.
Heater becomes very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be work- ing properly. Get fresh air at once! Have heater serviced. Some people are more af- fected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influ- ence of alcohol, and those at high altitudes.
Carefully supervise young chil- dren when they are in the room with fireplace.
Natural Gas: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
You must operate this heater with the heater screen in place. Make sure heater screen is in place before running heater.
Keep the appliance area clear and free from combustible materials, gasoline, and other flammable va- pors and liquids.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
2 107434

PRODUCT FEATURES
This heater has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
H
O
N
O
O
T
F
F
P
Heater Controls (Inside Door)
Figure 1 - Vent-Free Natural Gas Stove
UNPACKING
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
This heater is designed for vent-free opera- tion. State and local codes in some areas prohibit the use of vent-free heaters.
Screen Stove Cabinet · Logs · 3 107434

Confined and Unconfined Space
The National Fuel Gas Code ANSI Z223.1/ NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appli- ances installed in that space and an unconfining space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in- stalled*, through openings not furnished with doors, are considered a part of the unconfined space.
The following are excerpts from National Fuel Gas Code ANSI Z223.1/NFPA 54, Sec- tion 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space
The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.
Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
* Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.
The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is de- fined as construction where: a. walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.
Exhaust fans, heaters, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.
If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.
If your home does not meet all of the three criteria above, proceed to Deter- mining Fresh-Air Flow For Heater Location, page 5.
4 107434

Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space) If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
(volume of space) x 20 = (Maximum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas heater logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors. 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space can support)
69,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Continued · 5 107434


This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Figure 2 - Ventilation Air from Inside Building

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventila- tion grills or ducts.
Figure 3 - Ventilation Air from Outdoors
Outlet Air · 6 107434

Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The mini- mum clearances are shown in Figure 4. Measure from outermost point of stove top.
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
Minimum Wall and Ceiling Clearances (see Figure 4) A. Clearances from outermost point of stove top to any combustible side wall should not be less than 12 inches. B. Clearances from outermost point of stove top to any combustible back wall should not be less than 6 inches (In- cludes corner installations). C. Clearances from the stove top to the ceiling should not be less than 48 inches.
Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.
Side Wall Side Wall
Side Wall Side Wall
Front of Stove Unit
Figure 4 - Minimum Clearance to Walls and Ceiling

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
We recommend that you install a sediment trap in supply line as shown in Figure 6. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 6).
* An CSA design-certified equipment shutoff valve with 1/8" NPT tap is an ac- ceptable alternative to test gauge connec- tion. Purchase the optional CSA design- certified equipment shutoff valve from your dealer. See Accessories, page 24.

CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap*

From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Approved Flexible Gas Hose (if allowed by local codes)
Figure 6 - Gas Connection * Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 24. **Minimum inlet pressure for purpose of input adjustment.
Figure 5 - Gas Regulator Location and Gas Line Access Into Stove Cabinet
8 107434

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 7). 2. Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to equipment shutoff valve (see Figure 8). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Fig- ure 7). 2. Open main gas valve located on or near gas meter. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figure 8). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 13 and 14). Check all other in- ternal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 14).
Pressure Testing Gas Supply Piping System
O POS
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter. 4. Check all joints of gas supply piping system. Apply a noncorrosive leak de- tection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.
Figure 7- Equipment Shutoff Valve
Figure 8 - Checking Gas Joints

8. Attach the two mounting brackets to blower housing using four screws pro- vided in blower kit (2 for each bracket) (see Figure 14). Tighten screws se- curely. Place blower assembly tempo- rarily on top of firebox. 9. Working from the rear of the stove, place entire power cord, including speed control housing, in lower control compartment. 10. Route ends of 3-wire power cord up from the lower control compartment through the plastic bushing, then up to the upper cavity of stove (see Figure 15, page 11). 11. Attach the terminal ends of the white and black power cord wires to the ter- minals on the blower motor (see Fig- ure 12). Push firmly. 12. Attach the terminal end of the green power cord wire to the front tab of the blower housing using screw provided (see Figure 13).

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

White Powercord Wire

13. Using the four screws previously re- moved, mount blower assembly to stove by reattaching blower brackets to rear panel (see Figure 14, page 10). Tighten screws securely. 14. Install plastic control knob onto output shaft of speed control housing (see Fig- ure 15). Place speed control housing just inside control compartment door in front of stove (see Figure 16). 15. Using two screws provided in blower kit, mount blower speed control hous- ing to mounting tab in left side of lower control compartment (see Figure 16). 16. Check to make sure that the power cord is completely clear of blower wheel and there are no foreign objects in blower wheel. 17. Carefully replace stove top panel. Align holes and replace six screws removed in step 1, page 10. Slide top trim onto top panel. Attach with two screws re- moved in step 1, page 10. 18. Peel off the backing paper and stick the supplied wiring diagram decal on the stove floor as shown in Figure 15. 19. Plug power cord into a convenient 3-prong grounded wall receptacle near the stove.
1. Remove 2 screws from rear tabs on top trim. Pull trim forward to remove (see Figure 11, page 10). 2. Remove three screws from under top lip on each side of stove to remove top panel (see Figure 11, page 10). 3. Facing front of stove, carefully slide top panel forward until it is completely removed from stove (see Figure 11, page 10). 4. Install one plastic bushing provided in blower kit into the 1 1/2" hole in the left rear of firebox floor. Access hole through the rectangular opening in the rear panel (see Figure 12, page 10). 5. Disconnect power cord wires from blower motor (if connected) (see Fig- ure 13, page 10). 6. Disconnect green ground wire from blower housing (if connected) by re- moving screw holding wire terminal (see Figure 13, page 10). 7. Remove the two blower mounting brackets from the rear panel by remov- ing two screws each (see Figure 14, page 10). 8. Attach the two mounting brackets to blower housing using four screws pro- vided in blower kit (2 for each bracket) (see Figure 14, page 10). Tighten screws securely. Place blower assem- bly temporarily on top of firebox. 9. If screen is installed, carefully lift slightly and pull forward to remove. 10. If logs are installed, carefully remove and set aside.
Blower Speed Control Housing
Figure 16 - Installing Blower Control Housing
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105°C wire or it’s equivalent.
On 110/115 V.A.C.
Speed Control Housing Control Knob
101584-05 120 Vac. 60 Hz. . 78 Amps DESA International, Bowling Green, KY
Figure 15 - Routing Power Cord

18. Connect the black wire from speed con- trol to blue wire on switch/cover assem- bly (see Figure 20). 19. Connect red wire from switch/cover assembly to remaining terminal on blower motor (see Figure 20). Push firmly. 20. Attach green wire from speed control to front tab of blower housing using screw provided (see Figure 20). Tighten securely. 21. Using the four screws previously re- moved, mount blower assembly to stove by reattaching blower brackets to rear panel (see Figure 14, page 10). Tighten screws securely. 22. Install plastic control knob onto output shaft of speed control housing (see Fig- ure 20). Place speed control housing just inside control compartment door in front of stove (see Figure 16, page 11). 23. Using two screws provided in blower kit, mount blower speed control hous- ing to mounting tab in left side of lower control compartment (see Figure 16, page 11). 24. Check to make sure that the power cord is completely clear of blower wheel and there are no foreign objects in blower wheel. 25. Carefully replace stove top panel. Align holes and replace six screws removed in step 1, page 11. Slide top trim over sides of top panel. Attach with 2 screws removed in step 1, page 11.
11. Remove three screws and cover plate from center of firebox back panel. Keep screws but discard cover plate (see Figure 17). 12. Locate thermostatic switch/cover plate assembly and wire harness supplied with blower. Attach wire harness ter- minals to terminals on thermostatic switch. Push firmly. Make sure the bot- tom hole of cover is on the opposite side from the wire harness (see Figure 18). 13. Feed terminal ends of wire harness into the hole in firebox back panel from front of firebox. Pull the ends of the harness to the top of firebox near blower (see Figure 19). 14. Align holes in the switch/cover assem- bly with holes in firebox back panel. Using 3 screws from step 11, attach assembly to firebox back panel. Tighten screws firmly (see Figure 19). 15. Working from the rear of the stove, place entire power cord, including speed control housing, in lower control compartment (see Figure 20).
Thermostatic Switch Mounted to Cover
Hole in Firebox Back Panel
Figure 19 - Assembling Thermostatic Switch and Cover to Firebox Back Panel
White Speed Control Wire
Black Speed Control Wire
Blue Switch Wire Figure 17 - Removing Cover Plate
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105°C wire or it’s equivalent.
Thermostatic Switch Mounted to Cover
Variable Fan Switch Fan Switch
110/115 V.A.C.
Speed Control Housing Control Knob
120 Vac. 60 Hz. 90 Amps DESA International, Bowling Green, KY
Figure 18 - Attaching Wire Harness to Thermostatic Switch and Cover Assembly
Figure 20 - Connecting Switch, Blower, and Speed Control Wires

INSTALLATION Continued 26. Peel off the backing paper and stick the supplied wiring diagram decal on the stove floor as shown in Figure 20, page 12. 27. Plug power cord into a convenient 3-prong grounded wall receptacle near the stove.
READ BEFORE
C-clockwise to the PILOT position. Press in control knob for five (5) sec- onds (see Figure 21). Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or less. This will allow air to bleed from the gas system. 6. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press- ing ignitor button until pilot lights. Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure, page 14.
Control Knob Ignitor Button
Figure 21 - Control Knob and Ignitor Button Location
Continued · 13 107434

INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
PROCEDURE
Figure 23 shows a correct pilot flame pat- tern. Figure 24 shows an incorrect pilot flame pattern. (Note: Appearance of pilot assembly may vary by model). The incor- rect pilot flame is not touching the thermo- couple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
C-clockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.
ACCESSORY
Light your gas appliance with the blower off. Turn the blower on to deliver heated air at the top louvers. The blower fea- tures a variable control which allows you to select the speed you desire.
Figure 22 - Pilot
If using the GA3650TA Blower Accessory: In the ON position, the blower will start when the thermostat senses a sufficient increase in firebox temperature (approxi- mately 10 to 20 minutes depending on heat setting). Note: Your gas stove and thermostat blower will not turn on and off at the same time. The stove may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will con- tinue to run. The blower will shut off after the firebox temperature decreases.
Figure 23 - Correct Pilot Flame Pattern
TO APPLIANCE
Shutting Off Heater Turn control knob clockwise Clockwise to the OFF position. Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise Clockwise to the PILOT position.
Figure 24 - Incorrect Pilot Flame Pattern
OPERATION The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal com- fort setting will vary by household depend- ing upon the amount of space to be heated, the output of the central heating system, etc.

Burner Tube Injector Holder
The primary air inlet holes allow the proper amount of air to mix with the gas. This pro- vides a clean burning flame. Keep these holes clear of dust, dirt,lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recom- mend that you clean the unit every three months during operation and have heater in- spected yearly by a qualified service person.
Primary Air Inlet Holes
Figure 27 - Injector Holder On Outlet Burner Tube
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 27). 3. Blow air through the ports/slots and holes in the burner. 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.
Approx. 3-6" Above Top of Logs
Pilot Air Inlet Hole
Figure 25 - Correct Flame Pattern with Control Knob Set to High Flame.
Figure 28 - Pilot Inlet Air Hole
More Than 8" Above Top of Logs
Figure 26 - Incorrect Flame Pattern with Control Knob Set to High Flame
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 28). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.
Review your video included with your heater for additional cleaning instructions.

TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is released
B) Clean ODS/pilot (see Cleaning and Maintenance, page 15) or replace ODS/ pilot assembly
16 107434

REMEDY
Burner does not light after ODS/pilot is lit
Burner backfiring during combustion
Slight smoke or odor during initial operation
Moisture/condensation noticed on windows
Heater produces a whistling noise when burner is lit
Dark residue on logs or inside of fireplace
White powder residue forming within burner box or on adjacent walls or furniture
www.desatech.com Continued
Delayed ignition burner · 17 107434

POSSIBLE CAUSE
REMEDY
Heater produces a clicking/ticking noise just after burner is lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
Burner flame is excessively large and is very near or touches the top of firebox
18 107434

PARTS CENTRALS
These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. Btu (Variable) 20,000/39,000 Type Gas Natural Only Ignition Piezo Manifold Pressure 3.5" W.C. Inlet Gas Pressure (in. of water) *
Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department
Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728-6129 908-780-9340 1-800-922-0724 www.tarantin.com
Maximum 10.5" Minimum 5" Dimensions, Inches (H x W x D)
Stove 31 x 32 x 19 1/4 Carton 24 x 31 1/2 x 35 1/4 Weight, pounds
Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-800-362-6951 sales@portableheaterparts.com techservice@portableheaterparts.com
Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404-0275 All States 937-258-3721 OH 1-800-762-3426
Stove 78 lbs. Shipping 95 lbs.
* For purposes of input adjustment
Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382-4500 610-430-7717 1-800-368-0803 www.halcoenterprises.com
FBD 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com
Laporte’s Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 803-332-0191 Parts Department
You may feel your gas pressure is too low. If so, contact your local natural gas supplier.
Master Parts Dist. 1251 Mound Ave NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com
You may have further questions about in- stallation, operation, or troubleshooting.
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com
If so, contact DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).
You can also visit DESA International’s technical services web site at www.desatech.com
East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep
19 107434


20 107434

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.
KEY PART NO. NUMBER DESCRIPTION QTY.
1 107433-02 Log Set 1 2 104285-01 ODS Pilot (NG) 1 3 098249-01 ODS Nut 2 4 107090-01 Burner Outlet Tube 1 5 107089-01 Inlet Tube 1 6 102843-01 Burner Clip 1 7 099056-16 Burner Orifice Injector 1 8 101329-20 Gas Control Valve 1 9 102772-01 Burner 1 10 099387-09 Pilot Tube 1 11 098271-07 Ignitor Cable 1 12 101381-01 Piezo Ignitor and Cover 1 13 105990-01 Pilot Shield 1 14 098867-09 Regulator 1
21 107434


22 107434

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.
KEY NO. PART NO. DESCRIPTION QTY.
1 107085-01CK Top Panel, Stove 1 2 107077-01CK Pedestal Stove Assembly 1 3 107076-01CK Stove Base 1 4 107075-01CK Stove Back Panel 1 5 107082-01CK Top Trim 1 6 105657-01 Blower Bracket 2 7 107363-01CK Door 1 8 107078-01CJ Firebox Back Panel 1 9 107080-01CK Firebox Floor 1 10 107081-01CJ Firebox Top 1 11 107365-01CK Screen Assembly 1 12 101382-01 Valve Bracket 1 13 107092-01 Brass Trim, Bottom 1 14 107093-01 Brass Trim, Firebox 1 15 105576-01 Knob 1 16 101386-02 Door Hinge 2 17 099230-02 Shoulder Screw 4 18 107079-01CJ Heat Deflector 1 19 102455-12 Louver, Small 2 20 102455-13 Louver, Large 1 21 107091-01CK Support, End Louver 2 22 107084-01CK Support, Center Louver 2 23 101514-01CK Blower Sensor Cover 1 24 103158-01 Magnet Catch 1 25 107083-01 Magnet Bracket 1 26 098304-03 Louver Screw 12
101054-01 Lighting Instructions Plate 1 100563-01 Warning Plate 1 104310-12 Information Video 1 104108-06 Touch-Up Paint Kit 1
23 107434

ACCESSORIES Purchase these heater accessories from your local dealer or Parts Central (see page 19). If they cannot supply these accessories call DESA International’s Sales Department at 1-800-458-2472 for referral information. You can also write to the address listed on the back page of this manual.
Your vent-free gas appliance requires regu- lar cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Technical Service Department at 1-800-323-5190 for referral information.
Usually, we will ask you to return the defec- tive part to the factory.
Equipment shutoff valve with 1/8" NPT tap.
Contact authorized dealers of this product or Parts Central (see page 17). If they can’t supply original replacement part(s) call DESA International’s Parts Department at 1-800-972-7879 for referral information.
Provides better heat distribution. Features variable speed control knob.
Provides better heat distribution. Features variable speed control knob.
24 107434


Serial No.
Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MER- CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
107434-01 Rev. B 06/01