EN
Desa Tech logo
Official user manual

Desa Tech Gas Log Set (CGCFTN)

30 pages·1.8 MB·Indoor Fireplace·PDF·ENDEFRITNLJA
Desa Tech Gas Log Set (CGCFTN)
Table of Contents 80 sections For more information, visit www.desatech.com For more information, visit www.desatech.com · CGCFTP CGCFTN 14,000 to 26,000 Btu/Hr with Thermostat · — Do not store or use gasoline or other · TABLE OF CONTENTS · … ShowHide
For more information, visit www.desatech.com For more information, visit www.desatech.comp.1CGCFTP CGCFTN 14,000 to 26,000 Btu/Hr with Thermostatp.1— Do not store or use gasoline or otherp.1TABLE OF CONTENTSp.2SAFETY INFORMATION ............................................................ 2p.2TROUBLESHOOTING .............................................................. 20p.2LOCAL CODES........................................................................... 3p.2SPECIFICATIONS .................................................................... 23p.2PRODUCT IDENTIFICATION ..................................................... 3p.2REPLACEMENT PARTS .......................................................... 23p.2PRODUCT FEATURES .............................................................. 4p.2SERVICE HINTS....................................................................... 23p.2TECHNICAL SERVICE ............................................................. 23p.2ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 24p.2AIR FOR COMBUSTION AND VENTILATION ........................... 5p.2PARTS CENTRALS .................................................................. 26p.2INSTALLATION ........................................................................... 7p.2OWNER’S REGISTRATION FORM .......................................... 27p.2OPERATING FIREPLACE ........................................................ 17p.2ACCESSORIES ........................................................................ 29p.2INSPECTING BURNER ............................................................ 18p.2CLEANING AND MAINTENANCE ............................................ 19p.2SAFETY INFORMATIONp.2WARNING ICON G 001 WARNINGSp.2SAFETY INFORMATION Continuedp.3LOCAL CODESp.3PRODUCT IDENTIFICATIONp.3PRODUCT FEATURESp.4ASSEMBLYp.4SAFETY PILOTp.4PIEZO IGNITION SYSTEMp.4THERMOSTATIC HEAT CONTROLp.4ASSEMBLING FIREPLACEp.4UNPACKINGp.4ASSEMBLY Continuedp.5PROVIDING ADEQUATE VENTILATIONp.5Unusually Tight Constructionp.5AIR FOR COMBUSTION AND VENTILATIONp.5AIR FOR COMBUSTION AND VENTILATION Continuedp.6Confined and Unconfined Spacep.6DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONp.6Determining if You Have a Confined or Unconfined Spacep.6VENTILATION AIRp.7Ventilation Air From Inside Buildingp.7Ventilation Air From Outdoorsp.7INSTALLATIONp.7CHECK GAS TYPEp.7INSTALLATION ITEMSp.8CEILINGp.8LOCATING FIREPLACEp.8FLOORp.8BUILT-IN FIREPLACE INSTALLATIONp.9MANTEL CLEARANCES FOR BUILT-IN INSTALLATIONp.10INSTALLING BLOWER ACCESSORY GA3450Tp.11Removing Upper Louver Assemblyp.11Installing Blower Assemblyp.12For Built-In Installationp.13Extension Cordp.14ATTACHING WOOD BASE TO SOLID FLOORp.14CONNECTING TO GAS SUPPLYp.14CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROLp.15CHECKING GAS CONNECTIONSp.16ON POSITIONp.16Pressure Testing Gas Supply Piping Systemp.16OFF POSITIONp.16OPERATING FIREPLACEp.17OPERATING FIREPLACE Continuedp.18INSPECTING BURNERp.18TO TURN OFF GASp.18PILOT FLAME PATTERNp.18TO APPLIANCEp.18Shutting Off Burner Only (pilot stays lit)p.18THERMOSTAT CONTROL OPERATIONp.18BURNER FLAME PATTERNp.18MANUAL LIGHTINGp.18PROCEDUREp.18CLEANING AND MAINTENANCEp.19CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLEp.19CABINETp.19TROUBLESHOOTINGp.20
Page 1 of the Desa Tech Gas Log Set (CGCFTN) user manual — — Do not store or use gasoline or other
Page 1 · click to enlarge
Page 1
Desa Tech Gas Log Set (CGCFTN) — For more information, visit www.desatech.com For more information, visit www.desatech.com diagram (page 1)
Fig. 1 · For more information, visit www.desatech.com For mor…

For more information, visit www.desatech.com For more information, visit www.desatech.com

Desa Tech Gas Log Set (CGCFTN) — For more information, visit www.desatech.com For more information, visit www.desatech.com diagram (page 1)
Fig. 2 · For more information, visit www.desatech.com For mor…

CGCFTP CGCFTN 14,000 to 26,000 Btu/Hr with Thermostat

Shown with Optional Cabinet Mantel/Hearth

— Do not store or use gasoline or other

flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed

by a qualified installer, service agency, or the gas supplier.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* AftermarketCompletion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference. Save this manual for future reference.

Base Accessory

Page 2 of the Desa Tech Gas Log Set (CGCFTN) user manual — Table of Contents
Page 2 · Contents
Contents

Contents

For more information, visit www.desatech.com For more information, visit www.desatech.comp.1CGCFTP CGCFTN 14,000 to 26,000 Btu/Hr with Thermostatp.1— Do not store or use gasoline or otherp.1TABLE OF CONTENTSp.2SAFETY INFORMATION ............................................................ 2p.2TROUBLESHOOTING .............................................................. 20p.2LOCAL CODES........................................................................... 3p.2SPECIFICATIONS .................................................................... 23p.2PRODUCT IDENTIFICATION ..................................................... 3p.2REPLACEMENT PARTS .......................................................... 23p.2PRODUCT FEATURES .............................................................. 4p.2SERVICE HINTS....................................................................... 23p.2TECHNICAL SERVICE ............................................................. 23p.2ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 24p.2AIR FOR COMBUSTION AND VENTILATION ........................... 5p.2PARTS CENTRALS .................................................................. 26p.2INSTALLATION ........................................................................... 7p.2OWNER’S REGISTRATION FORM .......................................... 27p.2OPERATING FIREPLACE ........................................................ 17p.2ACCESSORIES ........................................................................ 29p.2INSPECTING BURNER ............................................................ 18p.2CLEANING AND MAINTENANCE ............................................ 19p.2SAFETY INFORMATIONp.2WARNING ICON G 001 WARNINGSp.2SAFETY INFORMATION Continuedp.3LOCAL CODESp.3PRODUCT IDENTIFICATIONp.3PRODUCT FEATURESp.4ASSEMBLYp.4SAFETY PILOTp.4PIEZO IGNITION SYSTEMp.4THERMOSTATIC HEAT CONTROLp.4ASSEMBLING FIREPLACEp.4UNPACKINGp.4ASSEMBLY Continuedp.5PROVIDING ADEQUATE VENTILATIONp.5Unusually Tight Constructionp.5AIR FOR COMBUSTION AND VENTILATIONp.5AIR FOR COMBUSTION AND VENTILATION Continuedp.6Confined and Unconfined Spacep.6DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONp.6Determining if You Have a Confined or Unconfined Spacep.6VENTILATION AIRp.7Ventilation Air From Inside Buildingp.7Ventilation Air From Outdoorsp.7INSTALLATIONp.7CHECK GAS TYPEp.7INSTALLATION ITEMSp.8CEILINGp.8LOCATING FIREPLACEp.8FLOORp.8BUILT-IN FIREPLACE INSTALLATIONp.9MANTEL CLEARANCES FOR BUILT-IN INSTALLATIONp.10INSTALLING BLOWER ACCESSORY GA3450Tp.11Removing Upper Louver Assemblyp.11Installing Blower Assemblyp.12For Built-In Installationp.13Extension Cordp.14ATTACHING WOOD BASE TO SOLID FLOORp.14CONNECTING TO GAS SUPPLYp.14CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROLp.15CHECKING GAS CONNECTIONSp.16ON POSITIONp.16Pressure Testing Gas Supply Piping Systemp.16OFF POSITIONp.16OPERATING FIREPLACEp.17OPERATING FIREPLACE Continuedp.18INSPECTING BURNERp.18TO TURN OFF GASp.18PILOT FLAME PATTERNp.18TO APPLIANCEp.18Shutting Off Burner Only (pilot stays lit)p.18THERMOSTAT CONTROL OPERATIONp.18BURNER FLAME PATTERNp.18MANUAL LIGHTINGp.18PROCEDUREp.18CLEANING AND MAINTENANCEp.19CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLEp.19CABINETp.19TROUBLESHOOTINGp.20
Page 3 of the Desa Tech Gas Log Set (CGCFTN) user manual — PRODUCT IDENTIFICATION
Page 3 · click to enlarge
Page 3
Desa Tech Gas Log Set (CGCFTN) — SAFETY INFORMATION Continued diagram (page 3)
Fig. 3 · SAFETY INFORMATION Continued

SAFETY INFORMATION Continued

  • 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only). 3. If you smell gas
  • shut off gas supply
  • do not try to light any appliance
  • do not touch any electrical switch; do not use any phone in your building
  • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
  • if you cannot reach your gas supplier, call the fire department 4. This fireplace shall not be installed in a bedroom or bathroom. 5. Do not use this fireplace as a wood-burning fireplace. Use only the logs provided with the fireplace. 6. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace. 7. This fireplace is designed to be smokeless. If logs ever appear to smoke, turn off fireplace and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and fireplace burning manufacturing residues. 8. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance , page 19. 9. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture. 10. This fireplace needs fresh air ventilation to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 7. If fireplace keeps shutting off, see Troubleshooting, pages 20 through 22. 11. Do not run fireplace
  • where flammable liquids or vapors are used or stored.
  • under dusty conditions. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Never place any objects in the fireplace or on logs. 14. Do not use fireplace if any part has been under water. Immediately call a qualified service technician to inspect the room fireplace and to replace any part of the control system and any gas control which has been under water. 15. Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.
16. Operating fireplace above elevations of 4,500 feet could cause pilot outage. 17. Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger). 18. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity (propane/LP units only). 19. Provide adequate clearances around air openings.

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park Quincy, MA 02269

PRODUCT IDENTIFICATION

Desa Tech Gas Log Set (CGCFTN) — PRODUCT IDENTIFICATION diagram (page 3)
Fig. 4

Figure 1 - Vent-Free Gas Compact Fireplace

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 4 more labels / short text on this page
Fireplace Cabinet · Screen · Log Set · Ignitor Button
Page 4 of the Desa Tech Gas Log Set (CGCFTN) user manual — UNPACKING
Page 4 · click to enlarge
Page 4
Desa Tech Gas Log Set (CGCFTN) — PRODUCT FEATURES diagram (page 4)
Fig. 5

PRODUCT FEATURES

ASSEMBLY

SAFETY PILOT

Desa Tech Gas Log Set (CGCFTN) — SAFETY PILOT diagram (page 4)
Fig. 6

This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This system requires no matches, batteries, or other sources to light fireplace.

THERMOSTATIC HEAT CONTROL

ASSEMBLING FIREPLACE

This fireplace has a thermostat sensing bulb and a control valve. The thermostat will automatically modulate the heat output to maintain a consistent room temperature. This results in greater fireplace comfort. This can also result in lower gas bills.

  • Tools Required:
  • Phillips screwdriver
  • 5/16" hex wrench
  • slotted screwdriver
  • scissors

UNPACKING

Installing Log 1. Lift screen up and pull out to remove. 2. Cut two plastic straps to remove the log from the firebox cavity. 3. An optional blower is available. See Accessories, page 29. In- stall optional blower now. Follow installation instructions pro- vided with blower. 4. Remove log packaging material and discard packaging. Gently place log set on burner support (see Figure 3). The log should fit flat against top of burner support and log locator tabs fit into the slots under the log. Do not allow log to contact flame. If flame contacts log, soot will be created. 5. Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down.

1. Remove log box and fireplace from carton. IMPORTANT: The fireplace hood is inside the cardboard protective end wrap on the left side of fireplace (as viewed from front). A decal is on the outside of the cardboard end wrap stating hood is enclosed (see Figure 2). 2. Remove hood from cardboard protective end wrap as shown in Figure 2. 3. Remove all protective packaging applied to fireplace for shipment. 4. Make sure your fireplace includes one hardware packet. 5. Check fireplace for any shipping damage. If fireplace is dam- aged, promptly inform dealer where you bought fireplace.

Desa Tech Gas Log Set (CGCFTN) — UNPACKING diagram (page 4)
Fig. 7
Desa Tech Gas Log Set (CGCFTN) — UNPACKING diagram (page 4)
Fig. 8

Burner Support with Log Locator Tabs

Cardboard Protective Fireplace End Wrap

Figure 2 - Removing Fireplace Hood

Figure 3 - Assembling Fireplace

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Log

Page 5 of the Desa Tech Gas Log Set (CGCFTN) user manual — AIR FOR COMBUSTION AND VENTILATION
Page 5 · click to enlarge
Page 5
Desa Tech Gas Log Set (CGCFTN) — ASSEMBLY Continued diagram (page 5)
Fig. 9 · ASSEMBLY Continued

ASSEMBLY Assembling Fireplace (Cont.) AIR FOR COMBUSTION AND VENTILATION

ASSEMBLY Continued

Assembling Hood 1. Locate four black phillips sheet metal screws from the hard- ware packet. 2. Rotate hood as shown in Figure 4. Make sure hood tabs point toward fireplace. 3. Insert hood tabs between baffle and louvers (see Figure 4). 4. Gently rotate hood to upright position. Make sure hood tabs are behind louvers and hood is resting on firebox top (see Figure 4). 5. Align screw holes on hood with screw holes on firebox top. 6. Insert screws as shown in Figure 4. Tighten screws firmly.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space

Desa Tech Gas Log Set (CGCFTN) — PROVIDING ADEQUATE VENTILATION diagram (page 5)
Fig. 10

The information on pages 5 through 7 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable win- dows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

Figure 4 - Assembling Hood

AIR FOR COMBUSTION AND VENTILATION

Desa Tech Gas Log Set (CGCFTN) — AIR FOR COMBUSTION AND VENTILATION diagram (page 5)
Fig. 11

If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 7.

If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Fireplace Location, page 6.

Today’s homes are built more energy efficient than ever. New materi- als, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Firebox Top

Page 6 of the Desa Tech Gas Log Set (CGCFTN) user manual — Determining if You Have a Confined or Unconfined Space
Page 6 · click to enlarge
Page 6
Desa Tech Gas Log Set (CGCFTN) — AIR FOR COMBUSTION AND VENTILATION Continued diagram (page 6)
Fig. 12 · AIR FOR COMBUSTION AND VENTILATION Continued

Providing Adequate Ventilation (Cont.) Determining Fresh-Air Flow for Heater Location

AIR FOR COMBUSTION AND VENTILATION Continued

Confined and Unconfined Space

3. Add the Btu/Hr of all fuel burning appliances in the space.

The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

Vent-free heater Btu/Hr Gas water heater* Btu/Hr Gas furnace Btu/Hr Vented gas heater Btu/Hr Gas fireplace logs Btu/Hr Other gas appliances* + Btu/Hr Total = Btu/Hr

* Do not include direct-vent gas appliances. Direct-vent draws com- bustion air from the outdoors and vents to the outdoors.

* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.

ExampleGas water heater _____________ Btu/Hr Vent-free heater + _____________ Btu/Hr Total = _____________ Btu/Hr

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

Determining if You Have a Confined or Unconfined Space

Btu/Hr (maximum the space can support)

Btu/Hr (actual amount of Btu/Hr used)

Use this work sheet to determine if you have a confined or unconfined space.

Example51,200 Btu/Hr (maximum the space can support)

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

56,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/ Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

1. Determine the volume of the space (length x width x height).

Length x Width x Height = cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 7.

If additional ventilation to adjoining room is supplied with grills or open- ings, add the volume of these rooms to the total volume of the space.

2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.

B. Vent room directly to the outdoors. See Ventilation Air From Out- doors, page 7.

(volume of space) x 20 = (Maximum Btu/Hr the space

C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

Example: 2560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

Desa Tech Gas Log Set (CGCFTN) — Determining if You Have a Confined or Unconfined Space diagram (page 6)
Fig. 13 · Determining if You Have a Confined or Unconfined Spa…

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

30,000 26,000 56,000 · can support)

Page 7 of the Desa Tech Gas Log Set (CGCFTN) user manual — CHECK GAS TYPE
Page 7 · click to enlarge
Page 7
Desa Tech Gas Log Set (CGCFTN) — VENTILATION AIR diagram (page 7)
Fig. 14

AIR FOR COMBUSTION AND VENTILATION Continued

VENTILATION AIR

Desa Tech Gas Log Set (CGCFTN) — VENTILATION AIR diagram (page 7)
Fig. 15

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 5). You can also remove door into adjoining room (see option 3, Figure 5). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Figure 6 - Ventilation Air from Outdoors Shown with Optional Mantel

INSTALLATION

Desa Tech Gas Log Set (CGCFTN) — INSTALLATION diagram (page 7)
Fig. 16

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

Desa Tech Gas Log Set (CGCFTN) — INSTALLATION diagram (page 7)
Fig. 17

Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fireplace Installation, page 9)

CHECK GAS TYPE

Figure 5 - Ventilation Air from Inside Building Shown with Optional Mantel

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Outlet Air

Page 8 of the Desa Tech Gas Log Set (CGCFTN) user manual — CEILING
Page 8 · click to enlarge
Page 8
Desa Tech Gas Log Set (CGCFTN) — INSTALLATION ITEMS diagram (page 8)
Fig. 18

INSTALLATION ITEMS

IMPORTANT: Vent-free fireplaces add moisture to the air. Although this is beneficial, installing fireplace in rooms without enough venti- lation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, pages 5 through 7.

  • Before installing fireplace, make sure you have the items listed below.
  • external regulator - propane/LP only (supplied by installer)
  • piping (check local codes)
  • sealant (resistant to propane/LP gas)
  • equipment shutoff valve *
  • test gauge connection *
  • ground joint union
  • sediment trap
  • tee joint
  • pipe wrench
Desa Tech Gas Log Set (CGCFTN) — INSTALLATION ITEMS diagram (page 8)
Fig. 19
  • CAUTION: If you install the fireplace in a home garage
  • fireplace pilot and burner must be at least 18 inches above floor.
  • locate fireplace where moving vehicle will not hit it.

* A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 29.

CEILING

Desa Tech Gas Log Set (CGCFTN) — CEILING diagram (page 8)
Fig. 20

LOCATING FIREPLACE

0" Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material

You can recess firebox into the wall. You can also position fireplace in the optional cabinet or corner mantels. IMPORTANT: Only use optional cabinet or corner mantels specified in this manual. Purchase the optional mantel from your dealer (see Accessories, page 29).

FLOOR

Figure 7 - Mounting Clearances As Viewed From Front of Fireplace Shown Built In The Wall

  • WARNING: Never install the fireplace
  • in a bedroom or a bathroom
  • in a recreational vehicle
  • where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the fireplace
  • as a fireplace insert
  • in high traffic areas
  • in windy or drafty areas

CEILING

Desa Tech Gas Log Set (CGCFTN) — CEILING diagram (page 8)
Fig. 21

0" Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material

Figure 8 - Mounting Clearances As Viewed From Front of Fireplace Shown with Optional Mantel

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 9 of the Desa Tech Gas Log Set (CGCFTN) user manual — BUILT-IN FIREPLACE INSTALLATION
Page 9 · click to enlarge
Page 9
Desa Tech Gas Log Set (CGCFTN) — BUILT-IN FIREPLACE INSTALLATION diagram (page 9)
Fig. 22
  • For convenience and efficiency, install fireplace
  • where there is easy access for operation, inspection, and service.
  • in coldest part of room An optional blower kit is available from your dealer. See Accessories , page 29. If planning to use blower, locate fireplace near an electrical outlet.

3. Install gas piping to fireplace location. This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping. 4. If you have not assembled firebox, follow instructions on page 4. 5. Carefully set fireplace in front of rough opening with back of fireplace inside wall opening. 6. Attach flexible gas line to fireplace gas regulator. See Con- necting to Gas Supply, page 14. 7. Bend four nailing flanges on outer casing with pliers (see Figure 11). 8. Attach fireplace to wall studs using nails or wood screws through holes in nailing flange. 9. Check all gas connections for leaks. See Checking Gas Con- nections, page 16. 10. If using optional brass trim kit, install the trim after final fin- ishing and/or painting of wall. See instructions included with brass trim accessory for attaching brass trim.

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. An optional brass trim kit accessory is available (see Accesso- ries, page 29). Brass trim will extend past sides of fireplace approxi- mately 1/2 inch. This will cover the rough edges of the wall opening. If installing a built-in mantel above the fireplace, you must follow the clearances shown in Figure 12, page 10. Follow the instructions below to install the fireplace in this manner. Note: Your Comfort Glow fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace.

Height 26" 26 7/8"

Front Width 26 3/4" 26 7/8"

Depth 9 1/2" 10 1/2"

Bottom 3/4" 3/4"

10 1/2"

365/8" 257/8"

513/4" 267/8" 1. Frame in rough opening. Use dimensions shown in Figure 9 for the rough opening. If installing in a corner, use dimensions shown in Figure 10 for the rough opening. The height is 26 7/8" which is the same as the wall opening above. 2. If installing GA3450T blower accessory, do so at this time. Fol- low instructions included with blower accessory. Note: If not installing blower accessory, you may wish to run electrical wir- ing to your fireplace for future blower installation (see Accesso- ries, page 29). Use only approved three-wire electrical wiring. Note: A qualified installer should make all electrical connections.

267/8"

3/4" Off The Floor Minimum

Figure 10 - Rough Opening for Installing in Corner

267/8"

Figure 9 - Rough Opening for Installing in Wall

Desa Tech Gas Log Set (CGCFTN) — BUILT-IN FIREPLACE INSTALLATION diagram (page 9)
Fig. 23
Desa Tech Gas Log Set (CGCFTN) — BUILT-IN FIREPLACE INSTALLATION diagram (page 9)
Fig. 24

Nails or Wood Screws

Figure 11 - Attaching Fireplace to Wall Studs

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Actual Framing

Page 10 of the Desa Tech Gas Log Set (CGCFTN) user manual — MANTEL CLEARANCES FOR BUILT-IN INSTALLATION
Page 10 · click to enlarge
Page 10
Desa Tech Gas Log Set (CGCFTN) — MANTEL CLEARANCES FOR BUILT-IN INSTALLATION diagram (page 10)
Fig. 25

Built-In Fireplace Installation (Cont.) Mantel Clearances for Built-In Installation Optional Mantel Installation

Desa Tech Gas Log Set (CGCFTN) — MANTEL CLEARANCES FOR BUILT-IN INSTALLATION diagram (page 10)
Fig. 26

10" Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches.

Desa Tech Gas Log Set (CGCFTN) — MANTEL CLEARANCES FOR BUILT-IN INSTALLATION diagram (page 10)
Fig. 27

MANTEL CLEARANCES FOR BUILT-IN INSTALLATION

Figure 12 - Minimum Mantel Clearances for Built-In Installation

OPTIONAL MANTEL INSTALLATION Note: Refer to instructions provided with the mantel for assembly instructions. Refer to instructions below for system installation. Refer to instructions on page 4 for firebox assembly. Blower accessory should be installed if it is being used (see Installing Blower Accessory GA3450T, pages 11 through 13). 1. Unscrew four brass screws that attach top louver to fireplace. Remove louver from fireplace and set aside. 2. Place fireplace on wood base. 3. Place mantel around fireplace/base assembly. 4. Assemble brass trim kit. See Assembling Brass Trim, page 11. 5. Firmly snap brass trim kit on shoulder screws. Shoulder screws are located on fireplace cabinet (see Figure 13).

If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

Desa Tech Gas Log Set (CGCFTN) — MANTEL CLEARANCES FOR BUILT-IN INSTALLATION diagram (page 10)
Fig. 28
  • NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following:
  • raise the mantel to an acceptable height
  • remove the mantel
Desa Tech Gas Log Set (CGCFTN) — MANTEL CLEARANCES FOR BUILT-IN INSTALLATION diagram (page 10)
Fig. 29

Hole for 3" Wood Screw for Attaching Fireplace to Mantel

Hole for 3" Wood Screw for Attaching Fireplace to Wooden Base

Figure 13 - Attaching Brass Trim to Fireplace

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Mantel Shelf · Side of Firebox · Shoulder Screws

Page 11 of the Desa Tech Gas Log Set (CGCFTN) user manual — INSTALLING BLOWER ACCESSORY GA3450T
Page 11 · click to enlarge
Page 11
Desa Tech Gas Log Set (CGCFTN) — INSTALLING BLOWER ACCESSORY GA3450T diagram (page 11)
Fig. 30

6. Align brass trim kit for flush fit around opening. 7. Use two 3" wood screws provided and attach fireplace base to wooden base (see Figure 13, page 10). 8. Remove brass trim kit and mantel. Be careful not to damage wall or mantel. 9. Place wood base next to wall at installation location. 10. Attach wood base to floor with two 1 3/4" black screws provided (see Figure 14). If the floor is concrete use anchor method (see Attaching Wood Base to Solid Floor, page 14). 11. Install gas line. See Connecting To Gas Supply, page 14. 12. Check for leaks. See Checking Gas Connections, page 16. 13. Place mantel around fireplace. Be careful not to damage wall or mantel. 14. Place brass trim kit on the shoulder screws located on the side and top of the fireplace. Firmly snap the brass trim over the shoulder screws on fireplace (see Figure 13). 15. Adjust assembly to remove any gaps. Attach remaining two 3" wood screws from hardware pack through openings inside of fireplace sides into the mantel. The openings are located at top behind the area for the louvers (see Figure 13, page 10). 16. Reinstall top louvers.

Desa Tech Gas Log Set (CGCFTN) — INSTALLING BLOWER ACCESSORY GA3450T diagram (page 11)
Fig. 31

INSTALLING BLOWER ACCESSORY GA3450T

Removing Upper Louver Assembly

To install the blower accessory, you must first remove the upper louver assembly. 1. Lift screen off heater. 2. Remove 4 screws from louver assembly (see Figure 16). Save these screws. 3. Pull louver assembly straight out from the cabinet. Be careful not to scratch the paint. Set louver assembly and screws aside.

1 3/4" Screw

Blower Bracket Mounting Holes

Desa Tech Gas Log Set (CGCFTN) — INSTALLING BLOWER ACCESSORY GA3450T diagram (page 11)
Fig. 32

Figure 14 - Attaching Wood Base to Floor

ASSEMBLING BRASS TRIM (Brass trim shipped with mantel) 1. Remove packaging from three remaining pieces of brass trim. 2. Locate two adjusting plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 15. 4. Slide one end of adjusting plate/shim in slot on mitered edge of top brass trim (see Figure 15). 5. Slide other end of adjusting plate/shim in slot on mitered edge of side brass trim (see Figure 15). 6. While firmly holding edges of brass trim together, tighten both set screws on the adjusting plate with slotted screwdriver. 7. Repeat steps 1 through 6 for other corner. 8. Set brass assembly aside for later installation.

Figure 16 - Removing Upper Louver Assembly

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 5 more labels / short text on this page
Set Screws · Top Brass Trim · Side Brass Trim · Adjusting Plate · Wood Base
Page 12 of the Desa Tech Gas Log Set (CGCFTN) user manual — Installing Blower Assembly
Page 12 · click to enlarge
Page 12
Desa Tech Gas Log Set (CGCFTN) — Installing Blower Assembly diagram (page 12)
Fig. 33 · Installing Blower Assembly

Removing Valve Cover Shield 1. Open bottom louver assembly by swinging the assembly down (see Figure 17). 2. Using short Phillips screwdriver, remove the screw under the center of the branch support. Rotate valve cover shield clock- wise and slide out. IMPORTANT: Do not remove shoulder screw on the left side of valve cover shield. Slide the valve cover shield off of the shoulder screw (see Figure 17). Note: If you do not have a short Phillips screwdriver, the screen, log set, and branch support must be removed so a longer screw- driver may be used. See Connecting Equipment Shutoff Valve to Heater Control, page 15, steps 1 and 2.

3. Note the wire locations on back of AUTO/OFF/ON switch. The terminals on back of switch are numbered 1, 2, and 3. Carefully remove red wire from terminal 1 and blue wire from terminal 3. Black wire can remain on middle terminal 2 (see Figure 18). 4. Carefully disconnect green and white wires at their insulated connectors. 5. In top of the heater cabinet, locate the four mounting holes on the outer casing. Align these four holes with those on the blower bracket assembly. Attach blower bracket assembly to the outer casing with 4 #10 screws provided (see Figure 18). 6. Route the wire harness through the hole in left side of baffle. Pull wire harness through lower opening above where the valve shield was removed. (see Figure 18). 7. Insert the 4 wire harness into one of the round holes in the rear of the valve cover shield and through the rectangular hole in the front of shield (see Figure 18). 8. Reconnect red wire to switch position 3. Reconnect blue wire to switch position 1. Reconnect green and white wires.

Wiring Routing Hole in Baffle

Figure 17 - Removing Valve Cover Shield

Installing Blower Assembly

Figure 18 - Installing Blower Bracket Assembly

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 18 more labels / short text on this page
Branch Support · Shoulder Screw · Remove Screw · Valve Cover Shield · Blower Bracket Assembly · Wire Harness · Screw · Baffle · Bottom Louver Assembly · Snap Bushings · Switch · Power Cord · Red · Switch Plate · Blue · Valve Cover Shield · Wire Harness · Box Cover
Page 13 of the Desa Tech Gas Log Set (CGCFTN) user manual — For Built-In Installation
Page 13 · click to enlarge
Page 13
Desa Tech Gas Log Set (CGCFTN) — For Built-In Installation diagram (page 13)
Fig. 34 · For Built-In Installation

9. Install the switch plate on the valve cover shield with 2 #10 screws provided (see Figure 19). Reinstall the valve cover shield. Route power cord out of the cabinet by inserting it through the bushing on the outer casing (see Figure 18, page 12). Plug fan kit into 120-Volt grounded power supply and test operation. Note: When switch is in the AUTO position, the fan will start after the heater has run for a few moments. The fan will continue to run for several moments after the heater has been turned off. When switch is in the ON position, the fan will run until turned to OFF. Reinstall upper louver assem- bly and hood if previously removed, (see Figure 16, page 11). Close lower louver door.

5. Plug power cord to the outlet receptacle (not provided) as shown in Figure 21. Wind the extra cable in power cord and and tie it up with the plastic wire strap (see Figure 21). Set the cable bundle between the burner bracket and outer casing, away from the burner. 6. Reinstall valve cover shield. 7. Test to make sure the blower is working properly. 8. Reinstall upper louver assembly and hood if previously removed, (see Figure 16, page 11). Close lower louver door.

Desa Tech Gas Log Set (CGCFTN) — For Built-In Installation diagram (page 13)
Fig. 35 · For Built-In Installation
Desa Tech Gas Log Set (CGCFTN) — For Built-In Installation diagram (page 13)
Fig. 36 · For Built-In Installation

Figure 20 - Wiring Diagram For Blower Accessory Built-In Installation

Figure 19 - Installing Switch Plate to Valve Cover Shield

For Built-In Installation

Follow instructions in Removing Valve Cover Shield, page 12, then 1. Install a snap bushing found in hardware kit into one of the holes found on rear of valve cover shield. The other hole is for a strain relief clamp (not supplied) to secure incoming electri- cal supply. 2. Follow steps 2 through 6 in Installing Blower Assembly, begin- ning on page 12. Also remove black wire from middle switch terminal 2. 3. Remove black plastic strain relief and power cord from switch plate. The power cord supplied will not be used in built-in in- stallations. Pop in the plastic snap bushing found in hardware kit into the hole left by supply cord/strain relief. 4. A licensed electrician must follow the wiring diagram to con- nect incoming electrical supply to fan kit wiring harness (see Figure 20). Figure 21 - Installing Blower Bracket Assembly

Valve Cover Shield Box Cover Wire Harness

Clamp Connector (not included)

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 12 more labels / short text on this page
Fan Switch (Auto/Off/On) · Valve Cover Shield · Switch Plate · Blower Bracket Assembly · Wire Harness · Screw · Switch · Power Cord · Outlet Receptacle · Blue Red · Switch Plate · Plastic Wire Strap
Page 14 of the Desa Tech Gas Log Set (CGCFTN) user manual — CONNECTING TO GAS SUPPLY
Page 14 · click to enlarge
Page 14
Desa Tech Gas Log Set (CGCFTN) — Extension Cord diagram (page 14)
Fig. 37 · Extension Cord

Installing Blower Accessory - GA3450T (Cont.) Attaching Wood Base to Solid Floor Connecting to Gas Supply

For propane/LP units, installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent point- ing down as shown in Figure 23. Pointing the vent down protects it from freezing rain or sleet.

Extension Cord

Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An undersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

ATTACHING WOOD BASE TO SOLID FLOOR

Desa Tech Gas Log Set (CGCFTN) — ATTACHING WOOD BASE TO SOLID FLOOR diagram (page 14)
Fig. 38

For attaching base to solid floors (concrete or masonry)

Note: Floor anchors and mounting screws are in hardware package. The hardware package is provided with fireplace. 1. Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep. 2. Fold floor anchor as shown in Figure 22. 3. Insert floor anchor (wings first) into hole. Tap anchor flush to floor. 4. Insert mounting screws through base and into floor anchors. 5. Tighten screws until base is firmly fastened to floor.

Figure 22 - Folding Anchor

CONNECTING TO GAS SUPPLY

Figure 23 - External Regulator with Vent Pointing Down

Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 24).

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Vent Pointing Down

Page 15 of the Desa Tech Gas Log Set (CGCFTN) user manual — ©
Page 15 · click to enlarge
Page 15
Desa Tech Gas Log Set (CGCFTN) — CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROL diagram (page 15)
Fig. 39

INSTALLATION Connecting to Gas Supply (Cont.) Connecting Equipment Shutoff Valve to Heater Control

We recommend that you install a sediment trap in supply line as shown in Figure 24. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and fireplace. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

4. Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line/equipment shutoff valve (see Figure 26). 5. Check all gas connections for leaks. See Checking Gas Connections, page 16. 6. Replace branch support back into fireplace. Feed flexible gas line into fireplace base area while replacing branch support. Make sure the entire flexible gas line is in fireplace base area. Reattach branch support to fireplace with screws removed in step 2.

CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap*

Desa Tech Gas Log Set (CGCFTN) — CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROL diagram (page 15)
Fig. 40

PROPANE/LP From External Regulator (11" W.C. to 14" W.C. Pressure)

Desa Tech Gas Log Set (CGCFTN) — CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROL diagram (page 15)
Fig. 41

NATURAL From Gas Meter (5" W.C. to 10.5" W.C. Pressure)

Pipe Cap Tee Nipple Joint

Figure 24 - Gas Connection

* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 29.

CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROL

  • Installation Items Needed
  • Phillips screwdriver
  • sealant (resistant to propane/LP gas, not provided) 1. Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove. 2. Remove screws that attach branch support to fireplace (see Figure 25). Carefully lift up branch support and remove from fireplace (see Figure 25). 3. Route flexible gas line, included, from fireplace control to equipment shutoff valve through side or rear access holes in outer casing.

Figure 25 - Removing Log Base Assembly From Fireplace

To Fireplace Gas Regulator Equipment Shutoff Valve Provided by Installer

©

PROPANE/LP To External Regulator

Flexible Gas Line from Fireplace Gas Regulator Provided with Fireplace

©

Desa Tech Gas Log Set (CGCFTN) — © diagram (page 15)
Fig. 42

Figure 26 - Attaching Flexible Gas Line to Equipment Shutoff Valve

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Shoulder Screw · Sediment Trap · Flexible Gas Line

Page 16 of the Desa Tech Gas Log Set (CGCFTN) user manual — OFF POSITION
Page 16 · click to enlarge
Page 16
Desa Tech Gas Log Set (CGCFTN) — CHECKING GAS CONNECTIONS diagram (page 16)
Fig. 43

CHECKING GAS CONNECTIONS

Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Figure 27). 2. Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to thermostat gas valve (see Figures 28 and 29). Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Light fireplace (see Operating Fireplace, pages 17 and 18). Check all other internal joints for leaks. 7. Turn off fireplace (see To Turn Off Gas to Appliance, page 18). 8. Replace front panel.

Desa Tech Gas Log Set (CGCFTN) — CHECKING GAS CONNECTIONS diagram (page 16)
Fig. 44

ON POSITION

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping sys- tem. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/ LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 4. Check all joints of gas supply piping system. Apply a noncor- rosive leak detection fluid to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

OFF POSITION

Figure 27 - Equipment Shutoff Valve

Desa Tech Gas Log Set (CGCFTN) — OFF POSITION diagram (page 16)
Fig. 45

Figure 28 - Checking Gas Joints Shown with Optional Mantel (Propane/LP Gas)

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 27). 2. Pressurize supply piping system by either opening propane/ LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air. 3. Check all joints from gas meter for natural or propane/LP sup- ply to equipment shutoff valve (see Figures 28 and 29). Ap- ply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak. 4. Correct all leaks at once.

Desa Tech Gas Log Set (CGCFTN) — OFF POSITION diagram (page 16)
Fig. 46

Figure 29 - Checking Gas Joints Shown with Optional Mantel (Natural Gas)

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Equipment Shutoff Valve · Open · Closed

Page 17 of the Desa Tech Gas Log Set (CGCFTN) user manual — OPERATING FIREPLACE
Page 17 · click to enlarge
Page 17
Desa Tech Gas Log Set (CGCFTN) — OPERATING FIREPLACE diagram (page 17)
Fig. 47

OPERATING FIREPLACE

5. Turn control knob counterclockwise to the PI- LOT position. Press in control knob for five (5) seconds (see Figure 30). Note: You may be running this fireplace for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system. • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. 6. With control knob pressed in, push down and release ig- nitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor but- ton until pilot lights. Note: If pilot does not stay lit, refer to Troubleshooting, pages 20 through 22. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Pro- cedure, page 18. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Note: If pilot goes out, repeat steps 3 through 7. This fire- place has a safety interlock system. Wait one (1) minute before lighting pilot again. 8. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

Desa Tech Gas Log Set (CGCFTN) — OPERATING FIREPLACE diagram (page 17)
Fig. 48
  • A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS
  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Desa Tech Gas Log Set (CGCFTN) — OPERATING FIREPLACE diagram (page 17)
Fig. 49

Figure 30 - Control Knob In The OFF Position

1. STOP! Read the safety information above. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.

Figure 31 - Pilot

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Show 4 more labels / short text on this page
Control Knob · Ignitor Button · Thermocouple Pilot Burner · Ignitor Electrode
Page 18 of the Desa Tech Gas Log Set (CGCFTN) user manual — MANUAL LIGHTING
Page 18 · click to enlarge
Page 18
Desa Tech Gas Log Set (CGCFTN) — OPERATING FIREPLACE Continued diagram (page 18)
Fig. 50 · OPERATING FIREPLACE Continued

To Turn Off Gas To Appliance Thermostat Control Operation Manual Lighting Procedure INSPECTING BURNER

OPERATING FIREPLACE Continued

INSPECTING BURNER

Check pilot flame pattern and burner flame pattern often.

TO TURN OFF GAS

PILOT FLAME PATTERN

TO APPLIANCE

Figure 32 shows a correct pilot flame pattern. Figure 33 shows an incorrect pilot flame pattern. The incorrect pilot flame is not properly heating the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.

Shutting Off Fireplace 1. Turn control knob clockwise Clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed.

  • If pilot flame pattern is incorrect, as shown in Figure 33
  • turn fireplace off (see To Turn Off Gas to Appliance )
  • see Troubleshooting , pages 20 through 22

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

THERMOSTAT CONTROL OPERATION

The thermostatic control used on this fireplace differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this fireplace senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the heater will cycle back on when room temperature drops below the set temperature.

Figure 32 - Correct Pilot Flame Pattern (Propane/LP Shown)

Figure 33 - Incorrect Pilot Flame Pattern (Propane/LP Shown)

The control knob can be set to any heat level between HI and LO.

BURNER FLAME PATTERN

Figure 34 shows a correct burner flame pattern. Figure 35 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows sporadic, irregular flame tipping. The flame should not be dark or have an orange/reddish tinge.

MANUAL LIGHTING

PROCEDURE

  • If burner flame pattern is incorrect, as shown in Figure 35
  • turn fireplace off (see To Turn Off Gas to Appliance )
  • see Troubleshooting , pages 20 through 22
1. Follow steps 1 through 5 under Lighting Instructions , page 17. 2. With control knob pressed in, strike match. Hold match to pilot until pilot lights. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instructions , page 17.

Figure 34 - Correct Burner Flame Pattern

Figure 35 - Incorrect Burner Flame Pattern

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Thermocouple Pilot Burner · Thermocouple Pilot Burner

Page 19 of the Desa Tech Gas Log Set (CGCFTN) user manual — CABINET
Page 19 · click to enlarge
Page 19
Desa Tech Gas Log Set (CGCFTN) — CLEANING AND MAINTENANCE diagram (page 19)
Fig. 51

CLEANING AND MAINTENANCE Cleaning Burner Injector Holder and Pilot Air Inlet Hole

CLEANING AND MAINTENANCE

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 37). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Desa Tech Gas Log Set (CGCFTN) — CLEANING AND MAINTENANCE diagram (page 19)
Fig. 52

Primary Air Inlet Holes

Figure 36 - Injector Holder On Outlet Burner Tube

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

Pilot Assembly Pilot Air Inlet Hole

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the direc- tions on the can. If you don't follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 36). 3. Blow air through the ports/slots and holes in the burner. 4. Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle. 5. Blow air into the primary air holes on the injector holder. 6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Figure 37 - Pilot Inlet Air Hole (Propane/LP Shown)

CABINET

Air Passageways • Use a vacuum cleaner or pressurized air to clean.

Exterior • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Injector Holder · Ports/Slots · Burner Tube

Page 20 of the Desa Tech Gas Log Set (CGCFTN) user manual — OBSERVED PROBLEM
Page 20 · click to enlarge
Page 20
Desa Tech Gas Log Set (CGCFTN) — TROUBLESHOOTING diagram (page 20)
Fig. 53

TROUBLESHOOTING

Desa Tech Gas Log Set (CGCFTN) — TROUBLESHOOTING diagram (page 20)
Fig. 54

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1. Ignitor cable pinched or wet
1. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry 2. Reconnect ignitor cable
2. Ignitor electrode not connected to ignitor cable 3. Broken ignitor cable 4. Bad piezo ignitor 5. Ignitor electrode broken 6. Ignitor electrode positioned wrong
3. Replace ignitor cable 4. Replace piezo ignitor 5. Replace pilot assembly 6. Replace pilot assembly

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1. Gas supply turned off or equipment shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed
1. Turn on gas supply or open equipment shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5. Contact local propane/LP gas company 6. Clean ODS/pilot (see Cleaning and Maintenance, page 19) or replace ODS/ pilot assembly 7. Replace gas regulator
5. Depleted gas supply (propane/LP only) 6. ODS/pilot is clogged
7. Gas regulator setting is not correct

ODS/pilot lights but flame goes out when control knob is released

1. Control knob not fully pressed in 2. Control knob not pressed in long enough
1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 30 seconds 3. Wait one minute for safety interlock system to reset. Repeat ignition operation 4. Fully open equipment shutoff valve 5. Hand tighten until snug, then tighten 1/4 turn more 6. A) Contact local propane/LP or natural gas company
3. Safety interlock system has been triggered
4. Equipment shutoff valve not fully open 5. Thermocouple connection loose at control valve 6. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/pilot 7. Thermocouple damaged 8. Control valve damaged

B) Clean ODS/pilot (see Cleaning and Maintenance, page 19) or replace ODS/ pilot assembly

7. Replace pilot assembly 8. Replace control valve

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 21 of the Desa Tech Gas Log Set (CGCFTN) user manual — OBSERVED PROBLEM
Page 21 · click to enlarge
Page 21
Desa Tech Gas Log Set (CGCFTN) — TROUBLESHOOTING diagram (page 21)
Fig. 55

TROUBLESHOOTING Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1. Burner orifice is clogged
1. Clean burner (see Cleaning and maintenance, page 19) or replace burner orifice 2. Contact local propane/LP or natural gas company
2. Inlet gas pressure is too low

Delayed ignition of burner

1. Manifold pressure is too low
1. Contact local propane/LP or natural gas company 2. Clean burner (see Cleaning and Maintenance, page 19) or replace burner orifice
2. Burner orifice is clogged

Burner backfiring during combustion

1. Burner orifice is clogged or damaged
1. Clean burner (see Cleaning and Maintenance, page 19) or replace burner orifice 2. Replace burner pressure 3. Contact local propane/LP or natural gas company 4. Replace gas regulator
2. Burner damaged 3. Low inlet gas pressure
4. Gas regulator defective

Yellow flame during burner combustion

1. Not enough air
1. Check burner for dirt and debris. If found, clean burner (see Cleaning and Maintenance, page 19) 2. Replace gas regulator
2. Gas regulator defective

Slight smoke or odor during initial operation

1. Residues from manufacturing processes
1. Problem will stop after a few hours of operation

Fireplace produces a whistling noise when burner is lit

1. Turning control knob to HI position when burner is cold 2. Air in gas line
1. Turn control knob to LO position and let warm up for a minute 2. Operate burner until air is removed from line. Have gas line checked by local propane/LP gas company 3. Observe minimum installation clearances (see Figures 7 and 8, page 8) 4. Clean burner (see Cleaning and Maintenance, page 19) or replace burner orifice
3. Air passageways on fireplace blocked
4. Dirty or partially clogged burner orifice

White powder residue forming within burner box or on adjacent walls or furniture

1. When heated, vapors from furniture polish, wax, carpet cleaners, etc. may turn into white powder residue
1. Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 22 of the Desa Tech Gas Log Set (CGCFTN) user manual — OBSERVED PROBLEM
Page 22 · click to enlarge
Page 22
Desa Tech Gas Log Set (CGCFTN) — TROUBLESHOOTING diagram (page 22)
Fig. 56

TROUBLESHOOTING Continued

Desa Tech Gas Log Set (CGCFTN) — TROUBLESHOOTING Continued diagram (page 22)
Fig. 57 · TROUBLESHOOTING Continued
  • WARNING: If you smell gas
  • Shut off gas supply.
  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces a clicking/ticking noise just after burner is lit or shut off

1. Metal expanding while heating or contracting while cooling
1. This is common with most fireplaces. If noise is excessive, contact qualified service person

Fireplace produces unwanted odors

1. Fireplace burning vapors from paint, hair spray, glues, etc. (see IMPORTANT statement above) 2. Low fuel supply 3. Gas leak. See Warning statement at top of page
1. Ventilate room. Stop using odor causing products while fireplace is running
2. Refill supply tank 3. Locate and correct all leaks (see Checking Gas Connections , page 16)

Fireplace shuts off in use (ODS operates)

1. Not enough fresh air is available 2. Low line pressure
1. Open window and/or door for ventilation 2. Contact local propane/LP or natural gas company 3. Clean ODS/pilot (see Cleaning and Maintenance, page 16)
3. ODS/pilot is partially clogged

Gas odor even when control knob is in OFF position

1. Gas leak. See Warning statement at top of page 2. Control valve defective
1. Locate and correct all leaks (see Checking Gas Connections , page 16) 2. Replace control valve

Gas odor during combustion

1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement at top of page
1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections , page 16)

Moisture/condensation noticed on windows

1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and Ventilation requirements (page 5)

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 23 of the Desa Tech Gas Log Set (CGCFTN) user manual — PARTS NOT UNDER WARRANTY
Page 23 · click to enlarge
Page 23
Desa Tech Gas Log Set (CGCFTN) — TROUBLESHOOTING diagram (page 23)
Fig. 58

SPECIFICATIONS

CGCFTP CGCFTN Btu (Variable) 14,000/26,000 14,000/26,000 Type Gas Propane/LP Only Natural Only Ignition Piezo Piezo Pressure Regulator Setting 8" W.C. 3" W.C. Inlet Gas Pressure (in. of water)*

Maximum 14" 10.5" Minimum 11" 5" Dimensions, Inches (H x W x D)

Fireplace 25 7/8 x 26 13/16 x 9 3/8 25 7/8 x 26 13/16 x 9 3/8 Carton 32 5/8 x 27 3/16 x 11 5/8 32 5/8 x 27 3/16 x 11 5/8 Weight, pounds

Fireplace 44 1/2 lbs. 44 1/2 lbs. Shipping 48 lbs. 48 lbs.

* For purposes of input adjustment

REPLACEMENT PARTS

SERVICE HINTS

  • When Gas Pressure Is Too Low
  • pilot will not stay lit
  • burner will have delayed ignition
  • fireplace will not produce specified heat
  • propane/LP gas supply may be low (propane/LP only)

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA Heating Products’ Techni- cal Service Department at 1-866-672-6040 for referral information.

You may feel your gas pressure is too low. If so, contact your local propane/LP or natural gas supplier.

  • When calling DESA Heating Products, have ready
  • your name
  • your address
  • model and serial numbers of your fireplace
  • how fireplace was malfunctioning
  • type of gas used (propane/LP or natural gas)
  • purchase date

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical service web site at www.desatech.com

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product or Parts Central (see page 26). If they can’t supply original replacement part(s) call DESA Heating Products at 1-866-672-6040 for referral information.

  • When calling DESA Heating Products, have ready:
  • model number of your fireplace
  • the replacement part number

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 24 of the Desa Tech Gas Log Set (CGCFTN) user manual — MODELS CGCFTP AND CGCFTN
Page 24 · click to enlarge
Page 24
Desa Tech Gas Log Set (CGCFTN) — TROUBLESHOOTING diagram (page 24)
Fig. 59

ILLUSTRATED PARTS BREAKDOWN

MODELS CGCFTP AND CGCFTN

Desa Tech Gas Log Set (CGCFTN) — MODELS CGCFTP AND CGCFTN diagram (page 24)
Fig. 60

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 25 of the Desa Tech Gas Log Set (CGCFTN) user manual — PARTS AVAILABLE — NOT SHOWN
Page 25 · click to enlarge
Page 25

PARTS LIST Models CGCFTP and CGCFTN

PARTS LIST

KEY PART NUMBER NO. CGCFTP CGCFTN DESCRIPTION QTY.

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual.

1 102633-02 102633-02 Outer Casing Top 1 2 102624-02 102624-02 Outer Casing 1 3 099230-02 099230-02 Shoulder Screw 14 4 098304-01 098304-01 Screw, #10 x 3/8" 16 5 109824-05 109824-05 Burner 1 6 103209-01 103209-01 Louvered Door 1 7 102635-02 102635-02 Left and Right Side Front 2 8 M11084-26 M11084-26 Hex Head Screw, #10 x 3/8" 28 9 103209-05 103209-05 Top Louver 1 10 104281-02CK 104281-02CK Firebox Hood 1 11 102638-01 102638-01 Firebox Top 1 12 104286-01 104285-01 ODS/Pilot Assembly 1 13 ** ** Firebox Wrapper 1 14 099211-01 099211-01 Control Bracket Screw 2 15 103963-01 103963-01 Inlet Tube 1 16 102834-01 102834-01 Outlet Tube 1 17 101629-02 101629-02 Bushing 1 18 098303-02 098303-02 Regulator Screw 2 19 ** ** Outer Shell Base 1 20 102649-02 102649-02 Branch Support 1 21 099415-09 099415-10 Gas Regulator 1 22 102875-01 102875-01 Regulator Bracket 1 23 101381-01 101381-01 Valve Cover and Piezo 1 24 099387-11 099387-11 Pilot Tube 1 25 098271-06 098271-06 Ignitor Cable 1 26 107186-01 107186-02 Injector 1 27 101629-01 101629-01 Bushing 1 28 098249-01 098249-01 Nut, M5 2 29 098522-26 098522-23 Gas Valve 1 30 102639-01 102639-01 Baffle 1 31 101628-01 101628-01 Flexible Connector 1 32 102869-01 102869-01 Control Bracket 1 33 102731-01 102731-01 Control Shield 1 34 103295-03CK 103295-03CK Screen Assembly 1 35 107154-01 107154-01 Log Set 1 36 104313-01 104313-01 Hinge, Right 1 37 104313-02 104313-02 Hinge, Left 1 38 M10908-2 M10908-2 Hinge Screws 4 39 103734-01 103734-01 Burner Support 2 40 097809-03 097809-03 3/8" NPT x 3/8" Flare Brass Fitting 1 41 101006-02 101006-02 Bracket, Pilot 1 42 098304-03 098304-03 Screw, #8 x 3/8" 4 43 ___ 107634-02 NG Conversion Plate 1 44 M10908-75 M10908-75 Hex wsr head tapping screw 1

PARTS AVAILABLE — NOT SHOWN

101054-01 101054-01 Lighting Instructions Plate 1 100563-01 100563-01 Warning Plate 1 103470-01 103470-01 Hardware Package 1

** Part not available for field replacement.

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 26 of the Desa Tech Gas Log Set (CGCFTN) user manual — PARTS CENTRALS
Page 26 · click to enlarge
Page 26
Desa Tech Gas Log Set (CGCFTN) — TROUBLESHOOTING diagram (page 26)
Fig. 61

PARTS CENTRALS

These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories.

Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department

FBD 1349 Adams St. Bowling Green, KY 42103-3413 270-846-1199 1-800-654-8534 Fax: 1-800-846-0090 franktalk@aol.com

East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764-1542 732-870-8809 1-800-755-8809 www.njplaza.com/ecep

Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-800-362-6951 Parts Department sales@portableheaterparts.com techservice@portableheaterparts.com

Laportes Parts & Service 2444 N. 5th Street Hartsville, SC 29550-7704 803-332-0191 Parts Department

Master Parts Distributors 1251 Mound Ave. NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com

Cans Unlimited, Inc. P.O. Box 645 Taylor, SC 29687-0013 All States 803-879-3009 1-800-845-5301 cuisales@aol.com

Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.washerparts.com

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 27 of the Desa Tech Gas Log Set (CGCFTN) user manual — OWNER'S REGISTRATION FORM
Page 27 · click to enlarge
Page 27

OWNER'S REGISTRATION FORM

In order to provide better customer service for this and future purchases, we recommend that you register your product with us. You can register online at www.desatech.com. If access to our website is not available to you, please complete this Owner’s Registration Form and mail to the address on the back of this owner’s manual. Please provide the following product information:

Brand(Comfort Glow, Vanguard, etc.)
Model(EFP33PR, VTGH33NR, etc.)

Date Purchased: Note: Keep receipt for warranty verification.

Serial Number: 7 or 9 digit number located on product or identification tag.

First NameLast Name:

Address:

CityState: Zip: Country:
Home Phone( ) -

E-Mail:

Please answer the following questions to register your product with DESA Heating Products:

1. Where will the product be used?

❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other

2. If you bought this product yourself, did you plan to purchase this type of product before going into the store? ❍ Yes ❍ No
3. Who selected the product? ❍ Male ❍ Female ❍ Both
4. What is the population of your area? ❍ Under 10,000 ❍ 10,000 to 25,000 ❍ 25,000 to 50,000 ❍ 50,000 to 100,000

❍ 100,000 to 250,000 ❍ Over 250,000

5. What is your primary source of heat? ❍ Propane (LP Gas) ❍ Fuel Oil ❍ Wood ❍ Natural Gas ❍ Electric ❍ Other
6. How was the product installed? ❍ Professional Installer ❍ Self ❍ Other
7. Cost of product excluding sales tax? $
8. Cost to install product? $
9. Type of store where product was purchased? ❍ Hardware ❍ Propane Dealer ❍ Natural Gas/Utility Co. ❍ Home Center/Builder’s Supply

❍ Fireplace or Hearth Shop ❍ Farm Store ❍ Other

10. What motivated you to buy this product? ❍ Sudden Cold Weather ❍ Replace Older Model ❍ D.I.Y. Home Project

❍ Emergency Back-Up Heat ❍ Heater was on Sale ❍ Energy Savings/High Efficiency ❍ Construction Project ❍ Other

11. How did you learn about this product brand? ❍ Advertising ❍ Relative or Friend ❍ Store Display ❍ Other
12. Level of Education of Purchaser: ❍ Some High School ❍ Completed High School ❍ Completed College ❍ Completed Graduate School
13. Age of Purchaser: ❍ Under 20 ❍ 20 - 29 ❍ 30 - 39 ❍ 40 - 49 ❍ 50 - 59 ❍ 60 or Over
14. Buyer’s total annual household income: ❍ Under $15,000 ❍ $15,000 to $19,999 ❍ $20,000 to $34,999 ❍ $35,000 to $49,999

❍ $50,000 to $74,999 ❍ $75,000 to $99,999 ❍ $100,000 and Over

15. Store where product was purchased:
Name______________________________________
City_______________________ State: __________
16. In choosing this product, how important were the following:

Not Important Somewhat Important Very Important

Availability Price Brand Name Overall Quality Heat Output Made in USA Warranty Local Service Value for Price Prior Brand Experience Controls Location Thermostat, Remote, or Manual Operation Ease of Operation Special Features Salesperson’s Recommendation Friend/Relative’s Recommendation Portability Quiet Operation

❍

❍

❍

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 28 of the Desa Tech Gas Log Set (CGCFTN) user manual — TROUBLESHOOTING
Page 28 · click to enlarge
Page 28
Desa Tech Gas Log Set (CGCFTN) — TROUBLESHOOTING diagram (page 28)
Fig. 62

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004

Desa Tech Gas Log Set (CGCFTN) — TROUBLESHOOTING diagram (page 28)
Fig. 63

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Postage Required

Page 29 of the Desa Tech Gas Log Set (CGCFTN) user manual — CLEANING KIT - CCK (Not Shown)
Page 29 · click to enlarge
Page 29
Desa Tech Gas Log Set (CGCFTN) — TROUBLESHOOTING diagram (page 29)
Fig. 64

ACCESSORIES

Desa Tech Gas Log Set (CGCFTN) — ACCESSORIES diagram (page 29)
Fig. 65

Purchase these fireplace accessories from your local dealer or Parts Central (see page 26). If they cannot supply these accessories call DESA Heating Products’ Sales Department at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.

CABINET MANTEL WITH FULL HEARTH BASE

Stained Oak Veneer - GMC60F Unfinished Birch Veneer GMC61U The hardwood mantel and full hearth base feature fluted legs and crown molding. Available in medium stained oak, white lacquer finish, and unfinished hardwood, ready to stain or paint. Complete assembly instructions included. Three-sided brass trim kit included.

EQUIPMENT SHUTOFF VALVE - GA5010

For all models. Equipment shutoff valve with 1/8" NPT tap.

Desa Tech Gas Log Set (CGCFTN) — EQUIPMENT SHUTOFF VALVE - GA5010 diagram (page 29)
Fig. 66

BRASS TRIM KIT - GA6095

Optional four-sided brass trim kit for built-in installations. Provides a finished appearance covering rough edges of wall opening.

CORNER MANTEL WITH FULL HEARTH BASE

Stained Oak Veneer - GMC64F Unfinished Birch Veneer GMC63U

Space-saving mantel and full hearth base corner design offers classic styling. Available in stained oak or unfinished hardwood, ready to stain or paint. Complete assembly instructions included. Three-sided brass trim kit included.

THERMOSTATICALLYCONTROLLED BLOWER KIT - GA3450T

For all models. Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operating instructions included.

INFORMATION VIDEO - 108917-01

For all models. A care and maintenance video is available by calling 1-866-672-6040. You may also email your request to productsupport@desaint.com.

CLEANING KIT - CCK (Not Shown)

For all models. Your vent-free gas appliance requires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

Page 30 of the Desa Tech Gas Log Set (CGCFTN) user manual — NOT A UPC
Page 30 · click to enlarge
Page 30
Desa Tech Gas Log Set (CGCFTN) — TROUBLESHOOTING diagram (page 30)
Fig. 67

KEEP THIS WARRANTY

Desa Tech Gas Log Set (CGCFTN) — KEEP THIS WARRANTY diagram (page 30)
Fig. 68

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.

LIMITED WARRANTY VENT-FREE COMPACT FIREPLACE

DESA Heating Products warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this fireplace to proper operating condition and an allowance for labor when provided by a DESA Heating Products Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA Heating Products who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The fireplace MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA HEATING PRODUCTS’ LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA HEATING PRODUCTS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com

111044-01 Rev. D 09/03

NOT A UPC

111044-01D For more information, visit www.desatech.com For more information, visit www.desatech.com

111044 01

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Desa Tech Gas Log Set (CGCFTN)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Desa Tech Gas Log Set (CGCFTN)

Be the first to ask — other owners or our team will answer.

Original document

Desa Tech Gas Log Set (CGCFTN) manual PDF

30 pages·1.8 MB·Indoor Fireplace·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…