EN
Desa Tech logo
Official user manual

Desa Tech Gas Log Set (18)

32 pages·358 KB·Gas Heater·PDF·ENDEFRITNLJA
Desa Tech Gas Log Set (18)
Table of Contents 73 sections BLUE FLAME VENT-FREE NATURAL GAS HEATER · OWNER’S OPERATION AND INSTALLATION MANUAL · Heater Sizes: 18,000 Btu/Hr Thermostat, and 28,000 Btu/Hr Thermostat “B” Model Heaters · — WHAT TO DO IF YOU SMELL GAS · … ShowHide
BLUE FLAME VENT-FREE NATURAL GAS HEATERp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1Heater Sizes: 18,000 Btu/Hr Thermostat, and 28,000 Btu/Hr Thermostat “B” Model Heatersp.1— WHAT TO DO IF YOU SMELL GASp.1— Installation and service must be performed by a qualified installer, servicep.1CONTENTS SECTION PAGEp.2SAFETY INFORMATIONp.2WARNING ICON G 001 DANGER Carbon monoxide poisoning may lead to death!p.2WARNING ICON G 001 WARNINGS Continuedp.3PRODUCT IDENTIFICATIONp.4PRODUCT FEATURESp.4FRESH AIRp.5WARNING ICON G 001 WARNINGp.5FOR COMBUSTIONp.5AND VENTILATIONp.5DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONp.6INSTALLINGp.9TO WALLp.9WARNING ICON G 001 WARNING Never install the heaterp.9CEILINGp.10FLOORp.10CONNECTINGp.14TO GAS SUPPLYp.14WARNING ICON G 001 CAUTIONp.14CHECKINGp.15GAS CONNECTIONSp.15PRESSURE TESTING GAS SUPPLY PIPING SYSTEMp.15PRESSURE TESTING HEATER GAS CONNECTIONSp.16ON POSITIONp.16OFF POSITIONp.16OPERATINGp.17FOR YOUR SAFETY READ BEFORE LIGHTINGp.17HEATERp.17WHAT TO DO IF YOU SMELL GASp.17LIGHTING INSTRUCTIONSp.17LOp.17PILOTp.17OFFp.17HIp.17IGNITORp.17TO TURN OFF GAS TO APPLIANCE OPERATINGp.19THERMOSTAT CONTROL OPERATIONp.19MANUAL LIGHTING PROCEDUREp.19INSPECTINGp.20BURNERp.20NOTICEp.211/2 GLASS HEIGHTp.21CORRECT FLAME PATTERNp.21AT HIGH POSITIONp.21INCORRECT FLAME PATTERNp.21CLEANINGp.22AND MAINTENANCEp.22ODS/PILOT AND BURNERp.22CABINETp.22TROUBLESHOOTINGp.22OBSERVED PROBLEMp.22POSSIBLE CAUSEp.22REMEDYp.22WARNING ICON G 001 WARNING If you smell gasp.25TECHNICALp.26SERVICEp.26SPECIFICATIONSp.26HINTSp.26SERVICE PUBLICATIONSp.26REPLACEMENTp.27PARTSp.27PARTS CENTRALSp.27PARTS AVAILABLE — NOT SHOWNp.29NOTES _________________________________________________________________p.31WARRANTY INFORMATIONp.32KEEP THIS WARRANTYp.32LIMITED WARRANTY COMFORT GLOW VENT-FREE NATURAL GAS HEATERSp.32101808-01 REV. C 3/96p.32
Page 1 of the Desa Tech Gas Log Set (18) user manual — — Installation and service must be performed by a qualified installer, service
Page 1 · click to enlarge
Page 1

BLUE FLAME VENT-FREE NATURAL GAS HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

Heater Sizes: 18,000 Btu/Hr Thermostat, and 28,000 Btu/Hr Thermostat “B” Model Heaters

— Do not store or use gasoline or other flammable vapors and liquids in the

vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

— Installation and service must be performed by a qualified installer, service

agency, or the gas supplier.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

Save this manual for future reference.

®

Page 2 of the Desa Tech Gas Log Set (18) user manual — Table of Contents
Page 2 · Contents
Contents

Contents

BLUE FLAME VENT-FREE NATURAL GAS HEATERp.1OWNER’S OPERATION AND INSTALLATION MANUALp.1Heater Sizes: 18,000 Btu/Hr Thermostat, and 28,000 Btu/Hr Thermostat “B” Model Heatersp.1— WHAT TO DO IF YOU SMELL GASp.1— Installation and service must be performed by a qualified installer, servicep.1CONTENTS SECTION PAGEp.2SAFETY INFORMATIONp.2WARNING ICON G 001 DANGER Carbon monoxide poisoning may lead to death!p.2WARNING ICON G 001 WARNINGS Continuedp.3PRODUCT IDENTIFICATIONp.4PRODUCT FEATURESp.4FRESH AIRp.5WARNING ICON G 001 WARNINGp.5FOR COMBUSTIONp.5AND VENTILATIONp.5DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONp.6INSTALLINGp.9TO WALLp.9WARNING ICON G 001 WARNING Never install the heaterp.9CEILINGp.10FLOORp.10CONNECTINGp.14TO GAS SUPPLYp.14WARNING ICON G 001 CAUTIONp.14CHECKINGp.15GAS CONNECTIONSp.15PRESSURE TESTING GAS SUPPLY PIPING SYSTEMp.15PRESSURE TESTING HEATER GAS CONNECTIONSp.16ON POSITIONp.16OFF POSITIONp.16OPERATINGp.17FOR YOUR SAFETY READ BEFORE LIGHTINGp.17HEATERp.17WHAT TO DO IF YOU SMELL GASp.17LIGHTING INSTRUCTIONSp.17LOp.17PILOTp.17OFFp.17HIp.17IGNITORp.17TO TURN OFF GAS TO APPLIANCE OPERATINGp.19THERMOSTAT CONTROL OPERATIONp.19MANUAL LIGHTING PROCEDUREp.19INSPECTINGp.20BURNERp.20NOTICEp.211/2 GLASS HEIGHTp.21CORRECT FLAME PATTERNp.21AT HIGH POSITIONp.21INCORRECT FLAME PATTERNp.21CLEANINGp.22AND MAINTENANCEp.22ODS/PILOT AND BURNERp.22CABINETp.22TROUBLESHOOTINGp.22OBSERVED PROBLEMp.22POSSIBLE CAUSEp.22REMEDYp.22WARNING ICON G 001 WARNING If you smell gasp.25TECHNICALp.26SERVICEp.26SPECIFICATIONSp.26HINTSp.26SERVICE PUBLICATIONSp.26REPLACEMENTp.27PARTSp.27PARTS CENTRALSp.27PARTS AVAILABLE — NOT SHOWNp.29NOTES _________________________________________________________________p.31WARRANTY INFORMATIONp.32KEEP THIS WARRANTYp.32LIMITED WARRANTY COMFORT GLOW VENT-FREE NATURAL GAS HEATERSp.32101808-01 REV. C 3/96p.32
Page 3 of the Desa Tech Gas Log Set (18) user manual — WARNING ICON G 001 WARNINGS Continued
Page 3 · click to enlarge
Page 3

SAFETY INFORMATION

WARNING ICON G 001 WARNINGS Continued

  • 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 3. This heater shall not be installed in a bedroom or bathroom. 4. Never install the heater
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
  • as a fireplace insert
  • in high traffic areas
  • in windy or drafty areas 5. This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Fresh Air for Combustion and Ventilation, pages 5 through 8. 6. Never run heater in small, closed room. 7. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced. 8. Do not run heater
  • where flammable liquids or vapors are used or stored
  • under dusty conditions 9. Never place any objects on the heater. 10. Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut-down. Allow surface to cool before touching. 11. Carefully supervise young children when they are in the same room with heater. 12. Make sure grill guard is in place before running heater. 13. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 14. Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater. 15. Operating heater above elevations of 4,500 feet could cause pilot outage.
Page 4 of the Desa Tech Gas Log Set (18) user manual — PRODUCT FEATURES
Page 4 · click to enlarge
Page 4

Ignitor Button Control Knob

PRODUCT IDENTIFICATION

Figure 1 - Vent-Free Natural Gas Heater (28,000 Btu/Hr Model Shown)

LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the National Fuel Gas Code ANSI Z223, also known as NFPA 54*.

*Available from: American National Standards Institute, Inc.

1430 Broadway New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park Quincy, MA 02269

UNPACKING 1. Remove heater from carton. 2. Remove all protective packaging applied to heater for shipment. 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

PRODUCT FEATURES

Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

Piezo Ignition System This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

Thermostatic Heat Control Thermostat models have a thermostat sensing bulb and a control valve. This results in the greatest heater comfort. This can also result in lower gas bills.

Show 4 more labels / short text on this page
Grill Guard · Glass Panel · Front Panel · Heater Cabinet
Page 5 of the Desa Tech Gas Log Set (18) user manual — AND VENTILATION
Page 5 · click to enlarge
Page 5

FRESH AIR

WARNING ICON G 001 WARNING

FOR COMBUSTION

This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

AND VENTILATION

Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation. Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

PROVIDING ADEQUATE VENTILATION The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Contruction; 2. Unconfined Space; 3. Confined Space. The information on pages 5 through 7 will help you classify your space and provide adequate ventilation. Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continu-

ous water vapor retarder with a rating of one perm or less with open- ings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window

and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide addi- tional fresh air. See Ventilation Air From Outdoors, page 8. If your home does not meet all of the three criteria above, proceed to page 6.

Unconfined Space The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines uncon- fined space as having a minimum air volume of 50 cubic feet (127 cubic cm) for each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passageways or ventilation grills between the rooms. Confined Space The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines confined space as having an air volume of less than 50 cubic feet (127 cubic cm) for each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passageways or ventilation grills between the rooms.

Page 6 of the Desa Tech Gas Log Set (18) user manual — AND VENTILATION
Page 6 · click to enlarge
Page 6

FRESH AIR

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

FOR COMBUSTION

Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

AND VENTILATION

1. Determine the volume of the space (length x width x height).

Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

(volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)

3. Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr

Example: Gas water heater 40,000 Btu/Hr Vent-free heater + 18,000 Btu/Hr Total = 58,000 Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used)

Example51,200 Btu/Hr (maximum the space can support) 58,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A. Rework worksheet, adding the space of an adjoining room. If the extra space provides

an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7. B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 8. C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Page 7 of the Desa Tech Gas Log Set (18) user manual — FOR COMBUSTION
Page 7 · click to enlarge
Page 7

FRESH AIR

FOR COMBUSTION

AND VENTILATION

VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Ventilation Grills Into Adjoining Room,

Or Remove Door into Adjoining

Figure 2 - Ventilation Air from Inside Building

Show 7 more labels / short text on this page
12" · Ventilation · Option 2 · Grills into Adjoining · Room, Option 1 · Room, Option 3 · 12"
Page 8 of the Desa Tech Gas Log Set (18) user manual — FOR COMBUSTION
Page 8 · click to enlarge
Page 8

FRESH AIR

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

FOR COMBUSTION

AND VENTILATION

Inlet Air Ventilated Crawl Space

Figure 3 - Ventilation Air from Outdoors

Show 6 more labels / short text on this page
Ventilated Attic · Outlet Air · Outlet Air · To Attic · To Crawl Space · Inlet Air
Page 9 of the Desa Tech Gas Log Set (18) user manual — WARNING ICON G 001 WARNING Never install the heater
Page 9 · click to enlarge
Page 9

INSTALLING

TO WALL

CHECK GAS TYPE Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION ITEMS Before installing heater, make sure you have the items listed below.

  • piping (check local codes)
  • sealant (resistant to propane/LP gas)
  • manual shutoff valve *
  • ground joint union
  • test gauge connection * (see Figure 13, page 15)
  • sediment trap
  • tee joint
  • pipe wrench * An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories , page 30.

LOCATING HEATER This heater is designed to be mounted on a wall.

You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accessories, page 30.

WARNING ICON G 001 WARNING Never install the heater

  • in a bedroom or a bathroom
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
  • as a fireplace insert
  • in high traffic areas
  • in windy or drafty areas
Page 10 of the Desa Tech Gas Log Set (18) user manual — FLOOR
Page 10 · click to enlarge
Page 10

INSTALLING

TO WALL

  • heater pilot and burner must be at least 18 inches above floor
  • locate heater where moving vehicle will not hit it

For convenience and efficiency, install heater

  • where there is easy access for operation, inspection, and service
  • in coldest part of room

An optional fan kit is available from your dealer. See Accessories, page 30. If planning to use fan, locate heater near an electrical outlet.

CEILING

Minimum From Sides Of Heater

Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material

FLOOR

Figure 4 - Mounting Clearances As Viewed From Front of Heater

THERMOSTAT SENSING BULB The thermostat sensing bulb has been placed inside the heater for protection during shipping.

Locating Thermostat Sensing Bulb 1. Remove front panel of heater (see Figure 7, page 11). 2. Locate thermostat sensing bulb just under burner assembly. IMPORTANT: Attach thermostat sensing bulb to back of heater for proper operation.

Attaching Thermostat Sensing Bulb 1. Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater. 2. Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in hardware package. 3. Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up.

Figure 5 - Attaching Thermostat Sensing Bulb

Show 8 more labels / short text on this page
36" · Minimum · 6" · Left Side · Right Side · 3" · Thermostat Sensing Bulb · Clamp
Page 11 of the Desa Tech Gas Log Set (18) user manual — TO WALL
Page 11 · click to enlarge
Page 11

INSTALLING

INSTALLING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel.

TO WALL

Figure 6 - Bracket Location

Removing Front Panel Of Heater 1. Remove two screws near bottom corners of front panel. 2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4". 3. Pull bottom of front panel forward, then downward. 4. Remove cardboard packing from grill and glass.

Figure 7 - Removing Front Panel Of Heater

Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall in one of two ways.

1. Attaching to wall stud 2. Attaching to wall anchor

Attaching to wall stud This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching to wall anchor This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Mounting Bracket

Page 12 of the Desa Tech Gas Log Set (18) user manual — TO WALL
Page 12 · click to enlarge
Page 12

INSTALLING

Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mount- ing bracket is level.

TO WALL

2. Mark screw locations on wall (see Figure 8). Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only. 3. Remove tape and mounting bracket from wall.

11" Min.

7 1/4" Min.

Only Insert Mounting Screws Through Last

18 3/4" Min.

Only Insert Mounting Screws Through Last

18 3/4" Min.

Hole On Each End

Hole On Each End

28,000 Btu/Hr Model 18,000 Btu/Hr Models

Figure 8 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater.

Attaching to wall stud method For attaching mounting bracket to wall studs 1. Drill holes at marked locations using 9/64" drill bit. 2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall. 3. Insert mounting screws through bracket and into wall studs. 4. Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to wall anchor method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep. 2. Fold wall anchor as shown in Figure 9.

Figure 9 - Folding Anchor

3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall.
Show 5 more labels / short text on this page
16" · 16" · Adjoining Wall · Adjoining Wall · Floor Floor
Page 13 of the Desa Tech Gas Log Set (18) user manual — TO WALL
Page 13 · click to enlarge
Page 13

INSTALLING

4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

TO WALL

Figure 10 - Popping Open Anchor Wings For Thin Walls

5. Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors. 6. Insert mounting screws through bracket and into wall anchors. 7. Tighten screws until mounting bracket is firmly fastened to wall.

Placing Heater On Mounting Bracket 1. Locate two horizontal slots on back panel of heater. 2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Mounting Bracket (attached to wall)

Figure 11 - Mounting Heater Onto Mounting Bracket

Installing Bottom Mounting Screws 1. Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see Figure 12). 2. Mark screw locations on wall. 3. Remove heater from mounting bracket. 4. If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching To Wall Anchor Method, page 12. If installing bottom mounting screw into wall stud, drill holes at marked loca- tions using 9/64" drill bit. 5. Replace heater onto mounting bracket. 6. Place spacers between bottom mounting holes and wall anchor or drilled hole. 7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole. 8. Tighten both screws until heater is firmly secured to wall. Do not over tighten. Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 14-16).

Figure 12 - Installing Bottom Mounting Screws

Horizontal Slots · Stand-Out Tab

Page 14 of the Desa Tech Gas Log Set (18) user manual — WARNING ICON G 001 CAUTION
Page 14 · click to enlarge
Page 14

CONNECTING

TO GAS SUPPLY

WARNING ICON G 001 CAUTION

Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large enough diameter to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Typical Pipe Diameters 18,000 Btu/Hr Models 3/8" or greater 28,000 Btu/Hr Model 1/2" or greater

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13, page 15).

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Install sediment trap in supply line as shown in Figure 13, page 15. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

Page 15 of the Desa Tech Gas Log Set (18) user manual — PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Page 15 · click to enlarge
Page 15

CONNECTING

TO GAS SUPPLY

1/2" NPT Pipe Nipple

Manual Shutoff Valve *

Test Gauge Connection *

Reducer Bushing to 1/8" NPT

From Gas Meter (4" W.C. to 10.5" W.C. Pressure)

1/8" NPT Plug Tap

Figure 13 - Gas Connection

* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 30.

CHECKING

GAS CONNECTIONS

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG 1. Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where manual shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

Show 10 more labels / short text on this page
Pressure Regulator · Heater Cabinet · Ground Joint Union · Tee Joint · Tee Joint · Sediment · Pipe Nipple · Trap · 3" Minimum · Cap
Page 16 of the Desa Tech Gas Log Set (18) user manual — ON POSITION
Page 16 · click to enlarge
Page 16

CHECKING

4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once.

GAS CONNECTIONS

Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 14). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to manual shutoff valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS

1. Open manual shutoff valve (see Figure 14). 2. Open main gas valve located on or near gas meter. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from manual shutoff valve to thermostat gas valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, pages 17 through 19). Check the rest of the internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 19). 8. Replace front panel.

ON POSITION

OFF POSITION

Figure 14 - Manual Shutoff Valve

Figure 15 - Checking Gas Joints

Show 6 more labels / short text on this page
Open · Manual Shutoff Valve · Closed · Thermostat Gas Valve · Gas Meter · Manual Shutoff Valve
Page 17 of the Desa Tech Gas Log Set (18) user manual — LO
Page 17 · click to enlarge
Page 17

OPERATING

FOR YOUR SAFETY READ BEFORE LIGHTING

HEATER

A. This appliance has a pilot which must be lighted by hand. When lighting

the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure

to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use

tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately

call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information above.
2. Make sure manual shutoff valve is fully open.
3. Turn control knob clockwise Clockwise to the OFF position.

Ignitor Button Control Knob

LO

PILOT

OFF

HI

IGNITOR

Figure 16 - Control Knob In The OFF Position

Page 18 of the Desa Tech Gas Log Set (18) user manual — HEATER
Page 18 · click to enlarge
Page 18

OPERATING

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 17. If you don’t smell gas, go to the next step.

HEATER

5. Turn control knob counterclockwise C-clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 16).
  • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.
6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Figure 17 - Pilot

8. Turn control knob counterclockwise C-clockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

Ignitor Electrode · Thermocouple · Pilot Burner

Page 19 of the Desa Tech Gas Log Set (18) user manual — MANUAL LIGHTING PROCEDURE
Page 19 · click to enlarge
Page 19

TO TURN OFF GAS TO APPLIANCE OPERATING

HEATER Shutting Off Heater 1. Turn control knob clockwise Clockwise to the OFF position.

2. Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT CONTROL OPERATION

The thermostatic control used on these models differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO.

MANUAL LIGHTING PROCEDURE

1. Remove front panel (see Figure 7, page 11).
2. Follow steps 1 through 5 under Lighting Instructions , pages 17 and 18.
3. With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
5. Replace front panel.
Page 20 of the Desa Tech Gas Log Set (18) user manual — BURNER
Page 20 · click to enlarge
Page 20

INSPECTING

Check pilot flame pattern and burner flame pattern often.

BURNER

PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Figure 18 - Correct Pilot Flame Pattern

Figure 19 - Incorrect Pilot Flame Pattern

Thermocouple Pilot Burner · Pilot Burner Thermocouple

Page 21 of the Desa Tech Gas Log Set (18) user manual — 1/2 GLASS HEIGHT
Page 21 · click to enlarge
Page 21

INSPECTING

If pilot flame pattern is incorrect, as shown in Figure 19.

  • turn heater off (see To Turn Off Gas to Appliance , page 19).
  • see Troubleshooting , pages 22 through 25.

BURNER

BURNER FLAME PATTERN Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows yellow tipping of the flame. It also shows the flame higher than 1/2 the glass panel height.

NOTICE

Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.

1/2 GLASS HEIGHT

CORRECT FLAME PATTERN

AT HIGH POSITION

Figure 20 - Correct Burner Flame Pattern

1/2 GLASS HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

Figure 21 - Incorrect Burner Flame Pattern

If burner flame pattern is incorrect, as shown in Figure 21

  • turn heater off (see To Turn Off Gas to Appliance , page 19)
  • see Troubleshooting , pages 22 through 25

Yellow Tipping

Page 22 of the Desa Tech Gas Log Set (18) user manual — OBSERVED PROBLEM
Page 22 · click to enlarge
Page 22

CLEANING

AND MAINTENANCE

ODS/PILOT AND BURNER

  • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

  • Air Passageways
  • Use a vacuum cleaner or pressurized air to clean. Exterior
  • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1. Ignitor electrode positioned wrong 2. Ignitor electrode broken 3. Ignitor electrode not connected to ignitor cable 4. Ignitor cable pinched or wet
1. Replace ignitor
2. Replace ignitor 3. Reconnect ignitor cable
4. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 5. Tighten nut holding piezo ignitor to heater cabinet. Nut is located inside heater cabinet at top 6. Replace ignitor cable 7. Replace piezo ignitor
5. Piezo ignitor nut is loose
6. Broken ignitor cable 7. Bad piezo ignitor
Page 23 of the Desa Tech Gas Log Set (18) user manual — OBSERVED PROBLEM
Page 23 · click to enlarge
Page 23

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or manual shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Clean ODS/pilot (see Cleaning and Maintenance , page 22) or replace ODS/pilot assembly 6. Replace gas regulator
5. ODS/pilot is clogged
6. Gas regulator setting is not correct

ODS/pilot lights but flame goes out when control knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 30 seconds 3. Wait one (1) minute for safety interlock system to reset. Repeat ignition operation 4. Fully open manual shut-off valve 5. Hand tighten until snug, then tighten 1/4 turn more 6. A) Contact local natural gas company B) Clean ODS/pilot (see Cleaning and Maintenance , page 22) or replace ODS/pilot assembly
3. Safety interlock system has been triggered (Thermostat models only) 4. Manual shutoff valve not fully open 5. Thermocouple connection loose at control valve 6. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot 7. Thermocouple damaged 8. Control valve damaged
7. Replace thermocouple
8. Replace control valve
Page 24 of the Desa Tech Gas Log Set (18) user manual — OBSERVED PROBLEM
Page 24 · click to enlarge
Page 24

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1. Burner orifice is clogged
1. Clean burner (see Cleaning and Maintenance , page 22) or replace burner orifice 2. Replace burner orifice
2. Burner orifice diameter is too small 3. Inlet gas pressure is too low
3. Contact local natural gas company

Delayed ignition of burner

1. Manifold pressure is too low 2. Burner orifice is clogged
1. Contact local natural gas company 2. Clean burner (see Cleaning and Maintenance , page 22) or replace burner orifice

Burner backfiring during combustion

1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Maintenance , page 22) or replace burner orifice 2. Replace burner 3. Replace gas regulator
2. Burner damaged 3. Gas regulator defective

Yellow flame during burner combustion

1. Not enough air
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance , page 22) 2. Replace gas regulator
2. Gas regulator defective

Slight smoke or odor during initial opera- tion

1. Residues from manufacturing processes
1. Problem will stop after a few hours of operation

Heater produces a whistling noise when burner is lit

1. Turning control knob to HI position when burner is cold 2. Air in gas line
1. Turn control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local natural gas company 3. Observe minimum installation clearances (see Figure 4, page 10) 4. Clean burner (see Cleaning and Maintenance , page 22) or replace burner orifice
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orifice
Page 25 of the Desa Tech Gas Log Set (18) user manual — OBSERVED PROBLEM
Page 25 · click to enlarge
Page 25

TROUBLESHOOTING

WARNING ICON G 001 WARNING If you smell gas

  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person

Heater produces unwanted odors

1. Heater burning vapors from paint, hair spray, glues, etc. See IMPORTANT statement above). 2. Gas leak. See Warning statement at top of page
1. Ventilate room. Stop using odor causing products while heater is running
2. Locate and correct all leaks (see Checking Gas connections , page 15)

Heater shuts off in use (ODS operates)

1. Not enough fresh air is available 2. Low line pressure
1. Open window and/or door for ventilation 2. Contact local natural gas company 3. Clean ODS/pilot (see Cleaning and Maintenance , page 22)
3. ODS/pilot is partially clogged

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at top of page 2. Control valve defective
1. Locate and correct all leaks (see Checking Gas Connections , page 15) 2. Replace control valve

Gas odor during combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections , page 15)

Moisture/condensa- tion noticed on windows

1. Not enough combustion/ventilation air.
1. Refer to Fresh Air for Combustion and Ventilation requirements (page 5)
Page 26 of the Desa Tech Gas Log Set (18) user manual — SERVICE PUBLICATIONS
Page 26 · click to enlarge
Page 26

TECHNICAL

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

SERVICE

SPECIFICATIONS

18,000 Btu/Hr 28,000 Btu/Hr Models Model

B.T.U (Variable) 9,000/18,000 14,000/28,000 Type Gas Natural Only Natural Only

Ignition Piezo Piezo Pressure Regulator Setting 3" W.C. 3" W.C.

Inlet Gas Pressure (in. of water)

Maximum 10.5" 10.5" Minimum 4" 4"

Dimensions, Inches (H x W x D)

Heater 23.5 x 18.5 x 8.0 23.5 x 25.9 x 8.0 Carton 25.8 x 21.3 x 10.1 25.8 x 28.7 x 10.1

Heater 22 30 Shipping 27 35

SERVICE

When gas pressure is too low

  • pilot will not stay lit
  • burner will have delayed ignition
  • heater will not produce specified heat

HINTS

When gas quality is bad

  • pilot will not stay lit
  • burner will produce flames and soot
  • heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier.

SERVICE PUBLICATIONS

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

Weight (pounds)

Page 27 of the Desa Tech Gas Log Set (18) user manual — PARTS CENTRALS
Page 27 · click to enlarge
Page 27

REPLACEMENT

PARTS

Parts Under Warranty Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see below) or call DESA International’s Technical Service Department at 1-800-323-5190 for referral information.

When calling DESA International, have ready

  • your name
  • your address
  • model number of your heater
  • how heater was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date Usually, we will ask you to return the defective part to the factory.

Parts Not Under Warranty Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (see below) or call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

  • model number of your heater
  • the replacement part number

PARTS CENTRALS

These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.

Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department

Washer Equipment Co. 1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911

Halco Enterprises 208 Carter Drive, Unit 21 West Chester, PA 19382 215-696-2670 1-800-368-0803

East Coast Energy Products 833 Broadway W. Long Branch, NJ 07764 908-870-8809 1-800-755-8809

LA Porte's Parts & Service 2444 N. 5th Street Hartsville, SC 29550 803-332-0191 Parts Department

Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687 All States 803-879-3009 1-800-845-5301

Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724

FBD P.O. Box 1096 1720 Kummer Road Franklin, KY 42134 502-586-1922 1-800-654-8534

Albany Ladder 1586-90 Central Avenue Albany, NY 12205 NY, MA, VT 518-869-5335 1-800-354-7368

Four Flags Power Products 1115 Stateline Road Niles, MI 49120 616-684-2697 Parts Only

Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426

Master Service Center 1184 Wilson NW Walker, MI 49504 616-791-4760 1-800-446-1446

Page 28 of the Desa Tech Gas Log Set (18) user manual — REPLACEMENT
Page 28 · click to enlarge
Page 28
Desa Tech Gas Log Set (18) — REPLACEMENT diagram (page 28)
Fig. 1
Page 29 of the Desa Tech Gas Log Set (18) user manual — PARTS AVAILABLE — NOT SHOWN
Page 29 · click to enlarge
Page 29

PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 27 of this manual.

PART NUMBER FOR KEY 18,000 Btu/Hr 28,000 Btu/Hr NO. CGN18TB CGN28TB DESCRIPTION QTY.

1 098304-01 098304-01 Screw, #10 x 3/8" 2 2 098742-03 098742-04 Front Panel (Comfort Glow) 1 098742-07 098742-08 Front Panel (Touch’n Glow) 1 3 098197-01 098197-02 Grill Guard 1 4 098342-01 098342-01 Clip, Grill Guard 2 5 098533-01AA 098533-02AA Bottom Glass Retainer 1 6 098260-01 098260-02 Glass Panel 1 7 098532-01AA 098532-02AA Top Glass Retainer 1 8 M11084-26 M11084-26 Screw, #10 x 3/8" 4 9 098352-01BR 098352-02BR Deflector Unit 1 10 098271-02 098271-02 Ignitor Cable 1 11 098249-01 098249-01 Nut, M5 2 12 099440-05 099440-05 ODS/Pilot Assembly 1 12-1 098514-01 098514-01 Thermocouple 1 12-2 098515-01 098515-01 Ignitor Electrode 1 13 099120-02 099126-02 Burner 1 14 098517-01 098517-01 3/16" Pilot Tubing 1 15 098251-02 098251-04 Injector 1 16 098250-01 098250-01 Injector Holder 1 17 098867-04 098867-04 Pressure Regulator 1 18 099553-01 099553-01 Pilot Shield 1 19 098518-01 098518-01 3/8" Outlet (Burner) Tubing 1 20 098297-03 098297-03 3/8" Inlet Tubing 1 21 098264-02 098264-02 3/8" NPT Male Connector 1 22 098276-01 098276-01 1/8" NPT Plug 1 23 098277-01 098277-01 3/8" to 1/8" NPT Bushing 1 24 098265-01 098265-01 3/8" NPT Male Elbow 1 25 098275-01 098275-01 3/8" NPT Plug 1 26 098522-03 098522-04 Thermostat Gas Valve 1 27 098530-01 098531-01 Cabinet 1 28 102445-01 102445-01 Piezo Ignitor 1 29 M11084-26 M11084-26 Screw, #10 x 3/8" 2 30 M11084-38 M11084-38 Screw, #8 x 3/8" 2 31 099066-01 099066-01 Mounting Bracket 1

PARTS AVAILABLE — NOT SHOWN

098305-01 098305-01 Control Position Label 1 100642-01 100642-01 Hardware Assembly 1

Page 30 of the Desa Tech Gas Log Set (18) user manual — PARTS AVAILABLE — NOT SHOWN
Page 30 · click to enlarge
Page 30

ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, either contact your nearest Parts Central (see page 27) or call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the address listed on the back page of this manual.

FAN KITS - GA2100A, GA3100, GA3100A, and GA3200TA For all models. Provides better heat distribu- tion. Makes heater more efficient. Complete installation and operating instructions included. Manually controlled - GA2100A, GA3100, and GA3100A. Includes ON/OFF switch. Thermostatically controlled - GA3200TA. Includes three settings: ON/OFF/AUTO.

FLOOR MOUNTING STAND 18,000 Btu/Hr Models - GA4000B and GA4500 28,000 Btu/Hr Model - GA4010B and GA4510 For locating heater on the floor, away from a wall. Complete installation instructions included.

MANUAL SHUTOFF VALVE - GA5010 For all models. Manual shutoff valve with 1/8" NPT tap.

Page 31 of the Desa Tech Gas Log Set (18) user manual — NOTES _________________________________________________________________
Page 31 · click to enlarge
Page 31

NOTES

Show 38 more labels / short text on this page
_________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________ · _________________________________________________________________
Page 32 of the Desa Tech Gas Log Set (18) user manual — 101808-01 REV. C 3/96
Page 32 · click to enlarge
Page 32

WARRANTY INFORMATION

KEEP THIS WARRANTY

Serial No.

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY COMFORT GLOW VENT-FREE NATURAL GAS HEATERS

DESA International warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE (1) YEAR FROM THE DATE OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004

101808-01 REV. C 3/96

Model · Date Purchased

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
2 p.2
2 p.2
18 p.18
18 p.18
22 p.22
22 p.22
24 p.24
24 p.24
26 p.26
26 p.26

Ask about the Desa Tech Gas Log Set (18)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa Tech Gas Log Set (18)

Be the first to ask — other owners or our team will answer.

Original document

Desa Tech Gas Log Set (18) manual PDF

32 pages·358 KB·Gas Heater·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…