Propane/LP and Natural Gas Thermostat Control Gas Log Heaters (Burner System For Cast Iron Stoves)
fied installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appli- ance is not convertible for use with other gases.
Save this manual for future reference. Save this manual for future reference.




Stove Door (Shown in the open position)
Figure 1 - Typical Stove Cabinet Model with Comfort Glow Gas Log Heater
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Stove Body


LOCAL CODES PRODUCT FEATURES AIR FOR COMBUSTION AND VENTILATION
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.
The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
*Available from:
American National Standards Institute, Inc.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.
OPERATION This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmo- sphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable win- dows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, be- tween wall panels, at penetrations for plumbing, elec- trical, and gas lines, and at other openings.
SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 6.
If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Heater Loca- tion, page 5.
Today’s homes are built more energy efficient than ever. New materi- als, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
The National Fuel Gas Code ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


AIR FOR COMBUSTION AND VENTILATION Determining Fresh-Air Flow for Heater Location
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air From Out- doors, page 6.
Use this work sheet to determine if you have a confined or uncon- fined space.
C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Length x Width x Height = cu. ft. (volume of space)
Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or open- ings, add the volume of these rooms to the total volume of the space.
(volume of space) x 20 = (maximum Btu/Hr the space can support)
Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Vent-free heater Btu/Hr
Gas water heater* Btu/Hr
Gas furnace Btu/Hr
Vented gas heater Btu/Hr
Gas fireplace logs Btu/Hr
Other gas appliances* + Btu/Hr

Total = Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws com- bustion air from the outdoors and vents to the outdoors.
Btu/Hr (maximum the space can support)
Btu/Hr (actual amount of Btu/Hr used)
70,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/ Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
Figure 2 - Ventilation Air from Inside Building
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


STOVE TOP
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Top of Wood Frame Enclosure
Back of Wood Frame Enclosure


Figure 4 - Unpacking Stove from Wooden Shipping Enclosure
Figure 3 - Ventilation Air from Outdoors

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
1. Lift off corrugated box enclosing stove body crating. 2. Remove screws fastening back and top of wood frame enclo- sure. Two or more people must carefully lift stove up and out of wooden crate. 3. Remove plastic bag from stove body. 4. Remove back panel from stove (see Figure 4). Use an adjust- able wrench or a 10 mm socket. Remove four (4) bolts and washers. Keep bolts and washers to reattach back panel later. 5. Remove bubble-wrapped log set, rod and screen from stove. Remove all protective packaging applied for shipment. 6. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater. Some fiber flakes may fall from logs. This is acceptable. 7. Place freestanding stove near desired location in room.
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Back Panel Screws · Back Panel Screws · Outlet Air




Use the correct gas type (natural or propane/LP) for your unit. If your stove heater gas type is different from your house gas type, do not install heater. Call dealer where you bought heater for proper type heater.
Front of Stove Unit
Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. DO NOT place stove directly on carpeting, vinyl tile or any combustible material other than wood. The stove must be set on a metal or wood panel extending the full width and depth of the stove for these floor coverings. IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 5. Measure from outermost point of stove top.
Minimum Wall and Ceiling Clearances (see Figure 5) A. Clearances from outermost point of stove top to any combus- tible side wall should not be less than 12 inches. B. Clearances from outermost point of stove top to any combus- tible back wall should not be less than 6 inches (includes cor- ner installations). C. Clearances from the stove top to the ceiling should not be less than 48 inches.
Front of Stove Unit
Figure 5 - Minimum Clearance to Walls and Ceiling (Stove May Vary Depending on Model)
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com




Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 8, page 9).
Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Back View Side View
Back Stove Panel Front of Stove Unit
Gas Inlet Connection Access
Figure 6 - Gas Regulator Location and Gas Line Access Into Stove Cabinet

The gas inlet connection for the stove heater is located on the lower right-hand side of the stove when viewed from the front of the unit. The gas connection can be made either through the bottom right side or through the lower back opening as illustrated in Figure 6. Make sure gas log heater is secured to the stove cavity assembly.
For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 7. Pointing the vent down protects it from freezing rain or sleet.
Figure 7 - External Regulator For Propane/LP Gas With Vent Pointing Down
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Product Identification Label · Gas Log Heater



We recommend that you install a sediment trap in supply line as shown in Figure 8. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping sys- tem. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/ LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.
CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap*
From External Regulator (11" W.C.** to 14" W.C. Pressure)

Approved Flexible Gas Hose (if allowed by local codes)
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 9). 2. Pressurize supply piping system by either opening propane/ LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 3. Check all joints from gas meter for natural or propane/LP sup- ply to equipment shutoff valve (see Figure 10 or 11, page 10). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.
Figure 8 - Gas Connection
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 17. **Minimum inlet pressure for purpose of input adjustment.
ON POSIT

Figure 9 - Equipment Shutoff Valve
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 9, page 9). 2. Open main gas valve located on or near gas meter for natural gas or open propane.LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figure 10 or 11). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, page 11). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 11).
INSTALLING ROD AND SCREEN 1. Insert rod through small rings located at top of screen (see Figure 12). 2. From back of stove, insert rod into hole located inside right front of stove as shown in Figure 13. 3. Slip left side of rod down into slot on inside left front of stove (see Figure 13).


Figure 12 - Assembling Rod and Screen
Rod with Screen Assembled

Figure 10 - Checking Gas Joints on Propane/LP Gas Unit

Figure 13 - Installing Screen Into Stove (View From Back of Stove)
Figure 11 - Checking Gas Joints on Natural Gas Unit
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Equipment Shutoff Valve · Propane/LP Supply Tank


INSTALLATION Installing Log Set OPERATING HEATER For Your Safety Read Before Lighting
OPERATING HEATER

INSTALLING LOG SET 1. Set one-piece log on heater base as shown in Figure 12. Make sure middle section at bottom of log is seated into "U" shaped cutout in center of heater base. Log will fit securely on base. IMPORTANT: Make sure log does not cover any burner ports and does not touch the stove cavity (see Figure 14). 2. Fasten back panel to stove with four (4) bolts and washers re- moved in step 4 of Unpacking, page 6. Make sure product iden- tification label is located on the outside lower left-hand corner. 3. Place freestanding stove in desired position being careful not to damage gas connections. Be sure to maintain clearances to combustibles and wall clearances as outlined on page 7.

Middle Section at Bottom of Log Set
"U" Shaped Cutout in Chassis

Figure 14 - Installing One-Piece Stove Log Set
Burner Porting Areas (double slotted rectangular openings

1. STOP! Read the safety information, abovc. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise Clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, above. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise C-clockwise to the PI- LOT position. Press in control knob for five (5) seconds (see Figure 16, page 12).
Figure 15 - Top View of One-Piece Log Set on Gas Log Heater
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


Lighting Instructions (Cont.) To Turn Off Gas To Appliance Thermostat Control Operation Manual Lighting Procedure INSPECTING BURNERS
Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system. 6. With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, column 2. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for sys- tem to reset before lighting pilot again. 8. Turn control knob counterclockwise C-clockwise to desired heat- ing level. The burners should light. Set control knob to any heat level between HI and LO.
OPERATION
The thermostat control knob can be set to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
PROCEDURE

Check pilot flame pattern and burner flame patterns often.
Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
Figure 16 - Control Knob and Ignitor Button Location
Thermocouple Pilot Burner Pilot Burner
Figure 17 - Pilot
TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise Clockwise to the OFF position. Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise Clockwise to the PILOT position.
Figure 19 - Incorrect Pilot Flame Pattern (Propane/LP Shown)
Figure 18 - Correct Pilot Flame Pattern (Propane/LP Shown)
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Thermocouple Pilot Burner · Thermocouple


INSPECTING BURNERS CLEANING AND MAINTENANCE Cleaning Burner Injector Holder and Pilot Air Inlet Hole
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 21). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Injector Holder (May Be Brass or Aluminum Depending on Model)
Primary Air Inlet Holes (Shape of Holes May Vary by Model)
Figure 20 - Injector Holder On Outlet Burner Tube
The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.
Pilot Air Inlet Hole
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly. Note: Removing the rear panel and top grates of your stove will make cleaning easier. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 20). 3. Blow air through the ports/slots and holes in the burner.
Figure 21 - Pilot Inlet Air Hole
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com



POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is released
B) Clean ODS/pilot (see Cleaning and Maintenance, page 13) or replace ODS/ pilot assembly
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


POSSIBLE CAUSE
REMEDY
Burner does not light after ODS/pilot is lit
Burner backfiring during combustion
Slight smoke or odor during initial operation
Moisture/condensation noticed on windows
Heater produces a whistling noise when burner is lit
Dark residue on logs or inside of fireplace
White powder residue forming within burner box or on adjacent walls or furniture
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Delayed ignition burner



POSSIBLE CAUSE
REMEDY
Heater produces a clicking/ticking noise just after burner is lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


SERVICE HINTS
CSBPT, CSPBPT, CSPIPT (Includes SL30PT Burner Chassis) Btu (Variable) 16,000/30,000 Type Gas Propane/LP Only Ignition Piezo Pressure Manifold 8" W.C. Inlet Gas Pressure (in. of water)
You may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.
Maximum 14" Minimum* 11" Shipping Weight 265 lbs. * For input adjustment CSBNT, CSPBNT, CSPINT (Includes SL30NT Burner Chassis) Btu (Variable) 16,000/30,000 Type Gas Natural Gas Only Ignition Piezo Pressure Manifold 3.5" W.C. Inlet Gas Pressure (in. of water)
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.
You can also visit DESA Heating Products’ technical service web site at www.desatech.com
Maximum 10.5" Minimum* 5" Shipping Weight 265 lbs. * For input adjustment
Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA Heating Products at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.
PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040.
For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.
For all models. Your vent-free gas appliance requires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
For all models. A care and maintenance video is available by calling 1-866-672-6040. You may also email your request to productsupport@desaint.com.
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com



111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


This list contains replaceable parts used in your stove. For replace- ment parts see Replacement Parts on page 17 of this manual.
KEY PART NUMBER NO. SL30PT SL30NT DESCRIPTION QTY.
1 104026-02 104026-02 Stove Log 1 2 098249-01 098249-01 Nut, M5 2 3 ** Painted Base Assembly 1 4 104454-01 104454-01 Bracket, Regulator 1 5 098867-10 098867-14 Gas Regulator 1 6 104425-01 104425-01 Inlet Tube 1 7 104422-02 104424-01 Outlet Burner Tube 1 8 099056-19 099056-26 Burner Orifice Injector 1 9 111124-01 111124-01 Burner Retainer Spring 1 10 102980-01 102980-01 Burner 1 11 101329-22 101329-21 Control Valve 1 12 104472-01 104472-01 Bracket 1 13 099211-01 099211-01 Screw 2 14 102445-01 102445-01 Piezo Ignitor 1 15 099387-13 099387-13 Pilot Tube 1 16 098271-10 098271-10 Ignitor Cable 1 17 104286-01 104285-01 ODS Pilot 1 18 M11084-38 M11084-38 Screw, Hex Head (#8-18 x .38) 7
100563-01 100563-01 Warning Plate 1 101054-01 101054-01 Lighting Instructions Plate 1 100565-01 100565-01 Warning Plate Fastener 1 101137-04 101137-04 Hardware Kit 1
** Not a field replaceable part.
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com



111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


PARTS LIST Models CSB Series, CSPB Series, and CSPI Series
This list contains replaceable parts used in your stove. For replace- ment parts see Replacement Parts on page 17 of this manual.
KEY PART NUMBER NO. CSB Series CSPB Series CSPI Series DESCRIPTION QTY. (Black) (Porcelain Black) (Porcelain Ivory)
1L 111698-01 111698-02 111698-03 Top Grate - Left 1 1C 111698-07 111698-08 111698-09 Top Grate - Center 1 1R 111698-04 111698-05 111698-06 Top Grate - Right 1 2 111698-11 111698-12 111698-13 Bottom Door 1 3 111531-01CK 111531-01CK 111531-01CK Stove Dropped Pan (Black Only) 1 4 111698-14 111698-15 111698-16 Left Stove Door 1 5 111698-17 111698-18 111698-19 Right Stove Door 1 6 111698-20 111698-21 111698-22 Stove Leg 4 7 111764-01 111764-01 111764-01 Hardware Kit 1 7-1 * * * Door Hinge Step Bolt With Shoulder (1 Per Unit) With Two M8 Washers 1 7-2 * * * Door Catch Bolt M8 x 1.25 - 55mm Long With Two M8 Hex Nuts 1 7-3 * * * Leg Attachment Bolt M10 x 1.5 - 40mm Long 4 8-1 111732-01 111732-01 111732-01 Back Panel Bolts M6 x 20mm Long 4 8-2 111733-01 111733-01 111733-01 M6 Washer 4 8-3 111733-02 111733-02 111733-02 M8 Washer 4 9 111532-01CK 111532-01CK 111532-01CK Stove Back Panel (Black Only) 1 10 111698-23 111698-23 111698-23 Door Knob 1 11 103297-04 103297-04 103297-04 Screen 1 12 111533-01 111533-01 111533-01 Screen Rod 1
104108-08 — — Touch-up Spray Paint 12 oz Can, Black 1
* Included In Hardware Kit
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com
Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-888-619-7060 sales@portableheaterparts.com techservice@portableheaterparts.com
East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep
Laporte’s Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 843-332-0191 Parts Department
FBD 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com
Master Parts Dist. 1251 Mound Ave NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

23 23 • ACCESSORIES
In order to provide better customer service for this and future purchases, we recommend that you register your product with us. You can register online at www.desatech.com. If access to our website is not available to you, please complete this Owner’s Registration Form and mail to the address on the back of this owner’s manual. Please provide the following product information:
Date Purchased: Note: Keep receipt for warranty verification.
Serial Number: 7 or 9 digit number located on product or identification tag.
Address:
E-Mail:
Please answer the following questions to register your product with DESA Heating Products:
❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other
❍ 100,000 to 250,000 ❍ Over 250,000
❍ Fireplace or Hearth Shop ❍ Farm Store ❍ Other
❍ Emergency Back-Up Heat ❍ Heater was on Sale ❍ Energy Savings/High Efficiency ❍ Construction Project ❍ Other
❍ $50,000 to $74,999 ❍ $75,000 to $99,999 ❍ $100,000 and Over
Availability Price Brand Name Overall Quality Heat Output Made in USA Warranty Local Service Value for Price Prior Brand Experience Controls Location Thermostat, Remote, or Manual Operation Ease of Operation Special Features Salesperson’s Recommendation Friend/Relative’s Recommendation Portability Quiet Operation
Not Important Somewhat Important Very Important
❍
❍
❍
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com


2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
Postage Required


111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com



Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
AND CAST IRON STOVE CHASSIS
DESA Heating Products warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA Heating Products who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING PRODUCTS’ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
111487-01 Rev. A 06/03
111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com
111487 01
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.