Instruction/ maintenance manual of the product EF-3 BAYI Sherwood
Go to page of 28
1 ENVIROFIRE PELLET STOVE EF-3 BAYi OWNERS TECHNICAL MANUAL SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD ROAD VICTORIA, BRITISH COLUMBIA V8M-2A3 MODELS FS, FPI and BIH.
ENVIROFIRE INSTALLATION MANUAL TABLE OF CONTENTS INTRODUCTION Important Sa fety Data ........................................................... 3 Pellet Q uality ........................................................................ 4 Warnings and Re commendatio ns.
IMPORTANT SAFETY DATA Please read this entire manual befo re installation and use of this pellet fuel bu rning room heater. Failure to follo w these instructions could result in prop erty damage, bodily injury or even death.
PELLET QUALITY IS IMPORTANT, PLEASE READ THE FOLLOWING PAGE Your pellet stove has been designed to burn wood pellets only. Since there are many manufacturers of wood pellets it is important to select pellets that are free of dirt or any impurities. The Pellet Fuel Industries (P.
WARNINGS AND RECOMMENDATIONS A. Do not abuse the glass by striking or slamming the door shut. B. Do not attempt to operate the stove with broken glass. C. Do not attempt to open the door and clean the glass while the unit is in operation. If you must clean the glass, use a soft cotton cloth and mild window cleaner.
HOW TO START AND OPERATE YOUR PELLET APPLIANCE 1. Check and fill hopper with pellets. 2. Switch on power by pushing the start up switch once only. CONVECTION BLOWER SPEED CONTROL 3. Turn the Dial A Fire knob to the 12 o’clock position. (Lower grade pellets may need a higher setting on the feed rate).
SLIDER/DAMPER INSTALLATION /OPERATION INSTRUCTIONS This is used to regulate the airflow through the pellet stove. INSTALLATION 1. Remove the slider rod (short rod with knob and nuts) and the two nuts from their package and open the left side panel. 2.
AREAS FOR ROUTINE INSPECTION The following should be inspected perio dically to ensure that the a ppliance is operating at it s optimum and giving you excellent heat value: 2-3 DAYS/WEEKLY SEASONALLY .
DOOR GLASS (It is recommended that your dealer replace the glass if broken.) The door glass is made of 5 mm thick, high tempe rature PYROCERAMIC The center panel is 229 mm x 33 0 mm. To replace the glass, unscrew and remove the four glas s retain ers.
ELECTRICAL COMPONENT FUNCTIONS The following is a list of electrical components and their functi ons on the ENVIROFIRE EF-IIIi Bay pellet stove. 1. CONVECTION FAN CONTROL LER This controller is responsib le for varying the speed of the convection blower.
11. 160 ° F (71 ° C) TEMPERATURE SENSOR When this sensor (located on the left side firewall) reache s 160 ° F (71 ° C), the convection blow er will go to high, cooling the unit.
DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE 1. Check clearance s to combustibles. 2. Do not obtain combustion air from an attic, gara ge or any unventilated space. Combustion air may be obtained from a ventilated crawlspace. 3. Do not install the stove in a bedroom.
REMOVING YOUR NEW STOVE FROM IT’S PALLET To remove your new stove from its pallet , open the left and right side panels. There are two wood screws that are holding the bottom of the stove to the pallet. Remove the screws. Close the sid e panels. See PAGE 18 how to install the pedestal.
MASONRY FIREPLACE INSERT INSTALLATION, MODEL FPI The Fireplace Insert model includes surround f ace plates and a pedestal. When installing this unit, ensure that the pedestal is removed from its box and installed on the bottom of the unit. (Surround assembly instructions are in this manual).
ASSEMBLING THE FACE PLATE FOR THE FPI AND BIH MODELS 1. To attach the pedestal, place the unit on its back, making sure not to damage the wiring, then bolt the pedestal onto the unit. Back off the screws on the base, install the pedestal over the screws.
RECOMMENDED FRAMING FOR BUILT IN HEATER When installing model BIH it is recommended that you use the dimensions shown in the diagram below. These type of clearances will make it easy and readily accessible for service. BUILT IN HEATER CLEARANCES TO COMBUSTIBLES This unit includes a 3” (75 mm) pedestal and surrounding faceplates.
FREESTANDING INSTALLATION, MODELS FS CLEARANCES TO COMBUSTIBLES (FREESTANDING) - Side wall to unit A- 6 INCHES (150 mm) - Back wall to unit B- 1 INCH (25 mm) - Corner to unit C- 1 INCH (25 mm) - Mantl.
MODEL FS (FREESTANDING) INSTALLATION PEDESTAL INSTALLATION : Model FS comes with a p edestal that has to be attached prior to installation: - Remove the pedestal from the box - Remove the ENVIROFIRE heater form the box. - Place the unit on its back, making sure not to damage the wiring.
HORIZONTAL EXHAUST THROUGH THE WALL 1. NOTE: Use only listed type “PL” or “L” pellet venting prod ucts . Failure to use listed components may cause damage or personal injury or death.
THROUGH WALL INSTALLATION 1” 20.
FREESTANDING INSIDE VERTICAL INSTALLATION 1. Choose a stove location that is ideal. See the section Deciding Where to Locate Your Pellet Appliance. 2. Place a non-combustible hearth pad where necessary.
FREESTANDING OUTSIDE VERTICAL INSTALLATION To accomplish the above titled installation, follow steps 1 through 8 in the previous section and then finish it by performing the following. 9. Install a tee with clean out on the outside of the house. 10. Install PL vent upward from the tee.
MOBILE HOME INSTALLATION - Secure the heater to the floor using the two bolt holes supplied in the pedestal. - CAUTION: THE STUCTURAL INT EGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. - Ensure the unit is electrically grounded to the chassis of your home (permanently).
TROUBLESHOOTING DO NOT: - Hold the start-up switch down, this is a momentary contact switch and can be damaged if held down too long. - Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly.
4. The convection blower will not function normally - Check all the connections between the contro ller, switch, and the convection blower against the wiring diagram. - If the convection motor will not run, apply 230V AC to the motor directly. If the m otor runs, replace the fan controller.
placing a jumper across the pins. If the auger now cycles very quickly, test the dial-a-fire potentiometer. If the auger did not cycle then replace the timing control module.
WIRING DIAGRAM 27.
WARRANTY Sherwood Industries Ltd. gives a five y ear limited warr anty on all steel manufa ctured parts. A one year warra nty is provided on all ele ctrical components.
An important point after buying a device Sherwood EF-3 BAYI (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Sherwood EF-3 BAYI yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Sherwood EF-3 BAYI - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Sherwood EF-3 BAYI you will learn all the available features of the product, as well as information on its operation. The information that you get Sherwood EF-3 BAYI will certainly help you make a decision on the purchase.
If you already are a holder of Sherwood EF-3 BAYI, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Sherwood EF-3 BAYI.
However, one of the most important roles played by the user manual is to help in solving problems with Sherwood EF-3 BAYI. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Sherwood EF-3 BAYI along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center