PELLET STOVE
EF3
Freestanding, Fireplace Insert,
and Built-In Heater
OWNER’S MANUAL



installation inspection requirements in your area.
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY,
OR EVEN DEATH.



Pellet quality is important, please read the following:
Your enviro pellet stove has been designed to burn wood pellets only. Do not use any other type of fuel, as this will void any warranties stated in this manual.
The performance of your pellet stove is greatly affected by the type and quality of wood pellets being burned. As the heat output of various quality wood pellets differs, so will the performance and heat output of the pellet stove. CAUTION: It is important to select and use only pellets that are dry and free of dirt or any impurities such as high salt content. Dirty fuel will adversely affect the operation and performance of the unit and will void the warranty. The Pellet Fuel Industries (P.F.I.) has established standards for wood pellet manufacturers. We recommend the use of pellets that meet or exceed these standards. Ask your dealer for a recommended pellet type. P.F.I. PELLET STANDARDS:
Fines (fine particles) 1% maximum through a 1/8” screen Bulk Density 40 pound per cubic foot minimum Size 1⁄4” to 5/16” diameter 1⁄2 – 11⁄2” long maximum Ash Content 1% maximum (Premium grade) 3% maximum (Standard grade) Moisture Content 8% maximum Heat Content approximately 8200 Btu per pound minimum
ASH: The ash content of the fuel and operation of your stove will directly determine the frequency of cleaning. The use of high ash fuels may result in the stove needing to be cleaned daily. A low ash fuel may allow longer intervals between cleaning. CLINKERING: [clinkers are silica (sand) or other impurities in the fuel that will form a hard mass during the burning process]. This hard mass will block the air flow through the Burn Pot Liner and affect the performance of the stove. Any fuel, even approved types, may tend to clinker. Check the Burn-Pot Liner daily to ensure that the holes are not blocked with clinkers. If they become blocked, remove the liner (when the unit is cold) and clean/scrape the clinkers out. Clean the holes with a small pointed object if required. Refer to the section Routine Cleaning and Maintenance. PELLET FEED RATES: Due to different fuel densities and sizes, pellet feed rates may vary. This may require an adjustment to the slider damper setting or to the auger feed trim setting on low.
Since Sherwood Industries Ltd. has no control over the quality of pellets that you use, we assume no liability for your choice in wood pellets.
Store pellets at least 36” (1 m) away from the pellet stove.
Freestanding: The rating label is located on the inside of the hopper lid. Insert: The rating label is located on the hopper cover.

Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death. Contact your local building or fire official to obtain a permit and any information on installation restrictions and inspection requirements for your area.
To prevent the possibility of a fire, ensure that the appliance is properly installed by adhering to the installation instructions. An ENVIRO dealer will be happy to assist you in obtaining information with regards to your local building codes and installation restrictions.
Be sure to maintain the structural integrity of the home when passing a vent through walls, ceilings, or roofs.
The stove’s exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure. It is very important to ensure that the exhaust system be sealed and airtight. The ash pan and viewing door must be locked securely for proper and safe operation of the pellet stove.
Do not burn with insufficient combustion air. A periodic check is recommended to ensure proper combustion air is admitted to the combustion chamber. Setting the proper combustion air is achieved by adjusting the slider damper located on the left side of the stove.
When installing the stove in a mobile home, it must be electrically grounded to the steel chassis of the home and bolted to the floor. Make sure that the structural integrity of the home is maintained and all construction meets local building codes.
Minor soot or creosote may accumulate when the stove is operated under incorrect conditions such as an extremely rich burn (black tipped, lazy orange flames).
If you have any questions with regard to your stove or the above-mentioned information, please feel free to contact your local dealer for further clarification and comments.
Do not burn garbage or flammable fluids such as gasoline, naptha or engine oil. Unit hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns.
FUEL: This pellet stove is designed and approved to only burn wood pellet fuel with up to 3% ash content. Dirty fuel will adversely affect the operation and performance of the unit and may void the warranty. Check with your dealer for fuel recommendations.
THE USE OF CORDWOOD IS PROHIBITED BY LAW.
SOOT: Operation of the stove with insufficient combustion air will result in the formation of soot which will collect on the glass, the heat exchanger, the exhaust vent system, and may stain the outside of the house. This is a dangerous situation and is inefficient. Frequently check your stove and adjust the slider/ damper as needed to ensure proper combustion. See: “SLIDER/DAMPER SETTING”.
CLEANING: There will be some build up of fly ash and small amounts of creosote in the exhaust. This will vary due to the ash content of the fuel used and the operation of the stove. It is advisable to inspect and clean the exhaust vent semi-annually or every two tons of pellets.

ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be on a non-combustible floor on the ground, well away from all combustible materials pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be retained in the closed container until all cinders have been thoroughly cooled.
ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical cord should be connected to a standard 115 volts (4.5 Amps), 60 hertz electrical outlet. Be careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges and also must be accessible. If this power cord should become damaged, a replacement power cord must be purchased from the manufacture or a qualified ENVIRO dealer. The EF3’s maximum power requirement is 520 watts.
GLASS: Do not abuse the glass by striking or slamming the door. Do not attempt to operate the stove with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an ENVIRO dealer. Do not attempt to open the door and clean the glass while the unit is in operation or if glass is hot. To clean the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner, or take a damp paper towel and dip into the fly ash. This is a very mild abrasive and will not damage the glass.
FLAMMABLE LIQUIDS: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in the heater. Keep all such liquids well away from the heater while it is in use.
SMOKE DETECTOR: Smoke detectors should be installed and maintained in the structure when installing and operating a pellet burning appliance.
OPERATION: The ash pan and door must be closed securely for proper and safe operation of the pellet stove. Also ensure all gaskets on the door are checked and replaced when necessary.
KEEP ASH PAN FREE OF RAW FUEL. DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN. A fire in the ash pan may occur.
INSTALLATION: Be sure to maintain the structural integrity of your home when passing a vent through walls, ceilings, or roofs. It is recommended that the unit be secured into its position in order to avoid any displacement. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
FRESH AIR: Outside Fresh Air connection is optional. Must be connected to all units installed in Mobile and “Air Tight Homes” (R2000) or where required by local codes. Consider all large air moving devices when installing your unit and provide room air accordingly. Limited air for combustion may result in poor performance, smoking and other side effects of poor combustion.
If you have any questions with regards to your stove or the above-mentioned information, please feel free to contact your local dealer for further clarification and comments.
SINCE SHERWOOD INDUSTRIES LTD. HAS NO CONTROL OVER THE INSTALLATION OF YOUR STOVE, SHERWOOD INDUSTRIES LTD. GRANTS NO WARRANTY IMPLIED OR STATED FOR THE INSTALLATION OR MAINTENANCE OF YOUR STOVE. THEREFORE, SHERWOOD INDUSTRIES LTD. ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).

Your pellet Stove has the following safety features:
A. The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F
(49°C).
B. The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F
(93°C), the auger will automatically stop and the stove will shut down when the exhaust temperature cools. If this happens, call your local dealer to reset the 200°F (93°C) high limit switch. ALSO FIND THE REASONS WHY THE UNIT OVERHEATED.
C. The unit has a convection fan control over-ride. This function causes the convection fan to reach its full
speed when the temperature at the back of the firebox reaches 160°F (71°C). This is a normal safety feature of your unit. To compensate for the fan cycling action that may occur, turn up the blower control proportionately to the heat output.
D. If the power goes out, the unit will stop running. When the power comes back on, the stove will not
restart unless the exhaust temperature is still above 120°F (49 °C).
The slider/damper must be set at time of installation. This is used to regulate the airflow through the pellet stove. The slider damper is located behind the left side panel. To open the left side panel, undo
the one screw located in the upper front corner of the cabinet side


Figure 1: Efficient Flame.
Pellet quality is a major factor in how the Pellet stove will operate. If the pellets have a high moisture content or ash content the fire will be less efficient and has a higher possibility of the fire building up and creating clinkers (hard ash build-up).
If the fire should happen to go out and the Dial-A-Fire has been set on the lowest setting, the Slider Damper should be pushed in slightly, decreasing the air in the firebox or the Dial-A-Fire and Auger Trim can be turned up slightly.
If, after long periods of burning, the fire builds up and overflows the burn pot or there is a build up of clinkers, this would be a sign that the pellet quality is poor, this requires more primary air, the slider damper must be pulled out to compensate. Pulling the slider damper out gives the fire more air.
Figure 2: Slider / damper positions.


KNOB “A”: Fan Controller. By adjusting the knob you will vary the rate of airflow into the room by varying the speed of the convection blower. When you first start the stove, it should be placed in the “OFF” position in order to heat the unit as quickly as possible. Once the room has come up to temperature, the control may be set to a comfortable level. *Note: The convection blower may cycle to high automatically depending on the setting of knobs “A” and “B”. This is a normal safety feature of the unit.
Figure 3: Dial-A-Fire control panel.
SPECIAL NOTES: The flashing green light corresponds to the auger feed rate.
KNOB “B”: Dial a Fire Heat Output Knob. This knob controls the amount of heat output. The dial has a scale with the blue zone representing the coolest setting of the stove, and the red zone representing the hottest setting. The scale on knob “B” represents a range, not exact at times or fuel quantities. Wood pellets of differing quality may affect the performance of the stove. If the stove has trouble operating at either end of its range, turn the heat output knob back slightly.
To turn your stove off, simply turn the HEAT OUTPUT knob (“Knob B”) counter-clockwise until the knob clicks to the “OFF” position. This will stop the feed of pellets. The blowers will continue to run and cool the stove. When cool enough, the stove will shut down. DO NOT unplug unit while combustion fan is operating. This may lead to smoke escaping from the stove.

The following should be inspected periodically to ensure that the appliance is operating at its optimum and giving you excellent heat value:
The following list of components should be inspected and maintained routinely to ensure that the appliance is operating at its optimum and giving you excellent heat value:
BURN POT AND LINER (2-3 days)
This is the ‘pot’ where the pellets are burned. The burn pot and liner should be inspected every two to three days, to ensure proper air flow through the liner. Failure to keep the liner clean may cause a build up of fuel past the burn pot liner and up the drop tube. This will cause the auger to jam and may result in pellets burning in the drop tube and hopper.
Ensure the unit is cold before cleaning. To remove the burn pot and burn pot liner, open the door using the door handle provided, located on the left-hand side of the stove. Swing the door open. Lift the liner from the burn pot. Lift the burn pot from the firebox by gently lifting the front of the burn pot up first, then sliding the assembly from the air intake tube and the ignitor cartridge. Using a metal scraper, remove material that has accumulated or is clogging the liner’s holes. Then dispose of the scrapped ashes from the liner and from inside the burn pot. Place the burn pot back into the stove, making sure that the pipes are properly inserted into the burn pot and the front tabs are placed in the firebox. Place the liner back into the burn-pot making sure that the ignitor hole in the liner is aligned with the ignitor tube. Push the liner up against the ignitor tube.
Figure 4: Burn pot with liner.
INSIDE FIREBOX (weekly) For bi-weekly clean out, ash may be removed from behind the steel plates by rotating the circular cover to allow vacuuming behind the plates.
ASH PAN AND DOOR GASKETS (weekly)
After extended use the gasket may come loose. To repair or replace this, glue the gasket on, using high- temperature fiberglass gasket glue available from your local ENVIRO dealer. This is important to maintain an airtight assembly.

ASH PAN (2-3 days)
Monitor the ash level every week. Remember that different pellet fuels will have different ash contents. Ash content is a good indication of fuel efficiency and quality. Refer to “Warnings and Recommendations” for disposal of ashes. DO NOT PLACE UNBURNED OR RAW PELLET FUEL IN ASH PAN.
Dump the ashes into a metal container stored away from combustibles. Monitor the ash level every week. Remember that different pellet fuels will have different ash contents. Ash content is a good indication of fuel efficiency and quality. Refer to “Warnings and Recommendations” for disposal of ashes.
Vacuum the ash pan and inside the pedestal. CAUTION: BECAUSE THE FLY ASH IS VERY FINE, THE USE OF A FINE FILTER VACUUM BAG WILL BE REQUIRED TO PREVENT ASH FROM BEING BLOWN BACK INTO THE ROOM. Please pay special attention that there are no hot ashes in the firebox or there could be a possibility of a fire hazard inside the vacuum cleaner. Place all hot ashes into a non-combustible container.
The EF3 pellet stove freestanding’s ash pan is located under the burner, in the pedestal, and has a latching mechanism to secure it. To remove the ash pan, unlock the latch on the ash pan and then pull the pan out.
The EF3 pellet stove insert’s ash pan is located behind the lower grill.

HEAT EXCHANGER TUBES (2-3 days)
The handle for the heat exchanger cleaning rod is pointed out in Figure 5. This handle is to be pulled back and forth a few times (ONLY WHEN THE UNIT IS COLD) in order to clean away any fly ash that may have collected on the heat exchanger tubes. As different types of pellets produce different amounts of ash, cleaning of the tubes should be done on a regular basis to enable the unit to run efficiently.
FRESH AIR INTAKE (season)
Inspect periodically to be sure that it is not clogged with any foreign materials.
Figure 5: EF3 Heat exchanger rod.
For bi-weekly clean out, ash may be removed from behind the steel plates by rotating the circular covers located behind the right and left side panels. Loosen the screw on the disks and open, this will allow vacuuming behind the firebox liner’s plates.
Removal of the firebox backing for bi-annual cleaning:
EXHAUST PASSAGES (season)

Installation of firebox backing:
EXHAUST VENT (season) The products of combustion will contain small particles of flyash. The flyash will collect in the exhaust venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system. The exhaust venting system should be inspected at least once every year or after two tons of pellets to determine if cleaning is necessary. We recommend contacting your dealer for professional cleaning. To remove dust from the vent pipe, tap lightly on the pipe to dislodge any loose ash. Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of the vent pipe as possible.
Unplug the stove then open the right/left side panels to access the two blowers. Vacuum all dust from motors. Only the convection blower motor (on the right side of the stove) will require lubrication. The convection motor has two lubrication holes on it. Use two drops of SAE 20 light oil to lubricate every six months. Excess oil may damage the motor. The exhaust blower’s motor has sealed bearings, DO NOT lubricate this motor.
DOOR GLASS (It is recommended that your dealer replace the glass if broken.)
The door glass is made of 5 mm thick, high temperature PYROCERAMIC. To replace the glass, unscrew and remove the four glass retainers. Remove the glass and any broken pieces. High temperature fiberglass tape should be used around the glass. Replace the glass, center the glass assembly in the frame, then screw the glass retainers back to the frame. The use of substitute materials is prohibited use only part EF-062.
Once you are finished using the pellet appliance for the season, unplug the stove for added electrical protection. It is very important that the stove be cleaned and serviced as stated above.
Please clean all fingerprints off of all gold parts, with denatured alcohol on a soft cloth, before firing the unit each time. Fingerprints, etc. can become permanently etched into the gold if not removed before operating the pellet heater.
BRICK PANEL The paint on the steel brick panel may peel. This is due to extreme conditions applied to the paint and is in no way covered by warranty.
BLOWER MECHANISMS (season)

DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE:

To remove your new stove from its pallet, open the left and right side panels. To open the side panels remove the ash pan cover from the magnets located below the door. Remove the two (2) T-20 screws located at the bottom corners of the left and right side panels. Remove the two (2) T-20 screws located between the hopper side rails and the side panels at the front edge of the side panel. There are two (2) wood screws that are holding the bottom of the stove to the pallet. Remove the screws. Close the side panels. See “PEDESTAL INSTALLATION” to install the pedestal.

Figure 6: Screws to take out to remove stove from pallet.


Figure 7: Dimensions of EF3 Freestanding.
DIMENSIONS - FIREPLACE INSERT AND BUILT-IN HEATER:

Figure 8: Dimensions of EF3 Fireplace Insert.

When installing this unit on a combustible floor (for example linoleum, hardwood flooring) a non- combustible hearth pad must be under the unit. The pad must extend at least the width of the appliance [22” (558 mm)] and at least the depth of the appliance plus 6” (153 mm) in front of the appliance [29 3⁄4” (756 mm)].
These dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing, routine cleaning and maintenance.
Side wall to unit - 6 inches (15 cm) Back wall to unit - 1 inches (2.5 cm) Corner to unit - 1 inches (2.5 cm) Door front to edge of floor protection - 6 inches (15 cm)

Minimum Alcove width - 36 inches (91 cm) Minimum Alcove height - 48 inches (122 cm) Maximum Alcove depth - 30 inches (76 cm) Figure 10: EF3 Freestanding Minimum Alcove Size.
Side wall to unit - 8 inches (20.3 cm)
Mantel to top of unit - 8 inches (20.3 cm)
Top facing to unit - 8 inches (20.3 cm)
Side facing to unit - 6 inches (15.2 cm)
Floor protection - 6 inches (15.2 cm) on either side and to the front must be protected by non-combustible material.
Floor Protection; Minimum 6" (15 cm) in front of door
Figure 11: EF3 Fireplace Insert Clearance to Combustibles.

CLEARANCES TO COMBUSTIBLES - BUILT-IN HEATER:
Refer to Figures 11 and 12.

Side wall to unit - 8 inches (20.3 cm) Mantel projection - 10 inches (25.4 cm) Mantel to top of unit - 8 inches (20.3 cm) Top facing to unit - 8 inches (20.3 cm) Side facing to unit - 6 inches (15.2 cm) Floor protection - 6 inches (15.2 cm) (on either side and to the front must be protected by non-combustible material) Sides and rear walls to standoffs: - 0 inches (0 cm) Recess depth: - 11 inches (30 cm)


Figure 14: Fireplace Insert Pedestal.

Figure 13: Freestanding Pedestal.
Figure 15: Built-In Heater Pedestal.

IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER.
Table 1: Use in conjunction with Figure 16 for allowable exterior vent termination locations.
Letter Minimum Clearance Description
A 24 in (61 cm) Above grass, top of plants, wood, or any other combustible materials.
B 48 in (122 cm) From beside/below any door or window that may be opened.
C 24 in (61 cm) From above any door or window that may be opened.
D 24 in (61 cm) To any adjacent building, fences and protruding parts of the structure.
E 24 in (61 cm) Below any eave or roof overhang
F 12 in (30 cm) To outside corner.
G 12 in (30 cm) To inside corner, combustible wall (vertical and horizontal terminations).
H 3 ft (91 cm) within a height of 15 ft (4.5 m) above the meter/regulator assembly
To each side of center line extended above natural gas or propane meter/regulator assembly or mechanical vent.
I 3 ft (91 cm) From any forced air intake of other appliance
J 12 in (30 cm) Clearance to non-mechanical air supply inlet to building, or the combustion air inlet to any appliance.
K 24 in (61 cm) Clearance above roof line for vertical terminations.
L 7 ft (2.13 m) Clearance above paved sidewalk or paved driveway located on public property.
K
E
B
G
D F
G
B
A I
H
Air Supply Inlet Gas Meter Restriction Zone (Termination not allowed)
Figure 16: Use in conjunction with Table 1 for allowable exterior vent termination locations.
become hot enough to cause burns if touched by children. Non-combustible shielding or guards may be required.
3. Termination must exhaust above the inlet elevation. It is recommended that at least five feet of vertical pipe be installed outside when the appliance is vented directly through a wall, to create some natural draft to prevent the possibility of smoke or odor during appliance shut down or power failure. This will keep exhaust from causing a nuisance or hazard from exposing people or shrubs to high temperatures. In any case, the safest and preferred venting method is to extend the vent through the roof vertically.


Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes.
When connecting to an outside fresh air source, do not use plastic or combustible pipe. A 15⁄8” minimum (42 mm) ID (inside diameter) steel, aluminum or copper pipe should be used. It is recommended, when you are installing a fresh air system, to keep the number of bends in the pipe to a minimum.
Figure 17: Outside Air Connection.
EXHAUST AND FRESH AIR INTAKE LOCATIONS:
EXHAUST Freestanding Fireplace Insert Built-In Heater Base of unit to center of flue 16 3⁄8” (41.5 cm) 9” (22.8 cm) 10 3⁄4” (27.3 cm) Side of unit to center of flue 5 3/16” (13.2 cm) 5 3/16” (13.2 cm) 5 3/16” (13.2 cm) Center of unit to center of flue 5 3⁄4” (14.6 cm) 5 3⁄4” (14.6 cm) 5 3⁄4” (14.6 cm) FRESH AIR INTAKE. Base of unit to center of intake 10 3⁄4” (27.3 cm) 3 3⁄8” (7.4 cm) 5 1⁄8” (8.6 cm) Side of unit to center of intake 12” (30.4 cm) 12” (30.4 cm) 12” (30.4 cm) Center of unit to center of intake 1” (2.5 cm) 1” (2.5 cm) 1” (2.5 cm)

Figure 19: EF3 Fireplace Insert Inlet and Outlet Location.
Location.


Figure 20: Mobile home installation.
AND CEILING/ROOF MUST BE MAINTAINED.

Figure 21: Corner Installation.

HORIZONTAL EXHAUST THROUGH WALL INSTALLATION - FREESTANDING:
Vent installation: install vent at clearances specified by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor, or ceiling. Where passage through a wall or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365 Installation Code for Solid-Fuel-Burning Appliances and Equipment. Only use venting of L or PL type with an inside diameter of 3 or 4 inches (7.6 or 10.1 cm).
3. Place the appliance 15” (37.5 cm) away from the wall. If the stove is to be set on a hearth pad, set the unit on it. 4. Locate the center of the exhaust pipe on the stove. Extend that line to the wall. Once you have located the center point on the wall, refer to pellet vent manufacturer installation instructions for correct hole size and clearance to combustibles. 5. Install the wall thimble as per the instructions written on the thimble. Maintain an effective vapour barrier in accordance with local building codes. 6. Install a length of 3” (76 mm) or 4” (101 mm) vent pipe into the wall thimble. The pipe should install easily into the thimble. 7. Install the fresh air intake (see OUTSIDE FRESH AIR CONNECTION). 8. Connect the exhaust vent pipe to the exhaust pipe on the stove. Seal the connection with high temperature silicone. 9. Push the stove straight back, leaving a minimum of 1” (2.5 cm) clearance from the back of the stove to the wall. Seal the vent pipe to the thimble with high temperature silicone.

Figure 22: Straight through wall Installation.

3" (75mm) or 4" (100mm) "PL" or "L" vent
Silicone Required Figure 23: Venting to use with straight through wall Installation.

THROUGH WALL WITH VERTICAL RISE AND HORIZONTAL TERMINATION INSTALLATION - FREESTANDING:
A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood). Figure 24 is the recommended installation set up. Figure 25 is the installation to use if there is a concrete or retaining wall in line with exhaust vent on a pellet stove. The termination must be 12” (30 cm) from the outside wall and 12” (30 cm) above the ground.

Figure 24: Venting horizontally with rise. Figure 25: Venting with concrete wall behind unit .


Figure 26: Inside Vertical Installation.
To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “INSIDE VERTICAL INSTALLATIONS - FREESTANDING” section and then finish it by performing the following (refer to Figure 27).


Refer to Figures 28 and 29. 1. Install the hearth pad. 2. Lock fireplace damper in the open position. 3. Install a positive flue connector at the fireplace dampers. 4. Connect a tee or a 90° elbow to the exhaust pipe. 5. Install flexible stainless steel liner or listed pellet vent to the top of the chimney.
$ %* # !%!$+$ $ (&$ *&' & )*&,
!$% . ) #( . -!)* ( )
!( !%*" % *" % * (&+ " & !( '# &( * (&+ ) +$'
Figure 28: Freestanding hearth mount installation.


! $ ! % # !
% # ! ! " ! # ! !
Figure 29: Freestanding hearth mount installation overview.
The fireplace insert model requires a surround panel and a pedestal. When installing this unit, ensure that the pedestal is removed from the inside of the hopper and installed on the bottom of the unit (see “PEDESTAL INSTALLATION”).
Assemble surround panel (see “ASSEMBLING THE SURROUND PANEL - FIREPLACE INSERT”) before starting installation.
A non-combustible hearth pad must cover combustible flooring underneath, as well as 6” (150 mm) in front of the heater and 6” (150 mm) to the side of the heater.


* #% ' " && ' "%
"' " !(! ! %#! '#$ # &'#)
' " ' %#( # %$ #%
#!(&' ##% "%+ %$
Figure 30: Masonry fireplace installation.
When installing the insert into a masonry fireplace, DO NOT remove any bricks or masonry, with the following exception: masonry or steel, including the damper plate, may be removed from the smoke shelf and adjacent damper frame, if necessary, to accommodate a chimney liner. Do this only if their removal will not weaken the structure of the fireplace and chimney, and will not reduce protection for combustible materials to less than that required by the national building code. When installing the fireplace insert into a zero clearance fireplace, DO NOT cut or modify any factory firebox parts. If the fireplace insert does not fit into a zero clearance fireplace, we recommend you use an ENVIRO freestanding model and install as a hearth mounted unit. Install a 3” (76 mm) flex pipe from the stove to the top of the chimney (see “HEARTH MOUNT INSTALLATION - FREESTANDING:”).


This unit includes a 3” (75 mm) pedestal and surrounding faceplates. The part of the unit behind the faceplate can be enclosed with combustible material. It has 1” (25 mm) standoffs to establish clearances to combustibles to the back, top and sides.
Refer to “CLEARANCES TO COMBUSTIBLES - BUILT-IN HEATER“ and Figure 11 and 12 for the size and placement of the alcove to be built for the unit.
For the venting refer to “HORIZONTAL EXHAUST THROUGH WALL INSTALLATION - FREESTANDING“.
Figure 31: Built-in heater installation.
INSTALLATION OF CONTROL PANEL INTO SURROUND PANEL - FPI AND BIH:
When installing the control panel into the surround panel, the surround does not need to be assembled. The control board will be found in behind the firebox.
Place the control panel on the backside of the right surround panel so the hinge is on the outside and the top and bottom holes on the control panel line up with those on the surround. Attach using two (2) T-20 screws through the front of the surround into the circuit board control panel.
After the surround has been assembled and is ready to be installed on the unit, plug the wiring harness into the control panel (see Figure 33).
Panel Cover.
Panel Back.
INSTALLATION AND REMOVAL OF THE SURROUND PANELS - FPI AND BIH:
1. Attach one side trim to the top trim, using a corner bracket (see Figure 34) to secure pieces together. There are two (2) main pieces to each corner bracket (see Figure 35). When installing the corner pieces into the trim, the “B FACE” sides must face each other and the screw heads are to face out. With the bracket in place and the top and a side trim snug together, use a flat head screwdriver to turn the two (2) screws in the bracket to tighten it into the trim. Do not over-tighten the corners or the side trim cannot be removed during servicing. 2. Attach the other side trim piece to the top trim, using the same method used in Step 1. 3. Using three (3) T-20 screws on each side attach the hinges on the side surround panels to the unit’s side panels (refer to Figure 37).


4. Plug the wiring harness into the control panel (see Figure 33). 5. Loosen the front hopper lid screws and center the top surround panel under the hopper lid., tighten screws. 6. Insert each side panel anchor bolt through the top panel into the corresponding side panel holes and tighten using a 7/16” wench or socket (refer to Figure 38). 7. Place assembled trim over the surround assembly. On the side trims, there are holes 2” (50 mm) from either end. Use

bracket.
trim.
a Phillips screwdriver to place a #8 screw 11⁄4” long in each hole and tighten just enough to keep the trim against the surround. (refer to Figure 36).


When maintenance is required on the unit the surround must be removed. Follow steps 4 through 7 in reverse order.
The side panel can remain attached because they swing forward for easy access (refer to Figure 39).
the surround.

Figure 37: Panel placed on unit.

Panel, back view.

Put the stainless steel rod through the hole in the heat exchanger located behind the top louvers. Thread the rod into the scraper plate, which is visible from inside the firebox by removing the top baffle.
placement.
This is used to regulate the airflow through the pellet stove.
A Qualified Service Technician or Installer must set the Slider Damper. Taking a reading of vacuum pressure inside the firebox with a magnehelic gauge can be used to set the slider for best combustion. The slider damper should be set only on a hot stove (operating for 30 minutes or more) by placing a Magnehelic Pressure Gauge in the firebox (test port is located in the center of the stove just below the door opening). The best settings are a reading of 0.12 to 0.13 inches of water column (30 Pa) on the high fire setting. Some fuels may require higher or lower settings. The reading can be taken from the 1⁄8” (3 mm) hole located on the front of the unit below the door and behind the magnetic ash lip.

Figure 41: Slider / damper assembly.

WHAT TO DO IF: 1. The stove will not start. 2. The stove will not operate when hot. 3. The exhaust blower will not function normally. 4. The convection blower will not function normally. 5. Ignitor - Everything else in the stove operates but the ignitor will not light the pellets. 6. The auger motor does not function normally. 7. The Dial-A-Fire has no effect on the fire. 8. The 200°F (93°C) high limit temperature sensor has tripped. 9. The stove will not shut off. 10. The stove keeps going out.
*NOTE: All troubleshooting procedures should be carried out by qualified technicians or installers.
(held tight with two screws). ◊ Ensure that the connections to the fifteen (15) minute start-up timer are correct. ◊ Attempt to bypass the switch by inserting a jumper wire between the red and white wires that attach
to the switch. Plug the stove back in. If the stove starts, replace the switch. ◊ If this fails, replace the fifteen (15) minute start-up timer. Caution: Installation of a new start-up timer without checking the ignitor resistance may cause another failure to the new start-up timer due to a short in the ignitor. The proper resistance through the ignitor should be 30Ω to 50Ω ± 3Ω.


auger dial-a-fire, vacuum sensor, 200°F (93°C) temperature sensor and the timing control module against the wiring diagram in this manual. ◊ Check the voltage across the load pins of the timing module. It should be around 1 V to 2 V, cycling
to line voltage during an auger pulse. If not, replace the timing control module. ◊ If the auger motor still does not work, then attempt to by-pass the auger dial-a-fire control by
removing the leads from the timing control module’s second delay pins and placing a jumper across the pins. If the auger now cycles very quickly, test the dial-a-fire potentiometer. If the auger did not cycle, replace the timing control module. ◊ To test the dial-a-fire potentiometer, the potentiometer should have a range of 68KΩ to approximately
850 KΩ (± 10%). If the range is not close, replace the potentiometer.
multimeter into the leads of the potentiometer. The potentiometer should have a range of 68KΩ to approximately 850 KΩ (± 10%). Potentiometer Readings: Full counter-clockwise (switched off) = open circuit, overload or infinite resistance Low fire 800 KΩ to 900 KΩ High fire 68 KΩ to 82 KΩ If the range is not close or does not vary then replace the potentiometer.

against the wiring diagram. ◊ Check the 140°F (60°C) temperature sensor by removing one of the brown wires from the sensor.
The unit should shut down right away as long as the start button was not pressed within 15 minutes of this test. If the stove shuts down within fifteen (15) minutes, replace the 140°F (60°C) sensor. If the stove does not shut down within fifteen (15) minutes, test the switch. ◊ To test the switch, the stove must be cold. Pull the plug, then plug the stove back in. If it fails to start,
replace the switch.
fire is going out before the stove shuts off. ● Check to see that the Slider / Damper is in the correct position. ◊ Turn the Dial-a-Fire up slightly (poor quality pellets will require slightly higher settings).
If the stove goes out and there are partially burned pellets left in the burn pot liner, the stove has shut
If the stove goes out and there are no pellets in the liner, the auger is stopping. ● See “The auger motor will not function normally” and “The exhaust blower will not function normally.”

160oF (71oC) Convection Temperature

200oF (93oC) High Limit Temperature
Sensor


6 High Limit Temperature Sensor 200°F (93°C) Manual Reset EF-016
12 Auger Timer Control (3 second) - 115V EF-036
19 FPI & BIH Hopper Lid Knob & Stud Only EF-059


24 Fireplace Insert Ash Pan Drawer With Latch EF-105
Shoulder Bolt, Hardened Bush & Nut (Set of 2) EF-124
35 Freestanding Hopper Side Rail (Left & Right) EF-143
36 FPI & BIH Hopper Side Rail (Left & Right) EF-145
39 FPI & BIH Ash Pan Cover Magnet Set EF-188
41 FPI & BIH Hopper Lid With Knob, Stud, and Hinge EF-202
Pedestal & Ash Pan Gasket 10’ (3 m) EF-208


45 Stainless Steel Burn Pot Liner - Domestic 50-474
45 Stainless Steel Burn Pot Liner - High Ash 50-587
48 Freestanding Phase Control Panel Complete - 115V 50-678
48 FPI & BIH Phase Control Panel Complete - 115V 50-679
54 Door Cover (No Louvre Trim) - Gold 50-469
54 Door Cover With Louvre Trim - Nickel 50-470
54 Door Cover (No Louvre Trim) - Painted 50-600
57 Built-In Heater Surround Panel - Black Trim EF-077A





Sherwood Industries Ltd. gives a five year limited warranty on all steel manufactured parts. A one-year warranty is provided on all electrical components. The above limited warranties are extended only to the original purchaser.
**NOTE: The paint on the brick firebox lining may peel. This is due to the extreme conditions applied to the paint and is in no way covered under warranty.
WHEN FILING A WARRANTY CLAIM PLEASE COMPLETE THE FOLLOWING INFORMATION ON AN OFFICIAL WARRANTY CLAIM FORM:
TO THE DEALER: - Name and address of dealer, - Date of purchase - Name, address and telephone number of purchaser - Name, address and telephone number of installer - Date of installation, and - Serial number of the appliance
Ensure that you specify the nature of the complaint, defect, periodical malfunction, etc.
TO THE DISTRIBUTOR: - Sign and verify that work and information are correct. - Description and part # of any parts replaced.
The limited warranty covers defects in materials and workmanship as long as the products has been installed according to the manual’s instruction. If the product is damaged or broken as a result of mishandling or misuse, the warranty does not apply. Removal and re-installation costs are not covered under this warranty.
It is the manufacturer’s option whether to repair or replace the appliance. The shipping cost to and from the factory is to be paid by the consumer. All warranties by the manufacturer are set forth herein and no claim shall be made against the manufacturer on any oral warranty or representation.
The manufacturer assumes no responsibility for damage caused by household power fluctuations or power surges.
For the do-it-yourself Individual
The consumer should be aware that the pellet appliance needs setting using tools that he/she might not have. It is recommended that you have a qualified installer install your pellet appliance
Sherwood Industries Ltd. reserves the right to make changes without any notice.
Under Warranty

The following information must be recorded by the installer for warranty purposes and future reference.
NAME OF DEALER:
ADDRESS:
ADDRESS:
PHONE:___________________________________
PHONE:___________________________________
MODEL:___________________________________
NAME OF INSTALLER:
SERIAL NUMBER:___________________________
DATE OF INSTALLATION: (dd/mm/yyyy)
MAGNEHELIC AT INSTALL:___________________
INSTALLER’S SIGNATURE:
PHONE:___________________________________
MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.envirofire.biz September 7, 2006