Table of Contents 60 sections UNVENTED (VENT-FREE) GAS LOG HEATER OWNER’S OPERATION AND INSTALLATION MANUAL · 18", 24" AND 30" REMOTE READY (Yellow Flame Model Shown) · CCL3018NR, CCL3018PR CCL3018NRA, CCL3018PRA CCL3924NR, CCL3924PR CCL3924NRA, CCL3924PRA · CHL3924NR, CHL3924PR CCL3930NR, CCL3930PR CCL3930NRA, CCL3930PRA · … ShowHide
UNVENTED (VENT-FREE) GAS LOG HEATER OWNER’S OPERATION AND INSTALLATION MANUALp.118", 24" AND 30" REMOTE READY (Yellow Flame Model Shown)p.1CCL3018NR, CCL3018PR CCL3018NRA, CCL3018PRA CCL3924NR, CCL3924PR CCL3924NRA, CCL3924PRAp.1CHL3924NR, CHL3924PR CCL3930NR, CCL3930PR CCL3930NRA, CCL3930PRAp.1— Do not store or use gasoline or other flammablep.1TABLE OF CONTENTSp.2SAFETY INFORMATIONp.3DANGER: Carbon monoxide poisoning may lead to death!p.3PRODUCT IDENTIFICATIONp.5REMOTE CONTROLp.5ACCESSORIESp.5AIR FOR COMBUSTIONp.5UNPACKINGp.5AND VENTILATIONp.5PRODUCT FEATURESp.5DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONp.6VENTILATION AIRp.7INSTALLATION AND CLEARANCES (Vent-Free Operation Only)p.9MINIMUM FIREPLACE CLEARANCEp.9TO COMBUSTIBLE MATERIALSp.9(A)p.10INSTALLING HEATER BASE ASSEMBLYp.12Continued CONNECTING TO GAS SUPPLYp.13CHECKING GAS CONNECTIONSp.14PRESSURE TESTING GAS SUPPLY PIPING SYSTEMp.14O POSIp.15POp.15Continued INSTALLING LOGSp.17AUTO OFF ONp.17OPERATING HEATERp.19LIGHTING INSTRUCTIONSp.19FOR YOUR SAFETY READ BEFORE LIGHTINGp.19TO TURN OFF GASp.20TO APPLIANCEp.20REMOTE OFF ONp.20MANUAL LIGHTINGp.21OPTIONAL HAND-HELDp.21ON OFF REMOTEp.21INSPECTING BURNERSp.22CLEANING ANDp.23MAINTENANCEp.23TROUBLESHOOTINGp.24OBSERVED PROBLEMp.24POSSIBLE CAUSEp.24REMEDYp.24PARTS LISTp.29KEY PART NUMBERp.29NO. CCL3018PR CCL3018PRA CCL3018NR CCL3018NRA DESCRIPTION QTYp.29PARTS AVAILABLE — NOT SHOWNp.29SPECIFICATIONSp.32WIRING DIAGRAMp.32TECHNICAL SERVICEp.32TPTH TPp.32SERVICE HINTSp.32REPLACEMENT PARTSp.33PARTS CENTRALp.33NOTESp.35WARRANTY INFORMATIONp.36KEEP THIS WARRANTYp.36LIMITED WARRANTY COMFORT GLOW VENT-FREE GAS LOG HEATERSp.36
Page 1 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — — Do not store or use gasoline or other flammable
Page 1 · click to enlarge
Page 1

UNVENTED (VENT-FREE) GAS LOG HEATER OWNER’S OPERATION AND INSTALLATION MANUAL

Desa Tech Direct Vent Fireplace (CCL3930PRA) — UNVENTED (VENT-FREE) GAS LOG HEATER OWNER’S OPERATION AND INSTALLATION MANUAL diagram (page 1)
Fig. 1

18", 24" AND 30" REMOTE READY (Yellow Flame Model Shown)

CCL3018NR, CCL3018PR CCL3018NRA, CCL3018PRA CCL3924NR, CCL3924PR CCL3924NRA, CCL3924PRA

CHL3924NR, CHL3924PR CCL3930NR, CCL3930PR CCL3930NRA, CCL3930PRA

Also Design-Certified As Vented Decorative Appliances When

Not Used With Hand-Held Thermostat Remote

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a quali-

fied installer, service agency, or the gas supplier.

Save this manual for future reference. For more information, visit www.desatech.com

Page 2 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — Table of Contents
Page 2 · Contents
Contents

Contents

UNVENTED (VENT-FREE) GAS LOG HEATER OWNER’S OPERATION AND INSTALLATION MANUALp.118", 24" AND 30" REMOTE READY (Yellow Flame Model Shown)p.1CCL3018NR, CCL3018PR CCL3018NRA, CCL3018PRA CCL3924NR, CCL3924PR CCL3924NRA, CCL3924PRAp.1CHL3924NR, CHL3924PR CCL3930NR, CCL3930PR CCL3930NRA, CCL3930PRAp.1— Do not store or use gasoline or other flammablep.1TABLE OF CONTENTSp.2SAFETY INFORMATIONp.3DANGER: Carbon monoxide poisoning may lead to death!p.3PRODUCT IDENTIFICATIONp.5REMOTE CONTROLp.5ACCESSORIESp.5AIR FOR COMBUSTIONp.5UNPACKINGp.5AND VENTILATIONp.5PRODUCT FEATURESp.5DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONp.6VENTILATION AIRp.7INSTALLATION AND CLEARANCES (Vent-Free Operation Only)p.9MINIMUM FIREPLACE CLEARANCEp.9TO COMBUSTIBLE MATERIALSp.9(A)p.10INSTALLING HEATER BASE ASSEMBLYp.12Continued CONNECTING TO GAS SUPPLYp.13CHECKING GAS CONNECTIONSp.14PRESSURE TESTING GAS SUPPLY PIPING SYSTEMp.14O POSIp.15POp.15Continued INSTALLING LOGSp.17AUTO OFF ONp.17OPERATING HEATERp.19LIGHTING INSTRUCTIONSp.19FOR YOUR SAFETY READ BEFORE LIGHTINGp.19TO TURN OFF GASp.20TO APPLIANCEp.20REMOTE OFF ONp.20MANUAL LIGHTINGp.21OPTIONAL HAND-HELDp.21ON OFF REMOTEp.21INSPECTING BURNERSp.22CLEANING ANDp.23MAINTENANCEp.23TROUBLESHOOTINGp.24OBSERVED PROBLEMp.24POSSIBLE CAUSEp.24REMEDYp.24PARTS LISTp.29KEY PART NUMBERp.29NO. CCL3018PR CCL3018PRA CCL3018NR CCL3018NRA DESCRIPTION QTYp.29PARTS AVAILABLE — NOT SHOWNp.29SPECIFICATIONSp.32WIRING DIAGRAMp.32TECHNICAL SERVICEp.32TPTH TPp.32SERVICE HINTSp.32REPLACEMENT PARTSp.33PARTS CENTRALp.33NOTESp.35WARRANTY INFORMATIONp.36KEEP THIS WARRANTYp.36LIMITED WARRANTY COMFORT GLOW VENT-FREE GAS LOG HEATERSp.36
Page 3 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — DANGER: Carbon monoxide poisoning may lead to death!
Page 3 · click to enlarge
Page 3

SAFETY INFORMATION

Due to high temperatures, the appliance should be located out of traffic and away from furni- ture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

DANGER: Carbon monoxide poisoning may lead to death!

Heater base assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut- down. Allow surface to cool be- fore touching.

Carbon Monoxide Poisoning: Early signs of car- bon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Carefully supervise young chil- dren when they are in the room with heater. When using the hand-held remote accessory, keep selector switch in the OFF position to prevent children from turning on burners with remote.

Natural and Propane/LP Gas: Natural and propane/ LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warn- ings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

Keep the appliance area clear and free from combustible ma- terials, gasoline, and other flam- mable vapors and liquids.

1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).
Page 4 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — SAFETY INFORMATION
Page 4 · click to enlarge
Page 4

SAFETY INFORMATION

  • 12. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 5. If heater keeps shutting off, see Troubleshooting , page 24. 13. Do not run heater
  • where flammable liquids or vapors are used or stored
  • under dusty conditions 14. Do not use this heater to cook food or burn paper or other objects. 15. Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. 16. Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dimesized or larger). 17. Turn heater off and let cool before servicing, installing, or repairing. Make sure the remote selector switch is in the OFF position. Only a qualified service person should install, service, or repair heater. 18. Make sure the remote selector switch is in the OFF position when you are away from home for long periods of time. 19. This heater must not be connected to any external electrical source. 20. Operating heater above elevations of 4,500 feet may cause pilot outage. 21. Provide adequate clearances around air openings.
  • 3. To prevent performance problems, the use of a propane/LP fuel tank of less than 100 lb. capacity is not recommended (propane/LP units only). 4. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 5. This heater shall not be installed in a bedroom or bathroom unless installed as a vented appliance (see Installing Damper Clamp Accessory for Vented Operation, page 11). 6. Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes, and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue and firebox before operating heater. 7. Do not burn solid-fuel in a masonry or UL127 factory-built fireplace in which a vent-free room heater is installed. 8. If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across openings of fireplace. 9. This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking may occur due to log curing and heater burning manufacturing residues. 10. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 23. 11. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc.

1430 Broadway New York, NY 10018 National Fire Protection Association, Inc.

Batterymarch Park Quincy, MA 02269 Note: Where listed vented decorative logs are re- quired, thermostat operation is not permitted.

Page 5 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — PRODUCT FEATURES
Page 5 · click to enlarge
Page 5

PRODUCT IDENTIFICATION

SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/ pilot is a required feature for vent-free room heat- ers. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM This heater has a piezo ignitor. This system re- quires no matches, batteries, or other sources to light heater.

REMOTE CONTROL

ACCESSORIES

  • There are two optional remote controls that can be purchased separately for this log heater:
  • hand-held ON/OFF remote
  • hand-held thermostat remote See Accessories, page 34. The hand-held thermostat may not be used where vented decorative listing is required.

Figure 1 - Vent-Free Gas Log Heater

(Logs May Vary By Model)

AIR FOR COMBUSTION

UNPACKING

AND VENTILATION

1. Remove logs and heater base assembly from carton. Note: Do not pick up heater base assembly by burners. This could damage heater. Always handle base assembly by grate. 2. Remove all protective packaging applied to logs and heater for shipment. 3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought heater.

Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible. While it is good to make your home energy effi- cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation. Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

PRODUCT FEATURES

OPERATION This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic dancing, yellow flames. This heater is designed for vent- free operation with flue damper closed. It has been tested and approved to ANSI Z21.11.2 standard for unvented heaters. This heater may also be op- erated as a vented decorative (ANSI Z21.60) prod- uct by opening flue damper (non-thermostat mod- els only).

Show 7 more labels / short text on this page
Log Set · Optional Remote Control · Piezo Ignitor · Base Grate · Optional Selector Switch · Flame Adjustment Knob · Control Knob
Page 6 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Page 6 · click to enlarge
Page 6

AIR FOR COMBUSTION

Confined Space and Unconfined Space The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose vol- ume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an un- confined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all ap- pliances installed in that space. Rooms communi- cating directly with the space in which the appli- ances are installed*, through openings not fur- nished with doors, are considered a part of the unconfined space. * Adjoining rooms are communicating only if there are doorless passageways or ventilation grills be- tween them.

AND VENTILATION

Continued PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three fol- lowing ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 5 through 7 will help you classify your space and provide adequate ven- tilation.

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ven- tilation. However, in buildings of unusually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the out- side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to ar- eas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, be- tween wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 7. If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Heater Location.

Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will in- stall heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = cu. ft. (volume of space) Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (vol- ume of space) If additional ventilation to adjoining room is sup- plied with grills or openings, add the volume of these rooms to the total volume of the space. 2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.

(volume of space) x 20 = (Maxi- mum Btu/Hr the space can support) Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support) 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free fireplace Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr

Page 7 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — VENTILATION AIR
Page 7 · click to enlarge
Page 7

AIR FOR COMBUSTION

VENTILATION AIR

AND VENTILATION

Ventilation Air From Inside Building This fresh air would come from an adjoining un- confined space. When ventilating to an adjoining unconfined space, you must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

* Do not include direct-vent gas appliances. Di- rect-vent draws combustion air from the outdoors and vents to the outdoors. Example: Gas water heater Btu/Hr Vent-free fireplace + Btu/Hr Total = Btu/Hr 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

Btu/Hr (maximum the space can support) Btu/Hr (actual amount of Btu/Hr used) Example: 51,200 Btu/Hr (maximum the space

can support) 79,000 Btu/Hr (actual amount of Btu/Hr used) The space in the above example is a confined space because the actual Btu/Hr used is more than the maxi- mum Btu/Hr the space can support. You must pro- vide additional fresh air. Your options are as follows: A. Rework worksheet, adding the space of an adjoin- ing room. If the extra space provides an uncon- fined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building. B. Vent room directly to the outdoors. See Ventila- tion Air From Outdoors. C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined. If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an uncon- fined space. You will need no additional fresh air ven- tilation.

Ventilation Grills Into Adjoining Room,

Or Remove Door into Adjoining

Figure 2 - Ventilation Air from Inside

Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent open- ings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts. IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-con- trolled power vent. Heated air entering the attic will activate the power vent.

Inlet Air Ventilated Crawl Space

Figure 3 - Ventilation Air from Outdoors

Show 15 more labels / short text on this page
40,000 39,000 79,000 · 12" · Ventilation · Grills Into Adjoining · Room, Option 1 · Option 2 · Room, Option · 12" · Building · Outlet Air · Ventilated Attic · Outlet Air · To Attic · To Crawl Space · Inlet Air
Page 8 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — VENTILATION AIR
Page 8 · click to enlarge
Page 8

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

  • WARNING: Never install the heater
  • in a bedroom or bathroom unless installed as a vented appliance, see page 11.
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater
  • in high traffic areas
  • in windy or drafty areas

CHECK GAS TYPE Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.

Page 9 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — MINIMUM FIREPLACE CLEARANCE
Page 9 · click to enlarge
Page 9

INSTALLATION AND CLEARANCES (Vent-Free Operation Only)

*Minimum 16 inches from Side Wall

Figure 4 - Minimum Clearance for

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Side Wall 16" Ceiling42"
LOG SIZING REQUIREMENTS Log SizeMinimum Firebox HeightDepthFront WidthRear * Width 18" 24" 30"17" 17" 17"13" 13" 13"28" 28" 34"20" 21" 24"

Minimum Noncombustible Material Clearances

If Not Using Mantel Note: If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information below. You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombus- tible material behind it. Noncombustible material must extend at least 8" up (for all models). If non- combustible material is less than 12", you must in- stall the fireplace hood accessory (24" and 30" mod- els only). See Figure 5 for minimum clearances. IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chim- ney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 11.

Minimum Clearances for Side Combustible Material, Side Wall, and Ceiling A. Clearances from the side of the fireplace cabi-

net to any combustible material and wall should follow diagram in Figure 4. Example: The face of a mantel, bookshelf, etc. is made of combustible material and pro- trudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fire- place opening (see Figure 4). Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturer’s instructions for minimum clearances to combustible materials. B. Clearances from the top of the fireplace open-

ing to the ceiling should not be less than 42 inches.

Example · * · Combustible to Wall

Page 10 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — (A)
Page 10 · click to enlarge
Page 10

MANTEL CLEARANCES In addition to meeting noncombustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clearances listed below, you will need a hood.

If Using Mantel You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non- combustible material behind it. Noncombustible material must extend at least 8 inches up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7 on page 9 for minimum clearances. IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chim- ney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 11.

Determining Minimum Mantel Clearances If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

Determining Minimum Mantel Clearances When Using a Hood If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances re- quired. Follow minimum clearances shown in Fig- ure 7, page 11, when using hood.

Noncombustible Material Distance (A)Requirements for Safe Installation 12" or more Between 8" and 12" Less than 8"Noncombustible material okay. Install fireplace hood accessory (GA6050, GA6052, or GA6053 see Accessories, page 34). Noncombustible material must be extended to at least 8". See Between 8" and 12", above. If you cannot extend material, you must operate heater with flue damper open.

Underside of Mantel Shelf

2 1/2"

All minimum distances are in inches

(A)

Log Set 24"/30" Models

(A)

Top of Fireplace Opening

Minimum Noncombustible Material Height

Distances to Underside of Mantel

Figure 6 - Minimum Mantel Clearances

Figure 5 - Heat Resistant Material (Slate,

Marble, Tile, etc.) Above Fireplace

Show 18 more labels / short text on this page
10" · Mantel Shelf · 8" · 6" · Minimum Noncombustible Material · Heat Resistant Material · 12" · 18" · 20" · 22" · 24" · 8" · 8" · 14" · 17" · 20" · 18" Model · Without Using Hood
Page 11 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — (A)
Page 11 · click to enlarge
Page 11
  • NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:
  • operate the logs only with the flue damper open
  • raise the mantel to an acceptable height
  • remove the mantel.

5" Min.

Figure 9 - Minimum Fireplace Clearances

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note: When used as a vented heater, appliance must be installed only in a solid-fuel burning fire- place with a working flue and constructed of non- combustible material. If you choose to use your heater as a manually- controlled model (no remote control installed), you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode. 1. The fireplace does not meet the clearance to combustibles requirements for vent-free op- eration. 2. State or local codes do not permit vent-free operation. 3. You prefer vented operation. If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 34). This will insure vented operation (see Figure 10, page 12). The damper clamp will keep damper open. Installation instruc- tions are included with clamp accessory. See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Underside of Mantel Shelf

2 1/2"

All minimum distances are in inches

Minimum Noncombustible Material 8" Min.

Log Set 18", 24", 30" Models 20"

Top of Fireplace Opening

Distances to Underside of Mantel

Figure 7 - Minimum Mantel Clearances

FLOOR CLEARANCES A. If installing appliance on the floor level, you

must maintain the minimum distance of 14" to combustibles (see Figure 8). B. If combustible materials are less than 14" to

the fireplace, you must install appliance at least 5" above the combustible flooring (see Figure 9).

Chimney Height (ft.)Minimum Permanent Flue Opening (sq. in.) 6' to 15' 15' to 30'39 sq. inches 29 sq. inches
Area of Various Standard Round Flues Diameter (inches)Area (sq. inches) 5 6 7 820 29 39 51

14" Min.

Figure 8 - Minimum Fireplace Clearances

If Installed at Floor Level

Show 14 more labels / short text on this page
Hearth · Combustible Material · Above Combustible Flooring · Mantel Shelf · 12" · 10" · 8" · 6" · All Models · 12" 15" 18" · Hood (GA6050, GA6052) · When Using Hood · Combustible Material · Noncombustible Material
Page 12 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — INSTALLING HEATER BASE ASSEMBLY
Page 12 · click to enlarge
Page 12
  • Installation Items Needed
  • hardware package (provided with heater)
  • approved flexible gas hose (not provided) (if allowed by local codes)
  • sealant resistant to propane/LP gas, not provided
  • electric drill with 3/16" masonry drill bit Note: Install optional remote receiver and handheld remote kit (see Accessories , page 34) before installing gas log heater. See installation instructions included with the kit. 1. Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 11). 2. Locate masonry screws in hardware package. 3. Position heater base assembly in fireplace. 4. Place logs in their proper positions on heater base. 5. Center heater base and logs front-to-back and side-to-side in fireplace. 6. Carefully remove logs without moving heater base. 7. Mark screw locations through holes in mounting flanges (see Figure 12). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks. 8. Remove heater base from fireplace. 9. Drill holes at marked locations using 3/16" masonry drill bit. 10. Attach base assembly to fireplace floor using two masonry screws (in hardware package) (see Figure 12). 11. Connect to gas supply. See Connecting To Gas Supply, page 13.

Manufactured Fireplace Masonry Fireplace

Figure 10 - Attaching Damper Clamp

INSTALLING HEATER BASE ASSEMBLY

Flexible Gas Hose (if allowed by local codes) Fitting

Figure 11 - Attaching Flexible Gas Hose

Figure 12 - Attaching Base Assembly to

Show 9 more labels / short text on this page
Damper Clamp · Damper · Damper Clamp · Damper · Damper · to Heater · Masonry Screw · Mounting Flanges · Fireplace Floor
Page 13 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — Continued CONNECTING TO GAS SUPPLY
Page 13 · click to enlarge
Page 13

For propane/LP units, the installer must supply an external regulator. The external regulator will re- duce incoming gas pressure. You must reduce in- coming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down pro- tects it from freezing rain or sleet.

Continued CONNECTING TO GAS SUPPLY

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 14, page 14). IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Check your building codes for any special require- ments for locating equipment shutoff valve to fire- places. Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from go- ing into pipe. Excess sealant in pipe could result in clogged heater valves.

  • Installation Items Needed Before installing heater, make sure you have the items listed below.
  • piping (check local codes)
  • sealant (resistant to propane/LP gas)
  • equipment shutoff valve *
  • test gauge connection *
  • sediment trap
  • tee joint
  • pipe wrench * A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories , page 34.

Figure 13 - External Regulator With Vent

Show 4 more labels / short text on this page
Propane/LP Supply Tank · External Regulator · Vent Pointing Down · Pointing Down
Page 14 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Page 14 · click to enlarge
Page 14

CHECKING GAS CONNECTIONS

We recommend that you install a sediment trap in supply line as shown in Figure 14. Locate sedi- ment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped mat- ter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

PROPANE/LP From External Regulator (11" W.C.** to 14" W.C. Pressure) NATURAL From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)

CSA Design- Certified Equipment Shutoff Valve With 1/8" NPT Tap*

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equip- ment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve lo- cated on or near gas meter for natural gas, or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Approved Flexible Gas Hose (if allowed by local codes)

Cap Pipe Tee Nipple Joint

Figure 14 - Gas Connection

* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 34. ** Minimum inlet pressure for purpose of input adjustment.

3" Minimum · Gas Control · Sediment Trap

Page 15 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — O POSI
Page 15 · click to enlarge
Page 15

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 15). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve lo- cated on or near gas meter for natural gas, or using compressed air. 3. Check all joints from propane/LP supply tank to equipment shutoff valve for propane/LP gas (see Figure 16) or from gas meter to equip- ment shutoff valve for natural gas (see Figure 17). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Thermostat Gas Valve or Control Valve Location

Figure 16 - Checking Gas Joints

PRESSURE TESTING HEATER GAS CONNECTIONS 1. Open equipment shutoff valve (see Figure 15). 2. Open propane/LP supply tank valve or main gas valve located on or near gas meter for natural gas. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from propane/LP supply tank to equipment shutoff valve for propane/LP gas (see Figure 16) or from gas meter to equip- ment shutoff valve for natural gas (see Figure 17). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light heater (see Operating Heater, page 19). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appli- ance, page 20).

Thermostat Gas Valve or Control Valve Location

Figure 17 - Checking Gas Joints

INSTALLING REMOTE RECEIVER UNIT 1. Disconnect switch wires from the control valve. 2. Remove phillips head screws and heat shield. 3. Remove switch plate (see Figure 18). Discard after removing.

O POSI

PO

Figure 15 - Equipment Shutoff Valve

Figure 18 - Switch Plate and Wiring Harness (Switch Plate and Orientation

May Vary Depending On Model)

Show 11 more labels / short text on this page
Propane/LP Tank · Equipment Shutoff Valve · Equipment Shutoff Valve · Gas Meter · Equipment Shutoff Valve · Open · Front · Screws · Back · Closed · Wires
Page 16 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — O POSI
Page 16 · click to enlarge
Page 16
4. Install remote receiver unit onto gas log heater base using phillips head screws (see Figure 19). 5. Connect wires as shown in Figure 20.

Figure 21 - Installing Receiver on the

Back of the Base

Installing 9-Volt Battery (Not Included) in Hand-Held Remote Control Unit 1. Remove battery cover on back of remote con- trol unit. 2. Attach terminal wires to the battery. Place battery into the battery housing. 3. Replace battery cover onto remote control unit.

Figure 19 - Installing Remote Receiver

White Wire From Receiver

Red Wire From Receiver

Remote Control Unit Battery Housing

Figure 20 - Connecting Wires

INSTALLING WIRELESS HAND- HELD REMOTE CONTROL ACCESSORY Two 9-volt alkaline batteries (not included) are required to operate this heater with the wireless hand-held remote control set. One battery must be installed in the receiver and one in the hand- held remote control unit. Note: Only use alkaline batteries.

Figure 22 - Installing Battery in Hand-

Held Remote Control Unit (CGHRCB

Installing 9-Volt Battery in Receiver 1. Locate back of receiver under front burner of heater. 2. Locate the battery clip mounted on the back of the receiver. 3. Slide a 9-volt battery through the clip. 4. Attach the terminal wires to the battery.

Figure 23 - Installing Battery in Hand- Held Remote Control Unit (CGHRCTB

Show 15 more labels / short text on this page
Receiver · Terminal Wires · 9-Volt Battery · Battery Clip · Front · Screws · Back · Remote Receiver · Terminal Wires · Battery Cover · Valve · 9-Volt Battery · Series) · Remote Control Unit · Series)
Page 17 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — AUTO OFF ON
Page 17 · click to enlarge
Page 17

Continued INSTALLING LOGS

AUTO OFF ON

Figure 24 - Installing Front Log (#1)

Each log is marked with a number. These num- bers will help you identify the log when install- ing. It is very important to install these logs ex- actly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Place the front log (#1) on the grate fingers. Make sure the front log rests firmly between the grate fingers and the grate base (see Fig- ure 24). 2. Place the base of the middle log (#2) in the U- shaped slots of the grate base. The cutout on the right of the middle log should fit over the burner (see Figure 25). Make sure the front of the middle log is resting on the tabs of the grate base. 3. Locate pegs on the bottom of back log (#3). Slide these pegs into the holes in the grate base behind the burner (see Figure 26). 4. Locate pegs on the bottom of crossover log (#4). Slide these pegs into the holes located in middle log (#2) and back log (#3). See Fig- ure 27, page 18, for placement.

AUTO OFF ON

Figure 25 - Installing Middle Log (#2)

Hole in Grate Base

AUTO OFF ON

Figure 26 - Installing Rear Log (#3)

Show 12 more labels / short text on this page
Front Log (#1) · Grate Fingers · Grate Base · (CCL3930PR/NR Shown) · Middle Log (#2) · Burner · Tab · U-Shaped Slot · (CCL3930PR/NR Shown) · Pegs · Burner · (CCL3930PR/NR Shown)
Page 18 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — AUTO OFF ON
Page 18 · click to enlarge
Page 18
5. Locate pegs on the bottom of crossover log (#5). Slide these pegs into the holes located in crossover log (#4) and front log (#1). See Figure 28.

For CCL3018PR/NR Only: Locate holes on the bottom of crossover log (#5). Slide the holes over the left pegs on middle log (#2) and front log (#1). See Figure 29. 6. Locate pegs on the bottom of crossover log (#6). Slide these pegs into the holes located in middle log (#2) and front log (#1). See Fig- ure 30. 7. For CCL3930PR/NR only, locate holes on the bottom of crossover log (#7). Slide onto the pegs located in crossover log (#6) and middle log (#2). See Figure 31. 8. Add lava rock around base of heater if desired. Do not place any lava rock on logs or burner.

Figure 29 - Installing Crossover Log (#5) (CCL3018PR/PRA and CCL3018NR/NRA Only)

AUTO OFF ON

Figure 30 - Installing Crossover Log (#6)

AUTO OFF ON

Figure 27 - Installing Crossover Log (#4)

AUTO OFF ON

Figure 31 - Installing Crossover Log (#7)

AUTO OFF ON

to Models CCL3930PR/PRA and

Figure 28 - Installing Crossover Log (#5)

Show 18 more labels / short text on this page
Crossover Log (#4) · Front Log (#1) · Pegs · Pegs · Log #2 · Log #2 · Log #3 · Front Log (#1) · (CCL3930PR/NR Shown) · Holes · Crossover Log (#6) · (CCL3930PR/NR Shown) · Crossover Log (#4) · Pegs · Middle Log (#2) · Front Log (#1) · CCL3930NR/NRA Only · (CCL3930PR/NR Shown)
Page 19 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — LIGHTING INSTRUCTIONS
Page 19 · click to enlarge
Page 19

OPERATING HEATER

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

  • WARNING:
  • If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across opening of fireplace.
  • You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

A. This appliance has a pilot which must be

lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the

  • appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the

Note: Home owners generally prefer to oper- ate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has

been under water. Immediately call a quali- fied service technician to inspect the appli- ance and to replace any part of the control system and any gas control which has been under water.

1. STOP! Read the safety information, column 1. 2. Make sure equipment shutoff valve is fully open. 3. Set selector switch in the OFF position.
Page 20 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — REMOTE OFF ON
Page 20 · click to enlarge
Page 20

OPERATING HEATER

4. Press in and turn control knob clockwise

to the OFF position (see Figure 32). 5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 19. If you don’t smell gas, go to the next step. 6. Press in and turn control knob counter- clockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 32). Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. 7. With control knob pressed in, press and re- lease ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 21. 8. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when re- leased, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8. 9. Slightly push in and turn control knob counterclockwise to the ON position. 10. Wait one minute and switch selector switch to the ON position to light burners. 11. Set flame adjustment knob to any level be- tween HI and LO.

Ignitor Electrode Pilot Burner

Ignitor Electrode Pilot Burner

Figure 33 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater 1. Turn control knob clockwise to the OFF position. 2a. Set selector switch in the OFF position. 2b. If Using Optional Hand-Held remote: Set se- lector switch in the OFF position to keep from draining battery.

Shutting Off Burners Only (pilot stays lit) You may shut off the burners and keep the pi- lot lit by doing one of the following: 1. Turn control knob clockwise to the PILOT position. 2. Use remote control manual OFF button. 3. Set selector switch in the OFF position.

REMOTE OFF ON

H

N

O

O

F

F

O

T

O

P

Selector Switch in OFF Position

Figure 32 - Control Knob and Ignitor

Show 6 more labels / short text on this page
Propane/LP Gas · Natural Gas · Flame Adjustment Knob · Control Knob · Ignitor Button · Button Location
Page 21 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — ON OFF REMOTE
Page 21 · click to enlarge
Page 21

OPERATING HEATER

ON/OFF SERIES (MODEL CGHRCB) Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 35). TO LOCK press both buttons on hand-held re- mote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed. TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now un- locked.

MANUAL LIGHTING

PROCEDURE 1. Follow steps 1 through 6 under Lighting In- structions, pages 19 and 20. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions, page 20.

OPTIONAL HAND-HELD

REMOTE OPERATION Note: CGHRCTB Hand-Held Remote Control Kit is included with CHL3924NR/PR models only. Hand-held remote control accessories must be purchased separately for all other models (see Accessories, page 34). Follow in- structions included with the remote control.

Control Button Turns Burners On and Off

Figure 35 - On/Off Hand-Held Remote

THERMOSTAT SERIES (MODEL CGHRCTB) The hand-held remote can be operated using either the manual mode (MANU) or thermo- static mode (AUTO) (see Figure 36). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Ad- just flame adjustment knob anywhere between HI and LO. Slide the selector switch to the RE- MOTE position (see Figure 34). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand- held remote control unit. IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

Turns Hand- Held Remote On or Off and Allows You to Choose the Manual Setting

Digital Display Shows Temperature and Settings

Turns Burners On or Off

Control Knob Flame Adjustment Knob

Decreases Room Temperature in AUTO Mode

H

Increases Room Temperature in AUTO Mode

ON OFF REMOTE

O

F

F

P

O

T

O

N

O

Locks System to Prevent Accidental Ignition

Selector Switch in Remote Position

Figure 34 - Setting the Selector Switch,

Control Knob, and Flame Adjustment

Figure 36 - Thermostat Hand-Held

Knob for Remote Operation

Remote Control Unit (GHRCTB)

Control Unit (CGHRCB) · Selects Auto Setting

Page 22 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — INSPECTING BURNERS
Page 22 · click to enlarge
Page 22

OPERATING HEATER

Key Pad Lock Feature This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent opera- tion (i.e. children operating the hand-held re- mote control, etc.). The keypad is locked in ei- ther on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

Manual Mode 1. Press the POWER and LOCK buttons to- gether to turn on the hand-held remote control. 2. Press the MANU button to turn on the fire- place. 3. Press the POWER and LOCK buttons to- gether to turn off the fireplace.

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat- terns often.

Auto (Thermostatic) Mode 1. Press the POWER and LOCK buttons to- gether to turn on the hand-held remote control. 2. Press AUTO button to select this mode. 3. Set the desired room temperature by press- ing the TEMP + or - buttons. 4. Press the POWER and LOCK buttons to- gether to turn off the fireplace Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fire- place. Ideally, place the hand-held remote in the center of the room facing towards the fireplace. Note: Do not hold the hand-held remote for a long time. Body temperature will affect its op- eration in the AUTO mode.

  • PILOT FLAME PATTERN Figure 37 shows a correct pilot flame pattern. Figure 38, shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. When the thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 38
  • turn heater off (see To Turn Off Gas to Appliance , page 20)
  • see Troubleshooting , page 24 Note: The pilot flame on natural gas units will have a slight curve, but the flame should be blue and have no yellow or orange color.

Natural Gas Propane/LP Gas

Safety Features When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Figure 37 - Correct Pilot Flame Pattern

Auto Shutoff Feature 1. If the average room temperature exceeds 82 degrees Fahrenheit (28 degrees Centi- grade), the hand-held remote control will perform a safety override and shut the fire- place off. This feature is not available in the MANU mode. 2. The receiver continuously receives signals from the hand-held remote to control the room temperature. If the hand-held remote is misplaced, obstructed, or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Natural Gas Propane/LP Gas

Figure 38 - Incorrect Pilot Flame Pattern

Show 5 more labels / short text on this page
Pilot Burner · Thermocouple · Pilot Burner · Pilot Burner · Thermocouple
Page 23 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — MAINTENANCE
Page 23 · click to enlarge
Page 23

CLEANING AND

particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the in- jector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4. Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot as- sembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 40). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if com- pressed air is not available.

MAINTENANCE

Burner Tube Injector Holder

Primary Air Inlet Holes

Figure 39 - Injector Holder On Outlet

BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater in- spected yearly by a qualified service person. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using com- pressed air no greater than 30 PSI. Your local com- puter store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 39). 3. Blow air through the ports/slots and holes in the burner. 4. Check the injector holder located at the end of the burner tube again. Remove any large

Pilot Air Inlet Hole

Figure 40 - Pilot Inlet Air Hole

  • LOGS
  • If you remove logs for cleaning, refer to Installing Logs, page 17, to properly replace logs.
  • Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.

Show 4 more labels / short text on this page
Burner Tube · Ports/Slots · Burner Tube · Pilot Assembly
Page 24 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — OBSERVED PROBLEM
Page 24 · click to enlarge
Page 24

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1. Ignitor electrode not connected to ignitor cable 2. Ignitor cable pinched or wet
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 3. Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel 4. Replace ignitor cable 5. Replace piezo ignitor 6. Replace pilot assembly
3. Piezo ignitor nut is loose
4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode positioned wrong 7. Ignitor electrode broken
7. Replace pilot assembly

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or equipment shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open equipment shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Contact local propane/LP gas company 6. Clean ODS/pilot (see Cleaning and Maintenance , page 23) or replace ODS/pilot assembly 7. Replace gas regulator
5. Depleted gas supply (propane/ LP only) 6. ODS/pilot is clogged
7. Gas regulator setting is not correct
Page 25 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — OBSERVED PROBLEM
Page 25 · click to enlarge
Page 25

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

ODS/pilot lights but flame goes out when control knob is re- leased

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 30 seconds 3. Fully open equipment shutoff valve 4. A) Contact local natural or propane/LP gas company B) Clean ODS/pilot (see Cleaning and Maintenance , page 23) or replace ODS/pilot assembly
3. Equipment shutoff valve not fully open 4. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot 5. Thermocouple connection loose at control valve 6. Thermocouple damaged 7. Control valve damaged
5. Hand tighten until snug, then tighten 1/4 turn more 6. Replace pilot assembly 7. Replace control valve

Burner does light after ODS/ pilot is lit

1. Burner orifice clogged
1. Clean burner (see Cleaning and Maintenance , page 23) or replace burner orifice 2. Contact local natural or propane/LP gas company 3. Reconnect leads (see Wiring Diagram , page 32)
2. Inlet gas pressure is too low
3. Thermopile leads disconnected or improperly connected 4. Burners will not come on in remote position
4. Replace battery in transmitter and receiver
1. Manifold pressure is too low
1. Contact local natural or propane/LP gas company 2. Clean burner (see Cleaning and Maintenance , page 23) or replace burner orifice
2. Burner orifice clogged

Burner backfiring during com- bustion

1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Maintenance , page 23) or replace burner orifice 2. Replace damaged burner 3. Replace gas control
2. Damaged burner 3. Gas regulator defective

Delayed ignition burner

Page 26 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — OBSERVED PROBLEM
Page 26 · click to enlarge
Page 26

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Slight smoke or odor during ini- tial operation

1. Not enough air
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance , page 23) 2. Replace gas control 3. Problem will stop after a few hours of operation
2. Gas regulator defective 3. Residues from manufacturing processes and logs curing

Moisture/condensation noticed on windows

1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and Ventilation requirements (page 5)

Heater produces a whistling noise when burner is lit

1. Turning control knob to HI position when burner is cold 2. Air in gas line
1. Turn control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local natural or propane/LP gas company 3. Observe minimum installation clearances (see page 9) 4. Clean burner (see Cleaning and Maintenance , page 23) or replace burner orifice
3. Air passageways on heater blocked 4. Dirty or partially clogged burner orifice

White powder residue forming within burner box or on adja- cent walls or furniture

1. When heated, vapors from furniture polish, wax, carpet cleaners, etc. may turn into white powder residue
1. Turn heater off when using furniture polish, wax, carpet cleaners or similar products

Remote does not function

1. Battery is not installed. Battery power is low
1. Replace 9-volt batteries in receiver and hand-held remote control

Heater produces a clicking/tick- ing noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most heaters. If noise is excessive, contact qualified service person
Page 27 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — OBSERVED PROBLEM
Page 27 · click to enlarge
Page 27

TROUBLESHOOTING

  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces unwanted odors

1. Heater burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See IMPORTANT statement above) 2. Gas leak. See Warning statement at top of page
1. Open window and ventilate room. Stop using odor causing products while heater is running
2. Locate and correct all leaks (see Checking Gas Connections , page 14)

Heater shuts off in use (ODS operates)

1. Not enough fresh air is available 2. Low line pressure
1. Open window and/or door for ventilation 2. Contact local natural or propane/LP gas company 3. Clean ODS/pilot (see Cleaning and Maintenance , page 23)
3. ODS/pilot is partially clogged

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at top of page
1. Locate and correct all leaks (see Checking Gas Connections , page 14) 2. Replace control valve
2. Control valve defective

Gas odor during combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections , page 14)
Page 28 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — TROUBLESHOOTING
Page 28 · click to enlarge
Page 28
Desa Tech Direct Vent Fireplace (CCL3930PRA) — TROUBLESHOOTING diagram (page 28)
Fig. 2
Page 29 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — PARTS AVAILABLE — NOT SHOWN
Page 29 · click to enlarge
Page 29

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual.

KEY PART NUMBER

NO. CCL3018PR CCL3018PRA CCL3018NR CCL3018NRA DESCRIPTION QTY

1 105958-04 111340-03 105958-04 111340-03 Front Log 1 2 105959-04 111341-03 105959-04 111341-03 Middle Log 1 3 105960-04 111342-03 105960-04 111342-03 Back Log 1 4 105961-04 111343-03 105961-04 111343-03 Left Back Crossover Log 1 5 105962-04 111344-02 105962-04 111344-02 Left Top Crossover Log 1 6 105963-04 111345-02 105963-04 111345-02 Right Bottom Crossover Log (#6) 1 7 103778-01 103778-01 103779-01 103779-01 ODS Pilot 1 8 098249-01 ODS Nut 2 9 111331-01 111331-01 104422-05 104422-05 Burner Outlet Tube 1 10 098264-02 Male Connector 1 11 111124-01 Burner Retainer Spring 1 12 099056-19 099056-19 099056-26 099056-26 Burner Orifice Injector 1 13 102445-01 Piezo Ignitor 1 14 102980-01 Burner 1 15 100609-01 100609-01 099387-13 099387-13 Pilot Tube 1 16 099918-02 099918-02 Pilot Regulator 1 17 099387-15 099387-15 Pilot Tube (Valve to regulator) 1 18 103345-02 Lower Bracket 1 19 103284-02 Wiring Harness 1 20 103781-01 103781-01 103781-02 103781-02 Gas Control Valve 1 21 104099-01 Heat Shield 1 22 103587-02 Plate, Switch 1 23 M11084-38 Screw, #8 x .38 4 24 M12461-26 Screw, Hex Slt Wsr 10-32 x .38 4 25 ** Painted Base Assy 1 26 103784-01 Off-Pilot-On Knob 1 27 103784-02 Flame Adjustment Knob 1 28 098304-01 Screw 2 29 099998-01 Switch 1 30 098271-10 Ignitor Cable 1

PARTS AVAILABLE — NOT SHOWN

100563-01 Warning Plate 1 103877-01 Lighting Instructions Plate 1 100565-01 Warning Plate Fastener 1 100639-01 Caution Decal 1 101137-02 Hardware Kit 1 GA6060 Lava Rock 1

** Not a field replaceable part.

Page 30 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — MODELS CCL3924PR, CCL3924PRA, CCL3924NR, CCL3924NRA, CCL3930PR, CCL3930PRA, CCL3930NR, CCL3930NRA, CHL3924NR, AND CHL3924PR
Page 30 · click to enlarge
Page 30
Desa Tech Direct Vent Fireplace (CCL3930PRA) — PARTS LIST diagram (page 30)
Fig. 3

MODELS CCL3924PR, CCL3924PRA, CCL3924NR, CCL3924NRA, CCL3930PR, CCL3930PRA, CCL3930NR, CCL3930NRA, CHL3924NR, AND CHL3924PR

Page 31 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — PARTS AVAILABLE — NOT SHOWN
Page 31 · click to enlarge
Page 31

PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual.

PART NUMBER CHL3924PR CHL3924NR KEY CCL3924PR CCL3924PRA CCL3930PR CCL3930PRA NO. CCL3924NR CCL3924NRA CCL3930NR CCL3930NRA DESCRIPTION QTY 1 105958-03 111340-02 105958-02 111340-01 Front Log 1 2 105959-03 111341-02 105959-02 111341-01 Middle Log 1 3 105960-03 111342-02 105960-02 111342-01 Back Log 1 4 105961-03 111343-02 105961-02 111343-01 Left Back Crossover Log 1 5 105962-03 111344-01 105962-03 111344-01 Left Top Crossover Log 1 6 105963-04 111345-02 105963-02 111345-01 Right Btm Crossover Log 1 7 — — 105929-02 111346-01 Right Top Crossover Log 1

PART NUMBER CHL3924PR CHL3924NR KEY CCL3924PR CCL3924NR CCL3930PR CCL3930NR NO. CCL3924PRA CCL3924NRA CCL3930PRA CCL3930NRA DESCRIPTION QTY. 8 103778-01 103778-01 103778-01 ODS Pilot Assembly LP 1 103779-01 103779-01 ODS Pilot Assembly NG 1 9 098249-01 ODS Nut 2 10 098264-02 Male Connector 1 11 111124-01 Burner Retainer Spring 1 12 099056-17 099056-16 099056-17 099056-16 Burner Orifice Injector 1 13 103284-02 Wiring Harness 1 14 102772-01 Burner 1 15 099387-09 099387-12 099387-09 099387-12 Pilot Tube 1 16 103781-02 103781-02 103781-02 Gas Control Valve LP 1 103781-01 103781-01 Gas Control Valve NG 1 17 103345-01 Lower Bracket 1 18 M11084-38 Screw, #8 x .38 7 19 ** Painted Base Assembly 1 20 098271-10 Ignitor Cable 1 21 102445-01 Piezo Ignitor 1 22 103587-02 Plate, Switch 1 23 104099-01 Heat Shield 1 24 098304-01 Screw 2 25 103784-02 Flame Adjustment Knob 1 26 103784-01 Off-Pilot-On Knob 1 27 M12461-26 Screw, Hex Slt Wsr 10-32 x .38 4 28 100609-01 100609-01 Pilot Tube (Regulator to Pilot) 1 29 099918-02 099918-02 Pilot Regulator 1 30 103342-02 103342-01 103342-02 103342-01 Burner Outlet Tube Kit LP 1 111331-03 Burner Outlet Tube Kit NG 1 31 099998-01 Switch 1

PARTS AVAILABLE — NOT SHOWN

100563-01 Warning Plate 1 103877-01 Lighting Instructions Plate 1 100565-01 Warning Plate Fastener 1 100639-01 Caution Decal 1 101137-02 Hardware Kit 1 GA6060 Lava Rock 1 111910-01 Remote Receiver (CHL Only) 1

** Not a field replaceable part.

Page 32 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — TPTH TP
Page 32 · click to enlarge
Page 32

SPECIFICATIONS

CCL3924PR CCL3018PR CCL3924PRA CCL3930PR CCL3018PRA CHL3924PR CCL3930PRA Btu (Variable) 16,000/30,000 20,000/39,000 20,000/39,000 Type Gas Propane/LP Propane/LP Propane/LP Ignition Piezo Piezo Piezo Manifold Pressure 8.0" W.C. 8.0" W.C. 8.0" W.C. Inlet Gas Pressure (in. of water)

Maximum 14" 14" 14" Minimum* 11" 11" 11" Shipping Weight 28 lbs. 66 lbs. 70 lbs. * For the purpose of input adjustment CCL3924NR CCL3018NR CCL3924NRA CCL3930NR CCL3018NRA CHL3924NR CCL3930NRA Btu (Variable) 16,000/30,000 20,000/39,000 20,000/39,000 Type Gas Natural Gas Natural Gas Natural Gas Ignition Piezo Piezo Piezo Manifold Pressure 3.5" W.C. 3.5" W.C. 3.5" W.C. Inlet Gas Pressure (in. of water)

Maximum 10.5" 10.5" 10.5" Minimum* 5" 5" 5" Shipping Weight 28 lbs. 66 lbs. 70 lbs. * For the purpose of input adjustment

WIRING DIAGRAM

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready. You can also visit DESA Heating Products’ tech- nical service web site at www.desatech.com.

Black On Off Remote

Gas Control TPTH TH

TPTH TP

SERVICE HINTS

  • When Gas Pressure Is Too Low
  • pilot will not stay lit
  • burners will have delayed ignition
  • heater will not produce specified heat
  • propane/LP gas supply may be low You may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.
Show 4 more labels / short text on this page
Receiver · Red · Red · White Thermopile
Page 33 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — PARTS CENTRAL
Page 33 · click to enlarge
Page 33

REPLACEMENT PARTS

FBD 1349 Adams Street Bowling Green, KY 42103-3414 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com

  • PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling DESA Heating Products, have ready
  • your name
  • your address
  • model and serial numbers of your heater
  • how heater was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date Usually, we will ask you to return the part to the factory.

Master Parts Dist. 1251 Mound Ave NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com

Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com

East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep

  • PARTS NOT UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central (below) or call DESA Heating Products at 1-866-672-6040 for referral information. When calling DESA Heating Products, have ready
  • model number of your heater
  • the replacement part number

Laportes Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 843-332-0191 Parts Department

PARTS CENTRAL

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com

These Parts Centrals are privately owned busi- nesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.

Tool & Equipment Co. 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department

Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-888-619-7060 sales@portableheaterparts.com techservice@portableheaterparts.com

Page 34 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — ACCESSORIES
Page 34 · click to enlarge
Page 34

ACCESSORIES

Purchase these fireplace accessories from your lo- cal dealer. If they can not supply these accessories, either contact your nearest Parts Central (page 33) or call DESA Heating Products’ Sales Department at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.

RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - CGHRCTB SERIES For all models. Allows the gas log heater to be op- erated in a manually or thermostatically-controlled mode. You can turn the gas log heater on and off without ever leaving the comfort of your easy chair. Included with CHL3924NR/PR models.

EQUIPMENT SHUTOFF VALVE GA5010 For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.

RECEIVER AND HAND-HELD REMOTE CONTROL KIT - CGHRCB SERIES For all models. Allows the gas log heater to be turned on and off by using a hand-held remote control.

FIREPLACE HOOD Black - GA6050 Brass - GA6052 Antique Brass - GA6053 For all models. Helps deflect heat away from man- tel or wall above fireplace.

CLEANING KIT - CCK (Not Shown) For all models. Your vent-free gas appliance re- quires regular cleaning and maintenance to pre- vent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.

LAVA ROCK - GA6060 (Not Shown) For all models. Order when additional rock is desired (1.8 lb. bag).

DAMPER CLAMP - GA6080 (Not Shown) For all models. Permanently opens chimney flue damper for vented operation. Can be used only with non-thermostat accessories.

INFORMATION VIDEO - 108917-01 For all models. A care and maintenance video is available by calling 1-866-672-6040. You may also email your request to productsupport@desaint.com.

Page 35 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — NOTES
Page 35 · click to enlarge
Page 35

NOTES

Page 36 of the Desa Tech Direct Vent Fireplace (CCL3930PRA) user manual — LIMITED WARRANTY COMFORT GLOW VENT-FREE GAS LOG HEATERS
Page 36 · click to enlarge
Page 36

WARRANTY INFORMATION

KEEP THIS WARRANTY

Serial No.

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY COMFORT GLOW VENT-FREE GAS LOG HEATERS

DESA Heating Products warrants this product to be free from defects in materials and components for two (2) year from the date of first purchase, provided that the product has been properly installed, operated and main- tained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a DESA Heating Products Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this prod- uct and/or DESA Heating Products who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit. This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEAR ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING PROD- UCTS’ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUD- ING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com

111161-01 Rev. D 04/04 NOT A UPC

Model · Date Purchased · 111161 01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Desa Tech Direct Vent Fireplace (CCL3930PRA)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa Tech Direct Vent Fireplace (CCL3930PRA)

Be the first to ask — other owners or our team will answer.

Original document

Desa Tech Direct Vent Fireplace (CCL3930PRA) manual PDF

36 pages·1 MB·Electric Heater·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…