S39NT 20,000 to 39,000 Btu/Hr Thermostatically-
Controlled
H
O
T
O
N
O
F
F
P
O
flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS
a qualified installer, service agency, or the gas supplier.
This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Save this manual for future reference. Save this manual for future reference.
Save this manual for future reference.




You must operate this heater with the heater screen in place. Make sure heater screen is in place before running heater.
Keep the appliance area clear and free from combus- tible materials, gasoline, and other flammable vapors and liquids.

Figure 1 - Vent-Free Natural Gas Stove
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com
Stove Cabinet · Screen · Logs


Safety Pilot Piezo Ignition System AIR FOR COMBUSTION AND VENTILATION
The following are excerpts from National Fuel Gas Code ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space
The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable win- dows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 6.
If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Heater Loca- tion, page 5.
Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
The National Fuel Gas Code ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.
Exhaust fans, heaters, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


AIR FOR COMBUSTION AND VENTILATION Determining Fresh-Air Flow for Heater Location
A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air From Out- doors, page 6.
Use this work sheet to determine if you have a confined or unconfined space.
C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
Length x Width x Height = cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills or open- ings, add the volume of these rooms to the total volume of the space.
(volume of space) x 20 = (Maximum Btu/Hr the space
Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)
Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws com- bustion air from the outdoors and vents to the outdoors.
Btu/Hr (maximum the space can support)
Btu/Hr (actual amount of Btu/Hr used)
69,000 Btu/Hr (actual amount of Btu/Hr used)
The space in the above example is a confined space because the actual Btu/ Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com
can support) · 30,000 39,000 69,000



Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.
Figure 3 - Ventilation Air from Outdoors
NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
Ventilation Grills Into Adjoining Room,
Or Remove Door into Adjoining
O
O
F
F
P
O
T
O
N
Figure 2 - Ventilation Air from Inside Building
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


Installation Items Needed
Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 24.
Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 4. Measure from outermost point of stove top.
Minimum Wall and Ceiling Clearances (see Figure 4) A. Clearances from outermost point of stove top to any combus- tible side wall should not be less than 12 inches. B. Clearances from outermost point of stove top to any combus- tible back wall should not be less than 6 inches (Includes cor- ner installations). C. Clearances from the stove top to the ceiling should not be less than 48 inches.
Figure 5 - Gas Regulator Location and Gas Line Access Into Stove Cabinet


Figure 4 - Minimum Clearance to Walls and Ceiling
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com



We recommend that you install a sediment trap in supply line as shown in Figure 6. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 6).

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping sys- tem. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 4. Check all joints of gas supply piping system. Apply a noncor- rosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.
CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap*
From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)

Approved Flexible Gas Hose (if allowed by local codes)
Figure 6 - Gas Connection
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 24. **Minimum inlet pressure for purpose of input adjustment.
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com
Sediment Trap


Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 7). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to equipment shutoff valve (see Figure 8). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 7). 2. Open main gas valve located on or near gas meter. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figure 8). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 13 and 14). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 14).
It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.
Place one-piece log set on grate to fit as illustrated in Figure 10. Make sure log sits flat on firebox floor (see Figure 9). IMPORTANT: Make sure log does not cover any burner ports (see Figure 10).

One Piece Log Set
Figure 7- Equipment Shutoff Valve

Figure 9 - Installing One-Piece Log Set
One Piece Log Set Burner Ports
Figure 10 - Installing One-Piece Log set (Top View)
Figure 8 - Checking Gas Joints
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


7. Remove the two blower mounting brackets from the rear panel by removing two screws each (see Figure 14). 8. Attach the two mounting brackets to blower housing using four screws provided in blower kit (2 for each bracket) (see Figure 14). Tighten screws securely. Place blower assembly tempo- rarily on top of firebox. 9. Working from the rear of the stove, place entire power cord, including speed control housing, in lower control compartment. 10. Route ends of 3-wire power cord up from the lower control com- partment through the plastic bushing, then up to the upper cavity of stove (see Figure 15, page 11). 11. Attach the terminal ends of the white and black power cord wires to the terminals on the blower motor (see Figure 12). Push firmly. 12. Attach the terminal end of the green power cord wire to the front tab of the blower housing using screw provided (see Figure 13).
1. Remove 2 screws from rear tabs on top trim. Pull trim forward to remove (see Figure 11). 2. Remove top panel of stove by removing three screws from under top lip on each side of stove (see Figure 11). 3. Facing front of stove, carefully slide top panel forward until it is completely removed from stove (see Figure 11). 4. Install one plastic bushing provided in blower kit into the 1 1/2" hole in the left rear of firebox floor. Access hole through the rectangular opening in the rear panel (see Figure 12). 5. Disconnect power cord wires from blower motor (if connected) (see Figure 13). 6. Disconnect green ground wire from blower housing (if connected) by removing screw holding wire terminal (see Figure 13).

Figure 14 - Removing Blower Brackets from Stove and Attaching to Blower
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com
White Powercord Wire


13. Using the four screws previously removed, mount blower as- sembly to stove by reattaching blower brackets to rear panel (see Figure 14, page 10). Tighten screws securely. 14. Install plastic control knob onto output shaft of speed control housing (see Figure 15). Place speed control housing just inside control compartment door in front of stove (see Figure 16). 15. Using two screws provided in blower kit, mount blower speed control housing to mounting tab in left side of lower control compartment (see Figure 16). 16. Check to make sure that the power cord is completely clear of blower wheel and there are no foreign objects in blower wheel. 17. Carefully replace stove top panel. Align holes and replace six screws removed in step 1, page 10. Slide top trim onto top panel. Attach with two screws removed in step 1, page 10. 18. Peel off the backing paper and stick the supplied wiring dia- gram decal on the stove floor as shown in Figure 15. 19. Plug power cord into a convenient 3-prong grounded wall recep- tacle near the stove. 20. Using speed control knob, turn blower on and check for operation. 21. All remaining parts from blower kit may be discarded.
Figure 16 - Installing Blower Control Housing
1. Remove 2 screws from rear tabs on top trim. Pull trim forward to remove (see Figure 11, page 10). 2. Remove three screws from under top lip on each side of stove to remove top panel (see Figure 11, page 10). 3. Facing front of stove, carefully slide top panel forward until it is completely removed from stove (see Figure 11, page 10). 4. Install one plastic bushing provided in blower kit into the 1 1/2" hole in the left rear of firebox floor. Access hole through the rectangular opening in the rear panel (see Figure 12, page 10).
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105°C wire or it’s equivalent.
On 110/115 V.A.C.
Speed Control Housing Control Knob
101584-05 120 Vac. 60 Hz. . 78 Amps DESA International, Bowling Green, KY
Figure 15 - Routing Power Cord
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


5. Disconnect power cord wires from blower motor (if connected) (see Figure 13, page 10). 6. Disconnect green ground wire from blower housing (if con- nected) by removing screw holding wire terminal (see Figure 13, page 10). 7. Remove the two blower mounting brackets from the rear panel by removing two screws each (see Figure 14, page 10). 8. Attach the two mounting brackets to blower housing using four screws provided in blower kit (2 for each bracket) (see Figure 14, page 10). Tighten screws securely. Place blower assembly temporarily on top of firebox. 9. If screen is installed, carefully lift slightly and pull forward to remove. 10. If logs are installed, carefully remove and set aside. 11. Remove three screws and cover plate from center of firebox back panel. Keep screws but discard cover plate (see Figure 17). 12. Locate thermostatic switch/cover plate assembly and wire har- ness supplied with blower. Attach wire harness terminals to terminals on thermostatic switch. Push firmly. Make sure the bottom hole of cover is on the opposite side from the wire harness (see Figure 18). 13. Feed terminal ends of wire harness into the hole in firebox back panel from front of firebox. Pull the ends of the harness to the top of firebox near blower (see Figure 19). 14. Align holes in the switch/cover assembly with holes in firebox back panel. Using 3 screws from step 11, attach assembly to firebox back panel. Tighten screws firmly (see Figure 19).
Thermostatic Switch Mounted to Cover
Hole in Firebox Back Panel
Figure 19 - Assembling Thermostatic Switch and Cover to Firebox Back Panel

Black Speed Control Wire
White Speed Control Wire
If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105°C wire or it’s equivalent.
Variable Fan Switch Fan Switch
110/115 V.A.C.
120 Vac. 60 Hz. 90 Amps
DESA International, Bowling Green, KY
Speed Control Housing Control Knob
Figure 18 - Attaching Wire Harness to Thermostatic Switch and Cover Assembly
Figure 20 - Connecting Switch, Blower, and Speed Control Wires
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


INSTALLATION Continued

18. Connect the black wire from speed control to blue wire on switch/cover assembly (see Figure 20, page 12). 19. Connect red wire from switch/cover assembly to remaining terminal on blower motor (see Figure 20, page 12). Push firmly. 20. Attach green wire from speed control to front tab of blower housing using screw provided (see Figure 20, page 12). Tighten securely. 21. Using the four screws previously removed, mount blower as- sembly to stove by reattaching blower brackets to rear panel (see Figure 14, page 10). Tighten screws securely. 22. Install plastic control knob onto output shaft of speed control housing (see Figure 20, page 12). Place speed control hous- ing just inside control compartment door in front of stove (see Figure 16, page 11). 23. Using two screws provided in blower kit, mount blower speed control housing to mounting tab in left side of lower control compartment (see Figure 16, page 11). 24. Check to make sure that the power cord is completely clear of blower wheel and there are no foreign objects in blower wheel. 25. Carefully replace stove top panel. Align holes and replace six screws removed in step 1, page 11. Slide top trim over sides of top panel. Attach with 2 screws removed in step 1, page 11. 26. Peel off the backing paper and stick the supplied wiring dia- gram decal on the stove floor as shown in Figure 20, page 12. 27. Plug power cord into a convenient 3-prong grounded wall recep- tacle near the stove.


1. STOP! Read the safety information, above. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise Clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, above. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise C-clockwise to the PILOT position. Press in control knob for five (5) seconds (see Fig- ure 21, page 14). Note: You may be running this heater for the first time after hooking up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


Lighting Instructions (Cont.) To Turn Off Gas to Appliance Thermostat Control Operation Manual Lighting Procedure Operating Optional Blower Accessory
6. With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for sys- tem to reset before lighting pilot again. 8. Turn control knob counterclockwise C-clockwise to desired heat- ing level. The burners should light. Set control knob to any heat level between HI and LO.
OPERATION
The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.
PROCEDURE
Control Knob Ignitor Button
BLOWER ACCESSORY Figure 21 - Control Knob and Ignitor Button Location
Light your gas appliance with the blower off. Turn the blower on to deliver heated air at the top louvers. The blower features a variable control which allows you to select the speed you desire.
If using the GA3650TA Blower Accessory: In the ON position, the blower will start when the thermostat senses a sufficient increase in firebox temperature (approximately 10 to 20 min- utes depending on heat setting). Note: Your gas stove and thermostat blower will not turn on and off at the same time. The stove may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
Figure 22 - Pilot

Shutting Off Heater Turn control knob clockwise Clockwise to the OFF position. Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise Clockwise to the PILOT position.
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com
Ignitor Electrode · Thermocouple Pilot Burner


pilot Flame Pattern Burner Flame Pattern CLEANING AND MAINTENANCE Cleaning Burner Injector Holder and Pilot Air Inlet Hole
CLEANING AND MAINTENANCE
Check pilot flame pattern and burner flame patterns often.

Figure 23 shows a correct pilot flame pattern. Figure 24 shows an incorrect pilot flame pattern. (Note: Appearance of pilot assembly may vary by model). The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
Thermocouple Pilot Burner Pilot Burner Thermocouple
The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt,lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.
Figure 23 - Correct Pilot Flame Pattern
Figure 24 - Incorrect Pilot Flame Pattern
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 27). 3. Blow air through the ports/slots and holes in the burner. 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.
Approx. 3-6" Above Top of Logs
Figure 25 - Correct Flame Pattern with Control Knob Set to High Flame

Figure 26 - Incorrect Flame Pattern with Control Knob Set to High Flame
Figure 27 - Injector Holder On Outlet Burner Tube
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


SPECIFICATIONS
Btu (Variable) 20,000/39,000 Type Gas Natural Only Ignition Piezo Manifold Pressure 3.5" W.C. Inlet Gas Pressure (in. of water) *
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 28). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Maximum 10.5" Minimum 5" Dimensions, Inches (H x W x D)

Stove 31 x 32 x 19 1/4 Carton 24 x 31 1/2 x 35 1/4 Weight, pounds
Stove 78 lbs. Shipping 95 lbs.
* For purposes of input adjustment
Figure 28 - Pilot Inlet Air Hole
You may feel your gas pressure is too low. If so, contact your local natural gas supplier.
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Ser- vice Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.
You can also visit DESA International’s technical services web site at www.desatech.com
Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com
Ports/Slots · Burner Tube


TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
POSSIBLE CAUSE
REMEDY
When ignitor button is pressed, there is no spark at ODS/pilot
When ignitor button is pressed, there is spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when control knob is released
B) Clean ODS/pilot (see Cleaning and Maintenance, pages 15 and 16) or re- place ODS/pilot assembly
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


REMEDY
Burner does not light after ODS/pilot is lit
Burner backfiring during combustion
Slight smoke or odor during initial operation
Moisture/condensation noticed on windows
Heater produces a whistling noise when burner is lit
Dark residue on logs or inside of stove
White powder residue forming within burner box or on adjacent walls or furniture
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com
Delayed ignition burner



POSSIBLE CAUSE
REMEDY
Heater produces a clicking/ticking noise just after burner is lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
Burner flame is excessively large and is very near or touches the top of firebox
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


S39NT This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.

1 107433-02 Log Set 1 2 104285-01 ODS Pilot (NG) 1 3 098249-01 ODS Nut 2 4 107090-01 Burner Outlet Tube 1 5 107089-01 Inlet Tube 1 6 102843-01 Burner Clip 1 7 099056-16 Burner Orifice Injector 1 8 101329-20 Gas Control Valve 1 9 102772-01 Burner 1 10 099387-09 Pilot Tube 1 11 098271-10 Ignitor Cable 1 12 101381-01 Piezo Ignitor and Cover 1 13 105990-01 Pilot Shield 1 14 098867-09 Regulator 1
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.
KEY NO. PART NO. DESCRIPTION QTY.
1 107085-01CK Top Panel, Stove 1 2 ** Pedestal Stove Assembly 1 3 107076-01CK Stove Base 1 4 ** Stove Back Panel 1 5 107082-01CK Top Trim 1 6 105657-01 Blower Bracket 2 7 107363-01CK Door 1 8 107078-01CJ Firebox Back Panel 1 9 107080-01CK Firebox Floor 1 10 107081-01CJ Firebox Top 1 11 107365-01CK Screen Assembly 1 12 101382-01 Valve Bracket 1 13 107092-01 Brass Trim, Bottom 1 14 107093-01 Brass Trim, Firebox 1 15 106754-01 Knob 1 16 101386-02 Door Hinge 2 17 099230-02 Shoulder Screw 4 18 107079-01CJ Heat Deflector 1 19 102455-12 Louver, Small 2 20 102455-13 Louver, Large 1 21 107091-01CK Support, End Louver 2 22 107084-01CK Support, Center Louver 2 23 101514-01 Blower Sensor Cover 1 24 103158-01 Magnet Catch 1 25 107083-01 Magnet Bracket 1 26 098304-03 Louver Screw 12
101054-01 Lighting Instructions Plate 1 100563-01 Warning Plate 1 104108-06 Touch-Up Paint Kit 1
** Part not available for field replacement.
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


ACCESSORIES
Purchase these heater accessories from your local dealer or Parts Central (see page 25). If they cannot supply these accessories call DESA International’s Sales Department at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.
Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA International’s Technical Service Department at 1-866-672-6040 for referral information.
Equipment shutoff valve with 1/8" NPT tap.
Usually, we will ask you to return the part to the factory.
Contact authorized dealers of this product or Parts Central (see page 25). If they can’t supply original replacement part(s) call DESA International at 1-866-672-6040 for referral information.
Provides better heat distribution. Features variable speed control knob.
Provides better heat distribution. Features variable speed control knob.
Your vent-free gas appliance requires regular cleaning and mainte- nance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.
A care and maintenance video is available by calling 1-866-672-6040.
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com

25 25 • ACCESSORIES
In order to provide better customer service for this and future purchases, we recommend that you register your product with us. You can register online at www.desatech.com. If access to our website is not available to you, please complete this Owner’s Registration Form and mail to the address on the back of this owner’s manual. Please provide the following product information:
Date Purchased: Note: Keep receipt for warranty verification.
Serial Number: 7 or 9 digit number located on product or identification tag.
Address:
E-Mail:
Please answer the following questions to register your product with DESA International:
❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other
❍ 100,000 to 250,000 ❍ Over 250,000
❍ Fireplace or Hearth Shop ❍ Farm Store ❍ Other
❍ Emergency Back-Up Heat ❍ Heater was on Sale ❍ Energy Savings/High Efficiency ❍ Construction Project ❍ Other
❍ $50,000 to $74,999 ❍ $75,000 to $99,999 ❍ $100,000 and Over
Not Important Somewhat Important Very Important
Thermostat, Remote, or Manual Operation
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com


2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004

107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com
Postage Required


These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.
Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department
East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep
Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-888-619-7060 sales@portableheaterparts.com techservice@portableheaterparts.com
Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404-0275 All States 937-258-3721 OH 1-800-762-3426
Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382-4500 610-430-7717 1-800-368-0803 www.halcoenterprises.com
FBD 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com
Laporte’s Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 843-332-0191 Parts Department
Master Parts Dist. 1251 Mound Ave NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com
Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com
Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com



Always specify model and serial numbers when communicating with the factory.
We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com
107434-01 Rev. C 05/02
107434-01C For more information, visit www.desatech.com For more information, visit www.desatech.com
107434 01
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.