EN
Desa Tech logo
Official user manual

Desa Tech Cast Iron Stove (CSNPT)

26 pages·2.9 MB·Stove·PDF·ENDEFRITNLJA
Desa Tech Cast Iron Stove (CSNPT)
Table of Contents 80 sections (VENT-FREE) GAS STOVE HEATER OWNER’S OPERATION AND INSTALLATION MANUAL · For more information, visit www.desatech.com For more information, visit www.desatech.com · CSBNT CSNPT CSPBNT CSPBPT CSPINT CSPIPT · — Do not store or use gasoline or other flammable · … ShowHide
(VENT-FREE) GAS STOVE HEATER OWNER’S OPERATION AND INSTALLATION MANUALp.1For more information, visit www.desatech.com For more information, visit www.desatech.comp.1CSBNT CSNPT CSPBNT CSPBPT CSPINT CSPIPTp.1— Do not store or use gasoline or other flammablep.1TABLE OF CONTENTSp.2SAFETY INFORMATION ............................................................ 2p.2TROUBLESHOOTING .............................................................. 14p.2PRODUCT IDENTIFICATION ..................................................... 3p.2SPECIFICATIONS .................................................................... 17p.2REPLACEMENT PARTS .......................................................... 17p.2LOCAL CODES........................................................................... 4p.2PRODUCT FEATURES .............................................................. 4p.2SERVICE HINTS....................................................................... 17p.2AIR FOR COMBUSTION AND VENTILATION ........................... 4p.2TECHNICAL SERVICE ............................................................. 17p.2ACCESSORIES ........................................................................ 17p.2INSTALLATION ........................................................................... 6p.2ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 18p.2PARTS CENTRALS .................................................................. 22p.2OPERATING HEATER ............................................................... 11p.2INSPECTING BURNERS.......................................................... 12p.2OWNER’S REGISTRATION FORM .......................................... 23p.2CLEANING AND MAINTENANCE ............................................ 13p.2SAFETY INFORMATIONp.2SAFETY INFORMATION Continuedp.3PRODUCT IDENTIFICATIONp.3LOCAL CODESp.4PROVIDING ADEQUATE VENTILATIONp.4PRODUCT FEATURESp.4Unusually Tight Constructionp.4AIR FOR COMBUSTION AND VENTILATIONp.4Confined and Unconfined Spacep.4Determining if You Have a Confined or Unconfined Spacep.5VENTILATION AIRp.5Ventilation Air From Inside Buildingp.5AIR FOR COMBUSTION AND VENTILATION Continuedp.6Ventilation Air From Outdoorsp.6STOVE TOPp.6STOVE BACKp.6INSTALLATIONp.6UNPACKINGp.6INSTALLATION Continuedp.7CHECK GAS TYPEp.7CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)p.7CONNECTING TO GAS SUPPLYp.8Installation Items Neededp.8Pressure Testing Gas Supply Piping Systemp.9CHECKING GAS CONNECTIONSp.9ON POSITp.9O POSp.9OPERATING HEATERp.11OPERATING HEATER Continuedp.12THERMOSTAT CONTROLp.12OPERATIONp.12MANUAL LIGHTINGp.12PROCEDUREp.12INSPECTING BURNERSp.12PILOT FLAME PATTERNp.12TO TURN OFF GASp.12TO APPLIANCEp.12Shutting Off Heaterp.12INSPECTING BURNERS Continuedp.13MAIN BURNERp.13CLEANING AND MAINTENANCEp.13CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLEp.13TROUBLESHOOTINGp.14OBSERVED PROBLEMp.14POSSIBLE CAUSEp.14REMEDYp.14TROUBLESHOOTING Continuedp.15SPECIFICATIONSp.17SERVICE HINTSp.17TECHNICAL SERVICEp.17ACCESSORIESp.17REPLACEMENT PARTSp.17EQUIPMENT SHUTOFF VALVE - GA5010p.17CLEANING KIT - CCK (Not Shown)p.17INFORMATION VIDEO - 108917-01p.17PARTS NOT UNDER WARRANTYp.17ILLUSTRATED PARTS BREAKDOWNp.18
Page 1 of the Desa Tech Cast Iron Stove (CSNPT) user manual — — Do not store or use gasoline or other flammable
Page 1 · click to enlarge
Page 1

(VENT-FREE) GAS STOVE HEATER OWNER’S OPERATION AND INSTALLATION MANUAL

Desa Tech Cast Iron Stove (CSNPT) — (VENT-FREE) GAS STOVE HEATER OWNER’S OPERATION AND INSTALLATION MANUAL diagram (page 1)
Fig. 1

For more information, visit www.desatech.com For more information, visit www.desatech.com

Desa Tech Cast Iron Stove (CSNPT) — For more information, visit www.desatech.com For more information, visit www.desatech.com diagram (page 1)
Fig. 2 · For more information, visit www.desatech.com For mor…

CSBNT CSNPT CSPBNT CSPBPT CSPINT CSPIPT

Propane/LP and Natural Gas Thermostat Control Gas Log Heaters (Burner System For Cast Iron Stoves)

— Do not store or use gasoline or other flammable

  • vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a quali-

fied installer, service agency, or the gas supplier.

This appliance may be installed in an aftermarket*, permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appli- ance is not convertible for use with other gases.

* AftermarketCompletion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference. Save this manual for future reference.

Page 2 of the Desa Tech Cast Iron Stove (CSNPT) user manual — Table of Contents
Page 2 · Contents
Contents

Contents

(VENT-FREE) GAS STOVE HEATER OWNER’S OPERATION AND INSTALLATION MANUALp.1For more information, visit www.desatech.com For more information, visit www.desatech.comp.1CSBNT CSNPT CSPBNT CSPBPT CSPINT CSPIPTp.1— Do not store or use gasoline or other flammablep.1TABLE OF CONTENTSp.2SAFETY INFORMATION ............................................................ 2p.2TROUBLESHOOTING .............................................................. 14p.2PRODUCT IDENTIFICATION ..................................................... 3p.2SPECIFICATIONS .................................................................... 17p.2REPLACEMENT PARTS .......................................................... 17p.2LOCAL CODES........................................................................... 4p.2PRODUCT FEATURES .............................................................. 4p.2SERVICE HINTS....................................................................... 17p.2AIR FOR COMBUSTION AND VENTILATION ........................... 4p.2TECHNICAL SERVICE ............................................................. 17p.2ACCESSORIES ........................................................................ 17p.2INSTALLATION ........................................................................... 6p.2ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 18p.2PARTS CENTRALS .................................................................. 22p.2OPERATING HEATER ............................................................... 11p.2INSPECTING BURNERS.......................................................... 12p.2OWNER’S REGISTRATION FORM .......................................... 23p.2CLEANING AND MAINTENANCE ............................................ 13p.2SAFETY INFORMATIONp.2SAFETY INFORMATION Continuedp.3PRODUCT IDENTIFICATIONp.3LOCAL CODESp.4PROVIDING ADEQUATE VENTILATIONp.4PRODUCT FEATURESp.4Unusually Tight Constructionp.4AIR FOR COMBUSTION AND VENTILATIONp.4Confined and Unconfined Spacep.4Determining if You Have a Confined or Unconfined Spacep.5VENTILATION AIRp.5Ventilation Air From Inside Buildingp.5AIR FOR COMBUSTION AND VENTILATION Continuedp.6Ventilation Air From Outdoorsp.6STOVE TOPp.6STOVE BACKp.6INSTALLATIONp.6UNPACKINGp.6INSTALLATION Continuedp.7CHECK GAS TYPEp.7CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)p.7CONNECTING TO GAS SUPPLYp.8Installation Items Neededp.8Pressure Testing Gas Supply Piping Systemp.9CHECKING GAS CONNECTIONSp.9ON POSITp.9O POSp.9OPERATING HEATERp.11OPERATING HEATER Continuedp.12THERMOSTAT CONTROLp.12OPERATIONp.12MANUAL LIGHTINGp.12PROCEDUREp.12INSPECTING BURNERSp.12PILOT FLAME PATTERNp.12TO TURN OFF GASp.12TO APPLIANCEp.12Shutting Off Heaterp.12INSPECTING BURNERS Continuedp.13MAIN BURNERp.13CLEANING AND MAINTENANCEp.13CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLEp.13TROUBLESHOOTINGp.14OBSERVED PROBLEMp.14POSSIBLE CAUSEp.14REMEDYp.14TROUBLESHOOTING Continuedp.15SPECIFICATIONSp.17SERVICE HINTSp.17TECHNICAL SERVICEp.17ACCESSORIESp.17REPLACEMENT PARTSp.17EQUIPMENT SHUTOFF VALVE - GA5010p.17CLEANING KIT - CCK (Not Shown)p.17INFORMATION VIDEO - 108917-01p.17PARTS NOT UNDER WARRANTYp.17ILLUSTRATED PARTS BREAKDOWNp.18
Page 3 of the Desa Tech Cast Iron Stove (CSNPT) user manual — PRODUCT IDENTIFICATION
Page 3 · click to enlarge
Page 3
Desa Tech Cast Iron Stove (CSNPT) — SAFETY INFORMATION Continued diagram (page 3)
Fig. 3 · SAFETY INFORMATION Continued

SAFETY INFORMATION Continued

  • 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. 3. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 4. This heater shall not be installed in a bedroom or bathroom. 5. Do not place stove directly on carpeting, vinyl tile, or any combustible material other than wood. The stove must set on a metal or wood panel extending the full width and depth of the appliance. 6. Do not use this stove as a wood burning fireplace. Use only model SL30NT/SL30PT vent-free gas log heater. 7. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. 8. This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues. 9. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 13. 10. Before using furniture polish, wax, carpet cleaners, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. 11. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Troubleshooting, pages 14 through 16. 12. Do not run heater
  • where flammable liquids or vapors are used or stored
  • when under dusty conditions 13. Do not use this stove to cook food or burn paper or other objects. 14. Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 15. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime-sized or larger).
16. Turn heater off and let cool before servicing. Only a qualified service person should service and repair heater. 17. Operating heater above elevations of 4,500 feet could cause pilot outage. 18. For propane/LP units, do not use propane/LP tank of less than 100 lb. capacity. 19. Provide adequate clearances around air openings. 20. Screen must be completely closed before using heater. Never run heater with screen open.

PRODUCT IDENTIFICATION

Desa Tech Cast Iron Stove (CSNPT) — PRODUCT IDENTIFICATION diagram (page 3)
Fig. 4

Stove Door (Shown in the open position)

Figure 1 - Typical Stove Cabinet Model with Comfort Glow Gas Log Heater

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Stove Body

Page 4 of the Desa Tech Cast Iron Stove (CSNPT) user manual — Confined and Unconfined Space
Page 4 · click to enlarge
Page 4
Desa Tech Cast Iron Stove (CSNPT) — LOCAL CODES diagram (page 4)
Fig. 5

LOCAL CODES PRODUCT FEATURES AIR FOR COMBUSTION AND VENTILATION

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.

*Available from:

American National Standards Institute, Inc.

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space

1430 Broadway New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park Quincy, MA 02269

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

PRODUCT FEATURES

OPERATION This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmo- sphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable win- dows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, be- tween wall panels, at penetrations for plumbing, elec- trical, and gas lines, and at other openings.

SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

AIR FOR COMBUSTION AND VENTILATION

Desa Tech Cast Iron Stove (CSNPT) — AIR FOR COMBUSTION AND VENTILATION diagram (page 4)
Fig. 6

If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Heater Loca- tion, page 5.

Confined and Unconfined Space

Today’s homes are built more energy efficient than ever. New materi- als, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

The National Fuel Gas Code ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 5 of the Desa Tech Cast Iron Stove (CSNPT) user manual — Ventilation Air From Inside Building
Page 5 · click to enlarge
Page 5
Desa Tech Cast Iron Stove (CSNPT) — Determining if You Have a Confined or Unconfined Space diagram (page 5)
Fig. 7 · Determining if You Have a Confined or Unconfined Spa…

AIR FOR COMBUSTION AND VENTILATION Determining Fresh-Air Flow for Heater Location

AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.

Determining if You Have a Confined or Unconfined Space

B. Vent room directly to the outdoors. See Ventilation Air From Out- doors, page 6.

Use this work sheet to determine if you have a confined or uncon- fined space.

C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

1. Determine the volume of the space (length x width x height).
Desa Tech Cast Iron Stove (CSNPT) — Determining if You Have a Confined or Unconfined Space diagram (page 5)
Fig. 8 · Determining if You Have a Confined or Unconfined Spa…

Length x Width x Height = cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or open- ings, add the volume of these rooms to the total volume of the space.

2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.

VENTILATION AIR

(volume of space) x 20 = (maximum Btu/Hr the space can support)

Ventilation Air From Inside Building

Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

3. Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater Btu/Hr

Gas water heater* Btu/Hr

Gas furnace Btu/Hr

Vented gas heater Btu/Hr

Gas fireplace logs Btu/Hr

Other gas appliances* + Btu/Hr

Desa Tech Cast Iron Stove (CSNPT) — Ventilation Air From Inside Building diagram (page 5)
Fig. 9 · Ventilation Air From Inside Building

Total = Btu/Hr

* Do not include direct-vent gas appliances. Direct-vent draws com- bustion air from the outdoors and vents to the outdoors.

ExampleGas water heater _____________ Btu/Hr Vent-free heater + _____________ Btu/Hr Total = _____________ Btu/Hr
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

Btu/Hr (maximum the space can support)

Btu/Hr (actual amount of Btu/Hr used)

Example51,200 Btu/Hr (maximum the space can support)

70,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/ Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

Figure 2 - Ventilation Air from Inside Building

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 4 more labels / short text on this page
Ventilation · Grills Into Adjoining · 40,000 30,000 70,000 · Room, Option 1
Page 6 of the Desa Tech Cast Iron Stove (CSNPT) user manual — UNPACKING
Page 6 · click to enlarge
Page 6
Desa Tech Cast Iron Stove (CSNPT) — AIR FOR COMBUSTION AND VENTILATION Continued diagram (page 6)
Fig. 10 · AIR FOR COMBUSTION AND VENTILATION Continued

AIR FOR COMBUSTION AND VENTILATION Continued

Ventilation Air From Outdoors

STOVE TOP

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Desa Tech Cast Iron Stove (CSNPT) — Ventilation Air From Outdoors diagram (page 6)
Fig. 11 · Ventilation Air From Outdoors

Top of Wood Frame Enclosure

Back of Wood Frame Enclosure

Desa Tech Cast Iron Stove (CSNPT) — Ventilation Air From Outdoors diagram (page 6)
Fig. 12 · Ventilation Air From Outdoors
Desa Tech Cast Iron Stove (CSNPT) — Ventilation Air From Outdoors diagram (page 6)
Fig. 13 · Ventilation Air From Outdoors

STOVE BACK

Figure 4 - Unpacking Stove from Wooden Shipping Enclosure

INSTALLATION

Figure 3 - Ventilation Air from Outdoors

Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION diagram (page 6)
Fig. 14

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

UNPACKING

1. Lift off corrugated box enclosing stove body crating. 2. Remove screws fastening back and top of wood frame enclo- sure. Two or more people must carefully lift stove up and out of wooden crate. 3. Remove plastic bag from stove body. 4. Remove back panel from stove (see Figure 4). Use an adjust- able wrench or a 10 mm socket. Remove four (4) bolts and washers. Keep bolts and washers to reattach back panel later. 5. Remove bubble-wrapped log set, rod and screen from stove. Remove all protective packaging applied for shipment. 6. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater. Some fiber flakes may fall from logs. This is acceptable. 7. Place freestanding stove near desired location in room.

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Back Panel Screws · Back Panel Screws · Outlet Air

Page 7 of the Desa Tech Cast Iron Stove (CSNPT) user manual — CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)
Page 7 · click to enlarge
Page 7
Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION Continued diagram (page 7)
Fig. 15 · INSTALLATION Continued

INSTALLATION Continued

  • WARNING: Never install the heater
  • in a bedroom or bathroom
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater
  • in high traffic areas
  • in windy or drafty areas
Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION Continued diagram (page 7)
Fig. 16 · INSTALLATION Continued
Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION Continued diagram (page 7)
Fig. 17 · INSTALLATION Continued

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your stove heater gas type is different from your house gas type, do not install heater. Call dealer where you bought heater for proper type heater.

CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)

Front of Stove Unit

Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. DO NOT place stove directly on carpeting, vinyl tile or any combustible material other than wood. The stove must be set on a metal or wood panel extending the full width and depth of the stove for these floor coverings. IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 5. Measure from outermost point of stove top.

Minimum Wall and Ceiling Clearances (see Figure 5) A. Clearances from outermost point of stove top to any combus- tible side wall should not be less than 12 inches. B. Clearances from outermost point of stove top to any combus- tible back wall should not be less than 6 inches (includes cor- ner installations). C. Clearances from the stove top to the ceiling should not be less than 48 inches.

Front of Stove Unit

Figure 5 - Minimum Clearance to Walls and Ceiling (Stove May Vary Depending on Model)

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 14 more labels / short text on this page
Front View · Back Wall · Top View · Corner · Wall · 6 " Minimum · Wall · 6 " Minimum · Ceiling · Side View · 48" Minimum · Back Wall · 6" Minimum · Floor
Page 8 of the Desa Tech Cast Iron Stove (CSNPT) user manual — Installation Items Needed
Page 8 · click to enlarge
Page 8
Desa Tech Cast Iron Stove (CSNPT) — CONNECTING TO GAS SUPPLY diagram (page 8)
Fig. 18

INSTALLATION Continued

CONNECTING TO GAS SUPPLY

Desa Tech Cast Iron Stove (CSNPT) — CONNECTING TO GAS SUPPLY diagram (page 8)
Fig. 19
Desa Tech Cast Iron Stove (CSNPT) — CONNECTING TO GAS SUPPLY diagram (page 8)
Fig. 20

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 8, page 9).

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Installation Items Needed

Back View Side View

  • Before installing heater, make sure you have the items listed below.
  • external regulator [propane/LP only] (supplied by installer)
  • piping to stove location (check local codes)
  • sealant (resistant to propane/LP gas)
  • equipment shutoff valve *
  • test gauge connection *
  • sediment trap
  • tee joint
  • pipe wrench * A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories , page 17.

Back Stove Panel Front of Stove Unit

Gas Inlet Connection Access

Figure 6 - Gas Regulator Location and Gas Line Access Into Stove Cabinet

Desa Tech Cast Iron Stove (CSNPT) — Installation Items Needed diagram (page 8)
Fig. 21 · Installation Items Needed

The gas inlet connection for the stove heater is located on the lower right-hand side of the stove when viewed from the front of the unit. The gas connection can be made either through the bottom right side or through the lower back opening as illustrated in Figure 6. Make sure gas log heater is secured to the stove cavity assembly.

For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 7. Pointing the vent down protects it from freezing rain or sleet.

Figure 7 - External Regulator For Propane/LP Gas With Vent Pointing Down

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Product Identification Label · Gas Log Heater

Page 9 of the Desa Tech Cast Iron Stove (CSNPT) user manual — O POS
Page 9 · click to enlarge
Page 9
Desa Tech Cast Iron Stove (CSNPT) — Pressure Testing Gas Supply Piping System diagram (page 9)
Fig. 22 · Pressure Testing Gas Supply Piping System

INSTALLATION Continued

Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION Continued diagram (page 9)
Fig. 23 · INSTALLATION Continued

We recommend that you install a sediment trap in supply line as shown in Figure 8. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping sys- tem. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/ LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap*

From External Regulator (11" W.C.** to 14" W.C. Pressure)

Desa Tech Cast Iron Stove (CSNPT) — Pressure Testing Gas Supply Piping System diagram (page 9)
Fig. 24 · Pressure Testing Gas Supply Piping System

Approved Flexible Gas Hose (if allowed by local codes)

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 9). 2. Pressurize supply piping system by either opening propane/ LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 3. Check all joints from gas meter for natural or propane/LP sup- ply to equipment shutoff valve (see Figure 10 or 11, page 10). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Figure 8 - Gas Connection

* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 17. **Minimum inlet pressure for purpose of input adjustment.

CHECKING GAS CONNECTIONS

ON POSIT

Desa Tech Cast Iron Stove (CSNPT) — CHECKING GAS CONNECTIONS diagram (page 9)
Fig. 25

O POS

Figure 9 - Equipment Shutoff Valve

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 4 more labels / short text on this page
Sediment Trap · Open · Equipment Shutoff Valve · Closed
Page 10 of the Desa Tech Cast Iron Stove (CSNPT) user manual — INSTALLATION Continued
Page 10 · click to enlarge
Page 10
Desa Tech Cast Iron Stove (CSNPT) — Pressure Testing Gas Supply Piping System diagram (page 10)
Fig. 26 · Pressure Testing Gas Supply Piping System

INSTALLATION Continued

Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 9, page 9). 2. Open main gas valve located on or near gas meter for natural gas or open propane.LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figure 10 or 11). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, page 11). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 11).

INSTALLING ROD AND SCREEN 1. Insert rod through small rings located at top of screen (see Figure 12). 2. From back of stove, insert rod into hole located inside right front of stove as shown in Figure 13. 3. Slip left side of rod down into slot on inside left front of stove (see Figure 13).

Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION Continued diagram (page 10)
Fig. 27 · INSTALLATION Continued
Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION Continued diagram (page 10)
Fig. 28 · INSTALLATION Continued

Figure 12 - Assembling Rod and Screen

Rod with Screen Assembled

Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION Continued diagram (page 10)
Fig. 29 · INSTALLATION Continued

Figure 10 - Checking Gas Joints on Propane/LP Gas Unit

Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION Continued diagram (page 10)
Fig. 30 · INSTALLATION Continued

Figure 13 - Installing Screen Into Stove (View From Back of Stove)

Figure 11 - Checking Gas Joints on Natural Gas Unit

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Equipment Shutoff Valve · Propane/LP Supply Tank

Page 11 of the Desa Tech Cast Iron Stove (CSNPT) user manual — INSTALLATION Continued
Page 11 · click to enlarge
Page 11
Desa Tech Cast Iron Stove (CSNPT) — OPERATING HEATER diagram (page 11)
Fig. 31

INSTALLATION Installing Log Set OPERATING HEATER For Your Safety Read Before Lighting

INSTALLATION Continued

OPERATING HEATER

Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION Continued diagram (page 11)
Fig. 32 · INSTALLATION Continued

INSTALLING LOG SET 1. Set one-piece log on heater base as shown in Figure 12. Make sure middle section at bottom of log is seated into "U" shaped cutout in center of heater base. Log will fit securely on base. IMPORTANT: Make sure log does not cover any burner ports and does not touch the stove cavity (see Figure 14). 2. Fasten back panel to stove with four (4) bolts and washers re- moved in step 4 of Unpacking, page 6. Make sure product iden- tification label is located on the outside lower left-hand corner. 3. Place freestanding stove in desired position being careful not to damage gas connections. Be sure to maintain clearances to combustibles and wall clearances as outlined on page 7.

  • A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION Continued diagram (page 11)
Fig. 33 · INSTALLATION Continued

Middle Section at Bottom of Log Set

"U" Shaped Cutout in Chassis

Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION Continued diagram (page 11)
Fig. 34 · INSTALLATION Continued

Figure 14 - Installing One-Piece Stove Log Set

Burner Porting Areas (double slotted rectangular openings

Desa Tech Cast Iron Stove (CSNPT) — INSTALLATION Continued diagram (page 11)
Fig. 35 · INSTALLATION Continued

1. STOP! Read the safety information, abovc. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise Clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, above. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise C-clockwise to the PI- LOT position. Press in control knob for five (5) seconds (see Figure 16, page 12).

Figure 15 - Top View of One-Piece Log Set on Gas Log Heater

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 5 more labels / short text on this page
One-Piece Log Set · Burner · Heater Base · One-Piece Log Set · Safety Pilot Location
Page 12 of the Desa Tech Cast Iron Stove (CSNPT) user manual — TO TURN OFF GAS
Page 12 · click to enlarge
Page 12
Desa Tech Cast Iron Stove (CSNPT) — OPERATING HEATER Continued diagram (page 12)
Fig. 36 · OPERATING HEATER Continued

Lighting Instructions (Cont.) To Turn Off Gas To Appliance Thermostat Control Operation Manual Lighting Procedure INSPECTING BURNERS

OPERATING HEATER Continued

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system. 6. With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, column 2. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for sys- tem to reset before lighting pilot again. 8. Turn control knob counterclockwise C-clockwise to desired heat- ing level. The burners should light. Set control knob to any heat level between HI and LO.

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting Instructions, page 11. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 in Lighting Instructions, column 1.
Desa Tech Cast Iron Stove (CSNPT) — MANUAL LIGHTING diagram (page 12)
Fig. 37

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Figure 16 - Control Knob and Ignitor Button Location

  • If pilot flame pattern is incorrect, as shown in Figure 19
  • turn heater off (see To Turn Off Gas to Appliance, column 1)
  • see Troubleshooting , pages 14 through 16

Thermocouple Pilot Burner Pilot Burner

Figure 17 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise Clockwise to the OFF position. Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise Clockwise to the PILOT position.

Figure 19 - Incorrect Pilot Flame Pattern (Propane/LP Shown)

Figure 18 - Correct Pilot Flame Pattern (Propane/LP Shown)

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Thermocouple Pilot Burner · Thermocouple

Page 13 of the Desa Tech Cast Iron Stove (CSNPT) user manual — CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE
Page 13 · click to enlarge
Page 13
Desa Tech Cast Iron Stove (CSNPT) — INSPECTING BURNERS Continued diagram (page 13)
Fig. 38 · INSPECTING BURNERS Continued

INSPECTING BURNERS CLEANING AND MAINTENANCE Cleaning Burner Injector Holder and Pilot Air Inlet Hole

INSPECTING BURNERS Continued

MAIN BURNER

4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 21). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

CLEANING AND MAINTENANCE

Injector Holder (May Be Brass or Aluminum Depending on Model)

Primary Air Inlet Holes (Shape of Holes May Vary by Model)

Figure 20 - Injector Holder On Outlet Burner Tube

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

Pilot Air Inlet Hole

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly. Note: Removing the rear panel and top grates of your stove will make cleaning easier. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 20). 3. Blow air through the ports/slots and holes in the burner.

Figure 21 - Pilot Inlet Air Hole

  • LOGS
  • If you remove logs for cleaning, refer to Installing Lot Set, page 11, to properly replace logs.
  • Replace log(s) if broken or chipped (dime-sized or larger).

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 4 more labels / short text on this page
Burner Tube · Ports/Slots · Burner Tube · Pilot Assembly
Page 14 of the Desa Tech Cast Iron Stove (CSNPT) user manual — OBSERVED PROBLEM
Page 14 · click to enlarge
Page 14
Desa Tech Cast Iron Stove (CSNPT) — TROUBLESHOOTING diagram (page 14)
Fig. 39

TROUBLESHOOTING

Desa Tech Cast Iron Stove (CSNPT) — TROUBLESHOOTING diagram (page 14)
Fig. 40

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1. Ignitor electrode not connected to ignitor cable 2. Ignitor cable pinched or wet
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Replace ignitor cable 4. Replace piezo ignitor 5. Replace pilot assembly 6. Replace pilot assembly
3. Broken ignitor cable 4. Bad piezo ignitor 5. Ignitor electrode broken 6. Ignitor electrode positioned wrong

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or equipment shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open equipment shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Clean ODS/pilot (see Cleaning and Maintenance, page 13) or replace ODS/ pilot assembly 6. Replace gas control 7. Contact local propane/LP gas company
5. ODS/pilot is clogged
6. Gas regulator setting is not correct 7. Depleted gas supply (propane/LP only)

ODS/pilot lights but flame goes out when control knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 30 seconds 3. Fully open equipment shutoff valve 4. A) Contact local natural or propane/LP gas company
3. Equipment shutoff valve not fully open 4. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot 5. Thermocouple connection loose at control valve 6. Thermocouple damaged 7. Control valve damaged

B) Clean ODS/pilot (see Cleaning and Maintenance, page 13) or replace ODS/ pilot assembly

5. Hand tighten until snug, then tighten 1/4 turn more 6. Replace pilot assembly 7. Replace control valve

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 15 of the Desa Tech Cast Iron Stove (CSNPT) user manual — OBSERVED PROBLEM
Page 15 · click to enlarge
Page 15
Desa Tech Cast Iron Stove (CSNPT) — TROUBLESHOOTING Continued diagram (page 15)
Fig. 41 · TROUBLESHOOTING Continued

TROUBLESHOOTING Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1. Burner orifice clogged
1. Clean burner (see Cleaning and Maintenance, page 13) or replace burner orifice 2. Contact local natural or propane/LP gas company
2. Inlet gas pressure is too low
1. Manifold pressure is too low
1. Contact local natural or propane/LP gas company 2. Clean burner (see Cleaning and Maintenance, page 13) or replace burner orifice
2. Burner orifice clogged

Burner backfiring during combustion

1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Maintenance, page 13) or replace burner orifice 2. Replace damaged burner 3. Replace gas control
2. Damaged burner 3. Gas regulator defective

Slight smoke or odor during initial operation

1. Not enough air
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance, page 13) 2. Replace gas control 3. Problem will stop after a few hours of operation
2. Gas regulator defective 3. Residues from manufacturing processes and logs curing

Moisture/condensation noticed on windows

1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and Ventilation requirements (page 4)

Heater produces a whistling noise when burner is lit

1. Turning control knob to HI position when burner is cold 2. Air in gas line
1. Turn control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local natural or propane/LP gas company 3. Observe minimum installation clearances (see page 7) 4. Clean burner (see Cleaning and Maintenance, page 13) or replace burner orifice
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice

Dark residue on logs or inside of fireplace

1. Improper log placement
1. Properly locate logs (see Installing Log Set, page 11) 2. Eliminate source of drafts around heater
2. Drafts or other air currents affecting flame pattern 3. Air holes at burner inlet blocked
3. Clean out air holes at burner inlet. Periodically repeat as needed 4. Remove blockage
4. Burner flame holes blocked

White powder residue forming within burner box or on adjacent walls or furniture

1. When heated, vapors from furniture polish, wax, carpet cleaners, etc. may turn into white powder residue
1. Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Delayed ignition burner

Page 16 of the Desa Tech Cast Iron Stove (CSNPT) user manual — OBSERVED PROBLEM
Page 16 · click to enlarge
Page 16
Desa Tech Cast Iron Stove (CSNPT) — TROUBLESHOOTING Continued diagram (page 16)
Fig. 42 · TROUBLESHOOTING Continued

TROUBLESHOOTING Continued

Desa Tech Cast Iron Stove (CSNPT) — TROUBLESHOOTING Continued diagram (page 16)
Fig. 43 · TROUBLESHOOTING Continued
  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person

Heater produces unwanted odors

1. Heater burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See IMPORTANT statement above) 2. Gas leak. See Warning statement at top of page
1. Open window and ventilate room. Stop using odor causing products while heater is running
2. Locate and correct all leaks (see Checking Gas Connections , pages 9 and 10)

Heater shuts off in use (ODS operates)

1. Not enough fresh air is available 2. Low line pressure
1. Open window and/or door for ventilation 2. Contact local natural or propane/LP gas company 3. Clean ODS/pilot (see Cleaning and Maintenance, page 13)
3. ODS/pilot is partially clogged

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at top of page 2. Control valve defective
1. Locate and correct all leaks (see Checking Gas Connections , pages 9 and 10) 2. Replace control valve
1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page

Gas odor during combustion

1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections , pages 9 and 10)

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 17 of the Desa Tech Cast Iron Stove (CSNPT) user manual — INFORMATION VIDEO - 108917-01
Page 17 · click to enlarge
Page 17
Desa Tech Cast Iron Stove (CSNPT) — SPECIFICATIONS diagram (page 17)
Fig. 44

SPECIFICATIONS

SERVICE HINTS

CSBPT, CSPBPT, CSPIPT (Includes SL30PT Burner Chassis) Btu (Variable) 16,000/30,000 Type Gas Propane/LP Only Ignition Piezo Pressure Manifold 8" W.C. Inlet Gas Pressure (in. of water)

  • When Gas Pressure Is Too Low
  • pilot will not stay lit
  • burners will have delayed ignition
  • heater will not produce specified heat
  • propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.

Maximum 14" Minimum* 11" Shipping Weight 265 lbs. * For input adjustment CSBNT, CSPBNT, CSPINT (Includes SL30NT Burner Chassis) Btu (Variable) 16,000/30,000 Type Gas Natural Gas Only Ignition Piezo Pressure Manifold 3.5" W.C. Inlet Gas Pressure (in. of water)

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical service web site at www.desatech.com

ACCESSORIES

Maximum 10.5" Minimum* 5" Shipping Weight 265 lbs. * For input adjustment

Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA Heating Products at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.

REPLACEMENT PARTS

PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040.

EQUIPMENT SHUTOFF VALVE - GA5010

For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.

  • When calling DESA Heating Products, have ready
  • your name
  • your address
  • model and serial numbers of your heater
  • how heater was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date

CLEANING KIT - CCK (Not Shown)

For all models. Your vent-free gas appliance requires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.

Usually, we will ask you to return the part to the factory.

INFORMATION VIDEO - 108917-01

PARTS NOT UNDER WARRANTY

For all models. A care and maintenance video is available by calling 1-866-672-6040. You may also email your request to productsupport@desaint.com.

  • Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see page 22) or call DESA Heating Products at 1-866-672-6040 for referral information. When calling DESA Heating Products, have ready
  • model number of your heater
  • the replacement part number

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 18 of the Desa Tech Cast Iron Stove (CSNPT) user manual — MODELS SL30PT AND SL30NT
Page 18 · click to enlarge
Page 18
Desa Tech Cast Iron Stove (CSNPT) — ILLUSTRATED PARTS BREAKDOWN diagram (page 18)
Fig. 45

ILLUSTRATED PARTS BREAKDOWN

Desa Tech Cast Iron Stove (CSNPT) — ILLUSTRATED PARTS BREAKDOWN diagram (page 18)
Fig. 46

MODELS SL30PT AND SL30NT

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 19 of the Desa Tech Cast Iron Stove (CSNPT) user manual — PARTS AVAILABLE — NOT SHOWN
Page 19 · click to enlarge
Page 19
Desa Tech Cast Iron Stove (CSNPT) — ILLUSTRATED PARTS BREAKDOWN diagram (page 19)
Fig. 47

PARTS LIST

This list contains replaceable parts used in your stove. For replace- ment parts see Replacement Parts on page 17 of this manual.

KEY PART NUMBER NO. SL30PT SL30NT DESCRIPTION QTY.

1 104026-02 104026-02 Stove Log 1 2 098249-01 098249-01 Nut, M5 2 3 ** Painted Base Assembly 1 4 104454-01 104454-01 Bracket, Regulator 1 5 098867-10 098867-14 Gas Regulator 1 6 104425-01 104425-01 Inlet Tube 1 7 104422-02 104424-01 Outlet Burner Tube 1 8 099056-19 099056-26 Burner Orifice Injector 1 9 111124-01 111124-01 Burner Retainer Spring 1 10 102980-01 102980-01 Burner 1 11 101329-22 101329-21 Control Valve 1 12 104472-01 104472-01 Bracket 1 13 099211-01 099211-01 Screw 2 14 102445-01 102445-01 Piezo Ignitor 1 15 099387-13 099387-13 Pilot Tube 1 16 098271-10 098271-10 Ignitor Cable 1 17 104286-01 104285-01 ODS Pilot 1 18 M11084-38 M11084-38 Screw, Hex Head (#8-18 x .38) 7

PARTS AVAILABLE — NOT SHOWN

100563-01 100563-01 Warning Plate 1 101054-01 101054-01 Lighting Instructions Plate 1 100565-01 100565-01 Warning Plate Fastener 1 101137-04 101137-04 Hardware Kit 1

** Not a field replaceable part.

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 20 of the Desa Tech Cast Iron Stove (CSNPT) user manual — STOVE BODY MODELS CSB SERIES, CSPB SERIES, AND CSPI SERIES
Page 20 · click to enlarge
Page 20
Desa Tech Cast Iron Stove (CSNPT) — ILLUSTRATED PARTS BREAKDOWN diagram (page 20)
Fig. 48

ILLUSTRATED PARTS BREAKDOWN

Desa Tech Cast Iron Stove (CSNPT) — ILLUSTRATED PARTS BREAKDOWN diagram (page 20)
Fig. 49

STOVE BODY MODELS CSB SERIES, CSPB SERIES, AND CSPI SERIES

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 21 of the Desa Tech Cast Iron Stove (CSNPT) user manual — PARTS AVAILABLE — NOT SHOWN
Page 21 · click to enlarge
Page 21
Desa Tech Cast Iron Stove (CSNPT) — ILLUSTRATED PARTS BREAKDOWN diagram (page 21)
Fig. 50

PARTS LIST Models CSB Series, CSPB Series, and CSPI Series

PARTS LIST

This list contains replaceable parts used in your stove. For replace- ment parts see Replacement Parts on page 17 of this manual.

KEY PART NUMBER NO. CSB Series CSPB Series CSPI Series DESCRIPTION QTY. (Black) (Porcelain Black) (Porcelain Ivory)

1L 111698-01 111698-02 111698-03 Top Grate - Left 1 1C 111698-07 111698-08 111698-09 Top Grate - Center 1 1R 111698-04 111698-05 111698-06 Top Grate - Right 1 2 111698-11 111698-12 111698-13 Bottom Door 1 3 111531-01CK 111531-01CK 111531-01CK Stove Dropped Pan (Black Only) 1 4 111698-14 111698-15 111698-16 Left Stove Door 1 5 111698-17 111698-18 111698-19 Right Stove Door 1 6 111698-20 111698-21 111698-22 Stove Leg 4 7 111764-01 111764-01 111764-01 Hardware Kit 1 7-1 * * * Door Hinge Step Bolt With Shoulder (1 Per Unit) With Two M8 Washers 1 7-2 * * * Door Catch Bolt M8 x 1.25 - 55mm Long With Two M8 Hex Nuts 1 7-3 * * * Leg Attachment Bolt M10 x 1.5 - 40mm Long 4 8-1 111732-01 111732-01 111732-01 Back Panel Bolts M6 x 20mm Long 4 8-2 111733-01 111733-01 111733-01 M6 Washer 4 8-3 111733-02 111733-02 111733-02 M8 Washer 4 9 111532-01CK 111532-01CK 111532-01CK Stove Back Panel (Black Only) 1 10 111698-23 111698-23 111698-23 Door Knob 1 11 103297-04 103297-04 103297-04 Screen 1 12 111533-01 111533-01 111533-01 Screen Rod 1

PARTS AVAILABLE — NOT SHOWN

104108-08 — — Touch-up Spray Paint 12 oz Can, Black 1

* Included In Hardware Kit

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 22 of the Desa Tech Cast Iron Stove (CSNPT) user manual — PARTS CENTRALS
Page 22 · click to enlarge
Page 22
Desa Tech Cast Iron Stove (CSNPT) — ILLUSTRATED PARTS BREAKDOWN diagram (page 22)
Fig. 51

PARTS CENTRALS

These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.

Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department

Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com

Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-888-619-7060 sales@portableheaterparts.com techservice@portableheaterparts.com

East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep

Laporte’s Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 843-332-0191 Parts Department

FBD 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com

Master Parts Dist. 1251 Mound Ave NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 23 of the Desa Tech Cast Iron Stove (CSNPT) user manual — OWNER'S REGISTRATION FORM
Page 23 · click to enlarge
Page 23

OWNER'S REGISTRATION FORM

23 23 • ACCESSORIES

In order to provide better customer service for this and future purchases, we recommend that you register your product with us. You can register online at www.desatech.com. If access to our website is not available to you, please complete this Owner’s Registration Form and mail to the address on the back of this owner’s manual. Please provide the following product information:

Brand(Comfort Glow, Vanguard, etc.)
Model(EFP33PR, VTGH33NR, etc.)

Date Purchased: Note: Keep receipt for warranty verification.

Serial Number: 7 or 9 digit number located on product or identification tag.

First NameLast Name:

Address:

CityState: Zip: Country:
Home Phone( ) -

E-Mail:

Please answer the following questions to register your product with DESA Heating Products:

1. Where will the product be used?

❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other

2. If you bought this product yourself, did you plan to purchase this type of product before going into the store? ❍ Yes ❍ No
3. Who selected the product? ❍ Male ❍ Female ❍ Both
4. What is the population of your area? ❍ Under 10,000 ❍ 10,000 to 25,000 ❍ 25,000 to 50,000 ❍ 50,000 to 100,000

❍ 100,000 to 250,000 ❍ Over 250,000

5. What is your primary source of heat? ❍ Propane (LP Gas) ❍ Fuel Oil ❍ Wood ❍ Natural Gas ❍ Electric ❍ Other
6. How was the product installed? ❍ Professional Installer ❍ Self ❍ Other
7. Cost of product excluding sales tax? $
8. Cost to install product? $
9. Type of store where product was purchased? ❍ Hardware ❍ Propane Dealer ❍ Natural Gas/Utility Co. ❍ Home Center/Builder’s Supply

❍ Fireplace or Hearth Shop ❍ Farm Store ❍ Other

10. What motivated you to buy this product? ❍ Sudden Cold Weather ❍ Replace Older Model ❍ D.I.Y. Home Project

❍ Emergency Back-Up Heat ❍ Heater was on Sale ❍ Energy Savings/High Efficiency ❍ Construction Project ❍ Other

11. How did you learn about this product brand? ❍ Advertising ❍ Relative or Friend ❍ Store Display ❍ Other
12. Level of Education of Purchaser: ❍ Some High School ❍ Completed High School ❍ Completed College ❍ Completed Graduate School
13. Age of Purchaser: ❍ Under 20 ❍ 20 - 29 ❍ 30 - 39 ❍ 40 - 49 ❍ 50 - 59 ❍ 60 or Over
14. Buyer’s total annual household income: ❍ Under $15,000 ❍ $15,000 to $19,999 ❍ $20,000 to $34,999 ❍ $35,000 to $49,999

❍ $50,000 to $74,999 ❍ $75,000 to $99,999 ❍ $100,000 and Over

15. Store where product was purchased:
Name______________________________________
City_______________________ State: __________
16. In choosing this product, how important were the following:

Availability Price Brand Name Overall Quality Heat Output Made in USA Warranty Local Service Value for Price Prior Brand Experience Controls Location Thermostat, Remote, or Manual Operation Ease of Operation Special Features Salesperson’s Recommendation Friend/Relative’s Recommendation Portability Quiet Operation

Not Important Somewhat Important Very Important

❍

❍

❍

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 24 of the Desa Tech Cast Iron Stove (CSNPT) user manual — ILLUSTRATED PARTS BREAKDOWN
Page 24 · click to enlarge
Page 24
Desa Tech Cast Iron Stove (CSNPT) — ILLUSTRATED PARTS BREAKDOWN diagram (page 24)
Fig. 52

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004

Desa Tech Cast Iron Stove (CSNPT) — ILLUSTRATED PARTS BREAKDOWN diagram (page 24)
Fig. 53

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Postage Required

Page 25 of the Desa Tech Cast Iron Stove (CSNPT) user manual — NOTES
Page 25 · click to enlarge
Page 25
Desa Tech Cast Iron Stove (CSNPT) — ILLUSTRATED PARTS BREAKDOWN diagram (page 25)
Fig. 54

NOTES

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 34 more labels / short text on this page
_______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________ · _______________________________________________________________________________________________
Page 26 of the Desa Tech Cast Iron Stove (CSNPT) user manual — NOT A UPC
Page 26 · click to enlarge
Page 26
Desa Tech Cast Iron Stove (CSNPT) — ILLUSTRATED PARTS BREAKDOWN diagram (page 26)
Fig. 55
Desa Tech Cast Iron Stove (CSNPT) — ILLUSTRATED PARTS BREAKDOWN diagram (page 26)
Fig. 56

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY VENT-FREE PROPANE/LP GAS OR NATURAL GAS LOG HEATERS

AND CAST IRON STOVE CHASSIS

DESA Heating Products warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to restore this heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA Heating Products who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING PRODUCTS’ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com

111487-01 Rev. A 06/03

NOT A UPC

111487-01A For more information, visit www.desatech.com For more information, visit www.desatech.com

111487 01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Desa Tech Cast Iron Stove (CSNPT)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa Tech Cast Iron Stove (CSNPT)

Be the first to ask — other owners or our team will answer.

Original document

Desa Tech Cast Iron Stove (CSNPT) manual PDF

26 pages·2.9 MB·Stove·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…