Instruction/ maintenance manual of the product Sherborne Wood & Multifuel Stoves Aarrow Fires
Go to page of 32
Arada Ltd The Fireworks Bridport Dorset, DT6 3BE Great Britain T el. (44) 01308 427234 Fax. (44) 01308 423441 www .aarrowfires.com Wood & Multifuel Stoves Operating & Installation Manual PLEAS.
Congratulations on your choice of an Aarrow Stove. More than 20 years experience has been put into the development of our Sherborne, range to ensure ultimate performance and years of trouble free enjoyment.
INTRODUCTION Page Safety Notices 5 The Principle of the Fire 5 Check List 6 T echnical Data 7 OPERA TING INSTRUCTIONS Firebox Linings and Throat Plate Removal 8 Multifuel Grate 8 W ood Stove - W ood T.
W ARNING T O ALL MUL TIFUEL USERS PETROLEUM COKE SOME OF WHOSE BRAND NAMES ARE "CALCO", "PETROCOKE" OR "WONDERCO" MUST NOT BE BURNED IN THIS APPLIANCE T O USE THESE FUELS WILL INV ALIDA TE THE APPLIANCE GUARANTEE IF IN DOUBT CONT ACT THE SOLID FUEL ASSOCIA TION TELEPHONE NUMBER 0800 600 000 www .
Sherborne Wood & Multifuel S toves 5 INTRODUCTION SAFETY A fireguard conforming to BS 8423: 2002 should be used in the presence of children and old/or infirm people. If the appliance is used with the fire door open, a spark guard conforming to BS 3248 should be fitted.
6 Sherborne Wood & Multifuel S toves CHECK LIST 1 1. Multifuel riddling kit optional accessory N/A 12. Instructions 1 10. W oodburning tray 1 optional accessory 7 Part Description & V isual Aid (not to scale) Sherborne Small Multifuel 2 1 4. Flue spigot 1 (5”) 5.
Sherborne Wood & Multifuel S toves 7 TECHNICAL DA T A Room Min/Max Room Heater Only Output (kW) 1.5 - 6 TECHNICAL DA T A Sherborne Small Multifuel Room Heater with Domestic Hot W ater with add in .
FIREBOX LININGS & THROA T PLA TE The Sherborne range of W ood and Multifuel stoves firebox have reflective liners to the sides and rear and a specially shaped throat plate which sits on the liners. If these are not in place please refer to page 17 to install these.
Fig. 4b Lifting cover fr om body of stove Fig. 4c Unscrewing MUL TI - PURPOSE OPERA TING T OOL Y our Aarrow fire comes with a multi-purpose tool, which is used for riddling, setting the multifuel grate position. Use the operating tool for setting the grate in the coal burning position or the wood burning position.
DOOR ADJUSTMENT Once the appliance has been under fire for a period of time the fire door may appear to have moved out of alignment with relation to the door aperture.
FUEL TYPES W ood- Any type of wood is suitable provided it is well seasoned and has a moisture content below 20%. This usually implies that the timber has been suitably stored to allow moisture to evaporate for at least nine months in the case of soft woods, and at least eighteen months in the case of hard wood.
ENSURE THA T YOU HA VE READ & UNDERSTOOD THESE INSTRUCTIONS BEFORE LIGHTING THE FIRE. AL W A YS WEAR SUIT ABLE PROTECTIVE FIRE GLOVES WHEN REFUELLING YOUR STOVE. SOLID FUEL BURNING •Set the grate to ‘coal’ position. •Ensure that the ash pan is in position and the fire doors are closed.
• Check for flue or chimney blockage, and clean if required. Seek expert advice fr om your HET AS r egistered installer . Do not attempt to re-light the fir e until the cause of the fume emission has been identified and corr ected.
Remove the firebricks lining and throat plate, inspect all gasketing on doors, glass etc., and re-order any items that may need replacing, from your Aarrow dealer . W ith a wire brush clean inside the appliance paying particular attention to the small inlet holes of the air wash on the inside, above the fire door and to the door .
Sherborne Wood & Multifuel S toves 15 ACCESSORIES ACCESSORIES WOOD BURNING TRA YS T o turn your multifuel stove into a dedicated woodburner . As shown in Fig. 10a below MUL TIFUEL UPGRADE KIT A vailable for the wood burning range to enable you to burn solid fuel in your Sherborne woodburning stove.
16 Sherborne Wood & Multifuel S toves INST ALLA TION GENERAL PRECAUTIONS Note - All installations must conform to the appropriate building regulations. The Building Regulations for England and W ales 2000 ref Approved Document J 2002 edition (issued by the DTLR).
Sherborne Wood & Multifuel S toves 17 INST ALLA TION FIREBOX LINER P ANELS The Sherborne W ood and Multifuel stoves use reflective liners to the sides and back. The throat plate sits on top of the side and rear panels. These should come fitted to your fire, if however they are not proceed as follows to fit them.
MUL TIFUEL GRA TE GRA TE The grates in the Sherborne Multifuel units comprise a series of reciprocating cast iron bars seated on a pivoted "comb".
INTERCHANGEABLE CANOPIES The canopy versions for the Sherborne range are slab top stoves to which a low or high canopy can be fitted after installation and ar e interchangeable. These are fitted as follows: •T o fit the interchangeable canopy (Fig 10c): •Remove the front clamps.
20 Sherborne Wood & Multifuel S toves INST ALLA TION FITTING THE FLUE OUTLET AND HOT PLA TE The flue outlet spigot is found inside the appliance. The hot plate (blanking plate) is supplied fitted to the top opening and is removed by turning clockwise (as is the flue outlet).
Due to the gradual introduction of European Chimney Standards chimneys will be specified according to their performance designation as defined in BS EN 1443 that covers the General Requirements for chimneys. The minimum performance designation required for use with solid fuel burning stoves is T450 N2 S D3.
22 Sherborne Wood & Multifuel S toves INST ALLA TION.
Sherborne Wood & Multifuel S toves 23 INST ALLA TION P LAN V IEW OF REGISTER PLA TE AND CLEARANCES FOR NON INSULA TED FLUES T YPICAL M ET AL I NSULA TED C HIMNEY S YSTEM T O BE INST ALLED TO THE CHIMNEY MANUF ACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULA TIONS AND BS7566 P TS 1-4 A is minimum clearance for non-insulated flue = 1.
24 Sherborne Wood & Multifuel S toves INST ALLA TION ADD IN BOILERS Sherborne W ood and Multifuel stoves offer the option of a slab boiler , which occupies the position of the rear firebox liner panels. Fitting: •Remove the fuel retainers, rear firebox liner panels and throat plate.
Sherborne Wood & Multifuel S toves 25 INST ALLA TION Primary flow and return pipes should be 28mm diameter . The cylinder should be installed at a higher level than the appliance, and as close to it as possible (the higher the cylinder the faster the circulation).
26 Sherborne Wood & Multifuel S toves INST ALLA TION CHECKLIST Hearths, Fir eplaces, Flues and chimneys This checklist is to ensure hearths, fireplaces, flues and chimneys are satisfactory , and to show what you have done to comply with the requirements of The Building Regulations 2000 Approved Document J 2002.
Sherborne Wood & Multifuel S toves 27 P AR TS LIST 1. Fuel Retainers AFS1 192 AFS1 192 AFS1191 AFS1019 AFS1019 AFS1020 N/A AFS001 N/A AFS009 AFS009 AFS009 AFS008 AFS008 AFS008 AFS058 AFS058 AFS051 AFS010 AFS010 AFS010 2. Throat Plate 3. Grate Bar Set 4.
28 Sherborne Wood & Multifuel S toves P AR TS LIST 8. Liner Set AFS1 156 AFS1 156 AFS1 163 AFS1058 AFS1058 AFS1 164 AFS1 157 AFS1 157 AFS1 165 AFS1009 AFS1009 AFS1095 AFS1010 AFS1010 AFS1010 AFS047 AFS047 AFS047 AFS1233 AFS1233 AFS1233 9. Side Liner 10.
Sherborne Wood & Multifuel S toves 29 P AR TS LIST 16. Fire Door Rope Kit Complete with Door Rope Glue. AFS1021 AFS1021 AFS1021 AFS1021 L/H AFS1234 R/H AFS1235 L/H AFS1234 R/H AFS1235 L/H AFS1238 .
Guarantee Once again we would like to thank you for buying a Sherborne fire. When you buy an Aarrow Fire, you are not only buying a first class appliance - you are buying a commitment from us to look after you and your appliance for as long as you want.
Should you have any questions about your Sherborne W ood or Multifuel Stove that is not covered in this manual please contact your Aarrow retailer . Please keep all repair receipts safely . Please ensure you have this manual available when an engineer visits as they will complete the service record chart.
FINAL F ACTOR Y CHECK LIST BK046 QUALITY FINISH PA R T S FLUE OUTLET HOT PLA TE FUEL RET AINERS X2 GRA TE BARS / WOOD TRA Y FIREBOX LININGS THROA T PLA TE AIR W ASH DOOR CA TCH ASH P AN OPERA TING TOOL OPERA TING INSTRUCTIONS Model....................
An important point after buying a device Aarrow Fires Sherborne Wood & Multifuel Stoves (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Aarrow Fires Sherborne Wood & Multifuel Stoves yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Aarrow Fires Sherborne Wood & Multifuel Stoves - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Aarrow Fires Sherborne Wood & Multifuel Stoves you will learn all the available features of the product, as well as information on its operation. The information that you get Aarrow Fires Sherborne Wood & Multifuel Stoves will certainly help you make a decision on the purchase.
If you already are a holder of Aarrow Fires Sherborne Wood & Multifuel Stoves, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Aarrow Fires Sherborne Wood & Multifuel Stoves.
However, one of the most important roles played by the user manual is to help in solving problems with Aarrow Fires Sherborne Wood & Multifuel Stoves. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Aarrow Fires Sherborne Wood & Multifuel Stoves along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center